Influence of Heat Treatment on Photodesorption of Copper Plated SSCL Beam Tube A progress report presented to Dr. William C. Turner at the Superconducting Super Collider Laboratory by Baoping He Michael Stawovy Guo-Quan Lu Seshu B. Desu William T. Reynolds Alex 0. Aning Virginia Polytechnic Institute and State University Blacksburg, Virginia February 25, 1994

Upload: others

Post on 01-Sep-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Influence ofHeat Treatment on Photodesorption of Copper Plated …lss.fnal.gov/archive/other/ssc/ssc-n-849.pdf · 2006. 8. 23. · 4.1% in the annealed sample. The average grain size

Influence of Heat Treatment on PhotodesorptionofCopper Plated SSCL Beam Tube

A progressreport

presentedto

Dr. William C. Turner

at the SuperconductingSuperCollider Laboratory

by

BaopingHeMichael Stawovy

Guo-QuanLuSeshuB. Desu

William T. ReynoldsAlex 0. Aning

Virginia PolytechnicInstituteandStateUniversity

Blacksburg,Virginia

February25, 1994

Page 2: Influence ofHeat Treatment on Photodesorption of Copper Plated …lss.fnal.gov/archive/other/ssc/ssc-n-849.pdf · 2006. 8. 23. · 4.1% in the annealed sample. The average grain size

Accomplishments

* Influenceof heattreatmentprocedureon the microstructureof copperlayerin the SSCLbeamtubehasbeeninvestigatedby SEM andX-ray di&action.

* A one-meterlong tube with electrodepositedCu film was heat treatedat 700°C for 2

hourswith a moving stagefUrnaceandwasdeliveredto SSCLon August 6. This sample

tubewill be referredto astube#008vafterward;

* A one-meterlong tube with electrodepositedCu film was heat treatedat 700°C for 5hours in a larger furnaceand was deliveredto SSCL on August 23. This sampletube

will be referredto astube#007vafterward;

* Photodesorptionmeasurementsshow that the bestresultwas obtainedwith tube #007v.The photodesorptionoutgassingofH2 and CO2 werereduceda factor oftwo andCO a

factorofthreecomparedto tubeswithouttheheattreatment.

Introduction

The photon-stimulated desorption of H2, CH4, CO and CO2 gasses in the

SuperconductingSuperCoffider LaboratorySSCL beamline is detrimentalto SSCL normal

operation. Thephotodesorbedgasmolecules,particularlyhydrogen,will demolishthevacuumand scatterthebeam[1,2J. Thereareseveralapproachesto solvethis problem[31,oneof themis to reducethe amount of hydrogenin thenearsurfacematerialsofthe beamtube. For thepresentresearch,the material in concernis an electrodepositedcopper film on Nitronic 40stainlesssteeltube.

Single crystal copper has a very low hydrogen solubility[4]. However, in the

electrodepositedcopper films, there are significant amounts of copper oxides, pores,dislocationsandgrainboundarieswhich fUnction asstoragesitesfor hydrogen[5-7]. In orderto reducehydrogenand other gasesin electroplatedcopper films, one needsto 1 reduceporosityandoxide contents,2 enlargegrain sizesoasto reducethetotal grainboundary,and3 removethegasesfrom thesestoragesites. The gasesin thecopperfilm canbe removedbyheatingthematerial in vacuumor hydrogen. Hydrogenis thebestreducingelements,it reactsand reducesoxidesat an elevatedtemperature.Due to its high diffUsion rate, it can be readilyremovedfrom the copper film when the tube is later evacuated. The grain size increasesthroughrecrystallizationwhenthematerial is annealedat an elevatedtemperaturefor sufficienttime. Therecrystallizationprocessalsoreducestheporosity.

The objective of this researchis to reducephotodesorptionoutgassingof H2, CO andCO2 from the SSCL beamline throughimprovementof the microstructureand chemistry of

1

Page 3: Influence ofHeat Treatment on Photodesorption of Copper Plated …lss.fnal.gov/archive/other/ssc/ssc-n-849.pdf · 2006. 8. 23. · 4.1% in the annealed sample. The average grain size

copperfilm on the stainlesssteelbeamtube. Oneapproachto accomplishthis objective is todevelop an appropriateheat treatmentprocedurewhich would both reduce porosity andoxides,andenlargethegrain size oftheelectroplatedcopperfilm.

Experiment

A. Effect of Heat Treatmenton the Microstructure and Chemistry of SmallSamples

Onemeterlong 33mmOD sampleSSCLbeamtubeswere suppliedby SSCL. The tubeswere made of Nitronic 40 stainlesssteel SS with Silvex electrodepositedCopper films50-7Ojxmon theinnersurfaceof thetubes. Small heattreatmentsamples20x20mm were

cut from the tube. Microscopicanalysisof the copperfilm was doneusing both optical andscanning electron microscopes. Electron microscopic work was accomplishedusing anElectroScanEnvironmentalScanningElectron Microscope. The resultsof SEM analysisonthe original "as received"samplesshoweda porouscolumnartypestructureasshownin Figure1. At highermagnifications,a fine distributionofporeswasclearlyvisible in this sample. Boththe columnarstructureand porosity were a result of the electrodepositiontechniqueused ingrowing thecopperfilm.

With the properannealingprocedure,the desiredeffect would be to recrystallizethe finegrained columnar structure and grow a large grained structure, while at the same timeconsolidatethe small poresinto larger onesthatwould leadto some overall reductionof thevolume of porosity. The first step in setting the annealingconditions was finding theappropriatetemperature. A temperaturerangewas studiedfrom 600°C to 800°C at 50°Cintervals. The effectof annealingtime on themicrostructurewasalsostudiedfrom 1 hourto 5hours. The heat treatmentwas done in an atmosphereof 10% H2 + 90% He gases.Hydrogenwasintroducedto reducethe copperoxideson the "as received" tube which wereformed during electroplatingand shipment. The use of a reducingatmosphereduring theannealingprocedurebrought about some changein the chemistry of the copper film. Thechangeis noticedin thecolorof thecopperfilm from a dull, light coppercolor to adeep,dark,rich coppercolor. Although theexactnatureofthechangeis not yet known, it is believedthatthe surface oxides of the original copperfilm were reducedback to pure copper. It wasobservedthatthegrain size increaseswith increasingannealingtemperatureandtime. Figure2showstheSEM imageofa copperfilm annealedat 700°Cfor 5 hours. It can be seenthat theannealedsampleexhibitsboth of thedesiredeffects. The largegrainedstructureis seenwith aconcentrationoflargeporeson thegrainboundaries.Using alinear interceptmethod,averageporosity and averagegrain diameterwere approximatedfor the original and the annealed

2

Page 4: Influence ofHeat Treatment on Photodesorption of Copper Plated …lss.fnal.gov/archive/other/ssc/ssc-n-849.pdf · 2006. 8. 23. · 4.1% in the annealed sample. The average grain size

sample. The averageporosity decreasedfrom 22.9 ± 7.2% in the original sampleto 10.2 ±4.1% in the annealedsample. The averagegrain size increasedfrom 5.6 ± 2.5 micronsin theoriginal sampleto 20.5 ± 10.8micronsin the annealedsample.

X-ray di&action profiles of the original sampleand the annealedsamplealso show thatthe grain size and crystal perfection have been dramatically improved by the annealingtreatment. Figures3 is thex-ray diffraction profilesof 111 peakoforiginal sampleand700°C-5 hoursannealedsample. The original samplehasa broadpeak with FWHM fUll width athalfmaximumof 0.45°. Thebroaddiffitction profile is dueto the small grain size and crystal

distortion. The x-ray di&action profile of the 700°C-5 hours annealedsampleis much

shaiperwith FWHM of 0.18° so as to reveal the Kctl -Ka2 doublet. The conclusionis that

theannealedsamplehaslargergrain sizeandless defects.

B. One-Meter Long Tube Treatments

Basedon theresultsfrom small samples,we decidedto annealone-meterlong SSCLbeamtubesat 700°C. The first tube #008vwastreatedwith a 150mm-longfUrnaceon a traveling

stage. The schematicof the fUrnace setup is shown in Fig. 4. It is expectedthat thetemperatureof the copper film on the inner surfaceis lower than the outer surface. Thetemperatureof the fUrnace was controlled at 715°C. The fUrnace moving speedwas sodesignedthat it took 2 hoursfor the 150mm-longfUrnaceto passeachspotsof thetube. Topreventthe treatedcopper film from oxidation during shipping and handling, the tube waspassivatedby vapor deposition of approximately 200 to 300 angstromsof gold after theannealing. This tubewasdeliveredto SSCL on August6 for photodesorptionmeasurements.

The secondtube#007vwastreatedat 700°C for 5 hoursin a largerfUrnacewith quartz

outlet to introducethe protectiongas into the tube. Since the whole tube is treatedin thefUrnace simultaneously,we was able to choose a longer annealing time. This tube wasdeliveredto SSCL on August23 for photodesorptionmeasurements.

C. PhotodesorptionMeasurement

Photon stimulated desorptionPSD experiments were conducted on the NationalSynchrotronLight Source NSLS at BNL and on the VEPP2M storagering at BINP,Novosibirsk,Russia[8]. In additionto thetwo tubestreatedin WI #007vand#008v,othertubeseitheruntreated,or different materialsor treatedelsewhereweremeasuredin the samesetup. Theyarelisted in Table I, runs#1-#8 arefor tubeswithout heat treatmentin WI, run#9 is for tube #008v and run #10 for #007v. Sampleswere installed in the beamlineandpumpedto vacuumof l0 ton, andthenexposedto photonsand measured.Eachbeamtubesampleis exposedto approximately1023 photonswhich represents100 daysof SSCoperation.

3

Page 5: Influence ofHeat Treatment on Photodesorption of Copper Plated …lss.fnal.gov/archive/other/ssc/ssc-n-849.pdf · 2006. 8. 23. · 4.1% in the annealed sample. The average grain size

The PSD experimentresultsare shownin Table II. Photodesorptioncoefficientis definedasdesorbedgasyields in moleculeperphoton. The total amount ofphotodesorbedH2, CO

and CO2 and total photonexposurefor eachrun is also listed in the table. Among the ten

measurements,run #2 wason a purecoppertube, run #3 in a 1100gaussdipole magneticfield,

run#4 on a sampleofdifferentvendor,run #5 and #6 on asame350°Cvacuumbaked sample,

and run #7 on a 2 microns gold flushed sample. In order to evaluatethe effect of heat

treatment,we will analysisthe resultsfor run #9 and #10 and comparethem with run #1 and

#8 which areplatedCu without heattreatment.

Photodesorptioncoefficientsfor H2, CO, CO2 andCH4 versusaccumulatedphotonsfor

run #1, #8, #9 and #10 are given in Fig. 5-8. Comparedto run #1 and #8, run #9 on thesampleannealedat 700°C for 2 hourswith a moving stagefUrnacedid not show anyreduction

in photodesorption. Run #10 on the sampleheat treatedat 700°C for 5 hours in a largerfUrnaceachievedthebestresult. Comparedto run #8, thephotodesorptionoutgassingofH2

andCO2 werereduceda factoroftwo andCO a factorofthree.

Discussion

The resultsof SEM analysison the original "as received" sampleand the sampleheat

treatedat various temperaturesfor different times have given us a guideline on the heat

treatmentof the Cu plated SSCL beam tube. An annealingat 700°C for 5 hours can

recrystallizethe fine columnar grain and consolidatethe small pores. This leads to someoverall reductionof grain boundaryand porosity. X-ray diffiaction resultsconfirmedthat the

crystal structurein the heat treated sampleis much more perfect than that of the original

sample. The reducinggasalsoeliminatedoxidesin theplatedcopperfilm. Since the copper

oxides,pores,dislocationsandgrainboundariesfUnction asstoragesitesfor trappinghydrogen

and other gases,the improvementof the microstnictureand chemistry of the electroplatedcopperfilm can reducethephoton stimulateddesorption. Run#10 on a sampleheattreatedat700°C for 5 hours in a largerfUrnacehasconfirmedthis anticipation.

The first tube run #9 did not havethe expectedresults. This is probably due to thefollowing reasons:1 The heat treatmenttime is short comparedwith the secondtube run#10. The first tube washeattreatedon a travelingovenfor 2 hoursin thecontrastof 5 hours

for the secondtube. Due to the temperaturedrop at both endsof the fUrnace, the effectivetime is much less than 2 hours. 2 At both endsof the tube,no heat treatmenteffect wasexpectedsincethe flange removesheataway andthe fUrnacecan not make fUll passover thetwo ends. So that the microstructurein theboth endsof the tube is not improved. 3 Theheatup areais localizedin a 150mmrange,the gasinside thetubewill removeheat from the

4

Page 6: Influence ofHeat Treatment on Photodesorption of Copper Plated …lss.fnal.gov/archive/other/ssc/ssc-n-849.pdf · 2006. 8. 23. · 4.1% in the annealed sample. The average grain size

hot regionmorerapidly thanin the caseof the secondtubecase.We expecta more dramatictemperaturedrop inside thetube. The real temperatureof thecopperfilm is likely to be lowerthan the prescribedtemperature.4 Although we have consideredthe aboveeffects in thefirst sample treatment, the effects were under-estimateddue to lack of quantitativeinformation. Further investigationon the above effectsshould be conductedif the travelingstagefUrnaceis chosenasa practicalwayto treat theSSCLtube.

The result from run #10, thoughencourage,is only an early stepin finding an appropriateheat treatmentprocedure. Further investigationon the heat treatmenttemperatureand time,surfacecleaning beforethe treatment,content of the protectiongas, and vacuum degassingafterheattreatmentwill bring aboutmorepromisingresults. It is possibleto achievean orderof magnitudeor morereductionof photodesorption.

ConclusionsAnnealingtheSSCLbeamtubeat 700°Cfor 5 hoursin a reducinggascanreduceporosity,

surfaceoxides and grain boundaries. As a result, thephotodesorptionoutgassingof H2 andCO2 were cut downby a factor of two and CO by afactorofthree. The unsatisfactoryresult

on thesampletreatedon atravelingovenis due to insufficient annealingtemperatureandtime.More experimentsare neededto fUrther improve the microstructureand chemistry of CuplatedSSCLbeamtube.

PersonnelInvolvedFaculty -- Guo-QuanLu, SeshuB. Desu,William T. Reynolds,andAlexander0. AningPost-doctoralFellow -- Dr. Bao-PingHeGraduateStudents-- MichaelStawovy,ClaireChen,Joon-WonChoe,andJ-K. ChenUndergraduateStudents-- DavidJonesand JonathanRowley

References

1. A. Maschke, "Hydrogen desorptionand the searchfor the higgs," SSCL-Preprint86,Mar. !992.

2. Maslennikov,W. Turner, V. Anashin,Malyshev, V. Nazmov, V. Pindyurin,A. Salimov,C. Foerster, C. Lanni, "Photodesorptionexperiments on SSC Collider beam tubeconfigurations,’SSCL-Preprint378, May 1993.

3. W. Turner, "Dynamic vacuumin the beamtube of SSCL Collider-cold beam tube andliner options," SSCL-Preprint404, May 1993.

5

Page 7: Influence ofHeat Treatment on Photodesorption of Copper Plated …lss.fnal.gov/archive/other/ssc/ssc-n-849.pdf · 2006. 8. 23. · 4.1% in the annealed sample. The average grain size

4. WarnerEspe, "Materials ofHigh VacuumTechnology,"670-694,PergarnonPress,

Oxford, 1966.

5. Wert, Ch. A., "Trapping of Hydrogenin Metals", Topics in AppliedPhysics:Hydrogen

in MetalsII, Vol. 29, Springer-Verlag,Berlin, 1978, pp. 305-330.

6. Wampler,W. R., Schober,T., Lengeler,B., "PrecipitationandTrappingof Hydrogen

in Copper",Phil. Mag., 1976, Vol. 34, No. 1, 129-141.

7. Fast,J. D., InteractionsofMetalsandGases,AcademicPress,NewYork, 1965.

8. C. Foerster,C. Lanni, 1. MaslennikovandW. Turner, "Photon desorptionmeasurements

of copperandcopperplatedbeamtubesfor the SSCL20 TeV protoncollider," AVS

meeting,Orlando,FL, Nov. 15-19, 1993.

6

Page 8: Influence ofHeat Treatment on Photodesorption of Copper Plated …lss.fnal.gov/archive/other/ssc/ssc-n-849.pdf · 2006. 8. 23. · 4.1% in the annealed sample. The average grain size

TableI: Sampletubesfor photonstimulateddesorptionPSDexperiments[5]

Run Tube# Materials and Treatment Source,Year Set Up

#1 024 Cu PlatedStainlessSteel Silvex, 1988-90 Unbaked

#2 025 CopperC10100 Hitachi Unbaked

#3 030 Cu PlatedStainlessSteel Silvex, 1988-90 Unbaked,1100gausst

#4 029 Cu PlatedStainlessSteel Fluhman,1992 Unbaked

#5 032 Cu PlatedStainlessSteel Silvex, 1988-90 3 50°CVacuumBaked1?

#6 O32rot ReRun#5, Rotated140° Silvex, 1988-90 No Backfill

#7 033 Au flashedCu PlatedSS Silvex, 1993 Unbaked

#8 034 CuPlatedStainlessSteel Silvex, 1993 Unbaked

#9 008v CuPlatedSS, 700°C-2Hours

ScanningAnnealing,Au flashedSilvex, 1988-90 Unbaked

#10 007v CuPlatedSS, 700°C-5HoursAnnealing

Silvex, 1988-90 Unbaked

t Measuredin a 1100 gaussmagneticfield.Q Vacuumbakedprior to PSD exposureSSCcan notbe vacuumbaked.

TableII: Photodesorptioncoefficientsandamountof photodesorbedH2 , CO and CO2 for

different test samplesat approximate10B photons/mBNL runs

Run#Yield, Molecules/Photon GasDesorbedTorr-Liter

TotalPhotonsH2 CO CO2 H2 CO CO2

#1 1.4xlC’ 2.0x105 1.lx105 1.7 3.5xl0’ 2.4x10’ 9x1022

#2 1.0xl0 2.6x105 2.0xl05 7.9x10’ 2.3x10’ 2.5x10’ 7x1022

#3 1.4xl0 l.9xl05 l.7xl0’ 9.8xl0’ 2.3xl0’ 1.7x10’ 2xl023

#4 1.5x10 2.8x10’ l.2xl0’ 8.2xl0’ 1.8xl0’ 1.8x10’ 2x1023

#5 9.0xl05 1.2xl05 9.4x105 5.2xl0’ 8.2xl02 l.1x10’ 7x1022

#6 7.0x105 1.lx105 5.0x10’ 4.OxlO’ 6.lx102 3.1x102 1x1023

#7 l.4xl0 1.2xl05 9.5x10’ 1.0 1.3xl0’ 1.2xl0’ lx 1023

#8 1.OxlO’ 2.5x105 2.lxlO5 1.05 3.0x10’ 3.1x10’ lxlOB

#9 l.6xl0 3.Ox 1cr5 2.9x 1Cr5 1.68 4.4x10’ 5.5x ICr’ 1xl0

#10 6.8x1Cr5 1.4x105 1.6x105 4.5x10’ 8.8x1Cr2 l.6x1Cr’ lx10

7

Page 9: Influence ofHeat Treatment on Photodesorption of Copper Plated …lss.fnal.gov/archive/other/ssc/ssc-n-849.pdf · 2006. 8. 23. · 4.1% in the annealed sample. The average grain size

Figure 1Original Sample

- -‘ ,__.-

-

- .t - ..--,. -if-$t -- --- - - - -

-- -e -

--S-- e- &- -S-.- -- a -;--

-, -.

--. I - - -

.

---

5-,-- - -.

,,--‘‘r:4.

-‘-ft#’ 43 t

-‘ = -

- -4 -,-‘ --- -

-

-t

- - - ‘.,_.,,_ -s t. -Eu-Li -5L’oe -- -,--,"

]l-Jd.l4,lL -H,-IrLL‘-‘,‘‘ It’ I4.

8

Page 10: Influence ofHeat Treatment on Photodesorption of Copper Plated …lss.fnal.gov/archive/other/ssc/ssc-n-849.pdf · 2006. 8. 23. · 4.1% in the annealed sample. The average grain size

Figure 2AnnealedSample

9

Page 11: Influence ofHeat Treatment on Photodesorption of Copper Plated …lss.fnal.gov/archive/other/ssc/ssc-n-849.pdf · 2006. 8. 23. · 4.1% in the annealed sample. The average grain size

20

Figure3. X-ray di&action profiles of 111 peakof the original sampleandthe700°C-Shoursannealedsample. Theoriginal samplehasa broadpeakwith FWHM fUll width at half maximum of 0.45°. The annealedsamplehasa sharperpeakwith FWHM of 0.18° and showstheKulKa2 doublet.

>-I-i5zwI-

42 43 44 45

10

Page 12: Influence ofHeat Treatment on Photodesorption of Copper Plated …lss.fnal.gov/archive/other/ssc/ssc-n-849.pdf · 2006. 8. 23. · 4.1% in the annealed sample. The average grain size

Figure4. Schematicof thetravelingstagefUrnaceusedfor annealingSSCL tube#008v. 1-GasInlet; 2-Thermocouple; 3-SSCL Tube; 4-Flange; 5-GasfVacuumOutlet; 6-SteppingMotor; 7-Traveling Rail; 8-VacuumSensor; 9-Tube Supporter; 10-Furnace;11-ReducingGas Flow; 12-AdjustableFurnaceStage;13-Driving Screw.

11

Page 13: Influence ofHeat Treatment on Photodesorption of Copper Plated …lss.fnal.gov/archive/other/ssc/ssc-n-849.pdf · 2006. 8. 23. · 4.1% in the annealed sample. The average grain size

tube#024100

II

o-H2io 0 x-CH4

0 +-co- 0

.-C02+ Oct0102. -t +

++-tt 00

t+i2-3 x -4t-’i-010 x .-i-fl 0-c

I.

0 eXxx° ++E

t-4-.

C -

xx

1 o6 -

1Oi18 .1019 io2O i021 .1022 1o23

photons/rn

Figure5. Photondesorptionmeasurementresultsof tube #024 1988-90SilvexCu platedSSuntreated.

12

Page 14: Influence ofHeat Treatment on Photodesorption of Copper Plated …lss.fnal.gov/archive/other/ssc/ssc-n-849.pdf · 2006. 8. 23. · 4.1% in the annealed sample. The average grain size

tube#034100

1 * ‘I

o-H2101. x-CH4

+-co2 0 .-C02

10* 0+ 0

c -* 0%

0 +3a x

Xx

10

1o6

- ....*..

io2° io2’ io23 ia24photons/rn

Figure6. Photondesorptionmeasurementresultsof tube #034 1993 Silvex CuplatedSSuntreated.

13

Page 15: Influence ofHeat Treatment on Photodesorption of Copper Plated …lss.fnal.gov/archive/other/ssc/ssc-n-849.pdf · 2006. 8. 23. · 4.1% in the annealed sample. The average grain size

tube#008v100

*I ‘I ‘I

o-H210’ x-CH4

- 0 +-co- .-C02

0++.. 0

C -* 0

1:::xxx

:: :

1

10

1019 iozO o22 io24photons/rn

Figure7. Photondesorptionmeasurementresultsoftube#008v1988-90SilvexCu plated SS, Annealedat 700°C for 2 hours with a moving stagefUrnace. -

14

Page 16: Influence ofHeat Treatment on Photodesorption of Copper Plated …lss.fnal.gov/archive/other/ssc/ssc-n-849.pdf · 2006. 8. 23. · 4.1% in the annealed sample. The average grain size

tube#007v100 J,..II.PI ul1uu1 1 *1

o-H210_i x-CH4

- +-co0 .-C02162* 0

0+ - 0C

0+++*-a ++ - 00x

--E -4 x x ++10xC, x

5 X10 xx

1 o6

o19 o23 1024photons/rn

Figure8. Photondesorptionmeasurementresultsoftube#007v 1988-90SilvexCu plated55, Annealedat 700°Cfor 5 hoursin alargefurnace.