Version 2.0 – 21/03/2018 INSTALLING LIMIT/HOMING AND EMERGENCY STOP ADD-ON KIT FOR 200MM COIL WINDER Kit Contents The Kit should contain the parts above.

Upload: others

Post on 24-May-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: INSTALLING LIMIT/HOMING AND EMERGENCY STOP ADD-ON … · 2018-03-21 · INSTALLING LIMIT/HOMING AND EMERGENCY STOP ADD-ON KIT FOR 200MM COIL WINDER Kit Contents ... Fix the zig zag

Version 2.0 – 21/03/2018

INSTALLING LIMIT/HOMING AND EMERGENCY

STOP ADD-ON KIT FOR 200MM COIL WINDER

Kit Contents

The Kit should contain the parts above.

Page 2: INSTALLING LIMIT/HOMING AND EMERGENCY STOP ADD-ON … · 2018-03-21 · INSTALLING LIMIT/HOMING AND EMERGENCY STOP ADD-ON KIT FOR 200MM COIL WINDER Kit Contents ... Fix the zig zag

Version 2.0 – 21/03/2018

Installation

Locate the 2 M4 Threads underneath the machine.

Fix the emergency stop plate onto the base plate with the 2 x M4

extended nuts.

Page 3: INSTALLING LIMIT/HOMING AND EMERGENCY STOP ADD-ON … · 2018-03-21 · INSTALLING LIMIT/HOMING AND EMERGENCY STOP ADD-ON KIT FOR 200MM COIL WINDER Kit Contents ... Fix the zig zag

Version 2.0 – 21/03/2018

Remove the nuts and washers from both limit switches.

Thread the long limit switch through the feeder motor hole in the base

plate.

Page 4: INSTALLING LIMIT/HOMING AND EMERGENCY STOP ADD-ON … · 2018-03-21 · INSTALLING LIMIT/HOMING AND EMERGENCY STOP ADD-ON KIT FOR 200MM COIL WINDER Kit Contents ... Fix the zig zag

Version 2.0 – 21/03/2018

Now cable tie the limit switch wire along existing motor cables and snip

the ends off when tight.

Remove this M5 x 12mm bolt from the feeder assembly.

Page 5: INSTALLING LIMIT/HOMING AND EMERGENCY STOP ADD-ON … · 2018-03-21 · INSTALLING LIMIT/HOMING AND EMERGENCY STOP ADD-ON KIT FOR 200MM COIL WINDER Kit Contents ... Fix the zig zag

Version 2.0 – 21/03/2018

Fix the zig zag bracket here with the M5 x 25mm bolt supplied.

Attach the limit switch as shown and adjust to your needs.

Page 6: INSTALLING LIMIT/HOMING AND EMERGENCY STOP ADD-ON … · 2018-03-21 · INSTALLING LIMIT/HOMING AND EMERGENCY STOP ADD-ON KIT FOR 200MM COIL WINDER Kit Contents ... Fix the zig zag

Version 2.0 – 21/03/2018

Remove this M5 x 12mm bolt from the feeder assembly.

Fix the straight bracket here with the M5 x 20mm bolt supplied.

Page 7: INSTALLING LIMIT/HOMING AND EMERGENCY STOP ADD-ON … · 2018-03-21 · INSTALLING LIMIT/HOMING AND EMERGENCY STOP ADD-ON KIT FOR 200MM COIL WINDER Kit Contents ... Fix the zig zag

Version 2.0 – 21/03/2018

Attach the limit switch as shown and adjust to your needs.

Connect the 5 pin DIN plug into the controller box as shown.

Page 8: INSTALLING LIMIT/HOMING AND EMERGENCY STOP ADD-ON … · 2018-03-21 · INSTALLING LIMIT/HOMING AND EMERGENCY STOP ADD-ON KIT FOR 200MM COIL WINDER Kit Contents ... Fix the zig zag

Version 2.0 – 21/03/2018

Your limit/homing and emergency stop add-on kit is now installed and

ready for use.

In the Coil Winder software ensure the limit switches installed and

emergency stop installed boxes are checked, then click save.