instrument toolkit training agenda ã training objectives ã toolkit overview ã toolkit...
TRANSCRIPT
Instrument Toolkit Training
Agenda
Training Objectives
Toolkit Overview
Toolkit Installation
Toolkit Import/Export
Examples
Summary
Training Objectives Skills
Customize the Toolkit Environment
Install the Instrument Toolkit
Utilize the Import/Export Features of the Toolkit
Use the Toolkit to Select Valid Model #’s
Perform Technical Calcs for Customers
Generate Reports for Customers
Knowledge Understand the Functionality of All the Toolkit Modules
How to Access Technical Support
Agenda
Training Objectives
Toolkit Overview
Toolkit Installation
Toolkit Import/Export
Examples
Summary
Rosemount Product Sizing & Selection Engineering Database Connectivity Technology Selection
Instrument Toolkit
Orifice Calculations Results 3051CD2A52A1AB4I5 1195S1T1S0010AA Specification Sheet Calculation Report
Process Application Data: Tag Number Process Fluid Parameters Flow Rates Pressure conditions Temperature Conditions Pipe Size/Connection Materials of Construction etc.
Product Sizing & Selection
Example: DP Transmitter w/ Primary Element
Instrument Toolkit Organization Common look and feel across modules.
Instrum ent Toolkit
P re ss u re
S O A P 2 000
P re ss u reA pp lic a tion
D P F low
S O A P 2 000
V o rtex
M a g m e ter
F lo w W iza rd
F lowA pp lic a tion
T em p era tu re
T em p era tu reA pp lic a tion
P re ss u re
S O A P 2 000
A P E X R ad a r
L ev elA pp lic a tion
T oo lbox
Customizing Toolkit
Technical SupportMarketing Contacts
DP Flow
- Joel Lemke
8605
- John Landsom
8611
- Joe Wing
8607
Vortex
- Nicole Ridder
8633
Magmeter
- Greg Gromek
8601
DP Level
- Trent Soberg
8653
Apex
- Tom Wienke
8615
- Jim Willis
8625
Temperature & Pressure
- Brad Mathiowetz
8613
- Todd Wallace
8629
Tech support for ‘module specific’ questionsAll Phones are 906-
Americas MarketingJim Tweedie 949-5161
Product ManagerSteve Rogers 828-3915
Instrument Toolkit Positioning
• Toolkit is primarily used internally to FR.• Inside & Outside sales functions• Order management
• Externally, it is a unique product that can help win more sales.
• As product matures, focus will shift external• Use it to penetrate new accounts, & win big
projects
Training Objectives Skills
Customize the Toolkit Environment
Install the Instrument Toolkit
Utilize the Import/Export Features of the Toolkit
Use the Toolkit to Select Valid Model #’s
Perform Technical Calcs for Customers
Generate Reports for Customers
Knowledge Understand the Functionality of All the Toolkit Modules
How to Access Technical Support
Agenda
Training Objectives
Toolkit Overview
Toolkit Installation
Toolkit Import/Export
Examples
Summary
Instrument Toolkit Installation Typical Installation :
Requires 90 mB of Free Disk Space Includes ALL Help Files Includes PDS Files & Acrobat Viewer Includes Technical Data Sheets
Instrument Toolkit Installation Compact Installation:
Requires 35 mB of Free Disk Space Allows user to access PDS and TDS
information from the CD-Rom Drive Requires User to possess the Installation
CD.
Agenda
Training Objectives
Toolkit Overview
Toolkit Installation
Toolkit Import/Export
Examples
Summary
Customer Need: Specify instruments from Process Data
Flow Rates Pressure Temperature Process
Tag Number Max Normal Min Max Normal Min Max Normal Min FluidFT-101 100 lbs/hr 50 lbs/hr 5 lbs/hr 1000 psi 500 psi 0 psi 200 F 100 F O F Nitrogen
FT-102 100 lbs/hr 50 lbs/hr 5 lbs/hr 1000 psi 500 psi 0 psi 200 F 100 F O F Nitrogen
FT-103 100 lbs/hr 50 lbs/hr 5 lbs/hr 1000 psi 500 psi 0 psi 200 F 100 F O F Nitrogen
FT-104 100 lbs/hr 50 lbs/hr 5 lbs/hr 1000 psi 500 psi 0 psi 200 F 100 F O F Nitrogen
STEP 1: Import process data
STEP 2: Perform sizing calculations
STEP 3: Generate model numbers & spec. sheets
STEP 4: Export data
Instrument Import/Export
Instrument Import/Export
Tagno ServiceNorm Temp
Design Temp
Temp Unit
Nor Press
Design Pres
Press Unit
Max Flow Rate
Norm Flow Rate
Min Flow Rate
Full Flow Rate
Flow Rate Unit
FT-101 UTILITY WATER 70 C 100 200 psia 3 2 0 3 USGPMFT-201 UTILITY STEAM 350 450 F 300 psig 4000 3500 0 lb/hrLT-101 DIESEL FUEL STORAGE70 C 45 200 psia TT-101 BOILER FEED WATER85 F psig WaterPT-101 UTILITY AIR 80 F 150 200 psig AirFT-SPARE UTILITY WATER 70 C 100 200 psig 3 2 0 3 USGPMFT-201 NATURAL GAS 65 100 F 150 250 psig 5000 3500 500 6000 SCFM
Customer’s Process Data
Instrument Import/Export
tag tag t1 tag tag tag f1 tag tagtagno tagmodule_id t31 temp_max temp_nor temp_min f46 temp_unit amb_temp_maxchar integer char double double double double char double
40 4 255 8 8 8 8 18 8Tagno Instrument Type Service Max Temp Norm TempMin Temp Design TempTemp Unit Max Amb Temp
Toolkit Import Header
Instrument Type
• The instrument type must be filled in manually before importing data into the toolkit.
Instrument Type ID Instrument Description
1 Pressure Transmitter
2 Magnetic Flowmeter
3 Differential Pressure Flowmeter
4 Vortex Flowmeter
5 Temperature Sensor, or Transmitter
6 Remote Seals
7 Apex Radar Level Gage
8 Coriolis Flowmeter
Training Objectives Skills
Customize the Toolkit Environment
Install the Instrument Toolkit
Utilize the Import/Export Features of the Toolkit
Use the Toolkit to Select Valid Model #’s
Perform Technical Calcs for Customers
Generate Reports for Customers
Knowledge Understand the Functionality of All the Toolkit Modules
How to Access Technical Support
Agenda
Training Objectives
Toolkit Overview
Toolkit Installation
Toolkit Import/Export
Examples
Summary
DP Transmitter Example
• Transmitter Info (3051C)– Calibrated 0 - 75 in H20– Integral Mount 3-valve coplanar manifold– Meter, FM Explosion-proof Approval– SST Wetted Matl’s
• Find a Model Number and Price• Customer gets 18% disc. on 3051
• Add a spare sensor module part
DP Transmitter Answer
• 3051CD2A02A1AM5E5S5
$1532 (List) less 18% = $1256
• 0305RC32B11 $275
• 03031-1045-0022 $780
DP Flow Example
• Multivariable Transmitter with Std. ASME Orifice
• Line: 6” sch 40• Flows: 2000 / 20,000 / 25,000 lb/hr• Fluid: Steam• Conditions: 150 psig, 400 °F• Size for 100 ”H2O @ Max Flow• SST Wetted Materials, FM Explosion Proof
– Find Models & Prices– E-mail Calc. Sheet as Excel
DP Flow Example
• 3095MA2CABA13AA000AB $2482• 1495PC060A3SAXXXXXBC $149• 1496WN060A3C $380• To E-mail
– Edit CDS & Calc Sheet– save as Excel 5.0
Vortex Example
• Process Data • Water; 0 - 500 USGPM• 120 psig, 65 °F• 6 inch line, 150# Flange (prefer a flanged meter)
• LCD Meter, CSA Explosion Proof• Need a Pulse output (1 pulse /gal)
• Will a 6” Vortex meter work?
• Find a Model & Price
• E-mail the CDS & Calc Sheet as Excel
Vortex Answers
• Yes
• 8800CF060SA1N1P1E6M5 $4013
• To E-mail – Edit CDS & Calc Sheet– save as Excel 5.0
Temperature Example
• Application Data• Smart Temperature Transmitter & RTD• Head Mount Preferred• Process Temp 32 - 120 °F• Ambient Temp in Northern US• U = 6”, 3” Union Extension• Process Connection is 3/4” NPT• Tapered 316 SST Thermowell
• Find models & Price
Temperature Example
• 0078T21C30A060T26129 $233
• 644HNA129 $512
Level Example
• Process Info• Closed vessel, balanced system• 8 ft. between taps, 10 ft. tank height,
transmitter 1 ft. below bottom tap • Min level 0 ft., max level 7.5 ft.• Fill Fluid: D.C. 200, Process S.G. = 0.85• 3” 150# flanges, SST wetted materials• flush ring with 2, ½” NPT connections
• Find the Calibration
• Model & Price for 3051 w/ FFW seals
Level Answers
• Find the Calibration• 4 mA = -89.66 in H20• 20 mA = -13.16 in H20
• 3051CD2A22A1AS2 $1479
• 1199DDB10AFFW71CAA9 $919 ea.($1838 for both)
Training Objectives Skills
Customize the Toolkit Environment
Install the Instrument Toolkit
Utilize the Import/Export Features of the Toolkit
Use the Toolkit to Select Valid Model #’s
Perform Technical Calcs for Customers
Generate Reports for Customers
Knowledge Understand the Functionality of All the Toolkit Modules
How to Access Technical Support
Agenda
Training Objectives
Toolkit Overview
Toolkit Installation
Toolkit Import/Export
Examples
Summary
Summary
The Toolkit design is solid; we have met the original performance targets.
Requirements for the Toolkit satisfy: Engineering Construction firms (E&Cs) End-Users RMT internal users
User acceptance has been positive: Easy to Use Fast
Summary Your support and feedback is integral to the
success of the Toolkit. Users can assist by documenting any Toolkit
issues and sending a cc:mail to Randy Durick, or RMD-Instrument-Toolkit, Eden Prairie.
Enhancements are dependent on feedback gathered from users. All Toolkit related
feedback should be sent via cc:mail to RMD-Instrument Toolkit, Eden Prairie mailbox
Summary
THANK YOU!!