O2 = 2.5 % CO2 = 1.4 % CO = 0.3 * CO2 = 0.42 % N2 = rest = 95.7 % Air In = 140 KNm3/H Off gas gen = 117.06 KNm3/H Users C-1712 Present C-1711 air flow = 131KN3/H, so theoretical power required = 18MW/H C-1713 steam consumption = 48T/H ( + 0.84ata), so power recovery = 8.2MW/H Present AX711 = 1.8MW/H So, C-1712 power recovery = 18 - ( 8.2 + 1.8 ) = 8MW/H C-1712 112 KNm3/H Inert gas ( D + W ) = 5.06 KNm3/H IGD IGW Name Flow Name Flow CTA FLS 201 0 FLS 706 0 FLS 703 0 FLS 705 0 PC735 0 FLS 702 0 J-1736 0 FLS 704 0 C-1751 discharge 0 N-1745 120 FLS 707 0 M-1741A 10 M-1741B 10 FLS 708 0 M-2273 350 FLS 271 0 PTA FLS 801 0 Pneumatic 3000 FLS 802 0 M-1873A 1000 FLS 804 0 M-1873B 1000 FLS 805 0 C-1851 discharge 0 F-1841 1400 FLS 808 0 M-1841A 10 M-1841B 10 M-1841C 10 FLS 806 0 Sealings 100 Correspondingly, OFF gas flowrate = 112KNm3/H. not same time use remain IG = 5000 - sum(IGD above {600}) - sum(IGW{4000}) = 1400 C-1712 VENT D-1738 PC731 D-1781 PC712 PC781 IGW IGD D-1782 D-1731

Upload: vikas-nigam

Post on 08-Jul-2016

214 views

Category:

Documents


0 download

DESCRIPTION

IG balance

TRANSCRIPT

Page 1: IG Balance

O2 = 2.5 %CO2 = 1.4 %CO = 0.3 * CO2 = 0.42 %N2 = rest = 95.7 %Air In = 140 KNm3/HOff gas gen = 117.06 KNm3/H

UsersC-1712 Present C-1711 air flow = 131KN3/H, so theoretical power required = 18MW/H

C-1713 steam consumption = 48T/H ( + 0.84ata), so power recovery = 8.2MW/HPresent AX711 = 1.8MW/HSo, C-1712 power recovery = 18 - ( 8.2 + 1.8 ) = 8MW/H

C-1712 112 KNm3/HInert gas ( D + W ) = 5.06 KNm3/H

IGD IGWName Flow Name Flow

CTA

FLS 201 0FLS 706 0FLS 703 0FLS 705 0PC735 0FLS 702 0J-1736 0FLS 704 0C-1751 discharge 0N-1745 120FLS 707 0M-1741A 10M-1741B 10FLS 708 0M-2273 350FLS 271 0

PTA

FLS 801 0 Pneumatic 3000FLS 802 0 M-1873A 1000FLS 804 0 M-1873B 1000FLS 805 0C-1851 discharge 0

F-1841 1400

FLS 808 0M-1841A 10M-1841B 10M-1841C 10FLS 806 0Sealings 100

Correspondingly, OFF gas flowrate = 112KNm3/H.

not same time use

remain IG = 5000 - sum(IGD above {600}) - sum(IGW{4000}) = 1400

C-1712

VENT

D-1738

PC731

D-1781

PC712

PC781

IGW

IGD

D-1782D-1731

Page 2: IG Balance

Item Conc FlowPSA purge 5% 50 Nm3/HIG 0.42% x Nm3/H

Final gas <1% x + 50 Nm3/H

Balance equation(50 * 5) + (x * 0.41) = [1 * (x+50)]

x = 350Nm3/H

So flowmeter selection range = 0 to 500Nm3/H

IGD