info_tech_uk 09_08

52
General catalogue TECHNICAL INFORMATION Info Tech September 2008

Upload: georossi46

Post on 26-Dec-2014

299 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: INFO_TECH_UK 09_08

General catalogueTECHNICAL INFORMATION

Info TechSeptember 2008

Page 2: INFO_TECH_UK 09_08

Baxi

2

BAXI ITALY, a Baxi Group company and one

of the leaders of the heating sector

in Europe, has a proud tradition of developing

and producing boilers and heating systems to

the highest technological standards.

For over 30 years BAXI ITALY has provided a

wide range of cutting-edge solutions,

anticipating market evolutions with particular

attention to customer needs.

Page 3: INFO_TECH_UK 09_08

Info Tech

3

Baxi has been very successful thanks to the attention

to its products quality.

Back in 1993 Baxi was awarded the ISO 9001

Certifi cation and in 2002 the ISO 9001:2000

Certifi cation in order to reach constantly the highest

levels of quality.

As Baxi recognizes environment, health and safety

protection as strategic aims, other prestigious

acknowledgements came in 2001 (ISO 14001)

and in 2004 (OHSAS 18001).

Baxi success is based on perfect agreement of all its

components, people, products and technology.

And its high quality standards

Training is a crucial issue for high effi ciency appliances

and Baxi invests consistently in providing detailed

technical data and hands-on educational courses.

The newly developed “Baxi Training Centre” welcomes

several thousand people every year.

Page 4: INFO_TECH_UK 09_08

4

GuidelinesIn order to complete all the product commercial details, Info Tech goes

deep into technical aspects of the wide range of Baxi boilers and high

technology heating systems.

In this catalogue the specifi c technical sections have been divided into

product categories. For each section technical drawings and

accessories are divided by product range.

In the commercial catalogue (INFO COMM)

Technical

drawings

Graphs

Flue systems

Flue tube

accessories

Hydraulic

accessories

Thermo-

regulation

accessories

Other

accessories

In the commercial catalogue we show the complete range of BAXI

products. On each page in addition to the product benefi ts,

there are a detailed list of the appliance characteristics,

a technical chart, and coloured icons, referring to the specifi c

pages of this technical manual.

General catalogueCOMMERCIAL INFORMATION

Info CommSeptember 2008

Page 5: INFO_TECH_UK 09_08

Info Tech

5

Index

Technical drawings

Graphs

Flue systems

Condensing gas boilers pag. 6

Gas boilers pag. 9

High effi ciency condensing systems pag. 15

Flue systems pag. 20

Solar collectors pag. 30

Indirect cylinders pag. 31

Electric water heaters pag. 32

Gas water heaters pag. 33

Flue tube accessories pag. 34

Hydraulic accessories pag. 40

Thermoregulation accessories pag. 43

Other accessories pag. 45

Products technical data pag. 48

Page 6: INFO_TECH_UK 09_08

6

Luna3 Comfort HT240, 280, 330,1.120, 1.240, 1.280

MR Heating system fl ow G 3/4”US DHW outlet G 1/2” (for heating only models storage tank fl ow G 3/4”)GAS Gas inlet G 3/4”ES Mains water G 1/2”RR Heating system return G 3/4”SC Condensing trap possible to connect on a pipe Ø 21A Boiler hanging points. Distance between hanging points: 425 mmB Distance between hanging points and hydraulic connection

Condensing gas boilers

1 DHW outlet G 1/2”2 Mains water G 1/2”3 Heating system return G 3/4” 4 Heating system fl ow G 3/4”5 Gas inlet G 3/4”SC Condensing trap

Nuvola3 Comfort HT240, 330

177 Luna3 Comfort HT 1.120

I speedII speed

III speed

HE

AD

mH

2O

FLOW RATE (l/h)

Luna3 Comfort HT 240 - 1.240 - 280

I speed.II speed.

III speed.

HE

AD

mH

2O

FLOW RATE (l/h)

Luna3 Comfort HT 1.280 - 330

I speed.II speed.

III speed.HE

AD

mH

2O

FLOW RATE (l/h)

Nuvola3 Comfort HT 240

I speed. II speed.III speed.

HE

AD

mH

2O

FLOW RATE (l/h)

Nuvola3 Comfort HT 330

I speed.II speed.

III speed.HE

AD

mH

2O

FLOW RATE (l/h)

SC

bottom view

Page 7: INFO_TECH_UK 09_08

7

Technical drawings - graphs - fl ue systems

A Heating system fl ow G 3/4” MB Heating system return G 3/4” MC Gas supply pipe G 3/4” ME Mains water G 1/2” MF DHW outlet G 1/2” MG DHW recirculation G 1/2” MH Flue condensation runoffI Relief valve outlet

Luna3 Comfort HT + Combi120, 240, 330

Luna3 Comfort HT+Combi 120

I speed.

II speed. III speed.

HE

AD

mH

2O

FLOW RATE (l/h)

Luna3 Comfort HT+Combi 240

I speed.II speed.

III speed.

HE

AD

mH

2O

FLOW RATE (l/h)

Luna3 Comfort HT+Combi 330

I speed.II speed.

IIIspeed.H

EA

D m

H2O

FLOW RATE (l/h)

side view back view view from abovefrontal view

Luna3 Comfort HT 240 SolarLuna3 Comfort HT Solar - heating system circuit

I speed.II speed.

III speed.HE

AD

mH

2O

FLOW RATE (l/h)

Luna3 Comfort HT Solar

I speed. II speed.III speed.

HE

AD

mH

2O

FLOW RATE - Solar circuit

frontal view side view back view

A DHW relief valve outlet G 1/2”B Mains water G 1/2”C DHW recirculation G 1/2” D DHW outlet G 1/2”E Heating system fl ow G 3/4”F Gas supply pipe G 3/4”G Heating system return G 3/4”H Solar relief valve outlet G 1/2”I Collector inlet G 3/4”L Collector outlet G 3/4”

2056

600 640

273 433,5

89

103

95

600273

95 130 130

9085 95 90

190 65105

832

760

415

E F G

A B C D

H I L

Page 8: INFO_TECH_UK 09_08

8

Condensing gas boilersPrime HT1.120, 1.240, 240, 280, 330

MR Heating system fl ow G 3/4”US DHW outlet G 1/2” (for heating only models storage tank fl ow G 3/4”)GAS Gas inlet G 3/4” ES Mains water G 1/2” RR Heating system return G 3/4”SC Condensing trap possible to connect on a pipe Ø 21A Boiler hanging points. Distance between hanging points: 425 mmB Distance between hanging points and hydraulic connection

Prime Storage HT 240

Prime HT + Combi240

side viewfrontal view back view view from above

Prime Storage HT 240

HE

AD

mH

2O

FLOW RATE (l/h)

Prime HT + Combi 240

HE

AD

mH

2O

FLOW RATE (l/h)

bottom viewSC

A Heating system fl ow G 3/4” MB Heating system return G 3/4” MC Gas supply pipe G 3/4” ME Mains water G 1/2” M

F DHW outlet G 1/2” MG DHW recirculation G 1/2” MH Flue condensation runoffI Relief valve outlet

1 DHW outlet G 1/2”2 Mains water G 1/2”3 Heating system return G 3/4”4 Heating system fl ow G 3/4”5 Gas inlet G 3/4”SC Condensing trap

Prime HT 1.240 - 240 - 280

HE

AD

mH

2O

FLOW RATE (l/h)

Prime HT 1.120 - HT 330

HE

AD

mH

2O

FLOW RATE (l/h)

Page 9: INFO_TECH_UK 09_08

9

Technical drawings - graphs - fl ue systems

Luna3 Comfort240 Fi, 310 Fi, 1.240 Fi, 1.310 Fi

Luna3 Comfort240 i, 1.240 i

MR Heating system fl ow G 3/4”US DHW outlet G 1/2” (for heating only models storage tank fl ow G 3/4”)GAS Gas inlet G 3/4”ES Mains water G 1/2”RR Heating system return G 3/4”A Boiler hanging points. Distance between hanging points: 425 mmB Distance between hanging points and hydraulic connection

Gas boilersLuna3 Comfort 310 Fi - 1.310 Fi

HE

AD

mH

2O

FLOW RATE (l/h)

Luna3 Comfort 240 i - 1.240 i - 1.240 Fi - 240 Fi

HE

AD

mH

2O

FLOW RATE (l/h)

Luna3 Comfort Air250 Fi, 310 Fi

MR Heating system fl ow G 3/4”US DHW outlet G 1/2”GAS Gas inlet G 3/4”ES Mains water G 1/2”RR Heating system return G 3/4”A Boiler hanging points. Distance between hanging points: 425 mmB Distance between hanging points and hydraulic connection

Luna3 Comfort Air 250 Fi - 310 Fi

HE

AD

mH

2O

FLOW RATE (l/h)

Page 10: INFO_TECH_UK 09_08

10

Luna3 Blue 240 Fi - 1.240 Fi

II speed.III speed.

Luna3 Blue 280 Fi

I speed.II speed.

IIIspeed.

Luna3 Blue240 Fi, 280 Fi, 1.240 Fi

Luna3 Blue180 i, 240 i, 1.180 i

188100 C

Gas boilers

Luna3 Blue 180 i - 1.180 i - 240 i

II speed.III speed.

HE

AD

mH

2O

FLOW RATE (l/h)

HE

AD

mH

2O

FLOW RATE (l/h)

HE

AD

mH

2O

FLOW RATE (l/h)

MR Heating system fl ow G 3/4”US DHW outlet G 1/2” (for heating only models storage tank fl ow G 3/4”)GAS Gas inlet G 3/4”ES Mains water G 1/2”RR Heating system return G 3/4”

A Boiler hanging points. Distance between hanging points: 425 mmB Distance between hanging points and hydraulic connectionC Ø 110 180 i – 1.180 i Ø 130 240 i

Luna3 Comfort + Combi240 Fi, 310 Fi

A Heating system fl ow G 3/4” MB Heating system return G 3/4” MC Gas supply pipe G 3/4” ME Mains water G 1/2” MF DHW outlet G 1/2” MG DHW recirculation G 1/2” MH Flue condensation runoffI Relief valve outlet

Luna3 Comfort + Combi 310 Fi - 240 Fi

HE

AD

mH

2O

FLOW RATE (l/h)

view from aboveside viewfrontal view back view

Page 11: INFO_TECH_UK 09_08

11

Technical drawings - graphs - fl ue systems

Luna3 Comfort Max 250 Fi, 310 Fi

Luna3 Comfort Max 240 i

Nuvola3 Comfort140 Fi, 240 Fi, 280 Fi, 320 Fi

Nuvola3 Comfort240 i, 280 i

1 DHW outlet G 1/2”2 Mains water G 1/2”3 Heating system return G 3/4”4 Heating system fl ow G 3/4”5 Gas inlet G 3/4”

Luna3 Comfort Max 310 Fi

I speed.II speed.

III speed.HE

AD

mH

2O

FLOW RATE (l/h)

Luna3 Comfort Max 240 i - 250 Fi

II speed.III speed.

HE

AD

mH

2O

FLOW RATE (l/h)

Nuvola3 Comfort 140 Fi - 240 Fi/i

HE

AD

mH

2O

FLOW RATE (l/h)

Nuvola3 Comfort 280 Fi/i - 320 Fi

HE

AD

mH

2O

FLOW RATE (l/h)

MR Heating system fl ow G 3/4”US DHW outlet G 1/2”GAS Gas inlet G 3/4”ES Mains water G 1/2”RR Heating system return G 3/4”

A Boiler hanging points. Distance between hanging points: 425 mmB Distance between hanging points and hydraulic connection

bottom view

Ø100

Page 12: INFO_TECH_UK 09_08

12

Gas boilersNuvola3140 B40 Fi, 240 B40 Fi, 280 B40 Fi

Nuvola3240 B40 i, 280 B40 i

1 DHW outlet G 1/2”2 Mains water G 1/2”3 Heating system return G 3/4” 4 Heating system fl ow G 3/4”5 Gas inlet G 3/4”

Nuvola3 140 B40 Fi - 240 B40 Fi-i

Nuvola3 280 B40 Fi-i

Luna3 Silver Space250 Fi, 310 Fi

Luna3 Silver Space 250 Fi - 310 Fi

MR Heating system fl ow G 3/4”US DHW outlet G 1/2”GAS Gas inlet G 3/4”ES Mains water G 1/2”RR Heating system return G 3/4”A Boiler hanging points. Distance between hanging points: 524 mmB Distance between hanging points and hydraulic connection

HE

AD

mH

2O

FLOW RATE (l/h)

HE

AD

mH

2O

FLOW RATE (l/h)

HE

AD

mH

2O

FLOW RATE (l/h)

bottom view

Ø100

Page 13: INFO_TECH_UK 09_08

13

Technical drawings - graphs - fl ue systems

Eco3240 Fi,280 Fi,1.240 Fi

Eco3240 i1.240 i

100 120

Eco3 Compact240 Fi, 1.140 Fi, 1.240 Fi

Main Digit240 Fi

Eco3 Compact 240 Fi - 1.140 Fi - 1.240 Fi - 240 i - 1.140 i - 1.240 i

HE

AD

mH

2O

FLOW RATE (l/h)

Main Digit 240 Fi - 240i

HE

AD

mH

2O

FLOW RATE (l/h)

MR Heating system fl ow G 3/4”US DHW outlet G 1/2” (for heating only models storage tank fl ow G 3/4”)GAS Gas inlet G 3/4”

ES Mains water G 1/2”RR Heating system return G 3/4”A Boiler hanging points. Distance between hanging points: 425 mmB Distance between hanging points and hydraulic connections

Eco3 Compact240 i, 1.140 i, 1.240 i

Main Digit240 i

MR Heating system fl ow G 3/4”US DHW outlet G 1/2”GAS Gas inlet G 3/4”

ES Mains water G 1/2”RR Heating system return G 3/4”

MR Heating system fl ow G 3/4”US DHW outlet G 1/2” (for heating only models storage tank fl ow G 3/4”)

GAS Gas inlet G 3/4”ES Mains water G 1/2”RR Heating system return G 3/4”

frontal view frontal viewside view side view bottom view

MR US GAS ES RR

Eco3 280 Fi

HE

AD

mH

2O

FLOW RATE (l/h)

Eco3 240 Fi - 1.240 Fi - 240 i - 1.240 i

HE

AD

mH

2O

FLOW RATE (l/h)

bottom view

MR US GAS ES RR

70 65 65 65 65 70

12

0,5

400

frontal view side view

400

73

3

22

317

47

frontal view side view

Ø 122186,6

400 317

78

2

62

81

02

52

400

317

47

22

73

3

400 317

Ø 122186,6

78

2

62

81

02

52

70 65 65 65 65 70

400

14

1,2

Page 14: INFO_TECH_UK 09_08

14

Gas boilersSlim1.230 Fi, 1.300 Fi

Slim1.230 FiN, 1.300 FiN

Slim 2.300 Fi - 2.230 i - 2.300 i - 1.150 i

1.230 i - 1.300 i - 1.230 Fi - 1.300 Fi

0 0,2 0,4 0,6 0,8 1,0 1,2 1,4 1,6 1,8 2,0 2,2 2,4

I speed. II speed. III speed.

Slim1.150 i, 1.230 i,1.300 i

Slim1.230 iN,1.300 iN

Slim1.400 iN, 1.490 iN, 1.620 iN

frontal view side view frontal view side view back view

Slim2.300 Fi

Slim2.230 i, 2.300 i

back view back view side view frontal view

A Heating system fl ow G 3/4” MB Heating system return G 3/4” MC Gas supply pipe G 1/2” MD Mains water G 1/2” ME DHW outlet G 1/2” MF Recirculation G 1/2” M (Slim 2.260 Fi) Recirculation G 1/2” F (Slim 2.230 i, 2.300 Fi)

HE

AD

mH

2O

FLOW RATE (l/h)

frontal view side view back view back viewside view

AA

B

B

C C

520 - 600

481 - 564596 - 676

350

85

0

116 119 115542 - 622

520 - 600

481 - 561

507 - 587

A Heating system fl ow G 3/4” MB Heating system return G 3/4” MC Gas supply pipe G 1/2” M

L1

L2

L1

Slim 1.150i 520

Slim 1.230i 600

Slim 1.300i 680

dimensions (mm)

H L2

Slim 1.230iN 600 600

Slim 1.300iN 680 680

Slim 1.400iN 1490 635

Slim 1.490iN 1490 715

Slim1.620iN 1650 875

dimensions (mm)

Page 15: INFO_TECH_UK 09_08

sug

ge

ste

d 1

40

0

horizontal

GAS connection

15

Technical drawings - graphs - fl ue systems

MR Heating system fl ow G 3/4”MB Storage tank fl ow G 3/4”GAS Gas inlet G 3/4”ES Mains water G 1/2”RR Heating system return G 3/4”SC Condensing trap possible to connect on a pipe Ø 21A Boiler hanging points. Distance between hanging points: 425 mmB Distance between hanging points and hydraulic connection

Luna3 System HT1.180 MP, 1.240 MP, 1.330 MP*

Luna3 System HT 1.240 MP

maxspeedmin

speed

Luna3 System HT 1.180 MP

max speed

minspeed

Luna3 System HT 1.330 MP

maxspeed

minspeed

Luna HT (commercial applications)1.350, 1.450, 1.450P,1.550, 1.650

High effi ciency condensing systems

MB

HE

AD

mH

2O

FLOW RATE (l/h)

HE

AD

mH

2O

FLOW RATE (l/h)

HE

AD

mH

2O

FLOW RATE (l/h)

Luna HT 1.350-1.450-1.450P-1.550-1.6507000

6000

5000

4000

3000

2000

1200

0 1000 2000 3000 4000 5000

HE

AD

mH

2O

FLOW RATE (l/h)

Luna HT 1.350-1.450-1.450P-1.550-1.650

1000 2000 3000 4000 5000 6000

Exc

ha

ng

er

pre

ssu

re d

rop

mH

2O

FLOW RATE (l/h)

I speedII speed III speed

sug

ge

ste

d 1

40

09

50

GAS Gas inlet G 3/4”MR Heating system fl ow G 1”RR Heating system return G 1”SC Condensing trap possible to connect on a pipe Ø 21

*Luna3 System HT boilers are connectable to Combi 80 lt

Page 16: INFO_TECH_UK 09_08

16

High effi ciency condensing systems

GAS Gas inlet G 3/4”MR Heating system fl ow G 1-1/2”RR Heating system return G 1-1/2”SC Condensing trap possible to connect on a pipe Ø 21

horizontal

GAS connection

Luna HT 1.850-1.10009

8

7

6

5

4

3

2

1

0 1000 2000 3000 4000 5000 6000 7000 8000 9000

HE

AD

mH

2O

FLOW RATE (l/h)

Luna HT 1.850-1.1000

1000 2000 3000 4000 5000 6000

FLOW RATE (l/h)

Exc

ha

ng

er

pre

ssu

re d

rop

mH

2O

Luna HT (commercial applications)1.850-1.1000

Page 17: INFO_TECH_UK 09_08

17

Technical drawings - graphs - fl ue systems

Cabinets with 2condensing higheffi ciency boilers

Luna HT45-55-65 kW

Luna HT85-100 kW

Luna HT45-55-65 kW

Luna HT85-100 kW

Ø149

19

00

19

0

1600

800

309 160 33177

22

8

417

124

29

01

94

445 800 355

27

7,5

454,5 800 345,5

18

2,5

Ø149

19

00

19

0

2400800

309 160 33177

22

8

417

124

29

01

94

445 800 800 355

27

7,5

454,5 800 800 345,5

18

2,5

Cabinets with 3condensing higheffi ciency boilers

Dimensions (mm)

W H D

2 doors 1600 1900 800

Dimensions (mm)

W H D

3 doors 2400 1900 800

Page 18: INFO_TECH_UK 09_08

18

High effi ciency condensing systemsPower HT1.450-1.6501.850-1.10001.1200-1.1500

(*) 450 mm or 20 mm between boilers in cascade depending on manifold accessory used

Power HT 1.450-1.650

1000 1500 2000 2500 3000 3500 4000

Exc

ha

ng

er

pre

ssu

re d

rop

mH

2O

Power HT 1.850 - 1.1000

2000 3000 4000 5000 6000

Exc

ha

ng

er

pre

ssu

re d

rop

mH

2O

Power HT 1.1200-1.1500

3000 4000 5000 6000 7000 8000 9000

Exc

ha

ng

er

pre

ssu

re d

rop

mH

2O

45 cm

45 cm/2 cm

45 cm/2 cm

Power HT 1.450-1.650-1.850-1.1000-1.1200-1.15009

8

7

6

5

4

3

2

1

0 1000 2000 3000 4000 5000 6000 7000 8000 9000

HE

AD

mH

2O

Power HT 1.1500 1.1200 1.1150 1.1000 1.850 1.650 1.450

Depth (A) mm 1132 1024 1024 871 801 693 621

RVA positioning

FLOW RATE (l/h)

FLOW RATE (l/h)

FLOW RATE (l/h)

FLOW RATE (l/h)

GAS Gas inlet G 3/4”

MR Heating system fl ow G 1-1/2”

RR Heating system return G 1-1/2”

Page 19: INFO_TECH_UK 09_08

19

Disegni tecnici dimensionali - grafi ci portata prevalenza Technical drawings - graphs - fl ue systems

Models: Luna Sat R/1 - RP/1 - RS - RSP - RA

Models: Luna Sat R2Z - RS2Z - RA2Z

above view

case width 800

above view

case width 600

LegendaCentralized system connectionsIP: primary inlet from centralized system G 3/4’’ MUP: primary outlet to centralized system G 3/4’’ M

Heating system connections – single zone modelsMR: heating G 3/4” M system fl owRR: heating G 3/4” M system return

Heating system connections – double zone modelsMRAT: high temperature G 3/4’ M system fl ow(R2Z and RS2Z models)MRBT: low high temperature G 3/4” M system fl ow(R2Z and RS2Z models)RRAT: high temperature G 3/4” M system return(R2Z and RS2Z models)RRBT: low temperature G 3/4” M system return(R2Z and RS2Z models)

DHW system connectionsES (*): Mains water G 1/2” M (RS, RSP, RS2Z models)US: DHW outlet G 1/2” M (RS, RSP, RS2Z models)

DHW consumption meter connectionsESC1 (*): Mains water to heat meter G 3/4” MES (*): DHW outlet fi rst volumetric meterESC2 (*): Mains water to the second heat meter G 3/4” M(R, RP, R2Z models)US(*):DHW outlet second volumetric meterUSC: volumetric meter outlet (RH model)

(*) in case of installation of the volumetric meter (available as optional) the Mains water has to be transferred in the hydraulic connection ESC1 (o ESC2)

Models: Luna Sat RH

above view

case width 650

USC USC

Models: Luna Sat R/1 - RP/1

screw seatsconnection tongues

frontal view

L 600

con

ne

ctio

n k

it 3

0

case width 150

left side view

H c

ase

65

0

38

,5 50

50

64

Models: Luna Sat R2Z - RS2Z - RA2Z

screw seatsconnection tongues

frontal view

L 800

con

ne

ctio

n k

it 3

0

case width 150

left side view

H c

ase

75

0

38

,5 50

50

64

Models: Luna Sat RS - RSP - RA

case width 150

left side view

H c

ase

65

0

38

,5 50

50

64

screw seatsconnection tongues

frontal view

L 600

con

ne

ctio

n k

it 3

0

Models: Luna Sat RH

con

ne

ctio

n k

it 3

0

frontal view

P case 150

H c

ase

65

0

left side view On all the case sides there are holes dedicated to the hydraulic connections.

Page 20: INFO_TECH_UK 09_08

20

Coaxial fl ue systemLuna3 Comfort HT - Nuvola3 Comfort HT - Luna3 Comfort HT + CombiLuna3 Comfort HT Solar - Prime HT - Prime Storage HT - Prime HT + Combi

■ Ø 60/100 mm ■ Ø 80/125 mm

Prime HT + Combi

Luna3 Comfort HT Nuvola3 Comfort HT

frontal view side view

220

11

7 m

in

600

239

466

Prime Storage HTPrime HT

frontal view side view

177 140,5

450 345

12

7 m

in

frontal view side view

220 239

600 466

L max= 9 mL max= 9 m

L max= 10 m L max= 10 m

24 m24 m

25 m 25 m

L max= 10 m

99

8

34

5

99

8

40

5

L max= 10 m L max= 9 m

99

8

34

5

L max= 8 m

99

8

34

5

LAS chimney

L max= 10 m L max= 10 m25 m25 m

23 m24 m25 m25 m

LUNA3 COMFORT HT

NUVOLA3 COMFORT HT

LUNA3 COMFORT HT SOLAR 10 25 1 0,5

LUNA3 COMFORT HT + COMBI

PRIME HT

PRIME STORAGE HT

PRIME HT + COMBI

Tubes maximum length (m)

Ø 60/100 Ø 80/125

Length reductionfor a 90°

bend insertion (m)

Length reductionfor a 45°

bend insertion (m)

frontal view side view

177 140,5

450 345

12

7 m

in

Luna3 Comfort HT + Combi

frontal view

450

side view

550

346177

12

7 m

in

frontal view

450

side view

550

346177

12

7 m

in

Luna3 Comfort HT Solar

frontal view

600

273

side view

640

433,5

11

2 m

in

11

7 m

in

Page 21: INFO_TECH_UK 09_08

21

Luna3 Comfort - Luna3 Comfort + Combi - Luna3 Comfort Air - Luna3 BlueLuna3 Comfort Max - Luna3 Silver Space - Eco3 - Eco3 Compact - Main Digit

Eco3 Compact - Main Digit

view from above side view frontal view side view side view

132400

317

4786

24

85

73

3

22

63

view from above

L maxL max

L maxL max

L max L max

LAS chimney

34

5

99

8

L max

99

8

34

5

L max

99

8

34

5

L max

99

8

40

5

L max

Luna3 Comfort - Luna3 Comfort AirLuna3 Blue - Luna3 Comfort Max - Eco3

side view

345

frontal view

14

3 m

in

450

188100

Luna3 Silver Space

100 76

226 324 250

14

3 m

in

side viewfrontal view

Luna3 Comfort + Combi

frontal view

450

100

14

3 m

in

side view

550

398

Technical drawings - graphs - fl ue systems

Horizontal Luna3 - Eco3 24/25 kW 5 9

fl ue Luna3 - Eco3 28/31 kW 4 8

Luna3 Blue 4 -

Eco3 Compact/Main Digit 5 - 1 0,5

Vertical Luna3 - Eco3 4 10

chimney Luna3 Blue 4 -

Eco3 Compact/Main Digit 4 -

Tubes maximum length (m)

Ø 60/100 Ø 80/125

Length reductionfor a 90°

bend insertion (m)

Length reductionfor a 45°

bend insertion (m)

Lmax can change according to the fl ue type. See the instruction manual.

Page 22: INFO_TECH_UK 09_08

22

Coaxial fl ue systemNuvola3 Comfort - Nuvola3

frontal view

100

side view

150

424 176 466

12

0 m

in.

L max

99

8

34

5

L max

99

8

40

5

L max

99

8

34

5

L max

34

5

99

8

L max

L max

L max L max

L max L max

LAS chimney

Slim

L max= 5 m

L max= 3 m

L max= 3 m

L max= 4 mL max= 4 m

Flue lass

L max= 3 mL max= 3 m

L max= 4 m

99

8

34

5

L max= 4 m

99

8

40

5

L max= 3 m

99

8

34

5

L max= 3,5 m

99

8

34

5

Horizontal 24/28 kW 4 8

fl ue 14 kW 5 8

32 kW 3 8 1 0,5

Vertical 4 -

chimney

Tubes maximum length (m)

Ø 60/100 Ø 80/125

Length reductionfor a 90°

bend insertion (m)

Length reductionfor a 45°

bend insertion (m)

Slim 2.300 Fi

above view

100

10

2 m

in.

416234

side view

102 min.

10

0

Slim 1.230 Fi/FiN, 1.300 Fi/FiN

10

2 m

in.

above view

100

116234

side view

102 min.

10

0

5 1 0,5 60 - 100

Tubesmaximum

length(m)

Length reduc-tion for a 90°

bend insertion (m)

Length reduc-tion for a 45°

bend insertion (m)

Ø fl uemm

Page 23: INFO_TECH_UK 09_08

23

Luna3 System HT - Luna HT (from 35 kW to 100 kW) single installation

L max L max

L max L max

L max L max

LAS chimney

L max

34

5

99

8

L max

99

8

34

5

L max

99

8

40

5

L max

34

5

99

8

Luna3 System HT 10 25 -

Luna HT 35/45/55/65 kW - 10 - 1 0,5

Luna HT 85/100 kW - - 10

Tubes maximum length (m)

Ø 60/100 Ø 80/125

Length reductionfor a 90°

bend insertion (m)

Length reductionfor a 45°

bend insertion (m)Ø 110/160

Luna3 System HT

12

7 m

in.

frontal view side view

450

= =

345

186

frontal view side view

600 650

131245,5

27

0 m

in.

Luna HT 1.850 - 1.1000

frontal view side view

600 466

255

11

9 m

in.

226

Luna HT 1.350 - 1.450 - 1.450P1.550 - 1.650

Technical drawings - graphs - fl ue systems

Page 24: INFO_TECH_UK 09_08

24

Dual fl ue systemLuna3 Comfort HT - Nuvola3 Comfort HT - Luna3 Comfort HT + Combi Luna3 Comfort HT Solar - Prime HT - Prime Storage HT - Prime HT + Combi

Installation with Terminal Ø 60

30 3 1,25

Installation with Terminal Ø 80 80 0,5 0,25

Installation with Chimney Terminal 15 0,5 0,25

Tubes maximumlength (m)

Length reduction for a 90°bend insertion (m)

Length reduction for a 45°bend insertion (m)

L1 = FLUE PIPE / L2 = INTAKE PIPE

L1 L2 L2 L1 L max 960

300

15

11

50

50

0

14

50

0 11

50

Luna3 Comfort HT

110

frontal view side view

120 110

177

15

9 m

in.

140,5

345

Nuvola3 Comfort HT

frontal view side view

600 466

11041

110

14

9 m

in.

239

126

frontal view side view

600 466

11041

110

14

9 m

in.

239

126

Prime Storage HT

Luna3 Comfort HT Solar Prime HT

110

frontal view side view

120 110

177

15

9 m

in.

140,5

345

Prime HT + Combi

Luna3 Comfort HT + Combi

110

frontal view side view

120 110

177

15

9 m

in.

346

550

110

frontal view side view

120 110

177

15

9 m

in.

346

550

frontal view side view

110 120 110

15

9 m

in.

433,5

327

450 450

450600 640

450

Page 25: INFO_TECH_UK 09_08

25

Technical drawings - graphs - fl ue systems

Flexible ducting systems gas condensing boilers

Page 26: INFO_TECH_UK 09_08

26

Dual fl ue systemLuna3 Comfort - Luna3 Comfort Air - Luna3 Comfort + Combi - Luna3 Blue - Luna3 Comfort MaxLuna3 Silver Space - Eco3 - Eco3 Compact - Main Digit

L

50

0 11

50

11

50

50

0

L

L1 L2 L2 L1

side view

188

345

frontal view

94

frontal view

94 94 94

120 120

450 45014

3 m

in

14

3 m

in

frontal view side viewfrontal view

14

3 m

in

94 94 94 94

120226 324

120226 324 250

14

3 m

in

Luna3 Comfort - Luna3 Comfort Air - Luna3 Blue Luna3 Comfort Max - Eco3

Luna3 Silver Space

Eco3 Compact - Main Digit

960

300

L

2734

149

68

92

53

149

68

53 92

3427

above view frontal view side view side view frontal view above view

If the pipe length is longer than 6 meters you have to install the condensation storage kit.

(L1+L2) MAX m 40 25 20 40 25 30 30 (G20) - 25 (G31) 25

L2 MAX m 10 10 10 10 10 10 10 10

*B22 - - - - - - 25 22

Luna3 Comfort

25 kW 31 kW

Luna3Blue

Eco3

24 kW 28 kW

Eco3Compact

Main Digit

Luna3 Silver Space*

25 kW 31 kW

Luna3 Comfort Eco3

L MAX m 10 8 10 10 8 10

25 kW 31 kW

Luna3Blue

Eco3Compact

Main Digit24 kW 28 kW

L MAX m 15 12 10 15 12 12

Luna3 Comfort

25 kW 31 kW

Luna3Blue

Eco3 Eco3Compact

Main Digit24 kW 28 kW

L MAX m 14 10 9 14 10 10

Luna3 Comfort

25 kW 31 kW

Luna3Blue

Eco3 Eco3Compact

Main Digit24 kW 28 kW

INSTALLATION WITH TERMINAL Ø 60 30 3 1,25

INSTALLATION WITH TERMINAL Ø 80 80 0,5 0,25

INSTALLATION WITH CHIMNEY TERMINAL 15 0,5 0,25

TUBES MAXIMUMLENGTH (m)

LENGTH REDUCTION FOR A 90° BENDINSERTION (m)

LENGTH REDUCTION FOR A 45° BENDINSERTION (m)

side view

550

398

Luna3 Comfort + Combi

frontal view

94

frontal view

94 94 94

120 120

450 45014

3 m

in

14

3 m

in

Page 27: INFO_TECH_UK 09_08

27

Technical drawings - graphs - fl ue systems

Nuvola3 Comfort - Nuvola3

Slim

L1 L2 L2 L1 960

3005

00 1

15

0

L m

ax=

5,5

m

50

01

15

0

L max=4,5 m

FLUE PIPE (L1) MAXIMUM LENGTH WITH A 90° BEND: 10 m.

INTAKE PIPE (L2) MAXIMUM LENGTH WITH A 90° BEND: 10 m.

L2

L1960

300

L

65

01

15

0L L

11

50

65

0

Installation withproof terminal

20 0,5 0,25 80

Installation withchimney terminal

6 0,5 0,25 133

Tubes maximumlength (m)

Length reduction for a90° bend insertion (m)

Length reduction for a45° bend insertion (m)

Ø Flue (mm)

97 97

119

115 235

above view

10

1,5

min

above view

97 97

119

234 416

10

1,5

min

Slim 1.230 Fi/FiN, 1.300 Fi/FiN

Installation with 0,5 0,25 80proof terminal

Installation with 0,5 0,25 133chimney terminal

Length reduction for a 90° bend insertion (m)

Length reduction for a 45° bend insertion (m)

Ø Flue(mm)

153 120

side viewfrontal view

94 94

13

5 m

in.

Slim 2.300 Fi

Page 28: INFO_TECH_UK 09_08

28

Dual fl ue systemLuna3 System HT (single installation)

LENGTH REDUCTION FOR A 90° BEND

INSERTION (m)

LENGTH REDUCTION FOR A 45° BEND

INSERTION (m)

0,5 0,25

INTAKE PIPE MAXIMUM LENGTH: 15 m

Luna HTfrom 35 to 100 kW(single installation)

LENGTH REDUCTION FOR A 90° BEND

INSERTION (m)

LENGTH REDUCTION FOR A 45° BEND

INSERTION (m)

0,5 0,25

INTAKE PIPE MAXIMUM LENGTH: 15 m

110

frontal view side view

120 110 186

15

9 m

in.

450

345

144

frontal view side view

255 226

11

2 m

in.

11

2 m

in.

600 D

Luna HTfrom 85 to 100 kW(single installation)

INTAKE PIPE MAXIMUMLENGTH: 7 m

170

frontal view side view

245,5 131

21

4

23

0

600 650

L1

(L1+L2) max= 80 m L max= 15 m

L max= 15 m L max= 14 m

L2 L

L

L

L max= 15 m

L L1 L2

L

L

L1 L2

(L1+L2) max= 60 m (L1+L2) max= 27 mL max= 15 m L max= 14 m

Page 29: INFO_TECH_UK 09_08

29

Technical drawings - graphs - fl ue systems

Power HT

Cascade installationLuna3 System HT

Luna HT(commercial applications)

Page 30: INFO_TECH_UK 09_08

30

Collectors for forced draft installationSB 25 SB 25 IN

SB 13 IN

Collectors for natural draft installation

SB 20

Optimum volume percentage of non-toxic antifrost liquid

(SB 25, SB 25 IN, SB13 IN)

Non-toxic antifrost Freezing point

23 -10°C

32 -15°C

37 -20°C

Optimum volume percentage of non-toxic antifrost liquid

Non-toxic antifrost Freezing point

23 -10°C

32 -15°C

37 -20°C

SB 20 SR

SB 21

h x w x d (mm)

SB 20 1947 982 95

SB 21 1230 1170 95

h x w x d (mm)

SB 25 2150 1170 83

SB 25 IN 2058 1227 105

SB 13 IN 1015 1227 105

SB 20 SR 1947 982 95

Dimensions referred to a single collector

SB 20 effi ciency collector with G=800 W/m2

SB 21 effi ciency collector with G=800 W/m2

SB 25 E SB 25 IN Collectors effi ciency with G=800 W/m2

Absorber

Absorber

Absorber

Page 31: INFO_TECH_UK 09_08

200 LT 300 LT 400 LT 500 LT 800 LT 1000 LT 1500 LT 1000 LT

31

Indirect cylinder

Technical drawings - graphs - fl ue systems

LUNA UB INOXLUNA UB 80, 120

SLIM UB INOXSLIM UB 80, 120

45-120 45-120450 - 600

UB 200 SC/DC,UB 300 SC/DC,UB 400 SC/DC

UB 500 DC, UB 800 DC,UB 1000 SC/DC,UB 1500 DC,UB 2000 SC

UBTT 1000,UBPT 1000,UBPU 1500 SC

UB 200 SC/DC 1310x600

UB 300 SC/DC 1780x600

UB 400 SC/DC 1575x740

UB 500 DC 1805x760

UB 800 DC 1905x990

UB 1000 SC 2155x940

Dimensions (mm) H x Ø

UB 1000 DC 2155x990

UB 1500 DC 2285x1200

UB 2000 SC 2520x1300

UBTT 1000 2090x990

UBPT 1000 2110x1030

UBPU 1500 SC 2150x1200

Dimensions (mm) H x Ø

Luna 3 Comfort HT + Combi

1.120-1.240-1.280 models

+ =

Luna3 Comfort + Combi

1.240 Fi - 1.310 Fi - 1.240 i models

+ =

Prime HT + Combi

1.120 -1.240 models

+ =

Luna3 System HT + Combi

1.180 MP-1.240 MP-1.330 MP models

+ =

A Connection heating system fl ow/indirect cylinder 3/4”MB Connection indirect cylinder

return/heating system 3/4” M

C Mains water 1/2” M D Domestic hot water outlet 1/2” ME Relief valve 1/2” FF Recirculation 1/2” M

SOLUTIONS WITH COMBI 80 lt

Combi 879x450x550

Luna3 Comfort HT + Combi 1642x450x550

Luna3 System HT + Combi 1642x450x550

Prime HT + Combi 1642x450x550

Luna3 Comfort + Combi 1642x450x550

Dimensions (mm) h x w x d

Page 32: INFO_TECH_UK 09_08

32

Electric water heaters

upright 50/80/100 lt

horizontal 80/100 lt

H H1

50 lt upright 520 360

80 lt upright 760 565

100 lt upright 920 760

80 lt horizontal 760 395

100 lt horizontal 920 555

dimensions (mm)

10 lt 15 lt

A 267 350

B 250 310

C 70 100

D 128 168

dimensions (mm)

STORAGE

upright 30 lt

10-15 lt, ABOVE AND UNDER SINK

Page 33: INFO_TECH_UK 09_08

H H1 H

2

50 lt upright TD/TS 520 360 165

80 lt upright TD/TS 760 565 250

100 lt upright TD/TS 920 760 250

80 lt horizontal TD/TS 760 395 250

100 lt horizontal TD/TS 920 555 250

dimensions (mm)

33

Technical drawings - graphs - fl ue systems

Gas storage water heaters

33

WALL HUNGSAGN 50SAGN 80SAGN 100

A 306 591 676

B 490 775 860

C 613 898 983

D 265 550 635

FLOOR STANDING

SAG 115 TSAG 150 T

SAG 200 T

A 470 470 570

B 1215 1515 1414

C 1274 1574 1485

D 374 374 337

E 674 824 747

upright 50/80/100 lt

horizontal 80/100 lt

STORAGE THERMOELECTRIC

1 2

dimensions (mm)

dimensions (mm)

1

Page 34: INFO_TECH_UK 09_08

34

Coaxial fl ue systemGas condensing boilers Luna3 Comfort HT

Nuvola3 Comfort HTPrime HT

KHG714100211

KHG714093510

KHG714100112

KHG714059611

KHG714088910

KHG714059514

KHG714088511

KHG714088610

KHG714099810

KHG714099710

PP HORIZONTAL COAXIAL CHIMNEY 110/160

PP VERTICAL CHIMNEYTERMINAL 80/125

PP VERTICAL CHIMNEYTERMINAL 110/160

PP COAXIAL FLUE TUBES WITHTERMINAL 60/100 L=750 mmsupplied with windproof terminaland sealing collar

PP COAXIAL FLUE TUBES WITH TERMINAL 80/125 L=1000 mm supplied with wind proof terminal and sealing collar

PP COAXIAL FLUE TUBEEXTENSION 60/100L=1000 mm

PP COAXIAL FLUE TUBEEXTENSION 80/125L=1000 mm

PP COAXIAL FLUE TUBEEXTENSION 80/125L=500 mm

PP COAXIAL FLUE TUBEEXTENSION 110/160L=1000 mm

PP COAXIAL FLUE TUBEEXTENSION 110/160L=500 mm

KHG714059715

KHG714088711

KHG714100010

KHG714059815

KHG714088811

KHG714099910

KHG714093910

KHG714093610

KHG714104810

KHG714093710

KHG714104910

PP COAXIAL 87°BEND 60/100

PP COAXIAL 87°BEND 80/125

PP COAXIAL 87°BEND 110/160

PP COAXIAL 45°BEND 60/100

PP COAXIAL 45°BEND 80/125

PP COAXIAL 45°BEND 110/160

PP REDUCTION FROM80/125 TO 60/100

FLAT ROOF TILE TO BEUSED WITH A VERTICALCHIMNEY TERMINAL 80/125

FLAT ROOF TILE TO BEUSED WITH A VERTICALCHIMNEY TERMINAL 110/160

PITCHED ROOF TILE TO BE USED WITH A VERTICALCHIMNEY TERMINAL 110/160;it is adjustable from 15° to 45°

PITCHED ROOF TILE TO BE USED WITH A VERTICALCHIMNEY TERMINAL 80/125;it is adjustable from 15° to 45°

INTERNAL SEALINGCOLLAR Ø 100

KHG714017710

Luna3 System HTLuna HT

35/45/55/65 kWLuna HT

85/100 kW

+KHG 714093910+KHG 714093910

Kit available for every range model. Otherwise specifi ed.

Page 35: INFO_TECH_UK 09_08

35

Flue tube accessories

Fanned fl ue gas boilers

KHG714101810

KHG714036410

KHG714101710

KHG714103910

KHG714101410

KHG714101510

KHG714087710

KHG714101910

KHG714036710

KHG714036610

KHG714017710

COAXIAL FLUE TUBESWITH TERMINAL 60/100

VERTICAL CHIMNEY TERMINALFOR COAXIAL FLUE SYSTEM

COAXIAL FLUE TUBEEXTENSION 60/100L=1000 MM

COAXIAL FLUE TUBEEXTENSION 60/100L=500 MM

STARTING COAXIAL90° BEND

COAXIAL 90° BEND

COAXIAL CONDENSATECOLLECTOR KIT

ADAPTER FOR 45°BEND/VERTICAL CHIMNEY

FLAT ROOF TILE

PITCHED ROOF TILE

INTERNAL SEALINGCOLLAR Ø 100

Luna3models

Eco3 SlimNuvola3ComfortNuvola3

KHG714101610 COAXIAL 45° BEND

Coaxial fl ue system

KHG714059113

KHG714089010

KHG714105011

KHG714111010

KHG714075610

KHG714093510

KHG714093810

PP DUAL FLUE SYSTEM Ø 80it includes: fl ue reduction,intake connection

PP DUAL FLUE SYSTEM Ø 80it includes: fl ue reduction,intake connection

PP DUAL FLUE SYSTEM Ø 110it includes: fl ue reduction,intake connection

PP reduction fromØ 80 to Ø 60

COAXIAL VERTICALCHIMNEY TERMINAL80/125

DUAL FLUE TUBESADAPTER FORCOAXIAL CHIMNEY

Luna3 Comfort HTNuvola3 Comfort HT

Prime HTLuna3 System HT Luna HT

85/100 kW Power HTLuna HT

35/45/55/65 kW

+KHG 714093810 +KHG 714093810

Gas condensing boilers

Dual fl ue system

Eco3Compact

Main Digit

KHG714102310STARTING COAXIAL45° BEND

KHG714104110 COAXIAL 90° BEND WITH CHECKING PROFILE

KHG714089410COAXIAL FLUE TUBE FORCONNECTION TO LAS SYSTEM

KHG714104010COAXIAL FLUE TUBEEXTENSION 60/100 WITHCHECKING PROFILE

PP vertical fl ue system B23type installation

+KHG 714093810

Kit available for every range model. Otherwise specifi ed.

Page 36: INFO_TECH_UK 09_08

36

Dual fl ue systemGas condensing boilers

KHW714096910

KHG714059211

KHW714097310

KHG714059311

KHG714075510

KHW714097210

KHG714037411

KHG714106110

KHG714037310

KHG714018510

PP REDUCTION KITFROM Ø 110 TO Ø 100

PP 87° BEND Ø 80

KHG714018411

KHG714093610

KHG714104810

KHG714093710

KHG714010410

KHG714037210

KHG714075410

KHG714051510

KHG714104910

TUBE Ø 80 CENTRINGPack of 5

CLAMPCENTRING KIT

TUBE Ø 60 CENTRING KITPack of 5

TUBE Ø 80 SUPPORTINGBRACKETPack of 5

INTERNAL SEALINGCOLLAR Ø 80

EXTERNAL SEALINGCOLLAR Ø 80

FLAT ROOF TILE Ø 125 TOBE USED WITH A VERTICALCHIMNEY TERMINAL

FLAT ROOF TILE Ø 160 TOBE USED WITH A VERTICALCHIMNEY TERMINAL

PITCHED ROOF TILE Ø 125 to be used with a vertical chimney terminal; it is adjustable from 15° to 45°

PITCHED ROOF TILE Ø 160 to be used with a vertical chimneyterminal; it is adjustable from 15° to 45°

DUAL FLUE TERMINALØ 80

DUAL FLUE TERMINALØ 60

LSD790000450

85-150

45-65

85-150

45-65

85-150

45-65

45-65

45-65

45-65

45-65

45-65

45-65

Luna3 Comfort HTNuvola3 Comfort HT

Prime HTLuna3 System HT Luna HT

85/100 kW Power HTLuna HT

35/45/55/65 kW

KHG714059910

KHG714075310

KHG714075210

KHW714097110

PP TUBE EXTENSION Ø 80L=1000 mm

PP TUBE EXTENSION Ø 80L=500 mm

PP TUBE EXTENSION Ø 60L=1000 mm

PP TUBE EXTENSION Ø 110L=1000 mm

PP TUBE EXTENSION Ø 60L=500 mm

PP TUBE EXTENSION Ø 110L=500 mm

KHW714097010

KHG714059411 45-65

45-65

85-150

85-150

PP 90° BEND Ø 60

PP 87° BEND Ø 110

PP 45° BEND Ø 110

PP 45° BEND Ø 60

PP 45° BEND Ø 80

FLUE TERMINALØ 80

Kit available for every range model. Otherwise specifi ed.

Page 37: INFO_TECH_UK 09_08

KHG714105710

KHG714105810

KHG714106010

KHG714106210

PP FLEXIBLE TUBEØ 80 L= 1,5 m

PP 90° BEND Ø 80 WITHSUPPORTING BRACKET ANDCONDENSATE DRAININGs

FLEXIBLE CENTRING KITØ 80 (pack of 3)

PP 90° BEND Ø 80 WITHSUPPORTING BRACKET

KHG714111210

KHG714105910

PP FLEXIBLE TUBEØ 80 L= 20 m

Flue tube accessories

37

KHG714061511

KHG714017912

KHG714074810

KHG714111810

KHG714018310

KHG714018210

KHG714038710

DUAL FLUE AFRSYSTEM KIT

KHG714038610

KHG714038510

KHG714105410

KHG714105310

KHG714018010

PAINTED INSULATEDTUBE Ø 80L=500 mm

BEND 90°Ø 80

PAINTED INSULATEDTUBE Ø 80L=1000 mm

ALUMINIUM TUBE Ø 80L=1000 mm

ALUMINIUM TUBE Ø 80L=500 mm

ALUMINIUM TUBE Ø 80L=2000 mm

PAINTED TUBE Ø 80L=500

PAINTED TUBE Ø 80L=1000

DUAL FLUE KIT

Fanned fl ue gas boilers

Dual fl ue system

Luna3Blue

Luna3Silver Space

KHG714105110 INSULATED BEND 90°Ø 80

Luna3models Eco3 Slim

Nuvola3ComfortNuvola3

Eco3Compact

Main Digit

Luna3 Comfort HTNuvola3 Comfort HT

Prime HTLuna3 System HT Luna HT

85/100 kW Power HTLuna HT

35/45/55/65 kW

DUAL FLUE KIT

TRIPLE LIPS GASKETS KITØ 80 (pack of 5)

DUAL FLUE KIT FOR B22 INSTALLATION TYPE Ø 80

Kit available for every range model. Otherwise specifi ed.

Flexible ducting system

Page 38: INFO_TECH_UK 09_08

Fanned fl ue gas boilers

KHG714018110

KHG714105210

KHG714030510

KHG714054710

KHG714050411

KHG714050311

KHG714017710

KHG714036510

KHG714036710

KHG714036610

KHG714037411

BEND 45°Ø 80

INSULATED BEND 45°Ø 80

INSULATED TUBEADAPTER

AIR INLET/OUTLET FLUESOCKET KIT

AIR OUTLET FLUESOCKET KIT

INTERNAL SEALINGCOLLAR FOR INSULATEDTUBES Ø 100

DUAL FLUE VERTICALCHIMNEY TERMINAL

FLAT ROOF TILE

PITCHED ROOF TILE

TUBE Ø 80CENTRING KITPack of 5

KHG714106110

KHG714037310

KHG714018510

KHG714018411

KHG714010610

KHG714010410

CLAMPCENTRING KIT

TUBE Ø 80 SUPPORTINGBRACKETPack of 5

INTERNAL SEALINGCOLLAR Ø 80

EXTERNAL SEALINGCOLLAR Ø 80

DUAL FLUE HORIZONTALCHIMNEY TERMINAL

DUAL FLUETERMINAL Ø 80

38

Dual fl ue systems

CONDENSATECOLLECTOR KIT

Luna3models Eco3 Slim

Nuvola3ComfortNuvola3

Eco3Compact

Main Digit

Kit available for every range model. Otherwise specifi ed.

Page 39: INFO_TECH_UK 09_08

39

Flue tube for cascade installationGas condensing boilers

KHG714093211

KHW714097510

KHW714097910

KHG714093311

KHW714097610

KHW714098010

KHG714093411

KHG714111110

KHW714097410

PP FLUE TUBE KIT FORTWO BOILERS Ø 125

PP FLUE TUBE KIT FORTWO BOILERS Ø 200

PP FLUE TUBE KIT Ø 125FOR THE THIRD BOILER

PP FLUE TUBE KIT Ø 160FOR THE THIRD BOILER

PP FLUE TUBE KIT Ø 200FOR THE THIRD BOILER

PP SHUTTER KIT 110/80WITH CONDENSING TRAP

PP SHUTTER KIT 110/110WITH CONDENSING TRAP

KHG714094410

KHW714097810

KHW714098210

KHG714094510

KHG714094610

KHW714097710

KHW714098110

KHW714096910

PP 87° BEND Ø 125

PP 87° BEND Ø 160

PP 87° BEND Ø 200

PP 45° BEND Ø 125Pack of 2

PP TUBE EXTENSIONØ 125L=1000 mm

PP TUBE EXTENSIONØ 160L=1000 mm

PP TUBE EXTENSIONØ 200L=1000 mm

PP REDUCTIONØ 110/100

PP FLUE TUBE KIT FORTWO BOILERS Ø 160

Luna HT85/100 kW

Luna HT35/45/55/65 kW Power HT

Flue tube accessories

45-65

45-65

85-150

45-65

Luna3 System HT

PP SHUTTER KIT 110/110WITH CONDENSING TRAP

Kit available for every range model. Otherwise specifi ed.

Page 40: INFO_TECH_UK 09_08

40

Hydraulic system accessoriesSlim

Nuvola3ComfortNuvola3

Eco3HT Luna3models

Eco3 CompactMain Digit

KHG714028910HYDRAULIC CONNECTION KITIt includes: 5 telescopic tubes,1 gas inlet valve

KHG714032010

CONNECTION KITIt includes: 4 connections,1 Mains water valve,1 gas inlet valve

UNIVERSALREPLACEMENT KITIt includes: fi ttings and fl exiblestainless steel pipes

KHG714058810Luna3

System HTPrime HT

KHG714083810STOP VALVE KIT NUVOLA3to avoid installation water to get in contact with waterworks

KHG714023211STOP VALVE KITto avoid installation water to get in contact with waterworks

Luna3System HTPrime HT

+KHG714021911/+KHG 714052610

+KHG714021911/+KHG 714052610

+KHG714021911/+KHG 714052610

KHG714023310

VERTICAL TUBECONNECTION KITIt includes 5 tubes for verticalconnection

+KHG714028910+KHG714028910 +KHG714028910

KHG714021911Mains water VALVEWITH FILTER

KHG714052610Mains water VALVEWITHOUT FILTER

2.300Fi,2.230i,2.300i

Nuvola3 Comfort HT/

Prime Storage HT

KHG714024611HEATING SYSTEMFLOW/RETURN VALVEWITH FILTER

KHG714022011HEATING SYSTEMFLOW/RETURN VALVEWITHOUT FILTER

2.300Fi,2.230i,2.300i,

1.300Fi/FiN

Nuvola3 Comfort HT

KHG714112310

Luna3 HT Luna3

System HTPrime HT

HEATING SYSTEM VALVE

KHG714052510 GAS VALVE KIT

KHG714083910

STOP VALVE KIT STORAGE BOILERS to avoid installation water to get in contact with waterworks

Nuvola3 Comfort HT

Prime Storage HT

Kit available for every range model. Otherwise specifi ed.

KHG714110710

KHG714110810

KHG714110910

HYDRAULIC CONNECTION KIT: it includes 5 telescopic tubes, 1 Mains water valve,1 gas inlet valve

HYDRAULIC CONNECTION KIT WITH HEATING TAPS: it includes 5 telescopic tubes, 1 gas inlet valve, 1 mains water valve, 2 heating circuit valves

HYDRAULIC CONNECTION KIT FOR STORAGE BOILERS: it includes 5 telescopic tubes, 1 gas inlet valve, 1 mains water valve

Nuvola3

Blue /Max /Air

Page 41: INFO_TECH_UK 09_08

41

KHG714086311

KHG714085110

KIT FOR MIXED SYSTEMS(high and low temperature)

ADDITIONAL PUMP TOCONTROL A 3rd ZONE(2nd high temperature zone)

KHG714114210

KSL714114010

KSL714086111

KHG714085410U.B. INOX ADDITIONALEXPANSION VESSEL (4 lt)

COMBI ADDITIONALEXPANSION VESSEL (4 lt)

Completion system accessories

Luna3Comfort HT +

Combi

HT Luna3models

Eco3Nuvola3ComfortNuvola3

SlimEco3

CompactMain Digit

Luna3 System HT

Kit for Comfort HT mixed systems

Luna3Comfort HT/Nuvola3

Comfort HT

Luna3Comfort+ HT Combi

KHG714096310ELECTRIC 3 WAY KIT FOREXTERNAL CONNECTION

KHG714062210PUMP UP 15/60 AOGRUNDFOS

24/25 kW 24 kW

KHG714085210PUMP UPS 15/70 AOGRUNDFOS

31 kW

DHW SENSOR – PUMPCONNECTING CABLEKHW714087410

KHG714084810CONNECTION KIT TOINDIRECT CYLINDER (UB INOX)

Heatingonly

KHW714085610CONNECTION PUMP KITSLIM/U.B. INOX

Slimheating

only

KHG714021611 EXPANSION VESSEL (10 lt)

KHG714034410 ADDITIONAL EXPANSIONVESSEL (2 lt)

KHG714022910 FLOW RESTRICTOR

KFG714079610KIT FOR MIXED SYSTEMS(high and low temperature)

Prime HT

KHG714106610

KHG714022710 RECIRCULATING KIT

Nuvola3Comfort HT

PrimeStorage HT

Hydraulic accessories

KFG714111910

KHG714113810

Nuvola3

3 WAY VALVE MOTOR

Luna3Comfort +

Combi

UB Inox

28 kW

Heatingonly

Eco3Compact

Heatingonly

Heatingonly

Heatingonly

Eco3CompactHeating

only

3 WAY VALVE MOTOR AND HOT WATER TEMPERATURE SENSOR

COMFORT HT KIT FORMIXED SYSTEMS(high and low temperature)

ADDITIONAL PUMP TOCONTROL A 3rd ZONE

KIT FOR HANDLING A LOW TEMPERATURE ZONE

KHG714079710ADDITIONAL EXPANSIONVESSEL (2 lt)

PrimeStorage HT

KHW714096810CONNECTION KIT TOINDIRECT CYLINDER (U.B. INOX)

>35 kW

Kit for mixed systems(high and low temperature)

Kit for mixed systems

(high and low temperature)

Kit available for every range model. Otherwise specifi ed.

Page 42: INFO_TECH_UK 09_08

42

Hydraulic accessories

Luna HT35/45/55/65 kW

Luna HT85/100 kW Power HT

KHG714104510MANIFOLD PIPES SINGLEBOILER/LAST BOILER

KHG714104610MANIFOLD PIPESBOILERS IN CASCADE

HYDRAULIC CONNECTIONKIT FOR SINGLE BOILERWITH LOW LOSS HEADER

KHG714095612 35 kW

Hydraulic accessories for high effi ciency condensing boilers

KHW714103610MANIFOLD PIPESBOILER IN CASCADE(2 cm between the boilers)

KHW714099010MANIFOLD PIPESBOILERS IN CASCADE(45 cm between the boilers)

MANIFOLD PIPES SINGLEBOILER/LAST BOILER

KHW714104210

KHW714104310BOILER – MANIFOLD PIPEHYDRAULIC CONNECTION

KHW7140986112nd PUMP HYDRAULICCONNECTION

BOILER – MANIFOLD PIPEHYDRAULIC CONNECTIONSINGLE BOILER/BOILERSIN CASCADE

KHG714104410

KHG714095411

HYDRAULIC CONNECTIONSINGLE BOILER/BOILERSIN CASCADE

Luna3 System HT

KHG714117110MANIFOLD PIPES 2 SYSTEM HT BOILERS IN CASCADE

KHG714117210MANIFOLD PIPES 3rd SYSTEM HT BOILER IN CASCADE

Kit available for every range model. Otherwise specifi ed.

Page 43: INFO_TECH_UK 09_08

43

KHG714062111

KHG714062810

KHG714072511

KHG714106511

PCB INTERFACE FORREMOTE CONTROLLER

REMOTE CONTROLLERAND CLIMATIC REGULATOR (QAA73)

Sensor and thermostats

KHG714072811

Remote controllers

KHG714072612

KHG714106410 REMOTE CONTROLLER ANDCLIMATIC REGULATOR

PCB INTERFACE FORZONE CONTROL

ROOM THERMOSTAT (RT)

OUTDOOR SENSOR (QAC34)

OUTDOOR SENSOR

HT LunaHT 35/45/55/65 kW

LunaHT 85/100 kW

Power HT Luna3models

Eco3Eco3

CompactMain Digit

Nuvola3ComfortNuvola3

Slim

Prime HTPrime

Storage HT

Nuvola3

Luna3System HTPrime HT

(+KHG714072511for Prime HT)

Thermoregulation accessories

KHG714100510

KHG714086910

KHG714086810

KHG714086710

MECHANICAL ROOMTHERMOSTAT

WEEKLY TIMER AND ROOMTHERMOSTAT NICE TIME

WEEKLY TIMER AND ROOMTHERMOSTAT MAGIC TIME

KHG714061610

KHG714061710

MECHANICAL DAILYTIMER KIT

Timers

Prime HT

Prime HTDIGITAL WEEKLY TIMER

PCB FOR REMOTEALARM SIGNAL

Luna3Blue

KHG714114710

REMOTE CONTROLLER ANDCLIMATIC REGULATORWIRELESS (already included in Luna3 Comfort Air)

Kit available for every range model. Otherwise specifi ed.

Page 44: INFO_TECH_UK 09_08

44

KHG714078310

KHG714079010

KHG714061911

HOT WATER TEMPERATURESENSOR FOR RVA47 (QAZ21)

KHG714078810

Completion system accessories

KHG714078710

KHG714078610

KHG714078910

KHG714076810

Heating fl ow/returnsensor for AGU2.500 (QAD36)

HEATING FLOW/RETURNSENSOR FOR RVA46 ANDRVA47 (QAD21)

MIXING VALVE G3/4’’

MIXING VALVE G1/2’’

MIXING VALVE G1’’

KHG714078511 MOTOR FOR THEMIXING VALVE

Luna3System HT

Luna3System HT

Luna3System HT

Heating only

KHG714113910

KHG714078212

KHG714096610

KHG714107611

KHG714077913

CASCADE CONTROLLER(RVA47) It includes atemperature sensor (QAD21)

Thermoregulation controllers

KHG714078013

KHG714078112

Temperature regulator formixed systems (RVA46) itincludes a temperaturesensor (QAD21)

Boiler interface for climatic regulators RVA46 ANDRVA47 (OCI420)

BOILER CONTROLINTERFACE 0-10 V(AGU 2.511)

Boiler interface for mixed systems with two different temperature (AGU 2.500)

KHG714078410Room sensor: it can beinstalled only withRVA46 (QAA50)

Luna3System HT

Luna3System HT

Luna3 HTNuvola3 HT

Luna3System HT

Luna3System HT

Luna3System HT

Luna3System HT

Luna3System HT

INSTALLATION BOXFOR RVA CONTROLLERS

Heating only

Luna3 Comfort HTNuvola3 HT

HOT WATERTEMPERATURE SENSOR

HOT WATERTEMPERATURE SENSOR

BOILER INTERFACE FOR MIXED SYSTEMS

HT LunaHT 35/45/55/65 kW

LunaHT 85/100 kW

Power HT Luna3models Eco3

Nuvola3ComfortNuvola3

Slim

Kit available for every range model. Otherwise specifi ed.

Thermoregulation accessories

Luna3 Comfort HTNuvola3 HT

Luna3 Comfort HTNuvola3 HT

Luna3 Comfort HTNuvola3 HT

Page 45: INFO_TECH_UK 09_08

45

Other accessories

Installation templates

KHG714062010

KHG714060111

KSL714086411

KSG714088210

HT

KHG714076411

METAL TEMPLATEUB INOX 80-120

METAL TEMPLATE FORSTORAGE BOILERS

METAL TEMPLATE FORLUNA3 COMFORT / ECO3FANNED FLUE MODELS(for Luna3 Comfort, fanned andopen fl ue models)

Luna3Comfort Eco3

Nuvola3ComfortNuvola3

SlimUB Inox

Luna3System HTPrime HT

Nuvola3Comfort HT/

PrimeStorage HT

Luna3Comfort HT +

Combi

Luna3Comfort +

Combi

KHI714063310

KHI714053511

Electric water heaters

Luna3SilverSpace

KHG714073810

KHG714023011

BOTTOMCOVER

KHG714024310

POLYPHOSPHATEBATCHER

POLYPHOSPHATERECHARGEPack of 4

Other accessories

24 kW

Luna3System HTPrime HT

Luna3System HTPrime HT

KHG714024811

KHG714073410

UPPER COVER FOR OPENFLUE MODELS

UPPER COVERFOR FANNEDFLUE MODELS

Outdoor installation accessories

4 L EXPANSION VESSEL KITfor 50-100 l electric water heaters

UNIVERSAL BRACKET KIT FORHORIZONTAL WATER HEATERS

METAL TEMPLATEBOILERS FOR OUTDOORMODELS

24 kW

Eco3Compact

Main Digit

Kit available for every range model. Otherwise specifi ed.

METAL TEMPLATE

Page 46: INFO_TECH_UK 09_08

46

Other accessories

Luna Sat

DATATRANSMISSION

CONTROL

KSV714102710

KSV714103010

KSV714102810

KSV714102910

KSV714108610

NETWORK NODE

NETWORK NODE WITH GATEWAY (RS232)

NETWORK NODE WITH GATEWAY FOR TRANSMISSION VIA GSM

REMOTE READER DEVICE

SOFTWARE ACS 26

KSV714102510 FIRST VOLUMETRIC METER FOR R/1, RP/1, R2Z

KSV714102610 FIRST VOLUMETRIC METER FOR RS, RSP, RS2Z

KSV714106311 SECOND VOLUMETRIC METER FOR RP/1

THERMOREGULA-TION

MOUNTING SYSTEM

KHG714072811 QAC34: OUTDOOR SENSOR

KHG714062810 ROOM THERMOSTAT (RT)

KSV714109510 REMOTE CONTROL AND ROOM SENSOR (R2Z, RS, RSP, RS2Z, RA, RA2Z MOD.)

KHG714086710 DIGITAL CHRONOSTAT (R/1, RP/1, MOD.)

KSV714101210 METAL CASE FOR MONOZONE MODELS

KSV714101310 METAL CASE FOR 2 ZONE MODELS

INDIRECTCYLINDER KHG714108410 LUNA SAT B60 FOR RA, RA2Z, MODELS

KSV714118210 SECOND VOLUMETRIC METER FOR RP/1

KSV714110110 SECOND VOLUMETRIC METER FOR R/1, R2Z

KSV714110010 VOLUMETRIC METER FOR RA, RA2Z

KSV714114510 VOLUMETRIC METER FOR RH

KSV714114610 VOLUMETRIC METER FOR RPH

KSV714117010 METAL CASE FOR RH MODEL

Page 47: INFO_TECH_UK 09_08

47

Other accessories

LNC 710200060

LNC 710200100

LNC 710200080

FLAT ROOF FRAME KIT FOR 2 COLLECTORS

PROBE HOLDER AND HYDRAULIC CAPS

LNC 710200070

FLAT ROOF FRAME KIT FOR 1 COLLECTOR LNC 710200090

INCLINED ROOF FRAME KIT FOR 2 COLLECTORS

INCLINED ROOF FRAME KIT FOR 1 COLLECTOR

Solar collector SB20SR frames

LNC 710200030 HYDRAULIC CONNECTION KIT AMONG COLLECTORS

Collectors for forced draft installation accessories

LNC 710250050

LNC 710250060

INCLINED ROOF FIXING SYSTEM FOR ADDITIONAL SB 25 COLLECTOR *

ROOF LEVEL + 20° FIXING SYSTEM FOR ADDITIONAL SB 25 COLLECTOR

FLAT ROOF FIXING SYSTEM SB 25LNC 710250040

LNC 710250030 ROOF LEVEL + 20° FIXING SYSTEM SB 25

LNC 710250020 INCLINED ROOF FIXING SYSTEM SB 25

Solar collector SB25 frames

LNC 710250070

LNC 710250100

LNC 710250110

FIXING SYSTEM UNDER TILE FOR 2 COLLECTORS

FIXING SYSTEM UNDER TILE FOR 1 ADDITIONAL COLLECTOR*

FLAT ROOF FIXING SYSTEM FOR ADDITIONAL SB 25 COLLECTOR

LNC 710250130 HORIZONTAL SB 25 COLLECTOR FIXING SYSTEM

LNC 710250140 FIXING SYSTEM FOR HORIZONTAL SB 25 ADDITIONAL COLLECTOR *

LNC 710250080 SUPPORT FRAME FOR 1 SB 25 COLLECTOR

LNC 710250090 SUPPORT FRAME FOR 2 SB 25 COLLECTORS

LNC 710250120 SUPPORT FRAME FOR 1 HORIZONTAL SB 25 COLLECTOR

* THE ADDITIONAL COLLECTOR FIXING SYSTEMS HAS TO BE ORDERED TO INSTALL MORE THAN 2 COLLECTORS LINKED IN SEQUENCE. EX: TO INSTALL 4 COLLECTORS, IT MUST BE ORDERED: NR 1 INCLINED ROOF FiXING SYSTEM SB 25, NR 1 SUPPORT FRAME FOR 2 SB 25 COLLECTORS, NR 2 INCLINED ROOF FIXING SYSTEMS FOR ADDITIONAL SB 25 COLLECTOR AND NR 2 SUPPORT FRAMES FOR 1 SB 25 COLLECTOR.

LNC 710260010

LNC 710260050

LNC 710260060

BASIC COVERING FOR 2 SB 25 IN COLLECTORS

VERTICAL COVERING FOR 1 SB 25 IN SIDE EXTENSION

LNC 710260020

BASIC COVERING FOR 1 SB 25 IN COLLECTORLNC 710260120

FIXING SYSTEM FOR 1 SB 25 IN - SB 13 IN ADDITIONAL COLLECTOR

2 SB 25 IN - SB 13 IN COLLECTORS FIXING SYSTEM

SB25 IN - SB13 IN Solar collectors accessories

LNC 710260070

LNC 710260090 COVERING FOR INSTALLING MORE THAN 2 SB 25 IN - SB 13 IN COLLECTORS ON THE SHORT SIDE

COVERING FOR SB 25 IN - SB 13 IN UPPER EXTENSION

LNC 710130010 BASIC COVERING FOR 2 SB 13 IN COLLECTORS

LNC 710260100 BASIC COVERING FOR 2 SB 25 IN COLLECTORS TO BE INSTALLED ON PANTILE ROOVES

LNC 710130020 VERTICAL COVERING FOR SB 13 IN SIDE EXTENSION

LNC 710130030 BASIC COVERING FOR 2 SB 13 IN COLLECTORS TO BE INSTALLED ON PANTILE ROOVES

LSC 710250010

LNC 710000040

LNC 710000050

SOLAR CONTROLLER SENSOR

FLOW REGULATOR INTERFACE

LSC 710000021

COMFORT SOLAR CONTROLLERLSC 710000031

ECO SOLAR CONTROLLER

SOLAR SYSTEM CONNECTION GROUP WITH DIFFERENTIAL CONTROLLER

Other accessories

LSC 710000061

LSC 710000071

LSC 710000010

COMFORT SOLAR SYSTEM CONNECTION GROUP

NON-TOXIC ANTIFROST LIQUID*

NEUTRAL SOLAR SYSTEM CONNECTION GROUP

*MINIMUM QUANTITY THAT MAY BE ORDERED: 5 LT OR 5 LT MULTIPLES

LNC 710260110 VERTICAL COVERING FOR SB 25 IN - SB 13 IN TO BE INSTALLED ON PANTILE ROOVES

Page 48: INFO_TECH_UK 09_08

48

Wall hung and fl oor standing boilers

Page 49: INFO_TECH_UK 09_08

49

Wall hung and fl oor standing boilersProducts technical data

Page 50: INFO_TECH_UK 09_08

Wall hung and fl oor standing boilers

50

Products technical data

Page 51: INFO_TECH_UK 09_08

51

Page 52: INFO_TECH_UK 09_08

Quality

Environment

Safetyare Baxi strategic aims and

the awarded certifi cations

ensure compliance with the

specifi c regulations

The Company assumes no responsibility for any possible contents mistakes, and reserves the right to make changes

in products, due to technical or commercial demands, at any time without notice.

Baxi S.p.A. 09-08 (C)

36061 BASSANO DEL GRAPPA (VI) Italy

Via Trozzetti, 20

Tel. +39 0424 517111 - Fax: +39 0424 38089

[email protected]