Page 1: JM Aerofoil 50 Hz Technical

JM Aerofoil 50 Hz

A Fläkt Woods Company

Page 2: JM Aerofoil 50 Hz Technical

JM AEROFOIL

CONTENTS

3

Page

JM Aerofoil - Introduction 4 - 5

Specification 6 - 7

Quality Systems 8

How To Specify 9

Guide To Fan Selection - Total Pressure 10 - 11- Static Pressure 12 - 13

Motor Frame Size Schedules - Single Phase - Single Speed 15 - 17- Three Phase - Single Speed 18 - 29- Three Phase - Two Speed 30 - 59

Performance Curves SK11685-SK11865

Dimensions and Weights 60 - 64

Ancillaries 65 - 66

Useful Information 67

Page 3: JM Aerofoil 50 Hz Technical

JM AEROFOIL

INTRODUCTION

4

Air movement technology is a world of spe-

cialised knowledge and one in which Fläkt

Woods are not just the specialists but one of the

acknowledged leaders. Fläkt Woods extensive

knowledge of designs and applications extends

back over 90 years of experience as one of the

world’s largest manufacturers of fans and air

moving equipment.

Based in Europe, Fläkt Woods have extensive

laboratories that constantly develop new con-

cepts and product ranges, enabling the group to

maintain its market leadership. Fläkt Woods

have subsidiary companies in 31countries world

wide plus, a network of fully trained local staff in

70 different countries with intimate knowledge of

local needs.

In fact Fläkt Woods products are marketed andinstalled in over 100 countries, with applicationsranging from the world’s largest engineeringprojects to the smallest cabinet cooling system.

Whatever the product size or cost it is FläktWoods policy to provide the highest quality atcompetitive prices, all backed by dedicated staff,fully trained to provide customer satisfaction.

Fläkt and Woods Air Movement Limited are BSEN ISO 9001:94 Registered Companies.

In line with the Company’s strict adherence tothe highest quality assurance standards, regularquality audits occur ensuring that the JM Aerofoilconsistently meet the catalogue specifications,now independently endorsed by the AirMovement and Control Association International(AMCA).

Page 4: JM Aerofoil 50 Hz Technical

JM AEROFOIL

INTRODUCTION

5

All Aluminium Precision Die-Cast ImpellerA unique high efficiency aerofoil section bladewithin a purposely smoothed hub and clamp-plate for adjustable pitch angle flexibility. TheWoods impellers are all precision die-cast tooffer thin aerofoil sections for low generation ofnoise levels. Every cast aluminium componentis X-rayed using Real Time Radiography inspec-tion prior to assembly. This feature can provideevidence of casting quality against product liabil-ity legislation if specified.

Fan MotorsAll Woods JM range of fans incorporate an elec-trical power drive specifically designed to opti-mise fan performance, and minimise theobstruction to airflow.Totally enclosed, pad mounted design to desig-nation IP55, Class F insulation as standard.Directly coupled to the fan impeller to minimisedrive losses. Overheat protection is included onsingle phase machines and available on others.

TestingPerformance data has been obtained in accor-dance with the internationally recognised stan-dard - ISO5801:1997 installation category D(AMCA approved) for aerodynamic performanceand BS 848 Part 2 (1985) for acoustic perform-ance.

FixingsAll fixings are protected with an organicallybased zinc coating to provide excellent corrosionresistance.

ArmsMounting arms are specially designed to offerminimal resistance to airflow. These arms arecarefully spaced away from the impeller to min-imise noise generation.The arms also improve the cooling of the motor,hence increasing motor performance and life. Allarms are hot dipped galvanised after manufac-ture for maximum resistance to corrosion.

CasingsAvailable in either a long cased form completewith an externally mounted pre-wired electricalterminal box, or short cased for duct or plateinstallation. Casings are spun from sheet steelwith integral pre-drilled flanges, fully weldedseams and hot-dipped galvanised after manu-facture for excellent durability.

Page 5: JM Aerofoil 50 Hz Technical

JM AEROFOIL

SPECIFICATION

6

MotorsConstructed from aluminium up to frame sizeD160, cast iron above as standard with special"T" slot or pad mounted fixings.Suitable for horizontal through to vertical shaftoperation.Supplied IP55, with removable drain plugs.Bearings lubricated with wide temperature rangegrease, sealed for life.Continuous operating range -40° C to +50° C,minimum starting temperature -20°C(for otheroperating temperatures please enquire).Insulation class F as standard.2 speed operation by Delta/Star recon- nection available on most three phase motor upto frame size F22.Integral pre-wired capacitor on most singlephase fans.Ratings comply with BS5000 Part 99 and IEC 34-1.

Two speed motors availablePole Change (PC) or DahlanderTwo speeds can be obtained by reconnecting asingle winding via six winding terminals to givetwo separate pole numbers.Dual WoundThis type of motor has two separate individualwindings of the requisite poles to give thespeeds required.

Electrical Supply220-240 V 50 Hz single phase (1φ)380-420 V 50 Hz three phase (3φ)(60 Hz variants and other voltages are availableon request).

Speed control can be provided by Fläkt Woodsrange of electronic and auto-transformer typespeed controllers. Speed control details arebased on the adoption of the more usual andtechnically superior three-wire circuit.Refer to Colchester if two wire control isrequired. The single phase controller rating maybe less than the full load current, as only the "U"phase voltage is varied. Many of the regulatable, three phase motorsmay be offered for 2 speed applications byDelta/Star reconnection.

ImpellersJM Aerofoil impellers have a unique aerodynamicsection blade to optimise the efficiency of per-formance and minimise the generation of noise.The thin sections obtained by precision die castmanufacturing techniques help promote theseparticular features whilst also allowing a lighterweight assembly to be produced.Precision die cast aluminium hub and clamp-plate, with equally spaced, fully adjustable, highpressure die cast aerofoil section blades.All rotating aluminium components are X-rayexamined prior to machining to assure quality.Balanced to BS6861 Part 1 1987 (ISO 1940-1986) Grade G6.3. Corrosion resistant and suit-able for continuous outside use from -40°C to+50°C, (for other operating temperatures pleaseenquire).

Non-overloadingJM Aerofoil fans have a non-overloading charac-teristic; the peak power input occurs within therange of normal operating pressures and isalways exceeded by the motor rating.

AncillariesMotor and Impeller side guards to comply withBS848 Pt 5., and draft ISO standard.Choice of auto-transformer or electronic speedcontrollers.2 speed switch for Delta/Star reconnection,Silencers.Mounting Feet for both horizontal or verticaloperation.Matching Flanges, Flexible Connectors.Air Operated Dampers for horizontal or verticalup operation. Bellmouth inlets. Vibration Isolators.Control gear complete with BMS contacts avail-able on request.

FinishFan casings, motor mounting arms, mountingfeet, matching flanges and guards are all hotdipped galvanised after manufacture, (in accor-dance with BS EN ISO 1461:1999).Motors, aluminium self finish,or painted to motormanufacturers specification.

(∆/ )

Y

(∆/ )

Y

(∆/ )

Y

Page 6: JM Aerofoil 50 Hz Technical

JM AEROFOIL

SPECIFICATION

7

Reversal of AirflowFläkt Woods has developed the JM Aerofoil togive the optimum aerodynamic and acoustic per-formance. To optimise the performance WoodsAir Movement used the latest design software toestablish the blade shape and in particular theaerodynamic blade sections. The results of lab-oratory testing demonstrated world class aero-dynamic and acoustic performance that is AMCAapproved.

As part of our commitment to fan engineeringand total quality Fläkt Woods have establishedthe operational limits of the impellers in all cir-cumstances. Under laboratory conditions FläktWoods have tested JM impellers when run for-wards, and in reverse. By measuring the stress-es on the impellers under these conditions, andrelating these stresses to the properties of thealloys used for impeller construction, it is possi-ble to determine the maximum speed of theimpeller for reliable life long operation.

A further factor that must be considered inassessing the life of the impeller is the quality ofthe casting.

Extensive testing of the alloys we use has estab-lished relationships between life, operationalstresses, and casting quality. Therefore to fur-ther ensure reliable operation of our impellers allalloy impeller castings are assessed using x-rayagainst rigorous acceptance criteria.

Since the stresses experienced in the reversemode are generally higher than those in forwardoperation some impeller configurations are notsuitable for applications that require continuousor regular reverse operation. Where this is thecase we have highlighted the fact on each rele-vant performance chart within this catalogue. Ifthese fans are required to be operated inreverse in other than cases of emergency, theneach instance should be referred to the UKmanufacturing plant for qualification or re-selec-tion of impeller type.

All other impeller configurations can be safelyoperated in reverse. Reversal is obtained byinterchanging electrical connections.

Forms of RunningThe direction of airflow through the fan and thefan mounting position are defined as the "Formof running".On each chart is shown the standard Form(s) ofrunning for that particular fan, when mountedhorizontally. For vertical operation add suffix "U"for airflow up, or suffix "D" for airflow down.The standard Form of running offered will beForm B. When an alternative is available: seechart information, please request when the fanis ordered. Form of running is especially rele-vant when weatherproofed motors are required.Arrows indicating correct rotation and directionof airflow are incorporated in the duct name-plate.

Test MethodsTestingThe air and sound performance data has beenmeasured by the latest version of British andInternational Standards:-ISO 5801:1997 method for testing air perform-ance (dual numbered BS848 Pt1 1997).BS848 Pt 2 1985, method of noise testing.It is essential, when comparing fan performanc-es, that the same installation category and teststandards are used at all times.

Acoustic DataThe sound levels quoted are based on testscarried out under the Fläkt Woods certified lab-oratory conditions. Using the spectrum correc-tions stated on each performance chart, anunweighted sound power spectrum can beobtained for the fan.

Motor RatingsThe motor ratings, starting, full load currentsand speeds refer to the maximum output ofthe motor. When the impeller does not requirethe full output, the power and current will beless than the maximum quoted.

Form A Form B Form AD

Form BDForm BUForm AU

Page 7: JM Aerofoil 50 Hz Technical

JM AEROFOIL

QUALITY SYSTEMS

8

AMCA CertificationFläkt Woods certifies that the JM Aerofoil shownherein is licensed to bear the AMCA Seal. Theratings shown are based on tests and proce-dures performed in accordance with AMCAPublication 211 and comply with the require-ments of the AMCA Certified Ratings Program.

Quality SystemsFläkt Woods is committed to Quality Assurance.Registration to BS EN ISO 9001.94, means thatFläkt Woods design is quality assured as well asthe manufacture.

Our commitment to Quality Assurance doesn'tstop with the hardware. The performance datacomes from standard tests carried out in FläktWoods own laboratory which is British Standardand AMCA accredited. Those fans which areAMCA licensed for aerodynamic performanceare identified by the AMCA Seal on the appropri-ate characteristic curve(s).

A JM Aerofoil fan can be bought with the confi-dence as with all Fläkt Woods products, that itwill achieve the published performance dataand match the assured quality. All JM Aerofoilfans are fitted with IP55 motors as standard, andcome with a 2 year ex works warranty.

All fans as detailed in this publication can besupplied for a one off emergency operation attemperatures up to 200°C for 2 hours (H.T.Category 200/2). This facility is independentlycertified by the Loss Prevention CertificationBoard (LPCB), Certificate number 386a Issue 2.Certain fans can be supplied for a one off emer-gency operation at temperatures up to 400°C for2 hours (H.T. Category 400/2 LPCB approved)Please refer to Publication JM/HT for details.

Page 8: JM Aerofoil 50 Hz Technical

JM AEROFOIL

HOW TO SPECIFY

9

Specifying The Fan

Having chosen the fan most suitable for your indi-vidual application.Please specify as follows:-

The fan shall be manufactured by FläktWoods model type JM Aerofoil long or shortcased (L or S-type).

Motors, squirrel cage type, insulated toclass F, bearings lubricated with wide tem-perature grease, keyed shaft. To complywith BS5000 Pt 99 and IEC 34-1.Weatherproof to IP55. (Overheat protec-tion provided on most single phasemotors).

Impellers, precision die cast aluminiumhub and clamp-plate, with equally spaced,fully adjustable precision die cast Aerofoilsection blades. All rotating aluminiumcomponents to be X-ray examined prior tomachining to assure quality of castings.

Casings, either a long cased form completewith an externally mounted pre-wired elec-trical terminal box, or short cased for ductor plate installation. Casings are spun fromsheet steel with integral pre-drilled flanges,fully welded seams and hot-dipped gal-vanised after manufacture for excellentdurability.

Mounting Arms, manufactured from mildsteel hot dipped galvanised after manufac-ture.

Performance shall be independantlyapproved by AMCA, and established inaccordance with ISO5801:1997 installationcategory D, method of testing air perform-ance and BS848 Pt 2 1985 method ofnoise testing.

Ancillaries as required.

Ordering The Fan

After identifying the best fan for your applicationplease order as follows:-

Fan type: JM Aerofoil Long cased (L-type),or Short Cased (S-type) Form A or Form B.

Fan Code:eg: 63JM/20/8/6/24where: 63 denotes the Fan impeller

diameter in centimetres.JM denotes Fan Type./20 denotes impeller hub diameter in centimetres./8 denotes a nominal 8 pole speed./6 denotes the number of blades./24 denotes the Pitch Angle for therequired duty.

Quantity required.

Duty required at standard air and tempera-ture e.g. 1.60 m3/s @ 50 Pa.

Motor. eg: CT5

Electrical Supply:220-240 V / 50 Hz / 1φ380-420 V / 50 Hz / 3φ

Ancillary items required.

Mounting FeetImpeller and Motor Side GuardsSilencers with or without podSpeed Controller (electronic or auto-trans-former) or 2 speed swith type MDS3.10Air Operated DampersMatching FlangesBellmouth InletsFlexible ConnectorsVibration Isolators

1.

2.

3.

4.

5.

6.

7.

1.

2.

3.

4.

5.

6.

7.

Page 9: JM Aerofoil 50 Hz Technical

There are two principle methods of expressingthe pressure requirements, namely, PF (Total)

and PSF (Static) pressure. The two types of

pressure are related:

PF = PSF + PdF PF = Fan Total pressure

PSF = Fan Static pressure

PdF = Fan Dynamic pressure

The international convention considers fan per-formance in terms of total pressure, but there isalso established practice relating to the use ofstatic pressure. For this reason Woods’ selec-tion charts are laid out on a total pressure majorscale and include a secondary grid for staticpressure. The facility to display fan performancein terms of static pressure is necessary in orderto avoid total pressure fan selections beingmade based on static pressure system require-ments.

The guide selections are made for either total orstatic pressures of 100Pa. The resulting selec-tions are quite different and highlight the conse-quences of selecting static pressure from chartsthat only display performance in terms of totalpressure.

Procedure - Total Pressure (PF)

1. Guide to Chart Numbers of Possible Selections

The charts are arranged in order of fan diameter,starting at 315 mm, up to 1600 mm diameter,and in order of fan speed for each diameter,3,5,6,9 & 12 bladed fan impellers as available.

NOTE: The chart numbers lead to a variety offan sizes, impeller configurations and speeds.The fan selected from the alternatives availablewill depend on the most critical factor for the par-ticular application - Volume Flow and Pressurerequired, Size, Power Consumption, SoundLevel or First Cost.

2. Required DutyEstablish the volume flow and total pressurerequired of an individual fan at Standard Air (1.2kg/m3).

3. Selection on Individual Fan ChartsThe data provided on each performance chart isspecifically for ducted - Type D (ducted) installa-tions for both long or short cased (S-type) fans.Providing reasonable Type D conditions aremaintained in installation of the fans, no addi-tional factors to volume flow or pressure needbe incorporated for a suitable selection to bemade.

Plot the duty on the selected fan charts to estab-lish blade angle, sound level, absorbed power,motor size and rating, for the particular arrange-ment.

Duty Point Required - @ Standard Air (1.2kg/m3). 0.55 m3/s @ 100Pa total pressure.

Volume Flow = 0.55 m3/s

Fan Total Pressure = 100 Pa

Overall inlet Sound Power Level = 72 LWIinterpolated from surrounding levels).

Pitch Angle required to achieve Duty Point= 28°

Corrections to overall Sound Power Levelfor 28° Pitch Angle. (Operating Point isBelow shaded area)

Absorbed Power @ Duty Point @ 28°Pitch Angle = 0.09 kWSuitable Motor for fixed speed application,3 phase supply, from motor schedules = BT4Motor Data:Motor Rating (kW) = 0.15Full Load (A) = 0.5Starting current (A) = 2.0

Speed Regulatable VersionsIf a speed regulatable version is required, (orDelta/Star reconnect on 3 phase versions)the duty volume flow required should be multi-plied by 1.05 prior to fan selection being made.

Frequency Hz

63 125 250 500 1K 2K 4K 8K

Sound Power Inlet 65 67 64 65 60 54 51 45 Lw

Level Outlet 67 70 65 65 60 54 52 46 Lw

JM AEROFOILGUIDE TO FAN SELECTIONSELECTION EXAMPLE - TOTAL PRESSURE

10

D

1

2

3

4

5

6

(∆/ )

Y

Page 10: JM Aerofoil 50 Hz Technical

74

70

72

3

6

5

2

D

4

1

70

73

SAMPLE

SAMPLE

JM AEROFOILFan Code:35JM/16/4/5/...355mm 1420 rev/min 5 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11689

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformanceshownis for installations typeD- Ducted inlet,Ductedoutlet.Performanceratingsdonot includetheeffectsofappurtenances.

0.0 0.20

20

40

60

80

100

120

140

1600 500 1000 1500 2000 2500 3000 3500 4000

0 500 1000 1500 2000 2500

4

6

8

10

12

14

16

0.2

0.3

0.4

0.5

0.6

0.0 0.2 0.4 0.6 0.8 1.01.0 1.20.000.020.040.060.080.100.120.140.16

16°

24°

32°

40°

8° 16°24°

32°

40°

72

76

76

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8-9

-14-7

-10-5-7

-5-3

-13-10

-20-16

-27-22

-35-31

8-6

-12-5-8

-4-7

-5-3

-13-9

-20-16

-27-20

-35-29

16-12-10

-6-6

-6-7

-5-6

-13-9

-15-12

-21-17

-27-24

16-10

-9-3-3

-6-6

-5-6

-12-9

-14-12

-21-17

-27-24

24 - 4024 - 40 24 - 4024 - 40-5-7

-6-5

-7-8

-8-7

-14-12

-18-16

-23-21

-28-27

-3-5

-5-2

-7-7

-7-7

-13-12

-17-16

-21-20

-26-26

74

73

0.4 0.6 0.8 1.0 1.20

2

0.0

0.1

70

69

71

74

76

76

75

JM AEROFOIL

Page 11: JM Aerofoil 50 Hz Technical

JM AEROFOIL

There are two principle methods of expressingthe pressure requirements, namely, PF (Total)

and PSF (Static) pressure. The two types of

pressure are related:

PF = PSF + PdF PF = Fan Total pressure

PSF = Fan Static pressure

PdF = Fan Dynamic pressure

The international convention considers fan per-formance in terms of total pressure, but there isalso established practice relating to the use ofstatic pressure. For this reason Woods’ selec-tion charts are laid out on a total pressure majorscale and include a secondary grid for staticpressure. The facility to display fan performancein terms of static pressure is necessary in orderto avoid total pressure fan selections beingmade based on static pressure system require-ments.

The guide selections are made for either total orstatic pressures of 100Pa. The resulting selec-tions are quite different and highlight the conse-quences of selecting static pressure from chartsthat only display performance in terms of totalpressure.

Procedure - Ststic Pressure (PF)

1. Guide to Chart Numbers of Possible Selections

The charts are arranged in order of fan diameter,starting at 315 mm, up to 1600 mm diameter,and in order of fan speed for each diameter,3,5,6,9 & 12 bladed fan impellers as available.

NOTE: The chart numbers lead to a variety offan sizes, impeller configurations and speeds.The fan selected from the alternatives availablewill depend on the most critical factor for the par-ticular application - Volume Flow and Pressurerequired, Size, Power Consumption, SoundLevel or First Cost.

2. Required DutyEstablish the volume flow and total pressurerequired of an individual fan at Standard Air (1.2kg/m3).

3. Selection on Individual Fan ChartsThe data provided on each performance chart isspecifically for ducted - Type D (ducted) installa-tions for both long or short cased (S-type) fans.Providing reasonable Type D conditions aremaintained in installation of the fans, no addi-tional factors to volume flow or pressure needbe incorporated for a suitable selection to bemade.

Plot the duty on the selected fan charts to estab-lish blade angle, sound level, absorbed power,motor size and rating, for the particular arrange-ment.

Duty Point Required - @ Standard Air (1.2kg/m3). 0.55 m3/s @ 100Pa static pressure.

Volume Flow = 0.55 m3/s

Fan Total Pressure = 100 Pa

Overall inlet Sound Power Level = 74 LWIinterpolated from surrounding levels).

Pitch Angle required to achieve Duty Point= 32°

Corrections to overall Sound Power Levelfor 32° Pitch Angle. (Operating Point isabove shaded area)

Absorbed Power @ Duty Point @ 32°Pitch Angle = 0.11 kWSuitable Motor for fixed speed application,3 phase supply, from motor schedules = BT4Motor Data:Motor Rating (kW) = 0.15Full Load (A) = 0.5Starting current (A) = 2.0

Speed Regulatable VersionsIf a speed regulatable version is required, (orDelta/Star reconnect on 3 phase versions)the duty volume flow required should be multi-plied by 1.05 prior to fan selection being made.

Frequency Hz

63 125 250 500 1K 2K 4K 8K

Sound Power Inlet 69 68 67 66 60 56 51 46 Lw

Level Outlet 71 69 67 67 61 57 53 48 Lw

GUIDE TO FAN SELECTIONSELECTION EXAMPLE - STATIC PRESSURE

12

D

1

2

3

4

5

6

(∆/ )

Y

Page 12: JM Aerofoil 50 Hz Technical

74

70

72

3

6

5

2

D

4

1

70

73

SAMPLE

SAMPLE

JM AEROFOILFan Code:35JM/16/4/5/...355mm 1420 rev/min 5 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11689

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformanceshownis for installations typeD- Ducted inlet,Ductedoutlet.Performanceratingsdonot includetheeffectsofappurtenances.

0.0 0.20

20

40

60

80

100

120

140

1600 500 1000 1500 2000 2500 3000 3500 4000

0 500 1000 1500 2000 2500

4

6

8

10

12

14

16

0.2

0.3

0.4

0.5

0.6

0.0 0.2 0.4 0.6 0.8 1.01.0 1.20.000.020.040.060.080.100.120.140.16

16°

24°

32°

40°

8° 16°24°

32°

40°

72

76

76

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8-9

-14-7

-10-5-7

-5-3

-13-10

-20-16

-27-22

-35-31

8-6

-12-5-8

-4-7

-5-3

-13-9

-20-16

-27-20

-35-29

16-12-10

-6-6

-6-7

-5-6

-13-9

-15-12

-21-17

-27-24

16-10

-9-3-3

-6-6

-5-6

-12-9

-14-12

-21-17

-27-24

24 - 4024 - 40 24 - 4024 - 40-5-7

-6-5

-7-8

-8-7

-14-12

-18-16

-23-21

-28-27

-3-5

-5-2

-7-7

-7-7

-13-12

-17-16

-21-20

-26-26

74

73

0.4 0.6 0.8 1.0 1.20

2

0.0

0.1

70

69

71

74

76

76

75

JM AEROFOIL

Page 13: JM Aerofoil 50 Hz Technical

JM AEROFOIL

Motor Frame Size Schedules

Speed

rev/min

Pitch AngleRange

(°)Motor

MotorRating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Speed Regulation Details

Capacitor

µf

Speed Controller

Code

220-240 V / 50 Hz / 1 φ

Although motors are rated 220/240 V electrical supply capacitors should be rated µf x 450 V AC

Electronic Auto-Transformer

Pitch AngleRange

(°)

31JM/16/6/5/... 900 16-40 BT5 0.04 0.5 0.7 44 0.91 222-40 BT5 0.04 0.5 0.7 44 0.91 2 22-40 ME1.1 MT1.1

31JM/16/4/5/... 1420 12-36 BT5 0.07 0.6 1.8 60 0.92 424-38 BT5 0.07 0.6 1.8 60 0.92 4 24-38 ME1.1 MT1.1

31JM/16/2/5/... 2840 8-14 BT5 0.2 1.5 4 63 0.95 1018-20 BT5 0.3 2.1 5 64 0.95 1526-32 BT9 0.5 3.3 9 68 0.98 2036-40 CT5 0.75 4.9 8.5 71 0.93 20

35JM/16/6/5/... 900 12-40 BT5 0.04 0.5 0.7 44 0.91 2 12-40 ME1.1 MT1.1

35JM/16/4/5/... 1420 8-22 BT5 0.07 0.6 1.8 60 0.92 416-24 BT5 0.07 0.6 1.8 60 0.92 4 16-24 ME1.1 MT1.128-40 BT4 0.13 1 2 58 0.95 6 28-40 ME1.1 MT1.1

35JM/16/2/5/... 2840 10-12 BT5 0.3 2.1 5 64 0.95 1516-20 BT9 0.5 3.3 9 68 0.98 2024-28 CT5 0.75 4.9 8.5 71 0.93 2032-34 CT5 1 5.9 11.5 74 0.99 3036-40 CT9 1.4 8.3 27 74 0.99 50

40JM/16/6/5/... 900 8-28 BT5 0.04 0.5 0.7 44 0.91 2 8-28 ME1.1 MT1.132-40 BT5 0.09 0.8 1.6 50 0.95 5 32-40 ME1.1 MT1.1

40JM/16/4/5/... 1420 10-12 BT5 0.07 0.6 1.8 60 0.92 4 10-12 ME1.1 MT1.118-24 BT4 0.13 1 2 58 0.95 6 18-24 ME1.1 MT1.126-28 BT5 0.16 1.2 2.7 62 0.95 5 26-28 ME1.3 MT1.530-36 BT5 0.23 1.6 2.7 64 0.95 834-40 BT9 0.25 1.7 3.8 66 0.97 10 34-40 ME1.3 MT1.5

40JM/16/2/5/... 2840 10-10 BT9 0.5 3.3 9 68 0.98 2014-16 CT5 0.75 4.9 8.5 71 0.93 2020-22 CT5 1 5.9 11.5 74 0.99 3024-28 CT9 1.4 8.3 27 74 0.99 50

45JM/16/6/5/... 900 18-24 BT4 0.06 0.6 1 46 0.95 4 18-24 ME1.1 MT1.122-34 BT5 0.09 0.8 1.6 50 0.95 5 22-34 ME1.1 MT1.136-40 BT9 0.12 1.1 2.2 54 0.92 8 36-40 ME1.3 MT1.5

45JM/16/4/5/... 1420 10-14 BT4 0.13 1 2 58 0.95 6 10-14 ME1.1 MT1.118-18 BT5 0.16 1.2 2.7 62 0.95 5 18-18 ME1.3 MT1.522-22 BT5 0.2 1.5 2.7 62 0.95 8 22-22 ME1.3 MT1.524-26 BT9 0.25 1.7 3.8 66 0.97 10 24-26 ME1.3 MT1.524-30 BT9 0.3 2.1 5.3 65 0.95 10 24-30 ME1.3 MT1.536-40 CT5 0.45 2.9 7 68 0.99 15 36-40 ME1.3 MT1.5

45JM/16/2/5/... 2840 8-10 CT5 0.75 4.9 8.5 71 0.93 2012-14 CT5 1 5.9 11.5 74 0.99 3016-18 CT9 1.4 8.3 27 74 0.99 50

45JM/20/6/3/... 900 8-24 BT5 0.04 0.5 0.7 44 0.91 2 8-24 ME1.1 MT1.124-34 BT4 0.06 0.6 1 46 0.95 4 24-34 ME1.1 MT1.128-36 BT5 0.09 0.8 1.6 50 0.95 5 28-36 ME1.1 MT1.1

45JM/20/4/3/... 1420 10-12 BT5 0.07 0.6 1.8 60 0.92 4 10-12 ME1.1 MT1.116-22 BT4 0.13 1 2 58 0.95 6 16-22 ME1.1 MT1.124-26 BT5 0.16 1.2 2.7 62 0.95 5 24-26 ME1.3 MT1.530-30 BT5 0.2 1.5 2.7 62 0.95 8 30-30 ME1.3 MT1.532-36 BT9 0.25 1.7 3.8 66 0.97 10 32-36 ME1.3 MT1.5

45JM/20/2/3/... 2910 10-10 BT9 0.5 3.3 9 68 0.98 2014-16 CT5 0.75 4.9 8.5 71 0.93 2018-20 CT5 1 5.9 11.5 74 0.99 3022-24 CT9 1.4 8.3 27 74 0.99 50

Page 14: JM Aerofoil 50 Hz Technical

45JM/20/6/6/... 900 16-24 BT4 0.06 0.6 1 46 0.95 4 16-24 ME1.1 MT1.122-32 BT5 0.09 0.8 1.6 50 0.95 5 22-32 ME1.1 MT1.134-40 BT9 0.12 1.1 2.2 54 0.92 8 34-40 ME1.3 MT1.5

45JM/20/4/6/... 1420 10-12 BT4 0.13 1 2 58 0.95 6 10-12 ME1.1 MT1.116-16 BT5 0.16 1.2 2.7 62 0.95 5 16-16 ME1.3 MT1.522-28 BT9 0.3 2.1 5.3 65 0.95 10 22-28 ME1.3 MT1.534-40 CT5 0.45 2.9 7 68 0.99 15 34-40 ME1.3 MT1.5

45JM/20/2/6/... 2910 12-12 CT5 1 5.9 11.5 74 0.99 3014-16 CT9 1.4 8.3 27 74 0.99 50

50JM/16/6/5/... 915 16-22 BT5 0.09 0.8 1.6 50 0.95 5 16-22 ME1.1 MT1.124-28 BT9 0.12 1.1 2.2 54 0.92 8 24-28 ME1.3 MT1.530-32 BT9 0.14 1.2 2.8 54 0.92 8 30-32 ME1.3 MT1.536-40 CT5 0.19 1.8 3 48 0.96 8 36-40 ME1.3 MT1.5

50JM/16/4/5/... 1420 14-14 BT5 0.2 1.5 2.7 62 0.95 8 14-14 ME1.3 MT1.516-20 BT9 0.3 2.1 5.3 65 0.95 10 16-20 ME1.3 MT1.526-28 CT5 0.45 2.9 7 68 0.99 15 26-28 ME1.3 MT1.532-34 CT5 0.55 3.7 9.5 65 0.99 25 32-34 ME1.6 MT1.538-40 CT9 0.68 4.2 11 76 0.96 25 38-40 ME1.6 MT1.5

50JM/20/6/3/... 915 18-24 BT4 0.06 0.6 1 46 0.95 4 18-24 ME1.1 MT1.122-32 BT5 0.09 0.8 1.6 50 0.95 5 22-32 ME1.1 MT1.134-36 BT9 0.12 1.1 2.2 54 0.92 8 34-36 ME1.3 MT1.5

50JM/20/4/3/... 1420 12-14 BT4 0.13 1 2 58 0.95 6 12-14 ME1.1 MT1.116-18 BT5 0.16 1.2 2.7 62 0.95 5 16-18 ME1.3 MT1.524-30 BT9 0.3 2.1 5.3 65 0.95 10 24-30 ME1.3 MT1.534-36 CT5 0.45 2.9 7 68 0.99 15 34-36 ME1.3 MT1.5

50JM/20/2/3/... 2910 12-12 CT5 1 5.9 11.5 74 0.99 3014-16 CT9 1.4 8.3 27 74 0.99 50

50JM/20/6/6/... 915 10-14 BT4 0.06 0.6 1 46 0.95 4 10-14 ME1.1 MT1.114-22 BT5 0.09 0.8 1.6 50 0.95 5 14-22 ME1.1 MT1.124-26 BT9 0.12 1.1 2.2 54 0.92 8 24-26 ME1.3 MT1.528-30 BT9 0.14 1.2 2.8 54 0.92 8 28-30 ME1.3 MT1.534-40 CT5 0.19 1.8 3 48 0.96 8 34-40 ME1.3 MT1.5

50JM/20/4/6/... 1420 14-16 BT9 0.25 1.7 3.8 66 0.97 10 14-16 ME1.3 MT1.516-20 BT9 0.3 2.1 5.3 65 0.95 10 16-20 ME1.3 MT1.524-26 CT5 0.45 2.9 7 68 0.99 15 24-26 ME1.3 MT1.530-32 CT5 0.55 3.7 9.5 65 0.99 25 30-32 ME1.6 MT1.536-38 CT9 0.68 4.2 11 76 0.96 25 36-38 ME1.6 MT1.538-40 CT9 0.97 6.2 19 72 0.95 40 38-40 ME1.12 MT1.8

56JM/16/6/5/... 900 8-14 BT5 0.09 0.8 1.6 50 0.95 5 8-14 ME1.1 MT1.120-22 BT9 0.14 1.2 2.8 54 0.92 8 20-22 ME1.3 MT1.524-28 CT5 0.19 1.8 3 48 0.96 8 24-28 ME1.3 MT1.532-34 CT5 0.24 2.1 4 51 0.98 12 32-34 ME1.3 MT1.538-40 CT5 0.3 2.4 4 56 0.98 15 38-40 ME1.3 MT1.5

56JM/16/4/5/... 1420 10-12 BT9 0.3 2.1 5.3 65 0.95 10 10-12 ME1.3 MT1.516-18 CT5 0.45 2.9 7 68 0.99 15 16-18 ME1.3 MT1.522-22 CT5 0.55 3.7 9.5 65 0.99 25 22-22 ME1.6 MT1.524-26 CT9 0.7 5 15 64 0.96 40 24-26 ME1.6 MT1.828-32 CT9 0.97 6.2 19 72 0.95 40 28-32 ME1.12 MT1.836-38 CT9 1.1 7.2 23 70 0.95 50 36-38 N/A MT1.12

56JM/20/6/3/... 900 12-16 BT4 0.06 0.6 1 46 0.95 4 12-16 ME1.1 MT1.116-22 BT5 0.09 0.8 1.6 50 0.95 5 16-22 ME1.1 MT1.124-28 BT9 0.12 1.1 2.2 54 0.92 8 24-28 ME1.3 MT1.530-30 BT9 0.14 1.2 2.8 54 0.92 8 30-30 ME1.3 MT1.534-36 CT5 0.19 1.8 3 48 0.96 8 34-36 ME1.3 MT1.5

JM AEROFOIL

Motor Frame Size Schedules

Speed

rev/min

Pitch AngleRange

(°)Motor

MotorRating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Speed Regulation Details

Capacitor

µf

Speed Controller

Code

220-240 V / 50 Hz / 1 φ

Although motors are rated 220/240 V electrical supply capacitors should be rated µf x 450 V AC

Electronic Auto-Transformer

Pitch AngleRange

(°)

Page 15: JM Aerofoil 50 Hz Technical

56JM/20/4/3/... 1420 14-14 BT5 0.2 1.5 2.7 62 0.95 8 14-14 ME1.3 MT1.516-20 BT9 0.3 2.1 5.3 65 0.95 10 16-20 ME1.3 MT1.526-28 CT5 0.45 2.9 7 68 0.99 15 26-28 ME1.3 MT1.530-32 CT5 0.55 3.7 9.5 65 0.99 25 30-32 ME1.6 MT1.534-36 CT9 0.68 4.2 11 76 0.96 25 34-36 ME1.6 MT1.5

56JM/20/2/3/... 2910 14-18 F2225 2.7 14 50 84 0.98 90

56JM/20/6/6/... 900 8-12 BT5 0.09 0.8 1.6 50 0.95 5 8-12 ME1.1 MT1.116-18 BT9 0.12 1.1 2.2 54 0.92 8 16-18 ME1.3 MT1.520-20 BT9 0.14 1.2 2.8 54 0.92 8 20-20 ME1.3 MT1.524-26 CT5 0.19 1.8 3 48 0.96 8 24-26 ME1.3 MT1.530-32 CT5 0.24 2.1 4 51 0.98 12 30-32 ME1.3 MT1.536-38 CT5 0.3 2.4 4 56 0.98 15 36-38 ME1.3 MT1.5

56JM/20/4/6/... 1420 10-10 BT9 0.3 2.1 5.3 65 0.95 10 10-10 ME1.3 MT1.516-18 CT5 0.45 2.9 7 68 0.99 15 16-18 ME1.3 MT1.520-20 CT5 0.55 3.7 9.5 65 0.99 25 20-20 ME1.6 MT1.522-26 CT9 0.7 5 15 64 0.96 40 22-26 ME1.6 MT1.826-30 CT9 0.97 6.2 19 72 0.95 40 26-30 ME1.12 MT1.834-36 CT9 1.1 7.2 23 70 0.95 50 34-36 N/A MT1.12

63JM/20/6/3/... 900 8-10 BT5 0.09 0.8 1.6 50 0.95 5 8-10 ME1.1 MT1.112-14 BT9 0.12 1.1 2.2 54 0.92 8 12-14 ME1.3 MT1.516-16 BT9 0.14 1.2 2.8 54 0.92 8 16-16 ME1.3 MT1.520-22 CT5 0.19 1.8 3 48 0.96 8 20-22 ME1.3 MT1.526-26 CT5 0.24 2.1 4 51 0.98 12 26-26 ME1.3 MT1.50-32 CT5 0.3 2.4 4 56 0.98 15 30-32 ME1.3 MT1.5

63JM/20/4/3/... 1420 14-14 CT5 0.45 2.9 7 68 0.99 15 14-14 ME1.3 MT1.520-20 CT9 0.68 4.2 11 76 0.96 25 20-20 ME1.6 MT1.520-22 CT9 0.7 5 15 64 0.96 40 20-22 ME1.6 MT1.822-26 CT9 0.97 6.2 19 72 0.95 40 22-26 ME1.12 MT1.828-30 CT9 1.1 7.2 23 70 0.95 50 28-30 N/A MT1.12

63JM/20/6/6/... 900 12-14 CT5 0.19 1.8 3 48 0.96 8 12-14 ME1.3 MT1.518-18 CT5 0.24 2.1 4 51 0.98 12 18-18 ME1.3 MT1.522-22 CT5 0.3 2.4 4 56 0.98 15 22-22 ME1.3 MT1.528-30 CT9 0.43 3.3 7.5 59 0.96 15 28-30 ME1.6 MT1.534-34 CT9 0.52 4 9.2 59 0.95 20 34-34 ME1.6 MT1.8

63JM/20/4/6/... 1420 12-12 CT9 0.7 5 15 64 0.96 40 12-12 ME1.6 MT1.814-16 CT9 0.97 6.2 19 72 0.95 40 14-16 ME1.12 MT1.820-22 CT9 1.1 7.2 23 70 0.95 50 20-22 N/A MT1.12

71JM/20/6/3/... 900 12-12 CT5 0.19 1.8 3 48 0.96 8 12-12 ME1.3 MT1.516-18 CT5 0.24 2.1 4 51 0.98 12 16-18 ME1.3 MT1.520-22 CT5 0.3 2.4 4 56 0.98 15 20-22 ME1.3 MT1.526-28 CT9 0.43 3.3 7.5 59 0.96 15 26-28 ME1.6 MT1.532-32 CT9 0.52 4 9.2 59 0.95 20 32-32 ME1.6 MT1.8

71JM/20/4/3/... 1440 12-12 CT9 0.7 5 15 64 0.96 40 12-12 ME1.6 MT1.814-16 CT9 0.97 6.2 19 72 0.95 40 14-16 ME1.12 MT1.820-20 CT9 1.1 7.2 23 70 0.95 50 20-20 N/A MT1.12

71JM/20/6/6/... 900 12-12 CT5 0.3 2.4 4 56 0.98 15 12-12 ME1.3 MT1.518-18 CT9 0.43 3.3 7.5 59 0.96 15 18-18 ME1.6 MT1.522-22 CT9 0.52 4 9.2 59 0.95 20 22-22 ME1.6 MT1.8

80JM/20/6/3/... 935 14-14 CT5 0.3 2.4 4 56 0.98 15 14-14 ME1.3 MT1.518-20 CT9 0.43 3.3 7.5 59 0.96 15 18-20 ME1.6 MT1.5

JM AEROFOIL

Motor Frame Size Schedules

Speed

rev/min

Pitch AngleRange

(°)Motor

MotorRating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Speed Regulation Details

Capacitor

µf

Speed Controller

Code

220-240 V / 50 Hz / 1 φ

Although motors are rated 220/240 V electrical supply capacitors should be rated µf x 450 V AC

Electronic Auto-Transformer

Pitch AngleRange

(°)

Page 16: JM Aerofoil 50 Hz Technical

JM AEROFOIL

Motor Frame Size Schedules

380-420 V / 50 Hz / 3 φ

Speed

rev/min

Pitch AngleRange

(°)Motor

MotorRating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Speed Regulation DetailsSpeed Controller

Code Electronic Auto-Transformer

Pitch AngleRange

(°)

31JM/16/6/5/... 900 40 BT4 0.06 0.3 0.8 46 0.6 NR at this angle

31JM/16/4/5/... 1420 40 BT4 0.13 0.5 1.8 58 0.7 34-40 ME3.5S MT3.0.5

31JM/16/2/5/... 2840 24 BT5 0.35 0.9 3.6 66 0.8536 BT9 0.58 1.4 6 71 0.8540 CT5 0.95 2 9.5 75 0.9

35JM/16/6/5/... 900 40 BT4 0.06 0.3 0.8 46 0.6 28-40 ME3.5S MT3.0.5

35JM/16/4/5/... 1420 40 BT4 0.13 0.5 1.8 58 0.7 22-40 ME3.5S MT3.0.5

35JM/16/2/5/... 2840 14 BT5 0.35 0.9 3.6 66 0.8522 BT9 0.58 1.4 6 71 0.8534 CT5 0.95 2 9.5 75 0.940 CT9 1.7 3.5 20 78 0.9

40JM/16/6/5/... 900 38 BT4 0.06 0.3 0.8 46 0.6 18-38 ME3.5S MT3.0.540 BT5 0.09 0.5 1.2 50 0.58 36-40 ME3.2D MT3.0.5

40JM/16/4/5/... 1420 24 BT4 0.13 0.5 1.8 58 0.7 14-24 ME3.5S MT3.0.534 BT5 0.2 0.7 2.4 62 0.7 26-34 ME3.2D MT3.140 BT9 0.3 0.9 4.6 65 0.75 36-40 ME3.2D MT3.1

40JM/16/2/5/... 2840 12 BT9 0.58 1.4 6 71 0.8520 CT5 0.95 2 9.5 75 0.932 CT9 1.7 3.5 20 78 0.9

45JM/16/6/5/... 900 24 BT4 0.06 0.3 0.8 46 0.6 10-24 ME3.5S MT3.0.534 BT5 0.09 0.5 1.2 50 0.58 26-34 ME3.2D MT3.0.540 BT9 0.14 0.6 1.8 54 0.66 36-40 ME3.2D MT3.1

45JM/16/4/5/... 1420 14 BT4 0.13 0.5 1.8 58 0.7 8-14 ME3.5S MT3.0.522 BT5 0.2 0.7 2.4 62 0.7 16-22 ME3.2D MT3.130 BT9 0.3 0.9 4.6 65 0.75 24-30 ME3.2D MT3.140 CT5 0.58 1.7 6.5 67 0.74 40-40 ME3.2D MT3.2

45JM/16/2/5/... 2840 12 CT5 0.95 2 9.5 75 0.920 CT9 1.7 3.5 20 78 0.9

45JM/20/6/3/... 900 34 BT4 0.06 0.3 0.8 46 0.6 16-34 ME3.5S MT3.0.536 BT5 0.09 0.5 1.2 50 0.58 32-36 ME3.2D MT3.0.5

45JM/20/4/3/... 1420 22 BT4 0.13 0.5 1.8 58 0.7 12-22 ME3.5S MT3.0.530 BT5 0.2 0.7 2.4 62 0.7 22-30 ME3.2D MT3.136 BT9 0.3 0.9 4.6 65 0.75 32-36 ME3.2D MT3.1

45JM/20/2/3/... 2910 12 BT9 0.58 1.4 6 71 0.8518 CT5 0.95 2 9.5 75 0.928 CT9 1.7 3.5 20 78 0.936 F2225 3.8 7.2 64 88 0.87

45JM/20/6/6/... 900 24 BT4 0.06 0.3 0.8 46 0.6 10-24 ME3.5S MT3.0.532 BT5 0.09 0.5 1.2 50 0.58 26-32 ME3.2D MT3.0.540 BT9 0.14 0.6 1.8 54 0.66 34-40 ME3.2D MT3.1

45JM/20/4/6/... 1420 12 BT4 0.13 0.5 1.8 58 0.7 8-12 ME3.5S MT3.0.520 BT5 0.2 0.7 2.4 62 0.7 14-20 ME3.2D MT3.128 BT9 0.3 0.9 4.6 65 0.75 22-28 ME3.2D MT3.140 CT5 0.58 1.7 6.5 67 0.74 38-40 ME3.2D MT3.2

Page 17: JM Aerofoil 50 Hz Technical

JM AEROFOIL

Motor Frame Size Schedules

380-420 V / 50 Hz / 3 φ

Speed

rev/min

Pitch AngleRange

(°)Motor

MotorRating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Speed Regulation DetailsSpeed Controller

Code Electronic Auto-Transformer

Pitch AngleRange

(°)

45JM/20/2/6/... 2910 12 CT5 0.95 2 9.5 75 0.920 CT9 1.7 3.5 20 78 0.936 F2225 3.8 7.2 64 88 0.8740 PM112 6.2 11.6 100 88 0.87

50JM/16/6/5/... 915 16 BT4 0.06 0.3 0.8 46 0.6 8-16 ME3.5S MT3.0.522 BT5 0.09 0.5 1.2 50 0.58 18-22 ME3.2D MT3.0.532 BT9 0.14 0.6 1.8 54 0.66 24-32 ME3.2D MT3.140 CT5 0.22 0.8 2.5 55 0.7 36-40 ME3.2D MT3.1

50JM/16/4/5/... 1420 14 BT5 0.2 0.7 2.4 62 0.7 10-14 ME3.2D MT3.120 BT9 0.3 0.9 4.6 65 0.75 16-20 ME3.2D MT3.134 CT5 0.58 1.7 6.5 67 0.74 28-34 ME3.2D MT3.240 CT9 0.9 2.3 9 72 0.78 36-40 ME3.2D MT3.2

50JM/20/6/3/... 915 24 BT4 0.06 0.3 0.8 46 0.6 10-24 ME3.5S MT3.0.532 BT5 0.09 0.5 1.2 50 0.58 26-32 ME3.2D MT3.0.536 BT9 0.14 0.6 1.8 54 0.66 34-36 ME3.2D MT3.1

50JM/20/4/3/... 1420 14 BT4 0.13 0.5 1.8 58 0.7 8-14 ME3.5S MT3.0.522 BT5 0.2 0.7 2.4 62 0.7 16-22 ME3.2D MT3.130 BT9 0.3 0.9 4.6 65 0.75 24-30 ME3.2D MT3.136 CT5 0.58 1.7 6.5 67 0.74 36-36 ME3.2D MT3.2

50JM/20/2/3/... 2910 12 CT5 0.95 2 9.5 75 0.920 CT9 1.7 3.5 20 78 0.934 F2225 3.8 7.2 64 88 0.8736 PM112 6.2 11.6 100 88 0.87

50JM/20/6/6/... 915 14 BT4 0.06 0.3 0.8 46 0.6 8-14 ME3.5S MT3.0.522 BT5 0.09 0.5 1.2 50 0.58 18-22 ME3.2D MT3.0.530 BT9 0.14 0.6 1.8 54 0.66 24-30 ME3.2D MT3.140 CT5 0.22 0.8 2.5 55 0.7 34-40 ME3.2D MT3.1

50JM/20/4/6/... 1420 12 BT5 0.2 0.7 2.4 62 0.7 10-12 ME3.2D MT3.120 BT9 0.3 0.9 4.6 65 0.75 16-20 ME3.2D MT3.124 BT9 0.39 1.1 4.6 67 0.7532 CT5 0.58 1.7 6.5 67 0.74 26-32 ME3.2D MT3.236 CT5 0.71 1.9 6.5 71 0.7540 CT9 0.9 2.3 9 72 0.78 34-40 ME3.2D MT3.2

50JM/20/2/6/... 2910 12 CT9 1.7 3.5 20 78 0.924 F2225 3.8 7.2 64 88 0.8734 PM112 6.2 11.6 100 88 0.87

56JM/16/8/5/... 680 12 BT5 0.032 0.2 0.4 34 0.57 10-12 ME3.5S MT3.0.524 BT5 0.065 0.5 0.8 34 0.57 20-24 ME3.5S MT3.0.532 BT9 0.09 0.5 0.9 42 0.57 26-32 ME3.2D MT3.140 CT5 0.13 0.7 1.5 47 0.6 34-40 ME3.2D MT3.1

56JM/16/6/5/... 900 14 BT5 0.09 0.5 1.2 50 0.58 10-14 ME3.2D MT3.0.522 BT9 0.14 0.6 1.8 54 0.66 16-22 ME3.2D MT3.132 CT5 0.22 0.8 2.5 55 0.7 24-32 ME3.2D MT3.140 CT5 0.3 1.1 3.3 56 0.7 34-40 ME3.2D MT3.2

56JM/16/4/5/... 1420 12 BT9 0.3 0.9 4.6 65 0.75 10-12 ME3.2D MT3.124 CT5 0.58 1.7 6.5 67 0.74 18-24 ME3.2D MT3.232 CT9 0.9 2.3 9 72 0.78 26-32 ME3.2D MT3.240 CT9 1.15 3 14 71 0.78 34-40 ME3.2D N/A

56JM/20/6/3/... 900 16 BT4 0.06 0.3 0.8 46 0.6 8-16 ME3.5S MT3.0.522 BT5 0.09 0.5 1.2 50 0.58 18-22 ME3.2D MT3.0.530 BT9 0.14 0.6 1.8 54 0.66 24-30 ME3.2D MT3.136 CT5 0.22 0.8 2.5 55 0.7 34-36 ME3.2D MT3.1

Page 18: JM Aerofoil 50 Hz Technical

JM AEROFOIL

Motor Frame Size Schedules

380-420 V / 50 Hz / 3 φ

Speed

rev/min

Pitch AngleRange

(°)Motor

MotorRating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Speed Regulation DetailsSpeed Controller

Code Electronic Auto-Transformer

Pitch AngleRange

(°)

56JM/20/4/3/... 1420 14 BT5 0.2 0.7 2.4 62 0.7 10-14 ME3.2D MT3.120 BT9 0.3 0.9 4.6 65 0.75 16-20 ME3.2D MT3.124 BT9 0.39 1.1 4.6 67 0.7532 CT5 0.58 1.7 6.5 67 0.74 28-32 ME3.2D MT3.234 CT5 0.71 1.9 6.5 71 0.7536 CT9 0.9 2.3 9 72 0.78 34-36 ME3.2D MT3.2

56JM/20/2/3/... 2910 12 CT9 1.7 3.5 20 78 0.926 F2225 3.8 7.2 64 88 0.8734 PM112 6.2 11.6 100 88 0.87

56JM/20/6/6/... 900 12 BT5 0.09 0.5 1.2 50 0.58 10-12 ME3.2D MT3.0.520 BT9 0.14 0.6 1.8 54 0.66 16-20 ME3.2D MT3.130 CT5 0.22 0.8 2.5 55 0.7 24-30 ME3.2D MT3.138 CT5 0.3 1.1 3.3 56 0.7 32-38 ME3.2D MT3.240 CT9 0.4 1.5 5.3 66 0.6 40-40 ME3.2D MT3.2

56JM/20/4/6/... 1420 10 BT9 0.3 0.9 4.6 65 0.75 10-10 ME3.2D MT3.114 BT9 0.39 1.1 4.6 67 0.7522 CT5 0.58 1.7 6.5 67 0.74 18-22 ME3.2D MT3.224 CT5 0.71 1.9 6.5 71 0.7530 CT9 0.9 2.3 9 72 0.78 24-30 ME3.2D MT3.236 CT9 1.15 3 14 71 0.78 32-36 ME3.2D N/A40 CT9 1.4 3.5 14 74 0.77

56JM/20/2/6/... 2910 16 F2225 3.8 7.2 64 88 0.8724 PM112 6.2 11.6 100 88 0.87

63JM/20/8/3/... 680 18 BT5 0.065 0.5 0.8 34 0.57 16-18 ME3.5S MT3.0.524 BT9 0.09 0.5 0.9 42 0.57 20-24 ME3.2D MT3.132 CT5 0.13 0.7 1.5 47 0.6 26-32 ME3.2D MT3.136 CT9 0.18 0.7 1.7 56 0.66 34-36 ME3.2D MT3.1

63JM/20/6/3/... 900 10 BT5 0.09 0.5 1.2 50 0.58 8-10 ME3.2D MT3.0.516 BT9 0.14 0.6 1.8 54 0.66 12-16 ME3.2D MT3.126 CT5 0.22 0.8 2.5 55 0.7 20-26 ME3.2D MT3.132 CT5 0.3 1.1 3.3 56 0.7 28-32 ME3.2D MT3.236 CT9 0.4 1.5 5.3 66 0.6 34-36 ME3.2D MT3.2

63JM/20/4/3/... 1420 18 CT5 0.58 1.7 6.5 67 0.74 14-18 ME3.2D MT3.220 CT5 0.71 1.9 6.5 71 0.7526 CT9 0.9 2.3 9 72 0.78 20-26 ME3.2D MT3.230 CT9 1.15 3 14 71 0.78 28-30 ME3.2D N/A34 CT9 1.4 3.5 14 74 0.77

63JM/20/8/6/... 680 10 BT5 0.065 0.5 0.8 34 0.57 10-10 ME3.5S MT3.0.516 BT9 0.09 0.5 0.9 42 0.57 14-16 ME3.2D MT3.122 CT5 0.13 0.7 1.5 47 0.6 18-22 ME3.2D MT3.130 CT9 0.18 0.7 1.7 56 0.66 24-30 ME3.2D MT3.136 CT9 0.25 1.2 2.6 50 0.6 32-36 ME3.2D MT3.2

63JM/20/6/6/... 900 8 BT9 0.14 0.6 1.8 54 0.66 8- 8 ME3.2D MT3.118 CT5 0.22 0.8 2.5 55 0.7 12-18 ME3.2D MT3.122 CT5 0.3 1.1 3.3 56 0.7 20-22 ME3.2D MT3.228 CT9 0.4 1.5 5.3 66 0.6 24-28 ME3.2D MT3.234 CT9 0.52 1.7 7.5 59 0.74 30-34 ME3.2D MT3.2

63JM/20/4/6/... 1420 10 CT5 0.58 1.7 6.5 67 0.74 10-10 ME3.2D MT3.212 CT5 0.71 1.9 6.5 71 0.7518 CT9 0.9 2.3 9 72 0.78 14-18 ME3.2D MT3.222 CT9 1.15 3 14 71 0.78 20-22 ME3.2D N/A24 CT9 1.4 3.5 14 74 0.7734 F2245 2.1 5 27 79 0.7736 F2245 2.7 5.8 30 82 0.82

Page 19: JM Aerofoil 50 Hz Technical

JM AEROFOIL

Motor Frame Size Schedules

380-420 V / 50 Hz / 3 φ

Speed

rev/min

Pitch AngleRange

(°)Motor

MotorRating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Speed Regulation DetailsSpeed Controller

Code Electronic Auto-Transformer

Pitch AngleRange

(°)

63JM/25/2/3/... 2910 16 F2225 3.8 7.2 64 88 0.8722 PM112 6.2 11.6 100 88 0.8730 132S 8.6 15.6 98.9 89 0.8932 160M 13 23.1 163 89 0.89

63JM/25/4/6/... 1440 36 F2245 2.1 5 27 79 0.77

63JM/25/2/6/... 2910 10 F2225 3.8 7.2 64 88 0.8716 PM112 6.2 11.6 100 88 0.8720 132S 8.6 15.6 98.9 89 0.8926 160M 13 23.1 163 89 0.8934 160M 17 30.1 175 91 0.9136 160L 21 36.1 263 92 0.92

63JM/25/6/9/... 935 40 F2265 1.35 3.6 15 77 0.71

63JM/25/4/9/... 1440 32 F2245 2.1 5 27 79 0.7736 F2245 2.7 5.8 30 82 0.8240 PM112 4.4 9.3 55 84 0.81

63JM/25/2/9/... 2910 10 PM112 6.2 11.6 100 88 0.8716 132S 8.6 15.6 98.9 89 0.8922 160M 13 23.1 163 89 0.8928 160M 17 30.1 175 91 0.9132 160L 21 36.1 263 92 0.92

71JM/20/8/3/... 680 22 CT5 0.13 0.7 1.5 47 0.6 18-22 ME3.2D MT3.136 CT9 0.25 1.2 2.6 50 0.6 30-36 ME3.2D MT3.2

71JM/20/6/3/... 900 22 CT5 0.3 1.1 3.3 56 0.7 18-22 ME3.2D MT3.226 CT9 0.4 1.5 5.3 66 0.6 24-26 ME3.2D MT3.232 CT9 0.52 1.7 7.5 59 0.74 28-32 ME3.2D MT3.236 F2265 1.35 3.6 15 77 0.71

71JM/20/4/3/... 1440 10 CT5 0.71 1.9 6.5 71 0.7516 CT9 0.9 2.3 9 72 0.78 12-16 ME3.2D MT3.222 CT9 1.4 3.5 14 74 0.7732 F2245 2.1 5 27 79 0.7736 F2245 2.7 5.8 30 82 0.82

71JM/20/8/6/... 680 12 CT5 0.13 0.7 1.5 47 0.6 10-12 ME3.2D MT3.124 CT9 0.25 1.2 2.6 50 0.6 20-24 ME3.2D MT3.236 F2265 0.65 2.4 8 64 0.62

71JM/20/6/6/... 900 12 CT5 0.3 1.1 3.3 56 0.7 12-12 ME3.2D MT3.222 CT9 0.52 1.7 7.5 59 0.74 20-22 ME3.2D MT3.224 CT9 0.68 2.2 7.5 60 0.7336 F2265 1.35 3.6 15 77 0.71

71JM/20/4/6/... 1440 12 CT9 1.15 3 14 71 0.78 12-12 ME3.2D N/A22 F2245 2.1 5 27 79 0.7724 F2245 2.7 5.8 30 82 0.8236 PM112 4.4 9.3 55 84 0.81

71JM/25/4/3/... 1440 32 F2245 2.1 5 27 79 0.77

71JM/25/8/6/... 695 36 F2265 0.4 1.5 5 63 0.61 30-36 ME3.2D MT3.2

71JM/25/6/6/... 935 36 F2265 1.35 3.6 15 77 0.71

Page 20: JM Aerofoil 50 Hz Technical

JM AEROFOIL

Motor Frame Size Schedules

380-420 V / 50 Hz / 3 φ

Speed

rev/min

Pitch AngleRange

(°)Motor

MotorRating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Speed Regulation DetailsSpeed Controller

Code Electronic Auto-Transformer

Pitch AngleRange

(°)

71JM/25/4/6/... 1440 26 F2245 2.1 5 27 79 0.7728 F2245 2.7 5.8 30 82 0.8236 PM112 4.4 9.3 55 84 0.81

71JM/25/8/9/... 695 36 F2265 0.65 2.4 8 64 0.62

71JM/25/6/9/... 935 36 F2265 1.35 3.6 15 77 0.71

71JM/25/4/9/... 1440 18 F2245 2.1 5 27 79 0.7722 F2245 2.7 5.8 30 82 0.8232 PM112 4.4 9.3 55 84 0.8136 132S 6.3 12.7 86 87 0.82

71JM/31/2/9/... 2910 12 160M 13 23.1 163 89 0.8916 160M 17 30.1 175 91 0.9120 160L 21 36.1 263 92 0.9224 180MA 25 44 313 93 0.89

80JM/20/8/3/... 695 14 CT5 0.13 0.7 1.5 47 0.6 12-14 ME3.2D MT3.120 CT9 0.18 0.7 1.7 56 0.66 16-20 ME3.2D MT3.124 CT9 0.25 1.2 2.6 50 0.6 22-24 ME3.2D MT3.236 F2265 0.65 2.4 8 64 0.62

80JM/20/6/3/... 935 14 CT5 0.3 1.1 3.3 56 0.7 12-14 ME3.2D MT3.222 CT9 0.52 1.7 7.5 59 0.74 20-22 ME3.2D MT3.236 F2265 1.35 3.6 15 77 0.71

80JM/20/4/3/... 1440 12 CT9 1.15 3 14 71 0.78 12-12 ME3.2D N/A14 CT9 1.4 3.5 14 74 0.7722 F2245 2.1 5 27 79 0.7724 F2245 2.7 5.8 30 82 0.8236 PM112 4.4 9.3 55 84 0.81

80JM/20/8/6/... 695 16 CT9 0.25 1.2 2.6 50 0.6 14-16 ME3.2D MT3.228 F2265 0.65 2.4 8 64 0.6234 F2265 0.8 3 11 66 0.58

80JM/20/6/6/... 935 12 CT9 0.52 1.7 7.5 59 0.74 12-12 ME3.2D MT3.214 CT9 0.68 2.2 7.5 60 0.7326 F2265 1.35 3.6 15 77 0.7128 F2265 1.55 4.1 17 76 0.7236 F2269 2.1 5.7 24 77 0.69

80JM/20/4/6/... 1440 12 F2245 2.1 5 27 79 0.7716 F2245 2.7 5.8 30 82 0.8224 PM112 4.4 9.3 55 84 0.81

80JM/25/8/3/... 695 32 F2265 0.4 1.5 5 63 0.61 30-32 ME3.2D MT3.2

80JM/25/6/3/... 935 32 F2265 1.35 3.6 15 77 0.71

80JM/25/4/3/... 1440 26 F2245 2.1 5 27 79 0.7730 F2245 2.7 5.8 30 82 0.8232 PM112 4.4 9.3 55 84 0.81

80JM/25/8/6/... 695 32 F2265 0.65 2.4 8 64 0.6236 F2265 0.8 3 11 66 0.58

80JM/25/6/6/... 935 30 F2265 1.35 3.6 15 77 0.7132 F2265 1.55 4.1 17 76 0.7236 F2269 2.1 5.7 24 77 0.69

Page 21: JM Aerofoil 50 Hz Technical

JM AEROFOIL

Motor Frame Size Schedules

380-420 V / 50 Hz / 3 φ

Speed

rev/min

Pitch AngleRange

(°)Motor

MotorRating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Speed Regulation DetailsSpeed Controller

Code Electronic Auto-Transformer

Pitch AngleRange

(°)

80JM/25/4/6/... 1440 16 F2245 2.1 5 27 79 0.7720 F2245 2.7 5.8 30 82 0.8228 PM112 4.4 9.3 55 84 0.8134 132S 6.3 12.7 86 87 0.8236 132M 8.6 16.6 112 89 0.85

80JM/25/8/9/... 695 26 F2265 0.65 2.4 8 64 0.6236 F2269 0.85 3 11 64 0.64 32-36 ME3.2D N/A

80JM/25/6/9/... 935 24 F2265 1.35 3.6 15 77 0.7126 F2265 1.55 4.1 17 76 0.7234 F2269 2.1 5.7 24 77 0.6936 F2269 2.5 6.4 26 76 0.74

80JM/25/4/9/... 1440 10 F2245 2.1 5 27 79 0.7712 F2245 2.7 5.8 30 82 0.8222 PM112 4.4 9.3 55 84 0.8128 132S 6.3 12.7 86 87 0.8234 132M 8.6 16.6 112 89 0.8536 160M 13 23.4 165 91 0.86

80JM/31/2/9/... 2910 10 160M 17 30.1 175 91 0.9112 160L 21 36.1 263 92 0.9214 180MA 25 44 313 93 0.89

90JM/25/8/3/... 695 32 F2265 0.65 2.4 8 64 0.62

90JM/25/6/3/... 935 30 F2265 1.35 3.6 15 77 0.71

90JM/25/4/3/... 1440 18 F2245 2.1 5 27 79 0.7720 F2245 2.7 5.8 30 82 0.8228 PM112 4.4 9.3 55 84 0.8132 132S 6.3 12.7 86 87 0.82

90JM/25/8/6/... 695 22 F2265 0.65 2.4 8 64 0.6226 F2265 0.8 3 11 66 0.5832 F2269 0.85 3 11 64 0.64 28-32 ME3.2D N/A

90JM/25/6/6/... 935 20 F2265 1.35 3.6 15 77 0.7122 F2265 1.55 4.1 17 76 0.7228 F2269 2.1 5.7 24 77 0.6932 F2269 2.5 6.4 26 76 0.74

90JM/25/4/6/... 1440 8 F2245 2.1 5 27 79 0.7710 F2245 2.7 5.8 30 82 0.8218 PM112 4.4 9.3 55 84 0.8124 132S 6.3 12.7 86 87 0.8230 132M 8.6 16.6 112 89 0.8532 160M 13 23.4 165 91 0.86

90JM/25/8/9/... 695 16 F2265 0.65 2.4 8 64 0.6218 F2265 0.8 3 11 66 0.5824 F2269 0.85 3 11 64 0.64 20-24 ME3.2D N/A26 F2269 1.1 3.9 13 69 0.5932 F2269 1.4 4.9 18 70 0.5936 132S 2.5 5.8 26.2 82 0.76

90JM/25/6/9/... 935 14 F2265 1.35 3.6 15 77 0.7116 F2265 1.55 4.1 17 76 0.7220 F2269 2.1 5.7 24 77 0.6926 F2269 2.5 6.4 26 76 0.7430 132S 3.5 7.2 41 86 0.836 132M 4.6 10.1 58.9 84 0.78

Page 22: JM Aerofoil 50 Hz Technical

JM AEROFOIL

Motor Frame Size Schedules

380-420 V / 50 Hz / 3 φ

Speed

rev/min

Pitch AngleRange

(°)Motor

MotorRating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Speed Regulation DetailsSpeed Controller

Code Electronic Auto-Transformer

Pitch AngleRange

(°)

90JM/25/4/9/... 1440 10 PM112 4.4 9.3 55 84 0.8116 132S 6.3 12.7 86 87 0.8222 132M 8.6 16.6 112 89 0.8532 160M 13 23.4 165 91 0.8636 160L 17 32.1 226 91 0.85

100JM/25/8/3/... 695 24 F2265 0.65 2.4 8 64 0.6228 F2265 0.8 3 11 66 0.5832 F2269 0.85 3 11 64 0.64 28-32 ME3.2D N/A32 F2269 1.1 3.9 13 69 0.59

100JM/25/6/3/... 935 22 F2265 1.35 3.6 15 77 0.7124 F2265 1.55 4.1 17 76 0.7230 F2269 2.1 5.7 24 77 0.6932 F2269 2.5 6.4 26 76 0.74

100JM/25/4/3/... 1440 10 F2245 2.1 5 27 79 0.7712 F2245 2.7 5.8 30 82 0.8220 PM112 4.4 9.3 55 84 0.8126 132S 6.3 12.7 86 87 0.8232 132M 8.6 16.6 112 89 0.85

100JM/25/8/6/... 695 14 F2265 0.65 2.4 8 64 0.6218 F2265 0.8 3 11 66 0.5822 F2269 0.85 3 11 64 0.64 20-22 ME3.2D N/A24 F2269 1.1 3.9 13 69 0.5928 F2269 1.4 4.9 18 70 0.5932 132S 2.5 5.8 26.2 82 0.76

100JM/25/6/6/... 950 12 F2265 1.35 3.6 15 77 0.7114 F2265 1.55 4.1 17 76 0.7224 F2269 2.5 6.4 26 76 0.7428 132S 3.5 7.2 41 86 0.832 132M 4.6 10.1 58.9 84 0.78

100JM/25/4/6/... 1450 10 PM112 4.4 9.3 55 84 0.8116 132S 6.3 12.7 86 87 0.8222 132M 8.6 16.6 112 89 0.8528 160M 13 23.4 165 91 0.8632 160L 17 32.1 226 91 0.85

100JM/25/8/9/... 695 12 F2265 0.8 3 11 66 0.5816 F2269 0.85 3 11 64 0.64 14-16 ME3.2D N/A18 F2269 1.1 3.9 13 69 0.5922 F2269 1.4 4.9 18 70 0.5934 132S 2.5 5.8 26.2 82 0.7636 132M 3.5 8.7 44.4 84 0.68

100JM/25/6/9/... 960 8 F2265 1.55 4.1 17 76 0.7214 F2269 2.1 5.7 24 77 0.6918 F2269 2.5 6.4 26 76 0.7420 132S 3.5 7.2 41 86 0.826 132M 4.6 10.1 58.9 84 0.7834 132M 6.3 13.7 87.2 87 0.7736 160M 8.6 18 112 89 0.78

100JM/25/4/9/... 1470 10 132S 6.3 12.7 86 87 0.8214 132M 8.6 16.6 112 89 0.8522 160M 13 23.4 165 91 0.8626 160L 17 32.1 226 91 0.85

Page 23: JM Aerofoil 50 Hz Technical

JM AEROFOIL

Motor Frame Size Schedules

380-420 V / 50 Hz / 3 φ

Speed

rev/min

Pitch AngleRange

(°)Motor

MotorRating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Speed Regulation DetailsSpeed Controller

Code Electronic Auto-Transformer

Pitch AngleRange

(°)

100JM/31/4/9/... 1470 10 132S 6.3 12.7 86 87 0.8214 132M 8.6 16.6 112 89 0.8522 160M 13 23.4 165 91 0.8626 160L 17 32.1 226 91 0.8532 180MC 21 39.7 249 91 0.8536 180L 25 45.5 307 93 0.87

100JM/40/4/9/... 1470 12 132M 8.6 16.6 112 89 0.8518 160M 13 23.4 165 91 0.8624 160L 17 32.1 226 91 0.8528 180MC 21 39.7 249 91 0.8532 180L 25 45.5 307 93 0.8740 200LC 35 62.1 428 93 0.86

Page 24: JM Aerofoil 50 Hz Technical

JM AEROFOIL

Speed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

Motor Frame Size Schedules

380-420 V / 50 Hz / 3 φ

112JM/40/8/6/... 720 24 132S 2.5 5.8 26.2 82 0.7630 132M 3.5 8.7 44.4 84 0.6832 160M 4.6 10.2 54.5 86 0.76

112JM/40/6/6/... 960 14 132S 3.5 7.2 41 86 0.818 132M 4.6 10.1 58.9 84 0.7824 132M 6.3 13.7 87.2 87 0.7730 160M 8.6 18 112 89 0.7832 160L 13 24.8 165 90 0.82

112JM/40/4/6/... 1470 10 132M 8.6 16.6 112 89 0.8514 160M 13 23.4 165 91 0.8620 160L 17 32.1 226 91 0.8524 180MC 21 39.7 249 91 0.8526 180L 25 45.5 307 93 0.8732 200LC 35 62.1 428 93 0.86

112JM/40/8/9/... 720 20 132S 2.5 5.8 26.2 82 0.7624 132M 3.5 8.7 44.4 84 0.6830 160M 4.6 10.2 54.5 86 0.7636 160M 6.3 13.6 73.1 87 0.77

112JM/40/6/9/... 960 10 132S 3.5 7.2 41 86 0.814 132M 4.6 10.1 58.9 84 0.7820 132M 6.3 13.7 87.2 87 0.7724 160M 8.6 18 112 89 0.7832 160L 13 24.8 165 90 0.8236 180L 17 32.8 191 91 0.84

112JM/40/4/9/... 1470 10 160M 13 23.4 165 91 0.8614 160L 17 32.1 226 91 0.8518 180MC 21 39.7 249 91 0.8522 180L 25 45.5 307 93 0.8728 200LC 35 62.1 428 93 0.8632 225SC 43 78.3 466 93 0.8436 225MC 52 93.8 517 93 0.86

112JM/50/8/12/... 720 18 132S 2.5 5.8 26.2 82 0.7624 132M 3.5 8.7 44.4 84 0.6828 160M 4.6 10.2 54.5 86 0.7636 160M 6.3 13.6 73.1 87 0.77

112JM/50/6/12/... 960 8 132S 3.5 7.2 41 86 0.812 132M 4.6 10.1 58.9 84 0.7818 132M 6.3 13.7 87.2 87 0.7722 160M 8.6 18 112 89 0.7830 160L 13 24.8 165 90 0.8236 180L 17 32.8 191 91 0.84

112JM/50/4/12/... 1470 8 160M 13 23.4 165 91 0.8612 160L 17 32.1 226 91 0.8516 180MC 21 39.7 249 91 0.8520 180L 25 45.5 307 93 0.8726 200LC 35 62.1 428 93 0.8630 225SC 43 78.3 466 93 0.8434 225MC 52 93.8 517 93 0.8636 250SC 63 113 782 94 0.86

125JM/40/8/6/... 720 18 132S 2.5 5.8 26.2 82 0.7622 132M 3.5 8.7 44.4 84 0.6826 160M 4.6 10.2 54.5 86 0.7632 160M 6.3 13.6 73.1 87 0.77

Page 25: JM Aerofoil 50 Hz Technical

Motor Frame Size Schedules

380-420 V / 50 Hz / 3 φ

Speed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

125JM/40/6/6/... 960 8 132S 3.5 7.2 41 86 0.812 132M 4.6 10.1 58.9 84 0.7816 132M 6.3 13.7 87.2 87 0.7720 160M 8.6 18 112 89 0.7828 160L 13 24.8 165 90 0.8232 180L 17 32.8 191 91 0.84

125JM/40/4/6/... 1470 8 160M 13 23.4 165 91 0.8612 160L 17 32.1 226 91 0.8516 180MC 21 39.7 249 91 0.8518 180L 25 45.5 307 93 0.8724 200LC 35 62.1 428 93 0.8628 225SC 43 78.3 466 93 0.8432 225MC 52 93.8 517 93 0.86

125JM/40/8/9/... 720 12 132S 2.5 5.8 26.2 82 0.7616 132M 3.5 8.7 44.4 84 0.6820 160M 4.6 10.2 54.5 86 0.7626 160M 6.3 13.6 73.1 87 0.7732 160L 8.6 18.2 106 88 0.7836 180L 13 25.7 164 90 0.79

125JM/40/6/9/... 960 12 132M 6.3 13.7 87.2 87 0.7716 160M 8.6 18 112 89 0.7822 160L 13 24.8 165 90 0.8228 180L 17 32.8 191 91 0.8432 200LC 21 39.8 261 92 0.8436 200LC 25 47.6 299 93 0.82

125JM/40/4/9/... 1470 10 180MC 21 39.7 249 91 0.8514 180L 25 45.5 307 93 0.8718 200LC 35 62.1 428 93 0.8622 225SC 43 78.3 466 93 0.8426 225MC 52 93.8 517 93 0.8630 250SC 63 113 782 94 0.8636 250MC 86 152 1020 94 0.87

125JM/50/4/6/... 1470 12 160L 17 32.1 226 91 0.8516 180MC 21 39.7 249 91 0.8518 180L 25 45.5 307 93 0.8724 200LC 35 62.1 428 93 0.8628 225SC 43 78.3 466 93 0.8432 225MC 52 93.8 517 93 0.86

125JM/50/4/9/... 1470 8 160L 17 32.1 226 91 0.8512 180MC 21 39.7 249 91 0.8514 180L 25 45.5 307 93 0.8720 200LC 35 62.1 428 93 0.8624 225SC 43 78.3 466 93 0.8426 225MC 52 93.8 517 93 0.8630 250SC 63 113 782 94 0.8636 250MC 86 152 1020 94 0.87

125JM/50/8/12/... 720 8 132S 2.5 5.8 26.2 82 0.7614 132M 3.5 8.7 44.4 84 0.6818 160M 4.6 10.2 54.5 86 0.7624 160M 6.3 13.6 73.1 87 0.7730 160L 8.6 18.2 106 88 0.7836 180L 13 25.7 164 90 0.79

JM AEROFOIL

Page 26: JM Aerofoil 50 Hz Technical

Motor Frame Size Schedules

380-420 V / 50 Hz / 3 φ

Speed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

125JM/50/6/12/... 960 8 132M 6.3 13.7 87.2 87 0.7712 160M 8.6 18 112 89 0.7820 160L 13 24.8 165 90 0.8224 180L 17 32.8 191 91 0.8430 200LC 21 39.8 261 92 0.8434 200LC 25 47.6 299 93 0.8236 225MC 35 64.9 384 92 0.83

125JM/50/4/12/... 1470 8 180MC 21 39.7 249 91 0.8510 180L 25 45.5 307 93 0.8716 200LC 35 62.1 428 93 0.8620 225SC 43 78.3 466 93 0.8422 225MC 52 93.8 517 93 0.8626 250SC 63 113 782 94 0.8634 250MC 86 152 1020 94 0.87

140JM/40/8/6/... 720 10 132S 2.5 5.8 26.2 82 0.7614 132M 3.5 8.7 44.4 84 0.6818 160M 4.6 10.2 54.5 86 0.7622 160M 6.3 13.6 73.1 87 0.7730 160L 8.6 18.2 106 88 0.7836 180L 13 25.7 164 90 0.79

140JM/40/6/6/... 960 10 132M 6.3 13.7 87.2 87 0.7714 160M 8.6 18 112 89 0.7820 160L 13 24.8 165 90 0.8224 180L 17 32.8 191 91 0.8430 200LC 21 39.8 261 92 0.8434 200LC 25 47.6 299 93 0.8236 225MC 35 64.9 384 92 0.83

140JM/40/8/9/... 720 12 160M 4.6 10.2 54.5 86 0.7618 160M 6.3 13.6 73.1 87 0.7724 160L 8.6 18.2 106 88 0.7832 180L 13 25.7 164 90 0.7936 200LC 17 35.6 192 89 0.78

140JM/40/6/9/... 960 14 160L 13 24.8 165 90 0.8220 180L 17 32.8 191 91 0.8424 200LC 21 39.8 261 92 0.8426 200LC 25 47.6 299 93 0.8234 225MC 35 64.9 384 92 0.8336 250SC 43 77.4 495 93 0.86

140JM/50/4/9/... 1470 8 180L 25 45.5 307 93 0.8712 200LC 35 62.1 428 93 0.8616 225SC 43 78.3 466 93 0.8418 225MC 52 93.8 517 93 0.8622 250SC 63 113 782 94 0.8628 250MC 86 152 1020 94 0.87

140JM/50/8/12/... 720 10 160M 4.6 10.2 54.5 86 0.7614 160M 6.3 13.6 73.1 87 0.7720 160L 8.6 18.2 106 88 0.7828 180L 13 25.7 164 90 0.7934 200LC 17 35.6 192 89 0.7836 225SC 21 42.7 190 92 0.79

140JM/50/6/12/... 960 12 160L 13 24.8 165 90 0.8216 180L 17 32.8 191 91 0.8420 200LC 21 39.8 261 92 0.8424 200LC 25 47.6 299 93 0.8230 225MC 35 64.9 384 92 0.8336 250SC 43 77.4 495 93 0.86

JM AEROFOIL

Page 27: JM Aerofoil 50 Hz Technical

JM AEROFOIL

Motor Frame Size Schedules

380-420 V / 50 Hz / 3 φ

Speed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

140JM/50/4/12/... 1470 8 200LC 35 62.1 428 93 0.8612 225SC 43 78.3 466 93 0.8414 225MC 52 93.8 517 93 0.8618 250SC 63 113 782 94 0.8624 250MC 86 152 1020 94 0.87

160JM/40/8/6/... 720 8 160M 4.6 10.2 54.5 86 0.7614 160M 6.3 13.6 73.1 87 0.7718 160L 8.6 18.2 106 88 0.7824 180L 13 25.7 164 90 0.7930 200LC 17 35.6 192 89 0.7832 225SC 21 42.7 190 92 0.79

160JM/40/6/6/... 960 10 160L 13 24.8 165 90 0.8216 180L 17 32.8 191 91 0.8418 200LC 21 39.8 261 92 0.8422 200LC 25 47.6 299 93 0.8226 225MC 35 64.9 384 92 0.8330 250SC 43 77.4 495 93 0.8632 250MC 52 95.4 601 93 0.84

160JM/40/8/9/... 720 8 160M 6.3 13.6 73.1 87 0.7714 160L 8.6 18.2 106 88 0.7820 180L 13 25.7 164 90 0.7924 200LC 17 35.6 192 89 0.7828 225SC 21 42.7 190 92 0.7932 225MC 25 52.8 269 92 0.7536 250SC 35 72.5 423 91 0.76

160JM/40/6/9/... 960 10 180L 17 32.8 191 91 0.8412 200LC 21 39.8 261 92 0.8416 200LC 25 47.6 299 93 0.8220 225MC 35 64.9 384 92 0.8324 250SC 43 77.4 495 93 0.8628 250MC 52 95.4 601 93 0.84

160JM/50/6/9/... 960 10 180L 17 32.8 191 91 0.8414 200LC 21 39.8 261 92 0.8416 200LC 25 47.6 299 93 0.8222 225MC 35 64.9 384 92 0.8326 250SC 43 77.4 495 93 0.8628 250MC 52 95.4 601 93 0.84

160JM/50/8/12/... 720 10 160L 8.6 18.2 106 88 0.7816 180L 13 25.7 164 90 0.7920 200LC 17 35.6 192 89 0.7824 225SC 21 42.7 190 92 0.7928 225MC 25 52.8 269 92 0.7536 250SC 35 72.5 423 91 0.76

160JM/50/6/12/... 960 10 200LC 21 39.8 261 92 0.8412 200LC 25 47.6 299 93 0.8218 225MC 35 64.9 384 92 0.8322 250SC 43 77.4 495 93 0.8624 250MC 52 95.4 601 93 0.84

Page 28: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules :Two Speed (Full and Half Pole Change)

30

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

31JM/16/6-12/5/... 900 40 CT5 0.21 470 0.026 0.85/0.3 1.7/0.45 44/19 0.81/0.67

31JM/16/4-8/5/... 1420 40 BT5 0.165 700 0.025 0.63/0.3 2/0.6 51/22 0.75/0.59

31JM/16/2-4/5/... 2840 16 BT5 0.25 1440 0.03 0.86/0.22 2.8/1.1 51/43 0.81/0.4626 BT9 0.44 1440 0.055 1.2/0.35 4.5/1.2 68/55 0.76/0.4140 CT5 0.8 1440 0.1 2.3/0.75 9/3 67/37 0.77/0.5

35JM/16/6-12/5/... 900 40 CT5 0.21 470 0.026 0.85/0.3 1.7/0.45 44/19 0.81/0.67

35JM/16/4-8/5/... 1420 40 BT5 0.165 700 0.025 0.63/0.3 2/0.6 51/22 0.75/0.59

35JM/16/2-4/5/... 2840 8 BT5 0.25 1440 0.03 0.86/0.22 2.8/1.1 51/43 0.81/0.4616 BT9 0.44 1440 0.055 1.2/0.35 4.5/1.2 68/55 0.76/0.4128 CT5 0.8 1440 0.1 2.3/0.75 9/3 67/37 0.77/0.540 CT9 1.4 1440 0.17 3.1/1.1 16.5/5 78/50 0.84/0.45

40JM/16/6-12/5/... 900 40 CT5 0.21 470 0.026 0.85/0.3 1.7/0.45 44/19 0.81/0.67

40JM/16/4-8/5/... 1420 26 BT5 0.165 700 0.025 0.63/0.3 2/0.6 51/22 0.75/0.5938 BT9 0.28 720 0.035 0.9/0.6 3/0.9 58/18 0.77/0.4840 CT5 0.5 700 0.06 1.28/0.5 3.7/1 71/31 0.79/0.56

40JM/16/2-4/5/... 2840 8 BT9 0.44 1440 0.055 1.2/0.35 4.5/1.2 68/55 0.76/0.4116 CT5 0.8 1440 0.1 2.3/0.75 9/3 67/37 0.77/0.526 CT9 1.4 1440 0.17 3.1/1.1 16.5/5 78/50 0.84/0.45

45JM/16/6-12/5/... 900 40 CT5 0.21 470 0.026 0.85/0.3 1.7/0.45 44/19 0.81/0.67

45JM/16/4-8/5/... 1420 16 BT5 0.165 700 0.025 0.63/0.3 2/0.6 51/22 0.75/0.5924 BT9 0.28 720 0.035 0.9/0.6 3/0.9 58/18 0.77/0.4838 CT5 0.5 700 0.06 1.28/0.5 3.7/1 71/31 0.79/0.5640 CT9 0.9 700 0.12 2.5/1.0 9/2.5 62/40 0.80/0.47

45JM/16/2-4/5/... 2840 10 CT5 0.8 1440 0.1 2.3/0.75 9/3 67/37 0.77/0.516 CT9 1.4 1440 0.17 3.1/1.1 16.5/5 78/50 0.84/0.45

45JM/20/6-12/3/... 900 36 CT5 0.21 470 0.026 0.85/0.3 1.7/0.45 44/19 0.81/0.67

45JM/20/4-8/3/... 1420 22 BT5 0.165 700 0.025 0.63/0.3 2/0.6 51/22 0.75/0.5934 BT9 0.28 720 0.035 0.9/0.6 3/0.9 58/18 0.77/0.4836 CT5 0.5 700 0.06 1.28/0.5 3.7/1 71/31 0.79/0.56

45JM/20/2-4/3/... 2910 8 BT9 0.44 1440 0.055 1.2/0.35 4.5/1.2 68/55 0.76/0.4116 CT5 0.8 1440 0.1 2.3/0.75 9/3 67/37 0.77/0.524 CT9 1.4 1440 0.17 3.1/1.1 16.5/5 78/50 0.84/0.4536 F2225 2.7 1440 0.34 5.5/2.5 32/9 79/49 0.90/0.41

45JM/20/6-12/6/... 900 40 CT5 0.21 470 0.026 0.85/0.3 1.7/0.45 44/19 0.81/0.67

45JM/20/4-8/6/... 1420 14 BT5 0.165 700 0.025 0.63/0.3 2/0.6 51/22 0.75/0.5924 BT9 0.28 720 0.035 0.9/0.6 3/0.9 58/18 0.77/0.4838 CT5 0.5 700 0.06 1.28/0.5 3.7/1 71/31 0.79/0.5640 CT9 0.9 700 0.12 2.5/1.0 9/2.5 62/40 0.80/0.47

45JM/20/2-4/6/... 2910 8 CT5 0.8 1440 0.1 2.3/0.75 9/3 67/37 0.77/0.516 CT9 1.4 1440 0.17 3.1/1.1 16.5/5 78/50 0.84/0.4526 F2225 2.7 1440 0.34 5.5/2.5 32/9 79/49 0.90/0.4140 PM112 5 1440 0.65 9.5/4.8 80/23 83/54 0.84/0.41

50JM/16/6-12/5/... 915 36 CT5 0.21 470 0.026 0.85/0.3 1.7/0.45 44/19 0.81/0.6740 CT9 0.41 470 0.05 1.6/0.7 2.8/0.9 53/20 0.7/0.54

Page 29: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules :Two Speed (Full and Half Pole Change)

31

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

50JM/16/4-8/5/... 1420 8 BT5 0.165 700 0.025 0.63/0.3 2/0.6 51/22 0.75/0.5916 BT9 0.28 720 0.035 0.9/0.6 3/0.9 58/18 0.77/0.4826 CT5 0.5 700 0.06 1.28/0.5 3.7/1 71/31 0.79/0.5640 CT9 0.9 700 0.12 2.5/1.0 9/2.5 62/40 0.80/0.47

50JM/20/6-12/3/... 915 36 CT5 0.21 470 0.026 0.85/0.3 1.7/0.45 44/19 0.81/0.67

50JM/20/4-8/3/... 1420 14 BT5 0.165 700 0.025 0.63/0.3 2/0.6 51/22 0.75/0.5924 BT9 0.28 720 0.035 0.9/0.6 3/0.9 58/18 0.77/0.4836 CT5 0.5 700 0.06 1.28/0.5 3.7/1 71/31 0.79/0.56

50JM/20/2-4/3/... 2910 10 CT5 0.8 1440 0.1 2.3/0.75 9/3 67/37 0.77/0.516 CT9 1.4 1440 0.17 3.1/1.1 16.5/5 78/50 0.84/0.4528 F2225 2.7 1440 0.34 5.5/2.5 32/9 79/49 0.90/0.4136 PM112 5 1440 0.65 9.5/4.8 80/23 83/54 0.84/0.41

50JM/20/6-12/6/... 915 34 CT5 0.21 470 0.026 0.85/0.3 1.7/0.45 44/19 0.81/0.6740 CT9 0.41 470 0.05 1.6/0.7 2.8/0.9 53/20 0.7/0.54

50JM/20/4-8/6/... 1420 14 BT9 0.28 720 0.035 0.9/0.6 3/0.9 58/18 0.77/0.4826 CT5 0.5 700 0.06 1.28/0.5 3.7/1 71/31 0.79/0.5640 CT9 0.9 700 0.12 2.5/1.0 9/2.5 62/40 0.80/0.47

50JM/20/2-4/6/... 2910 8 CT9 1.4 1440 0.17 3.1/1.1 16.5/5 78/50 0.84/0.4518 F2225 2.7 1440 0.34 5.5/2.5 32/9 79/49 0.90/0.4130 PM112 5 1440 0.65 9.5/4.8 80/23 83/54 0.84/0.41

56JM/16/6-12/5/... 900 24 CT5 0.21 470 0.026 0.85/0.3 1.7/0.45 44/19 0.81/0.6740 CT9 0.41 470 0.05 1.6/0.7 2.8/0.9 53/20 0.7/0.54

56JM/16/4-8/5/... 1420 8 BT9 0.28 720 0.035 0.9/0.6 3/0.9 58/18 0.77/0.4818 CT5 0.5 700 0.06 1.28/0.5 3.7/1 71/31 0.79/0.5628 CT9 0.9 700 0.12 2.5/1.0 9/2.5 62/40 0.80/0.47

56JM/20/6-12/3/... 900 34 CT5 0.21 470 0.026 0.85/0.3 1.7/0.45 44/19 0.81/0.6736 CT9 0.41 470 0.05 1.6/0.7 2.8/0.9 53/20 0.7/0.54

56JM/20/4-8/3/... 1420 8 BT5 0.165 700 0.025 0.63/0.3 2/0.6 51/22 0.75/0.5916 BT9 0.28 720 0.035 0.9/0.6 3/0.9 58/18 0.77/0.4826 CT5 0.5 700 0.06 1.28/0.5 3.7/1 71/31 0.79/0.5636 CT9 0.9 700 0.12 2.5/1.0 9/2.5 62/40 0.80/0.47

56JM/20/2-4/3/... 2910 10 CT9 1.4 1440 0.17 3.1/1.1 16.5/5 78/50 0.84/0.4518 F2225 2.7 1440 0.34 5.5/2.5 32/9 79/49 0.90/0.4130 PM112 5 1440 0.65 9.5/4.8 80/23 83/54 0.84/0.41

56JM/20/6-12/6/... 900 24 CT5 0.21 470 0.026 0.85/0.3 1.7/0.45 44/19 0.81/0.6738 CT9 0.41 470 0.05 1.6/0.7 2.8/0.9 53/20 0.7/0.5440 F2265 0.95 470 0.12 2.9/1.05 10/2.2 68/36 0.70/0.45

56JM/20/4-8/6/... 1420 16 CT5 0.5 700 0.06 1.28/0.5 3.7/1 71/31 0.79/0.5626 CT9 0.9 700 0.12 2.5/1.0 9/2.5 62/40 0.80/0.4740 F2265 1.8 720 0.23 4.2/1.8 35936 77/47 0.80/0.40

56JM/20/2-4/6/... 2910 10 F2225 2.7 1440 0.34 5.5/2.5 32/9 79/49 0.90/0.4120 PM112 5 1440 0.65 9.5/4.8 80/23 83/54 0.84/0.41

63JM/20/6-12/3/... 900 20 CT5 0.21 470 0.026 0.85/0.3 1.7/0.45 44/19 0.81/0.6732 CT9 0.41 470 0.05 1.6/0.7 2.8/0.9 53/20 0.7/0.5436 F2265 0.95 470 0.12 2.9/1.05 10/2.2 68/36 0.70/0.45

Page 30: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules :Two Speed (Full and Half Pole Change)

32

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

63JM/20/4-8/3/... 1420 12 CT5 0.5 700 0.06 1.28/0.5 3.7/1 71/31 0.79/0.5622 CT9 0.9 700 0.12 2.5/1.0 9/2.5 62/40 0.80/0.4736 F2265 1.8 720 0.23 4.2/1.8 21/5 77/47 0.80/0.40

63JM/20/6-12/6/... 900 10 CT5 0.21 470 0.026 0.85/0.3 1.7/0.45 44/19 0.81/0.6722 CT9 0.41 470 0.05 1.6/0.7 2.8/0.9 53/20 0.7/0.5436 F2265 0.95 470 0.12 2.9/1.05 10/2.2 68/36 0.70/0.45

63JM/20/4-8/6/... 1420 14 CT9 0.9 700 0.12 2.5/1.0 9/2.5 62/40 0.80/0.4726 F2265 1.8 720 0.23 4.2/1.8 21/5 77/47 0.80/0.4036 F2269 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.38

63JM/25/2-4/3/... 2910 12 F2225 2.7 1440 0.34 5.5/2.5 32/9 79/49 0.90/0.4118 PM112 5 1440 0.65 9.5/4.8 80/23 83/54 0.84/0.4118 D132/14 4.8 1480 0.6 9.5/2.4 56/16.5 80/68 0.91/0.5624 D132/19 7.15 1470 0.9 13.5/3.3 88/26 83/72 0.92/0.5632 D160/23 12 1480 1.49 21.8/5.9 175/50 89/78 0.89/0.47

63JM/25/4-8/6/... 1440 30 F2265 1.8 720 0.23 4.2/1.8 21/5 77/47 0.80/0.4036 F2269 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.38

63JM/25/2-4/6/... 2910 12 PM112 5 1440 0.65 9.5/4.8 80/23 83/54 0.84/0.4112 D132/14 4.8 1480 0.6 9.5/2.4 56/16.5 80/68 0.91/0.5616 D132/19 7.15 1470 0.9 13.5/3.3 88/26 83/72 0.92/0.5626 D160/23 12 1480 1.49 21.8/5.9 175/50 89/78 0.89/0.4732 D160/28 15.5 1480 1.94 28/7.7 224/65 90/79 0.90/0.4836 D160/32 19.4 1480 2.42 34.2/9.1 273/78 90/78 0.91/0.49

63JM/25/6-12/9/... 935 40 F2265 0.95 470 0.12 2.9/1.05 10/2.2 68/36 0.70/0.45

63JM/25/4-8/9/... 1440 26 F2265 1.8 720 0.23 4.2/1.8 21/5 77/47 0.80/0.4038 F2269 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.3840 D132/19 4.5 730 0.56 10.5/2.4 58/12.5 79/67 0.78/0.50

63JM/25/2-4/9/... 2910 8 PM112 5 1440 0.65 9.5/4.8 80/23 83/54 0.84/0.418 D132/14 4.8 1480 0.6 9.5/2.4 56/16.5 80/68 0.91/0.56

14 D132/19 7.15 1470 0.9 13.5/3.3 88/26 83/72 0.92/0.5622 D160/23 12 1480 1.49 21.8/5.9 175/50 89/78 0.89/0.4726 D160/28 15.5 1480 1.94 28/7.7 224/65 90/79 0.90/0.4832 D160/32 19.4 1480 2.42 34.2/9.1 273/78 90/78 0.91/0.49

71JM/20/6-12/3/... 900 10 CT5 0.21 470 0.026 0.85/0.3 1.7/0.45 44/19 0.81/0.6722 CT9 0.41 470 0.05 1.6/0.7 2.8/0.9 53/20 0.7/0.5436 F2265 0.95 470 0.12 2.9/1.05 10/2.2 68/36 0.70/0.45

71JM/20/4-8/3/... 1440 12 CT9 0.9 700 0.12 2.5/1.0 9/2.5 62/40 0.80/0.4726 F2265 1.8 720 0.23 4.2/1.8 21/5 77/47 0.80/0.4036 F2269 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.38

71JM/20/6-12/6/... 900 12 CT9 0.41 470 0.05 1.6/0.7 2.8/0.9 53/20 0.7/0.5428 F2265 0.95 470 0.12 2.9/1.05 10/2.2 68/36 0.70/0.4536 F2269 1.6 460 0.2 4.8/1.95 23/4.5 70/37 0.69/0.42

71JM/20/4-8/6/... 1440 16 F2265 1.8 720 0.23 4.2/1.8 21/5 77/47 0.80/0.4026 F2269 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.38

71JM/25/4-8/3/... 1440 30 F2265 1.8 720 0.23 4.2/1.8 21/5 77/47 0.80/0.4032 F2269 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.38

71JM/25/6-12/6/... 935 34 F2265 0.95 470 0.12 2.9/1.05 10/2.2 68/36 0.70/0.4536 F2269 1.6 460 0.2 4.8/1.95 23/4.5 70/37 0.69/0.42

Page 31: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules :Two Speed (Full and Half Pole Change)

33

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

71JM/25/4-8/6/... 1440 20 F2265 1.8 720 0.23 4.2/1.8 21/5 77/47 0.80/0.4030 F2269 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.3836 D132/19 4.5 730 0.56 10.5/2.4 58/12.5 79/67 0.78/0.50

71JM/25/6-12/9/... 935 26 F2265 0.95 470 0.12 2.9/1.05 10/2.2 68/36 0.70/0.4536 F2269 1.6 460 0.2 4.8/1.95 23/4.5 70/37 0.69/0.42

71JM/25/4-8/9/... 1440 12 F2265 1.8 720 0.23 4.2/1.8 21/5 77/47 0.80/0.4024 F2269 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.3832 D132/19 4.5 730 0.56 10.5/2.4 58/12.5 79/67 0.78/0.5036 D132/26 6.3 730 0.82 14.5/3.5 87/19 81/69 0.76/0.50

71JM/31/2-4/9/... 2910 12 D160/23 12 1480 1.49 21.8/5.9 175/50 89/78 0.89/0.4716 D160/28 15.5 1480 1.94 28/7.7 224/65 90/79 0.90/0.4820 D160/32 19.4 1480 2.42 34.2/9.1 273/78 90/78 0.91/0.4922 D180/31 23.9 1480 2.98 42.5/8.8 255/71 90/82 0.91/0.61

80JM/20/6-12/3/... 935 14 CT9 0.41 470 0.05 1.6/0.7 2.8/0.9 53/20 0.7/0.5428 F2265 0.95 470 0.12 2.9/1.05 10/2.2 68/36 0.70/0.4536 F2269 1.6 460 0.2 4.8/1.95 23/4.5 70/37 0.69/0.42

80JM/20/4-8/3/... 1440 18 F2265 1.8 720 0.23 4.2/1.8 21/5 77/47 0.80/0.4026 F2269 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.38

80JM/20/6-12/6/... 935 18 F2265 0.95 470 0.12 2.9/1.05 10/2.2 68/36 0.70/0.4530 F2269 1.6 460 0.2 4.8/1.95 23/4.5 70/37 0.69/0.42

80JM/20/4-8/6/... 1440 8 F2265 1.8 720 0.23 4.2/1.8 21/5 77/47 0.80/0.4016 F2269 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.38

80JM/25/6-12/3/... 935 32 F2265 0.95 470 0.12 2.9/1.05 10/2.2 68/36 0.70/0.45

80JM/25/4-8/3/... 1440 20 F2265 1.8 720 0.23 4.2/1.8 21/5 77/47 0.80/0.4032 F2269 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.38

80JM/25/6-12/6/... 935 22 F2265 0.95 470 0.12 2.9/1.05 10/2.2 68/36 0.70/0.4534 F2269 1.6 460 0.2 4.8/1.95 23/4.5 70/37 0.69/0.4236 D132/19 3.3 480 0.41 10.2/2.7 52/9.5 73/55 0.64/0.40

80JM/25/4-8/6/... 1440 12 F2265 1.8 720 0.23 4.2/1.8 21/5 77/47 0.80/0.4020 F2269 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.3828 D132/19 4.5 730 0.56 10.5/2.4 58/12.5 79/67 0.78/0.5034 D132/26 6.3 730 0.82 14.5/3.5 87/19 81/69 0.76/0.5036 D160/23 9.7 740 1.19 18.5/5.5 145/33 87/74 0.86/0.46

80JM/25/6-12/9/... 935 16 F2265 0.95 470 0.12 2.9/1.05 10/2.2 68/36 0.70/0.4528 F2269 1.6 460 0.2 4.8/1.95 23/4.5 70/37 0.69/0.4236 D132/19 3.3 480 0.41 10.2/2.7 52/9.5 73/55 0.64/0.40

80JM/25/4-8/9/... 1440 14 F2269 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.3822 D132/19 4.5 730 0.56 10.5/2.4 58/12.5 79/67 0.78/0.5028 D132/26 6.3 730 0.82 14.5/3.5 87/19 81/69 0.76/0.5036 D160/23 9.7 740 1.19 18.5/5.5 145/33 87/74 0.86/0.46

80JM/31/2-4/9/... 2910 8 D160/28 15.5 1480 1.94 28/7.7 224/65 90/79 0.90/0.4812 D160/32 19.4 1480 2.42 34.2/9.1 273/78 90/78 0.91/0.4914 D180/31 23.9 1480 2.98 42.5/8.8 255/71 90/82 0.91/0.61

90JM/25/6-12/3/... 935 22 F2265 0.95 470 0.12 2.9/1.05 10/2.2 68/36 0.70/0.4532 F2269 1.6 460 0.2 4.8/1.95 23/4.5 70/37 0.69/0.42

Page 32: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules :Two Speed (Full and Half Pole Change)

34

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

90JM/25/4-8/3/... 1440 12 F2265 1.8 720 0.23 4.2/1.8 21/5 77/47 0.80/0.4022 F2269 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.3828 D132/19 4.5 730 0.56 10.5/2.4 58/12.5 79/67 0.78/0.5032 D132/26 6.3 730 0.82 14.5/3.5 87/19 81/69 0.76/0.50

90JM/25/6-12/6/... 935 14 F2265 0.95 470 0.12 2.9/1.05 10/2.2 68/36 0.70/0.4524 F2269 1.6 460 0.2 4.8/1.95 23/4.5 70/37 0.69/0.4232 D132/19 3.3 480 0.41 10.2/2.7 52/9.5 73/55 0.64/0.40

90JM/25/4-8/6/... 1440 12 F2265 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.3818 D132/19 4.5 730 0.56 10.5/2.4 58/12.5 79/67 0.78/0.5024 D132/26 6.3 730 0.82 14.5/3.5 87/19 81/69 0.76/0.5032 D160/23 9.7 740 1.19 18.5/5.5 145/33 87/74 0.86/0.46

90JM/25/6-12/9/... 935 16 F2269 1.6 460 0.2 4.8/1.95 23/4.5 70/37 0.69/0.4228 D132/19 3.3 480 0.41 10.2/2.7 52/9.5 73/55 0.64/0.4036 D132/26 4.7 480 0.56 11.5/2.8 61/10 77/62 0.77/0.47

90JM/25/4-8/9/... 1440 10 D132/19 4.5 730 0.56 10.5/2.4 58/12.5 79/67 0.78/0.5016 D132/26 6.3 730 0.82 14.5/3.5 87/19 81/69 0.76/0.5024 D160/23 9.7 740 1.19 18.5/5.5 145/33 87/74 0.86/0.4632 D160/30 13.4 730 1.68 26.8/8.8 208/47 87/72 0.82/0.38

100JM/25/6-12/3/... 935 16 F2265 0.95 470 0.12 2.9/1.05 10/2.2 68/36 0.70/0.4526 F2269 1.6 460 0.2 4.8/1.95 23/4.5 70/37 0.69/0.4232 D132/19 3.3 480 0.41 10.2/2.7 52/9.5 73/55 0.64/0.40

100JM/25/4-8/3/... 1440 14 F2269 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.3820 D132/19 4.5 730 0.56 10.5/2.4 58/12.5 79/67 0.78/0.5026 D132/26 6.3 730 0.82 14.5/3.5 87/19 81/69 0.76/0.5032 D160/23 9.7 740 1.19 18.5/5.5 145/33 87/74 0.86/0.46

100JM/25/6-12/6/... 950 16 F2269 1.6 460 0.2 4.8/1.95 23/4.5 70/37 0.69/0.4226 D132/19 3.3 480 0.41 10.2/2.7 52/9.5 73/55 0.64/0.4032 D132/26 4.7 480 0.56 11.5/2.8 61/10 77/62 0.77/0.47

100JM/25/4-8/6/... 1450 10 D132/19 4.5 730 0.56 10.5/2.4 58/12.5 79/67 0.78/0.5016 D132/26 6.3 730 0.82 14.5/3.5 87/19 81/69 0.76/0.5024 D160/23 9.7 740 1.19 18.5/5.5 145/33 87/74 0.86/0.4630 D160/30 13.4 730 1.68 26.8/8.8 208/47 87/72 0.82/0.38

100JM/25/6-12/9/... 960 10 F2269 1.6 460 0.2 4.8/1.95 23/4.5 70/37 0.69/0.4218 D132/19 3.3 480 0.41 10.2/2.7 52/9.5 73/55 0.64/0.4026 D132/26 4.7 480 0.56 11.5/2.8 61/10 77/62 0.77/0.4736 D160/27 7.46 490 0.93 17.3/4.8 91/17.5 82/64 0.76/0.44

100JM/25/4-8/9/... 1470 10 D132/26 6.3 730 0.82 14.5/3.5 87/19 81/69 0.76/0.5016 D160/23 9.7 740 1.19 18.5/5.5 145/33 87/74 0.86/0.4622 D160/30 13.4 730 1.68 26.8/8.8 208/47 87/72 0.82/0.38

100JM/31/4-8/9/... 1470 10 D132/26 6.3 730 0.82 14.5/3.5 87/19 81/69 0.76/0.5016 D160/23 9.7 740 1.19 18.5/5.5 145/33 87/74 0.86/0.4622 D160/30 13.4 730 1.68 26.8/8.8 208/47 87/72 0.82/0.3826 D180/29 15.7 730 1.94 29.9/5.7 210/35 89/82 0.85/0.6030 D180/35 20.1 735 2.54 38/10.9 266/60 90/78 0.86/0.43

100JM/40/4-8/9/... 1470 12 D160/23 9.7 740 1.19 18.5/5.5 145/33 87/74 0.86/0.4620 D160/30 13.4 730 1.68 26.8/8.8 208/47 87/72 0.82/0.3822 D180/29 15.7 730 1.94 29.9/5.7 210/35 89/82 0.85/0.6026 D180/35 20.1 735 2.54 38/10.9 266/60 90/78 0.86/0.4330 D200/36 23.9 735 2.98 46/13.5 330/61 90/80 0.83/0.4038 D200/46 32.8 735 4.1 62/18.5 450/96 91/81 0.84/0.4040 W200/LFR 37 730 7 69/22 448/110 91.5/85 0.85/0.54

Page 33: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules :Two Speed (Full and Half Pole Change)

35

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

112JM/40/6-12/6/... 960 12 D132/19 3.3 480 0.41 10.2/2.7 52/9.5 73/55 0.64/0.4020 D132/26 4.7 480 0.56 11.5/2.8 61/10 77/62 0.77/0.4726 D160/27 7.46 490 0.93 17.3/4.8 91/17.5 82/64 0.76/0.4432 D160/34 11.2 480 1.42 25.5/7 135/26 83/65 0.77/0.45

112JM/40/4-8/6/... 1470 10 D160/23 9.7 740 1.19 18.5/5.5 145/33 87/74 0.86/0.4616 D160/30 13.4 730 1.68 26.8/8.8 208/47 87/72 0.82/0.3818 D180/29 15.7 730 1.94 29.9/5.7 210/35 89/82 0.85/0.6022 D180/35 20.1 735 2.54 38/10.9 266/60 90/78 0.86/0.4326 D200/36 23.9 735 2.98 46/13.5 330/61 90/80 0.83/0.4032 D200/46 32.8 735 4.1 62/18.5 450/96 91/81 0.84/0.40

112JM/40/6-12/9/... 960 8 D132/19 3.3 480 0.41 10.2/2.7 52/9.5 73/55 0.64/0.4014 D132/26 4.7 480 0.56 11.5/2.8 61/10 77/62 0.77/0.4722 D160/27 7.46 490 0.93 17.3/4.8 91/17.5 82/64 0.76/0.4430 D160/34 11.2 480 1.42 25.5/7 135/26 83/65 0.77/0.4536 D180/35 16.4 490 2.05 35/9.1 228.38 85/71 0.79/0.46

112JM/40/4-8/9/... 1470 10 D160/30 13.4 730 1.68 26.8/8.8 208/47 87/72 0.82/0.3814 D180/29 15.7 730 1.94 29.9/5.7 210/35 89/82 0.85/0.6018 D180/35 20.1 735 2.54 38/10.9 266/60 90/78 0.86/0.4320 D200/36 23.9 735 2.98 46/13.5 330/61 90/80 0.83/0.4026 D200/46 32.8 735 4.1 62/18.5 450/96 91/81 0.84/0.4028 W200/LFR 37 730 7 69/22 448/110 91.5/85 0.85/0.5434 W225/M 45 730 9 83/25 581/125 92/86 0.85/0.6136 W225/MF 55 730 11 101/29 707/145 92.5/88 0.85/0.62

112JM/50/6-12/12/... 960 12 D132/26 4.7 480 0.56 11.5/2.8 61/10 77/62 0.77/0.4720 D160/27 7.46 490 0.93 17.3/4.8 91/17.5 82/64 0.76/0.4428 D160/34 11.2 480 1.42 25.5/7 135/26 83/65 0.77/0.4536 D180/35 16.4 490 2.05 35/9.1 228.38 85/71 0.79/0.46

112JM/50/4-8/12/... 1470 8 D160/30 13.4 730 1.68 26.8/8.8 208/47 87/72 0.82/0.3812 D180/29 15.7 730 1.94 29.9/5.7 210/35 89/82 0.85/0.6016 D180/35 20.1 735 2.54 38/10.9 266/60 90/78 0.86/0.4320 D200/36 23.9 735 2.98 46/13.5 330/61 90/80 0.83/0.4024 D200/46 32.8 735 4.1 62/18.5 450/96 91/81 0.84/0.4026 W200/LFR 37 730 7 69/22 448/110 91.5/85 0.85/0.5432 W225/M 45 730 9 83/25 581/125 92/86 0.85/0.6136 W225/MF 55 730 11 101/29 707/145 92.5/88 0.85/0.62

125JM/40/6-12/6/... 960 8 D132/19 3.3 480 0.41 10.2/2.7 52/9.5 73/55 0.64/0.4012 D132/26 4.7 480 0.56 11.5/2.8 61/10 77/62 0.77/0.4718 D160/27 7.46 490 0.93 17.3/4.8 91/17.5 82/64 0.76/0.4426 D160/34 11.2 480 1.42 25.5/7 135/26 83/65 0.77/0.4532 D180/35 16.4 490 2.05 35/9.1 228.38 85/71 0.79/0.46

125JM/40/4-8/6/... 1470 10 D160/30 13.4 730 1.68 26.8/8.8 208/47 87/72 0.82/0.3812 D180/29 15.7 730 1.94 29.9/5.7 210/35 89/82 0.85/0.6016 D180/35 20.1 735 2.54 38/10.9 266/60 90/78 0.86/0.4318 D200/36 23.9 735 2.98 46/13.5 330/61 90/80 0.83/0.4022 D200/46 32.8 735 4.1 62/18.5 450/96 91/81 0.84/0.4024 W200/LFR 37 730 7 69/22 448/110 91.5/85 0.85/0.5428 W225/M 45 730 9 83/25 581/125 92/86 0.85/0.6132 W225/MF 55 730 11 101/29 707/145 92.5/88 0.85/0.62

125JM/40/6-12/9/... 960 8 D132/26 4.7 480 0.56 11.5/2.8 61/10 77/62 0.77/0.4714 D160/27 7.46 490 0.93 17.3/4.8 91/17.5 82/64 0.76/0.4420 D160/34 11.2 480 1.42 25.5/7 135/26 83/65 0.77/0.4528 D180/35 16.4 490 2.05 35/9.1 228.38 85/71 0.79/0.4632 D200/38 20.5 490 2.54 45/13 272/55 86/71 0.76/0.4034 D200/46 23.1 490 2.91 51/15 308/63 86/71 0.76/0.4036 W200/LFR 24 475 5 46/17 345/85 89/81 0.88/0.53

Page 34: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules :Two Speed (Full and Half Pole Change)

36

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

125JM/40/4-8/9/... 1470 10 D180/35 20.1 735 2.54 38/10.9 266/60 90/78 0.86/0.4312 D200/36 23.9 735 2.98 46/13.5 330/61 90/80 0.83/0.4018 D200/46 32.8 735 4.1 62/18.5 450/96 91/81 0.84/0.4020 W200/LFR 37 730 7 69/22 448/110 91.5/85 0.85/0.5422 W225/M 45 730 9 83/25 581/125 92/86 0.85/0.6126 W225/MF 55 730 11 101/29 707/145 92.5/88 0.85/0.6232 W250/M 75 735 15 137/41 1027/205 93.2/89 0.85/0.636 W250/MF 90 735 18 162/48 1215/240 93.5/89.5 0.86/0.61

125JM/50/4-8/6/... 1470 10 D160/30 13.4 730 1.68 26.8/8.8 208/47 87/72 0.82/0.3812 D180/29 15.7 730 1.94 29.9/5.7 210/35 89/82 0.85/0.6014 D180/35 20.1 735 2.54 38/10.9 266/60 90/78 0.86/0.4318 D200/36 23.9 735 2.98 46/13.5 330/61 90/80 0.83/0.4022 D200/46 32.8 735 4.1 62/18.5 450/96 91/81 0.84/0.4024 W200/LFR 37 730 7 69/22 448/110 91.5/85 0.85/0.5428 W225/M 45 730 9 83/25 581/125 92/86 0.85/0.6132 W225/MF 55 730 11 101/29 707/145 92.5/88 0.85/0.62

125JM/50/4-8/9/... 1470 10 D180/35 20.1 735 2.54 38/10.9 266/60 90/78 0.86/0.4314 D200/36 23.9 735 2.98 46/13.5 330/61 90/80 0.83/0.4018 D200/46 32.8 735 4.1 62/18.5 450/96 91/81 0.84/0.4020 W200/LFR 37 730 7 69/22 448/110 91.5/85 0.85/0.5424 W225/M 45 730 9 83/25 581/125 92/86 0.85/0.6128 W225/MF 55 730 11 101/29 707/145 92.5/88 0.85/0.6234 W250/M 75 735 15 137/41 1027/205 93.2/89 0.85/0.636 W250/MF 90 735 18 162/48 1215/240 93.5/89.5 0.86/0.61

125JM/50/6-12/12/... 960 10 D160/27 7.46 490 0.93 17.3/4.8 91/17.5 82/64 0.76/0.4418 D160/34 11.2 480 1.42 25.5/7 135/26 83/65 0.77/0.4524 D180/35 16.4 490 2.05 35/9.1 228.38 85/71 0.79/0.4628 D200/38 20.5 490 2.54 45/13 272/55 86/71 0.76/0.4032 D200/46 23.1 490 2.91 51/15 308/63 86/71 0.76/0.4034 W200/LFR 24 475 5 46/17 345/85 89/81 0.88/0.5336 W225/M 30 485 6 57/20 400/100 89.5/82 0.85/0.52

125JM/50/4-8/12/... 1470 10 D200/36 23.9 735 2.98 46/13.5 330/61 90/80 0.83/0.4016 D200/46 32.8 735 4.1 62/18.5 450/96 91/81 0.84/0.4016 W200/LFR 37 730 7 69/22 448/110 91.5/85 0.85/0.5420 W225/M 45 730 9 83/25 581/125 92/86 0.85/0.6124 W225/MF 55 730 11 101/29 707/145 92.5/88 0.85/0.6230 W250/M 75 735 15 137/41 1027/205 93.2/89 0.85/0.634 W250/MF 90 735 18 162/48 1215/240 93.5/89.5 0.86/0.61

140JM/40/6-12/6/... 960 12 D160/27 7.46 490 0.93 17.3/4.8 91/17.5 82/64 0.76/0.4418 D160/34 11.2 480 1.42 25.5/7 135/26 83/65 0.77/0.4524 D180/35 16.4 490 2.05 35/9.1 228.38 85/71 0.79/0.4628 D200/38 20.5 490 2.54 45/13 272/55 86/71 0.76/0.4032 D200/46 23.1 490 2.91 51/15 308/63 86/71 0.76/0.4034 W200/LFR 24 475 5 46/17 345/85 89/81 0.88/0.5336 W225/M 30 485 6 57/20 400/100 89.5/82 0.85/0.52

140JM/50/6-12/9/... 960 8 D160/27 7.46 490 0.93 17.3/4.8 91/17.5 82/64 0.76/0.4414 D160/34 11.2 480 1.42 25.5/7 135/26 83/65 0.77/0.4520 D180/35 16.4 490 2.05 35/9.1 228.38 85/71 0.79/0.4624 D200/38 20.5 490 2.54 45/13 272/55 86/71 0.76/0.4026 D200/46 23.1 490 2.91 51/15 308/63 86/71 0.76/0.4028 W200/LFR 24 475 5 46/17 345/85 89/81 0.88/0.5332 W225/M 30 485 6 57/20 400/100 89.5/82 0.85/0.5236 W225/MF 37 485 7.4 70/25 490/125 89.5/82 0.85/0.5

Page 35: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules :Two Speed (Full and Half Pole Change)

37

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

140JM/50/4-8/9/... 1470 10 D200/46 32.8 735 4.1 62/18.5 450/96 91/81 0.84/0.4012 W200/LFR 37 730 7 69/22 448/110 91.5/85 0.85/0.5416 W225/M 45 730 9 83/25 581/125 92/86 0.85/0.6120 W225/MF 55 730 11 101/29 707/145 92.5/88 0.85/0.6224 W250/M 75 735 15 137/41 1027/205 93.2/89 0.85/0.628 W250/MF 90 735 18 162/48 1215/240 93.5/89.5 0.86/0.61

140JM/50/6-12/12/... 960 10 D160/34 11.2 480 1.42 25.5/7 135/26 83/65 0.77/0.4516 D180/35 16.4 490 2.05 35/9.1 228.38 85/71 0.79/0.4620 D200/38 20.5 490 2.54 45/13 272/55 86/71 0.76/0.4022 D200/46 23.1 490 2.91 51/15 308/63 86/71 0.76/0.4024 W200/LFR 24 475 5 46/17 345/85 89/81 0.88/0.5328 W225/M 30 485 6 57/20 400/100 89.5/82 0.85/0.5232 W225/MF 37 485 7.4 70/25 490/125 89.5/82 0.85/0.5236 W250/M 45 485 9 83/27 623/135 91.5/85.5 0.86/0.56

140JM/50/4-8/12/... 1470 8 D200/46 32.8 735 4.1 62/18.5 450/96 91/81 0.84/0.4010 W200/LFR 37 730 7 69/22 448/110 91.5/85 0.85/0.5412 W225/M 45 730 9 83/25 581/125 92/86 0.85/0.6116 W225/MF 55 730 11 101/29 707/145 92.5/88 0.85/0.6220 W250/M 75 735 15 137/41 1027/205 93.2/89 0.85/0.624 W250/MF 90 735 18 162/48 1215/240 93.5/89.5 0.86/0.61

160JM/40/6-12/6/... 960 10 D160/34 11.2 480 1.42 25.5/7 135/26 83/65 0.77/0.4514 D180/35 16.4 490 2.05 35/9.1 228.38 85/71 0.79/0.4618 D200/38 20.5 490 2.54 45/13 272/55 86/71 0.76/0.4020 D200/46 23.1 490 2.91 51/15 308/63 86/71 0.76/0.4022 W200/LFR 24 475 5 46/17 345/85 89/81 0.88/0.5324 W225/M 30 485 6 57/20 400/100 89.5/82 0.85/0.5228 W225/MF 37 485 7.4 70/25 490/125 89.5/82 0.85/0.5232 W250/M 45 485 9 83/27 623/135 91.5/85.5 0.86/0.56

160JM/40/6-12/9/... 960 10 D180/35 16.4 490 2.05 35/9.1 228.38 85/71 0.79/0.4612 D200/38 20.5 490 2.54 45/13 272/55 86/71 0.76/0.4014 D200/46 23.1 490 2.91 51/15 308/63 86/71 0.76/0.4016 W200/LFR 24 475 5 46/17 345/85 89/81 0.88/0.5318 W225/M 30 485 6 57/20 400/100 89.5/82 0.85/0.5222 W225/MF 37 485 7.4 70/25 490/125 89.5/82 0.85/0.5226 W250/M 45 485 9 83/27 623/135 91.5/85.5 0.86/0.5630 W250/MF 55 490 11 100/33 750/165 92.1/86.2 0.86/0.56

160JM/50/6-12/9/... 960 10 D180/35 16.4 490 2.05 35/9.1 228.38 85/71 0.79/0.4612 D200/38 20.5 490 2.54 45/13 272/55 86/71 0.76/0.4014 D200/46 23.1 490 2.91 51/15 308/63 86/71 0.76/0.4016 W200/LFR 24 475 5 46/17 345/85 89/81 0.88/0.5320 W225/M 30 485 6 57/20 400/100 89.5/82 0.85/0.5222 W225/MF 37 485 7.4 70/25 490/125 89.5/82 0.85/0.5226 W250/M 45 485 9 83/27 623/135 91.5/85.5 0.86/0.5630 W250/MF 55 490 11 100/33 750/165 92.1/86.2 0.86/0.56

160JM/50/6-12/12/... 960 10 D200/38 20.5 490 2.54 45/13 272/55 86/71 0.76/0.4010 D200/46 23.1 490 2.91 51/15 308/63 86/71 0.76/0.4012 W200/LFR 24 475 5 46/17 345/85 89/81 0.88/0.5316 W225/M 30 485 6 57/20 400/100 89.5/82 0.85/0.5220 W225/MF 37 485 7.4 70/25 490/125 89.5/82 0.85/0.5222 W250/M 45 485 9 83/27 623/135 91.5/85.5 0.86/0.5626 W250/MF 55 490 11 100/33 750/165 92.1/86.2 0.86/0.56

Page 36: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules:Two Speed (Full and Half Dual Wound)

38

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

45JM/20/6-12/3/... 900 36 F2265 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.53

45JM/20/4-8/3/... 1420 36 F2265 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.65

45JM/20/2-4/3/... 2910 32 F2245 2.15 1440 0.27 4.9/0.9 29/3.2 74/60 0.85/0.7736 PM112 3.7 1440 0.46 8.5/1.4 50/6.7 74/61 0.85/0.76

45JM/20/6-12/6/... 900 40 F2265 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.53

45JM/20/4-8/6/... 1420 40 F2265 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.65

45JM/20/2-4/6/... 2910 22 F2245 2.15 1440 0.27 4.9/0.9 29/3.2 74/60 0.85/0.7734 PM112 3.7 1440 0.46 8.5/1.4 50/6.7 74/61 0.85/0.76

50JM/20/6-12/3/... 915 36 F2265 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.53

50JM/20/4-8/3/... 1420 36 F2265 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.65

50JM/20/2-4/3/... 2910 24 F2245 2.15 1440 0.27 4.9/0.9 29/3.2 74/60 0.85/0.7734 PM112 3.7 1440 0.46 8.5/1.4 50/6.7 74/61 0.85/0.76

50JM/20/6-12/6/... 915 40 F2265 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.53

50JM/20/4-8/6/... 1420 40 F2265 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.65

50JM/20/2-4/6/... 2910 14 F2245 2.15 1440 0.27 4.9/0.9 29/3.2 74/60 0.85/0.7724 PM112 3.7 1440 0.46 8.5/1.4 50/6.7 74/61 0.85/0.76

56JM/20/6-12/3/... 900 36 F2265 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.53

56JM/20/4-8/3/... 1420 36 F2265 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.65

56JM/20/2-4/3/... 2910 16 F2245 2.15 1440 0.27 4.9/0.9 29/3.2 74/60 0.85/0.7724 PM112 3.7 1440 0.46 8.5/1.4 50/6.7 74/61 0.85/0.76

56JM/20/6-12/6/... 900 40 F2265 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.53

56JM/20/4-8/6/... 1420 40 F2265 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.65

56JM/20/2-4/6/... 2910 8 F2245 2.15 1440 0.27 4.9/0.9 29/3.2 74/60 0.85/0.7714 PM112 3.7 1440 0.46 8.5/1.4 50/6.7 74/61 0.85/0.76

63JM/20/6-12/3/... 900 36 F2265 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.53

63JM/20/4-8/3/... 1420 34 F2265 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.6536 F2269 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.65

63JM/20/6-12/6/... 900 36 F2265 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.53

63JM/20/4-8/6/... 1420 24 F2265 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.6536 F2269 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.65

63JM/25/2-4/3/... 2910 10 F2245 2.15 1440 0.27 4.9/0.9 29/3.2 74/60 0.85/0.7716 PM112 3.7 1440 0.46 8.5/1.4 50/6.7 74/61 0.85/0.7616 D132/14 4.1 1400 0.51 7.7/2.1 48/12 82/59 0.80/0.5622 D132/19 6 1460 0.75 11.6/2.2 81/15 82/69 0.91/0.7230 D160/23 9.3 1470 1.19 17.6/3.4 155/27 88/72 0.87/0.6932 D160/28 12 1480 1.49 21.8/4.2 196/33 89/73 0.88/0.70

63JM/25/4-8/6/... 1440 28 F2265 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.6536 F2269 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.65

Page 37: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules:Two Speed (Full and Half Dual Wound)

39

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

63JM/25/2-4/6/... 2910 8 PM112 3.7 1440 0.46 8.5/1.4 50/6.7 74/61 0.85/0.7610 D132/14 4.1 1400 0.51 7.7/2.1 48/12 82/59 0.80/0.5614 D132/19 6 1460 0.75 11.6/2.2 81/15 82/69 0.91/0.7220 D160/23 9.3 1470 1.19 17.6/3.4 155/27 88/72 0.87/0.6926 D160/28 12 1480 1.49 21.8/4.2 196/33 89/73 0.88/0.7030 D160/32 14.9 1480 1.86 27.5/5.2 248/42 89/73 0.88/0.70

63JM/25/6-12/9/... 935 36 F2265 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.5340 F2269 1.3 460 0.15 4/1.4 14/2.4 68/25 0.70/0.63

63JM/25/4-8/9/... 1440 24 F2265 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.6534 F2269 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.6540 D132/19 4.1 725 0.51 9.5/2.2 55/9 79/54 0.79/0.64

63JM/25/2-4/9/... 2910 10 D132/19 6 1460 0.75 11.6/2.2 81/15 82/69 0.91/0.7216 D160/23 9.3 1470 1.19 17.6/3.4 155/27 88/72 0.87/0.6920 D160/28 12 1480 1.49 21.8/4.2 196/33 89/73 0.88/0.7024 D160/32 14.9 1480 1.86 27.5/5.2 248/42 89/73 0.88/0.70

71JM/20/6-12/3/... 900 36 F2265 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.53

71JM/20/4-8/3/... 1440 24 F2265 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.6534 F2269 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.65

71JM/20/6-12/6/... 900 24 F2265 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.5336 F2269 1.3 460 0.15 4/1.4 14/2.4 68/25 0.70/0.63

71JM/20/4-8/6/... 1440 14 F2265 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.6524 F2269 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.65

71JM/25/4-8/3/... 1440 28 F2265 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.6532 F2269 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.65

71JM/25/6-12/6/... 935 28 F2265 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.5336 F2269 1.3 460 0.15 4/1.4 14/2.4 68/25 0.70/0.63

71JM/25/4-8/6/... 1440 18 F2265 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.6528 F2269 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.6536 D132/19 4.1 725 0.51 9.5/2.2 55/9 79/54 0.79/0.64

71JM/25/6-12/9/... 935 22 F2265 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.5334 F2269 1.3 460 0.15 4/1.4 14/2.4 68/25 0.70/0.6336 D132/19 3 480 0.37 8.4/2.3 50/6.5 75/39 0.69/0.60

71JM/25/4-8/9/... 1440 10 F2265 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.6520 F2269 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.6530 D132/19 4.1 725 0.51 9.5/2.2 55/9 79/54 0.79/0.6436 D132/26 5.6 730 0.7 11.5/3.2 69/13.5 81/51 0.87/0.62

71JM/31/2-4/9/... 2910 8 D160/23 9.3 1470 1.19 17.6/3.4 155/27 88/72 0.87/0.6910 D160/28 12 1480 1.49 21.8/4.2 196/33 89/73 0.88/0.7014 D160/32 14.9 1480 1.86 27.5/5.2 248/42 89/73 0.88/0.7016 D180/31 17.9 1480 2.24 33/6.6 249/53 89/77 0.87/0.63

80JM/20/6-12/3/... 935 24 F2265 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.5336 F2269 1.3 460 0.15 4/1.4 14/2.4 68/25 0.70/0.63

80JM/20/4-8/3/... 1440 16 F2265 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.6524 F2269 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.65

80JM/20/6-12/6/... 935 14 F2265 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.5324 F2269 1.3 460 0.15 4/1.4 14/2.4 68/25 0.70/0.63

Page 38: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules:Two Speed (Full and Half Dual Wound)

40

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

80JM/20/4-8/6/... 1440 14 F2269 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.65

80JM/25/6-12/3/... 935 28 F2265 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.5332 F2269 1.3 460 0.15 4/1.4 14/2.4 68/25 0.70/0.63

80JM/25/4-8/3/... 1440 18 F2265 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.6528 F2269 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.6532 D132/19 4.1 725 0.51 9.5/2.2 55/9 79/54 0.79/0.64

80JM/25/6-12/6/... 935 18 F2265 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.5328 F2269 1.3 460 0.15 4/1.4 14/2.4 68/25 0.70/0.6336 D132/19 3 480 0.37 8.4/2.3 50/6.5 75/39 0.69/0.60

80JM/25/4-8/6/... 1440 10 F2265 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.6518 F2269 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.6526 D132/19 4.1 725 0.51 9.5/2.2 55/9 79/54 0.79/0.6432 D132/26 5.6 730 0.7 11.5/3.2 69/13.5 81/51 0.87/0.6236 D160/23 8.95 730 1.11 16.6/4.5 108/18 87/62 0.89/0.58

80JM/25/6-12/9/... 935 12 F2265 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.5322 F2269 1.3 460 0.15 4/1.4 14/2.4 68/25 0.70/0.6336 D132/19 3 480 0.37 8.4/2.3 50/6.5 75/39 0.69/0.60

80JM/25/4-8/9/... 1440 12 F2269 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.6520 D132/19 4.1 725 0.51 9.5/2.2 55/9 79/54 0.79/0.6426 D132/26 5.6 730 0.7 11.5/3.2 69/13.5 81/51 0.87/0.6236 D160/23 8.95 730 1.11 16.6/4.5 108/18 87/62 0.89/0.58

80JM/31/2-4/9/... 2910 8 D160/32 14.9 1480 1.86 27.5/5.2 248/42 89/73 0.88/0.7010 D180/31 17.9 1480 2.24 33/6.6 249/53 89/77 0.87/0.63

90JM/25/6-12/3/... 935 20 F2265 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.5328 F2269 1.3 460 0.15 4/1.4 14/2.4 68/25 0.70/0.6332 D132/19 3 480 0.37 8.4/2.3 50/6.5 75/39 0.69/0.60

90JM/25/4-8/3/... 1440 12 F2265 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.6520 F2269 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.6526 D132/19 4.1 725 0.51 9.5/2.2 55/9 79/54 0.79/0.6432 D132/26 5.6 730 0.7 11.5/3.2 69/13.5 81/51 0.87/0.62

90JM/25/6-12/6/... 935 10 F2265 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.5318 F2269 1.3 460 0.15 4/1.4 14/2.4 68/25 0.70/0.6332 D132/19 3 480 0.37 8.4/2.3 50/6.5 75/39 0.69/0.60

90JM/25/4-8/6/... 1440 10 F2269 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.6516 D132/19 4.1 725 0.51 9.5/2.2 55/9 79/54 0.79/0.6422 D132/26 5.6 730 0.7 11.5/3.2 69/13.5 81/51 0.87/0.6230 D160/23 8.95 730 1.11 16.6/4.5 108/18 87/62 0.89/0.5832 D160/30 13.1 730 1.64 27/5.8 202/32 87/66 0.80/0.62

90JM/25/6-12/9/... 935 12 F2269 1.3 460 0.15 4/1.4 14/2.4 68/25 0.70/0.6326 D132/19 3 480 0.37 8.4/2.3 50/6.5 75/39 0.69/0.6036 D132/26 4.48 480 0.56 10.5/3.4 63/10 79/43 0.75/0.58

90JM/25/4-8/9/... 1440 10 D132/19 4.1 725 0.51 9.5/2.2 55/9 79/54 0.79/0.6414 D132/26 5.6 730 0.7 11.5/3.2 69/13.5 81/51 0.87/0.6222 D160/23 8.95 730 1.11 16.6/4.5 108/18 87/62 0.89/0.5832 D160/30 13.1 730 1.64 27/5.8 202/32 87/66 0.80/0.62

100JM/25/6-12/3/... 935 12 F2265 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.5320 F2269 1.3 460 0.15 4/1.4 14/2.4 68/25 0.70/0.6332 D132/19 3 480 0.37 8.4/2.3 50/6.5 75/39 0.69/0.60

Page 39: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules:Two Speed (Full and Half Dual Wound)

41

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

100JM/25/4-8/3/... 1440 12 F2269 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.6518 D132/19 4.1 725 0.51 9.5/2.2 55/9 79/54 0.79/0.6424 D132/26 5.6 730 0.7 11.5/3.2 69/13.5 81/51 0.87/0.6232 D160/23 8.95 730 1.11 16.6/4.5 108/18 87/62 0.89/0.58

100JM/25/6-12/6/... 950 10 F2269 1.3 460 0.15 4/1.4 14/2.4 68/25 0.70/0.6324 D132/19 3 480 0.37 8.4/2.3 50/6.5 75/39 0.69/0.6032 D132/26 4.48 480 0.56 10.5/3.4 63/10 79/43 0.75/0.58

100JM/25/4-8/6/... 1450 10 D132/19 4.1 725 0.51 9.5/2.2 55/9 79/54 0.79/0.6414 D132/26 5.6 730 0.7 11.5/3.2 69/13.5 81/51 0.87/0.6222 D160/23 8.95 730 1.11 16.6/4.5 108/18 87/62 0.89/0.5830 D160/30 13.1 730 1.64 27/5.8 202/32 87/66 0.80/0.62

100JM/25/6-12/9/... 960 18 D132/19 3 480 0.37 8.4/2.3 50/6.5 75/39 0.69/0.6024 D132/26 4.48 480 0.56 10.5/3.4 63/10 79/43 0.75/0.5834 D160/27 6.71 480 0.82 15.6/4.6 93/14 81/50 0.76/0.5236 D160/34 9.33 480 1.12 21/5.7 125/18 83/52 0.78/0.54

100JM/25/4-8/9/... 1470 8 D132/26 5.6 730 0.7 11.5/3.2 69/13.5 81/51 0.87/0.6214 D160/23 8.95 730 1.11 16.6/4.5 108/18 87/62 0.89/0.5822 D160/30 13.1 730 1.64 27/5.8 202/32 87/66 0.80/0.62

100JM/31/4-8/9/... 1470 8 D132/26 5.6 730 0.7 11.5/3.2 69/13.5 81/51 0.87/0.6214 D160/23 8.95 730 1.11 16.6/4.5 108/18 87/62 0.89/0.5822 D160/30 13.1 730 1.64 27/5.8 202/32 87/66 0.80/0.6222 D180/29 13.8 740 1.72 27/6.2 189/31 88/69 0.84/0.5928 D180/35 17.9 740 1.24 34.2/7.8 238/39 89/70 0.85/0.59

100JM/40/4-8/9/... 1470 12 D160/23 8.95 730 1.11 16.6/4.5 108/18 87/62 0.89/0.5820 D160/30 13.1 730 1.64 27/5.8 202/32 87/66 0.80/0.6220 D180/29 13.8 740 1.72 27/6.2 189/31 88/69 0.84/0.5924 D180/35 17.9 740 1.24 34.2/7.8 238/39 89/70 0.85/0.5928 D200/36 20.9 740 2.61 40/9.3 283/47 89/74 0.84/0.5436 D200/46 29.1 740 3.58 55/12.5 385/62 90/75 0.85/0.5540 W225/M 40 735 6 75/22 563/132 91.5/83.5 0.84/0.63

112JM/40/6-12/6/... 960 12 D132/19 3 480 0.37 8.4/2.3 50/6.5 75/39 0.69/0.6018 D132/26 4.48 480 0.56 10.5/3.4 63/10 79/43 0.75/0.5824 D160/27 6.71 480 0.82 15.6/4.6 93/14 81/50 0.76/0.5232 D160/34 9.33 480 1.12 21/5.7 125/18 83/52 0.78/0.54

112JM/40/4-8/6/... 1470 10 D160/23 8.95 730 1.11 16.6/4.5 108/18 87/62 0.89/0.5816 D160/30 13.1 730 1.64 27/5.8 202/32 87/66 0.80/0.6216 D180/29 13.8 740 1.72 27/6.2 189/31 88/69 0.84/0.5920 D180/35 17.9 740 1.24 34.2/7.8 238/39 89/70 0.85/0.5922 D200/36 20.9 740 2.61 40/9.3 283/47 89/74 0.84/0.5430 D200/46 29.1 740 3.58 55/12.5 385/62 90/75 0.85/0.5532 W225/M 40 735 6 75/22 563/132 91.5/83.5 0.84/0.63

112JM/40/6-12/9/... 960 12 D132/26 4.48 480 0.56 10.5/3.4 63/10 79/43 0.75/0.5820 D160/27 6.71 480 0.82 15.6/4.6 93/14 81/50 0.76/0.5226 D160/34 9.33 480 1.12 21/5.7 125/18 83/52 0.78/0.5432 D180/35 13.1 485 1.64 28/6.2 173/21 86/62 0.78/0.6236 D200/38 16.4 490 2.05 35/7.1 230/23 86/71 0.78/0.59

112JM/40/4-8/9/... 1470 10 D160/30 13.1 730 1.64 27/5.8 202/32 87/66 0.80/0.6210 D180/29 13.8 740 1.72 27/6.2 189/31 88/69 0.84/0.5916 D180/35 17.9 740 1.24 34.2/7.8 238/39 89/70 0.85/0.5918 D200/36 20.9 740 2.61 40/9.3 283/47 89/74 0.84/0.5424 D200/46 29.1 740 3.58 55/12.5 385/62 90/75 0.85/0.5530 W225/M 40 735 6 75/22 563/132 91.5/83.5 0.84/0.6334 W225/MF 48 735 9.5 91/26 683/156 92.0/84.5 0.83/0.63

Page 40: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules:Two Speed (Full and Half Dual Wound)

42

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

112JM/50/6-12/12/... 960 10 D132/26 4.48 480 0.56 10.5/3.4 63/10 79/43 0.75/0.5818 D160/27 6.71 480 0.82 15.6/4.6 93/14 81/50 0.76/0.5224 D160/34 9.33 480 1.12 21/5.7 125/18 83/52 0.78/0.5430 D180/35 13.1 485 1.64 28/6.2 173/21 86/62 0.78/0.6236 D200/38 16.4 490 2.05 35/7.1 230/23 86/71 0.78/0.59

112JM/50/4-8/12/... 1470 8 D160/30 13.1 730 1.64 27/5.8 202/32 87/66 0.80/0.628 D180/29 13.8 740 1.72 27/6.2 189/31 88/69 0.84/0.59

14 D180/35 17.9 740 1.24 34.2/7.8 238/39 89/70 0.85/0.5916 D200/36 20.9 740 2.61 40/9.3 283/47 89/74 0.84/0.5422 D200/46 29.1 740 3.58 55/12.5 385/62 90/75 0.85/0.5528 W225/M 40 735 6 75/22 563/132 91.5/83.5 0.84/0.6332 W225/MF 48 735 9.5 91/26 683/156 92.0/84.5 0.83/0.6336 W250/M 67 735 13 123/37 861/204 92.5/85.0 0.85/0.60

125JM/40/6-12/6/... 960 10 D132/26 4.48 480 0.56 10.5/3.4 63/10 79/43 0.75/0.5816 D160/27 6.71 480 0.82 15.6/4.6 93/14 81/50 0.76/0.5222 D160/34 9.33 480 1.12 21/5.7 125/18 83/52 0.78/0.5428 D180/35 13.1 485 1.64 28/6.2 173/21 86/62 0.78/0.6232 D200/38 16.4 490 2.05 35/7.1 230/23 86/71 0.78/0.59

125JM/40/4-8/6/... 1470 10 D160/30 13.1 730 1.64 27/5.8 202/32 87/66 0.80/0.6210 D180/29 13.8 740 1.72 27/6.2 189/31 88/69 0.84/0.5914 D180/35 17.9 740 1.24 34.2/7.8 238/39 89/70 0.85/0.5916 D200/36 20.9 740 2.61 40/9.3 283/47 89/74 0.84/0.5420 D200/46 29.1 740 3.58 55/12.5 385/62 90/75 0.85/0.5526 W225/M 40 735 6 75/22 563/132 91.5/83.5 0.84/0.6330 W225/MF 48 735 9.5 91/26 683/156 92.0/84.5 0.83/0.6332 W250/M 67 735 13 123/37 861/204 92.5/85.0 0.85/0.6

125JM/40/6-12/9/... 960 12 D160/27 6.71 480 0.82 15.6/4.6 93/14 81/50 0.76/0.5218 D160/34 9.33 480 1.12 21/5.7 125/18 83/52 0.78/0.5422 D180/35 13.1 485 1.64 28/6.2 173/21 86/62 0.78/0.6226 D200/38 16.4 490 2.05 35/7.1 230/23 86/71 0.78/0.5932 D200/46 20.9 485 2.61 46/10.7 300/37 87/65 0.75/0.5434 W225/M 22.5 485 4.5 44/17 286/85 89/72 0.83/0.5436 W225/MF 28 485 5.6 54/21 351/105 89.5/72.5 0.83/0.54

125JM/40/4-8/9/... 1470 8 D180/35 17.9 740 1.24 34.2/7.8 238/39 89/70 0.85/0.5910 D200/36 20.9 740 2.61 40/9.3 283/47 89/74 0.84/0.5416 D200/46 29.1 740 3.58 55/12.5 385/62 90/75 0.85/0.5520 W225/M 40 735 6 75/22 563/132 91.5/83.5 0.84/0.6324 W225/MF 48 735 9.5 91/26 683/156 92.0/84.5 0.83/0.6330 W250/M 67 735 13 123/37 861/204 92.5/85.0 0.85/0.6034 W250/MF 81 735 18 146/45 1022/248 93.0/88.0 0.86/0.60

125JM/50/4-8/6/... 1470 10 D160/30 13.1 730 1.64 27/5.8 202/32 87/66 0.80/0.6210 D180/29 13.8 740 1.72 27/6.2 189/31 88/69 0.84/0.5912 D180/35 17.9 740 1.24 34.2/7.8 238/39 89/70 0.85/0.5916 D200/36 20.9 740 2.61 40/9.3 283/47 89/74 0.84/0.5420 D200/46 29.1 740 3.58 55/12.5 385/62 90/75 0.85/0.5526 W225/M 40 735 6 75/22 563/132 91.5/83.5 0.84/0.6330 W225/MF 48 735 9.5 91/26 683/156 92.0/84.5 0.83/0.6332 W250/M 67 735 13 123/37 861/204 92.5/85.0 0.85/0.60

125JM/50/4-8/9/... 1470 8 D180/35 17.9 740 1.24 34.2/7.8 238/39 89/70 0.85/0.5910 D200/36 20.9 740 2.61 40/9.3 283/47 89/74 0.84/0.5416 D200/46 29.1 740 3.58 55/12.5 385/62 90/75 0.85/0.5522 W225/M 40 735 6 75/22 563/132 91.5/83.5 0.84/0.6324 W225/MF 48 735 9.5 91/26 683/156 92.0/84.5 0.83/0.6332 W250/M 67 735 13 123/37 861/204 92.5/85.0 0.85/0.6036 W250/MF 81 735 18 146/45 1022/248 93.0/88.0 0.86/0.60

Page 41: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules:Two Speed (Full and Half Dual Wound)

43

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

125JM/50/6-12/12/... 960 8 D160/27 6.71 480 0.82 15.6/4.6 93/14 81/50 0.76/0.5214 D160/34 9.33 480 1.12 21/5.7 125/18 83/52 0.78/0.5420 D180/35 13.1 485 1.64 28/6.2 173/21 86/62 0.78/0.6224 D200/38 16.4 490 2.05 35/7.1 230/23 86/71 0.78/0.5928 D200/46 20.9 485 2.61 46/10.7 300/37 87/65 0.75/0.5430 W225/M 22.5 485 4.5 44/17 286/85 89/72 0.83/0.5436 W225/MF 28 485 5.6 54/21 351/105 89.5/72.5 0.83/0.54

125JM/50/4-8/12/... 1470 8 D200/36 20.9 740 2.61 40/9.3 283/47 89/74 0.84/0.5412 D200/46 29.1 740 3.58 55/12.5 385/62 90/75 0.85/0.5518 W225/M 40 735 6 75/22 563/132 91.5/83.5 0.84/0.6320 W225/MF 48 735 9.5 91/26 683/156 92.0/84.5 0.83/0.6328 W250/M 67 735 13 123/37 861/204 92.5/85.0 0.85/0.6032 W250/MF 81 735 18 146/45 1022/248 93.0/88.0 0.86/0.60

140JM/40/6-12/6/... 960 10 D160/27 6.71 480 0.82 15.6/4.6 93/14 81/50 0.76/0.5214 D160/34 9.33 480 1.12 21/5.7 125/18 83/52 0.78/0.5420 D180/35 13.1 485 1.64 28/6.2 173/21 86/62 0.78/0.6224 D200/38 16.4 490 2.05 35/7.1 230/23 86/71 0.78/0.5930 D200/46 20.9 485 2.61 46/10.7 300/37 87/65 0.75/0.5430 W225/M 22.5 485 4.5 44/17 286/85 89/72 0.83/0.5436 W225/MF 28 485 5.6 54/21 351/105 89.5/72.5 0.83/0.54

140JM/50/6-12/9/... 960 10 D160/34 9.33 480 1.12 21/5.7 125/18 83/52 0.78/0.5416 D180/35 13.1 485 1.64 28/6.2 173/21 86/62 0.78/0.6220 D200/38 16.4 490 2.05 35/7.1 230/23 86/71 0.78/0.5924 D200/46 20.9 485 2.61 46/10.7 300/37 87/65 0.75/0.5424 W225/M 22.5 485 4.5 44/17 286/85 89/72 0.83/0.5430 W225/MF 28 485 5.6 54/21 351/105 89.5/72.5 0.83/0.5436 W250/M 36 485 7.2 69/26 483/143 90.3/74 0.84/0.55

140JM/50/4-8/9/... 1470 10 D200/46 29.1 740 3.58 55/12.5 385/62 90/75 0.85/0.5514 W225/M 40 735 6 75/22 563/132 91.5/83.5 0.84/0.6316 W225/MF 48 735 9.5 91/26 683/156 92.0/84.5 0.83/0.6322 W250/M 67 735 13 123/37 861/204 92.5/85.0 0.85/0.6026 W250/MF 81 735 18 146/45 1022/248 93.0/88.0 0.86/0.60

140JM/50/6-12/12/... 960 8 D160/34 9.33 480 1.12 21/5.7 125/18 83/52 0.78/0.5412 D180/35 13.1 485 1.64 28/6.2 173/21 86/62 0.78/0.6216 D200/38 16.4 490 2.05 35/7.1 230/23 86/71 0.78/0.5920 D200/46 20.9 485 2.61 46/10.7 300/37 87/65 0.75/0.5422 W225/M 22.5 485 4.5 44/17 286/85 89/72 0.83/0.5426 W225/MF 28 485 5.6 54/21 351/105 89.5/72.5 0.83/0.5432 W250/M 36 485 7.2 69/26 483/143 90.3/74 0.84/0.5534 W250/MF 42 490 8.4 79/28 553/154 90.9/75 0.84/0.55

140JM/50/4-8/12/... 1470 10 W225/M 40 735 6 75/22 563/132 91.5/83.5 0.84/0.6312 W225/MF 48 735 9.5 91/26 683/156 92.0/84.5 0.83/0.6320 W250/M 67 735 13 123/37 861/204 92.5/85.0 0.85/0.6022 W250/MF 81 735 18 146/45 1022/248 93.0/88.0 0.86/0.60

160JM/40/6-12/6/... 960 10 D180/35 13.1 485 1.64 28/6.2 173/21 86/62 0.78/0.6214 D200/38 16.4 490 2.05 35/7.1 230/23 86/71 0.78/0.5918 D200/46 20.9 485 2.61 46/10.7 300/37 87/65 0.75/0.5420 W225/M 22.5 485 4.5 44/17 286/85 89/72 0.83/0.5422 W225/MF 28 485 5.6 54/21 351/105 89.5/72.5 0.83/0.5428 W250/M 36 485 7.2 69/26 483/143 90.3/74 0.84/0.5530 W250/MF 42 490 8.4 79/28 553/154 90.9/75 0.84/0.55

Page 42: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules:Two Speed (Full and Half Dual Wound)

44

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

160JM/40/6-12/9/... 960 8 D200/38 16.4 490 2.05 35/7.1 230/23 86/71 0.78/0.5912 D200/46 20.9 485 2.61 46/10.7 300/37 87/65 0.75/0.5414 W225/M 22.5 485 4.5 44/17 286/85 89/72 0.83/0.5418 W225/MF 28 485 5.6 54/21 351/105 89.5/72.5 0.83/0.5422 W250/M 36 485 7.2 69/26 483/143 90.3/74 0.84/0.5524 W250/MF 42 490 8.4 79/28 553/154 90.9/75 0.84/0.55

160JM/50/6-12/9/... 960 10 D200/38 16.4 490 2.05 35/7.1 230/23 86/71 0.78/0.5914 D200/46 20.9 485 2.61 46/10.7 300/37 87/65 0.75/0.5414 W225/M 22.5 485 4.5 44/17 286/85 89/72 0.83/0.5418 W225/MF 28 485 5.6 54/21 351/105 89.5/72.5 0.83/0.5422 W250/M 36 485 7.2 69/26 483/143 90.3/74 0.84/0.5524 W250/MF 42 490 8.4 79/28 553/154 90.9/75 0.84/0.55

160JM/50/6-12/12/... 960 10 D200/46 20.9 485 2.61 46/10.7 300/37 87/65 0.75/0.5410 W225/M 22.5 485 4.5 44/17 286/85 89/72 0.83/0.5414 W225/MF 28 485 5.6 54/21 351/105 89.5/72.5 0.83/0.5418 W250/M 36 485 7.2 69/26 483/143 90.3/74 0.84/0.5522 W250/MF 42 490 8.4 79/28 553/154 90.9/75 0.84/0.55

Page 43: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules:Two Speed (Full and Other Pole Change)

45

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

31JM/16/6-8/5/... 900 40 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.76

31JM/16/4-6/5/... 1420 40 BT5 0.15 900 0.04 0.6/0.3 2.3/0.7 58/30 0.63/0.65

35JM/16/6-8/5/... 900 40 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.76

35JM/16/4-6/5/... 1420 38 BT5 0.15 900 0.04 0.6/0.3 2.3/0.7 58/30 0.63/0.6540 BT9 0.26 900 0.065 0.95/0.45 3.3/1 58/30 0.65/0.7

40JM/16/6-8/5/... 900 40 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.76

40JM/16/4-6/5/... 1420 24 BT5 0.15 900 0.04 0.6/0.3 2.3/0.7 58/30 0.63/0.6536 BT9 0.26 900 0.065 0.95/0.45 3.3/1 58/30 0.65/0.740 CT5 0.5 900 0.14 1.3/0.65 4.8/1.4 78/48 0.71/0.65

45JM/16/6-8/5/... 900 40 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.76

45JM/16/4-6/5/... 1420 14 BT5 0.15 900 0.04 0.6/0.3 2.3/0.7 58/30 0.63/0.6524 BT9 0.26 900 0.065 0.95/0.45 3.3/1 58/30 0.65/0.738 CT5 0.5 900 0.14 1.3/0.65 4.8/1.4 78/48 0.71/0.6540 CT9 0.9 940 0.27 2.4/1.5 10.8/3.2 75/45 0.72/0.58

45JM/20/6-8/3/... 900 36 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.76

45JM/20/4-6/3/... 1420 20 BT5 0.15 900 0.04 0.6/0.3 2.3/0.7 58/30 0.63/0.6532 BT9 0.26 900 0.065 0.95/0.45 3.3/1 58/30 0.65/0.736 CT5 0.5 900 0.14 1.3/0.65 4.8/1.4 78/48 0.71/0.65

45JM/20/6-8/6/... 900 40 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.76

45JM/20/4-6/6/... 1420 12 BT5 0.15 900 0.04 0.6/0.3 2.3/0.7 58/30 0.63/0.6522 BT9 0.26 900 0.065 0.95/0.45 3.3/1 58/30 0.65/0.738 CT5 0.5 900 0.14 1.3/0.65 4.8/1.4 78/48 0.71/0.6540 CT9 0.9 940 0.27 2.4/1.5 10.8/3.2 75/45 0.72/0.58

50JM/16/6-8/5/... 915 40 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.76

50JM/16/4-6/5/... 1420 14 BT9 0.26 900 0.065 0.95/0.45 3.3/1 58/30 0.65/0.726 CT5 0.5 900 0.14 1.3/0.65 4.8/1.4 78/48 0.71/0.6540 CT9 0.9 940 0.27 2.4/1.5 10.8/3.2 75/45 0.72/0.58

50JM/20/6-8/3/... 915 36 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.76

50JM/20/4-6/3/... 1420 14 BT5 0.15 900 0.04 0.6/0.3 2.3/0.7 58/30 0.63/0.6522 BT9 0.26 900 0.065 0.95/0.45 3.3/1 58/30 0.65/0.736 CT5 0.5 900 0.14 1.3/0.65 4.8/1.4 78/48 0.71/0.65

50JM/20/6-8/6/... 915 40 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.76

50JM/20/4-6/6/... 1420 14 BT9 0.26 900 0.065 0.95/0.45 3.3/1 58/30 0.65/0.726 CT5 0.5 900 0.14 1.3/0.65 4.8/1.4 78/48 0.71/0.6540 CT9 0.9 940 0.27 2.4/1.5 10.8/3.2 75/45 0.72/0.58

56JM/16/6-8/5/... 900 30 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.7640 CT9 0.48 700 0.2 2.4/1.2 4.9/1.4 58/39 0.50/0.61

56JM/16/4-6/5/... 1420 18 CT5 0.5 900 0.14 1.3/0.65 4.8/1.4 78/48 0.71/0.6528 CT9 0.9 940 0.27 2.4/1.5 10.8/3.2 75/45 0.72/0.58

Page 44: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules:Two Speed (Full and Other Pole Change)

46

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

56JM/20/6-8/3/... 900 36 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.76

56JM/20/4-6/3/... 1420 14 BT9 0.26 900 0.065 0.95/0.45 3.3/1 58/30 0.65/0.726 CT5 0.5 900 0.14 1.3/0.65 4.8/1.4 78/48 0.71/0.6536 CT9 0.9 940 0.27 2.4/1.5 10.8/3.2 75/45 0.72/0.58

56JM/20/6-8/6/... 900 28 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.7640 CT9 0.48 700 0.2 2.4/1.2 4.9/1.4 58/39 0.50/0.61

56JM/20/4-6/6/... 1420 16 CT5 0.5 900 0.14 1.3/0.65 4.8/1.4 78/48 0.71/0.6526 CT9 0.9 940 0.27 2.4/1.5 10.8/3.2 75/45 0.72/0.5840 F2225 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.66

63JM/20/6-8/3/... 900 24 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.7636 CT9 0.48 700 0.2 2.4/1.2 4.9/1.4 58/39 0.50/0.61

63JM/20/4-6/3/... 1420 12 CT5 0.5 900 0.14 1.3/0.65 4.8/1.4 78/48 0.71/0.6522 CT9 0.9 940 0.27 2.4/1.5 10.8/3.2 75/45 0.72/0.5836 F2225 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.66

63JM/20/6-8/6/... 900 16 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.7626 CT9 0.48 700 0.2 2.4/1.2 4.9/1.4 58/39 0.50/0.6136 F2265 1 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.66

63JM/20/4-6/6/... 1420 14 CT9 0.9 940 0.27 2.4/1.5 10.8/3.2 75/45 0.72/0.5828 F2225 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.6636 PM112 3.5 940 1.04 8/7 46/14 81/80 0.78/0.47

63JM/25/4-6/6/... 1440 34 F2225 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.6636 PM112 3.5 940 1.04 8/4 46/14 81/80 0.78/0.47

63JM/25/6-8/9/... 935 40 F2265 1 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.66

63JM/25/4-6/9/... 1440 28 F2225 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.6640 PM112 3.5 940 1.04 8/4 46/14 81/80 0.78/0.47

71JM/20/6-8/3/... 900 14 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.7624 CT9 0.48 700 0.2 2.4/1.2 4.9/1.4 58/39 0.50/0.6136 F2265 1 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.66

71JM/20/4-6/3/... 1440 12 CT9 0.9 940 0.27 2.4/1.5 10.8/3.2 75/45 0.72/0.5828 F2225 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.6636 PM112 3.5 940 1.04 8/4 46/14 81/80 0.78/0.47

71JM/20/6-8/6/... 900 16 CT9 0.48 700 0.2 2.4/1.2 4.9/1.4 58/39 0.50/0.6130 F2265 1 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.6636 F2269 1.8 690 0.76 5.8/3 25/7 73/54 0.61/0.65

71JM/20/4-6/6/... 1440 18 F2225 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.6630 PM112 3.5 940 1.04 8/4 46/14 81/80 0.78/0.47

71JM/25/4-6/3/... 1440 32 F2225 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.66

71JM/25/6-8/6/... 935 34 F2265 1 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.6636 F2269 1.8 690 0.76 5.8/3 25/7 73/54 0.61/0.65

71JM/25/4-6/6/... 1440 22 F2225 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.6634 PM112 3.5 940 1.04 8/4 46/14 81/80 0.78/0.4736 D132/21 5.6 970 1.64 11/4.5 66/19 84/74 0.88/0.71

Page 45: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules:Two Speed (Full and Other Pole Change)

47

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

71JM/25/6-8/9/... 935 28 F2265 1 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.6636 F2269 1.8 690 0.76 5.8/3 25/7 73/54 0.61/0.65

71JM/25/4-6/9/... 1440 16 F2225 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.6626 PM112 3.5 940 1.04 8/7 46/14 81/80 0.78/0.4736 D132/21 5.6 970 1.64 11/4.5 66/19 84/74 0.88/0.71

80JM/20/6-8/3/... 935 8 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.7616 CT9 0.48 700 0.2 2.4/1.2 4.9/1.4 58/39 0.50/0.6130 F2265 1 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.6636 F2269 1.8 690 0.76 5.8/3 25/7 73/54 0.61/0.65

80JM/20/4-6/3/... 1440 18 F2225 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.6628 PM112 3.5 940 1.04 8/4 46/14 81/80 0.78/0.47

80JM/20/6-8/6/... 935 8 CT9 0.48 700 0.2 2.4/1.2 4.9/1.4 58/39 0.50/0.6118 F2265 1 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.6632 F2269 1.8 690 0.76 5.8/3 25/7 73/54 0.61/0.65

80JM/20/4-6/6/... 1440 10 F2225 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.6618 PM112 3.5 940 1.04 8/4 46/14 81/80 0.78/0.47

80JM/25/6-8/3/... 935 32 F2265 1 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.66

80JM/25/4-6/3/... 1440 22 F2225 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.6632 PM112 3.5 940 1.04 8/4 46/14 81/80 0.78/0.47

80JM/25/6-8/6/... 935 24 F2265 1 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.6636 F2269 1.8 690 0.76 5.8/3 25/7 73/54 0.61/0.65

80JM/25/4-6/6/... 1440 12 F2225 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.6624 PM112 3.5 940 1.04 8/4 46/14 81/80 0.78/0.4732 D132/21 5.6 970 1.64 11/4.5 66/19 84/74 0.88/0.7136 D132/24 7 970 2.09 13.8/5.6 81/23.8 82/75 0.87/0.72

80JM/25/6-8/9/... 935 18 F2265 1 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.6630 F2269 1.8 690 0.76 5.8/3 25/7 73/54 0.61/0.6536 D132/19 3 725 1.27 11/3.9 70/17.5 73/70 0.54/0.67

80JM/25/4-6/9/... 1440 8 F2225 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.6616 PM112 3.5 940 1.04 8/4 46/14 81/80 0.78/0.4726 D132/21 5.6 970 1.64 11/4.5 66/19 84/74 0.88/0.7130 D132/24 7 970 2.09 13.8/5.6 81/23.8 82/75 0.87/0.7232 D160/27 8.21 960 2.42 15.6/5 97.5/20 86/83 0.90/0.8636 D160/34 11.2 950 3.36 21.8/7.1 142/28 86/83 0.90/0.86

90JM/25/6-8/3/... 935 24 F2265 1 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.6632 F2269 1.8 690 0.76 5.8/3 25/7 73/54 0.61/0.65

90JM/25/4-6/3/... 1440 14 F2225 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.6624 PM112 3.5 940 1.04 8/4 46/14 81/80 0.78/0.4732 D132/21 5.6 970 1.64 11/4.5 66/19 84/74 0.88/0.71

90JM/25/6-8/6/... 935 14 F2265 1 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.6626 F2269 1.8 690 0.76 5.8/3 25/7 73/54 0.61/0.6532 D132/19 3 725 1.27 11/3.9 70/17.5 73/70 0.54/0.67

Page 46: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules:Two Speed (Full and Other Pole Change)

48

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

90JM/25/4-6/6/... 1440 14 PM112 3.5 940 1.04 8/4 46/14 81/80 0.78/0.4722 D132/21 5.6 970 1.64 11/4.5 66/19 84/74 0.88/0.7126 D132/24 7 970 2.09 13.8/5.6 81/23.8 82/75 0.87/0.7228 D160/27 8.21 960 2.42 15.6/5 97.5/20 86/83 0.90/0.8632 D160/34 11.2 950 3.36 21.8/7.1 142/28 86/83 0.90/0.86

90JM/25/6-8/9/... 935 8 F2265 1 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.6618 F2269 1.8 690 0.76 5.8/3 25/7 73/54 0.61/0.6524 D132/19 3 725 1.27 11/3.9 70/17.5 73/70 0.54/0.6736 D132/26 4.55 720 1.9 11.9/5.2 77.8/20.8 79/73 0.69/0.72

90JM/25/4-6/9/... 1440 8 PM112 3.5 940 1.04 8/4 46/14 81/80 0.78/0.4714 D132/21 5.6 970 1.64 11/4.5 66/19 84/74 0.88/0.7118 D132/24 7 970 2.09 13.8/5.6 81/23.8 82/75 0.87/0.7220 D160/27 8.21 960 2.42 15.6/5 97.5/20 86/83 0.90/0.8628 D160/34 11.2 950 3.36 21.8/7.1 142/28 86/83 0.90/0.86

100JM/25/6-8/3/... 935 16 F2265 1 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.6628 F2269 1.8 690 0.76 5.8/3 25/7 73/54 0.61/0.6532 D132/19 3 725 1.27 11/3.9 70/17.5 73/70 0.54/0.67

100JM/25/4-6/3/... 1440 8 F2225 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.6616 PM112 3.5 940 1.04 8/4 46/14 81/80 0.78/0.4724 D132/21 5.6 970 1.64 11/4.5 66/19 84/74 0.88/0.7128 D132/24 7 970 2.09 13.8/5.6 81/23.8 82/75 0.87/0.7230 D160/27 8.21 960 2.42 15.6/5 97.5/20 86/83 0.90/0.8632 D160/34 11.2 950 3.36 21.8/7.1 142/28 86/83 0.90/0.86

100JM/25/6-8/6/... 950 8 F2265 1 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.6618 F2269 1.8 690 0.76 5.8/3 25/7 73/54 0.61/0.6524 D132/19 3 725 1.27 11/3.9 70/17.5 73/70 0.54/0.6732 D132/26 4.55 720 1.9 11.9/5.2 77.8/20.8 79/73 0.69/0.72

100JM/25/4-6/6/... 1450 8 PM112 3.5 940 1.04 8/4 46/14 81/80 0.78/0.4714 D132/21 5.6 970 1.64 11/4.5 66/19 84/74 0.88/0.7118 D132/24 7 970 2.09 13.8/5.6 81/23.8 82/75 0.87/0.7220 D160/27 8.21 960 2.42 15.6/5 97.5/20 86/83 0.90/0.8626 D160/34 11.2 950 3.36 21.8/7.1 142/28 86/83 0.90/0.86

100JM/25/6-8/9/... 960 12 F2269 1.8 690 0.76 5.8/3 25/7 73/54 0.61/0.6518 D132/19 3 725 1.27 11/3.9 70/17.5 73/70 0.54/0.6726 D132/26 4.55 720 1.9 11.9/5.2 77.8/20.8 79/73 0.69/0.7228 DF132/MK 5.1 710 2.2 12.3/6.5 74/19.8 82/71 0.73/0.6836 DF160/LM 7.5 710 3.2 16.2/8.2 105/32.8 85/78 0.78/0.72

100JM/25/4-6/9/... 1470 8 D132/21 5.6 970 1.64 11/4.5 66/19 84/74 0.88/0.7112 D132/24 7 970 2.09 13.8/5.6 81/23.8 82/75 0.87/0.7214 D160/27 8.21 960 2.42 15.6/5 97.5/20 86/83 0.90/0.8620 D160/34 11.2 950 3.36 21.8/7.1 142/28 86/83 0.90/0.86

100JM/31/4-6/9/... 1470 8 D132/21 5.6 970 1.64 11/4.5 66/19 84/74 0.88/0.7112 D132/24 7 970 2.09 13.8/5.6 81/23.8 82/75 0.87/0.7214 D160/27 8.21 960 2.42 15.6/5 97.5/20 86/83 0.90/0.8618 D160/34 11.2 950 3.36 21.8/7.1 142/28 86/83 0.90/0.8622 D180/29 12.7 960 3.73 23.8/7.5 156/30 87/85 0.89/0.8526 D180/35 16.4 960 4.85 30/9.8 195/39 88/86 0.90/0.86

Page 47: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules:Two Speed (Full and Other Pole Change)

49

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

100JM/40/4-6/9/... 1470 8 D132/24 7 970 2.09 13.8/5.6 81/23.8 82/75 0.87/0.7210 D160/27 8.21 960 2.42 15.6/5 97.5/20 86/83 0.90/0.8616 D160/34 11.2 950 3.36 21.8/7.1 142/28 86/83 0.90/0.8618 D180/29 12.7 960 3.73 23.8/7.5 156/30 87/85 0.89/0.8522 D180/35 16.4 960 4.85 30/9.8 195/39 88/86 0.90/0.8628 D200/38 22.4 970 6.64 41.5/13.3 270/53 89/87 0.88/0.8334 D200/46 28.3 970 8.39 51.9/17.1 337/68 90/88 0.89/0.8438 W200/LF 31 960 10 57/24 370/132 90.8/85.3 0.86/0.7040 W200/LFR 38 960 12 70/29 455/160 91/85.5 0.86/0.70

112JM/40/6-8/6/... 960 12 D132/19 3 725 1.27 11/3.9 70/17.5 73/70 0.54/0.6718 D132/26 4.55 720 1.9 11.9/5.2 77.8/20.8 79/73 0.69/0.7220 DF132/MK 5.1 710 2.2 12.3/6.5 74/19.8 82/71 0.73/0.6826 DF160/LM 7.5 710 3.2 16.2/8.2 105/32.8 85/78 0.78/0.7232 DF160/L 10 710 4.3 21/10.5 137/42 87/79 0.80/0.75

112JM/40/4-6/6/... 1470 8 D160/27 8.21 960 2.42 15.6/5 97.5/20 86/83 0.90/0.8612 D160/34 11.2 950 3.36 21.8/7.1 142/28 86/83 0.90/0.8614 D180/29 12.7 960 3.73 23.8/7.5 156/30 87/85 0.89/0.8518 D180/35 16.4 960 4.85 30/9.8 195/39 88/86 0.90/0.8624 D200/38 22.4 970 6.64 41.5/13.3 270/53 89/87 0.88/0.8328 D200/46 28.3 970 8.39 51.9/17.1 337/68 90/88 0.89/0.8430 W200/LF 31 960 10 57/24 370/132 90.8/85.3 0.86/0.7032 W200/LFR 38 960 12 70/29 455/160 91/85.5 0.86/0.70

112JM/40/6-8/9/... 960 14 D132/26 4.55 720 1.9 11.9/5.2 77.8/20.8 79/73 0.69/0.7216 DF132/MK 5.1 710 2.2 12.3/6.5 74/19.8 82/71 0.73/0.6822 DF160/LM 7.5 710 3.2 16.2/8.2 105/32.8 85/78 0.78/0.7226 DF160/L 10 710 4.3 21/10.5 137/42 87/79 0.80/0.7534 DF180/LM 14 720 6 28/14.6 182/59 87/78 0.81/0.7736 DF180/L 17 720 7.3 34/17.8 221/71 87/78 0.84/0.76

112JM/40/4-6/9/... 1470 8 D160/34 11.2 950 3.36 21.8/7.1 142/28 86/83 0.90/0.8610 D180/29 12.7 960 3.73 23.8/7.5 156/30 87/85 0.89/0.8514 D180/35 16.4 960 4.85 30/9.8 195/39 88/86 0.90/0.8620 D200/38 22.4 970 6.64 41.5/13.3 270/53 89/87 0.88/0.8324 D200/46 28.3 970 8.39 51.9/17.1 337/68 90/88 0.89/0.8426 W200/LF 31 960 10 57/24 370/132 90.8/85.3 0.86/0.7030 W200/LFR 38 960 12 70/29 455/160 91/85.5 0.86/0.7034 W225/M 47 970 15 86/35 602/210 92/87.5 0.86/0.7036 W225/MF 58 980 19 104/44 728/264 92.5/89 0.86/0.70

112JM/50/6-8/12/... 960 10 D132/26 4.55 720 1.9 11.9/5.2 77.8/20.8 79/73 0.69/0.7214 DF132/MK 5.1 710 2.2 12.3/6.5 74/19.8 82/71 0.73/0.6820 DF160/LM 7.5 710 3.2 16.2/8.2 105/32.8 85/78 0.78/0.7226 DF160/L 10 710 4.3 21/10.5 137/42 87/79 0.80/0.7532 DF180/LM 14 720 6 28/14.6 182/59 87/78 0.81/0.7736 DF180/L 17 720 7.3 34/17.8 221/71 87/78 0.84/0.76

112JM/50/4-6/12/... 1470 8 D180/29 12.7 960 3.73 23.8/7.5 156/30 87/85 0.89/0.8512 D180/35 16.4 960 4.85 30/9.8 195/39 88/86 0.90/0.8618 D200/38 22.4 970 6.64 41.5/13.3 270/53 89/87 0.88/0.8322 D200/46 28.3 970 8.39 51.9/17.1 337/68 90/88 0.89/0.8424 W200/LF 31 960 10 57/24 370/132 90.8/85.3 0.86/0.7028 W200/LFR 38 960 12 70/29 455/160 91/85.5 0.86/0.7032 W225/M 47 970 15 86/35 602/210 92/87.5 0.86/0.7036 W225/MF 58 980 19 104/44 728/264 92.5/89 0.86/0.70

Page 48: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules:Two Speed (Full and Other Pole Change)

50

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

125JM/40/6-8/6/... 960 12 D132/26 4.55 720 1.9 11.9/5.2 77.8/20.8 79/73 0.69/0.7212 DF132/MK 5.1 710 2.2 12.3/6.5 74/19.8 82/71 0.73/0.6818 DF160/LM 7.5 710 3.2 16.2/8.2 105/32.8 85/78 0.78/0.7224 DF160/L 10 710 4.3 21/10.5 137/42 87/79 0.80/0.7530 DF180/LM 14 720 6 28/14.6 182/59 87/78 0.81/0.7732 DF180/L 17 720 7.3 34/17.8 221/71 87/78 0.84/0.76

125JM/40/4-6/6/... 1470 8 D160/34 11.2 950 3.36 21.8/7.1 142/28 86/83 0.90/0.868 D180/29 12.7 960 3.73 23.8/7.5 156/30 87/85 0.89/0.85

12 D180/35 16.4 960 4.85 30/9.8 195/39 88/86 0.90/0.8616 D200/38 22.4 970 6.64 41.5/13.3 270/53 89/87 0.88/0.8320 D200/46 28.3 970 8.39 51.9/17.1 337/68 90/88 0.89/0.8422 W200/LF 31 960 10 57/24 370/132 90.8/85.3 0.86/0.7026 W200/LFR 38 960 12 70/29 455/160 91/85.5 0.86/0.7030 W225/M 47 970 15 86/35 602/210 92/87.5 0.86/0.7032 W225/MF 58 980 19 104/44 728/264 92.5/89 0.86/0.70

125JM/40/6-8/9/... 960 8 DF132/MK 5.1 710 2.2 12.3/6.5 74/19.8 82/71 0.73/0.6814 DF160/LM 7.5 710 3.2 16.2/8.2 105/32.8 85/78 0.78/0.7218 DF160/L 10 710 4.3 21/10.5 137/42 87/79 0.80/0.7524 DF180/LM 14 720 6 28/14.6 182/59 87/78 0.81/0.7728 DF180/L 17 720 7.3 34/17.8 221/71 87/78 0.84/0.7630 W200/LFG 18.6 720 8 38/22 266/99 89/82 0.78/0.6534 W200/LF 22 730 9.5 45/25 315/113 90/83 0.78/0.6536 W200/LFR 27 730 12 55/31 385/140 90/84 0.79/0.65

125JM/40/4-6/9/... 1470 12 D200/38 22.4 970 6.64 41.5/13.3 270/53 89/87 0.88/0.8316 D200/46 28.3 970 8.39 51.9/17.1 337/68 90/88 0.89/0.8416 W200/LF 31 960 10 57/24 370/132 90.8/85.3 0.86/0.7020 W200/LFR 38 960 12 70/29 455/160 91/85.5 0.86/0.7024 W225/M 47 970 15 86/35 602/210 92/87.5 0.86/0.7028 W225/MF 58 980 19 104/44 728/264 92.5/89 0.86/0.7034 W250/M 79 980 26 142/62 994/372 93.2/89.2 0.86/0.6836 W250/MF 95 985 31 171/74 1197/444 93.5/89.4 0.86/0.68

125JM/50/4-6/6/... 1470 8 D180/29 12.7 960 3.73 23.8/7.5 156/30 87/85 0.89/0.8512 D180/35 16.4 960 4.85 30/9.8 195/39 88/86 0.90/0.8616 D200/38 22.4 970 6.64 41.5/13.3 270/53 89/87 0.88/0.8320 D200/46 28.3 970 8.39 51.9/17.1 337/68 90/88 0.89/0.8422 W200/LF 31 960 10 57/24 370/132 90.8/85.3 0.86/0.7026 W200/LFR 38 960 12 70/29 455/160 91/85.5 0.86/0.7030 W225/M 47 970 15 86/35 602/210 92/87.5 0.86/0.7032 W225/MF 58 980 19 104/44 728/264 92.5/89 0.86/0.70

125JM/50/6-8/9/... 960 8 DF132/MK 5.1 710 2.2 12.3/6.5 74/19.8 82/71 0.73/0.6814 DF160/LM 7.5 710 3.2 16.2/8.2 105/32.8 85/78 0.78/0.7220 DF160/L 10 710 4.3 21/10.5 137/42 87/79 0.80/0.7524 DF180/LM 14 720 6 28/14.6 182/59 87/78 0.81/0.7728 DF180/L 17 720 7.3 34/17.8 221/71 87/78 0.84/0.7630 W200/LFG 18.6 720 8 38/22 266/99 89/82 0.78/0.6534 W200/LF 22 730 9.5 45/25 315/113 90/83 0.78/0.6536 W200/LFR 27 730 12 55/31 385/140 90/84 0.79/0.65

125JM/50/6-8/12/... 960 10 DF160/LM 7.5 710 3.2 16.2/8.2 105/32.8 85/78 0.78/0.7216 DF160/L 10 710 4.3 21/10.5 137/42 87/79 0.80/0.7522 DF180/LM 14 720 6 28/14.6 182/59 87/78 0.81/0.7724 DF180/L 17 720 7.3 34/17.8 221/71 87/78 0.84/0.7626 W200/LFG 18.6 720 8 38/22 266/99 89/82 0.78/0.6530 W200/LF 22 730 9.5 45/25 315/113 90/83 0.78/0.6536 W200/LFR 27 730 12 55/31 385/140 90/84 0.79/0.65

Page 49: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules:Two Speed (Full and Other Pole Change)

51

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

125JM/50/4-6/12/... 1470 8 D200/38 22.4 970 6.64 41.5/13.3 270/53 89/87 0.88/0.8312 D200/46 28.3 970 8.39 51.9/17.1 337/68 90/88 0.89/0.8414 W200/LF 31 960 10 57/24 370/132 90.8/85.3 0.86/0.7018 W200/LFR 38 960 12 70/29 455/160 91/85.5 0.86/0.7020 W225/M 47 970 15 86/35 602/210 92/87.5 0.86/0.7024 W225/MF 58 980 19 104/44 728/264 92.5/89 0.86/0.7032 W250/M 79 980 26 142/62 994/372 93.2/89.2 0.86/0.6836 W250/MF 95 985 31 171/74 1197/444 93.5/89.4 0.86/0.68

140JM/40/6-8/6/... 960 12 DF160/LM 7.5 710 3.2 16.2/8.2 105/32.8 85/78 0.78/0.7216 DF160/L 10 710 4.3 21/10.5 137/42 87/79 0.80/0.7520 DF180/LM 14 720 6 28/14.6 182/59 87/78 0.81/0.7724 DF180/L 17 720 7.3 34/17.8 221/71 87/78 0.84/0.7626 W200/LFG 18.6 720 8 38/22 266/99 89/82 0.78/0.6530 W200/LF 22 730 9.5 45/25 315/113 90/83 0.78/0.6536 W200/LFR 27 730 12 55/31 385/140 90/84 0.79/0.65

140JM/40/6-8/9/... 960 8 DF160/LM 7.5 710 3.2 16.2/8.2 105/32.8 85/78 0.78/0.7210 DF160/L 10 710 4.3 21/10.5 137/42 87/79 0.80/0.7516 DF180/LM 14 720 6 28/14.6 182/59 87/78 0.81/0.7718 DF180/L 17 720 7.3 34/17.8 221/71 87/78 0.84/0.7620 W200/LFG 18.6 720 8 38/22 266/99 89/82 0.78/0.6524 W200/LF 22 730 9.5 45/25 315/113 90/83 0.78/0.6530 W200/LFR 27 730 12 55/31 385/140 90/84 0.79/0.6532 W225/M 30 730 13 63/34 441/153 91/84 0.76/0.6536 W225/MF 37 730 18 77/42 539/189 91/84 0.76/0.65

140JM/50/4-6/9/... 1470 10 D200/46 28.3 970 8.39 51.9/17.1 337/68 90/88 0.89/0.8410 W200/LF 31 960 10 57/24 370/132 90.8/85.3 0.86/0.7014 W200/LFR 38 960 12 70/29 455/160 91/85.5 0.86/0.7016 W225/M 47 970 15 86/35 602/210 92/87.5 0.86/0.7020 W225/MF 58 980 19 104/44 728/264 92.5/89 0.86/0.7026 W250/M 79 980 26 142/62 994/372 93.2/89.2 0.86/0.6830 W250/MF 95 985 31 171/74 1197/444 93.5/89.4 0.86/0.68

140JM/50/6-8/12/... 960 8 DF160/L 10 710 4.3 21/10.5 137/42 87/79 0.80/0.7514 DF180/LM 14 720 6 28/14.6 182/59 87/78 0.81/0.7716 DF180/L 17 720 7.3 34/17.8 221/71 87/78 0.84/0.7618 W200/LFG 18.6 720 8 38/22 266/99 89/82 0.78/0.6522 W200/LF 22 730 9.5 45/25 315/113 90/83 0.78/0.6526 W200/LFR 27 730 12 55/31 385/140 90/84 0.79/0.6528 W225/M 30 730 13 63/34 441/153 91/84 0.76/0.6534 W225/MF 37 730 18 77/42 539/189 91/84 0.76/0.6536 W250/M 45 730 20 88/48 616/216 92/88 0.80/0.66

140JM/50/4-6/12/... 1470 8 W200/LF 31 960 10 57/24 370/132 90.8/85.3 0.86/0.7010 W200/LFR 38 960 12 70/29 455/160 91/85.5 0.86/0.7012 W225/M 47 970 15 86/35 602/210 92/87.5 0.86/0.7016 W225/MF 58 980 19 104/44 728/264 92.5/89 0.86/0.7022 W250/M 79 980 26 142/62 994/372 93.2/89.2 0.86/0.6826 W250/MF 95 985 31 171/74 1197/444 93.5/89.4 0.86/0.68

160JM/40/6-8/6/... 960 8 DF160/L 10 710 4.3 21/10.5 137/42 87/79 0.80/0.7512 DF180/LM 14 720 6 28/14.6 182/59 87/78 0.81/0.7714 DF180/L 17 720 7.3 34/17.8 221/71 87/78 0.84/0.7616 W200/LFG 18.6 720 8 38/22 266/99 89/82 0.78/0.6518 W200/LF 22 730 9.5 45/25 315/113 90/83 0.78/0.6524 W200/LFR 27 730 12 55/31 385/140 90/84 0.79/0.6526 W225/M 30 730 13 63/34 441/153 91/84 0.76/0.6530 W225/MF 37 730 18 77/42 539/189 91/84 0.76/0.6532 W250/M 45 730 20 88/48 616/216 92/88 0.80/0.66

Page 50: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules:Two Speed (Full and Other Pole Change)

52

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

160JM/40/6-8/9/... 960 8 DF180/LM 14 720 6 28/14.6 182/59 87/78 0.81/0.7710 DF180/L 17 720 7.3 34/17.8 221/71 87/78 0.84/0.7610 W200/LFG 18.6 720 8 38/22 266/99 89/82 0.78/0.6514 W200/LF 22 730 9.5 45/25 315/113 90/83 0.78/0.6518 W200/LFR 27 730 12 55/31 385/140 90/84 0.79/0.6520 W225/M 30 730 13 63/34 441/153 91/84 0.76/0.6524 W225/MF 37 730 18 77/42 539/189 91/84 0.76/0.6526 W250/M 45 730 20 88/48 616/216 92/88 0.80/0.6630 W250/MF 55 740 24 107/59 749/266 93/88 0.80/0.66

160JM/50/6-8/9/... 960 8 DF180/LM 14 720 6 28/14.6 182/59 87/78 0.81/0.7710 DF180/L 17 720 7.3 34/17.8 221/71 87/78 0.84/0.7612 W200/LFG 18.6 720 8 38/22 266/99 89/82 0.78/0.6514 W200/LF 22 730 9.5 45/25 315/113 90/83 0.78/0.6518 W200/LFR 27 730 12 55/31 385/140 90/84 0.79/0.6520 W225/M 30 730 13 63/34 441/153 91/84 0.76/0.6524 W225/MF 37 730 18 77/42 539/189 91/84 0.76/0.6526 W250/M 45 730 20 88/48 616/216 92/88 0.80/0.6630 W250/MF 55 740 24 107/59 749/266 93/88 0.80/0.66

160JM/50/6-8/12/... 960 8 W200/LFG 18.6 720 8 38/22 266/99 89/82 0.78/0.6510 W200/LF 22 730 9.5 45/25 315/113 90/83 0.78/0.6514 W200/LFR 27 730 12 55/31 385/140 90/84 0.79/0.6516 W225/M 30 730 13 63/34 441/153 91/84 0.76/0.6520 W225/MF 37 730 18 77/42 539/189 91/84 0.76/0.6524 W250/M 45 730 20 88/48 616/216 92/88 0.80/0.6626 W250/MF 55 740 24 107/59 749/266 93/88 0.80/0.66

Page 51: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules:Two Speed (Full and Other Dual Wound)

53

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

45JM/20/6-8/3/... 900 36 F2265 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.61

45JM/20/4-6/3/... 1420 36 F2265 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.75

45JM/20/6-8/6/... 900 40 F2265 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.61

45JM/20/4-6/6/... 1420 40 F2265 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.75

50JM/20/6-8/3/... 915 36 F2265 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.61

50JM/20/4-6/3/... 1420 36 F2265 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.75

50JM/20/6-8/6/... 915 40 F2265 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.61

50JM/20/4-6/6/... 1420 40 F2265 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.75

56JM/20/6-8/3/... 900 36 F2265 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.61

56JM/20/4-6/3/... 1420 36 F2265 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.75

56JM/20/6-8/6/... 900 40 F2265 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.61

56JM/20/4-6/6/... 1420 36 F2265 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.7540 F2269 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.69

63JM/20/6-8/3/... 900 36 F2265 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.61

63JM/20/4-6/3/... 1420 30 F2265 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.7536 F2269 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.69

63JM/20/6-8/6/... 900 34 F2265 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.6136 F2269 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.65

63JM/20/4-6/6/... 1420 22 F2265 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.7532 F2269 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.69

63JM/25/4-6/6/... 1440 26 F2265 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.7536 F2269 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.69

63JM/25/6-8/9/... 935 32 F2265 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.6140 F2269 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.65

63JM/25/4-6/9/... 1440 20 F2265 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.7530 F2269 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.6940 D132/21 4.5 970 1.34 11.2/4.2 74/24 80/65 0.73/0.70

71JM/20/6-8/3/... 900 32 F2265 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.6136 F2269 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.65

71JM/20/4-6/3/... 1440 20 F2265 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.7532 F2269 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.69

71JM/20/6-8/6/... 900 22 F2265 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.6136 F2269 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.65

71JM/20/4-6/6/... 1440 12 F2265 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.7520 F2269 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.69

Page 52: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules:Two Speed (Full and Other Dual Wound)

54

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

71JM/25/4-6/3/... 1440 24 F2265 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.7532 F2269 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.69

71JM/25/6-8/6/... 935 26 F2265 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.6136 F2269 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.65

71JM/25/4-6/6/... 1440 16 F2265 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.7526 F2269 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.6936 D132/21 4.5 970 1.34 11.2/4.2 74/24 80/65 0.73/0.70

71JM/25/6-8/9/... 935 20 F2265 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.6134 F2269 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.6536 D132/19 2.24 725 0.97 6.4/3.4 42/19 75/64 0.71/0.65

71JM/25/4-6/9/... 1440 8 F2265 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.7518 F2269 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.6932 D132/21 4.5 970 1.34 11.2/4.2 74/24 80/65 0.73/0.7036 D132/24 5.8 970 1.7 12.8/5.0 80/28 81/70 0.81/0.70

80JM/20/6-8/3/... 935 22 F2265 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.6136 F2269 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.65

80JM/20/4-6/3/... 1440 12 F2265 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.7522 F2269 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.69

80JM/20/6-8/6/... 935 12 F2265 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.6124 F2269 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.65

80JM/20/4-6/6/... 1440 12 F2269 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.69

80JM/25/6-8/3/... 935 26 F2265 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.6132 F2269 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.65

80JM/25/4-6/3/... 1440 16 F2265 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.7526 F2269 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.6932 D132/21 4.5 970 1.34 11.2/4.2 74/24 80/65 0.73/0.70

80JM/25/6-8/6/... 935 16 F2265 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.6128 F2269 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.6536 D132/19 2.24 725 0.97 6.4/3.4 42/19 75/64 0.71/0.65

80JM/25/4-6/6/... 1440 8 F2265 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.7516 F2269 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.6926 D132/21 4.5 970 1.34 11.2/4.2 74/24 80/65 0.73/0.7032 D132/24 5.8 970 1.7 12.8/5.0 80/28 81/70 0.81/0.7036 D160/27 8.21 970 2.61 16.2/5.2 113/34 85/75 0.86/0.82

80JM/25/6-8/9/... 935 10 F2265 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.6122 F2269 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.6532 D132/19 2.24 725 0.97 6.4/3.4 42/19 75/64 0.71/0.6536 D132/26 3.58 730 1.49 9.9/4.9 59/25 76/66 0.70/0.67

80JM/25/4-6/9/... 1440 10 F2269 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.6920 D132/21 4.5 970 1.34 11.2/4.2 74/24 80/65 0.73/0.7026 D132/24 5.8 970 1.7 12.8/5.0 80/28 81/70 0.81/0.7032 D160/27 8.21 970 2.61 16.2/5.2 113/34 85/75 0.86/0.8236 D160/34 11.2 970 3.36 21.3/7.4 149/48 86/78 0.88/0.84

Page 53: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules:Two Speed (Full and Other Dual Wound)

55

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

90JM/25/6-8/3/... 935 18 F2265 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.6128 F2269 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.6532 D132/19 2.24 725 0.97 6.4/3.4 42/19 75/64 0.71/0.65

90JM/25/4-6/3/... 1440 10 F2265 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.7516 F2269 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.6928 D132/21 4.5 970 1.34 11.2/4.2 74/24 80/65 0.73/0.7032 D132/24 5.8 970 1.7 12.8/5.0 80/28 81/70 0.81/0.70

90JM/25/6-8/6/... 935 18 F2269 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.6528 D132/19 2.24 725 0.97 6.4/3.4 42/19 75/64 0.71/0.6532 D132/26 3.58 730 1.49 9.9/4.9 59/25 76/66 0.70/0.67

90JM/25/4-6/6/... 1440 8 F2269 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.6918 D132/21 4.5 970 1.34 11.2/4.2 74/24 80/65 0.73/0.7022 D132/24 5.8 970 1.7 12.8/5.0 80/28 81/70 0.81/0.7028 D160/27 8.21 970 2.61 16.2/5.2 113/34 85/75 0.86/0.8232 D160/34 11.2 970 3.36 21.3/7.4 149/48 86/78 0.88/0.84

90JM/25/6-8/9/... 935 12 F2269 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.6520 D132/19 2.24 725 0.97 6.4/3.4 42/19 75/64 0.71/0.6530 D132/26 3.58 730 1.49 9.9/4.9 59/25 76/66 0.70/0.6736 D160/27 5.6 720 1.9 12.8/5.3 83/28 81/73 0.78/0.71

90JM/25/4-6/9/... 1440 10 D132/21 4.5 970 1.34 11.2/4.2 74/24 80/65 0.73/0.7016 D132/24 5.8 970 1.7 12.8/5.0 80/28 81/70 0.81/0.7020 D160/27 8.21 970 2.61 16.2/5.2 113/34 85/75 0.86/0.8228 D160/34 11.2 970 3.36 21.3/7.4 149/48 86/78 0.88/0.84

100JM/25/6-8/3/... 935 10 F2265 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.6120 F2269 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.6528 D132/19 2.24 725 0.97 6.4/3.4 42/19 75/64 0.71/0.6532 D132/26 3.58 730 1.49 9.9/4.9 59/25 76/66 0.70/0.67

100JM/25/4-6/3/... 1440 10 F2269 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.6920 D132/21 4.5 970 1.34 11.2/4.2 74/24 80/65 0.73/0.7024 D132/24 5.8 970 1.7 12.8/5.0 80/28 81/70 0.81/0.7030 D160/27 8.21 970 2.61 16.2/5.2 113/34 85/75 0.86/0.8232 D160/34 11.2 970 3.36 21.3/7.4 149/48 86/78 0.88/0.84

100JM/25/6-8/6/... 950 10 F2269 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.6518 D132/19 2.24 725 0.97 6.4/3.4 42/19 75/64 0.71/0.6528 D132/26 3.58 730 1.49 9.9/4.9 59/25 76/66 0.70/0.6732 D160/27 5.6 720 1.9 12.8/5.3 83/28 81/73 0.78/0.71

100JM/25/4-6/6/... 1450 10 D132/21 4.5 970 1.34 11.2/4.2 74/24 80/65 0.73/0.7014 D132/24 5.8 970 1.7 12.8/5.0 80/28 81/70 0.81/0.7020 D160/27 8.21 970 2.61 16.2/5.2 113/34 85/75 0.86/0.8226 D160/34 11.2 970 3.36 21.3/7.4 149/48 86/78 0.88/0.84

100JM/25/6-8/9/... 960 12 D132/19 2.24 725 0.97 6.4/3.4 42/19 75/64 0.71/0.6520 D132/26 3.58 730 1.49 9.9/4.9 59/25 76/66 0.70/0.6730 D160/27 5.6 720 1.9 12.8/5.3 83/28 81/73 0.78/0.7136 D160/34 8.2 720 3.5 20/10.4 130/54 82/73 0.72/0.67

100JM/25/4-6/9/... 1470 8 D132/24 5.8 970 1.7 12.8/5.0 80/28 81/70 0.81/0.7014 D160/27 8.21 970 2.61 16.2/5.2 113/34 85/75 0.86/0.8220 D160/34 11.2 970 3.36 21.3/7.4 149/48 86/78 0.88/0.84

Page 54: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules:Two Speed (Full and Other Dual Wound)

56

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

100JM/31/4-6/9/... 1470 8 D132/24 5.8 970 1.7 12.8/5.0 80/28 81/70 0.81/0.7014 D160/27 8.21 970 2.61 16.2/5.2 113/34 85/75 0.86/0.8218 D160/34 11.2 970 3.36 21.3/7.4 149/48 86/78 0.88/0.8422 D180/29 12.7 970 3.73 23.9/8.2 156/65 87/80 0.88/0.8226 D180/35 16.4 980 4.85 30/10.3 195/82 88/82 0.89/0.83

100JM/40/4-6/9/... 1470 10 D160/27 8.21 970 2.61 16.2/5.2 113/34 85/75 0.86/0.8216 D160/34 11.2 970 3.36 21.3/7.4 149/48 86/78 0.88/0.8418 D180/29 12.7 970 3.73 23.9/8.2 156/65 87/80 0.88/0.8222 D180/35 16.4 980 4.85 30/10.3 195/82 88/82 0.89/0.8326 D200/36 20.1 980 5.97 39.5/13.5 296/121 88/83 0.84/0.7734 D200/46 28.3 980 8.21 54/18.3 405/164 89/84 0.85/0.7736 W200/LFR 30 975 10 57/24 371/144 89.0/83.5 0.85/0.7240 W225/M 40 980 13 75/30 488/195 90.5/85 0.85/0.73

112JM/40/6-8/6/... 960 8 D132/19 2.24 725 0.97 6.4/3.4 42/19 75/64 0.71/0.6514 D132/26 3.58 730 1.49 9.9/4.9 59/25 76/66 0.70/0.6722 D160/27 5.6 720 1.9 12.8/5.3 83/28 81/73 0.78/0.7130 D160/34 8.2 720 3.5 20/10.4 130/54 82/73 0.72/0.6732 D160/38 10.5 720 4.4 22.5/10.6 124/44.5 82/77 0.82/0.78

112JM/40/4-6/6/... 1470 8 D160/27 8.21 970 2.61 16.2/5.2 113/34 85/75 0.86/0.8212 D160/34 11.2 970 3.36 21.3/7.4 149/48 86/78 0.88/0.8414 D180/29 12.7 970 3.73 23.9/8.2 156/65 87/80 0.88/0.8218 D180/35 16.4 980 4.85 30/10.3 195/82 88/82 0.89/0.8322 D200/36 20.1 980 5.97 39.5/13.5 296/121 88/83 0.84/0.7728 D200/46 28.3 980 8.21 54/18.3 405/164 89/84 0.85/0.7730 W200/LFR 30 975 10 57/24 371/144 89.0/83.5 0.85/0.7232 W225/M 40 980 13 75/30 488/195 90.5/85 0.85/0.73

112JM/40/6-8/9/... 960 8 D132/26 3.58 730 1.49 9.9/4.9 59/25 76/66 0.70/0.6718 D160/27 5.6 720 1.9 12.8/5.3 83/28 81/73 0.78/0.7124 D160/34 8.2 720 3.5 20/10.4 130/54 82/73 0.72/0.6730 D160/38 10.5 720 4.4 22.5/10.6 124/44.5 82/77 0.82/0.7830 D180/35 11.2 730 4.7 23.5/11.7 153/70 84/81 0.82/0.7236 D200/38 15 730 6.3 30.4/16 182/88 87/81 0.82/0.70

112JM/40/4-6/9/... 1470 8 D160/34 11.2 970 3.36 21.3/7.4 149/48 86/78 0.88/0.8410 D180/29 12.7 970 3.73 23.9/8.2 156/65 87/80 0.88/0.8214 D180/35 16.4 980 4.85 30/10.3 195/82 88/82 0.89/0.8318 D200/36 20.1 980 5.97 39.5/13.5 296/121 88/83 0.84/0.7724 D200/46 28.3 980 8.21 54/18.3 405/164 89/84 0.85/0.7724 W200/LFR 30 975 10 57/24 371/144 89.0/83.5 0.85/0.7230 W225/M 40 980 13 75/30 488/195 90.5/85 0.85/0.7334 W225/MF 49 980 16 90/37 585/241 91/86 0.86/0.73

112JM/50/6-8/12/... 960 16 D160/27 5.6 720 1.9 12.8/5.3 83/28 81/73 0.78/0.7122 D160/34 8.2 720 3.5 20/10.4 130/54 82/73 0.72/0.6728 D160/38 10.5 720 4.4 22.5/10.6 124/44.5 82/77 0.82/0.7828 D180/35 11.2 730 4.7 23.5/11.7 153/70 84/81 0.82/0.7234 D200/38 15 730 6.3 30.4/16 182/88 87/81 0.82/0.7036 W200/LFR 19 735 8.3 40/21 280/126 88.7/84.4 0.77/0.68

112JM/50/4-6/12/... 1470 8 D180/29 12.7 970 3.73 23.9/8.2 156/65 87/80 0.88/0.8212 D180/35 16.4 980 4.85 30/10.3 195/82 88/82 0.89/0.8316 D200/36 20.1 980 5.97 39.5/13.5 296/121 88/83 0.84/0.7722 D200/46 28.3 980 8.21 54/18.3 405/164 89/84 0.85/0.7724 W200/LFR 30 975 10 57/24 371/144 89.0/83.5 0.85/0.7228 W225/M 40 980 13 75/30 488/195 90.5/85 0.85/0.7332 W225/MF 49 980 16 90/37 585/241 91/86 0.86/0.7336 W250/M 66 985 22 121/50 787/325 91.5/87 0.86/0.73

Page 55: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules:Two Speed (Full and Other Dual Wound)

57

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

125JM/40/6-8/6/... 960 8 D132/26 3.58 730 1.49 9.9/4.9 59/25 76/66 0.70/0.6714 D160/27 5.6 720 1.9 12.8/5.3 83/28 81/73 0.78/0.7120 D160/34 8.2 720 3.5 20/10.4 130/54 82/73 0.72/0.6726 D160/38 10.5 720 4.4 22.5/10.6 124/44.5 82/77 0.82/0.7826 D180/35 11.2 730 4.7 23.5/11.7 153/70 84/81 0.82/0.7232 D200/38 15 730 6.3 30.4/16 182/88 87/81 0.82/0.70

125JM/40/4-6/6/... 1470 8 D160/34 11.2 970 3.36 21.3/7.4 149/48 86/78 0.88/0.848 D180/29 12.7 970 3.73 23.9/8.2 156/65 87/80 0.88/0.82

12 D180/35 16.4 980 4.85 30/10.3 195/82 88/82 0.89/0.8316 D200/36 20.1 980 5.97 39.5/13.5 296/121 88/83 0.84/0.7720 D200/46 28.3 980 8.21 54/18.3 405/164 89/84 0.85/0.7722 W200/LFR 30 975 10 57/24 371/144 89.0/83.5 0.85/0.7226 W225/M 40 980 13 75/30 488/195 90.5/85 0.85/0.7330 W225/MF 49 980 16 90/37 585/241 91/86 0.86/0.7332 W250/M 66 985 22 121/50 787/325 91.5/87 0.86/0.73

125JM/40/6-8/9/... 960 10 D160/27 5.6 720 1.9 12.8/5.3 83/28 81/73 0.78/0.7116 D160/34 8.2 720 3.5 20/10.4 130/54 82/73 0.72/0.6720 D160/38 10.5 720 4.4 22.5/10.6 124/44.5 82/77 0.82/0.7820 D180/35 11.2 730 4.7 23.5/11.7 153/70 84/81 0.82/0.7226 D200/38 15 730 6.3 30.4/16 182/88 87/81 0.82/0.7030 W200/LFR 19 735 8.3 40/21 280/126 88.7/84.4 0.77/0.6832 W225/M 22 735 9.5 48/24 336/192 89.4/86.2 0.74/0.6636 W225/MF 26 735 11.3 56/28 392/168 89.4/86.2 0.74/0.66

125JM/40/4-6/9/... 1470 10 D200/36 20.1 980 5.97 39.5/13.5 296/121 88/83 0.84/0.7716 D200/46 28.3 980 8.21 54/18.3 405/164 89/84 0.85/0.7716 W200/LFR 30 975 10 57/24 371/144 89.0/83.5 0.85/0.7220 W225/M 40 980 13 75/30 488/195 90.5/85 0.85/0.7324 W225/MF 49 980 16 90/37 585/241 91/86 0.86/0.7330 W250/M 66 985 22 121/50 787/325 91.5/87 0.86/0.7334 W250/MF 78 985 26 142/58 923/377 92/88 0.86/0.73

125JM/50/4-6/6/... 1470 8 D180/29 12.7 970 3.73 23.9/8.2 156/65 87/80 0.88/0.8212 D180/35 16.4 980 4.85 30/10.3 195/82 88/82 0.89/0.8314 D200/36 20.1 980 5.97 39.5/13.5 296/121 88/83 0.84/0.7720 D200/46 28.3 980 8.21 54/18.3 405/164 89/84 0.85/0.7722 W200/LFR 30 975 10 57/24 371/144 89.0/83.5 0.85/0.7226 W225/M 40 980 13 75/30 488/195 90.5/85 0.85/0.7330 W225/MF 49 980 16 90/37 585/241 91/86 0.86/0.7332 W250/M 66 985 22 121/50 787/325 91.5/87 0.86/0.73

125JM/50/4-6/9/... 1470 8 D180/35 16.4 980 4.85 30/10.3 195/82 88/82 0.89/0.8310 D200/36 20.1 980 5.97 39.5/13.5 296/121 88/83 0.84/0.7716 D200/46 28.3 980 8.21 54/18.3 405/164 89/84 0.85/0.7716 W200/LFR 30 975 10 57/24 371/144 89.0/83.5 0.85/0.7222 W225/M 40 980 13 75/30 488/195 90.5/85 0.85/0.7326 W225/MF 49 980 16 90/37 585/241 91/86 0.86/0.7330 W250/M 66 985 22 121/50 787/325 91.5/87 0.86/0.7334 W250/MF 78 985 26 142/58 923/377 92/88 0.86/0.73

125JM/50/6-8/12/... 960 14 D160/34 8.2 720 3.5 20/10.4 130/54 82/73 0.72/0.6718 D160/38 10.5 720 4.4 22.5/10.6 124/44.5 82/77 0.82/0.7818 D180/35 11.2 730 4.7 23.5/11.7 153/70 84/81 0.82/0.7222 D200/38 15 730 6.3 30.4/16 182/88 87/81 0.82/0.7026 W200/LFR 19 735 8.3 40/21 280/126 88.7/84.4 0.77/0.6830 W225/M 22 735 9.5 48/24 336/192 89.4/86.2 0.74/0.6634 W225/MF 26 735 11.3 56/28 392/168 89.4/86.2 0.74/0.6636 W250/M 38 735 15.4 73/36 511/216 91.2/88.9 0.78/0.69

Page 56: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules:Two Speed (Full and Other Dual Wound)

58

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

125JM/50/4-6/12/... 1470 12 D200/46 28.3 980 8.21 54/18.3 405/164 89/84 0.85/0.7714 W200/LFR 30 975 10 57/24 371/144 89.0/83.5 0.85/0.7218 W225/M 40 980 13 75/30 488/195 90.5/85 0.85/0.7322 W225/MF 49 980 16 90/37 585/241 91/86 0.86/0.7326 W250/M 66 985 22 121/50 787/325 91.5/87 0.86/0.7330 W250/MF 78 985 26 142/58 923/377 92/88 0.86/0.73

140JM/40/6-8/6/... 960 8 D160/27 5.6 720 1.9 12.8/5.3 83/28 81/73 0.78/0.7114 D160/34 8.2 720 3.5 20/10.4 130/54 82/73 0.72/0.6718 D160/38 10.5 720 4.4 22.5/10.6 124/44.5 82/77 0.82/0.7818 D180/35 11.2 730 4.7 23.5/11.7 153/70 84/81 0.82/0.7222 D200/38 15 730 6.3 30.4/16 182/88 87/81 0.82/0.7026 W200/LFR 19 735 8.3 40/21 280/126 88.7/84.4 0.77/0.6830 W225/M 22 735 9.5 48/24 336/192 89.4/86.2 0.74/0.6634 W225/MF 26 735 11.3 56/28 392/168 89.4/86.2 0.74/0.6636 W250/M 38 735 15.4 73/36 511/216 91.2/88.9 0.78/0.69

140JM/40/6-8/9/... 960 8 D160/34 8.2 720 3.5 20/10.4 130/54 82/73 0.72/0.6712 D160/38 10.5 720 4.4 22.5/10.6 124/44.5 82/77 0.82/0.7812 D180/35 11.2 730 4.7 23.5/11.7 153/70 84/81 0.82/0.7218 D200/38 15 730 6.3 30.4/16 182/88 87/81 0.82/0.7020 W200/LFR 19 735 8.3 40/21 280/126 88.7/84.4 0.77/0.6824 W225/M 22 735 9.5 48/24 336/192 89.4/86.2 0.74/0.6626 W225/MF 26 735 11.3 56/28 392/168 89.4/86.2 0.74/0.6636 W250/M 38 735 15.4 73/36 511/216 91.2/88.9 0.78/0.69

140JM/50/4-6/9/... 1470 10 D200/46 28.3 980 8.21 54/18.3 405/164 89/84 0.85/0.7710 W200/LFR 30 975 10 57/24 371/144 89.0/83.5 0.85/0.7214 W225/M 40 980 13 75/30 488/195 90.5/85 0.85/0.7318 W225/MF 49 980 16 90/37 585/241 91/86 0.86/0.7322 W250/M 66 985 22 121/50 787/325 91.5/87 0.86/0.7326 W250/MF 78 985 26 142/58 923/377 92/88 0.86/0.73

140JM/50/6-8/12/... 960 10 D160/38 10.5 720 4.4 22.5/10.6 124/44.5 82/77 0.82/0.7810 D180/35 11.2 730 4.7 23.5/11.7 153/70 84/81 0.82/0.7214 D200/38 15 730 6.3 30.4/16 182/88 87/81 0.82/0.7018 W200/LFR 19 735 8.3 40/21 280/126 88.7/84.4 0.77/0.6820 W225/M 22 735 9.5 48/24 336/192 89.4/86.2 0.74/0.6624 W225/MF 26 735 11.3 56/28 392/168 89.4/86.2 0.74/0.6632 W250/M 38 735 15.4 73/36 511/216 91.2/88.9 0.78/0.6934 W250/MF 40 735 17.3 81/41 567/246 91.7/88.2 0.79/0.69

140JM/50/4-6/12/... 1470 10 W225/M 40 980 13 75/30 488/195 90.5/85 0.85/0.7314 W225/MF 49 980 16 90/37 585/241 91/86 0.86/0.7318 W250/M 66 985 22 121/50 787/325 91.5/87 0.86/0.7322 W250/MF 78 985 26 142/58 923/377 92/88 0.86/0.73

160JM/40/6-8/6/... 960 8 D160/38 10.5 720 4.4 22.5/10.6 124/44.5 82/77 0.82/0.788 D180/35 11.2 730 4.7 23.5/11.7 153/70 84/81 0.82/0.72

14 D200/38 15 730 6.3 30.4/16 182/88 87/81 0.82/0.7016 W200/LFR 19 735 8.3 40/21 280/126 88.7/84.4 0.77/0.6818 W225/M 22 735 9.5 48/24 336/192 89.4/86.2 0.74/0.6622 W225/MF 26 735 11.3 56/28 392/168 89.4/86.2 0.74/0.6628 W250/M 38 735 15.4 73/36 511/216 91.2/88.9 0.78/0.6930 W250/MF 40 735 17.3 81/41 567/246 91.7/88.2 0.79/0.69

160JM/40/6-8/9/... 960 8 D200/38 15 730 6.3 30.4/16 182/88 87/81 0.82/0.7012 W200/LFR 19 735 8.3 40/21 280/126 88.7/84.4 0.77/0.6814 W225/M 22 735 9.5 48/24 336/192 89.4/86.2 0.74/0.6616 W225/MF 26 735 11.3 56/28 392/168 89.4/86.2 0.74/0.6622 W250/M 38 735 15.4 73/36 511/216 91.2/88.9 0.78/0.6924 W250/MF 40 735 17.3 81/41 567/246 91.7/88.2 0.79/0.69

Page 57: JM Aerofoil 50 Hz Technical

JM AEROFOILMotor Frame Size Schedules:Two Speed (Full and Other Dual Wound)

59

400 V / 50 Hz / 3 φ

rev/min (kW)

Low SpeedSpeed

rev/min

Max. Pitch

Angle (°)Motor

Motor Rating(kW)

Full LoadCurrent

(A)

StartingCurrent

d.o.l. (A)

Efficiency

%

PowerFactorcos Ø

Code

160JM/50/6-8/9/... 960 8 D200/38 15 730 6.3 30.4/16 182/88 87/81 0.82/0.7012 W200/LFR 19 735 8.3 40/21 280/126 88.7/84.4 0.77/0.6814 W225/M 22 735 9.5 48/24 336/192 89.4/86.2 0.74/0.6616 W225/MF 26 735 11.3 56/28 392/168 89.4/86.2 0.74/0.6622 W250/M 38 735 15.4 73/36 511/216 91.2/88.9 0.78/0.6924 W250/MF 40 735 17.3 81/41 567/246 91.7/88.2 0.79/0.69

160JM/50/6-8/12/... 960 8 W200/LFR 19 735 8.3 40/21 280/126 88.7/84.4 0.77/0.6810 W225/M 22 735 9.5 48/24 336/192 89.4/86.2 0.74/0.6612 W225/MF 26 735 11.3 56/28 392/168 89.4/86.2 0.74/0.6620 W250/M 38 735 15.4 73/36 511/216 91.2/88.9 0.78/0.6920 W250/MF 40 735 17.3 81/41 567/246 91.7/88.2 0.79/0.69

Page 58: JM Aerofoil 50 Hz Technical

Fan Code: 31JM/16/6/5/...315 mm 900 rev/min 5 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11685

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.1 0.2 0.3 0.4 0.50

10

20

30

40

50

600 500 1000 1500

0 200 400 600 800 1000

0

1

2

3

4

5

6

0.00

0.05

0.10

0.15

0.20

0.0 0.1 0.2 0.3 0.4 0.50.000

0.005

0.010

0.015

0.020

0.025

16¡

24°

32°

40°

8° 16¡°24¡°

32°

40°

58

56

60

60

56

58

60

59

59

63

62

60

60

61

67

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—4—8

—5—9

—6—3

—14—8

—21–15

—27—22

—33—30

—40—38

8—1—5

—3—8

—6—3

—14—8

—20—15

—26—21

—33—28

—40—36

16—4—4

—7—7

—5—6

—12—10

—17—13

—25—18

—30—24

—38—30

16—1—1

—6—6

—5—6

—12—10

—17—13

—24—17

—30—24

—38—30

24 — 40—2—3

—7—8

—8—8

—14—11

—16—15

—22—20

—25—25

—30—31

01

—7—6

—8—8

—13—11

—15—15

—20—20

—24—24

—28—30

24 — 40

JM AEROFOIL

Page 59: JM Aerofoil 50 Hz Technical

Fan Code: 31JM/16/4/5/...315 mm 1420 rev/min 5 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11686

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.80

20

40

60

80

100

120

1400 500 1000 1500 2000 2500

0 200 400 600 800 1000 1200 1400 1600

0

2

4

6

8

10

12

14

0.0

0.1

0.2

0.3

0.4

0.5

0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.80.000.010.020.030.040.050.060.070.080.09

16°

24°

32°

40°

8° 16°24°

32°

40°

68

66

70

70

67

70

71

70

70

73

72

72

70

72

77

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—7

—12—5—8

—5—8

—8—3

—17—11

—23—17

—30—25

—36—32

8—5

—11—3—5

—4—8

—8—3

—17—11

—22—17

—30—23

—35—30

16—11—10

—4—5

—9—7

—5—6

—14—11

—20—14

—27—21

—33—26

16—9—8

—1—2

—8—7

—5—6

—13—11

—19—14

—27—21

—33—26

24 — 40 24 — 40 —3—6

—6—4

—9—9

—11—9

—16—13

—20—17

—25—23

—29—28

—2—4

—4—1

—9—8

—11—9

—15—13

—18—16

—23—22

—27—27

JM AEROFOIL

Page 60: JM Aerofoil 50 Hz Technical

Fan Code: 31JM/16/2/5/...315 mm 2840 rev/min 5 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11687

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.60

100

200

300

400

5000 1000 2000 3000 4000 5000

0 500 1000 1500 2000 2500 3000

0

10

20

30

40

50

0.0

0.5

1.0

1.5

2.0

0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.60.00.10.20.30.40.50.60.7

16°

24°

32°

40°

8° 16°24°

32°

40°

83

82

86

85

82

85

86

86

86

89

88

87

85

87

92

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—12—16

—7—13

—6—8

—5—8

—9—3

—17—11

—24—17

—30—25

8—10—14

—7—12

—3—6

—4—8

—8—3

—16—11

—24—16

—29—23

16—14—15

—11—10

—4—5

—9—7

—5—7

—14—11

—20—15

—27—21

16—13—13

—11—10

—1—2

—8—7

—5—6

—13—11

—20—15

—27—21

24 — 40 24 — 40—9—9

—4—7

—6—5

—10—10

—12—10

—17—14

—20—18

—25—23

—7—7

—4—6

—5—1

—9—9

—11—10

—15—13

—18—16

—23—22

JM AEROFOIL

Page 61: JM Aerofoil 50 Hz Technical

Fan Code: 35JM/16/6/5/...355 mm 900 rev/min 5 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11688

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.80

10

20

30

40

50

60

700 500 1000 1500 2000 2500

0 200 400 600 800 1000 1200 1400 1600

0

1

2

3

4

5

6

7

0.00

0.05

0.10

0.15

0.20

0.25

0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.80.0000.0050.0100.0150.0200.0250.0300.0350.040

16°

24°

32°

40°

8° 16°24°

32°

40°

60

59

63

61

59

59

64

62

63

65

66

64

62

66

65

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—6

—10—6—9

—4—3

—10—7

—18—14

—25—19

—32—28

—41—35

8—3—8

—5—8

—4—3

—10—7

—18—14

—24—19

—32—27

—40—33

16—6—6

—7—7

—4—6

—12—8

—14—11

—19—15

—25—22

—30—26

16—3—3

—6—7

—4—6

—12—8

—13—11

—18—14

—25—22

—30—26

24 — 4024 — 4024 — 4024 — 40—4—4

—6—7

—6—6

—11—11

—16—14

—21—18

—25—25

—32—30

—2—1

—6—6

—6—6

—11—11

—15—14

—19—18

—24—24

—30—29

JM AEROFOIL

Page 62: JM Aerofoil 50 Hz Technical

Fan Code: 35JM/16/4/5/...355 mm 1420 rev/min 5 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11689

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.2 0.4 0.6 0.8 1.0 1.20

20

40

60

80

100

120

140

1600 500 1000 1500 2000 2500 3000 3500 4000

0 500 1000 1500 2000 2500

0

2

4

6

8

10

12

14

16

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.0 0.2 0.4 0.6 0.8 1.0 1.20.000.020.040.060.080.100.120.140.16

16°

24°

32°

40°

8° 16°24°

32°

40°

70

69

73

71

70

70

74

72

74

76

76

75

72

76

76

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—9

—14—7

—10—5—7

—5—3

—13—10

—20—16

—27—22

—35—31

8—6

—12—5—8

—4—7

—5—3

—13—9

—20—16

—27—20

—35—29

16—12—10

—6—6

—6—7

—5—6

—13—9

—15—12

—21—17

—27—24

16—10

—9—3—3

—6—6

—5—6

—12—9

—14—12

—21—17

—27—24

24 — 4024 — 40 24 — 4024 — 40—5—7

—6—5

—7—8

—8—7

—14—12

—18—16

—23—21

—28—27

—3—5

—5—2

—7—7

—7—7

—13—12

—17—16

—21—20

—26—26

JM AEROFOIL

Page 63: JM Aerofoil 50 Hz Technical

Fan Code: 35JM/16/2/5/...355 mm 2840 rev/min 5 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11690

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.5 1.0 1.5 2.0 2.50

100

200

300

400

500

600

7000 2000 4000 6000 8000

0 1000 2000 3000 4000 5000

0

10

20

30

40

50

60

70

0.0

0.5

1.0

1.5

2.0

2.5

0.0 0.5 1.0 1.5 2.0 2.50.0

0.2

0.4

0.6

0.8

1.0

1.2

16°

24°

32°

40°

8° 16°24°

32°

40°

85

84

88

87

85

86

90

88

90

92

92

91

87

91

91

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—13—17

—9—14

—7—10

—5—7

—6—3

—13—10

—21—16

—28—22

8—10—15

—8—14

—5—8

—4—7

—5—3

—12—9

—21—15

—27—20

16—12—11

—12—11

—6—7

—7—7

—5—7

—13—10

—16—13

—22—17

16—11—10

—12—11

—3—4

—6—7

—5—6

—12—9

—16—13

—21—17

24 — 40 24 —— 40—8—8

—6—8

—7—6

—8—8

—9—8

—14—13

—19—17

—24—22

—6—5

—5—7

—6—3

—7—8

—8—8

—13—13

—17—16

—22—21

JM AEROFOIL

Page 64: JM Aerofoil 50 Hz Technical

Fan Code: 40JM/16/6/5/...400 mm 900 rev/min 5 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11691

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.2 0.4 0.6 0.8 1.0 1.20

10

20

30

40

50

60

70

800 500 1000 1500 2000 2500 3000 3500 4000

0 500 1000 1500 2000 2500

0

1

2

3

4

5

6

7

8

0.00

0.05

0.10

0.15

0.20

0.25

0.30

0.0 0.2 0.4 0.6 0.8 1.0 1.20.000.010.020.030.040.050.060.07

16°

24°

32°

40°

8° 16°24°

32°

40°

63

61

64

64

63

63

67

65

65

69

69

68

64

67

68

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—6—9

—7—9

—4—5

—8—5

—15—11

—22—16

—30—24

—38—31

8—4—6

—6—8

—4—5

—8—5

—15—11

—21—16

—30—23

—38—29

16—5—4

—6—7

—7—8

—9—9

—12—11

—17—14

—24—20

—30—24

16—2—1

—5—6

—7—8

—9—9

—11—11

—16—13

—24—20

—30—24

24 — 40 24 — 40—3—3

—7—7

—8—8

—11—11

—14—14

—18—17

—23—23

—28—28

—10

—6—6

—8—8

—10—11

—13—14

—16—17

—21—22

—26—27

JM AEROFOIL

Page 65: JM Aerofoil 50 Hz Technical

JM AEROFOILFan Code: 40JM/16/4/5/...400 mm 1420 rev/min 5 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11692

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.80

50

100

150

2000 1000 2000 3000 4000 5000 6000

0 500 1000 1500 2000 2500 3000 3500

0

5

10

15

20

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.80.00

0.05

0.10

0.15

0.20

0.25

0.30

73

16°

24°

32°

40°

8° 16°24°

32°

40°

71

74

75

73

74

77

76

77

80

80

79

74

77

78

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—10—13

—7—9

—6—7

—5—4

—11—8

—18—13

—25—19

—33—26

8—7

—11—5—6

—5—7

—5—4

—11—8

—17—13

—25—17

—32—24

16—10—10

—4—5

—7—7

—7—8

—11—10

—14—12

—20—16

—26—22

16—8—8

—2—2

—7—7

—7—8

—10—9

—13—12

—20—16

—26—22

24 — 40 24 — 40—4—6

—6—5

—8—8

—9—9

—14—12

—17—15

—21—20

—26—26

—3—4

—4—2

—8—7

—9—9

—13—12

—15—15

—19—19

—24—25

JM AEROFOIL

Page 66: JM Aerofoil 50 Hz Technical

Fan Code: 40JM/16/2/5/...400 mm 2840 rev/min 5 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11693

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.50

100

200

300

400

500

600

700

8000 2000 4000 6000 8000 10000 12000

0 1000 2000 3000 4000 5000 6000 7000

0

10

20

30

40

50

60

70

80

0.0

0.5

1.0

1.5

2.0

2.5

3.0

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.50.0

0.5

1.0

1.5

2.0

2.5

16°

24°

32°

40°

8° 16°24°

32°

40°

88

86

90

90

89

89

93

92

92

96

96

95

89

92

94

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—14—16

—10—14

—8—9

—7—8

—5—5

—12—8

—19—14

—26—19

8—11—14

—9—13

—5—6

—5—7

—5—4

—10—7

—19—12

—25—17

16—12—12

—11—11

—5—5

—8—8

—8—9

—11—10

—15—13

—21—17

16—10—10

—10—10

—2—2

—7—7

—6—8

—10—10

—14—12

—20—16

24 — 40 24 — 40—8—8

—5—7

—7—6

—9—9

—11—10

—15—13

—18—17

—22—21

—6—6

—5—7

—5—2

—8—8

—9—10

—13—13

—16—15

—20—20

JM AEROFOIL

Page 67: JM Aerofoil 50 Hz Technical

Fan Code: 45JM/16/6/5/...450 mm 900 rev/min 5 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11694

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.60

10

20

30

40

50

60

70

80

900 1000 2000 3000 4000 5000

0 500 1000 1500 2000 2500 3000

0

2

4

6

8

0.00

0.05

0.10

0.15

0.20

0.25

0.30

0.35

0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.60.00

0.02

0.04

0.06

0.08

0.10

0.12

16°

24°

32°

40°

8°16°

24°

32°

40°

66

65

66

68

67

66

70

69

68

74

72

72

67

68

72

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—6—7

—8—9

—4—8

—7—5

—13—9

—20—14

—28—20

—36—26

8—4—6

—8—9

—4—8

—7—5

—13—9

—20—13

—27—20

—34—25

16—4—3

—7—7

—8—10

—8—10

—11—11

—16—14

—23—19

—30—22

16—4—2

—7—8

—8—10

—8—10

—11—11

—16—14

—22—18

—28—20

24 — 40 24 — 40—3—3

—7—7

—11—10

—11—11

—14—14

—16—16

—21—22

—24—27

—2—2

—7—7

—11—10

—11—11

—14—14

—16—16

—21—21

—23—25

JM AEROFOIL

Page 68: JM Aerofoil 50 Hz Technical

Fan Code: 45JM/20/6/3/...450 mm 900 rev/min 3 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11695

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.40

10

20

30

40

50

60

700 1000 2000 3000 4000

0 500 1000 1500 2000 2500

0

1

2

3

4

5

6

7

0.00

0.05

0.10

0.15

0.20

0.25

0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.40.000.010.020.030.040.050.060.070.08

16°

24°

32°

8°16°

24°

32°

64

62

63

66

64

65

69

67

68

63

63

72

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—15—10

—9—8

—3—5

—5—6

—14—11

—23—14

—32—20

—42—24

8—13

—7—9—8

—3—5

—5—6

—13—11

—22—13

—31—18

—40—22

16—8—6

—6—7

—4—5

—9—8

—14—12

—17—16

—23—22

—28—27

16—7—4

—5—7

—4—5

—9—8

—13—12

—17—15

—22—22

—27—26

24 — 36 24 — 36—5—4

—5—6

—8—7

—10—10

—13—13

—17—17

—21—24

—25—29

—3—2

—5—5

—8—7

—10—10

—13—13

—16—16

—19—23

—22—27

JM AEROFOIL

Page 69: JM Aerofoil 50 Hz Technical

Fan Code: 45JM/20/6/6/...450 mm 900 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11696

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.60

20

40

60

80

1000 1000 2000 3000 4000 5000

0 500 1000 1500 2000 2500 3000

0

2

4

6

8

10

0.00

0.05

0.10

0.15

0.20

0.25

0.30

0.35

0.40

0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.60.000.020.040.060.080.100.120.14

16°

24°

32°

40°

8° 16°24°

32°

40°

66

64

66

67

66

65

70

68

67

73

71

70

68

72

72

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—13—15

—10—10

—3—5

—5—4

—13—10

—22—15

—32—24

—42—31

8—11—14

—8—8

—3—5

—5—4

—13—10

—21—15

—32—23

—41—29

16—10—11

—6—6

—4—5

—8—7

—11—10

—16—13

—24—20

—29—24

16—9

—10—5—5

—4—5

—8—7

—11—10

—15—13

—24—20

—29—23

24 — 40 24 — 40—6—7

—6—6

—5—6

—9—8

—13—12

—16—15

—21—23

—26—28

—5—5

—5—4

—5—6

—9—8

—12—12

—15—15

—20—22

—25—27

JM AEROFOIL

Page 70: JM Aerofoil 50 Hz Technical

Fan Code: 45JM/16/4/5/...450 mm 1420 rev/min 5 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11697

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.5 1.0 1.5 2.0 2.50

50

100

150

200

2500 2000 4000 6000 8000

0 1000 2000 3000 4000 5000

0

5

10

15

20

25

0.0

0.2

0.4

0.6

0.8

1.0

0.0 0.5 1.0 1.5 2.0 2.50.0

0.1

0.2

0.3

0.4

0.5

16°

24°

32°

40°

8°16°

24°

32°

40°

76

75

76

79

78

77

81

80

80

85

84

84

77

78

82

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—11—13

—7—7

—8—9

—4—5

—9—6

—16—11

—23—16

—31—22

8—10—13

—5—6

—7—9

—4—5

—9—6

—16—9

—22—16

—29—21

16—9

—10—4—3

—9—9

—7—10

—9—11

—13—12

—19—16

—26—20

16—8

—10—4—3

—9—9

—7—10

—9—11

—13—12

—18—15

—24—18

24 — 40 24 — 40—4—6

—5—4

—9—8

—11—11

—15—13

—16—15

—20—20

—24—25

—3—5

—5—4

—9—8

—11—11

—15—13

—16—15

—19—19

—23—23

JM AEROFOIL

Page 71: JM Aerofoil 50 Hz Technical

Fan Code: 45JM/20/4/3/...450 mm 1420 rev/min 3 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11698

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.5 1.0 1.5 2.00

20

40

60

80

100

120

140

160

1800 1000 2000 3000 4000 5000 6000 7000

0 500 1000 1500 2000 2500 3000 3500 4000

0

5

10

15

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.0 0.5 1.0 1.5 2.00.00

0.05

0.10

0.15

0.20

0.25

0.30

16°

24°

32°

8°16°

24°

32°

74

72

74

77

75

76

80

78

79

73

73

82

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—16—10

—15—11

—6—6

—3—6

—8—7

—17—12

—25—15

—36—21

8—13

—8—14—11

—6—6

—3—6

—8—7

—16—12

—24—13

—33—19

16—8—6

—7—8

—5—6

—7—7

—12—10

—16—14

—20—17

—26—24

16—6—4

—6—8

—5—6

—7—7

—12—10

—15—14

—19—17

—25—23

24 — 36 24 — 36—4—4

—7—9

—6—6

—10—9

—12—11

—16—15

—19—20

—23—26

—3—1

—7—9

—6—6

—10—9

—12—11

—15—15

—17—18

—21—24

JM AEROFOIL

Page 72: JM Aerofoil 50 Hz Technical

Fan Code: 45JM/20/4/6/...450 mm 1420 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11699

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.5 1.0 1.5 2.0 2.50

50

100

150

200

2500 2000 4000 6000 8000

0 1000 2000 3000 4000 5000

0

5

10

15

20

25

0.0

0.2

0.4

0.6

0.8

1.0

0.0 0.5 1.0 1.5 2.0 2.50.0

0.1

0.2

0.3

0.4

0.5

0.6

16°

24°

32°

40°

8° 16°24°

32°

40°

77

75

76

78

76

76

80

78

78

84

82

81

78

82

82

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—17—19

—12—13

—6—6

—4—5

—7—5

—17—13

—24—17

—36—26

8—15—17

—10—11

—6—6

—4—5

—7—5

—16—12

—24—16

—34—25

16—14—15

—6—7

—4—5

—8—7

—9—8

—13—12

—18—14

—26—22

16—13—14

—5—5

—4—5

—8—7

—9—8

—13—12

—18—14

—25—21

24 — 40 24 — 40—7—9

—6—6

—6—6

—9—9

—11—9

—15—14

—19—17

—24—25

—5—6

—5—3

—6—6

—9—9

—10—9

—14—14

—17—16

—22—24

JM AEROFOIL

Page 73: JM Aerofoil 50 Hz Technical

Fan Code: 45JM/16/2/5/...450 mm 2840 rev/min 5 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11700

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 50

100

200

300

400

500

600

700

800

9000 5000 10000 15000

0 2000 4000 6000 8000 10000

0

20

40

60

80

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

0 1 2 3 4 50.00.51.01.52.02.53.03.54.0

16°

24°

32°

40°

8°16°

24°

32°

40°

92

90

92

94

93

93

96

95

96

101

100

100

92

94

97

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—15—15

—11—14

—7—8

—8—9

—5—6

—10—7

—17—11

—24—16

8—14—15

—11—14

—5—6

—7—9

—4—6

—9—5

—15—10

—21—15

16—12—13

—9—10

—5—3

—9—9

—8—11

—9—11

—13—13

—19—16

16—11—12

—9—10

—5—3

—9—9

—8—10

—9—11

—12—12

—18—14

24 — 40 24 — 40—8—9

—5—6

—6—5

—10—9

—12—12

—15—14

—17—16

—20—21

—7—8

—5—6

—6—5

—9—9

—12—11

—15—14

—16—15

—19—19

JM AEROFOIL

Page 74: JM Aerofoil 50 Hz Technical

Fan Code: 45JM/20/2/3/...450 mm 2910 rev/min 3 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11701

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.50

100

200

300

400

500

600

700

8000 2000 4000 6000 8000 10000 12000 14000

0 2000 4000 6000 8000

0

10

20

30

40

50

60

70

80

0.0

0.5

1.0

1.5

2.0

2.5

3.0

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.50.0

0.5

1.0

1.5

2.0

2.5

16°

24°

32°

8°16°

24°

32°

90

88

90

93

91

92

96

94

95

89

89

97

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—19—16

—16—10

—15—11

—6—6

—4—6

—8—7

—18—13

—26—15

8—16—14

—14—8

—14—11

—6—6

—3—6

—7—6

—16—11

—23—13

16—10—12

—8—7

—7—9

—5—6

—8—8

—12—10

—16—15

—20—18

16—8

—11—6—4

—7—8

—5—6

—7—8

—12—10

—15—14

—19—17

24 — 3624 — 36 24 — 3624 — 36—8

—10—5—4

—8—10

—7—7

—11—10

—13—12

—17—16

—20—20

—7—8

—4—2

—8—9

—7—7

—11—10

—12—11

—15—15

—17—18

JM AEROFOIL

Page 75: JM Aerofoil 50 Hz Technical

Fan Code: 45JM/20/2/6/...450 mm 2910 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11702

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 50

200

400

600

800

10000 5000 10000 15000

0 2000 4000 6000 8000 10000

0

20

40

60

80

100

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

0 1 2 3 4 50.00.51.01.52.02.53.03.54.04.5

16°

24°

32°

40°

8° 16°24°

32°

40°

92

90

92

93

92

92

96

95

94

100

98

97

94

97

98

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—17—18

—17—19

—13—13

—6—7

—4—5

—8—5

—17—13

—25—18

8—14—16

—16—19

—11—11

—5—6

—4—5

—7—4

—16—12

—23—16

16—11—13

—14—15

—7—8

—5—6

—8—7

—9—8

—14—12

—18—15

16—10—11

—14—15

—5—6

—4—5

—8—7

—9—8

—13—12

—18—14

24 — 40 24 — 40—8—8

—8—9

—7—6

—7—7

—10—10

—11—10

—16—15

—19—18

—7—6

—7—9

—6—4

—6—6

—9—9

—10—10

—14—14

—18—17

JM AEROFOIL

Page 76: JM Aerofoil 50 Hz Technical

Fan Code: 50JM/16/6/5/...500 mm 915 rev/min 5 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11703

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.5 1.0 1.5 2.0 2.50

20

40

60

80

100

1200 2000 4000 6000 8000

0 1000 2000 3000 4000 5000

0

2

4

6

8

10

12

0.0

0.1

0.2

0.3

0.4

0.0 0.5 1.0 1.5 2.0 2.50.00

0.05

0.10

0.15

0.20

0.25

16°

24°

32°

40°

8° 16°24°

32°

40°

70

69

70

72

72

71

74

74

73

78

77

76

70

70

72

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—9—7

—10—10

—4—7

—6—5

—11—8

—19—13

—26—19

—34—24

8—7—6

—9—10

—4—7

—6—5

—12—8

—19—12

—26—18

—32—22

16—7—3

—9—8

—5—9

—6—10

—10—12

—16—14

—23—18

—29—21

16—6—3

—9—8

—5—9

—6—10

—10—12

—16—14

—22—18

—28—20

24 — 40 24 — 40—3—3

—8—7

—9—9

—10—11

—13—14

—15—17

—19—22

—22—26

—2—2

—8—7

—9—9

—10—11

—13—14

—15—17

—19—21

—21—24

JM AEROFOIL

Page 77: JM Aerofoil 50 Hz Technical

Fan Code: 50JM/20/6/3/...500 mm 915 rev/min 3 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11704

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.5 1.0 1.5 2.00

10

20

30

40

50

60

70

800 1000 2000 3000 4000 5000 6000 7000

0 500 1000 1500 2000 2500 3000 3500 4000

0

1

2

3

4

5

6

7

8

0.00

0.05

0.10

0.15

0.20

0.25

0.30

0.0 0.5 1.0 1.5 2.00.000.020.040.060.080.100.120.14

16°

24°

32°

8°16°

24°

32°

68

66

68

68

66

68

73

71

72

66

66

75

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—16

—8—10

—7—4—6

—4—6

—13—11

—21—13

—30—18

—41—23

8—13

—5—9—7

—4—6

—4—6

—13—11

—21—13

—29—16

—39—20

16—8—5

—5—6

—5—6

—9—9

—14—13

—18—17

—22—22

—27—26

16—6—3

—5—6

—5—6

—9—9

—14—13

—17—16

—21—21

—26—25

24 — 36 24 — 36—5—4

—5—6

—8—8

—9—10

—13—14

—17—18

—20—23

—25—28

—3—1

—5—6

—8—8

—9—10

—13—14

—15—17

—18—22

—22—26

JM AEROFOIL

Page 78: JM Aerofoil 50 Hz Technical

Fan Code: 50JM/20/6/6/...500 mm 915 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11705

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.5 1.0 1.5 2.0 2.50

20

40

60

80

100

1200 2000 4000 6000 8000

0 1000 2000 3000 4000 5000

0

2

4

6

8

10

12

0.0

0.1

0.2

0.3

0.4

0.0 0.5 1.0 1.5 2.0 2.50.00

0.05

0.10

0.15

0.20

0.25

16°

24°

32°

40°

8° 16°24°

32°

40°

69

67

71

71

69

70

74

72

72

77

75

74

71

74

74

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—16—16

—10—9

—5—6

—3—4

—11—9

—20—15

—30—22

—40—29

8—14—15

—9—7

—5—6

—3—4

—11—9

—19—14

—29—20

—38—27

16—11—11

—6—5

—4—5

—7—7

—12—11

—16—14

—24—19

—30—24

16—10

—9—4—4

—4—5

—7—7

—11—11

—15—14

—23—19

—29—23

24 — 40 24 — 40—6—6

—6—5

—6—7

—9—9

—12—13

—16—16

—19—22

—24—26

—5—4

—4—3

—6—7

—9—9

—12—13

—15—15

—18—20

—22—25

JM AEROFOIL

Page 79: JM Aerofoil 50 Hz Technical

BS 5750 Pt 1

EN 29001

ISO 9001

04/03/99SK11706

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.50

50

100

150

200

250

3000 2000 4000 6000 8000 10000 12000

0 1000 2000 3000 4000 5000 6000 7000

0

5

10

15

20

25

30

0.0

0.2

0.4

0.6

0.8

1.0

1.2

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.50.00.10.20.30.40.50.60.70.8

16°

24°

32°

40°

8°16°

24°

32°

40°

80

79

80

83

82

82

85

84

84

88

88

87

79

80

82

ISO 5801

TypeD

V

63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k

8Ð13

Ð15

Ð9

Ð7

Ð8

Ð10

Ð3

Ð6

Ð8

Ð6

Ð14

Ð10

Ð22

Ð15

Ð29

Ð218

Ð12

Ð15

Ð7

Ð6

Ð8

Ð9

Ð3

Ð6

Ð8

Ð6

Ð14

Ð8

Ð21

Ð14

Ð27

Ð19

16Ð12

Ð11

Ð7

Ð3

Ð10

Ð9

Ð4

Ð9

Ð8

Ð11

Ð12

Ð12

Ð18

Ð16

Ð25

Ð1916

Ð11

Ð11

Ð7

Ð3

Ð10

Ð9

Ð4

Ð9

Ð8

Ð11

Ð12

Ð12

Ð18

Ð15

Ð23

Ð18

24 Ð 40 24 Ð 40Ð5

Ð6

Ð5

Ð4

Ð9

Ð9

Ð10

Ð10

Ð13

Ð13

Ð14

Ð15

Ð18

Ð19

Ð21

Ð24

Ð4

Ð6

Ð4

Ð3

Ð9

Ð9

Ð10

Ð10

Ð13

Ð13

Ð14

Ð15

Ð17

Ð18

Ð20

Ð22

Fan Code: 50JM/16/4/5/...500 mm 1420 rev/min 5 Blades 50 Hz

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformanceshownis for installationstypeDÐDucted inlet,Ductedoutlet.Performanceratingsdonot includetheeffectsofappurtenances.

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory

specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use

upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet LevelsOctave Band Centre Frequency (Hz) Octave Band Centre Frequency (Hz)Pitch

AnglePitchAngle

Air Density 1.2 kg/m3

JM AEROFOIL

Page 80: JM Aerofoil 50 Hz Technical

BS 5750 Pt 1

EN 29001

ISO 9001

04/03/99SK11707

0.0 0.5 1.0 1.5 2.0 2.5 3.00

50

100

150

2000 2000 4000 6000 8000 10000

0 1000 2000 3000 4000 5000 6000

0

5

10

15

20

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.0 0.5 1.0 1.5 2.0 2.5 3.00.0

0.1

0.2

0.3

0.4

0.5

78

76

78

78

16°

24°

32°

8°16°

24°

32°

76

78

83

82

82

76

76

85

ISO 5801

Type D

V

63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k

8Ð16

Ð8

Ð15

Ð10

Ð7

Ð6

Ð3

Ð6

Ð6

Ð7

Ð16

Ð12

Ð24

Ð15

Ð34

Ð208

Ð13

Ð6

Ð14

Ð10

Ð7

Ð6

Ð3

Ð6

Ð6

Ð7

Ð15

Ð12

Ð23

Ð13

Ð32

Ð18

16Ð8

Ð5

Ð7

Ð8

Ð5

Ð6

Ð7

Ð8

Ð11

Ð11

Ð16

Ð15

Ð19

Ð18

Ð25

Ð2416

Ð6

Ð3

Ð7

Ð8

Ð5

Ð6

Ð7

Ð8

Ð11

Ð11

Ð15

Ð15

Ð18

Ð17

Ð24

Ð23

24 Ð 36 24 Ð 36Ð5

Ð4

Ð8

Ð9

Ð6

Ð6

Ð10

Ð9

Ð11

Ð12

Ð15

Ð16

Ð18

Ð20

Ð23

Ð26

Ð3

Ð1

Ð7

Ð8

Ð6

Ð6

Ð9

Ð9

Ð10

Ð12

Ð14

Ð16

Ð17

Ð19

Ð20

Ð24

Fan Code: 50JM/20/4/3/...500 mm 1420 rev/min 3 Blades 50 Hz

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformanceshownis for installationstypeDÐDucted inlet,Ductedoutlet.Performanceratingsdonot includetheeffectsofappurtenances.

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory

specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use

upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet LevelsOctave Band Centre Frequency (Hz) Octave Band Centre Frequency (Hz)Pitch

AnglePitchAngle

Air Density 1.2 kg/m3

JM AEROFOIL

Page 81: JM Aerofoil 50 Hz Technical

Fan Code: 50JM/20/4/6/...500 mm 1420 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11708

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.50

50

100

150

200

250

3000 2000 4000 6000 8000 10000 12000

0 1000 2000 3000 4000 5000 6000 7000

0

5

10

15

20

25

30

0.0

0.2

0.4

0.6

0.8

1.0

1.2

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.50.00.10.20.30.40.50.60.70.80.9

16°

24°

32°

40°

8° 16°24°

32°

40°

79

77

81

81

79

80

84

83

83

88

86

85

80

83

84

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—20—19

—12—12

—8—7

—3—5

—6—5

—14—12

—23—16

—34—24

8—17—18

—10—10

—8—7

—3—5

—5—5

—13—11

—22—15

—32—23

16—15—14

—6—6

—5—6

—7—7

—9—8

—13—13

—18—15

—26—21

16—14—13

—5—4

—5—6

—7—7

—8—8

—13—13

—18—15

—25—20

24 — 40 24 — 36—7—7

—5—5

—7—8

—9—9

—11—11

—14—15

—18—18

—22—24

—5—5

—4—3

—7—7

—9—9

—10—11

—13—15

—16—17

—21—23

JM AEROFOIL

Page 82: JM Aerofoil 50 Hz Technical

Fan Code: 50JM/20/2/3/...500 mm 2910 rev/min 3 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11710

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 5 60

100

200

300

400

500

600

700

8000 5000 10000 15000 20000

0 2000 4000 6000 8000 10000 12000

0

10

20

30

40

50

60

70

80

0.0

0.5

1.0

1.5

2.0

2.5

3.0

0 1 2 3 4 5 60.00.51.01.52.02.53.03.54.0

16°

24°

32°

8°16°

24°

32°

94

92

94

94

92

94

100

98

98

92

92

100

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—21—15

—16—8

—15—11

—8—7

—4—7

—7—8

—17—13

—25—15

8—18—14

—14—5

—14—10

—7—6

—3—7

—6—7

—16—11

—22—12

16—11—12

—9—6

—7—9

—5—6

—8—9

—12—11

—17—16

—20—19

16—10—10

—7—3

—6—8

—5—6

—8—9

—11—11

—16—15

—19—17

24 — 36 24 — 36—9—9

—5—4

—8—10

—7—7

—11—10

—12—12

—16—17

—19—21

—7—7

—4—2

—8—9

—7—7

—10—10

—10—12

—14—16

—16—19

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

JM AEROFOIL

Page 83: JM Aerofoil 50 Hz Technical

Fan Code: 50JM/20/2/6/...500 mm 2910 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11711

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 5 6 70

200

400

600

800

1000

12000 5000 10000 15000 20000

0 2000 4000 6000 8000 10000 12000 14000

0

20

40

60

80

100

120

0

1

2

3

4

0 1 2 3 4 5 6 7012345678

16°

24°

32°

40°

8° 16°24°

32°

40°

95

93

97

97

95

96

101

99

99

104

102

101

96

99

100

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—19—17

—20—20

—13—12

—9—8

—4—6

—7—5

—16—12

—24—17

8—16—15

—19—19

—11—10

—8—7

—3—5

—5—4

—14—11

—21—15

16—11—11

—16—15

—7—7

—5—6

—7—8

—9—9

—14—13

—19—16

16—10

—9—16—15

—5—4

—5—5

—7—8

—9—8

—14—13

—18—15

24 — 40 24 — 40—8—8

—8—8

—7—6

—8—9

—10—10

—12—12

—16—16

—19—19

—6—5

—7—8

—5—4

—7—8

—9—10

—11—11

—14—15

—17—18

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

JM AEROFOIL

Page 84: JM Aerofoil 50 Hz Technical

Fan Code: 56JM/16/8/5/...560 mm 670 rev/min 5 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11713

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.5 1.0 1.5 2.0 2.50

10

20

30

40

50

60

700 2000 4000 6000 8000

0 1000 2000 3000 4000 5000

0

1

2

3

4

5

6

7

0.00

0.05

0.10

0.15

0.20

0.25

0.0 0.5 1.0 1.5 2.0 2.50.000.020.040.060.080.100.120.14

16°

24°

32°

40°

8°16°

24°

32°

40°

68

65

71

70

68

67

72

70

68

74

74

72

66

67

75

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—12

—7—10—11

—3—7

—7—5

—12—8

—20—13

—29—20

—37—24

8—10

—6—10—11

—3—7

—7—5

—12—8

—20—12

—28—19

—35—23

16—11—3

—12—8

—3—7

—7—10

—12—13

—19—16

—28—20

—34—23

16—10

—3—12

—8—3—7

—7—10

—12—13

—19—15

—27—19

—33—21

24 — 40 24 — 40—3—3

—9—8

—7—8

—10—11

—12—14

—15—18

—20—23

—23—28

—2—2

—8—8

—7—8

—10—11

—12—14

—15—18

—19—22

—22—26

JM AEROFOIL

Page 85: JM Aerofoil 50 Hz Technical

Fan Code: 56JM/16/6/5/...560 mm 900 rev/min 5 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11714

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.5 1.0 1.5 2.0 2.5 3.00

20

40

60

80

100

1200 2000 4000 6000 8000 10000

0 1000 2000 3000 4000 5000 6000

0

2

4

6

8

10

12

0.0

0.1

0.2

0.3

0.4

0.0 0.5 1.0 1.5 2.0 2.5 3.00.000.050.100.150.200.250.300.35

16°

24°

32°

40°

8°16°

24°

32°

40°

74

71

77

76

74

73

78

76

74

81

80

79

71

72

80

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—12

—8—11—11

—3—8

—5—5

—10—7

—18—12

—26—17

—33—22

8—10

—7—11—11

—3—8

—5—5

—10—7

—18—11

—25—17

—31—21

16—12

—4—13

—8—3—7

—6—10

—10—12

—17—15

—25—18

—32—21

16—11—3

—13—8

—3—7

—5—10

—10—12

—17—14

—24—18

—30—20

24 — 40 24 — 40—4—3

—9—8

—7—8

—10—10

—12—14

—15—17

—18—21

—21—26

—3—2

—9—8

—7—8

—10—10

—12—14

—15—17

—17—20

—20—24

JM AEROFOIL

Page 86: JM Aerofoil 50 Hz Technical

Fan Code: 56JM/20/6/3/...560 mm 900 rev/min 3 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11715

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.5 1.0 1.5 2.0 2.5 3.00

10

20

30

40

50

60

70

80

900 2000 4000 6000 8000 10000

0 1000 2000 3000 4000 5000 6000

0

2

4

6

8

0.00

0.05

0.10

0.15

0.20

0.25

0.30

0.35

0.0 0.5 1.0 1.5 2.0 2.5 3.00.00

0.05

0.10

0.15

0.20

16°

24°

32°

8°16°

24°

32°

72

70

72

69

68

69

77

75

74

69

68

76

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—16

—6—11—7

—5—7

—3—7

—11—11

—20—14

—29—17

—40—21

8—14

—3—10

—7—5—7

—3—7

—11—11

—19—13

—28—16

—38—19

16—6—4

—5—6

—5—7

—10—10

—15—15

—18—18

—22—22

—28—27

16—4—2

—5—6

—5—7

—10—10

—15—15

—17—18

—22—21

—27—25

24 — 36 24 — 36—5—4

—6—6

—8—8

—9—10

—13—15

—16—18

—20—23

—25—28

—3—1

—5—6

—8—8

—8—10

—12—15

—15—18

—18—22

—23—26

JM AEROFOIL

Page 87: JM Aerofoil 50 Hz Technical

Fan Code: 56JM/20/6/6/...560 mm 900 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11716

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.50

20

40

60

80

100

120

1400 2000 4000 6000 8000 10000 12000

0 1000 2000 3000 4000 5000 6000 7000

0

2

4

6

8

10

12

14

0.0

0.1

0.2

0.3

0.4

0.5

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.50.000.050.100.150.200.250.300.350.40

16°

24°

32°

40°

8° 16°24°

32°

40°

72

70

73

74

72

73

78

77

76

81

80

78

72

75

78

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—22—18

—11—8

—8—7

—2—3

—9—8

—19—14

—29—20

—39—27

8—20—17

—9—6

—8—7

—2—3

—9—8

—18—13

—28—19

—37—25

16—14—11

—5—4

—5—6

—6—7

—12—12

—17—15

—24—19

—30—24

16—13

—9—3—2

—5—6

—6—7

—12—12

—16—15

—24—19

—29—23

24 — 40 24 — 40—6—5

—6—6

—7—8

—10—10

—12—13

—15—17

—18—21

—22—25

—5—3

—4—3

—7—8

—9—10

—12—13

—14—16

—17—20

—20—25

JM AEROFOIL

Page 88: JM Aerofoil 50 Hz Technical

Fan Code: 56JM/16/4/5/...560 mm 1420 rev/min 5 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11717

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 50

50

100

150

200

250

3000 5000 10000 15000

0 2000 4000 6000 8000 10000

0

5

10

15

20

25

30

0.0

0.2

0.4

0.6

0.8

1.0

1.2

0 1 2 3 4 50.00.20.40.60.81.01.21.4

16°

24°

32°

40°

8°16°

24°

32°

40°

84

81

86

86

84

83

88

87

85

92

91

89

81

82

89

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—17—17

—12—8

—10—11

—3—6

—7—5

—12—8

—20—13

—28—19

8—16—17

—10—6

—10—11

—3—6

—7—5

—12—7

—20—13

—26—18

16—17—12

—11—4

—12—8

—2—7

—7—11

—12—13

—19—16

—27—20

16—16—12

—11—3

—12—8

—2—7

—7—11

—12—13

—19—15

—25—18

24 — 40 24 — 40—7—7

—4—4

—9—9

—8—9

—11—12

—13—15

—16—19

—20—24

—6—6

—4—3

—9—9

—8—9

—11—12

—13—15

—16—18

—19—22

JM AEROFOIL

Page 89: JM Aerofoil 50 Hz Technical

Fan Code: 56JM/20/4/3/...560 mm 1420 rev/min 3 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11718

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.50

50

100

150

200

2500 2000 4000 6000 8000 10000 12000 14000

0 2000 4000 6000 8000

0

5

10

15

20

25

0.0

0.2

0.4

0.6

0.8

1.0

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.50.00.10.20.30.40.50.60.70.8

16°

24°

32°

8°16°

24°

32°

82

80

83

80

78

79

88

86

85

79

78

86

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—16

—6—14—10

—9—7

—3—8

—5—8

—15—13

—23—15

—33—19

8—14

—3—14—10

—9—7

—3—7

—5—8

—14—12

—22—13

—31—16

16—7—4

—7—8

—5—6

—8—9

—11—12

—17—17

—19—19

—25—24

16—5—2

—7—8

—5—6

—8—9

—11—12

—16—17

—18—18

—24—23

24 — 36 24 — 36—5—4

—8—9

—7—7

—9—9

—10—12

—15—17

—18—20

—23—26

—3—1

—8—8

—7—7

—9—9

—9—12

—14—17

—16—19

—20—24

JM AEROFOIL

Page 90: JM Aerofoil 50 Hz Technical

Fan Code: 56JM/20/4/6/...560 mm 1420 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11719

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 50

50

100

150

200

250

300

3500 5000 10000 15000

0 2000 4000 6000 8000 10000

0

5

10

15

20

25

30

35

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

0 1 2 3 4 50.00.20.40.60.81.01.21.41.6

16°

24°

32°

40°

8° 16°24°

32°

40°

82

80

83

85

83

84

90

88

88

93

91

90

82

85

88

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—24—21

—12—10

—12—9

—4—6

—4—4

—12—11

—22—16

—32—22

8—21—19

—10—8

—12—8

—3—6

—4—4

—11—10

—21—14

—31—21

16—17—14

—6—4

—7—7

—5—8

—9—9

—14—14

—19—16

—26—21

16—16—12

—4—3

—7—6

—5—8

—8—9

—13—14

—19—16

—26—20

24 — 40 24 — 40—7—6

—5—5

—9—9

—9—10

—12—12

—14—16

—17—19

—21—24

—5—4

—4—3

—9—9

—9—10

—11—12

—13—15

—16—18

—19—23

JM AEROFOIL

Page 91: JM Aerofoil 50 Hz Technical

Fan Code: 56JM/20/2/3/...560 mm 2910 rev/min 3 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11720

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 5 6 7 8 90

200

400

600

800

10000 5000 10000 15000 20000 25000 30000

0 5000 10000 15000

0

20

40

60

80

100

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

0 1 2 3 4 5 6 7 8 901234567

16°

24°

32°

8°16°

24°

32°

98

96

98

96

94

95

104

102

101

95

94

102

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—23—15

—16—6

—14—10

—10—7

—4—8

—5—8

—16—13

—23—15

8—20—13

—14—3

—13—9

—9—7

—3—8

—4—7

—14—12

—21—12

16—14—11

—7—4

—7—9

—5—7

—9—9

—12—12

—18—18

—20—20

16—12—10

—5—2

—7—8

—5—7

—8—9

—11—12

—17—17

—19—18

24 — 36 24 — 36—10

—9—6—4

—9—9

—7—7

—10—10

—11—13

—16—18

—19—21

—8—6

—4—1

—8—9

—7—7

—9—10

—9—12

—14—17

—16—19

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

JM AEROFOIL

Page 92: JM Aerofoil 50 Hz Technical

Fan Code: 56JM/20/2/6/...560 mm 2910 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11721

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2 4 6 8 100

200

400

600

800

1000

1200

1400

16000 5000 10000 15000 20000 25000 30000

0 5000 10000 15000 20000

0

20

40

60

80

100

120

140

160

0

1

2

3

4

5

6

0 2 4 6 8 1002468

101214

16°

24°

32°

40°

8° 16°24°

32°

40°

98

96

99

101

99

100

106

104

104

109

108

106

98

100

104

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—21—16

—24—21

—13—11

—12—9

—3—6

—5—4

—13—11

—22—16

8—19—14

—23—21

—11—8

—12—8

—3—6

—4—3

—12—10

—20—14

16—12

—9—18—15

—6—5

—7—7

—6—9

—9—9

—15—15

—19—16

16—11—8

—18—14

—4—3

—6—6

—5—8

—9—9

—14—14

—18—16

24 — 40 24 — 40—7—7

—8—7

—6—6

—10—10

—10—11

—13—14

—15—17

—18—20

—6—4

—8—7

—4—4

—9—9

—10—11

—12—13

—14—16

—16—19

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

JM AEROFOIL

Page 93: JM Aerofoil 50 Hz Technical

Fan Code: 63JM/20/8/3/...630 mm 680 rev/min 3 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11722

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.5 1.0 1.5 2.0 2.5 3.00

10

20

30

40

50

60

700 2000 4000 6000 8000 10000

0 1000 2000 3000 4000 5000 6000

0

1

2

3

4

5

6

7

0.00

0.05

0.10

0.15

0.20

0.25

0.0 0.5 1.0 1.5 2.0 2.5 3.00.000.020.040.060.080.100.120.140.160.18

16°

24°

32°

8°16°

24°

32°

70

68

72

71

70

69

74

72

71

69

73

73

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—11—7

—5—5

—4—7

—8—9

—14—10

—21—14

—27—21

—36—30

8—9—5

—5—5

—4—7

—8—8

—14—10

—20—13

—26—20

—34—28

16—10

—3—4—5

—5—11

—10—13

—14—13

—21—17

—28—23

—35—30

16—8—2

—4—5

—5—11

—10—13

—14—13

—21—17

—26—22

—33—28

24 — 36 24 — 36—4—3

—5—5

—10—11

—12—14

—14—16

—17—20

—21—24

—26—28

—2—2

—5—5

—10—11

—12—14

—14—16

—17—20

—20—22

—24—26

JM AEROFOIL

Page 94: JM Aerofoil 50 Hz Technical

Fan Code: 63JM/20/8/6/...630 mm 680 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11723

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.50

20

40

60

80

1000 2000 4000 6000 8000 10000 12000

0 1000 2000 3000 4000 5000 6000 7000

0

2

4

6

8

10

0.00

0.05

0.10

0.15

0.20

0.25

0.30

0.35

0.40

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.50.00

0.05

0.10

0.15

0.20

0.25

0.30

16°

24°

32°

8° 16°24°

32°

70

70

71

73

69

70

75

74

73

73

73

73

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—8

—11—7—8

—4—5

—8—5

—13—10

—19—16

—26—24

—36—33

8—6

—10—7—8

—4—5

—8—5

—13—10

—19—15

—25—23

—34—32

16—8—5

—6—6

—5—7

—8—10

—10—11

—18—15

—25—21

—34—28

16—7—5

—6—6

—5—7

—8—10

—10—11

—18—15

—24—20

—32—27

24 — 36 24 — 36—4—3

—6—6

—8—10

—12—13

—14—16

—18—20

—22—25

—28—30

—3—2

—5—6

—8—10

—12—13

—14—16

—18—20

—22—24

—26—28

JM AEROFOIL

Page 95: JM Aerofoil 50 Hz Technical

Fan Code: 63JM/20/6/3/...630 mm 900 rev/min 3 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11724

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.00

20

40

60

80

100

120

1400 2000 4000 6000 8000 10000 12000

0 1000 2000 3000 4000 5000 6000 7000 8000

0

2

4

6

8

10

12

14

0.0

0.1

0.2

0.3

0.4

0.5

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.00.000.050.100.150.200.250.300.350.40

16°

24°

32°

8°16°

24°

32°

79

77

79

79

78

78

82

80

80

76

79

79

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—9—4

—7—8

—4—8

—7—9

—13—12

—20—15

—26—20

—33—29

8—6—2

—7—8

—4—8

—7—9

—13—12

—19—14

—25—20

—30—27

16—7—1

—6—8

—4—12

—10—16

—14—16

—20—20

—27—24

—33—30

16—5—1

—6—8

—4—12

—10—16

—14—16

—20—19

—25—23

—30—28

24 — 36 24 — 36—2—1

—7—8

—11—13

—14—16

—15—19

—19—22

—22—25

—26—29

—10

—7—8

—11—13

—14—16

—15—19

—19—22

—21—24

—24—27

JM AEROFOIL

Page 96: JM Aerofoil 50 Hz Technical

Fan Code: 63JM/20/6/6/...630 mm 900 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11725

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.50

20

40

60

80

100

120

140

160

1800 2000 4000 6000 8000 10000 12000 14000

0 2000 4000 6000 8000

0

5

10

15

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.50.00.10.20.30.40.50.60.7

16°

24°

32°

8° 16°24°

32°

78

77

79

80

78

77

82

80

79

80

81

81

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—9

—12—8—9

—4—6

—6—4

—12—9

—18—15

—24—21

—32—30

8—8

—12—7—8

—4—6

—7—4

—12—9

—18—14

—23—21

—30—28

16—11—8

—7—4

—5—7

—7—9

—10—11

—16—14

—23—19

—30—26

16—10

—7—7—4

—5—7

—7—9

—10—11

—16—14

—22—18

—28—24

24 — 36 24 — 36—6—4

—4—4

—6—9

—11—12

—14—16

—18—19

—21—24

—25—28

—5—4

—4—4

—6—9

—11—12

—14—16

—18—19

—21—23

—24—26

JM AEROFOIL

Page 97: JM Aerofoil 50 Hz Technical

Fan Code: 63JM/25/6/9/...630 mm 935 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11728

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.50

50

100

150

200

2500 2000 4000 6000 8000 10000 12000 14000

0 2000 4000 6000 8000

0

5

10

15

20

25

0.0

0.2

0.4

0.6

0.8

1.0

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.50.00.10.20.30.40.50.60.70.80.9

16°

24°

32°

40°

8° 16°24°

32°

40°

74

72

80

76

75

76

80

80

78

84

83

81

74

74

81

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—10—10

—9—8

—6—8

—5—6

—8—8

—15—8

—24—15

—31—17

8—8—9

—7—6

—6—8

—5—7

—8—8

—14—8

—24—14

—30—15

16—11—8

—7—4

—5—8

—6—11

—9—11

—15—11

—21—17

—26—17

16—9—7

—6—2

—5—8

—6—11

—9—11

—15—11

—21—16

—25—16

24 — 40 24 — 40—7—5

—4—5

—6—7

—12—13

—13—14

—16—17

—20—23

—23—26

—5—3

—3—3

—6—7

—12—13

—13—14

—15—17

—19—22

—22—25

JM AEROFOIL

Page 98: JM Aerofoil 50 Hz Technical

Fan Code: 63JM/20/4/3/...630 mm 1420 rev/min 3 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11729

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 5 60

50

100

150

200

250

3000 5000 10000 15000 20000

0 2000 4000 6000 8000 10000 12000

0

5

10

15

20

25

30

0.0

0.2

0.4

0.6

0.8

1.0

1.2

0 1 2 3 4 5 60.00.20.40.60.81.01.21.41.6

16°

24°

32°

8°16°

24°

32°

91

90

90

91

91

90

94

93

92

88

90

90

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—7—2

—13—12

—6—9

—5—10

—10—13

—15—14

—22—19

—29—25

8—5—1

—12—11

—6—9

—5—10

—10—13

—14—13

—21—18

—26—23

16—5—1

—12—10

—5—11

—7—17

—13—20

—16—19

—24—23

—30—29

16—4

0—12—10

—5—11

—7—17

—12—19

—15—19

—22—22

—27—27

24 — 36 24 — 36—2—1

—9—9

—9—11

—15—17

—16—19

—19—22

—22—26

—26—29

—10

—9—9

—9—11

—15—17

—16—19

—18—21

—20—24

—24—27

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

JM AEROFOIL

Page 99: JM Aerofoil 50 Hz Technical

Fan Code: 63JM/20/4/6/...630 mm 1420 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11730

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 5 6 70

50

100

150

200

250

300

350

400

4500 5000 10000 15000 20000

0 2000 4000 6000 8000 10000 12000 14000

0

10

20

30

40

0.0

0.5

1.0

1.5

0 1 2 3 4 5 6 70.0

0.5

1.0

1.5

2.0

2.5

16°

24°

32°

8° 16°24°

32°

88

87

89

91

88

88

92

91

90

90

91

91

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—12—15

—8—10

—7—8

—4—5

—9—6

—13—10

—21—17

—27—24

8—11—15

—7—10

—7—8

—4—5

—9—6

—13—9

—20—17

—25—23

16—14—11

—8—5

—6—6

—5—8

—9—11

—11—12

—19—16

—25—22

16—13—11

—8—5

—6—6

—5—8

—9—11

—11—11

—18—15

—24—20

24 — 36 24 — 36—8—6

—4—4

—6—7

—9—11

—13—14

—15—17

—19—21

—23—26

—7—6

—4—3

—6—7

—9—11

—13—14

—15—17

—18—20

—22—24

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

JM AEROFOIL

Page 100: JM Aerofoil 50 Hz Technical

Fan Code: 63JM/25/4/6/...630 mm 1440 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11732

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 5 6 70

50

100

150

200

250

300

350

4000 5000 10000 15000 20000

0 2000 4000 6000 8000 10000 12000 14000

0

5

10

15

20

25

30

35

40

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

0 1 2 3 4 5 6 70.0

0.5

1.0

1.5

2.0

2.5

16°

24°

32°

8°16°

24°

32°

85

83

86

89

87

89

91

91

90

81

82

90

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—11—6

—11—7

—8—8

—4—9

—6—10

—12—10

—19—12

—28—16

8—9—5

—9—6

—7—7

—4—9

—6—11

—12—10

—19—11

—26—14

16—7—5

—7—6

—5—7

—9—11

—11—13

—11—14

—17—16

—21—21

16—6—3

—6—5

—5—6

—9—11

—10—13

—11—14

—16—16

—21—20

24 — 36 24 — 32—4—4

—7—6

—6—8

—9—12

—13—15

—15—17

—20—22

—25—27

—3—1

—6—4

—6—7

—9—12

—13—15

—14—17

—19—21

—23—26

JM AEROFOIL

Page 101: JM Aerofoil 50 Hz Technical

Fan Code: 63JM/25/4/9/...630 mm 1440 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11733

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 5 6 70

100

200

300

400

5000 5000 10000 15000 20000

0 2000 4000 6000 8000 10000 12000 14000

0

10

20

30

40

50

0.0

0.5

1.0

1.5

2.0

0 1 2 3 4 5 6 70.00.51.01.52.02.53.03.5

16°

24°

32°

40°

8° 16°24°

32°

40°

83

82

89

87

86

86

92

90

89

96

94

93

83

84

90

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—13—13

—10—10

—9—8

—6—7

—5—7

—10—8

—18—10

—27—16

8—11—12

—9—10

—7—6

—6—7

—4—7

—10—7

—17—9

—25—14

16—12

—9—11—9

—7—5

—4—8

—8—11

—11—11

—17—12

—23—17

16—11—7

—10—8

—5—3

—4—8

—8—11

—10—11

—17—12

—22—16

24 — 40 24 — 40—6—4

—8—7

—5—6

—9—10

—13—15

—14—16

—19—21

—22—26

—4—2

—7—6

—4—4

—9—10

—13—15

—14—16

—17—20

—21—25

JM AEROFOIL

Page 102: JM Aerofoil 50 Hz Technical

Fan Code: 63JM/25/2/3/...630 mm 2910 rev/min 3 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11734

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2 4 6 8 10 120

200

400

600

800

1000

12000 5000 10000 15000 20000 25000 30000 35000 40000

0 5000 10000 15000 20000 25000

0

20

40

60

80

100

120

0

1

2

3

4

0 2 4 6 8 10 120

2

4

6

8

10

16°

24°

32°

8°16°

24°

32°

100

99

100

105

103

104

109

107

107

95

95

103

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—23—16

—12—4

—13—7

—8—8

—4—11

—8—14

—14—15

—21—15

8—20—15

—9—1

—11—5

—8—7

—3—11

—7—13

—13—13

—18—12

16—16—12

—6—4

—6—6

—6—8

—7—12

—12—16

—17—18

—20—20

16—15—11

—5—1

—6—5

—6—8

—7—12

—12—16

—16—17

—19—19

24 — 32 24 — 32—6—7

—5—4

—7—6

—9—10

—14—15

—17—18

—20—21

—23—24

—4—5

—3—2

—6—5

—9—10

—13—15

—16—17

—18—19

—20—22

JM AEROFOIL

Page 103: JM Aerofoil 50 Hz Technical

Fan Code: 63JM/25/2/6/...630 mm 2910 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11735

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2 4 6 8 10 12 140

200

400

600

800

1000

1200

1400

16000 10000 20000 30000 40000

0 5000 10000 15000 20000 25000

0

20

40

60

80

100

120

140

160

0

1

2

3

4

5

6

0 2 4 6 8 10 12 1402468

1012141618

16°

24°

32°

8°16°

24°

32°

100

98

102

105

103

106

108

107

107

97

97

105

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—20—16

—11—6

—11—7

—8—8

—5—9

—7—11

—13—11

—20—12

8—17—15

—11—6

—10—6

—6—7

—4—9

—6—10

—12—9

—18—10

16—10—11

—7—5

—8—6

—5—7

—10—12

—11—13

—12—14

—17—17

16—9

—10—7—5

—7—5

—5—6

—9—12

—11—13

—12—14

—16—16

24 — 36 24 — 36—6—7

—6—5

—8—7

—8—9

—11—13

—14—16

—17—18

—21—23

—4—4

—5—4

—8—6

—7—8

—11—13

—13—16

—15—17

—20—22

JM AEROFOIL

Page 104: JM Aerofoil 50 Hz Technical

Fan Code: 63JM/25/2/9/...630 mm 2910 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11736

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2 4 6 8 10 12 140

500

1000

1500

20000 10000 20000 30000 40000

0 5000 10000 15000 20000 25000

0

50

100

150

200

0

1

2

3

4

5

6

7

8

0 2 4 6 8 10 12 140

5

10

15

20

25

30

16°

24°

32°

40°

8° 16°24°

32°

40°

99

98

105

103

102

102

109

107

105

113

111

109

99

99

106

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—16—15

—14—13

—10—11

—9—8

—6—7

—5—7

—11—8

—18—11

8—14—13

—13—13

—10—10

—7—6

—6—7

—4—6

—10—7

—16—9

16—14

—9—13

—9—11—9

—7—5

—4—9

—8—11

—12—12

—17—13

16—12

—8—13

—9—11—9

—5—3

—4—9

—8—11

—11—12

—17—12

24 — 40 24 — 40—7—6

—7—6

—9—9

—6—8

—10—12

—14—16

—16—18

—20—22

—6—4

—6—5

—8—8

—4—6

—10—12

—13—16

—14—17

—18—21

JM AEROFOIL

Page 105: JM Aerofoil 50 Hz Technical

Fan Code: 71JM/20/8/3/...710 mm 680 rev/min 3 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11737

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.00

10

20

30

40

50

60

70

80

900 2000 4000 6000 8000 10000 12000

0 1000 2000 3000 4000 5000 6000 7000 8000

0

2

4

6

8

0.00

0.05

0.10

0.15

0.20

0.25

0.30

0.35

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.00.00

0.05

0.10

0.15

0.20

0.25

0.30

16°

24°

32°

8°16°

24°

32°

73

71

74

74

73

72

78

76

74

72

74

76

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—13

—8—7—7

—3—6

—8—7

—12—9

—19—14

—25—20

—35—29

8—11—7

—6—6

—3—6

—8—7

—12—9

—19—13

—24—19

—32—27

16—9—4

—5—5

—5—9

—9—12

—11—12

—17—15

—22—20

—29—26

16—8—3

—5—5

—5—9

—9—12

—11—12

—17—15

—20—18

—27—24

24 — 36 24 — 36—5—3

—6—5

—9—10

—10—12

—10—13

—14—17

—18—20

—25—27

—3—2

—6—5

—9—10

—10—12

—10—13

—14—16

—17—19

—23—24

JM AEROFOIL

Page 106: JM Aerofoil 50 Hz Technical

Fan Code: 71JM/20/8/6/...710 mm 680 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11738

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 50

20

40

60

80

100

120

1400 5000 10000 15000

0 2000 4000 6000 8000 10000

0

2

4

6

8

10

12

14

0.0

0.1

0.2

0.3

0.4

0.5

0 1 2 3 4 50.000.050.100.150.200.250.300.350.400.45

16°

24°

32°

8°16°

24°

32°

76

74

76

77

75

74

80

78

76

77

78

78

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—11—12

—7—9

—4—5

—7—5

—11—8

—18—16

—25—22

—34—32

8—9

—12—7—9

—4—5

—7—5

—11—8

—18—14

—24—22

—32—31

16—11—6

—6—6

—4—7

—8—9

—11—10

—18—14

—24—19

—34—27

16—10

—6—6—6

—4—7

—8—9

—11—10

—18—14

—24—19

—32—25

24 — 36 24 — 36—5—4

—6—5

—7—8

—10—12

—11—13

—15—17

—19—21

—26—28

—4—3

—6—5

—7—8

—10—12

—11—13

—15—17

—18—20

—24—26

JM AEROFOIL

Page 107: JM Aerofoil 50 Hz Technical

Fan Code: 71JM/25/8/6/...710 mm 695 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11740

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.50

20

40

60

80

100

1200 2000 4000 6000 8000 10000 12000 14000

0 2000 4000 6000 8000

0

2

4

6

8

10

12

0.0

0.1

0.2

0.3

0.4

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.50.000.050.100.150.200.250.300.350.400.45

16°

24°

32°

8°16°

24°

32°

71

70

74

74

73

75

77

76

75

70

71

79

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—13

—9—9—8

—4—7

—5—6

—12—8

—18—10

—26—18

—34—26

8—11—7

—8—8

—4—7

—5—6

—12—8

—17—10

—25—17

—33—24

16—9—6

—6—5

—7—8

—6—10

—10—12

—14—14

—21—20

—27—26

16—7—4

—5—4

—7—8

—6—10

—9—12

—14—14

—21—20

—27—25

24 — 36 24 — 36—6—5

—6—6

—7—7

—8—10

—12—13

—16—16

—19—21

—23—25

—4—2

—5—5

—7—7

—8—10

—11—13

—15—16

—17—20

—21—24

JM AEROFOIL

Page 108: JM Aerofoil 50 Hz Technical

Fan Code: 71JM/25/8/9/...710 mm 695 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11741

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.50

20

40

60

80

100

120

1400 2000 4000 6000 8000 10000 12000 14000

0 2000 4000 6000 8000

0

2

4

6

8

10

12

14

0.0

0.1

0.2

0.3

0.4

0.5

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.50.0

0.1

0.2

0.3

0.4

0.5

0.6

16°

24°

32°

8° 16°24°

32°

72

71

76

74

73

73

77

75

74

74

74

78

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—10—10

—9—8

—6—7

—4—6

—10—8

—17—10

—26—20

—34—27

8—8—9

—7—6

—6—7

—4—6

—10—8

—16—9

—25—19

—33—26

16—10

—9—7—5

—4—6

—7—8

—11—10

—16—12

—23—20

—30—27

16—9—7

—6—3

—4—6

—7—8

—11—10

—16—12

—23—20

—29—26

24 — 36 24 — 36—8—7

—5—5

—6—6

—8—9

—11—12

—14—15

—18—21

—22—25

—6—5

—4—3

—6—6

—8—9

—11—12

—13—15

—17—20

—20—24

JM AEROFOIL

Page 109: JM Aerofoil 50 Hz Technical

Fan Code: 71JM/20/6/3/...710 mm 900 rev/min 3 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11742

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 5 60

20

40

60

80

100

120

140

1600 5000 10000 15000 20000

0 2000 4000 6000 8000 10000 12000

0

2

4

6

8

10

12

14

16

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0 1 2 3 4 5 60.00.10.20.30.40.50.60.7

16°

24°

32°

8°16°

24°

32°

80

78

80

81

81

80

86

83

82

78

80

82

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—12

—6—9—8

—3—7

—6—7

—11—9

—18—14

—23—19

—31—27

8—10

—4—8—8

—3—7

—6—7

—11—9

—17—12

—22—18

—28—25

16—7—2

—7—7

—5—10

—8—14

—11—13

—16—17

—20—20

—27—26

16—5—2

—7—7

—5—10

—8—14

—11—13

—16—16

—19—19

—24—24

24 — 36 24 — 36—4—2

—7—7

—9—11

—11—13

—10—14

—14—18

—17—21

—23—26

—2—1

—7—7

—9—11

—11—13

—10—14

—14—17

—16—19

—21—24

JM AEROFOIL

Page 110: JM Aerofoil 50 Hz Technical

Fan Code: 71JM/20/6/6/...710 mm 900 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11743

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 5 6 70

50

100

150

200

2500 5000 10000 15000 20000

0 2000 4000 6000 8000 10000 12000 14000

0

5

10

15

20

25

0.0

0.2

0.4

0.6

0.8

1.0

0 1 2 3 4 5 6 70.0

0.2

0.4

0.6

0.8

1.0

1.2

16°

24°

32°

8°16°

24°

32°

81

80

82

83

81

80

86

84

82

82

84

84

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—11—14

—8—9

—4—6

—6—4

—10—7

—17—14

—23—20

—31—28

8—11—14

—7—9

—4—6

—6—4

—10—7

—17—13

—22—20

—28—27

16—13

—8—7—5

—4—6

—7—9

—10—10

—16—13

—23—18

—30—24

16—12

—8—7—5

—4—6

—7—9

—10—10

—16—13

—22—17

—28—22

24 — 36 24 — 36—7—5

—5—4

—6—8

—10—11

—11—13

—14—17

—18—20

—23—25

—6—4

—5—4

—6—8

—10—11

—11—13

—14—17

—17—19

—22—24

JM AEROFOIL

Page 111: JM Aerofoil 50 Hz Technical

Fan Code: 71JM/25/6/6/...710 mm 935 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11745

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 5 60

50

100

150

2000 5000 10000 15000 20000

0 2000 4000 6000 8000 10000 12000

0

5

10

15

20

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0 1 2 3 4 5 60.0

0.2

0.4

0.6

0.8

1.0

79

78

81

81

16°

24°

32°

8°16°

24°

32°

80

81

84

83

82

76

77

85

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—12

—7—10

—9—5—8

—4—7

—10—8

—16—10

—24—17

—31—24

8—10

—5—9—7

—5—8

—4—7

—10—8

—16—9

—24—16

—29—22

16—7—4

—6—6

—7—9

—7—11

—9—13

—14—14

—20—20

—25—25

16—6—2

—5—4

—7—9

—7—11

—9—13

—13—14

—20—20

—24—24

24 — 36 24 — 36—5—4

—6—7

—7—8

—9—11

—12—13

—15—16

—19—21

—21—24

—4—1

—5—5

—7—8

—9—11

—11—13

—14—16

—18—20

—19—23

JM AEROFOIL

Page 112: JM Aerofoil 50 Hz Technical

Fan Code: 71JM/25/6/9/...710 mm 935 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11746

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 5 60

50

100

150

200

2500 5000 10000 15000 20000

0 2000 4000 6000 8000 10000 12000

0

5

10

15

20

25

0.0

0.2

0.4

0.6

0.8

1.0

0 1 2 3 4 5 60.00.20.40.60.81.01.21.4

16°

24°

32°

8° 16°24°

32°

79

78

83

80

79

80

84

82

81

80

80

84

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—11—10

—9—8

—6—8

—5—6

—8—8

—15—8

—24—18

—30—24

8—8—9

—7—6

—6—7

—5—6

—8—8

—14—8

—24—16

—29—23

16—10

—9—8—5

—5—6

—6—9

—9—10

—15—12

—21—18

—27—24

16—9—7

—7—3

—5—6

—6—9

—9—10

—15—12

—21—18

—26—24

24 — 36 24 — 36—8—7

—6—5

—6—6

—8—10

—11—12

—14—15

—18—20

—20—23

—6—4

—4—3

—6—6

—8—10

—10—12

—13—15

—16—19

—18—22

JM AEROFOIL

Page 113: JM Aerofoil 50 Hz Technical

Fan Code: 71JM/20/4/3/...710 mm 1440 rev/min 3 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11747

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 5 6 7 8 90

50

100

150

200

250

300

350

4000 5000 10000 15000 20000 25000 30000

0 5000 10000 15000

0

5

10

15

20

25

30

35

40

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

0 1 2 3 4 5 6 7 8 90.0

0.5

1.0

1.5

2.0

2.5

3.0

16°

24°

32°

8°16°

24°

32°

92

90

91

93

93

91

99

95

93

90

91

92

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—11—5

—15—12

—7—9

—4—9

—9—10

—13—12

—21—17

—27—23

8—8—3

—13—11

—6—8

—3—8

—9—9

—12—10

—19—15

—23—20

16—6—2

—11—9

—6—9

—7—14

—12—16

—13—16

—19—20

—24—24

16—5—1

—11—8

—6—9

—6—14

—11—16

—12—15

—17—18

—21—22

24 — 36 24 — 36—4—2

—9—8

—9—10

—13—14

—13—16

—14—17

—17—21

—22—25

—2—1

—8—8

—8—9

—12—14

—12—16

—13—16

—15—19

—19—22

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

JM AEROFOIL

Page 114: JM Aerofoil 50 Hz Technical

Fan Code: 71JM/20/4/6/...710 mm 1440 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11748

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2 4 6 8 100

100

200

300

400

500

6000 5000 10000 15000 20000 25000 30000

0 5000 10000 15000 20000

0

10

20

30

40

50

60

0.0

0.5

1.0

1.5

2.0

0 2 4 6 8 100.00.51.01.52.02.53.03.54.04.5

16°

24°

32°

8°16°

24°

32°

92

90

92

94

92

91

96

94

93

93

94

94

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—16—18

—11—12

—8—9

—4—5

—8—6

—12—8

—20—17

—26—23

8—15—17

—9—11

—7—9

—4—5

—8—6

—11—7

—19—16

—23—21

16—16—11

—11—6

—6—6

—5—8

—9—10

—11—11

—19—15

—25—20

16—15—11

—10—5

—6—6

—4—7

—9—10

—11—10

—18—14

—23—18

24 — 36 24 — 36—10

—8—6—5

—7—7

—8—10

—12—13

—12—14

—16—19

—20—23

—8—7

—5—4

—7—6

—7—9

—11—13

—12—14

—15—17

—19—21

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

JM AEROFOIL

Page 115: JM Aerofoil 50 Hz Technical

Fan Code: 71JM/25/4/3/...710 mm 1440 rev/min 3 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11749

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 5 6 7 80

50

100

150

200

250

300

3500 5000 10000 15000 20000 25000

0 2000 4000 6000 8000 10000 12000 14000 16000

0

5

10

15

20

25

30

35

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

0 1 2 3 4 5 6 7 80.0

0.5

1.0

1.5

2.0

16°

24°

32°

8°16°

24°

32°

88

87

87

91

90

91

94

93

92

84

84

92

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—12

—4—14

—9—9—9

—4—10

—7—11

—14—14

—20—14

—28—21

8—9—1

—12—7

—9—8

—3—9

—6—11

—13—12

—19—12

—25—19

16—6—3

—8—7

—7—9

—8—11

—11—14

—15—17

—18—18

—21—24

16—3—1

—6—6

—7—9

—8—11

—10—14

—14—16

—17—17

—20—22

24 — 32 24 — 32—4—4

—6—7

—9—10

—11—12

—13—13

—16—16

—19—19

—22—22

—20

—5—5

—8—10

—10—11

—12—13

—15—15

—17—18

—19—20

JM AEROFOIL

Page 116: JM Aerofoil 50 Hz Technical

Fan Code: 71JM/25/4/6/...710 mm 1440 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11750

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 5 6 7 8 90

100

200

300

400

5000 5000 10000 15000 20000 25000 30000

0 5000 10000 15000

0

10

20

30

40

50

0.0

0.5

1.0

1.5

2.0

0 1 2 3 4 5 6 7 8 90.00.51.01.52.02.53.03.54.0

16°

24°

32°

8°16°

24°

32°

89

88

91

91

90

92

94

94

93

86

87

95

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—13

—8—14—11

—10—10

—5—8

—6—8

—13—9

—19—12

—27—20

8—11—7

—11—9

—8—8

—4—8

—5—7

—12—8

—18—10

—25—18

16—8—5

—11—8

—7—7

—8—11

—8—12

—12—14

—17—16

—23—22

16—6—3

—9—7

—6—5

—8—10

—7—11

—10—13

—16—16

—21—21

24 — 36 24 — 32—5—4

—8—7

—8—8

—9—10

—10—12

—14—15

—18—19

—21—23

—3—2

—7—5

—7—7

—8—10

—10—12

—13—15

—16—18

—19—22

JM AEROFOIL

Page 117: JM Aerofoil 50 Hz Technical

Fan Code: 71JM/25/4/9/...710 mm 1440 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11751

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2 4 6 8 100

100

200

300

400

500

6000 5000 10000 15000 20000 25000 30000

0 5000 10000 15000 20000

0

10

20

30

40

50

60

0.0

0.5

1.0

1.5

2.0

0 2 4 6 8 100

1

2

3

4

5

16°

24°

32°

8° 16°24°

32°

89

88

92

91

90

90

95

93

92

89

89

94

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—12—12

—11—11

—10—8

—6—7

—5—7

—11—8

—18—11

—27—21

8—9

—10—9

—10—7—6

—6—7

—4—7

—10—7

—17—9

—25—19

16—10

—8—11—10

—7—6

—5—7

—8—9

—12—12

—17—14

—24—22

16—9—6

—10—9

—6—4

—5—7

—7—9

—11—11

—17—13

—23—21

24 — 36 24 — 36—6—5

—10—9

—7—7

—8—8

—10—11

—13—14

—17—18

—20—23

—4—3

—9—8

—6—5

—7—8

—9—11

—12—14

—15—17

—18—21

JM AEROFOIL

Page 118: JM Aerofoil 50 Hz Technical

Fan Code: 71JM/31/2/9/...710 mm 2910 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11752

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 200

500

1000

1500

2000

25000 10000 20000 30000 40000 50000 60000

0 5000 10000 15000 20000 25000 30000 35000 40000

0

50

100

150

200

250

0

2

4

6

8

10

0 5 10 15 2005

1015202530354045

16°

24°

32°

40°

8° 16°24°

32°

40°

104

104

109

107

106

107

112

110

108

105

104

110

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—13—13

—12—12

—11—11

—10—9

—6—7

—5—7

—12—8

—19—11

8—11—11

—11—11

—10—10

—7—7

—6—7

—4—6

—11—7

—17—9

16—11—8

—11—9

—12—11

—8—7

—6—8

—8—10

—13—13

—19—15

16—9—7

—10—8

—11—10

—6—5

—5—8

—7—10

—12—12

—17—14

24 — 40 24 — 40—6—6

—7—7

—12—11

—8—8

—9—9

—12—13

—15—16

—18—19

—4—4

—6—6

—11—10

—7—6

—8—9

—10—12

—13—14

—16—18

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

JM AEROFOIL

Page 119: JM Aerofoil 50 Hz Technical

Fan Code: 80JM/20/8/3/...800 mm 695 rev/min 3 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11753

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 5 60

20

40

60

80

1000 5000 10000 15000 20000

0 2000 4000 6000 8000 10000 12000

0

2

4

6

8

10

0.00

0.05

0.10

0.15

0.20

0.25

0.30

0.35

0.40

0 1 2 3 4 5 60.0

0.1

0.2

0.3

0.4

0.5

16°

24°

32°

8°16°

24°

32°

75

73

76

77

77

77

84

80

79

72

74

80

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—17—11

—8—8

—3—6

—7—6

—10—8

—18—14

—23—19

—32—27

8—15

—9—8—8

—3—6

—7—6

—10—8

—17—13

—22—18

—29—26

16—9—5

—7—5

—5—9

—9—11

—9—11

—12—13

—15—16

—22—22

16—8—5

—7—5

—5—9

—9—11

—9—11

—12—13

—14—15

—19—20

24 — 36 24 — 36—7—5

—7—6

—9—9

—8—10

—6—9

—11—13

—15—17

—23—25

—6—4

—7—6

—9—9

—8—10

—6—9

—11—13

—14—16

—22—22

JM AEROFOIL

Page 120: JM Aerofoil 50 Hz Technical

Fan Code: 80JM/20/8/6/...800 mm 695 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11754

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 5 6 70

20

40

60

80

100

120

140

1600 5000 10000 15000 20000

0 2000 4000 6000 8000 10000 12000 14000

0

2

4

6

8

10

12

14

16

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0 1 2 3 4 5 6 70.00.10.20.30.40.50.60.70.80.9

16°

24°

32°

8°16°

24°

32°

78

76

78

80

78

78

84

81

80

78

80

81

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—13—14

—7—10

—4—6

—6—5

—9—6

—18—15

—24—21

—32—29

8—12—13

—7—10

—4—6

—6—5

—9—6

—18—14

—23—20

—30—28

16—14

—7—6—6

—3—7

—8—9

—11—9

—19—13

—24—18

—33—24

16—13

—7—6—6

—3—7

—8—9

—11—9

—19—13

—23—17

—31—23

24 — 36 24 — 36—8—5

—7—6

—6—7

—9—11

—8—11

—12—15

—16—18

—23—25

—7—4

—7—6

—6—7

—9—11

—8—11

—12—14

—16—17

—22—23

JM AEROFOIL

Page 121: JM Aerofoil 50 Hz Technical

Fan Code: 80JM/25/8/3/...800 mm 695 rev/min 3 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11755

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 50

10

20

30

40

50

60

70

80

900 5000 10000 15000

0 2000 4000 6000 8000 10000

0

2

4

6

8

0.00

0.05

0.10

0.15

0.20

0.25

0.30

0.35

0 1 2 3 4 50.000.050.100.150.200.250.300.35

16°

24°

32°

8°16°

24°

32°

72

72

72

76

76

77

79

78

78

71

74

80

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—15

—8—10

—8—3—6

—5—6

—13—10

—18—11

—24—16

—34—23

8—13

—7—10

—8—3—6

—6—7

—13—11

—18—10

—24—15

—31—21

16—6—5

—7—7

—7—7

—7—9

—11—12

—13—14

—16—17

—22—23

16—5—4

—7—7

—7—7

—8—9

—11—13

—13—13

—15—16

—20—21

24 — 32 24 — 32—5—5

—7—8

—8—7

—8—7

—12—10

—15—13

—19—17

—24—22

—4—5

—7—8

—8—7

—9—8

—12—11

—15—13

—17—15

—23—19

JM AEROFOIL

Page 122: JM Aerofoil 50 Hz Technical

Fan Code: 80JM/25/8/6/...800 mm 695 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11756

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 5 6 70

20

40

60

80

100

120

1400 5000 10000 15000 20000

0 2000 4000 6000 8000 10000 12000 14000

0

2

4

6

8

10

12

14

0.0

0.1

0.2

0.3

0.4

0.5

0 1 2 3 4 5 6 70.00.10.20.30.40.50.60.7

16°

24°

32°

8°16°

24°

32°

75

75

80

78

78

79

81

79

79

76

78

84

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—16—14

—11—11

—4—7

—3—4

—12—7

—18—12

—25—18

—34—27

8—14—14

—11—11

—4—7

—4—5

—13—8

—18—11

—24—18

—32—26

16—12

—8—8—4

—7—8

—4—8

—10—11

—15—14

—21—18

—29—24

16—11—8

—8—4

—7—8

—4—9

—11—11

—15—13

—21—17

—28—23

24 — 36 24 — 36—7—7

—7—7

—7—7

—6—7

—11—11

—14—14

—17—18

—23—23

—7—6

—7—7

—7—7

—7—7

—11—12

—14—14

—17—17

—22—22

JM AEROFOIL

Page 123: JM Aerofoil 50 Hz Technical

Fan Code: 80JM/25/8/9/...800 mm 695 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11757

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 5 6 70

20

40

60

80

100

120

140

160

1800 5000 10000 15000 20000

0 2000 4000 6000 8000 10000 12000 14000

0

5

10

15

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0 1 2 3 4 5 6 70.0

0.2

0.4

0.6

0.8

1.0

16°

24°

32°

8° 16°24°

32°

78

78

80

79

78

78

81

79

78

80

79

82

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—10—10

—9—8

—6—7

—4—6

—10—8

—17—10

—26—20

—34—27

8—9

—10—7—7

—6—7

—5—8

—10—8

—17—8

—25—19

—32—26

16—10—11

—6—6

—5—5

—6—7

—12—11

—17—14

—22—19

—30—26

16—9

—10—6—6

—5—5

—7—8

—12—11

—17—14

—21—19

—28—25

24 — 36 24 — 36—11—9

—8—7

—6—5

—5—7

—10—11

—13—14

—17—18

—22—24

—9—9

—8—6

—6—5

—6—7

—10—12

—13—14

—16—17

—20—22

JM AEROFOIL

Page 124: JM Aerofoil 50 Hz Technical

Fan Code: 80JM/20/6/3/...800 mm 935 rev/min 3 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11758

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 5 6 7 80

20

40

60

80

100

120

140

160

1800 5000 10000 15000 20000 25000

0 2000 4000 6000 8000 10000 12000 14000 16000

0

5

10

15

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0 1 2 3 4 5 6 7 80.0

0.2

0.4

0.6

0.8

1.0

1.2

16°

24°

32°

8°16°

24°

32°

82

80

82

84

84

83

91

87

85

81

82

86

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—16

—9—10

—9—3—7

—7—6

—9—7

—17—13

—22—18

—29—24

8—14

—8—10

—9—3—7

—7—6

—9—7

—16—12

—21—17

—26—23

16—8—4

—8—6

—6—8

—8—12

—9—11

—12—14

—14—16

—20—21

16—6—3

—8—6

—6—8

—8—12

—9—11

—12—14

—13—15

—18—19

24 — 36 24 — 36—6—4

—8—6

—9—9

—9—11

—6—10

—11—14

—14—17

—21—23

—5—3

—8—6

—10—9

—9—11

—6—10

—11—13

—13—15

—19—21

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

JM AEROFOIL

Page 125: JM Aerofoil 50 Hz Technical

Fan Code: 80JM/20/6/6/...800 mm 935 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11759

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 5 6 7 8 90

50

100

150

200

250

3000 5000 10000 15000 20000 25000 30000

0 5000 10000 15000

0

5

10

15

20

25

30

0.0

0.2

0.4

0.6

0.8

1.0

1.2

0 1 2 3 4 5 6 7 8 90.0

0.5

1.0

1.5

2.0

2.5

16°

24°

32°

8°16°

24°

32°

86

84

85

86

85

84

90

87

86

85

87

88

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—15—16

—8—10

—4—7

—6—5

—8—5

—17—14

—22—19

—28—26

8—14—16

—8—10

—4—7

—6—5

—8—5

—16—13

—21—19

—26—24

16—15

—9—7—6

—3—6

—8—9

—10—8

—18—13

—23—16

—29—22

16—14

—9—7—5

—3—6

—8—9

—10—8

—18—13

—22—16

—27—20

24 — 36 24 — 36—9—6

—6—5

—6—7

—9—11

—8—10

—12—15

—15—17

—21—23

—8—6

—6—4

—6—7

—9—11

—8—10

—12—14

—14—16

—20—21

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

JM AEROFOIL

Page 126: JM Aerofoil 50 Hz Technical

Fan Code: 80JM/25/6/6/...800 mm 935 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11761

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 5 6 7 8 90

50

100

150

200

2500 5000 10000 15000 20000 25000 30000

0 5000 10000 15000

0

5

10

15

20

25

0.0

0.2

0.4

0.6

0.8

1.0

0 1 2 3 4 5 6 7 8 90.00.20.40.60.81.01.21.41.61.8

16°

24°

32°

8°16°

24°

32°

84

84

88

84

84

85

88

86

86

82

84

90

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—15—10

—13—13

—6—8

—3—5

—9—6

—17—11

—23—17

—31—25

8—14—10

—12—12

—6—8

—4—6

—10—7

—17—10

—22—17

—29—23

16—7—4

—8—5

—8—9

—4—11

—10—13

—15—15

—21—19

—28—25

16—5—4

—8—5

—8—9

—5—11

—10—13

—15—15

—20—18

—26—23

24 — 36 24 — 36—6—5

—7—7

—7—7

—7—8

—10—11

—14—15

—17—17

—22—22

—5—4

—7—7

—8—7

—8—9

—10—12

—14—15

—16—16

—20—21

JM AEROFOIL

Page 127: JM Aerofoil 50 Hz Technical

Fan Code: 80JM/25/6/9/...800 mm 935 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11762

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 5 6 7 8 90

50

100

150

200

250

3000 5000 10000 15000 20000 25000 30000

0 5000 10000 15000

0

5

10

15

20

25

30

0.0

0.2

0.4

0.6

0.8

1.0

1.2

0 1 2 3 4 5 6 7 8 90.0

0.5

1.0

1.5

2.0

2.5

16°

24°

32°

8° 16°24°

32°

85

84

86

85

85

85

88

85

85

86

85

88

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—11—10

—9—8

—6—8

—5—6

—8—8

—15—8

—24—18

—30—24

8—9

—10—7—7

—6—8

—6—8

—9—8

—15—7

—24—17

—28—23

16—9

—10—8—7

—5—5

—6—8

—10—9

—16—13

—21—18

—27—24

16—8—9

—8—6

—5—5

—6—9

—10—9

—16—13

—20—17

—25—23

24 — 36 24 — 36—10

—9—9—7

—6—5

—6—7

—10—11

—13—14

—16—18

—20—23

—8—8

—8—6

—6—5

—7—8

—10—11

—13—14

—15—17

—19—21

JM AEROFOIL

Page 128: JM Aerofoil 50 Hz Technical

Fan Code: 80JM/20/4/3/...800 mm 1440 rev/min 3 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11763

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2 4 6 8 10 12 140

50

100

150

200

250

300

350

400

4500 10000 20000 30000 40000

0 5000 10000 15000 20000 25000

0

10

20

30

40

0.0

0.5

1.0

1.5

0 2 4 6 8 10 12 140.00.51.01.52.02.53.03.54.04.5

16°

24°

32°

8°16°

24°

32°

93

91

92

95

95

94

103

98

96

92

92

96

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—16

—8—17—12

—8—9

—3—7

—8—7

—11—8

—19—15

—24—20

8—13

—7—16—12

—8—9

—3—6

—8—7

—10—7

—17—14

—21—18

16—7—4

—10—8

—8—7

—6—11

—10—13

—10—13

—13—15

—17—19

16—6—3

—10—7

—8—7

—6—11

—10—13

—10—12

—12—14

—14—16

24 — 36 24 — 36—6—4

—9—8

—9—8

—10—11

—9—12

—8—11

—13—16

—17—20

—5—3

—8—7

—9—8

—10—11

—9—12

—7—11

—11—14

—15—17

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

JM AEROFOIL

Page 129: JM Aerofoil 50 Hz Technical

Fan Code: 80JM/20/4/6/...800 mm 1440 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11764

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2 4 6 8 10 12 140

100

200

300

400

500

600

7000 10000 20000 30000 40000

0 5000 10000 15000 20000 25000

0

10

20

30

40

50

60

70

0.0

0.5

1.0

1.5

2.0

2.5

0 2 4 6 8 10 12 14012345678

16°

24°

32°

8°16°

24°

32°

95

93

94

96

95

94

100

98

96

95

97

97

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—21—21

—14—14

—8—10

—5—6

—7—5

—10—7

—19—16

—24—21

8—19—21

—12—13

—7—10

—4—6

—7—5

—10—5

—18—15

—22—19

16—19—12

—14—7

—6—6

—4—7

—9—9

—12—9

—20—14

—25—18

16—18—11

—14—7

—6—6

—3—7

—9—9

—11—9

—18—13

—23—17

24 — 36 24 — 36—12

—9—8—6

—8—6

—6—8

—10—12

—9—11

—13—15

—17—19

—11—9

—8—5

—7—6

—6—8

—9—12

—9—11

—12—14

—16—17

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

JM AEROFOIL

Page 130: JM Aerofoil 50 Hz Technical

Fan Code: 80JM/25/4/3/...800 mm 1440 rev/min 3 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11765

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2 4 6 8 10 120

50

100

150

200

250

300

350

4000 5000 10000 15000 20000 25000 30000 35000 40000

0 5000 10000 15000 20000 25000

0

5

10

15

20

25

30

35

40

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

0 2 4 6 8 10 120.00.51.01.52.02.53.03.5

16°

24°

32°

8°16°

24°

32°

91

91

90

93

93

94

97

96

95

88

90

96

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—11—4

—16—11

—11—10

—4—8

—5—8

—14—12

—19—14

—25—18

8—8—3

—15—10

—10—10

—5—9

—6—8

—13—11

—18—13

—23—16

16—4—2

—9—9

—9—11

—9—11

—10—12

—13—16

—16—17

—18—21

16—4—1

—9—9

—9—11

—9—11

—10—12

—12—15

—14—16

—16—19

24 — 32 24 — 32—5—4

—7—8

—9—10

—9—9

—10—9

—14—13

—17—16

—21—19

—4—3

—6—7

—9—10

—10—10

—10—10

—13—12

—16—14

—19—16

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

JM AEROFOIL

Page 131: JM Aerofoil 50 Hz Technical

Fan Code: 80JM/25/4/6/...800 mm 1440 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11767

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2 4 6 8 10 12 140

100

200

300

400

500

6000 10000 20000 30000 40000

0 5000 10000 15000 20000 25000

0

10

20

30

40

50

60

0.0

0.5

1.0

1.5

2.0

0 2 4 6 8 10 12 1401234567

16°

24°

32°

8°16°

24°

32°

93

93

97

94

94

95

98

97

96

92

93

99

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—15—10

—17—15

—11—12

—4—7

—4—4

—13—8

—19—13

—26—19

8—14—10

—15—14

—11—12

—5—9

—4—4

—12—7

—18—13

—23—18

16—8—5

—14—11

—8—6

—7—10

—5—10

—12—13

—17—16

—23—20

16—7—4

—14—10

—8—6

—8—10

—5—10

—12—13

—16—15

—21—19

24 — 36 24 — 36—5—5

—9—9

—9—9

—8—8

—7—9

—12—13

—16—16

—19—20

—4—5

—9—8

—9—8

—9—9

—8—9

—12—13

—15—15

—18—18

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

JM AEROFOIL

Page 132: JM Aerofoil 50 Hz Technical

Fan Code: 80JM/25/4/9/...800 mm 1440 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11769

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2 4 6 8 10 12 140

100

200

300

400

500

600

700

8000 10000 20000 30000 40000

0 5000 10000 15000 20000 25000

0

10

20

30

40

50

60

70

80

0.0

0.5

1.0

1.5

2.0

2.5

3.0

0 2 4 6 8 10 12 140123456789

16°

24°

32°

8° 16°24°

32°

95

94

97

95

95

95

98

96

96

96

95

98

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—10—10

—11—11

—10—9

—6—7

—5—7

—11—8

—18—11

—27—21

8—9

—10—11—11

—8—8

—7—8

—5—7

—10—7

—17—10

—24—19

16—8—7

—11—12

—7—7

—6—6

—7—8

—13—12

—18—15

—23—21

16—6—7

—11—12

—7—7

—6—6

—7—8

—13—12

—17—15

—21—19

24 — 36 24 — 36—5—6

—13—11

—10—8

—7—6

—7—8

—12—13

—15—16

—19—20

—3—5

—13—11

—10—8

—8—6

—7—8

—12—13

—14—15

—18—18

If it is intended to run this fan in reverse for other than emergency operation, please refer to Fl kt Woods Ltd.

JM AEROFOIL

Page 133: JM Aerofoil 50 Hz Technical

Fan Code: 80JM/31/2/9/...800 mm 2910 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11772

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 300

500

1000

1500

2000

2500

30000 20000 40000 60000 80000 100000

0 10000 20000 30000 40000 50000 60000

0

50

100

150

200

250

300

0

2

4

6

8

10

12

0 5 10 15 20 25 300

1020304050607080

16°

24°

32°

8° 16°24°

32°

110

110

115

111

111

112

115

112

112

111

110

115

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—10—11

—10—10

—12—12

—10—10

—6—7

—5—7

—12—9

—19—12

8—9

—11—10—10

—11—11

—8—9

—6—7

—5—6

—11—8

—17—10

16—7—7

—8—8

—12—13

—7—8

—7—7

—8—9

—14—13

—19—17

16—6—7

—8—8

—12—13

—7—8

—7—7

—8—9

—14—13

—17—15

24 — 36 24 — 36—5—7

—6—7

—15—13

—12—9

—9—7

—9—9

—14—14

—17—17

—4—6

—6—7

—15—12

—12—8

—9—7

—9—9

—13—13

—16—15

If it is intended to run this fan in reverse for other than emergency operation, please refer to Fl kt Woods Ltd.

JM AEROFOIL

Page 134: JM Aerofoil 50 Hz Technical

Fan Code: 90JM/25/8/3/...900 mm 695 rev/min 3 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11773

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 5 6 7 80

20

40

60

80

1000 5000 10000 15000 20000 25000

0 2000 4000 6000 8000 10000 12000 14000 16000

0

2

4

6

8

10

0.00

0.05

0.10

0.15

0.20

0.25

0.30

0.35

0.40

0 1 2 3 4 5 6 7 80.0

0.1

0.2

0.3

0.4

0.5

0.6

16°

24°

32°

8°16°

24°

32°

79

78

77

82

81

81

85

83

83

75

76

82

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—14

—7—12

—9—5—7

—4—7

—10—9

—15—11

—21—16

—29—22

8—12

—6—11—9

—5—7

—4—7

—10—9

—15—10

—20—15

—26—20

16—6—4

—8—7

—7—8

—7—9

—10—11

—12—13

—15—17

—20—22

16—4—3

—8—7

—7—8

—7—9

—10—11

—12—13

—14—16

—18—20

24 — 32 24 — 32—5—5

—7—8

—7—8

—9—8

—11—10

—14—13

—18—16

—23—21

—4—4

—7—8

—7—8

—9—8

—11—10

—14—12

—17—15

—21—19

JM AEROFOIL

Page 135: JM Aerofoil 50 Hz Technical

Fan Code: 90JM/25/8/6/...900 mm 695 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11774

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 1 2 3 4 5 6 7 8 90

20

40

60

80

100

120

140

1600 5000 10000 15000 20000 25000 30000

0 5000 10000 15000

0

2

4

6

8

10

12

14

16

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0 1 2 3 4 5 6 7 8 90.0

0.2

0.4

0.6

0.8

1.0

16°

24°

32°

8°16°

24°

32°

80

80

84

83

82

83

86

84

85

79

81

85

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—16—12

—12—10

—5—9

—4—5

—9—6

—15—10

—22—16

—31—24

8—14—11

—12—10

—5—9

—4—5

—10—6

—15—9

—21—16

—28—22

16—13

—7—11—6

—6—8

—3—7

—9—9

—14—12

—20—17

—28—23

16—12

—7—11—6

—6—8

—3—7

—9—9

—14—12

—19—16

—26—21

24 — 32 24 — 32—8—6

—7—7

—7—7

—6—8

—10—10

—13—13

—17—17

—22—22

—7—5

—7—7

—7—7

—6—8

—10—10

—13—13

—16—16

—21—20

JM AEROFOIL

Page 136: JM Aerofoil 50 Hz Technical

Fan Code: 90JM/25/8/9/...900 mm 695 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11775

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2 4 6 8 100

50

100

150

200

2500 5000 10000 15000 20000 25000 30000

0 5000 10000 15000 20000

0

5

10

15

20

25

0.0

0.2

0.4

0.6

0.8

1.0

0 2 4 6 8 100.00.20.40.60.81.01.21.41.6

16°

24°

32°

8°16°

24°

32°

82

81

84

84

83

82

86

84

84

82

82

85

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—15—14

—10—8

—7—8

—4—6

—7—6

—13—9

—22—17

—30—24

8—14—14

—9—7

—7—8

—4—6

—7—6

—13—8

—21—16

—28—22

16—13—10

—8—6

—6—6

—5—6

—9—9

—14—12

—20—18

—28—24

16—11—10

—8—6

—6—6

—5—6

—9—9

—14—12

—19—17

—26—22

24 — 36 24 — 36—9—8

—7—6

—7—6

—6—8

—9—10

—12—13

—16—17

—21—23

—8—7

—7—6

—7—6

—6—8

—9—10

—12—13

—15—16

—20—21

JM AEROFOIL

Page 137: JM Aerofoil 50 Hz Technical

Fan Code: 90JM/25/6/3/...900 mm 935 rev/min 3 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11777

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2 4 6 8 100

20

40

60

80

100

120

140

160

1800 5000 10000 15000 20000 25000 30000

0 5000 10000 15000 20000

0

5

10

15

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0 2 4 6 8 100.00.20.40.60.81.01.21.4

16°

24°

32°

8°16°

24°

32°

89

87

86

89

88

89

92

91

90

82

83

88

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—11—4

—14—10

—6—8

—4—8

—8—9

—14—12

—20—15

—27—21

8—8—2

—13—10

—6—8

—4—8

—8—9

—14—10

—19—15

—24—19

16—3—2

—10—10

—9—10

—9—12

—11—13

—13—16

—16—18

—20—23

16—1—1

—10—10

—9—10

—9—12

—11—13

—13—15

—15—17

—18—21

24 — 32 24 — 32—4—4

—7—8

—8—9

—10—10

—11—10

—14—13

—18—16

—22—20

—3—2

—7—8

—8—9

—10—10

—11—10

—14—13

—17—15

—20—18

JM AEROFOIL

Page 138: JM Aerofoil 50 Hz Technical

Fan Code: 90JM/25/6/6/...900 mm 935 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11778

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2 4 6 8 10 120

50

100

150

200

250

3000 5000 10000 15000 20000 25000 30000 35000 40000

0 5000 10000 15000 20000 25000

0

5

10

15

20

25

30

0.0

0.2

0.4

0.6

0.8

1.0

1.2

0 2 4 6 8 10 120.0

0.5

1.0

1.5

2.0

2.5

16°

24°

32°

8°16°

24°

32°

87

87

90

90

89

89

92

91

91

85

87

91

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—16—10

—14—12

—6—8

—3—7

—8—5

—14—9

—20—15

—27—21

8—14—10

—13—11

—6—8

—3—7

—8—5

—14—8

—20—14

—25—20

16—11—5

—12—7

—8—8

—4—8

—7—9

—13—12

—19—16

—25—22

16—9—5

—12—7

—8—8

—4—8

—7—9

—13—12

—18—16

—24—20

24 — 32 24 — 32—7—5

—8—7

—7—8

—7—8

—9—10

—13—13

—16—17

—21—21

—5—4

—8—7

—7—8

—7—8

—9—10

—13—13

—15—16

—20—19

JM AEROFOIL

Page 139: JM Aerofoil 50 Hz Technical

Fan Code: 90JM/25/6/9/...900 mm 935 rev/min 9 Blades 50 Hz

21/02/00SK11779

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D -- Ducted inlet, Ducted outlet. Performance ratings do not include theeffects of appurtenances.

0 2 4 6 8 10 12 140

50

100

150

200

250

300

350

4000 10000 20000 30000 40000

0 5000 10000 15000 20000 25000

0

5

10

15

20

25

30

35

40

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

0 2 4 6 8 10 12 140.00.51.01.52.02.53.03.54.0

16¡

24¡

32¡

8¡16¡

24¡

32¡

88

87

90

90

89

89

93

91

90

88

88

91

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8--15--14

--11--8

--8--9

--4--7

--6--6

--12--8

--20--15

--26--21

8--14--14

--9--7

--8--9

--4--7

--6--6

--11--7

--19--15

--24--20

16--12--10

--9--6

--7--7

--4--7

--7--8

--12--12

--18--16

--25--22

16--11--9

--9--6

--7--7

--4--7

--7--8

--12--11

--17--16

--23--20

24 -- 36--9--7

--8--6

--7--7

--6--8

--8--10

--11--13

--15--16

--19--21

24 -- 36--7--7

--8--6

--7--7

--6--8

--8--10

--11--13

--14--15

--18--19

BS 5750 Pt 1EN 29001ISO 9001

JM AEROFOIL

Page 140: JM Aerofoil 50 Hz Technical

Fan Code: 90JM/25/4/3/...900 mm 1440 rev/min 3 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11781

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2 4 6 8 10 12 14 160

50

100

150

200

250

300

350

400

4500 10000 20000 30000 40000 50000

0 5000 10000 15000 20000 25000 30000

0

10

20

30

40

0.0

0.5

1.0

1.5

0 2 4 6 8 10 12 14 160

1

2

3

4

5

6

16°

24°

32°

8°16°

24°

32°

101

98

96

99

99

99

103

102

101

92

93

98

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—10

—4—16—11

—12—11

—5—9

—5—9

—11—11

—17—14

—23—18

8—7—2

—14—10

—12—11

—5—9

—5—9

—10—9

—15—13

—19—16

16—3—3

—10—9

—11—12

—11—12

—11—13

—13—16

—16—18

—19—21

16—2—1

—9—8

—11—11

—10—12

—10—13

—12—15

—14—16

—16—19

24 — 32 24 — 32—5—4

—7—8

—9—10

—9—10

—11—11

—13—13

—16—16

—20—19

—4—2

—7—7

—9—10

—9—10

—10—11

—12—12

—15—14

—18—16

If it is intended to run this fan in reverse for other than emergency operation, please refer to Fl kt Woods Ltd.

JM AEROFOIL

Page 141: JM Aerofoil 50 Hz Technical

Fan Code: 90JM/25/4/6/...900 mm 1440 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11782

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2 4 6 8 10 12 14 16 180

100

200

300

400

500

600

7000 10000 20000 30000 40000 50000 60000

0 5000 10000 15000 20000 25000 30000 35000

0

10

20

30

40

50

60

70

0.0

0.5

1.0

1.5

2.0

2.5

0 2 4 6 8 10 12 14 16 180123456789

16°

24°

32°

8°16°

24°

32°

98

97

100

100

100

99

103

102

102

95

97

101

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—14

—9—17—14

—12—12

—5—10

—4—7

—10—7

—17—12

—23—18

8—13

—8—15—12

—11—11

—5—9

—4—6

—10—5

—15—10

—20—16

16—10

—6—15—10

—11—8

—7—10

—4—9

—10—12

—16—15

—21—19

16—9—5

—14—9

—11—8

—7—9

—4—9

—9—10

—14—13

—19—17

—6—5

—9—8

—9—9

—8—9

—8—10

—11—12

—15—15

—18—19

—5—4

—9—8

—8—8

—8—9

—7—9

—11—12

—14—14

—17—17

24 — 3224 — 32

If it is intended to run this fan in reverse for other than emergency operation, please refer to Fl kt Woods Ltd.

JM AEROFOIL

Page 142: JM Aerofoil 50 Hz Technical

Fan Code: 90JM/25/4/9/...900 mm 1440 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11783

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 200

100

200

300

400

500

600

700

800

9000 10000 20000 30000 40000 50000 60000

0 5000 10000 15000 20000 25000 30000 35000 40000

0

20

40

60

80

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

0 5 10 15 2002468

101214

16°

24°

32°

8°16°

24°

32°

98

97

100

100

99

99

104

101

100

98

98

101

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—16—14

—16—15

—11—8

—8—9

—4—7

—8—7

—15—10

—23—18

8—14—14

—15—14

—9—7

—7—8

—4—6

—7—5

—13—9

—20—16

16—12

—9—14—12

—9—7

—7—7

—6—8

—10—10

—15—14

—21—19

16—10

—8—13—11

—8—6

—6—7

—5—7

—9—9

—13—13

—19—17

24 — 36 24 — 36—7—6

—11—9

—9—8

—8—8

—8—9

—10—12

—14—15

—17—19

—5—6

—10—9

—8—7

—8—7

—7—9

—10—11

—13—14

—16—17

If it is intended to run this fan in reverse for other than emergency operation, please refer to Fl kt Woods Ltd.

JM AEROFOIL

Page 143: JM Aerofoil 50 Hz Technical

Fan Code: 100JM/25/8/3/...1000 mm 695 rev/min 3 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11785

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2 4 6 8 100

20

40

60

80

100

1200 5000 10000 15000 20000 25000 30000

0 5000 10000 15000 20000

0

2

4

6

8

10

12

0.0

0.1

0.2

0.3

0.4

0 2 4 6 8 100.0

0.2

0.4

0.6

0.8

1.0

16°

24°

32°

8°16°

24°

32°

81

80

79

89

86

84

89

87

86

77

76

83

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—14

—7—13

—9—6—8

—4—7

—7—7

—13—11

—18—15

—26—20

8—12

—5—13

—9—6—8

—4—7

—7—7

—12—9

—17—14

—23—19

16—5—4

—9—8

—8—9

—8—9

—9—11

—11—13

—15—17

—19—21

16—4—3

—9—8

—8—9

—8—9

—9—11

—11—13

—13—15

—16—19

24 — 32 24 — 32—6—4

—7—8

—8—9

—9—9

—10—10

—13—13

—18—16

—22—20

—4—3

—7—8

—8—9

—9—9

—10—10

—13—12

—16—15

—20—18

JM AEROFOIL

Page 144: JM Aerofoil 50 Hz Technical

Fan Code: 100JM/25/8/6/...1000 mm 695 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11786

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2 4 6 8 10 120

20

40

60

80

100

120

140

160

1800 5000 10000 15000 20000 25000 30000 35000 40000

0 5000 10000 15000 20000 25000

0

5

10

15

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0 2 4 6 8 10 120.00.20.40.60.81.01.21.41.6

16°

24°

32°

8°16°

24°

32°

82

82

86

88

87

86

91

90

90

81

84

86

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—16—10

—13—10

—6—11

—4—7

—7—5

—13—8

—19—14

—27—21

8—14—10

—13—10

—6—11

—4—7

—7—5

—13—7

—19—14

—25—20

16—15

—7—13

—8—7—8

—3—7

—7—8

—14—11

—20—16

—27—22

16—13

—7—13

—8—7—8

—3—7

—7—8

—14—11

—19—15

—26—21

24 — 32 24 — 32—8—5

—8—7

—7—8

—7—9

—9—9

—13—13

—17—16

—23—21

—7—4

—8—7

—7—8

—7—9

—9—9

—13—12

—16—15

—21—20

JM AEROFOIL

Page 145: JM Aerofoil 50 Hz Technical

Fan Code: 100JM/25/8/9/...1000 mm 695 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11787

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2 4 6 8 10 12 140

50

100

150

200

2500 10000 20000 30000 40000

0 5000 10000 15000 20000 25000

0

5

10

15

20

25

0.0

0.2

0.4

0.6

0.8

1.0

0 2 4 6 8 10 12 140.0

0.5

1.0

1.5

2.0

2.5

3.0

16°

24°

32°

8°16°

24°

32°

86

85

88

89

88

87

92

90

89

84

84

88

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—20—18

—14—10

—9—10

—4—7

—5—4

—11—8

—18—14

—27—21

8—19—18

—13—10

—9—10

—4—7

—5—4

—10—7

—17—14

—25—20

16—16—10

—12—7

—7—8

—4—6

—6—8

—11—11

—18—16

—27—23

16—15—10

—12—7

—7—8

—4—6

—6—8

—11—11

—17—15

—25—21

24 — 36 24 — 36—8—6

—7—6

—8—8

—7—9

—8—9

—11—13

—15—17

—21—22

—7—6

—7—5

—8—8

—7—9

—8—9

—11—12

—15—16

—20—21

JM AEROFOIL

Page 146: JM Aerofoil 50 Hz Technical

Fan Code: 100JM/25/6/3/...1000 mm 935 rev/min 3 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11792

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2 4 6 8 10 12 140

50

100

150

2000 10000 20000 30000 40000

0 5000 10000 15000 20000 25000

0

5

10

15

20

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0 2 4 6 8 10 12 140.0

0.5

1.0

1.5

2.0

2.5

97

93

90

95

16°

24°

32°

8°16°

24°

32°

94

93

99

96

95

87

86

90

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—11—4

—15—11

—8—9

—4—9

—6—8

—12—11

—17—15

—23—19

8—8—2

—14—11

—8—9

—4—9

—6—8

—12—10

—16—14

—20—18

16—3—2

—11—10

—10—11

—10—12

—10—12

—13—15

—16—18

—19—22

16—1—1

—11—10

—10—11

—10—12

—10—12

—12—14

—14—17

—17—19

24 — 32 24 — 32—5—3

—7—9

—8—9

—10—11

—10—10

—13—13

—17—17

—20—19

—3—2

—7—9

—8—9

—10—11

—10—10

—13—12

—16—15

—19—17

JM AEROFOIL

Page 147: JM Aerofoil 50 Hz Technical

Fan Code: 100JM/25/6/6/...1000 mm 950 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11793

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2 4 6 8 10 12 14 160

50

100

150

200

250

300

3500 10000 20000 30000 40000 50000

0 5000 10000 15000 20000 25000 30000

0

5

10

15

20

25

30

35

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

0 2 4 6 8 10 12 14 160.00.51.01.52.02.53.03.54.0

16°

24°

32°

8°16°

24°

32°

92

92

94

96

94

93

98

97

97

89

91

94

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—16

—9—15—12

—7—9

—4—9

—6—5

—12—8

—18—13

—24—19

8—14

—9—14—11

—7—9

—4—9

—6—5

—12—7

—17—13

—22—18

16—14

—6—15

—9—8—8

—4—7

—5—7

—12—11

—18—15

—24—20

16—13

—6—15

—9—8—8

—4—7

—5—7

—12—10

—17—14

—22—19

24 — 32 24 — 32—7—5

—9—8

—7—8

—7—9

—8—9

—12—12

—16—16

—20—20

—6—4

—9—8

—7—8

—7—9

—8—9

—12—12

—15—15

—19—18

JM AEROFOIL

Page 148: JM Aerofoil 50 Hz Technical

BS 5750 Pt 1

EN 29001

ISO 9001

04/03/99SK11794

0 2 4 6 8 10 12 14 16 180

50

100

150

200

250

300

350

400

4500 10000 20000 30000 40000 50000 60000

0 5000 10000 15000 20000 25000 30000 35000

0

10

20

30

40

0.0

0.5

1.0

1.5

0 2 4 6 8 10 12 14 16 180

1

2

3

4

5

6

7

8°�

16°�

24°�

32°�

�16°�

24°�

32°�

92

91

95

96

95

94

100

97

96

91

92

95

ISO 5801

Type D

V

63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k

8Ð21

Ð18

Ð14

Ð10

Ð11

Ð10

Ð4

Ð8

Ð4

Ð4

Ð9

Ð8

Ð17

Ð13

Ð23

Ð188

Ð20

Ð18

Ð12

Ð8

Ð11

Ð10

Ð4

Ð8

Ð4

Ð4

Ð9

Ð6

Ð16

Ð13

Ð21

Ð17

16Ð16

Ð10

Ð12

Ð7

Ð10

Ð8

Ð4

Ð6

Ð6

Ð7

Ð10

Ð11

Ð17

Ð15

Ð24

Ð2016

Ð14

Ð10

Ð12

Ð7

Ð10

Ð8

Ð4

Ð6

Ð6

Ð7

Ð10

Ð10

Ð16

Ð14

Ð22

Ð19

24 Ð 36Ð8

Ð6

Ð8

Ð6

Ð8

Ð8

Ð7

Ð9

Ð7

Ð9

Ð11

Ð12

Ð15

Ð16

Ð19

Ð2024 Ð 36

Ð7

Ð5

Ð7

Ð6

Ð8

Ð8

Ð7

Ð9

Ð7

Ð9

Ð11

Ð12

Ð14

Ð15

Ð18

Ð18

Air Density 1.2 kg/m3

Fan Code: 1000 mm 950 rev/min 6 Blades 50 Hz

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformanceshownis for installationstypeDÐDucted inlet,Ductedoutlet.Performanceratingsdonot includetheeffectsofappurtenances.

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory

specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use

upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet LevelsOctave Band Centre Frequency (Hz) Octave Band Centre Frequency (Hz)Pitch

AnglePitchAngle

100JM/25/6/9/...

JM AEROFOIL

Page 149: JM Aerofoil 50 Hz Technical

Fan Code: 100JM/25/4/3/...1000 mm 1440 rev/min 3 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11799

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 250

100

200

300

400

5000 20000 40000 60000 80000

0 10000 20000 30000 40000 50000

0

10

20

30

40

50

0.0

0.5

1.0

1.5

2.0

0 5 10 15 20 250123456789

16°

24°

32°

8°16°

24°

32°

112

105

102

105

104

104

111

108

106

97

97

100

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—9—3

—16—10

—14—13

—7—11

—5—10

—9—10

—14—14

—20—18

8—6—2

—14—10

—14—12

—7—11

—4—10

—8—9

—13—13

—16—16

16—2—2

—10—9

—14—13

—13—14

—12—14

—13—15

—16—18

—19—21

16—1—1

—10—9

—14—13

—13—14

—12—14

—13—15

—14—17

—16—19

24 — 32 24 — 32—5—3

—8—8

—9—11

—9—11

—11—12

—12—13

—16—16

—19—19

—4—2

—7—7

—9—11

—9—11

—11—12

—12—12

—14—14

—17—17

If it is intended to run this fan in reverse for other than emergency operation, please refer to Fl kt Woods Ltd.

JM AEROFOIL

Page 150: JM Aerofoil 50 Hz Technical

Fan Code: 100JM/25/4/6/...1000 mm 1450 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11800

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 250

100

200

300

400

500

600

700

8000 20000 40000 60000 80000

0 10000 20000 30000 40000 50000

0

10

20

30

40

50

60

70

80

0.0

0.5

1.0

1.5

2.0

2.5

3.0

0 5 10 15 20 2502468

101214

16°

24°

32°

8°16°

24°

32°

103

102

104

107

105

104

109

107

107

100

101

103

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—13

—7—17—12

—13—12

—6—12

—5—8

—8—6

—14—10

—20—16

8—12

—6—15—11

—12—11

—6—12

—4—8

—8—5

—13—9

—18—14

16—10

—5—15

—9—13—10

—7—10

—4—8

—8—10

—15—13

—20—18

16—9—4

—15—9

—13—10

—7—10

—4—8

—8—9

—14—12

—18—16

24 — 32 24 — 32—7—5

—9—7

—9—9

—8—10

—8—11

—10—11

—14—15

—18—18

—6—4

—9—7

—8—9

—7—10

—8—10

—10—11

—13—14

—17—16

If it is intended to run this fan in reverse for other than emergency operation, please refer to Fl kt Woods Ltd.

JM AEROFOIL

Page 151: JM Aerofoil 50 Hz Technical

Fan Code: 100JM/25/4/9/...1000 mm 1470 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11801

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 300

200

400

600

800

1000

12000 20000 40000 60000 80000 100000

0 10000 20000 30000 40000 50000 60000

0

20

40

60

80

100

120

0

1

2

3

4

0 5 10 15 20 25 300

5

10

15

20

25

16°

24°

32°

8°16°

24°

32°

102

101

104

106

105

104

110

107

106

101

101

104

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—21—17

—21—18

—14—10

—9—10

—4—6

—6—5

—12—9

—19—15

8—20—17

—20—18

—13—9

—9—10

—4—6

—5—3

—11—8

—16—13

16—15—10

—16—11

—12—8

—7—8

—4—7

—7—8

—12—12

—19—17

16—14—10

—16—11

—12—7

—6—8

—4—6

—7—8

—11—11

—17—15

24 — 36 24 — 36—8—6

—9—8

—8—7

—8—9

—8—10

—8—10

—13—14

—16—18

—7—6

—9—8

—8—6

—8—9

—8—10

—8—10

—12—13

—15—16

If it is intended to run this fan in reverse for other than emergency operation, please refer to Fl kt Woods Ltd.

JM AEROFOIL

Page 152: JM Aerofoil 50 Hz Technical

Fan Code: 100JM/31/4/9/...1000 mm 1470 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11802

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 300

200

400

600

800

1000

12000 20000 40000 60000 80000 100000

0 10000 20000 30000 40000 50000 60000

0

20

40

60

80

100

120

0

1

2

3

4

0 5 10 15 20 25 300

5

10

15

20

25

16°

24°

32°

8°16°

24°

32°

102

101

104

106

105

104

110

107

106

101

101

104

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—21—17

—21—18

—14—10

—9—10

—4—6

—6—5

—12—9

—19—15

8—20—17

—20—18

—13—9

—9—10

—4—6

—5—3

—11—8

—16—13

16—15—10

—16—11

—12—8

—7—8

—4—7

—7—8

—12—12

—19—17

16—14—10

—16—11

—12—7

—6—8

—4—6

—7—8

—11—11

—17—15

24 — 36 24 — 36—8—6

—9—8

—8—7

—8—9

—8—10

—8—10

—13—14

—16—18

—7—6

—9—8

—8—6

—8—9

—8—10

—8—10

—12—13

—15—16

If it is intended to run this fan in reverse for other than emergency operation, please refer to Fl kt Woods Ltd.

JM AEROFOIL

Page 153: JM Aerofoil 50 Hz Technical

Fan Code: 100JM/40/4/9/...1000 mm 1470 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11804

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 300

200

400

600

800

1000

1200

14000 20000 40000 60000 80000 100000

0 10000 20000 30000 40000 50000 60000

0

20

40

60

80

100

120

140

0

1

2

3

4

5

0 5 10 15 20 25 3005

101520253035

16°

24°

32°

40°

8° 16°24°

32°

40°

98

100

103

103

105

106

109

110

110

112

113

113

101

102

104

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—9

—10—10—12

—7—7

—5—7

—8—7

—13—9

—19—13

—27—22

8—7—6

—7—9

—6—4

—4—7

—9—7

—13—8

—18—12

—25—21

16—7—6

—11—10

—8—6

—5—7

—8—10

—11—10

—15—12

—23—21

16—3—2

—7—6

—7—5

—6—8

—10—12

—11—11

—15—11

—22—20

24 — 40 24 — 40—5—6

—9—8

—9—8

—5—5

—15—15

—16—17

—17—18

—20—23

—2—3

—5—4

—7—6

—4—4

—14—14

—15—16

—16—17

—19—22

JM AEROFOIL

Page 154: JM Aerofoil 50 Hz Technical

Fan Code: 112JM/40/10/6/...1120 mm 575 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11818

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2 4 6 8 10 12 140

20

40

60

80

100

120

140

160

1800 10000 20000 30000 40000

0 5000 10000 15000 20000 25000

0

5

10

15

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0 2 4 6 8 10 12 140.0

0.5

1.0

1.5

2.0

16°

24°

32°

8°16°

24°

32°

82

83

88

86

86

88

89

88

89

83

85

89

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—10

—7—5—8

—4—6

—8—6

—16—11

—21—16

—28—22

—34—30

8—7—4

—5—7

—5—6

—8—6

—15—10

—21—15

—28—22

—33—29

16—7—5

—6—5

—6—9

—7—10

—12—12

—17—16

—24—22

—29—29

16—5—2

—5—4

—6—9

—7—10

—12—12

—16—15

—24—22

—28—28

24 — 32 24 — 32—6—6

—5—4

—8—9

—8—9

—12—13

—16—17

—20—20

—23—23

—4—3

—4—3

—8—9

—8—9

—12—13

—15—16

—20—20

—22—22

JM AEROFOIL

Page 155: JM Aerofoil 50 Hz Technical

Fan Code: 112JM/40/10/9/...1120 mm 575 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11819

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2 4 6 8 10 12 14 160

50

100

150

200

2500 10000 20000 30000 40000 50000

0 5000 10000 15000 20000 25000 30000

0

5

10

15

20

25

0.0

0.2

0.4

0.6

0.8

1.0

0 2 4 6 8 10 12 14 160.0

0.5

1.0

1.5

2.0

2.5

3.0

16°

24°

32°

8°16°

24°

32°

83

83

88

87

87

87

90

90

90

84

86

88

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—11—10

—5—9

—4—6

—7—4

—15—10

—21—15

—29—23

—35—31

8—8—6

—3—6

—4—6

—6—4

—15—10

—21—15

—28—22

—33—30

16—12

—6—6—8

—4—6

—7—7

—12—9

—19—13

—27—21

—32—27

16—9—3

—3—5

—3—5

—7—6

—14—10

—20—14

—26—20

—32—26

24 — 36 24 — 36—6—5

—7—7

—5—6

—9—10

—13—13

—14—14

—20—21

—25—26

—3—2

—4—4

—4—5

—8—9

—12—12

—14—14

—20—20

—24—25

JM AEROFOIL

Page 156: JM Aerofoil 50 Hz Technical

Fan Code: 112JM/50/10/12/...1120 mm 575 rev/min 12 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11820

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2 4 6 8 10 12 140

50

100

150

200

2500 10000 20000 30000 40000

0 5000 10000 15000 20000 25000

0

5

10

15

20

25

0.0

0.2

0.4

0.6

0.8

1.0

0 2 4 6 8 10 12 140.00.51.01.52.02.53.03.5

16°

24°

32°

8° 16°24°

32°

84

86

88

89

87

88

89

89

89

86

87

90

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—15—14

—5—4

—6—7

—6—6

—11—11

—18—16

—24—21

—33—31

8—12—11

—2—2

—6—6

—7—8

—11—11

—16—14

—21—18

—31—29

16—13—13

—4—2

—7—9

—7—8

—11—12

—17—16

—24—21

—31—29

16—11—10

—11

—7—9

—7—8

—11—12

—16—14

—21—18

—28—27

24 — 36 24 — 36—9—9

—4—3

—8—9

—8—9

—12—12

—15—15

—19—20

—24—25

—6—7

—1—1

—8—9

—8—8

—13—13

—13—13

—16—17

—21—23

JM AEROFOIL

Page 157: JM Aerofoil 50 Hz Technical

Fan Code: 112JM/40/8/6/...1120 mm 720 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11809

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2 4 6 8 10 12 14 16 180

50

100

150

200

250

3000 10000 20000 30000 40000 50000 60000

0 5000 10000 15000 20000 25000 30000 35000

0

5

10

15

20

25

30

0.0

0.2

0.4

0.6

0.8

1.0

1.2

0 2 4 6 8 10 12 14 16 180.00.51.01.52.02.53.03.54.0

16°

24°

32°

8°16°

24°

32°

87

88

93

91

91

93

94

94

94

88

90

94

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—10

—7—7—8

—4—7

—6—6

—13—9

—20—14

—25—19

—32—28

8—8—4

—6—8

—4—7

—6—6

—13—9

—19—14

—26—20

—31—27

16—7—4

—7—6

—6—8

—7—10

—11—12

—15—15

—21—20

—27—27

16—4—2

—6—4

—6—9

—7—10

—10—11

—15—15

—22—20

—26—26

24 — 32 24 — 32—5—5

—6—5

—8—8

—8—9

—11—12

—15—16

—18—19

—22—23

—3—3

—5—4

—8—8

—8—10

—11—12

—15—15

—18—19

—21—22

JM AEROFOIL

Page 158: JM Aerofoil 50 Hz Technical

Fan Code: 112JM/40/8/9/...1120 mm 720 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11810

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 200

50

100

150

200

250

300

3500 10000 20000 30000 40000 50000 60000

0 5000 10000 15000 20000 25000 30000 35000 40000

0

5

10

15

20

25

30

35

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

0 5 10 15 200

1

2

3

4

5

6

16°

24°

32°

8° 16°24°

32°

88

88

93

92

92

92

96

95

96

89

91

94

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—13—16

—7—8

—4—7

—6—4

—12—8

—19—13

—26—20

—33—29

8—11—13

—5—4

—4—7

—5—4

—13—8

—19—13

—25—19

—31—27

16—14—12

—7—6

—4—7

—6—7

—10—8

—16—11

—24—18

—30—25

16—10

—7—5—2

—4—6

—6—6

—12—9

—17—12

—24—17

—30—24

24 — 36 24 — 36—8—7

—6—5

—5—5

—9—10

—12—13

—14—14

—18—18

—24—25

—5—4

—3—1

—3—4

—8—9

—11—12

—13—13

—18—18

—23—24

JM AEROFOIL

Page 159: JM Aerofoil 50 Hz Technical

Fan Code: 112JM/50/8/12/...1120 mm 720 rev/min 12 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11811

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 2 4 6 8 10 12 14 16 180

50

100

150

200

250

300

350

4000 10000 20000 30000 40000 50000 60000

0 5000 10000 15000 20000 25000 30000 35000

0

5

10

15

20

25

30

35

40

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

0 2 4 6 8 10 12 14 16 1801234567

16°

24°

32°

8° 16°24°

32°

90

91

93

94

93

93

95

94

95

91

92

95

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—18—17

—5—4

—8—8

—5—5

—9—10

—16—15

—22—19

—30—28

8—15—14

—2—2

—8—7

—6—7

—9—10

—14—13

—19—16

—28—26

16—15—14

—4—2

—8—10

—6—8

—10—11

—16—14

—22—19

—29—27

16—13—12

—11

—7—9

—6—8

—10—11

—14—13

—19—16

—27—25

24 — 36 24 — 36—9

—10—4—3

—8—9

—8—9

—11—11

—14—15

—18—19

—22—24

—7—7

—2—1

—7—8

—8—9

—12—12

—12—12

—15—16

—20—22

JM AEROFOIL

Page 160: JM Aerofoil 50 Hz Technical

Fan Code: 112JM/40/6/6/...1120 mm 960 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11812

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 250

100

200

300

400

5000 20000 40000 60000 80000

0 10000 20000 30000 40000 50000

0

10

20

30

40

50

0.0

0.5

1.0

1.5

2.0

0 5 10 15 20 250123456789

16°

24°

32°

8°16°

24°

32°

95

96

100

98

99

101

102

101

102

94

97

100

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—10

—9—10—10

—5—10

—6—7

—11—9

—19—14

—23—19

—31—27

8—8—5

—7—6

—5—9

—5—6

—10—8

—18—12

—23—18

—29—25

16—6—4

—10—7

—8—9

—8—13

—11—13

—16—16

—21—20

—28—27

16—2—1

—8—5

—8—9

—7—12

—10—12

—15—16

—20—20

—26—26

24 — 32 24 — 32—4—4

—9—7

—8—7

—10—11

—12—12

—15—16

—19—20

—23—24

—2—2

—7—6

—9—8

—9—11

—12—12

—14—15

—18—20

—22—22

JM AEROFOIL

Page 161: JM Aerofoil 50 Hz Technical

Fan Code: 112JM/40/6/9/...1120 mm 960 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11813

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 250

100

200

300

400

500

600

7000 20000 40000 60000 80000

0 10000 20000 30000 40000 50000

0

10

20

30

40

50

60

70

0.0

0.5

1.0

1.5

2.0

2.5

0 5 10 15 20 2502468

101214

16°

24°

32°

8°16°

24°

32°

95

94

100

98

99

99

102

102

103

96

97

100

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—15—15

—11—9

—6—9

—5—6

—10—7

—18—12

—24—18

—31—27

8—12—10

—7—6

—4—8

—4—5

—10—6

—17—11

—22—16

—29—24

16—14—12

—13—7

—5—7

—5—8

—9—9

—14—11

—21—16

—29—24

16—10

—7—10

—4—4—5

—5—7

—9—9

—15—11

—20—14

—28—22

24 — 36 24 — 36—8—8

—8—6

—5—5

—11—11

—12—13

—15—15

—17—17

—24—25

—4—4

—5—3

—3—3

—9—10

—11—11

—14—14

—16—16

—22—23

JM AEROFOIL

Page 162: JM Aerofoil 50 Hz Technical

Fan Code: 112JM/50/6/12/...1120 mm 960 rev/min 12 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11814

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 250

100

200

300

400

500

600

7000 20000 40000 60000 80000

0 10000 20000 30000 40000 50000

0

10

20

30

40

50

60

70

0.0

0.5

1.0

1.5

2.0

2.5

0 5 10 15 20 2502468

10121416

16°

24°

32°

8° 16°24°

32°

96

97

99

100

99

99

101

101

101

97

98

102

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—18—17

—10—10

—6—5

—5—5

—8—7

—14—13

—19—17

—27—24

8—14—13

—8—8

—4—3

—6—7

—7—7

—12—11

—16—14

—24—22

16—13—12

—9—8

—5—4

—7—8

—8—9

—14—13

—20—17

—27—24

16—10

—9—7—7

—3—1

—6—8

—8—9

—12—11

—16—14

—24—21

24 — 36 24 — 36—7—8

—8—7

—6—5

—8—9

—10—10

—14—14

—16—17

—21—22

—5—6

—6—5

—4—3

—8—9

—10—10

—12—12

—13—14

—19—20

JM AEROFOIL

Page 163: JM Aerofoil 50 Hz Technical

Fan Code: 112JM/40/4/6/...1120 mm 1470 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11815

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 30 350

200

400

600

800

1000

12000 20000 40000 60000 80000 100000 120000

0 10000 20000 30000 40000 50000 60000 70000

0

20

40

60

80

100

120

0

1

2

3

4

0 5 10 15 20 25 30 3505

101520253035

16°

24°

32°

8°16°

24°

32°

108

108

111

109

110

112

112

112

114

104

107

110

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—8—6

—11—8

—8—10

—5—8

—7—7

—13—10

—21—15

—26—20

8—6—5

—9—6

—8—9

—5—8

—7—7

—13—10

—21—16

—25—19

16—3—2

—10—9

—10—9

—9—12

—9—14

—13—16

—18—19

—24—23

16—1

0—8—7

—10—9

—9—12

—9—13

—13—15

—19—19

—23—22

24 — 32 24 — 32—3—3

—9—9

—9—8

—11—11

—11—13

—14—15

—18—19

—21—22

—1—1

—7—7

—8—7

—11—11

—11—13

—13—14

—18—19

—20—21

If it is intended to run this fan in reverse for other than emergency operation, please refer to Fl kt Woods Ltd.

JM AEROFOIL

Page 164: JM Aerofoil 50 Hz Technical

Fan Code: 112JM/40/4/9/...1120 mm 1470 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11816

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 30 35 400

200

400

600

800

1000

1200

1400

16000 20000 40000 60000 80000 100000 120000

0 10000 20000 30000 40000 50000 60000 70000 80000

0

20

40

60

80

100

120

140

160

0

1

2

3

4

5

6

0 5 10 15 20 25 30 35 400

10

20

30

40

50

16°

24°

32°

8°16°

24°

32°

104

103

109

108

108

108

112

112

113

105

106

109

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—15—13

—14—17

—7—8

—4—8

—6—4

—12—8

—19—13

—26—20

8—12

—9—11—14

—6—6

—4—7

—6—5

—12—8

—18—12

—25—18

16—15—12

—14—12

—7—6

—4—7

—6—7

—10—9

—16—11

—24—18

16—11—7

—11—9

—6—4

—5—7

—7—8

—11—9

—16—10

—24—17

24 — 36 24 — 36—7—7

—9—8

—8—6

—6—6

—10—11

—13—14

—15—15

—19—19

—4—4

—6—5

—6—4

—5—5

—10—10

—13—13

—14—14

—18—18

If it is intended to run this fan in reverse for other than emergency operation, please refer to Fl kt Woods Ltd.

JM AEROFOIL

Page 165: JM Aerofoil 50 Hz Technical

Fan Code: 112JM/50/4/12/...1120 mm 1470 rev/min 12 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11817

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 30 35 400

200

400

600

800

1000

1200

1400

16000 20000 40000 60000 80000 100000 120000

0 10000 20000 30000 40000 50000 60000 70000 80000

0

20

40

60

80

100

120

140

160

0

1

2

3

4

5

6

0 5 10 15 20 25 30 35 400

10

20

30

40

50

60

8∫

16∫

24∫

32∫

8∫ 16∫24∫

32∫

105

106

109

110

109

109

111

111

111

106

107

111

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—17—16

—18—17

—5—5

—8—8

—5—5

—9—10

—16—15

—21—19

8—13—13

—17—16

—3—3

—8—8

—4—5

—7—7

—13—12

—19—17

16—11—11

—15—14

—5—3

—8—10

—6—8

—10—11

—16—14

—22—19

16—8—8

—13—12

—3—1

—7—9

—6—8

—8—9

—13—12

—19—17

24 — 36 24 — 36—6—7

—10—10

—5—4

—9—10

—9—10

—12—12

—15—15

—19—19

—4—5

—8—8

—4—3

—8—9

—9—10

—10—10

—12—12

—16—17

If it is intended to run this fan in reverse for other than emergency operation, please refer to Fl kt Woods Ltd.

JM AEROFOIL

Page 166: JM Aerofoil 50 Hz Technical

Fan Code: 125JM/40/10/6/...1250 mm 575 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11836

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 200

50

100

150

2000 10000 20000 30000 40000 50000 60000

0 5000 10000 15000 20000 25000 30000 35000 40000

0

5

10

15

20

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0 5 10 15 200.0

0.5

1.0

1.5

2.0

2.5

3.0

86

86

95

89

16°

24°

32°

8°16°

24°

32°

88

93

93

92

92

88

91

93

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—11—14

—4—10

—4—4

—9—5

—17—11

—23—16

—27—21

—32—31

8—8

—11—4—9

—4—4

—9—5

—17—11

—22—16

—28—21

—31—30

16—11—6

—8—5

—4—8

—6—8

—11—11

—17—14

—23—19

—28—26

16—8—4

—7—4

—4—9

—6—8

—11—11

—17—14

—24—19

—27—25

24 — 32 24 — 32—8—6

—6—4

—6—9

—6—9

—13—13

—17—15

—20—18

—22—22

—6—3

—5—3

—6—9

—6—9

—13—13

—16—15

—20—18

—21—21

JM AEROFOIL

Page 167: JM Aerofoil 50 Hz Technical

Fan Code: 125JM/40/10/9/...1250 mm 575 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11837

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 250

50

100

150

200

250

3000 20000 40000 60000 80000

0 10000 20000 30000 40000 50000

0

5

10

15

20

25

30

0.0

0.2

0.4

0.6

0.8

1.0

1.2

0 5 10 15 20 250

1

2

3

4

5

16°

24°

32°

8°16°

24°

32°

91

87

96

92

91

90

94

93

95

90

93

94

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—14—14

—6—10

—3—5

—7—4

—15—11

—23—16

—29—21

—36—32

8—11—11

—4—8

—3—5

—6—3

—15—11

—23—16

—28—20

—34—30

16—15

—8—7—9

—4—6

—6—5

—14—9

—22—14

—29—19

—34—27

16—12

—5—4—7

—3—5

—6—5

—15—10

—22—14

—28—18

—34—26

24 — 36 24 — 36—7—6

—7—7

—6—7

—7—7

—12—12

—15—13

—22—18

—25—24

—4—2

—4—4

—5—6

—6—6

—12—11

—14—12

—21—18

—24—23

JM AEROFOIL

Page 168: JM Aerofoil 50 Hz Technical

Fan Code: 125JM/50/10/12/...1250 mm 575 rev/min 12 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11840

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 250

50

100

150

200

250

3000 20000 40000 60000 80000

0 10000 20000 30000 40000 50000

0

5

10

15

20

25

30

0.0

0.2

0.4

0.6

0.8

1.0

1.2

0 5 10 15 20 250

1

2

3

4

5

6

16°

24°

32°

8° 16°24°

32°

86

88

93

91

89

90

92

92

92

89

91

98

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—15—14

—6—4

—5—7

—6—6

—11—11

—19—17

—25—22

—35—31

8—13—11

—3—1

—5—6

—7—8

—11—11

—16—14

—23—19

—32—29

16—14—13

—5—3

—6—9

—5—8

—11—12

—19—16

—25—21

—33—29

16—11—10

—31

—5—9

—5—8

—11—12

—17—15

—22—18

—30—27

24 — 36 24 — 36—9—9

—4—4

—7—8

—7—8

—12—12

—15—15

—19—19

—23—24

—7—6

—2—1

—7—8

—7—8

—12—12

—13—13

—16—17

—21—22

JM AEROFOIL

Page 169: JM Aerofoil 50 Hz Technical

Fan Code: 125JM/40/8/6/...1250 mm 720 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11821

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 250

50

100

150

200

250

300

3500 20000 40000 60000 80000

0 10000 20000 30000 40000 50000

0

5

10

15

20

25

30

35

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

0 5 10 15 20 250

1

2

3

4

5

6

16°

24°

32°

8°16°

24°

32°

91

91

99

94

93

98

98

97

98

93

96

98

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—15—14

—6—11

—3—5

—7—4

—15—9

—21—15

—26—19

—31—28

8—12—12

—5—10

—4—5

—7—4

—14—8

—21—15

—26—19

—30—27

16—11—7

—9—5

—6—8

—4—8

—9—10

—15—13

—22—16

—26—24

16—9—5

—8—3

—5—8

—4—8

—9—10

—15—13

—22—17

—25—23

24 — 32 24 — 32—9—6

—7—4

—7—8

—5—9

—12—12

—16—15

—19—17

—21—21

—6—4

—5—3

—7—9

—5—9

—12—12

—15—14

—19—17

—20—20

JM AEROFOIL

Page 170: JM Aerofoil 50 Hz Technical

Fan Code: 125JM/40/8/6/...1250 mm 720 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11821

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 250

50

100

150

200

250

300

3500 20000 40000 60000 80000

0 10000 20000 30000 40000 50000

0

5

10

15

20

25

30

35

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

0 5 10 15 20 250

1

2

3

4

5

6

16°

24°

32°

8°16°

24°

32°

91

91

99

94

93

98

98

97

98

93

96

98

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—15—14

—6—11

—3—5

—7—4

—15—9

—21—15

—26—19

—31—28

8—12—12

—5—10

—4—5

—7—4

—14—8

—21—15

—26—19

—30—27

16—11—7

—9—5

—6—8

—4—8

—9—10

—15—13

—22—16

—26—24

16—9—5

—8—3

—5—8

—4—8

—9—10

—15—13

—22—17

—25—23

24 — 32 24 — 32—9—6

—7—4

—7—8

—5—9

—12—12

—16—15

—19—17

—21—21

—6—4

—5—3

—7—9

—5—9

—12—12

—15—14

—19—17

—20—20

JM AEROFOIL

Page 171: JM Aerofoil 50 Hz Technical

Fan Code: 125JM/40/8/9/...1250 mm 720 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11822

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 300

50

100

150

200

250

300

350

400

4500 20000 40000 60000 80000 100000

0 10000 20000 30000 40000 50000 60000

0

10

20

30

40

0.0

0.5

1.0

1.5

0 5 10 15 20 25 300

2

4

6

8

10

16°

24°

32°

8°16°

24°

32°

96

92

101

97

96

95

100

98

100

95

98

99

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—18—23

—8—10

—5—9

—4—2

—12—9

—20—15

—27—19

—34—29

8—16—19

—6—7

—5—9

—3—2

—13—9

—20—15

—26—18

—32—28

16—19—15

—8—7

—5—8

—4—4

—11—8

—19—12

—27—17

—32—25

16—14—11

—5—3

—4—7

—5—4

—13—9

—20—13

—26—16

—32—23

24 — 36 24 — 36—9—8

—6—5

—6—7

—7—7

—12—11

—14—13

—20—16

—24—23

—6—5

—3—2

—5—6

—5—6

—11—10

—13—12

—19—15

—23—22

JM AEROFOIL

Page 172: JM Aerofoil 50 Hz Technical

Fan Code: 125JM/50/8/12/...1250 mm 720 rev/min 12 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11825

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 300

50

100

150

200

250

300

350

400

4500 20000 40000 60000 80000 100000

0 10000 20000 30000 40000 50000 60000

0

10

20

30

40

0.0

0.5

1.0

1.5

0 5 10 15 20 25 300

2

4

6

8

10

12

16°

24°

32°

8° 16°24°

32°

91

93

98

97

94

95

98

98

98

94

96

103

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—19—17

—6—4

—8—8

—4—5

—9—10

—17—15

—23—20

—32—29

8—16—14

—4—2

—7—7

—5—7

—8—10

—14—13

—20—17

—30—27

16—16—14

—7—3

—6—10

—5—8

—8—11

—16—15

—23—20

—30—27

16—14—11

—41

—6—9

—5—8

—8—11

—15—13

—20—17

—28—25

—9—9

—5—4

—7—9

—7—8

—11—11

—14—14

—18—18

—22—23

—7—7

—3—2

—7—8

—7—8

—11—11

—12—12

—15—15

—20—21

24 — 36 24 — 36

JM AEROFOIL

Page 173: JM Aerofoil 50 Hz Technical

Fan Code: 125JM/40/6/6/...1250 mm 960 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11826

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 30 350

100

200

300

400

500

6000 20000 40000 60000 80000 100000 120000

0 10000 20000 30000 40000 50000 60000 70000

0

10

20

30

40

50

60

0.0

0.5

1.0

1.5

2.0

0 5 10 15 20 25 30 3502468

101214

16°

24°

32°

8°16°

24°

32°

99

98

106

103

102

105

105

104

105

100

102

104

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—14—12

—8—13

—5—10

—6—3

—12—7

—20—14

—24—18

—29—25

8—11—10

—6—10

—4—10

—5—3

—11—6

—19—13

—24—18

—28—24

16—9—5

—10—6

—8—8

—5—10

—8—11

—14—14

—20—16

—26—23

16—7—3

—8—5

—8—8

—4—10

—7—10

—13—13

—20—17

—24—22

24 — 32 24 — 32—7—5

—8—6

—8—8

—5—10

—10—12

—15—16

—18—18

—22—21

—5—3

—6—4

—9—9

—5—10

—10—12

—15—15

—18—18

—21—20

JM AEROFOIL

Page 174: JM Aerofoil 50 Hz Technical

Fan Code: 125JM/40/6/9/...1250 mm 960 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11827

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 30 350

100

200

300

400

500

600

700

8000 20000 40000 60000 80000 100000 120000

0 10000 20000 30000 40000 50000 60000 70000

0

10

20

30

40

50

60

70

80

0.0

0.5

1.0

1.5

2.0

2.5

3.0

0 5 10 15 20 25 30 350

5

10

15

20

25

16°

24°

32°

8°16°

24°

32°

102

99

108

104

103

102

106

105

108

101

104

106

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—22—20

—13—13

—6—10

—3—3

—9—6

—17—13

—25—17

—31—25

8—20—15

—9—10

—5—10

—2—3

—9—6

—17—12

—23—16

—30—23

16—20—17

—15—7

—6—8

—4—6

—8—7

—16—11

—24—15

—30—22

16—16—12

—12—5

—4—7

—4—5

—9—8

—17—11

—23—14

—29—21

24 — 36 24 — 36—8—8

—7—6

—6—7

—7—8

—9—9

—13—13

—17—15

—24—21

—5—4

—4—3

—5—5

—6—7

—8—9

—13—12

—17—14

—23—20

JM AEROFOIL

Page 175: JM Aerofoil 50 Hz Technical

Fan Code: 125JM/50/6/12/...1250 mm 960 rev/min 12 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11830

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 30 350

100

200

300

400

500

600

700

8000 20000 40000 60000 80000 100000 120000

0 10000 20000 30000 40000 50000 60000 70000

0

10

20

30

40

50

60

70

80

0.0

0.5

1.0

1.5

2.0

2.5

3.0

0 5 10 15 20 25 30 350

5

10

15

20

25

30

16°

24°

32°

8° 16°24°

32°

98

100

104

103

101

102

104

104

104

100

102

109

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—20—17

—11—9

—7—5

—4—6

—7—8

—14—14

—20—18

—28—24

8—15—13

—9—8

—5—3

—6—7

—7—7

—12—11

—17—15

—26—22

16—14—12

—10—8

—6—4

—5—8

—6—9

—14—13

—21—18

—28—24

16—11—9

—9—6

—4—1

—5—8

—6—9

—12—11

—17—14

—25—22

24 — 36 24 — 36—7—7

—9—8

—6—5

—7—8

—9—10

—14—13

—16—16

—21—22

—5—5

—7—6

—4—3

—7—8

—10—10

—12—11

—13—13

—19—19

JM AEROFOIL

Page 176: JM Aerofoil 50 Hz Technical

Fan Code: 125JM/40/4/6/...1250 mm 1470 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11831

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 500

200

400

600

800

1000

1200

14000 50000 100000 150000

0 20000 40000 60000 80000 100000

0

20

40

60

80

100

120

140

0

1

2

3

4

5

0 10 20 30 40 500

10

20

30

40

50

16°

24°

32°

8°16°

24°

32°

110

109

116

114

113

115

115

115

116

109

112

114

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—11—9

—15—15

—6—11

—4—5

—7—5

—15—9

—21—16

—26—19

8—10

—8—13—13

—5—11

—4—5

—7—5

—14—9

—22—16

—25—18

16—6—3

—12—10

—10—8

—7—11

—5—11

—10—13

—16—16

—22—19

16—4—1

—11—8

—9—7

—7—11

—5—11

—10—13

—17—17

—21—18

24 — 32 24 — 32—5—3

—10—9

—8—7

—9—11

—6—12

—13—14

—17—18

—20—20

—3—1

—9—7

—7—6

—9—11

—6—12

—13—14

—17—18

—19—19

If it is intended to run this fan in reverse for other than emergency operation, please refer to Fl kt Woods Ltd.

JM AEROFOIL

Page 177: JM Aerofoil 50 Hz Technical

Fan Code: 125JM/40/4/9/...1250 mm 1470 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11832

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 50 600

200

400

600

800

1000

1200

1400

1600

18000 50000 100000 150000 200000

0 20000 40000 60000 80000 100000 120000

0

50

100

150

0

1

2

3

4

5

6

7

0 10 20 30 40 50 600

1020304050607080

16°

24°

32°

8°16°

24°

32°

111

108

117

113

112

112

116

114

117

111

113

115

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—22—17

—18—23

—8—10

—5—9

—4—2

—12—9

—20—15

—27—19

8—20—14

—16—20

—7—9

—4—9

—4—3

—12—9

—19—14

—25—17

16—24—18

—19—16

—8—7

—5—8

—4—5

—11—8

—19—12

—27—16

16—20—14

—16—13

—6—5

—6—8

—6—6

—12—9

—18—11

—26—15

24 — 36 24 — 36—9—8

—9—9

—7—6

—7—8

—7—8

—12—12

—14—13

—20—16

—6—5

—6—6

—5—4

—6—6

—7—7

—12—11

—14—12

—19—15

If it is intended to run this fan in reverse for other than emergency operation, please refer to Fl kt Woods Ltd.

JM AEROFOIL

Page 178: JM Aerofoil 50 Hz Technical

Fan Code: 125JM/50/4/6/...1250 mm 1470 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11833

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 30 35 40 450

200

400

600

800

1000

1200

14000 20000 40000 60000 80000 100000 120000 140000

0 20000 40000 60000 80000

0

20

40

60

80

100

120

140

0

1

2

3

4

5

0 5 10 15 20 25 30 35 40 450

10

20

30

40

50

16°

24°

32°

8°16°

24°

32°

107

108

116

108

110

111

113

113

113

106

112

113

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—18—14

—11—8

—10—8

—11—8

—2—5

—10—9

—19—13

—24—15

8—16—12

—9—6

—9—8

—11—8

—1—4

—10—9

—18—12

—23—13

16—17—10

—10—5

—8—5

—6—10

—4—11

—12—12

—17—16

—23—19

16—15

—8—8—4

—8—5

—6—9

—5—12

—12—12

—17—16

—23—19

24 — 32 24 — 32—7—6

—6—7

—7—7

—9—9

—9—10

—13—13

—15—15

—17—17

—4—3

—5—5

—7—7

—8—9

—10—11

—12—12

—13—14

—17—17

If it is intended to run this fan in reverse for other than emergency operation, please refer to Fl kt Woods Ltd.

JM AEROFOIL

Page 179: JM Aerofoil 50 Hz Technical

Fan Code: 125JM/50/4/9/...1250 mm 1470 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11834

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 50 600

200

400

600

800

1000

1200

1400

16000 50000 100000 150000 200000

0 20000 40000 60000 80000 100000 120000

0

20

40

60

80

100

120

140

160

0

1

2

3

4

5

6

0 10 20 30 40 50 600

1020304050607080

16°

24°

32°

8°16°

24°

32°

109

110

117

114

114

114

118

118

119

108

110

120

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—20—15

—14—10

—10—6

—6—10

—3—6

—10—9

—16—12

—23—15

8—18—12

—13—9

—9—4

—6—9

—3—5

—8—8

—15—12

—22—14

16—17—13

—12—9

—6—3

—4—10

—6—9

—12—12

—18—14

—25—17

16—14—10

—11—8

—4—1

—4—9

—6—9

—12—11

—17—13

—24—16

24 — 36 24 — 36—8

—10—9—8

—6—3

—9—10

—9—11

—13—13

—17—17

—20—20

—4—6

—7—7

—4—1

—8—8

—9—10

—12—12

—16—15

—19—19

If it is intended to run this fan in reverse for other than emergency operation, please refer to Fl kt Woods Ltd.

JM AEROFOIL

Page 180: JM Aerofoil 50 Hz Technical

Fan Code: 125JM/50/4/12/...1250 mm 1470 rev/min 12 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11835

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 50 600

500

1000

1500

20000 50000 100000 150000 200000

0 20000 40000 60000 80000 100000 120000

0

50

100

150

200

0

1

2

3

4

5

6

7

8

0 10 20 30 40 50 600

102030405060708090

16°

24°

32°

8° 16°24°

32°

107

109

113

112

111

112

114

114

114

110

112

118

ISO 5801

Type DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—18—16

—19—17

—7—4

—8—8

—4—5

—8—10

—16—15

—23—19

8—15—13

—18—16

—5—3

—8—8

—4—5

—6—8

—13—12

—20—17

16—12—10

—16—14

—7—3

—6—10

—5—8

—8—11

—16—15

—23—20

16—9—8

—15—12

—5—1

—6—9

—5—8

—7—9

—13—12

—21—17

24 — 36 24 — 36—6—7

—10—10

—7—5

—8—9

—8—9

—12—11

—15—15

—19—18

—4—5

—8—8

—5—3

—8—9

—9—10

—10—9

—12—12

—16—16

If it is intended to run this fan in reverse for other than emergency operation, please refer to Fl kt Woods Ltd.

JM AEROFOIL

Page 181: JM Aerofoil 50 Hz Technical

Fan Code: 140JM/40/12/6/...1400 mm 480 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11852

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 250

20

40

60

80

100

120

140

160

1800 20000 40000 60000 80000

0 10000 20000 30000 40000 50000

0

5

10

15

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0 5 10 15 20 250.00.51.01.52.02.53.03.5

16°

24°

32°

8°16°

24°

32°

86

85

88

88

87

89

93

91

90

88

88

93

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—13—10

—11—12

—3—8

—6—5

—11—7

—13—8

—26—23

—32—30

8—11—8

—9—10

—3—7

—5—5

—10—7

—11—7

—25—22

—30—29

16—10

—5—10

—8—3—8

—7—11

—13—9

—17—8

—22—20

—26—24

16—9—3

—9—6

—2—8

—7—11

—12—8

—17—8

—20—19

—25—23

24 — 36 24 — 36—5—5

—8—7

—7—7

—8—10

—13—13

—15—14

—17—16

—19—18

—3—3

—7—6

—6—5

—7—8

—12—13

—14—13

—15—14

—17—16

JM AEROFOIL

Page 182: JM Aerofoil 50 Hz Technical

Fan Code: 140JM/40/12/9/...1400 mm 480 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11853

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 250

50

100

150

200

2500 20000 40000 60000 80000

0 10000 20000 30000 40000 50000

0

5

10

15

20

25

0.0

0.2

0.4

0.6

0.8

1.0

0 5 10 15 20 250.00.51.01.52.02.53.03.54.04.5

16°

24°

32°

8°16°

24°

32°

87

84

85

86

85

86

89

88

87

88

90

91

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—14—13

—11—13

—4—8

—5—6

—10—5

—14—7

—25—22

—31—28

8—11—10

—9—11

—3—8

—3—5

—9—4

—12—5

—25—21

—30—27

16—8—9

—10—11

—6—9

—7—8

—9—5

—10—7

—17—19

—20—24

16—5—5

—8—9

—5—8

—7—8

—7—4

—10—6

—15—19

—19—22

24 — 36 24 — 36—5—5

—9—8

—7—7

—8—8

—11—10

—14—14

—14—17

—15—19

—1—1

—6—5

—5—4

—7—7

—11—9

—13—13

—13—15

—14—17

JM AEROFOIL

Page 183: JM Aerofoil 50 Hz Technical

Fan Code: 140JM/40/10/6/...1400 mm 575 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11854

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 300

50

100

150

200

2500 20000 40000 60000 80000 100000

0 10000 20000 30000 40000 50000 60000

0

5

10

15

20

25

0.0

0.2

0.4

0.6

0.8

1.0

0 5 10 15 20 25 300

1

2

3

4

5

6

16°

24°

32°

8°16°

24°

32°

90

89

92

92

92

92

96

95

94

92

92

97

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—17—15

—12—10

—5—9

—4—5

—9—7

—11—7

—22—19

—29—28

8—14—12

—10—8

—4—8

—4—4

—9—6

—10—5

—22—18

—28—27

16—13

—8—10

—6—4—8

—4—10

—11—9

—16—8

—21—17

—24—23

16—11—5

—9—4

—4—7

—4—10

—11—9

—16—7

—19—16

—23—22

24 — 36—8—7

—5—5

—7—7

—8—8

—12—12

—15—14

—16—16

—18—17

—6—4

—4—4

—6—5

—6—7

—11—12

—13—13

—15—14

—16—16

24 — 36 24 — 3624 — 36

JM AEROFOIL

Page 184: JM Aerofoil 50 Hz Technical

Fan Code: 140JM/40/10/9/...1400 mm 575 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11855

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 300

50

100

150

200

250

300

3500 20000 40000 60000 80000 100000

0 10000 20000 30000 40000 50000 60000

0

5

10

15

20

25

30

35

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

0 5 10 15 20 25 30012345678

16°

24°

32°

8°16°

24°

32°

91

88

89

90

89

89

93

92

91

92

94

94

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—15—14

—12—15

—6—9

—4—6

—9—6

—12—5

—23—18

—28—26

8—12—11

—10—12

—5—9

—2—5

—8—5

—11—3

—24—18

—28—25

16—8—9

—12—13

—6—9

—6—8

—9—7

—9—5

—16—17

—19—22

16—5—6

—10—10

—6—7

—6—8

—7—5

—8—5

—14—17

—18—20

24 — 36 24 — 36—6—6

—10—9

—7—6

—7—8

—10—10

—14—13

—14—16

—14—17

—1—1

—7—6

—5—4

—7—7

—9—8

—13—12

—13—14

—13—16

JM AEROFOIL

Page 185: JM Aerofoil 50 Hz Technical

Fan Code: 140JM/50/10/12/...1400 mm 575 rev/min 12 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11857

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 300

50

100

150

200

250

300

3500 20000 40000 60000 80000 100000

0 10000 20000 30000 40000 50000 60000

0

5

10

15

20

25

30

35

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

0 5 10 15 20 25 300123456789

16°

24°

32°

8°16°

24°

32°

91

89

92

91

90

90

92

92

92

93

95

96

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—13—15

—8—12

—5—8

—5—4

—11—7

—16—8

—27—20

—32—26

8—11—13

—5—10

—5—8

—4—4

—10—6

—14—6

—25—18

—30—24

16—16—12

—10—6

—3—9

—5—7

—12—8

—19—8

—26—18

—29—22

16—12

—8—7—3

—2—9

—5—8

—11—7

—19—6

—24—15

—28—19

24 — 36—7—8

—6—5

—8—8

—7—8

—11—10

—15—12

—16—18

—16—20

—4—4

—20

—7—6

—6—7

—10—9

—14—12

—14—17

—15—19

24 — 36

JM AEROFOIL

Page 186: JM Aerofoil 50 Hz Technical

Fan Code: 140JM/40/8/6/...1400 mm 720 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11841

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 30 350

50

100

150

200

250

300

350

4000 20000 40000 60000 80000 100000 120000

0 10000 20000 30000 40000 50000 60000 70000

0

5

10

15

20

25

30

35

40

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

0 5 10 15 20 25 30 350

2

4

6

8

10

12

16°

24°

32°

8°16°

24°

32°

95

94

97

97

97

98

102

100

99

97

97

102

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—19—17

—13—11

—8—11

—3—6

—8—6

—11—6

—17—13

—27—25

8—15—13

—11—9

—7—10

—3—5

—7—6

—9—5

—16—11

—26—24

16—15

—9—10

—6—7—8

—3—9

—9—10

—14—8

—20—13

—23—21

16—12

—6—8—4

—7—8

—3—9

—9—10

—14—7

—18—12

—22—21

24 — 36 24 — 36—9—7

—5—5

—7—7

—7—8

—11—12

—14—14

—16—15

—17—17

—6—4

—4—4

—7—6

—6—6

—10—12

—13—13

—14—13

—16—16

JM AEROFOIL

Page 187: JM Aerofoil 50 Hz Technical

Fan Code: 140JM/40/8/9/...1400 mm 720 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11842

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 30 35 400

100

200

300

400

5000 20000 40000 60000 80000 100000 120000

0 10000 20000 30000 40000 50000 60000 70000 80000

0

10

20

30

40

50

0.0

0.5

1.0

1.5

2.0

0 5 10 15 20 25 30 35 4002468

10121416

16°

24°

32°

8°16°

24°

32°

96

93

94

95

94

95

98

97

96

97

98

99

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—17—18

—13—13

—8—11

—3—7

—7—7

—11—4

—19—12

—27—24

8—14—15

—11—10

—8—11

—2—5

—6—5

—10—3

—19—12

—26—23

16—8

—12—10—10

—9—10

—6—8

—8—8

—9—5

—14—12

—18—20

16—4—8

—8—7

—8—8

—6—8

—7—7

—8—4

—12—12

—17—18

24 — 36 24 — 36—7—7

—7—7

—8—7

—7—7

—9—9

—13—12

—15—15

—14—17

—3—3

—3—3

—6—5

—7—6

—9—8

—12—11

—13—13

—13—16

JM AEROFOIL

Page 188: JM Aerofoil 50 Hz Technical

Fan Code: 140JM/50/8/12/...1400 mm 720 rev/min 12 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11844

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 30 35 400

100

200

300

400

500

6000 20000 40000 60000 80000 100000 120000

0 10000 20000 30000 40000 50000 60000 70000 80000

0

10

20

30

40

50

60

0.0

0.5

1.0

1.5

2.0

0 5 10 15 20 25 30 35 4002468

1012141618

16°

24°

32°

8°16°

24°

32°

96

94

97

96

96

96

98

98

98

98

100

101

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—16—18

—8—12

—8—10

—4—5

—8—6

—14—7

—23—14

—30—24

8—14—15

—5—9

—8—10

—3—4

—7—5

—12—5

—21—12

—28—22

16—16—11

—12—5

—5—11

—4—8

—9—8

—17—7

—25—14

—28—21

16—13

—8—9—2

—4—10

—4—8

—9—8

—16—6

—22—11

—26—18

24 — 36—6—7

—6—5

—10—9

—8—8

—10—10

—14—12

—17—17

—16—20

—3—3

—2—1

—8—7

—7—7

—9—9

—14—11

—15—16

—15—19

24 — 36

JM AEROFOIL

Page 189: JM Aerofoil 50 Hz Technical

Fan Code: 140JM/40/6/6/...1400 mm 960 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11845

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 30 35 40 450

100

200

300

400

500

600

7000 20000 40000 60000 80000 100000 120000 140000

0 20000 40000 60000 80000

0

10

20

30

40

50

60

70

0.0

0.5

1.0

1.5

2.0

2.5

0 5 10 15 20 25 30 35 40 450

5

10

15

20

25

16°

24°

32°

8°16°

24°

32°

103

101

104

104

105

106

110

108

106

104

103

108

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—15—12

—14—11

—12—12

—4—8

—6—6

—11—7

—13—8

—26—23

8—12

—9—11—9

—11—11

—3—7

—5—5

—9—6

—12—7

—24—22

16—12

—6—10

—7—11—9

—4—10

—7—12

—13—10

—18—10

—23—22

16—10

—2—9—5

—10—9

—3—10

—7—12

—13—10

—16—9

—21—21

24 — 36 24 — 36—7—5

—5—7

—9—9

—8—8

—10—11

—14—14

—16—16

—18—18

—4—1

—4—5

—8—7

—7—7

—9—11

—12—13

—14—14

—16—17

If it is intended to run this fan in reverse for other than emergency operation, please refer to Fl kt Woods Ltd.

JM AEROFOIL

Page 190: JM Aerofoil 50 Hz Technical

Fan Code: 140JM/40/6/9/...1400 mm 960 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11846

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 500

100

200

300

400

500

600

700

800

9000 50000 100000 150000

0 20000 40000 60000 80000 100000

0

20

40

60

80

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

0 10 20 30 40 5005

101520253035

16°

24°

32°

8°16°

24°

32°

102

100

101

102

101

102

105

104

103

103

105

106

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—19—18

—15—13

—12—14

—4—9

—5—7

—11—6

—14—7

—26—22

8—15—15

—12—10

—10—13

—2—7

—4—5

—9—4

—14—6

—25—20

16—7

—12—9—9

—11—11

—7—10

—8—9

—10—6

—11—7

—18—20

16—4—8

—6—6

—10—10

—7—9

—7—8

—9—5

—9—7

—17—17

24 — 36 24 — 36—6—7

—6—6

—10—9

—8—8

—9—9

—12—11

—15—14

—15—18

—2—3

—3—3

—8—6

—7—7

—8—8

—11—11

—14—12

—14—16

If it is intended to run this fan in reverse for other than emergency operation, please refer to Fl kt Woods Ltd.

JM AEROFOIL

Page 191: JM Aerofoil 50 Hz Technical

Fan Code: 140JM/50/6/9/...1400 mm 960 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11847

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 500

100

200

300

400

500

600

700

800

9000 50000 100000 150000

0 20000 40000 60000 80000 100000

0

20

40

60

80

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

0 10 20 30 40 5005

101520253035

16°

24°

32°

8°16°

24°

32°

104

103

107

106

106

107

109

109

109

105

106

110

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—15—12

—10—11

—9—11

—4—6

—6—6

—12—8

—15—11

—27—24

8—12

—9—8—8

—8—10

—3—5

—5—5

—11—7

—15—9

—25—22

16—12

—7—12

—8—9—8

—3—9

—8—9

—13—9

—18—11

—24—20

16—9—5

—9—5

—7—6

—3—7

—6—8

—12—7

—16—10

—23—19

24 — 36 24 — 36—6—5

—5—5

—9—9

—9—10

—11—13

—14—14

—16—16

—18—19

—4—3

—2—2

—8—7

—7—8

—10—11

—13—13

—15—14

—17—18

JM AEROFOIL

Page 192: JM Aerofoil 50 Hz Technical

Fan Code: 140JM/50/6/12/...1400 mm 960 rev/min 12 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11848

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 500

200

400

600

800

10000 50000 100000 150000

0 20000 40000 60000 80000 100000

0

20

40

60

80

100

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

0 10 20 30 40 5005

10152025303540

16°

24°

32°

8°16°

24°

32°

102

101

103

103

102

102

104

104

105

104

106

107

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—17—19

—11—14

—9—12

—4—6

—6—5

—13—7

—18—9

—29—22

8—15—16

—9—13

—7—10

—3—6

—5—4

—10—5

—16—7

—27—20

16—16—10

—15—11

—9—7

—3—9

—7—8

—14—8

—21—9

—27—20

16—12

—7—13

—9—7—4

—3—9

—6—8

—13—6

—19—6

—26—17

24 — 36 24 — 36—5—7

—8—9

—8—7

—9—8

—9—9

—13—11

—16—14

—17—20

—2—2

—5—5

—6—4

—8—7

—8—8

—13—11

—15—13

—16—19

JM AEROFOIL

Page 193: JM Aerofoil 50 Hz Technical

Fan Code: 140JM/50/4/9/...1400 mm 1470 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11849

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 50 60 700

500

1000

1500

20000 50000 100000 150000 200000

0 20000 40000 60000 80000 100000 120000 140000

0

50

100

150

200

0

1

2

3

4

5

6

7

8

0 10 20 30 40 50 60 700

20

40

60

80

100

120

16°

24°

32°

8°16°

24°

32°

115

113

116

116

116

117

119

119

119

115

116

119

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—14—10

—16—15

—10—10

—7—10

—4—5

—8—7

—12—8

—20—15

8—11—7

—14—11

—8—8

—6—9

—3—5

—7—6

—12—7

—18—13

16—11—6

—14—10

—10—7

—5—10

—5—9

—9—10

—14—9

—21—15

16—8—3

—13—7

—8—4

—5—8

—4—9

—8—8

—13—8

—20—14

24 — 36 24 — 36—6—5

—9—8

—6—6

—9—10

—10—11

—13—14

—15—15

—17—18

—3—2

—6—7

—4—3

—8—9

—9—10

—12—13

—14—14

—16—16

If it is intended to run this fan in reverse for other than emergency operation, please refer to Fl kt Woods Ltd.

JM AEROFOIL

Page 194: JM Aerofoil 50 Hz Technical

Fan Code: 140JM/50/4/12/...1400 mm 1470 rev/min 12 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11850

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 50 60 70 800

500

1000

1500

2000

25000 50000 100000 150000 200000 250000

0 20000 40000 60000 80000 100000 120000 140000 160000

0

50

100

150

200

250

0

2

4

6

8

10

0 10 20 30 40 50 60 70 800

20406080

100120140

16°

24°

32°

8°16°

24°

32°

112

110

112

112

112

112

114

114

114

114

116

116

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—20—21

—16—18

—8—12

—9—10

—3—5

—8—6

—14—7

—22—14

8—18—19

—14—17

—6—10

—8—9

—3—3

—5—4

—13—5

—21—12

16—18—12

—16—11

—12—6

—5—11

—4—8

—9—8

—16—7

—25—14

16—15

—8—14

—9—11—3

—4—10

—3—8

—8—7

—14—4

—23—11

24 — 36 24 — 36—7—8

—6—8

—7—6

—10—10

—9—9

—11—10

—15—12

—17—17

—4—5

—3—4

—5—3

—9—9

—8—8

—11—10

—14—11

—17—16

If it is intended to run this fan in reverse for other than emergency operation, please refer to Fl kt Woods Ltd.

JM AEROFOIL

Page 195: JM Aerofoil 50 Hz Technical

Fan Code: 160JM/40/12/6/...1600 mm 480 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11867

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 30 350

50

100

150

2000 20000 40000 60000 80000 100000 120000

0 10000 20000 30000 40000 50000 60000 70000

0

5

10

15

20

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0 5 10 15 20 25 30 350

1

2

3

4

5

88

90

96

90

16°

24°

32°

8°16°

24°

32°

90

93

92

92

95

91

93

96

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—14—13

—8—13

—3—8

—6—4

—13—7

—16—9

—23—19

—29—27

8—12—10

—6—11

—2—7

—6—3

—12—7

—14—7

—22—18

—28—26

16—14

—8—12

—9—5—8

—5—7

—9—8

—12—9

—15—13

—19—17

16—12

—5—11—8

—4—7

—5—7

—8—8

—12—8

—13—12

—18—16

24 — 32 24 — 32—9—7

—6—8

—5—7

—9—8

—13—9

—17—12

—18—12

—21—14

—7—4

—6—7

—5—6

—7—6

—12—9

—15—11

—16—10

—20—13

JM AEROFOIL

Page 196: JM Aerofoil 50 Hz Technical

Fan Code: 160JM/40/12/9/...1600 mm 480 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11868

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 30 35 400

50

100

150

200

250

3000 20000 40000 60000 80000 100000 120000

0 10000 20000 30000 40000 50000 60000 70000 80000

0

5

10

15

20

25

30

0.0

0.2

0.4

0.6

0.8

1.0

1.2

0 5 10 15 20 25 30 35 40012345678

16°

24°

32°

8°16°

24°

32°

91

89

96

90

90

90

94

93

93

92

94

98

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—17—13

—10—14

—2—7

—6—4

—14—7

—17—8

—26—19

—32—28

8—14—10

—7—12

—2—7

—5—3

—13—6

—15—7

—26—19

—32—27

16—16

—6—10—11

—3—10

—7—9

—12—8

—16—7

—21—15

—25—20

16—13

—2—8—9

—2—9

—7—9

—11—7

—15—6

—19—15

—24—18

24 — 36 24 — 36—9—6

—10—8

—7—8

—7—8

—8—9

—11—11

—11—12

—14—14

—5—2

—7—5

—5—6

—6—7

—7—7

—10—10

—10—10

—13—13

JM AEROFOIL

Page 197: JM Aerofoil 50 Hz Technical

Fan Code: 160JM/50/12/12/...1600 mm 480 rev/min 12 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11870

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 30 35 400

50

100

150

200

250

300

3500 20000 40000 60000 80000 100000 120000

0 10000 20000 30000 40000 50000 60000 70000 80000

0

5

10

15

20

25

30

35

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

0 5 10 15 20 25 30 35 400123456789

16°

24°

32°

8°16°

24°

32°

92

90

100

92

90

90

93

92

93

94

96

100

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—14—17

—7—13

—3—6

—8—4

—15—8

—16—9

—27—22

—33—31

8—12—15

—6—11

—2—7

—7—4

—14—6

—14—7

—25—20

—32—29

16—17—14

—12—9

—4—10

—5—7

—9—7

—12—5

—20—16

—26—21

16—14—10

—10—6

—3—9

—5—7

—8—6

—12—4

—18—13

—24—18

24 — 36 24 — 36—11—9

—8—7

—6—7

—7—7

—9—8

—13—10

—14—14

—17—16

—8—5

—4—3

—4—6

—6—6

—8—7

—12—10

—13—12

—16—15

JM AEROFOIL

Page 198: JM Aerofoil 50 Hz Technical

Fan Code: 160JM/40/10/6/...1600 mm 575 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11871

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 30 35 400

50

100

150

200

250

3000 20000 40000 60000 80000 100000 120000

0 10000 20000 30000 40000 50000 60000 70000 80000

0

5

10

15

20

25

30

0.0

0.2

0.4

0.6

0.8

1.0

1.2

0 5 10 15 20 25 30 35 400123456789

16°

24°

32°

8°16°

24°

32°

92

94

100

94

94

97

96

96

98

95

97

100

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—17—15

—9—13

—4—9

—6—4

—11—6

—15—8

—21—15

—27—25

8—14—12

—7—11

—3—8

—5—4

—10—6

—14—7

—20—14

—26—24

16—15—10

—12—9

—6—9

—4—7

—8—8

—12—8

—14—12

—18—16

16—12

—7—11—7

—6—8

—4—7

—7—7

—11—8

—12—11

—17—15

24 — 32 24 — 32—11—8

—6—7

—5—8

—8—8

—11—9

—16—12

—18—12

—20—14

—9—6

—6—6

—5—6

—7—6

—11—9

—15—11

—16—10

—19—12

JM AEROFOIL

Page 199: JM Aerofoil 50 Hz Technical

Fan Code: 160JM/40/10/9/...1600 mm 575 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11872

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 30 35 40 450

50

100

150

200

250

300

350

4000 20000 40000 60000 80000 100000 120000 140000

0 20000 40000 60000 80000

0

5

10

15

20

25

30

35

40

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

0 5 10 15 20 25 30 35 40 4502468

101214

16°

24°

32°

8°16°

24°

32°

95

93

100

94

94

94

97

97

97

96

98

102

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—18—14

—11—16

—3—9

—5—4

—12—6

—16—7

—22—15

—30—26

8—15—11

—9—14

—3—9

—4—3

—11—5

—15—6

—22—15

—29—25

16—17

—6—12—13

—3—10

—5—9

—10—8

—15—6

—19—11

—23—18

16—14

—3—11—11

—3—8

—5—9

—9—7

—14—6

—17—11

—23—16

24 — 36 24 — 36—10

—7—11—10

—7—8

—7—8

—7—8

—11—11

—11—11

—13—14

—6—2

—8—7

—5—5

—6—7

—7—7

—10—10

—10—10

—12—12

JM AEROFOIL

Page 200: JM Aerofoil 50 Hz Technical

Fan Code: 160JM/50/10/12/...1600 mm 575 rev/min 12 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11874

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 30 35 40 450

50

100

150

200

250

300

350

400

4500 20000 40000 60000 80000 100000 120000 140000

0 20000 40000 60000 80000

0

10

20

30

40

0.0

0.5

1.0

1.5

0 5 10 15 20 25 30 35 40 4502468

10121416

16°

24°

32°

8°16°

24°

32°

96

94

104

96

94

94

97

97

97

98

100

103

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—16—19

—11—14

—3—8

—6—4

—13—7

—15—8

—24—18

—31—28

8—15—17

—8—11

—3—8

—5—3

—12—6

—13—6

—22—16

—29—26

16—18—15

—13—9

—6—11

—4—7

—7—7

—12—5

—18—12

—24—19

16—15—11

—10—6

—5—10

—4—8

—7—7

—11—4

—16—9

—22—17

24 — 36 24 — 36—11—9

—8—7

—6—8

—7—8

—8—8

—12—10

—14—13

—16—16

—8—5

—5—2

—5—6

—6—7

—7—7

—12—9

—12—12

—15—15

JM AEROFOIL

Page 201: JM Aerofoil 50 Hz Technical

Fan Code: 160JM/40/8/6/...1600 mm 720 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11858

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 500

50

100

150

200

250

300

350

400

4500 50000 100000 150000

0 20000 40000 60000 80000 100000

0

10

20

30

40

0.0

0.5

1.0

1.5

0 10 20 30 40 5002468

1012141618

16°

24°

32°

8°16°

24°

32°

97

99

104

99

99

102

101

101

104

100

102

105

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—19—16

—12—13

—5—11

—4—6

—9—5

—14—8

—18—11

—26—23

8—16—13

—9—11

—4—10

—4—5

—8—4

—13—6

—17—10

—24—22

16—15—10

—13—9

—10—9

—4—7

—6—8

—10—8

—13—10

—17—15

16—13

—7—12

—7—9—9

—4—7

—6—7

—10—8

—12—9

—16—14

24 — 3224 — 32 24 — 3224 — 32—13

—9—7—7

—6—8

—6—7

—10—8

—15—11

—17—12

—19—13

—10—6

—6—6

—6—7

—5—6

—9—8

—13—10

—15—10

—18—12

If it is intended to run this fan in reverse for other than emergency operation, please refer to Fl kt Woods Ltd.

JM AEROFOIL

Page 202: JM Aerofoil 50 Hz Technical

Fan Code: 160JM/40/8/9/...1600 mm 720 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11859

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 50 600

100

200

300

400

500

600

7000 50000 100000 150000 200000

0 20000 40000 60000 80000 100000 120000

0

10

20

30

40

50

60

70

0.0

0.5

1.0

1.5

2.0

2.5

0 10 20 30 40 50 600

5

10

15

20

25

30

16°

24°

32°

8°16°

24°

32°

99

98

105

99

98

99

102

102

102

100

103

106

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—21—19

—14—14

—5—12

—3—5

—9—6

—15—7

—19—11

—28—24

8—18—16

—12—10

—5—11

—2—3

—8—4

—14—6

—19—11

—27—23

16—19—13

—14—7

—6—10

—3—9

—8—8

—14—7

—18—8

—22—17

16—16

—9—12

—4—6—9

—3—9

—7—7

—13—6

—16—8

—21—15

24 — 36 24 — 36—10

—8—10

—8—9—8

—7—8

—7—8

—9—10

—11—11

—12—13

—6—4

—7—4

—7—6

—6—7

—6—7

—8—9

—10—9

—11—12

If it is intended to run this fan in reverse for other than emergency operation, please refer to Fl kt Woods Ltd.

JM AEROFOIL

Page 203: JM Aerofoil 50 Hz Technical

Fan Code: 160JM/50/8/12/...1600 mm 720 rev/min 12 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11861

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 50 600

100

200

300

400

500

600

7000 50000 100000 150000 200000

0 20000 40000 60000 80000 100000 120000

0

10

20

30

40

50

60

70

0.0

0.5

1.0

1.5

2.0

2.5

0 10 20 30 40 50 6005

101520253035

16°

24°

32°

8°16°

24°

32°

101

99

109

101

100

100

102

102

102

103

104

108

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—21—21

—11—14

—6—11

—3—4

—11—6

—15—8

—20—12

—29—26

8—19—19

—9—12

—6—11

—2—4

—10—4

—13—5

—18—10

—27—24

16—18—14

—14—8

—9—12

—4—8

—6—7

—11—6

—15—8

—22—18

16—15—11

—11—6

—8—11

—4—9

—5—7

—10—4

—13—5

—21—16

24 — 36 24 — 36—11—8

—10—7

—8—9

—6—8

—7—8

—11—10

—13—12

—15—15

—8—4

—7—3

—6—7

—5—7

—6—7

—11—9

—12—11

—14—14

JM AEROFOIL

Page 204: JM Aerofoil 50 Hz Technical

Fan Code: 160JM/40/6/6/...1600 mm 960 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11862

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 50 60 700

100

200

300

400

500

600

700

8000 50000 100000 150000 200000

0 20000 40000 60000 80000 100000 120000 140000

0

10

20

30

40

50

60

70

80

0.0

0.5

1.0

1.5

2.0

2.5

3.0

0 10 20 30 40 50 60 7005

10152025303540

16°

24°

32°

8°16°

24°

32°

103

105

111

106

106

109

108

108

110

106

108

111

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—21—19

—15—13

—8—13

—4—8

—7—4

—13—7

—16—9

—23—19

8—17—15

—12—11

—7—13

—2—7

—6—4

—11—6

—15—7

—22—18

16—15—12

—14—8

—12—10

—5—8

—5—7

—9—8

—13—9

—16—14

16—13

—9—12

—7—12

—9—5—8

—5—7

—8—8

—10—8

—15—13

24 — 32 24 — 32—14—10

—9—7

—7—9

—5—8

—9—8

—13—10

—17—13

—18—13

—11—6

—7—6

—6—7

—4—6

—8—8

—12—9

—15—10

—17—11

If it is intended to run this fan in reverse for other than emergency operation, please refer to Fl kt Woods Ltd.

JM AEROFOIL

Page 205: JM Aerofoil 50 Hz Technical

Fan Code: 160JM/40/6/9/...1600 mm 960 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11863

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 50 60 70 800

200

400

600

800

1000

12000 50000 100000 150000 200000 250000

0 20000 40000 60000 80000 100000 120000 140000 160000

0

20

40

60

80

100

120

0

1

2

3

4

0 10 20 30 40 50 60 70 800

10203040506070

16°

24°

32°

8°16°

24°

32°

106

105

112

106

106

106

109

109

109

107

109

113

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—24—21

—17—13

—10—15

—3—8

—7—4

—14—7

—17—9

—26—19

8—21—18

—14—10

—9—14

—1—6

—5—3

—12—6

—17—8

—25—18

16—19—13

—17—6

—11—11

—3—11

—7—9

—12—8

—17—7

—21—15

16—15

—9—14

—3—10—10

—3—10

—5—8

—11—8

—14—7

—20—13

24 — 36 24 — 36—8—8

—10—7

—10—9

—8—9

—7—9

—8—9

—12—12

—12—13

—4—3

—6—4

—8—7

—7—8

—7—7

—7—9

—10—10

—11—12

If it is intended to run this fan in reverse for other than emergency operation, please refer to Fl kt Woods Ltd.

JM AEROFOIL

Page 206: JM Aerofoil 50 Hz Technical

Fan Code: 160JM/50/6/9/...1600 mm 960 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11864

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 50 60 700

200

400

600

800

1000

12000 50000 100000 150000 200000

0 20000 40000 60000 80000 100000 120000 140000

0

20

40

60

80

100

120

0

1

2

3

4

0 10 20 30 40 50 60 700

10203040506070

16°

24°

32°

8°16°

24°

32°

105

105

113

106

106

108

110

108

109

108

109

112

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—20—20

—13—16

—8—14

—4—8

—7—4

—12—7

—14—7

—25—21

8—17—16

—10—13

—7—13

—3—7

—5—4

—11—6

—13—6

—23—19

16—18—11

—13—11

—7—10

—4—9

—8—8

—13—7

—18—7

—23—17

16—14

—8—11—7

—5—8

—3—7

—6—7

—12—5

—16—6

—21—16

24 — 36 24 — 36—11—8

—11—9

—8—8

—5—8

—7—9

—11—10

—15—12

—16—14

—8—5

—8—6

—6—6

—4—6

—6—8

—9—8

—13—10

—15—12

If it is intended to run this fan in reverse for other than emergency operation, please refer to Fl kt Woods Ltd.

JM AEROFOIL

Page 207: JM Aerofoil 50 Hz Technical

Fan Code: 160JM/50/6/12/...1600 mm 960 rev/min 12 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11865

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 50 60 70 800

200

400

600

800

1000

1200

14000 50000 100000 150000 200000 250000

0 20000 40000 60000 80000 100000 120000 140000 160000

0

20

40

60

80

100

120

140

0

1

2

3

4

5

0 10 20 30 40 50 60 70 800

1020304050607080

16°

24°

32°

8°16°

24°

32°

107

106

115

107

106

106

109

108

109

110

111

115

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8—23—22

—14—17

—7—13

—3—6

—8—5

—15—8

—17—9

—27—23

8—21—19

—12—16

—6—11

—2—6

—7—3

—12—5

—15—6

—25—21

16—17—13

—17—14

—12—10

—4—10

—5—7

—9—7

—13—6

—21—16

16—14

—9—15—12

—10—7

—4—10

—4—7

—9—6

—10—3

—19—13

24 — 36 24 — 36—9—7

—12—10

—9—8

—7—8

—7—9

—10—9

—13—11

—15—15

—6—3

—9—6

—6—6

—5—7

—6—8

—9—9

—12—10

—14—14

If it is intended to run this fan in reverse for other than emergency operation, please refer to Fl kt Woods Ltd.

JM AEROFOIL

Page 208: JM Aerofoil 50 Hz Technical

Code Motor A B C D E G H K L M N P S T V XFrame (kg)

31JM BT4/5/9 315 395 375 235 2.5 175 355 289 265 315 10 200 8 10 30 0.7 22CT5/9 315 395 375 235 2.5 175 355 289 265 315 10 200 8 10 30 0.7 27

35JM BT4/5/9 355 435 375 256 2.5 200 395 289 305 355 10 225 8 10 30 0.9 24CT5/9 355 435 375 256 2.5 200 395 289 305 355 10 225 8 10 30 0.9 28

40JM BT4/5/9 400 480 375 279 2.5 225 450 289 350 400 10 250 8 12 30 1.0 26CT5/9 400 480 375 279 2.5 225 450 289 350 400 10 250 8 12 30 1.0 30

45JM BT4/5/9 450 530 375 306 2.5 255 500 289 400 450 10 280 8 12 30 1.2 28CT5/9 450 530 375 306 2.5 255 500 289 400 450 10 280 8 12 30 1.2 32F22 450 530 520 306 3 255 500 434 400 450 10 280 8 12 30 1.2 50PM112 450 530 520 306 3 255 500 434 400 450 10 280 8 12 30 1.2 57

50JM BT5/9 500 594 375 338 2.5 290 560 280 450 500 10 315 12 12 30 1.7 28CT5/9 500 594 375 338 2.5 290 560 280 450 500 10 315 12 12 30 1.7 34F22 500 594 520 338 3 290 560 424 450 500 10 315 12 12 30 1.7 60PM112 500 594 520 338 3 290 560 424 450 500 10 315 12 12 30 1.7 67

56JM BT5/9 560 654 375 368 2.5 330 620 280 510 560 10 355 12 12 50 2.0 34CT5/9 560 654 375 368 2.5 330 620 280 510 560 10 355 12 12 50 2.0 38F22 560 654 520 368 3 330 620 424 510 560 10 355 12 12 50 2.0 62PM112 560 654 520 368 3 330 620 424 510 560 10 355 12 12 50 2.0 69

63JM BT5/9 630 724 375 403 3 375 690 289 580 630 10 400 12 12 50 2.5 48CT5/9 630 724 375 403 3 375 690 289 580 630 10 400 12 12 50 2.5 52F22 630 724 520 403 3 375 690 434 580 630 10 400 12 12 50 2.5 70PM112 630 724 520 403 3 375 690 434 580 630 10 400 12 12 50 2.5 81D132 630 724 520 440 3 375 690 434 580 630 12 400 12 12 50 4.8 117D160 630 724 711 440 6 375 690 619 580 630 12 400 12 12 50 ?? 270D180 630 724 711 440 6 375 690 619 580 630 12 400 12 12 50 ?? 270

71JM CT5/9 710 804 375 443 3 415 770 259 660 710 10 440 16 12 50 4.5 54F22 710 804 520 443 3 415 770 404 660 710 10 440 16 12 50 4.5 80PM112 710 804 520 443 3 415 770 404 660 710 10 440 16 12 50 4.5 87D132 710 804 520 480 4 415 770 404 660 710 12 440 16 12 50 5.3 168D160 710 804 711 480 6 415 770 589 660 710 10 440 16 12 50 5.3 258D180 710 804 711 480 6 415 770 589 660 710 16 450 16 12 50 7.4 280

80JM CT5/9 800 894 375 488 3 485 860 259 750 800 10 510 16 12 50 7.0 63F22 800 894 520 488 3 485 860 404 750 800 10 510 16 12 50 7.0 90PM112 800 894 520 488 3 485 860 404 750 800 10 510 16 12 50 7.0 96D132 800 894 520 525 5 485 860 400 750 800 12 510 16 12 50 7.0 192D160 800 894 711 525 6 485 860 589 750 800 12 510 16 12 50 7.0 258D180 800 894 711 525 6 485 860 589 750 800 12 510 16 12 50 8.5 300

90JM F22 900 1006 520 538 3 491 970 444 850 900 10 518 16 15 50 4.5 94PM112 900 1006 520 538 3 491 970 444 850 900 10 518 16 15 50 4.5 101D132 900 1006 520 575 5 491 970 440 850 900 12 518 16 15 50 5.3 206D160 900 1006 711 575 5 491 970 629 850 900 12 518 16 15 50 5.3 270D180 900 1006 711 575 6 491 970 629 850 900 12 518 16 15 50 5.3 312

100JM F22 1000 1106 520 588 3 547 1070 444 950 1000 10 574 16 15 50 5.3 102PM112 1000 1106 520 588 3 547 1070 444 950 1000 10 574 16 15 50 5.3 109D132 1000 1106 520 625 5 547 1070 444 950 1000 12 574 16 15 50 6.2 227D160 1000 1106 711 625 6 547 1070 539 950 1000 12 574 16 15 50 6.2 286D180 1000 1106 711 625 6 547 1070 629 950 1000 12 574 16 15 50 12.5 328

100JM/40 D160 1000 1106 750 630 6 547 1070 669 950 1000 16 574 16 15 50 12.5 330D180 1000 1106 800 630 6 547 1070 718 950 1000 16 574 16 15 50 12.5 403

JM AEROFOIL

DIMENSIONS AND WEIGHTSLONG CASED 315 - 1000 DIA - UP TO 400 HUB

60

C137

ØB

OVE

R F

LAN

GES

ØA

INSI

DE

E

AIRFLOW

FORM B

AIRFLOW

FORM A

HOLE INFOOT Ø N

K CRS2 HOLES Ø 8

D132,D160,D180 FRAMES40 DIA. HOLES FOR CONDUIT.2 EACH SIDE SUITABLE FOR 1.5"

BT,CT,F22 FRAMES23 DIA. HOLES FOR CONDUIT.2 EACH SIDE SUITABLE FOR CM20.

S No. OF HOLES ØT .EQUISPACED ON H PCD. (EACH END)

L CRS

M

SIGHT PORT

DP G

FOOT POSITIONFOR VERTICALMOUNTING

V

GUARDS OPTIONAL

MOUNTING FOOTDIM X (kg)

BT,CT,F22 FRAMES1 HOLE 20 DIA. (END OF BOX) TO SUITCM16 FOR AUXILLARY CABLES

Weight(kg)

All dimensions in mm

Page 209: JM Aerofoil 50 Hz Technical

JM AEROFOIL

61

Code Motor A B C D E G H K L M N P S T V X(kg)

50JM D80 500 594 520 338 3 290 560 424 450 500 10 315 12 12 30 2.0 52D90 500 594 520 338 3 290 560 424 450 500 10 315 12 12 30 2.0 65D100 500 594 520 338 3 290 560 424 450 500 10 315 12 12 30 2.0 74D112 500 594 520 338 3 290 560 424 450 500 10 315 12 12 30 2.0 86

56JM D80 560 654 520 368 3 330 620 424 510 560 10 355 12 12 50 2.3 56D90 560 654 520 368 3 330 620 424 510 560 10 355 12 12 50 2.3 68D100 560 654 520 368 3 330 620 424 510 560 10 355 12 12 50 2.3 78D112 560 654 520 368 3 330 620 424 510 560 10 355 12 12 50 2.3 90

63JM D80 630 724 520 403 3 375 690 424 580 630 10 400 12 12 50 2.4 63D90S/L 630 724 520 403 3 375 690 424 580 630 10 400 12 12 50 2.4 76D100 630 724 520 403 3 375 690 424 580 630 10 400 12 12 50 2.4 92D112 630 724 520 403 3 375 690 424 580 630 10 400 12 12 50 2.4 104D132S/M 630 724 620 440 4 375 690 532 580 630 10 400 12 12 50 2.4 158D160M/L 630 724 725 440 4 375 690 637 580 630 10 400 12 12 50 2.4 230

63JM/31 D132S/M 630 724 725 440 5 375 690 637 580 630 10 400 12 12 50 2.4 180D160M/L 630 724 800 440 5 375 690 712 580 630 10 400 12 12 50 2.4 248

71JM D80 710 804 520 443 3 415 770 404 660 710 10 440 16 12 50 4.5 66D90/SL 710 804 520 443 3 415 770 404 660 710 10 440 16 12 50 4.5 78D100 710 804 520 443 3 415 770 404 660 710 10 440 16 12 50 4.5 95D112 710 804 520 443 3 415 770 404 660 710 12 440 16 12 50 4.5 107D132S/M 710 804 620 480 5 415 770 532 660 710 10 440 16 12 50 4.5 163

71JM/31 D132S/M 710 804 725 480 6 415 770 637 660 710 12 440 16 12 50 4.5 195D160M/L 710 804 800 480 6 415 770 712 660 710 12 440 16 12 50 4.5 270

80JM D80 800 894 520 488 3 485 860 404 750 800 10 510 16 12 50 5.8 72D90S/L 800 894 520 488 3 485 860 404 750 800 10 510 16 12 50 5.8 85D100 800 894 520 488 3 485 860 404 750 800 10 510 16 12 50 5.8 101D112 800 894 520 488 3 485 860 404 750 800 10 510 16 12 50 5.8 113D132S/M 800 894 620 525 5 485 860 500 750 800 12 510 16 12 50 5.8 186D160M/L 800 894 725 525 6 485 860 637 750 800 12 510 16 12 50 5.8 263

80JM/31 D132S/M 800 894 725 525 5 485 860 637 750 800 12 510 16 12 50 5.8 207D160M/L 800 894 800 525 6 485 860 712 750 800 12 510 16 12 50 5.8 282

90JM D100 900 1006 520 488 3 491 970 404 850 900 10 518 16 15 50 5.8 107D112 900 1006 520 488 3 491 970 404 850 900 10 518 16 15 50 5.8 119D132S/M 900 1006 620 525 5 491 970 500 850 900 12 518 16 15 50 5.8 198D160M/L 900 1006 725 525 6 491 970 637 850 900 12 518 16 15 50 5.8 278

100JM D100 1000 1106 520 488 3 547 1070 404 950 1000 10 574 16 15 50 6.2 112D112 1000 1106 520 488 3 547 1070 404 950 1000 10 574 16 15 50 6.2 125D132S/M 1000 1106 620 525 5 547 1070 500 950 1000 12 574 16 15 50 6.2 209D160M/L 1000 1106 725 525 5 547 1070 637 950 1000 12 574 16 15 50 6.2 236

100JM/31 D132S/M 1000 1106 725 525 6 547 1070 637 950 1000 12 574 16 15 50 6.2 290D160M/L 1000 1106 800 525 6 547 1070 712 950 1000 12 574 16 15 50 6.2 313

C

137 E

HOLES INFOOT Ø N

K CRS

2 HOLES 23 DIA (EACH SIDE).SUITABLE FOR CM20 GLANDS

S No OF HOLES DIA T EQUISPACED ON HPCD (EACH END)

L CRS

DP G

FOOT POSITION FORVERTICAL MOUNTING

V

X (kg)

ØB

OVE

R F

LAN

GES

AIRFLOW

FORM B

AIRFLOW

FORM A

ØA

INSI

DE

Weight(kg)

Dimensions in mm

DIMENSIONS AND WEIGHTS - FOOT MOUNTEDLONG CASED 500 - 1000 DIA - UP TO 315 HUB

Page 210: JM Aerofoil 50 Hz Technical

31JM BT4/5 315 395 301 225 2.5 355 8 10 - 137 13.5BT9 315 395 333 225 2.5 355 8 10 - 137 15CT5 315 395 308 225 2.5 355 8 10 - 137 15.5CT9 315 395 348 225 2.5 355 8 10 - 137 20

35JM BT4/5 355 435 301 225 2.5 395 8 10 - 137 14BT9 355 435 333 225 2.5 395 8 10 - 137 15.5CT5 355 435 308 225 2.5 395 8 10 - 137 16.5CT9 355 435 348 225 2.5 395 8 10 - 137 20.5

40JM BT4/5 400 480 301 225 2.5 450 8 12 - 137 15BT9 400 480 333 225 2.5 450 8 12 - 137 16.5CT5 400 480 308 225 2.5 450 8 12 - 137 17CT9 400 480 348 225 2.5 450 8 12 - 137 21

45JM BT4/5 450 530 301 225 2.5 500 8 12 - 137 17BT9 450 530 333 225 2.5 500 8 12 - 137 18.5CT5 450 530 308 225 2.5 500 8 12 - 137 19CT9 450 530 348 225 2.5 500 8 12 - 137 23F22 450 530 444 225 3 500 8 12 - 137 40PM112 450 530 392 225 3 500 8 12 - 137 47

50JM BT5 500 594 301 225 2.5 560 12 12 - 137 19BT9 500 594 333 225 2.5 560 12 12 - 137 20CT5 500 594 308 225 2.5 560 12 12 - 137 20.5CT9 500 594 348 225 2.5 560 12 12 - 137 25F22 500 594 444 225 3 560 12 12 - 137 43PM112 500 594 392 225 3 560 12 12 - 137 50

56JM BT5 560 654 301 225 2.5 620 12 12 - 137 20BT9 560 654 333 225 2.5 620 12 12 - 137 21.5CT5 560 654 308 225 2.5 620 12 12 - 137 22CT9 560 654 348 225 2.5 620 12 12 - 137 26F22 560 654 444 225 3 620 12 12 - 137 45PM112 560 654 392 225 3 620 12 12 - 137 52

63JM BT5 630 724 301 225 3 690 12 12 - 137 34BT9 630 724 333 225 3 690 12 12 - 137 35.5CT5 630 724 308 225 3 690 12 12 - 137 36CT9 630 724 348 225 3 690 12 12 - 137 40F22 630 724 404 225 3 690 12 12 - 137 49PM112 630 724 459 225 3 690 12 12 - 200 60D132 630 724 445 260 4 690 12 12 160 450 94D160 630 724 575 260 4 690 12 12 200 450 172

63JM/31 D160 630 724 610 300 5 690 12 12 225 450 198D180 630 724 610 300 5 690 12 12 225 450 198

H

JM AEROFOIL

62

DIMENSIONS AND WEIGHTSSHORT CASED 315 - 1000 DIA - UP TO 400 HUB

Weight(kg)

Code MotorFrame A B C D E S T V W

All dimensions in mm

S No. OF HOLES DIA TEQUISPACED ON H PCD.(EACH END0

C137

ØB

OVE

R F

LAN

GES

ØA

INSI

DE

E

GUARDS OPTIONALEITHER END

AIRFLOW

FORM B

AIRFLOW

FORM A

D

D132 FRAMESCABLE ENTRY 2 - KNOCKOUTS 26 DIA FOR CM25

D160/20/23/26/28/32 FRAMES2 - KNOCKOUTS FOR CM32

D160/L/LM/LMA/LBK FRAMES2 - HOLES TAPPED CM32

V

* HOLE

*WHERE IMPELLER SIDE GUARD IS FITED ON THE MOTORSIDE THE GUARD ENCLOSES THE MOTOR. A HOLE 15 DIAIS PROVIDED IN THE DUCT FOR CUSTOMERS SUPPLY LEADS.

*WHERE A MOTOR SIDE GUARD IS FITTEDWITH D132 & D160 FRAMES THE GUARD ALSOENCLOSES MOTOR. A HOLE 22 DIA. FOR LEADSIS PROVIDED IN THE SAME POSITION ON DUCT.

F22 FRAMESENTRY FOR CM25 CONDUITSUITABLE FOR 8 - 13 mm DIA CABLE

BT/CT FRAMES1 COMPRESSION GLAND CM20/CM161 Phase AND 3 Phase SUPPLY.SUITABLE FOR 7-10.5 CABLE.

W

D132 & D160TAPPED FOR CM40

Page 211: JM Aerofoil 50 Hz Technical

71JM CT5 710 804 308 225 3 770 16 12 - 137 38CT9 710 804 348 225 3 770 16 12 - 137 42F22 710 804 444 225 3 770 16 12 - 137 59PM112 710 804 392 225 3 770 16 12 - 200 66D132 710 804 478 260 4 770 16 12 187 350 139D160 710 804 644 300 4 770 16 12 225 350 224

71JM/31 D160 710 804 644 300 5 770 16 12 225 350 254D180 710 804 665 300 6 770 16 12 243 350 257

80JM CT5 800 894 308 225 3 860 16 12 - 137 43CT9 800 894 348 225 3 860 16 12 - 137 47F22 800 894 444 225 3 860 16 12 - 137 65PM112 800 894 392 225 3 860 16 12 - 200 72D132 800 894 478 260 4 860 16 12 187 350 174D160 800 894 610 260 4 860 16 12 225 350 258

80JM/31 D160 800 894 610 300 4 860 16 12 225 350 263D180 800 894 665 300 6 860 16 12 243 350 295

90JM F22 900 1006 444 225 3 970 16 15 - 137 67PM112 900 1006 392 225 3 970 16 15 - 200 74D132 900 1006 438 300 5 970 16 15 187 310 143D160 900 1006 609 300 5 976 16 15 225 365 276

100JM F22 1000 1106 444 225 3 1070 16 15 - 137 72PM112 1000 1106 392 225 3 1070 16 15 - 200 79D132 1000 1106 478 300 5 1070 16 15 187 201 190D160 1000 1106 610 300 5 1070 16 15 225 420 291D180 1000 1106 700 350 6 1070 16 15 243 370 350

100M/40 D160 1000 1106 660 350 6 1070 16 15 225 372 274D180 1000 1106 742 350 6 1070 16 15 243 427 347

JM AEROFOIL

63

HWeight

(kg)Code Motor

Frame A B C D E S T V W

DIMENSIONS AND WEIGHTSSHORT CASED 315 - 1000 DIA - UP TO 400 HUB

All dimensions in mm

Page 212: JM Aerofoil 50 Hz Technical

JM AEROFOIL

64

50JM D80 500 594 401 225 2.5 560 12 12 - 350 43D90 500 594 453 225 2.5 560 12 12 - 350 56D100 500 594 466 225 3 560 12 12 - 350 65D112 500 594 482 225 3 560 12 12 - 350 76

56JM D80 560 654 401 225 2.5 620 12 12 - 350 44D90 560 654 453 225 2.5 620 12 12 - 350 57D100 560 654 466 225 3 620 12 12 - 350 66D112 560 654 483 225 3 620 12 12 - 350 82

63JM D80 630 724 401 225 3 690 12 12 - 350 46D90S/L 630 724 453 225 3 690 12 12 - 350 61D100 630 724 466 225 3 690 12 12 - 350 77D112 630 724 483 225 3 690 12 12 - 350 93D132S/M 630 724 594 260 4 690 12 12 - 425 134D160M/L 630 724 696 260 4 690 12 12 - 425 209

63JM/31 D132S/M 630 724 594 260 4 690 12 12 225 425 139D160M/L 630 724 688 300 5 690 12 12 225 425 214

71JM D80 710 804 401 225 3 770 16 12 - 350 50D90 710 804 453 225 3 770 16 12 - 350 63D100 710 804 466 260 4 770 16 12 - 350 72D112 710 804 483 260 4 770 16 12 - 350 97D132 710 804 594 260 4 770 16 12 187 425 137

71JM/31 D160 710 804 594 260 4 770 16 12 225 425 152D180 710 804 688 300 5 770 16 12 243 425 218

80JM D80 800 894 401 225 3 860 16 12 - 350 56D90 800 894 453 225 3 860 16 12 - 350 69D100 800 894 466 260 4 860 16 12 - 350 78D112 800 894 483 260 4 860 16 12 - 350 99D132 800 894 594 260 4 860 16 12 187 425 142D160 800 894 696 300 4 860 16 12 225 425 210

80JM/31 D160 800 894 594 260 4 860 16 12 225 425 152D180 800 894 688 300 5 860 16 12 243 425 220

90JM D100 900 1006 466 260 4 970 16 15 - 350 87D112 900 1006 483 260 4 970 16 15 - 350 106D132 900 1006 594 260 4 970 16 15 187 425 162D160 900 1006 696 300 4 970 16 15 225 425 230

100JM D100 1000 1106 466 260 4 1070 16 15 - 350 91D112 1000 1106 483 260 4 1070 16 15 - 350 111D132 1000 1106 594 260 4 1070 16 15 187 425 170D160 1000 1106 696 300 4 1070 16 15 225 425 238

100M/31 D132 1000 1106 594 260 4 1070 16 15 225 425 176D160 1000 1106 688 300 5 1070 16 15 225 425 244

HWeight

(kg)Code Motor A B C D E S T V W

Dimensions in mm

= =

C

137 D W

E

AIRFLOW

FORM B

AIRFLOW

FORM A

GUARD(OPTIONAL)

D80-D100 MOTORS2 x CM20 CONDUIT ENTRIESD112-D132 MOTORS2 x CM25 CONDUIT ENTRIESD160 MOTORS2 x CM32 CONDUIT ENTRIES

WHERE IMPELLER SIDE GUARD ISFITTED ON THE MOTOR SIDE OR THEGUARD ENCLOSES THE MOTOR AHOLE 19 DIA IS PROVIDED IN THEDUSCT FOR CUSTOMERS SUPPLYLEADS.

ØB

OVE

R F

LAN

GES

ØA

INSI

DE

S No OF HOLES DIA T EQUISPACED ON HPCD (EACH END)

DIMENSIONS AND WEIGHTS - FOOT MOUNTEDSHORT CASED 500 - 1000 DIA - UP TO 315 HUB

Page 213: JM Aerofoil 50 Hz Technical

112JM/40 D160 1120 1258 350 656 685 1190 698 1070 1120 710 20 15 490 385 D180 1120 1258 350 656 685 1190 698 1070 1120 710 20 15 490 405 D200 1120 1258 350 756 685 1190 838 1070 1120 710 20 15 630 480 D225 1120 1258 350 756 685 1190 838 1070 1120 710 20 15 630 530

112JM/50 D160 1120 1258 350 656 685 1190 698 1070 1120 710 20 15 490 413 D180 1120 1258 350 656 685 1190 698 1070 1120 710 20 15 490 433 D200 1120 1258 350 756 685 1190 838 1070 1120 710 20 15 630 508 D225 1120 1258 350 756 685 1190 838 1070 1120 710 20 15 630 558

125JM/40 D160 1250 1388 350 711 750 1320 698 1150 1250 800 20 15 490 415 D180 1250 1388 350 711 750 1320 698 1150 1250 800 20 15 490 475 D200 1250 1388 350 811 750 1320 838 1150 1250 800 20 15 630 525 D225 1250 1388 350 811 750 1320 838 1150 1250 800 20 15 630 575

125JM/50 D160 1250 1388 350 711 750 1320 698 1150 1250 800 20 15 490 443 D180 1250 1388 350 711 750 1320 698 1150 1250 800 20 15 490 493 D200 1250 1388 350 811 750 1320 838 1150 1250 800 20 15 630 553 D225 1250 1388 350 811 750 1320 838 1150 1250 800 20 15 630 593

140JM/40 D160 1400 1538 350 786 850 1470 698 1300 1400 900 20 15 490 470 D180 1400 1538 350 786 850 1470 698 1300 1400 900 20 15 490 513 D200 1400 1538 350 886 850 1470 838 1300 1400 900 20 15 630 557 D225 1400 1538 350 886 850 1470 838 1300 1400 900 20 15 630 595

140JM/50 D160 1400 1538 350 786 850 1470 698 1300 1400 900 20 15 490 498 D180 1400 1538 350 786 850 1470 698 1300 1400 900 20 15 490 541 D200 1400 1538 350 886 850 1470 838 1300 1400 900 20 15 630 595 D225 1400 1538 350 886 850 1470 838 1300 1400 900 20 15 630 623

160JM/40 D160 1600 1760 350 886 950 1680 698 1300 1600 1000 24 20 490 571 D180 1600 1760 350 886 950 1680 698 1500 1600 1000 24 20 490 591 D200 1600 1760 350 986 950 1680 838 1500 1600 1000 24 20 630 638 D225 1600 1760 350 986 950 1680 838 1500 1600 1000 24 20 630 676

160JM/50 D160 1600 1760 350 886 950 1680 698 1500 1600 1000 24 20 490 599 D180 1600 1760 350 886 950 1680 698 1500 1600 1000 24 20 490 619 D200 1600 1760 350 986 950 1680 838 1500 1600 1000 24 20 630 666 D225 1600 1760 350 986 950 1680 838 1500 1600 1000 24 20 630 704

JM AEROFOIL

65

DIMENSIONS AND WEIGHTSLONG CASED 1120 - 1600 DIA 400 & 500 HUB

AIRFLOW

FORM B

AIRFLOW

FORM A

DIA

. OVE

R FL

ANGE

SB

DIA

. INS

IDE

A

C

M

CRSL

GP

K CRS

W

6

D34 DIA.2 HOLES EACH SIDE(OPTIONAL).WHEN FITTED.TERMINAL BOX

= =

(EACH END)EQUI-SPACED ON H PCD.S No. OF HOLES T DIA.

MOUNTING.FOR VERT.POSITIONFOOT

IN FOOT.HOLES14 DIA

50

137

H

Fan OnlyMax FrameWeight kg

CodeMotorFrame A B C D G P S T W

All dimensions in mm

K L M

Page 214: JM Aerofoil 50 Hz Technical

JM AEROFOIL

66

DIMENSIONS AND WEIGHTS - FOOT MOUNTEDSHORT CASED 1120 - 1600 DIA 400 & 500 HUB

E

B DI

A OV

ER F

LANG

ES

A IN

SIDE

DIA

D

C137

W

DF250, 2XPg42 or 2XCM50 DF225, 2XPg36 or 2XCM40

T-BOX ENTRIES. DF160-200, 2XPg29 or 2XCM32 A PLUGGED HOLE IN THE DUCT CAN BEUSED FOR CUSTOMERS SUPPLY LEADS,51 DIA.

= =S No HOLES T DIAEQUI-SPACED ONH PCD. (EACH END)

OPTIONALGUARDS

FORM B

AIRFLOW

FORM A

AIRFLOW

TERMINAL BOX WHEN FITTED.

(OPTIONAL).

2 HOLES EACH SIDE.

112JM DF160M/L 1120 1258 760 350 6 1190 20 15 425 276 304DF180M/L 1120 1258 930 350 6 1190 20 15 700 296 324DF200L 1120 1258 858 350 6 1190 20 15 570 350 378DF225S/M 1120 1258 925 350 6 1190 20 15 700 400 428DF250M 1120 1258 1003 350 6 1190 20 15 700 600 628

125JM DF160M/L 1250 1388 760 350 6 1320 20 15 425 290 318DF180M/L 1250 1388 930 350 6 1320 20 15 700 345 373DF200L 1250 1388 858 350 6 1320 20 15 570 370 398DF225S/M 1250 1388 925 350 6 1320 20 15 700 420 448DF250M 1250 1388 1003 350 6 1320 20 15 700 620 648

140JM DF160M/L 1400 1538 760 350 6 1470 20 15 425 333 361DF180M/L 1400 1538 930 350 6 1470 20 15 700 376 404DF200L 1400 1538 858 350 6 1470 20 15 570 401 429DF225S/M 1400 1538 925 350 6 1470 20 15 700 439 469DF250M 1400 1538 1003 350 6 1470 20 15 700 639 669

160JM DF160M/L 1600 1760 760 350 6 1680 24 20 425 406 434DF180M/L 1600 1760 930 350 6 1680 24 20 700 426 454DF200L 1600 1760 858 350 6 1680 24 20 570 441 469DF225S/M 1600 1760 925 350 6 1680 24 20 700 479 507DF250M 1600 1760 1003 350 6 1680 24 20 700 679 707

H

FanWeight (kg)

400 HubCode Motor

Frame A B C D E S T WFan

Weight (kg)500 Hub

All dimensions in mm

Page 215: JM Aerofoil 50 Hz Technical

JM AEROFOIL

ANCILLARIES

67

SILENCER- B TYPE

ØB

ØA

C

Tapped hole tomatch fan flange

POD - TYPE C ONLYPCD

Suitablefor fan

ØA B CWeight (kg)

B type C type

315 415 315 10 13355 455 355 12 15400 500 400 15 18450 600 450 20 24500 650 500 25 29

560 710 560 30 35630 780 630 35 42710 860 710 44 53800 1000 800 55 66900 1100 900 70 84

1000 1200 1000 82 1001120125014001600

1320 1120 100 1181450 1219 127 1471600 1400 193 2201800 1600 311 362

The above silencers give the approximate dB(A) reductions:-B Type diameter length - 7 to 10 dB(A)C Type 1 diameter length - 12 to 15dB(A)For full acoustic details contact ourWoods Acoustic Division +44 (0)1206 544122

D E F GWeight (kg)

MatchingFlange

FlexibleConnection

Damper

315 32 110 225 - 1.1 3.3 8355 32 110 225 - 1.3 3.9 9400 32 110 225 17 1.5 4.5 10450 32 110 225 39 1.7 5.0 12500 32 110 225 75 2.0 5.5 16560 32 110 225 125 2.3 6.8 18630 50 160 225 176 3.0 7.5 20710 50 160 225 210 3.2 8.1 23800 50 160 225 270 3.6 9.1 27900 50 160 225 305 4.1 10.4 31

1000 50 160 225 345 4.6 11.6 36

112012501400

1600

51 165 400 225 5.2 12.9 15051 165 400 290 5.8 14.4 16651 165 430 33551 165 435 435

11.9 24.4 27014.8 30.3 300

Suitablefor fan

ØAD E F

22

G

MATCHINGFLANGE

FLEXIBLECONNECTOR

DAMPER

SPEED CONTROLLER

A C

D

B

124 124 60 52

Typ A B C D

ME1.1 104 83 55 40

ME1.3 148 87 62 47ME1.6 148 87 62 47

MT1.1

MT1.5 160 270 196 161MT1.8 160 270 196 161

MT3.0.5 160 270 196 161

MT3.1 160 270 196 161

MT3.2 160 270 196 161ME3.2D 225 192 96 80ME1.12 210 180 81 65

MT1.12 236 316 188 153

SPEED CONTROLLER

Page 216: JM Aerofoil 50 Hz Technical

Suitable Weightfor fan Type C kg (max.)ØA315 I 137 1.2315 IV 30 0.5355 I 137 1.4355 IV 30 0.5400 I 137 1.6400 IV 30 0.6450 I 137 1.8450 II 137 1.6450 IV 30 0.6500 I 137 2.0500 II 137 1.8500 IV 30 0.7560 I 137 2.2560 II 137 2.0560 IV 50 1.0630 I 137 2.8630 II 137 2.6630 III 370 3.0630 IV 50 1.2710 I 137 3.2710 II 137 3.0710 III 370 3.4710 IV 50 1.4800 I 137 3.5800 II 137 3.3800 III 370 3.9800 IV 50 1.5900 I 137 4.2900 II 137 4.2900 III 310 4.8900 IV 50 1.71000 I 137 5.01000 II 137 4.81000 III 310 5.61000 IV 50 2.01120 I 137 7.11120 III 572 11.81120 IV 50 6.91250 I 137 6.41250 III 572 12.01250 IV 50 6.41400 I 137 8.01400 III 572 13.51400 IV 50 7.11600 I 137 9.01600 III 702 18.91600 IV 50 8.8

JM AEROFOIL

ANCILLARIES

68

CCC C

220 Dia. cut outat centre

Type IImpeller Side (all)

& Motor Side(BT & CT)

Type IIMotor Side

(S Type)(F22)

Type IIIMotor Side

(S Type)(D132 & above)

Type IVBellmouth & Motor Side(S Type all)

C

ØD Ø

A

Grillage fixingtrous ØT

Diamètre deperçage des brid

Adaptablesur

ventilateurstype A

C D Poids enkg

315 65 379 1.0355 85 423 1.2400 80 480 1.5450 95 536 2.0500 87 600 3.2560 100 668 4.0630 108 757 4.8710 126 857 5.4800 134 957 6.8900 150 1077 8.0

1000 167 1199 17.8112012501400

1600

188 1349 19.9210 1504 25.0250 1680 31.0260 1906 46.0

BELLMOUTH

GUARDS

Ø J

E

CL

F

A

B

SUITABLE FORH FIXING

K

VIBRATION ISOLATORS

19.100.Yellow 80 45 5 32 57 M8 41 12 9 5-28

19.100.Blue 80 45 5 32 57 M8 41 12 9 9-50

19.100.Red 80 45 5 32 57 M8 41 12 9 15-80

19.101.Yellow 95 60 5 45 71 M10 56 14 9 15-110

19.101.Blue 95 60 5 45 71 M10 56 14 9 23-180

19.101.Red 95 60 5 45 71 M10 56 14 9 35-280

19.102.Yellow 150 86 6 70 115 M12 82 22 11 19-150

19.102.Blue 150 86 6 70 115 M12 82 22 11 34-260

19.102.Red 150 86 6 70 115 M12 82 22 11 48-400

Type A B C E F H J K L Load

Range (kg)

Page 217: JM Aerofoil 50 Hz Technical

JM AEROFOIL

USEFUL INFORMATION

69

FAN LAWSSPEED CHANGE – CONSTANT SIZE – CONSTANT DENSITYVolume Flow ∝ Rotational SpeedPressure (Static, Dynamic and Total) ∝ (Rotational Speed)2

Power Absorbed ∝ (Rotational Speed)3

SIZE CHANGE – CONSTANT SPEED – CONSTANT DENSITY(For geometrically similar fans only)Volume Flow ∝ (Impeller Diameter)3

Pressure (Static, Dynamic and Total) ∝ (Impeller Diameter)2

Power Absorbed ∝ (Impeller Diameter)5

DENSITY CHANGE – CONSTANT SPEED – CONSTANT SIZEVolume Flow = No changePressure (Static, Dynamic and Total) ∝ DensityPower Absorbed ∝ Density

The laws can be combined where simultaneous changes in size, speed and density are required.

AIR DENSITYStandard Air density is 1.2kg/m3

One condition that gives Standard Air is:16°C, 100 kPa barometric pressure, 65% relative humidity.

CHANGE DUE TO TEMPERATURENew Density = Old Density x kg/m3

Change due to altitude

New Density = Old Density x kg/m3

Where H = Height above sea level in metres

PRESSUREIt is possible to convert from Total Pressure (PF) to Static Pressure (PsF) using the following equation(s):-

Total Pressure (PF) = Static Pressure (PsF) + Dynamic Pressure (PdF)

and Static Pressure (PsF) = Total Pressure (PF) - Dynamic Pressure (PdF)

Dynamic Pressure (PdF) is also known as Velocity Pressure (Pv) and this is a function ofVolume Flow (qv) and fan outlet area (m2). This can be calculated using:-

Dynamic Pressure (PdF) = 0.5ρ V2 (Pa)

Where ρ = Air Density (kg/m3) - Standard is 1.2 kg/m3

V = Air Velocity (m/s)

Air Velocity - V = qv x 4 where d is the diameter of the fan (m)

π d2 qv = Volume Flow (m3/s)

ABSORBED POWERAbsorbed Power = kW

273 + Old Temperature °C

273 + New Temperature °C{288 - 0.00649 H

288

4.256

Volume flow (m3/s x Total Pressure (Pa)

Total Efficiency x10

{

{ {

{ {

Page 218: JM Aerofoil 50 Hz Technical

A Fläkt Woods Company

Fläkt Woods Limited Tufnell Way Colchester CO4 5AR UK

t +44 (0)1206 544122 f +44 (0)1206 574434e [email protected] w www.flaktwoods.com

Due to a policy of continuous development and improvement the right is reserved to supply products which may differ from thoseillustrated and described in this publication. Certified dimensions will be supplied on request on receipt of order.© Copyright 2002 Fläkt Woods Limited