Industrial machinerydisconnect means
DO YOUR PANELS
STILL COMPLY WITH THE
NORTH AMERICAN
STANDARDS ?
NFPA 79
DO YOUR PANELS
STILL COMPLY
NFPA 79NEW in UL 508A
doc_107013.indd 1 14/04/09 11:26:44
2
The changes in UL508A, effective March 1, 2007 and NFPA 79 impact the design and construction of your equipment.
Important modifications concern major safety issues, the disconnect means and the interlocking of the enclosure door. Here are SOCOMEC solutions to complain with the relevant standars.
2. The disconnect means is not closable with the enclosure door open, unless an interlock is operated by a deliberate action...
Socomec solution
1. Push
Door open: From Off to ON
From Off to On it is necessary to push the handle this deliberate action permit to turn and switch On. this deliberate action is necessary as in most of the case there is no padlock on the switch when somebody open the door of an enclosure..
2. Turn
From On to Off
From Off to ON it is necessary to push the handle, this deliberate action permit to turn and switch ON.That is a major safety issue; switching ON directly with out any other action is extremely dangerous.The use of a padlock does not comply with the request of the standard, when the door of a panel is opened there is generally no padlock and anybody can turn the switch ON.
FUS
ER
456
A -
FU
SE
R 4
55 A
The changes in
NFPA 79
NEW in
UL 508A
1. The disconnect shall be operable independent of the position of the door...
An operating mechanism for the disconnecting means shall be operable independent of the door position without the use of accessory tools or devices;
UL508A; Paragraph 66.6.3 c.
The disconnect must «Be operable, by qualified persons, independent of the door position without the use of accessory tools or devices.
NFPA 79; Paragraph 5.3.3.1 (5) T
Socomec solutionA red handle is fitted on the front shaft, it allows the operation when the door is open. The standard external handle allows the operation when the door is closed.The internal handle is part of the NFPA 79 kit.These optional accessories are available for non fusible disconnect from 30A to 400A and fusible disconnect from 30A to 600A. C
OFF
333
A -
FU
SE
R 4
55 A
Door close: Operat ion with the external handle throu-gh the door
Door open: A strong optional kit with a handle directly fitted on the shaft of the switch allows the operation when the door is open
The disconnecting means is not closable with the enclosure door open, unless an interlock is operated by deliberate action.
UL508A, Paragraph 66.1.5
The interlocking means shall fulfill the following requirement.(3) Prevent closing of the disconnecting means while the enclosure door is open, unless an interlock is operated by deliberate action.
NFPA 79; Paragraph 6.2.3.1.2
These requirements cover industrial control panels for industrial machinery. The following types of machines are identified as industrial machinery:
UL508A
Standard for industrial control panels
• Metalworking machine tools• Plastics machinery• Wood machinery• Assembly machines;• Material handling machines• Inspection and testing machines
Industrial Machinery - Section 65 and 66
Disconnect and Disconnecting means = Load Break Switches - Fusible Disconnect switches = Fuse Combination Switches
doc_107013.indd 2 14/04/09 11:26:51
3
3. The disconnect means shall be able to be locked in the open position independent of the door position...
Socomec solution
Door close: The external through the door handle is padlocked* when locked closing of the disconnector is not possible
Door open: Door open a strong metallic padlock kit allow up to 3 padlock. The padlocking means is easily accessible, when locked closing of the disconnector is not possible
FUS
ER
447
B -
FU
SE
R 4
53 A
An operating mechanism for the disconnecting means shall be able to be locked in the off position independent of the door position; and when locked, closing of the disconnect is not possible.
UL508A Paragraph 66.6.3 d.
The circuit disconnecting device shall be provided with a permanent means permitting it to be locked in the off position only independent of the door position. When locked, remote as well as local closing shall be prevented.
NFPA 79 Paragraph 5.3.3.1(3)
4. The interlocking of the enclosure door shall be provided with means to defeat the interlock without removing the power...The interlocking means required by 66.1.5 shall be provided
with all the following:a) Means to defeat the interlock without removing power and which requires the use of a tool to operate;(c) Reactivated automatically when all the doors are closed.Added 66.1.5.1 effective March 1, 2007
UL508A; Paragraph 66.1.5.1
NFPA 79; Paragraph 6.2.3.1.2 states that «The (enclosure) interlocking means shall meet the following requirements :(1) Utilize a device or tool... to allow qualified persons to defeat
the interlock(2) Be reactivated automatically when the door is closed
NFPA 79; Paragraph 6.2.3.1.2
UL508 or UL98UL98; Enclosed and dead front Switches (equivalent to CSA-C22.2 no 4)
These products are used as disconnecting means without restrictions; they are heavy duty products requiring 2 inches minimum of creepage distance, which gives a maximum safety for users and installation. The short circuit withstand of those products goes up to 200 kA !
UL508; Industrial Control Equipment (equivalent to CSA-C22.2 no 14)
A manual motor controller marked «Suitable as motor discon-nect « can only be used for the local disconnection of a motor
Dis
conn
ect S
witc
h
UL
98 /
UL
489
Fuse
s
Cont
acto
r
Ove
rload
rela
y
UL
508
Man
ual M
otor
Con
trol
ler
“Sui
tabl
e as
Mot
or D
isco
nnec
t”
Mot
or
UL9
8 N
on F
usib
le
Dis
conn
ect
Switc
hes
SIRC
O &
SIR
CO
M3
Fusi
ble
Dis
conn
ect
Switc
hes
FUSE
RBLO
C
Con
tact
or
Ove
rload
rela
y
UL5
08
UL
508
Man
ual
Mot
or C
ontro
ller
«sui
tabl
e as
Mot
or
Dis
conn
ect»
SI
RCO
M1
& M
2
Mot
or
Socomec solution
A tool allows to defeat the interlock without removing power. The interlocking is reactivated automatically when all the doors are closed.
CO
FF 3
33 A
- C
OFF
345
A -
CO
FF 3
32 A
doc_107013.indd 3 14/04/09 11:27:00
www.socomec.com Réf
. DO
C 1
0701
3 -
04/0
9 -
Pho
to :
Mar
tin B
ernh
art -
Réa
lisat
ion
: SO
CO
ME
C S
ervi
ce C
omm
unic
atio
n -
IXO
C
OU
V 1
63 A
VALID FOR FRANCE
HEAD OFFICE & INTERNATIONAL SALES DEPARTMENT
SOCOMECS.A. SOCOMEC capital 11 302 300 ER.C.S. Strasbourg B 548 500 1491, rue de Westhouse - B.P. 60010 F - 67235 Benfeld Cedex Tel. +33 (0)3 88 57 41 41 Fax +33 (0)3 88 74 08 [email protected]
Non contractual document. © 2009, Socomec SA. All rights reserved.
Motor controller: Sirco M1 & M2 UL508 - CSA 22.2§14 Suitable as motor disconnect
SIR
CM
113
A
SIR
CM
119
A
CO
FF 3
36 A
From 16A to 80A From 3 to 8 poles External and direct operation
Disconnect switches without fuses UL98 - UL 489 & CSA 22.2§4
SIR
CM
100
A
SIR
CM
032
C
FER
RA
Z 00
8 C
From 30A to 1200A3 and 4 polesExternal and direct operationFlange operationNFPA 79 solution
Disconnect switches with fuses UL98 - UL489 & CSA 22.2§4
FUS
ER
164
A
FUS
ER
709
A
FER
RA
Z 00
4 B
From 30A to 800AFrom 2 to 4 polesExternal and direct operationFlange operationNFPA 79 solution
Manual Transfer Switches UL1008 / UL98 & CSA 22.2§4
SV
R 1
12 B
SV
R 9
9 B
From 100A to 400A UL1008From 600A to 1200A UL98 & CSA 22.2§4External and direct operation
IN USA, CANADA & MEXICOSOCOMEC Inc222 Third Street, Suite 1221 Cambridge, MA02142 - USATel. +617 245 0447Fax +617 245 [email protected]
IN GERMANYSOCOMEC GmbHAm Hardtwald 11 D - 76275 Ettlingen Tel. +49 (0)7243 65 29 2 0Fax +49 (0)7243 65 29 2 13 [email protected]
doc_107013.indd 4 14/04/09 11:27:20