instructions . . 11/30/15 mss - armstrong world industries...armstrong ceiling systems * armstrong...
TRANSCRIPT
3.5. T-BAR CONNECTOR CLIPS
AXTBC
3.4. AXBPS SPLINE
SPLINE
DIAGONAL BRACEAS NEEDED
SCREW FLANGETO STUD
GASKET
3.9. AXBPS PERIMETER POCKET(FREE FLOATING FROM WALL)
STUD TO STRUCTUREAS REQUIRED
3.7. METAL PANEL HOLD DOWN CLIPS
AXSPTHDC
INSERT CLIP INTO TOP BOSS OF AXIOM POCKET PERIMETER.PRESS LOWER BODY OF CLIP TOWARDS POCKET UNTILIT SEATS AGAINST POCKET
3 - SIDED POCKET - AXP355
SCREW FLANGETO WALLOR BLOCKINGBLOCKING
HANGER WIRE(OR STUD)
GASKET
3.11. AXBPS PERIMETER POCKET(ATTACHED TO WALL)
3.3. AXBPS FOAM GASKET
AXPFG - GASKET
3.20. PERIMETER CLOSURE CLIP
INSERTCLOSURE
CLIP
14"
38"
4.0. ATTACHING SUSPENSION TO AXBPS
AXTBC
AXTBCMODIFIED CLIP GRID 3/8" OFFSET
4.3. USE STANDARD AX-V-TBC
14"
4.2. AXIOM CONNECTOR CLIP OPTIONS
AXTBCMODIFIED CLIPGRID 14" OFFSET
AXTBCCUT OFF TAB
AXTBC STANDARD CLIP, GRID FLUSH
4.1. AXIOM CONNECTOR CLIP OPTIONS
3" CLOSURE CLIP
WALL CLIP FOR CLOSURE CLIP
3.19.B. AXIOM WALL CLIP WITH HOOK
TILT DIFFUSER PLATE TOENGAGE TOP HOOK
INSERT SPLINETO ALIGN AND
LOCK DIFFUSERPLATE
LOWER DIFFUSER PLATE TO HORIZONTALAND LOCK UNDER POCKET FLANGE
3.18. AXBPS FACE PLATES
AXP355CAXP355C
AXPDFP7
AXPDFP7
18"
4.4. MODIFY THE AXTBC
AXTBCMODIFIED CLIP GRID 1
2" OFFSET
AX-V-TBCCUT OFF TAB
3.16. AXIOM BUILDING PERIMETER EXTENSIONS
INSERT SPLINE TO ALIGNAND LOCK EXTENSIONPLATE
LOWER EXTENSIONPLATE TOVERTICAL
TILT EXTENSION PLATETO ENGAGE TOP HOOK
THREE SIDEDPERIMETERPOCKET -AXP355C
THREE SIDEDPERIMETERPOCKET -AXP355C
PERIMETEREXTENSION- AXPEP4
PERIMETEREXTENSION- AXPEP4
AXIOM DRYWALLBOTTOM TRIM - AXBTSTR
5/8" GYPSUM BOARD
AXP3553-SIDED POCKET
AXTBC
1.1.A. AXIOM BUILDING PERIMETER POCKET
AXTBC
MAIN BEAM
3 SIDEDPERIMETRPOCKET -AXP355
GASKET -AXPFG
AXTBC
MAIN BEAM
3 - SIDEDPERIMETER POCKET- AXP355
CLOSURE CLIP- AXPCC2
AXTBCMAIN BEAM
3 - SIDEDPERIMETERPOCKET- AXP355
MAIN BEAM
AXTBC
AXBTSTR
CLOSUREPLATE
- AXPCC2
3 - SIDEDPERIMETERPOCKET-AXP355
DIFFUSER FACE PLATE(ITEM AXPDFP7)
WALL CLIP WITH HOOK(ITEM AXPWC)
WALL
AXPWC
3.19.A. AXIOM WALL CLIP WITH HOOK
3.1.A. SPLICE PLATESAX4SPLICEB
3.1.B. SPLICE PLATE INSTALLATION (ISO)
TYPICAL PROCEDURE:1. INSERT SPLICES INTO CHANNEL TRIM BOSSES2. CLOSE THE JOINT3. TIGHTEN THE SCREWS
3.19.C. INSTALLING HVAC BOOTS
STUD SUPPORT
3 SIDED POCKETWITH CONNECTION
TO DIFFUSERADDITIONALSUPPORTAS NEEDED
HVAC BOOT
7" DIFFUSER PLATE
GASKETAXPFG
MAIN BEAMBERCAXT
3 SIDED PERIMETERPOCKET - AXP355S
#8 X 916" SCREW
212" STUD AND
KICKER 48" ONCENTER
212" STUD AND
KICKER 48" ONCENTER
MAIN BEAMBERCAXT
#8 X 916" SCREW
3 SIDED PERIMETERPOCKET - AXP355S
GASKETAXPFG
3" CLOSURE CLIPAXPCC3
Armstrong is not licensed to provide professional architecture or engineering design services.
These drawings show typical conditions in which the Armstrong product depicted is installed.
DATE:
DRAWN BY:
DWG. NO.
PROJECT NAME:
SCALE:
CHK BY:
DESC.:
REV:
DATE:
ARMSTRONG CEILING SYSTEMS * ARMSTRONG WORLD INDUSTRIES, INC. * Lancaster, PA * Phone: 877-ARMSTRONG
AXIOM BUILDING PERIMETER SYSTEM
LITERATURE DETAILS
SHEET 3 - INSTRUCTIONS
11/30/15
MSS
. .
.
.
.
They are not a substitute for an architect's or engineer's plan and do not reflect the unique requirements of
local building codes,laws,statutes,ordinances,rules and regulations (Legal Reqquirements) that may be
applicable for a particular installation.
Armstrong does not warrant, and assumes no liability for the accuracy or completeness of
the drawings for a particular installation or their fitness for a particular purpose.
The user is advised to consult with a duly licensed architect or engineer in the particular locale of the
installation to assure compliance with all Legal Requirements.
2 SIDED PERIMETER POCKETAXP255
MAIN BEAM
AXTBC-CLIP
MAIN BEAM
AXTBC
2" CLOSURE CLIPAXPCC2
2 SIDED PERIMETERPOCKET AXP255
MAIN BEAMAXTBC
AXBTSTR
2 SIDED PERIMETERPOCKET AXP255
AXIOM DRYWALL BOTTOM TRIMAXBTSTR 5/8" GYP BOARD
MAIN BEAM
2 SIDED PERIMETERPOCKET AXP255
AXTBC
2" CLOSURE CLIPAXPCC2
ACCLTAXP355S
ARMSTRONG GRID
CEILING TILEAXPCC3 - CLOSURE CLIP
AXP2362-SIDED POCKET
3"
6"
212" FRAMING
3-SIDED POCKETAXP3552
AXTBCAXTBC
8" Max 8" Max4"
AXTBC
ACOUSTICALCEILING PANEL
AXTBC
ACOUSTICALCEILING PANEL
AXFFP4
AXTBC AXTBC
AXIOM 3-SIDED PERIMETER POCKETAXP3552
HANGER WIRESTO STRUCTURE
SUNSCREEN SHADE
BLACKOUT SHADE
3" CLOSURE CLIPAXPCC3
AXTBC
58" GYPSUM BOARD
POCKETLESS DRYWALL REVEALAXPNP38D
SUNSCREEN SHADE
BLACKOUT SHADE
3" CLOSURE CLIPAXPCC3
AXTBC
POCKETLESS SEISMICAXPNP125A
SUNSCREEN SHADE
BLACKOUT SHADE
3" CLOSURE CLIPAXPCC3
AXTBC
58" GYPSUM BOARD
POCKETLESS DRYWALLAXPNPD
SUNSCREEN SHADE
3" CLOSURE CLIPAXPCC3
AXTBC
58" GYPSUM BOARD
POCKETLESSDRYWALL REVEAL
AXPNP38D
SUNSCREEN SHADE
BLACKOUT SHADE
3" CLOSURE CLIPAXPCC3
AXTBC
POCKETLESS ACOUSTICALAXPNP34A
SUNSCREENSHADE
BLACKOUT SHADE
3" CLOSURE CLIPAXPCC3
AXTBC
POCKETLESSAXPNPFPA
DIFFUSER FACE PLATEAXPDFP4 or AXPDFP7
6 516"
SUNSCREENSHADE
BLACKOUTSHADE
3" CLOSURE CLIPAXPCC3
AXTBC
OPTIONAL VENTING AVAILABLEFOR AIR RETURN SLOT
NOTE: SIZE CAN VARY DEPENDING ONPROJECT / SHADE REQUIREMENT
POCKETLESSAXPNPFPA
DIFFUSER FACE PLATEAXPDF4 OR AXPDF7
SUNSCREENSHADE
BLACKOUT SHADE
3" CLOSURE CLIPAXPCC3
AXTBC
OPTIONAL VENTING AVAILABLEFOR AIR RETURN SLOT
NOTE: SIZE CAN VARY DEPENDING ONPROJECT / SHADE REQUIREMENT
POCKETLESS ACOUSTICALAXPNP34A
SCREW TO
PERIMETER
FRAMING
PLYWOOD BLOCKINGAS REQUIRED
3-1/2" STUD TOSTRUCTURE
AXTBC
AXPCC3
OPTIONAL VENTING
CUSTOM SHADE POCKETSIZE VARIES
SUNSCREENSHADE
BLACKOUTSHADE
3" CLOSURE CLIPAXPCC3
AXTBC
58" GYPSUM BOARD
OPTIONAL VENTING AVAILABLEFOR AIR RETURN SLOT
NOTE: SIZE CAN VARY DEPENDING ONPROJECT / SHADE REQUIREMENT
POCKETLESS DRYWALLREVEAL - AXPNPD38
AXTBC
AXPCC3
CUSTOMSHADE POCKET
358" STUD AND TRACK
SUNSCREENSHADE
BLACKOUT SHADE
3" CLOSURE CLIPAXPCC3
AXTBC
OPTIONAL VENTING AVAILABLEFOR AIR RETURN SLOT
NOTE: SIZE CAN VARY DEPENDING ONPROJECT / SHADE REQUIREMENT
POCKETLESS ACOUSTICALAXPNP34ANR
SUNSCREENSHADE
BLACKOUT SHADE
3" CLOSURE CLIPAXPCC3
AXTBC
OPTIONAL VENTING AVAILABLEFOR AIR RETURN SLOT
NOTE: SIZE CAN VARY DEPENDING ONPROJECT / SHADE REQUIREMENT
POCKETLESS SEISMICAXPNPA125
SUNSCREENSHADE
BLACKOUTSHADE
3" CLOSURE CLIPAXPCC3
AXTBC
58" GYPSUM BOARD
OPTIONAL VENTING AVAILABLEFOR AIR RETURN SLOT
NOTE: SIZE CAN VARY DEPENDING ONPROJECT / SHADE REQUIREMENT
POCKETLESS DRYWALLAXPNPD
AXP355C3-SIDED POCKET
AXPEP4H
AXDFP7SLA
AXTBC
Armstrong is not licensed to provide professional architecture or engineering design services.
These drawings show typical conditions in which the Armstrong product depicted is installed.
DATE:
DRAWN BY:
DWG. NO.
PROJECT NAME:
SCALE:
CHK BY:
DESC.:
REV:
DATE:
ARMSTRONG CEILING SYSTEMS * ARMSTRONG WORLD INDUSTRIES, INC. * Lancaster, PA * Phone: 877-ARMSTRONG
They are not a substitute for an architect's or engineer's plan and do not reflect the unique requirements of
local building codes,laws,statutes,ordinances,rules and regulations (Legal Reqquirements) that may be
applicable for a particular installation.
Armstrong does not warrant, and assumes no liability for the accuracy or completeness of
the drawings for a particular installation or their fitness for a particular purpose.
The user is advised to consult with a duly licensed architect or engineer in the particular locale of the
installation to assure compliance with all Legal Requirements.
AXIOM BUILDING PERIMETER SYSTEM
LITERATURE DETAILS
SHEET 4 - INSTALLATIONS
11/30/15
MSS
. .
.
.
.
AXSPLINEFACEPLATE -AXPDFP7
AXDWT(OPTIONAL)
MAIN BEAM
AXTBC
3 - SIDEDPERIMETERPOCKET- AXP355C
FACEPLATEAXPDFP7DT
AXSPLINE
MAIN BEAM
AXTBC
2 SIDEDPERIMETERPOCKETAXP255C
AXDWT(OPTIONAL)
TWO SIDEDPERIMETERPOCKETAXP255C
AXSPLINE
4" AXIOM FACEPLATEAXPDFP4DT
AXTBC
MAIN BEAM
AXDWT(OPTIONAL)
TWO SIDEDPERIMETERPOCKETAXP255C
AXSPLINE
MAIN BEAM
AXTBC
7" FACE PLATEAXPDFP7
AXSPLINE4" FACEPLATE-AXPDFP4
AXTBC
MAINBEAM
3 - SIDEDPERIMETERPOCKET -AXP355C
AXTBC
MAIN BEAMAXIOM PERIMETER7" FACE PLATE -AXPDFP7
3 - SIDED PERIMETERPOCKET- AXP355C
AXSPLINE
AXIOM DIFFUSER4" FACE PLATEAXPDFP4
AXSPLINEAXTBC
MAIN BEAM
TWO SIDED PERIMETERPOCKET AXP255C
3- SIDEDPERIMETERPOCKET- AXP355C
AXSPLINE
4" FACE PLATE- AXPDFP4DT MAIN BEAM
AXTBC
AXDWT (OPTIONAL)
AXTBC
MAIN BEAM
PERIMETEREXTENSIONAXPEP6
TWO SIDEDPERIMETERPOCKETAXP255C
AXSPLINE
AXBTSTR
AXTBCMAIN BEAM
PERIMETEREXTENSIONAXPEP6
TWO SIDEDPERIMETERPOCKETAXP255C
AXSPLINE
MAIN BEAM
AXTBC
PERIMETEREXTENSIONAXPEP8
2 SIDEDPERIMETERPOCKETAXP255C
AXSPLINE
MAINBEAM
AXTBC
PERIMETEREXTENSIONAXPEP8
TWO SIDEDPERIMETERPOCKETAXP255C
AXSPLINE
AXBTSTR
TWO SIDED PERIMETERPOCKET AXP255C
AXSPLINE
BERCAXT
MAIN BEAM
AXIOM 4" FACEPLATE AXPDFP4
212" STUD AND KICKER
48" ON CENTER
#8 X 916" SCREW
#8 X 916" SCREW
TWO PER 10' SECTION
212" STUD TO DECK
AS NEEDED TO SUPPORTVERTICAL LOAD ORAS ENGINEERED BY ADESIGN PROFESSIONAL
AXBTSTR
AXTBC
MAIN BEAM
PERIMETEREXTENSIONPLATEAXPEP4
TWO SIDEDPERIMETERPOCKETAXP255C
AXSPLINE
MAINBEAM
AXTBC
PERIMETEREXTENSIONAXPEP4
TWO SIDEDPERIMETERPOCKETAXP255C
AXSPLINE
AXTBCMAIN BEAM
AXBTSTR
PERIMETEREXTENSION- AXPEP6
3 - SIDEDPERIMETERPOCKET -AXP355C
AXSPLINE
MAIN BEAM
AXTBC
PERIMETEREXTENSION- AXPEP8
3 - SIDEDPERIMETERPOCKET -AXP355C
AXSPLINE
3" CLOSURECLIP
- AXPCC3
MAIN BEAM
AXTBC
PERIMETEREXTENSION- AXPEP8
3 - SIDEDPERIMETERPOCKET -AXP355C
AXSPLINE
MAIN BEAMAXTBC
AXBTSTR
PERIMETEREXTENSION- AXPEP8
3 - SIDEDPERIMETERPOCKET -AXP335C
AXSPLINE
PERIMETEREXTENSION- AXPEP6
AXTBCMAIN BEAM
3 - SIDEDPERIMETERPOCKET- AXP355C
AXSPLINE
AXTBCMAIN BEAM
AXBTSTR
PERIMETEREXTENSION- AXPEP4
3 - SIDEDPERIMETERPOCKET -AXP355C
AXSPLINE
3 SIDED PERIMETERPOCKET- APX355C
AXSPLINE
AXIOM PERIMETEREXTENSION -AXPEP4H
MAIN BEAM
AXIOM PERIMETER EXTENSION- AXPEP4AXTBC
SCREW FLANGE TO WALLOR BLOCKING
GASKETAXPFG
AXP355C3-SIDED PERIMETER
POCKET CONNECTIONTO EXTENSION / DIFFUSER
8" PERIMETEREXTENSION - AXPEPS8
BERCAXTSEISMIC CLIP
AXTBC
STUD
KICKERS EVERY4' O.C.
EXPOSED TEE GRID
WINDOW
T-BARCONNECTOR CLIP
(ITEM AXTBC)
3-SIDED PERIMETERPOCKET CONNECTION
TO EXTENSION / DIFFUSER(ITEM AXP355S)
8" PERIMETEREXTENSION(ITEM AXPEPS8)
KICKERS EVERY4' O.C.
Armstrong is not licensed to provide professional architecture or engineering design services.
These drawings show typical conditions in which the Armstrong product depicted is installed.
DATE:
DRAWN BY:
DWG. NO.
PROJECT NAME:
SCALE:
CHK BY:
DESC.:
REV:
DATE:
ARMSTRONG CEILING SYSTEMS * ARMSTRONG WORLD INDUSTRIES, INC. * Lancaster, PA * Phone: 877-ARMSTRONG
They are not a substitute for an architect's or engineer's plan and do not reflect the unique requirements of
local building codes,laws,statutes,ordinances,rules and regulations (Legal Reqquirements) that may be
applicable for a particular installation.
Armstrong does not warrant, and assumes no liability for the accuracy or completeness of
the drawings for a particular installation or their fitness for a particular purpose.
The user is advised to consult with a duly licensed architect or engineer in the particular locale of the
installation to assure compliance with all Legal Requirements.
AXIOM BUILDING PERIMETER SYSTEM
LITERATURE DETAILS
SHEET 5 - INSTALLATIONS
11/30/15
MSS
. .
.
.
.
WINDOW
EXPOSED TEEMAIN BEAM
ARMSTRONGCOLOR COORDINATEDGRID SYSTEM
EXPOSED TEE2' CROSS TEE
T-BARCONNECTOR CLIP
(ITEM AXTBC)
OPTIONAL STUD
SPLICE PLATE(ITEM AX4SPLICE)
3-SIDED PERIMETER POCKETACOUSTICAL / DRYWALL TRANSITION
(ITEM AXP355)
HANGER WIREINSTALLATION
TO STRUCTURE
WINDOW
EXPOSED TEEMAIN BEAM
ARMSTRONGCOLOR COORDINATEDGRID SYSTEM
EXPOSED TEE2' CROSS TEE
T-BARCONNECTOR CLIP
(ITEM AXTBC)
OPTIONAL STUD
SPLICE PLATE(ITEM AX4SPLICE)
3-SIDED PERIMETERPOCKET CONNECTION
TO EXTENSION / DIFFUSER(ITEM AXP355C)
HANGER WIREINSTALLATION
TO STRUCTURE
8" PERIMETEREXTENSION(ITEM AXPEP8)
WINDOW
2" CLOSURE CLIP(ITEM AXPCC2)
SLOTTED DIFFUSERFACE PLATE
(ITEM AXPDFP7SLA)EXPOSED TEE
MAIN BEAM
ARMSTRONGCOLOR COORDINATEDGRID SYSTEM
EXPOSED TEE2' CROSS TEE
T-BARCONNECTOR CLIP
(ITEM AXTBC)
OPTIONAL STUD
HVAC BOOT
SPLICE PLATE(ITEM AX4SPLICE)
3-SIDED PERIMETERPOCKET CONNECTION
TO EXTENSION / DIFFUSER(ITEM AXP355C)
HANGER WIREINSTALLATION
TO STRUCTURE
WINDOW
ARMSTRONGCOLOR COORDINATEDGRID SYSTEM
EXPOSED TEE2' CROSS TEE
T-BARCONNECTOR CLIP
(ITEM AXTBC)
OPTIONAL STUD
SPLICE PLATE(ITEM AX4SPLICE)
3-SIDED PERIMETER POCKETCONNECTION TO EXTENSION / DIFFUSER
(ITEM AXP355C)
HANGER WIREINSTALLATION
TO STRUCTURE
2" CLOSURE CLIP(ITEM AXPCC2)
CUSTOM DIFFUSERFACE PLATE EXPOSED TEE
MAIN BEAM
WINDOW
EXPOSED TEEMAIN BEAM
ARMSTRONGCOLOR COORDINATEDGRID SYSTEM
EXPOSED TEE2' CROSS TEE
BERC FOR AXIOM(ITEM BERCAXT)
OPTIONAL STUD
SPLICE PLATE(ITEM AX4SPLICE)
3-SIDED PERIMETER POCKETACOUSTICAL / DRYWALL TRANSITION
(ITEM AXP355S)
HANGER WIREINSTALLATION
TO STRUCTURE
INTERIOR WALL
ARMSTRONGAXIOM ANGLE MOLDING(AXM34)
INTERIOR WALL
INTERIORWALL
HANGER WIREINSTALLATION
TO STRUCTURE
CLOSURE CLIP
7" DIFFUSER FACE PLATE(AXPDFPS7)
AXIOM WALL CLIPWITH HOOK
(AXPWC)
Armstrong is not licensed to provide professional architecture or engineering design services.
These drawings show typical conditions in which the Armstrong product depicted is installed.
DATE:
DRAWN BY:
DWG. NO.
PROJECT NAME:
SCALE:
CHK BY:
DESC.:
REV:
DATE:
ARMSTRONG CEILING SYSTEMS * ARMSTRONG WORLD INDUSTRIES, INC. * Lancaster, PA * Phone: 877-ARMSTRONG
They are not a substitute for an architect's or engineer's plan and do not reflect the unique requirements of
local building codes,laws,statutes,ordinances,rules and regulations (Legal Reqquirements) that may be
applicable for a particular installation.
Armstrong does not warrant, and assumes no liability for the accuracy or completeness of
the drawings for a particular installation or their fitness for a particular purpose.
The user is advised to consult with a duly licensed architect or engineer in the particular locale of the
installation to assure compliance with all Legal Requirements.
AXIOM BUILDING PERIMETER SYSTEM
LITERATURE DETAILS
SHEET 6 - ISOs
11/30/15
MSS
. .
.
.
.
AXP236
AXP255
AXP255C
AXP3552
AXP355C
AXP355S
AXP355
NO POCKET DRYWALL TAPING FLANGE3/8" REVEAL WITH CLOSURE CLIP ATTACHMENT
(ITEM AXPNP38D)
NO POCKET DRYWALL TAPING FLANGEWITH CLOSURE CLIP ATTACHMENT
(ITEM AXPNPD)
NO POCKET 3/4" ACOUSTICAL FLANGEWITH CLOSURE CLIP ATTACHMENT
(ITEM AXPNP34A)
NO POCKET 1-1/4" ACOUSTICAL FLANGEWITH CLOSURE CLIP ATTACHMENT
(ITEM AXPNP125A)
AXP25ISC
AXP25OSC
AXP255CISC
AXP355SISC
AXP355CISC
AXP355COSC
AXP355OSC
AXP355ISC
12" NOMINAL
AX4SPLICEBOUTSIDE AND INSIDE
Armstrong is not licensed to provide professional architecture or engineering design services.
These drawings show typical conditions in which the Armstrong product depicted is installed.
DATE:
DRAWN BY:
DWG. NO.
PROJECT NAME:
SCALE:
CHK BY:
DESC.:
REV:
DATE:
ARMSTRONG CEILING SYSTEMS * ARMSTRONG WORLD INDUSTRIES, INC. * Lancaster, PA * Phone: 877-ARMSTRONG
AXIOM BUILDING PERIMETER SYSTEM
LITERATURE DETAILS
SHEET 1 - POCKETS
11/30/15
MSS
. .
.
.
.
They are not a substitute for an architect's or engineer's plan and do not reflect the unique requirements of
local building codes,laws,statutes,ordinances,rules and regulations (Legal Reqquirements) that may be
applicable for a particular installation.
Armstrong does not warrant, and assumes no liability for the accuracy or completeness of
the drawings for a particular installation or their fitness for a particular purpose.
The user is advised to consult with a duly licensed architect or engineer in the particular locale of the
installation to assure compliance with all Legal Requirements.
AXPEPH
(EXTENSION)
AXPEPS6
(EXTENSION)
AXPEP4
(EXTENSION)
AXPEP6
(EXTENSION)
AXPEP8
(EXTENSION)
AXPDFP7
(FACE PLATE)
AXPDFPS7
(FACE PLATE)
AXIOM FIELD FACE PLATE(ITEM AXFFP4)
AXIOM FIELD FACE PLATE(ITEM AXFFP6)
AXPDFP7DT
(FACE PLATE)
AXPDFP4DT
(FACE PLATE)
AXPDFP4
(FACE PLATE)
AXPDFPS7SLB
(FACE PLATE)
AXPDFPS7SLA
(FACE PLATE)
2" AXIOM BUILDING PERIMETER CLOSURE CLIP(ITEM AXPCC2) 3" AXIOM BUILDING PERIMETER CLOSURE CLIP
(ITEM AXPCC3)
AXIOM ADAPTER CLIPWITH 0.75" FLANGE FOR SEISMIC APPLICATIONS
(ITEM AXSA75)
AXIOM BOTTOM DRYWALL TRIMSTRAIGHT FOR 5/8" DRYWALL
(ITEM AXBTSTR)
AXIOM WALL CLIPWITH HOOK FOR FACE PLATE
(ITEM AXPWC)
AXIOM WALL CLIPWITH HOOK FOR CLOSURE CLIP
(ITEM AXPWCCP)
AXIOM BEAM END RETAINING CLIPFOR SEISMIC APPLICATIONS
(ITEM BERCAXT)AXIOM T-BAR CONNECTION CLIP
(ITEM AXTBC)
FOAM GASKETING(ITEM AXPFG)
AXIOM SPLICE PLATE(ITEM AX4SPLICE)
AXIOM BUILDING PERIMETER INTERLOCKING SPLINE(ITEM AXPSPLINE)
2 SIDED PERIMTER TRIM
AXIOM BUILDINGPERIMTER END PLATE
AXIOM BUILDING PERIMETER END PLATE (2 SIDED)PROVIDES A CAPPING AT THE END OF THE PERIMETER POCKET
(ITEM AXCPCIV)
3 SIDED PERIMTER TRIM
AXIOM BUILDINGPERIMTER END PLATE
AXIOM BUILDING PERIMETER END PLATE (3 SIDED)PROVIDES A CAPPING AT THE END OF THE PERIMETER POCKET
(ITEM AXCPCI)
Armstrong is not licensed to provide professional architecture or engineering design services.
These drawings show typical conditions in which the Armstrong product depicted is installed.
DATE:
DRAWN BY:
DWG. NO.
PROJECT NAME:
SCALE:
CHK BY:
DESC.:
REV:
DATE:
ARMSTRONG CEILING SYSTEMS * ARMSTRONG WORLD INDUSTRIES, INC. * Lancaster, PA * Phone: 877-ARMSTRONG
AXIOM BUILDING PERIMETER SYSTEM
LITERATURE DETAILS
SHEET 2 - ACCESSORIES
11/30/15
MSS
. .
.
.
.
They are not a substitute for an architect's or engineer's plan and do not reflect the unique requirements of
local building codes,laws,statutes,ordinances,rules and regulations (Legal Reqquirements) that may be
applicable for a particular installation.
Armstrong does not warrant, and assumes no liability for the accuracy or completeness of
the drawings for a particular installation or their fitness for a particular purpose.
The user is advised to consult with a duly licensed architect or engineer in the particular locale of the
installation to assure compliance with all Legal Requirements.