Note: The test data was only valid for the test sample(s). This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. IESNA LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch 5F, Building B, second phase of Chuangjian Industrial Area, YingRenShi community, Shiyan Street, Baoan District, Shenzhen. 518108 China Model: T5C Report Type: 6000 Hours Test Report Product Type: LED Package Test Engineer: Daniel Duan Report Number: RSZ150414502-10-6000 Test Date: 2015-04-20 to 2015-12-26 Report Date: 2016-01-07 Reviewed By: Jeanne Han /EE Manager Prepared By: Bay Area Compliance Laboratories Corp. (Dongguan). Pu Long Cun 69, Puxinghu Industrial Area, Tangxia Town, Dongguan, Guangdong, P.R.China. Tel: +86-0769-86858888 Fax:+86-0769-86858588

Upload: others

Post on 08-Jul-2020

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: IESNA LM-80-2008 · 2016-01-14 · Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch Model: T5C Report No. RSZ150414502-10-6000 Page 3 of 15 IESNA LM-80-08 Test Report 1 - GENERAL

Note: The test data was only valid for the test sample(s). This test report is prepared for the customer shown above and for the

device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance

Laboratories Corp. (Dongguan).

This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above

version 7.0.

IESNA LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES

MEASUREMENT AND TEST REPORT For

Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch 5F, Building B, second phase of Chuangjian Industrial Area, YingRenShi community, Shiyan Street,

Baoan District, Shenzhen. 518108 China

Model: T5C

Report Type:

6000 Hours Test Report

Product Type:

LED Package

Test Engineer: Daniel Duan

Report Number: RSZ150414502-10-6000

Test Date: 2015-04-20 to 2015-12-26

Report Date: 2016-01-07

Reviewed By: Jeanne Han /EE Manager

Prepared By:

Bay Area Compliance Laboratories Corp. (Dongguan).

Pu Long Cun 69, Puxinghu Industrial Area, Tangxia Town,

Dongguan, Guangdong, P.R.China.

Tel: +86-0769-86858888

Fax:+86-0769-86858588

Page 2: IESNA LM-80-2008 · 2016-01-14 · Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch Model: T5C Report No. RSZ150414502-10-6000 Page 3 of 15 IESNA LM-80-08 Test Report 1 - GENERAL

Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch Model: T5C

Report No. RSZ150414502-10-6000 Page 2 of 15 IESNA LM-80-08 Test Report

TABLE OF CONTENTS

1 - GENERAL INFORMATION.................................................................................................................................. 3

1.1 DESCRIPTION OF LED LIGHT SOURCES .................................................................................................................. 3 1.2 STANDARDS USED: ................................................................................................................................................. 4 1.3 TEST FACILITY ....................................................................................................................................................... 4 1.4 DESCRIPTION OF AUXILIARY EQUIPMENT .............................................................................................................. 4 1.5 OPERATING CYCLE................................................................................................................................................. 4 1.6 AMBIENT CONDITIONS ........................................................................................................................................... 5 1.7 PHOTOMETRY MEASUREMENT UNCERTAINTY ....................................................................................................... 5 1.8 SAMPLE SET ........................................................................................................................................................... 6

2 - SUMMARY OF TEST RESULT ............................................................................................................................ 7

3 - TEST DATA ............................................................................................................................................................. 8

3.1 DATA SET 1, 55°C, 200MA (LUMEN MAINTENANCE) ............................................................................................ 8 3.2 DATA SET 1, 55°C, 200MA (CHROMATICITY SHIFT) .............................................................................................. 9 3.3 DATA SET 2, 85°C, 200MA (LUMEN MAINTENANCE) .......................................................................................... 10 3.4 DATA SET 2, 85°C, 200MA (CHROMATICITY SHIFT) ............................................................................................ 11 3.5 DATA SET 3, 105°C, 200MA (LUMEN MAINTENANCE) ........................................................................................ 12 3.6 DATA SET 3, 105°C, 200MA (CHROMATICITY SHIFT) .......................................................................................... 13

ATTACHMENT A – EUT PHOTO ........................................................................................................................... 14

A.1 MECHANICAL DIMENSIONS (TA = 25°C) ............................................................................................................. 14 A.2 EUT PHOTO ........................................................................................................................................................ 14

ATTACHMENT B – FAMILY DECLARATION LETTER .................................................................................. 15

Page 3: IESNA LM-80-2008 · 2016-01-14 · Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch Model: T5C Report No. RSZ150414502-10-6000 Page 3 of 15 IESNA LM-80-08 Test Report 1 - GENERAL

Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch Model: T5C

Report No. RSZ150414502-10-6000 Page 3 of 15 IESNA LM-80-08 Test Report

1 - GENERAL INFORMATION

1.1 Description of LED Light Sources

Devices tested

Family products covered by this report:

According to ENERGY STAR® Program Guidance Regarding LED Package, LED Array and LED Module Lumen Maintenance Performance Data Supporting Qualification of Lighting Products, the following products can be covered by this report base on the declaration letter of manufacturer (see attachment B for more information). The information of these models shows that the covered products meet all section 3 item 7 requirements of ENERGY STAR® Program Guidance Regarding LED Package, LED Array and LED Module Lumen Maintenance Performance Data Supporting Qualification of Lighting Products (September 9, 2011)

Series Name Model Name CCT(K) Number of Dies Current(mA) Volt(v)

EMC5050 T5C30881*-** 3000 8 200 26

EMC5050 T5C27781*-** 2700 8 200 26

EMC5050 T5C27881*-** 2700 8 200 26

EMC5050 T5C27981*-** 2700 8 200 26

EMC5050 T5C30781*-** 3000 8 200 26

EMC5050 T5C30981*-** 3000 8 200 26

EMC5050 T5C35781*-** 3500 8 200 26

EMC5050 T5C35881*-** 3500 8 200 26

EMC5050 T5C35981*-** 3500 8 200 26

EMC5050 T5C40781*-** 4000 8 200 26

EMC5050 T5C40881*-** 4000 8 200 26

EMC5050 T5C40981*-** 4000 8 200 26

EMC5050 T5C45781*-** 4500 8 200 26

EMC5050 T5C45881*-** 4500 8 200 26

EMC5050 T5C45981*-** 4500 8 200 26

EMC5050 T5C50781*-** 5000 8 200 26

EMC5050 T5C50881*-** 5000 8 200 26

EMC5050 T5C50981*-** 5000 8 200 26

EMC5050 T5C57781*-** 5700 8 200 26

EMC5050 T5C57881*-** 5700 8 200 26

EMC5050 T5C57981*-** 5700 8 200 26

EMC5050 T5C61781*-** 6100 8 200 26

EMC5050 T5C61881*-** 6100 8 200 26

EMC5050 T5C61981*-** 6100 8 200 26

EMC5050 T5C65781*-** 6500 8 200 26

EMC5050 T5C65881*-** 6500 8 200 26

EMC5050 T5C65981*-** 6500 8 200 26

Part Number: T5C

Part Type: LED Package

Nominal CCT: 3000K

Forward Voltage: 24-28V

Page 4: IESNA LM-80-2008 · 2016-01-14 · Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch Model: T5C Report No. RSZ150414502-10-6000 Page 3 of 15 IESNA LM-80-08 Test Report 1 - GENERAL

Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch Model: T5C

Report No. RSZ150414502-10-6000 Page 4 of 15 IESNA LM-80-08 Test Report

Disclaimer:

The truthfulness and accuracy of all the technical information above for the covered LED products is

ensured by manufacturer of LED light source. Bay Area Compliance Laboratories Corp. (Dongguan) isn’t

responsible or gives any guarantees for the truthfulness of the technical information.

1.2 Standards Used:

IESNA LM-80-08: IES Approved Method for Measuring Lumen Maintenance of LED Light Sources.

ENERGY STAR® Program Guidance Regarding LED Package, LED Array and LED Module

Lumen Maintenance Performance Data Supporting Qualification of Lighting Products(This test

method was not accredited by IAS)

1.3 Test Facility

The testing facility used by Bay Area Compliance Laboratories Corp. (Dongguan). is located at Pu

Long Cun 69, Puxinghu Industrial Area, Tangxia Town, Dongguan, Guangdong, P.R.China.

1.4 Description of Auxiliary Equipment

Device Manufacture Model No Serial No Test Range Calibration

date Calibration

due date

Integral Sphere EVERFINE Diameter

0.3m 1011119

380-780nm, Diameter:0.3m,0-

1999Lumen 2015-03-25 2016-03-25

Programmable Test Power for LEDs

EVERFINE LED300E 1008002 15V/2000mA 2015-03-05 2016-03-05

High accuracy array spectroradiometer

EVERFINE HAAS-2000 1012016T 380-780nm 2015-03-25 2016-03-25

Standard Light Source EVERFINE D062 1011093 N/A 2015-08-05 2016-08-05

Precision digital stabilized DC power

supply EVERFINE WY605

G115987CJ7321114

300VA 2015-03-05 2016-03-05

Multilayer aging machine

BACL B2-270 20015 25℃~110℃ 2015-03-05 2016-03-05

Digital CC&CV DC Power Supply

EVERFINE WY5015 11060010 (50V/15A) 2015-03-05 2016-03-05

Digital CC&CV DC Power Supply

EVERFINE WY5015 11090008 (50/15A) 2015-07-08 2016-07-07

Digital CC&CV DC Power Supply

EVERFINE WY5015 11060002 (50V/15A) 2015-07-08 2016-07-07

1.5 Operating Cycle

Samples are driven with a constant direct current (DC)

Page 5: IESNA LM-80-2008 · 2016-01-14 · Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch Model: T5C Report No. RSZ150414502-10-6000 Page 3 of 15 IESNA LM-80-08 Test Report 1 - GENERAL

Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch Model: T5C

Report No. RSZ150414502-10-6000 Page 5 of 15 IESNA LM-80-08 Test Report

1.6 Ambient Conditions

For lumen maintenance test, samples were operated in thermal chambers with minimal ambient

airflow. For long term reliability test, the case temperature was controlled by mounting several

thermocouples on a sample reliability stress board at the designated thermal measurement point, as shown

in APPENDIX. The ambient temperature TA was measured by several thermocouples at a distance of 5

mm above the reliability test board. The relative humidity within chamber was less than 65%.

For photometry measurement, temperature was set to 25°C ± 2°C, RH <65%.

1.7 Photometry Measurement Uncertainty

The uncertainty of the light output measurements is U=1.59% (K=2), at the 95% confidence level.

The uncertainty of the correlated color temperature measurements is U=21K (K=2), at the 95% confidence

level. This calibration results traceable to the NATIONAL INSTITUTE OF METROLOGY (NIM).

Page 6: IESNA LM-80-2008 · 2016-01-14 · Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch Model: T5C Report No. RSZ150414502-10-6000 Page 3 of 15 IESNA LM-80-08 Test Report 1 - GENERAL

Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch Model: T5C

Report No. RSZ150414502-10-6000 Page 6 of 15 IESNA LM-80-08 Test Report

1.8 Sample Set

Sampling Method: LED samples for IESNA LM-80 testing consist of units built from a minimum of three manufacturing lots with each manufacturing lot built from different wafer lots built on non-consecutive days. These manufacturing lots are picked to represent a wide parametric distribution. Each Sample is soldered to all of the reliability stress boards for a given set of IESNA LM-80 tests. Sample Size: Total 66Pcs; Each Ts test condition 22Pcs The samples tested at TS 55°C, Ts 85°C and TS 105°C were received at 2015-04-14 and tested during 2015-04-20 to 2015-12-26. The samples were numbered from 1 to 22, 23 to 44 and 45 to 66

Data Set 1: 55°C, 200mA

Part Number: T5C

Number of Units: 22

Actual Case Temperature(TS): TS =53.6°C

Actual Ambient Temperature(TA): TA =52.2°C

Life Test Drive Current: IF = 200mA

Measurement Current: IF = 200mA

Data Set 2: 85°C,200mA

Part Number: T5C

Number of Units: 22

Actual Case Temperature(TS): TS =84.2°C

Actual Ambient Temperature(TA): TA =82.6°C

Life Test Drive Current: IF =200mA

Measurement Current: IF = 200mA

Data Set 3: 105°C, 200mA

Part Number: T5C

Number of Units: 22

Actual Case Temperature(TS): TS =104.1°C

Actual Ambient Temperature(TA): TA =103.2°C

Life Test Drive Current: IF = 200mA

Measurement Current: IF = 200mA

Page 7: IESNA LM-80-2008 · 2016-01-14 · Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch Model: T5C Report No. RSZ150414502-10-6000 Page 3 of 15 IESNA LM-80-08 Test Report 1 - GENERAL

Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch Model: T5C

Report No. RSZ150414502-10-6000 Page 7 of 15 IESNA LM-80-08 Test Report

2 - SUMMARY OF TEST RESULT

Data Set: Data Set 1, 55°C, 200mA

Number of Units: 22

Failures Observed: 0

Test Interval and Test Duration: 0h,1000h,2000h,3000h,4000h,5000h,6000h

Average. Lumen Maintenance at 6000 hours: 96.92%

Average Chromaticity Shift at 6000 hours (∆u’v’): 0.0020

Reported TM-21 L70 Lifetime: >36,000 hours

Data Set: Data Set 2, 85°C, 200mA

Number of Units: 22

Failures Observed: 0

Test Interval and Test Duration: 0h,1000h,2000h,3000h,4000h,5000h,6000h

Average. Lumen Maintenance at 6000 hours: 96.33%

Average Chromaticity Shift at 6000 hours(∆u’v’): 0.0023

Reported TM-21 L70 Lifetime: >36,000 hours

Data Set: Data Set 3, 105°C, 200mA

Number of Units: 22

Failures Observed: 0

Test Interval and Test Duration: 0h,1000h,2000h,3000h,4000h,5000h,6000h

Average. Lumen Maintenance at 6000 hours: 95.48%

Average Chromaticity Shift at 6000 hours(∆u’v’): 0.0024

Reported TM-21 L70 Lifetime: >36,000 hours

Page 8: IESNA LM-80-2008 · 2016-01-14 · Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch Model: T5C Report No. RSZ150414502-10-6000 Page 3 of 15 IESNA LM-80-08 Test Report 1 - GENERAL

Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch Model: T5C

Report No. RSZ150414502-10-6000 Page 8 of 15 IESNA LM-80-08 Test Report

3 - Test Data

3.1 Data Set 1, 55°C, 200mA (Lumen Maintenance)

No. VF(V) Φ(lm) Lumen Maintenance (%)

0hr(Initial) 1000hrs 2000hrs 3000hrs 4000hrs 5000hrs 6000hrs

1 25.92 630.4 99.21 98.86 98.41 97.76 97.27 97.08

2 26.25 650.3 98.94 98.77 98.59 98.37 97.42 96.97

3 26.16 648.8 99.21 99.18 99.11 98.38 98.06 97.63

4 26.47 640.9 99.14 98.85 98.08 97.04 96.77 96.63

5 26.19 638.1 99.14 98.82 98.14 97.38 97.09 96.72

6 26.05 641.3 99.20 99.06 98.35 97.97 96.99 96.55

7 26.34 636.7 98.93 98.51 98.30 97.68 97.19 96.80

8 26.27 645.8 99.24 98.84 98.58 97.86 97.51 97.38

9 26.22 644.8 99.40 99.12 98.71 98.60 97.98 97.64

10 26.15 635.3 98.77 98.73 98.24 97.75 96.95 96.76

11 26.14 639.0 99.17 98.92 98.23 97.48 96.90 96.54

12 26.12 607.8 98.96 98.21 97.96 97.22 96.78 96.33

13 25.86 627.6 99.09 98.66 98.12 97.55 96.75 96.22

14 26.06 625.6 99.38 99.26 98.90 98.31 97.55 97.15

15 26.17 643.6 99.18 98.87 98.71 98.07 97.14 96.92

16 26.24 627.3 98.80 98.37 97.85 96.83 96.33 96.14

17 26.25 632.9 99.37 98.70 98.53 98.09 97.14 96.93

18 26.28 631.3 99.02 98.56 98.26 97.54 97.20 96.71

19 26.09 651.5 99.22 98.77 98.30 97.76 97.59 97.18

20 26.13 636.2 99.76 99.07 98.84 98.77 98.02 97.74

21 26.25 636.4 99.31 99.01 98.65 98.51 98.05 97.42

22 25.99 634.1 99.10 98.63 98.42 98.23 97.40 96.81

Ave. 26.16 636.6 99.16 98.81 98.42 97.87 97.28 96.92

Med. 26.17 636.6 99.17 98.83 98.38 97.81 97.19 96.87

st dev 0.1374 9.7938 0.2177 0.2599 0.3172 0.5154 0.4691 0.4494

Min. 25.86 607.8 98.77 98.21 97.85 96.83 96.33 96.14

Max. 26.47 651.5 99.76 99.26 99.11 98.77 98.06 97.74

TM-21 Projection:

Test Duration: 6000 hours Failures Observed: 0

α: 4.762E-06 β: 0.997

Calculated L70: 74,000 hours Reported L70: >36,000 hours

Page 9: IESNA LM-80-2008 · 2016-01-14 · Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch Model: T5C Report No. RSZ150414502-10-6000 Page 3 of 15 IESNA LM-80-08 Test Report 1 - GENERAL

Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch Model: T5C

Report No. RSZ150414502-10-6000 Page 9 of 15 IESNA LM-80-08 Test Report

3.2 Data Set 1, 55°C, 200mA (Chromaticity Shift)

No. u’ v’ CCT(K) Chromaticity Shift (∆u’v’)

0hr(Initial) 1000hrs 2000hrs 3000hrs 4000hrs 5000hrs 6000hrs

1 0.2481 0.5184 3083 0.0007 0.0009 0.0012 0.0015 0.0015 0.0017

2 0.2487 0.5198 3057 0.0006 0.0008 0.0009 0.0006 0.0016 0.0020

3 0.2478 0.5186 3089 0.0006 0.0009 0.0009 0.0021 0.0019 0.0021

4 0.2475 0.5189 3094 0.0007 0.0010 0.0010 0.0022 0.0021 0.0023

5 0.2481 0.5183 3082 0.0004 0.0008 0.0010 0.0018 0.0020 0.0022

6 0.2474 0.5187 3100 0.0005 0.0009 0.0012 0.0022 0.0027 0.0029

7 0.2483 0.5177 3083 0.0005 0.0010 0.0012 0.0016 0.0019 0.0024

8 0.2481 0.5193 3078 0.0006 0.0011 0.0012 0.0011 0.0016 0.0019

9 0.2473 0.5156 3125 0.0006 0.0011 0.0012 0.0013 0.0016 0.0018

10 0.2477 0.5181 3096 0.0007 0.0010 0.0012 0.0014 0.0017 0.0020

11 0.2477 0.5173 3101 0.0007 0.0009 0.0012 0.0009 0.0011 0.0014

12 0.2480 0.5183 3085 0.0002 0.0003 0.0004 0.0014 0.0018 0.0024

13 0.2479 0.5177 3093 0.0005 0.0008 0.0009 0.0009 0.0009 0.0012

14 0.2473 0.5175 3109 0.0008 0.0009 0.0010 0.0009 0.0005 0.0011

15 0.2478 0.5181 3091 0.0008 0.0009 0.0010 0.0016 0.0016 0.0012

16 0.2487 0.5185 3065 0.0010 0.0012 0.0013 0.0019 0.0018 0.0024

17 0.2481 0.5188 3080 0.0011 0.0014 0.0013 0.0017 0.0017 0.0024

18 0.2463 0.5158 3149 0.0011 0.0013 0.0014 0.0016 0.0017 0.0015

19 0.2479 0.5181 3091 0.0011 0.0016 0.0017 0.0013 0.0010 0.0016

20 0.2481 0.5190 3078 0.0007 0.0011 0.0013 0.0022 0.0030 0.0027

21 0.2486 0.5188 3068 0.0007 0.0012 0.0014 0.0012 0.0019 0.0028

22 0.2474 0.5178 3104 0.0006 0.0012 0.0014 0.0008 0.0006 0.0015

Ave. 0.2479 0.5181 3091 0.0007 0.0010 0.0011 0.0015 0.0017 0.0020

Med. 0.2479 0.5183 3090 0.0007 0.0010 0.0012 0.0014 0.0017 0.0020

st dev 0.0005 0.0010 19.8817 0.0002 0.0003 0.0003 0.0005 0.0006 0.0005

Min. 0.2463 0.5156 3057 0.0002 0.0003 0.0004 0.0006 0.0005 0.0011

Max. 0.2487 0.5198 3149 0.0011 0.0016 0.0017 0.0022 0.0030 0.0029

0.0000

0.0005

0.0010

0.0015

0.0020

0.0025

0.0030

0.0035

0.0040

70%

75%

80%

85%

90%

95%

100%

105%

110%

0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000

Ch

rom

aticity Shift (D

u'v')

% L

um

ino

us

Flu

x

Time (hours)

Flux

∆u'v'

Page 10: IESNA LM-80-2008 · 2016-01-14 · Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch Model: T5C Report No. RSZ150414502-10-6000 Page 3 of 15 IESNA LM-80-08 Test Report 1 - GENERAL

Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch Model: T5C

Report No. RSZ150414502-10-6000 Page 10 of 15 IESNA LM-80-08 Test Report

3.3 Data Set 2, 85°C, 200mA (Lumen Maintenance)

No. VF(V) Φ(lm) Lumen Maintenance (%)

0hr(Initial) 1000hrs 2000hrs 3000hrs 4000hrs 5000hrs 6000hrs

23 26.04 643.5 98.63 98.14 97.95 97.16 96.29 95.85

24 25.93 632.3 98.92 98.50 97.91 96.74 95.94 95.68

25 26.44 640.0 99.16 98.66 98.09 97.16 96.66 95.89

26 25.99 647.6 99.09 98.36 97.82 97.16 96.14 95.92

27 26.45 633.6 98.99 98.48 98.22 97.35 97.14 96.84

28 26.34 641.7 98.66 98.24 97.48 96.70 95.75 95.28

29 26.24 649.2 98.86 98.55 97.66 96.78 95.83 95.07

30 26.03 641.7 98.74 98.52 97.87 97.07 96.59 96.57

31 25.87 648.2 98.83 98.58 98.15 97.55 96.65 96.54

32 26.37 658.1 98.63 97.92 97.33 96.47 96.08 95.49

33 26.04 637.3 98.95 98.42 97.80 97.38 96.56 96.42

34 25.89 648.5 98.83 98.23 98.20 97.83 97.18 96.95

35 26.02 651.4 99.25 98.53 98.33 97.97 97.18 96.71

36 26.01 649.0 99.85 99.32 98.67 98.14 97.35 97.06

37 26.16 656.6 99.03 98.58 99.21 98.48 98.00 97.56

38 26.40 636.1 99.18 98.70 98.16 97.44 96.75 96.45

39 26.09 648.5 99.34 98.81 98.43 97.50 96.79 96.19

40 26.03 642.8 99.30 99.22 98.46 97.96 97.43 97.12

41 26.16 640.4 98.86 98.81 98.16 97.64 97.41 97.19

42 26.28 634.7 98.93 98.52 97.48 96.86 96.27 95.64

43 26.20 646.0 98.62 98.34 97.49 96.55 96.21 95.98

44 26.15 652.6 99.31 99.07 98.39 97.61 97.59 96.87

Ave. 26.14 644.5 99.00 98.57 98.06 97.34 96.72 96.33

Med. 26.12 644.8 98.94 98.52 98.12 97.36 96.65 96.43

st dev 0.1774 7.1951 0.2970 0.3350 0.4440 0.5369 0.6255 0.6785

Min. 25.87 632.3 98.62 97.92 97.33 96.47 95.75 95.07

Max. 26.45 658.1 99.85 99.32 99.21 98.48 98.00 97.56

TM-21 Projection:

Test Duration: 6000 hours Failures Observed: 0

α: 5.740E-06 β: 0.996

Calculated L70: 62,000 hours Reported L70: >36,000 hours

Page 11: IESNA LM-80-2008 · 2016-01-14 · Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch Model: T5C Report No. RSZ150414502-10-6000 Page 3 of 15 IESNA LM-80-08 Test Report 1 - GENERAL

Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch Model: T5C

Report No. RSZ150414502-10-6000 Page 11 of 15 IESNA LM-80-08 Test Report

3.4 Data Set 2, 85°C, 200mA (Chromaticity Shift)

No. u’ v’ CCT(K) Chromaticity Shift (∆u’v’)

0hr(Initial) 1000hrs 2000hrs 3000hrs 4000hrs 5000hrs 6000hrs

23 0.2484 0.5186 3073 0.0008 0.0013 0.0014 0.0018 0.0023 0.0021

24 0.2478 0.5183 3090 0.0008 0.0013 0.0014 0.0017 0.0019 0.0014

25 0.2476 0.5184 3096 0.0007 0.0012 0.0017 0.0030 0.0042 0.0025

26 0.2482 0.5193 3073 0.0008 0.0012 0.0015 0.0013 0.0022 0.0035

27 0.2480 0.5181 3086 0.0007 0.0011 0.0014 0.0011 0.0004 0.0009

28 0.2486 0.5193 3064 0.0012 0.0013 0.0017 0.0026 0.0019 0.0028

29 0.2486 0.5199 3059 0.0018 0.0023 0.0026 0.0036 0.0028 0.0037

30 0.2484 0.5199 3064 0.0007 0.0014 0.0017 0.0025 0.0018 0.0019

31 0.2487 0.5193 3061 0.0007 0.0009 0.0015 0.0021 0.0021 0.0023

32 0.2484 0.5189 3072 0.0010 0.0013 0.0018 0.0015 0.0022 0.0017

33 0.2480 0.5180 3088 0.0007 0.0011 0.0017 0.0023 0.0024 0.0021

34 0.2482 0.5185 3080 0.0010 0.0012 0.0019 0.0024 0.0026 0.0023

35 0.2479 0.5191 3082 0.0008 0.0012 0.0018 0.0023 0.0027 0.0029

36 0.2473 0.5188 3101 0.0002 0.0008 0.0014 0.0014 0.0022 0.0025

37 0.2489 0.5189 3059 0.0007 0.0011 0.0016 0.0016 0.0006 0.0008

38 0.2484 0.5186 3072 0.0006 0.0012 0.0017 0.0019 0.0027 0.0017

39 0.2477 0.5191 3089 0.0007 0.0011 0.0017 0.0019 0.0017 0.0025

40 0.2479 0.5192 3082 0.0006 0.0009 0.0015 0.0028 0.0025 0.0020

41 0.2472 0.5168 3118 0.0006 0.0011 0.0017 0.0019 0.0027 0.0026

42 0.2477 0.5188 3090 0.0005 0.0010 0.0015 0.0018 0.0026 0.0026

43 0.2486 0.5188 3066 0.0006 0.0009 0.0015 0.0018 0.0028 0.0024

44 0.2482 0.5184 3081 0.0007 0.0012 0.0017 0.0011 0.0021 0.0025

Ave. 0.2481 0.5188 3079 0.0008 0.0012 0.0017 0.0020 0.0022 0.0023

Med. 0.2482 0.5188 3081 0.0007 0.0012 0.0017 0.0019 0.0023 0.0024

st dev 0.0005 0.0007 14.9588 0.0003 0.0003 0.0003 0.0006 0.0008 0.0007

Min. 0.2472 0.5168 3059 0.0002 0.0008 0.0014 0.0011 0.0004 0.0008

Max. 0.2489 0.5199 3118 0.0018 0.0023 0.0026 0.0036 0.0042 0.0037

0.0000

0.0005

0.0010

0.0015

0.0020

0.0025

0.0030

0.0035

0.0040

70%

75%

80%

85%

90%

95%

100%

105%

110%

0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000

Ch

rom

aticity Shift (D

u'v')

% L

um

ino

us

Flu

x

Time (hours)

Flux

∆u'v'

Page 12: IESNA LM-80-2008 · 2016-01-14 · Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch Model: T5C Report No. RSZ150414502-10-6000 Page 3 of 15 IESNA LM-80-08 Test Report 1 - GENERAL

Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch Model: T5C

Report No. RSZ150414502-10-6000 Page 12 of 15 IESNA LM-80-08 Test Report

3.5 Data Set 3, 105°C, 200mA (Lumen Maintenance)

No. VF(V) Φ(lm) Lumen Maintenance (%)

0hr(Initial) 1000hrs 2000hrs 3000hrs 4000hrs 5000hrs 6000hrs

45 26.31 639.0 99.01 98.48 97.79 96.73 95.92 95.31

46 26.17 645.4 98.99 98.22 97.57 97.07 96.16 95.32

47 26.05 648.0 99.15 98.67 98.02 97.13 96.67 96.11

48 26.20 639.6 98.95 98.55 97.72 96.89 95.95 95.29

49 26.24 648.5 99.03 98.57 97.67 96.75 96.31 95.81

50 26.08 648.2 99.35 98.72 98.21 97.42 97.16 96.84

51 26.41 635.7 98.87 98.54 97.84 97.06 96.07 95.33

52 26.29 633.8 98.97 98.37 98.01 97.18 96.45 95.55

53 26.07 641.5 99.08 98.07 97.68 95.88 94.86 94.50

54 26.35 637.9 99.03 98.21 97.52 97.02 95.85 95.69

55 25.99 639.0 98.89 98.47 97.98 96.85 96.48 96.06

56 26.18 639.4 99.12 98.20 97.79 96.67 95.93 95.87

57 26.32 632.3 99.04 97.96 97.31 96.28 95.40 95.14

58 26.26 643.2 98.63 97.89 97.25 96.10 95.60 95.18

59 26.26 632.8 99.05 98.44 97.49 96.78 95.97 95.73

60 26.30 638.0 99.17 98.43 97.38 96.46 95.47 95.25

61 26.20 636.0 99.09 98.52 97.91 96.70 96.35 96.05

62 26.24 636.8 98.90 98.65 97.71 96.69 95.74 94.60

63 25.97 641.9 98.91 98.33 97.55 96.73 96.15 95.45

64 25.91 632.0 99.22 98.28 97.31 96.11 95.71 94.97

65 26.48 636.3 98.54 97.64 96.83 96.20 96.18 95.29

66 26.18 644.5 98.63 98.03 97.15 97.01 96.25 95.25

Ave. 26.20 639.5 98.98 98.33 97.62 96.71 96.03 95.48

Med. 26.22 639.0 99.02 98.40 97.67 96.74 96.02 95.32

st dev 0.1442 5.1046 0.1938 0.2787 0.3303 0.3981 0.4818 0.5227

Min. 25.91 632.0 98.54 97.64 96.83 95.88 94.86 94.50

Max. 26.48 648.5 99.35 98.72 98.21 97.42 97.16 96.84

TM-21 Projection:

Test Duration: 6000 hours Failures Observed: 0

α: 7.439E-06 β: 0.997

Calculated L70: 48,000 hours Reported L70: >36,000 hours

Page 13: IESNA LM-80-2008 · 2016-01-14 · Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch Model: T5C Report No. RSZ150414502-10-6000 Page 3 of 15 IESNA LM-80-08 Test Report 1 - GENERAL

Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch Model: T5C

Report No. RSZ150414502-10-6000 Page 13 of 15 IESNA LM-80-08 Test Report

3.6 Data Set 3, 105°C, 200mA (Chromaticity Shift)

No. u’ v’ CCT(K) Chromaticity Shift (∆u’v’)

0hr(Initial) 1000hrs 2000hrs 3000hrs 4000hrs 5000hrs 6000hrs

45 0.2481 0.5185 3081 0.0008 0.0010 0.0017 0.0022 0.0023 0.0026

46 0.2486 0.5190 3066 0.0009 0.0013 0.0019 0.0012 0.0023 0.0029

47 0.2476 0.5196 3088 0.0006 0.0011 0.0017 0.0030 0.0022 0.0019

48 0.2481 0.5183 3082 0.0006 0.0011 0.0018 0.0015 0.0013 0.0014

49 0.2482 0.5196 3073 0.0006 0.0011 0.0018 0.0031 0.0016 0.0015

50 0.2473 0.5192 3097 0.0006 0.0011 0.0017 0.0023 0.0011 0.0028

51 0.2483 0.5187 3075 0.0008 0.0010 0.0017 0.0022 0.0020 0.0019

52 0.2485 0.5187 3070 0.0006 0.0009 0.0016 0.0006 0.0009 0.0018

53 0.2482 0.5186 3079 0.0008 0.0011 0.0017 0.0028 0.0028 0.0024

54 0.2460 0.5162 3155 0.0008 0.0011 0.0017 0.0006 0.0006 0.0011

55 0.2480 0.5189 3080 0.0010 0.0012 0.0023 0.0035 0.0026 0.0017

56 0.2482 0.5182 3081 0.0002 0.0009 0.0004 0.0005 0.0008 0.0014

57 0.2481 0.5180 3086 0.0001 0.0011 0.0013 0.0031 0.0032 0.0030

58 0.2487 0.5184 3068 0.0009 0.0013 0.0013 0.0027 0.0022 0.0031

59 0.2475 0.5181 3100 0.0008 0.0009 0.0011 0.0021 0.0029 0.0036

60 0.2475 0.5189 3093 0.0006 0.0011 0.0011 0.0021 0.0032 0.0024

61 0.2471 0.5180 3110 0.0006 0.0011 0.0013 0.0018 0.0025 0.0016

62 0.2479 0.5183 3089 0.0007 0.0011 0.0013 0.0020 0.0031 0.0026

63 0.2478 0.5191 3084 0.0006 0.0010 0.0011 0.0013 0.0021 0.0021

64 0.2483 0.5180 3079 0.0006 0.0010 0.0012 0.0019 0.0030 0.0033

65 0.2484 0.5196 3066 0.0008 0.0012 0.0012 0.0018 0.0023 0.0033

66 0.2483 0.5193 3071 0.0007 0.0013 0.0014 0.0024 0.0035 0.0046

Ave. 0.2479 0.5186 3085 0.0007 0.0011 0.0015 0.0020 0.0022 0.0024

Med. 0.2481 0.5187 3081 0.0007 0.0011 0.0015 0.0021 0.0023 0.0024

st dev 0.0006 0.0008 19.2707 0.0002 0.0001 0.0004 0.0008 0.0008 0.0009

Min. 0.2460 0.5162 3066 0.0001 0.0009 0.0004 0.0005 0.0006 0.0011

Max. 0.2487 0.5196 3155 0.0010 0.0013 0.0023 0.0035 0.0035 0.0046

0.0000

0.0005

0.0010

0.0015

0.0020

0.0025

0.0030

0.0035

0.0040

70%

75%

80%

85%

90%

95%

100%

105%

110%

0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000

Ch

rom

aticity Shift (D

u'v')

% L

um

ino

us

Flu

x

Time (hours)

Flux

∆u'v'

Page 14: IESNA LM-80-2008 · 2016-01-14 · Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch Model: T5C Report No. RSZ150414502-10-6000 Page 3 of 15 IESNA LM-80-08 Test Report 1 - GENERAL

Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch Model: T5C

Report No. RSZ150414502-10-6000 Page 14 of 15 IESNA LM-80-08 Test Report

Attachment A – EUT PHOTO

A.1 Mechanical Dimensions (Ta = 25°C)

All dimensions are in millimeter

A.2 EUT Photo

TMPLED

Page 15: IESNA LM-80-2008 · 2016-01-14 · Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch Model: T5C Report No. RSZ150414502-10-6000 Page 3 of 15 IESNA LM-80-08 Test Report 1 - GENERAL

Fujian Lightning Optoelectronic Co.,Ltd.Shenzhen Branch Model: T5C

Report No. RSZ150414502-10-6000 Page 15 of 15 IESNA LM-80-08 Test Report

Attachment B – Family declaration Letter