Modultec- Switching System
Industrial RelayRF-3
• 11pole, for Socket BSF-11• 3 Switching contacts 10A
© Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10 ZR/45
®
Description
• Industrial relay of proven design• Mechanical switched position indicator and manual but-
ton• Available in all rated voltages• Functions as a time relay when combined with a Modul-
tec-Systems time module
Contact Arrangement
A1
A2 31 21 11
34 32 24 22 14 12
ZR/46 © Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10
RF
-6.D
-01G
Technical Data
Number of contacts 3 UK 10ARated voltages VAC 12; 24; 48;
110; 220; 240VDC 12; 24; 48; 110
Rated breaking capacity 2500VAContacts Ag-NiMechanical endurance AC: 20x1’000x10³
DC: 50x1’000x10³Ambient temperature -40 bis +70°CSwitched position inicator mechanicalManual button at hand
Dimension Sheet
Order Information
RF-3 12ACRF-3 24ACRF-3 48ACRF-3 110ACRF-3 220ACRF-3 240ACRF-3 12DCRF-3 24DCRF-3 48DCRF-3 110DC
51
36,2
© Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10 ZR/21
Time Relays
MRAB• Multiple voltage
• 6 Programmable functions
• 6 Time ranges
Terminal Designations
Programming
14 12 34 32
11 31
Operating LED
Output terminal
Range adjustment
Time range selection
Function selectorswitch
Description
FunctionsA = On-delayB = Off-delayD = Interval delayFh = Flashing (pulse starting)Fd = Flashing (pause starting)C = Breaking-pulse
Time Ranges0,1 – 1s1 – 10s10 – 100s1 – 10m10 – 100m1 – 10h
Control MethodsPower supply Voltage controlledPotential-free contact
Function
Power SupplyMultiple voltage24-240 VAC/DC(without galvanic isolation)
sd
t
sd
t
sd
t
sd
t t t t
D-Function: When “s” closes “d” is ener-gised instantaneously and is de-energisedafter completion of the time period “t”
sd
sd
t
Fd-Function: When “s” closes “d” is ener-gised after completion of the time period “t”and remains energised for the time period“t”. This cycle repeats itself until “s” opens.
C-Function: When “s” opens “d” is ener-gised instantaneously and is de-energisedafter completion of the time period “t”
Fh-Function: When “s” closes “d” is ener-gised instantaneously and is de-energisedafter completion of the time period “t” and remains de- energised for the time period“t”. This cycle repeats itself until “s” opens
t t t t t
A-Function: When “s” closes “d” is ener-gised after completion of the time period “t”and is de-energised instantaneously when“s” opens.
B-Function: When “s” closes “d” is energi-sed instantaneously and when “s’ opens isde-energised after completion of the time period “t”
®
ZR/22 © Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10
MR
AB
- 6
.E -
09G
Technical Data
Timing CharacteristicsRange accuracy +10% Time adjustment analogue Adjustability linear Repeat accuracy ±0,2 % or 10msTemperature stability ±0,02 %/°C ± 10msVoltage stability ±0,2 % or 20ms
Voltage CharacteristicsVoltage variation –20%/+10%Frequency 50/60HzGalvanic isolation none
ControlRecovery time >60ms Resetting time >50msMin. activating time >40ms Cable impedance <100 Ohm
OutputType Relay 2 C/O Load capacity 250VAC; 6A ohmicDisplay LED yellow
OperationDisplay LED greenOperating temperature –20°C to +60°C Storage temperature –20°C to +80°CPower consumption max. 4VA
Order Information
Control Methods
MRAB
A2 A1 21 22 24
Un s
Controlled by power supply forfunctions A, D, Fh, Fd
A2 A1 21 22 24
Uns
Controlled by potential-freecontact for functions B, C
A2 A1 21 22 24
Un
Controlled by voltage for functions B, C
s
–~ +~
© Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10 ZR/23
Description
FunctionsA = On-delayB = Off-delayD = Interval delayFh = Flashing (pulse starting)Fd = Flashing (pause starting)C = Breaking-pulse
Time Ranges0,1 – 1s1 – 10s10 – 100s1 – 10m10 – 100m1 – 10h
Control MethodsPower supply Voltage controlledPotential-free contact
Function
Time Relays
MRAB1S• Multiple voltage
• 6 Programmable functions
• Immediate contact
Power SupplyMultiple voltage24-240 VAC/DC(without galvanic isolation)
Terminal Designations
Programming
14 12 34 32
11 31
Operating LED
Range adjustment
Time range selection
Function selectorswitch
Output terminal
sd
t
sd
t
sd
t
sd
t t t t
D-Function: When “s” closes “d” is ener-gised instantaneously and is de-energisedafter completion of the time period “t”
sd
sd
t
Fd-Function: When “s” closes “d” is ener-gised after completion of the time period “t”and remains energised for the time period“t”. This cycle repeats itself until “s” opens.
C-Function: When “s” opens “d” is ener-gised instantaneously and is de-energisedafter completion of the time period “t”
Fh-Function: When “s” closes “d” is ener-gised instantaneously and is de-energisedafter completion of the time period “t” and remains de- energised for the time period“t”. This cycle repeats itself until “s” opens
t t t t t
A-Function: When “s” closes “d” is ener-gised after completion of the time period “t”and is de-energised instantaneously when“s” opens.
B-Function: When “s” closes “d” is energi-sed instantaneously and when “s’ opens isde-energised after completion of the time period “t”
®
ZR/24 © Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10
MR
AB
1S -
6.E
- 0
9G
Technical Data
Timing CharacteristicsRange accuracy +10% Time adjustment analogueAdjustability linearRepeat accuracy ±0,2% or 10msTemperature stability ±0,02%/°C ± 10msVoltage stability ±0,2% or 10ms
Voltage CharacteristicsVoltage variation –20%/+10%Frequency 50/60HzGalvanic isolation none
ControlRecovery time >60msResetting time >50msMin. activating time >40ms Cable impedance <100 Ohm
OutputType Relay 2 C/OLoad capacity 250VAC; 6A ohmicDisplay LED yellow
OperationDisplay LED greenOperating temperature –20°C to +60°CStorage temperature –20°C to +80°CPower consumption max. 4VA
Order Information
Control Methods
MRAB1S
A2 A1 21 22 24
Un s
Controlled by power supply forfunctions A, D, Fh, Fd
A2 A1 21 22 24
Uns
Controlled by potential-freecontact for functions B, C
A2 A1 21 22 24
Un
Controlled by voltage for functions B, C
–~ +~s
© Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10 ZR/19
Description
FunktionenAi = On-delay (impulse, 1 cycle)A = On-delayDi1Z = Interval delay (impulse, 1 cycle)Di = Interval delay (impulse)Fd = Flashing (pause starting)D = Instantaneous delay
Time Ranges0,1 – 1s1 – 10s10 – 100s1 – 10m10 – 100m1 – 10h
Control MethodsPower supply Voltage controlledPotential-free contact
Function
Time Relays
MRADI• 6 Programmable functions
• Multiple voltage
• Impulse controlled
®
Power SupplyMultiple voltage24-240 VAC/DC(without galvanic isolation)
sd
t
t t
sd
t t t t t t
Fd-Function: When “s” closes “d” is ener-gised after completion of the time period “t”and remains energised for the time period“t”. This cycle repeats itself until “s” opens.
sd
t
D-Function: When “s” closes “d” is ener-gised instantaneously and is de-energised after completion of the time period “t”
Terminal Designations
Programming
14 12 34 32
11 31
A-Function: When “s” closes “d” is ener-gised after completion of the time period “t”and is de-energised instantaneously when“s” opens.
sdUn
t tAi-Function: When “s” closes “d” is ener-gised after completion of the time period“t”. If “s” is actuated after the time has started it has no effect on the function.
Operating LED
Range adjustment
Time range selection
Function selectorswitch
sdUn
Di1Z-Function: When “s” closes “d” is ener-gised instantaneously and is de-energisedafter completion of the time period “t”. If “s”is actuated after the time has started it hasno effect on the function.
t t
sdUn
Di-Function: When “s” closes “d” is energisedinstantaneously and is de-energised after com-pletion of the time period “t”. If “s” is actuatedafter the time has started it has no effect on thefunction. If “s” re-closes after the completion ofthe time period “t” the function is stopped.
Output terminal
ZR/20 © Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10
MR
AB
I - 6
.E -
09G
Technical Data
Timing CharacteristicsRange accuracy +10% Time adjustment analogue Adjustability linear Repeat accuracy ±0,2% or 10msTemperature stability ±0,02%/°C ± 10msVoltage stability ±0,2% or 20ms
Voltage CharacteristicsVoltage variation –20%/+10%Frequency 50/60HzGalvanic isolation none
ControlRecovery time >60ms Resetting time >50msMin. activating time >40ms Cable impedance <100 Ohm
OutputType Relay 2 C/O Load capacity 250VAC; 6A ohmicDisplay LED yellow
OperationDisplay LED greenOperating temperature –20°C to +60°C Storage temperature –20°C to +80°CPower consumption max. 4VA
Order Information
Control Methods
MRADI
A2 A1 21 22 24
Un s
Controlled by power supply forfunctions A, Fd, D
A2 A1 21 22 24
Uns
Controlled by potential-freecontact for functions Ai, A,Di1Z, Di, Fd, D
A22 A1 21 22 24
Un
Controlled by voltage for functions Ai, A, Di1Z, Fd, D
s
–~ +~
Description
FunctionsA = On-delayB = Off-delayD = Instantaneous delayFh = Flashing (pulse starting)Fd = Flashing (pause starting)
Time Ranges0,1 – 99,9s1 – 999s0.1 – 99,9m1 – 999m0,1 – 99,9h1 – 999h
Control MethodsPower supplyPotential-free contact
Function
Time Relays
QRAB• 5 Programmable functions
• 6 Time ranges
• Digital time adjustment
© Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10 ZR/31
Power Supply24-48VAC/DC
115VAC230VAC
U1 (12- 72VAC/DC)U2 (80-240VAC/DC)
Terminal Designations
Programming
14 12 34 32
11 31
Function selector switch
Time range selection
Range adjustment
Operating LED
Output terminal
sd
t
sd
t
sd
t
sd
t t t t
D-Function: When “s” closes “d” is ener-gised instantaneously and is de-energisedafter completion of the time period “t”
sd
Fd-Function: When “s” closes “d” is ener-gised after completion of the time period “t”and remains energised for the time period“t”. This cycle repeats itself until “s” opens.
Fh-Function: When “s” closes “d” is ener-gised instantaneously and is de-energisedafter completion of the time period “t” and remains de- energised for the time period“t”. This cycle repeats itself until “s” opens
t t t t t
A-Function: When “s” closes “d” is ener-gised after completion of the time period “t”and is de-energised instantaneously when“s” opens.
B-Function: When “s” closes “d” is energi-sed instantaneously and when “s’ opens isde-energised after completion of the time period “t”
®
ZR/32 © Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10
QR
AB
- 6
.E -
09G
Technical Data
Timing CharacteristicsTime adjustment digitalAdjustability ±1 digitRepeat accuracy ±0,01% or 40msTemperature stability ±0,001%/°C ± 10msVoltage stability ±0,01% or 10ms
Voltage CharacteristicsVoltage variation<100V ±20%>100V –20%/+10%Frequency 50/60HzGalvanic isolation with U1, U2
ControlRecovery time >60ms Resetting time >50msMin. activating time >40msCable impedance <100 Ohm
OutputType Relais 2UK Load capacity 250VAC; 6A ohmicDisplay LED yellow
OperationDisplay LED greenOperating temperature –20°C to +60°CStorage temperature –20°C to +80°CPower consumption max. 4VA
Order Information
Control Methods
QRAB 24-48ACDCQRAB 115ACQRAB 230ACQRAB-U1QRAB-U2
Un
s
A2 A1 21 22 24
Controlled by power supply for functions A, D, Fh, Fd
Uns
A2 A1 21 22 24
Controlled by potential-free contact for function B
Description
FunctionsA = On-delayB = Off-delayD = Interval delayFh = Flashing (pulse starting)Fd = Flashing (pause starting)C = Breaking-pulse
Time Ranges0,1 – 99,9s1 – 999s0.1 – 99,9m1 – 999m0,1 – 99,9h1 – 999h
Control MethodsPower supply Voltage controlledPotential-free contact
Function
Time Relays
QRP4• 6 Programmable functions
• 6 Time ranges
• Digital time adjustment
© Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10 ZR/33
Power Supply12VDC
24-48VAC/DC115VAC (Transformer)
230VAC (Transformer)
U1 (12- 72VAC/DC)U2 (80-240VAC/DC)
Terminal Designations
Programming
14 12 34 32
11 31
Operating LED
Function selectorswitch
Time range selection
Adjustment range
Output terminal
sd
t
sd
t
sd
t
sd
t t t t
D-Function: When “s” closes “d” is ener-gised instantaneously and is de-energisedafter completion of the time period “t”
sd
sd
t
Fd-Function: When “s” closes “d” is ener-gised after completion of the time period “t”and remains energised for the time period“t”. This cycle repeats itself until “s” opens.
C-Function: When “s” opens “d” is ener-gised instantaneously and is de-energisedafter completion of the time period “t”
Fh-Function: When “s” closes “d” is ener-gised instantaneously and is de-energisedafter completion of the time period “t” and remains de- energised for the time period“t”. This cycle repeats itself until “s” opens
t t t t t
A-Function: When “s” closes “d” is ener-gised after completion of the time period “t”and is de-energised instantaneously when“s” opens.
B-Function: When “s” closes “d” is energi-sed instantaneously and when “s’ opens isde-energised after completion of the time period “t”
®
ZR/34 © Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10
QR
P4
- 6.
E -
09G
Technical Data
Timing CharacteristicsTime adjustment digitalAdjustability ±1 digitRepeat accuracy ±0,01% or 10msTemperature stability ±0,001%/°C ± 10msVoltage stability ±0,01% or 10ms
Voltage CharacteristicsVoltage variation<100V ±20% (with 12V –10%/+20%)>100V –20%/+10%Frequency 50/60HzGalvanic isolation >100V, U1, U2
ControlRecovery time >60ms Resetting time >50msMin. activating time >40ms Cable impedance <100 Ohm
OutputType Relay 2 C/O Load capacity 250VAC; 6A ohmicDisplay LED yellow
OperationDisplay LED greenOperating temperature –20°C bis +60°CStorage temperature –20°C bis +80°CPower consumption max. 4VA
Order Information
Control Methods
QRP4-12DCQRP4-24-48ACDCQRP4-115ACQRP4-230ACQRP4-U1QRP4-U2
Controlled by power supply forfunctions A, D, Fh, Fd
A2 A1 21 22 24
Uns
A2 A1 21 22 24
Uns
Controlled by voltage for functions A, B, D, Fh, Fd, C
A2 A1 21 22 24
Uns
~ ~
Controlled by potential-freecontact for functions A, B, D,Fh, Fd, C
Controlled by voltage for functions A, B, D, Fh, Fd, C
Controlled by voltage for functions A, B, D, Fh, Fd, C
Voltage controlled24-48 VACDC/12VDC U1/U2
Un_~ +~
A2 A1 21 22 24
s
Un_~ +~
A2 A1 21 22 24
s
230/115VAC
© Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10 ZR/41
Description
FunctionsAB = On-delay/Off-delayU1Z = Change-over function (1 cycle)Ud = Change-over function (pause starting)Uh = Change-over function (pulse starting)CD = Making-pulse/Breaking-pulse
Time Ranges0,1 – 99,9s1 – 999s0.1 – 99,9m1 – 999m0,1 – 99,9h1 – 999h
Control MethodsPower supply Potential-free contact
Function
Time Relays
QZMK• 5 Functions
• Stop or Reset function
• Digital time adjustment
Power Supply24-48VAC/DC
115VAC (Transformer)
230VAC (Transformer)
U1 (12- 72VAC/DC)U2 (80-240VAC/DC)
sd
t1 t2
sd
t1 t2
sd
sd
t1 t2 t1 t2
sd CD-Function: When “s” closes “d” is energised
instantaneously and is de-energised after com-pletion of the time period “t1”. When “s” opens“d” is again energised instantaneously and isde-energised after completion of the time peri-od “t2”. (Relay with time “t1”=”t2”)
Uh-Function: When “s” closes “d” is energisedinstantaneously and de-energised after comple-tion of the time period “t1” and remains de-ener-gised for the time period “t2”. This cycle repeatsitself until “s” opens. When the relay is controlledby the power supply the relay is de-energised instantaneously when “s” opens. If the control isby means of an external contact the time alreadystarted is first completed.
t1 t2
Terminal Designations
Programming
14 12 34 32
11 31
AB-Function: When “s” closes “d” is energisedafter completion of the time period “t1” andwhen “s” closes it is de-energised after comple-tion of the time period “t2”. (Relay with time“t1”=”t2”)
Operating LED
Function selectorswitch
Time range selection t1
Stop/Reset
Range adjustment t2
Range adjustment t1
Time range selection t2t1 t2 t1 t2
Mode selector switch
Output terminal
Ud-Function: When “s” closes “d” is energisedafter completion of the time period “t1” and remains energised for the time period “t2”. Thiscycle repeats itself until “s” opens. When the relay is controlled by the power supply the relayis de-energised instantaneously when “s” opens.If the control is by means of an external contactthe time already started is first completed.
U1Z-Function: When “s” closes “d” is energi-sed after completion of the time period “t1” andis de-energised after completion of the time period “t2”. If “s” is actuated after thetime has started it has no effect on the function.If the control is by means of an external contactthe time already started is completed when “s”opens.
®
ZR/42 © Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10
QZ
MK
- 6
.E -
10G
Technical Data
Timing CharacteristicsTime adjustment digitalAdjustability ±1 digitRepeat accuracy ±0,01% or 10msTemperature stability ±0,001%/°C ± 10msVoltage stability ±0,01% or 10ms
Voltage CharacteristicsVoltage variation<100V ±20%>100V –20%/+10%Frequency 50/60HzGalvanic isolation >100V, U1/U2
ControlRecovery time >60ms Resetting time >50msMin. activating time >40msCable impedance <100 Ohm
OutputType Relay 2 C/O Load capacity 250VAC; 6A ohmicDisplay LED yellow
OperationDisplay LED greenTime elapse LED redOperating temperature –20°C to +60°CStorage temperature –20°C to +80°CPower consumption max. 4VA
Order Information
Control Methods
QZMK 24-48ACDCQZMK 115ACQZMK 230ACQZMK-U1QZMK-U2
A2 A1 21 22 24
Un s
Controlled by power supply forfunctions U1Z, Ud, Uh
A2 A1 21 22 24
Uns
Controlled by potential-freecontact for functions AB, U1Z,Ud, Uh, CD(Stop/Reset function)
A2 A1 21 22 24
Uns
Controlled by potential-freecontact for functions AB, U1Z,Ud, Uh, CD
Description
FunctionsA = On-delayB = Off-delayD = Interval delayFh = Flashing (pulse starting)Fd = Flashing (pause starting)C = Breaking-pulse
Time Ranges0,1 – 999,9s1 – 9999s0.1 – 999,9m1 – 9999m0,1 – 999,9h1 – 9999h
Control MethodsPower supply Voltage controlledPotential-free contact Three wire sensor
Function
Time Relays
QZMP• 6 Programmable functions
• 6 Time ranges
• Digital time adjustment
© Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10 ZR/39
Power Supply24-28VAC/DC
115VAC (Transformer)
230VAC (Transformer)
U1 (12- 72VAC/DC)U2 (80-240VAC/DC)
Terminal Designations
Programming
14 12 34 32
11 31
Operating LED
Function selector switch
Time range selection
Time elapse LED
Range adjustment
Output terminal
sd
t
sd
t
sd
t
sd
t t t t
D-Function: When “s” closes “d” is ener-gised instantaneously and is de-energisedafter completion of the time period “t”
sd
sd
t
Fd-Function: When “s” closes “d” is ener-gised after completion of the time period “t”and remains energised for the time period“t”. This cycle repeats itself until “s” opens.
C-Function: When “s” opens “d” is ener-gised instantaneously and is de-energisedafter completion of the time period “t”
Fh-Function: When “s” closes “d” is ener-gised instantaneously and is de-energisedafter completion of the time period “t” and remains de- energised for the time period“t”. This cycle repeats itself until “s” opens
t t t t t
A-Function: When “s” closes “d” is ener-gised after completion of the time period “t”and is de-energised instantaneously when“s” opens.
B-Function: When “s” closes “d” is energi-sed instantaneously and when “s’ opens isde-energised after completion of the time period “t”
®
ZR/40 © Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10
QZ
MP
- 6
.E -
10G
Technical Data
Timing CharacteristicsTime adjustment digitalAdjustability ±1 digitRepeat accuracy ±0,01% or 10msTemperature stability ±0,001%/°C ± 10ms Voltage stability ±0,01% or 10ms
Voltage CharacteristicsVoltage variation<100V ±20%>100V –20%/+10%Frequency 50/60HzGalvanic isolation >100V, U1/U2
ControlRecovery time >60ms Resetting time >50msMin. activating time >40msCable impedance <100 Ohm
OutputType Relay 2 C/O Load capacity 250VAC; 6A ohmicDisplay LED yellow
OperationDisplay LED greenTime elapse LED redOperating temperature –20°C to +60°C Storage temperature –20°C to +80°CPower consumption max. 4VA
Order Information
Control Methods
QZMP 24-48ACDCQZMP 115ACQZMP 230ACQZMP-U1QZMP-U2
Controlled by power supply forfunctions A, D, Fh, Fd
A2 A1 21 22 24
Un
s
A2 A1 21 22 24
Uns
Controlled by voltage for functions A, B, D, Fh, Fd, C
A2 A1 21 22 24
Uns
~ ~
Controlled by potential-freecontact (three wire sensor) forfunctions A, B, D, Fh, Fd, C
NP
NN
AM
UR
Controlled by voltage for functions A, B, D, Fh, Fd, C
Controlled by voltage for functions A, B, D, Fh, Fd, C
Voltage controlled24-48 VACDC U1/U2
Un_~ +~
A2 A1 21 22 24
s
Un_~ +~
A2 A1 21 22 24
s
230/115VAC
Description
FunctionsA = On-delayB = Off-delayD = Interval delayAB = On-delay/Off-delayDi = Interval delay (Impulse)C = Breaking-pulse
Time Ranges0,1 – 99,9s1 – 999s0.1 – 99,9m1 – 999m0,1 – 99,9h1 – 999h
Control MethodsPower supply Voltage controlledPotential-free contact Three wire sensor
Function
Time Relays
QZMR• 6 Programmable functions
• 6 Time ranges
• Digital time adjustment
© Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10 ZR/35
®
Power Supply24-48VAC/DC
115VAC230VAC
U1 (12- 72VAC/DC)U2 (80-240VAC/DC)
sd
t
sd
t
B-Function: When “s” closes “d” is energisedinstantaneously and when “s’ opens is de-ener-gised after completion of the time period “t”
sd
t
sd
t1 t2
D-Function: When “s” closes “d” is energisedinstantaneously and is de-energised after com-pletion of the time period “t”
sd
t
C-Function: Nach Öffnen von s schaltet dunverzögert ein und fällt nach t ab.
AB-Function: When “s” closes “d” is energisedafter completion of the time period “t1” and when“s” closes it is de-energised after completion ofthe time period “t2”. (Relay with time “t1”=”t2”)
Terminal Designations
Programming
14 12 34 32
11 31
A-Function: When “s” closes “d” is energisedafter completion of the time period “t” and is de-energised instantaneously when “s” opens.
Operating LED
Function selectorswitch
Time range selection
Range adjustment
t t
sdUn
Di-Function: When “s” closes “d” is energisedinstantaneously and is de-energised after com-pletion of the time period “t”. If “s” is actuatedafter the time has started it has no effect on thefunction. If “s” re-closes after the completion ofthe time period “t” the function is stopped.
Output terminal
ZR/36 © Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10
QZ
MR
- 6
.E -
10G
Technical Data
Timing CharacteristicsTime adjustment digitalAdjustability ±1 digitRepeat accuracy ±0,01% or 10msTemperature stability ±0,001%/°C ± 10msVoltage stability ±0,01% or 10ms
Voltage CharacteristicsVoltage variation<100V ±20%>100V –20%/+10%Frequency 50/60HzGalvanic isolation >100V, U1, U2
ControlRecovery time >60ms Resetting time >50msMin. activating time >40msCable impedance <100 Ohm
OutputType Relay 2 C/O Load capacity 250VAC; 6A ohmicDisplay LED yellow
OperationDisplay LED greenOperating temperature –20°C to +60°CStorage temperature –20°C to +80°CPower consumption max. 4VA
Order Information
Control Methods
QZMR 24-48ACDCQZMR 115ACQZMR 230ACQZMR-U1QZMR-U2
Controlled by power supply forfunctions A, D
A2 A1 21 22 24
Uns
Controlled by voltage for functions A, B, D, AB, Di, C
A2 A1 21 22 24
Uns
~ ~
A2 A1 21 22 24
Un s NP
N
Controlled by potential-freecontact (three wire sensor) forfunctions A, B, D, AB, Di, C
Controlled by voltage for functions A, B, D, AB, Di, C
Controlled by voltage for functions A, B, D, AB, Di, C
Voltage controlled24-48 VACDC U1/U2
Un_~ +~
A2 A1 21 22 24
s
Un_~ +~
A2 A1 21 22 24
s
230/115VAC
Time Relays
QZMU• Change-over relay
• Start/Stop function
• 6 Time ranges
© Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10 ZR/37
Terminal Designations
Programming
14 12 34 32
11 31
Operating LED
Range adjustment
Time range selection t1
Time elapse LED
Range Adjustment t2
s
d
Ud-Function: When “s” closes “d” is energised after completionof the time period “t1” and remains energised for the time period“t2”. This cycle repeats itself until “s” opens. When the relay iscontrolled by the power supply the relay is de-energised instan-taneously when “s” opens. If the control is by means of an exter-nal contact the time already started is first completed.
Description
FunctionsUd = Change-over function (beginning with interval)
Time Ranges0,1 – 99,9s1 – 999s0.1 – 99,9m1 – 999m0,1 – 99,9h1 – 999h
Power Supply24-48VAC/DC
115VAC (Transformer)230VAC (Transformer)
U1 (12- 72VAC/DC)U2 (80-240VAC/DC)
Control MethodsPower supply
Function
Range adjustment t1
Time range selection t2
t1 t2 t1 t2
Output terminal
®
ZR/38 © Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10
QZ
MU
- 6
.E -
10G
Technical Data
Timing CharacteristicsTime adjustmen digitalAdjustability ±1 digitRepeat accuracy ±0,01% or 10msTemperature stability ±0,001%/°C ± 10msVoltage stability ±0,01% or 10ms
Voltage CharacteristicsVoltage variation<100V ±20%>100V –20%/+10%Frequency 50/60HzGalvanic isolation >100V, U1,U2
ControlRecovery time >60ms Resetting time >50msMin.activating time >40msCable impedance <100 Ohm
OutputType Relay 2 C/O Load capacity 250VAC; 6A ohmicDisplay LED yellow
OperationDisplay LED greenOperating temperature –20°C to +60°CStorage temperature –20°C to +80°CPower consumption max. 4VA
Order Information
Control Methods
QZMU 24-48ACDCQZMU 115ACQZMU 230ACQZMU-U1QZMU-U2
Un
s
A2 A1 21 22 24
Controlled by power supply for function Ud
Controlled by potential-free contact for Start/Stop function(In order to use the start/stop function the wire bridge in the lower part of the relay must be interrupted).
Standard Start/Stop
trennencouperinterruptstaccare
© Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10 ZR/17
Description
FunctionsA = On-delayB = Off-delayD = Interval delayFh = Flashing (pulse starting)Fd = Flashing (pause starting)
Time Ranges0,1 – 1s1 – 10s10 – 100s10 – 10m10 – 100m1 – 10h
Control MethodsPower supplyPotential-free contact
Function
Time Relays
TRAB• 5 Programmable functions
• 6 Time ranges
®
Power Supply24–48VACDC
115VAC230VAC
T230VAC (Transformer)
T115VAC (Transformer)
U1 (12- 72VAC/DC)U2 (80-240VAC/DC)
sd
t
sd
t
B-Function: When “s” closes “d” is ener-gised instantaneously and when “s’ opensis de-energised after completion of the time period “t”.
sd
t
sd
t t t t
D-Function: When “s” closes “d” is ener-gised instantaneously and is de-energised after completion of the time period “t”
sd
Fd-Function: When “s” closes “d” is ener-gised after completion of the time period “t”and remains energised for the time period“t”. This cycle repeats itself until “s” opens.
Fh-Function: When “s” closes “d” is ener-gised instantaneously and is de-energisedafter completion of the time period “t” and remains de-energised for the time period “t”.This cycle repeats itself until “s” opens.
t t t t t
Terminal Designations
Programming
14 12 34 32
11 31
A-Function: When “s” closes “d” is ener-gised after completion of the time period “t”and is de-energised instantaneously when“s” opens.
Operating LED
Adjustment range
Time range
Function selectorswitch
Output terminal
ZR/18 © Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10
TR
AB
- 6
.E -
09G
Technical Data
Timing CharacteristicsRange accuracy +10%Time adjustment analogue Adjustability linear Repeat accuracy ±0,2% oder 10msTemperature stability ±0,02%/°C ± 10msVoltage stability ±0,2% oder 20ms
Voltage CharacteristicsVoltage variation<100V ±20%>100V –20%/+10%Frequency 50/60HzGalvanic isolation with Transformer, U1, U2
ControlRecovery time >60ms Resetting time >50msMin. activating time >40msCable impedance <100 Ohm
OutputRelay type 2 C/OLoad capacity 250VAC; 6A ohmicDisplay LED yellow
OperationDisplay LED greenOperating temperature –20°C to +60°CStorage temperature –20°C to +80°CPower consumption max. 4VA
Order Information
Control Methods
TRAB 24-48ACDCTRAB 115ACTRAB 230ACTRAB T230ACTRAB T115ACTRAB-U1TRAB-U2
Un
s
A2 A1 21 22 24
Controlled by power supply for functions A,D,Fh,Fd
Uns
A2 A1 21 22 24
Controlled by potential-free contact for function B
®
© Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10 ZR/11
Time Relays
TWMAB• 3 Programmable functions
• Fixed time 0.4s
sd
t
D-Function: When “s” closes “d” is energi-sed instantaneously and is de-energised af-ter completion of the time period “t”
sd
t
C-Function: When “s” opens “d” is energi-sed instantaneously and is de-energised af-ter completion of the time period “t”
sd
t1 t2
CD-Function: When “s” closes “d” is ener-gised instantaneously and is de-energisedafter completion of the time period “t1”.When “s” opens “d” is again energised instantaneously and is de-energised aftercompletion of the time period “t2”. (Relay with time “t1”=”t2”)
Terminal Designations
Programming
14 12 34 32
11 31
Operating LED
Output terminal
Function selectorswitch
Description
FunctionsC=Breaking-pulseD=Instantaneous delayCD=Making-pulse/Breaking-pulse
Time0.4s fixed time
Power Supply24-48 VAC/DC
115 VAC (Transformer)230 VAC (Transformer)
U1 (12- 72 VAC/DC)U2 (80-240 VAC/DC)
Control MethodsPower supply
Functions
ZR/12 © Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10
TW
MA
B -
6.E
- 0
9G
Technical Data
Timing CharacteristicsRepeat accuracy 10msTemperature stability 15msVoltage stability 10ms
Voltage CharacteristicsVoltage variation<100V ±20% >100V –20%/+10%Frequency 50/60HzGalvanic isolation >100V, U1, U2
ControlResetting time >60ms Min. activating time >60ms
OutputRelay type 2UK Load capacity 250VAC; 6A ohmicDisplay LED yellow
OperationDisplay LED greenOperating temperature –20°C to +60°C Storage temperature –20°C to +80°CPower consumption max. max. 4VA
Order Information
Control Methods
TWMAB 24-48ACDCTWMAB 115ACTWMAB 230ACTWMAB-U1TWMAB-U2
Un
s
A2 A1 21 22 24
Controlled by power supply with Functions C,D,CD
®
Technische Information
© Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10 ZR/13
Description
FunctionB = Off-delay (voltage-free)
Time Ranges0.1 – 1s0.5 – 5s3 – 30s10 – 100s1 – 10m3 – 30m
Power Supply24 VAC/DC
36-48 VAC/DC115 VAC (Transformer)230 VAC (Transformer)
U1 (12- 72 VAC/DC)U2 (80-240 VAC/DC)
Control MethodsPower supply
Function
TZMBh• Off-delay (voltage-free)
• 6 Time ranges
• Linear time adjustment
• External potentiometer
Terminal Designations
Programming
14 12 34 32
11 31
Operating LED
Range adjustment
Time range selection
s
d
t
B-Function: When “s” closes “d” is energised instantaneouslyand when “s’ opens is de-energised after completion of the time period “t”.
Output terminal
ZR/14 © Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10
TZ
MB
h -
6.E
- 0
9G
Technical Data
Timing CharacteristicsRange accuracy +10%Time adjustment analogueAdjustability linear Repeat accuracy ±0.5% or 10msTemperature stability ±0,1% ± 10ms/°CVoltage stability ±0,5% or 10ms
Voltage CharacteristicsVoltage variation<100V ±20% >100V –20%/+10%Frequency 50/60HzGalvanic isolation >100V, U1, U2
ControlRecovery time 0,3s, Time range >1m = 2sMin. activating time 0,3s, Time range >1m = 2s Cable impedance <100 Ohm(Potex connection)
OutputRelay type 2 C/O Load capacity 250VAC; 6A ohmicDisplay LED yellow (extinguished
when voltage is removed)Operation
Display LED greenOperating temperature –20°C to +60°CStorage temperature –20°C to +80°CPower consumption max. 4VA
Order Information
Control Methods
Un
s
TZMBh 24ACDCTZMBh 36-48ACDCTZMBh 115ACTZMBh 230ACTZMBh-U1TZMBh-U2
A2 A1 21 22 24
Controlled by power supply
POTIN POTEX
Potex Connection(When the Potex connection is used the wire bridge in the lowerpart of the relay must be interrupted and the internal potentio-meter set to 0.1 (minimum)).The external potentiometer must have a resistance of 100 kOhm.
trennencouperinterruptstaccare 21 22 24
Ø
Description
FunctionsAB = On-delay/Off-delayU1Z = Change-over function (1 cycle)Ud = Change-over function (pulse starting)
Time Ranges0,1 – 1s1 – 10s10 – 100s1 – 10m10 – 100m1 – 10h
Control MethodsPower supplyPotential-free contact
Function
Time Relays
TZMK• 3 Programmable functions
• Stop or Reset function
• 6 Time ranges for t1
• 6 Time ranges for t2
© Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10 ZR/29
sd
t1 t2
U1Z-Funktion: When “s” closes “d” is ener-gised after completion of the time period“t1” and is de-energised after completion of the time period “t2”. If “s” is actuated afterthe time has started it has no effect on thefunction.If the control is by means of an externalcontact the time already started is comple-ted when “s” opens.
sd
t1 t2
AB-Funktion: When “s” closes “d” is ener-gised after completion of the time period“t1” and when “s” closes it is de-energised after completion of the time period “t2”.(Relay with time “t1”=”t2”)
sd
Ud-Funktion: When “s” closes “d” is ener-gised after completion of the time period“t1” and remains energised for the time period “t2”. This cycle repeats itself until “s”opens. When the relay is controlled by the powersupply the relay is de-energised instantane-ously when “s” opens. If the control is by means of an external contact the time already started is first completed.
Terminal Designations
Programming
14 12 34 32
11 31
Operating LED
Control mode andStop/Reset switch
Function selectorswitch
Range adjustment t1
Time range selection t1
Range adjustment t2
Time range selection t2
Stop/Reset
t1 t1t2 t2
Power Supply24-48VAC/DC
115VAC (Transformer)230VAC (Transformer)
U1 (12- 72VAC/DC)U2 (80-240VAC/DC)
Output terminal
®
ZR/30 © Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10
TZ
MK
- 6
.E -
09G
Technical Data
Timing CharacteristicsRange accuracy +10%Time adjustment analogueAdjustability linear Repeat accuracy ±0,2% or 10msTemperature stability ±0,02%/°C ± 10msVoltage stability ±0,2% or 20ms
Voltage CharacteristicsVoltage variation <100V ±20%>100V –20%/+10%Frequency 50/60HzGalvanic isolation >100V and U1/U2
ControlRecovery time >60ms Resetting time >50msMin. activating time >40msCable impedance <100 Ohm
OutputType Relay 2 C/OLoad capacity 250VAC; 6A ohmicDisplay LED yellow
OperationDisplay LED greenOperating temperature –20°C to +60°CStorage temperature –20°C to +80°CPower consumption max. 4VA
Order Information
Control Methods
TZMK 24-48ACDCTZMK 115ACTZMK 230ACTZMK 240ACTZMK-U1TZMK-U2
A2 A1 21 22 24
Un s
Controlled by power supply forfunctions U1Z, Ud
A2 A1 21 22 24
Uns
Controlled by potential-freecontact for functions AB, U1Z,Ud
A2 A1 21 22 24
Uns
Controlled by potential-freecontact for functions AB, U1Z,Ud
© Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10 ZR/27
Description
FunktionenA = On-delayB = Off-delayD = Interval delayFh = Flashing (pulse starting)Fd = Flashing (pause starting)C = Breaking-pulse
Time Ranges0,1 – 1s1 – 10s10 – 100s1 – 10m10 – 100m1 – 10h
Control MethodsPower supply Voltage controlled Potential-free contact
Function
Time Relays
TZMP• 6 Programmable functions
• 6 Time ranges
• Linear time adjustment
Power Supply24–48VAC/DC
115VAC (Transformer)
230VAC (Transformer)
U1 (12- 72VAC/DC)U2 (80-240VAC/DC)
Terminal Designations
Programming
14 12 34 32
11 31
Operating LED
Range adjustment
Time range selection
Function selectorswitch
Output terminal
sd
t
sd
t
sd
t
sd
t t t t
D-Function: When “s” closes “d” is ener-gised instantaneously and is de-energisedafter completion of the time period “t”
sd
sd
t
Fd-Function: When “s” closes “d” is ener-gised after completion of the time period “t”and remains energised for the time period“t”. This cycle repeats itself until “s” opens.
C-Function: When “s” opens “d” is ener-gised instantaneously and is de-energisedafter completion of the time period “t”
Fh-Function: When “s” closes “d” is ener-gised instantaneously and is de-energisedafter completion of the time period “t” and remains de- energised for the time period“t”. This cycle repeats itself until “s” opens
t t t t t
A-Function: When “s” closes “d” is ener-gised after completion of the time period “t”and is de-energised instantaneously when“s” opens.
B-Function: When “s” closes “d” is energi-sed instantaneously and when “s’ opens isde-energised after completion of the time period “t”
®
ZR/28 © Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10
TZ
MP
- 6
.E -
09G
Technical Data
Timing CharacteristicsRange accuracy +10%Time adjustment analogue Adjustability linear Repeat accuracy ±0,2% or 10msTemperature stability ±0,02%/°C ±10msVoltage stability ±0,2% or 20ms
Voltage CharacteristicsVoltage variation<100V ±20% >100V –20%/+10%Frequency 50/60HzGalvanic isolation >100V and U1/U2
ControlRecovery time >60ms Resetting time >50msMin. activating time >40msCable impedance <100 Ohm
OutputType Relay 2 C/O Load capacity 250VAC; 6A ohmicDisplay LED yellow
OperationDisplay LED greenOperating temperature –20°C to +60°CStorage temperature –20°C to +80°CPower consumption max. 4VA
Order Information
Control Methods
A2 A1 21 22 24
Un s
A2 A1 21 22 24
Uns
A2 A1 21 22 24
Un s NP
N
~ ~
Controlled by power supply forfunctions A, D, Fh, Fd
Controlled by voltage for functions B, C
Controlled by voltage forfunctions B, C
Voltage controlled24-48VACDC
230/115VAC
U1/U2
Controlled by potential-freecontact for functions B, CSemi-conductor (proximityswitch with 3 leads)
Controlled by voltage for functions B, C
TZMP 24-48ACDCTZMP 115ACTZMP 230ACTZMP 240ACTZMP-U1TZMP-U2
Un_~ +~
A2 A1 21 22 24
s
Un_~ +~
A2 A1 21 22 24
s
© Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10 ZR/15
Description
FunctionS = Star-delta
Time Ranges0.1 – 1s1 – 10s10 – 100s1 – 10m10 – 100m1 – 10h
Star to DeltaFixed change-over time of 200 ms
Power Supply24 VAC/DC115 VAC (Transformer)230 VAC (Transformer)
Control MethodsPower supply
Function
Time Relays
TZMS• Star-delta Function
• 6 Time ranges
Terminal Designations
Programming
14 12 34 32
11 31
Operating LED
Range adjustment
Time range selection
S-Function: When “s” closes “d1” is energised after completionof the time period “t”. “tF” then starts and on completion “d2” is energised. Both contacts are de-energised instantaneouslywhen “s” opens.
s
d1
d2
t tF
Output terminal
®
ZR/16 © Bircher AG SafeTec® CH-8222 Beringen Phone ++41(0)52-687 11 11 Fax++41(0)52-687 12 10
TZ
MS
- 6
.E -
09G
Technical Data
Timing CharacteristicsRange accuracy +10%Time adjustment analogue Adjustability linear Repeat accuracy ±0,2% or 10msTemperature stability ±0,02%/°C ± 10msVoltage stability ±0,2% oder 20ms
Voltage CharacteristicsVoltage variation<100V ±20% >100V –20%/+10%Frequency 50/60HzGalvanic isolation >100V
ControlRecovery time >60ms Resetting time >50msCable impedance <100 Ohm (Potex connection)
OutputType 2 relays each C/O Load capacity 250VAC; 6A ohmicDisplay LED yellow
OperationDisplay LED greenOperating temperature –20°C to +60°C Storage temperature –20°C to +80°CPower consumption max. 4VA
Order Information
Control Methods
Un
s
TZMS 24-48ACDCTZMS 115ACTZMS 230AC
A2 A1 21 22 24
Controlled by power supply
POTIN POTEX
Potex Connection(When the Potex connection is used the wire bridge in the lowerpart of the relay must be interrupted and the internal potentio-meter set to 0.1 (minimum)).The external potentiometer must have a resistance of 100 kOhm.
trennencouperinterruptstaccare 21 22 24
Ø
Industrial Safety SalesI N C O R P O R A T E D
INDUSTRIAL SAFETY SALES INC.
P.O. Box 126 -- 4112 Sheridan Road Kenosha, WI 53141Fax: (262) 652-1388 E-mail: [email protected]
(262) 652-8660