16
JM AEROFOIL Fan Code: 140JM/40/8/6/... 1400 mm 720 rev/min 6 Blades 50 Hz BS 5750 Pt 1 EN 29001 ISO 9001 04/03/99 SK11841 Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only Performance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances. 0 5 10 15 20 25 30 35 0 50 100 150 200 250 300 350 400 0 20000 40000 60000 80000 100000 120000 0 10000 20000 30000 40000 50000 60000 70000 0 5 10 15 20 25 30 35 40 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 0 5 10 15 20 25 30 35 0 2 4 6 8 10 12 8º 16º 24º 32º 8º 16º 24º 32º 95 94 97 97 97 98 102 100 99 97 97 102 ISO 5801 Type C+2D V Sound Data BS848 Part 2 1985: Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area. Inlet Levels Outlet Levels Pitch Angle Octave Band Centre Frequency (Hz) Pitch Angle Octave Band Centre Frequency (Hz) Pitch Angle 63 125 250 500 1k 2k 4k 8k Pitch Angle 63 125 250 500 1k 2k 4k 8k 8 –19 –17 –13 –11 –8 –11 –3 –6 –8 –6 –11 –6 –17 –13 –27 –25 8 –15 –13 –11 –9 –7 –10 –3 –5 –7 –6 –9 –5 –16 –11 –26 –24 16 –15 –9 –10 –6 –7 –8 –3 –9 –9 –10 –14 –8 –20 –13 –23 –21 16 –12 –6 –8 –4 –7 –8 –3 –9 –9 –10 –14 –7 –18 –12 –22 –21 24 – 36 24 – 36 –9 –7 –5 –5 –7 –7 –7 –8 –11 –12 –14 –14 –16 –15 –17 –17 –6 –4 –4 –4 –7 –6 –6 –6 –10 –12 –13 –13 –14 –13 –16 –16

Upload: others

Post on 02-Dec-2021

11 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: JM AEROFOIL - VENT-TECH

JM AEROFOILFan Code: 140JM/40/8/6/...1400 mm 720 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11841

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 30 350

50

100

150

200

250

300

350

4000 20000 40000 60000 80000 100000 120000

0 10000 20000 30000 40000 50000 60000 70000

0

5

10

15

20

25

30

35

40

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

0 5 10 15 20 25 30 350

2

4

6

8

10

12

16º

24º

32º

8º16º

24º

32º

95

94

97

97

97

98

102

100

99

97

97

102

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8–19–17

–13–11

–8–11

–3–6

–8–6

–11–6

–17–13

–27–25

8–15–13

–11–9

–7–10

–3–5

–7–6

–9–5

–16–11

–26–24

16–15

–9–10

–6–7–8

–3–9

–9–10

–14–8

–20–13

–23–21

16–12

–6–8–4

–7–8

–3–9

–9–10

–14–7

–18–12

–22–21

24 – 36 24 – 36–9–7

–5–5

–7–7

–7–8

–11–12

–14–14

–16–15

–17–17

–6–4

–4–4

–7–6

–6–6

–10–12

–13–13

–14–13

–16–16

Page 2: JM AEROFOIL - VENT-TECH

JM AEROFOILFan Code: 140JM/40/8/9/...1400 mm 720 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11842

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 30 35 400

100

200

300

400

5000 20000 40000 60000 80000 100000 120000

0 10000 20000 30000 40000 50000 60000 70000 80000

0

10

20

30

40

50

0.0

0.5

1.0

1.5

2.0

0 5 10 15 20 25 30 35 4002468

10121416

16º

24º

32º

8º16º

24º

32º

96

93

94

95

94

95

98

97

96

97

98

99

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8–17–18

–13–13

–8–11

–3–7

–7–7

–11–4

–19–12

–27–24

8–14–15

–11–10

–8–11

–2–5

–6–5

–10–3

–19–12

–26–23

16–8

–12–10–10

–9–10

–6–8

–8–8

–9–5

–14–12

–18–20

16–4–8

–8–7

–8–8

–6–8

–7–7

–8–4

–12–12

–17–18

24 – 36 24 – 36–7–7

–7–7

–8–7

–7–7

–9–9

–13–12

–15–15

–14–17

–3–3

–3–3

–6–5

–7–6

–9–8

–12–11

–13–13

–13–16

Page 3: JM AEROFOIL - VENT-TECH

JM AEROFOILFan Code: 140JM/50/8/12/...1400 mm 720 rev/min 12 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11844

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 30 35 400

100

200

300

400

500

6000 20000 40000 60000 80000 100000 120000

0 10000 20000 30000 40000 50000 60000 70000 80000

0

10

20

30

40

50

60

0.0

0.5

1.0

1.5

2.0

0 5 10 15 20 25 30 35 4002468

1012141618

16º

24º

32º

8º16º

24º

32º

96

94

97

96

96

96

98

98

98

98

100

101

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8–16–18

–8–12

–8–10

–4–5

–8–6

–14–7

–23–14

–30–24

8–14–15

–5–9

–8–10

–3–4

–7–5

–12–5

–21–12

–28–22

16–16–11

–12–5

–5–11

–4–8

–9–8

–17–7

–25–14

–28–21

16–13

–8–9–2

–4–10

–4–8

–9–8

–16–6

–22–11

–26–18

24 – 36–6–7

–6–5

–10–9

–8–8

–10–10

–14–12

–17–17

–16–20

–3–3

–2–1

–8–7

–7–7

–9–9

–14–11

–15–16

–15–19

24 – 36

Page 4: JM AEROFOIL - VENT-TECH

JM AEROFOILFan Code: 140JM/40/6/6/...1400 mm 960 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11845

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 30 35 40 450

100

200

300

400

500

600

7000 20000 40000 60000 80000 100000 120000 140000

0 20000 40000 60000 80000

0

10

20

30

40

50

60

70

0.0

0.5

1.0

1.5

2.0

2.5

0 5 10 15 20 25 30 35 40 450

5

10

15

20

25

16º

24º

32º

8º16º

24º

32º

103

101

104

104

105

106

110

108

106

104

103

108

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8–15–12

–14–11

–12–12

–4–8

–6–6

–11–7

–13–8

–26–23

8–12

–9–11–9

–11–11

–3–7

–5–5

–9–6

–12–7

–24–22

16–12

–6–10

–7–11–9

–4–10

–7–12

–13–10

–18–10

–23–22

16–10

–2–9–5

–10–9

–3–10

–7–12

–13–10

–16–9

–21–21

24 – 36 24 – 36–7–5

–5–7

–9–9

–8–8

–10–11

–14–14

–16–16

–18–18

–4–1

–4–5

–8–7

–7–7

–9–11

–12–13

–14–14

–16–17

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Page 5: JM AEROFOIL - VENT-TECH

JM AEROFOILFan Code: 140JM/40/6/9/...1400 mm 960 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11846

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 500

100

200

300

400

500

600

700

800

9000 50000 100000 150000

0 20000 40000 60000 80000 100000

0

20

40

60

80

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

0 10 20 30 40 5005

101520253035

16º

24º

32º

8º16º

24º

32º

102

100

101

102

101

102

105

104

103

103

105

106

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8–19–18

–15–13

–12–14

–4–9

–5–7

–11–6

–14–7

–26–22

8–15–15

–12–10

–10–13

–2–7

–4–5

–9–4

–14–6

–25–20

16–7

–12–9–9

–11–11

–7–10

–8–9

–10–6

–11–7

–18–20

16–4–8

–6–6

–10–10

–7–9

–7–8

–9–5

–9–7

–17–17

24 – 36 24 – 36–6–7

–6–6

–10–9

–8–8

–9–9

–12–11

–15–14

–15–18

–2–3

–3–3

–8–6

–7–7

–8–8

–11–11

–14–12

–14–16

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Page 6: JM AEROFOIL - VENT-TECH

JM AEROFOILFan Code: 140JM/50/6/9/...1400 mm 960 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11847

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 500

100

200

300

400

500

600

700

800

9000 50000 100000 150000

0 20000 40000 60000 80000 100000

0

20

40

60

80

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

0 10 20 30 40 5005

101520253035

16º

24º

32º

8º16º

24º

32º

104

103

107

106

106

107

109

109

109

105

106

110

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8–15–12

–10–11

–9–11

–4–6

–6–6

–12–8

–15–11

–27–24

8–12

–9–8–8

–8–10

–3–5

–5–5

–11–7

–15–9

–25–22

16–12

–7–12

–8–9–8

–3–9

–8–9

–13–9

–18–11

–24–20

16–9–5

–9–5

–7–6

–3–7

–6–8

–12–7

–16–10

–23–19

24 – 36 24 – 36–6–5

–5–5

–9–9

–9–10

–11–13

–14–14

–16–16

–18–19

–4–3

–2–2

–8–7

–7–8

–10–11

–13–13

–15–14

–17–18

Page 7: JM AEROFOIL - VENT-TECH

JM AEROFOILFan Code: 140JM/50/6/12/...1400 mm 960 rev/min 12 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11848

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 500

200

400

600

800

10000 50000 100000 150000

0 20000 40000 60000 80000 100000

0

20

40

60

80

100

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

0 10 20 30 40 5005

10152025303540

16º

24º

32º

8º16º

24º

32º

102

101

103

103

102

102

104

104

105

104

106

107

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8–17–19

–11–14

–9–12

–4–6

–6–5

–13–7

–18–9

–29–22

8–15–16

–9–13

–7–10

–3–6

–5–4

–10–5

–16–7

–27–20

16–16–10

–15–11

–9–7

–3–9

–7–8

–14–8

–21–9

–27–20

16–12

–7–13

–9–7–4

–3–9

–6–8

–13–6

–19–6

–26–17

24 – 36 24 – 36–5–7

–8–9

–8–7

–9–8

–9–9

–13–11

–16–14

–17–20

–2–2

–5–5

–6–4

–8–7

–8–8

–13–11

–15–13

–16–19

Page 8: JM AEROFOIL - VENT-TECH

JM AEROFOILFan Code: 140JM/50/6/12/...1400 mm 960 rev/min 12 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11848

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 500

200

400

600

800

10000 50000 100000 150000

0 20000 40000 60000 80000 100000

0

20

40

60

80

100

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

0 10 20 30 40 5005

10152025303540

16º

24º

32º

8º16º

24º

32º

102

101

103

103

102

102

104

104

105

104

106

107

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8–17–19

–11–14

–9–12

–4–6

–6–5

–13–7

–18–9

–29–22

8–15–16

–9–13

–7–10

–3–6

–5–4

–10–5

–16–7

–27–20

16–16–10

–15–11

–9–7

–3–9

–7–8

–14–8

–21–9

–27–20

16–12

–7–13

–9–7–4

–3–9

–6–8

–13–6

–19–6

–26–17

24 – 36 24 – 36–5–7

–8–9

–8–7

–9–8

–9–9

–13–11

–16–14

–17–20

–2–2

–5–5

–6–4

–8–7

–8–8

–13–11

–15–13

–16–19

Page 9: JM AEROFOIL - VENT-TECH

JM AEROFOILFan Code: 140JM/50/4/9/...1400 mm 1470 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11849

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 50 60 700

500

1000

1500

20000 50000 100000 150000 200000

0 20000 40000 60000 80000 100000 120000 140000

0

50

100

150

200

0

1

2

3

4

5

6

7

8

0 10 20 30 40 50 60 700

20

40

60

80

100

120

16º

24º

32º

8º16º

24º

32º

115

113

116

116

116

117

119

119

119

115

116

119

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8–14–10

–16–15

–10–10

–7–10

–4–5

–8–7

–12–8

–20–15

8–11–7

–14–11

–8–8

–6–9

–3–5

–7–6

–12–7

–18–13

16–11–6

–14–10

–10–7

–5–10

–5–9

–9–10

–14–9

–21–15

16–8–3

–13–7

–8–4

–5–8

–4–9

–8–8

–13–8

–20–14

24 – 36 24 – 36–6–5

–9–8

–6–6

–9–10

–10–11

–13–14

–15–15

–17–18

–3–2

–6–7

–4–3

–8–9

–9–10

–12–13

–14–14

–16–16

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Page 10: JM AEROFOIL - VENT-TECH

JM AEROFOILFan Code: 140JM/50/4/12/...1400 mm 1470 rev/min 12 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11850

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 50 60 70 800

500

1000

1500

2000

25000 50000 100000 150000 200000 250000

0 20000 40000 60000 80000 100000 120000 140000 160000

0

50

100

150

200

250

0

2

4

6

8

10

0 10 20 30 40 50 60 70 800

20406080

100120140

16º

24º

32º

8º16º

24º

32º

112

110

112

112

112

112

114

114

114

114

116

116

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8–20–21

–16–18

–8–12

–9–10

–3–5

–8–6

–14–7

–22–14

8–18–19

–14–17

–6–10

–8–9

–3–3

–5–4

–13–5

–21–12

16–18–12

–16–11

–12–6

–5–11

–4–8

–9–8

–16–7

–25–14

16–15

–8–14

–9–11–3

–4–10

–3–8

–8–7

–14–4

–23–11

24 – 36 24 – 36–7–8

–6–8

–7–6

–10–10

–9–9

–11–10

–15–12

–17–17

–4–5

–3–4

–5–3

–9–9

–8–8

–11–10

–14–11

–17–16

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Page 11: JM AEROFOIL - VENT-TECH

JM AEROFOILFan Code: 140JM/40/12/6/...1400 mm 480 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11852

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 250

20

40

60

80

100

120

140

160

1800 20000 40000 60000 80000

0 10000 20000 30000 40000 50000

0

5

10

15

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0 5 10 15 20 250.00.51.01.52.02.53.03.5

16º

24º

32º

8º16º

24º

32º

86

85

88

88

87

89

93

91

90

88

88

93

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8–13–10

–11–12

–3–8

–6–5

–11–7

–13–8

–26–23

–32–30

8–11–8

–9–10

–3–7

–5–5

–10–7

–11–7

–25–22

–30–29

16–10

–5–10

–8–3–8

–7–11

–13–9

–17–8

–22–20

–26–24

16–9–3

–9–6

–2–8

–7–11

–12–8

–17–8

–20–19

–25–23

24 – 36 24 – 36–5–5

–8–7

–7–7

–8–10

–13–13

–15–14

–17–16

–19–18

–3–3

–7–6

–6–5

–7–8

–12–13

–14–13

–15–14

–17–16

Page 12: JM AEROFOIL - VENT-TECH

JM AEROFOILFan Code: 140JM/40/12/9/...1400 mm 480 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11853

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 250

50

100

150

200

2500 20000 40000 60000 80000

0 10000 20000 30000 40000 50000

0

5

10

15

20

25

0.0

0.2

0.4

0.6

0.8

1.0

0 5 10 15 20 250.00.51.01.52.02.53.03.54.04.5

16º

24º

32º

8º16º

24º

32º

87

84

85

86

85

86

89

88

87

88

90

91

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8–14–13

–11–13

–4–8

–5–6

–10–5

–14–7

–25–22

–31–28

8–11–10

–9–11

–3–8

–3–5

–9–4

–12–5

–25–21

–30–27

16–8–9

–10–11

–6–9

–7–8

–9–5

–10–7

–17–19

–20–24

16–5–5

–8–9

–5–8

–7–8

–7–4

–10–6

–15–19

–19–22

24 – 36 24 – 36–5–5

–9–8

–7–7

–8–8

–11–10

–14–14

–14–17

–15–19

–1–1

–6–5

–5–4

–7–7

–11–9

–13–13

–13–15

–14–17

Page 13: JM AEROFOIL - VENT-TECH

JM AEROFOILFan Code: 140JM/40/10/6/...1400 mm 575 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11854

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 300

50

100

150

200

2500 20000 40000 60000 80000 100000

0 10000 20000 30000 40000 50000 60000

0

5

10

15

20

25

0.0

0.2

0.4

0.6

0.8

1.0

0 5 10 15 20 25 300

1

2

3

4

5

6

16º

24º

32º

8º16º

24º

32º

90

89

92

92

92

92

96

95

94

92

92

97

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8–17–15

–12–10

–5–9

–4–5

–9–7

–11–7

–22–19

–29–28

8–14–12

–10–8

–4–8

–4–4

–9–6

–10–5

–22–18

–28–27

16–13

–8–10

–6–4–8

–4–10

–11–9

–16–8

–21–17

–24–23

16–11–5

–9–4

–4–7

–4–10

–11–9

–16–7

–19–16

–23–22

24 – 36–8–7

–5–5

–7–7

–8–8

–12–12

–15–14

–16–16

–18–17

–6–4

–4–4

–6–5

–6–7

–11–12

–13–13

–15–14

–16–16

24 – 36 24 – 3624 – 36

Page 14: JM AEROFOIL - VENT-TECH

JM AEROFOILFan Code: 140JM/40/10/9/...1400 mm 575 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11855

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 300

50

100

150

200

250

300

3500 20000 40000 60000 80000 100000

0 10000 20000 30000 40000 50000 60000

0

5

10

15

20

25

30

35

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

0 5 10 15 20 25 30012345678

16º

24º

32º

8º16º

24º

32º

91

88

89

90

89

89

93

92

91

92

94

94

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8–15–14

–12–15

–6–9

–4–6

–9–6

–12–5

–23–18

–28–26

8–12–11

–10–12

–5–9

–2–5

–8–5

–11–3

–24–18

–28–25

16–8–9

–12–13

–6–9

–6–8

–9–7

–9–5

–16–17

–19–22

16–5–6

–10–10

–6–7

–6–8

–7–5

–8–5

–14–17

–18–20

24 – 36 24 – 36–6–6

–10–9

–7–6

–7–8

–10–10

–14–13

–14–16

–14–17

–1–1

–7–6

–5–4

–7–7

–9–8

–13–12

–13–14

–13–16

Page 15: JM AEROFOIL - VENT-TECH

JM AEROFOILFan Code: 140JM/50/10/12/...1400 mm 575 rev/min 12 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11857

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 300

50

100

150

200

250

300

3500 20000 40000 60000 80000 100000

0 10000 20000 30000 40000 50000 60000

0

5

10

15

20

25

30

35

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

0 5 10 15 20 25 300123456789

16º

24º

32º

8º16º

24º

32º

91

89

92

91

90

90

92

92

92

93

95

96

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8–13–15

–8–12

–5–8

–5–4

–11–7

–16–8

–27–20

–32–26

8–11–13

–5–10

–5–8

–4–4

–10–6

–14–6

–25–18

–30–24

16–16–12

–10–6

–3–9

–5–7

–12–8

–19–8

–26–18

–29–22

16–12

–8–7–3

–2–9

–5–8

–11–7

–19–6

–24–15

–28–19

24 – 36–7–8

–6–5

–8–8

–7–8

–11–10

–15–12

–16–18

–16–20

–4–4

–20

–7–6

–6–7

–10–9

–14–12

–14–17

–15–19

24 – 36

Page 16: JM AEROFOIL - VENT-TECH

JM AEROFOILFan Code: 160JM/40/8/6/...1600 mm 720 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11858

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 500

50

100

150

200

250

300

350

400

4500 50000 100000 150000

0 20000 40000 60000 80000 100000

0

10

20

30

40

0.0

0.5

1.0

1.5

0 10 20 30 40 5002468

1012141618

16º

24º

32º

8º16º

24º

32º

97

99

104

99

99

102

101

101

104

100

102

105

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8–19–16

–12–13

–5–11

–4–6

–9–5

–14–8

–18–11

–26–23

8–16–13

–9–11

–4–10

–4–5

–8–4

–13–6

–17–10

–24–22

16–15–10

–13–9

–10–9

–4–7

–6–8

–10–8

–13–10

–17–15

16–13

–7–12

–7–9–9

–4–7

–6–7

–10–8

–12–9

–16–14

24 – 3224 – 32 24 – 3224 – 32–13

–9–7–7

–6–8

–6–7

–10–8

–15–11

–17–12

–19–13

–10–6

–6–6

–6–7

–5–6

–9–8

–13–10

–15–10

–18–12

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.