IMAGING IBRIDO E MOLECOLARELa nuova diagnostica per immagini
Vincenzo Positano
L’imaging rappresenta la base di conoscenza per le applicazioni di realtàvirtuale in medicina e chirurgia
Courtesy of Ing. Lucio de Paolis
Alta risoluzione spaziale e temporale: qualità dell’ambiente virtuale
Sensitività diagnostica: identificazione dell’oggetto di interesse
Imaging medico: Compromesso tra risoluzione e sensitività
Imaging medico: Modalità“anatomiche” vs. modalità“funzionali” o “metaboliche”
Problema della registrazione o fusione di immagini
Santarelli et al. IEEE Trans Inf. Tech Biomed 1997
Santarelli et al. IEEE Trans Inf. Tech Biomed 2000
2002: REGISTRATION OF CMR SERIES
Positano et al. EJASP 2003 Positano et al. Heart 2005
Positano et al. JCMR 2005
2005: MYOCARDIAL NECROSIS BY CMR AND SPECT
1995 PACOMIPMRI - SPECT
CONTRACTILITY BY MRI
NH3 by PET
FDG
+
M. Marinelli et al. ISMRM 2009
Giuseppe L’Abbate
Imaging ibrido: software registration and fusion
Macchine ibride: acquisizione contemporanea di immagini anatomiche e funzionali
Soluzioni: imaging ibrido e nuovi traccianti molecolari
Imaging molecolare: nuovi traccianti per realizzare l’imaging molecolare in modalità tradizionalmente “anatomiche”
Soluzioni: imaging ibrido e nuovi traccianti molecolari
Courtesy of GE Medical
Non solo ricerca…
Courtesy of GE Medical
Non solo ricerca…
La registrazione
hardware non esclude
la registrazione
software:
gli scanner ibridi
spesso necessitano di
una registrazione
software (soprattutto
temporale) dei dati.0 t
LV long axis (LA)
short axis (SA)slice planes
La registrazione hardware si avvale si scanner ibridi, sviluppati con
l’obiettivo di realizzare immagini anatomiche e funzionali registrate
in partenza, utilizzando lo stesso scanner per entrambe le modalità e
con il paziente nella stessa posizione.
Imaging ibrido: scanner ibridi (hardware fusion)
QS
RT P
end-diastole(ED)
end-systole (ES)
systole diastole
P
diastoleQ
R
Multi-slice, multi-phase ECG gated MR Image acquisition
→ Breathold acquisition when possible
PET/CT
SPECT/CT
PET-CT, SPECT-CT: la pratica clinica
Invention of the Year in 2000 by Time Magazine
Censimento PET-AIMN 2006-2007
PET/CT & SPECT/CT
La CT nei sistemi ibridi PET o SPECT può essere usata per:
Correzione per l’attenuazione dei raggi gamma
Valutazione del calcio nelle coronariche
Valutazione angiografica delle coronarie
Aumento della specificità nella valutazione delle lesioni coronariche
Il movimento del paziente o i movimenti dovuti al respiro possono causare artefatti, nonostante esistano protocolli che ne limitano gli artefatti.
J Nucl Med 2008; 49:1305–1319
PET-CT, SPECT-CT: la pratica clinica
Trasformazione rigida manuale del volume PET sul volume CT
Fusione di immagini volumetriche: il colore delle superfici è generato a partire dalla mappa di perfusione.
Visualizzazione 3D dell’albero coronarico
Visualizzazione 3D integrata
PET-CT, SPECT-CT: imaging cardiovascolare
Courtesy of Dr Danilo Neglia, Fondazione “G Monasterio” and IFC_CNR, Pisa
Common sliding patient table provides path toMR-guided intervention
XMR: hybrid X-ray/MR imaging
During Interventional CMR, traversing complex coronary lesions
require delicate guidewire and device manipulation, and currently this
is conducted under XRF (X-Ray Fluoroscopy) guidance with device
imaging at 200 μm spatial resolution in a 512–1024 square pixel matrix
at 15 to 60 frames/second.
There was a substantial reduction in x-ray dose compared to traditional
procedures. The availability of anatomical and functional information
from MR is of great benefit.
fluoroscopy offers very high spatial and temporal resolution and is excellent for guidingand deploying devices. MRI offers tomographic imaging with complete freedom of planeorientation, outstanding soft tissue discrimination, and the ability to portray physiological responsesduring treatment.
X-ray/MR imaging
Prototipo di Tomografo ibrido MRI/PET
MRI/PETHardware RegistrationMackewn et al., Description and preliminary results of an MR-Compatible PET system for molecular imaging studies, ISMRM-ESMRMB, 2007, ISSN 1545-4436
La compatibilità dei detettori PET con gli alti campi magnetici della risonanza è ancora problematica. La limitazione intrinseca del diametro della MRI è un altro problema rilevante
Attualmente esistono prototipi per studi su animale
Imaging molecolare: nuovi traccianti
Realizzare l’imaging molecolare e metabolico attraverso
traccianti innovativi in modalità ad alta risoluzione spaziale e
temporale (US e MRI)
Imaging molecolare: nuovi traccianti 13C Hyperpolarized MRS
Aumenta la percentuale di polarizzazione (103-104)
−+
−+
+−
=NNNNP P = 5 x 10-6 for H-1 at 1.5T
Hypersense (Oxford Instruments) FTGM Pisa
Imaging molecolare: nuovi traccianti 13C Hyperpolarized MRS
Costo elevatoUna dose / hEmivita breve (< 60 sec)
Nuove sequenzeNuove bobineNuovi algoritmi di analisi………
Imaging molecolare: nuovi traccianti 13C Hyperpolarized MRS
Metabolismo del piruvato
Imaging molecolare: nuovi traccianti 13C Hyperpolarized MRS
Imaging molecolare: nuovi traccianti 13C Hyperpolarized MRS
Rat 26 03 09
0,0E+00
2,0E+09
4,0E+09
6,0E+09
8,0E+09
1,0E+10
1,2E+10
1,4E+10
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31
time (sec)
Am
plitu
de
Pyruvate/10LactatePyruvate HydrateAlanineBicarbonate
CSI – metabolic maps
Pyruvate
Pig #4
Conclusioni
Le nuove apparecchiature mettono o metteranno in tempi brevi a disposizione set di dati anatomici e funzionali intrinsecamente registrati spazialmente, riducendo il problema derivante dall’uso di algoritmi di registrazione in post-processing
E’ necessario lo sviluppo di metodologie di visualizzazione e navigazione in modo da integrare le informazioni disponibili.
Resta in gran parte aperto il problema della registrazione temporale