ig balance
DESCRIPTION
IG balanceTRANSCRIPT
O2 = 2.5 %CO2 = 1.4 %CO = 0.3 * CO2 = 0.42 %N2 = rest = 95.7 %Air In = 140 KNm3/HOff gas gen = 117.06 KNm3/H
UsersC-1712 Present C-1711 air flow = 131KN3/H, so theoretical power required = 18MW/H
C-1713 steam consumption = 48T/H ( + 0.84ata), so power recovery = 8.2MW/HPresent AX711 = 1.8MW/HSo, C-1712 power recovery = 18 - ( 8.2 + 1.8 ) = 8MW/H
C-1712 112 KNm3/HInert gas ( D + W ) = 5.06 KNm3/H
IGD IGWName Flow Name Flow
CTA
FLS 201 0FLS 706 0FLS 703 0FLS 705 0PC735 0FLS 702 0J-1736 0FLS 704 0C-1751 discharge 0N-1745 120FLS 707 0M-1741A 10M-1741B 10FLS 708 0M-2273 350FLS 271 0
PTA
FLS 801 0 Pneumatic 3000FLS 802 0 M-1873A 1000FLS 804 0 M-1873B 1000FLS 805 0C-1851 discharge 0
F-1841 1400
FLS 808 0M-1841A 10M-1841B 10M-1841C 10FLS 806 0Sealings 100
Correspondingly, OFF gas flowrate = 112KNm3/H.
not same time use
remain IG = 5000 - sum(IGD above {600}) - sum(IGW{4000}) = 1400
C-1712
VENT
D-1738
PC731
D-1781
PC712
PC781
IGW
IGD
D-1782D-1731
Item Conc FlowPSA purge 5% 50 Nm3/HIG 0.42% x Nm3/H
Final gas <1% x + 50 Nm3/H
Balance equation(50 * 5) + (x * 0.41) = [1 * (x+50)]
x = 350Nm3/H
So flowmeter selection range = 0 to 500Nm3/H
IGD