key utility key... · combined water sewer assumed foul water sewer route electric above ground...

1
LP TP GRASS GRASS GRASS GRASS GRASS GRASS GRASS GRASS TARMAC TARMAC GRASS GRASS GRASS GRASS UNMADE GROUND FWS FOUL WATER SEWER WATER RISER WR METER MARKER SOFFIT GAS RISER GAS VALVE INVERT DEPTH INVERT LEVEL KILO VOLT LAMP POST LOW VOLTAGE MANHOLE OVERHEAD POLYETHYLENE RODDING EYE INSPECTION COVER STOP COCK SOIL PIPE STOP VALVE UNABLE TO LIFT WATER LEVEL WASH OUT UNABLE TO TRACE RAIN WATER PIPE TAKEN FROM RECORDS SURFACE WATER SEWER GULLY PE SOF UTL UTT SWS RWP TFR RE SC SP SV WL WO GR O/H GV IC Id IL KV LP MH MT MK LV GY DISUSED ASSUMED ROUTE AIR VALVE BACK DROP BRITISH TELECOM COVER LEVEL ABBREVIATIONS CABLE RISER DUCTILE IRON END OF TRACE EARTH ROD FIRE HYDRANT DEPTH OF SERVICE ASSUMED CONNECTION FUEL TANK FILL POINT EOT FFP CL CR d DI DIS ER FH (AC) (AR) AV BD BT REDUNDANT SERVICE RED BOLLARD BO BOLLARD LIGHT BOL BELISHA BEACON BB TRAFFIC LIGHT TL TRAFFIC LIGHT COVER TLC LAMP HOLE LH ELECTRIC POLE EP LOOP DETECTOR LD TELECOM POLE TP HIGH VOLTAGE HV COMBINED WATER SEWER CWS PIPE TO GROUND PTG INTERCEPTOR INT BASE LEVEL BL CONTROL BOX CB ABOVE GROUND A/G GROUND PENETRATING RADAR GPR CAST IRON CI SPUN IRON SI VITRIFIED CLAY VC POLYVINYL CHLORIDE PVC ASBESTOS CEMENT ASB MONITORING WELL M/WELL VENT PIPE VP CABLE TELEVISION CATV DRAINAGE CHANNEL DCH UNABLE TO SURVEY UTS UTILITY KEY LINETYPES DISCLAIMER KEY CHANNEL LINE BUILDING BARRIER CONCRETE EDGE FENCE - METAL FENCE - POST & RAIL WALL VERGE HEDGE TRACK FOOTPATH FENCE - CHAIN LINK FENCE - WOODEN SURVEY STATION GATE EAVES EAVES STN 1 Barrier Barrier 40.452 40.441 56.324 TREE 56.324 CLIENT DRAWING TITLE PROJECT TITLE DATE APPROVED SURVEYED BY SCALE AT A1 REV PROJECT No. SHEET No. DRAWN BY GRID/DATUM REV AMENDMENT DRAWN CHECKED NOTES LINETYPES Unless otherwise stated, all services shown on this plan have been surveyed using approved detectors and the connections between manholes, if not traced, are assumed to be direct. No guarantee can be given that all services have been shown. In ideal conditions the depth accuracies for the underground utilities located is +/- 10% of depth. Utilities traced using GPR techniques show depths approximately from ground level to the top of the utility. Utilities traced using Electromagnetic techniques provide an estimated depth which is measured from ground level to the centre of the utility. Drainage and pipes traced using Sonde Electromagnetic techniques show depths at approximately the Invert Level. Where services are shown as 'Taken From Records' on the drawing we are not liable for any loss that may arise due to a lack of accuracy in that guided information. Due to BT's policy we are not permitted to lift their inspection chamber covers. Reference should be made to the methodology used on site as detailed within the latest version of SiteScan Procedures for Utility Location Surveys. SiteScan recommend that all excavations are to be carried out in accordance with HSG 47 (Avoiding Danger from Underground Services). Plan accuracies of the order of + or - 150mm may be achieved but this figure will depend on the depth of the service below ground level. Where similar services run in close proximity, separation may be impossible. Successful tracing of non-metallic pipes may be limited. Existing record information showing underground services is often incomplete and of doubtful accuracy. It should be regarded only as an indication and cannot be guaranteed. WATER BELOW GROUND UNKNOWN BELOW GROUND BT ASSUMED ROUTE BT BELOW GROUND ELECTRIC ASSUMED ROUTE BT ABOVE GROUND STORM WATER SEWER ASSUMED COMBINED WATER SEWER ROUTE UNKNOWN ABOVE GROUND COMBINED WATER SEWER ASSUMED FOUL WATER SEWER ROUTE ELECTRIC ABOVE GROUND ELECTRIC BELOW GROUND FOUL WATER SEWER GAS BELOW GROUND WATER ASSUMED ROUTE GAS ASSUMED ROUTE WATER ABOVE GROUND COMMS ABOVE GROUND COMMS BELOW GROUND SURVEY BOUNDARY CATV ABOVE GROUND ASSUMED STORM WATER SEWER ROUTE CATV BELOW GROUND REINSTATEMENT SCAR CATV ASSUMED ROUTE COMMS ASSUMED ROUTE GAS ABOVE GROUND GPR BELOW GROUND Information to build on SUITE 5 VITA HOUSE FISH QUAY NORTH SHIELDS NE30 1JA T: 0191 257 2911 www.sitescanltd.com TOPOGRAPHICAL SURVEY TYNE AND WEAR HEBBURN CAMPBELL PARK ROAD GVA 1:250 @ A1 24.02.17 NG P17042 4/4 A NR NR OS N

Upload: others

Post on 20-Jun-2020

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: KEY UTILITY KEY... · combined water sewer assumed foul water sewer route electric above ground electric below ground foul water sewer gas below ground water assumed route ... suite

LP

TP

GRASS

GRASS

GRASS

GRASS

GRASS

GRASS

GRASS

GRASS

TARMAC

TARMAC

GRASS

GRASS

GRASS

GRASS

UNMADE GROUND

FWS FOUL WATER SEWER

WATER RISERWR

METER

MARKER

SOFFIT

GAS RISER

GAS VALVE

INVERT DEPTH

INVERT LEVEL

KILO VOLT

LAMP POST

LOW VOLTAGE

MANHOLE

OVERHEAD

POLYETHYLENE

RODDING EYE

INSPECTION COVER

STOP COCK

SOIL PIPE

STOP VALVE

UNABLE TO LIFT

WATER LEVEL

WASH OUT

UNABLE TO TRACE

RAIN WATER PIPE

TAKEN FROM RECORDS

SURFACE WATER SEWER

GULLY

PE

SOF

UTL

UTT

SWS

RWP

TFR

RE

SC

SP

SV

WL

WO

GR

O/H

GV

IC

Id

IL

KV

LP

MH

MT

MK

LV

GY

DISUSED

ASSUMED ROUTE

AIR VALVE

BACK DROP

BRITISH TELECOM

COVER LEVEL

ABBREVIATIONS

CABLE RISER

DUCTILE IRON

END OF TRACE

EARTH ROD

FIRE HYDRANT

DEPTH OF SERVICE

ASSUMED CONNECTION

FUEL TANK FILL POINT

EOT

FFP

CL

CR

d

DI

DIS

ER

FH

(AC)

(AR)

AV

BD

BT

REDUNDANT SERVICERED

BOLLARDBO

BOLLARD LIGHTBOL

BELISHA BEACONBB

TRAFFIC LIGHT TL

TRAFFIC LIGHT COVERTLC

LAMP HOLELH

ELECTRIC POLEEP

LOOP DETECTORLD

TELECOM POLETP

HIGH VOLTAGEHV

COMBINED WATER SEWERCWS

PIPE TO GROUNDPTG

INTERCEPTORINT

BASE LEVELBL

CONTROL BOXCB

ABOVE GROUNDA/G

GROUND PENETRATING RADARGPR

CAST IRONCI

SPUN IRONSI

VITRIFIED CLAYVC

POLYVINYL CHLORIDEPVC

ASBESTOS CEMENTASB

MONITORING WELLM/WELL

VENT PIPEVP

CABLE TELEVISIONCATV

DRAINAGE CHANNELDCH

UNABLE TO SURVEYUTS

UTILITY KEY

LINETYPES

DISCLAIMER

KEY

CHANNEL LINE

BUILDING

BARRIER

CONCRETE EDGE

FENCE - METAL

FENCE - POST & RAIL

WALL

VERGE

HEDGE

TRACK

FOOTPATHFENCE - CHAIN LINK

FENCE - WOODEN

SURVEY STATION

GATE

EAVESEAVES

STN 1

BarrierBarrier

40.452 40.441

56.324

TREE

56.324

CLIENT

DRAWING TITLE

PROJECT TITLE

DATE

APPROVEDSURVEYED BY

SCALE AT A1

REVPROJECT No. SHEET No.

DRAWN BY

GRID/DATUM

REV AMENDMENTDRAWN

CHECKED

NOTES

LINETYPES

Unless otherwise stated, all services shown on this plan have been surveyed using approved detectors and the connections between

manholes, if not traced, are assumed to be direct.

No guarantee can be given that all services have been shown.

In ideal conditions the depth accuracies for the underground utilities located is +/- 10% of depth.

Utilities traced using GPR techniques show depths approximately from ground level to the top of the utility. Utilities traced using

Electromagnetic techniques provide an estimated depth which is measured from ground level to the centre of the utility. Drainage and

pipes traced using Sonde Electromagnetic techniques show depths at approximately the Invert Level.

Where services are shown as 'Taken From Records' on the drawing we are not liable for any loss that may arise due to a lack of

accuracy in that guided information.

Due to BT's policy we are not permitted to lift their inspection chamber covers.

Reference should be made to the methodology used on site as detailed within the latest version of SiteScan Procedures for Utility

Location Surveys.

SiteScan recommend that all excavations are to be carried out in accordance with HSG 47 (Avoiding Danger from Underground

Services).

Plan accuracies of the order of + or - 150mm may be achieved but this figure will depend on the depth of the service below ground

level. Where similar services run in close proximity, separation may be impossible. Successful tracing of non-metallic pipes may be

limited.

Existing record information showing underground services is often incomplete and of doubtful accuracy. It should be regarded only as

an indication and cannot be guaranteed.

WATER BELOW GROUND

UNKNOWN BELOW GROUND

BT ASSUMED ROUTE

BT BELOW GROUND

ELECTRIC ASSUMED ROUTE

BT ABOVE GROUND

STORM WATER SEWER

ASSUMED COMBINED WATER SEWER ROUTE

UNKNOWN ABOVE GROUND

COMBINED WATER SEWER

ASSUMED FOUL WATER SEWER ROUTE

ELECTRIC ABOVE GROUND

ELECTRIC BELOW GROUND

FOUL WATER SEWER

GAS BELOW GROUND

WATER ASSUMED ROUTE

GAS ASSUMED ROUTE

WATER ABOVE GROUND

COMMS ABOVE GROUND

COMMS BELOW GROUND

SURVEY BOUNDARY

CATV ABOVE GROUND

ASSUMED STORM WATER SEWER ROUTE

CATV BELOW GROUND

REINSTATEMENT SCAR

CATV ASSUMED ROUTE

COMMS ASSUMED ROUTE

GAS ABOVE GROUND

GPR BELOW GROUND

Information to build on

SUITE 5 VITA HOUSE

FISH QUAY

NORTH SHIELDS

NE30 1JA

T: 0191 257 2911

www.sitescanltd.com

TOPOGRAPHICAL SURVEY

TYNE AND WEAR

HEBBURN

CAMPBELL PARK ROAD

GVA

1:250 @ A1 24.02.17

NG

P17042 4/4 A

NR NR

OS

N