kht-09 heat transfer through lagged pipeahlalkawther.com/products/edu/kitek/pdf/kht.pdf · 200mm...
TRANSCRIPT
Heat Transfer Lab
KHT-09 Heat Transfer through Lagged Pipe
compensation. Nichrome Specifications:cartridge heater of • Pipes Length of Pipes – 1m suitable capacity and length.(approx).
• M. S. Pipe inside – 5cm dia. Range of Experiments:
approx, M. S. Pipe Middle – • To determine heat flow rate
10cm dia (approx).through lagged pipe and
• M. S. Pipe Outer – 10cm Control compare it with the heater input
Panel consisting of for known values of thermal
•Voltmeter-0-200 Volts., conductivity of lagging material.
•Ammeter – 0 – 2 Amp.• To determine thermal
•Dimmer stat for heater, conductivity of lagging material
0 - 230 Volts, 2 Amp. by assuming input to be heat
•Digital Temperature indicator, flow rate.
0-300°C using Chromel-• To plot temperature distribution
Allumel thermocouples, across lagging material.
provided with cold junction
KHT-10 Stefan Boltzman Apparatusprovided with cold junction Specifications:compensation.• Hemisphere dia – 200 mm
iii)Built in timer for temperature (approx).readings at 5 seconds • Jacket disc - 250 mm.interval.• Test disc size – 20 mm dia x
1.5mm thickness. Range of Experiments:
• Water tank of sufficient capacity • Determination of Stefan –
with a 1.5 kw immersion heater.Boltzmann constant.
Control Panel comprises of :-• Study of effect of hemisphere
i) Supply for heater.temperature on the constant.
ii) Digital temperature indicator
0-200°C using Chormal-
Alumel thermocouples,
KHT-11 Shell and Tube Heat Exchanger
Specifications:
• Shell - Material -M. S.
-Inner dia -208mm
-Thickness -6mm
-Length -500mm
25% cut baffles at 100mm distance - 4nos.
• Tubes - Material - Copper
- I. D. - 13mm
- O. D. - 16mm
Length of tubes - 500mm
Number of Tubes - 16
• Thermometers- 10-0- to 110°C - 2nos.
• Geysers - 230 V A. C. 3kw. - 1 nos.
Range of Experiments:
• Determination of heat
transfer coefficient for inner
and outer surface of tubes.
• Study of variation of heat
transfer coefficient with
the type of flow.
Kitek Technologies Pvt. Ltd.
Heat Transfer Lab
KHT-12 Parallel Flow and Counter Flow Heat Exchanger
KHT-13 Thermal Conductivity by Guarded Hot Plate
Specifications: Range of Experiments:• Length of Heat Exchange 1.6 m Determination of overall heat
Outer late material G. I. transfer coefficient for a tube –in –
• I. D. – 27.5mm O. D. – 33.8mm tube type heat transfer. To
• Inner tube material – Copper calculate
O.D, 12.7mm i) Rate of heat transfer
• Thermometer 0° to 200°C–1nos. ii) Theoretical overall heat
• Geyser – Instantaneous type. transfer co-efficient.
3kw capacity – 1 no. To compare the performance of
• Measuring flask – 1000 with stop Parallel flow & Counter flow heat
clock. exchanger.
2 Amp – one Specifications:d) Digital Temperature indicator • Central Heater – suitable capacity,
0 - 200°C with using Chromel – with 100 mm dia. sandwiched Allumel thermocouples, between two copper platesprovided with cold junction • 180 mm mica heater Sandwiched compensation.between two copper plates
Cooling chamber with water Range of Experiments:
circulation arrangement.• Determination of Thermal
• Specimen –6 to 20 mm thick, 180 conductivity of insulating
dia.Material in the form of slab.
• Glass wool bag insulation around • Study of variation of Thermal
the set-upConductivity of the material with
• A Control Panel comprising of – temperature.
a) Voltmeter – 0 – 200 Volts• Comparison of Thermal
b) Ammeter – 0 – 2 Ampconductivities of various
c) Dimmer stat for central & insulating Materials.
guard heater 0 – 240 Volts
Specifications: Range of Experiments:• Voltmeter 0 - 200 Volts Two successive regions of pool
• Ammeter 0 - 5 Amp boiling phenomenon namely:
• Cylindrical glass Vessel diameter • Natural Convection Boiling and.
200mm approx. • Nucleate Boiling. Can be
• Cylindrical glass Vessel height visualized up to the critical heat flux
125mm approx. point which is attained by slowly
• Bulk Heater - Nichrome Coil. increasing the input to heater by the
• Test Heater - Nichrome Wire. dimmerstat. At the critical heat flux
• Thermometer - 10° to 100°C. point the wire melts indicating the
maximum heat flux position.
V and I to be recorded at Critical
Heat Flux Point (max.)
KHT-14 Critical Heat Flux Apparatus
Kitek Technologies Pvt. Ltd.
Heat Transfer Lab
KHT-15 Drop and Film Apparatus
KHT-16 Heat Pipe Apparatus
Specifications: Range of Experiments:• Steam generator of suitable • To find out heat transfer co-
capacity. efficient of drop wise and film
• Copper tubes with - wise condensation at various flow
i) Natural finish. rates of water.
ii) Polished surface finish. • Visualization
• Temperature Indicator 0 - 200° C
with Chromel - Alumel
thermocouples.
Specifications:• O. D. of heat pipe = 25mm
• Stainless Steel pipe = 25mm
Copper pipe = 25mm
Length of the pipes = 350 mm each.
• Condenser tank size = 150 x 100 x 100 mm capacity about 2 liter of water.
• Working fluid in heat pipe distilled water.
• Voltmeter 0 - 200 Volts
• Ammeter 0 - 5 Amp
• Dimmerstat 0 - 4 Amp, 0 - 240 Volts.
• Heater-Nichrome heaters with ceramic beads.
• Temperature indicator 0-300°C 18 channels with cold junction
compensation.
• Thermocouples - 6 Nos. on each members. Thermometers - 0° -100°C .1 No.
KHT-17 Unsteady State Apparatus (Plain Tube Pipe)
• A timer with buzzer to note the Specifications: temperature at regular time • Test Piece : interval.Copper Ø25mm X 60L
• The unit provided with an M.S. Ø25mm X 60Lattractive and rust proof powder Brass Ø25mm X 60Lcoating.• Copper test cylinder, with a
thermocouple at the center.
• Water bath with electric heater.
• Dimmer start to control bath
temperature.
• Digital temperature indicator to
measure bath and cylinder
temperature.
Kitek Technologies Pvt. Ltd.
Heat Transfer Lab
KHT-18 Heat Transfer through Mass
KHT-20 Vertical Condenser Test Rig.
Specifications:• Voltmeter 0 - 200 Volts, Ammeter 0 - 5 Amp
• Temperature Indicator 0° - 300°C, Blower - 0.5 HP
• Mass transfer appears in many practical
applications of Chemical & Mechanical
Engineering. Some of examples of industrial
importance of mass transfer are
• Humidify of air in a Cooling Tower
• Evaporation of petrol in the Carburetor of a Petrol
Engine.
• Evaporation of Liquid Ammonia in the
atmospheres of Hydrogen in Electrolux
Refrigerator.
• Dispersion of Oxides of Sulphur from a power
plate discharge of Neutron in a Nuclear Reactor.
KHT-19 Plate Type Heat Exchanger
Optional Accessories (at extra cost)Specifications:• Rotameter to measure water • Heat Exchanger : Plate heat
flow rates instead of measuring exchanger with 5 nos. of 180mm x tank.400mm S. S. plates.
• Multi - channel digital • Geyser to obtain hot water – 3kw temperature indicator 0° - 300° C capacity.to measure the temperatures • Calibrated water flow instead of thermometers.measurement tank.
• Thermometers to measure inlet
and outlet temperatures of fluid.
• Flow control Valves.
A technical manual accompanies
the unit.
Specifications:
• G. I. Shell - 50 NB, 1 m long provided with end
boxes.
• Copper Tube – 21 mm I. D., 25 mm O. D. &
1000 mm length.
• Instantaneous water heater, 3Kw capacity, to
supply hot water
• Temperature indicator for measuring the water
temperatures.
• Valves to control hot and cold water flow.
• Rota meters to measure the cold & hot water flow
rates.
• Voltmeter & ammeter to know the instant supply
conditions.
Kitek Technologies Pvt. Ltd.