SPECIFIERS GUIDE TO OUR RANGE OF LINTELS
LINTEL GUIDE
BETTER BYDESIGN
-
8/9/2019 IG intels brochure
2/88
BBA Certification
National Building
Specification Approved
National House
Building Council
British Standards Institution
ISO 9001 & ISO 14001
RIBA CPD
Approved
Investors in People
Accreditation
CERTIFICATE No 05/4192
Home Builders
Federation
Builders Merchants
Federation
Building Research
Establishment
IG produce the UKslargest range of steel lintelsbacked by industry leadingtechnical support andex-stock delivery service.
BETTER BYDESIGN
-
8/9/2019 IG intels brochure
3/88
Steel Lintel Guide
CONTENTS PAGE
Innovation, Quality & Service 04
Lintel Performance 08
Material Specification 09
Specification Clauses 10
Installation Guide 12
Selecting the Correct Lintel 14
Lintel Range Index 16
Hi-Therm Lintel 18
Standard Cavity Wall Lintels 20
Wide Inner Leaf Cavity Wall Lintels 32
Wide Outer Leaf Cavity Wall Lintels 50
Eaves Lintels 64
Solid Wall & Box Lintels 66
Timber Frame & Single Leaf Lintels 72
Extended Range 80
Stainless Steel Range 84
www.iglintels.com
-
8/9/2019 IG intels brochure
4/88
4 LINTEL GUIDE
Innovation
Through continual innovation the IG range nowprovides lintel solutions for every structuralrequirement, compliant with the latest regulations.
Founded in 1958, IG Lintels is a divisionof Europes largest manufacturer ofsteel lintels and masonry supportsystems. IG Lintels design, manufactureand supply high quality steel lintelsthroughout Europe.
IG invented the original open backlintel in 1967, which quickly becamethe industry standard. Our lintels are
engineered to be the most structurally
and thermally efficient lintels available.Continual development ensures theyare widely specified for use throughoutEurope on commercial, industrial,residential and institutional projects.
In 2011 IG introduced Hi-Therm, aunique product designed to exceedthe thermal requirements of futurebuilding regulations.
-
8/9/2019 IG intels brochure
5/88
www.iglintels.com
5BETTER BYDESIGN
THERMAL PERFORMANCE
Building regulations require that lintelsshould be assessed for their effect onthe thermal performance of a building.A lintels thermal performance is expressedin terms of Psi Values () i.e. linear thermaltransmittance.
STANDARD IG LINTELAll IG standard lintels satisfy the thermalperformance requirements of England andWales Part L of the building regulations,Northern Irelands Part F and ScotlandsTechnical Handbook, section 6.
Our standard L1 range has Psi valuesranging from 0.2 to 0.3 W/m.k. The exactfigure of your Psi value depends upon thewall construction the lintel is built into. Formore detailed information on Psi valuesapplicable to your wall construction or formore information on accredited constructiondetails please contact IGs technical team.
STANDARD IG LINTELwith patented Thermal Break Plate
HI-THERM IG LINTELpatented Galvanised Steel/GRP Lintel
HI-THERM IG LINTELIGs Hi-Therm Lintel is a combination of GRPand Galvanised Steel. When combined thesetwo materials form the ultimate in lintel design- Psi 0.05 W/m.K
Testing of IGs Hi-Therm Lintel was carried out bythe BRE (Building Research Establishment) usingPhysibels thermal analysis software TRISCO whichcomplies with BS EN ISO10211-1. The modellingfollows the requirements of the BRE conventionsdocument BR497.
OUTSTANDING ADVANTAGES
Outperformsall other cavity wall lintels forthermal performance. GRP has very lowthermal conductivity which practically eliminatescold bridging.
Outperformsstainless steel and galvanisedsteel for corrosion resistance. The GRP outerflange, quite simply, will never corrode.
Outperformsstainless steel in price. GRP ismore competitively priced than stainless steel.
DPC is not normally required. The GRP outerflange does not require the installation of aseparate Damp Proof Course/Cavity Tray.
(Areas of severe exposure will require a separateDPC. See BS 8104 zones 3+4).
Hi-Therm has achieved a 1 hour fire resistance testas carried out by Exova Warringtonfire utilising theheating conditions of BS EN 1363-1 1999.
THERMALPERFORMANCETESTING
Galvanised Steel
GRP
LINTEL HOTLINE
01633 486486
ColdOuter Leaf
WarmInner Leaf
ThermalBreak Plate
Thermal Breaki.e. no contact
10% Contact Only
ColdOuter Leaf
WarmInner Leaf
ThermalBreak Plate
Insulation fixed inplace by IG
-
8/9/2019 IG intels brochure
6/88
6 LINTEL GUIDE
SPECIAL LINTELS
IG offer a complete customdesign service to ensure yourproject has the best lintel forthe job. Our technical expertiseis renowned for delivering
solutions with total efficiency.
STANDARD LINTELS
IG produce a wide range ofstandard galvanised steeland stainless steel lintels.All IG standard lintels satisfythe Thermal Performance
requirements of all UKbuilding regulations.
Support
RANGE
With the largest range and more support, IG has over 50 yearsexperience in delivering effective service and solutions.
HI-THERM
IG has redefined lintelperformance with Hi-Therm,designed to exceed the thermalrequirements in forthcomingbuilding regulations. Hi-Therm
is supported by an advancedtechnical service package.
CAVITY TRAYS
The IG Cavity Tray presentsa lightweight, simple toinstall and long-lastingsolution to preventingdampness from penetrating
below the roof line.
BRICKWORKFEATURE LINTELS
IG Brickwork FeatureLintels are a one pieceprefabricated unit,manufactured bespoke
to order, achieving eventhe most challengingarchitectural designs.
MASONRY SUPPORT& WINDPOST SYSTEMS
IG continues to set the standardfor masonry support andwindpost systems for a range ofbuilding frame configurations.
The innovative Qwik Fix angleprovides a versatile solution whenmasonry support is required.
-
8/9/2019 IG intels brochure
7/88
www.iglintels.com
7BETTER BYDESIGN
TECHNICAL SUPPORT
IG provides comprehensive technical support forall products. Our free scheduling and specificationservice offers fast turnaround on standard lintels,masonry support and windpost systems.
IG leads the market with a bespoke designservice for special lintels and brickwork featurelintels, including onsite measurement andtechnical assistance.
Our in-house experts use the latest thermalmodelling software to advise clients on theoptimum lintel solution for compliance withand beyond the latest building regulations.
By contacting our engineers at an early stageof your design process, you will potentially gainsignificantly more design flexibility for theoverall project. Please send your drawings to:[email protected]
Please refer to our Fax Back Forms for speciallintel requirements. Detailed measuring adviceand Fax Back Enquiry Forms are available fordownload at: www.iglintels.com/technical.
FASTRACK DATABASE FOR CADThe IG Fastrack Database is accessible from theIG website and provides downloads of CAD filesfor a selection of IG Steel Lintels.
NBS PLUS
IG provides specification details via RIBA NBS Plus,accessible accessible via our website or via RIBAfor NBS subscribers.
DELIVERYIGs fast, efficient delivery service is renownedthroughout the construction industry. Ourlogistics solution is recognised by our customersfor superior supply chain management.
IG continues to provide the largest range oflintels available, with the shortest lead timesin the industry. We have invested in largestock inventories at our three manufacturingand distribution centres reassuring our customersthat all our standard lintels are instantly availableupon request.
IG has revolutionised the steel lintel industryby manufacturing and delivering speciallintels with lead-times historically associatedwith ex-stock items.
IG products are available through anational network of merchant suppliers.For information of merchant suppliers
in your area please visit our website at:www.iglintels.com/merchants
IGgives a hassle free service from enquiry
stage through to delivery on site. You canrelax in the knowledge that your order is inthe hands of experts.
-
8/9/2019 IG intels brochure
8/88
8 LINTEL GUIDE
Standard Lintel
PerformanceFIRE PERFORMANCE
IG lintelshave been subjected to a fire test(ref: WARRES No. 101263) in accordance withBS 476:Part20: 1987, at Exova Warringtonfireand achieved a one hour fire performance.
If longer fire rating figures are required they canbe achieved by applying a proprietary fire boardto the soffit of the inner flange of the steel lintel.Please contact our technical team if furtherfire rating provisions are required.
CORROSION RESISTANCE
IGs standard range of lintels are manufactured fromhigh quality grade pre-galvanised mild steel with azinc coating of 600g/m (including both sides).
The hot dipped, pre-galvanising process is carriedout at the mill to ensure a more consistent quality ofzinc coating. This guarantees a more effective anti-corrosive system. Furthermore pre-galvanised lintelsare much more environmentally friendly than postgalvanised lintels with a lower carbon footprint.
STRUCTURAL PERFORMANCE
The IG Lintelrange has safe working loads asdetailed in each applicable loading table in our LintelGuidebrochure. The structural performance figureswithin each table have been ascertained by testingin accordance with the requirements of standardsBS 5977 Part 2 1983 and BS EN 845-2:2003.
The figures take into account the different loadingarrangements which are common to traditionalcavity wall construction.
Differential Total UDL kN 3:1Up to 75% loading on the inner leaf.
Differential Total UDL kN 19:1Up to 95% loading on the inner leaf.
LINTEL LOAD TABLES
For full details of load tables specific to your linteltype please see Lintel Range & Loading Tablespages 19-73.
Lintel types: L1/S 50, L1/S 75, L1/S 100, L1/HD 50,L1/HD 75, L1/HD 100, L1/S 50 WIL 215, L1/S 75
WIL 215, L1/S 100 WIL 215, L1/S 110, L1/S 130,L1/S 150, L10, L7, L11, L8/RB, L1/TJ, INT 100, L9,IBEAM, L1/E 50, L1/E 100, L5, L6 have been testedas a composite unit with surrounding masonry, builtin accordance with BS EN 1996-2:2006.
LINTEL LIFE SPAN
The IG lintel range complies with the technicalrequirements of the BLP (Building Life Plans)regarding the durability data of mild steel,cold formed lintels.
The service life of IG lintels, when installed with aflexible DPC, will be the same as that anticipatedfor the building. Lintels supplied by IG, almost 60years ago, continue to perform without maintenance- a tested and proven track record.
-
8/9/2019 IG intels brochure
9/88
www.iglintels.com
9BETTER BYDESIGN
Material SpecificationIG Lintels are available in three material types, each with distinctfeatures that can be utilised dependent on your project.
GALVANISED STEEL
IGs standard range of lintels are manufactured fromhigh quality grade pre-galvanised mild steel toBS EN 10346:2009 DX51D plus Z600 or grade Z275 toBS EN10025-2:2004 with minimised spangle finish anda minimum yield stress of 250N/mm. In accordancewith BS5977: part 2, 1983 (BS EN 845-2:2003) all cutedges are treated with a corrosion resistant paint.Table C.1 - material coating reference L14(BS EN 845 part 2 2003 page 28).
STAINLESS STEEL
IGs stainless steel range of lintels use stainless steelgrade 304 2b to BS EN 10088-Part 2 Astm 240(European Grade 1.4307). IGs full range of standardand special lintels are available in stainless steel.
For detailed information on our range of stainlesssteel lintels see page 86.
GALVANISED STEEL/GRP
IGs Hi-Therm lintel range is manufactured from GRPfor the outer leaf and Galvanised steel for the inner leaf.The GRP used is a pultruded fibre reinforced polymermade from polyester resin, fillers and continuousreinforcement consisting of continuous glass fibrestrand roving and glass fibre mat, protected by asurface veil.
POLYSTYRENE INSULATION
IGs lintels are insulated with expanded polystyreneand conforms to BS 13163: 2008. The polystyreneexpansion process involves an air and pentane mixture.The release of pentane into the atmosphere causesno Ozone Depletion or Global Warming therefore ourinsulation has an Ozone Depletion Potential (ODP)and Global Warming Potential (GWP) of ZERO.
The expanded polystyrene (EPS) incorporated into ourpre-insulated lintels does not use, contain or produceformaldehyde, CFCs or indeed any so called CFCs(i.e. HCFC and HFAS). The insulation used in IG lintelsconforms to the Montreal Protocol.
The thermal conductivity of expanded polystyreneis 0.03 W/mK.
Pre-galvanised steel
Continuous profiledinsulation CFC Free
Plaster key
Thermalbreak plate
Pre-galvanised steel
GRP
Continuous profiledinsulation CFC Free
Plaster key
-
8/9/2019 IG intels brochure
10/88
10 LINTEL GUIDE
Specification Clauses
Standard:BS EN 845-2: 2003
Manufacturer:IG Lintels, Avondale Road,Cwmbran, Gwent, NP44 1XYTel: 01633 486 486Web: www.iglintels.com
Product Reference:
Types:
Material/Finish:As product
Sizes:As required and to achieve aminimum end bearing of 150mm(200mm for heavy duty lintels).
Additional requirements:
Placement: Bed on mortar usedfor adjacent work, bearing length(minimum) 150mm.
NBS plus specifications areavailable on www.iglintels.comorvia RIBA for NBS plus subscribers
Single Leaf Lintel
NBS 755:Prefabricated Steel Lintels
Clause F30: Masonry: Accessories/Sundry items for brick/block/stone cladding
Cavity Wall Lintel
Provide IG insulated steel lintels withintegral plaster key and Thermal BreakPlate, manufactured and designed inaccordance with BS EN 845-2:2003.IG Lintels, Avondale Road, Cwmbran,Gwent, NP44 1XY, Tel: 01633 486 486,Web: www.iglintels.com
Product Reference:
IG:L1/L5... /L6...
Length:
Material:High quality grade galvanised steel toBS EN 10346:2009 DX51D standardplus Z600.
Installation:Lintels to have a minimum end bearingof 150mm on each side of the opening,bedded on mortar. Level the lintel alongits length and across its width. Raise theinner and outer leaves simultaneously,masonry to be laid on a mortar bed andall perpendicular joints to be filled.Lintels may be propped to facilitatespeed of construction.
Provide IG steel lintels manufacturedand designed in accordance withBS EN 845-2:2003.IG Lintels, Avondale Road, Cwmbran,Gwent, NP44 1XY, Tel: 01633 486 486,
Web: www.iglintels.comProduct Reference:IG:L9.../ L10.../ L11.../ BOX
Length:
Material:High quality grade galvanised steel toBS EN 10346:2009 DX51D standardplus Z600.
Installation:Lintels to have a minimum end bearingof 150mm on each side of the opening,
bedded on mortar. Level the lintel alongits length and across its width. Masonryto be laid on a mortar bed and allperpendicular joints to be filled.Lintels may be propped to facilitatespeed of construction.
Timber Frame Lintel
Provide IG steel lintels manufacturedand designed in accordance withBS EN 845-2:2003. IG Lintels,Avondale Road, Cwmbran,Gwent, NP44 1XY,Tel: 01633 486 486Web: www.iglintels.com
Product Reference:
IG:L7/
Length:
Material:High quality grade galvanisedsteel to BS EN 10346:2009DX51D standard plus Z600.
Installation:Lintels to have a minimum endbearing of 150mm on each sideof the opening, bedded on mortar.Level the lintel along its lengthand across its width. Masonry tobe laid on a mortar bed and allperpendicular joints to be filled.Restraint clips are to be installedas per IG installation instructions.Lintels may be propped tofacilitate speed of construction.
Extended Product Range
Provide IG insulated steel lintelsmanufactured and designed inaccordance with BS EN 845-2:2003.IG Lintels, Avondale Road,Cwmbran, Gwent, NP44 1XY,
Tel: 01633 486 486,Web: www.iglintels.com
Product Reference:IG: L...
Material:High quality grade galvanisedsteel to BS EN 10346:2009DX51D standard plus Z600.
Installation:Lintels to have a minimum endbearing of 150mm on each sideof the opening, bedded on mortar.
Level the lintel along its lengthand width. Raise the inner andouter leaves simultaneously,masonry to be laid on a mortarbed and all perpendicular joints tobe filled. Lintels may be proppedto facilitate speed of construction.
Stainless SteelLintel Applications
Provide IG insulated Stainless SteelLintels with patented Thermal BreakPlate. Manufactured and designed inaccordance with BS EN 845-2:2003.
IG Lintels, Avondale Road, Cwmbran,Gwent, NP44 1XY, Tel: 01633 486 486,Web: www.iglintels.com
Product Reference:IG:Stainless Steel Lintel SS
Length:
Material:Stainless steel grade 304 2B toBS EN 10088-Part 2 Astm 240(European Grade 1.4307)
Installation:
Lintels to have a minimum end bearingof 150mm on each side of the openingbedded on mortar. Level the lintel alongits length and across its width. Raisethe inner and outer leaves of masonrysimultaneously. Lintels may be proppedto facilitate speed of construction.
-
8/9/2019 IG intels brochure
11/88
www.iglintels.com
11BETTER BYDESIGN
IG LINTEL ACCESSORIES
Lintel Cavity Weep Hole
Provide IG cavity weep holes withcavity wall lintels.IG Lintels, Avondale Road, Cwmbran,Gwent, NP44 1XY, Tel: 01633 486 486Web: www.iglintels.com
Product Reference:IG:WH
Installation:Insert lintel cavity weep holes at450mm centres. At least two peropening must be installed on theouter flange of the lintel.
Lintel Stop Ends
Provide IG lintel stop ends to cavitywall lintels.IG Lintels, Avondale Road, Cwmbran,Gwent, NP44 1XY, Tel: 01633 486 486Web: www.iglintels.com
Product reference:IG:SE
Installation:Place lintel stop ends on both ends ofthe outer flange of the lintel. Ensurethat the stop end is positioned tightlyagainst the front upstand of the lintel.Adjust the stop end to suit the lintelprofile. Position the stop ends in aperpendicular joint nearest the endof the lintel.
Lintel Arch Boards
Provide IG white Arch Board.IG Lintels, Avondale Road, Cwmbran,Gwent, NP44 1XY, Tel: 01633 486 486,Web: www.iglintels.com
Product Reference:IG:AR
Installation:Place arch board on the outer flangeof the lintel. Brickwork on top of archboard must be built on a 10mm bedof mortar.
Lintel Soffit Cladding
Provide PVCu IG Soffit Cladding.IG Lintels, Avondale Road, Cwmbran,Gwent, NP44 1XY, Tel: 01633 486 486Web: www.iglintels.com
Product Reference:IG: SCW
Installation:Attach the built in plastic clip end tothe front outer flange of the lintel.The length of the Lintel soffit shouldbe the same as the opening, not thelength of the lintel.
Cavity Trays
Provide IG Gable Abutement Cavity Trayand or Refurbishment Cavity Tray andor Internal or External Corner Tray.IG Lintels, Avondale Road, Cwmbran,Gwent, NP44 1XY, Tel: 01633 486 486Web: www.iglintels.com
Product Reference:IG:GA1/ GA2/ GA3.../RFT
Installation:Trays to be folded as instructions ontray, to form left and right stop endsas required.
Brick Arch Sets
Provide IG Brick Arch Sets.IG Lintels, Avondale Road, Cwmbran,Gwent, NP44 1XY, Tel: 01633 486 486Web: www.iglintels.com
Product Reference:IG:BA
Installation:Lintels to have a minimum end bearingof 150mm on each side of the opening,bedded on mortar. Level the lintel alongits length and across its width. Raise theinner and outer leaves simultaneously.
All joints to be filled after lintel has beenbuilt in. Lintels may be proppedto facilitate speed of construction.
Windposts
Provide IG Windposts.IG Lintels, Avondale Road, Cwmbran,Gwent, NP44 1XY, Tel: 01633 486 486Web: www.iglintels.com
Product Reference:U1...U9/ LP1...LP12/ DU3...DU9
Material:Austenitic Stainless Steel Grade 304.
Installation:Windposts to be bolted to ground andintermediate floor structures. Windpost
spacing determined by IG Engineer. LPWindpost to be built into blockwork. DUand U windposts to be placed in cavity.
-
8/9/2019 IG intels brochure
12/88
12 LINTEL GUIDE
Lintel Installation Guide
1 Lintels should be installed with a minimum endbearing of 150mm, bedded on mortar andlevelled along its length and across its width.
2 The masonry above the lintel should be builtin accordance with BS EN 1996-2:2006.
3 Raise the inner and outer leaves simultaneously
to avoid excessive eccentricity of loading,with a maximum height difference of 225mm(masonry should be laid on a mortar bed andall perpendicular joints should be filled).
4 Allow the mortar to cure before applyingfloor or roof loads (Temporary proppingbeneath a steel lintel is practised to facilitatespeed of construction).
5 The NHBC recommend a damp proof course(DPC) or cavity tray should be installed over
all openings in external cavity walls.
6 When installing concrete floor units or otherheavy components above a lintel, care shouldbe taken to avoid shock loading and floorunits should not be dragged into position.Masonry immediately above the lintel shouldbe allowed to cure.
7 Point loads should not be applied directly ontolintel flanges. Lintels should have a minimumof 150mm masonry between the flange andthe application level of any form of loading.Consult IGs technical department if applyinga point load above a lintel.
8 The external lintel flange must project beyondthe window/door frame and it is recommendedthat a flexible sealing compound is usedbetween the underside of the lintel flangeand the frame.
9 When the underside of a lintel is exposed, its
appearance can be enhanced by the additionof lintel soffit cladding.
10 Do not cut lintels to length or modify themin any way without consulting an IG engineer.
ENSURE LINTEL IS LEVEL ALONG ITS LENGTH
OUTSIDE INSIDE
Ensure lintel isfully bedded onbricklaying mortar.
Ensure lintel isfully bedded onbricklaying mortar.
Ensure lintel is level across its width.
Ensure lintel is fully bedded onbricklaying mortar
Ensure a nominal150mm endbearing ateach end.
Ensure lintel isnot damaged.
150mmminimum
150mmminimum
Structural openingor clear span
Ensure lintel is level along its length.
ENSURE LINTEL IS LEVEL ALONG ITS WIDTH
-
8/9/2019 IG intels brochure
13/88
www.iglintels.com
13BETTER BYDESIGN
DAMP PROOF COURSE - DPC
LINTEL POSITION WITHIN A CAVITY WALL
PROPPING
A Lintel should be centred inthe cavity and the distancebetween lintel up-stand andmasonry must not exceed 8.5mm
B Masonry should not overhangany flange by more than 30mm.
Propping a lintel is sometimespracticed to facilitate speed ofconstruction. It should only beintroduced after initial masonry loadhas been applied to the lintel.
When propping a lintel, a horizontal
timber plank should be placedalong the underside of the lintel andsuitable* props secured into placeat maximum 1200mm centres.
* Suitability of props is theresponsibility of site management.
In accordance with BS EN 1996-2:2006and NHBC requirements all externalwall lintels MUST be installed witha flexible damp proof course withthe exception of those adequatelyprotected by an eaves overhang orsimilar form of protection.
Stop ends should be provided asspecified by BS EN 1996-2:2006and the NHBC, to avoid moistureentering the cavity near the reveals.Proprietary stop ends should be usedor alternatively the DPC should extendto the edge of the external lintel flangeand 50-150mm beyond the end of thelintel (depending on coursing) to allowformation of an integral stop end at asuitable perpendicular joint.
Provide weep holes at a maximumof 450mm intervals (at least two peropening) with fair-faced masonry.
Consider the use of soffit claddingfor all coastal sites. Stainless steel to beused within 500mof the coast (NHBC).
OUTSIDE INSIDE
AAB
OUTSIDE INSIDE
Timber Plank
SAFETY PRECAUTIONS
IG steel products are produced
from steel plate which maypresent sharp edges. Suitablepersonal protective equipmentshould be worn at all times duringhandling and installation. Glovesshould be worn to avoid injuryfrom any sharp edges or corners.
When lifting or carrying alintel undertake a personal riskassessment paying attentionto the size and weight of theproduct. To avoid lifting strains
any lintels other than the shortestlengths should be lifted by atleast two people or alternativelyby mechanical means.
Do not use damaged lintels.
STORAGE
Lintels should be stored on woodenskids on flat ground. IG recommendsthat they are stored one bundle highonly, unless adequate measures aretaken to ensure that the stack willremain stable. The banding strapsare taut and care should be takenwhen cutting these to avoid personalinjury and/or the bundle collapsing.
DISPOSAL
Ensure that all IG packaging andwaste are disposed of responsibly.Due care must be given to theenvironmental impact of thedisposal method.
COSHH - Control of SubstancesHazardous to Health
IG lintels are fabricated fromgalvanised or stainless steel andpose notoxicity hazard, they arealso insulated with preformedpolystyrene. Most lintels containa perforated steel key platefor rendering purposes and/or asteel strengthening plate for heavyduty requirements which alsoposes no hazard.
All components and materials inour products are considered as
non-hazardous to healthunder normal conditions ofuse as determined by COSHHRegulations 2002.
-
8/9/2019 IG intels brochure
14/88
14 LINTEL GUIDE
Selecting the correct lintelYOU WILL NEED TO KNOW 5 THINGS:1: What is the wall construction?
2: What is the length of the lintel?
3: What is the load to be supported by the lintel?
4: What is the load ratio between the inner and outer leaves of the cavity wall?
5: How to interpret the load tables.
1: Select Wall Type
2: What is the length of the lintel?
CavityWall
TimberFrame
SingleLeaf
SolidWall
InternalPartition
ExternalSolid Wall
You will need to know:
A Outer Leaf = 102mm Brick
B Cavity = 100mm
C Inner Leaf = 100mm Block
Example 1:Cavity Wall Construction
Example 2:Lintel Length
Ensure a150mm endbearing ateach end.
150mm
minimum
150mm
minimum
Structural openingor clear spane.g 1800mm
How wide is thestructural opening?
1 Measure the size of the structuralopening i.e. the clear span
between the masonry supports.
2 Add 150mm minimum bearingto each end.
Example lintel length =150 + 1800 + 150 = 2100mm
OUTERLEAF
INNERLEAF
102mmOuter Leaf
A
100mmCavity
B
100mmInner Leaf
C
hnominal
-
8/9/2019 IG intels brochure
15/88
www.iglintels.com
15BETTER BYDESIGN
Manufactured length150mm increments
600 -1200
1350 -1500
1650 -1800
1950 -2100
2250 -2400
2550 -2700
2850 -3000
3150 -3600
3750 -4050
4200 -4800
Height h 88
1.6
12
10
88
2.0
16
13
107
2.0
19
16
125
2.0
21
17
150
2.0
23
18
162
2.6
27
22
171
2.6
27
20
200
3.2
27
20
200
3.2
26
19
200
3.4
27
22
Thickness
Total UDL kN 3:1
Total UDL kN 19:1
L1/S 100 For cavity widths 90-105mm
3: What is the load to be supported by the lintel?
4: What is the load ratio between the inner and outer leaves of cavity wall?
5: How to interpret the load tables
Example 3:Load on Lintel
kN kNkNThe load on a lintel comes from...
1 Masonry
2 Roof Loads: Truss/Attic/Cut/
3 Floor Loads: Joists/Slabs/
4 Live Loads: Residential use/ Commercial use/Industrial use/
5 Combination of above
NOTE:If you are not skilled in assessing loads please contact IGs Technical Team on 01633 486 486
Total UDL kN 19:1Up to 95% of the loadis on the Inner Leaf
Total UDL kN 3:1Up to 75% of the loadis on the Inner Leaf
25% 75% 5% 95%
InnerLeaf
OuterLeaf Total
Load (kN) 15 5 20
Load ratio 3 1 3:1
Example 4:
Load / ratio calculation:
Differential load ration 3:1 = 75% load on the Inner Leaf 25% load on the Outer Leaf
Differential load ration 19:1 = 95% load on the Inner Leaf 5% load on the Outer Leaf
Total UDL
The UDL (UniformlyDistributed Load) is the totalload in (kN) that is uniformlydistributed along the span
of the lintel relative to theload ratio.
See Example 4
Manufactured length150mm increments
Denotes the lintel lengths including
end bearing. The 2100mm long lintelin Example 2 is listed in this column.
See Example 2
For cavity widths 90 -105mm
The lintels listed in this table are designedfor cavities 95mm to 105mm wide.
See Example 1
L1/S 100
This is the specification code that you shouldreference when contacting an IG Engineer.
L1 Lintel type 1
S Standard Loading
100 100mm Cavity Width
Se
lectin
gthecorrect
Lin
tel
-
8/9/2019 IG intels brochure
16/88
16 LINTEL GUIDE
CAVITY
100mm Inner LeafCavity Width 50-165mm
125 - 150mm Inner LeafCavity Width 50-165mm
125 - 150mm Outer LeafCavity Width 50-165mm
215mm Inner LeafCavity Width 50-165mm
215mm Outer LeafCavity Width 50-165mm
Lintel Range Index
CAVITY WALL - 100mm INNER LEAF
CAVITY WALL - WIDE INNER LEAF
CAVITY WALL - WIDE OUTER LEAF
EAVES LINTEL
HI-THERM STEEL/GRP LINTEL - CAVITY WALL
WALL TYPE
Standard Loading HT/S 19
Heavy Duty Loading HT/HD 19
Standard Loading L1/S 20
Heavy Duty Loading L1/HD 22
L1/XHD 24
Extra Heavy Duty Loading L5 26
L5/XHD 28
Extreme Duty Loading L6 30
Standard Loading L1/S WIL 32
Heavy Duty Loading L1/HD WIL 34
L1/XHD WIL 36
Extra Heavy Duty Loading L5 WIL 38
L5/XHD WIL 40
Extreme Duty Loading L6 WIL 42
Standard Loading L1/S WOL 50
Heavy Duty Loading L1/HD WOL 52
L1/XHD WOL 54Extra Heavy Duty Loading L5 WOL 56
L5/XHD WOL 58
Extreme Duty Loading L6 WOL 60
Standard Loading L1/E 50 65
L1/E 100 65
Standard Loading L1/S WIL 215 44
Heavy Duty Loading L1/HD WIL 215 46
Extreme Duty Loading L6 WIL 215 48
Standard Loading L1/S WOL 215 62
LOADING TYPE CODE PAGE
LOADING CODE PAGE
LOADING TYPE CODE PAGE
LOADING TYPE CODE PAGE
LOADING TYPE CODE PAGE
LOADING TYPE CODE PAGE
102 100CAVITY
102 100CAVITY
102 150CAVITY
102 215
215 100
150 100
Psi 0.05 W/m.K
CAVITY
CAVITY
GALVANISED STEEL LINTEL RANGE
-
8/9/2019 IG intels brochure
17/88
www.iglintels.com
17BETTER BYDESIGN
LOADING TYPE CODE PAGE
LOADING TYPE CODE PAGE
LOADING TYPE CODE PAGESOLID WALL - 215mm WALL WIDTH
SOLID WALL - 150mm WALL WIDTH
WALL TYPE LOADING CODE PAGE
PRODUCT TYPE CODE PAGE
LOADING TYPE CODE PAGE
LOADING TYPE CODE PAGE
SOLID WALL - 100mm WALL WIDTH
Standard Loading INT 100 66
L9 SW 100 66
BOX 75 68
BOX 100 69
Heavy Duty Loading HD BOX 100 70
Thin Joint Lintels L1/TJ 50, L9/TJ 80
Roller Shutter 82
Cant Brick/Stepped Lintel 83
Feature Plate 83
Universal Arch Lintel IGAR 83
Weep Vents & Stop Ends 84
Standard Loading BOX 140 69
Heavy Duty Loading HD BOX 140 70
Standard Loading L7 73
Heavy Duty Loading L7/HD 74
Extra Heavy Duty Loading L7/XHD 75
Standard Loading L8 76
L8 RB 77
L10 78
L11 79
TIMBER FRAME WALL
SINGLE LEAF WALL
EXTENDED LINTEL RANGE
PAGESTAINLESS STEEL RANGE LINTEL RANGE
86IG Standard Lintels are also available in stainless steel.Outstanding durability through austenitic chromiunnickel steel BS EN10088-part 2 Astm 240 (EuropeanGrade 1.4307). Suitable for use in coastal andindustrial environments. All IG galvanised steelloading tables apply.
LintelRange
Se
lect
ion
Index
Standard Loading L9 67
I BEAM 2C 67
I BEAM 3C 67
BOX 200 69
Heavy Duty Loading HD BOX 200 71
Extra Heavy Duty Loading I BEAM XHD 67
Various Cavity Widths
Various Cavity Widths
Various Cavity Widths
-
8/9/2019 IG intels brochure
18/88
LINTELGUIDE
18
DAMP PROOFINGNot required on Hi-Therm lintels.*Check severe exposure.
Cavity Wall
Hi-Therm Lintel
Cavity widths from90mm to 165mm
OUTER LEAF INNER LEAF
102mm 100mm
IG leads the way with the development of a completely unique lintelrange to address the thermal requirements of new building regulations.
Psi 0.05 W/m.K
Testing of IGs Hi-Therm Lintel was carried out bythe BRE (Building Research Establishment) usingPhysibels thermal analysis software TRISCOwhich complies with BS EN ISO 10211-1.The modeling follows the requirements ofthe BRE conventions document BR497.
To help understand the immense thermal benefitsof the Hi-Therm Lintel it must be compared toother lintel types.
Galvanised Steel
Insulation fixed inplace by IG
GRP
THERMAL
PERFORMANCE
TESTING
Plated Steel Lintel (default) 0.5 W/m. K
Non-plated Steel Lintel (default) 0.3 W/m.K
0.23 W/m.KTypical IG Lintel
0.05 W/m.KIG Hi-Therm Lintel
Lintel type comparison Values
Up to 5 times more thermally efficientthan a steel cavity wall lintel, Hi-Thermoutperforms other lintels.
The significant reductions in thermalbridging due to the GRP component will
assist in the building design process toachieve compliance with Part L and TheCode for Sustainable Homes.
The use of Hi-Therm will make asignificant contribution to a buildingsperformance in respect of the FabricEnergy Efficiency Standards (FEES).
Outperforms Stainless Steel on priceand corrosion resistance.
Hi-Therm has achieved the 1 hour fireresistance test as carried out by Exova
Warringtonfire utilising the heatingconditions of BS EN 1363-1 1999.
DESIGN FEATURES
Patented GRP and Galvanised Steelhybrid design.
Galvanised steel is used to support theheavier load on the inner leaf of thecavity wall.
Profiled CFC free insulation ensures
the continuity of insulation.
KEY BENEFITS
Psi COMPARISON CHART
If lintels are required to carryloads not indicated on theload tables, please contactIGs Technical Department.
Fax Back Enquiry Forms are
also available for download.
LINTEL HOTLINE
01633 486486
www.iglintels.com/technical
IG Fastrack CAD Databaseisaccessible from iglintels.com
Building regulations require that lintels should beassessed for their effect on the thermal performanceof a building. The thermal performance of a lintelis expressed in terms of Psi Values() i.e. linearthermal transmittance.
-
8/9/2019 IG intels brochure
19/88
www.iglintels.com
19
For cavity widths 90-105mm
For cavity widths 90-105mm
For cavity widths 130-145mm
For cavity widths 130-145mm
For cavity widths 150-165mm
For cavity widths 150-165mm
Blockwork built tight against inner face of the
lintel. Place mortar bed on top of blockworkbefore floor units are laid to provide evendistribution of load. Lintels may be proppedto facilitate speed of construction. See LintelInstallation on page 12. Insulation fixed ontop of the lintel has been cut back on thisillustration for clarity.
NOTE The exact lintel profile will vary dependent on lintel length and loading
NOTE The exact lintel profile will vary dependent on lintel length and loading
HT/S Standard LoadHT/HD Heavy Duty Load
HT/S 100
HT/HD 100
HT/S 130
HT/HD 130
HT/S 150
HT/HD 150
hnominal
102mm
Ou
ter
Lea
f
100mm
Inner
Lea
fHI-THERM LINTEL
hnominal
95 10088
95 10088
Height h 135 150 229 215
Thickness 2.5 2.9 2.9 3.2
Total UDL kN 3:1 20 21 27 27
Total UDL kN 19:1 17 17 20 20
Height h 150 229 229 215
Thickness 3.2 2.9 3.2 2.9
Total UDL kN 3:1 30 40 40 35
Total UDL kN 19:1 22 35 35 32
Manufactured length 600- 1650- 2250- 3150-
150mm increments 1500 2100 3000 3600
Manufactured length 600- 1650- 2550- 3150-
150mm increments 1500 2400 3000 3600
Standard Load
Heavy Duty Load
-
8/9/2019 IG intels brochure
20/88
LINTELGUIDE
20
DAMP PROOFINGProvide a damp proof course over all lintels. Please see IG installation details for guidance on page 12.
Cavity Wall
Standard Load
Cavity widths from50mm to 165mm
OUTER LEAF INNER LEAF
102mm 100mm
90-105mmcavityL1/S 100
95 100
h
nominal
88
For cavity widths 50-65mm
For cavity widths 70-85mm
For cavity widths 90-105mm
70-85mmcavity
L1/S 50
L1/S 75
95 100
hnominal
48
95 100
hnominal
68
50-65mmcavity
Height h 79 95 110 134 150 172 172 209 209 209
Thickness 1.6 2.0 2.0 2.0 2.0 2.0 2.6 3.2 3.2 3.4
Total UDL kN 3:1 12 14 19 21 21 26 27 27 26 27
Total UDL kN 19:1 10 12 16 17 19 22 20 20 19 22
Height h 88 88 107 125 150 162 171 200 200 200
Thickness 1.6 2.0 2.0 2.0 2.0 2.6 2.6 3.2 3.2 3.4
Total UDL kN 3:1 12 16 19 21 23 27 27 27 26 27
Total UDL kN 19:1 10 13 16 17 18 22 20 20 19 22
Height h 98 89 106 130 142 168 204 204 204
Thickness 1.6 2.0 2.0 2.0 2.0 2.6 3.2 3.2 3.4
Total UDL kN 3:1 12 14 18 21 21 27 27 26 27
Total UDL kN 19:1 10 12 14 17 19 22 20 19 22
Manufactured length 600- 1350- 1650- 1950- 2250- 2550- 2850- 3150- 3750- 4200-
150mm increments 1200 1500 1800 2100 2400 2700 3000 3600 4050 4800
Manufactured length 600- 1350- 1650- 1950- 2250- 2550- 2850- 3150- 3750- 4200-
150mm increments 1200 1500 1800 2100 2400 2700 3000 3600 4050 4800
Manufactured length 600- 1350- 1650- 1950- 2250- 2550- 3150- 3750- 4200-
150mm increments 1200 1500 1800 2100 2400 3000 3600 4050 4800
If lintels are required to carryloads not indicated on theload tables, please contactIGs Technical Department.
Fax Back Enquiry Forms are
also available for download.
LINTEL HOTLINE
01633 486486
www.iglintels.com/technical
IG Fastrack CAD Databaseisaccessible from iglintels.com
-
8/9/2019 IG intels brochure
21/88
www.iglintels.com
21
L1/S 130
110-125mmcavityL1/S 110
95 100
hnominal
128
95 100
hnominal
108
130-145mmcavity
For cavity widths 110-125mm
For cavity widths 130-145mm
Blockwork built tight against inner faceof the lintel. Place mortar bed on topof blockwork before floor units are laidto provide even distribution of load.Lintels may be propped to facilitate
speed of construction. See LintelInstallation on page 12.
HEAVIER LOADINGSTables for heavier loads overleaf.
L1/SSTANDARD LOAD
95 100
hnominal
148
150-165mmcavityL1/S 150 For cavity widths 150-165mm
102mm
Ou
ter
Lea
f
100mm
Inner
Lea
f
Height h 95 121 145 195 195 195
Thickness 2.0 2.0 2.6 2.9 3.2 3.4
Total UDL kN 3:1 16 22 24 27 26 25
Total UDL kN 19:1 13 18 18 22 19 20
Height h 103 128 190 190 190 190
Thickness 2.0 2.0 2.5 2.9 3.2 3.4
Total UDL kN 3:1 16 22 24 27 26 25
Total UDL kN 19:1 13 18 18 22 19 20
Height h 100 125 180 180 180 180
Thickness 2.0 2.0 2.6 2.9 3.2 3.4
Total UDL kN 3:1 16 22 24 27 26 25
Total UDL kN 19:1 13 18 18 22 19 20
Manufactured length 600- 1650- 1950- 2250- 3150- 4200-
150mm increments 1500 1800 2100 3000 4050 4800
Manufactured length 600- 1650- 1950- 2250- 3150- 4200-
150mm increments 1500 1800 2100 3000 4050 4800
Manufactured length 600- 1650- 1950- 2250- 3150- 4200-
150mm increments 1500 1800 2100 3000 4050 4800
-
8/9/2019 IG intels brochure
22/88
-
8/9/2019 IG intels brochure
23/88
www.iglintels.com
23
L1/HD 130
110-125mmcavityL1/HD 110
95 100128
95 100108
130-145mmcavity
For cavity widths 110-125mm
For cavity widths 130-145mm
HEAVIER LOADINGSTables for heavier loads overleaf.
95 100148
150-165mmcavityL1/HD 150 For cavity widths 150-165mm
102mm
Ou
ter
Lea
f
100mm
Inner
Lea
f
Height h 125 145 195 195 195
Thickness 2.9 2.9 2.9 3.2 3.2
Total UDL kN 3:1 30 30 35 32 30
Total UDL kN 19:1 20 22 30 28 26
Height h 115 155 190 190 212
Thickness 2.9 2.9 3.2 3.2 3.2
Total UDL kN 3:1 30 30 35 30 30
Total UDL kN 19:1 20 22 30 25 26
Height h 125 160 180 180 200
Thickness 2.9 2.9 3.2 3.2 3.2
Total UDL kN 3:1 30 30 35 30 30
Total UDL kN 19:1 20 22 30 25 26
Manufactured length 600- 1650- 2250- 3150- 3750-
150mm increments 1500 2100 3000 3600 4050
Manufactured length 600- 1650- 2250- 3150- 3750-
150mm increments 1500 2100 3000 3600 4050
Manufactured length 600- 1650- 2250- 3150- 3750-
150mm increments 1500 2100 3000 3600 4050
hnominal
hnominal
hnominal
Blockwork built tight against inner faceof the lintel. Place mortar bed on topof blockwork before floor units are laidto provide even distribution of load.Lintels may be propped to facilitate
speed of construction. See LintelInstallation on page 12.
L1/HDHEAVY DUTY LOAD
-
8/9/2019 IG intels brochure
24/88
LINTELGUIDE
24
If lintels are required to carryloads not indicated on theload tables, please contactIGs Technical Department.
Fax Back Enquiry Forms are
also available for download.
LINTEL HOTLINE
01633 486486
www.iglintels.com/technical
IG Fastrack CAD Databaseisaccessible from iglintels.com
Height h 171 171 209 209
Thickness 3.2 3.2 3.2 3.2
Total UDL kN 3:1 50 50 55 50
Total UDL kN 19:1 45 45 45 40
Height h 167 167 205 205
Thickness 3.2 3.2 3.2 3.2
Total UDL kN 3:1 50 50 55 50
Total UDL kN 19:1 45 45 45 40
Height h 163 163 203 203
Thickness 3.2 3.2 3.2 3.2
Total UDL kN 3:1 50 50 55 50
Total UDL kN 19:1 45 45 45 40
Manufactured length 600- 1650- 1950- 2250-
150mm increments 1500 1800 2100 2700
Manufactured length 600- 1650- 1950- 2250-
150mm increments 1500 1800 2100 2700
Manufactured length 600- 1650- 1950- 2250-
150mm increments 1500 1800 2100 2700
DAMP PROOFINGProvide a damp proof course over all lintels. Please see IG installation details for guidance on page 12.
Cavity Wall
Heavy Duty Load
Cavity widths from50mm to 165mm
OUTER LEAF INNER LEAF
102mm 100mm
90-105mmcavityL1/XHD 100
95 10088
For cavity widths 90-105mm
70-85mmcavity
95 10048
95 10068
50-65mmcavity
For cavity widths 70-85mmL1/XHD 75
For cavity widths 50-65mmL1/XHD 50
hnominal
hnominal
hnominal
-
8/9/2019 IG intels brochure
25/88
www.iglintels.com
25
L1/XHD 130
110-125mmcavityL1/XHD 110
95 100128
95 100108
130-145mmcavity
For cavity widths 110-125mm
For cavity widths 130-145mm
HEAVIER LOADINGSTables for heavier loads overleaf.
95 100148
hnominal
hnominal
hnominal
150-165mmcavityL1/XHD 150 For cavity widths 150-165mm
102mm
Ou
ter
Lea
f
100mm
Inner
Lea
f
Height h 145 145 195
Thickness 3.2 3.2 3.2
Total UDL kN 3:1 45 45 50
Total UDL kN 19:1 40 40 40
Height h 155 155 212
Thickness 3.2 3.2 3.2
Total UDL kN 3:1 45 45 50
Total UDL kN 19:1 40 40 40
Height h 160 160 200
Thickness 3.2 3.2 3.2
Total UDL kN 3:1 45 45 50
Total UDL kN 19:1 40 40 40
Manufactured length 600- 1650- 1950-
150mm increments 1500 1800 2100
Manufactured length 600- 1650- 1950-
150mm increments 1500 1800 2100
Manufactured length 600- 1650- 1950-
150mm increments 1500 1800 2100
Blockwork built tight against inner faceof the lintel. Place mortar bed on topof blockwork before floor units are laidto provide even distribution of load.Lintels may be propped to facilitate
speed of construction. See LintelInstallation on page 12.
L1/XHDHEAVY DUTY LOAD
-
8/9/2019 IG intels brochure
26/88
LINTELGUIDE
26
If lintels are required to carryloads not indicated on theload tables, please contactIGs Technical Department.
Fax Back Enquiry Forms are
also available for download.
LINTEL HOTLINE
01633 486486
www.iglintels.com/technical
IG Fastrack CAD Databaseisaccessible from iglintels.com
DAMP PROOFINGProvide a damp proof course over all lintels. Please see IG installation details for guidance on page 12.
Cavity Wall
Extra Heavy Duty Load
Cavity widths from50mm to 165mm
OUTER LEAF INNER LEAF
102mm 100mm
90-105mmcavityL5/ 100
95 10088
For cavity widths 90-105mm
70-85mmcavity
95 10048
95 10068
50-65mmcavity
For cavity widths 70-85mmL5/ 75
For cavity widths 50-65mmL5/ 50
Height h 229 229 229
Thickness 2.5 3.0 3.0
Total UDL kN 19:1 48 50 38
Height h 229 229 229
Thickness 2.5 3.0 3.0
Total UDL kN 19:1 48 50 38
Height h 229 229 229
Thickness 2.5 3.0 3.0
Total UDL kN 19:1 48 50 38
Manufactured length 600- 2550- 3750-
150mm increments 2400 3600 4800
Manufactured length 600- 2550- 3750-
150mm increments 2400 3600 4800
Manufactured length 600- 2550- 3750-
150mm increments 2400 3600 4800
hnominal
hnominal
hnominal
-
8/9/2019 IG intels brochure
27/88
www.iglintels.com
27
L5/ 130
110-125mmcavityL5/ 110
95 100128
95 100108
hnominal
hnominal
130-145mmcavity
For cavity widths 110-125mm
For cavity widths 130-145mm
HEAVIER LOADINGSTables for heavier loads overleaf.
95 100148
150-165mmcavityL5/ 150 For cavity widths 150-165mm
102mm
Ou
ter
Lea
f
100mm
Inner
Lea
f
Height h 229 229 229
Thickness 2.5 3.0 3.0
Total UDL kN 19:1 48 50 38
Height h 229 229 229
Thickness 2.5 3.0 3.0
Total UDL kN 19:1 48 50 38
Height h 229 229 229
Thickness 2.5 3.0 3.0
Total UDL kN 19:1 48 50 38
Manufactured length 600- 2550- 3750-
150mm increments 2400 3600 4800
Manufactured length 600- 2550- 3750-
150mm increments 2400 3600 4800
Manufactured length 600- 2550- 3750-
150mm increments 2400 3600 4800
hnominal
To achieve loading figures lintelmust be built in with blockwork asshown. Ensure all perpendicularand horizontal joints are filled withmortar. Place mortar bed on top of
blockwork before floor units are laidto provide even distribution of load.Lintels may be propped to facilitatespeed of construction. See LintelInstallation on page 12.
L5EXTRA HEAVY DUTY LOAD
-
8/9/2019 IG intels brochure
28/88
LINTELGUIDE
28
If lintels are required to carryloads not indicated on theload tables, please contactIGs Technical Department.
Fax Back Enquiry Forms are
also available for download.
LINTEL HOTLINE
01633 486486
www.iglintels.com/technical
IG Fastrack CAD Databaseisaccessible from iglintels.com
DAMP PROOFINGProvide a damp proof course over all lintels. Please see IG installation details for guidance on page 12.
Cavity Wall
Extra Heavy Duty Load
Cavity widths from50mm to 165mm
OUTER LEAF INNER LEAF
102mm 100mm
90-105mmcavityL5/XHD 100
95 10088
For cavity widths 90-105mm
70-85mmcavity
95 10048
95 10068
50-65mmcavity
For cavity widths 70-85mmL5/XHD 75
For cavity widths 50-65mmL5/XHD 50
Height h 235 235 235 235 235
Thickness Inner 5.0 5.0 5.0 5.0 5.0
Thickness Outer 2.9 2.9 2.9 3.2 3.2
Total UDL kN 19:1 100 90 80 65 50
Height h 235 235 235 235 235
Thickness Inner 5.0 5.0 5.0 5.0 5.0
Thickness Outer 2.9 2.9 2.9 3.2 3.2
Total UDL kN 19:1 100 90 80 65 50
Height h 235 235 235 235 235
Thickness Inner 5.0 5.0 5.0 5.0 5.0
Thickness Outer 2.9 2.9 2.9 3.2 3.2
Total UDL kN 19:1 100 90 80 65 50
Manufactured length 600- 1950- 2550- 3150- 3750-
150mm increments 1800 2400 3000 3600 4800-
Manufactured length 600- 1950- 2550- 3150- 3750-
150mm increments 1800 2400 3000 3600 4800-
Manufactured length 600- 1950- 2550- 3150- 3750-
150mm increments 1800 2400 3000 3600 4800-
hnominal
hnominal
hnominal
-
8/9/2019 IG intels brochure
29/88
www.iglintels.com
29
L5/XHD 130
110-125mmcavityL5/XHD 110
95 100128
95 100108
hnominal
hnominal
130-145mmcavity
For cavity widths 110-125mm
For cavity widths 130-145mm
HEAVIER LOADINGSTables for heavier loads overleaf.
95 100148
150-165mmcavityL5/XHD 150 For cavity widths 150-165mm
102mm
Ou
ter
Lea
f
100mm
Inner
Lea
f
Height h 235 235 235 235 235
Thickness Inner 5.0 5.0 5.0 5.0 5.0
Thickness Outer 2.9 2.9 2.9 3.2 3.2
Total UDL kN 19:1 100 90 80 65 50
Height h 235 235 235 235 235
Thickness Inner 5.0 5.0 5.0 5.0 5.0
Thickness Outer 2.9 2.9 2.9 3.2 3.2
Total UDL kN 19:1 100 90 80 65 50
Height h 235 235 235 235 235
Thickness Inner 5.0 5.0 5.0 5.0 5.0
Thickness Outer 2.9 2.9 2.9 3.2 3.2
Total UDL kN 19:1 100 90 80 65 50
Manufactured length 600- 1950- 2550- 3150- 3750-
150mm increments 1800 2400 3000 3600 4800-
Manufactured length 600- 1950- 2550- 3150- 3750-
150mm increments 1800 2400 3000 3600 4800-
Manufactured length 600- 1950- 2550- 3150- 3750-
150mm increments 1800 2400 3000 3600 4800-
hnominal
To achieve loading figures lintelmust be built in with blockwork asshown. Ensure all perpendicularand horizontal joints are filled withmortar. Place mortar bed on top of
blockwork before floor units are laidto provide even distribution of load.Lintels may be propped to facilitatespeed of construction. See LintelInstallation on page 12.
L5/XHDEXTRA HEAVY DUTY LOAD
-
8/9/2019 IG intels brochure
30/88
LINTELGUIDE
30
If lintels are required to carryloads not indicated on theload tables, please contactIGs Technical Department.
Fax Back Enquiry Forms are
also available for download.
LINTEL HOTLINE
01633 486486
www.iglintels.com/technical
IG Fastrack CAD Databaseisaccessible from iglintels.com
263
283
207
207
243
207
DAMP PROOFINGProvide a damp proof course over all lintels. Please see IG installation details for guidance on page 12.
Cavity Wall
Extreme Load
Cavity widths from50mm to 165mm
OUTER LEAF INNER LEAF
102mm 100mm
90-105mmcavityL6/ 100 For cavity widths 90-105mm
70-85mmcavity
50-65mmcavity
For cavity widths 70-85mmL6/ 75
For cavity widths 50-65mmL6/ 50
End Bearing 200 200 200 200 200 200
Total UDL kN 19:1 80 70 62 55 45 40
End Bearing 200 200 200 200 200 200
Total UDL kN 19:1 80 70 62 55 45 40
End Bearing 200 200 200 200 200 200
Total UDL kN 19:1 80 70 62 55 45 40
Manufactured length (mm) 600- 5200 5400 5800 6200 6600
to customer requirements 4800
Manufactured length (mm) 600- 5200 5400 5800 6200 6600
to customer requirements 4800
Manufactured length (mm) 600- 5200 5400 5800 6200 6600
to customer requirements 4800
-
8/9/2019 IG intels brochure
31/88
www.iglintels.com
31
303
323
343
207
207
207
L6/ 130
110-125mmcavityL6/ 110
130-145mmcavity
For cavity widths 110-125mm
For cavity widths 130-145mm
150-165mmcavityL6/ 150 For cavity widths 150-165mm
102mm
Ou
ter
Lea
f
100mm
Inner
Lea
f
End Bearing 200 200 200 200 200 200
Total UDL kN 19:1 80 70 62 55 45 40
End Bearing 200 200 200 200 200 200
Total UDL kN 19:1 80 70 62 55 45 40
End Bearing 200 200 200 200 200 200
Total UDL kN 19:1 80 70 62 55 45 40
Manufactured length (mm) 600- 5200 5400 5800 6200 6600
to customer requirements 4800
Manufactured length (mm) 600- 5200 5400 5800 6200 6600
to customer requirements 4800
Manufactured length (mm) 600- 5200 5400 5800 6200 6600
to customer requirements 4800
To achieve loading figures lintel mustbe laterally restrained. Lintels maybe propped to facilitate speed ofconstruction. See Lintel Installationon page 12. Galvanised steel flange
to outer leaf.
L6EXTREME LOAD
-
8/9/2019 IG intels brochure
32/88
LINTELGUIDE
32
If lintels are required to carryloads not indicated on theload tables, please contactIGs Technical Department.
Fax Back Enquiry Forms are
also available for download.
LINTEL HOTLINE
01633 486486
www.iglintels.com/technical
IG Fastrack CAD Databaseisaccessible from iglintels.com
95
95
95
125
125
125
hnominal
h
nominal
68
88
48
hnominal
For cavity widths 90-105mmL1/S 100 WIL
For 150mm wide inner leaf blockwork.
Height h 82 107 142 177 191 187 187
Thickness 1.6 2.0 2.0 2.6 3.2 3.2 3.4
Total UDL kN 3:1 13 17 23 24 30 27 26
Total UDL kN 19:1 11 14 18 18 26 25 21
Manufactured length 600- 1350- 1950- 2550- 3150- 3750- 4200
150mm increments 1200 1800 2400 3000 3600 4050
DAMP PROOFINGProvide a damp proof course over all lintels. Please see IG installation details for guidance on page 12.
Wide Inner Leaf - Cavity Wall
Standard Load
Cavity widths from50mm to 165mm
OUTER LEAF INNER LEAF
102mm 125mm - 150mm
90-105mmcavity
For cavity widths 50-65mm
For cavity widths 70-85mm 70-85mmcavity
L1/S 50 WIL
L1/S 75 WIL
50-65mmcavity
For 150mm wide inner leaf blockwork.
For 150mm wide inner leaf blockwork.
Height h 91 96 110 136 162 172 196 196 196
Thickness 1.6 2.0 2.0 2.0 2.0 2.6 3.2 3.2 3.4
Total UDL kN 3:1 12 12 15 20 24 28 30 27 26
Total UDL kN 19:1 10 10 13 18 20 21 26 25 22
Height h 93 90 100 134 158 167 192 192 192
Thickness 1.6 2.0 2.0 2.0 2.0 2.6 3.2 3.2 3.4
Total UDL kN 3:1 12 13 20 19 24 27 30 27 26
Total UDL kN 19:1 10 11 17 17 20 21 26 25 22
Manufactured length 600- 1500- 1800 1950- 2250- 2550- 3150- 3750- 4200
150mm increments 1350 1650 2100 2400 3000 3600 4050
Manufactured length 600- 1500- 1800 1950- 2250- 2550- 3150- 3750- 4200
150mm increments 1350 1650 2100 2400 3000 3600 4050
-
8/9/2019 IG intels brochure
33/88
www.iglintels.com
33
L1/S 130 WIL
110-125mmcavityL1/S 110 WIL
95
95
95
125
125
125
108
128
148
130-145mmcavity
For cavity widths 110-125mm
For cavity widths 130-145mm
Lintels may be propped to facilitatespeed of construction. See LintelInstallation on page 12. Inner leaf
block should not overhang the lintelflange by more than 25mm.
HEAVIER LOADINGSTables for heavier loads overleaf.
L1/S WIL
STANDARD LOADWIDE INNER LEAF
150-165mmcavityL1/S 150 WIL For cavity widths 150-165mm
102mm
Ou
ter
Lea
f
150mm
Inner
Lea
f
Height h 95 107 142 185 185
Thickness 2.0 2.0 2.6 2.9 3.2
Total UDL kN 3:1 13 17 23 24 24
Total UDL kN 19:1 11 14 18 18 17
Height h 90 118 178 178 178
Thickness 2.0 2.0 2.6 2.9 3.2
Total UDL kN 3:1 13 17 23 24 24
Total UDL kN 19:1 11 14 18 18 17
Height h 88 115 168 168 168
Thickness 2.0 2.0 2.6 2.9 3.2
Total UDL kN 3:1 13 17 23 24 24
Total UDL kN 19:1 11 14 18 18 17
Manufactured length 600- 1350- 1950- 2250- 3150-
150mm increments 1200 1800 2100 3000 4050
Manufactured length 600- 1350- 1950- 2250- 3150-
150mm increments 1200 1800 2100 3000 4050
Manufactured length 600- 1350- 1950- 2250- 3150-
150mm increments 1200 1800 2100 3000 4050
For 150mm wide inner leaf blockwork.
For 150mm wide inner leaf blockwork.
For 150mm wide inner leaf blockwork.
hnominal
hnominal
hn
ominal
-
8/9/2019 IG intels brochure
34/88
LINTELGUIDE
34
If lintels are required to carryloads not indicated on theload tables, please contactIGs Technical Department.
Fax Back Enquiry Forms are
also available for download.
LINTEL HOTLINE
01633 486486
www.iglintels.com/technical
IG Fastrack CAD Databaseisaccessible from iglintels.com
95
95
95
125
125
125
68
88
48
For cavity widths 90-105mmL1/HD 100 WIL
For 150mm wide inner leaf blockwork.
DAMP PROOFINGProvide a damp proof course over all lintels. Please see IG installation details for guidance on page 12.
Wide Inner Leaf - Cavity Wall
Heavy Duty Load
Cavity widths from50mm to 165mm
OUTER LEAF INNER LEAF
102mm 125mm - 150mm
90-105mmcavity
For cavity widths 50-65mm
For cavity widths 70-85mm 70-85mmcavity
L1/HD 50 WIL
L1/HD 75 WIL
50-65mmcavity
For 150mm wide inner leaf blockwork.
For 150mm wide inner leaf blockwork.
Height h 95 110 161 161 200
Thickness 2.9 2.9 2.9 2.9 3.2
Total UDL kN 3:1 20 25 35 30 36
Total UDL kN 19:1 17 22 27 25 32
Height h 130 155 192 192
Thickness 2.9 2.9 2.9 3.2
Total UDL kN 3:1 20 35 30 36
Total UDL kN 19:1 17 27 25 32
Height h 113 144 165 188
Thickness 2.9 2.9 2.9 3.2
Total UDL kN 3:1 20 35 30 36
Total UDL kN 19:1 17 27 25 32
Manufactured length 600- 1350- 1650- 1950- 2250-
150mm increments 1200 1500 1800 2100 2700
Manufactured length 600- 1500- 1950- 2250-
150mm increments 1350 1800 2100 2700
Manufactured length 600- 1500- 1950- 2250-
150mm increments 1350 1800 2100 2700
hnominal
hnominal
hnominal
-
8/9/2019 IG intels brochure
35/88
www.iglintels.com
35
L1/HD 130 WIL
110-125mmcavityL1/HD 110 WIL
95
95
95
125
125
125
108
128
148
130-145mmcavity
For cavity widths 110-125mm
For cavity widths 130-145mm
Lintels may be propped to facilitatespeed of construction. See LintelInstallation on page 12. Inner leaf block
should not overhang the lintel flangeby more than 25mm. Blockwork builttight against inner face of the lintel.Place mortar bed on top of blockworkbefore floor units are laid to provideeven distribution of load.
HEAVIER LOADINGSTables for heavier loads overleaf.
L1/HD WIL
HEAVY DUTY LOADWIDE INNER LEAF
150-165mmcavityL1/HD 150 WIL For cavity widths 150-165mm
102mm
Ou
ter
Lea
f
150mm
Inner
Lea
f
For 150mm wide inner leaf blockwork.
For 150mm wide inner leaf blockwork.
For 150mm wide inner leaf blockwork.
Height h 131 148 195 195
Thickness 2.9 2.9 2.9 3.2
Total UDL kN 3:1 20 30 30 36
Total UDL kN 19:1 17 25 25 32
Height h 115 155 190 212
Thickness 2.9 2.9 2.9 3.2
Total UDL kN 3:1 20 30 30 36
Total UDL kN 19:1 17 25 25 32
Height h 113 148 168 168
Thickness 2.9 2.9 2.9 3.2
Total UDL kN 3:1 20 30 30 36
Total UDL kN 19:1 17 25 25 32
Manufactured length 600- 1500- 1950- 2250-
150mm increments 1350 1800 2100 2700
Manufactured length 600- 1500- 1950- 2250-
150mm increments 1350 1800 2100 2700
Manufactured length 600- 1500- 1950- 2250-
150mm increments 1350 1800 2100 2700
hnominal
hnominal
hnominal
-
8/9/2019 IG intels brochure
36/88
LINTELGUIDE
36
If lintels are required to carryloads not indicated on theload tables, please contactIGs Technical Department.
Fax Back Enquiry Forms are
also available for download.
LINTEL HOTLINE
01633 486486
www.iglintels.com/technical
IG Fastrack CAD Databaseisaccessible from iglintels.com
95
95
95
125
125
125
68
88
48
For cavity widths 90-105mmL1/XHD 100 WIL
For 150mm wide inner leaf blockwork.
DAMP PROOFINGProvide a damp proof course over all lintels. Please see IG installation details for guidance on page 12.
Wide Inner Leaf - Cavity Wall
Heavy Duty Load
Cavity widths from50mm to 165mm
OUTER LEAF INNER LEAF
102mm 125mm - 150mm
90-105mmcavity
For cavity widths 50-65mm
For cavity widths 70-85mm 70-85mmcavity
L1/XHD 50 WIL
L1/XHD 75 WIL
50-65mmcavity
For 150mm wide inner leaf blockwork.
For 150mm wide inner leaf blockwork.
hnominalHeight h 161 196 196
Thickness 3.2 3.2 3.2
Total UDL kN 3:1 45 45 50
Total UDL kN 19:1 40 40 40
Height h 155 192 192
Thickness 3.2 3.2 3.2
Total UDL kN 3:1 45 45 50
Total UDL kN 19:1 40 40 40
Height h 165 188 188
Thickness 3.2 3.2 3.2
Total UDL kN 3:1 45 45 50
Total UDL kN 19:1 40 40 40
Manufactured length 600- 1650- 1950-
150mm increments 1500 1800 2100
Manufactured length 600- 1650- 1950-
150mm increments 1500 1800 2100
Manufactured length 600- 1650- 1950-
150mm increments 1500 1800 2100
hnominal
hnominal
-
8/9/2019 IG intels brochure
37/88
-
8/9/2019 IG intels brochure
38/88
LINTELGUIDE
38
If lintels are required to carryloads not indicated on theload tables, please contactIGs Technical Department.
Fax Back Enquiry Forms are
also available for download.
LINTEL HOTLINE
01633 486486
www.iglintels.com/technical
IG Fastrack CAD Databaseisaccessible from iglintels.com
95
95
95
125
125
125
68
88
48
For cavity widths 90-105mmL5/100 WIL
DAMP PROOFINGProvide a damp proof course over all lintels. Please see IG installation details for guidance on page 12.
Wide Inner Leaf - Cavity Wall
Extra Heavy Duty Load
Cavity widths from50mm to 165mm
OUTER LEAF INNER LEAF
102mm 125mm - 150mm
90-105mmcavity
For cavity widths 50-65mm
For cavity widths 70-85mm 70-85mmcavity
L5/50 WIL
L5/75 WIL
50-65mmcavity
For 150mm wide inner leaf blockwork.
For 150mm wide inner leaf blockwork.
For 150mm wide inner leaf blockwork.
hnominal
hnominal
hnominal
Height h 229 229 229 229 229
Thickness 2.9 2.9 2.9 3.2 3.2
Total UDL kN 19:1 70 60 50 45 40
Height h 229 229 229 229 229
Thickness 2.9 2.9 2.9 3.2 3.2
Total UDL kN 19:1 70 60 50 45 40
Height h 229 229 229 229 229
Thickness 2.9 2.9 2.9 3.2 3.2
Total UDL kN 19:1 70 60 50 45 40
Manufactured length 600- 1650- 2250- 3150- 4200-
150mm increments 1500 2100 3000 4050 4800
Manufactured length 600- 1650- 2250- 3150- 4200-
150mm increments 1500 2100 3000 4050 4800
Manufactured length 600- 1650- 2250- 3150- 4200-
150mm increments 1500 2100 3000 4050 4800
-
8/9/2019 IG intels brochure
39/88
www.iglintels.com
39
hnominal
hnominal
L5/130 WIL
110-125mmcavityL5/110 WIL
95
95
95
125
125
125
108
128
148
130-145mmcavity
For cavity widths 110-125mm
For cavity widths 130-145mm
Lintels may be propped to facilitate speedof construction. See Lintel Installationon page 12. Inner leaf block should notoverhang the lintel flange by more than25mm. Blockwork built tight against innerface of the lintel. Place mortar bed on topof blockwork before floor units are laid toprovide even distribution of load.
HEAVIER LOADINGSTables for heavier loads overleaf.
L5/ WIL
EXTRA HEAVY DUTY LOADWIDE INNER LEAF
150-165mmcavityL5/150 WIL For cavity widths 150-165mm
102mm
Ou
ter
Lea
f
150mm
Inner
Lea
f
For 150mm wide inner leaf blockwork.
Height h 229 229 229 229 229
Thickness 2.9 2.9 2.9 3.2 3.2
Total UDL kN 19:1 70 60 50 45 40
Manufactured length 600- 1650- 2250- 3150- 4200-
150mm increments 1500 2100 3000 4050 4800
For 150mm wide inner leaf blockwork.
Height h 229 229 229 229 229
Thickness 2.9 2.9 2.9 3.2 3.2
Total UDL kN 19:1 70 60 50 45 40
Manufactured length 600- 1650- 2250- 3150- 4200-
150mm increments 1500 2100 3000 4050 4800
For 150mm wide inner leaf blockwork.
Height h 229 229 229 229 229
Thickness 2.9 2.9 2.9 3.2 3.2
Total UDL kN 19:1 70 60 50 45 40
Manufactured length 600- 1650- 2250- 3150- 4200-
150mm increments 1500 2100 3000 4050 4800
hnominal
-
8/9/2019 IG intels brochure
40/88
LINTELGUIDE
40
If lintels are required to carryloads not indicated on theload tables, please contactIGs Technical Department.
Fax Back Enquiry Forms are
also available for download.
LINTEL HOTLINE
01633 486486
www.iglintels.com/technical
IG Fastrack CAD Databaseisaccessible from iglintels.com
95
95
95
125
125
125
68
88
48
For cavity widths 90-105mmL5/XHD 100 WIL
DAMP PROOFINGProvide a damp proof course over all lintels. Please see IG installation details for guidance on page 12.
Wide Inner Leaf - Cavity Wall
Extra Heavy Duty Load
Cavity widths from50mm to 165mm
OUTER LEAF INNER LEAF
102mm 125mm - 150mm
90-105mmcavity
For cavity widths 50-65mm
For cavity widths 70-85mm 70-85mmcavity
L5/XHD 50 WIL
L5/XHD 75 WIL
50-65mmcavity
For 150mm wide inner leaf blockwork.
For 150mm wide inner leaf blockwork.
For 150mm wide inner leaf blockwork.
hnominal
hnominal
Height h 235 235 235 235
Thickness Inner 5.0 5.0 5.0 5.0
Thickness Outer 2.9 2.9 2.9 3.2
Total UDL kN 19:1 100 90 80 65
Height h 235 235 235 235
Thickness Inner 5.0 5.0 5.0 5.0
Thickness Outer 2.9 2.9 2.9 3.2
Total UDL kN 19:1 100 90 80 65
Height h 235 235 235 235
Thickness Inner 5.0 5.0 5.0 5.0
Thickness Outer 2.9 2.9 2.9 3.2
Total UDL kN 19:1 100 90 80 65
Manufactured length 600- 1950- 2550- 3150-
150mm increments 1800 2400 3000 3600
Manufactured length 600- 1950- 2550- 3150-
150mm increments 1800 2400 3000 3600
Manufactured length 600- 1950- 2550- 3150-
150mm increments 1800 2400 3000 3600
hnominal
-
8/9/2019 IG intels brochure
41/88
www.iglintels.com
41
For 150mm wide inner leaf blockwork.
For 150mm wide inner leaf blockwork.
For 150mm wide inner leaf blockwork.
hnominal
hnominal
L5/XHD 130 WIL
110-125mmcavityL5/XHD 110 WIL
95
95
95
125
125
125
108
128
148
130-145mmcavity
For cavity widths 110-125mm
For cavity widths 130-145mm
Lintels may be propped to facilitate speedof construction. See Lintel Installationon page 12. Inner leaf block should notoverhang the lintel flange by more than25mm. Blockwork built tight against innerface of the lintel. Place mortar bed on topof blockwork before floor units are laid toprovide even distribution of load.
HEAVIER LOADINGSTables for heavier loads overleaf.
L5/XHD WIL
EXTRA HEAVY DUTY LOADWIDE INNER LEAF
150-165mmcavityL5/XHD 150 WIL For cavity widths 150-165mm
102mm
Ou
ter
Lea
f
150mm
Inner
Lea
f
hnominal
Height h 235 235 235 235
Thickness Inner 5.0 5.0 5.0 5.0
Thickness Outer 2.9 2.9 2.9 3.2
Total UDL kN 19:1 100 90 80 65
Height h 235 235 235 235
Thickness Inner 5.0 5.0 5.0 5.0
Thickness Outer 2.9 2.9 2.9 3.2
Total UDL kN 19:1 100 90 80 65
Height h 235 235 235 235
Thickness Inner 5.0 5.0 5.0 5.0
Thickness Outer 2.9 2.9 2.9 3.2
Total UDL kN 19:1 100 90 80 65
Manufactured length 600- 1950- 2550- 3150-
150mm increments 1800 2400 3000 3600
Manufactured length 600- 1950- 2550- 3150-
150mm increments 1800 2400 3000 3600
Manufactured length 600- 1950- 2550- 3150-
150mm increments 1800 2400 3000 3600
-
8/9/2019 IG intels brochure
42/88
-
8/9/2019 IG intels brochure
43/88
www.iglintels.com
43
368
207
348
207
328
207
L6/130 WIL
110-125mmcavityL6/110 WIL
130-145mmcavity
For cavity widths 110-125mm
For cavity widths 130-145mm
To achieve loading figures lintelmust be laterally restrained.Lintels may be propped tofacilitate speed of construction.See Lintel Installation on page 12.
L6/ WIL
EXTREME LOADWIDE INNER LEAF
150-165mmcavityL6/150 WIL For cavity widths 150-165mm
102mm
Ou
ter
Lea
f
150mm
Inner
Lea
f
End Bearing 200 200 200 200 200 200
Total UDL kN 19:1 80 70 62 55 45 40
End Bearing 200 200 200 200 200 200
Total UDL kN 19:1 80 70 62 55 45 40
End Bearing 200 200 200 200 200 200
Total UDL kN 19:1 80 70 62 55 45 40
Manufactured length (mm) 600- 5200 5400 5800 6200 6600
to customer requirements 4800
Manufactured length (mm) 600- 5200 5400 5800 6200 6600
to customer requirements 4800
Manufactured length (mm) 600- 5200 5400 5800 6200 6600
to customer requirements 4800
For 150mm wide inner leaf blockwork.
For 150mm wide inner leaf blockwork.
For 150mm wide inner leaf blockwork.
-
8/9/2019 IG intels brochure
44/88
LINTELGUIDE
44
If lintels are required to carryloads not indicated on theload tables, please contactIGs Technical Department.
Fax Back Enquiry Forms are
also available for download.
LINTEL HOTLINE
01633 486486
www.iglintels.com/technical
IG Fastrack CAD Databaseisaccessible from iglintels.com
95 21048
hnominal
Cavity widths90-105mmL1/S 100 WIL 215
DAMP PROOFING Provide a damp proof course over all lintels. Please see IG installation details for guidance on page 12.
Wide Inner Leaf - Cavity Wall
Standard Load
Cavity widths from50mm to 165mm
OUTER LEAF INNER LEAF
102mm 215mm
90-105mmcavity
Cavity widths50-65mm
Cavity widths70-85mm 70-85mmcavity
L1/S 50 WIL 215
L1/S 75 WIL 215
50-65mmcavity
Height h 78 104 121 146 171 209
Thickness 2.5 2.5 2.5 2.5 2.5 2.9
Total UDL kN 3:1 25 25 25 30 35 40
Total UDL kN 19:1 20 20 20 25 30 35
Fin Height 100 120 140 175 225 225
Height h 100 117 142 168 204
Thickness 2.5 2.5 2.5 2.5 2.9
Total UDL kN 3:1 25 25 30 35 40
Total UDL kN 19:1 20 20 25 30 35
Fin Height 120 140 175 225 225
Height h 90 105 138 163 171 200
Thickness 2.5 2.5 2.5 2.5 2.5 2.9
Total UDL kN 3:1 25 25 30 35 35 40
Total UDL kN 19:1 20 20 25 30 30 35
Fin Height 100 120 175 225 225 225
Manufactured length 600- 1350- 1650- 1950- 2250- 3150-
150mm increments 1200 1500 1800 2100 3000 4050
Manufactured length 600- 1800 1950- 2250- 3150-
150mm increments 1650 2100 3000 4050
Manufactured length 600- 1500- 1800- 2250- 2850- 3150-
150mm increments 1350 1650 2100 2700 3000 4050
For 215mm wide inner leaf blockwork.
For 215mm wide inner leaf blockwork.
For 215mm wide inner leaf blockwork.
95
95
210
210
68
88
h
nominal
hno
minal
-
8/9/2019 IG intels brochure
45/88
www.iglintels.com
45
L1/S 130 WIL 215
L1/S 110 WIL 215 Cavity widths110-125mm
Cavity widths130-145mm
Lintels may be propped to facilitatespeed of construction. See LintelInstallation on page 12. Inner leaf
block should not overhang the lintelflange by more than 25mm.
HEAVIER LOADINGS Tables for heavier loads overleaf.
L1/S WIL 215
STANDARD LOADWIDE INNER LEAF
L1/S 150 WIL 215 Cavity widths150-165mm
102mm
Ou
ter
Lea
f
215mm
Inner
Lea
f
95
95
95
210
210
210
108
128
148
110-125mmcavity
130-145mmcavity
Height h 95 121 145 195 195
Thickness 2.5 2.5 2.5 2.5 2.9
Total UDL kN 3:1 25 25 30 35 40
Total UDL kN 19:1 20 20 25 30 35
Fin Height 120 140 175 225 225
Height h 103 128 190 190 190
Thickness 2.5 2.5 2.5 2.5 2.9
Total UDL kN 3:1 25 25 30 35 40
Total UDL kN 19:1 20 20 25 30 35
Fin Height 120 140 175 225 225
Height h 103 128 190 190 190
Thickness 2.5 2.5 2.5 2.5 2.9
Total UDL kN 3:1 25 25 30 35 40
Total UDL kN 19:1 20 20 25 30 35
Fin Height 120 140 175 225 225
Manufactured length 600- 1650- 1950- 2250- 3150-
150mm increments 1500 1800 2100 3000 4050
Manufactured length 600- 1650- 1950- 2250- 3150-
150mm increments 1500 1800 2100 3000 4050
Manufactured length 600- 1650- 1950- 2250- 3150-
150mm increments 1500 1800 2100 3000 4050
For 215mm wide inner leaf blockwork.
For 215mm wide inner leaf blockwork.
For 215mm wide inner leaf blockwork.
hnominal
h
nominal
hnom
inal
150-165mmcavity
-
8/9/2019 IG intels brochure
46/88
-
8/9/2019 IG intels brochure
47/88
-
8/9/2019 IG intels brochure
48/88
-
8/9/2019 IG intels brochure
49/88
www.iglintels.com
49
L6/130 WIL 215
L6/110 WIL 215 Cavity widths110-125mm
Cavity widths130-145mm
To achieve loading figures lintelmust be laterally restrained.Lintels may be propped tofacilitate speed of construction.See Lintel Installation on page 12.
L6/ WIL 215
EXTREME LOADWIDE INNER LEAF
L6/150 WIL 215 Cavity widths150-165mm
102mm
Ou
ter
Lea
f
215mm
Inner
Lea
f
110-125mmcavity
130-145mmcavity
150-165mmcavity
For 215mm wide inner leaf blockwork.
For 215mm wide inner leaf blockwork.
For 215mm wide inner leaf blockwork.
End Bearing 200 200 200 200 200 200
Total UDL kN 19:1 80 70 62 55 45 40
End Bearing 200 200 200 200 200 200
Total UDL kN 19:1 80 70 62 55 45 40
End Bearing 200 200 200 200 200 200
Total UDL kN 19:1 80 70 62 55 45 40
Manufactured length (mm) 600- 5200 5400 5800 6200 6600
to customer requirements 4800
Manufactured length (mm) 600- 5200 5400 5800 6200 6600
to customer requirements 4800
Manufactured length (mm) 600- 5200 5400 5800 6200 6600
to customer requirements 4800
413
433
453
207
207
207
-
8/9/2019 IG intels brochure
50/88
LINTELGUIDE
50
If lintels are required to carryloads not indicated on theload tables, please contactIGs Technical Department.
Fax Back Enquiry Forms are
also available for download.
LINTEL HOTLINE
01633 486486
www.iglintels.com/technical
IG Fastrack CAD Databaseisaccessible from iglintels.com
120
120
120
100
100
100
h
nominal
hnominal
68
88
48
hnominal
For cavity widths 90-105mmL1/S 100 WOL
DAMP PROOFINGProvide a damp proof course over all lintels. Please see IG installation details for guidance on page 12.
Wide Outer Leaf - Cavity Wall
Standard Load
Cavity widths from50mm to 165mm
OUTER LEAF INNER LEAF
125mm - 150mm 100mm
90-105mmcavity
For cavity widths 50-65mm
For cavity widths 70-85mm 70-85mmcavity
L1/S 50 WOL
L1/S 75 WOL
50-65mmcavity
For 150mm wide outer leaf blockwork/stonework.
For 150mm wide outer leaf blockwork/stonework.
For 150mm wide outer leaf blockwork/stonework.
Height h 110 122 172 200 200 200
Thickness 2.5 2.5 2.5 2.9 2.9 3.2
Total UDL kN 3:1 14 15 23 30 32 30
Total UDL kN 19:1 11 13 18 22 30 26
Height h 106 118 168 192 192 192
Thickness 2.5 2.5 2.5 2.9 2.9 3.2
Total UDL kN 3:1 14 15 23 30 32 30
Total UDL kN 19:1 11 13 18 22 30 26
Height h 93 110 162 188 188 188
Thickness 2.5 2.5 2.5 2.9 2.9 3.2
Total UDL kN 3:1 14 15 23 30 32 30
Total UDL kN 19:1 11 13 18 22 30 26
Manufactured length 600- 1500- 1800- 2250- 2850- 3150-
150mm increments 1350 1650 2100 2700 3000 3600
Manufactured length 600- 1500- 1800- 2250- 2850- 3150-
150mm increments 1350 1650 2100 2700 3000 3600
Manufactured length 600- 1500- 1800- 2250- 2850- 3150-
150mm increments 1350 1650 2100 2700 3000 3600
-
8/9/2019 IG intels brochure
51/88
www.iglintels.com
51
For cavity widths 150-165mm
L1/S 130 WOL
110-125mmcavityL1/S 110 WOL
130-145mmcavity
For cavity widths 110-125mm
For cavity widths 130-145mm
To achieve loading figures lintelmust be built in with blockworkas shown. Maximum overhang
of 30mm on outer leaf. Lintelsmay be propped to facilitatespeed of construction. See LintelInstallation on page 12.
HEAVIER LOADINGSTables for heavier loads overleaf.
L1/S WOL
STANDARD LOADWIDE OUTER LEAF
150-165mmcavityL1/S 150 WOL
140mm
Ou
ter
Lea
f
100mm
Inner
Lea
f
120
120
120
100
100
100
hnominal
108
128
148
h
nominal
hnominal
For 150mm wide outer leaf blockwork/stonework.
For 150mm wide outer leaf blockwork/stonework.
For 150mm wide outer leaf blockwork/stonework.
Height h 95 107 142 185 185 185
Thickness 2.5 2.5 2.5 2.9 3.2 3.2
Total UDL kN 3:1 14 15 23 30 32 30
Total UDL kN 19:1 11 13 18 22 30 26
Height h 90 118 178 178 178 178
Thickness 2.5 2.5 2.5 2.9 3.2 3.2
Total UDL kN 3:1 14 15 23 30 32 30
Total UDL kN 19:1 11 13 18 22 30 26
Height h 95 107 168 168 168 168
Thickness 2.5 2.5 2.5 2.9 3.2 3.2
Total UDL kN 3:1 14 15 23 30 32 30
Total UDL kN 19:1 11 13 18 22 30 26
Manufactured length 600- 1500- 1800- 2250- 2850- 3150-
150mm increments 1350 1650 2100 2700 3000 3600
Manufactured length 600- 1500- 1800- 2250- 2850- 3150-
150mm increments 1350 1650 2100 2700 3000 3600
Manufactured length 600- 1500- 1800- 2250- 2850- 3150-
150mm increments 1350 1650 2100 2700 3000 3600
-
8/9/2019 IG intels brochure
52/88
-
8/9/2019 IG intels brochure
53/88
www.iglintels.com
53
Cavity widths150-165mm
L1/HD 130 WOL
110-125mmcavityL1/HD 110 WOL
130-145mmcavity
Cavity widths110-125mm
Cavity widths130-145mm
To achieve loading figures lintelmust be built in with blockworkas shown. Maximum overhang
of 30mm on outer leaf. Lintelsmay be propped to facilitatespeed of construction. See LintelInstallation on page 12.
HEAVIER LOADINGSTables for heavier loads overleaf.
L1/HD WOL
HEAVY DUTY LOADWIDE OUTER LEAF
150-165mmcavityL1/HD 150 WOL
For 150mm wide outer leaf blockwork/stonework.
For 150mm wide outer leaf blockwork/stonework.
For 150mm wide outer leaf blockwork/stonework.
140mm
Ou
ter
Lea
f
100mm
Inner
Lea
f
120
120
120
100
100
100
hnominal
108
128
148
h
nominal
hnominal
Height h 112 132 182 182
Thickness 2.9 2.9 2.9 3.2
Total UDL kN 3:1 20 30 30 36
Total UDL kN 19:1 17 25 25 32
Height h 103 143 178 178
Thickness 2.9 2.9 2.9 3.2
Total UDL kN 3:1 20 30 30 36
Total UDL kN 19:1 17 25 25 32
Height h 113 148 168 168
Thickness 2.9 2.9 2.9 3.2
Total UDL kN 3:1 20 30 30 36
Total UDL kN 19:1 17 25 25 32
Manufactured length 600- 1500- 1950- 2250-
150mm increments 1350 1800 2100 2700
Manufactured length 600- 1500- 1950- 2250-
150mm increments 1350 1800 2100 2700
Manufactured length 600- 1500- 1950- 2250-
150mm increments 1350 1800 2100 2700
-
8/9/2019 IG intels brochure
54/88
LINTELGUIDE
54
If lintels are required to carryloads not indicated on theload tables, please contactIGs Technical Department.
Fax Back Enquiry Forms are
also available for download.
LINTEL HOTLINE
01633 486486
www.iglintels.com/technical
IG Fastrack CAD Databaseisaccessible from iglintels.com
Height h 161 196 196
Thickness 3.2 3.2 3.2
Total UDL kN 3:1 45 45 50
Total UDL kN 19:1 40 40 40
Height h 155 192 192
Thickness 3.2 3.2 3.2
Total UDL kN 3:1 45 45 50
Total UDL kN 19:1 40 40 40
Height h 165 188 188
Thickness 3.2 3.2 3.2
Total UDL kN 3:1 45 45 50
Total UDL kN 19:1 40 40 40
120
120
120
100
100
100
68
88
48
Cavity widths90-105mmL1/XHD 100 WOL
DAMP PROOFINGProvide a damp proof course over all lintels. Please see IG installation details for guidance on page 12.
Wide Outer Leaf - Cavity Wall
Heavy Duty Load
Cavity widths from50mm to 165mm
OUTER LEAF INNER LEAF
125mm - 150mm 100mm
90-105mmcavity
Cavity widths50-65mm
Cavity widths70-85mm 70-85mmcavity
L1/XHD 50 WOL
L1/XHD 75 WOL
50-65mmcavity
For 150mm wide outer leaf blockwork/stonework.
For 150mm wide outer leaf blockwork/stonework.
For 150mm wide outer leaf blockwork/stonework.
Manufactured length 600- 1650- 1950-
150mm increments 1500 1800 2100
Manufactured length 600- 1650- 1950-
150mm increments 1500 1800 2100
Manufactured length 600- 1650- 1950-
150mm increments 1500 1800 2100
hnominal
hnominal
hnominal
-
8/9/2019 IG intels brochure
55/88
-
8/9/2019 IG intels brochure
56/88
-
8/9/2019 IG intels brochure
57/88
www.iglintels.com
57
110-125mmcavity
130-145mmcavity
Cavity widths110-125mm
Cavity widths130-145mm
To achieve loading figures lintel must bebuilt in with blockwork as shown. Maximumoverhang of 30mm on outer leaf. Ensure
all perpendicular and horizontal joints arefilled with mortar. Place mortar bed on topof blockwork before floor units are laid toprovide even distribution of load. Lintelsmay be propped to facilitate speed ofconstruction. See Lintel Installation on page 12.
HEAVIER LOADINGSTables for heavier loads overleaf.
L5/ WOL
EXTRA HEAVY DUTY LOADWIDE OUTER LEAF
150-165mmcavity
L5/110 WOL
L5/130 WOL
L5/150 WOL
For 150mm wide outer leaf blockwork/stonework.
For 150mm wide outer leaf blockwork/stonework.
For 150mm wide outer leaf blockwork/stonework.
140mm
Ou
ter
Lea
f
100mm
Inner
Lea
f
120
120
120
100
100
100
108
128
148
hnominal
hnominal
hnominal
Height h 229 229 229 229 229
Thickness 2.9 2.9 2.9 3.2 3.2
Total UDL kN 19:1 70 60 50 45 40
Height h 229 229 229 229 229
Thickness 2.9 2.9 2.9 3.2 3.2
Total UDL kN 19:1 70 60 50 45 40
Height h 229 229 229 229 229
Thickness 2.9 2.9 2.9 3.2 3.2
Total UDL kN 19:1 70 60 50 45 40
Manufactured length 600- 1650- 2250- 3150- 4200-
150mm increments 1500 2100 3000 4050 4800
Manufactured length 600- 1650- 2250- 3150- 4200-
150mm increments 1500 2100 3000 4050 4800
Manufactured length 600- 1650- 2250- 3150- 4200-
150mm increments 1500 2100 3000 4050 4800
Cavity widths150-165mm
-
8/9/2019 IG intels brochure
58/88
LINTELGUIDE
58
If lintels are required to carryloads not indicated on theload tables, please contactIGs Technical Department.
Fax Back Enquiry Forms are
also available for download.
LINTEL HOTLINE
01633 486486
www.iglintels.com/technical
IG Fastrack CAD Databaseisaccessible from iglintels.com
L5/XHD 100 WOL
120
120
120
100
100
100
68
88
48
Cavity widths90-105mm
DAMP PROOFINGProvide a damp proof course over all lintels. Please see IG installation details for guidance on page 12.
Wide Outer Leaf - Cavity Wall
Extra Heavy Duty Load
Cavity widths from50mm to 165mm
OUTER LEAF INNER LEAF
125mm - 150mm 100mm
90-105mmcavity
Cavity widths50-65mm
Cavity widths70-85mm 70-85mmcavity
L5/XHD 50 WOL
L5/XHD 75 WOL
50-65mmcavity
For 150mm wide outer leaf blockwork/stonework.
For 150mm wide outer leaf blockwork/stonework.
For 150mm wide outer leaf blockwork/stonework.
hnominal
hnominal
hnominal
Height h 235 235 235 235
Thickness Inner 5.0 5.0 5.0 5.0
Thickness Outer 2.9 2.9 2.9 3.2
Total UDL kN 19:1 100 90 80 65
Height h 235 235 235 235
Thickness Inner 5.0 5.0 5.0 5.0
Thickness Outer 2.9 2.9 2.9 3.2
Total UDL kN 19:1 100 90 80 65
Height h 235 235 235 235
Thickness Inner 5.0 5.0 5.0 5.0
Thickness Outer 2.9 2.9 2.9 3.2
Total UDL kN 19:1 100 90 80 65
Manufactured length 600