LG Air Conditioner Technical Solutions (LATS) Multi V Model Selection Program User Guide

Ver 1.7.11.26

Page 2: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS User Guide

Table of Contents

1. LATS OVERVIEW 4

LATS Introduction .................................................................. 4

LATS Multi V Model Selection Program ........................................ 5

System Requirements for LATS ................................................. 6

2. LATS MULTI V MODEL SELECTION PROGRAM 7

Introduction ....................................................................... 7

Installation ......................................................................... 9

Usage Description : Tree Mode .............................................. 11

■ Step 1. Create Project ························································ 12

■ Step 2. Select Model ··························································· 23

■ Step 3. Modify the length of pipe arrangement ·························· 29

■ Step 4. Check System ························································· 30

■ Step 5. Write the report ······················································ 32

Usage Description : CAD Mode ............................................... 39

■ Step 1. Create Project ························································ 40

■ Step 2. Select Model ··························································· 48

■ Step 3. Draw System and Design Piping ···································· 59

■ Step 4. Check System ························································· 70

Page 3: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Overview

■ Step 5. Write the report ······················································ 73

3. TIPS FOR USING MULTI V MODEL SELECTION PROGRAM 74

Set Scale in Multi V Model selection program ............................ 74

Assign one load for one indoor unit in Multi V Model selection program75

Draw orthogonal pipes in Multi V Model selection program .......... 76

4. CONTACT INFORMATION 78

Page 4: Lats-Multi v-Multi v Model Selection[20071204093730603]

1. LATS Overview

LATS Introduction

LATS Multi V Model Selection Program

System Requirements for LATS

LATS (LG Air Conditioner Technical Solution) program is a total design solution for LG system air conditioners. It consists of load calculation program and model selection program for system air conditioners. Load calculation program and model selection program can be selectively used. Although users use different load calculation program other than LATS, they can use LATS model selection program.

Note : System air conditioners mean the devices that can operate multiple indoor units

with one outdoor unit. It is referred as system air conditioners or multi v air

conditioners. Each indoor unit can be operated separately and independently.

Note : LG provides various technical data like products, architecture information,

maintenance information, etc by the homepage, www.lgeaircon.com. LATS programs and user guides are automatically updated on this site.

LATS Introduction

Page 5: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Overview

5

LATS Multi V Model Selection program selects the specific model for system air conditioners. It can select products, pipe arrangements, electric design by using AutoCAD. This program is classified as Tree Mode and Cad Mode. For simple piping work, Tree Mode is used. Users can select models even they do not have CAD drawings for building, because they have Tree Mode in a program.

LATS Multi V Model Selection Program

Note : LATS provides auto update feature. When users start LATS program, an auto

update notification message appears to guide you a new version of a program.

Page 6: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Overview

6

This is the hardware requirements for using LATS.

Item Description

CPU Intel PII,500MHz

Chip Set Intel

Main Memory 128 MB

Disk capacity/speed > 40 GB / 5400rpm / < 15ms access

Graphics Integrated / PCI based

Audio Integrated / PCI based

This is the software requirements for using LATS.

Item Description

OS Windows 98 SE, Windows NT, Windows XP & Windows 2000

Web Browser Above Internet Expiorer 5.0

Application Software MS Excel, MS Access

Caution:

To get an output as a report form, Micosoft Excel program should be installed on users’ computers before they use LATS program.

System Requirements for LATS

Page 7: Lats-Multi v-Multi v Model Selection[20071204093730603]

2. LATS Multi V Model Selection Program

Introduction

Installation

Usage Description

LATS Multi V Model Selection program can be operated in two types of modes. Tree Mode is displayed as a tree form, for a simple piping work. When there is no CAD drawing for a building, this program can provide the proper quantity of indoor/outdoor air conditioners, cutoff, additional refrigerant amounts, etc. However, sometimes users should rearrange the drawing to be transformed by CAD. To do so, users should manage the drawing work on CAD Mode at first.

1. Create Project

Enter the location information and design condition. Psychrometric chart automatically calculates a dry bulb temperature, wet bulb temperature, and relative humidity of current air. Then load information related to cooling and heating is entered. If users have already used LATS Load program, the result value can be simply loaded by a button. It there is no result, users can manually insert the cooling and heating load as a KW unit.

2. Select Model

Outdoor unit automatically sets its entire heat load value. Proper indoor units for each room can be selected by dragging indoor icon or double clicking the box. After indoor air conditioners are chosen, outdoor air conditioners can be chosen by double clicking the outdoor unit icon. Basically, Auto Select Mode is recommended for this.

Caution:

Drawings that were managed at CAD Mode at first can be transformed into Tree Mode. However, the drawings that were managed at Tree Mode at first cannot be transformed into CAD Mode. In this case, users should select new CAD Mode to design the piping work. The file that is designed at CAD Mode can be outputted as .dxf file. It can be opend and edited in AutoCAD.

Introduction

Page 8: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

3. Modify the length of pipe arrangement

Users should modify the default length of pipe into an actual length. Users can directly insert the length by double clicking the line. Elbow or curve line should be considered. Combination rate and total length can be checked at any time during the design. After this work is completed, Auto Piping button should be clicked. A meesage that tells the success of auto selection feature appears.

The size of pipe and model name of branch are automatically decided based on EPDB (Engineering Product Data Book) data that http://www.lgeaircon.com provides. EPDB is a PDF file that contains the specification information, piping information, etc of products.

4. Check System

Click System Check button to check the entire system including model selection, piping work, validation, cooling/heating simulation, etc. Schematic Diagram provides the wire connection picture of indoor/outdoor air conditioners. The quantity of an additional refrigerants that users should install according to the quantity and information for cutoff devices on electric leakage is calculated automatically.

5. Write the report

The result is outputted as a Microsoft Excel file. Comments, customer information, title, table of contents, system selection, product lists, piping drawings, wire connection picture, etc are covered. For a written estimate, the product price and installation cost can be inserted by vendors.

Note:

Tree Mode is based on a system, while CAD Mode is based on a floor. One system matches with one outdoor unit. Tree mode has one outdoor unit and its related hierarchy.

Page 9: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

1. Access www.lgeaircon.com to download LATS-Multi V program. Execute the LATS-Multi V program on your local computer. InstallShield Wizard for LATS-MultiV appears. Click Next.

2. License Agreement window appears. Read it carefully and click Yes. .

Installation

Page 10: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

10

3. Customer Information window appears. Enter your User Name and Company

Name. For Serial Number, enter latsmultiv. Then click Next.

4. Installation is completed. Click Finish.

Page 11: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

11

LATS Multi V Model Selection program can be operated in two types of modes. Tree Mode is displayed as a tree form, for a simple piping work. When there is no CAD drawings for a building, this program can provide the proper quantity of indoor/outdoor air conditioners, cutoff, additional refrigerants, etc. However, sometimes users should rearrange the drawing to be transformed by CAD. For CAD Mode, users can manage the drawing work on CAD at first. Following introduces how to use LATS Multi V Model selection program in Tree Mode. This is the main flow of using LATS Multi V model selection program.

Usage Description : Tree Mode

Page 12: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

12

1. Click icon or click “Start Programs LGE ” LATS-MultiV” to run LATS Multi v model selection program. Then the program runs and this screen shot appears.

This is the initial screen display of LATS Multi v model selection program. Following explains each menu and button.

Menu

File

Menu Description

New Project This menu creates a new project.

Open Project This menu opens a project that users select.

Close Project This menu closes a project. If you want to open a new project, you should close the previous one first.

View Project This menu shows a project.

■ Step 1. Create Project

1

2

3

1

1

2

3

Page 13: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

13

Save Project This menu saves a project.

Save Project As This menu saves a project as a specific name.

Delete Project This menu deletes a project

Export This menu exports a project as a GCSI file.

Exit This menu closes a project and finishes a program.

System

Menu Description

Create System This menu creates a system.

Copy System This menu copies a system.

Delete System This menu deletes a system.

System setting This menu sets a system.

Space Load Summary This menu shows a space load summary.

Auto Piping This menu automatically selects Y branch, header and pipe diameter automatically.

System check System Check supports validation check and performance simulation.

- Validation check : It check total piping length, longest pipe length after 1st branch, each pipe length and all the validation in PDB.

- Performance simulation : It simulates system’s performance from combination, design condition, pipe length and defrosting factor.

System Invalidation property This menu checks the proper connectivity and number of included sub items.

Generate reports This menu generates the final report as a Micosoft excel file.

Page 14: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

14

View

Menu Description

Tool Bar This menu shows Tool bar on your program display.

Status Bar This menu shows Status bar on your program display.

System Log Viewer This menu positions a window on your program display that shows a system log.

Project Navigator This menu shows the left panel on your program display. You can control the size of this part with and closes this part with .

System View This menu shows System panel, Indoor Units List and

System Information.

Schematic Diagram This menu shows a hierarchical diagram among outdoor unit, indoor unit, brances and pipes.

System preview This menu shows a current system in a full view to help users watch the entire system easily.

Option This menu sets the term of project auto save period. Selected box size is also set at CAD Option.

Page 15: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

15

Language

Menu Description

English This menu shows the current display in English.

Korean This menu shows the current display in Korean.

Spanish This menu shows the current display in Spanish.

French This menu shows the current display in French.

German This menu shows the current display in German.

Italian This menu shows the current display in Italian.

User Setting Users can set their own language that is provided at the above menu.

Help

Menu Description

LATS Help This menu shows the help contents for LATS.

About LATS This menu shows the version and information of LATS.

View Update Info This menu shows the updated information of view.

LATS-Multi V

Menu Description

Project Information This menu shows project information.

Model Selection This menu is selected when users select models in a program.

Generate Report This menu generates final report that is created after users use LATS-Multi V program.

2 fg

Page 16: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

16

Project

Menu Description

Create Project This menu creates a new project.

View Project Info This menu shows a project information.

Open Project This menu opens a popup window to select a project to open, which is already made.

Delete Project This menu deletes a project.

Close Project This menu closes a project. If you want to open a new project, you should close the current one first.

2. Press Create Project button to see this window.

Date that the project is created

Project Name

Path of the project to save it

3

fg 4

fg

5

1

tha

t th

e

proje

ct

is

create

d

Path

of

the

pr

oje

ct to

sav

e it

Pr

2 tha

t

the

pr

oje

ct is

cre

ated

Pat

h

of th

e

proje

ct

to sav

e

it

1

tha

t th

e

pr

oject

is

cre

2

that

th

e pr

oje

ct

3

fg

6

7

3 fg

Page 17: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

17

Project Unit

SI/IP:

For heat load calculation unit, LATS includes SI, which is an international standard and IP, which is an English standard. US and middle east use IP while Europe uses SI. Some countries use IP for quantity and SI for length. This kind of mixed usage is also possible.

Simulation Mode:

Users select Cooling mode to make their projects based on cooling operation. In this case, the usage is focused on cooling. Users select Heating mode to make their projects based on heating operation. In this case, the usage is focused on heating.

Outdoor Unit Type

Users can decide the outdoor unit type that they want from the drop down button.

Detailed Comments for the project

Users enter their detailed comments on this blank. Users check the checkbox of Use CAD to use CAD Mode.

Direction button

User can move next step.

Note :

<Tree mode> <CAD mode>

Tree mode shows the design as a tree shape.

Cad mode shows the design on an existing CAD drawuing.

Output can be transformed as a DXF file and opened at Auto CAD to be editted.

4 fg

6

5

7

Page 18: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

18

From this Create Project window, enter the project information. Then click Next.

- Date that the project is created

- Project Name

- Path of the project to save it

- Project Unit

- Simulatino Mode

- Outdoor Unit Type

- Detailed Comments for the project

3. Select country and city. Then input design condition.

Change the design condition if the given values do not satisfy your requirements.

If you change one of the following air property (DBT,WBT,RH), psychometric process will be executed. Other related values will be found.

Click Next.

Insert the country, State/Province and City information.

Dry bulb temperature, Wet bulb temperature and Relative humidity should be inserted. This information should be inserted for each indoor and outdoor also in Cooling and Heating condition.

Caution:

Be sure to active Use CAD option if you are using CAD drawing for model selection. To Use Tree mode, do not check it.

1

tha

t th

e

pr

oject

is

create

d

Path

of

th

e pr

oje

ct to

sav

e

it Pr

oje

ct Na

me

Pr

2

tha

t th

e

proje

ct

is cre

ate

d

Path

of

the

pr

oje

ct to

sav

e it

1 tha

t

th

e pr

oje

ct is

cre

ated

Pat

h

2

tha

t th

e

pr

oject

is

create

d

Pat

Page 19: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

19

4. When selecting Open Load, you can load the result calculated by LATS-LOAD. Clik Open load button.

- Open load

You can open the load information that was previously calculated by LATS Load program.

- Add floor/Add space

If you do not use the previously calculated value of LATS Load program, you can manually insert the floor information with this button.

- Remove row, Remove all

These row buttons are activated only when floors are added manually in advance. This button removes the currently added row or removes all rows. After you complete your setting, click Next.

5. From this window you can select the pre-calculated heat load of Load program. Select one and click OK.

Page 20: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

20

6. The pre-calculated information is displayed as follows.

If you do not have the pre-defined value, click Add floor or Add space to add a new row. To remove it, click Remove all button. If LATS LOAD values are not available, manual load entry can also be done simply by adding values in columns

Click Next.

7. Input Customer & contractor Information. It will be printed out on your final report. After filling all data, click Finish.

Then model selection window appears.

Page 21: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

21

This is the initial display of Tree mode. Following is a description for menus and icons.

Page 22: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

22

Icon Description

Save project, Ctrl + S

System setting, Ctrl + 4

New system, Ctrl + 1

Copy system, Ctrl + 2

Delete system, Ctrl + 3

Auto piping sets the pipe arrangement automatically. F5

System Check checks if the current system is available to be installed and designed. F6

System Validation property checks if the outdoor unit, indoor unit and brances has proper relation and hierarchy. F7

Toggle description

System load summary sees the system load entirely. Ctrl + 5

View reports, F8

System preview

Open/Close, Toggle Navigator, Ctrl + P

System panel that shows a window that you work on currently

Control line

Power cable

Pipe line

Page 23: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

23

From this window, you can start selecting outdoor units, indoor units, branch pipes and header pipes according to our design. Initial window for Multi V program looks like this.

1. Double click on stand-by box. Then this window appears. Choose the type of equipments that you want and click

OK.

Following is a description for these types.

Menu Description

Indoor Units Indoor Units

Y branch This equipment is used for large volume of systems. Pipe can have two brances. Numbers are set before a specific model name is assigned. Specific model is assigned after auto piping.

4 header Pipe has 4 branches.

7 header Pipe has 7 branches.

10 header Pipe has 10 branches. Header is rarely used because of the difficulty in installation. This is used for small volume system.

2. If you choose Indoor Unit, this window appears to view the detailed information. Then click

OK.

Following is an example of choosing an indoor unit and 4 header.

■ Step 2. Select Model

Page 24: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

24

At this display, select equipment and design pipes. By simply double clicking an item, you can add or modify the hierarchy of the system.

Page 25: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

25

3. At this screen, if you double click Outdoor unit, Y-Branch or indoor unit, a window that displays detailed information of an item is shown. Following is an example of the result after you double click Y-Branch. After viewing it, click OK.

4. Double click room to assign load. This window appears.

Select room load and click OK. Then room load is assigned.

Page 26: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

26

Then as you see below, the room that you double clicked turned to have Floor-001(room1) information. Like this, choose other rooms to assign heat load.

Page 27: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

27

5. Double click Indoor Unit or Drag & Drop Indoor Unit from Toolbar to select indoor unit. This popup window appears.

Check the ratio (IDU capacity over Design load). If you want to select accessory, click accessory button.

Like this, finish assigning undoor unit selection. Then click OK.

6. Double click Outdoor unit icon after finishing indoor units selection.

Outdoor unit window appears. Outdoor unit information supports these types:.

- Search Model : It lists models according to a category.

- Full Model : It lists all models in same ODU type.

- Auto Selection : It lists the supporting model to designed system. (below 100% combination)

We recommend you using auto selection. If you use defrosting factor, check Defrosting factor

Page 28: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

28

Then as you see below, the outdoor unit icon has its model name.

Page 29: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

29

1. If you want to change pipe length, double click pipe length value. This window

appear. Change pipe length as you want. Pipe length should be the equivalent length.

You have to check system property window which is notified at the next window. (Combination, total pipe length)

2. Click Auto Piping button at the left part of initial window, to select Y branch, Header and pipe diameter automatically.

Firstly, pipe’s diameter will be decided according to pipe length that is after 1st branch and capadity of indoor units, and then Auto piping will select a appreciate branch models or Header models

More detailed information, limitation and rules are documented in PDB.

3. This window appears to confirm your selection. Click OK.

If any problem is not occurred, All branch and header models are selected automatically. If Y branch or Header do not exists, you have to change pipe design or check branch or header in PDB

■ Step 3. Modify the length of pipe arrangement

Page 30: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

30

1. Click System Check to simulate the system. System Check supports

validation check and performance simulation.

Menu Description

Validation check It checks total piping length, the longest pipe length after 1st branch, each pipe length and all validation in PDB. It checks the combination ratio, which should be within 50 ~ 130%. The indoor unit and outdoor unit should be maximum 130 percentage. (if Model type is PLUS II, Any model can be combinated by 200%)

(PLUS I) If the position of outdoor unit is higher than indoor unit, it can be maximum 40 meters. For the opposite case, it should be 50 meters.

(PLUS II) If the position of outdoor unit is higher than indoor unit, it can be maximum 100 meters. For the opposite case, it should be 100 meters.

More detailed information, limitation and rules are documented in EPDB.

Performance simulation It simulates system’s performance from combination, design condition, pipe length and defrosting factor.

Each indoor unit capacity is simulated and changed. After system is checked, this window appears. Click OK.

Caution:

* We can guarantee the operatoin only within 130% Combination. (PLUS II Models only)

If you want to connect more than 130% combination, please contact us and discuss the requirement like below.

1) If the operation of indoor unit is more than 130%, low airflow operation is recommended in all the indoor units.

2) If the operation of indoor unit is more than 130%, additional refrigerant is needed according to the headquarter guidance.

■ Step 4. Check System

Page 31: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

31

2. Press Schematic Diagram button to see this display.

Check Additional refrigerant amounts and Wiring design. If you want to go back to Tree mode, you can press Tree button of the left part of initial window.

Page 32: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

32

1. Click Generate Report on the left part of initial window. Select the sheet of reports to make. Then click OK.

■ Step 5. Write the report

Page 33: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

33

These are the examples of final report.

This is the cover of final report.

Page 34: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

34

This is the air conditioning proposal. It covers the proposal This is the table of contents.

information and costs including installation, accessories, etc.

Page 35: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

35

This is the load output. It contains building location, design conditions, This is the model selection summary. Outdoor units, Indoor units, pipes and

cooling and heating loads, etc. accessories are included.

Page 36: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

36

This is the result of system check. It includes design condition, outdoor/indoor information, pipes, etc.

Page 37: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

37

This is the pipe design tree illustration and schematic diagram for electric wires.

Page 38: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

38

This is the model selection cost analysis sheet. It totally covers outdoor units, indoor units, pipes and branch/header common pipes.

This document can be used as an estimation sheet.

Page 39: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

39

LATS Multi V Model Selection program can be operated in two types of modes. Tree Mode is displayed as a tree form, for a simple piping work. When there is no CAD drawings for a building, this program can provide the proper quantity of indoor/outdoor air conditioners, cutoff, additional refrigerants, etc. However, sometimes users should rearrange the drawing to be transformed by CAD. For CAD Mode, users can manage the drawing work on CAD at first. Following introduces how to use LATS Multi V Model selection program in CAD mode. This is the main flow of using LATS Multi V model selection program.

Usage Description : CAD Mode

Page 40: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

40

1. Click icon or click “Start Programs LGE ” LATS-MultiV” to run LATS Multi V model selection program. Then the program runs and this screen shot appears.

This is the initial screen display of LATS Multi V model selection program. Following explains each menu and button.

Menu

File

Menu Description

New Project This menu creates a new project.

Open Project This menu opens a project that users select.

Close Project This menu closes a project. If you want to open a new project, you should close the previous one first.

View Project This menu shows a project.

Save Project This menu saves a project.

■ Step 1. Create Project

1

2

3

1

1

2

3

Page 41: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

41

Save Project As This menu saves a project as a specific name.

Delete Project This menu deletes a project

Export This menu exports a project as a GCSI file.

Exit This menu closes a project and finishes a program.

System

Menu Description

Create System This menu creates a system.

Copy System This menu copies a system.

Delete System This menu deletes a system.

System setting This menu sets a system.

Space Load Summary This menu shows a space load summary.

Auto Piping This menu automatically selects Y branch, header and pipe diameter automatically.

System check System Check supports validation check and performance simulation.

- Validation check : It checks total piping length, the longest pipe length after 1st branch, each pipe length and all validation in PDB.

- Performance simulation : It simulates system’s performance from combination, design condition, pipe length and defrosting factor.

System Invalidation property This menu checks the proper connectivity and number of included sub items.

Generate reports This menu generates the final report as a Micosoft excel file.

Page 42: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

42

View

Menu Description

Tool Bar This menu shows Tool bar on your program display.

Status Bar This menu shows Status bar on your program display.

System Log Viewer This menu positions a window on your program display that shows a system log.

Project Navigator This menu shows the left panel on your program display. You can control the size of this part with and closes his part with .

System View This menu shows System panel, Indoor Units List and

System Information.

Schematic Diagram This menu shows a hierarchical diagram among outdoor unit, indoor unit, brances and pipes.

System preview This menu shows a current system in a full view to help users watch the entire system easily.

Option This menu sets the term of project auto save period. Selected box size is also set at CAD Option.

Page 43: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

43

Language

Menu Description

English This menu shows the current display in English.

Korean This menu shows the current display in Korean.

Spanish This menu shows the current display in Spanish.

French This menu shows the current display in French.

German This menu shows the current display in German.

Italian This menu shows the current display in Italian.

User Setting Users can set their own language that is provided at the above menu.

Help

Menu Description

LATS Help This menu shows the help contents for LATS.

About LATS This menu shows the version and information of LATS.

View Update Info This menu shows the updated information of view.

LATS-Multi V

Menu Description

Project Information This menu shows project information.

Model Selection This menu is selected when users select models in a program.

Generate Report This menu generates final report that is created after users use LATS-Multi V program.

2 fg

Page 44: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

44

Project

Menu Description

Create Project This menu create a new project.

View Project Info This menu shows a project information.

Open Project This menu opens a popup window to select a project to open, which is already made.

Delete Project This menu deletes a project.

Close Project This menu closes a project. If you want to open a new project, you have to close the previous one first.

2. Press Create Project button to see this window.

Date that the project is created

Project Name

Path of the project to save it

Project Unit

3 fg

3

fg 4

fg

5

1

that

th

e pr

oje

ct is

cre

ate

d Pat

h

of th

e

pr

oject

to

save

it

Proje

2

tha

t th

e

pr

oject

is

create

d

Path

of

th

e pr

oje

ct to

sav

e it

Pr

1

that

th

e pr

oje

ct

is cre

ate

2

tha

t th

e

pr

oject

is

cre

3

fg 4

fg

6

Page 45: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

45

SI/IP:

For heat load calculation unit, LATS includes SI, which is an international standard and IP, which is an English standard. US and middle east use IP while Europe uses SI. Some countries use IP for quantity and SI for length. This kind of mixed usage is also possible.

Simulation Mode:

Users select Cooling mode to make their projects based on cooling operation. In this case, the usage is focused on cooling. Users select Heating mode to make their project based on heating operation. In this case, the usage is focused on heating.

Outdoor Unit Type

Users can decide the outdoor unit type that they want from the drop down button.

Detailed Comments for the project

Users enter their detailed comments on this blank. Users check the checkbox of Use CAD to use CAD Mode.

Caution:

Be sure to active Use CAD option if you are using CAD drawing for model selection. To Use Tree mode, do not check it.

Note :

<Tree mode> <CAD mode>

Tree mode shows the design as a tree shape.

Cad mode shows the design on an existing CAD drawuing.

Output can be transformed as a DXF file and opened at Auto CAD to be editted.

6

5

Page 46: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

46

From this Create Project window, enter the project information. Then click Next.

- Date that the project is created

- Project Name

- Path of the project to save it

- Project Unit

- Simulatino Mode

- Outdoor Unit Type

- Detailed Comments for the project

3. Select country and city. Then input design condition.

Change design condition if the given values do not satisfy your requirements.

If you change one of the following air property (DBT,WBT,RH), psychometric process will be executed. Other related values will be found.

Click Next.

Insert the country, State/Province and City information.

Dry bulb temperature, Wet bulb temperature and Relative humidity should be inserted. This information should be inserted for each indoor and outdoor both in Cooling and Heating condition.

4. When selecting Open Load, you can load the result calculated by LATS-LOAD. Click Open load

button.

- Open load

You can open the load information that was previously calculated by LATS Load program.

1

tha

t

the

pr

oject

is

cre

ated

Pat

h of

th

e pr

oje

ct

to sav

e

it Pr

oje

ct Na

me

Pr

oject

Un

it SI :

IP:

De

tail

2

tha

t

the

pr

oject

is

cre

ated

Pat

h of

th

e pr

oje

ct

to sav

e

it Pr

oje

ct Na

me

Pr

oject

1

that

th

e

proje

ct

is cre

ate

d

Path

of

the

pr

oject

to

sav

2 tha

t

th

e pr

oje

ct is

cre

ated

Pat

h

of th

e

proje

ct

to

Page 47: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

47

- Add floor/Add space

If you do not use the previously calculated value of LATS Load program, you can manually insert the floor information with this button.

- Remove row, Remove all

These two buttons are activated only when floors are added manually in advance. This button removes the currently added row or removes all rows. After you complete your setting, click Next.

5. From this window you can select the pre-calculated heat load of Load program. Select one and click OK.

6. The pre-calculated information is displayed as follows.

If you do not have the pre-defined value, click Add floor or Add space to add a new row. To remove it, click Remove all button. If LATS LOAD values are not available, manual load entry can also be done simply by adding values in columns.

Click Next.

Page 48: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

48

7. Input Customer & contractor Information. It will be printed out on your final report. After filling all data, click Finish.

Then model selection window appears.

From this window, you can start selecting outdoor units, indoor units, branch pipes and header pipes according to our design. Initial window for Multi V program looks like this.

1. Click icon to import CAD files, DWG files,

onto this initial window for CAD Mode.

■ Step 2. Select Model

Page 49: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

49

This is the description for icons in CAD drawing tool bar.

Icon Description Icon Description

Undo

Delete units

Redo

Insert Climb

Zoom in Insert Y Brances and headers

Zoom out

Create network

Zoom zone

Rotate units in 90 degrees.

Fit for the screen

Rotate units

Pan

Unit Selection

Grid

Insert Outdoor unit

Orthogonal

Insert Indoor unit

Import AutoCAD drawing, dxf file Insert Space

Export Drawing to dxf file

Insert pipes

Unit Selection

Lef Arrow

Top Arrow

Y-Branch Auto Arrow

Page 50: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

50

2. From the popup window, choose a dwg file that you want. Then click Open.

This will open CAD drawing with message “CAD file is successfully open.” Click on this pop-up window.

Then following CAD file is loaded.

Page 51: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

51

3. It would support 2 scale modes.

To input text directly, you should know the drawing scale. Choose proper scale for opening CAD drawing and then click Set. To use drawing line, after inputting line length, click Draw scale line and you should draw the line equal to the length you inputted in CAD drawing. After finishing the

scaling, click Exit. You can see the imported CAD drawing like this. If it is out of screen area, click Fit Window icon for resizing it.

4. Click the New Room icon for specifying load to different location. Then this window appears.

When selecting Open Load, You can load the result calculated by LATS-LOAD program. Add floor or Add space as required. For adding and removing Floor or Space, first click on the row and then click Add or Remove. If LATS LOAD values are not available, manual load entry can also be done simply by adding values in columns. Click on one row and double click the blank to insert the value. Then click OK.

Page 52: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

52

5. Click your cursor on a specific location (in CAD drawing) where you want to locate this load information. Likewise choose other locations by repeating the above step.

Page 53: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

53

6. Click the New Indoor Unit icon. This window appears.

Choose indoor unit type and model. Click Accessory (if any required)

7. This window appears. Choose accessories if it is required. Then click OK.

Page 54: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

54

8. Then click your cursor at the specific location where you want to locate your indoor unit. Repeat the same steps to locate other indoor units. You can use copy paste command also for locating other indoor units.

Page 55: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

55

9. Click to connect room information and IDU.

Page 56: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

56

10. Adjust indoor unit direction by clicking Indoor Unit and then

Rotate Angle icon. This window appears. Fill in the required rotation angle and then click OK. You can see pipe connecting point (as dash) at this location of indoor unit.

Caution:

All rotation will be taken place by considering initial position as reference.

Caution:

You have to connect the middle of Room to the middle of IDU, with your mouse. (marked “X” in middle point).

Page 57: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

57

11. Click outdoor unit icon. This window will appear

Outdoor unit window appears. Outdoor unit information supports these types:.

- Search Model : It lists models according to a category

- Full Model : It lists all models in same ODU type

- Auto Selection : It lists supporting model to designed system. (below 100% combination)

We recommend you using auto selection. If you use defrosting factor, check Defrosting factor

Other optional accessories can also be chosen by clicking Accessories button. After selecting above value, click OK.

Page 58: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

58

12. Click your cursor at a specific location where you want to locate your outdoor unit. You can see outdoor unit icon like the sign on this picture.

Caution:

One outdoor unit should have only one system.

Page 59: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

59

1. Click New Equipment icon to see this window. Select Y-branch or Header if it is required. Then click OK.

Menu Description

Indoor Units Indoor Units

Y branch This equipment is used for large volume of systems. Pipe can have two brances. Numbers are set before a specific model name is assigned. Specific model is assigned after auto piping.

4 header Pipe has 4 branches.

7 header Pipe has 7 branches.

10 header Pipe has 10 branches. Header is rarely used because of the difficulty in installation. This is used for small volume system.

■ Step 3. Draw System and Design Piping

Caution:

Assigning heat load for room, indoor unit, outdoor unit and pipes has no specific fixed order. You can start assigning any of them first.

Page 60: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

60

2. Then click your cursor at a specific location where you want to locate your new equipment unit, Y-Branch. You can adjust Y-branch direction by

clicking Y-branch and then Rotate Angle icon.

You can adjust Y-branch direction by clicking Y-branch and then Rotate Angle icon. This window appears. Fill in the required rotation angle and then click OK. You can see pipe connecting point (as dash) at this location of indoor unit. All rotation will be taken place by considering initial position as reference.

Page 61: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

61

3. Click New Pipe icon. Then click & drag left button of your mouse on the drawing and finally release this button at indoor/Y-branch, which

is the end point of that pipe.

You can see drawn pipe between outdoor and Y-branch or Y-branch and Indoor units like the above sample. Connect pipes between various unit, outdoor unit, Y-branch/header and indoor units.

Page 62: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

62

When you connect the indoor units, Y- branch and outdoor units, they should be connected with line, which starts from the red dot and ends at the red dot.

Caution:

Use Ortho On/Off option for drawing orthogonal pipe. After drawing pipes, right click on the pipe (on white color indenter in the middle of pipe) and drag it slightly with Shift Key pressed for locating your pipe orthogonally.

You have to connect the object to the object clearly. If you move your pointer near

to the connection mark, the pointer would be attached to the connection point.

Page 63: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

63

4. In the Floor Viewer panel on your initial window, you can add new floor. Right click on Floor0 and choose

Add Floor.

Note:

<Original> <After rotation>

Outer line of indoor unit has small white rectangle, when it is clicked. Left click a mouse and move the mouse to move

indoor units. Or click to insert an exact angle value for rotation.

Page 64: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

64

5. After adding floor, right click on the same floor (Floor1 icon) and click Edit icon to see a popup window. Fill in the floor height from outdoor unit

and then click Ok. To import CAD drawing, repeat the above step.

After adding floor, perform the same operation like the above explanation. Add Room, Indoor Units, Y-branch/Header and Pipes on the new floor like the explanation above.

6. Click New Climb icon for connecting added floor (Floor1)

to the previous floor (Floor0). This popup window appears. Select the floor to link with work floor by climb and click Ok.

Page 65: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

65

7. Click your cursor at a specific location where you want to locate Climb piping and connect line. You can see this Icon and message “Connected to Floor1” which shows the connected floor.

“Connected to Floor1” is connected with an indoor unit. Then this indoor unit is connected to the ourdoor unit at the Floor1 through the “Connected from Floor0” part.

Outdoor unit should have only one connection line.

Page 66: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

66

As you see, the other floor has the same icon, which says “Connected from Floor0.”

Then this two floors are connected well.

8. Click Create Network icon for connecting network. If the connection between pipe and Indoor unit, Y-branch or Outdoor unit is not proper you can see an Error message in your Log Viewer with Error Icon located on wrong connection. Reconnect Error Pipe for further processing. You can see a message “Start Creating Network” in your System Log Viewer.

After correcting pipe connection, click Create Network icon again. If pipes are connected properly then Network Completion message will appear in Log Viewer.

Page 67: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

67

Note:

Pipe and Indoor unit are not connected tightly. Branch and pipe are not connected well.

Pipe is not positioned at the red line of an indoor unit. Select a pipe to connect it to the branch tightly.

Select a pipe again to connect it to the red point of an

indoor unit.

Page 68: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

68

9. Click Auto Piping icon from the left part of an initial window. Auto Piping command automatically selects Y-branch/Header branch name, pipe diameter and pipe length.

Page 69: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

69

10. The this window appears to confirm your selection. Click OK.

If any problem is not occurred, All branches and header models are selected automatically. If Y branch or Header exists, you have to change pipe design or check branch or Header in PDB.

Page 70: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

70

1. Click System Check to simulate the system. System Check supports

validation check and performance simulation.

- Validation check : It checks total piping length, the longest pipe length after 1st branch, each pipe length and all validation in PDB.

- Performance simulation : It simulates system’s performance from combination, design condition, pipe length and defrosting factor.

Each indoor unit capacity is simulated and changed. After system is checked, this window appears. Click OK.

If there is an error message. Fix the error and perform these steps again.

1. Create Network

2. Auto piping

3. System Check

2. Click Tree icon for

seeing line diagram of this system

Pipe length in Tree Mode is equivalent length.

So pipe length in CAD mode is not same with that of Tree Mode.

Pipe length in CAD mode is real length.

■ Step 4. Check System

Page 71: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

71

This is the interpretation for this result, marked on the above picture.

Menu Description

Indoor Units 6 indoor units were installed among 8 available units.

Combination Combination ratio is 98%.

Total Pipe 39.2 m of total 220.0 m pipes are installed for the outdoor unit.

If you try to change the information of units or pipes in this Tree Mode, this message appears. Once you start your project from CAD Mode, you have to modify it and finish it in CAD Mode. In CAD Mode, you can only read the information at Tree Mode.

Caution:

If the combination ratio does not meet the rule of PDB, the design process stops here and does not move to the next step.

Caution:

Once you click Tree Mode button and enter into the Tree Mode display, you have to click “Create Network” button again to go back to CAD mode.

Page 72: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

72

3. Press Schematic

Diagram button to see this display.

Check Additional refrigerant and Wiring design. If you want to go back to Tree Mode, you can press Tree button of the left part of initial window.

Click either of these icons for seeing control wire, power line and pipe line.

CL: shows Communication Line

PC: shows Power Line Communication

PL shows Pipe Line

4. Click Drawing Export icon . Input the name of exporting file and click Save. You can

save your drawing file as a DXF file.

Page 73: Lats-Multi v-Multi v Model Selection[20071204093730603]

LATS Multi V Model Selection Program

73

1. Click Generate Report on the left part of initial window. This window appears. Select the sheet of reports to make. Then click OK.

Finally press OK for viewing the above chosen report on excel sheet.

You can see the final report at the Tree Mode description part of this User Guide.

Caution:

You need MS Excel program installed on your computer to get your output as a report form.

■ Step 5. Write the report

Page 74: Lats-Multi v-Multi v Model Selection[20071204093730603]

3. Tips for using Multi V Model selection program

Set Scale

Assign one load for one indoor unit

Draw orthogonal pipes

When you open a CAD drawing from AUTO CAD, scale is changed. After you handle your CAD file on LATS, maginify it 10 times to be well fitted for proper scale.

Original CAD file CAD file Exported from LATS

Set Scale in Multi V Model selection program

Page 75: Lats-Multi v-Multi v Model Selection[20071204093730603]

Tips for using Multi V Model selection program

75

When there is two indoor units for one heat load for a room, devide one heat load into two parts. Connect only one heat load for one indoor unit.

Wrong example Right example

Assign one load for one indoor unit in Multi V Model selection program

Page 76: Lats-Multi v-Multi v Model Selection[20071204093730603]

Tips for using Multi V Model selection program

76

Click Grid On/Off icon from the initial window. Then an window appears for you to insert a gap value between grid. Inser the number and you can see the grid on your display.

Click Grid On/Off icon Grid Display

Click Orthogonal icon from the initial window.

When you move units or draw pipes, you can do your work in horizontal or vertical direction by activating Orthogonal function. You can use Orthogonal and Grid function simultaneously.

1. Click Orthogonal button in the Drawing toolbar.

2-1. During moving unit(s), You can move them only in horizontal or vertical direction.

2-2. During drawing pipes. You can draw them only in horizontal or vertical direction.

3. To deactivate Orthogonal function, Click Orthogonal button again.

Draw orthogonal pipes in Multi V Model selection program

Page 77: Lats-Multi v-Multi v Model Selection[20071204093730603]

Tips for using Multi V Model selection program

77

Click Pan icon to pan CAD work window at an arbitrary direction.

1. Click Pan button in the Drawing toolbar.

2. Click and hold left-button of mouse in the CAD window.

3. Move your mouse point in the CAD window.

4. You can see CAD window moves to the direction that a mouse point moves.

5. Release left-button of mouse. So you can see the moved view position of CAD window.

6. To deactivate Pan function, Click Pan button again, hit any key or click center/right-button of mouse.

If you have a mouse with middle-button of wheel-button, you can pan CAD Work window.

1. Click middle-button or wheel-button of mouse in the CAD Work window.

2. Move your mouse point in the CAD work window.

3. Release middle-button or wheel-button of mouse.

Page 78: Lats-Multi v-Multi v Model Selection[20071204093730603]

4. Contact Information

LATS program ownership

PM Group, Air conditioner Lab, Digital Appliance Company, LG Electronics.

Question and further information

Access this site and insert your question. Then the specific local engineers or managers for each region will contact you.

http://www.lgeaircon.com/cac.cssupport.qna.qna.createQuestioner.laf

Page 79: Lats-Multi v-Multi v Model Selection[20071204093730603]

Contact Information