General catalogueTECHNICAL INFORMATION
Info TechSeptember 2008
Baxi
2
BAXI ITALY, a Baxi Group company and one
of the leaders of the heating sector
in Europe, has a proud tradition of developing
and producing boilers and heating systems to
the highest technological standards.
For over 30 years BAXI ITALY has provided a
wide range of cutting-edge solutions,
anticipating market evolutions with particular
attention to customer needs.
Info Tech
3
Baxi has been very successful thanks to the attention
to its products quality.
Back in 1993 Baxi was awarded the ISO 9001
Certifi cation and in 2002 the ISO 9001:2000
Certifi cation in order to reach constantly the highest
levels of quality.
As Baxi recognizes environment, health and safety
protection as strategic aims, other prestigious
acknowledgements came in 2001 (ISO 14001)
and in 2004 (OHSAS 18001).
Baxi success is based on perfect agreement of all its
components, people, products and technology.
And its high quality standards
Training is a crucial issue for high effi ciency appliances
and Baxi invests consistently in providing detailed
technical data and hands-on educational courses.
The newly developed “Baxi Training Centre” welcomes
several thousand people every year.
4
GuidelinesIn order to complete all the product commercial details, Info Tech goes
deep into technical aspects of the wide range of Baxi boilers and high
technology heating systems.
In this catalogue the specifi c technical sections have been divided into
product categories. For each section technical drawings and
accessories are divided by product range.
In the commercial catalogue (INFO COMM)
Technical
drawings
Graphs
Flue systems
Flue tube
accessories
Hydraulic
accessories
Thermo-
regulation
accessories
Other
accessories
In the commercial catalogue we show the complete range of BAXI
products. On each page in addition to the product benefi ts,
there are a detailed list of the appliance characteristics,
a technical chart, and coloured icons, referring to the specifi c
pages of this technical manual.
General catalogueCOMMERCIAL INFORMATION
Info CommSeptember 2008
Info Tech
5
Index
Technical drawings
Graphs
Flue systems
Condensing gas boilers pag. 6
Gas boilers pag. 9
High effi ciency condensing systems pag. 15
Flue systems pag. 20
Solar collectors pag. 30
Indirect cylinders pag. 31
Electric water heaters pag. 32
Gas water heaters pag. 33
Flue tube accessories pag. 34
Hydraulic accessories pag. 40
Thermoregulation accessories pag. 43
Other accessories pag. 45
Products technical data pag. 48
6
Luna3 Comfort HT240, 280, 330,1.120, 1.240, 1.280
MR Heating system fl ow G 3/4”US DHW outlet G 1/2” (for heating only models storage tank fl ow G 3/4”)GAS Gas inlet G 3/4”ES Mains water G 1/2”RR Heating system return G 3/4”SC Condensing trap possible to connect on a pipe Ø 21A Boiler hanging points. Distance between hanging points: 425 mmB Distance between hanging points and hydraulic connection
Condensing gas boilers
1 DHW outlet G 1/2”2 Mains water G 1/2”3 Heating system return G 3/4” 4 Heating system fl ow G 3/4”5 Gas inlet G 3/4”SC Condensing trap
Nuvola3 Comfort HT240, 330
177 Luna3 Comfort HT 1.120
I speedII speed
III speed
HE
AD
mH
2O
FLOW RATE (l/h)
Luna3 Comfort HT 240 - 1.240 - 280
I speed.II speed.
III speed.
HE
AD
mH
2O
FLOW RATE (l/h)
Luna3 Comfort HT 1.280 - 330
I speed.II speed.
III speed.HE
AD
mH
2O
FLOW RATE (l/h)
Nuvola3 Comfort HT 240
I speed. II speed.III speed.
HE
AD
mH
2O
FLOW RATE (l/h)
Nuvola3 Comfort HT 330
I speed.II speed.
III speed.HE
AD
mH
2O
FLOW RATE (l/h)
SC
bottom view
7
Technical drawings - graphs - fl ue systems
A Heating system fl ow G 3/4” MB Heating system return G 3/4” MC Gas supply pipe G 3/4” ME Mains water G 1/2” MF DHW outlet G 1/2” MG DHW recirculation G 1/2” MH Flue condensation runoffI Relief valve outlet
Luna3 Comfort HT + Combi120, 240, 330
Luna3 Comfort HT+Combi 120
I speed.
II speed. III speed.
HE
AD
mH
2O
FLOW RATE (l/h)
Luna3 Comfort HT+Combi 240
I speed.II speed.
III speed.
HE
AD
mH
2O
FLOW RATE (l/h)
Luna3 Comfort HT+Combi 330
I speed.II speed.
IIIspeed.H
EA
D m
H2O
FLOW RATE (l/h)
side view back view view from abovefrontal view
Luna3 Comfort HT 240 SolarLuna3 Comfort HT Solar - heating system circuit
I speed.II speed.
III speed.HE
AD
mH
2O
FLOW RATE (l/h)
Luna3 Comfort HT Solar
I speed. II speed.III speed.
HE
AD
mH
2O
FLOW RATE - Solar circuit
frontal view side view back view
A DHW relief valve outlet G 1/2”B Mains water G 1/2”C DHW recirculation G 1/2” D DHW outlet G 1/2”E Heating system fl ow G 3/4”F Gas supply pipe G 3/4”G Heating system return G 3/4”H Solar relief valve outlet G 1/2”I Collector inlet G 3/4”L Collector outlet G 3/4”
2056
600 640
273 433,5
89
103
95
600273
95 130 130
9085 95 90
190 65105
832
760
415
E F G
A B C D
H I L
8
Condensing gas boilersPrime HT1.120, 1.240, 240, 280, 330
MR Heating system fl ow G 3/4”US DHW outlet G 1/2” (for heating only models storage tank fl ow G 3/4”)GAS Gas inlet G 3/4” ES Mains water G 1/2” RR Heating system return G 3/4”SC Condensing trap possible to connect on a pipe Ø 21A Boiler hanging points. Distance between hanging points: 425 mmB Distance between hanging points and hydraulic connection
Prime Storage HT 240
Prime HT + Combi240
side viewfrontal view back view view from above
Prime Storage HT 240
HE
AD
mH
2O
FLOW RATE (l/h)
Prime HT + Combi 240
HE
AD
mH
2O
FLOW RATE (l/h)
bottom viewSC
A Heating system fl ow G 3/4” MB Heating system return G 3/4” MC Gas supply pipe G 3/4” ME Mains water G 1/2” M
F DHW outlet G 1/2” MG DHW recirculation G 1/2” MH Flue condensation runoffI Relief valve outlet
1 DHW outlet G 1/2”2 Mains water G 1/2”3 Heating system return G 3/4”4 Heating system fl ow G 3/4”5 Gas inlet G 3/4”SC Condensing trap
Prime HT 1.240 - 240 - 280
HE
AD
mH
2O
FLOW RATE (l/h)
Prime HT 1.120 - HT 330
HE
AD
mH
2O
FLOW RATE (l/h)
9
Technical drawings - graphs - fl ue systems
Luna3 Comfort240 Fi, 310 Fi, 1.240 Fi, 1.310 Fi
Luna3 Comfort240 i, 1.240 i
MR Heating system fl ow G 3/4”US DHW outlet G 1/2” (for heating only models storage tank fl ow G 3/4”)GAS Gas inlet G 3/4”ES Mains water G 1/2”RR Heating system return G 3/4”A Boiler hanging points. Distance between hanging points: 425 mmB Distance between hanging points and hydraulic connection
Gas boilersLuna3 Comfort 310 Fi - 1.310 Fi
HE
AD
mH
2O
FLOW RATE (l/h)
Luna3 Comfort 240 i - 1.240 i - 1.240 Fi - 240 Fi
HE
AD
mH
2O
FLOW RATE (l/h)
Luna3 Comfort Air250 Fi, 310 Fi
MR Heating system fl ow G 3/4”US DHW outlet G 1/2”GAS Gas inlet G 3/4”ES Mains water G 1/2”RR Heating system return G 3/4”A Boiler hanging points. Distance between hanging points: 425 mmB Distance between hanging points and hydraulic connection
Luna3 Comfort Air 250 Fi - 310 Fi
HE
AD
mH
2O
FLOW RATE (l/h)
10
Luna3 Blue 240 Fi - 1.240 Fi
II speed.III speed.
Luna3 Blue 280 Fi
I speed.II speed.
IIIspeed.
Luna3 Blue240 Fi, 280 Fi, 1.240 Fi
Luna3 Blue180 i, 240 i, 1.180 i
188100 C
Gas boilers
Luna3 Blue 180 i - 1.180 i - 240 i
II speed.III speed.
HE
AD
mH
2O
FLOW RATE (l/h)
HE
AD
mH
2O
FLOW RATE (l/h)
HE
AD
mH
2O
FLOW RATE (l/h)
MR Heating system fl ow G 3/4”US DHW outlet G 1/2” (for heating only models storage tank fl ow G 3/4”)GAS Gas inlet G 3/4”ES Mains water G 1/2”RR Heating system return G 3/4”
A Boiler hanging points. Distance between hanging points: 425 mmB Distance between hanging points and hydraulic connectionC Ø 110 180 i – 1.180 i Ø 130 240 i
Luna3 Comfort + Combi240 Fi, 310 Fi
A Heating system fl ow G 3/4” MB Heating system return G 3/4” MC Gas supply pipe G 3/4” ME Mains water G 1/2” MF DHW outlet G 1/2” MG DHW recirculation G 1/2” MH Flue condensation runoffI Relief valve outlet
Luna3 Comfort + Combi 310 Fi - 240 Fi
HE
AD
mH
2O
FLOW RATE (l/h)
view from aboveside viewfrontal view back view
11
Technical drawings - graphs - fl ue systems
Luna3 Comfort Max 250 Fi, 310 Fi
Luna3 Comfort Max 240 i
Nuvola3 Comfort140 Fi, 240 Fi, 280 Fi, 320 Fi
Nuvola3 Comfort240 i, 280 i
1 DHW outlet G 1/2”2 Mains water G 1/2”3 Heating system return G 3/4”4 Heating system fl ow G 3/4”5 Gas inlet G 3/4”
Luna3 Comfort Max 310 Fi
I speed.II speed.
III speed.HE
AD
mH
2O
FLOW RATE (l/h)
Luna3 Comfort Max 240 i - 250 Fi
II speed.III speed.
HE
AD
mH
2O
FLOW RATE (l/h)
Nuvola3 Comfort 140 Fi - 240 Fi/i
HE
AD
mH
2O
FLOW RATE (l/h)
Nuvola3 Comfort 280 Fi/i - 320 Fi
HE
AD
mH
2O
FLOW RATE (l/h)
MR Heating system fl ow G 3/4”US DHW outlet G 1/2”GAS Gas inlet G 3/4”ES Mains water G 1/2”RR Heating system return G 3/4”
A Boiler hanging points. Distance between hanging points: 425 mmB Distance between hanging points and hydraulic connection
bottom view
Ø100
12
Gas boilersNuvola3140 B40 Fi, 240 B40 Fi, 280 B40 Fi
Nuvola3240 B40 i, 280 B40 i
1 DHW outlet G 1/2”2 Mains water G 1/2”3 Heating system return G 3/4” 4 Heating system fl ow G 3/4”5 Gas inlet G 3/4”
Nuvola3 140 B40 Fi - 240 B40 Fi-i
Nuvola3 280 B40 Fi-i
Luna3 Silver Space250 Fi, 310 Fi
Luna3 Silver Space 250 Fi - 310 Fi
MR Heating system fl ow G 3/4”US DHW outlet G 1/2”GAS Gas inlet G 3/4”ES Mains water G 1/2”RR Heating system return G 3/4”A Boiler hanging points. Distance between hanging points: 524 mmB Distance between hanging points and hydraulic connection
HE
AD
mH
2O
FLOW RATE (l/h)
HE
AD
mH
2O
FLOW RATE (l/h)
HE
AD
mH
2O
FLOW RATE (l/h)
bottom view
Ø100
13
Technical drawings - graphs - fl ue systems
Eco3240 Fi,280 Fi,1.240 Fi
Eco3240 i1.240 i
100 120
Eco3 Compact240 Fi, 1.140 Fi, 1.240 Fi
Main Digit240 Fi
Eco3 Compact 240 Fi - 1.140 Fi - 1.240 Fi - 240 i - 1.140 i - 1.240 i
HE
AD
mH
2O
FLOW RATE (l/h)
Main Digit 240 Fi - 240i
HE
AD
mH
2O
FLOW RATE (l/h)
MR Heating system fl ow G 3/4”US DHW outlet G 1/2” (for heating only models storage tank fl ow G 3/4”)GAS Gas inlet G 3/4”
ES Mains water G 1/2”RR Heating system return G 3/4”A Boiler hanging points. Distance between hanging points: 425 mmB Distance between hanging points and hydraulic connections
Eco3 Compact240 i, 1.140 i, 1.240 i
Main Digit240 i
MR Heating system fl ow G 3/4”US DHW outlet G 1/2”GAS Gas inlet G 3/4”
ES Mains water G 1/2”RR Heating system return G 3/4”
MR Heating system fl ow G 3/4”US DHW outlet G 1/2” (for heating only models storage tank fl ow G 3/4”)
GAS Gas inlet G 3/4”ES Mains water G 1/2”RR Heating system return G 3/4”
frontal view frontal viewside view side view bottom view
MR US GAS ES RR
Eco3 280 Fi
HE
AD
mH
2O
FLOW RATE (l/h)
Eco3 240 Fi - 1.240 Fi - 240 i - 1.240 i
HE
AD
mH
2O
FLOW RATE (l/h)
bottom view
MR US GAS ES RR
70 65 65 65 65 70
12
0,5
400
frontal view side view
400
73
3
22
317
47
frontal view side view
Ø 122186,6
400 317
78
2
62
81
02
52
400
317
47
22
73
3
400 317
Ø 122186,6
78
2
62
81
02
52
70 65 65 65 65 70
400
14
1,2
14
Gas boilersSlim1.230 Fi, 1.300 Fi
Slim1.230 FiN, 1.300 FiN
Slim 2.300 Fi - 2.230 i - 2.300 i - 1.150 i
1.230 i - 1.300 i - 1.230 Fi - 1.300 Fi
0 0,2 0,4 0,6 0,8 1,0 1,2 1,4 1,6 1,8 2,0 2,2 2,4
I speed. II speed. III speed.
Slim1.150 i, 1.230 i,1.300 i
Slim1.230 iN,1.300 iN
Slim1.400 iN, 1.490 iN, 1.620 iN
frontal view side view frontal view side view back view
Slim2.300 Fi
Slim2.230 i, 2.300 i
back view back view side view frontal view
A Heating system fl ow G 3/4” MB Heating system return G 3/4” MC Gas supply pipe G 1/2” MD Mains water G 1/2” ME DHW outlet G 1/2” MF Recirculation G 1/2” M (Slim 2.260 Fi) Recirculation G 1/2” F (Slim 2.230 i, 2.300 Fi)
HE
AD
mH
2O
FLOW RATE (l/h)
frontal view side view back view back viewside view
AA
B
B
C C
520 - 600
481 - 564596 - 676
350
85
0
116 119 115542 - 622
520 - 600
481 - 561
507 - 587
A Heating system fl ow G 3/4” MB Heating system return G 3/4” MC Gas supply pipe G 1/2” M
L1
L2
L1
Slim 1.150i 520
Slim 1.230i 600
Slim 1.300i 680
dimensions (mm)
H L2
Slim 1.230iN 600 600
Slim 1.300iN 680 680
Slim 1.400iN 1490 635
Slim 1.490iN 1490 715
Slim1.620iN 1650 875
dimensions (mm)
sug
ge
ste
d 1
40
0
horizontal
GAS connection
15
Technical drawings - graphs - fl ue systems
MR Heating system fl ow G 3/4”MB Storage tank fl ow G 3/4”GAS Gas inlet G 3/4”ES Mains water G 1/2”RR Heating system return G 3/4”SC Condensing trap possible to connect on a pipe Ø 21A Boiler hanging points. Distance between hanging points: 425 mmB Distance between hanging points and hydraulic connection
Luna3 System HT1.180 MP, 1.240 MP, 1.330 MP*
Luna3 System HT 1.240 MP
maxspeedmin
speed
Luna3 System HT 1.180 MP
max speed
minspeed
Luna3 System HT 1.330 MP
maxspeed
minspeed
Luna HT (commercial applications)1.350, 1.450, 1.450P,1.550, 1.650
High effi ciency condensing systems
MB
HE
AD
mH
2O
FLOW RATE (l/h)
HE
AD
mH
2O
FLOW RATE (l/h)
HE
AD
mH
2O
FLOW RATE (l/h)
Luna HT 1.350-1.450-1.450P-1.550-1.6507000
6000
5000
4000
3000
2000
1200
0 1000 2000 3000 4000 5000
HE
AD
mH
2O
FLOW RATE (l/h)
Luna HT 1.350-1.450-1.450P-1.550-1.650
1000 2000 3000 4000 5000 6000
Exc
ha
ng
er
pre
ssu
re d
rop
mH
2O
FLOW RATE (l/h)
I speedII speed III speed
sug
ge
ste
d 1
40
09
50
GAS Gas inlet G 3/4”MR Heating system fl ow G 1”RR Heating system return G 1”SC Condensing trap possible to connect on a pipe Ø 21
*Luna3 System HT boilers are connectable to Combi 80 lt
16
High effi ciency condensing systems
GAS Gas inlet G 3/4”MR Heating system fl ow G 1-1/2”RR Heating system return G 1-1/2”SC Condensing trap possible to connect on a pipe Ø 21
horizontal
GAS connection
Luna HT 1.850-1.10009
8
7
6
5
4
3
2
1
0 1000 2000 3000 4000 5000 6000 7000 8000 9000
HE
AD
mH
2O
FLOW RATE (l/h)
Luna HT 1.850-1.1000
1000 2000 3000 4000 5000 6000
FLOW RATE (l/h)
Exc
ha
ng
er
pre
ssu
re d
rop
mH
2O
Luna HT (commercial applications)1.850-1.1000
17
Technical drawings - graphs - fl ue systems
Cabinets with 2condensing higheffi ciency boilers
Luna HT45-55-65 kW
Luna HT85-100 kW
Luna HT45-55-65 kW
Luna HT85-100 kW
Ø149
19
00
19
0
1600
800
309 160 33177
22
8
417
124
29
01
94
445 800 355
27
7,5
454,5 800 345,5
18
2,5
Ø149
19
00
19
0
2400800
309 160 33177
22
8
417
124
29
01
94
445 800 800 355
27
7,5
454,5 800 800 345,5
18
2,5
Cabinets with 3condensing higheffi ciency boilers
Dimensions (mm)
W H D
2 doors 1600 1900 800
Dimensions (mm)
W H D
3 doors 2400 1900 800
18
High effi ciency condensing systemsPower HT1.450-1.6501.850-1.10001.1200-1.1500
(*) 450 mm or 20 mm between boilers in cascade depending on manifold accessory used
Power HT 1.450-1.650
1000 1500 2000 2500 3000 3500 4000
Exc
ha
ng
er
pre
ssu
re d
rop
mH
2O
Power HT 1.850 - 1.1000
2000 3000 4000 5000 6000
Exc
ha
ng
er
pre
ssu
re d
rop
mH
2O
Power HT 1.1200-1.1500
3000 4000 5000 6000 7000 8000 9000
Exc
ha
ng
er
pre
ssu
re d
rop
mH
2O
45 cm
45 cm/2 cm
45 cm/2 cm
Power HT 1.450-1.650-1.850-1.1000-1.1200-1.15009
8
7
6
5
4
3
2
1
0 1000 2000 3000 4000 5000 6000 7000 8000 9000
HE
AD
mH
2O
Power HT 1.1500 1.1200 1.1150 1.1000 1.850 1.650 1.450
Depth (A) mm 1132 1024 1024 871 801 693 621
RVA positioning
FLOW RATE (l/h)
FLOW RATE (l/h)
FLOW RATE (l/h)
FLOW RATE (l/h)
GAS Gas inlet G 3/4”
MR Heating system fl ow G 1-1/2”
RR Heating system return G 1-1/2”
19
Disegni tecnici dimensionali - grafi ci portata prevalenza Technical drawings - graphs - fl ue systems
Models: Luna Sat R/1 - RP/1 - RS - RSP - RA
Models: Luna Sat R2Z - RS2Z - RA2Z
above view
case width 800
above view
case width 600
LegendaCentralized system connectionsIP: primary inlet from centralized system G 3/4’’ MUP: primary outlet to centralized system G 3/4’’ M
Heating system connections – single zone modelsMR: heating G 3/4” M system fl owRR: heating G 3/4” M system return
Heating system connections – double zone modelsMRAT: high temperature G 3/4’ M system fl ow(R2Z and RS2Z models)MRBT: low high temperature G 3/4” M system fl ow(R2Z and RS2Z models)RRAT: high temperature G 3/4” M system return(R2Z and RS2Z models)RRBT: low temperature G 3/4” M system return(R2Z and RS2Z models)
DHW system connectionsES (*): Mains water G 1/2” M (RS, RSP, RS2Z models)US: DHW outlet G 1/2” M (RS, RSP, RS2Z models)
DHW consumption meter connectionsESC1 (*): Mains water to heat meter G 3/4” MES (*): DHW outlet fi rst volumetric meterESC2 (*): Mains water to the second heat meter G 3/4” M(R, RP, R2Z models)US(*):DHW outlet second volumetric meterUSC: volumetric meter outlet (RH model)
(*) in case of installation of the volumetric meter (available as optional) the Mains water has to be transferred in the hydraulic connection ESC1 (o ESC2)
Models: Luna Sat RH
above view
case width 650
USC USC
Models: Luna Sat R/1 - RP/1
screw seatsconnection tongues
frontal view
L 600
con
ne
ctio
n k
it 3
0
case width 150
left side view
H c
ase
65
0
38
,5 50
50
64
Models: Luna Sat R2Z - RS2Z - RA2Z
screw seatsconnection tongues
frontal view
L 800
con
ne
ctio
n k
it 3
0
case width 150
left side view
H c
ase
75
0
38
,5 50
50
64
Models: Luna Sat RS - RSP - RA
case width 150
left side view
H c
ase
65
0
38
,5 50
50
64
screw seatsconnection tongues
frontal view
L 600
con
ne
ctio
n k
it 3
0
Models: Luna Sat RH
con
ne
ctio
n k
it 3
0
frontal view
P case 150
H c
ase
65
0
left side view On all the case sides there are holes dedicated to the hydraulic connections.
20
Coaxial fl ue systemLuna3 Comfort HT - Nuvola3 Comfort HT - Luna3 Comfort HT + CombiLuna3 Comfort HT Solar - Prime HT - Prime Storage HT - Prime HT + Combi
■ Ø 60/100 mm ■ Ø 80/125 mm
Prime HT + Combi
Luna3 Comfort HT Nuvola3 Comfort HT
frontal view side view
220
11
7 m
in
600
239
466
Prime Storage HTPrime HT
frontal view side view
177 140,5
450 345
12
7 m
in
frontal view side view
220 239
600 466
L max= 9 mL max= 9 m
L max= 10 m L max= 10 m
24 m24 m
25 m 25 m
L max= 10 m
99
8
34
5
99
8
40
5
L max= 10 m L max= 9 m
99
8
34
5
L max= 8 m
99
8
34
5
LAS chimney
L max= 10 m L max= 10 m25 m25 m
23 m24 m25 m25 m
LUNA3 COMFORT HT
NUVOLA3 COMFORT HT
LUNA3 COMFORT HT SOLAR 10 25 1 0,5
LUNA3 COMFORT HT + COMBI
PRIME HT
PRIME STORAGE HT
PRIME HT + COMBI
Tubes maximum length (m)
Ø 60/100 Ø 80/125
Length reductionfor a 90°
bend insertion (m)
Length reductionfor a 45°
bend insertion (m)
frontal view side view
177 140,5
450 345
12
7 m
in
Luna3 Comfort HT + Combi
frontal view
450
side view
550
346177
12
7 m
in
frontal view
450
side view
550
346177
12
7 m
in
Luna3 Comfort HT Solar
frontal view
600
273
side view
640
433,5
11
2 m
in
11
7 m
in
21
Luna3 Comfort - Luna3 Comfort + Combi - Luna3 Comfort Air - Luna3 BlueLuna3 Comfort Max - Luna3 Silver Space - Eco3 - Eco3 Compact - Main Digit
Eco3 Compact - Main Digit
view from above side view frontal view side view side view
132400
317
4786
24
85
73
3
22
63
view from above
L maxL max
L maxL max
L max L max
LAS chimney
34
5
99
8
L max
99
8
34
5
L max
99
8
34
5
L max
99
8
40
5
L max
Luna3 Comfort - Luna3 Comfort AirLuna3 Blue - Luna3 Comfort Max - Eco3
side view
345
frontal view
14
3 m
in
450
188100
Luna3 Silver Space
100 76
226 324 250
14
3 m
in
side viewfrontal view
Luna3 Comfort + Combi
frontal view
450
100
14
3 m
in
side view
550
398
Technical drawings - graphs - fl ue systems
Horizontal Luna3 - Eco3 24/25 kW 5 9
fl ue Luna3 - Eco3 28/31 kW 4 8
Luna3 Blue 4 -
Eco3 Compact/Main Digit 5 - 1 0,5
Vertical Luna3 - Eco3 4 10
chimney Luna3 Blue 4 -
Eco3 Compact/Main Digit 4 -
Tubes maximum length (m)
Ø 60/100 Ø 80/125
Length reductionfor a 90°
bend insertion (m)
Length reductionfor a 45°
bend insertion (m)
Lmax can change according to the fl ue type. See the instruction manual.
22
Coaxial fl ue systemNuvola3 Comfort - Nuvola3
frontal view
100
side view
150
424 176 466
12
0 m
in.
L max
99
8
34
5
L max
99
8
40
5
L max
99
8
34
5
L max
34
5
99
8
L max
L max
L max L max
L max L max
LAS chimney
Slim
L max= 5 m
L max= 3 m
L max= 3 m
L max= 4 mL max= 4 m
Flue lass
L max= 3 mL max= 3 m
L max= 4 m
99
8
34
5
L max= 4 m
99
8
40
5
L max= 3 m
99
8
34
5
L max= 3,5 m
99
8
34
5
Horizontal 24/28 kW 4 8
fl ue 14 kW 5 8
32 kW 3 8 1 0,5
Vertical 4 -
chimney
Tubes maximum length (m)
Ø 60/100 Ø 80/125
Length reductionfor a 90°
bend insertion (m)
Length reductionfor a 45°
bend insertion (m)
Slim 2.300 Fi
above view
100
10
2 m
in.
416234
side view
102 min.
10
0
Slim 1.230 Fi/FiN, 1.300 Fi/FiN
10
2 m
in.
above view
100
116234
side view
102 min.
10
0
5 1 0,5 60 - 100
Tubesmaximum
length(m)
Length reduc-tion for a 90°
bend insertion (m)
Length reduc-tion for a 45°
bend insertion (m)
Ø fl uemm
23
Luna3 System HT - Luna HT (from 35 kW to 100 kW) single installation
L max L max
L max L max
L max L max
LAS chimney
L max
34
5
99
8
L max
99
8
34
5
L max
99
8
40
5
L max
34
5
99
8
Luna3 System HT 10 25 -
Luna HT 35/45/55/65 kW - 10 - 1 0,5
Luna HT 85/100 kW - - 10
Tubes maximum length (m)
Ø 60/100 Ø 80/125
Length reductionfor a 90°
bend insertion (m)
Length reductionfor a 45°
bend insertion (m)Ø 110/160
Luna3 System HT
12
7 m
in.
frontal view side view
450
= =
345
186
frontal view side view
600 650
131245,5
27
0 m
in.
Luna HT 1.850 - 1.1000
frontal view side view
600 466
255
11
9 m
in.
226
Luna HT 1.350 - 1.450 - 1.450P1.550 - 1.650
Technical drawings - graphs - fl ue systems
24
Dual fl ue systemLuna3 Comfort HT - Nuvola3 Comfort HT - Luna3 Comfort HT + Combi Luna3 Comfort HT Solar - Prime HT - Prime Storage HT - Prime HT + Combi
Installation with Terminal Ø 60
30 3 1,25
Installation with Terminal Ø 80 80 0,5 0,25
Installation with Chimney Terminal 15 0,5 0,25
Tubes maximumlength (m)
Length reduction for a 90°bend insertion (m)
Length reduction for a 45°bend insertion (m)
L1 = FLUE PIPE / L2 = INTAKE PIPE
L1 L2 L2 L1 L max 960
300
15
11
50
50
0
14
50
0 11
50
Luna3 Comfort HT
110
frontal view side view
120 110
177
15
9 m
in.
140,5
345
Nuvola3 Comfort HT
frontal view side view
600 466
11041
110
14
9 m
in.
239
126
frontal view side view
600 466
11041
110
14
9 m
in.
239
126
Prime Storage HT
Luna3 Comfort HT Solar Prime HT
110
frontal view side view
120 110
177
15
9 m
in.
140,5
345
Prime HT + Combi
Luna3 Comfort HT + Combi
110
frontal view side view
120 110
177
15
9 m
in.
346
550
110
frontal view side view
120 110
177
15
9 m
in.
346
550
frontal view side view
110 120 110
15
9 m
in.
433,5
327
450 450
450600 640
450
25
Technical drawings - graphs - fl ue systems
Flexible ducting systems gas condensing boilers
26
Dual fl ue systemLuna3 Comfort - Luna3 Comfort Air - Luna3 Comfort + Combi - Luna3 Blue - Luna3 Comfort MaxLuna3 Silver Space - Eco3 - Eco3 Compact - Main Digit
L
50
0 11
50
11
50
50
0
L
L1 L2 L2 L1
side view
188
345
frontal view
94
frontal view
94 94 94
120 120
450 45014
3 m
in
14
3 m
in
frontal view side viewfrontal view
14
3 m
in
94 94 94 94
120226 324
120226 324 250
14
3 m
in
Luna3 Comfort - Luna3 Comfort Air - Luna3 Blue Luna3 Comfort Max - Eco3
Luna3 Silver Space
Eco3 Compact - Main Digit
960
300
L
2734
149
68
92
53
149
68
53 92
3427
above view frontal view side view side view frontal view above view
If the pipe length is longer than 6 meters you have to install the condensation storage kit.
(L1+L2) MAX m 40 25 20 40 25 30 30 (G20) - 25 (G31) 25
L2 MAX m 10 10 10 10 10 10 10 10
*B22 - - - - - - 25 22
Luna3 Comfort
25 kW 31 kW
Luna3Blue
Eco3
24 kW 28 kW
Eco3Compact
Main Digit
Luna3 Silver Space*
25 kW 31 kW
Luna3 Comfort Eco3
L MAX m 10 8 10 10 8 10
25 kW 31 kW
Luna3Blue
Eco3Compact
Main Digit24 kW 28 kW
L MAX m 15 12 10 15 12 12
Luna3 Comfort
25 kW 31 kW
Luna3Blue
Eco3 Eco3Compact
Main Digit24 kW 28 kW
L MAX m 14 10 9 14 10 10
Luna3 Comfort
25 kW 31 kW
Luna3Blue
Eco3 Eco3Compact
Main Digit24 kW 28 kW
INSTALLATION WITH TERMINAL Ø 60 30 3 1,25
INSTALLATION WITH TERMINAL Ø 80 80 0,5 0,25
INSTALLATION WITH CHIMNEY TERMINAL 15 0,5 0,25
TUBES MAXIMUMLENGTH (m)
LENGTH REDUCTION FOR A 90° BENDINSERTION (m)
LENGTH REDUCTION FOR A 45° BENDINSERTION (m)
side view
550
398
Luna3 Comfort + Combi
frontal view
94
frontal view
94 94 94
120 120
450 45014
3 m
in
14
3 m
in
27
Technical drawings - graphs - fl ue systems
Nuvola3 Comfort - Nuvola3
Slim
L1 L2 L2 L1 960
3005
00 1
15
0
L m
ax=
5,5
m
50
01
15
0
L max=4,5 m
FLUE PIPE (L1) MAXIMUM LENGTH WITH A 90° BEND: 10 m.
INTAKE PIPE (L2) MAXIMUM LENGTH WITH A 90° BEND: 10 m.
L2
L1960
300
L
65
01
15
0L L
11
50
65
0
Installation withproof terminal
20 0,5 0,25 80
Installation withchimney terminal
6 0,5 0,25 133
Tubes maximumlength (m)
Length reduction for a90° bend insertion (m)
Length reduction for a45° bend insertion (m)
Ø Flue (mm)
97 97
119
115 235
above view
10
1,5
min
above view
97 97
119
234 416
10
1,5
min
Slim 1.230 Fi/FiN, 1.300 Fi/FiN
Installation with 0,5 0,25 80proof terminal
Installation with 0,5 0,25 133chimney terminal
Length reduction for a 90° bend insertion (m)
Length reduction for a 45° bend insertion (m)
Ø Flue(mm)
153 120
side viewfrontal view
94 94
13
5 m
in.
Slim 2.300 Fi
28
Dual fl ue systemLuna3 System HT (single installation)
LENGTH REDUCTION FOR A 90° BEND
INSERTION (m)
LENGTH REDUCTION FOR A 45° BEND
INSERTION (m)
0,5 0,25
INTAKE PIPE MAXIMUM LENGTH: 15 m
Luna HTfrom 35 to 100 kW(single installation)
LENGTH REDUCTION FOR A 90° BEND
INSERTION (m)
LENGTH REDUCTION FOR A 45° BEND
INSERTION (m)
0,5 0,25
INTAKE PIPE MAXIMUM LENGTH: 15 m
110
frontal view side view
120 110 186
15
9 m
in.
450
345
144
frontal view side view
255 226
11
2 m
in.
11
2 m
in.
600 D
Luna HTfrom 85 to 100 kW(single installation)
INTAKE PIPE MAXIMUMLENGTH: 7 m
170
frontal view side view
245,5 131
21
4
23
0
600 650
L1
(L1+L2) max= 80 m L max= 15 m
L max= 15 m L max= 14 m
L2 L
L
L
L max= 15 m
L L1 L2
L
L
L1 L2
(L1+L2) max= 60 m (L1+L2) max= 27 mL max= 15 m L max= 14 m
29
Technical drawings - graphs - fl ue systems
Power HT
Cascade installationLuna3 System HT
Luna HT(commercial applications)
30
Collectors for forced draft installationSB 25 SB 25 IN
SB 13 IN
Collectors for natural draft installation
SB 20
Optimum volume percentage of non-toxic antifrost liquid
(SB 25, SB 25 IN, SB13 IN)
Non-toxic antifrost Freezing point
23 -10°C
32 -15°C
37 -20°C
Optimum volume percentage of non-toxic antifrost liquid
Non-toxic antifrost Freezing point
23 -10°C
32 -15°C
37 -20°C
SB 20 SR
SB 21
h x w x d (mm)
SB 20 1947 982 95
SB 21 1230 1170 95
h x w x d (mm)
SB 25 2150 1170 83
SB 25 IN 2058 1227 105
SB 13 IN 1015 1227 105
SB 20 SR 1947 982 95
Dimensions referred to a single collector
SB 20 effi ciency collector with G=800 W/m2
SB 21 effi ciency collector with G=800 W/m2
SB 25 E SB 25 IN Collectors effi ciency with G=800 W/m2
Absorber
Absorber
Absorber
200 LT 300 LT 400 LT 500 LT 800 LT 1000 LT 1500 LT 1000 LT
31
Indirect cylinder
Technical drawings - graphs - fl ue systems
LUNA UB INOXLUNA UB 80, 120
SLIM UB INOXSLIM UB 80, 120
45-120 45-120450 - 600
UB 200 SC/DC,UB 300 SC/DC,UB 400 SC/DC
UB 500 DC, UB 800 DC,UB 1000 SC/DC,UB 1500 DC,UB 2000 SC
UBTT 1000,UBPT 1000,UBPU 1500 SC
UB 200 SC/DC 1310x600
UB 300 SC/DC 1780x600
UB 400 SC/DC 1575x740
UB 500 DC 1805x760
UB 800 DC 1905x990
UB 1000 SC 2155x940
Dimensions (mm) H x Ø
UB 1000 DC 2155x990
UB 1500 DC 2285x1200
UB 2000 SC 2520x1300
UBTT 1000 2090x990
UBPT 1000 2110x1030
UBPU 1500 SC 2150x1200
Dimensions (mm) H x Ø
Luna 3 Comfort HT + Combi
1.120-1.240-1.280 models
+ =
Luna3 Comfort + Combi
1.240 Fi - 1.310 Fi - 1.240 i models
+ =
Prime HT + Combi
1.120 -1.240 models
+ =
Luna3 System HT + Combi
1.180 MP-1.240 MP-1.330 MP models
+ =
A Connection heating system fl ow/indirect cylinder 3/4”MB Connection indirect cylinder
return/heating system 3/4” M
C Mains water 1/2” M D Domestic hot water outlet 1/2” ME Relief valve 1/2” FF Recirculation 1/2” M
SOLUTIONS WITH COMBI 80 lt
Combi 879x450x550
Luna3 Comfort HT + Combi 1642x450x550
Luna3 System HT + Combi 1642x450x550
Prime HT + Combi 1642x450x550
Luna3 Comfort + Combi 1642x450x550
Dimensions (mm) h x w x d
32
Electric water heaters
upright 50/80/100 lt
horizontal 80/100 lt
H H1
50 lt upright 520 360
80 lt upright 760 565
100 lt upright 920 760
80 lt horizontal 760 395
100 lt horizontal 920 555
dimensions (mm)
10 lt 15 lt
A 267 350
B 250 310
C 70 100
D 128 168
dimensions (mm)
STORAGE
upright 30 lt
10-15 lt, ABOVE AND UNDER SINK
H H1 H
2
50 lt upright TD/TS 520 360 165
80 lt upright TD/TS 760 565 250
100 lt upright TD/TS 920 760 250
80 lt horizontal TD/TS 760 395 250
100 lt horizontal TD/TS 920 555 250
dimensions (mm)
33
Technical drawings - graphs - fl ue systems
Gas storage water heaters
33
WALL HUNGSAGN 50SAGN 80SAGN 100
A 306 591 676
B 490 775 860
C 613 898 983
D 265 550 635
FLOOR STANDING
SAG 115 TSAG 150 T
SAG 200 T
A 470 470 570
B 1215 1515 1414
C 1274 1574 1485
D 374 374 337
E 674 824 747
upright 50/80/100 lt
horizontal 80/100 lt
STORAGE THERMOELECTRIC
1 2
dimensions (mm)
dimensions (mm)
1
34
Coaxial fl ue systemGas condensing boilers Luna3 Comfort HT
Nuvola3 Comfort HTPrime HT
KHG714100211
KHG714093510
KHG714100112
KHG714059611
KHG714088910
KHG714059514
KHG714088511
KHG714088610
KHG714099810
KHG714099710
PP HORIZONTAL COAXIAL CHIMNEY 110/160
PP VERTICAL CHIMNEYTERMINAL 80/125
PP VERTICAL CHIMNEYTERMINAL 110/160
PP COAXIAL FLUE TUBES WITHTERMINAL 60/100 L=750 mmsupplied with windproof terminaland sealing collar
PP COAXIAL FLUE TUBES WITH TERMINAL 80/125 L=1000 mm supplied with wind proof terminal and sealing collar
PP COAXIAL FLUE TUBEEXTENSION 60/100L=1000 mm
PP COAXIAL FLUE TUBEEXTENSION 80/125L=1000 mm
PP COAXIAL FLUE TUBEEXTENSION 80/125L=500 mm
PP COAXIAL FLUE TUBEEXTENSION 110/160L=1000 mm
PP COAXIAL FLUE TUBEEXTENSION 110/160L=500 mm
KHG714059715
KHG714088711
KHG714100010
KHG714059815
KHG714088811
KHG714099910
KHG714093910
KHG714093610
KHG714104810
KHG714093710
KHG714104910
PP COAXIAL 87°BEND 60/100
PP COAXIAL 87°BEND 80/125
PP COAXIAL 87°BEND 110/160
PP COAXIAL 45°BEND 60/100
PP COAXIAL 45°BEND 80/125
PP COAXIAL 45°BEND 110/160
PP REDUCTION FROM80/125 TO 60/100
FLAT ROOF TILE TO BEUSED WITH A VERTICALCHIMNEY TERMINAL 80/125
FLAT ROOF TILE TO BEUSED WITH A VERTICALCHIMNEY TERMINAL 110/160
PITCHED ROOF TILE TO BE USED WITH A VERTICALCHIMNEY TERMINAL 110/160;it is adjustable from 15° to 45°
PITCHED ROOF TILE TO BE USED WITH A VERTICALCHIMNEY TERMINAL 80/125;it is adjustable from 15° to 45°
INTERNAL SEALINGCOLLAR Ø 100
KHG714017710
Luna3 System HTLuna HT
35/45/55/65 kWLuna HT
85/100 kW
+KHG 714093910+KHG 714093910
Kit available for every range model. Otherwise specifi ed.
35
Flue tube accessories
Fanned fl ue gas boilers
KHG714101810
KHG714036410
KHG714101710
KHG714103910
KHG714101410
KHG714101510
KHG714087710
KHG714101910
KHG714036710
KHG714036610
KHG714017710
COAXIAL FLUE TUBESWITH TERMINAL 60/100
VERTICAL CHIMNEY TERMINALFOR COAXIAL FLUE SYSTEM
COAXIAL FLUE TUBEEXTENSION 60/100L=1000 MM
COAXIAL FLUE TUBEEXTENSION 60/100L=500 MM
STARTING COAXIAL90° BEND
COAXIAL 90° BEND
COAXIAL CONDENSATECOLLECTOR KIT
ADAPTER FOR 45°BEND/VERTICAL CHIMNEY
FLAT ROOF TILE
PITCHED ROOF TILE
INTERNAL SEALINGCOLLAR Ø 100
Luna3models
Eco3 SlimNuvola3ComfortNuvola3
KHG714101610 COAXIAL 45° BEND
Coaxial fl ue system
KHG714059113
KHG714089010
KHG714105011
KHG714111010
KHG714075610
KHG714093510
KHG714093810
PP DUAL FLUE SYSTEM Ø 80it includes: fl ue reduction,intake connection
PP DUAL FLUE SYSTEM Ø 80it includes: fl ue reduction,intake connection
PP DUAL FLUE SYSTEM Ø 110it includes: fl ue reduction,intake connection
PP reduction fromØ 80 to Ø 60
COAXIAL VERTICALCHIMNEY TERMINAL80/125
DUAL FLUE TUBESADAPTER FORCOAXIAL CHIMNEY
Luna3 Comfort HTNuvola3 Comfort HT
Prime HTLuna3 System HT Luna HT
85/100 kW Power HTLuna HT
35/45/55/65 kW
+KHG 714093810 +KHG 714093810
Gas condensing boilers
Dual fl ue system
Eco3Compact
Main Digit
KHG714102310STARTING COAXIAL45° BEND
KHG714104110 COAXIAL 90° BEND WITH CHECKING PROFILE
KHG714089410COAXIAL FLUE TUBE FORCONNECTION TO LAS SYSTEM
KHG714104010COAXIAL FLUE TUBEEXTENSION 60/100 WITHCHECKING PROFILE
PP vertical fl ue system B23type installation
+KHG 714093810
Kit available for every range model. Otherwise specifi ed.
36
Dual fl ue systemGas condensing boilers
KHW714096910
KHG714059211
KHW714097310
KHG714059311
KHG714075510
KHW714097210
KHG714037411
KHG714106110
KHG714037310
KHG714018510
PP REDUCTION KITFROM Ø 110 TO Ø 100
PP 87° BEND Ø 80
KHG714018411
KHG714093610
KHG714104810
KHG714093710
KHG714010410
KHG714037210
KHG714075410
KHG714051510
KHG714104910
TUBE Ø 80 CENTRINGPack of 5
CLAMPCENTRING KIT
TUBE Ø 60 CENTRING KITPack of 5
TUBE Ø 80 SUPPORTINGBRACKETPack of 5
INTERNAL SEALINGCOLLAR Ø 80
EXTERNAL SEALINGCOLLAR Ø 80
FLAT ROOF TILE Ø 125 TOBE USED WITH A VERTICALCHIMNEY TERMINAL
FLAT ROOF TILE Ø 160 TOBE USED WITH A VERTICALCHIMNEY TERMINAL
PITCHED ROOF TILE Ø 125 to be used with a vertical chimney terminal; it is adjustable from 15° to 45°
PITCHED ROOF TILE Ø 160 to be used with a vertical chimneyterminal; it is adjustable from 15° to 45°
DUAL FLUE TERMINALØ 80
DUAL FLUE TERMINALØ 60
LSD790000450
85-150
45-65
85-150
45-65
85-150
45-65
45-65
45-65
45-65
45-65
45-65
45-65
Luna3 Comfort HTNuvola3 Comfort HT
Prime HTLuna3 System HT Luna HT
85/100 kW Power HTLuna HT
35/45/55/65 kW
KHG714059910
KHG714075310
KHG714075210
KHW714097110
PP TUBE EXTENSION Ø 80L=1000 mm
PP TUBE EXTENSION Ø 80L=500 mm
PP TUBE EXTENSION Ø 60L=1000 mm
PP TUBE EXTENSION Ø 110L=1000 mm
PP TUBE EXTENSION Ø 60L=500 mm
PP TUBE EXTENSION Ø 110L=500 mm
KHW714097010
KHG714059411 45-65
45-65
85-150
85-150
PP 90° BEND Ø 60
PP 87° BEND Ø 110
PP 45° BEND Ø 110
PP 45° BEND Ø 60
PP 45° BEND Ø 80
FLUE TERMINALØ 80
Kit available for every range model. Otherwise specifi ed.
KHG714105710
KHG714105810
KHG714106010
KHG714106210
PP FLEXIBLE TUBEØ 80 L= 1,5 m
PP 90° BEND Ø 80 WITHSUPPORTING BRACKET ANDCONDENSATE DRAININGs
FLEXIBLE CENTRING KITØ 80 (pack of 3)
PP 90° BEND Ø 80 WITHSUPPORTING BRACKET
KHG714111210
KHG714105910
PP FLEXIBLE TUBEØ 80 L= 20 m
Flue tube accessories
37
KHG714061511
KHG714017912
KHG714074810
KHG714111810
KHG714018310
KHG714018210
KHG714038710
DUAL FLUE AFRSYSTEM KIT
KHG714038610
KHG714038510
KHG714105410
KHG714105310
KHG714018010
PAINTED INSULATEDTUBE Ø 80L=500 mm
BEND 90°Ø 80
PAINTED INSULATEDTUBE Ø 80L=1000 mm
ALUMINIUM TUBE Ø 80L=1000 mm
ALUMINIUM TUBE Ø 80L=500 mm
ALUMINIUM TUBE Ø 80L=2000 mm
PAINTED TUBE Ø 80L=500
PAINTED TUBE Ø 80L=1000
DUAL FLUE KIT
Fanned fl ue gas boilers
Dual fl ue system
Luna3Blue
Luna3Silver Space
KHG714105110 INSULATED BEND 90°Ø 80
Luna3models Eco3 Slim
Nuvola3ComfortNuvola3
Eco3Compact
Main Digit
Luna3 Comfort HTNuvola3 Comfort HT
Prime HTLuna3 System HT Luna HT
85/100 kW Power HTLuna HT
35/45/55/65 kW
DUAL FLUE KIT
TRIPLE LIPS GASKETS KITØ 80 (pack of 5)
DUAL FLUE KIT FOR B22 INSTALLATION TYPE Ø 80
Kit available for every range model. Otherwise specifi ed.
Flexible ducting system
Fanned fl ue gas boilers
KHG714018110
KHG714105210
KHG714030510
KHG714054710
KHG714050411
KHG714050311
KHG714017710
KHG714036510
KHG714036710
KHG714036610
KHG714037411
BEND 45°Ø 80
INSULATED BEND 45°Ø 80
INSULATED TUBEADAPTER
AIR INLET/OUTLET FLUESOCKET KIT
AIR OUTLET FLUESOCKET KIT
INTERNAL SEALINGCOLLAR FOR INSULATEDTUBES Ø 100
DUAL FLUE VERTICALCHIMNEY TERMINAL
FLAT ROOF TILE
PITCHED ROOF TILE
TUBE Ø 80CENTRING KITPack of 5
KHG714106110
KHG714037310
KHG714018510
KHG714018411
KHG714010610
KHG714010410
CLAMPCENTRING KIT
TUBE Ø 80 SUPPORTINGBRACKETPack of 5
INTERNAL SEALINGCOLLAR Ø 80
EXTERNAL SEALINGCOLLAR Ø 80
DUAL FLUE HORIZONTALCHIMNEY TERMINAL
DUAL FLUETERMINAL Ø 80
38
Dual fl ue systems
CONDENSATECOLLECTOR KIT
Luna3models Eco3 Slim
Nuvola3ComfortNuvola3
Eco3Compact
Main Digit
Kit available for every range model. Otherwise specifi ed.
39
Flue tube for cascade installationGas condensing boilers
KHG714093211
KHW714097510
KHW714097910
KHG714093311
KHW714097610
KHW714098010
KHG714093411
KHG714111110
KHW714097410
PP FLUE TUBE KIT FORTWO BOILERS Ø 125
PP FLUE TUBE KIT FORTWO BOILERS Ø 200
PP FLUE TUBE KIT Ø 125FOR THE THIRD BOILER
PP FLUE TUBE KIT Ø 160FOR THE THIRD BOILER
PP FLUE TUBE KIT Ø 200FOR THE THIRD BOILER
PP SHUTTER KIT 110/80WITH CONDENSING TRAP
PP SHUTTER KIT 110/110WITH CONDENSING TRAP
KHG714094410
KHW714097810
KHW714098210
KHG714094510
KHG714094610
KHW714097710
KHW714098110
KHW714096910
PP 87° BEND Ø 125
PP 87° BEND Ø 160
PP 87° BEND Ø 200
PP 45° BEND Ø 125Pack of 2
PP TUBE EXTENSIONØ 125L=1000 mm
PP TUBE EXTENSIONØ 160L=1000 mm
PP TUBE EXTENSIONØ 200L=1000 mm
PP REDUCTIONØ 110/100
PP FLUE TUBE KIT FORTWO BOILERS Ø 160
Luna HT85/100 kW
Luna HT35/45/55/65 kW Power HT
Flue tube accessories
45-65
45-65
85-150
45-65
Luna3 System HT
PP SHUTTER KIT 110/110WITH CONDENSING TRAP
Kit available for every range model. Otherwise specifi ed.
40
Hydraulic system accessoriesSlim
Nuvola3ComfortNuvola3
Eco3HT Luna3models
Eco3 CompactMain Digit
KHG714028910HYDRAULIC CONNECTION KITIt includes: 5 telescopic tubes,1 gas inlet valve
KHG714032010
CONNECTION KITIt includes: 4 connections,1 Mains water valve,1 gas inlet valve
UNIVERSALREPLACEMENT KITIt includes: fi ttings and fl exiblestainless steel pipes
KHG714058810Luna3
System HTPrime HT
KHG714083810STOP VALVE KIT NUVOLA3to avoid installation water to get in contact with waterworks
KHG714023211STOP VALVE KITto avoid installation water to get in contact with waterworks
Luna3System HTPrime HT
+KHG714021911/+KHG 714052610
+KHG714021911/+KHG 714052610
+KHG714021911/+KHG 714052610
KHG714023310
VERTICAL TUBECONNECTION KITIt includes 5 tubes for verticalconnection
+KHG714028910+KHG714028910 +KHG714028910
KHG714021911Mains water VALVEWITH FILTER
KHG714052610Mains water VALVEWITHOUT FILTER
2.300Fi,2.230i,2.300i
Nuvola3 Comfort HT/
Prime Storage HT
KHG714024611HEATING SYSTEMFLOW/RETURN VALVEWITH FILTER
KHG714022011HEATING SYSTEMFLOW/RETURN VALVEWITHOUT FILTER
2.300Fi,2.230i,2.300i,
1.300Fi/FiN
Nuvola3 Comfort HT
KHG714112310
Luna3 HT Luna3
System HTPrime HT
HEATING SYSTEM VALVE
KHG714052510 GAS VALVE KIT
KHG714083910
STOP VALVE KIT STORAGE BOILERS to avoid installation water to get in contact with waterworks
Nuvola3 Comfort HT
Prime Storage HT
Kit available for every range model. Otherwise specifi ed.
KHG714110710
KHG714110810
KHG714110910
HYDRAULIC CONNECTION KIT: it includes 5 telescopic tubes, 1 Mains water valve,1 gas inlet valve
HYDRAULIC CONNECTION KIT WITH HEATING TAPS: it includes 5 telescopic tubes, 1 gas inlet valve, 1 mains water valve, 2 heating circuit valves
HYDRAULIC CONNECTION KIT FOR STORAGE BOILERS: it includes 5 telescopic tubes, 1 gas inlet valve, 1 mains water valve
Nuvola3
Blue /Max /Air
41
KHG714086311
KHG714085110
KIT FOR MIXED SYSTEMS(high and low temperature)
ADDITIONAL PUMP TOCONTROL A 3rd ZONE(2nd high temperature zone)
KHG714114210
KSL714114010
KSL714086111
KHG714085410U.B. INOX ADDITIONALEXPANSION VESSEL (4 lt)
COMBI ADDITIONALEXPANSION VESSEL (4 lt)
Completion system accessories
Luna3Comfort HT +
Combi
HT Luna3models
Eco3Nuvola3ComfortNuvola3
SlimEco3
CompactMain Digit
Luna3 System HT
Kit for Comfort HT mixed systems
Luna3Comfort HT/Nuvola3
Comfort HT
Luna3Comfort+ HT Combi
KHG714096310ELECTRIC 3 WAY KIT FOREXTERNAL CONNECTION
KHG714062210PUMP UP 15/60 AOGRUNDFOS
24/25 kW 24 kW
KHG714085210PUMP UPS 15/70 AOGRUNDFOS
31 kW
DHW SENSOR – PUMPCONNECTING CABLEKHW714087410
KHG714084810CONNECTION KIT TOINDIRECT CYLINDER (UB INOX)
Heatingonly
KHW714085610CONNECTION PUMP KITSLIM/U.B. INOX
Slimheating
only
KHG714021611 EXPANSION VESSEL (10 lt)
KHG714034410 ADDITIONAL EXPANSIONVESSEL (2 lt)
KHG714022910 FLOW RESTRICTOR
KFG714079610KIT FOR MIXED SYSTEMS(high and low temperature)
Prime HT
KHG714106610
KHG714022710 RECIRCULATING KIT
Nuvola3Comfort HT
PrimeStorage HT
Hydraulic accessories
KFG714111910
KHG714113810
Nuvola3
3 WAY VALVE MOTOR
Luna3Comfort +
Combi
UB Inox
28 kW
Heatingonly
Eco3Compact
Heatingonly
Heatingonly
Heatingonly
Eco3CompactHeating
only
3 WAY VALVE MOTOR AND HOT WATER TEMPERATURE SENSOR
COMFORT HT KIT FORMIXED SYSTEMS(high and low temperature)
ADDITIONAL PUMP TOCONTROL A 3rd ZONE
KIT FOR HANDLING A LOW TEMPERATURE ZONE
KHG714079710ADDITIONAL EXPANSIONVESSEL (2 lt)
PrimeStorage HT
KHW714096810CONNECTION KIT TOINDIRECT CYLINDER (U.B. INOX)
>35 kW
Kit for mixed systems(high and low temperature)
Kit for mixed systems
(high and low temperature)
Kit available for every range model. Otherwise specifi ed.
42
Hydraulic accessories
Luna HT35/45/55/65 kW
Luna HT85/100 kW Power HT
KHG714104510MANIFOLD PIPES SINGLEBOILER/LAST BOILER
KHG714104610MANIFOLD PIPESBOILERS IN CASCADE
HYDRAULIC CONNECTIONKIT FOR SINGLE BOILERWITH LOW LOSS HEADER
KHG714095612 35 kW
Hydraulic accessories for high effi ciency condensing boilers
KHW714103610MANIFOLD PIPESBOILER IN CASCADE(2 cm between the boilers)
KHW714099010MANIFOLD PIPESBOILERS IN CASCADE(45 cm between the boilers)
MANIFOLD PIPES SINGLEBOILER/LAST BOILER
KHW714104210
KHW714104310BOILER – MANIFOLD PIPEHYDRAULIC CONNECTION
KHW7140986112nd PUMP HYDRAULICCONNECTION
BOILER – MANIFOLD PIPEHYDRAULIC CONNECTIONSINGLE BOILER/BOILERSIN CASCADE
KHG714104410
KHG714095411
HYDRAULIC CONNECTIONSINGLE BOILER/BOILERSIN CASCADE
Luna3 System HT
KHG714117110MANIFOLD PIPES 2 SYSTEM HT BOILERS IN CASCADE
KHG714117210MANIFOLD PIPES 3rd SYSTEM HT BOILER IN CASCADE
Kit available for every range model. Otherwise specifi ed.
43
KHG714062111
KHG714062810
KHG714072511
KHG714106511
PCB INTERFACE FORREMOTE CONTROLLER
REMOTE CONTROLLERAND CLIMATIC REGULATOR (QAA73)
Sensor and thermostats
KHG714072811
Remote controllers
KHG714072612
KHG714106410 REMOTE CONTROLLER ANDCLIMATIC REGULATOR
PCB INTERFACE FORZONE CONTROL
ROOM THERMOSTAT (RT)
OUTDOOR SENSOR (QAC34)
OUTDOOR SENSOR
HT LunaHT 35/45/55/65 kW
LunaHT 85/100 kW
Power HT Luna3models
Eco3Eco3
CompactMain Digit
Nuvola3ComfortNuvola3
Slim
Prime HTPrime
Storage HT
Nuvola3
Luna3System HTPrime HT
(+KHG714072511for Prime HT)
Thermoregulation accessories
KHG714100510
KHG714086910
KHG714086810
KHG714086710
MECHANICAL ROOMTHERMOSTAT
WEEKLY TIMER AND ROOMTHERMOSTAT NICE TIME
WEEKLY TIMER AND ROOMTHERMOSTAT MAGIC TIME
KHG714061610
KHG714061710
MECHANICAL DAILYTIMER KIT
Timers
Prime HT
Prime HTDIGITAL WEEKLY TIMER
PCB FOR REMOTEALARM SIGNAL
Luna3Blue
KHG714114710
REMOTE CONTROLLER ANDCLIMATIC REGULATORWIRELESS (already included in Luna3 Comfort Air)
Kit available for every range model. Otherwise specifi ed.
44
KHG714078310
KHG714079010
KHG714061911
HOT WATER TEMPERATURESENSOR FOR RVA47 (QAZ21)
KHG714078810
Completion system accessories
KHG714078710
KHG714078610
KHG714078910
KHG714076810
Heating fl ow/returnsensor for AGU2.500 (QAD36)
HEATING FLOW/RETURNSENSOR FOR RVA46 ANDRVA47 (QAD21)
MIXING VALVE G3/4’’
MIXING VALVE G1/2’’
MIXING VALVE G1’’
KHG714078511 MOTOR FOR THEMIXING VALVE
Luna3System HT
Luna3System HT
Luna3System HT
Heating only
KHG714113910
KHG714078212
KHG714096610
KHG714107611
KHG714077913
CASCADE CONTROLLER(RVA47) It includes atemperature sensor (QAD21)
Thermoregulation controllers
KHG714078013
KHG714078112
Temperature regulator formixed systems (RVA46) itincludes a temperaturesensor (QAD21)
Boiler interface for climatic regulators RVA46 ANDRVA47 (OCI420)
BOILER CONTROLINTERFACE 0-10 V(AGU 2.511)
Boiler interface for mixed systems with two different temperature (AGU 2.500)
KHG714078410Room sensor: it can beinstalled only withRVA46 (QAA50)
Luna3System HT
Luna3System HT
Luna3 HTNuvola3 HT
Luna3System HT
Luna3System HT
Luna3System HT
Luna3System HT
Luna3System HT
INSTALLATION BOXFOR RVA CONTROLLERS
Heating only
Luna3 Comfort HTNuvola3 HT
HOT WATERTEMPERATURE SENSOR
HOT WATERTEMPERATURE SENSOR
BOILER INTERFACE FOR MIXED SYSTEMS
HT LunaHT 35/45/55/65 kW
LunaHT 85/100 kW
Power HT Luna3models Eco3
Nuvola3ComfortNuvola3
Slim
Kit available for every range model. Otherwise specifi ed.
Thermoregulation accessories
Luna3 Comfort HTNuvola3 HT
Luna3 Comfort HTNuvola3 HT
Luna3 Comfort HTNuvola3 HT
45
Other accessories
Installation templates
KHG714062010
KHG714060111
KSL714086411
KSG714088210
HT
KHG714076411
METAL TEMPLATEUB INOX 80-120
METAL TEMPLATE FORSTORAGE BOILERS
METAL TEMPLATE FORLUNA3 COMFORT / ECO3FANNED FLUE MODELS(for Luna3 Comfort, fanned andopen fl ue models)
Luna3Comfort Eco3
Nuvola3ComfortNuvola3
SlimUB Inox
Luna3System HTPrime HT
Nuvola3Comfort HT/
PrimeStorage HT
Luna3Comfort HT +
Combi
Luna3Comfort +
Combi
KHI714063310
KHI714053511
Electric water heaters
Luna3SilverSpace
KHG714073810
KHG714023011
BOTTOMCOVER
KHG714024310
POLYPHOSPHATEBATCHER
POLYPHOSPHATERECHARGEPack of 4
Other accessories
24 kW
Luna3System HTPrime HT
Luna3System HTPrime HT
KHG714024811
KHG714073410
UPPER COVER FOR OPENFLUE MODELS
UPPER COVERFOR FANNEDFLUE MODELS
Outdoor installation accessories
4 L EXPANSION VESSEL KITfor 50-100 l electric water heaters
UNIVERSAL BRACKET KIT FORHORIZONTAL WATER HEATERS
METAL TEMPLATEBOILERS FOR OUTDOORMODELS
24 kW
Eco3Compact
Main Digit
Kit available for every range model. Otherwise specifi ed.
METAL TEMPLATE
46
Other accessories
Luna Sat
DATATRANSMISSION
CONTROL
KSV714102710
KSV714103010
KSV714102810
KSV714102910
KSV714108610
NETWORK NODE
NETWORK NODE WITH GATEWAY (RS232)
NETWORK NODE WITH GATEWAY FOR TRANSMISSION VIA GSM
REMOTE READER DEVICE
SOFTWARE ACS 26
KSV714102510 FIRST VOLUMETRIC METER FOR R/1, RP/1, R2Z
KSV714102610 FIRST VOLUMETRIC METER FOR RS, RSP, RS2Z
KSV714106311 SECOND VOLUMETRIC METER FOR RP/1
THERMOREGULA-TION
MOUNTING SYSTEM
KHG714072811 QAC34: OUTDOOR SENSOR
KHG714062810 ROOM THERMOSTAT (RT)
KSV714109510 REMOTE CONTROL AND ROOM SENSOR (R2Z, RS, RSP, RS2Z, RA, RA2Z MOD.)
KHG714086710 DIGITAL CHRONOSTAT (R/1, RP/1, MOD.)
KSV714101210 METAL CASE FOR MONOZONE MODELS
KSV714101310 METAL CASE FOR 2 ZONE MODELS
INDIRECTCYLINDER KHG714108410 LUNA SAT B60 FOR RA, RA2Z, MODELS
KSV714118210 SECOND VOLUMETRIC METER FOR RP/1
KSV714110110 SECOND VOLUMETRIC METER FOR R/1, R2Z
KSV714110010 VOLUMETRIC METER FOR RA, RA2Z
KSV714114510 VOLUMETRIC METER FOR RH
KSV714114610 VOLUMETRIC METER FOR RPH
KSV714117010 METAL CASE FOR RH MODEL
47
Other accessories
LNC 710200060
LNC 710200100
LNC 710200080
FLAT ROOF FRAME KIT FOR 2 COLLECTORS
PROBE HOLDER AND HYDRAULIC CAPS
LNC 710200070
FLAT ROOF FRAME KIT FOR 1 COLLECTOR LNC 710200090
INCLINED ROOF FRAME KIT FOR 2 COLLECTORS
INCLINED ROOF FRAME KIT FOR 1 COLLECTOR
Solar collector SB20SR frames
LNC 710200030 HYDRAULIC CONNECTION KIT AMONG COLLECTORS
Collectors for forced draft installation accessories
LNC 710250050
LNC 710250060
INCLINED ROOF FIXING SYSTEM FOR ADDITIONAL SB 25 COLLECTOR *
ROOF LEVEL + 20° FIXING SYSTEM FOR ADDITIONAL SB 25 COLLECTOR
FLAT ROOF FIXING SYSTEM SB 25LNC 710250040
LNC 710250030 ROOF LEVEL + 20° FIXING SYSTEM SB 25
LNC 710250020 INCLINED ROOF FIXING SYSTEM SB 25
Solar collector SB25 frames
LNC 710250070
LNC 710250100
LNC 710250110
FIXING SYSTEM UNDER TILE FOR 2 COLLECTORS
FIXING SYSTEM UNDER TILE FOR 1 ADDITIONAL COLLECTOR*
FLAT ROOF FIXING SYSTEM FOR ADDITIONAL SB 25 COLLECTOR
LNC 710250130 HORIZONTAL SB 25 COLLECTOR FIXING SYSTEM
LNC 710250140 FIXING SYSTEM FOR HORIZONTAL SB 25 ADDITIONAL COLLECTOR *
LNC 710250080 SUPPORT FRAME FOR 1 SB 25 COLLECTOR
LNC 710250090 SUPPORT FRAME FOR 2 SB 25 COLLECTORS
LNC 710250120 SUPPORT FRAME FOR 1 HORIZONTAL SB 25 COLLECTOR
* THE ADDITIONAL COLLECTOR FIXING SYSTEMS HAS TO BE ORDERED TO INSTALL MORE THAN 2 COLLECTORS LINKED IN SEQUENCE. EX: TO INSTALL 4 COLLECTORS, IT MUST BE ORDERED: NR 1 INCLINED ROOF FiXING SYSTEM SB 25, NR 1 SUPPORT FRAME FOR 2 SB 25 COLLECTORS, NR 2 INCLINED ROOF FIXING SYSTEMS FOR ADDITIONAL SB 25 COLLECTOR AND NR 2 SUPPORT FRAMES FOR 1 SB 25 COLLECTOR.
LNC 710260010
LNC 710260050
LNC 710260060
BASIC COVERING FOR 2 SB 25 IN COLLECTORS
VERTICAL COVERING FOR 1 SB 25 IN SIDE EXTENSION
LNC 710260020
BASIC COVERING FOR 1 SB 25 IN COLLECTORLNC 710260120
FIXING SYSTEM FOR 1 SB 25 IN - SB 13 IN ADDITIONAL COLLECTOR
2 SB 25 IN - SB 13 IN COLLECTORS FIXING SYSTEM
SB25 IN - SB13 IN Solar collectors accessories
LNC 710260070
LNC 710260090 COVERING FOR INSTALLING MORE THAN 2 SB 25 IN - SB 13 IN COLLECTORS ON THE SHORT SIDE
COVERING FOR SB 25 IN - SB 13 IN UPPER EXTENSION
LNC 710130010 BASIC COVERING FOR 2 SB 13 IN COLLECTORS
LNC 710260100 BASIC COVERING FOR 2 SB 25 IN COLLECTORS TO BE INSTALLED ON PANTILE ROOVES
LNC 710130020 VERTICAL COVERING FOR SB 13 IN SIDE EXTENSION
LNC 710130030 BASIC COVERING FOR 2 SB 13 IN COLLECTORS TO BE INSTALLED ON PANTILE ROOVES
LSC 710250010
LNC 710000040
LNC 710000050
SOLAR CONTROLLER SENSOR
FLOW REGULATOR INTERFACE
LSC 710000021
COMFORT SOLAR CONTROLLERLSC 710000031
ECO SOLAR CONTROLLER
SOLAR SYSTEM CONNECTION GROUP WITH DIFFERENTIAL CONTROLLER
Other accessories
LSC 710000061
LSC 710000071
LSC 710000010
COMFORT SOLAR SYSTEM CONNECTION GROUP
NON-TOXIC ANTIFROST LIQUID*
NEUTRAL SOLAR SYSTEM CONNECTION GROUP
*MINIMUM QUANTITY THAT MAY BE ORDERED: 5 LT OR 5 LT MULTIPLES
LNC 710260110 VERTICAL COVERING FOR SB 25 IN - SB 13 IN TO BE INSTALLED ON PANTILE ROOVES
48
Wall hung and fl oor standing boilers
49
Wall hung and fl oor standing boilersProducts technical data
Wall hung and fl oor standing boilers
50
Products technical data
51
Quality
Environment
Safetyare Baxi strategic aims and
the awarded certifi cations
ensure compliance with the
specifi c regulations
The Company assumes no responsibility for any possible contents mistakes, and reserves the right to make changes
in products, due to technical or commercial demands, at any time without notice.
Baxi S.p.A. 09-08 (C)
36061 BASSANO DEL GRAPPA (VI) Italy
Via Trozzetti, 20
Tel. +39 0424 517111 - Fax: +39 0424 38089
www.baxiinternational.comwww.baxigroup.com