Page 1: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE& MATERNITY

INFA

NT

CA

RE

& M

AT

ER

NIT

YC

Page 2: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 126

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Page Description

127 Atom Incubators & Warmers

Dual Incu i Hybrid Incubator/Warmer

128 Incu i Incubator

129 Air Incu i Incubator

130 InfaWarmer i

131-134 Incubator/Warmer Optional Accessories

Atom Power Pack i

Weight Monitor

132 Incu i Tester

InfaLite

134 Incubator/Warmer Add-on Accessories

135-136 Sunflower Resuscitation Warmers

137 - 138 Sunflower Optional Accessories

139 Neo Cot Bassinette (Hi/Low)

140 Resusciflow Resuscitation Unit

141 Atom Phototherapy Devices

BILI-Therapy Spot Type

142 BILI-Therapy Pad Type

143 - 144 V-808 Infant Transport Incubator

145 Atom Incubator and Warmer Peripheral Accessories

146 Atom Microfilters for Incubators

147 S-1235 Syringe Pump

148 Neonatal Phototherapy Unit

149 Neonatal Mattress and Blanket Warming Systems

150 Infant Care Products Monitoring Systems

Babycontrol® Apnoea Monitor

Newborn Transcutaneous Jaundice Meter

151 Infant Care Products

NeoGuard 3000 Neonatal Resuscitator

152 - 155 Infant Resuscitation Circuit with PEEP Controller

154 i-Puff All In One Disposable Infant Resuscitation Circuit

156 - 158 IV Armboards - Neonate to Adult

Neonatal SpO2 Cover / Securing Strap

Umbilical Clamps

Umbilical Clamp Cutters

159 Neoshades® - Phototherapy Eyeshades

Neoshades® with Headstrap - Phototherapy Eyeshades

160 Snorkel Suction Device

Suction Caddy™ - Device Holder for Little Sucker®

Page Description

160 Infant Care Products (cont.) Meconium Aspirator® - Meconium Removal Device

Neoseal - CPAP Nasal Prong Seal

161 Neobar® - ET Tube Holder

NeoLead® - Pre-wired Neonatal Electrodes

162 Micro Neolead® - Pre-wired Neonatal Electrodes

Mini Neolead® - Pre-wired Neonatal Electrodes

NeoGrip™ - Multi-purpose Tubing and Cable Holders

163 Hold-A-Line™ - Catheter and Tubing Holder

NeoBridge® - Umbilical Catheter Holder

EZ-Hold® - Tubing and Cannula Holder

164 NeoBond® - Medical Grade Hydrocolloid Strips

Neosmile™ - Temperature Probe Cover

Neotech Chinstrap - Soft, comfortable Chin strap

165-166 NeoPulse™ - Disposable Pulse Oximeter Wrap

Neospoon™ - Measuring Spoon

Duotube Silicone Binasal Pharangeal Airways

EZCare™ - Tracheostomy Tube Holder

EZCare Softouch™ - Dispo. Tracheostomy Tube Holder

167 Little Sucker® - Oral/Nasal Suction Devices

Little Sucker® Covers

RAM Cannula™ - CPAP Nasal Cannula

168 Bidibots - Neonatal Nappies

169 Disposable & Reusable SpO2 Sensors

Masimo

Nellcor

Comepa Neonatal Electrodes

Silicone Nipple Shields

Test Lung - Atom

170 Infant Nasal CPAP

CPAP Kits

171 CPAP Adaptors

10mm ID Plastic Tubing

172 Infant Stethoscopes

173 Equinox Advantage Self Administered Analgesic Unit

174 Gas Evac Nitrous Oxide Scavenge Device

175 - 177 Analgesic / Mid-O-Gas Circuits

178 Obstetric Dopplers

179 Vascular Dopplers

180 Homecare Obstetric Dopplers

Ultrasound Transmission Gel

Contents

Page 3: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 127

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

YIN

FAN

TC

AR

E&

MA

TE

RN

ITY

Dual Incu Hybrid Warmer/Incubator Model: 100

Standard Features:

Easy to Read Multi-function Display Touch Screen Control Panel Servo Humidity Controller with Removable Chamber Oxygen Controller Single Switch Operation to Change from Incubator to Warmer Mode Pre-heating Function Mattress Platform with Smooth Continuous Tilt Hands-free Door Latches Electrostatic Filter System visible from outside the Incubator

Air Curtain to Minimise drop in Incubator Air Temperature Hi/Low Stand F-Rail for Various Mounting Options Rotary Damper to Ensure Smooth Fold-down Doors Double-lock Front Admittance Panel Compatible with Philips Monitors Pressure Dispersion Mattress Single Knob for Tilting Mattress External Access X-Ray Cassette from Both Sides of Unit

INCUBATOR MODE

Optional Accessories: 61621 Masimo™ Pulse Oximetry61622 Nellcor™ Pulse Oximetry61619 Weight Monitoring61581 UPS Power Supply60888 Dual Side Access Drawer23718 Cylinder Holders for Transportation60893 IV Pole

Main Unit: 61601 Dual Incu Incubator with Oxygen Controller

Page 4: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 128

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Incu Incubator Model: 101

Standard Features:

Easy to Read Multi-function Display Touch Screen Control Panel Servo Humidity Controller with

Removable Chamber Oxygen Controller Mattress Platform with Smooth

Continuous Tilt Hands-free Door Latches Hi/Low Stand

Electrostatic Filter System visible from outside the Incubator

External Access X-Ray Cassette from Both Sides of Unit

Quiet Environment for Baby - Sound levels do not exceed 45 dB

Air Curtains - to minimise Drop in Incubator Temperature

F-Rail for Various Mounting Options

Rotary Damper to Ensure Smooth

Fold-down Doors

Double-lock Front Admittance Panel

Pressure Dispersion Mattress

Single Knob for Tilting Mattress

Twin Castors for Easy Manoeuvering

Capability with Philips Monitors

(via plug connection on rear of LCD)

Optional Accessories: 61621 Masimo™ Pulse Oximetry61622 Nellcor™ Pulse Oximetry61615 Weight Monitoring61581 UPS Power Supply60888 Dual Side Access Drawer60893 IV Pole

Main Unit: 61606 Incu Incubator with Oxygen Controller

Page 5: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 129

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Air Incu Incubator Model: 62062

INFA

NT

CA

RE

&M

AT

ER

NIT

Y

Standard Features:

Air Curtain designed to minimise temperature loss when a snap-open access port is opened

Humidity Control allowing upto 95% relative humidity to be produced meeting humidification requirements for even the smallest neonates.

Noise level lower than 45db reducing stress to neonates

Night Mode reducing light stimulation in neonates

Antimicrobial panel screen Optional Oxygen Controller Unit, Weight

Monitor Unit and Sp02 Unit (Masimo/ Nellcor)

Easy cleaning, disinfection and

maintenance through modular design

The hood can be disassembled without any tools being required. Broken or damaged parts in the hood can be easily individual replaced reducing maintenace costs.

Jointless hood minimises chance that surfaces are unwiped/uncleaned and provides good visability of the inside of the incubator.

High Scalability through extension options and add-ons tailored to the caregivers needs.

Optional Accessories: 61621 Masimo™ Pulse Oximetry61622 Nellcor™ Pulse Oximetry62071 Weight Monitoring Unit62070 O2 Controller Unit62086 Drawer with mounting bracket for HL Stand62087 IV Pole for HL Stand62088 IV Pole for Cabinet Stand

Main Unit: 62062/FS Air Incu Incubator with Fixed Stand62062/HLS Air Incu Incubator with Hi-Low Stand

Page 6: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 130

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Infa Warmer Model: 103

Standard Features:

Pre-heating Function

Far-infrared Radiation

CPR/APGAR Timer

Adjustable LED Light

“Smooth” Fold-out Baby Guards

X-Ray Tray

Hi/Low Pedals at Both Sides of Warmer

Swivel/Tiltable Heater

Twin Castors - for Easy Manoeuvering

F-Rail for Various Mounting Options

Pressure Dispersion Mattress

ards

s of Warmer

oeuvering

Options

ss

Optional Accessories:

61625 Masimo™ Pulse Oximetry 60988 Dual Side Access Drawer

61626 Nellcor™ Pulse Oximetry 61581 UPS Power Supply

61647 Baby Scales with Display 23718/3 Cylinder Holders - for Transportation

60893 IV Pole

61651 Integrated Resuscitation Unit 104 Including: Infant Resuscitation Device, Blender, Suction & Flowmeter

61653 Integrated Resuscitation Unit 105 Including: Blender, Suction &Flowmeter

Main Unit: 61634 Infa Warmer

Page 7: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 131

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Atom Power Pack

The Atom Power Pack i (UPS) is an uninterruptible power supply which protects the unit from power failure or power interruption.

61581 Atom Power Pack i

Model

Dual Incu i

& Incu i

Dual Incu i

Infa Warmer i

Operation Mode

Manual control with air temperature of 36°C (in a stable condition) Radiant warmer mode with heater output of 100%

Heater output of 100%

Heater output of 50%

Servo-control mode with skin temperature of 36° C (in a stable condition)

Lithium-Ion

Approx. 150 min

Approx. 30 min

Approx. 30 min

Approx. 60 min Approx. 45 min

Atom Incubator and Warmer Optional Accessories

Weight Monitor Unit

61647 Weight Monitor Unit for F-Rail (Suitable for Infant Warmer i)

Battery Operational Time

Page 8: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 132

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Atom Incubator and Warmer Optional Accessories

Incu Tester

Measures: Temperature, O2 Concentration and Relative Humidity Data measurement can be controlled by your PC / laptop Data can be stored in your personal computer / laptop Comparative evaluation of Temperature, O2 Concentration and

Relative Humidity 5 points of temperature monitoring enables the measurement of

consistent and stable temperature environments Special sensor disk enables measurement of the radiation heat of

the warmer Works with ALL BRANDS of Incubators and Infant Warmers

61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation heat of the Incubator / Warmer

InfaLite

InfaLite with F-Rail Attachment

60216-F InfaLite LED Examination Light for F-Rail Includes: Hand sensor (touch-free) ON-OFF

InfaLite with IV Pole Attachment

60216-P InfaLite LED Examination Light for IV Pole Includes: Hand sensor (touch-free) ON-OFF

Page 9: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 133

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Atom Incubator and Warmer Optional Accessories

60873 F-Rail Pole for Incu i 60893 IV Pole for F-Rail 60892 Crank Type IV Pole for i SeriesIncubators

61581 UPS Power Pack i (Suit Model: 100,101 & 103)

60888 Drawer for i Series Incubators

60988 Drawer for Infa Warmer i 60874 Drainage Hanger (Front) for i Series Incubators

60875 Drainage Hanger (Side) for i Series Incubators 61642 Drainage Hanger for Infa Warmer i

Page 10: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 134

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Atom Incubator and Warmer Optional Accessories

61616 MF-Rail 60350 F-Rail Monitor Table for Philips monitor

60349 F-Rail Monitor Table

60894 Basket with Arm for F-Rail 61617 Tray Set for F-Rail 61618 Tray Set (S) for F-Rail

60879 Pressure Dispersion Mattress for i Series Incubators

61628 Pressure Dispersion Mattress for Infa Warmer i

60896 Mattress for i Series Incubator

60899 Handle for F-Rail (2 pcs./set)

23718 F-Rail Cylinder Rack (per pce.)

23718/3 Triple Cylinder RackSuit: Infa Warmer i

23718/2 Dual Cylinder RackSuit: Infa Warmer i

Page 11: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 135

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Atom Sunflower Resuscitation Warmers

Sunflower Warmer, Hi/Low Tilt

Features:

Hi/Low Stand Apgar Timer CPR Timer Mattress Platform Tilting Rotary Damper (Smooth Fold-down Sides) Double Wheel Castors X-Ray Cassette Tray Port Drawer (Optional - Additional Cost) Built-in LED Lights

61565 Sunflower Warmer, Hi/Low Tilt

Options:

60983 2-Layer Drawer (shown below) 60899 Handles to suit F-Rail (pair)

Refer to following pages for entire list of Optional Accessories.

Sunflower Warmer, Wall Mount

Features:

Apgar Timer CPR Timer Built-in LED Lights

61575 Sunflower Warmer, Wall Mount

Page 12: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 136

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Atom Sunflower Resuscitation Warmers

Sunflower Warmer, Cabinet / Tilt

Features:

Fixed Stand Apgar Timer CPR Timer Mattress Platform Tilting Rotary Damper (Smooth Fold-down Sides) Double Wheel Castors X-Ray Cassette Tray Port Cabinet Built-in LED Lights

61567 Sunflower Warmer, Cabinet / Tilt

Options:

60899 Handles to suit F-Rail (pair)

Refer to following page for entire list of Optional Accessories

Sunflower Mobile Warmer, Stand

Features:

Fixed Stand Apgar Timer CPR Timer Built-in LED Lights

61573 Sunflower Warmer, Stand

Refer to following page for entire list of Optional Accessories

Page 13: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 137

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Optional Accessories:

Atom Sunflower Resuscitation Warmer Accessories

60362 Resusci Flow 60363 Resusci Flow with Blender

60983 2-Layer Drawer 61642 Drainage Hanger

61647 Weight Monitor 60894 Basket 61618 Tray Set (S) 61616 MF-Rail

60984 Shelf 60893 F-Rail IV Pole 60899 F-Rail Handle (Pair) 60350 Monitor Tablefor Philips Monitor

60361 Bili-Therapy Spot Type Arm 60871 Tube Holder 60216-F Infa Lite

Page 14: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 138

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Atom Sunflower Resuscitation Warmer Accessories

Sunflower Resuscitation Warmer Series Accessories:

60983 2-Layer Drawer

60984 Shelf for Sunflower Warmer

61642 Drainage Hangar - Suit: Infa Warmer i / Sunflower

60894 Basket with Arm for F-Rail

S1235 Syringe Pump

61618 Tray Set (S) for F-Rail

60350 Monitor Table (Philips) for F-Rail

61616 MF-Rail for F-Rail (Left & Right)

61647 Weight Monitor - Suit: Infa Warmer i / Sunflower

60363 Resusci Flow with Blender

60361 Bili-Therapy Spot Type (Arm Type)

60893 IV Pole for F-Rail

60216-F InfaLite for F-Rail

60215 Neo-Light for F-Rail

60899 Handle for F-Rail

13

12

8

10

2

4

7

11

9

6

3

1

1

2

3

4

6

7

8

9

10

11

12

13

5

5

Page 15: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 139

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Atom NeoCot Neonatal Portable Bassinette

NeoCot with High/Low Stand

The Neo Cot has been designed to support the caring model of both mothers and nursing staff, paying special attention to safety and interaction.

Features:

Hi/Low Stand (lowest height 62cm) Ability to set height to match eye lines to promote kangaroo care Waterproof Mattress Mattress Platform Tilting Space saving design contributes to space management Four wheel lock with castors that can be unlocked from any direction Variety of peripherals can be attached

26408 NeoCot with High/Low Stand

Options:

26113 IV Pole

26114 Drawer

26117 Basket 26118 Mattress

26122 Mattress Sheet

26123 Shade

26411 Cylinder Rack

26113 IV Pole

26114 Drawer 26411 Cylinder Rack 26118 Mattress

26117 Basket 26122 Mattress Sheet 26123 Shade

Neocot shown with various options addedNeocot shown with various options added

Page 16: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 140

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Atom Resusci Flow Resuscitation Unit

The Atom “Resusci Flow” is a resuscitation unit that performs artificial respiration with a stable pressure. Using the Resusci Flow with the Parker TB2000 Resuscitation Circuit, the user has the ability to control the inspiratory time by placing a finger over the PEEP port located on top of the circuit adjustment valve. The Resusci Flow maintains a preset peak inspiratory pressure (PIP) and positive end-expiratory pressure (PEEP) to a constant pressure. The PEEP of the TB2000 Flow Controller can be adjusted by rotating the flow control knob located on top of the circuit adjustment valve to the desired setting.

60362 Resusci Flow (Rail Mounting Type)

60363 Resusci Flow (with Blender) Rail Mounting Type

Optional Accessories:

60366 CPR Timer

TB2000 Patient Circuit with adjustable PEEP Flow Controller

TB2000-M0 Disposable Patient Circuit with adjustable PEEP Flow Controller and Size 0 Air Cushion Mask

TB2000-M1 Disposable Patient Circuit with adjustable PEEP Flow Controller and Size 1 Air Cushion Mask PH20116 Disposable Size 0 Air Cushion Face Mask

PH20117 Disposable Size 1 Air Cushion Face Mask 60298 Test Bag (50mL)

60368 Resusci Stand with Cylinder Rack (for 2 pcs)

60263 Safety Weight (5kg) for 5-legged stand

60367 MF Rail (26cm) Pole Mounting Type

60306 MF Rail (7cm) Pole Mounting Type

60369 Basket - Rail Mounting Type

61616 MF Rail for F-Rail

518804 Pressure Regulator (O2)

518809 Pressure Regulator (Air)

60362 Resusci Flow Unit

60366 Optional CPR Timer

60363 Resusci Flow Unit with O2/Air Blender, optional

CPR Timer and TB2000 Patient Circuit

Resusci Flow’s Preset Safety Functions

Atom Resusci Flow Resuscitation Unit and Accessories

See page 152 for TB2000 resuscitation circuits

Page 17: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 141

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Bili-therapy (LED Phototherapy Unit) Spot Type

Bili-therapy units promote early hospital discharge by reducing the treatment time in providing high irradiation intensity and effective wavelength from blue LED’s to the patient. The spot unit may be mounted on the F-Rail without using a stand for space-saving around the incubator or warmer.

Effective Phototherapy Treatment by Blue LED’s Switchable to Examination Light (White LED’s) Space-saving design

60361 Bili-Therapy (LED Phototherapy Unit) for F-Rail Spot Type “Arm” Style

60377 Bili-Therapy (LED Phototherapy Unit) Spot Type “Mount” Style

Options for Mounting:

60380 F-Rail Attachment 60381 IV Pole Attachment

60360 Bili-Therapy (LED Phototherapy Unit) Spot Type “Stand” Style

Bili-therapy Spot Type “Arm” and “Stand” Styles

Power requirements: 240V 50/60Hz Power consumption: 30VA

Light source: Blue LEDs

Irradiance level: At least 30-40μW/cm2/nm

(obtained by the BiliBlanket® meter at the irradiation distance of 30cm)

Illumination intensity: Approx. 1000 lux or higher (Distance from light source: 30cm)

Refer to page 159 for phototherapy eyeshades.

Atom Phototherapy

Page 18: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 142

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Atom Bili-therapy Phototherapy

Bili-therapy (LED Phototherapy) Pad Type

The Bili-therapy Pad Type delivers effective phototherapy for the treatment of indirect hyperbilirubinemia. The pad design allows for the unit to apply the treatment from the back of the newborn.

60370/LP Bili-Therapy (Phototherapy Unit) Fibre Type with Large Pad

60370/SP Bili-Therapy (Phototherapy Unit) Fibre Type with Small Pad

Accessories:

60371 Pad (Large Pad)

60372 Pad (Small Pad)

60373 Pad (Large) Cover (50pcs/box)

60374 Pad (Small) Cover (50pcs/box)

60375 Bili-Holder for F-Rail

60376 Bili-Stand

68448 Phototherapy Analyzer II

60371

60372

60373

60374

60375

60376

68448

Bili-therapy Pad Type can be used in a bassinet next to the mother’s bed.

Bili-therapy Pad Type along with Bili-therapy Spot Type can effectively provide double therapy treatment without interfering with visualisation of the newborn.

60371

60372

21

1

2

Rela

tive

Irrad

ianc

e Ra

tio (%

)

Wavelength (nm)

Page 19: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 143

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Atom V-808 Transport Incubator

The Atom V-808 is able to maintain a stable nursing environment in a variety of transport situations, even when the ambient temperature is 0°C and can operate on three different kinds of power source including ambulance car and helicopter. With the SpO2 feature, the skin temperature monitor and oxygen monitor incorporated, the Atom V-808 supports the emergency medical care of neonates with its complete functions and reliability.

Features:

Head-end admittance Front and Rear snap-open access ports Separate main unit for increased mobility Operates from 3 different kinds of power source Double-wall Hood for stable nursing environment Built-in Masimo SET® pulse oximeter Temperature and Oxygen monitor - Standard Equipment The Light and clear 1500-lux lamp Low resilience mattress Electrostatic filter

CM-6633 Atom V-808 Incubator

CM-6633/TROLLEY Hi/Low Trolley (Optional Stainless Steel Hi/Low trolley as pictured opposite)

V808/Trolley Fixed height trolley (800mmH) (suitable for V808 “Incubator only”)

V808/Trolley/A Fixed Height Trolley (620mmH) (suitable for V808 “Incubator and Mount section only”)

V-808 Transport Incubator with Optional Hi/Low Trolley

Masimo SpO2, Temperature Monitor & Oxygen Monitor - Standard Equipment

Head-end Admittance with Front & Rear Access Ports

Light and Clear 1500-lux LampOptional V808/Trolley/Fixed Height Trolley

Page 20: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 144

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Atom V-808 Transport Incubator

THE SEPARABLE MAIN UNIT FOR INCREASED MOBILITY

The main unit, which contains a sub-battery ensuring more than fifteen minutes operation, is separable from the main battery. When separated, the main unit weighing approx. 34kg, is conveniently used to transport the infant easily up and down stairs or through a small space. The stand, equipped with a gas spring, is vertically and smoothly adjustable and can be fixed at any height within the range of 32-61cm.

THREE KINDS OF POWER SOURCE

The V-808 Transport Incubator supports three kinds of power sources depending on different transport settings:1. The AC power source2. The Internal Battery3. The External DC power source (DC 12V / DC24V)Conforming to EMC standards and provided with measures against electromagnetic interference, the V-808 can cope with various transport settings.

BUILT-IN Masimo SET® PULSE OXIMETER

The built-in Masimo SET® pulse oximeter monitors SpO2 accurately by eliminating noise generated by the infant’s movement. Stable monitoring is ensured even when signals are weak due to poor circulation. DOUBLE-WALL HOOD FOR STABLE NURSING ENVIRONMENT

The double-wall hood minimises the infant’s radiant heat loss. In addition, the powerful capability of thermal maintenance and the precise temperature control system maintain the incubator air temp. at 34°C even when the ambient temp. is 0°C.

Optional Accessories and Supplies:

60308* (CM-6635) Mon. Table with fixing belt

(* Must be ordered with V-808 - cannot be attached at a later stage)

60306 MF Rail 7cm (pole mount type)

60307 Multi-purpose Pole (8 kg limit)

60861 Semi-iris Access Port Cover (10 pcs/pkg)

60860 (CM-5793) Access Port Cover (10 pcs/pkg)

60269 Filter Element E (10 pcs/pkg)

60883 (CM-6451Y) Skin Temp. Probe (Preemie)

60882 (CM-6450Y) Skin Temp. Probe (Neonate)

60884 (CM-6452Y) Disposable Skin Temperature Probe

60885 Connecting Cable (Disposable Skin Temperature Probe)

V808/GBA Gas Block Assembly

2

1

3

4

2

1

3

4

Incubator Only

Mount Section Trolley

Separate Main Unit

Page 21: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 145

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Atom Incubator and Warmer Optional Accessories

Peripheral

Consumables

60078 Atom Feeding Syringe Holder 60846 Atom Head Frame 60858 Tube Holder for i Series Incubator

60857 Holder for Patient Circuit with Arm 60871 Tube Holder (for Infa Warmer i / V-505)

60860 Iris Sleeve/Access Port Cover (pkt. 10)

60335 Access Port Frame Set (Iris Type) 60897 Snap-Open Access Port 4103 RD Set MD20 - 5ft

4104 RD Set M0 12ft

2055 LNCS Cable 20 pin 4 ft

2056 LCNS Cable 20 pin 10 ft

CM6451Y Reusable Skin Temp Probe NF.023 Disposable Skin Temp Probe (Packet of 20)

R22 Oxygen Sensor (each)Suit: Atom V-2100G, V-2200 &

V-808

PSR-11-917-MH3 Oxygen Sensor (ea) Suit: Atom Incu i & Dual Incu i

DISPOSABLE See page 164 for temperatureprobe cover.

Page 22: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 146

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Atom Infant Incubator Microfilters

Incubator filters protect the infant from airborne bacteria and other impurities which otherwise would be drawn into the incubator with the ambient air. On inspecting the filter (weekly, when incubators are cleaned, or an infant discharged) it becomes apparent how much debris is captured - even in a spotless NICU.The Microfilter core (Bacterial Filtration Efficiency > 99%) is fully sealed in a water repellent, hypoallergenic membrane. This locks-in all loose fibres, but is permeable to air & oxygen.All Atom Microfilters are clearly labelled for easy identification.

60317 Filter Elements Fits: Atom V-80TR & V-808 (pkt. 5)

60332 F4E Atom Microfilter Fits: Atom V-80, V-850 and V-85 prior to year 2000. (pkt. 5)

60322 F6E Atom Microfilter Fits: Atom V-2200, V-2100G and V-85 after year 2000 (pkt. 5)

60269 Pneumoclean Electrostatic Filter Fits: Atom V-707, Incu i, Rabee Incu i & Dual Incu i (pkt. 5)

60317 Atom Microfilter

60332 F-4E Atom Microfilter

60322 F-6E Atom Microfilter

60269 Electroststic Filter

PRODUCT FILTER O2 SENSOR

Dual Incu i 60269 PSR-11-917-MH3 (pkt. 5) (x 2)

Incu i 60269 PSR-11-917-MH3 (pkt. 5) (x 2)

Rabee 60269 NONE (pkt. 5) REQUIRED

V2100/2200/V85 60322 R22 after year 2000 (pkt. 5) (x 2)

V-80/V850/V-85 60332 NONE Prior to 2000 (pkt. 5) REQUIRED

V-707 60269 NONE Transport (pkt. 5) REQUIRED

V-808/V-80TR 60317 R22Transport (pkt. 5) (x 1)

Page 23: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 147

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Syringe Pump

Atom S1235 Syringe Pump

Especially effective in administering potent medicine more accurately or in micro-infusion where any additional water should be avoided.The Atom 1235 provides a wide range of infusion between 0.1 and 999.9ml/hr with a mechanical accuracy of ±1%.

Features:

4 different sensors monitor the syringe for proper placement Trend graph display of occlusion pressure Features to prevent improper operation Lithium Ion battery Compatible with Diprivan® PFS 1%

S1235 Atom Syringe Pump

OPTIONS & SUPPLIES:

33131 Lithium Ion Battery for S1235

33130 Quick Battery Charger for 2 batteries

Time required for charging battery: Approx. 120 mins.

33125 Tiltable Mounting Table for S1235

33040 Stand for Syringe Pump

32048 Tray Set with tray mount & pole mounting

33044 Safety Weight for a five-legged base

approx. 5 kg. (This weight is attached to the base in order to

make the stand for the syringe pump more stable)

S1235 Syringe Pump

S1235 Pump with CM5781Stand & Tray Set

Quick Battery Charger

2

1

3

4

2

1

3

4

5

6

5

6

Page 24: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 148

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Neonatal Phototherapy Unit

The device is ideal for use in newborn and premature services of hospitals and maternity wards.

Light Intensity Meter

White Examination Lamps

Can be used with incubators, open bed and bassinets

Designed with Power LED technology

Equal patient distribution of light intensity with LED lenses

Regular and Intensive treatment options

Light intensity can be adjusted according to requirements

Does NOT emit Infrared or ultraviolet light

Can be directly placed on incubator

LCD screen

Red focus light for centralising the light on the baby

Telescopic height adjustable control stand with lockable wheels

Auto shut off

Optional monitored skin temperature measurement

KMF-01 Neonate Phototherapy Unit with Adjustable Control Stand

KMF-01SP Neonate Phototherapy Unit with Adjustable Control Stand and temperature probe port and skin probe.

SP-1000 Replacement Skin Probe

SPECIFICATIONS:

Lamp Type: 34 piece Blue Power LED

Lamp Life: 20,000 hours

Light Intensity: >100μw/cm2/nm

Wavelength: 450-470nm

Effectine Surface Area: 50cm x 30cm

Noise Level: <50dBA

Width: 200mm

Length: 350mm

Height: 90mm

Weight: Base Unit = 1.8kg

Mobile Stand = 15kg

Mobile Stand Height Adjustment: 135cm - 165cm

Neonatal Phototherapy

Refer page 159 for phototherapy eyeshades and page 164 for temperature probe covers.

AVAILABLE WITH SUCTION CUP FEET FOR STABLE MOUNTING ON TOP OF INCUBATOR

CANOPY

Page 25: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 149

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Neonatal Mattress & Blanket Warming Systems

CONTROL UNITS

PART NUMBER SIZE DESCRIPTIONW-150T/S 18.7 x 16.8 x 8.7cm With BatteryW-150T/S/TP 18.7 x 16.8 x 8.7cm With Battery, temperature probe port and skin probe

WARMING MATTRESSES

PART NUMBER SIZE TYPE

IM-50M 50 x 35 x 1cm (with foam) Neonatal

IM-60MS 60 x 35 x 2cm (with foam) Neonatal

BLANKETS

PART NUMBER SIZE TYPEIM-40BK 40 x 40cm NeonatalIM-55BK 55 x 50cm Medium (0-6 months)IM-65BK 65 x 70cm Large ( > 6 months)

Extension Cable Length: 2.5mtPad cable Length: 1.0mt

BLANKET COVERS

PART NUMBER DESCRIPTIONIM-50 MDC Disposable cover for premature warming mattress (PKT/10)IM-50 MRC Reusable cover for premature warming mattressIM-55 BKDC Disposable cover for swaddling blanket for premature (PKT/10)IM-65 BKDC Disposable cover for swaddling blanket (PKT/10)IM-65 BKRC Reusable Cover for swaddling blanket

POWER

Control Units - Power input: 220V AC - 110V AC 50Hz / 60Hz

PART NUMBERW-150T/S 90W 24V DC (for Neonatal patient)W-150T/S/TP 90W 24V DC (for Neonatal patient)

SPARES

PART NUMBERSP-1000 Replacement Skin Probe

ALARMS

Power Alarm: Activated if power is cut off or if power cord is disconnected when the unit is turned on.

Pad Alarm: Activated when the connection between the controller and the mattressis cut off.

High Temperature Alarm: High temperature Alarm is sounded once the temperature goes over the system limit of 42°C.

High Deviation Alarm: If the temperature goes +1.5C over the set temperature, high deviation alarm is sounded.

Neonatal Mattress & Blanket Warming Systems

Control Unit

Page 26: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 150

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Apnoea and Jaundice Monitors

Transcutaneous Jaundice Meter

Hyperbilirubinemia is a common condition in newborn infants and may cause kernicterus if not properly managed. Therefore, jaundice in the newborn should be dynamically observed so as to diagnose and treat as quickly as possible. However, repeated blood sampling for measuring serum bilirubin is painful and is a cause for distress to the infant, increases the workload of the nursery staff and is not readily accepted by parents.

KJ-8000 transcutaneous jaundice meter utilizes fiber, photoelectric, electronic and information processing technologies and is small and light. By pressing the probe gently to the forehead of the baby, the bilirubin concentration in the skin tissue is immediately displayed on the LCD screen.

KJ-8000 transcutaneous jaundice meter is designed to be used in newborn nursery, newborn outpatient clinics, newborn intensive care units (NICU), children healthcare department and many more nursery areas.

KJ-8000 Transcutaneous Jaundice Meter

SISS BABYCONTROL®

The SISS BABYCONTROL® monitors the respiration function of babies and infants

and can thus provide reliable assistance against "cot death". High reliability, simple operation and convenient size make the SISS BABYCONTROL

® monitor a universally applicable instrument for baby-monitoring in hospitals, at home or while traveling in a car or baby carriage.

Simple Operation Intelligent Memory Function Mobile Handheld Monitor

PHB00112 Babycontrol Monitor

SISS BABYCONTROL® M

Despite its small size the SISS BABYCONTROL®

M measures and stores complex procedures automatically. The MicroSD memory card can be easily removed fromthe device. To evaluate the stored data with the help of functional software it can be uploaded on a PC.

Masimo Technology Handheld Monitor Easily Removable MicroSD memory Card Mobile Easy to Read LCD

PHB00300 Babycontrol Monitor with Masimo

PHB00112

PHB00300

Page 27: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 151

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Infant Care Products - Resuscitation Unit and Circuits

Legend: M = Male (External) F = Female (Internal) (D) = Disposable ID = Inside Diameter (PP) = Polypropylene (PE) = Polyethylene (PC) = Polycarbonate (S) = Silicone

NeoGuard 3000 Neonatal Resuscitator

Infant T-Piece resuscitator with adjustable peak inspiratory pressure and pressure relief valve.

Accurate Pressure Control Pressure Blow Off Valve Medical Grade Manometer Peak Inspiratory Pressure (PIP) Ergonomic Design Optional Circuits available

NeoGuard 3000 Neonatal Resuscitator NeoGuard 3000A Neonatal Resuscitator with Optional O2 Analyser Port

Optional Oxygen Analyser:

R217P62-004 Oxygen Analyser See page 112 for related product

NeoGuard 3000A with Analyser Port featuring Optional Oxygen Analyser

R217P62-004

NeoGuard 3000A with Optional Analyser Port & O

2 Analyser

NeoGuard 3000A with Analyser Portfeaturing Optional Oxygen Analyser

R217P62-004

Infant Care Products - Resuscitation Unit and Circ

Page 28: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 152

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

HOW THE PEEP FLOW CONTROLLER WORKS:

Adjustable PEEP Flow Controller Function

on Infant Resuscitation Circuits

The Adjustable PEEP Function available on TB Series circuits is a simple device and easily operated by a medical professional, with the added benefit of Double Swivel connections at Mask and Tubing ends.

The top (Green) controller rotates to decrease or increase (±) PEEP pressure.The PEEP port on top of the Green controller (if occluded) instigates PEEP.The PEEP control Indexer offers a physical "click" feedback when rotating.Both adaptor tube and mask connections offer double swivel connections.

DecreasePEEP

22mm M/15mm FSwivel

10mm MSwivel PEEP Port

PEEP FlowController

PEEP Control Indexer

Disposable Infant T-Piece Resuscitation Circuit

with Adjustable PEEP Flow Controller Function

Fits most Infant T-Piece Resuscitators (15mmM/10mmF connector)

Easy to Use

Adjustable PEEP Flow Controller

Double-swivel at Mask and Tubing Ends

PEEP Controller Indexer

TB2000 Disposable Infant T-Piece Resuscitation Circuit with Double Swivel and Adjustable PEEP Flow Controller Function (PP) (PE) (PC)

TB2000A Disposable Infant T-Piece Resuscitation Circuit without Swivel and Adjustable PEEP Flow Controller Function (PP) (PE) (PC)

TB2000-RM0 Disposable Infant T-Piece Resuscitation Circuit with Adjustable PEEP Flow Controller Function and Size 0 Silicone Donut Mask (S)

TB2000-RM1 Disposable Infant T-Piece Resuscitation Circuit with Adjustable PEEP Flow Controller Function and Size 1 Silicone Donut Mask (S)

TB2000-RM2 Disposable Infant T-Piece Resuscitation Circuit with Adjustable PEEP Flow Controller Function and Size 2 Silicone Donut Mask (S)

Size 0 Mask Size 1 Mask

Masks Supplied with TB2000-RM* Circuits

Size 2 Mask

Legend: M = Male (External) F = Female (Internal) (D) = Disposable ID = Inside Diameter (PP) = Polypropylene (PE) = Polyethylene (PC) = Polycarbonate

IncreasePEEP

PEEP Flow Controller

Infant Care Products - Resuscitation Circuits

Size 2 Mask

15mm M

/10mm F

22mm M

/15mm F

UNIVERSAL CONNECTOR

Page 29: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 153

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Disposable Infant Resuscitation Circuit with

Adjustable In-line PEEP Flow Controller Function

Features and Benefits:

Fits most Infant T-Piece Resuscitators (15mmM/10mmF connector) Easy to Use Adjustable PEEP Flow Controller PEEP Control Indexer Luer Port and Plug

TB3000 Disposable Infant Circuit with Adjustable Straight PEEP Flow Controller Function and Luer Port and Plug (PP) (PE) (PC)

Infant Care Products - Resuscitation Circuits

Luer Port

& Plug

15mm M

/10mm F

Disposable Infant Resuscitation Circuit with

Adjustable PEEP Flow Controller Function, Blow-off

Pressure Relief Valve and Security Lock

Features and Benefits:

Fits most Infant T-Piece Resuscitators (15mmM/10mmF connector) Blow-off Valve, 0~50 cmH2O Adjustable PEEP Double Swivel Connection Light Weight User Friendly

TB4000 Disposable Infant Circuit with Adjustable PEEP Flow Controller Function and Blow-off Valve with Security Lock (PP) (PE) (PC)

15mm F

PEEP Flow Controller

Disposable Infant Resuscitation Circuit with

Adjustable PEEP Flow Controller Function, Blow-off

Pressure Relief Valve with Security Lock and

Pressure Manometer Gauge

Features and Benefits:

Fits most Infant T-Piece Resuscitators (15mmM/10mmF connector) Blow-off Valve, 0~50 cmH2O Adjustable PEEP In-built Pressure gauge Double Swivel Connection Light Weight User Friendly

TB4500 Disposable Infant Circuit with Adjustable PEEP Flow Controller Function and Blow-off Valve with Security Lock and Pressure Manometer Gauge (PP) (PE) (PC)

15mm M

/10mm F

22mm M

/15mm F

Swivel

PEEP Flow

Controller

Swivel

Pressure

Manometer

15mm M

/10mm F

Blow-off

Valve

PEEP Flow Controller

22mm M

/15mm F

Swivel

Swivel

Page 30: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 154

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Infant Care Products - Resuscitation Circuits

Legend: M = Male (External) F = Female (Internal) (D) = Disposable ID = Inside Diameter (PP) = Polypropylene (PE) = Polyethylene (PC) = Polycarbonate

i-Puff® All-In-One Disposable

Infant Resuscitation Circuit

The i-Puff® is a disposable infant T-piece resuscitation circuit system capable of maintaining and displaying both peak inspiratory pressure (PIP) and positive end expiratory pressure (PEEP). The dedicated blow-off valve limits the set target pressure regardless of any inadvertent increase in flow to the circuit. This maximises patient protection from barotrauma.This circuit is designed to operate independent of any other resuscitation device.

Features and Benefits:

Fits most Infant T-Piece Resuscitators (15mmM/10mmF connector) Blow-off Valve, 0~50 cmH2O Adjustable PEEP PIP Controller Pressure Manometer Flowmeter Nipple Double Swivel Connection Light Weight User Friendly

TB5000-W i-Puff® Disposable All-in-One Infant Resuscitation Circuit (PP) (PE) (PC)

Blow-off

Valve

PEEP Flow

Controller

22mm M/15mm F

Swivel

Swivel

Pressure

Manometer

15mm M

/10mm F

Connects Directly to Flowmeter

OR

15mm M / 10mm F Adaptor

Australian Thread

Flowmeter

Nipple

(1/4" BSP)

10mm M

Disposable Gas Delivery Circuit with

Direct Connect Flowmeter Nipple (Australian Thread)

(Suitable for Neopuff™)

The New TB6000 series will be a new concept in supplying the gas delivery to the Neopuff™. The unique flowmeter nipple will allow operators to use 10mm tubing to go to the inlet of the neopuff thus allowing a greater volume of gas available to the patient

Features and Benefits:

Fits Neopuff™ Infant T-piece Resuscitator Flowmeter Nipple / Hose Adaptor Combination Light Weight Easy Connection

TB6000-W Disposable Gas Delivery Circuit (Suitable for Neopuff™) (PP) (PE) (PC)

Connects Directly to Flowmeter

OR

15mm M / 10mm F Adaptor

Australian Thread

Flowmeter

Nipple

(1/4" BSP)

15mm M

/10mm F

Page 31: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 155

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Oxygen Tube with Gas Inlet Connector

TB7000 2.1 m Oxygen Tube with Gas Inlet Connector Suitable for NeoPuff™

Luer Port

& Plug

PEEP Flow

Controller

15mm M

/10mm F

Swivel

22mm M

/15mm F

Swivel

Suction

Port

Disposable Infant Resuscitation Circuit with

Adjustable In-line PEEP Flow Controller Function and

Double Swivel Elbow Adaptor with Suction Port

and Plug

Features and Benefits:

Fits most Infant T-Piece Resuscitators (15mmM/10mmF connector) Blow-off Valve, 0~50 cmH2O Adjustable PEEP Double Swivel Connection Suction Port & Plug Light Weight User Friendly

TB9000 Disposable Infant Circuit with Adjustable PEEP Flow Controller Function and Double Swivel Elbow Adaptor with Suction Port and Plug (PP) (PE) (PC)

Infant Care Products - Resuscitation Circuits

US Thread

Flowmeter Nipple

(US 9/16 UNF)

15mm M

/10mm F

15mm M

/10mm F/10mm F

10mm M

Disposable Gas Delivery Circuit with Direct Connect

Flowmeter Nipple (US Thread) (Suitable for Neopuff™)

The New TB6000 series will be a new concept in supplying the gas delivery to the Neopuff™. The unique flowmeter nipple will allow operators to use 10mm tubing to go to the inlet of the neopuff thus allowing a greater volume of gas available to the patient

Features and Benefits:

Fits Neopuff™ Infant T-piece Resuscitator Flowmeter Nipple / Hose Adaptor Combination Light Weight Easy Connection

TB6000-G Disposable Gas Delivery Circuit (Suitable for Neopuff™)

(PP) (PE) (PC)

Connects Directly to Flowmeter

OR

15mm M / 10mm F Adaptor

10mm M

Page 32: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 156Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Legend: (Al) = Aluminium (Foam) = Polyethylene/Polyester

IV Arm Boards® Neonatal, Infant, Paediatric & Adult IV Arm Boards®

Disposable Soft and pliable Reduce discomfort to limb Easy to apply and remove Available in 7 sizes Firm, yet flexible aluminium insert to help keep profile

APM601 Micro-Neonatal IV Arm Board® with flexible aluminum insertSize 65mm x 29mm x 21mm (Pack of 50) (Al)(Foam)

APM602 Neonatal IV Arm Board® with flexible aluminum insertSize 100mm x 38mm x 30mm (Pack of 50) (Al)(Foam)

APM603 Infant IV Arm Board® with flexible aluminum insertSize 125mm x 45mm x 32mm (Pack of 30) (Al)(Foam)

APM603.5 Infant IV Arm Board®® with flexible aluminum insertSize 148mm x 40mm (Pack of 20) (Al)(Foam)

APM604 Paediatric IV Arm Board® with flexible aluminum insertSize 175mm x 50mm (Pack of 15) (Al)(Foam)

APM604.5 Paediatric IV Arm Board® with flexible aluminum insertSize 210mm x 65mm (Packet of 20) (Al)(Foam)

APM605 Adult IV Arm Board® with flexible aluminum insert Size 250mm x 80mm (Pack of 20) (Al)(Foam)

IV Arm Boards® with Securing Straps Neonatal, Infant, Paediatric & Adult IV Arm Boards® with Securing Straps

Disposable Soft and pliable Reduce discomfort to limb Easy to apply and remove Available in 7 sizes Firm, yet flexible aluminium insert to help keep profile Supplied with Securing Straps

APM601/WS Micro-Neonatal IV Arm Board® with flexible aluminum insertwith Securing Straps. Size 65mm x 25mm x 18mm (Pack of 50) (Al)(Foam)

APM602/WS Neonatal IV Arm Board® with flexible aluminum insert withSecuring Straps. Size 100mm x 35mm x 25mm (Pack of 50) (Al)(Foam)

APM603/WS Infant IV Arm Board® with flexible aluminum insert withSecuring Straps. Size 125mm x 45mm x 32mm (Pack of 30) (Al)(Foam)

APM603.5/WS Infant IV Arm Board® with flexible aluminum insert withSecuring Straps. Size 148mm x 40mm x 30mm (Pack of 30) (Al)(Foam)

APM604/WS Paediatric IV Arm Board® with flexible aluminum insert withSecuring Straps. Size 175mm x 50mm (Pack of 15) (Al)(Foam)

APM604.5/WS Paediatric IV Arm Board® with flexible aluminum insert withSecuring Straps. Size 210mm x 65mm (Pack of 15) (Al)(Foam)

APM605/WS Adult IV Arm Board® with flexible aluminum insert withSecuring Straps. Size 250mm x 80mm (Pack of 20) (Al)(Foam)

APM601

APM602

APM603

APM603.5

APM604

APM604.5

APM605

Infant Care Products - IV Arm Boards

APM601/WS

APM602/WS

APM603/WS

APM603.5/WS

APM604/WS

APM604.5/WS

APM605/WS

Page 33: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 157Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Infant Care Products - IV Armboards

This page is intentionally blank

Page 34: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 158Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Neonatal SpO2 Probe Cover / Securing Strap

Disposable Easy to apply and remove Soft and gentle Velcro™ tie allows repeated opening and closing

B905 Neonatal SPO2 Probe Cover with Velcro™ tie For use with SPO2 sensor Size 35mm x 135mm (Foam)(Nylon)

B907 Neonatal Securing Strap with Velcro™ tie Suits APM601 to APM603 IV Arm Boards Size 150mm x 15mm (Foam)(Nylon)

B908 Securing Strap with Velcro™ tie Suits APM604 IV Arm BoardsSize 210mm x 25mm (Foam)(Nylon)

Umbilical Clamps (Single Patient Use)

Dual Grip Surface Interlocking Teeth Locking Clip Finger Grip Special Hinge Design Single Packed Sterile (EtO)

PH-UC1000 Umbilical Clamps STERILE (Box of 50)

PH-UC1000-NS Umbilical Clamps NON-STERILE (Box of 250)

MRI Safe IV Arm Board

Disposable Durable PVC Eliminates movement of limb Easy to use

APM304-P MRI Safe IV Arm Board (PP)

Infant Care Products

Umbilical Clamp Cutters (Single Patient Use)

Easily Cuts Umbilical Clamps Medical Grade Plastic Single Hand Operational Single Packed Sterile (EtO)

PH-UC3000 Umbilical Clamp Cutter (Box of 10) STERILE EO

B905

B907

B908

Legend: (Foam) = Polyethylene/Polyester (EtO) = Ethylene Oxide (Sterilisation Agent) (PP) = Polypropylene (Nylon) = Nylon Polymer

Page 35: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 159

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Infant Care Products

NeoShades® with TabsPhototherapy Eye Shades with Tabs

Soft, padded eye shield material with cute sunglasses design Skin friendly NeoBond® Hydrocolloid tabs hold NeoShades® in place Not made with natural rubber latex or plasticiser DEHP Individually packaged

Standard

N720 NeoShades® Phototherapy Eye Shields (Micro)

N721 NeoShades® Phototherapy Eye Shields (Small)

N722 NeoShades® Phototherapy Eye Shields (Large)

Box of 50

NeoShades® with HeadstrapPhototherapy Eye Shades with NeoFoam™ Headstrap

Soft, padded eye shield material with cute sunglasses design Ocular pockets designed for patient comfort and safety Soft, patented NeoFoam® headstrap holds NeoShades in place Adjustable headstrap engineered to minimize slipping and help reduce

head molding Unique headstrap shape designed to ensure ideal fit Not made with natural rubber latex or plasticiser DEHP Individually packaged

N727 Phototherapy Eye Shields with headstrap (Micro)

N728 Phototherapy Eye Shields with headstrap (Small)

N729 Phototherapy Eye Shields with headstrap (Large)

Box of 50

Page 36: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 160

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Snorkel™Multi-purpose Suction Device

Designed for single handed suctioning Thumb port for intermittent suctioning Soft, flexible tip similar to a bulb syringe Clear handle for better visualization Not made with natural rubber latex or plasticiser DEHP Individually packaged

N275 “Snorkel” Multi-purpose Suction Device

Suction Caddy™ Suction Device Holder for Little Sucker

Easy to use and attaches to most smooth surfaces Keeps suction devices and tubing close at hand and off the floor Convenient, designated write-on area for patient name and date Clear plastic allows for better visibility Tubing anchor helps to reduce noise Large suction cups provide strong hold and allow for easy removal Not made with natural rubber latex or plasticiser DEHP Individually packaged

N245 Suction Caddy

Infant Care Products

Meconium Aspirator® Meconium Removal Device that Allows Intermittent Suction

Designed to eliminate mouth suctioning of meconium Suction control port for intermittent suctioning Attaches to most endotracheal tubes Featured in the Textbook of Neonatal Resuscitation Yellow colour allows for easier identification Not made with natural rubber latex or plasticiser DEHP Individually packaged

N0102 Yellow Meconium Aspirator

Neoseal®

Provides Comfortable Seal for Nasal Prong CPAP

Protects the skin of the septum and nares Designed to improve the seal for more effective respiratory support Not made with natural rubber latex or plasticiser DEHP

N420 Neoseal MicroN421 Neoseal Small N422 Neoseal Large

Page 37: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 161

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Infant Care Products

NeoBar® ET Tube Holder with gentle hydrocolloid adhesive tabs

Skin friendly NeoBond® Hydrocolloid tabs Macro and Jumbo sizes available with medical grade acrylic adhesive Designed to reduce extubations, help prevent palate trauma and allow for

better oral care Eliminates need for tape near nose or mouth Can be cut for emergency removal Color coded sizes Not made with natural rubber latex or plasticiser DEHP Individually packaged

N709 NeoBar® ET Tube Holder - Mini - Purple (5/pkt) N710 NeoBar® ET Tube Holder - Ultra - Yellow (5/pkt) N711 NeoBar® ET Tube Holder - Micro - White (5/pkt) N712 NeoBar® ET Tube Holder - Small - Green (5/pkt) N713 NeoBar® ET Tube Holder - Large - Blue (5/pkt) N714 NeoBar® ET Tube Holder - XL - Rose (5/pkt) N715H NeoBar® ET Tube Holder - Macro - Clear (5/pkt) N716H NeoBar® ET Tube Holder - Jumbo - Grey (5/pkt)

With Medical Grade Acrylic Adhesive

N715F NeoBar® ET Tube Holder - Macro - Peach (5/pkt)

N716F NeoBar® ET Tube Holder - Jumbo - Carbon (5/pkt)

N301

N315

NeoLead® Pre-wired Neonatal ECG Electrodes

All leads are pre-wiredAll leads have hydrogel center

Produces excellent tracings Safe on neonatal skin Won’t dry out prematurely

All leads have hydrocolloid border

Provides long term attachment Prevents gel from oozing out the edges Safe on neonatal skin Improves sensor stability

Radiolucent NeoLead (N305)

Doesn’t show up on x-raysPedLead (N315)

Two channel continuous monitoring Radiolucent materials allow for x-ray

N301 Standard NeoLead® - Small N305 Radiolucent NeoLead® - Small N315 Paediatric NeoLead® - Small

Size 25mm Circle

Boxes of 20

HydrocolloidBorder

HydrogelCentre

Page 38: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 162

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Micro NeoLead®

Pre-wired No cumbersome band Safely secures to limbs without a strap that could reduce circulation Gentle hydrocolloid ends and hydrogel adhesives Long lasting and easy to use, even under high humidity Radiolucent

N306 Radiolucent Micro NeoLead® - Micro

Size 20mm x 10mm

Boxes of 20 sets

Mini NeoLead® Pre-wired Neonatal ECG Electrodes

Pre-wired Unique electrode uses both hydrocolloid and hydrogel adhesives Hydrocolloid border provides added stability, and excellent tracings Long lasting and easy to use, even under high humidity Prevents gel from oozing out the edges

N300 Radiolucent Micro NeoLead® - Mini

Size 19mm Circle

Boxes of 20 sets

N601

N602B N602P N603

NeoGrip® Multi-Purpose Tubing and Cable Holders

Relieves stress on tubes, cables and circuits and keeps them together Allows for better patient mobility Attaches to linen or clothing without damaging Ideal for kangaroo care Open and close repeatedly with no residue Can be used in clinical or home care setting Great for ambulatory patients N603 (white) can be sterilized Not made with natural rubber latex or plasticiser DEHP

N601 NeoGrip® - Tubing and cable holder - Teal

N602B NeoGrip® - Tubing and cable holder - Blue

N602P NeoGrip® - Tubing and cable holder - Pink

N603 NeoGrip® - Tubing and cable holder - White

Boxes of 40

Infant Care Products

HydrogelCentre

HydrocolloidBorder

Similiar size to 5 cent piece.

Page 39: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 163

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Infant Care Products

NeoBridge® Umbilical Catheter Holder with Secure Positioning Flaps

Skin friendly NeoBond® Hydrocolloid base Secure positioning flaps designed to relieve stress on tubes and help prevent

dislodgement Accommodates two catheters Flap designed to be opened and closed repeatedly Clear flap allows for better visibility Not made with natural rubber latex or plasticiser DEHP

N700 NeoBridge® Umbilical Catheter Holder - Micro

N701 NeoBridge® Umbilical Catheter Holder - Small

N702 NeoBridge® Umbilical Catheter Holder - Large

Boxes of 20

Hold-A-Line™

Catheter and Tubing Holder

Skin friendly NeoBond® Hydrocolloid base Designed to relieve stress on tubes and help prevent dislodgement Flap designed to be opened and closed repeatedly Clear flap allows for better visibility Unique shape allows for larger umbilical stumps Not made with natural rubber latex or plasticiser DEHP

N705 Hold-A-Line™ - Standard

Boxes of 40

N700

N701

N702

EZ-Hold® Tubing and Cannula Holder

Skin friendly NeoBond® Hydrocolloid base Fold over flap engineered to reduce stress on tubes Flap designed to be opened and closed repeatedly Clear flap allows for better visibility Mini size and shape ideal for micro preemies Not made with natural rubber latex or plasticiser DEHP

N756 Tubing and Cannula Holder - Mini

N757 Tubing and Cannula Holder - Standard

Boxes of 100

N756

N757

Page 40: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 164

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Infant Care Products

NeoBond®

Medical Grade Hydrocolloid Strips

Skin friendly alternative to acrylic tape Developed for long term attachment Ideal for use with limb boards Not made with natural rubber latex or plasticiser DEHP

N741 NeoBond® Medical Grade Hydrocolloid Strips Size 12.7mm x 152.4mm (1/2” x 6”)

1 Roll per Box

NeoSmile™ Temperature Probe Cover

Temperature probe cover that attaches to patients with NeoBond® Hydrocolloid Resists skin breakdown from moisture or heat Doesn’t fall off prematurely

N731 NeoSmile™ - Temperature Probe Cover with NeoBond® Hydrocolloid Size 25mm Ø

Boxes of 150

Neotech Chinstrap™

Respiratory Support Accessory

Soft, breathable, skin friendly NeoFoam® wicks perspiration Flexibility enables minimal mouth movement Form fitting and adjustable Split chin design for comfort and stability Ear openings to prevent folding over Designed to reduce the risk of pressure ulcers or necrosis Unique material helps to prevent sliding Not made with natural rubber latex or plasticiser DEHP Individually packaged

N785 Micro 28cm-35cm* N786 Small 33cm-42cm* N787 Large 36cm-46cm*

* Circumference measurement from Chin to back of head

Boxes of 20

Page 41: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 165

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

NeoPulse™ Adjustable and Disposable Pulse Oximeter Wrap

Soft, breathable, skin friendly NeoFoam® wicks perspiration Lightweight, form fitting and adjustable Designed for comfort and stability Not made with natural rubber latex or plasticiser DEHP Individually packaged

N781 NeoPulse™ Pulse Oximeter Wrap - Small Size 19mm x 75mm N782 NeoPulse™ Pulse Oximeter Wrap - Large Size 25mm x 125mm N783 NeoPulse™ Pulse Oximeter Wrap - X-Large Size 50mm x 150mm

Boxes of 100

Neotech Neospoon™

Disposable Measuring Spoon

Dual spoon design (1/8 tsp and 1/2tsp) Engineered for fast, accurate measuring Dispense exact volume in multiples of 1/8 tsp Ideal for feeding preparation Environmentally friendly, biodegradable material Not made with natural rubber latex or plasticiser DEHP Individually packaged

N761 Neospoon 1/8 tsp - 1/2 tsp

Boxes of 100

Duotube Silicone Binasal Pharangeal Airways (PS)(S)

Easy to insert and remove Reduces Septal and nares trauma Made from soft latex free silicone Available in 3 sizes Available in 2 lengths Stays securely in place

20mm Tube length

95-02504 15mm M to 2.5mm Dia. Duotube 95-03004 15mm M to 3.0mm Dia. Duotube 83-03504 15mm M to 3.5mm Dia. Duotube

35mm Tube length

97-02504 15mm M to 2.5mm Dia. Duotube 97-03004 15mm M to 3.0mm Dia. Duotube 85-03504 15mm M to 3.5mm Dia. Duotube

Packets of 10

Infant Care Products

15mm M

20mm

35mm

20mm Duotube

35mm Duotube

15mm M

Page 42: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 166

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Infant Care Products

EZCare™ Tracheostomy Tube Holder

Neoprene material is soft, lightweight and comfortable, and won’t irritate the skin

Provides stable attachment and reduces chance of accidental dislodgement Moisture resistant material allows patient to be bathed without removing

holder Stretchable material allows for cough reflex Colorful straps help resist staining

Part No. Strap Size Neck Size

N905 EZCare™ 127mm 180-205mm

N906 EZCare™ 152mm 203-230mm

N907 EZCare™ 178mm 230-254mm

N908 EZCare™ 203mm 254-280mm

N909 EZCare™ 230mm 280-305mm

N910 EZCare™ 254mm 305-330mm

Packets of 5

NOTE: Tracheostomy tube not included

EZCare Softouch™

Disposable Tracheostomy Tube Holder

Soft, breathable, skin friendly NeoFoam® wicks perspiration Lightweight, form fitting and adjustable Designed for comfort and stability Not made with natural rubber latex or plasticiser DEHP Individually packaged

Patient Size N924 EZCare™ Small 230mm (9”)

N925 EZCare™ Medium 330mm (13”)

N926 EZCare™ Large 460mm (18”)

Boxes of 50

NOTE: Tracheostomy tube not included

Pink(PK)

Camouflage(CO)

Blue(BL)

Hawaiian(HN)

Page 43: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 167

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Infant Care Products

RAM Cannula®

Neonatal Cannulas with Soft, Curved Prongs

for use with low/high flow oxygen Can be used with or without humidity Soft, curved prongs Color coded sizes 15mm oxygen tubing adapter included Not made with natural rubber latex or plasticiser DEHP Individually packaged

Little Sucker® Oral & Nasal Suction Devices for Gentle and Effective Suctioning

Little Sucker®

Designed for single handed suctioning Thumb port for intermittent suctioning Soft, flexible tip like a bulb syringe Not made with natural rubber latex or plasticiser DEHP Individually packaged

Little Sucker® Cover Designed to protect the Little Sucker from damage, debris and external contaminants Bright blue color for better visibility Noise reducing port plug Not made with natural rubber latex or plasticiser DEHP Individually packaged

Little Sucker® Nasal Tip Specialized tip designed to minimize potential tissue trauma Designed for single handed suctioning Thumb port for intermittent suctioning Soft, flexible tip similar to a bulb syringe Not made with natural rubber latex or plasticiser DEHP Individually packaged

N204 Oral & Nasal Suction Adaptor - Preemie

N204C Oral & Nasal Suction Adaptor with Cover

N205 Oral & Nasal Suction Adaptor - Standard

N205C Oral & Nasal Suction Adaptor with Cover

N215 Cover Only

N224 Nasal Suction Adaptor - Preemie Tip

N225 Nasal Suction Adaptor - Standard

N204

N205C

N225

N205 N224

Little Sucker Cover®

Suction Device Protective Cover

Little Sucker® Nasal TipNasal Suction Device

Little Sucker®

Oral and Nasal Suction Device

N4820O2 Adaptor

Colour Coded O-rings:

Micro-Preemie = White

Preemie = Green

Newborn = Blue

Infant = Orange

Small = Yellow

Medium = Teal

Large = Purple

Colour Coded O-ringsPart

NumberItem Qty / Unit Colour

N4900 Micro Preemie 10/box White

N4901 Preemie 10/box Green

N4902 Newborn 10/box Blue

N4903 Infant 10/box Orange

N4904 Small 10/box Yellow

N4905 Medium 10/box Teal

N4906 Large 10/box Purple

N4820 Oxygen Tubing Adapter 50/box

Page 44: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 168

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Infant Care Neonate Nappies

BIDIBOTS NAPPIES

Bidibots have dsigned and created a new range of nappies in three sizes that cater for a weight range between 500 grams up to 2 kg. Our nappy has:

Higher absorbency for less handling Nappy to sit under umbilical cord for easy access points Effective hook and loop to decrease risk of tapes sticking to babies skin Narrow in groin for optimal hip positioning Increase leg elasticity for decrease risk of leakage Wetness indicators for nurses.

We are very proud of the outcome on this product and the journey we all took to get there, and we know our precious neonates will be very grateful to have theBidibots nappy and its medical benefits.

The nappy is now available in three sizes to cater for weight ranges between 500 grams up to 2 kg.

KEY FEATURES

Shortfalls were identified in existing Neonatal products. Bidibots came up with the following solutions;

The design and cut of the existing nappies were not good for the hips and greater posture of the developing skeleton of a premature baby. Solution: We have designed and built a tailored crutch based on physiological data provided from paediatric experts into Bidibots nappy.

The fastening systems of the existing nappies were abrasive and could lead to scaring of the delicate skin of a premature baby.

Solution: We have replaced the outdated fastening systems with a soft touch fastening system designed for these sorts of products.

The key access point for premature babies is the belly button which gets covered by the existing nappies.

Solution: We have designed and built tailored low cut front based on physiological data provided from paediatric experts into the Bidibots nappy.

The absorbency of the nappies were at Iow levels leading to two main issues;- increased risk of septic complications.

Solution: We have increased the absorption levels of the Bidibots nappy and also added a wet indicator to show the Neonatal nursing staff when the nappy is ready for changing.

Higher numbers of nappy changes of nappies per day which increases risk of injury to the premature baby.

Solution: We have increased the absorption levels of the Bidibots nappy and also added a wet indicator to show the Neonatal nursing staff when the nappy is ready for changing.

ORDER CODES:

PH-NP001 Bidibots NappySize SmallWeight: 500 - 750gQty Per Bag: 30 Nappies

PH-NP002 Bidibots NappySize MediumWeight: 750 - 1250gQty Per Bag: 30 Nappies

PH-NP003 Bidibots NappySize LargeWeight: 1250 - 2000gQty Per Bag: 30 Nappies

PH-NP001

PH-NP002

PH-NP003

Small

Medium

Large

Page 45: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 169

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Infant Care Products

Comepa Neonatal ECG Electrodes

MFBB.RENS.60 Comepa Pre-gelled Rectangular Electrode

NEW & IMPROVED water-proof backing Improving adhesion in high humidity conditions.

Silicone Nipple Shields

Easy to apply and use Reduce pain from cracked nipples Soft silicone material Latex free

51410 Nipple Shields (2 per pack) (S)

Atom Test Lung

60298 Test Lung 50ml Capacity

BM200 BM400 BM500

Masimo Disposable & Reusable SpO2 Sensors

NELLCOR COMPATIBLE DISPOSABLE AND

REUSABLE SPO2 SENSORS

BM-200 Neonatal/Adult Disposable Foot Sensor BM-400 Paediatric Disposable Finger Sensor BM-500 Infant Disposable Big Toe Sensor BM-600 Reusable Multisite Sensor BM-2024 NELLCOR Extension Cable

MASIMO LNCS ADHESIVE SENSORS

2258 Y1, Multisite Reusable Sensor 2328 Infant (3-20kg) 20/box 2329 Neonatal (<3kg >40kg) 20/box

MASIMO LNCS CABLES

1814 14 Pin Patient Cable (3.0m) 2017 14 Pin Patient Cable (1.2m) 2055 20pin Patient Cable (1.2m) 2056 20pin Patient Cabe (2.4m)

MASIMO RD SET ADHESIVE SENSORS

4003 Neonatal (<3kg >40kg) 20/box 4002 Infant (3-20kg) 20/box

MASIMO RD CABLES

4080 14 Pin RD Set Patient Cable (5ft / 1.5m) 4081 14 Pin RD Set Patient Cable (12ft / 3.5m)4103 20 Pin RD Patient Cable (5ft / 1.5m) 4104 20 Pin RD Patient Cabe (12ft / 3.5m)

Page 46: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 170

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Infant Nasal CPAP

CPAP Kit in Blister Pack (PP) (PE) (C) (PVC)Kit Consists of: Nasal Prong, 1.2m x Natural 10mm ID Tubing, 1.2m x Blue 10mm ID Tubing, CO2 Line, Bonnet, Velcro Strips and 2 x 10mm Connectors

Part No. Size Description

PH12000 0 Complete CPAP Kit in blister case

PH12001 1 Complete CPAP Kit in blister case

PH12002 2 Complete CPAP Kit in blister case

PH12003 3 Complete CPAP Kit in blister case

PH12004 4 Complete CPAP Kit in blister case

PH12005 5 Complete CPAP Kit in blister case

CPAP Kit with Bonnet and Velcro in Blister Case (PP)(C)(PE)

Part No. Size Description

PH12000-3 0 Prong with adaptor x4, Bonnet and Velcro in blister case

PH12001-3 1 Prong with adaptor x4, Bonnet and Velcro in blister case

PH12002-3 2 Prong with adaptor x4, Bonnet and Velcro in blister case

PH12003-3 3 Prong with adaptor x4, Bonnet and Velcro in blister case

PH12004-3 4 Prong with adaptor x4, Bonnet and Velcro in blister case

PH12005-3 5 Prong with adaptor x4, Bonnet and Velcro in blister case

equin- Supplied in Poly Bag (PP) (PVC)

Part No. Size Description PH12000-2 0 Prong with adaptor x4 in poly bag

PH12001-2 1 Prong with adaptor x4 in poly bag

PH12002-2 2 Prong with adaptor x4 in poly bag

PH12003-2 3 Prong with adaptor x4 in poly bag

PH12004-2 4 Prong with adaptor x4 in poly bag

PH12005-2 5 Prong with adaptor x4 in poly bag

Patient Weight Suggested Size Suggested Part Number

< 700 grams 0 (7.5fr) PH12000 / PH12000-2 / PH12000-3

700~1250 grams 1 (10fr) PH12001 / PH12001-2 / PH12001-3

1250~2000 grams 2 (12.5fr) PH12002 / PH12002-2 / PH12002-3

2000~3000 grams 3 (15fr) PH12003 / PH12003-2 / PH12003-3

> 3000 grams 4 (16fr) PH12004 / PH12004-2 / PH12004-3

1~2 years 5 (20fr) PH12005 / PH12005-2 / PH12005-3

SUGGESTED SIZE SELECTION CHART

Page 47: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 171

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

CPAP Adaptors (PP) Individual CPAP Adaptors

CPAP1001 Straight Tubing Connector c/w Luer Lock

CPAP1002 90° Connector

CPAP1003 90° Connector c/w Luer Lock

CPAP1004 Straight Tubing Connector

10mm ID Plastic Tubing - 30m Roll Natural

MP-CO10N30M-12 10mm ID NATURAL Corrugated Plastic Disposable Tubing 30m Roll, Cuff every 300mm (12”) (PE)

10mm ID Plastic Tubing - 30m Roll Blue

MP-CO10B30M-12 10mm ID BLUE Corrugated Plastic Disposable Tubing 30m Roll, Cuff every 300mm (12”) (PE)

10mm ID Plastic Tubing - 30m Roll Pink

MP-CO10P30M-12 10mm ID PINK Corrugated Plastic Disposable Tubing 30m Roll, Cuff every 300mm (12”) (PE)

CPAP1001

CPAP1002

CPAP1003

CPAP1004

10mm M

10mm M

10mm M

10mm M

10mm M

10mm M

6mm ID Tube

6mm ID Tube

Luer

Lock

Luer

Lock

Infant Nasal CPAP

Page 48: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 172

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Infant Care Products

Atom Baby Stethoscopes

for Premature/Newborn Baby

Includes: Y-tube, Chest-piece, Diaphragm (for premature/newborn baby)

60277 Atom Baby Stethoscope (Pink)

60278 Atom Baby Stethoscope (Light Grey)

Spare Parts:

Y-tube pinkY-tube light greyChest piece w/Diaphragm (for premature/newborn baby)Diaphragm (for premature/newborn baby)Diaphragm (for infant)

NOTE: The diaphragm can be replaced easily and it is used in auscultation from premature babies to infants.

Animal Stethoscopes

A NEW fun style of infant stethoscope with professional built-in sound centraliser. A delightful experience for children who are often frightened by conventional stethoscope designs.

The Stethoscope comprises of a deluxe binaural with inner spring and chest piece made from steel & plastic.

Available in 5 Tube Colours Includes 7 x Inter-changeable Animal Face Plates Built-in Sound Centraliser Deluxe binaural inner spring Chest piece made from steel & plastic

CKF606PF-Y (Yellow Tube Colour)

CKF606PF-W (White Tube Colour)

CKF606PF-B (Blue Tube Colour)

CKF606PF-P (Pink Tube Colour)

CKF606PF-G (Green Tube Colour)

60277 (Pink)

60278 (Light Grey)

Page 49: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 173

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Self-administered Analgesic Unit

Equinox® Advantage Analgesia Dispenser Unit

The Equinox® Advantage Oxygen/Nitrous Oxide Mixing and Delivery System allows you to control the mix of nitrous oxide and oxygen a patient is receiving in order to provide the appropriate dose for the patient and the procedure. Designed for use everywhere from the pre-hospital (ambulance), In-hospital (ER, Labor and Delivery etc.) and Dental (Surgical Procedures), the portable Equinox® Advantage system is easy to use, and eliminates the risk of delivering a hypoxic mixture.

Features:

Small Lightweight and transportable Designed to deliver a variable mix of Oxygen and Nitrous Oxide with minimal

inspiratory effort Easy to Use Patient administered High demand flow Audible and Visual Gas Supply Indicators O2 Enrichment Button

PHG300-H Equinox® Advantage N2O/O2 Analgesic Gas Mixing and Delivery System c/w O2 and N2O gas supply hoses

Optional Accessories:

TM111/T.EA 5-leg Mobile Trolley

TM111/T.BHEA 5-leg Mobile Trolley with 2 x "D" Size Bottle Holders

Consumables:

MC/4001 3.0m Disposable Patient Circuit with Filter and Mouthpiece MC/4003 3.0m Disposable Patient Circuit with Filter, Mouthpiece and 3.0m Pink Scavenge Tubing with 19mm M Connector

PHG300-H

TM111/T.EA

TM111/T.BHEA

Optional Accessories:

Equinox® Advantage

See Page 176 + 177

Page 50: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 174

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

GAS-EVAC Nitrous Oxide Scavenge Device

Avoid the risks of over-exposure to patient

expired gases.

Nursing and medical staff are being exposed to passive inhalation of patient-expired relative analgesic gases. The exposure standard for N2O is a time-weighted average of no more than 25ppm. Australian studies have found hospitals using Relative Analgesia (RA) apparatus without scavenging had measured levels much higher than 25ppm.

Side-effects of chronic exposure to N2O include:

Reduced fertility in women and men

Spontaneous abortion in pregnant women

Neurological disorders

Renal complications and liver disease

Decrease in mental performance, audiovisual ability and manual dexterity.

Gas-Evac™ has been specifically designed to significantly reduce the levels of workplace exposure to patient-expired gases for medical professionals.

Gas-Evac™ benefits

Reduces N2O in the workplace to well below the recommended maximum of 25ppm

Provides the safe and cost-effective solution for environments where existing scavenging may be inadequate

Reduces exposure to future OH&S risk

Helps ensure your workplace meets exposure standards [NOHSC:3008(1995)]

How does Gas-Evac™ work?

Unique turbulence chamber enables your existing scavenge system to keep up with the high-volume expiration of a heavily-respirating patient.

Dual-limbed fresh gas/scavenge circuits incorporate a non-return valve which eliminates the possibility of a patient re-breathing expired gases.

ISO fittings eliminate the possibility of incorrect connections.

Connects to any existing suction or scavenge wall outlet to safely remove high volumes of expired gas from the immediate work area.

Available as a mobile pedestal or as a wall-mounted unit, to suit all patient installations.

PH-GE1000 Gas-Evac™ Pedestal Unit (pictured)

PH-GE2000 Gas-Evac™ Wall Mounted

PH-GE3000 Gas-Evac™ Pedestal Unit with Bottle Holders

PH-GE1000 shown with Equinox Advantage mounted

Page 51: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 175

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

MC/3200 Disposable Breathing Circuit **120 Tube length = 3.0 metre (120”)

MC/3300 Disposable Breathing Circuit **60 Tube length = 1.5 metre (60”)

Consisting of:A. MC/HP Handpiece 22mm M with one-way valve (SY)(S)B. 56001 Mouthpiece 22mm F (HDPE)C. MP-EX22B** 22mm ID Blue Expandable Tubing (PP)

A. B.

A. B. C.

D.

22mm F

MC/3200/F Disposable Breathing Circuit **120 Tube length = 3.0 metre (120”)

MC/3200/F/SH Disposable Breathing Circuit **136 Tube length = 3.5 metre (136”)

MC/3300/F Disposable Breathing Circuit **60 Tube length = 1.5 metre (60”)

Consisting of:A. MC/HP Handpiece 22mm M with one-way valve (SY)(S)B. 55000104-500 In-line Filter 22mm M/F (PP)C. 56001 Mouthpiece 22mm F (HDPE)D. MP-EX22B** 22mm ID Blue Expandable Tubing (PP)

C.

A. B. C.

22mm F

22mm F

D.E.

A. B. C.

D.

22mm F

MC/3200/F/A Disposable Breathing Circuit

Consisting of:A. MC/HP Handpiece 22mm M with one-way valve (SY)(S)B. 55000104-500 In-line Filter 22mm M/F (PP)C. 56001 Mouthpiece 22mm F (HDPE)D. MP-EX22B120 22mm ID Blue Expandable Tubing (PP)E. PH3000(D) Adaptor 22mm M to 22mm F (PP)

Tube length = 3.0 metre (120”)

MC/3200/F/M* Disposable Breathing Circuits

Consisting of:A. MC/HP Handpiece 22mm M with one-way valve (SY)(S)B. 55000104-500 In-line Filter 22mm M/F (PP)C. Inflatable Mask with Hook, Size 2 or 4 (refer below) (PVC)(SS)(R)(PP)D. MP-EX22B120 22mm ID Blue Expandable Tubing (PP)

Tube length = 3.0 metre (120”)

MC/3200/F/M2 Circuit, Inflatable Mask with Hook, Size #2 MC/3200/F/M4 Circuit, Inflatable Mask with Hook, Size #4

Legend: M = Male F = Female ID = Inside Diameter (PP) = Polypropylene (SY) = Styrene (PVC) = Polyvinyl Chloride (HDPE) = High Density Polyethylene (SS) = Stainless Steel (R) = Rubber (S) = Silicone

Disposable Mid-O-Gas / Analgesia Breathing Circuits

Page 52: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 176

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Disposable Mid-O-Gas / Analgesia Breathing Circuits

22mm F 22mm FMid-O-Gas / Analgesia Circuits

MC/3000 Disposable Breathing Circuit A. MP-EX22P120 22mm ID Pink Expandable Tubing (PP) B. MC-HP Handpiece 22mm M/M/M with one-way valve (SY)(S)C. 56001 Mouthpiece 22mm F (HDPE)D. MP-EX22B120 22mm ID Blue Expandable Tubing (PP)

MC/3000/SA Disposable Breathing Circuit (with Scavenge Adaptor)Above circuit including Scavenge Adaptor.E. PH3200(D) Adaptor 22mm M to 19mm M (PP)

Tube lengths = 3.0 metre (120”)

Scavenge Adaptor

Supplied withMC/3000/SA

22mm M

19mm M

B. C.

A. D. E.

Legend: M = Male F = Female ID = Inside Diameter (PP) = Polypropylene (SY) = Styrene (PVC) = Polyvinyl Chloride (HDPE) = High Density Polyethylene (SS) = Stainless Steel (R) = Rubber (S) = Silicone

22mm F22mm F

E.

A. B. C.

D.

Equinox Advantage Analgesia Circuits

MC/4001 Equinox Advantage Single Limb Circuit 3.0m Disposable Patient Circuit with Filter and Mouthpiece Consisting of:A. MC-HP Handpiece 22mm M/M/M with one-way valve (SY)(S)B. 55000104-500 In-line Filter 22mm M/F (PP)C. 56001 Mouthpiece 22mm F (HDPE)D. PH70018 One-way valve 22mm M/F (PP) (S) E. MP-EX22B120 22mm ID Blue Expandable Tubing (PP)

22mm F 22mm F

Mid-O-Gas / Analgesia Circuits

MC/3000/F Disposable Breathing Circuit

Consisting of:A. MP-EX22P120 22mm ID Pink Expandable Tubing (PP) B. MC-HP Handpiece 22mm M/M/M with one-way valve (SY)(S)C. 55000104-500 In-line Filter 22mm M/F (PP)D. 56001 Mouthpiece 22mm F (HDPE)E. MP-EX22B120 22mm ID Blue Expandable Tubing (PP)

MC/3000/F/SA Disposable Breathing Circuit (with Scavenge Adaptor) Above circuit including Scavenge Adaptor.F. PH3200(D) Adaptor 22mm M to 19mm M (PP)

MC/3000/F/M* Disposable Breathing CircuitAbove circuit including Mask in lieu of mouthpiece.* Mask size must be stated at ordering (refer below).G. Mask: (PVC)(SS)(R)(PP)

MC/3000/F/M2 Circuit with Size 2 Mask MC/3000/F/M3 Circuit with Size 3 Mask MC/3000/F/M4 Circuit with Size 4 Mask MC/3000/F/M5 Circuit with Size 5 Mask

Tube lengths = 3.0 metre (120”)

A. B. C. D.

Mask Sizes:

#2 - Paediatric#3 - Large Paediatric#4 - Adult#5 - Large Adult

E. G.

Scavenge Adaptor

Supplied withMC/3000/F/SA

22mm M 19mm M

F.

Page 53: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 177

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Equinox Advantage Analgesia Circuits

MC/4003 Equinox Advantage Circuit with Scavenge Limb

3.0m Disposable Patient Circuit with Filter, Mouthpiece and 3.0m Pink Scavenge Tubing with 19mm M Connector

Consisting of:A. MP-EX22P120 22mm ID Pink Expandable Tubing (PP) B. MC-HP Handpiece 22mm M/M/M with one-way valve (SY)(S)C. 55000104-500 In-line Filter 22mm M/F (PP)D. 56001 Mouthpiece 22mm F (HDPE)E. PH70018 One-way valve 22mm M/F (PP) (S)F. MP-EX22B120 22mm ID Blue Expandable Tubing (PP)G. PH3200(D) Adaptor 22mm M to 19mm M (PP)

19mm M 22mm F

A. F.

B. C. D.

E.

G.

22mm F

22mm M

/15mm F

Handpiece Assembly

MC/3500 Disposable Circuit Components

Consisting of: A. MC-HP Handpiece 22mm M/M/M with one-way valve (SY)(S)B. 56001 Mouthpiece 22mm F (HDPE)

22mm ID Extension Tubing

MC/180/BET Disposable Circuit Extender **72 Tube Length = 1.8 metre (72”)

MC/300/BET Disposable Circuit Extender **120 Tube Length = 3.0 metre (120”)

Consisting of:A. MP-EX22B** 22mm ID Blue Expandable Tubing (PP) B. PH3100(D) 22mm M/15mm F Adaptor (PP)

Handpiece Assembly with Filter

MC/3500/F Disposable Circuit Components

Consisting of: A. MC-HP Handpiece 22mm M/M/M with one-way valve (SY)(S)B. 55000104-500 In-line Filter 22mm M/F (PP)C. 56001 Mouthpiece 22mm F (HDPE)

22mm M

22mm M

A. B.

A. B. C.

A. B.

Disposable Mid-O-Gas / Analgesia Breathing Circuits and Accessories

Page 54: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 178

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Obstetric Doppler Systems

Elite 100 & 200 - Configurable Pocket Doppler The Elite is a configurable pocket sized ultrasound Doppler used to determine foetal viability . Available in a variety of configurations.

Elite 100 - Non-digital, non-rechargeable

EN30 Elite 100 with 3 MHz probe EN2W Elite 100 with 2 MHz waterproof probe

Elite 100 - Non-digital, rechargeable

EN30R Elite 100R with 3 MHz probe EN2WR Elite 100R with 2 MHz waterproof probe

Elite 200 - Digital, non-rechargeable

ED30 Elite 200 with 3 MHz probe ED2W Elite 200 with 2 MHz waterproof probe

Elite 200 - Digital, rechargeable

ED30R Elite 200R with 3 MHz probe ED2WR Elite 200R with 2 MHz waterproof probe

NOTE: The above units can be ordered with a combination of Vascular AND Obstetric Probes

Elite Probes

VASCULAR N500 Vascular 5MHz Probe N800 Vascular 8MHz Probe

OBSTETRIC

N200 Obstetric 2MHz Probe NW20 Obstetric Waterproof 2MHz Probe N300 Obstetric 3MHz Probe

Elite Accessories:

DS-1577 Rollstand with Anti-theft Mounting Bracket, Stainless Steel Construction, Weighted 5 Leg Base, 50mm Twin Nylon Castors, 25mm Diameter Pole, Nylon Coated Basket and Clamp & Anti-Theft Bracket

DS-1577Elite Rollstand with Anti-

theft Mounting Bracket

& Storage Basket

(Doppler Not Included)

Elite Rollstand

Digital, rechargeable3MHz or 2MHz waterproof probe

Elite 200 - Rechargeable

Digital, non-rechargeable3MHz or 2MHz waterproof probe

Elite 200

Non-digital,rechargeable

3MHz or 2MHz waterproof probe

Elite 100 - Rechargeable

Non-digital,non-rechargeable

3MHz or 2MHz waterproof probe

Elite 100

OBSTETRIC

Page 55: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 179

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Vascular Doppler Systems

Elite 100 & 200 - Configurable Pocket Doppler The Elite is a configurable pocket sized ultrasound Doppler used to determine vascular viability. Available in a variety of configurations.

Elite 100 Basic - Non-digital, non-rechargeable

EN50 Elite 100 with 5 MHz probe EN80 Elite 100 with 8 MHz probe EN58 Elite 100 with 5 MHz and 8 MHz probes

Elite 100 Basic- Non-Digital, rechargeable

EN50R Elite 100R with 5 MHz probe EN80R Elite 100R with 8 MHz probe EN58R Elite 100R with 5 MHz and 8 MHz probes

Elite 200 - Digital, non-rechargeable

ED50 Elite 200 with 5 MHz probe ED80 Elite 200 with 8 MHz probe ED58 Elite 200 with 5 MHz and 8 MHz probes

Elite 200 - Digital, rechargeable

ED50R Elite 200R with 5 MHz probe ED80R Elite 200R with 8 MHz probe ED58R Elite 200R with 5 MHz and 8 MHz probes

NOTE: The above units can be ordered with a combination of Vascular AND Obstetric Probes

Elite Probes

VASCULAR N500 Vascular 5MHz Probe N800 Vascular 8MHz Probe

OBSTETRIC

N200 Obstetric 2MHz Probe NW20 Obstetric Waterproof 2MHz Probe N300 Obstetric 3MHz Probe

Elite Accessories:

DS-1577 Rollstand with Anti-theft Mounting Bracket, Stainless Steel Construction, Weighted 5 Leg Base, 50mm Twin Nylon Castors, 25mm Diameter Pole, Nylon Coated Basket and Clamp & Anti-Theft Bracket

VASCULAR

DS-1577Elite Rollstand with Anti-

theft Mounting Bracket

& Storage Basket

(Doppler Not Included)

Elite Rollstand

Elite 200 with 8MHz probe

Digital, rechargeable5, 8 or 5 & 8MHz probes

Elite 200 - Rechargeable

Digital, non-rechargeable5, 8 or 5 & 8MHz probes

Elite 200

Non-digital,rechargeable

5, 8 or 5 & 8MHz probes

Elite 100 - Rechargeable

Non-digital,non-rechargeable

5, 8 or 5 & 8MHz probes

Elite 100

Page 56: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

INFANT CARE & MATERNITY

Page 180

Parker Healthcare Pty Ltd - Australia | Ph: +61 3 9872 0222 Fax: +61 3 9873 5911 | email: [email protected] | www.parkerhealth.com.au

Parker Healthcare Sdn Bhd - Malaysia | Ph: +60 3 6243 5848 Fax: +60 3 6242 7625 | email: [email protected] | www.parkerhealth.com.my

Parker Healthcare NZ Ltd - New Zealand | Ph: +64 9 415 8542 Fax: +64 9 415 9672 | email: [email protected] | www.parkerhealth.co.nz

INFA

NT

CA

RE

& M

AT

ER

NIT

Y

Model 100B Foetal Doppler

Features: Lightweight & Portable Large LCD Display with Blue Backlight Built-in Loud Speaker - Loud & Clear Sound Support 2MHz, 2.5MHz & 3MHz Probe Monitor 12 weeks+ Foetal Heart Rate

JPD-100B Foetal Doppler

Obstetric Dopplers and Accessories

Ultrasound Transmission Gel

Does Not Irritate Skin Non-greasy Does Not Damage Transducers External Use Only

MN.3.03.0000.10 Ultrasound Transmission Gel (250ml)

Ankle / Brachial Index (ABI) Cuff Kits

The ABI kits available as options for selected Elite 100 and Elite 200 pocket dopplers.

Please note the ABI kit must be ordered at the time of purchase of the pocket doppler.

Features: Selection of four quick disconnect vascular cuffs Sphygmomanometer Training CD presentation Reference Guide Report forms and vascular history questionnaire with ABI Chart.

ED8A Elite 200 Pocket Doppler with 8Mhz Probe and ABI KitEN5A Elite 100 Pocket Doppler with 5Mhz Probe and ABI KitEN8A Elite 100 Pocket Doppler with 8Mhz Probe and ABI Kit

Page 57: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

Index

INDEX

A

Accessories - Blenders 109Accessories - Resuscitator 106Accessories - Trolley 212Adaptors - 3 Way 122Adaptors / Connectors - Disposable 7-21Adaptors / Connectors - Polycarbonate - Semi Reusable 22-23Adaptors / Connectors - Polysulfone - Reusable 24-25Adaptors / Connectors - Reusable 26-27Adaptors, CPAP 171ADU Connector 17Aerosol Therapy Mask 94-95Air / Oxygen Blenders - Maxtec 110Air / Oxygen Blenders - Sechrist 109Air / Oxygen Mixer - Mini 113Air 3 Way Adaptor 122Air Blender - Maxtec 110Air Compressor Filter 200Air Cushion Masks - MRI 55Air Cushion Masks - Scented 56Air Cushion Masks (with Valve) 54Air Flowmeters (Floating Ball) 115Air Flowmeter Nipples 123Air Flowmeters (Click style) 116Air Hoses 123Air Incu i Incubator (Atom) 129Air Nipple 20Air Regulators 116Airway Bi-nasal Pharyngeal 165Airway Trolley 212Airways - Guedel 108Ambulance Transport Patient Monitor 183Anaesthetic Breathing Circuits 30-47Anaesthetic Cart 207Anaesthetic Circuits - Bilumen 41Anaesthetic Circuits - Coaxial 38-40Anaesthetic Circuit - Disposable - Adult 34-35Anaesthetic Circuit - Disposable - Paediatric 36 Anaesthetic Circuit - Disposable (Adult) 30-31, 34-35, 37Anaesthetic Circuit - Disposable (Paediatric) 32-33, 36Anaesthetic Circuits - Smooth Bore - Adult 37Anaesthetic Trolley 211Anaesthesia Gas Sampling Line 90Analgesia / Entonox / Mid-O-Gas Circuits 45-47, 175-177Analgesia, Equinox Advantage 173Analgesic Administration System - Entonox 122Analyser Oxygen 110,112-113Analyser Spare Parts - Maxtec 114Analysers Oxygen - Maxtec 113Aneroid Sphygmomanometer - Wall Model 191Ankle / Brachial Index (ABI) Cuff Kits 180Apnoea Monitor 150, 188Arm Table 213Armboards 156-158Aspirator - Meconium 160Atom Accessories 131-134Atom Bilitherapy, LED (Pad Type) 142Atom Incu I Tester 132Atom Incubator Accessories 133Atom Incubator and Warmer - Dual Incu i 127Atom Incubator and Warmer Optional Accessories 131-134, 145-146Atom Incubator Filters 146Atom Infalite 132Atom Infant Incubator - Incu i 128Atom Infant Incubator - Air Incu i 129Atom Infant Warmer i - Model 103 130Atom IV Pole 133Atom LED Bilitherapy Unit 141Atom Neocot Bassinet - High / Low Stand 139Atom Resusciflow Blender Resusci Flow 140Atom Resusciflow Unit Resusci Flow 140Atom Stethoscopes 172Atom Sunflower Warmer - Optional Accessories 137-138Atom Sunflower Warmer, Fixed Height 136Atom Sunflower Warmer, High / Low Tilt 135Atom Syringe Pump 147

Atom UPS - Atom Power Pack 131Atom Weight Monitor 131Atom, Test Lung 169Atom, V808 Transport Incubator 143-144Autoclave SciCan G4 196Autoclave Statim 2000S 197Autoclave Statim 5000S 198Autoclave Statim 7000 (Plus Accessories) 199Autopress Infuser 80

B Baby Control Monitor, SISS Apnoea 150, 188Babies Bath 222Bacterial Filters 29Bag - Infusion 79 Bag - Reservoir 107Bags - Rebreathing 48 Basket - Atom 134Basket Removable, Trolley 215Bassinet - Atom - High/Low Stand 139Bassinet - Trolley (Single / Twin) 222Battery UPS - Atom 131Battery - Laryngoscope Handles 69Bed Cradle 216Bidibots Nappies 168Biegler Blood and Infusion Warmer 77 Biegler Extension Set 78Biegler Tubeflow Assembly 77Bilirubin Meter 150Bilitherapy LED (Pad Type) 142Bilitherapy, Spot Type 141Bilumen Anaesthetic Circuits 41 Bilumen Breathing Circuits 41 Bin - Rubbish Trolley 215Bi-nasal Pharyngeal Airways / Duotube 165Biological Filters 201Bipap Circuit 92 Blades - Laryngoscope - Disposable Stainless Steel 60-62Blades - Laryngoscope - Reusable (Adjustable Tip) 65 Blades - Laryngoscope - Reusable 63-64Blanket - Neonatal Warming Blanket 149Blanket Warming Systems 81Blender - Air / Oxygen 109-111Blender Buddy 110Blender Spare Parts - Maxtec 114Blenders - Air / Oxygen - Maxtec 111Blood Collection Chair 219Blood Warmer - Pressure Infuser 80 Blood Warmer 77,79Blow Off Valve Connectors 19Bodok Seals 123Bottle Holder - Urinal 219Bottle Nebuliser 95Bottle Trolley 218Bougie Introducers 76 Breathing Circuit - Bipap 92 Breathing Circuit - Infant, T-Piece Resuscitation 154-155Breathing Circuits - Adult 30-31,34-35,37-42,46Breathing Circuits - Coaxial 38-40Breathing Circuits - Entonox / Mid-O-Gas 45-47, 175-177Breathing Circuits - Infant - T Piece Resuscitation 152-154Breathing Circuits - Paediatric 32-33,36,38-42,46Breathing Circuits - Resuscitation 42-44Breathing Circuits - Smooth Bore - Adult 37 Bubble Tubing - Oxygen 86 Bulbs - Laryngoscope 69 Bulk Collection Trolley 218

C

Cable ties - Secur-A-Tag 204Cannula - Diagnostic 86Cannula - Sampling 87 Cannula and Tubing Holder 163Cannula Ram Neonatal Cannulas with soft curved prongs 167

Page 58: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

Index

INDEX

C (cont.)

Cap (Plastic) 21 Capnography - Mask 88-89Cart - Anaesthetic 207Cart - Emergency 208Cart - List 214Cart - Storage 213Cassettes and Spares 201-203Catheter and Tubing Holder 163Catheter Mounts - Disposable 7-9 Catheter Mounts - Reusable 10-11Catheter Mounts - Reusable Smooth Bore 10-11Catheter Mounts with filter 9 Central Suction Attachments 118Chair - Blood Collection 219Chairs - Shower 227Chemical Indicators to suit Sterilisers 203Chinstrap - Neonatal 164Circuit - Anaesthetic Disposable (Adult) 30-31,34-35Circuit - Anaesthetic Disposable (Paediatric) 32-33,36,38, 40-42,44,46Circuit Clip Connectors 20 Circuits - Bipap 92Circuits - Anaesthetic Disposable Adult 34-35Circuits - Anaesthetic Disposable Paediatric 36 Circuits - Anaesthetic Smooth Bore - Adult 37 Circuits - Coaxial 38-40Circuits - Equinox Advantage 46-47Circuits - Mid-O-Gas 45-47Circuits - Mid-O-Gas 175-177Circuits - Q-Limb Breathing Circuits 41 Circuits - TB2000/TB3000/TB4500 Resuscitation 153Circuits - Resuscitation 154-155Circuits - Resuscitation Disposable 42-44Cirri CPAP Masks 100Clamps / Cutters (Umbilical) 158Clearing Trolley 217CO2 Nasal Cannula 87 CO2 Sampling Line All Purpose 90 CO2 Sampe Lines 89 Coaxial Breathing Circuits 38-40Comfo Vented Masks 99 Connectors - Disposable 12-13,15-21Connectors - Reusable 26-27Connectors - Polycarbonate - Semi Reusable 22-23Connectors - Polysulfone - Reusable 24-25Conserving Flow meter 117Conserving Regulator 117Corrugated Tubing - Disposable 49 Couch - Examination 223Cover - SPOFlow Meter Probe 158CPAP Adaptors 171CPAP Cannula, Ram Cannula 167CPAP Kit 170CPAP Masks - Non vented 101-102CPAP Masks - Vented 99-100CPAP Masks 99-102 CPAP Neoseal 160CPR Resuscitator 108Cradle - Bed 216Cuff and Bladder Sets 192Cuffs 52Cutters - Umbilical 158Cylinder Rack 134Cylinder Keys and Spanner 123Cylinder Trolleys 218

D

Demand Valve Resuscitator 124Demand Valve Resuscitator Spare Parts 124Diagnostic Cannula 86 Diaphragm Valve 124Diluter - Adjustable Venturi 97 Distilled Water 200

Diverter - Peep Valve 106Dividers 230Donut Shaped Silicone Masks 53 Doppler, Obstetric, Vascular 178-180Draw for Atom Incubator 133Dressing / Instrument Trolley 209Dual Incu I Incubator / Resus Warmer (Atom) 127DuoFlow - Oxygen / CO2 Nasal Cannula 87 DuoFlow - Oxygen / CO2 Sampling Cannula 88 Duoscope 57 Duotube Bi-nasal Pharyngeal Airways 165

E

Ear Thermometer - Infrared 187EASE CPAP Mask 101Easy Dial Regulator / Flowmeter 117ECG Monitor 183-185ECG Prewired Neonatal Electrodes 161-162ECG Pre-gelled Neonatal Electrodes 169Electrode - Neonatal, prewired 161-162Electrode - Neonatal, pre-wired 169Emergency Cart 208Emergency CO2 Nasal Cannula 88 Emergency Laryngoscope - Duoscope 57 Emergency Laryngoscope - Onescope 58 Emergency Transport Warmer 80 Emergency Trolley 210-211Endotracheal Tubes 73-76 Endotracheal Tube Preformed 74-75Endotrachael Tube Reinforced 76Entonox Analgesic Administration System 122Entonox Breathing Circuits 45-47, 175-177Entonox Regulators 116Equinox Advantage Analgesia Circuits 46-47Equinox Advantage Analgesia Dispenser Unit 173ET Tube Holder - Neotech 161Examination Couch 223Examination Light / Stand 226Expandable Tubing - Disposable 50 Expiratory Valve 27Extension Set 78 Eye Shades - Phototherapy 159EZCARE Disposable Trachostomy Tube Holder 166EZCARE Tracheostomy Tube Holder 166EZ-Hold Tubing and Cannula Holder 163

F

Face Tent Mask 97 Fibreoptic Laryngoscope Blades - Disposable 60-62 Fibreoptic Laryngoscope Handles 66 Files - Trolley 214Filter - Air Compressor 200Filter - HEPA 28Filter - HME 28Filter - Suction Attachments 120Filter - Twin-O-Vac 121, 123Filter to suit Statim 2000 and 5000 Series 201Filter with Catheter mount 9Filters - Bacterial / Viral 29 Filters - Respiratory 28-29Filters to suit Atom Incubators 146Finger Pulse Oximeter 187Flowmeter / Regulator 117Flowmeter - High Flow 115Flowmeter - Low Flow 115Flowmeter Conserving 117Flowmeter Nipples - Air / Oxygen 123Flowmeter Nipples 20 Flowmeters - Oxygen 115-116Flowmeters (Click Style) - Air Flow 116Flowmeters (Click Style) - High Flow 116Flowmeters (Click Style) - Low Flow 116Flowmeters (Click Style) - Oxygen Flow 116Flowmeters - Air 115-116

Page 59: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

Index

INDEX

J

Jar - Twin-O-Vac 121Jaundice Meter 150, 188Joiner Tube Connector 17

K Kessell Disposable Laryngoscope Blades 61 Key Wheel Cylinder 123Kick Bucket 215Kimguard Drying Rack 214

L

Laryngeal Masks - Disposable 71 Laryngeal Masks - Reusable 72 Laryngoscope - Disposable 62 Laryngoscope - Duoscope 57 Laryngoscope - Handles - Disposable - LED 67 Laryngoscope - Handles - Reusable - LED 67 Laryngoscope - Handles - Reusable 66 Laryngoscope - Onescope 58 Laryngoscope - Reusable (Adjustable Tip) Blade 65 Laryngoscope - Reusable Blades 63-64 Laryngoscope - Video 59 Laryngoscope - Zoom Charging Unit 69 Laryngoscope Blades - Disposable - Stainless Steel 60-61Laryngoscope Blades and Handle Kit 68 Laryngoscope Bulbs 69Laryngoscope Rechargable Batteries 69 Laryngoscope Spare Parts 70 Laryngoscopes - Handles - Disposable - LED/Conventional 68 LED - Bilitherapy Phototherapy (Pad Type) 142LED - Bilitherapy Phototherapy (Spot Type) - Atom 141LED - Neonatal Phototherapy Unit 148 LED Examination Light 226LED Examination Light for (Atom Infalite) 132LED Laryngoscope Handles 67 Light Stand 226Linen Skip Trolleys (Single, Double, Triple) 226Linkette Tube Connectors 17 List Cart 214Lithotomy Table 213Little Sucker Oral Nasal Suction Device 167Low Flowmeters 115Lung Test Lung 48

M Macintosh Disposable Laryngoscope Blades 60-62Macintosh Reusable Laryngoscope Blades 63 Magill Forceps 70 Manometer Gauge 27 Manual and Reusable Resuscitator 105Manual Disposable Resuscitator 103-104Masimo Sp02 Sensors 169Masks - Capnography 88-89 Mask Elbow Connectors 16-17 Masks - Aerosol Therapy 94-95Masks - Air Cushion - Diposable - MRI 55 Masks - Air Cushion - Disposable 54 Masks - Anaesthesia - Disposable 54 Masks - Anaesthesia 53 Masks - CPAP - Full Face and Nasal 99-102Masks - CPAP Non Vented 101Masks - CPAP Non Vented - Reusable 101-102Masks - CPAP Vented 99-100Masks - Cushion 53 Masks - Cushion Twin Port 98 Masks - Elongated - Oxygen Therapy 93-94 Masks - Face Tent 97 Masks - Headstraps 102Masks - Oxygen Therapy 93-94 Masks - PVC 53

F (cont.)

Flowmeters - Perflow High Precision 116Fluid Warmer 77 Foetal Doppler 178, 180Forceps - Magill 70

G

Garbage Trolley, Foot Operated 218Garment Rack 215Gas - Evac Nitrous Oxide Scavenge Device 174Gas Cylinder Trolley 218Gauge - Air 116Gauge - Air, Oxygen, Suction 123Gauge - Manometers 27, 123 Gauge Oxygen 116Gel, Ultrasound Transmission 180Guedel Airways 108

H

Hand Resuscitator Devices 103-105Handheld Pulse Oximeter 187Handheld SpO2 / HR Monitor 187Handi Disposable Oxygen Analyser and Sensor 112Handles - Laryngoscope 66-68Handles - Laryngoscopes - Disposable 67-68 Handles - Laryngoscopes - Reusable 66-67Handpiece - Yankauer 91Handwheel kits - Air, Oxygen, Nitrius Oxide 123Headgear Strap 98 Headstrap 102Headstrap Neoshades 159Heating Bag 79 High Concentration Oxygen Therapy Masks 93-94HEPA Filter 28HME /HMEF Filter 28 Hold-A-Line 163Hooks - Mask 53 Hose Assembly 123Hose Assembly - Oxygen, Air, Nitrus Oxide 124Hydrocolloid Strips 164

I

Imprest Trolley 220Incu I Tester 132Incubator - Warmer - Testing Device 132Incubator - Atom Air Incu-i, Model 62062 129Incubator - Atom Dual Incu i, Model 100 127Incubator - Atom Incu i, Model 101 128Incubator Filters - Atom 146Incubator Transport V808 143-144Indicators - Chemical to suit Sterilisers 203Infa Warmer I - Model 103 130Infalite - Atom 132Infant Resuscitation Circuits 152-155Infant Resuscitation Device Atom 140Infant Resuscitator 151Infrared Ear / Forehead Thermometers 186-187Infusor - Automatic Pressure 80 Infusion Warmer 79 Instrument Trolley 209,224-225Intubation Stylettes 76 I-Puff Infant Resuscitation Circuit 154IV Armboard 156-158IV Extension Sets 78 IV Fluid Warmer 77 IV Pole Atom 133IV Poles 221IV Set-up Trolley 211

Page 60: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

Index

INDEX

M (cont.)

Masks - Resuscitation 53-54Masks - Silicone Donut Reusable 53 Masks - Silicone Headstrap 98 Masks - Strawberry Scented 56 Masks - Tracheostomy 96 Masks - Venturi 97 Masks Laryngeal Disposable 71 Masks Laryngeal Reusable 72 Mattress Atom 134Mattress Neonatal Warming 149Mattress Warming Systems 81 Maxtec Air / Oxygen Blenders 110Maxtec Analyser and Blender Accessories 114Mayo Table 213MDI Adapters 14 Meconium Aspirator 160Medication Trolley 212Meter - Jaundice 150, 188Micro NeoLead 162Mid-O-Gas Circuit 45-47, 175-177Miller Disposable Laryngoscope Blades 60,62Miller Reusable Laryngoscope Blades 63Mini Air / Oxygen Mixer 113 Mixer - Air / Oxygen Maxtec 110-111Mixer - Air / Oxygen Sechrist 109Mixer - Oxygen Maxtec 113Mobile Storage Unit 229Mobile Warmer - Atom 136Modular Equipment Trolley 214Moist Laundry Trolley 220Monitor - Infant Resuscitator 151Monitor - Jaundice 150, 188Monitor - Neonatal 184Monitor - Obstetric 185Monitor - Oxygen 112Monitor - Oxygen Maxtec 113Monitor - SISS Apnoea 150, 188Monitor - Video Otoscope 189-190Monitor - Vital Signs 183Monitor - Weight - for Atom Warmer 131Monitor Video Otoscope (Vet) 190Monitors - Sp02 - Finger / Handheld 187Mouthpiece - Sampling Cannula 88 Mouthpieces 13MRI - Anaesthetic Circuit - Adult 31MRI - Armboards 157-158MRI - Masks - Air Cushion 55 Multi Drawer Trolley 212

N

Nappies, Neonatal (small, medium and large) 168Nasal Cannula - CO2 88 Nasal Cannula - Oxygen / CO2 87 Nasal Cannula 85 Nasal CPAP Kit 170Nasal Endotracheal Tubes 73-74, 76Nasal Suction Device 167Nebuliser Bottle 95 Nebuliser Kit 95 Nellcor Sp02 Sensors 169Neobar, ET Tube Holder 161Neobond Medical Grade Hydrocolloid Strips 164Neobridge - Umbilical Catheter Holder 163Neocot - Atom (Accessories) 139Neogrip Multipurpose Tubing and Cable Holder 162Neoguard, Resuscitator 151Neolead 162Neolead, ECG Electrodes 161Neonatal - ECG electrodes 169Neonatal Blanket, Warming 149Neonatal Chin Strap 164Neonatal Phototherapy Unit 148Neopulse Pulse Oximeter Wrap 165

Neoseal - CPAP Nasal Prong Seal 160Neoshades Phototherapy Eye Shades 159Neosmile Temperature Probe Cover 164Neospoon measuring spoon 165Neotech Chin Strap 164Neotech EZ-Hold 163Neotech Hold-A-Line 163Neotech Meconium Aspirator 160Neotech Micro Neolead 162Neotech NeoBar 161Neotech NeoBond 164Neotech NeoBridge 163Neotech NeoLead 161Neotech NeoPulse 165Neotech NeoSeal 160Neotech NeoSmile 164Neotech Neospoon 165Neotech Snorkel 160Neotech Suction Caddy 160Nipple Shields - Silicone 169Nipples - Air / Oxygen 123Nipples (Oxygen / Air) 20 Nipples for Oxygen and Air Flowmeters 123Nitrius Oxide Hoses 123Nitrous Oxide Scavenge Device 174Nitrous Oxide/Oxygen Mixer 173Nitrous Oxide 3 Way Adaptors 122Non Vented Masks - Cpap 101Non-Contact Thermometer 186-187Norman Mask Elbow 16 Norman Mask Elbow Connector 26

O O Series Regulators 116Obstetrics Doppler 178Onescope 58 Oral Suction Device 167Oral Endotracheal Tubes 73, 75-76Otoscope (Video) 189Otoscope 70 Otoscope Video, Veterinary 190Oxgen Regulators 116Oxygen - Suction Device 121Oxygen / Air Blender Sechrist 109Oxygen / Air Blenders Maxtec 110Oxygen / CO2 Mask 88-89Oxygen 3 Way Adaptor 122Oxygen Analyser 110,112Oxygen Analyser - Maxtec 113Oxygen Bottle Trolley 218Oxygen CO2 Nasal Cannulas 87 Oxygen Conserving Flowmeter 117Oxygen Flowmeters (Floating Ball) 115Oxygen Flowmeter 115Oxygen Flowmeter (Click Style) 116Oxygen Flowmeter Nipples 123Oxygen Hose Assembly 124Oxygen Hoses 123Oxygen Mixer - Maxtec 113Oxygen Nasal Cannula 85 Oxygen Nipples 20 Oxygen Regulator - Conserving 117Oxygen Sensor - Atom Incubators 145Oxygen Therapy 95 Oxygen Therapy Mask 93-94Oxygen Tubing 155Oxygen Tubing - Star Lumen 86 Oxy-Viva3 Resuscitator 124

P

Paediatric Y Piece Connector 13Pan and Bottle Rack 219Paper - Thermal 200Patient Monitors 183

Page 61: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

Index

INDEX

P (cont.)

Patient Trolley (Fixed Height) 223Peep Connectors 18Peep valve 106Perflow Flowmeters (Click Style) 116Personal Distribution Trolley 219Phototherapy - Atom 141Phototherapy - LED 148Phototherapy - Pad Type - Atom 142Phototherapy Eye Shades 159Plastic Cap 21Pocket CPR Resuscitator 108Power Pack - Atom 131Power Control Unit - Mattress and Blanket 81Preparation Table 216Pressure Feedback Line Filter 29Pressure Infuser 80 Printer to suit 2000S Autoclave 203Printer to suit Series Statim 2000S 197Printer to suit Statim 5000 Series 200Privacy Screen 225Probe Cover SpO2 (Neonatal) 158Probe Temperature Cover 164Process Challenge Device 203Protherm II Blood and Infusion Warmer 79Pulse Oximeter 187Pulse Oximeter Wrap - NeoPulse 165Pump, Syringe - Atom 147

Q

Q-Limb Breathing Circuit 41

R

Rack - Garment 215Rack - Pan and Bottle 219Ram cannula Neonatal Cannulas with soft curved prongs 167Rebreathing Bags 48 Rechargable Laryngoscope Handle Charging Station 69Regulator - Oxygen Conserving 117Regulator / Flowmeter 117Regulators - Air 116Regulators - Entonox 116Regulators - Nitrous Oxide 116Regulators - O Series 116Regulators - Oxygen 116Regulators Suction 119Reservoir Bag 107Respiratory Filters 28-29Resusciflow Blender Atom 140Resuscitation Circuits 42-44, 152-155Resuscitation Trolley 210Resuscitation Warmer - Atom 130Resuscitation Warmer - Atom Sunflower 135Resuscitator - Accessories 106Resuscitator - CPR 108Resuscitator - Manual Disposable 104Resuscitator - Oxy-Viva 3 124Resuscitator - Manual Disposable 103Resuscitator - Manual Reusable 105Resuscitator - Neoguard 151Resusiflow Blender - Atom 140 Resusiflow Unit - Atom 140Resuscitator Valve 107Rubbish Bin Trolley 215

S

Sample Lines 89Sampling Cannula 87 Sampling Line All Purpose 90 Scavange Adaptor 118Scavange Attachment 118

Scavange Connector 15Scavenge Device - Nitrous Oxide 174 Scented Masks 56 Screen - Privacy 225Seals - Bodok 123Sechrist Air/Oxgen Blenders 109Secur-A-Tag Security Tags 204Showe Chairs 227Silicone Masks 53 Silicone Nipple Shields 169Skin Probe Cover 164Skin Temperature Probe - Atom 145Smooth-Bor Tubing Reusable 52 Smooth-Bore Tubing Disposable 51 Smooth-Bore Catheter Mounts - Reusable 10-11SmoothFlow - Oxygen Nasal Cannula 85 SmoothFlow - PVC Tubing 86 SmoothFlow Sampling Cannula 87 Snorkel - Suction Device 160Softi Nasal Cannula 85 Soiled Linen Trolley 220SpO2 Monitors 187SpO2 Probe Cover / Wrap 165SpO2 Sensors (Masimo, Nellcor) 169Spare Parts - Laryngoscope 70 Spare Parts - Oxygen Analyser and Blender 114Sphygmomanometer - Spare Parts 192Sphygmomanometer (with trolley and basket) 191Spigots 20Split (Armboards) 156-158SpO2 Probe Cover 158Spoon - Measuring Spoon 165Standard/Conventional Laryngoscope Blades 62 Standard/Conventional Laryngoscope Handles 66 Stat-Dri for Statim Cassettes 201Step Stools 216Sterilisation - SciCan G4 196Sterilisation - Statim 2000S (and spares) 197Sterilisation - Statim 5000S 198Sterilisation - Statim 7000 (Plus Accessories) 199Steriliser Cassettes and Spares 200-203Stethoscopes - Atom, premature/Newborn 172Stethoscopes (Animal) 172Stool - One Step / Two Steps 224Stool - Surgeon 224Stools - Step 216Stools - Surgeon 217Storage Cart 213Storage Case for Resuscitators 107Storage Unit 229Strap - Silicone Headstrap 98 Strawberry Scented Masks 56 Stylettes 76 Suction 3 Way Adaptors 122Suction Attachments 118Suction Caddy Neotech 160Suction Connection Tubing 91 Suction Device - Little Sucker 167Suction Device - Multipurpose Neotech 160Suction Filter 120Suction Filter Housing 120Suction Filter Kits 120Suction Jar 121Suction Port Adapters 21Suction Regulators 119Suction Twin-O-Vac 121Sunflex Laryngoscope Blades with Adjustable Tip 61,65Sunflower Warmer - Atom, High / Low 135Sunflower Warmer - Cabinet / Tilt 136Sunflower warmer - Wallmount 135Surgeon Stools 217Swaddling Blanket, Neonatal 149Swivel Elbow Connector with Suction Port 21Syringe Pump, Atom 147

Page 62: INFANT CARE & MATERNITY - Parker Healthcare …...Works with ALL BRANDS of Incubators and Infant Warmers 61639 Incu i Tester Includes: Special disk sensor for measurement of the radiation

Index

INDEX

T

T Piece Connector 13-14Table - Arm 213Table - Lithotomy Table 213Table - Mayo 213Table - Preparation 216T-Adaptors 3 Way 122Teeth Opener 98 Temperature Probe - SKIN - Atom 145Test Lung 48Test Lung - 50ml 169Tester - Incu i 132Thermal Printer Paper 200Thermometer (VisioFocus, Thermofocus, PM2000) 186-187T-Piece Infant Resuscitation Circuits 152-153Tracheostomy HME 28Tracheostomy Masks 96 Trachostomy Tube Holder Disposable 166Trachostomy Tube Holder EZCARE 166Transport Incubator V808 - Atom 143-144Transport Monitor - C30 183Transportation Trolley 214Tray - Light-Weight 216Tray Set Atom 134Tray System 230Trolley - Accessories 212Trolley - Airway 212Trolley - Anaesthetic 207Trolley - Anaesthetic 211Trolley - Basket Storage 228-229Trolley - Bassinet (Single / Twin) 222Trolley - Bulk Collection 218Trolley - Clearing 217Trolley - Dressing Instrument 209Trolley - Emergency 208,210-211Trolley - Files 214Trolley - Foot Operated - Garbage 218Trolley - Garment Rack 215Trolley - Gas Cylinder 218Trolley - Hi/Low Mortuary Concealment 223Trolley - Imprest 220Trolley - Instrument 224,225Trolley - IV Poles 221Trolley - IV Set-up 211Trolley - IV Set-up and emergency 210Trolley - Kick Bucket 215Trolley - Light-Weight Tray 216Trolley - Linen Skips (Single, Double, Triple) 226Trolley - List cart 214 Trolley - Lithotomy Table 213Trolley - Mayo table 213Trolley - Medication 212Trolley - Modular Equipment 214Trolley - Moist Laundry 220Trolley - Multi Drawer 212Trolley - Oxygen Bottle 218Trolley - Patient Fixed Height 223Trolley - Personal Distribution 219Trolley - Preparation Table 216Trolley - Removable Basket 215Trolley - Resuscitation 210Trolley - Rubbish Bin 215Trolley - Shower Chairs 227Trolley - Soiled Linen 220Trolley - Storage Cart 213Trolley - Transportation 214Trolley - Tub 225Trolley - Wet and Dry Laundry 220Tub Trolley 225Tube Holder ET 161Tubes - Endotracheal Reinforced 76 Tubes - Endotracheal 73-75Tubing - Bubble Tubing 86 Tubing - CO2 Sampling Line 89-90Tubing - Disposable Corrugated 49 49-50Tubing - Fluid Infusion 78

Tubing - Oxygen Nasal 85 Tubing - Smooth Bor - Reusable 52 Tubing - Smooth Bore - Disposable 51 Tubing - Suction Connection Tubing 91 Tubing and Cable Holder 162Tubing and Cannula Holder 163Tubing Corrugated 30M (Natural, Pink, Blue) 171Tubing Holder 163Tubing Oxygen 155Twin-O-Vac High Vacuum 121Twin-O-Vac Filter 123Twin-O-Vac Low Vacuum 121Tympanic Thermometer 187

U

Ultrasound Transmission Gel 180Umbilical Catheter Holder 163Umbilical Clamp Cutters 158Umbilical Clamps 158UPS - Power Supply - Atom 131Urinal Bottle Holder 219

V

V808 Transport Incubator - Atom 143-144Vacusill Regulator 119Vacusill Spare Parts 119Vacuum Attachments 118Valve - Diaphragm 124Valve - Peep 106Valves 107Vascular Doppler 179Vented Face Masks - CPAP 99Vented Masks 100Ventilation Circuits - Adult 35Ventilation Circuits - Paediatric 36 Venturi Adjustable Diluter 97 Venturi Mask 97 Venturi Suction Attachments 118Video Laryngoscope 59 Video Otoscope 189Video Otoscope (Veterinary) 190Viral Filters 29

W

Wallmount Warmer - Atom 135Warmer - Atom Sunflower 136Warmer - Blood / Fluid 77 Warmer - Blood / Fluid 79 Warmer - Emergency Transport 80Warmer - Incubator - Atom 127Warmer - Infant Warmer - Atom 130Warmer - Sunflower Atom 135Warming Blanket and Mattress 149Warming Systems - Mattress and Blanket 81 Washington T Piece 16 Washington T Piece Connector 26 Water - Distilled 200Weight Monitor Unit for Atom Infa Warmer i 131Wet and Dry laundry Trolley 220Wingnuts for Oxygen / Air 123

Y

Y-Adaptor 3 Way 122Yankauer Hand Piece 91 Y-Piece Connector 12Y-Piece Connector (Polycarbonate - Semi Reusable) 22-23Y-Piece Connector (Polysulfone - Reusable) 24-25

Z

Zoom - Laryngoscope Handle Charging Station 69