ks1000 lp/cr (lo-pitch / curved roof) roof panel (q1 · pdf filemin 2x fixings per crown. 75mm...
TRANSCRIPT
SYSTEM
DESCRIPTION
APPROVED BY
DRG REF:
DATE
SCALE PAPER SIZE
REVISION
SHEET
This document remains the property of Kingspan Ltd under
copyright laws. Licence is granted to use this document and
its contents in connection with Kingspan Ltd products only.
©Kingspan Ltd
DO NOT SCALE. IF IN DOUBT ASK
New Zealand: Kingspan Ltd
97 Montreal St
Christchurch
Tel: +64 (3) 260 5530
Fax: +64 (3) 260 5539
Freephone: 0800 121280
email: [email protected]
www.kingspanpanels.co.nz
APPR
A41 OF 11:5LP_RS_00
111.02.16
DRAWING LIST
KS1000 LP ROOF_STD Q1 2016.DWG
KS1000 LP/CR (Lo-Pitch / Curved Roof) ROOF PANEL (Q1 2016)
DATE DRG TITLE
DRG_REF
REVISION
11.02.16 DRAWING LIST LP_RS_00 1
11.02.16 KS1000 LP PROFILE LP_RS_01 1
11.02.16 KS1000 LP SIDE JOIN & COVER CAP FIXING LOCATIONS LP_RS_02 1
11.02.16 KS1000 LP SIDE JOIN & COVER CAP FIXING LOCATIONS
(HIGH HUMIDITY)
LP_RS_03 1
11.02.16 KS1000 LP END LAP FIXING LOCATIONS LP_RS_04 1
11.02.16 KS1000 LP APEX DAM LP_RS_05 1
11.02.16 KS1000 LP RIDGE DETAIL LP_RS_06 1
11.02.16 KS1000 LP END LAP DETAIL LP_RS_07 1
11.02.16 KS1000 LP EAVES DETAIL LP_RS_08 1
11.02.16 KS1000 LP INTERNAL GUTTER DETAIL LP_RS_09 1
11.02.16 KS1000 LP VALLEY GUTTER LP_RS_10 1
11.02.16 KS1000 LP VERGE DETAIL LP_RS_11 1
11.02.16 KS1000 LP VERGE PARAPET LP_RS_12 1
11.02.16 KS1000 CR CURVED ROOF SETOUT CR_RS_01 1
11.02.16 KS1000 CR END LAP DETAIL CR_RS_02 1
DRAWING LIST
G:\T
echnical\1-current\D
raw
ings\current 2013 Q
1\Lo_pitch R
oof\K
S1000 LP
R
OO
F_S
td Q
1 2016.dw
g, LP
_R
S_00, 8/12/2016 12:39:47 p.m
.
37525152625262525262526252515237 51
NOTE: ABOVE DIMENSIONS ARE THEORETICAL, ACTUAL DIMENSIONS WILL VARY DUE TO
MANUFACTURING TOLERANCES. PRECISE DIMENSIONS MUST ALWAYS BE MEASURED
FROM ACTUAL SAMPLES. ALL DIMENSIONS IN MILLIMETRES.
INSULATION
CORE (A)
OVERALL PANEL
THICKNESS (B)
45
60
80
100
75
90
110
130
1000 COVER WIDTH
AVAILABLE PANEL THICKNESSES
A
B
3
1.5
IN
SU
LA
TIO
N
CO
RE
33.3 33.3
30
7
37
INTERNAL LINER SHEET
EXTERNAL WEATHER SHEET
ANTI CONDENSATION TAPE
(FACTORY APPLIED)
FASTENER
LOCATION
1.5
33.3 33.3
56°
3mm RADIUS
FASTENER
LOCATION
17
ANTI CONDENSATION TAPE
(FACTORY APPLIED)
SYSTEM
DESCRIPTION
APPROVED BY
DRG REF:
DATE
SCALE PAPER SIZE
REVISION
SHEET
This document remains the property of Kingspan Ltd under
copyright laws. Licence is granted to use this document and
its contents in connection with Kingspan Ltd products only.
©Kingspan Ltd
DO NOT SCALE. IF IN DOUBT ASK
New Zealand: Kingspan Ltd
97 Montreal St
Christchurch
Tel: +64 (3) 260 5530
Fax: +64 (3) 260 5539
Freephone: 0800 121280
email: [email protected]
www.kingspanpanels.co.nz
APPR
A41 of 11:5LP_RS_01
111.02.16
KS1000 LP ROOF PANEL DIMENSIONS
KS1000 LP ROOF_STD Q1 2016.DWG
KS1000 LP ROOF PANEL DIMENSIONS
G:\T
echnical\1-current\D
raw
ings\current 2013 Q
1\Lo_pitch R
oof\K
S1000 LP
R
OO
F_S
td Q
1 2016.dw
g, LP
_R
S_01, 8/12/2016 12:39:51 p.m
.
KINGSPAN KS1000 LP LO-PITCH
ROOF PANEL
KINGSPAN KS1000 LP LO-PITCH
COVER CAP WITH FOAM SEALING
STRIP (FACTORY APPLIED)
FOAM SEALING STRIP (FACTORY APPLIED)
PURLIN
MAIN FIXINGS
COVER CAP STITCHING SCREWS OR
SEALED RIVETS AT EAVES AND END LAPS
SYSTEM
DESCRIPTION
APPROVED BY
DRG REF:
DATE
SCALE PAPER SIZE
REVISION
SHEET
This document remains the property of Kingspan Ltd under
copyright laws. Licence is granted to use this document and
its contents in connection with Kingspan Ltd products only.
©Kingspan Ltd
DO NOT SCALE. IF IN DOUBT ASK
New Zealand: Kingspan Ltd
97 Montreal St
Christchurch
Tel: +64 (3) 260 5530
Fax: +64 (3) 260 5539
Freephone: 0800 121280
email: [email protected]
www.kingspanpanels.co.nz
APPR
A41 OF 11:5LP_RS_02
111.02.16
KS1000 LP SIDE JOIN & COVER CAP
FIXING LOCATIONS
KS1000 LP ROOF_STD Q1 2016.DWG
KS1000 LP SIDE JOIN & COVER CAP FIXING LOCATIONS
G:\T
echnical\1-current\D
raw
ings\current 2013 Q
1\Lo_pitch R
oof\K
S1000 LP
R
OO
F_S
td Q
1 2016.dw
g, LP
_R
S_02, 8/12/2016 12:39:52 p.m
.
KINGSPAN KS1000 LP LO-PITCH ROOF PANEL
KINGSPAN KS1000 LP LO-PITCH COVER CAP
WITH FOAM SEALING STRIP (FACTORY APPLIED)
FOAM SEALING STRIP (FACTORY APPLIED)
6mm GUN GRADE SILICONE SEALANT (SITE APPLIED)
TWO CONTINUOUS RUNS OF 6X4 BUTYL SEALING
TAPE. ONE EITHER SIDE OF FIXING TO PREVENT
INGRESS OF MOIST AIR
TWO RUNS OF 6X4 BUTYL SEALING TAPE TO ACROSS
PURLIN PREVENT INGRESS OF MOIST AIR TO FIXING
TIMBER PURLIN
(TYPICAL)
STAINLESS STEEL FIXINGS
COVER CAP STITCHING SCREWS OR
SEALED RIVETS AT EAVES AND END LAPS
SYSTEM
DESCRIPTION
APPROVED BY
DRG REF:
DATE
SCALE PAPER SIZE
REVISION
SHEET
This document remains the property of Kingspan Ltd under
copyright laws. Licence is granted to use this document and
its contents in connection with Kingspan Ltd products only.
©Kingspan Ltd
DO NOT SCALE. IF IN DOUBT ASK
New Zealand: Kingspan Ltd
97 Montreal St
Christchurch
Tel: +64 (3) 260 5530
Fax: +64 (3) 260 5539
Freephone: 0800 121280
email: [email protected]
www.kingspanpanels.co.nz
APPR
A41 OF 11:5LP_RS_03
111.02.16
KS1000 LP SIDE JOIN & COVER CAP FIXING
LOCATIONS (HIGH HUMIDITY)
KS1000 LP ROOF_STD Q1 2016.DWG
KS1000 LP SIDE JOIN & COVER CAP FIXING LOCATIONS
(HIGH HUMIDITY)
G:\T
echnical\1-current\D
raw
ings\current 2013 Q
1\Lo_pitch R
oof\K
S1000 LP
R
OO
F_S
td Q
1 2016.dw
g, LP
_R
S_03, 8/12/2016 12:39:52 p.m
.
FILL GAPS WITH CANISTER FR FOAM FILLER
MP FOAM LP RIDGE FILLER SEALED TOP & BOTTOM
WITH NON-SETTING GUN GRADE SEALANT
0.5MM COIL COATED RIDGE FLASHING WITH
150mm SEALED OVERLAP OR BUTT-STRAPS
CONTINUOUS RUN 6x4 BUTYL SEALANT
COVER CAP
0.5MM COIL COATED INTERNAL RIDGE FLASHING
WITH 150mm SEALED OVERLAP OR BUTT-STRAPS
ALTERNATIVE RIDGE CAP
TURN UP PANEL ENDS.
KINGSPAN KS1000 LP ROOF PANEL
BEAD OF NON SETTING GUN GRADE SEALANT.
SCREW FIX RIDGE FLASHING AT 300mm CTRS
APEX DAM (REF LP_1)
2 RUNS OF NON SETTING GUN GRADE
SEALANT. SCREW FIX IN
PRE-PUNCHED HOLES
BEAD OF NON SETTING
GUN GRADE SEALANT
RIDGE FILLER (REF LP1/F1)
SYSTEM
DESCRIPTION
APPROVED BY
DRG REF:
DATE
SCALE PAPER SIZE
REVISION
SHEET
This document remains the property of Kingspan Ltd under
copyright laws. Licence is granted to use this document and
its contents in connection with Kingspan Ltd products only.
©Kingspan Ltd
DO NOT SCALE. IF IN DOUBT ASK
New Zealand: Kingspan Ltd
97 Montreal St
Christchurch
Tel: +64 (3) 260 5530
Fax: +64 (3) 260 5539
Freephone: 0800 121280
email: [email protected]
www.kingspanpanels.co.nz
APPR
A41 OF 11:5LP_RS_04
111.02.16
KS1000 LP RIDGE DETAIL
KS1000 LP ROOF_STD Q1 2016.DWG
KS1000 LP RIDGE DETAIL
G:\T
echnical\1-current\D
raw
ings\current 2013 Q
1\Lo_pitch R
oof\K
S1000 LP
R
OO
F_S
td Q
1 2016.dw
g, LP
_R
S_04, 8/12/2016 12:39:53 p.m
.
END LAP - FASTENER LOCATIONS (LO-PITCH KS1000 LP)
END LAP - FASTENER LOCATIONS (CURVED ROOF KS1000 CR)
PROFILED FILLER AT RIDGE
TAIL STITCHING PLATE ON
LOWER PANEL
FIX TAIL STITCHING SCREWS FROM THE
CENTRE OUT (MIN 38mm FIXINGS)
123 2 3
TAIL STITCHING PLATE ON
LOWER PANEL
PANEL JOIN
TAIL STITCHING SCREW KS1000 LP
PRIMARY FIXING
LOWER PANEL
UPPER PANEL
KS1000 LP
123 2 3
TAIL STITCHING PLATE
ON LOWER PANEL
PANEL JOIN
TAIL STITCHING SCREWS KS1000 CR
PRIMARY FIXING
LOWER PANEL
UPPER PANEL
KS1000 CR
SYSTEM
DESCRIPTION
APPROVED BY
DRG REF:
DATE
SCALE PAPER SIZE
REVISION
SHEET
This document remains the property of Kingspan Ltd under
copyright laws. Licence is granted to use this document and
its contents in connection with Kingspan Ltd products only.
©Kingspan Ltd
DO NOT SCALE. IF IN DOUBT ASK
New Zealand: Kingspan Ltd
97 Montreal St
Christchurch
Tel: +64 (3) 260 5530
Fax: +64 (3) 260 5539
Freephone: 0800 121280
email: [email protected]
www.kingspanpanels.co.nz
APPR
A41 OF 11:5LP_RS_05
111.02.16
KS1000 LP END LAP FIXING
LOCATIONS
KS1000 LP ROOF_STD Q1 2016.DWG
KS1000 LP END LAP FIXING LOCATIONS
G:\T
echnical\1-current\D
raw
ings\current 2013 Q
1\Lo_pitch R
oof\K
S1000 LP
R
OO
F_S
td Q
1 2016.dw
g, LP
_R
S_05, 8/12/2016 12:39:54 p.m
.
MP FOAM RIDGE FILLER SEALED TOP & BOTTOM
WITH BEAD OF NON-SETTING GUN GRADE SEALANT
2X6mm RUNS NON-SETTING GUN
GRADE SEALANT TO FOLLOW PROFILE
FOLDED STEEL RIDGE DAM
(FROM BELOW)
FOLDED STEEL RIDGE DAM
(FROM ABOVE)
SYSTEM
DESCRIPTION
APPROVED BY
DRG REF:
DATE
SCALE PAPER SIZE
REVISION
SHEET
This document remains the property of Kingspan Ltd under
copyright laws. Licence is granted to use this document and
its contents in connection with Kingspan Ltd products only.
©Kingspan Ltd
DO NOT SCALE. IF IN DOUBT ASK
New Zealand: Kingspan Ltd
97 Montreal St
Christchurch
Tel: +64 (3) 260 5530
Fax: +64 (3) 260 5539
Freephone: 0800 121280
email: [email protected]
www.kingspanpanels.co.nz
APPR
A41 OF 11:1LP_RS_06
111.02.16
KS1000 LP APEX DAM
KS1000 LP ROOF_STD Q1 2016.DWG
CONTINUOUS 10mm RUN
NON-SETTING GUN GRADE BUTYL
SEALANT
10mm RUN NON-SETTING GUN GRADE
SEALANT TO TOP & BOTTOM OF FOAM
FILLER TO FOLLOW PROFILE
KS1000 LP APEX DAM
G:\T
echnical\1-current\D
raw
ings\current 2013 Q
1\Lo_pitch R
oof\K
S1000 LP
R
OO
F_S
td Q
1 2016.dw
g, LP
_R
S_06, 8/12/2016 12:39:54 p.m
.
MIN 2X FIXINGS PER CROWN.
75MM
EN
D LA
P
10 MA
X
25
15
KINGSPAN KS1000 CR (CURVED
ROOF) ROOF PANEL
MIN
IMU
M 300m
m B
ET
WE
EN
PA
NE
L EN
D LA
P A
ND
CO
VE
R C
AP
JOIN
T
COVER CAP COMPLETE WITH
JOGGLE END. FACTORY
APPLIED
CONTINUOUS RUN OF
SILICONE SEALANT
COVER CAP STITCH SCREWED TO LP
PANEL 100mm EITHER SIDE OF LAP JOIN
COVER CAP (STD TO RIDGE)
75mm
JOG
GLE
2 RUNS OF SIKAFLEX SNB MASTIC TO SIDE JOINT
CONTINUOUS BEAD OF SIKAFLEX SNB MASTIC
30MM
MIN
20MM
MIN
FACTORY FITTED END LAP
STITCHING PLATE
18x4mm U SECTION BUTYL RUBBER SEALANT
KS1000 LP (LO-PITCH) PANEL LAP DETAIL.
MIN SLOPE 1.5° AT LAP
END LAP STITCHING SCREW
END LAP - FASTENER LOCATIONS (LO-PITCH KS1000 LP)
TAIL STITCHING PLATE ON
LOWER PANEL
123 2 3
KINGSPAN KS1000 LP/CR COVER
CAP WITH FOAM SEALING STRIP
(FACTORY APPLIED)
PURLIN
MAIN FIXINGS
COVER CAP STITCHING SCREWS
OR SEALED RIVETS AT EAVES
AND COVER CAP END LAPS
2 RUNS OF OF NON-SETTING GUN
GRADE SEALANT TO SIDE JOINT
AT END LAPS
KINGSPAN KS1000 LP
LO-PITCH ROOF PANEL
SYSTEM
DESCRIPTION
APPROVED BY
DRG REF:
DATE
SCALE PAPER SIZE
REVISION
SHEET
This document remains the property of Kingspan Ltd under
copyright laws. Licence is granted to use this document and
its contents in connection with Kingspan Ltd products only.
©Kingspan Ltd
DO NOT SCALE. IF IN DOUBT ASK
New Zealand: Kingspan Ltd
97 Montreal St
Christchurch
Tel: +64 (3) 260 5530
Fax: +64 (3) 260 5539
Freephone: 0800 121280
email: [email protected]
www.kingspanpanels.co.nz
APPR
A41 OF 11:3LP_RS_07
111.02.16
KS1000 LP END LAP DETAIL
KS1000 LP ROOF_STD Q1 2016.DWG
KS1000 LP END LAP DETAIL
G:\T
echnical\1-current\D
raw
ings\current 2013 Q
1\Lo_pitch R
oof\K
S1000 LP
R
OO
F_S
td Q
1 2016.dw
g, LP
_R
S_07, 8/12/2016 12:39:55 p.m
.
FILL GAPS WITH FR FOAM FILLER
SITE APPLIED NON-SETTING GUN GRADE EAVES SEAL
75mm EAVES OVERHANG. TURN DOWN PAN AT EAVES
KINGSPAN KS1000 AWP
PANEL HORIZONTALLY LAID
GUTTER BRACKET ATTACHED TO
FASCIA BOARD FIXED TO EAVES
PURLIN.
PRESSED STEEL GUTTER
INTERNAL FLASHING SEALED WITH 6x4
BUTYL SEALANT. LAP AND SEAL JOINS
TO MAINTAIN CONTINUITY OF SEALANT
KINGSPAN KS1000 LP ROOF
PANEL
COVER CAP STITCH SCREWED TO LP
PANEL 100mm UP FROM EAVES
CUT PANEL. FIXINGS AT 1.0M CTRS
SYSTEM
DESCRIPTION
APPROVED BY
DRG REF:
DATE
SCALE PAPER SIZE
REVISION
SHEET
This document remains the property of Kingspan Ltd under
copyright laws. Licence is granted to use this document and
its contents in connection with Kingspan Ltd products only.
©Kingspan Ltd
DO NOT SCALE. IF IN DOUBT ASK
New Zealand: Kingspan Ltd
97 Montreal St
Christchurch
Tel: +64 (3) 260 5530
Fax: +64 (3) 260 5539
Freephone: 0800 121280
email: [email protected]
www.kingspanpanels.co.nz
APPR
A41 OF 11:5LP_RS_08
111.02.16
KS1000 LP EAVES DETAIL
KS1000 LP ROOF_STD Q1 2016.DWG
KS1000 LP EAVES DETAIL
G:\T
echnical\1-current\D
raw
ings\current 2013 Q
1\Lo_pitch R
oof\K
S1000 LP
R
OO
F_S
td Q
1 2016.dw
g, LP
_R
S_08, 8/12/2016 12:39:56 p.m
.
SITE APPLIED SILICONE EAVES SEAL
FIXING AT CROWN
0.5mm COIL COATED EDGE FLASHING
SEALED WITH 6x4 BUTYL SEALANT
0.5mm COIL COATED
CORNER FLASHING SEALED
WITH 6x4 BUTYL SEALANT
75x125mm X 0.5mm COIL COATED STEEL
TRIM. STAGGER RIVETS AT 200 CTRS.
SEALED WITH 6x4 BUTYL SEALANT
0.9mm GALV. CONTINUOUS STEEL
BRACKET FIXED TO BACK OF GUTTER
WITH 3 NO. 4mm RIVETS @200CRS
ALONG GUTTER
0.5MM COIL COATED EDGE
FLASHING SEALED WITH 6x4
BUTYL SEALANT
INSULATED GUTTER SITE
BUILT BY CONTRACTOR
AIR SEAL 6x4 BUTYL SEALANT
0.9mm GALV. CONTINUOUS STEEL
BRACKET FIXED TO BACK OF GUTTER
WITH 3 NO. 4mm RIVETS @200CRS
ALONG GUTTER
BUTYNOL GUTTER LINING
KS1000 RW PARAPET PANEL
75
GUTTER HIGH POINT
0.5MM COIL COATED CUT
EDGE PROTECTION
FLASHING (IF REQUIRED)
50
75mm EAVES OVERHANG. TURN DOWN PAN AT EAVES
COVER CAP STITCH SCREWED TO LP
PANEL 100mm UP FROM EAVES
AIR SEAL 6x4
BUTYL SEALANT
COVER CAP
5
° M
IN
SYSTEM
DESCRIPTION
APPROVED BY
DRG REF:
DATE
SCALE PAPER SIZE
REVISION
SHEET
This document remains the property of Kingspan Ltd under
copyright laws. Licence is granted to use this document and
its contents in connection with Kingspan Ltd products only.
©Kingspan Ltd
DO NOT SCALE. IF IN DOUBT ASK
New Zealand: Kingspan Ltd
97 Montreal St
Christchurch
Tel: +64 (3) 260 5530
Fax: +64 (3) 260 5539
Freephone: 0800 121280
email: [email protected]
www.kingspanpanels.co.nz
APPR
A41 of 11:5LP_RS_09
111.02.16
KS1000 LP INTERNAL GUTTER DETAIL
KS1000 LP ROOF_STD Q1 2016.DWG
KS1000 LP INTERNAL GUTTER DETAIL
G:\T
echnical\1-current\D
raw
ings\current 2013 Q
1\Lo_pitch R
oof\K
S1000 LP
R
OO
F_S
td Q
1 2016.dw
g, LP
_R
S_09, 8/12/2016 12:39:56 p.m
.
SITE APPLIED NON-SETTING
GUN GRADE EAVES SEAL
FIXING AT CROWN
0.5mm COIL COATED
CORNER FLASHING SEALED
WITH 6x4 BUTYL SEALANT
75x125mm X 0.5mm COIL COATED STEEL
TRIM. STAGGER RIVETS AT 200 CTRS.
SEALED WITH 6x4 BUTYL SEALANT
0.9mm GALV. CONTINUOUS STEEL
BRACKET FIXED TO BACK OF GUTTER
WITH 3 NO. 4mm RIVETS @200CRS
ALONG GUTTER
0.5mm COIL COATED EDGE
FLASHING SEALED WITH 6x4
BUTYL SEALANT
MIN 50mm THICK INSULATED GUTTER
SITE BUILT BY CONTRACTOR
AIR SEAL 6x4 BUTYL SEALANT
BUTYNOL GUTTER LINING
75
GUTTER HIGH POINT
75
SITE CUT-BACK (RAKED)
75mm EAVES OVERHANG.
TURN DOWN PAN AT EAVES
COVER CAP STITCH SCREWED TO
LP PANEL 100mm UP FROM EAVES
COVER
CAP
SYSTEM
DESCRIPTION
APPROVED BY
DRG REF:
DATE
SCALE PAPER SIZE
REVISION
SHEET
This document remains the property of Kingspan Ltd under
copyright laws. Licence is granted to use this document and
its contents in connection with Kingspan Ltd products only.
©Kingspan Ltd
DO NOT SCALE. IF IN DOUBT ASK
New Zealand: Kingspan Ltd
97 Montreal St
Christchurch
Tel: +64 (3) 260 5530
Fax: +64 (3) 260 5539
Freephone: 0800 121280
email: [email protected]
www.kingspanpanels.co.nz
APPR
A41 OF 11:5LP_RS_10
111.02.16
KS1000 LP VALLEY GUTTER
KS1000 LP ROOF_STD Q1 2016.DWG
KS1000 LP VALLEY GUTTER
G:\T
echnical\1-current\D
raw
ings\current 2013 Q
1\Lo_pitch R
oof\K
S1000 LP
R
OO
F_S
td Q
1 2016.dw
g, LP
_R
S_10, 8/12/2016 12:39:57 p.m
.
"Z" FLASHING WITH CONTINUOUS RUNS
OF 20x3mm BUTYL SEALANT
0.5mm COIL COATED VERGE FLASHING WITH 150mm
SEALED OVERLAP OR BUTT-STRAPS. SEALED TO
WALL PANEL WITH 6x4 BUTYL SEALANT
DIRECTION
OF LAY
FILL GAPS WITH FR FOAM FILLER
KS1000 LP/CR INSULATED
ROOF PANEL
KS1000 LP ROOF VERGE DETAIL
(FACTORY EDGE)
GALV CLEADER ANGLE BY STEEL CONTRACTOR. AIR
SEAL WITH 6x4mm BUTYL SEALANT. BUTT STRAPS
AT JOINS TO MAINTAIN CONTINUITY OF SEALANT
"Z" FLASHING WITH CONTINUOUS RUNS OF
20x3mm BUTYL SEALANT
0.5mm COIL COATED VERGE FLASHING WITH 150mm
SEALED OVERLAP OR BUTT-STRAPS. SEALED TO
WALL PANEL WITH 6x4 BUTYL SEALANT
DIRECTION
OF LAY
FILL GAPS WITH FR FOAM FILLER
KS1000 LP/CR INSULATED ROOF
PANEL
KS1000 LP ROOF VERGE DETAIL
(SITE CUT)
GALV CLEADER ANGLE BY STEEL CONTRACTOR. AIR
SEAL WITH 6x4mm BUTYL SEALANT. BUTT STRAPS AT
JOINS TO MAINTAIN CONTINUITY OF SEALANT
TURN UP SITE CUT EDGE OF PANEL 30mm
SYSTEM
DESCRIPTION
APPROVED BY
DRG REF:
DATE
SCALE PAPER SIZE
REVISION
SHEET
This document remains the property of Kingspan Ltd under
copyright laws. Licence is granted to use this document and
its contents in connection with Kingspan Ltd products only.
©Kingspan Ltd
DO NOT SCALE. IF IN DOUBT ASK
New Zealand: Kingspan Ltd
97 Montreal St
Christchurch
Tel: +64 (3) 260 5530
Fax: +64 (3) 260 5539
Freephone: 0800 121280
email: [email protected]
www.kingspanpanels.co.nz
APPR
A41 OF 11:5LP_RS_11
111.02.16
KS1000 LP VERGE DETAIL
KS1000 LP ROOF_STD Q1 2016.DWG
KS1000 LP VERGE DETAIL
G:\T
echnical\1-current\D
raw
ings\current 2013 Q
1\Lo_pitch R
oof\K
S1000 LP
R
OO
F_S
td Q
1 2016.dw
g, LP
_R
S_11, 8/12/2016 12:39:57 p.m
.
KINGSPAN KS1000 LP
ROOFING PANEL
CONTINUOUS RUN OF 6x4 BUTYL SEALANT. LAP
FLASHINGS TO MAINTAIN CONTINUITY OF AIR SEAL
INTERNAL CLOSER FLASHING
"Z" FLASHING WITH CONTINUOUS RUNS
OF 20x3mm BUTYL SEALANT
FILL GAPS WITH FR FOAM FILLER
0.5mm COIL COATED PARAPET
FLASHING SEALED WITH CONTINUOUS
RUN OF 6x4mm BUTYL SEALANT
INFILL
BLOCK
CUT PANEL - FIXINGS
AT 1.0m CTRS
AWP PANEL BEARER
SYSTEM
DESCRIPTION
APPROVED BY
DRG REF:
DATE
SCALE PAPER SIZE
REVISION
SHEET
This document remains the property of Kingspan Ltd under
copyright laws. Licence is granted to use this document and
its contents in connection with Kingspan Ltd products only.
©Kingspan Ltd
DO NOT SCALE. IF IN DOUBT ASK
New Zealand: Kingspan Ltd
97 Montreal St
Christchurch
Tel: +64 (3) 260 5530
Fax: +64 (3) 260 5539
Freephone: 0800 121280
email: [email protected]
www.kingspanpanels.co.nz
APPR
A41 OF 11:5LP_RS_12
111.02.16
KS1000 LP VERGE PARAPET
KS1000 LP ROOF_STD Q1 2016.DWG
KS1000 LP VERGE PARAPET
G:\T
echnical\1-current\D
raw
ings\current 2013 Q
1\Lo_pitch R
oof\K
S1000 LP
R
OO
F_S
td Q
1 2016.dw
g, LP
_R
S_12, 8/12/2016 12:39:58 p.m
.
BUILDING WIDTH BETWEEN 70 & 100M TYPICAL
LAP ANGLE MIN 1.5° AFTER DEFLECTIONS
PANEL 1
(EAVES)
PANEL 2
(CROWN)
PANEL 3
(EAVES)
KS1000 CR - CURVED ROOF PANEL LAYOUT SEQUENCE
PURLIN SPACING 1800MM MAX
CURVED ROOF: MIN 150M RADIUS
END LAP - FASTENER LOCATIONS (CURVED ROOF KS1000 CR)
FIX TAIL STITCHING SCREWS FROM THE
CENTRE OUT (MIN 38mm FIXINGS)
SYSTEM
DESCRIPTION
APPROVED BY
DRG REF:
DATE
SCALE PAPER SIZE
REVISION
SHEET
This document remains the property of Kingspan Ltd under
copyright laws. Licence is granted to use this document and
its contents in connection with Kingspan Ltd products only.
©Kingspan Ltd
DO NOT SCALE. IF IN DOUBT ASK
New Zealand: Kingspan Ltd
97 Montreal St
Christchurch
Tel: +64 (3) 260 5530
Fax: +64 (3) 260 5539
Freephone: 0800 121280
email: [email protected]
www.kingspanpanels.co.nz
APPR
A41 OF 1NTSCR_RS_01
111.02.16
KS1000 CR CURVED ROOF SETOUT
KS1000 LP ROOF_STD Q1 2016.DWG
KS1000 CR CURVED ROOF SETOUT
G:\T
echnical\1-current\D
raw
ings\current 2013 Q
1\Lo_pitch R
oof\K
S1000 LP
R
OO
F_S
td Q
1 2016.dw
g, C
R_R
S_01, 8/12/2016 12:39:59 p.m
.
MIN 2X FIXINGS PER CROWN.
75MM
EN
D LA
P
10 MA
X
25
15
END LAP STITCHING SCREW
FACTORY FITTED END LAP STITCHING PLATE
18x4mm U SECTION BUTYL RUBBER SEALANT
KINGSPAN KS1000 CR (CURVED
ROOF) ROOF PANEL
MIN
IMU
M 300m
m B
ET
WE
EN
PA
NE
L EN
D LA
P A
ND
CO
VE
R C
AP
JOIN
T
COVER CAP COMPLETE WITH
JOGGLE END. FACTORY
APPLIED
CONTINUOUS RUN OF
SILICONE SEALANT
COVER CAP STITCH SCREWED TO LP
PANEL 100mm EITHER SIDE OF LAP JOIN
COVER CAP (STD TO RIDGE)
75mm
JOG
GLE
75MM
2 RUNS OF NON-SETTING GUN GRADE SEALANT
TO SIDE JOINT
CONTINUOUS BEAD OF SIKAFLEX SNB MASTIC
75MM
1.5mm GALV CURVED ROOF
SUPPORT CLOSURE PLATE (LP2)
END LAP - FASTENER LOCATIONS (CURVED ROOF KS1000 CR)
FIX TAIL STITCHING SCREWS FROM THE
CENTRE OUT (MIN 38mm FIXINGS)
KINGSPAN KS1000 LP/CR COVER
CAP WITH FOAM SEALING STRIP
(FACTORY APPLIED)
PURLIN
MAIN FIXINGS
COVER CAP STITCHING SCREWS
OR SEALED RIVETS AT EAVES
AND COVER CAP END LAPS
2 RUNS OF OF NON-SETTING GUN
GRADE SEALANT TO SIDE JOINT
AT END LAPS
KINGSPAN KS1000 LP
LO-PITCH ROOF PANEL
SYSTEM
DESCRIPTION
APPROVED BY
DRG REF:
DATE
SCALE PAPER SIZE
REVISION
SHEET
This document remains the property of Kingspan Ltd under
copyright laws. Licence is granted to use this document and
its contents in connection with Kingspan Ltd products only.
©Kingspan Ltd
DO NOT SCALE. IF IN DOUBT ASK
New Zealand: Kingspan Ltd
97 Montreal St
Christchurch
Tel: +64 (3) 260 5530
Fax: +64 (3) 260 5539
Freephone: 0800 121280
email: [email protected]
www.kingspanpanels.co.nz
APPR
A41 OF 11:3CR_RS_02
111.02.16
KS1000 CR (CURVED ROOF) PANEL
LAP DETAIL. MIN SLOPE 1.5° AT LAP
KS1000 LP ROOF_STD Q1 2016.DWG
KS1000 CR (CURVED ROOF) PANEL LAP
DETAIL. MIN SLOPE 1.5° AT LAP
G:\T
echnical\1-current\D
raw
ings\current 2013 Q
1\Lo_pitch R
oof\K
S1000 LP
R
OO
F_S
td Q
1 2016.dw
g, C
R_R
S_02, 8/12/2016 12:39:59 p.m
.