input: 100 - 240 v ac output : 12v max. 18w type · product specification n1hfsw3 18 12v 1,5a eupii...
TRANSCRIPT
PRODUCT SPECIFICATION N1hFSW3 18 12V 1,5A EuPII Page 1/16
Document prepared and responsible for
M. Mauritz Standard Programme
Approved by Day Month Year Revision
M. Obritzhauser 09 08 17 A
Switch Mode Power Supply Product
Name:
N1hFSW3 18 12V 1,5A EuPII Cable version
Input: 100 - 240 V AC
Output : 12V
max. 18W
Type: N1hFSW3 18 12V 1,5A EuPII
PRODUCT SPECIFICATION N1hFSW3 18 12V 1,5A EuPII Page 2/16
Document prepared and responsible for
M. Mauritz Standard Programme
Approved by Day Month Year Revision
M. Obritzhauser 09 08 17 A
1.1 Evolution ................................................................................................... 3
2 Scope .................................................................................................................. 3
3 Technical Specification Sheet .................................................................................. 4
3.1 Input Specification ...................................................................................... 4
3.2 Safety and Environmental Conditions ............................................................ 4
3.3 Output Specification ................................................................................... 5
3.3.1 Output template ........................................................................... 6
3.4 Mechanical Parameters ............................................................................... 7
3.4.1 Screw proposition and max. moment of torque ................................. 7
3.4.2 Housing dimension ....................................................................... 8
3.4.3 Housing and Potting .................................................................... 10
4 Marking on the housing ....................................................................................... 11
4.1 Laser marking .......................................................................................... 11
4.2 Position of Tc point according IEC 61347 ................................................... 11
5 Reliability ............................................................................................................ 12
5.1 MTBF ...................................................................................................... 12
5.2 Maintainability ......................................................................................... 12
5.3 Temperature cycle test ............................................................................... 12
6 Safety ................................................................................................................. 13
6.1 Dielectric Strength .................................................................................... 13
6.2 Over-current Protection ............................................................................. 13
6.3 Single Component Failure ......................................................................... 13
6.4 Short Circuit ............................................................................................. 13
7 Approvals and test standards ................................................................................ 14
7.1 General................................................................................................... 14
7.2 Test Standards .......................................................................................... 14
7.3 Approvals ................................................................................................ 15
7.4 Description of symbols from marking plate .................................................. 15
8 Packaging and weight .......................................................................................... 16
PRODUCT SPECIFICATION N1hFSW3 18 12V 1,5A EuPII Page 3/16
Document prepared and responsible for
M. Mauritz Standard Programme
Approved by Day Month Year Revision
M. Obritzhauser 09 08 17 A
1.1 Evolution
Edition Date Responsible Reason of change
A 09.08.2017 Mauritz First edition
2 SCOPE
This document describes a switch mode power supply unit (AC/DC converter) with fixed
output voltage.
The unit is designed as flush box module with cables.
The unit is designed as a built in power supply and has to be installed in a non operator
accessible area.
PRODUCT SPECIFICATION N1hFSW3 18 12V 1,5A EuPII Page 4/16
Document prepared and responsible for
M. Mauritz Standard Programme
Approved by Day Month Year Revision
M. Obritzhauser 09 08 17 A
3 TECHNICAL SPECIFICATION SHEET
3.1 Input Specification
Parameter Key Min Typ. Max Unit Test Cond.
Input Voltage UIN 90 264 V AC
Input Current IIN 2 150 500 mA
Input Frequency fIN 47 50 63 Hz
Efficiency
84 % At full load
According EuP Tier II
Switching Frequency fsw 100 kHz
Stand-by power
P stb
300 mW
Without
load
According EuP Tier II
Input Voltage
If the input voltage is out of operating range, the power supply does not meet the full
specification. Above the specified upper limit of the input voltage the unit can get damaged.
Below the specified lower limit of the input voltage the unit does not meet the specification.
Efficiency Under Load
The efficiency is defined as the ratio between the output power and input power.
3.2 Safety and Environmental Conditions
Parameter Key Min Typ. Max Unit Test Cond.
Dielectric Strength 3,9 kVAC
Operating Temperature -20 50 °C
At free
convection
-4 122 °F
Storage Temperature -30 25 80 °C
-22 77 176 °F
Humidity 95 %
Altitude 3000 m Operating
Atmospheric pressure 70 106 kPa
Degree of protection by
enclosure
IP68
Valid only for
housing at cable –
cable version
PRODUCT SPECIFICATION N1hFSW3 18 12V 1,5A EuPII Page 5/16
Document prepared and responsible for
M. Mauritz Standard Programme
Approved by Day Month Year Revision
M. Obritzhauser 09 08 17 A
3.3 Output Specification
Parameter Key Min Typ. Max Unit Test Cond.
Output Voltage U2 11,64 12 12,36 V 0 – 1,5A
Output voltage
tolerance TU2 3 % at PCB
Output Current I2 Nominal 1,5 A
Max. Overload
current I2 Overload
200
130 % of I2 Nominal
UIN = 264V
UIN = 90V
Output Power P2 18 W
Ripple Voltage U2,rms
140
140 mVrms
UIN = 264V
UIN = 90V
The unit is not long time over-current proof. If the unit is powered longer than 1 min in
overload conditions (current range between I2 Nominal and I2 Overload ), the device can be
damaged. The period between two overload conditions has to be at least 15 minutes.
PRODUCT SPECIFICATION N1hFSW3 18 12V 1,5A EuPII Page 6/16
Document prepared and responsible for
M. Mauritz Standard Programme
Approved by Day Month Year Revision
M. Obritzhauser 09 08 17 A
3.3.1 Output template
Specified operating area:
At an output current from 0A to I2 Nominal the unit fulfills all specified data.
Overload area:
At an output current from I2 Nominal to I2 Overload the power supply delivers the specified output
voltage U2.
The unit is not long time overload proof. If the unit is powered longer than 1 min in
overload conditions, the device can be damaged. The period between two overload
conditions has to be at least 15 minutes.
Trickle mode area:
If the power demand would be greater than I2 Overload or the power supply works in short
circuit the output voltage and current can not be defined (this parameters are not stable).
The wattage of the SMPS is de-rated. In this mode the unit can not be damaged. After
removing this conditions the unit fulfills the specification.
0
1
2
3
4
5
6
7
0 0.5 1 1.5 2 I2/A
U2/V
Specified operating area Overload area
Tricle mode area
I2 Nominal I2 Overload
PRODUCT SPECIFICATION N1hFSW3 18 12V 1,5A EuPII Page 7/16
Document prepared and responsible for
M. Mauritz Standard Programme
Approved by Day Month Year Revision
M. Obritzhauser 09 08 17 A
3.4 Mechanical Parameters
3.4.1 Screw proposition and max. moment of torque
Max. moment of torque M= 30Ncm
Screw proposition:
Standard: Slotted pan head screw ISO 1580 max. M3
Alternative: Phillips pan head screw ISO 7045 max. M3
Alternative: fillister socket head screw low design ISO 7984 max. M3
Alternative: fillister socket head screw ISO 4762 max. M3
Standard Operating area Overload
area
PRODUCT SPECIFICATION N1hFSW3 18 12V 1,5A EuPII Page 8/16
Document prepared and responsible for
M. Mauritz Standard Programme
Approved by Day Month Year Revision
M. Obritzhauser 09 08 17 A
3.4.2 Housing dimension
PRODUCT SPECIFICATION N1hFSW3 18 12V 1,5A EuPII Page 9/16
Document prepared and responsible for
M. Mauritz Standard Programme
Approved by Day Month Year Revision
M. Obritzhauser 09 08 17 A
PRODUCT SPECIFICATION N1hFSW3 18 12V 1,5A EuPII
Page
10/16
Document prepared and responsible for
M. Mauritz Standard Programme
Approved by Day Month Year Revision
M. Obritzhauser 09 08 17 A
3.4.3 Housing and Potting
The device is potted.
Housing Material PA
Flammability rate of Housing
V0
Potting Material Polyurethane, UL listed
Colour of Housing black
PRODUCT SPECIFICATION N1hFSW3 18 12V 1,5A EuPII
Page
11/16
Document prepared and responsible for
M. Mauritz Standard Programme
Approved by Day Month Year Revision
M. Obritzhauser 09 08 17 A
4 MARKING ON THE HOUSING
4.1 Laser marking
Product name
Input parameters
Output parameters
Safety instructions
Date code of production
CE marking
Approval marks
4.2 Position of Tc point according IEC 61347
Tc: 85°C max.
PRODUCT SPECIFICATION N1hFSW3 18 12V 1,5A EuPII
Page
12/16
Document prepared and responsible for
M. Mauritz Standard Programme
Approved by Day Month Year Revision
M. Obritzhauser 09 08 17 A
5 RELIABILITY
5.1 MTBF
For the calculation the following standards was used:
MIL-HDBK-217 F
MTBF at 25° ambient temperature:
563.150h
5.2 Maintainability
The power supply is not to be repaired.
5.3 Temperature cycle test
During quality approval the unit passed the EGSTON standard temperature cycle test.
PRODUCT SPECIFICATION N1hFSW3 18 12V 1,5A EuPII
Page
13/16
Document prepared and responsible for
M. Mauritz Standard Programme
Approved by Day Month Year Revision
M. Obritzhauser 09 08 17 A
6 SAFETY
The units pass the following tests:
6.1 Dielectric Strength
The input insulation test voltage is 3,9kV AC 50 Hz, sinusoidal waveform.
6.2 Over-current Protection
The unit is not long time over-current proof. If the unit is powered longer than 1 min in
overload conditions, the device can be damaged. The period between two overload
conditions has to be at least 15 minutes.
6.3 Single Component Failure
A single component failure does not cause any damage to persons or ambient (fire,
explosions, etc).
6.4 Short Circuit
The power supply is designed with a short circuit protection. A shortened output does not
cause any damage to persons or ambient (fire, explosions, etc.) After removing this
conditions the unit fulfills the specification.
PRODUCT SPECIFICATION N1hFSW3 18 12V 1,5A EuPII
Page
14/16
Document prepared and responsible for
M. Mauritz Standard Programme
Approved by Day Month Year Revision
M. Obritzhauser 09 08 17 A
7 APPROVALS AND TEST STANDARDS
7.1 General
The transformer is designed as a safety transformer according EN 61558-2-16 and fulfills
SELF requirements according EN60950-1, EN60335-1, EN61558-2-16
The device is galvanically isolated.
The isolation class is B.
7.2 Test Standards
EN 55014-1 EN 55014-2 EN 55022 EN 55024 EN 60335-1 EN 61558-2-16 EN 60950-1 UL 60950-1 EN 61347-1EN 61347-2-13 EN 61000-3-3 EN 61000-3-2
PRODUCT SPECIFICATION N1hFSW3 18 12V 1,5A EuPII
Page
15/16
Document prepared and responsible for
M. Mauritz Standard Programme
Approved by Day Month Year Revision
M. Obritzhauser 09 08 17 A
7.3 Approvals
C/US NRTL approval issued by Curtis Straus (for Standard product only)
ENEC
Conformity with the EU low voltage directive, EMC directive, ErP directive and
ROHS directive
7.4 Description of symbols from marking plate
Conformity with the relevant EU directives
The power supply has to be disposed appropriately according the local regulations
for Waste Electrical and Electronic Equipment.
For indoor use unly
Read instruction manual
PRODUCT SPECIFICATION N1hFSW3 18 12V 1,5A EuPII
Page
16/16
Document prepared and responsible for
M. Mauritz Standard Programme
Approved by Day Month Year Revision
M. Obritzhauser 09 08 17 A
8 PACKAGING AND WEIGHT
pcs kg size
Single Carton 1 0,12 95x85x30
Power Supply per Packaging Case 50 6 427x196x165
Power Supply per Layer (EU- Pallet)
10 Packaging cases500 81 1200x800x165
1 Full Pallet (9 Layer) 4500 561 1200x800x1500
N1hFxW3 cable version