ind-ch-01-en3-13flowmetertechnologychart.pdf
TRANSCRIPT
-
7/27/2019 IND-CH-01-EN3-13FlowMeterTechnologyChart.pdf
1/1
Flow Meter Technology Comparison
Technology Benets Installation Considerations Badger Meter
Products
Insertion Impeller 1% accuracy*
0.5% repeatability
60:1 turn-down ratio
Minimal pressure drop
Hot tap into operational pipe
Retract for maintenance without shutting
down system
Easy-to -install saddles can eliminate the
need to weld
Mechanical meter has moving parts
to maintain
Requires 10 pipe diameters upstream and
5 diameters downstream
Available for pipes 1-1/240"
SDI (1-1/236")
220 (240")
In-line Impeller 12% accuracy dependingon model*
0.30.5% repeatability depending
on model
15:1 turn-down ratio
Minimal pressure drop No adjustments needed for
meter alignment
Easily threaded or glued into
the pipe
Mechanical meter has moving parts
to maintain
Requires 10 pipe diameters upstream and
5 diameters downstream Plumbing must be drained where the meter
is being installed
Requires cutting pipe and
welding flanges
Available for pipe diameters 1/24"
380 Btu Meter (3/42")
735 (1/21")
4000 (1/21")
228/250B (1/21-1/2")
228PV (1-1/24")
In-line Electromagnetic 0.25% accuracy* 0.1% repeatability
250:1 or better turn-down ratio
depending on pipe diameter
No pressure drop
Different liner and electrode types
available for compatibility with
different fluid types
No moving parts to maintain
or replace
Plumbing must be drained where the meter
is being installed
Larger physical profile
Requires 3 pipe diameters upstream and
5 pipe diameters downstream
Available for pipe diameters 1/454"
M2000 (1/454")
Clamp-on Ultrasonic 1% accuracy* 0.5% repeatability
12:152:1 turn-down ratio
depending on pipe diameter
and material
No pressure drop
One size fits a wide range of types
and is therefore convenient to keep
in inventory
Ethernet network connectivity
No moving parts to maintain
or replace
Add onto operational pipe without
cutting pipe
Requires 10 pipe diameters up stream and
up 5 pipe diameters downstream
Pipe needs to be prepared to
accommodate bonding of transducers
using acoustical couplant
Available for pipe diameters 1/2100+"
TFX Ultra (1/2100+")
Portable Clamp-on
Ultrasonic
1 to 2% accuracy*
0.1% repeatability
12:152:1 turn-down ratio
No pressure drop
Convenient for temporary
measurements
No moving parts to maintain or
replace
No fluid compatibility issue
One size fits a wide range of
types and is convenient to keep
in inventory
Portable: Add onto operational pipe
without cutting pipe
Requires 10 pipe diameters upstream and
5 pipe diameters downstream
Pipe needs to be prepared to temporarily
affix transducers using acoustical couplant
Available for pipe diameters 1/2100+"
DXN (1/2100+")
*Accuracies are typical or volumetric ow aspect o the heat meters and do not include the uncertainty o diferent temperature
measures. Accuracies also do not represent rating degradation required or low ow conditions. Reer to product documentation or
specic guidance.
IND-CH-01-EN (March 2013)
Rev. 2