introducing - cloudcmevaliant ™ captivia ™ stent graft . 46-40 mm. 37-28 mm. 25-20 mm. 22 fr. 20...

5
1 Valiant Navion Thoracic Stent Graft System INTRODUCING Source: Data on file at Medtronic. CoveredSeal configuration with tip capture Proximal or distal use Reimagined Design UC201804827a EN ©2019 Medtronic. All rights reserved. Medtronic, Medtronic logo, and Further, Together are trademarks of Medtronic. All other brands are trademarks of a Medtronic company. For distribution in the USA only. 1/19

Upload: others

Post on 01-Jan-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: INTRODUCING - CloudCMEValiant ™ Captivia ™ stent graft . 46-40 mm. 37-28 mm. 25-20 mm. 22 Fr. 20 Fr. 18 Fr. 25 Fr. 24 Fr. 22 Fr. 46-42 mm. 40-34 mm. 32-22 mm. Valiant Captivia

1

Valiant Navion™

Thoracic Stent Graft System

INTRODUCING

Source: Data on file at Medtronic.

CoveredSeal configuration with tip capture Proximal or distal use

Reimagined Design

UC201804827a EN ©2019 Medtronic. All rights reserved. Medtronic, Medtronic logo, and Further, Together are trademarks of Medtronic. All other brands are trademarks of a Medtronic company. For distribution in the USA only. 1/19

Page 2: INTRODUCING - CloudCMEValiant ™ Captivia ™ stent graft . 46-40 mm. 37-28 mm. 25-20 mm. 22 Fr. 20 Fr. 18 Fr. 25 Fr. 24 Fr. 22 Fr. 46-42 mm. 40-34 mm. 32-22 mm. Valiant Captivia

2 UC201804827a EN ©2019 Medtronic. All rights reserved. Medtronic, Medtronic logo, and Further, Together are trademarks of Medtronic. All other brands are trademarks of a Medtronic company. 1/19

REIMAGINED DESIGNEXPANDED OPTIONS ENABLE YOU TO CUSTOMIZE TREATMENT

FreeFlo Allows perfusion into proximal vessels

Tip capture mechanism

≥ 2 cm proximal and distal landing zone

Introducing CoveredSeal When anatomy/pathology dictate

Tip capture mechanism

> 2.5 cm proximal landing zone

Source: Data on file at Medtronic.

Reimagined Design

Page 3: INTRODUCING - CloudCMEValiant ™ Captivia ™ stent graft . 46-40 mm. 37-28 mm. 25-20 mm. 22 Fr. 20 Fr. 18 Fr. 25 Fr. 24 Fr. 22 Fr. 46-42 mm. 40-34 mm. 32-22 mm. Valiant Captivia

3 UC201804827a EN ©2019 Medtronic. All rights reserved. Medtronic, Medtronic logo, and Further, Together are trademarks of Medtronic. All other brands are trademarks of a Medtronic company. 1/19

OPTIMIZED STENT GRAFT DESIGN

Aligned peaks and valleys and shorter struts designed for increased flexibility

Adapts to inner and outer curve of thoracic aorta

Increased distance between stents designed to optimize migration resistance and conformability

Source: Data on file at Medtronic.

Reimagined Design

Page 4: INTRODUCING - CloudCMEValiant ™ Captivia ™ stent graft . 46-40 mm. 37-28 mm. 25-20 mm. 22 Fr. 20 Fr. 18 Fr. 25 Fr. 24 Fr. 22 Fr. 46-42 mm. 40-34 mm. 32-22 mm. Valiant Captivia

Valiant Navion™ stent graft

Valiant™ Captivia™ stent graft

46-40 mm 37-28 mm 25-20 mm

18 Fr22 Fr 20 Fr

22 Fr24 Fr25 Fr

46-42 mm 40-34 mm 32-22 mm Valiant Captivia

Valiant Navion

Reduced taper tip lengths ~1cm

Increased working length by 10 cm

New ergonomic materials

New internal flush port

22Fr

18Fr

20Fr

22Fr

18 Fr delivery system for improved vascular access

37.9% (33/87) females in global trial1

DELIVERY SYSTEM ENHANCEMENTSLOWER PROFILE — UP TO 4 FR REDUCTION

1 30-day data. Data on file at Medtronic.

ReachFurther

UC201804827a EN ©2019 Medtronic. All rights reserved. Medtronic, Medtronic logo, and Further, Together are trademarks of Medtronic. All other brands are trademarks of a Medtronic company. 1/19

4

Page 5: INTRODUCING - CloudCMEValiant ™ Captivia ™ stent graft . 46-40 mm. 37-28 mm. 25-20 mm. 22 Fr. 20 Fr. 18 Fr. 25 Fr. 24 Fr. 22 Fr. 46-42 mm. 40-34 mm. 32-22 mm. Valiant Captivia

Helps prevent graft infolding

Enhances seal

5 UC201804827a EN ©2019 Medtronic. All rights reserved. Medtronic, Medtronic logo, and Further, Together are trademarks of Medtronic. All other brands are trademarks of a Medtronic company. 1/19

FreeFlo Design CoveredSeal Stent Design & W-stent

Tortuosity (centerline length/straight line length) from the proximal end of proximal neck to the distal end of the proximal neck

16.1%severe tortuosity in proximal neck2

(14/87)

1.2% Type Ia Endoleak at 30 Days1

100% Access & Deployment Success1

(1/81)

(87/87)

OPTIMIZED STENT GRAFT DESIGNReimagined Design

1 30-day data. Data on file at Medtronic. Type Ia endoleak (1/81 patients). 2. Core Lab reported.

CoveredSeal

Tip capture mechanism

FreeFlo

Tip capture mechanism

Tapered tip