Internet Contact Details Before using the product, please check the guide pages at the front of this catalog. http://www.daikinpmc.com/en/ For latest information, PDF catalogs and operation manuals OIL COOLING EQUIPMENT O O-13 Super Unit Multi-stage pressure/flow rate control (16 P-Q control setting patterns) The force (pressure) of the actuator (cylinder), and the speed (flow rate) can be controlled as sixteen pressure/flow rate (P/Q) combinations. The proportional control valve and proportional pressure control valve, which are utilized in conventional actuator circuits, can be omitted. The pressure and flow rate can be set from the controllerʼ s operation panel, and sixteen different pressure/flow rate settings can be selected using external input signals. Switching from flow rate control to pressure control is handled autonomously at the Super Unit. (For example, there is a switch from flow rate to pressure control at the cylinder stroke end.) The ON/OFF control of the solenoid valve for cylinder operation requires operation at the machine. There is smooth switching between force (pressure) and speed (flow rate). Once acceleration time and deceleration time parameters are registered, the force or speed can be changed gradually during a pressure/flow rate setting change. Maintenance/Management Function (Hybrid-Win) Internal data of the Super Unit can be obtained by using PC connected to the unit. The pressure, flow rate, and other internal data of the inverter can be monitored and displayed in the form of graphs. This facilitates operation checks during test runs, adjustment of parameters such as time constants, and troubleshooting. The time required for setting can be slashed by editing the parameter settings on the PC and writing them to the unit in a batch. The ability to read and save settings facilitates management. Functions 16 PQ Featured with standard models Featured with standard models PC tool Supported Excluded from high-efficiency motor regulations The high-efficiency motor regulations took effect in Japan from April 2015. These regulations apply to the hydraulic units equipped with induction motors. This Super Units will be exempted from these regulations by adopting a special- design inverter motor. 50% reduction in power consumption (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system with inverter technologies provides a high energy-saving ratio of 50%. Low noise level 60 dB(A) An operating noise level of 60 dB (A) has been achieved with double pump specifications at the holding pressure of 20.6 MPa. The noise level does not exceed 73 dB (A) even over the full operating range. Conforming to CE standards All models conform to the machinery directive, EMC directive, and low voltage directive to facilitate CE approval of the main machine. Restricted oil temperature rise Motor speed control also leads to restriction of the oil temperature rise. This inhibits deterioration of the hydraulic oil, which helps to reduce costs and prevent environmental pollution. In addition to improving the working environment, it can also be expected to generate further energy savings by lowering the load on air conditioning equipment. Features Advantages of using hybrid hydraulic units (1) Eliminates motor replacement work for each destination (2) Eliminates machine design change in accordance with amendment of the regulations. (3) Reduces design changes to spare parts, and saves maintenance time.

Upload: others

Post on 16-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

OIL

CO

OLI

NG

EQ

UIP

ME

NT

O

O-13

Super Unit

Multi-stage pressure/flow rate control (16 P-Q control setting patterns)The force (pressure) of the actuator (cylinder), and the speed (flow rate) can be controlled as sixteen pressure/flow rate (P/Q) combinations. ・ The proportional control valve and proportional pressure control valve, which are utilized in conventional actuator

circuits, can be omitted. The pressure and flow rate can be set from the controllerʼ s operation panel, and sixteen different pressure/flow rate settings can be selected using external input signals.

・ Switching from flow rate control to pressure control is handled autonomously at the Super Unit. (For example, there is a switch from flow rate to pressure control at the cylinder stroke end.)

・ The ON/OFF control of the solenoid valve for cylinder operation requires operation at the machine.

There is smooth switching between force (pressure) and speed (flow rate).・ Once acceleration time and deceleration time parameters are registered, the force or speed can be changed gradually

during a pressure/flow rate setting change. Maintenance/Management Function (Hybrid-Win)

Internal data of the Super Unit can be obtained by using PC connected to the unit.

• The pressure, flow rate, and other internal data of the inverter can be monitored and displayed in the form of graphs. This facilitates operation checks during test runs, adjustment of parameters such as time constants, and troubleshooting.

• The time required for setting can be slashed by editing the parameter settings on the PC and writing them to the unit in a batch. The ability to read and save settings facilitates management.

Functions

16PQ

4PQ

Com. Hyb.Win

Featured with standard models

Featured with standard models

P C t o o l

Supported

Excluded from high-efficiency motor regulations The high-efficiency motor regulations took effect in Japan from April 2015.These regulations apply to the hydraulic units equipped with induction motors. This Super Units will be exempted from these regulations by adopting a special-design inverter motor.

50% reduction in power consumption (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system with inverter technologies provides a high energy-saving ratio of 50%.

Low noise level 60 dB(A)An operating noise level of 60 dB (A) has been achieved with double pump specifications at the holding pressure of 20.6 MPa. The noise level does not exceed 73 dB (A) even over the full operating range.

Conforming to CE standardsAll models conform to the machinery directive, EMC directive, and low voltage directive to facilitate CE approval of the main machine.

Restricted oil temperature riseMotor speed control also leads to restriction of the oil temperature rise.This inhibits deterioration of the hydraulic oil, which helps to reduce costs and prevent environmental pollution. In addition to improving the working environment, it can also be expected to generate further energy savings by lowering the load on air conditioning equipment.

Features

Advantages of using hybrid hydraulic units

(1) Eliminates motor replacement work for each destination(2) Eliminates machine design change in accordance with amendment of

the regulations.(3) Reduces design changes to spare parts, and saves maintenance time.

Page 2: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

O-14

Nomenclature

SUT 03 S 15 07 - 30 - - - 1 2 3 4 5 6 7 8 9

SUT 00 S 110 07 - 30 - - 1 2 3 4 5 6 7 8

Equivalent to 2.2 to 7.0 kW

Equivalent to 11 kW

1 Model No.SUT: SUT series

7 Function Option

Design No.Incremented at model changes

0003061016

:::::

Tankless type30 L60 L100 L160 L

2 Tank capacity

4 Pump discharge rate 6

5 Maximum operating pressure

8 9 Non-standard No.1530406080

:::::

1530406080

L/minL/minL/minL/minL/min

07101621

::::

MPaMPa,16.0 MPaMPa

C

P

:

:

With communication function (RS232C)With analog input function

01

Hardware OptionUnit cover (except for 30 L tank)

02

03 DCL (except for 7 kW)

04

05 Water fill test compliant tank06 Water leak test compliant tank07 Level switch08 Temperature switch09 Thermometer10 Micro separator11 Combination of 1 to 10 above...

DS

::

Double pump typeSingle pump type

3 Pump type

7.010.015.720.6

Controller cover (except for 7 kW and higher)

Separation of power supplies for power and control lines

N: Without control systemA: With control system

1 Model No.SUT : SUT series

7 Function Option

2 Tank capacity4 Pump discharge rate Design No.

Incremented at model changes6

5 Maximum operating pressure 8 N: Without control systemA: With control system

Non-standard No.C

P

:

:

With communication function (RS232C)With analog input function

DS

::

Double pump typeSingle pump type

3 Pump type

00 : Tankless type110 : 110 L/min

0721

: :

7.020.6

MPaMPa

C: With communication function (RS232C) Remote control and setting changes are possible through RS232C serial communication.

01: Unit cover The cover protects the controller unit and piping.

02: Controller cover The metal cover protects the controller unit.

03: With DCL (DC reactor) Appropriate when it is necessary to improve the power factor or reduce the harmonics of the power supply This is provided as an option for compact models of 5 kW and smaller. For models of 7 kW and larger, it is installed as standard.

04: Separate power supplies for power system and control system When an error occurs, only the main power supply is shut down and control power supply continues to carry current, thereby enabling the alarm code and internal status on occurrence of an error to be checked on the operation panel or through serial communication.

05: Water fill test compliant tank, 06 : Water leak test compliant tank We implement the water fill test that is one of the criteria for compliance with Japanese Fire Services Act, and the water leak test that is Daikin's own criterion. Products are shipped with a test-compliance name plate affixed, and with a pass certificate. (A water fill test compliant tank is not equivalent to a Fire Services Act-compliant tank.)

07: Level switch, 08: Temperature switch, 09: Thermometer, 10: Microseparator These accessories for fitting to the tank are provided as options. The accessories can also be purchased as optional parts.

Optional function

Hardware option

16PQ

4PQ

Com. Hyb.Win

P: With analog input function Enables linear control of pressures and flow rates as required.

Analog

Page 3: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

OIL

CO

OLI

NG

EQ

UIP

ME

NT

O

O-15

List of Models with Options Installed

Model code

SUT00S1507-30

Single pump

SUT00S3007-30

SUT00S1510-30

SUT00S4007-30

SUT00S3010-30

SUT00S1516-30

SUT00S3016-30

SUT00S6007-30

SUT00D4016-30

Double pump

SUT03S1507-30

SUT03S3007-30

SUT03S1510-30

SUT03S4007-30

SUT03S3010-30

SUT03S1516-30

SUT06S3016-30

SUT06S6007-30

SUT06D4016-30

SUT10D6021-30

SUT16D8021-30

SUT06D6021-30

SUT10D8021-30

SUT00S8007-30

SUT10S8007-30

SUT00D6021-30

SUT00D8021-30

C P

Unit cover(01)

Controller cover(02)

DCL(03)

Function Option Hardware Option

* Tank inspections : Water fill test compliant tank (05), water leak test compliant tank (06) Unit accessories : Level switch (07), temperature switch (08), thermometer (09), microseparator (10)

Setting available − No setting

Motor capacity

Separation of power supplies for power and

control lines (04)

Tank inspection / Unit accessory

(*)

Equivalent to 2.2 kW

Equivalent to 2.8 kW

Equivalent to 3.7 kW

Equivalent to 5.0 kW

Equivalent to 7.0 kW

Equivalent to 3.7 kW

Equivalent to 5.0 kW

Equivalent to 7.0 kW

Pump specifications

Page 4: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

O-16

Specifications

Pressure – Flow rate characteristics (Example)Maximum operating pressure 7 MPa

Maximum discharge rate 15/30 L/minModel code

SUTS1507-30SUTS3007-30

Super Unit [Single pump type]

Flow

rate

(L/m

in)

Pressure (MPa)

10

20

30

40

60

80

90

100

110

50

70

2 4 6 8 10 12 14 161 3 5 7 9 11 13 15

SUTS407

SUTS3007

SUTS1507

SUTS6007

SUTS8007

SUTS11007

SUTS4007

SUTS3007

SUTS1507

SUTS6007

SUTS8007

SUTS11007

* Operating flow rate at the maximum pressure in continuous operation:SUTS1507: 3 L/min maximumSUTS3007: 5 L/min maximum

* The graph shows actual flow rates (representative values).

SUT00S 1507-30

SUT00S 3007-10-F

Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.*3: The unit incorporates a safety valve.*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics” and the description of how to select a unit in the separate catalog for Super Units. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.

Model SUT03S 15L07-10-F

External input signal5 channels

59

Motor pump/unitPower supply

AC3 φ 200 V (50 Hz)Rated current

(A)

Usable oil *2

Others

Operating conditions

Operating hydraulic oil temperature

Operating ambient temperature

Storage ambient temperature

Operating ambient humidity

Installation site

AC3 φ 200 V (60 Hz)

AC3 φ 220 V (60 Hz)

Power source breaker setting (A)

Mass (kg)

15

Standard coating color

Pump unit

Maximum discharge rate (Theoretical value; L/min) *1

Motor capacity (Equivalent kW)Motor capacity

Maximum operating pressure (MPa)

Operating flow rate adjustment range (L/min)

Operating pressure adjustment range (MPa)

11.5

11.3

10.6

Tank capacity (L)

15.4

15.1

13.8

20

11.5

11.3

10.6

15

15.4

15.1

13.8

20

37 39

28.5

3.5 to 28.5

15.2

2.5 to 15.2

Equivalent to 2.8 kWEquivalent to 2.2 kW

1.5 to 7.0

7.0

28.5

3.5 to 28.5

15.2

2.5 to 15.2

Equivalent to 2.8 kWEquivalent to 2.2 kW

Contact outputExternal

output signalDigital output

SUT03S 30L07-10-F

3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)

0 to 60°C (Recommended operating temperature range: 15 to 50°C)

− 30

0 to 40°C

−20 to 60°C

85% RH maximum (No condensation)

Indoors (Be sure to secure the unit with bolts.)

Ivory white (Munsell code 5Y7.5/1)

Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel

Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil• Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum

• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.• Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.

To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.• Be sure to connect the ground terminal.

1 channel (1 common contact), dry contact, Contact capacity: DC 30 V, 0.5 A (Resistance load)

2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel

Tankless type Unit type

Tankless type Unit type

Page 5: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

OIL

CO

OLI

NG

EQ

UIP

ME

NT

O

O-17

External dimension diagram

Tankless type

Unit type

8 1

Unit nameplate

φ21 hole(Signal cable port)(Power cable port)

φ28 hole

30 284 30

344

45(4

21)

(Fitted with a vinyl cap at shipment)

(Fitted with a vinyl cap at shipment)

(83)

(109

)

(246

)

(260

)

3046030

520

45(2

20)

(466

)

Rc⅜

Suction port: G¾

(Fitted with a vinyl cap at shipment)

(87)

1549015

520

(162

)

(254

)15

314

1534

4

Pressure indication and operation panel Rc⅜

3

1-2

DR

(Fitted with a vinyl cap at shipment)Rp¾ (above oil level)DR

P

(Fitted with a vinyl cap at shipment)

Rc⅜P

(Fitted with a vinyl cap at shipment)

Rc1T

170150(75)(175)

132.5 550

Optional port: Rp⅜

Optional port: Rp½

100

(Manifold bracket mount)

50

4-M8

42

92

140

(M12 bolts recommended)4-φ15 holes (for fixing bolts)

(M8 bolts recommended)4-φ10 holes (for fixing bolts)

Pressure indication and display panel

Foundation plate (Option)(E-SUTPLATE-2)

(620)196

(40)(40)

φ21 hole(Signal cable port)

(Power cable port)

φ28 hole

70

20 10 30 30 25

4020

2-M8 (through hole)Tapped holes for mounting the foundation plate (at 4 locations)

700530 8585

Wing bolt for fastening during transportation (at 1 location on the back)(To be removed before operation)

95

419

(516

)

30 LUpper limit (Yellow line)23 LLower limit (Red line)

462

Cleaning port

450500

Oil sampling port/Oil drain port: Rc½

(550)(580)

70 155

(50)

309

6-1

5 4

8

7

Suction air

6-2

1

2

2

1-1

3

Suction air

Safety caution nameplate

Unit nameplate

Safety caution nameplate

Wing bolt for fastening during transportation (at 1 location)(To be removed before operation)

SUT00S1507-30SUT00S3007-30

Part No. Name Quantity

1-1 Inverter driven motor pump 1

1-2 Controller 1

2 AC fan 1

3 Base 1

SUT03S1507-30 SUT03S3007-30

Part No. Name Quantity

1 1

2 1

13

14

15

6-1 1

6-2

7 1

1

Oil tank

Suction strainer

Stop valve

Oil level gauge

Oil filler port with air breather

Inverter driven motor pump

Controller

Oil cooler

AC fan

Page 6: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

O-18

Specifications

Pressure – Flow rate characteristics (Example)Maximum operating pressure 7 MPa

Maximum discharge rate 40 L/minModel code

SUTS4007-30

Super Unit [Single pump type]

Flow

rate

(L/m

in)

Pressure (MPa)

10

20

30

40

60

80

90

100

110

50

70

2 4 6 8 10 12 14 161 3 5 7 9 11 13 15

SUTS307

SUTS6007

SUTS8007

SUTS1507

SUTS11007

SUTS4007

SUTS3007

SUTS6007

SUTS8007

SUTS1507

SUTS11007

SUTS4007

* Operating flow rate at the maximum pressure in continuous operation:8 L/min maximum

* The graph shows actual flow rates (representative values).

SUT00S4007-30

5 channels

64

20

16.1

15.8

14.8

46

1.5 to 7.0

7.0

5.3 to 39.7

Equivalent to 3.7 kW

3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)

− 30

0 to 40°C

0 to 60°C (Recommended operating temperature range: 15 to 50°C)

−20 to 60°C

85% RH max. (No condensation)

Indoors (Be sure to secure the unit with bolts.)

Ivory white (Munsell code 5Y7.5/1)

Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel

Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil• Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 10 • Volumetric water content: 0.1% maximum

• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.• Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.

To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.• Be sure to connect the ground terminal.

1 channel (1 common contact), dry contact, Contact capacity: DC 30 V, 0.5 A (Resistance load)

Tankless type Unit type

39.7

Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.*3: The unit incorporates a safety valve.*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics” and the description of how to select a unit in the separate catalog for Super Units. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.

SUT03S4007-30

2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel

Model

External input signal

Motor pump/unitPower supply

AC3 φ 200 V (50 Hz)Rated current

(A)

Usable oil *2

Others

Operating conditions

Operating hydraulic oil temperature

Operating ambient temperature

Storage ambient temperature

Operating ambient humidity

Installation site

AC3 φ 200 V (60 Hz)

AC3 φ 220 V (60 Hz)

Power source breaker setting (A)

Mass (kg)

Standard coating color

Pump unit

Maximum discharge rate (Theoretical value; L/min) *1

Motor capacity (Equivalent kW)Motor capacity

Maximum operating pressure (MPa)

Operating flow rate adjustment range (L/min)

Operating pressure adjustment range (MPa)

Tank capacity (L)

Contact outputExternal

output signalDigital output

Tankless type Unit type

Page 7: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

OIL

CO

OLI

NG

EQ

UIP

ME

NT

O

O-19

External dimension diagram

Tankless type

Unit type

SUT00S4007-30

1-1 1

1-2 1

2 1

3 1

SUT03S4007-30

Part No. Name Quantity

1 Oil tank 1

2 Suction strainer 1

3 Stop valve 1

4 Oil level gauge 1

5 Oil filler port with air breather 1

6-1 Inverter driven motor pump 1

6-2 Controller

7 Oil cooler 1

8 AC fan 1

1

Safety caution nameplate

(294

)

1535

415

384

(87)1549015

520

30 324 30

384

45(4

21)

(202

)

45

220

(466

)

(108

)

(245

)(2

59)

(83)

30 460 30

520

Rc½P

Rc⅜DR

DR

1-2

1-1

3

2

Rc1T

4-M8

17015077.5177.5

132.5 550

42

92

5010

014

0.5

(620)196

(40) (40)

2595

419

(516

)

70

20 10 30 30

4020

700530 8585

450500

70 155

(50)

(309

)

(550)(580)

462

6-1

5 4

8

7

6-2

2

1

3

(M8 bolts recommended)4-φ10 holes (for fixing bolts)

(Power cable port)φ28 hole φ21 hole

(Signal cable port)

Wing bolt for fastening during transportation (at 1 location)(To be removed before operation)

Foundation plate (Option)(E-SUTPLATE-2)

30 LUpper limit (Yellow line)23 LLower limit (Red line)

(Fitted with a vinyl cap at shipment)

(Fitted with a vinyl cap at shipment)

Suction port: G¾

(Fitted with a vinyl cap at shipment)

Pressure indication and operation panel

(Fitted with a vinyl cap at shipment)Rp¾ (above oil level)

(Fitted with a vinyl cap at shipment)

Rc½P

(Fitted with a vinyl cap at shipment)

Optional port: Rp⅜

Optional port: Rp½

(Manifold bracket mount)

(M12 bolts recommended)4-φ15 holes (for fixing bolts)

Pressure indication and display panel

φ21 hole(Signal cable port)

(Power cable port)

φ28 hole

2-M8 (through hole)Tapped holes for mounting the foundation plate (at 4 locations)

Wing bolt for fastening during transportation (at 1 location on the back)(To be removed before operation)

Cleaning port

Oil sampling port/Oil drain port: Rc½

Suction air

Suction air

Safety caution nameplate

Unit nameplate

Part No. Name Quantity

Inverter driven motor pump

Controller

AC fan

Base

Page 8: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

O-20

Specifications

Pressure – Flow rate characteristics (Example)Maximum operating pressure 7 MPa

Maximum discharge rate 60 L/minModel code

SUT00S6007-30SUT06S6007-30

Super Unit [Single pump type]

Flow

rate

(L/m

in)

Pressure (MPa)

10

20

30

40

60

80

90

100

110

50

70

2 4 6 8 10 12 14 161 3 5 7 9 11 13 15

SUTS3007

SUTS4007 SUTS4007

SUTS6007

SUTS8007

SUTS1507

SUTS1107

SUTS3007

SUTS4007

SUTS6007

SUTS8007

SUTS1507

SUTS11007

* Operating flow rate at the maximum pressure in continuous operation:14 L/min maximum

* The graph shows actual flow rates (representative values).

SUT00S6007-30 SUT06S6007-30

30

22.1

21.7

20.2

56

1.5 to 7.0

7.0

8.7 to 61.1

Equivalent to 5.0 kW

3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)

0 to 60°C (Recommended operating temperature range: 15 to 50°C)

− 60

0 to 40°C

−20 to 60°C

85% RH maximum (No condensation)

Indoors (Be sure to secure the unit with bolts.)

Ivory white (Munsell code 5Y7.5/1)

Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel

Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil• Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 10 • Volumetric water content: 0.1% maximum

• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.• Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.

To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.• Be sure to connect the ground terminal.

1 channel (1 common contact), dry contact, Contact capacity: DC 30 V, 0.5 A (Resistance load)

Tankless type Unit type

61.1

5 channels

97

Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.*3: The unit incorporates a safety valve.*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics” and the description of how to select a unit in the separate catalog for Super Units. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.

Model

External input signal

Motor pump/unitPower supply

AC3 φ 200 V (50 Hz)Rated current

(A)

Usable oil *2

Others

Operating conditions

Operating hydraulic oil temperature

Operating ambient temperature

Storage ambient temperature

Operating ambient humidity

Installation site

AC3 φ 200 V (60 Hz)

AC3 φ 220 V (60 Hz)

Power source breaker setting (A)

Mass (kg)

Standard coating color

Pump unit

Maximum discharge rate (Theoretical value; L/min) *1

Motor capacity (Equivalent kW)Motor capacity

Maximum operating pressure (MPa)

Operating flow rate adjustment range (L/min)

Operating pressure adjustment range (MPa)

Tank capacity (L)

Contact outputExternal

output signalDigital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel

Tankless type

Unit type

Page 9: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

OIL

CO

OLI

NG

EQ

UIP

ME

NT

O

O-21

SUT00S6007-30

SUT06S60L07-20-F

Part No. Name Quantity

6-1 Inverter driven motor pump 16-2 Controller 1

2 Suction strainer 13 Stop valve 14 Oil level gauge 15 Oil filler port with air breather 1

7 Oil cooler

1 Oil tank 1

8 AC fan 19 Return filter 1

110 Check valve

1

Part No. Name Quantity

1-1 Inverter driven motor pump 1

1-2 Controller 1

2 AC fan 1

3 Base 1

4 Check valve 1

BoltCaution plate

(Fitted with a vinyl cap at shipment)

Rc¾P

1-2

2

1-1

3

4

(294

)15

354

1538

4

Pressure indication and operation panel

Unloading port Rc½(Fitted with a vinyl cap at shipment)

(136)

1557815608

(95) (1

80)

(73)

(140)

(Fitted with a vinyl cap at shipment)

Rc⅜

(Fitted with a vinyl cap at shipment)

DR

(86)(143)

608

(95)

(226

)(2

82)

(466

)

3054830

Suction port: Rc1

45(4

21)

3032430

384

φ21 hole(Signal cable port)(Power cable port)

φ28 hole

(Fitted with a vinyl cap at shipment)

Rc1T

(plugged at factory)Rc¾T

(Fitted with a vinyl cap at shipment)Rp¾ (above oil level)DR

4-M8

(Fitted with a vinyl cap at shipment)

Rc¾P

Foundation plate (Option)(E-SUTPLATE-2)Pressure indication and operation panel

2-M8 (through hole)Tapped holes for mounting the foundation plate (at 4 locations)

17015018832710085

3711

0

42

100

50

(311

)

(620) (40)

Optional port: Rp⅜

Optional port: Rp½

(40)

20 10530

30 30 25

4020

595

8585(707)

648

70 95(4

41)

450500

70

(50)

Oil sampling port/Oil drain port: Rc½

639

716

Cleaning port

60 LUpper limit (Yellow line)

45 LLower limit (Red line)

155

59 104

6-2

6-12

1

8

7

3

(M8 bolts recommended)4-φ10 holes (for fixing bolts)

(M12 bolts recommended)4-φ15 holes (for fixing bolts)

Suction air

Wing bolt for fastening during transportation (at 1 location on the back)(To be removed before operation)

(241

)

Safety caution nameplate

Unit nameplate

Safety caution nameplate

Unit nameplate

Suction airWing bolt for fastening during

transportation (at 1 location)(To be removed before operation)

(Manifold bracket mount)

External dimension diagram

Tankless type

Unit type

Page 10: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

O-22

Specifications

Pressure – Flow rate characteristics (Example)Maximum operating pressure 7 MPa

Maximum discharge rate 80 L/minModel code

SUTS8007-30

Super Unit [Single pump type]

Flow

rate

(L/m

in)

Pressure (MPa)

10

20

30

40

60

80

90

100

110

50

70

2 4 6 8 10 12 14 161 3 5 7 9 11 13 15

SUTS3007

SUTS4007 SUTS4007

SUTS6007

SUTS8007

SUTS1507

SUTS11007

SUTS3007

SUTS4007

SUTS6007

SUTS8007

SUTS1507

SUTS11007

* Operating flow rate at the maximum pressure in continuous operation:19 L/min maximum

* The graph shows actual flow rates (representative values).

50

25.5

24.8

22.7

72

1.5 to 7.0

7.0

11.6 to 83.0

Equivalent to 7.0 kW

3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)

0 to 60°C (Recommended operating temperature range: 15 to 50°C)

− 100

0 to 40°C

−20 to 60°C

85% RH max. (No condensation)

Indoors (Be sure to secure the unit with bolts.)

Ivory white (Munsell code 5Y7.5/1)

Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel

Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil• Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 10 • Volumetric water content: 0.1% maximum

• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.• Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.

To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.• Be sure to connect the ground terminal.

1 channel (1 common contact), dry contact, Contact capacity: DC 30 V, 0.5 A (Resistance load)

Tankless type Unit type

83.0

5 channels

Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.*3: The unit incorporates a safety valve.*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics” and the description of how to select a unit in the separate catalog for Super Units. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.

131

50

Model

External input signal

Motor pump/unitPower supply

AC3 φ 200 V (50 Hz)Rated current

(A)

Usable oil *2

Others

Operating conditions

Operating hydraulic oil temperature

Operating ambient temperature

Storage ambient temperature

Operating ambient humidity

Installation site

AC3 φ 200 V (60 Hz)

AC3 φ 220 V (60 Hz)

Power source breaker setting (A)

Mass (kg)

Standard coating color

Pump unit

Maximum discharge rate (Theoretical value; L/min) *1

Motor capacity (Equivalent kW)Motor capacity

Maximum operating pressure (MPa)

Operating flow rate adjustment range (L/min)

Operating pressure adjustment range (MPa)

Tank capacity (L)

Contact outputExternal

output signalDigital output

SUT00S8007-30 SUT10S8007-30

2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel

Tankless type

Unit type

Page 11: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

OIL

CO

OLI

NG

EQ

UIP

ME

NT

O

O-23

SUT00S8007-30

Part No. Name Quantity

1-1 Inverter driven motor pump 1

1-2 Controller 1

2 AC fan 1

3 Base 1

4 Check valve 1

Transportation nameplate

(441

)45

3032430

(260

)

(486

)

(To be removed before operation)

Wing bolt for fastening during transportation (at 2 locations)

(Plugged (with O-ring) at shipment)

Suction port: Rc1(142)3057030 3

(244

)

(90)

(300

) (408

)

1-1

(85.5)

1-2

15 1515(135)

600630(60)

Motor cable

1535

438

4 294

(Fitted with a vinyl cap at shipment)

Unloading port: Rc½

(196

)(1

25)

(139)

4

SUT10S8007‐30

(Fitted with a vinyl cap at shipment)

Rc¾P

Pressure indication and operation panel

(Fitted with a vinyl cap at shipment)Rc⅜DR

Part No. Name Quantity

6-1 Inverter driven motor pump 16-2 Controller 1

2 Suction strainer 13 Stop valve 14 Oil level gauge 15 Oil filler port with air breather 1

7 Oil cooler

1 Oil tank 1

8 AC fan 19 Return filter 1

110 Check valve

1

(M8 bolts recommended)4-φ10 holes (for fixing bolts)

BoltCaution plate

Cleaning port tightening caution nameplate

Safety caution nameplate

Unit nameplateSUT10D80L07-30

(plugged at factory)Rc1-¼

(Fitted with a vinyl cap at shipment)Rp¾ (above oil level)DR

(Manifold bracket mount)4-M8

Pressure indication and operation panel

(Fitted with a vinyl cap at shipment)

Rc1-½T

T

(Fitted with a vinyl cap at shipment)

Rc¾P

Foundation plate (Option)(E-SUTPLATE-2)

2-M8 (through hole)Tapped holes for mounting the foundation plate (at 4 locations)

Wing bolt for fastening during transportation (at 1 location on the back)

(To be removed before operation)

100 LUpper limit (Yellow line)76 LLower limit (Red line)

3

59

10

46-2

6-1

2

1

8

7

170150

(188)(327)100(85)

(620)

100

50

(439

)

(40) (40)

150

172

17

Optional port: Rp⅜Optional port: Rp½

70

10

700530

30 30

25

4020

59567

1

208585

95(4

41)

(188)(895)

(216

)

580630

70 155(50)

Oil sampling port/Oil drain port: Rc½

450 50 80

(647

)

Cleaning port

(M12 bolts recommended)4-φ15 holes (for fixing bolts)

2

Suction air

Suction air

754

Safety caution nameplate

Unit nameplate

External dimension diagram

Tankless type

Unit type

Page 12: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

O-24

Specifications

Pressure – Flow rate characteristics (Example)Maximum operating pressure 7 MPa

Maximum discharge rate 110 L/minModel code

SUT00S11007-30

Super Unit [Single pump type]

Flow

rate

(L/m

in)

Pressure (MPa)

10

20

30

40

60

80

90

100

110

50

70

2 4 6 8 10 12 14 161 3 5 7 9 11 13 15

SUTS3007

SUTS4007

SUTS6007

SUTS8007

SUTS1507

SUTS11007

SUTS3007

SUTS4007

SUTS6007

SUTS8007

SUTS1507

SUTS11007

* Operating flow rate at the maximum pressure in continuous operation:16 L/min maximum

* The graph shows actual flow rates (representative values).

SUT00S11007-30

38.3

37.8

34.9

112

1.5 to 7.0

7.0

13.3 to 110

Equivalent to 11.0 kW

3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)

0 to 60°C (Recommended operating temperature range: 15 to 50°C)

0 to 40°C

−20 to 60°C

85% RH max. (No condensation)

Indoors (Be sure to secure the unit with bolts.)

Ivory white (Munsell code 5Y7.5/1)

Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel

Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil• Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 10 • Volumetric water content: 0.1% maximum

• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.• Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.

To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.• Be sure to connect the ground terminal.

1 channel (1 common contact), dry contact, Contact capacity: DC 30 V, 0.5 A (Resistance load)

Tankless type

110

5 channels

75

Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.*3: The unit incorporates a safety valve.*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics” and the description of how to select a unit in the separate catalog for Super Units. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.

2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel

Model

External input signal

Motor pumpPower supply

AC3 φ 200 V (50 Hz)Rated current

(A)

Usable oil *2

Others

Operating conditions

Operating hydraulic oil temperature

Operating ambient temperature

Storage ambient temperature

Operating ambient humidity

Installation site

AC3 φ 200 V (60 Hz)

AC3 φ 220 V (60 Hz)

Power source breaker setting (A)

Mass (kg)

Standard coating color

Pump unit

Maximum discharge rate (Theoretical value; L/min) *1

Motor capacity (Equivalent kW)Motor capacity

Maximum operating pressure (MPa)

Operating flow rate adjustment range (L/min)

Operating pressure adjustment range (MPa)

Tank capacity (L)

Contact outputExternal

output signalDigital output

Tankless type

Page 13: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

OIL

CO

OLI

NG

EQ

UIP

ME

NT

O

O-25

SUT00S11007-30SUT00D11021-30Controller (Installed separately)

SUT00S11007-30

DAIKIN INDUSTRIES,LTD. MADE IN JAPAN

SUT00S※※※※※-※※-A-※INSULATION CLASS  :  F

V3φ 2003φ 2003φ 220

Hz0.9450

6060

MASSMAX. FLOWMAX.PRESSURE: 17.6 MPa

: 80 L/min: 88 kg

DAIKIN INDUSTRIES,LTD. MADE IN JAPAN

注1.MFG No.:

0.940.9461

6262A PF

204117

261

15

241

108 108

228

170

323

168 496

42 118

243

207

112

76.5 95.5 132.5

275228

151

819

19

**

IC

N

CE

D

129

9587

INSULATION CLASS  :  FV

3φ 2003φ 2003φ 220

Hz506060

MASSMAX. FLOWMAX.PRESSURE: MPa

: L/min: kg

DAIKIN INDUSTRIES,LTD. MADE IN JAPAN

MFG No.:

A PF

WARNING

May cause

Wait 5 minutes until

・Disconnect all power

DC Bus capacitors

electric shock.

感電のおそれがあります。 ターミナルカバーを開けないで下さい。・通電中及び電源遮断後5分以内は

DAIKIN INDUSTRIES,LTD.

before opening terminal

dischange.

危 険

cover of unit.

FG

GNDFG

Z-+5V

Z+B-

A-

THM-

B+

A+

THM+AGND

AGNDAO2

AO1

AGND

AGND

AGNDP_S

A5V

ALM_B

DOCOM

ALM_C

ALM_A

DO7DO6

DO4DO5

DO3

DO2

DI8

DI6

DO1

DI7

DI5DI4

DI2

DICOM

DI3

DI1

DGNDRxD

FGTxD

FG

(QO)

(PO)

AIN2

AIN1(QI)

(PI)

Cooling fanCooling fan

1732

7.5

34

95.5

233

39

(5)207212

636

111

.5

378.

5

25 180 (25)

230

240

(5)(5)

180

Motor wiring port (φ28)

AC fan, thermistor wiring port (φ21)

Suction port: Rc1-¼

Encoder wiring connector

Drain portRc⅜

Suction air

Discharge portUnloading portRc¾

4-14.5 (Installation)

Rc1-¼

<Top>Cooling fan suction

Cooling fan exhaust

- Encoder- Motor thermistor- Pressure sensor- I/O signal

User I/O terminal (M3)

Controller nameplate

M5 screw (for ground connection)

Controller installation hole4-φ8 (M6 bolts recommended)

Operation panel

Product nameplate

- Main power supply- DC reactor- Regenerative resistor- Motor output

Main power supply terminal block (M5)

M5 screw (for ground connection)

M4 screw (for ground connection)

- Electromagnetic valve power supply- AC fan power supply

Electromagnetic valve terminal block (M4)

External dimension diagram

Tankless type

Unit type

Page 14: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

O-26

Specifications

Pressure – Flow rate characteristics (Example)Maximum operating pressure 10 MPa

Maximum discharge rate 15 L/minModel code

SUTS1510-30

Super Unit [Single pump type]

Flow

rate

(L/m

in)

Pressure (MPa)

10

20

30

40

60

80

90

50

70

2 4 6 8 10 12 14 161 3 5 7 9 11 13 15

SUTS3010

SUTS1510

SUTS3010

SUTS1510

* Operating flow rate at the maximum pressure in continuous operation:3 L/min maximum

* The graph shows actual flow rates (representative values).

SUT00S1510-30 SUT03S1510-30

15

8.0

7.8

7.5

39

1.5 to 10.0

10.0

2.5 to 15.2

Equivalent to 2.8 kW

3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)

− 30

0 to 40°C

−20 to 60°C

85% RH max. (No condensation)

Indoors (Be sure to secure the unit with bolts.)

Ivory white (Munsell code 5Y7.5/1)

Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel

Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil• Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum

• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.• Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.

To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.• Be sure to connect the ground terminal.

1 channel (1 common contact), dry contact, Contact capacity: DC 30 V, 0.5 A (Resistance load)

Tankless type Unit type

15.2

5 channels

Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.*3: The unit incorporates a safety valve.*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics” and the description of how to select a unit in the separate catalog for Super Units. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.

59

0 to 60°C (Recommended operating temperature range: 15 to 50°C)

Model

External input signal

Motor pump/unitPower supply

AC3 φ 200 V (50 Hz)Rated current

(A)

Usable oil *2

Others

Operating conditions

Operating hydraulic oil temperature

Operating ambient temperature

Storage ambient temperature

Operating ambient humidity

Installation site

AC3 φ 200 V (60 Hz)

AC3 φ 220 V (60 Hz)

Power source breaker setting (A)

Mass (kg)

Standard coating color

Pump unit

Maximum discharge rate (Theoretical value; L/min) *1

Motor capacity (Equivalent kW)Motor capacity

Maximum operating pressure (MPa)

Operating flow rate adjustment range (L/min)

Operating pressure adjustment range (MPa)

Tank capacity (L)

Contact outputExternal

output signalDigital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel

Tankless type Unit type

Page 15: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

OIL

CO

OLI

NG

EQ

UIP

ME

NT

O

O-27

SUT00S1510-30

SUT03S1510-30

Part No. Name Quantity

1-1 Inverter driven motor pump 1

1-2 Controller 1

2 AC fan 1

3 Base 1

Part No. Name Quantity

6-1 Inverter driven motor pump 1

6-2 Controller 1

2 Suction strainer 1

3 Stop valve 1

4 Oil level gauge 1

5 Oil filler port with air breather 1

7 Oil cooler

1 Oil tank 1

1

8 AC fan 1

BoltCaution nameplate

Cleaning port tightening caution nameplate

Unit nameplateSUT03S15L10-30

450500

70 155

(50)

309

(550)(580)

70

20 10 30 30 25

4020

700530 8585

95

419 (5

16)

462

(620)196

140.

5

42

92

100

50

17015077.5177.5

132.5 550

(40)(40)

φ21 hole(Signal cable port)

(Power cable port)φ28 hole

Suction port: G¾

Rc⅜DR

(Fitted with a vinyl cap at shipment)Rc⅜P

1-2

2

1-1

3

(87)1549015

520

(162

)(254

)

1531

415

344

Pressure indication and operation panel

(109

)

(246

)

(260

)

(83)

45(2

20)

(466

)

30 460 30

520

30 284 30

344

45(4

21)

(Fitted with a vinyl cap at shipment)Rp¾ (above oil level)DR

(Fitted with a vinyl cap at shipment)

Rc1T

Optional port: Rp⅜

(Manifold bracket mount)4-M8

Optional port: Rp½

(Fitted with a vinyl cap at shipment)Rc⅜P

Pressure indication and operation panel

Foundation plate (Option)(E-SUTPLATE-2)

3

φ21 hole(Signal cable port)

(Power cable port)φ28 hole

8

7

30 LUpper limit (Yellow line)23 LLower limit (Red line)

2-M8 (through hole)Tapped holes for mounting the foundation plate (at 4 locations)

6-1

5 46-2Cleaning port

Oil sampling port/Oil drain port: Rc½

1

(M8 bolts recommended)4-φ10 holes (for fixing bolts)

(M12 bolts recommended)4-φ15 holes (for fixing bolts)

2

Suction air

Suction air

Wing bolt for fastening during transportation (at 1 location on the back)(To be removed before operation)

Safety caution nameplate

Unit nameplate

Safety caution nameplate

(Fitted with a vinyl cap at shipment)

(Fitted with a vinyl cap at shipment)

Wing bolt for fastening during transportation (at 1 location)

(To be removed before operation)

External dimension diagram

Tankless type

Unit type

Page 16: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

O-28

Specifications

Pressure – Flow rate characteristics (Example)Maximum operating pressure 10 MPa

Maximum discharge rate 30 L/minModel code

SUTS3010-30

Super Unit [Single pump type]

Flow

rate

(L/m

in)

Pressure (MPa)

10

20

30

40

60

80

90

50

70

2 4 6 8 10 12 14 161 3 5 7 9 11 13 15

SUTS3010

SUTS1510

SUTS3010

SUTS1510

* Operating flow rate at the maximum pressure in continuous operation:5 L/min maximum

* The graph shows actual flow rates (representative values).

SUT00S3010-30 SUT03S3010-30

20

18.4

18.4

16.9

46

1.5 to 10.0

10.0

3.4 to 25.6

Equivalent to 3.7 kW

3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)

0 to 60°C (Recommended operating temperature range: 15 to 50°C)

− 30

0 to 40°C

−20 to 60°C

85% RH max. (No condensation)

Indoors (Be sure to secure the unit with bolts.)

Ivory white (Munsell code 5Y7.5/1)

Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel

Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil• Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 10 • Volumetric water content: 0.1% maximum

• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.• Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.

To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.• Be sure to connect the ground terminal.

1 channel (1 common contact), dry contact, Contact capacity: DC 30 V, 0.5 A (Resistance load)

Tankless type Unit type

25.6

5 channels

64

Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.*3: The unit incorporates a safety valve.*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics” and the description of how to select a unit in the separate catalog for Super Units. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.

Model

External input signal

Motor pump/unitPower supply

AC3 φ 200 V (50 Hz)Rated current

(A)

Usable oil *2

Others

Operating conditions

Operating hydraulic oil temperature

Operating ambient temperature

Storage ambient temperature

Operating ambient humidity

Installation site

AC3 φ 200 V (60 Hz)

AC3 φ 220 V (60 Hz)

Power source breaker setting (A)

Mass (kg)

Standard coating color

Pump unit

Maximum discharge rate (Theoretical value; L/min) *1

Motor capacity (Equivalent kW)Motor capacity

Maximum operating pressure (MPa)

Operating flow rate adjustment range (L/min)

Operating pressure adjustment range (MPa)

Tank capacity (L)

Contact outputExternal

output signalDigital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel

Tankless type Unit type

Page 17: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

OIL

CO

OLI

NG

EQ

UIP

ME

NT

O

O-29

SUT03S30L10-30

SUT00S3010-30

Part No. Name Quantity

1 Oil tank 1

2 Suction strainer 1

3 Stop valve 1

4 Oil level gauge 1

5 Oil filler port with air breather 1

6-1 Inverter driven motor pump 1

6-2 Controller

7 Oil cooler 1

8 AC fan 1

1

Part No. Name Quantity

1-1 Inverter driven motor pump 1

1-2 Controller 1

2 AC fan 1

3 Base 1

BoltCaution nameplate

SUT03S30L10-30Cleaning port tightening caution nameplate

φ21 hole(Signal cable port)

(Fitted with a vinyl cap at shipment)Rc⅜P

(Fitted with a vinyl cap at shipment)Rc⅜DR

Pressure indication and operation panel

(202

)

(87)

1549015

520

520

(294

)

1535

415

384

3046030

(108

)

(245

)

(259

)

(83)

(466

)

220

45(4

21)

30 324 30

384

1-2

1-1

2

3

φ21 hole(Signal cable port)

(Power cable port)φ28 hole

(Fitted with a vinyl cap at shipment)

Rc1T

Optional port: Rp⅜

(Fitted with a vinyl cap at shipment)Rp¾ (above oil level)DR

Optional port: Rp½

(Fitted with a vinyl cap at shipment)Rc⅜P

Foundation plate (Option)(E-SUTPLATE-2)Pressure indication and

operation panel

3

(Manifold bracket mount)4-M8

2-M8 (through hole)Tapped holes for mounting the foundation plate (at 4 locations)

6-1

5 4

6-2

2595

419

(516

)

20 10 30 30

700530 8585

704020

(620)196

140

42

92

100

50

170150

132.5 550

77.5177.5

(40) (40)

Cleaning port

Oil sampling port/Oil drain port: Rc½

450500

(550)

(580)

462

70 155

(50)

(309

)

2

1

(Fitted with a vinyl cap at shipment)

Suction port: G¾

(Power cable port)φ28 hole

(M8 bolts recommended)4-φ10 holes (for fixing bolts)

(M12 bolts recommended)4-φ15 holes (for fixing bolts)

8

7

Suction air

Wing bolt for fastening during transportation (at 1 location on the back)(To be removed before operation)

Unit nameplate

Wing bolt for fastening during transportation (at 1 location)(To be removed before operation)

Unit nameplate

Safety caution nameplate

30 LUpper limit (Yellow line)23 LLower limit (Red line)

Suction air

Safety caution nameplate

External dimension diagram

Tankless type

Unit type

Page 18: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

O-30

Specifications

Pressure – Flow rate characteristics (Example)Maximum operating pressure 16 MPa

Maximum discharge rate 15/30 L/minModel code

SUTS1516-30SUTS3016-30

Super Unit [Single pump type]

Flow

rate

(L/m

in)

Pressure (MPa)

10

20

30

40

60

80

90

50

70

2 4 6 8 10 12 14 161 3 5 7 9 11 13 15

SUTS3016

SUTS1516

SUTS3016

SUTS1516

* Operating flow rate at the maximum pressure in continuous operation:5 L/min maximum

* The graph shows actual flow rates (representative values).

SUT00S1516-30 SUT00S3016-30 SUT03S1516-30 SUT06S3016-30

20 30 20 30

46 52 64 83

1.5 to 16.0

16.0

2.4 to 15.2 3.4 to 25.6 2.4 to 15.2 3.4 to 25.6

Equivalent to 3.7 kW Equivalent to 5.0 kW Equivalent to 3.7 kW Equivalent to 5.0 kW

3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)

0 to 60°C (Recommended operating temperature range: 15 to 50°C)

− 30 60

0 to 40°C

−20 to 60°C

85% RH max. (No condensation)

Indoors (Be sure to secure the unit with bolts.)

Ivory white (Munsell code 5Y7.5/1)

Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel

Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil• Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum

• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.• Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.

To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.• Be sure to connect the ground terminal.

1 channel (1 common contact), dry contact, Contact capacity: DC 30 V, 0.5 A (Resistance load)

2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel

Tankless type Unit type

15.2 25.6 15.2 25.6

5 channels

Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.*3: The unit incorporates a safety valve.*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics” and the description of how to select a unit in the separate catalog for Super Units. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.

Model

External input signal

Motor pump/unitPower supply

AC3 φ 200 V (50 Hz)Rated current

(A)

Usable oil *2

Others

Operating conditions

Operating hydraulic oil temperature

Operating ambient temperature

Storage ambient temperature

Operating ambient humidity

Installation site

AC3 φ 200 V (60 Hz)

AC3 φ 220 V (60 Hz)

Power source breaker setting (A)

Mass (kg)

Standard coating color

Pump unit

Maximum discharge rate (Theoretical value; L/min) *1

Motor capacity (Equivalent kW)Motor capacity

Maximum operating pressure (MPa)

Operating flow rate adjustment range (L/min)

Operating pressure adjustment range (MPa)

Tank capacity (L)

Contact outputExternal

output signalDigital output

15.2

15.2

14.6

21.4

21.4

20.2

15.2

15.2

14.6

21.4

21.4

20.2

Tankless type Unit type

Page 19: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

OIL

CO

OLI

NG

EQ

UIP

ME

NT

O

O-31

SUT00S1516-30SUT00S3016-30

SUT06S3016-30

SUT03S1516-30

Part No. Name Quantity

1-1 Inverter driven motor pump 1

1-2 Controller 1

2 AC fan 1

3 Base 1

Part No. Name Quantity

Part No. Name Quantity

6-1 Inverter driven motor pump 1

6-2 Controller 1

2 Suction strainer 1

3 Stop valve 1

4 Oil level gauge 1

5 Oil filler port with air breather 1

7 Oil cooler 1

1 Oil tank 1

8 AC fan 1

6-1 Inverter driven motor pump 1

6-2 Controller 1

2 Suction strainer 1

3 Stop valve 1

4 Oil level gauge 1

5 Oil filler port with air breather 1

7 Oil cooler 1

1 Oil tank 1

8 AC fan 1

9 Return filter 1

BoltCaution nameplate

SUT03S15L16-30Cleaning port tightening caution nameplate

Cleaning port tightening caution nameplate

BoltCaution nameplate

(Fitted with a vinyl cap at shipment)Rc⅜P

(Fitted with a vinyl cap at shipment)Rc⅜DR

Suction port: G¾

φ21 hole(Signal cable port)(Power cable port)

φ28 hole

φ21 hole(Signal cable port)

(Power cable port)φ28 hole

1-2

1-12

3

(137) (∗77)15578 (∗490)15

608 (∗520)

(202

)(294

)

1535

415

384

30548 (∗460)30

(260

)(2

45)

(109

)45

(133) (∗73)

3032430384

(45)

(421

)

608 (∗520)

(466

)

220

(∗ ): Dimensions for SUT00S1516-30

Optional port: Rp⅜

(Fitted with a vinyl cap at shipment)

Rc1T

(Fitted with a vinyl cap at shipment)Rc1T

(plugged at factory)Rc¾T

(Fitted with a vinyl cap at shipment)

Rp¾ (above oil level)DR

(Fitted with a vinyl cap at shipment)Rp¾ (above oil level)DR

Pressure indication and operation panel

Pressure indication and operation panel

Foundation plate (Option)(E-SUTPLATE-2)

Foundation plate (Option)(E-SUTPLATE-2)

(Fitted with a vinyl cap at shipment)Rc⅜P

(Fitted with a vinyl cap at shipment)Rc⅜P

(Manifold bracket mount)4-M8

(Manifold bracket mount)4-M8

3

23 LLower limit (Red line)

2-M8 (through hole)Tapped holes for mounting the foundation plate (at 4 locations)

2-M8 (through hole)Tapped holes for mounting the foundation plate (at 4 locations)

Oil sampling port/Oil drain port: Rc½

Oil sampling port/Oil drain port: Rc½

1

26-1

5 46-2

Optional port: Rp⅜

Optional port: Rp½

59 6-2

6-1

8

7

3

Cleaning port

4

2

1

70

20 10530

30 30 25

4020

59564

8

450500

70 155

(50)

8585

9530

9

639

700

(620)(40) (40)

100

50

170150186

(360

)

85 100

3711

042

70

20 10 30 30 25

4020

700530 8585

95

419 (5

16)

(620)186

140

4292

100

50

17015077.5

177.5132.5 550

(40) (40)

450500

70 155(50)

(309

) 462

Cleaning port

(Fitted with a vinyl cap at shipment)

(M8 bolts recommended)

4-φ10 holes (for fixing bolts)

(M12 bolts recommended)4-φ15 holes (for fixing bolts)

(M12 bolts recommended)4-φ15 holes (for fixing bolts)

8

7

Suction air

Suction air

Suction air

(To be removed before operation)

716

Wing bolt for fastening during transportation (at 1 location on the back)(To be removed before operation)

Wing bolt for fastening during transportation (at 1 location on the back)(To be removed before operation)

Optional port: Rp½

Safety caution nameplate

Unit nameplate

Safety caution nameplate

Unit nameplate

Safety caution nameplate

Unit nameplate

Pressure indication and operation panel

Wing bolt for fastening during transportation (at 1 location)

30 LUpper limit (Yellow line)

60 LUpper limit (Yellow line)45 LLower limit (Red line)

External dimension diagram

Tankless type

Unit type

Page 20: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

O-32

Specifications

Pressure – Flow rate characteristics (Example)Maximum operating pressure 16 MPa

Maximum discharge rate 40 L/minModel code

Super Unit [Double pump type]

Pressure (MPa)

Flow

rate

(L/m

in)

0 5 10 15 200

10

20

30

40

50

60

70

80

90

100

110

* Operating flow rate at the maximum pressure in continuous operation:8 L/min maximum

* The graph shows actual flow rates (representative values).

SUT00D4016-30 SUT06D4016-30

17.7

16.5

53

1.5 to 15.7

15.7

5.4 to 41.0

Equivalent to 3.7 kW

3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)

0 to 60°C (Recommended operating temperature range: 15 to 50°C)

− 60

0 to 40°C

−20 to 60°C

85% RH max. (No condensation)

Indoors (Be sure to secure the unit with bolts.)

Ivory white (Munsell code 5Y7.5/1)

Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel

Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil• Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum

• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.• Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.

To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.• Be sure to connect the ground terminal.

1 channel (1 common contact), dry contact, Contact capacity: DC 30 V, 0.5 A (Resistance load)

Tankless type Unit type

41.0

5 channels

Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.*3: The unit incorporates a safety valve.*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics” and the description of how to select a unit in the separate catalog for Super Units. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.

94

20

17.9

Model

External input signal

Motor pump/unitPower supply

AC3 φ 200 V (50 Hz)Rated current

(A)

Usable oil *2

Others

Operating conditions

Operating hydraulic oil temperature

Operating ambient temperature

Storage ambient temperature

Operating ambient humidity

Installation site

AC3 φ 200 V (60 Hz)

AC3 φ 220 V (60 Hz)

Power source breaker setting (A)

Mass (kg)

Standard coating color

Pump unit

Maximum discharge rate (Theoretical value; L/min) *1

Motor capacity (Equivalent kW)Motor capacity

Maximum operating pressure (MPa)

Operating flow rate adjustment range (L/min)

Operating pressure adjustment range (MPa)

Tank capacity (L)

Contact outputExternal

output signalDigital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel

SUTD4016-30

Tankless type Unit type

Page 21: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

OIL

CO

OLI

NG

EQ

UIP

ME

NT

O

O-33

SUT00D4016-30

SUT06D4016-30

Part No. Name Quantity

1-1 Inverter driven motor pump 1

1-2 Controller 1

2 AC fan 1

3 Base 1

4 Check valve 1

Part No. Name Quantity

6-1 Inverter driven motor pump 16-2 Controller 1

2 Suction strainer 13 Stop valve 14 Oil level gauge 15 Oil filler port with air breather 1

7 Oil cooler

1 Oil tank 1

8 AC fan 19 Return filter 1

110 Check valve

1

Cleaning port tightening caution nameplate

(620) (40)(40)

70

20 10

700530

30 30 25

4020

59564

8

450500

70 155(50)

639 71

6

3711

0

42

8585

95(4

41)

100

50

170150

(309

)

194.5320.510085

BoltCaution nameplate

Pressure indication and operation panelUnloading port Rc½(Fitted with a vinyl cap at shipment)

(Fitted with a vinyl cap at shipment)

P

(Fitted with a vinyl cap at shipment)

Rc⅜

(Fitted with a vinyl cap at shipment)

DR

Rc¾

1-2

1-1

4

6083054830

Suction port: Rc1

(142)1557815

608

(95)

(180

)(7

3)

(146)

(294

)15

354

1538

4

(93)

(149)

(95)

(226

)(2

82)

45

220

(466

)

2

330 324 30

384

45(4

21)

(Fitted with a vinyl cap at shipment)

Rc1T

(Fitted with a vinyl cap at shipment)Rp¾ (above oil level)DR

Optional port: Rp⅜

Optional port: Rp½

(plugged at factory)Rc¾T

(Manifold bracket mount)4-M8

(Fitted with a vinyl cap at shipment)

Rc¾P

Foundation plate (Option)(E-SUTPLATE-2)Pressure indication and operation panel

3

59 106-2

6-1

Oil sampling port/Oil drain port: Rc½

60 LUpper limit (Yellow line)

45 LLower limit (Red line)

4

2

1

Cleaning port

2-M8 (through hole)Tapped holes for mounting the foundation plate (at 4 locations)

φ21 hole(Signal cable port)(Power cable port)

φ28 hole

(M8 bolts recommended)4-φ10 holes (for fixing bolts)

(M12 bolts recommended)

4-φ15 holes (for fixing bolts)

Suction air

8

7

Suction air

Wing bolt for fastening during transportation (at 1 location)

(To be removed before operation)

Wing bolt for fastening during transportation (at 1 location on the back)(To be removed before operation)

Safety caution nameplate

Unit nameplate

Safety caution nameplate

Unit nameplate

External dimension diagram

Tankless type

Unit type

Page 22: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

O-34

Specifications

Pressure – Flow rate characteristics (Example)Maximum operating pressure 21 MPa

Maximum discharge rate 60 L/minModel code

Super Unit [Double pump type]

Pressure (MPa)

Flow

rate

(L/m

in)

0 5 10 15 200

10

20

30

40

50

60

70

80

90

100

110

* Operating flow rate at the maximum pressure in continuous operation:6.5 L/min maximum

* The graph shows actual flow rates (representative values).

SUT00D6021-30 SUT06D6021-30 SUT10D6021-30

21.7

20.2

58 99 112

1.5 to 20.6

20.6

8.7 to 61.1

Equivalent to 5.0 kW

3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)

0 to 60°C (Recommended operating temperature range: 15 to 50°C)

− 60 100

0 to 40°C

−20 to 60°C

85% RH max. (No condensation)

Indoors (Be sure to secure the unit with bolts.)

Ivory white (Munsell code 5Y7.5/1)

Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel

Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil• Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum

• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.• Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.

To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.• Be sure to connect the ground terminal.

1 channel (1 common contact), dry contact, Contact capacity: DC 30 V, 0.5 A (Resistance load)

2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel

Tankless type Unit type

61.1

5 channels

Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.*3: The unit incorporates a safety valve.*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics” and the description of how to select a unit in the separate catalog for Super Units. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.

30

22.1

Model

External input signal

Motor pump/unitPower supply

AC3 φ 200 V (50 Hz)Rated current

(A)

Usable oil *2

Others

Operating conditions

Operating hydraulic oil temperature

Operating ambient temperature

Storage ambient temperature

Operating ambient humidity

Installation site

AC3 φ 200 V (60 Hz)

AC3 φ 220 V (60 Hz)

Power source breaker setting (A)

Mass (kg)

Standard coating color

Pump unit

Maximum discharge rate (Theoretical value; L/min) *1

Motor capacity (Equivalent kW)Motor capacity

Maximum operating pressure (MPa)

Operating flow rate adjustment range (L/min)

Operating pressure adjustment range (MPa)

Tank capacity (L)

Contact outputExternal

output signalDigital output

SUTD6021-30

Tankless type Unit type

Page 23: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

OIL

CO

OLI

NG

EQ

UIP

ME

NT

O

O-35

SUT00D6021-30

SUT06D6021-30

SUT10D6021-30

Part No. Name Quantity

6-1 Inverter driven motor pump 1

6-2 Controller 1

2 Suction strainer 1

3 Stop valve 1

4 Oil level gauge 1

5 Oil filler port with air breather 1

7 Oil cooler 1

1 Oil tank 1

8 AC fan 1

9 Return filter 1

10 Check valve 1

Part No. Name Quantity

6-1 Inverter driven motor pump 1

6-2 Controller 1

2 Suction strainer 1

3 Stop valve 1

4 Oil level gauge 1

5 Oil filler port with air breather 1

7 Oil cooler 1

1 Oil tank 1

8 AC fan 1

9 Return filter 1

10 Check valve 1

Part No. Name Quantity

1-1 Inverter driven motor pump 1

1-2 Controller 1

2 AC fan 1

3 Base 1

4 Check valve 1

Cleaning port tightening caution nameplate

BoltCaution nameplate

Cleaning port tightening caution nameplate

BoltCaution nameplate

(136) 1557815608

Pressure indication and operation panel

(294

)

1535

415

384

(Fitted with a vinyl cap at shipment)Rc¾P

(Fitted with a vinyl cap at shipment)Unloading port Rc½

(Fitted with a vinyl cap at shipment)Rc⅜DR

1-2

1-1

2

3

608

3032430384

(45)

(421

)

45

(466

)

(86)

(142.5)

(95)

(226

)(2

82)

(95)

(73)

(180

)

(140)

Optional port: Rp⅜

Optional port: Rp½

(Fitted with a vinyl cap at shipment)Rc1T (Fitted with a vinyl cap at shipment)

Rp¾ (above oil level)DR

Foundation plate (Option)(E-SUTPLATE-2)

(Fitted with a vinyl cap at shipment)Rc¾P

(Manifold bracket mount)4-M8

(620)(40) (40)

2-M8 (through hole)Tapped holes for mounting the foundation plate (at 4 locations)

Oil sampling port/Oil drain port: Rc½

Cleaning port

4

4

2

1

450500

70 155

(50)

639

716

716

59 6-2

6-1

8

7

8

7

10

3

(309

)

3711

042

100

50

17015018832710085

70

20 10530

30 30 25

4020

59564

8

8585

95(4

41)

700

Optional port: Rp⅜

Optional port: Rp½

(Fitted with a vinyl cap at shipment)

Rc1T

(plugged at factory)Rc¾T

(plugged at factory)Rc¾T

(Fitted with a vinyl cap at shipment)Rp¾ (above oil level)DR 170150

18832710085

(Manifold bracket mount)4-M8

100

50

(439

)

Foundation plate (Option)(E-SUTPLATE-2)

(Fitted with a vinyl cap at shipment)Rc¾P

(620)(40) (40)

3

2-M8 (through hole)Tapped holes for mounting the foundation plate (at 4 locations)

59 6-2

6-1

10

70

20 10530

30 30

4020

59564

8

8585

95(4

41)

700

25 450

70 155

Cleaning port

2

1

639

(50)

Oil sampling port/Oil drain port: Rc½

4

50 80580630

167

110

172

φ21 hole(Signal cable port)(Power cable port)

φ28 hole (M8 bolts recommended)4-φ10 holes (for fixing bolts)

(M12 bolts recommended)4-φ15 holes (for fixing bolts)

(M12 bolts recommended)4-φ15 holes (for fixing bolts)

Suction air

Suction air

Suction air

Wing bolt for fastening during transportation (at 1 location)

(To be removed before operation)

Wing bolt for fastening during transportation (at 1 location on the back)(To be removed before operation)

Wing bolt for fastening during transportation (at 1 location on the back)(To be removed before operation)

(Fitted with a vinyl cap at shipment)

Suction port: Rc1

Safety caution nameplate

Safety caution nameplate

Unit nameplate

(241

)

Unit nameplate

Unit nameplate60 LUpper limit (Yellow line)45 LLower limit (Red line)

100 LUpper limit (Yellow line)76 LLower limit (Red line)

Safety caution nameplate

External dimension diagram

Tankless type

Unit type

Page 24: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

O-36

Specifications

Pressure – Flow rate characteristics (Example)Maximum operating pressure 21 MPa

Maximum discharge rate 80 L/minModel code

Super Unit [Double pump type]

Pressure (MPa)

Flow

rate

(L/m

in)

0 5 10 15 200

10

20

30

40

50

60

70

80

90

100

110

* Operating flow rate at the maximum pressure in continuous operation:14 L/min maximum

* The graph shows actual flow rates (representative values).

SUT00D8021-30 SUT10D8021-30 SUT16D8021-30

50

25.5

24.8

22.7

72 133 145

1.5 to 20.6

20.6

11.6 to 83.0

Equivalent to 7.0 kW

3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)

0 to 60°C (Recommended operating temperature range: 15 to 50°C)

− 100 160

0 to 40°C

−20 to 60°C

85% RH max. (No condensation)

Indoors (Be sure to secure the unit with bolts.)

Ivory white (Munsell code 5Y7.5/1)

Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel

Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil• Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum

• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.• Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.

To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.• Be sure to connect the ground terminal.

1 channel (1 common contact), dry contact, Contact capacity: DC 30 V, 0.5 A (Resistance load)

Tankless type Unit type

83.0

5 channels

Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.*3: The unit incorporates a safety valve.*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics” and the description of how to select a unit in the separate catalog for Super Units. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.

Model

External input signal

Motor pump/unitPower supply

AC3 φ 200 V (50 Hz)Rated current

(A)

Usable oil *2

Others

Operating conditions

Operating hydraulic oil temperature

Operating ambient temperature

Storage ambient temperature

Operating ambient humidity

Installation site

AC3 φ 200 V (60 Hz)

AC3 φ 220 V (60 Hz)

Power source breaker setting (A)

Mass (kg)

Standard coating color

Pump unit

Maximum discharge rate (Theoretical value; L/min) *1

Motor capacity (Equivalent kW)Motor capacity

Maximum operating pressure (MPa)

Operating flow rate adjustment range (L/min)

Operating pressure adjustment range (MPa)

Tank capacity (L)

Contact outputExternal

output signalDigital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel

SUTD8021-30

Tankless type Unit type

Page 25: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

OIL

CO

OLI

NG

EQ

UIP

ME

NT

O

O-37

SUT00D8021-30

Part No. Name Quantity

1-1 Inverter driven motor pump 1

1-2 Controller 1

2 AC fan 1

3 Base 1

4 Check valve 1

SUT10D8021-30SUT16D8021-30

Part No. Name Quantity

6-1 Inverter driven motor pump 16-2 Controller 1

2 Suction strainer 13 Stop valve 14 Oil level gauge 15 Oil filler port with air breather 1

7 Oil cooler

1 Oil tank 1

8 AC fan 19 Return filter 1

110 Check valve

1

Transportation nameplate

Motor cable

294

15

384

354

15

(60) 630600

(97)

15 15

(Fitted with a vinyl cap at shipment)Unloading port: Rc½

(139)

(125

) (196

)

483

258

3

2

4

(To be removed before operation)

Wing bolt for fastening during transportation (at 2 locations)

(142)

30 30570

(299

)

(90)

(408

)

(311

)

(72)

45(4

41)

30 324 30

(M8 bolts recommended)4-φ10 holes (for fixing bolts)

(M12 bolts recommended)4-φ15 holes (for fixing bolts)

Cleaning port tightening caution nameplate

BoltCaution nameplate

(Fitted with a vinyl cap at shipment)Rc⅜DR

(Fitted with a vinyl cap at shipment)Rc¾P

1-1

1-2

(Plugged (with O-ring) at shipment)Suction port: Rc1

Pressure indication and operation panel

(620) (40)(40)

(Fitted with a vinyl cap at shipment)Rc¾P

Foundation plate (Option)(E-SUTPLATE-2)

Optional port: Rp⅜

Optional port: Rp½

(Fitted with a vinyl cap at shipment)

Rc1-½T

(plugged at factory)Rc1-¼T

(Fitted with a vinyl cap at shipment)

Rp¾ (above oil level)DR

(Manifold bracket mount)4-M8

(∗ ): Dimensions for SUT10D8021-30

2-M8 (through hole)Tapped holes for mounting the foundation plate (at 4 locations)

Wing bolt for fastening during transportation (at 1 location on the back)(To be removed before operation)

3

59

106-2

6-18

7

Oil sampling port/Oil drain port: Rc½

164 L (∗100 L)Upper limit (Yellow line)

124 L (∗76 L)Lower limit (Red line)

4

2

1

170150

50

100

32710085 188700

1715

0

382

(∗17

2)

(649

) (∗4

39)

70

10

700530 25

4020

595

208585

95(4

41)

30 30

671

(216

)

(893.5)188.5

Cleaning port

70 155

(50)

(647

) 754

450 50 290 (∗80)790 (∗580)840 (∗630)

Suction air

Suctionair

Safety caution nameplate

Unit nameplate

Safety caution nameplate

Unit nameplate

External dimension diagram

Tankless type

Unit type

Page 26: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

O-38

Specifications

Pressure – Flow rate characteristics (Example)Maximum operating pressure 21 MPa

Maximum discharge rate 110 L/minModel code

Super Unit [Double pump type]

Pressure (MPa)

Flow

rate

(L/m

in)

0 5 10 15 200

10

20

30

40

50

60

70

80

90

100

110

* Operating flow rate at the maximum pressure in continuous operation:16 L/min maximum

* The graph shows actual flow rates (representative values).

SUT00D11021-30 SUT20D11KW-30

37.8

34.9

112 360

1.5 to 20.6

20.6

13.3 to 110

3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)

0 to 60°C (Recommended operating temperature range: 15 to 50°C)

− 200

0 to 40°C

−20 to 60°C

85% RH max. (No condensation)

Indoors (Be sure to secure the unit with bolts.)

Ivory white (Munsell code 5Y7.5/1)

Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel

Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil• Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum

• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.• Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.

To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.• Be sure to connect the ground terminal.

1 channel (1 common contact), dry contact, Contact capacity: DC 30 V, 0.5 A

2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel

Tankless type Unit type

110

5 channels

Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.*3: The unit incorporates a safety valve.*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics” and the description of how to select a unit in the separate catalog for Super Units. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.

75

38.3

Equivalent to 11 kW

Model

External input signal

Motor pump/unitPower supply

AC3 φ 200 V (50 Hz)Rated current

(A)

Usable oil *2

Others

Operating conditions

Operating hydraulic oil temperature

Operating ambient temperature

Storage ambient temperature

Operating ambient humidity

Installation site

AC3 φ 200 V (60 Hz)

AC3 φ 220 V (60 Hz)

Power source breaker setting (A)

Mass (kg)

Standard coating color

Pump unit

Maximum discharge rate (Theoretical value; L/min) *1

Motor capacity (Equivalent kW)Motor capacity

Maximum operating pressure (MPa)

Operating flow rate adjustment range (L/min)

Operating pressure adjustment range (MPa)

Tank capacity (L)

Contact outputExternal

output signalDigital output

SUT00D11021-30P-SUT20D11KW-30

Tankless type Unit type

Page 27: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

OIL

CO

OLI

NG

EQ

UIP

ME

NT

O

O-39

SUT00D11021-30

P-SUT20D11KW-30

151

819

Motor wiring port (φ28)

AC fan, thermistor wiring port (21)

134

Rc⅜

Suction port: Rc1 ¼

Drain port

11842

168

323

19

199

Unloading portRc¾

170

76.5

496

112

207 24

3

4-14.5 (installation)

228275

132.595.5

170

Discharge portRc1−¼

314

117 204

228

108108

241

15

237

12090

Lower limit: 165 L

(982

)(1

0)60

035

2

1,3762881,088

43 431,002

9

210

850

11

2

1

146

Tank 2: Rc1(Fitted with plastic plug)Drain port: Rc¾

(Fitted with plastic plug)

(Fitted with high-pressure plug)Tank drain port: Rc½ (at 3 locations)

Upper limit: 200 L

838544

Discharge port: Rc1(Fitted with plastic plug)(Fitted with plastic plug)

Tank 1: Rc1-½

942

210

920

155

866

300

1,15

0 Oil level gauge guard

200 L

Super Unit switch board

Safety caution nameplate

OIL HYDRAULIC UNIT

Unit nameplate

Thermometer

DAIKINDAIKIN INDUSTRIES,LTD. MADE IN JAPAN

DAIKIN

G1/2

670 250

80

Leak test by filling waterCertificate nameplate

Wiring port for the user

137

810

5

4

Part No. Name Quantity1 Oil tank 12 Motor pump 13 Oil level gauge 24 Oil filler port with air breather 15 Suction strainer 16 Return filter7 Oil cooler 18 Pressure gauge 19 Thermometer 1

110 Outlet block611 Vibration-absorbing rubber112 Foundation plate113 Fan motor114 Electrical cabinet

1

3

3

Suction air

Suction air

(Refer to Page O-25 for the external dimensions of the control unit.)

External dimension diagram

Tankless type

Unit type

Page 28: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

O-40

Optional parts

The following optional parts can be purchased separately from the Super Unit.These parts are to be mounted by the user.

Base plate setThese parts are used to fasten the Super Unit to a floor surface. The bolts for mounting the unit to the floor should be prepared by the user.

Color AccessoriesModel

E-SUTPLATE-2

Applicable model

[Unit type: Single pump type] SUT03S1507-30 SUT03S3007-30 SUT06S6007-30 SUT10S8007-30 SUT03S1510-30 SUT03S3010-30 SUT03S1516-30 SUT03S4007-30 SUT06S3016-30[Unit type: Double pump type] SUT06D4016-30 SUT06D6021-30 SUT10D6021-30 SUT10D8021-30 SUT16D8021-30

Temperature switchMountsize

Rp ⅜ N/A

Model code

IP65 60°C2 A50 mA

AC100 VDC24 V

25

2-C3

25

2510 30 10

5040

40t3.2

2-C3

25

Level switchMountsizeModel code

E-DLSN-90L-A-10

Rp ½

EHUR-M0701 7 L maximum ClosedE-DLSN-90L-B-10 EHUR-M0701 7 L maximum Open

E-DLSN-170L-A-10SUT06 (with 60 L tank)SUT10 (with 100 L tank)SUT16 (with 160 L tank)

E-DLSN-170L-B-10SUT06 (with 60 L tank)SUT10 (with 100 L tank)SUT16 (with 160 L tank)

ClosedClosedClosed

OpenOpenOpen

E-DLSN-130L-A-10

IP651 Ωmaximum

30 mΩmaximum

0.02A0.05A

AC100/110VDC24V

EHU14/25/30EHUR-M0702SUT03 (with 30 L tank)SUT06 (with 60 L tank)SUT10 (with 100 L tank)SUT16 (with 160 L tank)

E-DLSN-130L-B-10

EHU14/25/30EHUR-M0702SUT03 (with 30 L tank)SUT06 (with 60 L tank)SUT10 (with 100 L tank)SUT16 (with 160 L tank)

45 L maximum75 L maximum

123 L maximum45 L maximum75 L maximum

123 L maximum

7.3 L maximum13L L maximum21 L maximum50 L maximum83 L maximum

135 L maximum7.3 L maximum13 L maximum21 L maximum50 L maximum83 L maximum

135 L maximum

ClosedClosedClosedClosedClosedClosed

OpenOpenOpenOpenOpenOpen

N/A

ThermometerSizeModel code Temperature

indication range

0 to 100°C φ45

Thermometerspecification

Bimetal type

List of Compatible ModelsModel code EHUR-M0701-30

Micro separator

E-MSB-110

Model Size

110×60×30

E-DLSN-90L-A-10 *4E-DLSN-90L-B-10E-DLSN-130L-A-10E-DLSN-130L-B-10E-DLSN-170L-A-10E-DLSN-170L-B-10E-MQT83PD-L60X1-1-10E-MQT83PD-L60X1-10E-RBT-100-100LE-RBT-100-200LE-MSB-110

Level switch

Temperatureswitch

Thermometer

Micro separator

EHUR-M0702-30

SUT03S-30

SUT06-30

SUT10-30

SUT16D-30

*4 − − − − −− *4 *7 − − −

*5 − − − − −− *5 *8 *8 *8 *8*6 −− − − − −− *6 *9 *9 *9 *9

− *4*1*1 *7 − − −

*7 *7 *7− − −*7 *7 *7−

EHU14/25/30

−−

−*2

*3

−− − −

Example of installation

E-MQT83PD-L60X1-1-10E-MQT83PD-L60X1-10

E-RBT-100-100LE-RBT-100-200L

Note: *1. Mounted directly at the DR2 port *2. Mounted at the DR1 port with a low-pressure or high-pressure bushing (1 × ⅜) or at the DR2 port with a low-pressure or high-pressure bushing (½ × ⅜) *3. Mounted at the DR2 port with a low-pressure or high-pressure bushing (½ × ¼) *4. Mounted at the DR2 port with a high-pressure bushing (¾ × ½) *5. Mounted at the DR2 port with a low-pressure or high-pressure bushing (¾ × ⅜) *6. Mounted at the DR2 port with a low-pressure or high-pressure bushing (¾ × ¼) *7. Mounted directly at option port Rp½ *8. Mounted directly at option port Rp⅜ *9. Mounted at option port Rp⅜ with a low-pressure or high-pressure bushing (⅜ × ¼)

Ivory whiteMunsell code

5Y7.5/1

Base plate (4 pcs)

Tank fastening bolt (8 pcs)

Plain and spring washers for the above parts (8 pcs each)

Oil level triggering alarms CE standard

Protection class

Contactresistance

Operatingcurrent

Operating voltage

Base plate dimensions

φ15 hole

2-φ10 holes

Oil level triggering alarms CE standardProtection class

Contact resistance

Operating current

Operating voltage

Page 29: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

OIL

CO

OLI

NG

EQ

UIP

ME

NT

O

O-41

Optional parts

Model code

SUT03S1507-30SUT03S1510-30SUT03S1516-30SUT03S3007-30SUT03S3010-30SUT03S4007-30SUT06S3016-30SUT06S6007-30SUT06D4016-30SUT06D6021-30SUT10D6021-30SUT10S8007-30SUT10D8021-30SUT16D8021-30

Tank capacity

Super Unit

30 L

60 L

100 L

160 L

Return filter

Not provided

Provided

Tank capacity

30 L

60 L

100 L

160 L

Return filter

Not provided

Provided

Manifold bracket

Model code

Piping set

Installation of 02 Size Control Systems

Model code

E-SUT03S1507N-PIPE-02E-SUT03S1510N-PIPE-02E-SUT03S1516N-PIPE-02E-SUT03S3007N-PIPE-02E-SUT03S3010N-PIPE-02E-SUT03S4007N-PIPE-02E-SUT06S3016F-PIPE-02E-SUT06S6007F-PIPE-02E-SUT06D4016F-PIPE-02E-SUT06D6021F-PIPE-02E-SUT10D6021F-PIPE-02E-SUT10S8007F-PIPE-02E-SUT10D8021F-PIPE-02E-SUT16D8021F-PIPE-02

Part Configuration

Manifold bracket

Model code

Piping set

Model code Part Configuration

(1)

(2)

(3)

Model code

SUT03S1507-30SUT03S1510-30SUT03S1516-30SUT03S3007-30SUT03S3010-30SUT03S4007-30SUT06S3016-30SUT06S6007-30SUT06D4016-30SUT06D6021-30SUT10D6021-30SUT10S8007-30SUT10D8021-30SUT16D8021-30

Super Unit

E-SUT03BASE-203 (Maximum installable series : 2)[Mountable manifold blocks]BT-103-40 (1 series), BT-203-40 (2 series)

E-SUT06BASE-203 (Maximum installable series : 2)[Mountable manifold blocks]BT-103-40 (1 series), BT-203-40 (2 series)

E-SUT06BASE-403 (Maximum installable series : 4)[Mountable manifold blocks]BT-103-40 (1 series) to BT-403-40 (4 series)

Installation of 03 Size Control Systems

E-SUT03S1507N-PIPE-03E-SUT03S1510N-PIPE-03E-SUT03S1516N-PIPE-03E-SUT03S3007N-PIPE-03E-SUT03S3010N-PIPE-03E-SUT03S4007N-PIPE-03E-SUT06S3016F-PIPE-03E-SUT06S6007F-PIPE-03E-SUT06D4016F-PIPE-03E-SUT06D6021F-PIPE-03E-SUT10D6021F-PIPE-03E-SUT10S8007F-PIPE-03E-SUT10D8021F-PIPE-03E-SUT16D8021F-PIPE-03

(1)

(2)(3)

(4)

(3)

E-SUT03BASE-402E-SUT06BASE-302E-SUT06BASE-602E-SUT03BASE-203E-SUT06BASE-203E-SUT06BASE-403

Model code Maximum installable series

4-series3-series6-series2-series2-series4-series

Accessories

- Bracket body 1 pc- Hexagon bolt (M8 × 16) 4 pcs- Flat washer (M8) 4 pcs

For mounting the manifoldHexagon socket head cap bolt, 2 pcs(M8 × 85)

For mounting the manifoldHexagon socket head cap bolt, 4 pcs(M8 × 105)

Bracket/Piping Set for Manifolds

Component parts Manifold bracket

In order to install a control system on the Super Unit, select a bracket and piping set for the manifold according to the control system’s size and number of series. Please prepare a manifold block separately.

E-SUT03BASE-402 (Maximum installable series: 4)[Mountable manifold blocks]BT-102-50 (1 series) to BT-402-50 (4 series) or BT-102-50-140 (1 series) to BT-402-50-140 (4 series)

E-SUT06BASE-302 (Maximum installable series: 3)[Mountable manifold blocks]BT-102-50 (1 series) to BT-302-50 (3 series) or BT-102-50-140 (1 series) to BT-302-50-140 (3 series)

E-SUT06BASE-602 (Maximum installable series: 6)[Mountable manifold blocks]BT-102-50 (1 series) to BT-602-50 (6 series) or BT-102-50-140 (1 series) to BT-602-50-140 (6 series)

Page 30: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

O-42

Optional parts

Piping set

For installing 02 size control systems For installing 03 size control systems

For installing 03 size control systems

1Part Configuration

2Part Configuration

3

2

1

4

8

756

* The external shape differs depending on the model.

* The external shape differs depending on the model.

Name Quantity Tightening torque (N⋅m)

E-SUT03S1507N-PIPE-02E-SUT03S1510N-PIPE-02E-SUT03S1516N-PIPE-02E-SUT03S3007N-PIPE-02E-SUT03S3010N-PIPE-02

Model codeHydraulic hose 1 54.0 to 66.0Hose adaptor (straight) 1 43.0 to 47.5Hose adaptor (elbow) 1 43.0 to 47.5― ― ―Steel pipe 1 100.0 to 120.0Steel piping joint (straight) 1 28.5 to 33.0Steel piping joint (elbow) 1 28.5 to 33.0Bushing 1 95.0 to 110.0Installation guide 1 ―

123456789

E-SUT03S4007N-PIPE-02

Hydraulic hose 1 54.0 to 66.0Hose adaptor (straight) 1 64.0 to 70.0Hose adaptor (elbow) 1 43.0 to 47.5― ― ―Steel pipe 1 100.0 to 120.0Steel piping joint (straight) 1 28.5 to 33.0Steel piping joint (elbow) 1 28.5 to 33.0Bushing 1 95.0 to 110.0Installation guide 1 ―

123456789

Name Quantity Tightening torque (N⋅m)

E-SUT03S1507N-PIPE-03E-SUT03S1510N-PIPE-03E-SUT03S1516N-PIPE-03E-SUT03S3007N-PIPE-03E-SUT03S3010N-PIPE-03

Model codeHydraulic hose 1 54.0 to 66.0Hose adaptor (straight) 1 43.0 to 47.5Hose adaptor (elbow) 1 64.0 to 70.0Bushing

Steel pipe 1 247.0 to 286.01 110.0 to 120.0

Steel piping joint (straight) 1 95.0 to 110.0Steel piping joint (elbow) 1 57.0 to 66.0― ―Installation guide 1 ―

123456789

Hydraulic hose 1 108.0 to 132.0Hose adaptor (straight) 1 64.0 to 70.0Hose adaptor (elbow) 1 110.0 to 120.0

― ―

Steel pipe 1 247.0 to 286.0Steel piping joint (straight) 1 95.0 to 110.0Steel piping joint (elbow) 1 57.0 to 66.0―

―Installation guide 1 ―

123456789

E-SUT03S4007N-PIPE-03

Name Quantity Tightening torque (N⋅m)

E-SUT06S3016F-PIPE-02

Model codeHydraulic hose 1 54.0 to 66.0Hose adaptor (straight) 1 43.0 to 47.5Hose adaptor (elbow) 1 43.0 to 47.5― ― ―

― ― ―

Steel pipe 1 100.0 to 120.0Steel piping joint (elbow) 2 28.5 to 33.0Bushing 1 57.0 to 66.0Plug 1 95.0 to 110.0Installation guide 1 ―

123456789

Steel piping joint (elbow) 2 95.0 to 110.0

Plug 1 95.0 to 110.0Installation guide 1 ―

6789

Name Quantity Tightening torque (N⋅m)

E-SUT06S3016F-PIPE-03

Model codeHydraulic hose 1 54.0 to 66.0Hose adaptor (straight) 1 43.0 to 47.5Hose adaptor (elbow) 1 64.0 to 70.0BushingSteel pipe 1 247.0 to 286.0

1 110.0 to 120.0

12345

3

2

6

5

7

Mounted in the port at the back of the return filter

4

8

61

For installing 02 size control systems

Page 31: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

OIL

CO

OLI

NG

EQ

UIP

ME

NT

O

O-43

Optional parts

Piping set

For installing 02 size control systems

For installing 03 size control systems

For installing 03 size control systems

3Part Configuration

4Part Configuration

* The external shape differs depending on the model.

* The external shape differs depending on the model.

Name Quantity Tightening torque (N⋅m)

E-SUT06S6007F-PIPE-02E-SUT06D4016F-PIPE-02E-SUT06D6021F-PIPE-02E-SUT10D6021F-PIPE-02

Model codeHydraulic hose 1 54.0 to 66.0Hose adaptor (straight) 1 64.0 to 70.0Hose adaptor (elbow) 1 43.0 to 47.5

― ― ―

High-pressure bushing 1 110.0 to 120.0Steel pipe 1 100.0 to 120.0Steel piping joint (elbow) 2 28.5 to 33.0Low-pressure bushing 1 57.0 to 66.0

95.0 to 110.0Plug 1

123456789

E-SUT10S8007F-PIPE-02E-SUT10D8021F-PIPE-02E-SUT16D8021F-PIPE-02

Hydraulic hose 1 54.0 to 66.0Hose adaptor (straight) 1 43.0 to 47.5Hose adaptor (elbow) 1 43.0 to 47.5

Steel pipe 1 100.0 to 120.0Steel piping joint (elbow) 2 28.5 to 33.0Low-pressure bushing (small) 1 57.0 to 66.0

142.5 to 165.0Low-pressure bushing (large) 1 114.0 to 132.0

High-pressure bushing 1 110.0 to 120.0

Plug 1

123456789

Installation guide 1 ―10

Name Quantity Tightening torque (N⋅m)

E-SUT06S6007F-PIPE-03E-SUT10D6021F-PIPE-03

Model codeHydraulic hose 1 108.0 to 132.0Hose adaptor (straight) 1 110.0 to 120.0Hose adaptor (elbow) 1 110.0 to 120.0

Steel pipe 1 247.0 to 286.0Steel piping joint (elbow) 2 57.0 to 66.0

95.0 to 110.0― ―

―― ―

―― ―

Plug 1

123456789

Installation guide 1 ―10 Installation guide 1 ―10

Hydraulic hose 1 108.0 to 132.0Hose adaptor (straight) 1 110.0 to 120.0Hose adaptor (elbow) 1 110.0 to 120.0― ― ―

Steel pipe 1 247.0 to 286.0Steel piping joint (elbow) 2 57.0 to 66.0Bushing 1 114.0 to 132.0

142.5 to 165.0― ―Plug 1

123456789

Installation guide 1 ―10

E-SUT10S8007F-PIPE-03E-SUT10D8021F-PIPE-03E-SUT16D8021F-PIPE-03

Name Quantity Tightening torque (N⋅m)

E-SUT06D4016F-PIPE-03E-SUT06D6021F-PIPE-03

Model codeHydraulic hose 1 108.0 to 132.0Hose adaptor (elbow) 2 110.0 to 120.0Female-male elbow 1 110.0 to 120.0

Steel piping joint (elbow) 2 57.0 to 66.0Steel pipe 1 247.0 to 286.0

Plug 1 95.0 to 110.0Installation guide 1 ―

1234567

6

3

7

2

4

8

6

95

1

Mounted in the port at the back of the return filter

4

5

2

3

2

15

6 Mounted in the port at the back of the return filter

Page 32: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

O-44

Handling

Ambient conditions

Hydraulic oil

Installation and piping

Electric wiring

Other precautions

The following are the minimum requirements for use of the Super Unit.For details, refer to the unit’s Instruction Manual.

1. Use general petroleum hydraulic oil (R&O) or wear-resistant hydraulic oil.Hydrous or synthetic oil cannot be used.

2. Use hydraulic oil equivalent to ISO VG32 to 68 and operate the unit within an oil viscosity range from 15 to 400 mm2/s and a tank oil temperature from 0 to 60°C. The recommended operating range is from 15 to 50°C (20 to 200 mm2/s).

3. Ensure the degree of contamination of the hydraulic fluid is within the NAS 9 class (within NAS 10 class for 7 MPa and lower).

1. Ambient temperature: 0 to 40°C, ambient humidity: 85%RH maximum (with no condensation), altitude: 1,000 m maximum, to be used indoors

1. This hydraulic unit mounts the motor pump using vibration-absorbing rubber to prevent pump vibration being transmitted to the unit.

2. The unit is a stationary type. Fix it with bolts on a level location that is free of vibration.3. Keep obstacles that will obstruct air intake and emission at least 100 mm away from the end face of the unit.

Install the unit at a location with good air flow so that heated air can be vented.4. Use hoses for piping to provide flexibility.5. Before operating the unit, be sure to remove the wing bolt and spacer for protecting the rubber vibration isolator.

If you fail to do so, the noise and vibration may be excessive.6. Be sure to secure the space required to access the unit during electrical wiring at the noise filter box or control unit

side.

1. Install a no-fuse breaker and a ground fault interrupter compliant with European Standard EN60947-2 in the main power supply of this hydraulic unit, to protect the electrical circuits against shorting and overcurrent, and to prevent electric shocks.

2. Use suitable electric cable in accordance with the power supply capacity.3. Be sure to provide a ground connection with a grounding resistance of 100 Ω maximum, and connect the grounding

wire directly with no breaker in the line.4. Take care not to leave waste metal such as screws and cutting chips, combustible matter such as wood waste or

oil, or wiring debris inside the controller.5. Use a commercial power supply for the power source. The use of an inverter power supply may cause burn damage

to the unit.6. Before accessing the interior of the controller, turn the unit’s power supply OFF. Make sure that the circuit is turned

OFF using the circuit breaker for the primary power supply, and then wait at least 5 minutes.

1. If a failure occurs in the hydraulic unit, the system indicates an alarm and stops.2. If failure or malfunction of this unit is expected to cause death or pose a danger to human beings, adopt appropriate

safety measures in the facilities. If this unit is used in an important facility, also adopt appropriate safety measures in the facility to ensure that a failure of the equipment will not lead to a serious accident or loss.

3. It takes approximately 3 seconds for this hydraulic unit to start up after being powered ON.Depending on the piping conditions, the unit may take longer to increase the pressure to the pressure switch&squot;s preset level, resulting in pressure switch signal output. In this case, set the machine up so that it will not accept this alarm output during this period.

4. Do not turn the power OFF/ON with the main power breaker frequently. It may damage inverter components.(To start and stop the unit, use the start/stop signal.)

Page 33: (in the pressure holding time compared with Daikin ... · (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

OIL

CO

OLI

NG

EQ

UIP

ME

NT

O

O-45

Overview of Super Unit Model Change Transition Points

Design No.

Design No. 10 Design No. 11 Design No. 20 Design No. 30

Spe

cific

atio

ns

Paint color

With 3.7 to 5.0 kW tank

Blue (Munsell code 10B3/8)

Ivory white (Munsell code 5Y7.5/1)

Other than aboveIvory white

(Munsell code 5Y7.5/1)

Operating ambient temperature 0 to 35°C 0 to 40°C

Power supply2.2 to 5.0 kW Three-phase AC200/220 V

Single phase AC230 V also available with non-standard types

(However, the pressure – flow rate range contracts.)

Other than above Three-phase AC200/220V Three-phase AC200/220V only

Multi-stage pressure/flow rate control

3.7 to 5.0 kW 4-pattern16-pattern

Other than above 16-pattern

Communication functions

3.7 to 5.0 kW RS485 available with non-standard types RS232C is set as an option.RS485/RS422, etc., are available

with non-standard types.Other than above RS232C option setting

Separation of power supplies for the power system and control system

2.2 to 7.0 kW No separation Optionally available

Other than above No separation

Compliance with CE2.2 to 2.8 kW Available with non-standard types

Available with all modelsOther than above Not available

Analog I/O control Available with non-standard typesOptionally available with all single

pump modelsOptionally available

Improved environmental resistance performance

11 kW Available with non-standard types Electronic parts compatible with sulfides adopted for all modelsOther than above Not available

Unit external dimensions - Approximately the same

Unit cover

With 3.7 to 5.0 kW tank Equipped as standardEquipped as standard

(discharge position changed)Optionally available

With 7.0 kW tank Equipped as standard Optionally available

Other than above Not equipped

Controller cover Not equipped Optionally available

Noise filter Featured as standard

DCL (direct current reactor) Featured as standard Optionally available

Water fill/water leak test compliant tanks Available with non-standard types Optionally available

Accessories (level, temperature switch, thermometer, microseparator)

Available with non-standard types Optionally available

Com

patib

ility

Screw and wiring hole sizes of power/signal line terminal blocks

No change

Discharge / tank / drain port hole diameter No change

Power supply line / signal line wiring port positions

2.2 to 5.0kW No change Changed

Other than above No change

Discharge / tank / drain port hole diameter

3.7 to 5.0 kW - Return filter changed Discharge ports changed Changed

2.2, 2.8, 7.0 kW - Changed

11.0 kW No change