lcws2013 tokyo denkai co., ltd. rrr and thickness measurements of cu plating hiroaki umezawa,...

17
LCWS2013 Tokyo Denkai Co., Ltd. RRR and thickness measurements of Cu plating Hiroaki Umezawa, Futoshi Saito Tokyo Denkai Co., Ltd. Eiji Kako KEK

Upload: lynn-chase

Post on 13-Dec-2015

226 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: LCWS2013 Tokyo Denkai Co., Ltd. RRR and thickness measurements of Cu plating Hiroaki Umezawa, Futoshi Saito Tokyo Denkai Co., Ltd. Eiji Kako KEK

LCWS2013 Tokyo Denkai Co., Ltd.

RRR and thickness measurements of Cu plating

Hiroaki Umezawa, Futoshi SaitoTokyo Denkai Co., Ltd.

Eiji KakoKEK

Page 2: LCWS2013 Tokyo Denkai Co., Ltd. RRR and thickness measurements of Cu plating Hiroaki Umezawa, Futoshi Saito Tokyo Denkai Co., Ltd. Eiji Kako KEK

LCWS2013 Tokyo Denkai Co., Ltd.

Contents• Background• RRR Measurement Method of Cu Plating• Thickness Measurement of Cu Plating• RRR Measurement result• Summary

Page 3: LCWS2013 Tokyo Denkai Co., Ltd. RRR and thickness measurements of Cu plating Hiroaki Umezawa, Futoshi Saito Tokyo Denkai Co., Ltd. Eiji Kako KEK

LCWS2013 Tokyo Denkai Co., Ltd.

BackgroundMaterial for Input coupler• Low thermal conductivity is required to suppress

heat transfer from outside of cryostat.• High electric conductivity (i.e. low resistance) is

required to suppress RF resistance.↓

Very thin copper plated SUS (0.8mm)↓

Evaluation of electric conductivity and thermal conductivity of the cu plating is necessary.

↓RRR measurement of Cu plating (Target value 30-60)

Page 4: LCWS2013 Tokyo Denkai Co., Ltd. RRR and thickness measurements of Cu plating Hiroaki Umezawa, Futoshi Saito Tokyo Denkai Co., Ltd. Eiji Kako KEK

LCWS2013 Tokyo Denkai Co., Ltd.

RRR Measurement System

Page 5: LCWS2013 Tokyo Denkai Co., Ltd. RRR and thickness measurements of Cu plating Hiroaki Umezawa, Futoshi Saito Tokyo Denkai Co., Ltd. Eiji Kako KEK

LCWS2013 Tokyo Denkai Co., Ltd.

How to calculate RRR of the Cu plating

RRR =ρ 293Kρ10K

1

RCu / SUS=1

RCu+1

RSUS1

ρCu / SUS ⋅l

S1

=1

ρCu ⋅l

S3

+1

ρ SUS ⋅l

S2S1

ρCu / SUS=S3ρCu+S2ρ SUS

S3ρCu

=S1

ρCu / SUS−S2ρ SUS

ρCu =S3

S1ρCu / SUS

−S2ρ SUS

ρCu

ρSUS

ρCu/SUS

tCu tCu/SUS

tSUS

L110mm

W 5mm

S2=W・ tSUS

S3=W・ tCu

S1=W・ tCu/SUS

Page 6: LCWS2013 Tokyo Denkai Co., Ltd. RRR and thickness measurements of Cu plating Hiroaki Umezawa, Futoshi Saito Tokyo Denkai Co., Ltd. Eiji Kako KEK

LCWS2013 Tokyo Denkai Co., Ltd.

Sample preparation• During the input coupler production, heat

history of 800C will be added in hydrogen atmosphere due to the brazing.

• To research the influence of this heat treatment(HT), we prepared 2 types of samples which are heat treated and not heat treated. #Simulation of brazing condition.

• 3 samples from each types are prepared, 2 samples for RRR measurement, 1 sample for Cu plating thickness measurement.

Page 7: LCWS2013 Tokyo Denkai Co., Ltd. RRR and thickness measurements of Cu plating Hiroaki Umezawa, Futoshi Saito Tokyo Denkai Co., Ltd. Eiji Kako KEK

LCWS2013 Tokyo Denkai Co., Ltd.

Sample

Before HT After HT

A1,2,3 A4,5,6 A

B1,2,3 B4,5,6 A

C1,2,3 C4,5,6 A

D1,2,3 D4,5,6 A

E1,2,3 E4,5,6 B

F1,2,3 F4,5,6 B

G1,2,3 G4,5,6 C

H1,2,3 H4,5,6 C

Ni Strike + Cu 11.7 um Copper Cyanide Plating

Ni Strike + Cu 35 um Copper Cyanide Plating

Ni Strike + Cu 5 um Copper Cyanide Plating

Ni Strike + Cu 20 um Copper Cyanide Plating

Ni Strike + Cu 5.4 um Copper pyrophosphate Plating

Ni Strike + Cu 20.6 um Copper pyrophosphate Plating

Au Strike + Cu 5.2 um Copper pyrophosphate Plating

Au Strike + Cu 19.2 um Copper pyrophosphate Plating

Sample No. Plating

Vender

Condition of Cu Plating

Thickness of Cu Plating Plating Method

Page 8: LCWS2013 Tokyo Denkai Co., Ltd. RRR and thickness measurements of Cu plating Hiroaki Umezawa, Futoshi Saito Tokyo Denkai Co., Ltd. Eiji Kako KEK

LCWS2013 Tokyo Denkai Co., Ltd.

Sample

Page 9: LCWS2013 Tokyo Denkai Co., Ltd. RRR and thickness measurements of Cu plating Hiroaki Umezawa, Futoshi Saito Tokyo Denkai Co., Ltd. Eiji Kako KEK

LCWS2013 Tokyo Denkai Co., Ltd.

Cu remove

The copper is melted by HN03

Au Strike Ni Strike

Page 10: LCWS2013 Tokyo Denkai Co., Ltd. RRR and thickness measurements of Cu plating Hiroaki Umezawa, Futoshi Saito Tokyo Denkai Co., Ltd. Eiji Kako KEK

LCWS2013 Tokyo Denkai Co., Ltd.

Digital Micro Scope

Page 11: LCWS2013 Tokyo Denkai Co., Ltd. RRR and thickness measurements of Cu plating Hiroaki Umezawa, Futoshi Saito Tokyo Denkai Co., Ltd. Eiji Kako KEK

LCWS2013 Tokyo Denkai Co., Ltd.

Plating Thickness Measurement

Sample A: 18um Sample B: 3um

Page 12: LCWS2013 Tokyo Denkai Co., Ltd. RRR and thickness measurements of Cu plating Hiroaki Umezawa, Futoshi Saito Tokyo Denkai Co., Ltd. Eiji Kako KEK

LCWS2013 Tokyo Denkai Co., Ltd.

Measurement Result of Plating Thickness

Sample Vender Report Before HT After HT

A 5.2 15.9 18.2

B 19.2 5.9 3.2

C 5.4 20.7 18.8

D 20.6 3.9 2.9

E 5.0 4.0 2.1

F 20.0 6.8 6.6

G 11.7 10.7 10.9

H 35.0 29.1 29.5

(um)

Measured by Microscope

Page 13: LCWS2013 Tokyo Denkai Co., Ltd. RRR and thickness measurements of Cu plating Hiroaki Umezawa, Futoshi Saito Tokyo Denkai Co., Ltd. Eiji Kako KEK

LCWS2013 Tokyo Denkai Co., Ltd.

Thickness of Cu Plating

0

5

10

15

20

25

30

35

40

A B C D E F G H

Sample

Thickness of Cu Plating [um]

Before HTAfter HTNominal Value

Page 14: LCWS2013 Tokyo Denkai Co., Ltd. RRR and thickness measurements of Cu plating Hiroaki Umezawa, Futoshi Saito Tokyo Denkai Co., Ltd. Eiji Kako KEK

LCWS2013 Tokyo Denkai Co., Ltd.

RRR Measurement Result

0

10

20

30

40

50

60

0 5 10 15 20 25 30

Thickness of Cu Plating [um]

RRR

RRR Before HT

RRR After HT

E D B FG A

C

H

E

D

B

F

G

A

C

H

Page 15: LCWS2013 Tokyo Denkai Co., Ltd. RRR and thickness measurements of Cu plating Hiroaki Umezawa, Futoshi Saito Tokyo Denkai Co., Ltd. Eiji Kako KEK

LCWS2013 Tokyo Denkai Co., Ltd.

RRR Measurement Result

0

10

20

30

40

50

60

0 5 10 15 20 25 30

Thickness of Cu Plating [um]

RRR

RRR Before HT

RRR After HT

E D B FG A

C

H

E

D

B

F

G

A

C

H

Page 16: LCWS2013 Tokyo Denkai Co., Ltd. RRR and thickness measurements of Cu plating Hiroaki Umezawa, Futoshi Saito Tokyo Denkai Co., Ltd. Eiji Kako KEK

LCWS2013 Tokyo Denkai Co., Ltd.

RRR Measurement Result

0

10

20

30

40

50

60

0 5 10 15 20 25 30

Thickness of Cu Plating [um]

RRR

RRR Before HT

RRR After HT

E D B FG A

C

H

E

D

B

F

G

A

C

H

Page 17: LCWS2013 Tokyo Denkai Co., Ltd. RRR and thickness measurements of Cu plating Hiroaki Umezawa, Futoshi Saito Tokyo Denkai Co., Ltd. Eiji Kako KEK

LCWS2013 Tokyo Denkai Co., Ltd.

Conclusion• RRR measurement and Cu plating thickness

measurement of SUS used for material of input coupler of SC Cavity was done.

• There is a difference between measured plating thickness by us and nominal plating thickness by plating vender.

• To get high RRR, plating thickness is important.• 800C heat treatment exert a negative effect on

RRR of plating. • To overcome the bad influence from heat

treatment, thickness of the plating must have at least 30 micrometer.