inverter air conditioning for ... - toshiba-aircon.com.au commercial_march 18... · 2 toshiba air...
TRANSCRIPT
1
INVERTER AIR CONDITIONING FOR LIGHT COMMERCIAL USE
What you’ll find inside:
• Cassette Type
• Ducted Type
• Ceiling Type
• Hi Wall Type
• Controllers
Digital Inverter
Effectiveair filtration
Energy efficient
2
Toshiba Air Conditioning is committed
to delivering the highest standard
of quality and innovation across our
product range and services. For more
than 40 years Toshiba Air Conditioning
has led the world in creating better
air conditioning and setting new
standards in comfort, ease of use,
energy efficiency and climate control.
The Toshiba Air Conditioning product
range encompasses a comprehensive
Inverter range to suit residential
and light commercial applications.
Toshiba Inverter systems provide
excellent energy efficiency, are
reliable and run on R410A non-ozone
depleting refrigerant.
Toshiba Air Conditioning
Toshiba was the first company to
incorporate inverter technology into air
conditioning systems in 1981 and since
then it has maintained a technological
advantage over its competitors.
The development of the exclusive
DC Hybrid Twin-Rotary Inverter
Compressor system has reaffirmed
this ability to innovate and maintain
technological leadership in a very
crowded market. But for Toshiba,
innovation also means a strong
commitment to international
institutions that carefully evaluate
the impact of new technologies
on our environment.
Toshiba combines technological
development with care for future
generations – the result is a range
of energy-efficient air conditioners,
reducing greenhouse gas emissions
at the source.
When technology meets comfort
INVERTER AIR-CONDITIONING • TECHNOLOGY
3
SDI Series 4
Enhanced Energy Efficiency (RAV-SP1104AT-A2, RAV-SP1404AT-A2)
Excellent efficiency, not only below rated EER conditions, but also during partial load, which is the larger part of actual
operating conditions.
In addition to achieving a top ranking during 100% load
(rated) conditions...
For most of the year, the air conditioner (cooler) operates while
the outdoor temperature is less than 30°C.
At this time, the air conditioner load is approximately 50%, and
at this level the EER is significantly greater than during rated
conditions. This indicates energy efficiency in a way that cannot
be expressed using just the rated energy consumption rate.
Equipped with a eco-driving DC twin rotary compressor
A low minimum speed of 10rps has been achieved. This has
further improved the operating efficiency when the load is low
(the minimum in Series 2 was 15rps).
The structure and shape of each compressor component has
been optimised. The area of the rotor magnet has been increased
and a slit introduced to the design. These improvements have
further enhanced efficiency and reduced noise.
10rps Operation Verification Test
To compare operating efficiency under low load operating conditions, field tests were performed where the outdoor
temperature was approximately 24°C. This is about the same as when the air conditioning is set to room temperature.
Measurements were taken that demonstrated that the energy consumption of the new model was 30% less than the current
model (equivalent to the areas enclosed by the energy consumption curves along the time axis).
50010
15
20
25
1,000
1,500
2,000
2,500
* Data compiled in Japan, July 2007
EER
100% LOAD4.52
Partial LOAD5.9
Rotor with slit
Large-area magnet
Office Room
Air Conditioner Temperature
Comparison of Measurement Results (data taken from operating periods with similar outdoor temperatures)
Outdoor Temperature (C)
Power Consum
ption (W)
Power Consumption (Current Model) Power Consumption (New Model)Outdoor Temperature (Current Model) Outdoor Temperature (New Model)
time
50010
15
20
25
1,000
1,500
2,000
2,500
* Data compiled in Japan, July 2007
EER
100% LOAD4.52
Partial LOAD5.9
Rotor with slit
Large-area magnet
Office Room
Air Conditioner Temperature
Comparison of Measurement Results (data taken from operating periods with similar outdoor temperatures)
Outdoor Temperature (C)
Power Consum
ption (W)
Power Consumption (Current Model) Power Consumption (New Model)Outdoor Temperature (Current Model) Outdoor Temperature (New Model)
time
50010
15
20
25
1,000
1,500
2,000
2,500
* Data compiled in Japan, July 2007
EER
100% LOAD4.52
Partial LOAD5.9
Rotor with slit
Large-area magnet
Office Room
Air Conditioner Temperature
Comparison of Measurement Results (data taken from operating periods with similar outdoor temperatures)
Outdoor Temperature (C)
Power Consum
ption (W)
Power Consumption (Current Model) Power Consumption (New Model)Outdoor Temperature (Current Model) Outdoor Temperature (New Model)
time
Rotor with slit
Large-area magnet
Rotor with slit
Large-area magnet
DEMANDRESPONSECAPABLEINVERTER AIR-CONDITIONING • SDI SERIES 4
4
Line up
DI Series Single Phase
RAV-SM564ATP-A1* RAV-SM804AT-A1* RAV-SM1104ATP-A1* RAV-SM1404ATP-A1* RAV-SM1603AT-A1*
4-way Cassette Type RAV-SM564UTP-E RAV-SM804UTP-E RAV-SM1104UTP-E RAV-SM1404UTP-E RAV-SM1604UTP-E
SDI Series Three Phase
RAV-SP1404AT8-A1* RAV-SP1604AT8-A1*
4-way Cassette Type RAV-SM1404UTP-E RAV-SM1604UTP-E
Ducted Type RAV-SM1406BTP-E –
Ceiling Type RAV-SM1408CTP-E RAV-SM1608CTP-E
SDI Series Single Phase
RAV-SP564ATP-A1* RAV-SP804ATP-A1* RAV-SP1104AT-A2* RAV-SP1404AT-A2*
Compact 4-wayCassette Type RAV-SM564MUT-E – – –
4-way Cassette Type RAV-SM564UTP-E RAV-SM804UTP-E RAV-SM1104UTP-E RAV-SM1404UTP-E
Ducted Type RAV-SM566BTP-E RAV-SM806BTP-E RAV-SM1106BTP-E RAV-SM1406BTP-E
Ceiling Type RAV-SM568CTP-E RAV-SM808CTP-E RAV-SM1108CTP-E RAV-SM1408CTP-E
Hi-Wall Type RAV-SM566KRT-A RAV-SM806KRT-A – –
DI Series Single Phase
RAV-SM304ATP-A RAV-SM404ATP-A RAV-SM564ATP-A1 RAV-SM804ATP-A1
Hi-Wall Type RAV-SM307KRTP-A RAV-SM407KRTP-A RAV-SM566KRT-A RAV-SM806KRT-A
Compact Cassette RAV-SM304MUT-E RAV-SM404MUT-E – –
*DRC enabled CDU
INVERTER AIR-CONDITIONING • LINE UP
5
RAV-SM564MUT-E
RAV-SM304MUT-E
RAV-SM404MUT-E
Model
RBC-UM11PG(W)-EPanel
Comfort Operational Installation
InverterAllows step-less regulation of the air-conditioner’s power, which reduces energy consumption and improves comfort.
Auto-turn LouvresAir outlet grilles move automatically to fill every corner of the room with warm or cool air.
Automatic Air Volume ControlDepending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low.
Long-life FilterBuilt-in long-life filter makes maintenance easier.
Hot StartWhen using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room.
Automatic Cooling/HeatingAutomatically switches between cooling and heating mode.
DryGradually dehumidifies the room to create even greater comfort.
Filter SignAutomatic displays on the remote controller say when to perform maintenance for the indoor unit filter.
Limit TimerUses a 168-hour timer with three modes —“ON timer”, “OFF timer” and “Repeat OFF timer”.
Cooling Capacity with an Outdoor Temperature of -15°CStable cooler operation is possible when the outdoor temperature is as low as -15°C.
Built-in Drain PumpThe built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.)
3.5 m
InverterAllows step-less regulation of the air-conditioner’s power, which reduces energy consumption and improves comfort.
Auto-turn LouvresAir outlet grilles move automatically to fill every corner of the room with warm or cool air.
Automatic Air Volume ControlDepending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low.
Long-life FilterBuilt-in long-life filter makes maintenance easier.
Hot StartWhen using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room.
Automatic Cooling/HeatingAutomatically switches between cooling and heating mode.
DryGradually dehumidifies the room to create even greater comfort.
Filter SignAutomatic displays on the remote controller say when to perform maintenance for the indoor unit filter.
Limit TimerUses a 168-hour timer with three modes —“ON timer”, “OFF timer” and “Repeat OFF timer”.
Cooling Capacity with an Outdoor Temperature of -15°CStable cooler operation is possible when the outdoor temperature is as low as -15°C.
Built-in Drain PumpThe built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.)
3.5 m
InverterAllows step-less regulation of the air-conditioner’s power, which reduces energy consumption and improves comfort.
Auto-turn LouvresAir outlet grilles move automatically to fill every corner of the room with warm or cool air.
Automatic Air Volume ControlDepending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low.
Long-life FilterBuilt-in long-life filter makes maintenance easier.
Hot StartWhen using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room.
Automatic Cooling/HeatingAutomatically switches between cooling and heating mode.
DryGradually dehumidifies the room to create even greater comfort.
Filter SignAutomatic displays on the remote controller say when to perform maintenance for the indoor unit filter.
Limit TimerUses a 168-hour timer with three modes —“ON timer”, “OFF timer” and “Repeat OFF timer”.
Cooling Capacity with an Outdoor Temperature of -15°CStable cooler operation is possible when the outdoor temperature is as low as -15°C.
Built-in Drain PumpThe built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.)
3.5 m
Perfect for grid system ceiling
1. This compact unit (575mm x 575mm) fits perfectly into ceilings and matches standard architectural modules, without the need to cut ceiling tiles.
2. The compact & stylish panel design is ideal for fashionable restaurants, shops and offices.
3. The louvers fold tightly against the ceiling when its operation stops.
Designed for simple & easy installation and maintenance
1. The slim design is only 268mm in height allowing it to blend into the surrounding environment neatly.
2. The ceiling type offers easy installation and maintenance, since the electrical box is located inside the unit.
3. Easy installation can also be achieved using the panel adjust pocket.
4. Long drain pump height of 850mm.
5. Available for ceilings up to 3.5m.
6. The drain-check viewing cavity makes it possible to view the drain pan.
InverterAllows step-less regulation of the air-conditioner’s power, which reduces energy consumption and improves comfort.
Auto-turn LouvresAir outlet grilles move automatically to fill every corner of the room with warm or cool air.
Automatic Air Volume ControlDepending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low.
Long-life FilterBuilt-in long-life filter makes maintenance easier.
Hot StartWhen using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room.
Automatic Cooling/HeatingAutomatically switches between cooling and heating mode.
DryGradually dehumidifies the room to create even greater comfort.
Filter SignAutomatic displays on the remote controller say when to perform maintenance for the indoor unit filter.
Limit TimerUses a 168-hour timer with three modes —“ON timer”, “OFF timer” and “Repeat OFF timer”.
Cooling Capacity with an Outdoor Temperature of -15°CStable cooler operation is possible when the outdoor temperature is as low as -15°C.
Built-in Drain PumpThe built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.)
3.5 m
Drain-check viewing cavity
Compact 4-way Cassette Type
DEMANDRESPONSECAPABLEINVERTER AIR-CONDITIONING • CASSETTE
6
MODEL NUMBER - SYSTEM SDI Single Phase DI Single Phase
INDOOR RAV-SM564MUT-E RAV-SM304MUT-E RAV-SM404MUT-E
OUTDOOR RAV-SP564ATP-A1 RAV-SM304ATP-A RAV-SM404ATP-A
REFRIGERANT TYPE R410A R410A R410A
POWER SUPPLY 220-240V/1/50Hz 220-240V/1/50Hz 220-240V/1/50Hz
CO
OLI
NG
Capacity - Rated kW 4.7 2.5 3.6
Capacity - Range (min ~ max) kW 1.2~5.6 0.9~3.0 0.9~4.0
Efficiency (rated) EER 3.38 4.24 4.00
Power Input (min - rated ~ max) kW 0.21~1.39~ 2.29 0.25~0.59~0.82 0.18~0.90~2.00
Operating Current (rated) A 6.45 2.97 4.45
HEA
TIN
G
Capacity - Rated kW 5.6 3.4 4.0
Capacity - Range (min ~ max) kW 0.9~7.4 0.8~4.5 0.8~5.0
Efficiency (rated) COP 3.64 4.47 4.21
Power Input (min - rated ~ max) kW 0.17~1.54~2.37 0.17~0.76~1.40 0.14~0.95~1.70
Operating Current (rated) A 6.45 3.70 4.65
IND
OO
R U
NIT
Dimension (HxWxD) mm 268x575x575 268x575x575 268x575x575
Net Weight kg 16 16 16
Airflow Volume (H/L) L/s 221.7/151.7 177.78/122.22 183.33/130.00
Fan Motor Output W 60 60 60
Sound Pressure(H/L) at 1m distance dBA 43/39/34 40/31(H/L) 40/31(H/L)
Sound Power(H/L) dBA 58/54/49 55/46(H/L) 54/45(H/L)
OU
TDO
OR
UN
IT
Dimension (HxWxD) mm 550x780x290 550x780x290 550x780x290
Net Weight kg 44 33 39
Compressor Type - DC Twin Rotary DC Twin Rotary DC Twin Rotary
Fan Motor Output W 43 43 43
Cooling Operating Noise (Sound Pressure) (H) at 1m distance dBA (@spl) 47 46 49
Cooling Operating Noise (Sound Power) (H) dBA (@swl) 63 61 64
Heating Operating Noise (Sound Pressure) (H) at 1m distance dBA (@spl) 48 47 50
Heating Operating Noise (Sound Power) (H) dBA (@swl) 64 62 65
Cooling Usable Temperature Range OC -15~43 -15~46 -15~46
Heating Usable Temperature Range OC - 20~15 -15~24 -15~24
PIPE
SIZ
E
Liquid Line Ø mm 6.4 6.4 6.4
Gas Line Ø mm 12.7 9.5 12.7
Coupler Style - Flare Flare Flare
Maximum Length m 50 20 20
Chargeless Length m 20 15 15
Maximum Height Difference m 30 10 10
Compact 4-way Cassette Type – Single Phase
INVERTER AIR-CONDITIONING • CASSETTE
7
DEMANDRESPONSECAPABLE
RAV-SM564UTP-ERAV-SM804UTP-ERAV-SM1104UTP-ERAV-SM1404UTP-ERAV-SM1604UTP-E
Models
RBC-U31PGP(W)-EPanel
RBC-AX32U(W)-E
Wireless remotecontroller kit (optional)
InverterAllows step-less regulation of the air-conditioner’s power, which reduces energy consumption and improves comfort.
Auto-turn LouvresAir outlet grilles move automatically to fill every corner of the room with warm or cool air.
Automatic Air Volume ControlDepending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low.
Long-life FilterBuilt-in long-life filter makes maintenance easier.
Hot StartWhen using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room.
Automatic Cooling/HeatingAutomatically switches between cooling and heating mode.
DryGradually dehumidifies the room to create even greater comfort.
Individual louvre controlEnables airflows to be chosen according to user preferences.
Filter SignAutomatic displays on the remote controller say when to perform maintenance for the indoor unit filter.
Limit TimerUses a 168-hour timer with three modes —“ON timer”, “OFF timer” and “Repeat OFF timer”.
Cooling Capacity with an Outdoor Temperature of -15°CStable cooler operation is possible when the outdoor temperature is as low as -15°C.
Built-in Drain PumpThe built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.)
RAV-SM564UTP-E
23 28
2,050mm
4,500mm
6,300mm
Horizontal face750mm
Mode : coolingLouvre position : horizontalFan speed : Hi
Vertical face
(1) Standard swing
Note: Need to set from wired remote controller
Three louvre swing patterns
(2) Diagonally opposite swing
(3) Turn-around swing
(C)
InverterAllows step-less regulation of the air-conditioner’s power, which reduces energy consumption and improves comfort.
Auto-turn LouvresAir outlet grilles move automatically to fill every corner of the room with warm or cool air.
Automatic Air Volume ControlDepending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low.
Long-life FilterBuilt-in long-life filter makes maintenance easier.
Hot StartWhen using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room.
Automatic Cooling/HeatingAutomatically switches between cooling and heating mode.
DryGradually dehumidifies the room to create even greater comfort.
Individual louvre controlEnables airflows to be chosen according to user preferences.
Filter SignAutomatic displays on the remote controller say when to perform maintenance for the indoor unit filter.
Limit TimerUses a 168-hour timer with three modes —“ON timer”, “OFF timer” and “Repeat OFF timer”.
Cooling Capacity with an Outdoor Temperature of -15°CStable cooler operation is possible when the outdoor temperature is as low as -15°C.
Built-in Drain PumpThe built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.)
RAV-SM564UTP-E
23 28
2,050mm
4,500mm
6,300mm
Horizontal face750mm
Mode : coolingLouvre position : horizontalFan speed : Hi
Vertical face
(1) Standard swing
Note: Need to set from wired remote controller
Three louvre swing patterns
(2) Diagonally opposite swing
(3) Turn-around swing
(C)
InverterAllows step-less regulation of the air-conditioner’s power, which reduces energy consumption and improves comfort.
Auto-turn LouvresAir outlet grilles move automatically to fill every corner of the room with warm or cool air.
Automatic Air Volume ControlDepending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low.
Long-life FilterBuilt-in long-life filter makes maintenance easier.
Hot StartWhen using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room.
Automatic Cooling/HeatingAutomatically switches between cooling and heating mode.
DryGradually dehumidifies the room to create even greater comfort.
Individual louvre controlEnables airflows to be chosen according to user preferences.
Filter SignAutomatic displays on the remote controller say when to perform maintenance for the indoor unit filter.
Limit TimerUses a 168-hour timer with three modes —“ON timer”, “OFF timer” and “Repeat OFF timer”.
Cooling Capacity with an Outdoor Temperature of -15°CStable cooler operation is possible when the outdoor temperature is as low as -15°C.
Built-in Drain PumpThe built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.)
RAV-SM564UTP-E
23 28
2,050mm
4,500mm
6,300mm
Horizontal face750mm
Mode : coolingLouvre position : horizontalFan speed : Hi
Vertical face
(1) Standard swing
Note: Need to set from wired remote controller
Three louvre swing patterns
(2) Diagonally opposite swing
(3) Turn-around swing
(C)
InverterAllows step-less regulation of the air-conditioner’s power, which reduces energy consumption and improves comfort.
Auto-turn LouvresAir outlet grilles move automatically to fill every corner of the room with warm or cool air.
Automatic Air Volume ControlDepending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low.
Long-life FilterBuilt-in long-life filter makes maintenance easier.
Hot StartWhen using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room.
Automatic Cooling/HeatingAutomatically switches between cooling and heating mode.
DryGradually dehumidifies the room to create even greater comfort.
Individual louvre controlEnables airflows to be chosen according to user preferences.
Filter SignAutomatic displays on the remote controller say when to perform maintenance for the indoor unit filter.
Limit TimerUses a 168-hour timer with three modes —“ON timer”, “OFF timer” and “Repeat OFF timer”.
Cooling Capacity with an Outdoor Temperature of -15°CStable cooler operation is possible when the outdoor temperature is as low as -15°C.
Built-in Drain PumpThe built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.)
RAV-SM564UTP-E
23 28
2,050mm
4,500mm
6,300mm
Horizontal face750mm
Mode : coolingLouvre position : horizontalFan speed : Hi
Vertical face
(1) Standard swing
Note: Need to set from wired remote controller
Three louvre swing patterns
(2) Diagonally opposite swing
(3) Turn-around swing
(C)
Comfort Operational Installation
InverterAllows step-less regulation of the air-conditioner’s power, which reduces energy consumption and improves comfort.
Auto-turn LouvresAir outlet grilles move automatically to fill every corner of the room with warm or cool air.
Automatic Air Volume ControlDepending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low.
Long-life FilterBuilt-in long-life filter makes maintenance easier.
Hot StartWhen using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room.
Automatic Cooling/HeatingAutomatically switches between cooling and heating mode.
DryGradually dehumidifies the room to create even greater comfort.
Individual louvre controlEnables airflows to be chosen according to user preferences.
Filter SignAutomatic displays on the remote controller say when to perform maintenance for the indoor unit filter.
Limit TimerUses a 168-hour timer with three modes —“ON timer”, “OFF timer” and “Repeat OFF timer”.
Cooling Capacity with an Outdoor Temperature of -15°CStable cooler operation is possible when the outdoor temperature is as low as -15°C.
Built-in Drain PumpThe built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.)
RAV-SM564UTP-E
23 28
2,050mm
4,500mm
6,300mm
Horizontal face750mm
Mode : coolingLouvre position : horizontalFan speed : Hi
Vertical face
(1) Standard swing
Note: Need to set from wired remote controller
Three louvre swing patterns
(2) Diagonally opposite swing
(3) Turn-around swing
(C)
InverterAllows step-less regulation of the air-conditioner’s power, which reduces energy consumption and improves comfort.
Auto-turn LouvresAir outlet grilles move automatically to fill every corner of the room with warm or cool air.
Automatic Air Volume ControlDepending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low.
Long-life FilterBuilt-in long-life filter makes maintenance easier.
Hot StartWhen using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room.
Automatic Cooling/HeatingAutomatically switches between cooling and heating mode.
DryGradually dehumidifies the room to create even greater comfort.
Individual louvre controlEnables airflows to be chosen according to user preferences.
Filter SignAutomatic displays on the remote controller say when to perform maintenance for the indoor unit filter.
Limit TimerUses a 168-hour timer with three modes —“ON timer”, “OFF timer” and “Repeat OFF timer”.
Cooling Capacity with an Outdoor Temperature of -15°CStable cooler operation is possible when the outdoor temperature is as low as -15°C.
Built-in Drain PumpThe built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.)
RAV-SM564UTP-E
23 28
2,050mm
4,500mm
6,300mm
Horizontal face750mm
Mode : coolingLouvre position : horizontalFan speed : Hi
Vertical face
(1) Standard swing
Note: Need to set from wired remote controller
Three louvre swing patterns
(2) Diagonally opposite swing
(3) Turn-around swing
(C)
InverterAllows step-less regulation of the air-conditioner’s power, which reduces energy consumption and improves comfort.
Auto-turn LouvresAir outlet grilles move automatically to fill every corner of the room with warm or cool air.
Automatic Air Volume ControlDepending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low.
Long-life FilterBuilt-in long-life filter makes maintenance easier.
Hot StartWhen using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room.
Automatic Cooling/HeatingAutomatically switches between cooling and heating mode.
DryGradually dehumidifies the room to create even greater comfort.
Individual louvre controlEnables airflows to be chosen according to user preferences.
Filter SignAutomatic displays on the remote controller say when to perform maintenance for the indoor unit filter.
Limit TimerUses a 168-hour timer with three modes —“ON timer”, “OFF timer” and “Repeat OFF timer”.
Cooling Capacity with an Outdoor Temperature of -15°CStable cooler operation is possible when the outdoor temperature is as low as -15°C.
Built-in Drain PumpThe built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.)
RAV-SM564UTP-E
23 28
2,050mm
4,500mm
6,300mm
Horizontal face750mm
Mode : coolingLouvre position : horizontalFan speed : Hi
Vertical face
(1) Standard swing
Note: Need to set from wired remote controller
Three louvre swing patterns
(2) Diagonally opposite swing
(3) Turn-around swing
(C)
Temperature conditioning
Individual Louvre Control
• The angles of each of the four louvres can be set individually
• Enables airflow to be chosen according to user preferences.
Easy installation
The panel is attached using the bolt that is already installed on the indoor unit.
4-way Cassette Type
INVERTER AIR-CONDITIONING • CASSETTE
8
INDOOR RAV-SM564UTP-E RAV-SM804UTP-E RAV-SM1104UTP-E RAV-SM1404UTP-E
OUTDOOR RAV-SP564ATP-A1 RAV-SP804ATP-A1 RAV-SP1104AT-A2 RAV-SP1404AT-A2
REFRIGERANT TYPE R410A R410A R410A R410A
POWER SUPPLY/PH/FREQ Units 220-240V/1/50Hz 220-240V/1/50Hz 220-240V/1/50Hz 220-240V/1/50Hz
CO
OLI
NG
Capacity - Rated kW 5.3 7.1 10 12.5
Capacity - Range (min ~ max) kW 1.2 ~ 5.6 1.9~8.0 2.6~12.0 2.6~14.0
Efficiency (rated) EER 3.61 3.82 4.52 3.96
Power Input (min ~ rated ~ max) kW 0.20~1.47~1.95 0.30~1.86~2.52 0.64~2.21~3.60 0.64~3.16~4.40
Operating Current (rated) A 6.82 8.72 10.36 14.89
HEA
TIN
G
Capacity - Rated kW 5.6 8.0 11.2 14
Capacity - Range (min ~ max) kW 0.9~8.1 1.3~11.3 2.4~13.0 2.4~16.5
Efficiency (rated) COP 4.63 4.19 4.79 4.36
Power Input (min ~ rated ~ max) kW 0.15~1.21~2.4 0.25~1.91~3.52 0.52~2.34~4.20 0.52~3.21~4.50
Operating Current (rated) A 6.82 8.72 10.96 14.89
IND
OO
R U
NIT
Dimension (HxWxD) mm 256x840x840 256x840x840 319x840x840 319x840x840
Net Weight kg 20 20 24 24
Airflow Volume (H/L) L/s 291.7/216.7 341.7/225.0 558.4/325.1 583.5/341.7
Fan Motor Output W 14 20 68 72
Sound Pressure (H/M/L) at 1m distance dBA 32/29/28 35/31/28 43/38/33 44/38/34
Sound Power (H/M/L) dBA 47/44/43 50/46/43 58/53/48 59/53/49
OU
TDO
OR
UN
IT
Dimension (HxWxD) mm 550x780x290 890x900x320 1340x900x320 1340x900x320
Net Weight kg 44 66 93 93
Compressor Type – DC Twin Rotary DC Twin Rotary DC Twin Rotary DC Twin Rotary
Fan Motor Output W 43 63 100+100 100+100
Cooling Operating Noise (Sound Pressure) (H) at 1m distance
dBA (@spl) 47 48 49 51
Cooling Operating Noise (Sound Power) (H) dBA (@swl) 63 64 66 68
Heating Operating Noise (Sound Pressure) (H) at 1m distance
dBA (@spl) 48 49 50 52
Heating Operating Noise (Sound Power) (H) dBA (@swl) 64 65 67 69
Cooling Usable Temperature Range 0C -15~43 -15~43 -15~43 -15~43
Heating Usable Temperature Range 0C -20~15 -20~15 -20~15 -20~15
PIPE
SIZ
E
Liquid Line Ø mm 6.4 9.5 9.5 9.5
Gas Line Ø mm 12.7 15.9 15.9 15.9
Coupler Style – Flare Flare Flare Flare
Drain (Inside Diameter) Ø mm VP25 VP25 VP25 VP25
Maximum Length m 50 50 75 75
Chargeless Length m 20 30 30 30
Maximum Height Difference m 30 30 30 30
4-way Cassette Type Super Digital Inverter – Single Phase
INVERTER AIR-CONDITIONING • CASSETTE
9
DEMANDRESPONSECAPABLE
INDOOR RAV-SM1404UTP-E RAV-SM1604UTP-E
OUTDOOR RAV-SP1404AT8-A1 RAV-SP1604AT8-A1
REFRIGERANT TYPE R410A R410A
POWER SUPPLY/PH/FREQ - (CDU) Units 380-415V/3/50Hz 380-415V/3/50Hz
CO
OLI
NG
Capacity - Rated kW 12.5 14
Capacity - Range (min ~ max) kW 2.6-14.0 2.6-16.0
Efficiency (rated) EER 3.61 3.12
Power Input (min ~ rated ~ max) kW 0.66-3.46-4.40 0.66-4.49-5.70
Operating Current (rated) A 6.03 7.55
HEA
TIN
G
Capacity - Rated kW 14 16.0
Capacity - Range (min ~ max) kW 2.4-18.0 2.4-19.0
Efficiency (rated) COP 4.09 3.72
Power Input (min ~ rated ~ max) kW 0.53-3.42-5.50 0.53-4.30-6.51
Operating Current (rated) A 6.03 7.55
IND
OO
R U
NIT
Dimension (HxWxD) mm 319x840x840 319x840x840
Net Weight kg 24 24
Airflow Volume (H) L/s 583 592
Fan Motor Output W 72 72
Heating Operating Noise (Sound Pressure) (H/L) at 1m distance dBA (@spl) 44/34 45/36
Heating Operating Noise (Sound Power) (H/L) dBA (@swl) 59/49 60/51
OU
TDO
OR
UN
IT
Dimension (HxWxD) mm 1340x900x320 1340x900x320
Net Weight kg 95 95
Compressor Type – DC Twin Rotary DC Twin Rotary
Fan Motor Output W 100+100 100+100
Cooling Operating Noise (Sound Pressure) (H) at 1m distance dBA (@spl) 51 51
Cooling Operating Noise (Sound Power) (H) dBA (@swl) 68 68
Heating Operating Noise (Sound Pressure) (H) at 1m distance dBA (@spl) 52 53
Heating Operating Noise (Sound Power) (H) dBA (@swl) 69 70
Cooling Usable Temperature Range OC -15~46 -15~46
Heating Usable Temperature Range OC -20~15 -20~15
PIPE
SIZ
E
Liquid Line Ø mm 9.5 9.5
Gas Line Ø mm 15.9 15.9
Coupler Style – Flare Flare
Maximum Length m 75 75
Chargeless Length m 30 30
Maximum Height Difference m 30 30
4-way Cassette Type Super Digital Inverter – 3 Phase
INVERTER AIR-CONDITIONING • CASSETTE
10
INDOOR RAV-SM564UTP-E RAV-SM804UTP-E RAV-SM1104UTP-E RAV-SM1404UTP-E RAV-SM1604UTP-E
OUTDOOR RAV-SM564ATP-A1 RAV-SM804ATP-A1 RAV-SM1104ATP-A1 RAV-SM1404ATP-A1 RAV-SM1603AT-A1
REFRIGERANT TYPE R410A R410A R410A R410A R410A
POWER SUPPLY/PH/FREQ Units 220-240V/1/50Hz 220-240V/1/50Hz 220-240V/1/50Hz 220-240V/1/50Hz 220-240V/1/ 50Hz
CO
OLI
NG
Capacity - Rated kW 4.8 6.1 10.0 10.8 13
Capacity - Range (min ~ max) kW 1.5 - 5.6 1.5 - 8.0 3.0 - 11.2 3.0 - 12.5 3.0 - 16.0
Efficiency (rated) EER 3.29 3.26 3.31 3.00 3.12
Power Input (min ~ rated ~ max) kW 0.26-1.46-1.88 0.26-1.87-2.60 0.60-3.02-4.10 0.60-3.60-4.71 0.65~4.49~5.70
Operating Current (rated) A 7.05 - 6.60 8.75 - 8.20 14.60 - 13.50 17.20 - 15.90 21.48
HEA
TIN
G
Capacity - Rated kW 5.3 7.0 11.2 12.2 16
Capacity - Range (min ~ max) kW 1.5 - 6.3 1.5 - 8.5 3.0 - 13.0 3.0 - 15.0 3.0 - 18.0
Efficiency (rated) COP 3.90 3.74 3.82 3.73 3.61
Power Input (min ~ rated ~ max) kW 0.26-1.36-2.08 0.26-1.87-2.70 0.60-2.93-4.30 0.60-3.27-4.50 0.65~4.43~6.51
Operating Current (rated) A 6.56 - 6.15 8.75 - 8.20 14.17-13.10 16.30-15.00 21.20
IND
OO
R U
NIT
Dimension (HxWxD) mm 256x840x840 256x840x840 319x840x840 319x840x840 319x840x840
Net Weight kg 20 20 24 24 24
Airflow Volume (H/L) L/s 292/217 342/225 558/325 583/342 591.8/350.1
Fan Motor Output W 14 20 68 72 72
Heating Operating Noise (Sound Pressure) (H/M/L) at 1m distance dBA (@spl) 32/29/28 35/31/28 43/38/33 44/38/34 45/40/36
Heating Operating Noise (Sound Power) (H/M/L) dBA (@swl) 47/44/43 50/46/43 58/53/48 59/53/49 60/55/51
OU
TDO
OR
UN
IT
Dimension (HxWxD) mm 550x780x290 550x780x290 890x900x320 890x900x320 1340x900x320
Net Weight kg 40 44 68 68 99
Compressor Type – DC Twin Rotary DC Twin Rotary DC Twin Rotary DC Twin Rotary DC Twin Rotary
Fan Motor Output W 43 43 100 100 100+100
Cooling Operating Noise (Sound Pressure) (H) at 1m distance
dBA (@spl) 46 48 53 54 51
Cooling Operating Noise (Sound Power) (H) dBA (@swl) 63 65 70 70 68
Heating Operating Noise (Sound Pressure) (H) at 1m distance
dBA (@spl) 48 52 54 55 53
Heating Operating Noise (Sound Power) (H) dBA (@swl) 65 69 71 71 70
Cooling Usable Temperature Range OC -15~46 -15~46 -15~46 -15~46 -15~43
Heating Usable Temperature Range OC -15~15 -15~15 -15~15 -15~15 -15~15
PIPE
SIZ
E
Liquid Line Ø mm 6.4 9.5 9.5 9.5 9.5
Gas Line Ø mm 12.7 15.9 15.9 15.9 15.9
Coupler Style – Flare Flare Flare Flare Flare
Drain (Inside Diameter) Ø mm VP25 VP25 VP25 VP25 VP25
Maximum Length m 30*1 30*2 50*3 50*3 50*3
Chargeless Length m 20 20 30 30 30
Maximum Height Difference m 30 30 30 30 30
4-way Cassette Type Digital Inverter – Single Phase
*1 21m to 30m need to extra charge 20g/m*2 21m to 30m need to extra charge 40g/m*3 31m to 50m need to extra charge 40g/m
Notes:
INVERTER AIR-CONDITIONING • CASSETTE
11
RAV-SM566BTP-ERAV-SM806BTP-ERAV-SM1106BTP-ERAV-SM1406BTP-E
Models
InverterAllows step-less regulation of the air-conditioner’s power, which reduces energy consumption and improves comfort.
Automatic Air Volume ControlDepending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low.
Long-life FilterBuilt-in long-life filter makes maintenance easier.
Hot StartWhen using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room.
Automatic Cooling/HeatingAutomatically switches between cooling and heating mode.
DryGradually dehumidifies the room to create even greater comfort.
Filter SignAutomatic displays on the remote controller say when to perform maintenance for the indoor unit filter.
Built-in Drain PumpThe built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.)
Limit TimerUses a 168-hour timer with three modes —“ON timer”, “OFF timer” and “Repeat OFF timer”.
Cooling Capacity with an Outdoor Temperature of -15°CStable cooler operation is possible when the outdoor temperature is as low as -15°C.
Wide range of applications
The use of ducts allows air outlets to be conveniently installed anywhere on the ceiling, eliminating the conspicuous presence of the air conditioner in the center of the room. Not only can this be applied to a wide variety of layouts from narrow spaces to polygonal rooms; it also greatly improves the aesthetics of a room with its unobtrusive presence.
High static pressure
External static pressure can be raised as high as 120 Pa, so that all areas of the room can be reached for even temperature distribution, no matter how complex the layout.
High-lift drain pump
The flexible piping layout is made possible by an optionally available drain-pump kit that raises the drain piping up to 27cm from the drain port.
Comfort Operational Installation
InverterAllows step-less regulation of the air-conditioner’s power, which reduces energy consumption and improves comfort.
Automatic Air Volume ControlDepending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low.
Long-life FilterBuilt-in long-life filter makes maintenance easier.
Hot StartWhen using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room.
Automatic Cooling/HeatingAutomatically switches between cooling and heating mode.
DryGradually dehumidifies the room to create even greater comfort.
Filter SignAutomatic displays on the remote controller say when to perform maintenance for the indoor unit filter.
Built-in Drain PumpThe built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.)
Limit TimerUses a 168-hour timer with three modes —“ON timer”, “OFF timer” and “Repeat OFF timer”.
Cooling Capacity with an Outdoor Temperature of -15°CStable cooler operation is possible when the outdoor temperature is as low as -15°C.
InverterAllows step-less regulation of the air-conditioner’s power, which reduces energy consumption and improves comfort.
Automatic Air Volume ControlDepending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low.
Long-life FilterBuilt-in long-life filter makes maintenance easier.
Hot StartWhen using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room.
Automatic Cooling/HeatingAutomatically switches between cooling and heating mode.
DryGradually dehumidifies the room to create even greater comfort.
Filter SignAutomatic displays on the remote controller say when to perform maintenance for the indoor unit filter.
Built-in Drain PumpThe built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.)
Limit TimerUses a 168-hour timer with three modes —“ON timer”, “OFF timer” and “Repeat OFF timer”.
Cooling Capacity with an Outdoor Temperature of -15°CStable cooler operation is possible when the outdoor temperature is as low as -15°C.
InverterAllows step-less regulation of the air-conditioner’s power, which reduces energy consumption and improves comfort.
Automatic Air Volume ControlDepending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low.
Long-life FilterBuilt-in long-life filter makes maintenance easier.
Hot StartWhen using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room.
Automatic Cooling/HeatingAutomatically switches between cooling and heating mode.
DryGradually dehumidifies the room to create even greater comfort.
Filter SignAutomatic displays on the remote controller say when to perform maintenance for the indoor unit filter.
Built-in Drain PumpThe built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.)
Limit TimerUses a 168-hour timer with three modes —“ON timer”, “OFF timer” and “Repeat OFF timer”.
Cooling Capacity with an Outdoor Temperature of -15°CStable cooler operation is possible when the outdoor temperature is as low as -15°C.
Versatile and Clever Duct Type
INVERTER AIR-CONDITIONING • DUCTED
12
INDOOR RAV-SM566BTP-E RAV-SM806BTP-E RAV-SM1106BTP-E RAV-SM1406BTP-E
OUTDOOR RAV-SP564ATP-A1 RAV-SP804ATP-A1 RAV-SP1104AT-A2 RAV-SP1404AT-A2
REFRIGERANT TYPE R410A R410A R410A R410A
POWER SUPPLY/PH/FREQ UNITS 220-240V/1/50Hz 220-240V/1/50Hz 220-240V/1/50Hz 220-240V/1/50Hz
CO
OLI
NG
Capacity - Rated kW 4.9 7.1 10.0 12.5
Capacity - Range (min ~ max) kW 1.2-5.6 1.9-8.0 2.6-12.0 2.6-14.0
Efficiency (rated) EER 3.25 3.45 3.79 3.26
Power Input (min ~ rated ~ max) kW 0.21/1.51/2.05 0.30/2.06/2.88 0.64/2.64/3.80 0.64/3.83/4.47
Operating Current (rated) A 7.00 9.65 12.30 17.70
HEA
TIN
G
Capacity - Rated kW 5.6 8.0 11.2 14.0
Capacity - Range (min ~ max) kW 0.9-7.4 1.3-10.6 2.4-13.0 2.4-16.5
Efficiency (rated) COP 3.61 3.62 4.04 3.81
Power Input (min ~ rated ~ max) kW 0.17/1.55/2.51 0.27/2.21/3.50 0.52/2.77/4.00 0.52/3.67/4.50
Operating Current (rated) A 7.18 10.3 12.90 17.00
IND
OO
R U
NIT
Dimension (HxWxD) mm 275x700x750 275x1000x750 275x1400x750 275x1400x750
Net Weight kg 23 30 40 40
Airflow Volume (H/L) L/s 222/133 333/200 583/350 583/350
Fan Motor Output W 150 150 250 250
Heating Operating Noise (Sound Pressure) (H/M/L) at 1m distance
dBA (@spl) 33/29/25 34/30/26 40/36/33 40/36/33
Heating Operating Noise (Sound Power) (H/M/L)
dBA (@swl) 55/51/46 55/51/46 63/58/54 63/58/54
OU
TDO
OR
UN
IT
Dimension (HxWxD) mm 550x780x290 890x900x320 1340x900x320 1340x900x320
Net Weight kg 44 66 93 93
Compressor Type – DC Twin Rotary DC Twin Rotary DC Twin Rotary DC Twin Rotary
Fan Motor Output W 43 63 100+100 100+100
Cooling Operating Noise (Sound Pressure) (H) at 1m distance
dBA (@spl) 47 48 49 51
Cooling Operating Noise (Sound Power) (H) dBA (@swl) 63 64 66 68
Heating Operating Noise (Sound Pressure) (H) at 1m distance
dBA (@spl) 48 49 50 52
Heating Operating Noise (Sound Power) (H) dBA (@swl) 64 65 67 69
Cooling Usable Temperature Range 0C -15~43 -15~43 -15~43 -15~43
Heating Usable Temperature Range 0C -20~15 -20~15 -20~15 -20~15
PIPE
SIZ
E
Liquid Line Ø mm 6.4 9.5 9.5 9.5
Gas Line Ø mm 12.7 15.9 15.9 15.9
Coupler Style – Flare Flare Flare Flare
Maximum Length m 50 50 75 75
Chargeless Length m 20 30 30 30
Maximum Height Difference m 30 30 30 30
Duct Type – Super Digital Inverter
DEMANDRESPONSECAPABLEINVERTER AIR-CONDITIONING • DUCTED
13
INDOOR RAV-SM1406BTP-E
OUTDOOR RAV-SP1404AT8-A1
REFRIGERANT TYPE R410A
POWER SUPPLY/PH/FREQ - (CDU) Units 380-415V/3/50Hz
CO
OLI
NG
Capacity - Rated kW 12.5
Capacity - Range (min ~ max) kW 2.6-14.0
Efficiency (rated) EER 3.24
Power Input (min ~ rated ~ max) kW 0.66-3.86-4.89
Operating Current (rated) A 6.74
HEA
TIN
G
Capacity - Rated kW 14.0
Capacity - Range (min ~ max) kW 2.4-18.0
Efficiency (rated) COP 3.81
Power Input (min ~ rated ~ max) kW 0.53-3.67-5.71
Operating Current (rated) A 6.74
IND
OO
R U
NIT
Dimension (HxWxD) mm 275x1400x750
Net Weight kg 40
Airflow Volume (H) L/s 583
Fan Motor Output W 250
Heating Operating Noise (Sound Pressure) (H/L) at 1m distance dBA (@spl) 40/33
Heating Operating Noise (Sound Power) (H/L) dBA (@swl) 63/54
OU
TDO
OR
UN
IT
Dimension (HxWxD) mm 1340x900x320
Net Weight kg 95
Compressor Type – DC Twin Rotary
Fan Motor Output W 100+100
Cooling Operating Noise (Sound Pressure) (H) at 1m distance dBA (@spl) 51
Cooling Operating Noise (Sound Power) (H) dBA (@swl) 68
Heating Operating Noise (Sound Pressure) (H) at 1m distance dBA (@spl) 52
Heating Operating Noise (Sound Power) (H) dBA (@swl) 69
Cooling Usable Temperature Range OC -15~46
Heating Usable Temperature Range OC -20~15
PIPE
SIZ
E
Liquid Line Ø mm 9.5
Gas Line Ø mm 15.9
Coupler Style – Flare
Maximum Length m 75
Chargeless Length m 30
Maximum Height Difference m 30
Duct Type – 3 Phase System
DEMANDRESPONSECAPABLEINVERTER AIR-CONDITIONING • DUCTED
14
InverterAllows step-less regulation of the air-conditioner’s power, which reduces energy consumption and improves comfort.
Auto-turn LouvresAir outlet grilles move automatically to fill every corner of the room with warm or cool air.
Automatic Air Volume ControlDepending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low.
Long-life FilterBuilt-in long-life filter makes maintenance easier.
Hot StartWhen using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room.
Automatic Cooling/HeatingAutomatically switches between cooling and heating mode.
DryGradually dehumidifies the room to create even greater comfort.
Filter SignAutomatic displays on the remote controller say when to perform maintenance for the indoor unit filter.
Built-in Drain PumpThe built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.)
Optional
Limit TimerUses a 168-hour timer with three modes —“ON timer”, “OFF timer” and “Repeat OFF timer”.
Cooling Capacity with an Outdoor Temperature of -15°CStable cooler operation is possible when the outdoor temperature is as low as -15°C.
123
45
60˚
123
45
30˚In cooling mode, the flap automatically swings between the top three positions.
In heating mode, the flap automatically swings between all five positions.
60˚30˚
Comfortable ambience
Very quiet operationGreatly reduces the noise level to half that of conventional units. Operation is always whisper-quiet.
Flap controlThe airflow angle is automatically set to the most suitable setting according to your cooling or heating needs, and an automatic swing mode enables airflow to reach all areas of the room to create a comfortable ambience.
Installation efficiency
Suspending the unit from the ceiling saves the complex installation procedures. It can be suspended simply by adjusting two screws on the intake grill. Compared to units which involve a dozen screws, installation is further simplified.
Comfort Operational Installation
InverterAllows step-less regulation of the air-conditioner’s power, which reduces energy consumption and improves comfort.
Auto-turn LouvresAir outlet grilles move automatically to fill every corner of the room with warm or cool air.
Automatic Air Volume ControlDepending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low.
Long-life FilterBuilt-in long-life filter makes maintenance easier.
Hot StartWhen using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room.
Automatic Cooling/HeatingAutomatically switches between cooling and heating mode.
DryGradually dehumidifies the room to create even greater comfort.
Filter SignAutomatic displays on the remote controller say when to perform maintenance for the indoor unit filter.
Built-in Drain PumpThe built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.)
Optional
Limit TimerUses a 168-hour timer with three modes —“ON timer”, “OFF timer” and “Repeat OFF timer”.
Cooling Capacity with an Outdoor Temperature of -15°CStable cooler operation is possible when the outdoor temperature is as low as -15°C.
123
45
60˚
123
45
30˚In cooling mode, the flap automatically swings between the top three positions.
In heating mode, the flap automatically swings between all five positions.
60˚30˚
InverterAllows step-less regulation of the air-conditioner’s power, which reduces energy consumption and improves comfort.
Auto-turn LouvresAir outlet grilles move automatically to fill every corner of the room with warm or cool air.
Automatic Air Volume ControlDepending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low.
Long-life FilterBuilt-in long-life filter makes maintenance easier.
Hot StartWhen using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room.
Automatic Cooling/HeatingAutomatically switches between cooling and heating mode.
DryGradually dehumidifies the room to create even greater comfort.
Filter SignAutomatic displays on the remote controller say when to perform maintenance for the indoor unit filter.
Built-in Drain PumpThe built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.)
Optional
Limit TimerUses a 168-hour timer with three modes —“ON timer”, “OFF timer” and “Repeat OFF timer”.
Cooling Capacity with an Outdoor Temperature of -15°CStable cooler operation is possible when the outdoor temperature is as low as -15°C.
123
45
60˚
123
45
30˚In cooling mode, the flap automatically swings between the top three positions.
In heating mode, the flap automatically swings between all five positions.
60˚30˚
InverterAllows step-less regulation of the air-conditioner’s power, which reduces energy consumption and improves comfort.
Auto-turn LouvresAir outlet grilles move automatically to fill every corner of the room with warm or cool air.
Automatic Air Volume ControlDepending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low.
Long-life FilterBuilt-in long-life filter makes maintenance easier.
Hot StartWhen using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room.
Automatic Cooling/HeatingAutomatically switches between cooling and heating mode.
DryGradually dehumidifies the room to create even greater comfort.
Filter SignAutomatic displays on the remote controller say when to perform maintenance for the indoor unit filter.
Built-in Drain PumpThe built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.)
Optional
Limit TimerUses a 168-hour timer with three modes —“ON timer”, “OFF timer” and “Repeat OFF timer”.
Cooling Capacity with an Outdoor Temperature of -15°CStable cooler operation is possible when the outdoor temperature is as low as -15°C.
123
45
60˚
123
45
30˚In cooling mode, the flap automatically swings between the top three positions.
In heating mode, the flap automatically swings between all five positions.
60˚30˚
RAV-SM568CTP-ERAV-SM808CTP-ERAV-SM1108CTP-ERAV-SM1408CTP-E
Models
RBC-AX33CE
Wireless remotecontroller kit (optional)
Quiet and Comfortable Ceiling Type
INVERTER AIR-CONDITIONING • CEILING
15
INDOOR RAV-SM568CTP-E RAV-SM808CTP-E RAV-SM1108CTP-E RAV-SM1408CTP-E
OUTDOOR RAV-SP564ATP-A1 RAV-SP804ATP-A1 RAV-SP1104AT-A2 RAV-SP1404AT-A2
REFRIGERANT TYPE R410A R410A R410A R410A
POWER SUPPLY/PH/FREQ Units 220-240V/1/50Hz 220-240V/1/50Hz 220-240V/1/50Hz 220-240V/1/50Hz
CO
OLI
NG
Capacity - Rated kW 5.0 7.1 10.0 12.5
Capacity - Range (min ~ max) kW 1.2~5.6 1.9~8.0 2.6~12.0 2.6~14.0
Efficiency (rated) EER 3.65 3.82 4.08 3.21
Power Input (min ~ rated ~ max) kW 0.21~1.37~2.26 0.30~1.86~2.88 0.64~2.45~3.70 0.64~3.90~4.47
Operating Current (rated) A 6.35~5.82 8.72~7.99 11.48 18.09
HEA
TIN
G
Capacity - Rated kW 5.6 8.0 11.2 14.0
Capacity - Range (min ~ max) kW 0.9~7.4 1.3~10.6 2.4~13.0 2.4~16.5
Efficiency (rated) COP 4.38 4.17 4.69 3.87
Power Input (min ~ rated ~ max) kW 0.17~1.28~2.34 0.27~1.92~3.50 0.52~2.39~4.00 0.52~3.62~4.60
Operating Current (rated) A 5.94~5.44 9.00~8.25 11.2 16.79
IND
OO
R U
NIT
Dimension (HxWxD) mm 235x950x690 235x1270x690 235x1586x690 235x1586x690
Net Weight kg 23 29 37 37
Airflow Volume (H/L) L/s 250/150 392/208 516.7/283.3 566.7/333.3
Fan Motor Output W 94 94 139 139
Heating Operating Noise (Sound Pressure) (H/M/L) at 1m distance dBA (@spl) 37/35/28 41/36/29 44/38/32 46/41/35
Heating Operating Noise (Sound Power)(H/M/L) dBA (@swl) 52/50/43 56/51/44 59/53/47 61/56/50
OU
TDO
OR
UN
IT
Dimension (HxWxD) mm 550x780x290 890x900x320 1340x900x320 1340x900x320
Net Weight kg 44 66 93 93
Compressor Type – DC Twin Rotary DC Twin Rotary DC Twin Rotary DC Twin Rotary
Fan Motor Output W 43 63 100+100 100+100
Cooling Operating Noise (Sound Pressure) (H) at 1m distance
dBA (@spl) 47 48 49 51
Cooling Operating Noise (Sound Power) (H) dBA (@swl) 63 64 66 68
Heating Operating Noise (Sound Pressure) (H) at 1m distance
dBA (@spl) 48 49 50 52
Heating Operating Noise (Sound Power) (H) dBA (@swl) 64 65 67 69
Cooling Usable Temperature Range 0C -15~43 -15~43 -15~43 -15~43
Heating Usable Temperature Range 0C -20~15 -20~15 -20~15 -20~15
PIPE
SIZ
E
Liquid Line Ø mm 6.4 9.5 9.5 9.5
Gas Line Ø mm 12.7 15.9 15.9 15.9
Coupler Style – Flare Flare Flare Flare
Drain (Inside Diameter) Ø mm VP25 VP25 VP25 VP25
Maximum Length m 50 50 75 75
Chargeless Length m 20 30 30 30
Maximum Height Difference m 30 30 30 30
Ceiling Type – Super Digital Inverter
DEMANDRESPONSECAPABLEINVERTER AIR-CONDITIONING • CEILING
16
INDOOR RAV-SM1408CTP-E RAV-SM1608CTP-E
OUTDOOR RAV-SP1404AT8-A1 RAV-SP1604AT8-A1
REFRIGERANT TYPE R410A R410A
POWER SUPPLY/PH/FREQ - (CDU) Units 380-415V/3/50Hz 380-415V/3/50Hz
CO
OLI
NG
Capacity - Rated kW 12.5 13.9
Capacity - Range (min ~ max) kW 2.5-14.0 2.6-16.0
Efficiency (rated) EER 3.36 3.28
Power Input (min ~ rated ~ max) kW 0.66 - 3.72 - 4.85 0.66-4.24-6.33
Operating Current (rated 380V-415V) A 6.50-5.95 7.16-6.55
HEA
TIN
G
Capacity - Rated kW 14.0 16.0
Capacity - Range (min ~ max) kW 2.4-18.0 2.4-19.0
Efficiency (rated) COP 3.93 3.71
Power Input (min ~ rated ~ max) kW 0.53-3.70-5.95 0.53-4.31-6.96
Operating Current (rated 380V-415V) A 6.67 7.28-6.66
IND
OO
R U
NIT
Dimension (HxWxD) mm 235x1586x690 235x1586x690
Net Weight kg 37 37
Airflow Volume (H) L/s 567 567
Fan Motor Output W 139 139
Heating Operating Noise (Sound Pressure) (H/L) at 1m distance dBA (@spl) 43/37 46/36
Heating Operating Noise (Sound Power) (H/L) dBA (@swl) 58/52 61/51
OU
TDO
OR
UN
IT
Dimension (HxWxD) mm 1340x900x320 1340x900x320
Net Weight kg 95 95
Compressor Type – DC Twin Rotary Twin Rotary
Fan Motor Output W 100+100 100+100
Cooling Operating Noise (Sound Pressure) (H) at 1m distance dBA (@spl) 51 51
Cooling Operating Noise (Sound Power) (H) dBA (@swl) 68 68
Heating Operating Noise (Sound Pressure) (H) at 1m distance dBA (@spl) 52 52
Heating Operating Noise (Sound Power) (H) dBA (@swl) 69 69
Cooling Usable Temperature Range OC -15~46 -15~46
Heating Usable Temperature Range OC -20~15 -20~15
PIPE
SIZ
E
Liquid Line Ø mm 9.5 9.5
Gas Line Ø mm 15.9 15.9
Coupler Style – Flare Flare
Maximum Length m 75 75
Chargeless Length m 30 30
Maximum Height Difference m 30 30
Ceiling Type – 3 Phase System
INVERTER AIR-CONDITIONING • CEILING
17
RAV-SM307KRTP-ARAV-SM407KRTP-ARAV-SM566KRT-ARAV-SM806KRT-A
Model
Hi-Wall Type – Twin
Features
With its attractive, slimline design, this unit is best suited for restaurants and other applications where elegance is required. The filtration system further improves the indoor air quality benefits of this Hi-Wall unit.
Key features
With its slim design, this compact and stylish unit blends into anyroom setting.
• Enhanced filtration system: Zeolite Plus + Sasa filter to deodorise, Bio-Enzyme filter + Gingko filter to purify and a new antioxidant Vitamin C filter.
• Auto-louvre mode allows optimum air distribution throughout the room.
• A wireless controller is included.
• A TCC Link remote control is optional.
InverterAllows step-less regulation of the air-conditioner’s power, which reduces energy consumption and improves comfort.
Auto-turn LouvresAir outlet grilles move automatically to fill every corner of the room with warm or cool air.
Automatic Air Volume ControlDepending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low.
Hot StartWhen using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room.
Automatic Cooling/HeatingAutomatically switches between cooling and heating mode.
DryGradually dehumidifies the room to create even greater comfort.
On/Off TimerThe operation start and stop times can be set with a digital clock.
Cooling Capacity with an Outdoor Temperature of -15°CStable cooler operation is possible when the outdoor temperature is as low as -15°C.
INDOOR RAV-SM806KRT-A x 2
OUTDOOR RAV-SP1404AT-A2
REFRIGERANT TYPE R410A
POWER SUPPLY/PH/FREQ Units 220-240V/1/50Hz
CO
OLI
NG
Capacity - Rated kW 12.3
Capacity - Range (min ~ max) kW 2.6-13.5
Efficiency (rated) EER 3.17
Power Input (min ~ rated ~ max) kW 0.64~3.88~4.40
Operating Current (rated) A 18.0
HEA
TIN
G
Capacity - Rated kW 14.0
Capacity - Range (min ~ max) kW 2.4-16.5
Efficiency (rated) COP 3.66
Power Input (min ~ rated ~ max) kW 0.52-3.83-4.60
Operating Current (rated) A 17.8
IND
OO
R U
NIT
Dimension (HxWxD) mm 320x1050x228
Net Weight kg 13
Airflow Volume (H/L) L/s 283/183
Fan Motor Output W 30
Sound Pressure (H/L) at 1m distance dBA 47/36
Sound Power (H/L) dBA 62/51
OU
TDO
OR
UN
IT
Dimension (HxWxD) mm 1340x900x320
Net Weight kg 93
Compressor Type – DC Twin Rotary
Fan Motor Output W 100+100
Cooling Operating Noise (Sound Pressure) (H) at 1m distance dBA (@spl) 51
Cooling Operating Noise (Sound Power) (H) dBA (@swl) 68
Heating Operating Noise (Sound Pressure) (H) at 1m distance dBA (@spl) 52
Heating Operating Noise (Sound Power) (H) dBA (@swl) 69
Cooling Usable Temperature Range OC -15~43
Heating Usable Temperature Range OC -20~15
PIPE
SIZ
E
Liquid Line Ø mm 9.5
Gas Line Ø mm 15.9
Coupler Style – Flare
Drain (Inside Diameter) Ø mm VP16
Maximum Length m 75
Chargeless Length m 30
Maximum Height Difference m 30
Hi-Wall Type
INVERTER AIR-CONDITIONING • HI-WALL
18
Hi-Wall Type – Digital Inverter
Comfort Operational Installation
InverterAllows step-less regulation of the air-conditioner’s power, which reduces energy consumption and improves comfort.
Auto-turn LouvresAir outlet grilles move automatically to fill every corner of the room with warm or cool air.
Automatic Air Volume ControlDepending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low.
Hot StartWhen using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room.
Automatic Cooling/HeatingAutomatically switches between cooling and heating mode.
DryGradually dehumidifies the room to create even greater comfort.
On/Off TimerThe operation start and stop times can be set with a digital clock.
Cooling Capacity with an Outdoor Temperature of -15°CStable cooler operation is possible when the outdoor temperature is as low as -15°C.
InverterAllows step-less regulation of the air-conditioner’s power, which reduces energy consumption and improves comfort.
Auto-turn LouvresAir outlet grilles move automatically to fill every corner of the room with warm or cool air.
Automatic Air Volume ControlDepending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low.
Hot StartWhen using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room.
Automatic Cooling/HeatingAutomatically switches between cooling and heating mode.
DryGradually dehumidifies the room to create even greater comfort.
On/Off TimerThe operation start and stop times can be set with a digital clock.
Cooling Capacity with an Outdoor Temperature of -15°CStable cooler operation is possible when the outdoor temperature is as low as -15°C.
InverterAllows step-less regulation of the air-conditioner’s power, which reduces energy consumption and improves comfort.
Auto-turn LouvresAir outlet grilles move automatically to fill every corner of the room with warm or cool air.
Automatic Air Volume ControlDepending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low.
Hot StartWhen using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room.
Automatic Cooling/HeatingAutomatically switches between cooling and heating mode.
DryGradually dehumidifies the room to create even greater comfort.
On/Off TimerThe operation start and stop times can be set with a digital clock.
Cooling Capacity with an Outdoor Temperature of -15°CStable cooler operation is possible when the outdoor temperature is as low as -15°C.
INDOOR RAV-SM307KRTP-A RAV-SM407KRTP-A RAV-SM566KRT-A RAV-SM806KRT-AOUTDOOR RAV-SM304ATP-A RAV-SM404ATP-A RAV-SM564ATP-A1 RAV-SM804ATP-A1REFRIGERANT TYPE R410A R410A R410A R410APOWER SUPPLY/PH/FREQ Units 220-240V/1/50Hz 220-240V/1/50Hz 220-240V/1/50Hz 220-240V/1/50Hz
CO
OLI
NG
Capacity - Rated kW 2.5 3.1 4.6 5.5Capacity - Range (min ~ max) kW 0.9 - 3.0 0.9 - 4.0 1.5 - 5.6 1.5 - 7.0Efficiency (rated) EER 4.1 3.97 3.26 3.24Star Rating – 2.5 2.5 2.0 1.5Power Input (min ~ rated ~ max) kW 0.25~0.61~0.82 0.18~0.78~2.00 0.30~1.41~1.86 0.31~1.70~2.85Operating Current (rated) A 3.07-2.83 3.85-3.55 6.85-6.40 7.95-7.45
HEA
TIN
G
Capacity - Rated kW 3.0 3.2 5.3 7.0Capacity - Range (min ~ max) kW 0.8-4.5 0.8-5.0 1.5-6.3 1.5-8.5Efficiency (rated) COP 4.23 3.95 3.42 3.33Power Input (min ~ rated ~ max) kW 19.7~58.6~85.6 10.2~40.7~85.0 0.30~1.55~2.44 0.31~2.10~3.30Operating Current (rated) A 3.33 3.80 7.50-7.05 9.84-9.20
IND
OO
R U
NIT
Dimension (HxWxD) mm 275x790x217 275x790x217 320x1050x228 320x1050x228Net Weight kg 10 10 13 13Cooling Airflow Volume (H/L) L/s 143/83 143/83 233/183 283/183Heating Airflow Volume (H/L) L/s 158/100 192/97 233/183 283/183Fan Motor Output W 30 30 30 30Sound Pressure (H/M/L) at 1m distance dBA 40/34/29 41/36/30 42/39/36 47/41/36Sound Power (H/M/L) dBA 55/49/44 56/51/45 57/54/51 62/56/51Heating Operating Noise (Sound Pressure) (H/M/L) at 1m distance
dBA (@spl) 41/37/31 45/40/32 42/39/36 47/41/36
Heating Operating Noise (Sound Power) (H/M/L) dBA (@swl) 56/52/46 60/55/47 57/54/51 62/56/51
OU
TDO
OR
UN
IT
Dimension (HxWxD) mm 550x780x290 550x780x290 550x780x290 550x780x290Net Weight kg 33 39 40 44Compressor Type – Rotary DC-Invertor Rotary DC-Invertor DC Twin Rotary DC Twin RotaryFan Motor Output W 43 43 43 43Cooling Operating Noise (Sound Pressure) (H) at 1m distance
dBA (@spl) 46 41 46 48
Cooling Operating Noise (Sound Power) (H) dBA (@swl) 61 64 63 65Heating Operating Noise (Sound Pressure) (H) at 1m distance
dBA (@spl) 47 50 48 52
Heating Operating Noise (Sound Power) (H) dBA (@swl) 62 65 65 69Cooling Usable Temperature Range ºC -15~46 -15~46 -15~46 -15~46Heating Usable Temperature Range ºC -15~24 -15~24 -15~15 -15~15
PIPE
SIZ
E
Liquid Line Ø mm 6.4 6.4 6.4 9.5Gas Line Ø mm 9.5 12.7 12.7 15.9Coupler Style – Flare Flare Flare FlareDrain (Inside Diameter) Ø mm 10.1 10.1 16 16Maximum Length m 20 20 30*1 30*2
Chargeless Length m 15 15 20 20Maximum Height Difference m 10 10 30 30
*1 21m to 30m need to extra charge 20g/m*2 21m to 30m need to extra charge 40g/m
Notes:
INVERTER AIR-CONDITIONING • HI-WALL
19
Comfort Operational Installation
InverterAllows step-less regulation of the air-conditioner’s power, which reduces energy consumption and improves comfort.
Auto-turn LouvresAir outlet grilles move automatically to fill every corner of the room with warm or cool air.
Automatic Air Volume ControlDepending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low.
Hot StartWhen using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room.
Automatic Cooling/HeatingAutomatically switches between cooling and heating mode.
DryGradually dehumidifies the room to create even greater comfort.
On/Off TimerThe operation start and stop times can be set with a digital clock.
Cooling Capacity with an Outdoor Temperature of -15°CStable cooler operation is possible when the outdoor temperature is as low as -15°C.
InverterAllows step-less regulation of the air-conditioner’s power, which reduces energy consumption and improves comfort.
Auto-turn LouvresAir outlet grilles move automatically to fill every corner of the room with warm or cool air.
Automatic Air Volume ControlDepending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low.
Hot StartWhen using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room.
Automatic Cooling/HeatingAutomatically switches between cooling and heating mode.
DryGradually dehumidifies the room to create even greater comfort.
On/Off TimerThe operation start and stop times can be set with a digital clock.
Cooling Capacity with an Outdoor Temperature of -15°CStable cooler operation is possible when the outdoor temperature is as low as -15°C.
InverterAllows step-less regulation of the air-conditioner’s power, which reduces energy consumption and improves comfort.
Auto-turn LouvresAir outlet grilles move automatically to fill every corner of the room with warm or cool air.
Automatic Air Volume ControlDepending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low.
Hot StartWhen using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room.
Automatic Cooling/HeatingAutomatically switches between cooling and heating mode.
DryGradually dehumidifies the room to create even greater comfort.
On/Off TimerThe operation start and stop times can be set with a digital clock.
Cooling Capacity with an Outdoor Temperature of -15°CStable cooler operation is possible when the outdoor temperature is as low as -15°C.
Hi-Wall Type – Super Digital Inverter
INDOOR RAV-SM566KRT-A RAV-SM806KRT-AOUTDOOR RAV-SP564ATP-A1 RAV-SP804ATP-A1REFRIGERANT TYPE R410A R410APOWER SUPPLY/PH/FREQ Units 220-240V/1/50Hz 220-240V/1/50Hz
CO
OLI
NG
Capacity - Rated kW 5.0 6.6
Capacity - Range (min ~ max) kW 1.2-5.6 1.9-8.0
Efficiency (rated) EER 3.47 3.46
Star Rating – 2.0 1.5
Power Input (min ~ rated ~ max) kW 0.21~1.44~2.05 0.30~1.91~2.88
HEA
TIN
G
Operating Current (rated) A 3.47 9.04
Capacity - Rated kW 5.6 8.0
Capacity - Range (min ~ max) kW 0.9-7.3 1.3-10.6
Efficiency (rated) COP 3.73 3.42
Star Rating – 2.5 1.5
Power Input (min ~ rated ~ max) kW 0.17~1.50~2.57 0.27~2.34~3.87
Operating Current (rated) A 6.98 9.04
IND
OO
R U
NIT
Dimension (HxWxD) mm 320x1050x228 320x1050x228
Net Weight kg 12 12
Airflow Volume (H/L) L/s 233/183 283/183
Fan Motor Output W 30 30
Heating Operating Noise (sound pressure) (H/M/L/) at 1m distance dBA 42/39/36 47/41/36
Heating Operating Noise (sound power) (H/M/L) dBA 57/54/51 62/56/51
Cooling Usable Temperature Range ºC 21-32 21-32
Heating Usable Temperature Range ºC 15-24 15-24
OU
TDO
OR
UN
IT
Dimension (HxWxD) mm 550x780x290 890x900x320
Net Weight kg 44 66
Compressor Type – DC Twin Rotary DC Twin Rotary
Fan Motor Output W 43 63
Cooling Operating Noise (Sound Pressure) (H) at 1m distance dBA (@spl) 47 48
Cooling Operating Noise (Sound Power) (H) dBA (@swl) 63 64
Heating Operating Noise (Sound Pressure) (H) at 1m distance dBA (@spl) 48 49
Heating Operating Noise (Sound Power) (H) dBA (@swl) 64 65
Cooling Usable Temperature Range ºC -15~43 -15~43
Heating Usable Temperature Range ºC -20~15 -20~15
PIPE
SIZ
E
Liquid Line Ø mm 6.4 9.5
Gas Line Ø mm 12.7 15.9
Coupler Style – Flare Flare
Drain (Inside Diameter) Ø mm VP16 VP16
Maximum Length m 50 50
Chargeless Length m 20 30
Maximum Height Difference m 30 30
DEMANDRESPONSECAPABLEINVERTER AIR-CONDITIONING • HI-WALL
20
Wired controller Backlit wired controller IntesisHome WiFi Controller
APPEARANCE
MODEL NAME RBC-AMT32E & RBC-AMS41E RBC-AMS54E-ES TO-RC-WIFI-1*
Controllers
COMBINATIONS
Wireless controller kits
APPEARANCE
MODEL NAME RBC-AX32U(W)-E RBC-AX33CE TCB-AX32E2
REMARKS For 4-way cassette type For under ceiling type Suitable for all models
Integral receiver Integral receiver
Standalone receiver
COMBINATIONS
WIRED WIFI WIRELESSRBC-AMT32E RBC-AMS41E RBC-AMS54E-ES TO-RC-WIFI-1* RBC-AX32U(W)-E RBC-AX33CE TCB-AX32E2
Compact 4-way Cassette Series 4 RAV-SM564MUT-E OK OK OK OK OK
4-way Cassette Series 4
RAV-SM564UTP-E OK OK OK OK OK OK
RAV-SM804UTP-E OK OK OK OK OK OK
RAV-SM1104UTP-E OK OK OK OK OK OK
RAV-SM1404UTP-E OK OK OK OK OK OK
RAV-SM1604UTP-E OK OK OK OK OK OK
Duct Series 6
RAV-SM566BTP-E OK OK OK OK OK
RAV-SM806BTP-E OK OK OK OK OK
RAV-SM1106BTP-E OK OK OK OK OK
RAV-SM1406BTP-E OK OK OK OK OK
Ceiling Series 7
RAV-SM567CTP-E OK OK OK OK OK OK
RAV-SM807CTP-E OK OK OK OK OK OK
RAV-SM1107CTP-E OK OK OK OK OK OK
RAV-SM1407CTP-E OK OK OK OK OK OK
High-wall Series 6 & 7
RAV-SM566KRT-A OK OK OK OK OK
RAV-SM806KRT-A OK OK OK OK OK
RAV-SM307KRTP-A OK OK OK OK OK
RAV-SM407KRTP-A OK OK OK OK OK
INVERTER AIR-CONDITIONING • CONTROLLERS
*TO-RC-WIFI-1 is not compatible with the RBC-AMS54E-ESNotes:
21
SDI – Super Digital Inverter
Very efficient energy consumption• Keeps down operating costs
DI – Digital Inverter
Lightweight and compact outdoor unit• Reduces installation space and enables a more efficient use of the site
• Keeps down delivery costs
• Easy to install on a wall
Heater operation is possible starting from an outdoor temperature of –20˚C (RAV-SP1104AT-A, RAV-SP1404AT-A)
• Creates a comfortable space even during cold winters
Compatible with pipes up to 75 metres long (RAV-SP1104AT-A, RAV-SP1404AT-A)
• Enables the outdoor unit to be installed out of sight increases installation flexibility
Low-noise design. If the outdoor temperature is 30˚C or less, operates at under 45 dB
Operation in Power Save Mode enables power peaks to be cut
INVERTER AIR-CONDITIONING • SDI/DI
22
Indoor Units
Units: mm
Ceiling Hi Wall
Duct
4-way cassette
Z view
155
28.5
6157
6418
7
32
Bottom face of ceiling
Knockout for fresh air intake dia.150
300 or less
Sta
nd-u
p66
1 or
less
*
Sta
nd-u
p 85
0 or
less
Bottom face of ceiling
Bottom face of ceiling
Drain-up standing-up size
860 to 910 Ceiling open dimension
860
to 9
10 C
eilin
g op
en d
imen
sion
Ceiling panel (Sold separately)
Refrigerant pipe connecting port (Gas side)
Refrigerant pipe connecting port (Liquid side)
Hanging bolt M10 orW3/8 local arrange
Drain discharge port
For branch duct knockout square hole 150 (diam.)
For branch duct knockout square hole 150 (diam.) (Also located on the back)
*( ): 110–140 type
129
132 25
6
3010
1
16.5
351
480
256.5
196.5
38435 105
223.5
163.5
7774
105
(183
)*
120
*(13
7)
*(31
9)
1000 or more 1000 or more
15 o
r mor
e
15 o
r mor
e
1000
or
mor
e
Space required for installation
241.5263
397.5
129
189
337.5
30
105
72 106.5
172
112
44
157
Wiring connection port
Z 45
950
Pan
el e
xter
nal d
imen
sion
780
Han
ging
bol
t p
itch
416.5
408
69020 Hanging bolt pitch
950 Panel external dimension
269
323
Electric parts box
A 7.5 Hanging bolt pitch 700 Hanging bolt pitch
B
252C1C1
F-dia.200
dia.26 wiring connection port
Drain pipe connecting port(Inner dia.32, VP25)
dia.125 knockout hole (backside)(for fresh air intake)
Long life filter
Hanging bolt 4-M10 local arrange
80075
41 5963850
49839341
50 243
174
275
131
50
Refrigerant pipe connecting port (Gas side)
Refrigerant pipe connecting port (Liquid side)
56 type
80 type
110–140 type
ACapacity class
766
1066
1416
700
1000
1350
B
280
290
310
C
(mm)
Refrigerant pipe connecting port (Gas side)
Refrigerant pipe connecting port (Liquid side)
Piping port from bottom sides *
Piping port from left sides * Piping port
from left sides *
Installation plate hole location
4-way air Discharge Cassete Type
Mode l name
MMU-AP0151MHMMU-AP0181MH
MMU-AP0071MHMMU-AP0091MHMMU-AP0121MH
Arialb1i0c0p34;TOSHIBA CARRIER CORPORATION
For branch duct knockout square hole dia.150
Knockout for flesh air intake dia.100
700
Pan
el e
xter
nal d
imen
sion
595
to 6
60 c
eilin
g op
en d
imen
sion
525
hang
ing
bol
t p
itch
Bottom face of ceiling
Electricparts box 575 unit external dimension
177
Bottom face of ceiling
235 235
207
29
175149
64
70.5
142
6436
8.5
320.
5
Refrigerant pipe (Gas)0151, 0181MH............dia.12.70071, 0091, 0121MH..dia.9.5
97.5
70.5
105
55
63 134
145.
5
220.
5
268
27
93139.
519
0.5
214O/ 162256105
42
142120
15821
148Refrigerant pipe (Liquid) dia.6.4
Wiring connection port
575
unit
exte
rnal
dim
ensi
on
331.
5
510 hanging bolt pitch595 to 660 ceiling open dimension700 Panel external dimension
Hanging boltM10 or W3/8 local arrange
Drain discharge port
Bottom face of ceiling
Ceiling panel
105
93
145.
5
105
dia.162
For branch duct knockout square hole dia.150
Indoor unit
595
to 6
60 c
eilin
g op
en d
imen
sion
1000
or
mor
e
15 o
r m
ore
15 o
r m
ore
1000 or more 1000 or more
Obstacle
595 to 660 ceiling open dimension
Bottom faceof ceiling 20
0
Sta
nd-u
p82
7.5
or le
ss
Sta
nd-u
p85
0 or
less
300
Check port( 450)
Space required for installation
Drain-up standing-up size
56 type
80 type
120 to 140 type
ACapacity class
855
1125
1540
910
1180
1595
B
(mm)
B
(Han
ging
p
ositi
on)
A (Hanging position)
Refrigerant pipe (Gas side)
Wireless sensor mounting section
Piping hole on the wall (dia.100 hole)
Drain pipe connecting port
Air intake port dia.92 *(Duct sold separately)
Drain left piping extake port *
Remote controller cable intake port *
Remote controller cable intake port *
Piping extake port *
Drain port VP20(Inner dia.62, hose supplied)
Power supply intake port *Refrigerant pipe (Liquid side)
170
320
84
128
Left drain size
Remote controller piping intake port *
Power supply cable intake port *
Upper piping extake port *
110 5013
0
216
146
75 97
76
53 70
135
171
90 32 92
145
347
3284
262
Z view
Space required for installation and servicing
(Front side to bepositioned horizontally)
250 or more
250 or more
500
or
mor
e
Ceiling surface
Unit
With
in 5
0
Hanging bolt
680
167105
114
141
210
200
(Liq
uid
pip
e)21
6 (G
as p
ipe) * : Knockout hole
* : Knockout hole
Z
Air outlet Air inlet
Drain hose VP16
40
110 390490540
115 100 115100
763.5998
298
221998
75
50
75 56
51
75
50
87
40
Space required for service
53 or more 53 or more 55 o
r mor
e
Compact 4-way cassette
Z view
155
28.5
6157
6418
7
32
Bottom face of ceiling
Knockout for fresh air intake dia.150
300 or less
Sta
nd-u
p66
1 or
less
*
Sta
nd-u
p 85
0 or
less
Bottom face of ceiling
Bottom face of ceiling
Drain-up standing-up size
860 to 910 Ceiling open dimension
860
to 9
10 C
eilin
g op
en d
imen
sion
Ceiling panel (Sold separately)
Refrigerant pipe connecting port (Gas side)
Refrigerant pipe connecting port (Liquid side)
Hanging bolt M10 orW3/8 local arrange
Drain discharge port
For branch duct knockout square hole 150 (diam.)
For branch duct knockout square hole 150 (diam.) (Also located on the back)
*( ): 110–140 type
129
132 25
6
3010
1
16.5
351
480
256.5
196.5
38435 105
223.5
163.5
7774
105
(183
)*
120
*(13
7)
*(31
9)
1000 or more 1000 or more
15 o
r mor
e
15 o
r mor
e
1000
or
mor
e
Space required for installation
241.5263
397.5
129
189
337.5
30
105
72 106.5
172
112
44
157
Wiring connection port
Z 45
950
Pan
el e
xter
nal d
imen
sion
780
Han
ging
bol
t p
itch
416.5
408
69020 Hanging bolt pitch
950 Panel external dimension
269
323
Electric parts box
A 7.5 Hanging bolt pitch 700 Hanging bolt pitch
B
252C1C1
F-dia.200
dia.26 wiring connection port
Drain pipe connecting port(Inner dia.32, VP25)
dia.125 knockout hole (backside)(for fresh air intake)
Long life filter
Hanging bolt 4-M10 local arrange
80075
41 5963850
49839341
50 243
174
275
131
50
Refrigerant pipe connecting port (Gas side)
Refrigerant pipe connecting port (Liquid side)
56 type
80 type
110–140 type
ACapacity class
766
1066
1416
700
1000
1350
B
280
290
310
C
(mm)
Refrigerant pipe connecting port (Gas side)
Refrigerant pipe connecting port (Liquid side)
Piping port from bottom sides *
Piping port from left sides * Piping port
from left sides *
Installation plate hole location
4-way air Discharge Cassete Type
Mode l name
MMU-AP0151MHMMU-AP0181MH
MMU-AP0071MHMMU-AP0091MHMMU-AP0121MH
Arialb1i0c0p34;TOSHIBA CARRIER CORPORATION
For branch duct knockout square hole dia.150
Knockout for flesh air intake dia.100
700
Pan
el e
xter
nal d
imen
sion
595
to 6
60 c
eilin
g op
en d
imen
sion
525
hang
ing
bol
t p
itch
Bottom face of ceiling
Electricparts box 575 unit external dimension
177
Bottom face of ceiling
235 235
207
29
175149
64
70.5
142
6436
8.5
320.
5
Refrigerant pipe (Gas)0151, 0181MH............dia.12.70071, 0091, 0121MH..dia.9.5
97.5
70.5
105
55
63 134
145.
5
220.
5
268
27
93139.
519
0.5
214O/ 162256105
42
142120
15821
148Refrigerant pipe (Liquid) dia.6.4
Wiring connection port
575
unit
exte
rnal
dim
ensi
on
331.
5
510 hanging bolt pitch595 to 660 ceiling open dimension700 Panel external dimension
Hanging boltM10 or W3/8 local arrange
Drain discharge port
Bottom face of ceiling
Ceiling panel
105
93
145.
5
105
dia.162
For branch duct knockout square hole dia.150
Indoor unit
595
to 6
60 c
eilin
g op
en d
imen
sion
1000
or
mor
e
15 o
r m
ore
15 o
r m
ore
1000 or more 1000 or more
Obstacle
595 to 660 ceiling open dimension
Bottom faceof ceiling 20
0
Sta
nd-u
p82
7.5
or le
ss
Sta
nd-u
p85
0 or
less
300
Check port( 450)
Space required for installation
Drain-up standing-up size
56 type
80 type
120 to 140 type
ACapacity class
855
1125
1540
910
1180
1595
B
(mm)
B
(Han
ging
p
ositi
on)
A (Hanging position)
Refrigerant pipe (Gas side)
Wireless sensor mounting section
Piping hole on the wall (dia.100 hole)
Drain pipe connecting port
Air intake port dia.92 *(Duct sold separately)
Drain left piping extake port *
Remote controller cable intake port *
Remote controller cable intake port *
Piping extake port *
Drain port VP20(Inner dia.62, hose supplied)
Power supply intake port *Refrigerant pipe (Liquid side)
170
320
84
128
Left drain size
Remote controller piping intake port *
Power supply cable intake port *
Upper piping extake port *
110 5013
0
216
146
75 97
76
53 70
135
171
90 32 92
145
347
3284
262
Z view
Space required for installation and servicing
(Front side to bepositioned horizontally)
250 or more
250 or more
500
or
mor
e
Ceiling surface
Unit
With
in 5
0
Hanging bolt
680
167105
114
141
210
200
(Liq
uid
pip
e)21
6 (G
as p
ipe) * : Knockout hole
* : Knockout hole
Z
Air outlet Air inlet
Drain hose VP16
40
110 390490540
115 100 115100
763.5998
298
221998
75
50
75 56
51
75
50
87
40
Space required for service
53 or more 53 or more 55 o
r mor
e
Z view
155
28.5
6157
6418
7
32
Bottom face of ceiling
Knockout for fresh air intake dia.150
300 or less
Sta
nd-u
p66
1 or
less
*
Sta
nd-u
p 85
0 or
less
Bottom face of ceiling
Bottom face of ceiling
Drain-up standing-up size
860 to 910 Ceiling open dimension
860
to 9
10 C
eilin
g op
en d
imen
sion
Ceiling panel (Sold separately)
Refrigerant pipe connecting port (Gas side)
Refrigerant pipe connecting port (Liquid side)
Hanging bolt M10 orW3/8 local arrange
Drain discharge port
For branch duct knockout square hole 150 (diam.)
For branch duct knockout square hole 150 (diam.) (Also located on the back)
*( ): 110–140 type12
9
132 25
6
3010
1
16.5
351
480
256.5
196.5
38435 105
223.5
163.5
7774
105
(183
)*
120
*(13
7)
*(31
9)
1000 or more 1000 or more
15 o
r mor
e
15 o
r mor
e
1000
or
mor
e
Space required for installation
241.5263
397.5
129
189
337.5
30
105
72 106.5
172
112
44
157
Wiring connection port
Z 45
950
Pan
el e
xter
nal d
imen
sion
780
Han
ging
bol
t p
itch
416.5
408
69020 Hanging bolt pitch
950 Panel external dimension
269
323
Electric parts box
A 7.5 Hanging bolt pitch 700 Hanging bolt pitch
B
252C1C1
F-dia.200
dia.26 wiring connection port
Drain pipe connecting port(Inner dia.32, VP25)
dia.125 knockout hole (backside)(for fresh air intake)
Long life filter
Hanging bolt 4-M10 local arrange
80075
41 5963850
49839341
50 243
174
275
131
50
Refrigerant pipe connecting port (Gas side)
Refrigerant pipe connecting port (Liquid side)
56 type
80 type
110–140 type
ACapacity class
766
1066
1416
700
1000
1350
B
280
290
310
C
(mm)
Refrigerant pipe connecting port (Gas side)
Refrigerant pipe connecting port (Liquid side)
Piping port from bottom sides *
Piping port from left sides * Piping port
from left sides *
Installation plate hole location
4-way air Discharge Cassete Type
Mode l name
MMU-AP0151MHMMU-AP0181MH
MMU-AP0071MHMMU-AP0091MHMMU-AP0121MH
Arialb1i0c0p34;TOSHIBA CARRIER CORPORATION
For branch duct knockout square hole dia.150
Knockout for flesh air intake dia.100
700
Pan
el e
xter
nal d
imen
sion
595
to 6
60 c
eilin
g op
en d
imen
sion
525
hang
ing
bol
t p
itch
Bottom face of ceiling
Electricparts box 575 unit external dimension
177
Bottom face of ceiling
235 235
207
29
175149
64
70.5
142
6436
8.5
320.
5
Refrigerant pipe (Gas)0151, 0181MH............dia.12.70071, 0091, 0121MH..dia.9.5
97.5
70.5
105
55
63 134
145.
5
220.
5
268
27
93139.
519
0.5
214O/ 162256105
42
142120
15821
148Refrigerant pipe (Liquid) dia.6.4
Wiring connection port
575
unit
exte
rnal
dim
ensi
on
331.
5
510 hanging bolt pitch595 to 660 ceiling open dimension700 Panel external dimension
Hanging boltM10 or W3/8 local arrange
Drain discharge port
Bottom face of ceiling
Ceiling panel
105
93
145.
5
105
dia.162
For branch duct knockout square hole dia.150
Indoor unit
595
to 6
60 c
eilin
g op
en d
imen
sion
1000
or
mor
e
15 o
r m
ore
15 o
r m
ore
1000 or more 1000 or more
Obstacle
595 to 660 ceiling open dimension
Bottom faceof ceiling 20
0
Sta
nd-u
p82
7.5
or le
ss
Sta
nd-u
p85
0 or
less
300
Check port( 450)
Space required for installation
Drain-up standing-up size
56 type
80 type
120 to 140 type
ACapacity class
855
1125
1540
910
1180
1595
B
(mm)
B
(Han
ging
p
ositi
on)
A (Hanging position)
Refrigerant pipe (Gas side)
Wireless sensor mounting section
Piping hole on the wall (dia.100 hole)
Drain pipe connecting port
Air intake port dia.92 *(Duct sold separately)
Drain left piping extake port *
Remote controller cable intake port *
Remote controller cable intake port *
Piping extake port *
Drain port VP20(Inner dia.62, hose supplied)
Power supply intake port *Refrigerant pipe (Liquid side)
170
320
84
128
Left drain size
Remote controller piping intake port *
Power supply cable intake port *
Upper piping extake port *
110 5013
0
216
146
75 97
76
53 70
135
171
90 32 92
145
347
3284
262
Z view
Space required for installation and servicing
(Front side to bepositioned horizontally)
250 or more
250 or more
500
or
mor
e
Ceiling surface
Unit
With
in 5
0
Hanging bolt
680
167105
114
141
210
200
(Liq
uid
pip
e)21
6 (G
as p
ipe) * : Knockout hole
* : Knockout hole
Z
Air outlet Air inlet
Drain hose VP16
40
110 390490540
115 100 115100
763.5998
298
221998
75
50
75 56
51
75
50
87
40
Space required for service
53 or more 53 or more 55 o
r mor
e
Z view
155
28.5
6157
6418
7
32
Bottom face of ceiling
Knockout for fresh air intake dia.150
300 or less
Sta
nd-u
p66
1 or
less
*
Sta
nd-u
p 85
0 or
less
Bottom face of ceiling
Bottom face of ceiling
Drain-up standing-up size
860 to 910 Ceiling open dimension
860
to 9
10 C
eilin
g op
en d
imen
sion
Ceiling panel (Sold separately)
Refrigerant pipe connecting port (Gas side)
Refrigerant pipe connecting port (Liquid side)
Hanging bolt M10 orW3/8 local arrange
Drain discharge port
For branch duct knockout square hole 150 (diam.)
For branch duct knockout square hole 150 (diam.) (Also located on the back)
*( ): 110–140 type
129
132 25
6
3010
1
16.5
351
480
256.5
196.5
38435 105
223.5
163.5
7774
105
(183
)*
120
*(13
7)
*(31
9)
1000 or more 1000 or more
15 o
r mor
e
15 o
r mor
e
1000
or
mor
e
Space required for installation
241.5263
397.5
129
189
337.5
30
105
72 106.5
172
112
44
157
Wiring connection port
Z 45
950
Pan
el e
xter
nal d
imen
sion
780
Han
ging
bol
t p
itch
416.5
408
69020 Hanging bolt pitch
950 Panel external dimension
269
323
Electric parts box
A 7.5 Hanging bolt pitch 700 Hanging bolt pitch
B
252C1C1
F-dia.200
dia.26 wiring connection port
Drain pipe connecting port(Inner dia.32, VP25)
dia.125 knockout hole (backside)(for fresh air intake)
Long life filter
Hanging bolt 4-M10 local arrange
80075
41 5963850
49839341
50 243
174
275
131
50
Refrigerant pipe connecting port (Gas side)
Refrigerant pipe connecting port (Liquid side)
56 type
80 type
110–140 type
ACapacity class
766
1066
1416
700
1000
1350
B
280
290
310
C
(mm)
Refrigerant pipe connecting port (Gas side)
Refrigerant pipe connecting port (Liquid side)
Piping port from bottom sides *
Piping port from left sides * Piping port
from left sides *
Installation plate hole location
4-way air Discharge Cassete Type
Mode l name
MMU-AP0151MHMMU-AP0181MH
MMU-AP0071MHMMU-AP0091MHMMU-AP0121MH
Arialb1i0c0p34;TOSHIBA CARRIER CORPORATION
For branch duct knockout square hole dia.150
Knockout for flesh air intake dia.100
700
Pan
el e
xter
nal d
imen
sion
595
to 6
60 c
eilin
g op
en d
imen
sion
525
hang
ing
bol
t p
itch
Bottom face of ceiling
Electricparts box 575 unit external dimension
177
Bottom face of ceiling
235 235
207
29
175149
64
70.5
142
6436
8.5
320.
5
Refrigerant pipe (Gas)0151, 0181MH............dia.12.70071, 0091, 0121MH..dia.9.5
97.5
70.5
105
55
63 134
145.
5
220.
5
268
27
93139.
519
0.5
214O/ 162256105
42
142120
15821
148Refrigerant pipe (Liquid) dia.6.4
Wiring connection port
575
unit
exte
rnal
dim
ensi
on
331.
5
510 hanging bolt pitch595 to 660 ceiling open dimension700 Panel external dimension
Hanging boltM10 or W3/8 local arrange
Drain discharge port
Bottom face of ceiling
Ceiling panel
105
93
145.
5
105
dia.162
For branch duct knockout square hole dia.150
Indoor unit
595
to 6
60 c
eilin
g op
en d
imen
sion
1000
or
mor
e
15 o
r m
ore
15 o
r m
ore
1000 or more 1000 or more
Obstacle
595 to 660 ceiling open dimension
Bottom faceof ceiling 20
0
Sta
nd-u
p82
7.5
or le
ss
Sta
nd-u
p85
0 or
less
300
Check port( 450)
Space required for installation
Drain-up standing-up size
56 type
80 type
120 to 140 type
ACapacity class
855
1125
1540
910
1180
1595
B
(mm)
B
(Han
ging
p
ositi
on)
A (Hanging position)
Refrigerant pipe (Gas side)
Wireless sensor mounting section
Piping hole on the wall (dia.100 hole)
Drain pipe connecting port
Air intake port dia.92 *(Duct sold separately)
Drain left piping extake port *
Remote controller cable intake port *
Remote controller cable intake port *
Piping extake port *
Drain port VP20(Inner dia.62, hose supplied)
Power supply intake port *Refrigerant pipe (Liquid side)
170
320
84
128
Left drain size
Remote controller piping intake port *
Power supply cable intake port *
Upper piping extake port *
110 5013
0
216
146
75 97
76
53 70
135
171
90 32 92
145
347
3284
262
Z view
Space required for installation and servicing
(Front side to bepositioned horizontally)
250 or more
250 or more
500
or
mor
e
Ceiling surface
Unit
With
in 5
0
Hanging bolt
680
167105
114
141
210
200
(Liq
uid
pip
e)21
6 (G
as p
ipe) * : Knockout hole
* : Knockout hole
Z
Air outlet Air inlet
Drain hose VP16
40
110 390490540
115 100 115100
763.5998
298
221998
75
50
75 56
51
75
50
87
40
Space required for service
53 or more 53 or more 55 o
r mor
e
Z view
155
28.5
6157
6418
7
32
Bottom face of ceiling
Knockout for fresh air intake dia.150
300 or less
Sta
nd-u
p66
1 or
less
*
Sta
nd-u
p 85
0 or
less
Bottom face of ceiling
Bottom face of ceiling
Drain-up standing-up size
860 to 910 Ceiling open dimension
860
to 9
10 C
eilin
g op
en d
imen
sion
Ceiling panel (Sold separately)
Refrigerant pipe connecting port (Gas side)
Refrigerant pipe connecting port (Liquid side)
Hanging bolt M10 orW3/8 local arrange
Drain discharge port
For branch duct knockout square hole 150 (diam.)
For branch duct knockout square hole 150 (diam.) (Also located on the back)
*( ): 110–140 type
129
132 25
6
3010
1
16.5
351
480
256.5
196.5
38435 105
223.5
163.5
7774
105
(183
)*
120
*(13
7)
*(31
9)
1000 or more 1000 or more
15 o
r mor
e
15 o
r mor
e
1000
or
mor
e
Space required for installation
241.5263
397.512
918
9337.5
30
105
72 106.5
172
112
44
157
Wiring connection port
Z 45
950
Pan
el e
xter
nal d
imen
sion
780
Han
ging
bol
t p
itch
416.5
408
69020 Hanging bolt pitch
950 Panel external dimension
269
323
Electric parts box
A 7.5 Hanging bolt pitch 700 Hanging bolt pitch
B
252C1C1
F-dia.200
dia.26 wiring connection port
Drain pipe connecting port(Inner dia.32, VP25)
dia.125 knockout hole (backside)(for fresh air intake)
Long life filter
Hanging bolt 4-M10 local arrange
80075
41 5963850
49839341
50 243
174
275
131
50
Refrigerant pipe connecting port (Gas side)
Refrigerant pipe connecting port (Liquid side)
56 type
80 type
110–140 type
ACapacity class
766
1066
1416
700
1000
1350
B
280
290
310
C
(mm)
Refrigerant pipe connecting port (Gas side)
Refrigerant pipe connecting port (Liquid side)
Piping port from bottom sides *
Piping port from left sides * Piping port
from left sides *
Installation plate hole location
4-way air Discharge Cassete Type
Mode l name
MMU-AP0151MHMMU-AP0181MH
MMU-AP0071MHMMU-AP0091MHMMU-AP0121MH
Arialb1i0c0p34;TOSHIBA CARRIER CORPORATION
For branch duct knockout square hole dia.150
Knockout for flesh air intake dia.100
700
Pan
el e
xter
nal d
imen
sion
595
to 6
60 c
eilin
g op
en d
imen
sion
525
hang
ing
bol
t p
itch
Bottom face of ceiling
Electricparts box 575 unit external dimension
177
Bottom face of ceiling
235 235
207
29
175149
64
70.5
142
6436
8.5
320.
5
Refrigerant pipe (Gas)0151, 0181MH............dia.12.70071, 0091, 0121MH..dia.9.5
97.5
70.5
105
55
63 134
145.
5
220.
5
268
27
93139.
519
0.5
214O/ 162256105
42
142120
15821
148Refrigerant pipe (Liquid) dia.6.4
Wiring connection port
575
unit
exte
rnal
dim
ensi
on
331.
5
510 hanging bolt pitch595 to 660 ceiling open dimension700 Panel external dimension
Hanging boltM10 or W3/8 local arrange
Drain discharge port
Bottom face of ceiling
Ceiling panel
105
93
145.
5
105
dia.162
For branch duct knockout square hole dia.150
Indoor unit
595
to 6
60 c
eilin
g op
en d
imen
sion
1000
or
mor
e
15 o
r m
ore
15 o
r m
ore
1000 or more 1000 or more
Obstacle
595 to 660 ceiling open dimension
Bottom faceof ceiling 20
0
Sta
nd-u
p82
7.5
or le
ss
Sta
nd-u
p85
0 or
less
300
Check port( 450)
Space required for installation
Drain-up standing-up size
56 type
80 type
120 to 140 type
ACapacity class
855
1125
1540
910
1180
1595
B
(mm)
B
(Han
ging
p
ositi
on)
A (Hanging position)
Refrigerant pipe (Gas side)
Wireless sensor mounting section
Piping hole on the wall (dia.100 hole)
Drain pipe connecting port
Air intake port dia.92 *(Duct sold separately)
Drain left piping extake port *
Remote controller cable intake port *
Remote controller cable intake port *
Piping extake port *
Drain port VP20(Inner dia.62, hose supplied)
Power supply intake port *Refrigerant pipe (Liquid side)
170
320
84
128
Left drain size
Remote controller piping intake port *
Power supply cable intake port *
Upper piping extake port *
110 5013
0
216
146
75 97
76
53 70
135
171
90 32 92
145
347
3284
262
Z view
Space required for installation and servicing
(Front side to bepositioned horizontally)
250 or more
250 or more
500
or
mor
e
Ceiling surface
Unit
With
in 5
0
Hanging bolt
680
167105
114
141
210
200
(Liq
uid
pip
e)21
6 (G
as p
ipe) * : Knockout hole
* : Knockout hole
Z
Air outlet Air inlet
Drain hose VP16
40
110 390490540
115 100 115100
763.5998
298
221998
75
50
75 56
51
75
50
87
40
Space required for service
53 or more 53 or more 55 o
r mor
e
INVERTER AIR-CONDITIONING • INDOOR UNITS
23
Outdoor Units
Units: mm
RAV-SM564AT-A1 ~ RAV-SM804AT-A1
RAV-SP564ATP-A1 ~ RAV-SP804ATP-A1, RAV-SM1104ATP-A1 ~ RAV-SM1404ATP-A1
RAV-SP1104AT-A2 ~ RAV-SP1404AT-A2
Refrigerant pipe connecting port (Gas side)
Refrigerant pipe connecting port (Liquid side)
Refrigerant pipe connecting port (Gas side)
Knockout for lower piping
Refrigerant pipe connecting port (Liquid side)
Refrigerant pipe connecting port (Gas side)
Hanger (both sides)
Refrigerant pipe connecting port (Liquid side)
Mounting bolt hole(dia.12x17 U-shape cut-out)
Mounting bolt hole(dia.12x17 long hole)
8-dia.6 hole (for fixing outdoor unit)
Charging port
Mounting bolt hole(2-dia.12x17 U-shape cut-out)
Mounting bolt hole(2-dia.12x17 long hole)
Drain hole dia.25
(Anc
hor
bolt
long
hol
e pi
tch)
(Anc
hor b
olt
long
hol
e pi
tch)
(dia
.6 h
ole
pitc
h)
B leg part
b leg part
a leg part
A leg part
B leg part
A leg part
Air outlet
Air inlet Drain hole (dia.25)
SDI DI56 ~ 80 type 110 ~ 140 type
Drain hole (dia.20x88)
Knock out(for drain)
Knockout(for drain)
Knockout for lower piping
: SDI 80 type
Air
inle
t
2-dia.11x14 long hole (for dia.8–10 anchor bolt)
2-dia.11x14 U-shape cut-out (for dia.8–10 anchor bolt)
2-dia.20x88 drain long hole
2-dia.6 hole
Detailed A leg part
Detailed A leg part
Detailed B leg part
Detailed b leg part
Detailed a leg part
Detailed B leg part
Fan guard
2-dia.6 hole
60 30
20
30
54
600
108 125
9038
54
R5.5
R15
14769.5 2155
0
483
320
306
290
635
449
365
17.5
17.5
137
93
52
8 500
483108
257
32
2522
71780
38
54
R5.5
R15
11
145
342
157 79
21
14331
54
36 (43)
95
52
600
29 90 20191
150602621
4021
70
(47)
39
43 40
5-drain hole (dia.20x88)
Drain hole (dia.25)
900
314550
270
43
95
39 47
17.5
40
40
28
17.5
320
45 5025F
G30
DI (110–140 type)
SDI: 80 type
Z view
Z
Z view
Z
300
565
101
307
6096
27
B
C
6067
154 D E
254
518
534
250
86 7
587
27 58
46
161400
B
B
F G
C
C60
2590
8979
5
165
608026
4
Air inlet
Air inlet
Air outlet
Air
inle
t
Air outlet
Air
inle
tSpace required for service
150 or more
150 or more500 or more
300 or more
SDI
SDI / DI
BC
Power supply wiring hole dia.38 knockout hole
DE
269282
264
56–140 typeName
56 type 80 type
90052 550
40
40
12
9639
48 54
60070
34
75
46 170
60380
200
17.5
128
118
74 38315017
.536
5
18 80
151400
55
24
95
9413
40
30 320
65
83 7
7
5595
1880
135
155
613
605
7058
174
581
178 178 178
518
360
655
327
60
68
534
121
534
85
B
C
9555
12 64
C
B
C
Piping drawing port
Refrigerant pipe connecting port (Gas side)
Refrigerant pipe connecting port (Liquid side)
Refrigerant pipe connecting port (Gas side)
Knockout for lower piping
Refrigerant pipe connecting port (Liquid side)
Refrigerant pipe connecting port (Gas side)
Hanger (both sides)
Refrigerant pipe connecting port (Liquid side)
Mounting bolt hole(dia.12x17 U-shape cut-out)
Mounting bolt hole(dia.12x17 long hole)
8-dia.6 hole (for fixing outdoor unit)
Charging port
Mounting bolt hole(2-dia.12x17 U-shape cut-out)
Mounting bolt hole(2-dia.12x17 long hole)
Drain hole dia.25
(Anc
hor
bolt
long
hol
e pi
tch)
(Anc
hor b
olt
long
hol
e pi
tch)
(dia
.6 h
ole
pitc
h)
B leg part
b leg part
a leg part
A leg part
B leg part
A leg part
Air outlet
Air inlet Drain hole (dia.25)
SDI DI56 ~ 80 type 110 ~ 140 type
Drain hole (dia.20x88)
Knock out(for drain)
Knockout(for drain)
Knockout for lower piping
: SDI 80 type
Air
inle
t
2-dia.11x14 long hole (for dia.8–10 anchor bolt)
2-dia.11x14 U-shape cut-out (for dia.8–10 anchor bolt)
2-dia.20x88 drain long hole
2-dia.6 hole
Detailed A leg part
Detailed A leg part
Detailed B leg part
Detailed b leg part
Detailed a leg part
Detailed B leg part
Fan guard
2-dia.6 hole
60 30
20
30
54
600
108 125
9038
54
R5.5
R15
14769.5 2155
0
483
320
306
290
635
449
365
17.5
17.5
137
93
52
8 500
483108
257
32
2522
71780
38
54
R5.5
R15
11
145
342
157 79
21
14331
54
36 (43)
95
52
600
29 90 20191
150602621
4021
70
(47)
39
43 40
5-drain hole (dia.20x88)
Drain hole (dia.25)
900
314550
270
43
95
39 47
17.5
40
40
28
17.5
320
45 5025F
G30
DI (110–140 type)
SDI: 80 type
Z view
Z
Z view
Z
300
565
101
307
6096
27
B
C
6067
154 D E
254
518
534
250
86 7
587
27 58
46
161400
B
B
F G
C
C60
2590
8979
5
165
608026
4
Air inlet
Air inlet
Air outlet
Air
inle
t
Air outlet
Air
inle
t
Space required for service
150 or more
150 or more500 or more
300 or more
SDI
SDI / DI
BC
Power supply wiring hole dia.38 knockout hole
DE
269282
264
56–140 typeName
56 type 80 type
90052 550
40
40
12
9639
48 54
60070
34
75
46 170
60380
200
17.5
128
118
74 38315017
.536
5
18 80
151400
55
24
95
9413
40
30 320
65
83 7
7
5595
1880
135
155
613
605
7058
174
581
178 178 178
518
360
655
327
60
68
534
121
534
85
B
C
9555
12 64
C
B
C
Piping drawing port
Refrigerant pipe connecting port (Gas side)
Refrigerant pipe connecting port (Liquid side)
Refrigerant pipe connecting port (Gas side)
Knockout for lower piping
Refrigerant pipe connecting port (Liquid side)
Refrigerant pipe connecting port (Gas side)
Hanger (both sides)
Refrigerant pipe connecting port (Liquid side)
Mounting bolt hole(dia.12x17 U-shape cut-out)
Mounting bolt hole(dia.12x17 long hole)
8-dia.6 hole (for fixing outdoor unit)
Charging port
Mounting bolt hole(2-dia.12x17 U-shape cut-out)
Mounting bolt hole(2-dia.12x17 long hole)
Drain hole dia.25
(Anc
hor
bolt
long
hol
e pi
tch)
(Anc
hor b
olt
long
hol
e pi
tch)
(dia
.6 h
ole
pitc
h)
B leg part
b leg part
a leg part
A leg part
B leg part
A leg part
Air outlet
Air inlet Drain hole (dia.25)
SDI DI56 ~ 80 type 110 ~ 140 type
Drain hole (dia.20x88)
Knock out(for drain)
Knockout(for drain)
Knockout for lower piping
: SDI 80 type
Air
inle
t
2-dia.11x14 long hole (for dia.8–10 anchor bolt)
2-dia.11x14 U-shape cut-out (for dia.8–10 anchor bolt)
2-dia.20x88 drain long hole
2-dia.6 hole
Detailed A leg part
Detailed A leg part
Detailed B leg part
Detailed b leg part
Detailed a leg part
Detailed B leg part
Fan guard
2-dia.6 hole
60 30
20
30
54
600
108 125
9038
54
R5.5
R15
14769.5 2155
0
483
320
306
290
635
449
365
17.5
17.5
137
93
52
8 500
483108
257
32
2522
71780
38
54
R5.5
R15
11
145
342
157 79
21
14331
54
36 (43)
95
52
600
29 90 20191
150602621
4021
70
(47)
39
43 40
5-drain hole (dia.20x88)
Drain hole (dia.25)
900
314550
270
43
95
39 47
17.5
40
40
28
17.5
320
45 5025F
G30
DI (110–140 type)
SDI: 80 type
Z view
Z
Z view
Z
300
565
101
307
6096
27
B
C
6067
154 D E
254
518
534
250
86 7
587
27 58
46
161400
B
B
F G
C
C60
2590
8979
5
165
608026
4
Air inlet
Air inlet
Air outlet
Air
inle
t
Air outlet
Air
inle
tSpace required for service
150 or more
150 or more500 or more
300 or more
SDI
SDI / DI
BC
Power supply wiring hole dia.38 knockout hole
DE
269282
264
56–140 typeName
56 type 80 type
90052 550
40
40
12
9639
48 54
60070
34
75
46 170
60380
200
17.5
128
118
74 38315017
.536
5
18 80
151400
55
24
95
9413
40
30 320
65
83 7
7
5595
1880
135
155
613
605
7058
174
581
178 178 178
518
360
655
327
60
68
534
121
534
85
B
C
9555
12 64
C
B
C
Piping drawing port
Refrigerant pipe connecting port (Gas side)
Refrigerant pipe connecting port (Liquid side)
Refrigerant pipe connecting port (Gas side)
Knockout for lower piping
Refrigerant pipe connecting port (Liquid side)
Refrigerant pipe connecting port (Gas side)
Hanger (both sides)
Refrigerant pipe connecting port (Liquid side)
Mounting bolt hole(dia.12x17 U-shape cut-out)
Mounting bolt hole(dia.12x17 long hole)
8-dia.6 hole (for fixing outdoor unit)
Charging port
Mounting bolt hole(2-dia.12x17 U-shape cut-out)
Mounting bolt hole(2-dia.12x17 long hole)
Drain hole dia.25
(Anc
hor
bolt
long
hol
e pi
tch)
(Anc
hor b
olt
long
hol
e pi
tch)
(dia
.6 h
ole
pitc
h)
B leg part
b leg part
a leg part
A leg part
B leg part
A leg part
Air outlet
Air inlet Drain hole (dia.25)
SDI DI56 ~ 80 type 110 ~ 140 type
Drain hole (dia.20x88)
Knock out(for drain)
Knockout(for drain)
Knockout for lower piping
: SDI 80 type
Air
inle
t
2-dia.11x14 long hole (for dia.8–10 anchor bolt)
2-dia.11x14 U-shape cut-out (for dia.8–10 anchor bolt)
2-dia.20x88 drain long hole
2-dia.6 hole
Detailed A leg part
Detailed A leg part
Detailed B leg part
Detailed b leg part
Detailed a leg part
Detailed B leg part
Fan guard
2-dia.6 hole
60 30
20
30
54
600
108 125
9038
54
R5.5
R15
14769.5 2155
0
483
320
306
290
635
449
365
17.5
17.5
137
93
52
8 500
483108
257
32
2522
71780
38
54
R5.5
R15
11
145
342
157 79
21
14331
54
36 (43)
95
52
600
29 90 20191
150602621
4021
70
(47)
39
43 40
5-drain hole (dia.20x88)
Drain hole (dia.25)
900
314550
270
43
95
39 47
17.5
40
40
28
17.5
320
45 5025F
G30
DI (110–140 type)
SDI: 80 type
Z view
Z
Z view
Z
300
565
101
307
6096
27
B
C
6067
154 D E
254
518
534
250
86 7
587
27 58
46
161400
B
B
F G
C
C60
2590
8979
5
165
608026
4
Air inlet
Air inlet
Air outlet
Air
inle
t
Air outlet
Air
inle
t
Space required for service
150 or more
150 or more500 or more
300 or more
SDI
SDI / DI
BC
Power supply wiring hole dia.38 knockout hole
DE
269282
264
56–140 typeName
56 type 80 type
90052 550
40
40
12
9639
48 54
60070
34
75
46 170
60380
200
17.5
128
118
74 38315017
.536
5
18 80
151400
55
24
95
9413
40
30 320
65
83 7
7
5595
1880
135
155
613
605
7058
174
581
178 178 178
518
360
655
327
60
68
534
121
534
85
B
C
9555
12 64
C
B
C
Piping drawing port
INVERTER AIR-CONDITIONING • OUTDOOR UNITS
24
AHIC is committed to continuously
improving its product to ensure
the highest quality and reliability
standards, and to meet local
regulations and market requirements.
All features and specifications are
subject to change without prior notice.
Product specifications in this brochure
are only indicative and are subject to
change. They are not intended to be
used in place of the engineering or
installation data books.
All images provided in this catalogue
are used for illustration purposes only.
Equipment rates in accordance with
MEPS 3823.2-2013 E&OE
Cooling and heating capacities
mentioned for the products are
nominal capacities at standard
operation conditions
Part number: 1013-032018
Date: March 2018
Sales and Service 13 COOL (13 2665)Tenancy 3-4, 15 Corporate Drive,Heatherton VIC 3202ABN 37 606 792 456AU22499
toshiba-aircon.com.au
MEPSCOMPLIANT
MINIMUM ENERGY
PERFORMANCE STANDARDS
MEPSCOMPLIANT