lighting 2

16
Street Lighting Poles

Upload: thahir-shah

Post on 06-Dec-2015

227 views

Category:

Documents


0 download

DESCRIPTION

Street Pole specs

TRANSCRIPT

Page 1: Lighting 2

Street Lighting Poles

Page 2: Lighting 2

>> Australia’s leading manufacturer of quality pole products with representation in every state and territory.

Page 3: Lighting 2

INGAL EPS is a division of Industrial Galvanizers Corporation Pty Ltd which is ultimately owned by Valmont Industries Inc. Actively involved in the Australian pole market since 1969, INGAL EPS has strived to continuously lead the industry in research, design, innovation, quality of product and quality of service. Establishing industry benchmarks such as the Seesaw pole, 60km/h and 110km/h Impact Absorbing poles and the largest steel poles ever installed in both Australia and New Zealand.

The company employs around 150 staff and has offices located in every state and territory of Australia and on the North Island of New Zealand. With manufacturing facilities in Brisbane and Perth and full access to three modern facilities in China owned by Valmont Industries Inc, INGAL EPS is well positioned to meet the broad requirements of the pole market. Due to our extensive experience, national coverage, resources and manufacturing capacity we have the ability to provide the most comprehensive product range available.

The INGAL EPS product range includes:

• Street Lighting poles

• Floodlighting poles

• Power poles

• Lowering Systems, for ease of maintenance

• Special Application poles including banner poles, camera poles, traffic signal and communication poles

• Services & Accessories providing individual design, drafting, installation and accessories including foundation materials, adaptors, headframes and cross arms.

With our dedicated design service, material control, quality assured manufacturing processes and after sales service, INGAL EPS has established itself as Australasia’s largest pole supplier. INGAL EPS has over four decades of experience leading the industry in Australia and our ever improving product range and expanded manufacturing resources will continue to ensure we’re at the cutting edge of providing new and innovative solutions to a growing and ever more demanding market.

Page 4: Lighting 2

Avenue Pole

Page 5: Lighting 2

STrEET LIGhTING PoLES | PAGe 5

AvenueINGAL EPS design and manufactures street lighting poles for Category P & V lighting requirements. The Avenue range of poles are predominantly designed for Category P (pedestrian) and are ideally suited for use in residential subdivisions, commercial developments, recreational pathways and parks.

options and Accessories• Avenue Street Lighting poles are base plate mounted as standard but can be designed for in-ground mounting• The poles are hot dip galvanized and can be powder coated or painted in the colour of your choice• The range is available in tapered octagonal only• Standard mounting heights are 5.5m to 12m• Standard outreach lengths are 1.5m to 3m• The standard poles are depicted on this product sheet, however they can be designed for differing heights and outreach lengths• Avenue poles are also available in a Seesaw configuration, refer to the Lowering Systems brochure for further information.• Preassembly• Pre cabling• Installation

Product Codes For more information, please refer to the Technical Data Sheet.

Avenue (Tapered Octagonal)

5.5m 6.5m 7.5m 9m 10.5m 12m

SAl55FSo15 SAl65FSo15 SAl75FSo15 SAl9FSo15 SAl105FSo15 SAl12FSo15SAl55FSo20 SAl65FSo20 SAl75FSo20 SAl9FSo20 SAl105FSo20 SAl12FSo20SAl55FSo30 SAl65FSo30 SAl75FSo30 SAl9FSo30 SAl105FSo30 SAl12FSo30SAl55FDo15 SAl65FDo15 SAl75FDo15 SAl9FDo15 SAl105FDo15 SAl12FDo15SAl55FDo20 SAl65FDo20 SAl75FDo20 SAl9FDo20 SAl105FDo20 SAl12FDo20SAl55FDo30 SAl65FDo30 SAl75FDo30 SAl9FDo30 SAl105FDo30 SAl12FDo30

S=Street lighting A=Avenue l=light Duty F=Flange Mounted (Base Plate) R=Tapered Round S=Single outreach D=Double outreach o=Tapered octagonal

Standard Avenue Poles

Page 6: Lighting 2

PAGe 6 | STrEET LIGhTING PoLES

FreewayThe Freeway Street Light range was inspired by the need for greater outreach over wide roadways. The predominantly Category V (vehicular) designed poles are ideally suited for multi-laned roads. The range is an extension of the tapered octagonal Avenue range of poles but, utilises a heavy-duty shaft allowing for outreaches up to 4.5m in length.

options and Accessories• The Freeway Street Light range is base plate mounted as standard but can be designed for in-ground mounting• The poles are hot dip galvanized and can be powder coated or painted in the colour of your choice• The range is available in tapered octagonal only• Standard mounting heights are 10.5m to 12m• Standard outreach lengths are 1.5m to 4.5m• The standard poles are depicted on this product sheet, however they can be designed for differing height and outreach lengths• Preassembly• Pre cabling• Installation

Product Codes For more information, please refer to the Technical Data Sheet.

Freeway

10.5m 10.5m 12m 12m

SFl105FSo15 SFl105FDo15 SFl12FSo15 SFl12FDo15

SFl105FSo20 SFl105FDo20 SFl12FSo20 SFl12FDo20

SFl105FSo30 SFl105FDo30 SFl12FSo30 SFl12FDo30

SFl105FSo45 SFl105FDo45 SFl12FSo45

S=Street lighting F=Freeway l=light Duty F=Flange Mounted (Base Plate) S=Single outreach D=Double outreach o=Tapered octagonal

Freeway Poles Standard Freeway Poles

Page 7: Lighting 2

FReewAy Pole

Page 8: Lighting 2

IMPAcT ABSoRBInG Pole

Page 9: Lighting 2

STrEET LIGhTING PoLES | PAGe 9

Impact AbsorbingINGAL EPS has been the largest supplier of street light poles to Australian road, power and council organisations and their contractors for over 40 years. often being the original designer of the Impact Absorbing poles they now refer to as their own.

Impact Absorbing pole shaft Typical Impact Absorbing Pole

INGAL EPS have been design and manufacturing Impact Absorbing poles since 1979, and were the first to have the designs tested to the relevant standard (AS/NZS 1158.1.3) for both 60km/h and 110km/h zones. Under design criteria and circumstances, the poles will stop a vehicle and minimise the force on the vehicle’s occupants. The pole remains attached to the base structure and absorbs impact energy progressively, entrapping the impacting vehicle as the pole deforms. An impact absorbing pole looks similar to a normal rigid pole but features innovative vertical slots at the base to create a cushioning effect if the pole is hit by a vehicle. Standard height and outreach lengths vary according to relevant authority specifications.

options and Accessories• Impact Absorbing poles can be either base plate or

in-ground mounted• The poles are hot dip galvanized and can be powder

coated or painted in the colour of your choice• Available in tapered round and tapered octagonal• Mounting heights and outreach lengths vary according to

the relevant authority’s specification• Standard Australian road and power authority poles are

depicted on this product sheet, however varying heights and outreach lengths can be designed for your application

• Design, testing and certifying of Impact Absorbing pole designs• Preassembly• Pre cabling• Installation

organisations we supply Impact Absorbing Poles for include:

• ActewAGL (ACT)• Adelaide City Council (SA)• Aurora Energy (Tas)• Country Energy (NSW) • Department of Transport, Energy & Infrastructure (SA)• Energy Australia (NSW)• ETSA Utilities (SA)• horizon Power (WA)• Integral Energy (NSW)• Jemena (Vic)• Main roads (WA)• NT roads (NT)• Powercor (Vic)• Power & Water (NT)• roads & Traffic Authority NSW (NSW)• SP AusNet (Vic)• Tenix Alliance (Vic)• Vicroads (Vic)• Western Power Corporation (WA)

Page 10: Lighting 2

PAGe 10 | STrEET LIGhTING PoLES

Slip BaseINGAL EPS has been the largest supplier of street light poles to Australian road, power and council organisations and their contractors for over 40 years. often being the original designer of the Slip Base poles they now refer to as their own.

close up of slip area Typical Slip Base arrangement

The revolutionary engineering design of Slip Base poles enables the pole to slip at the base and fall if a collision occurs. This ideally suits freeways and other high-speed roadways where the likelihood of a secondary accident, resulting from the falling pole, is accepted as being unlikely. The standard height and outreach lengths vary according to relevant authority specifications.

options and Accessories• Slip Base Poles are base plate mounted, either on an

in-ground section or concrete foundation• The poles are hot dip galvanized and can be powder coated

or painted in the colour of your choice• Slip Base poles are available in tapered round and

tapered octagonal• Standard Australian road authority poles are depicted on this

product sheet, however varying heights and outreach lengths can be designed for your application

• Design, testing and certifying of Slip Base Pole designs• Preassembly• Pre cabling• Installation

organisations we supply Slip Base Poles for include:

• Brisbane City Council (Qld)• Country Energy (NSW)• Department of Transport, Energy & Infrastructure (SA)• Energex (Qld)• Energy Australia (NSW) • Ergon Energy (Qld)• Jemena (Vic)• Main roads Qld (Qld)• Main roads (WA)• NT roads (NT)• Power & Water (NT)• Powercor (Vic)• roads & Traffic Authority NSW (NSW)• SP AusNet (Vic)• Tenix Alliance (Vic)• Vicroads (Vic)

Page 11: Lighting 2

Typical Slip Base arrangement

SlIP BASe Pole

Page 12: Lighting 2

STrE

ET L

IGh

TIN

G P

oLE

S |

PAG

e 12

Tech

nica

l Inf

orm

atio

nn

oM

InA

l H

eIG

HT

(m

)

cAT

Alo

Gu

e

no.

Pole

DIA

MeT

eRD

oo

R S

Ize

l x

w

(mm

)x(m

m)

BolT

SM

Ax

. To

P w

eIG

HT

(k

g)

MA

xIM

uM

All

ow

ABl

e SA

Il A

ReA

(M

2 )

ReG

Ion

- T

eRR

AIn

cAT

eGo

Ry (

AS1

170.

2)u

lT. B

ASe

M

oM

enT

(k

nm

)

ulT

. BA

Se

SHeA

R

(kn

)

wo

Rk

. BA

Se

Mo

Men

T

(kn

m)

wo

Rk

. BA

Se

SHeA

R

(kn

)

ScR

ew

PIle

Pole

w

eIG

HT

(k

g)To

P (m

m)

BoT.

(m

m)

A-2

A-3

B-2

B-3

c-2

c-3

D-2

D-3

Ave

nue

(Tap

ered

Oct

ago

nal S

ingl

e O

utre

ach)

5.5

SAl5

5FSo

1543

144

295

x 9

0 4

M20

@23

330

0.16

0.16

0.16

0.16

0.16

0.16

- 0.

1611

.03.

07.

32.

02A

465.

5SA

l55F

So20

4314

429

5 x

90

4M

20@

233

300.

160.

160.

160.

160.

160.

16-

0.16

11.0

3.0

7.3

2.0

2A49

5.5

SAl5

5FSo

3057

144

295

x 9

0 4

M20

@23

330

0.16

0.16

0.16

0.16

0.16

0.16

- -

11.0

3.0

7.3

2.0

2A54

6.5

SAl6

5FSo

1543

160

295

x 9

0 4

M20

@23

330

0.16

0.16

0.16

0.16

0.16

0.16

- 0.

1614

.03.

39.

32.

2n/

a57

6.5

SAl6

5FSo

2043

160

295

x 9

0 4

M20

@23

330

0.16

0.16

0.16

0.16

0.16

0.16

- -

14.0

3.3

9.3

2.2

n/a

606.

5SA

l65F

So30

5716

029

5 x

90

4M

20@

233

300.

160.

160.

160.

16-

0.16

- -

14.0

3.3

9.3

2.2

n/a

657.

5SA

l75F

So15

4315

129

5 x

90

4M

24@

350

300.

160.

160.

160.

160.

160.

16-

0.16

13.0

3.0

8.7

2.0

3A79

7.5

SAl7

5FSo

2043

151

295

x 9

0 4

M24

@35

030

0.16

0.16

0.16

0.16

- 0.

16-

- 13

.03.

08.

72.

03A

827.

5SA

l75F

So30

5715

129

5 x

90

4M

24@

350

300.

160.

160.

160.

16-

0.16

- -

13.0

3.0

8.7

2.0

3A87

9SA

l9FS

o15

4317

129

5 x

110

4M

24@

350

300.

160.

160.

160.

160.

160.

16-

0.16

20.2

3.0

13.5

2.0

3A10

69

SAl9

FSo

2043

171

295

x 1

10 4

M24

@35

030

0.16

0.16

0.16

0.16

- 0.

16-

- 20

.23.

013

.52.

03A

109

9SA

l9FS

o30

5717

129

5 x

110

4M

24@

350

300.

160.

160.

160.

16-

0.16

- -

20.2

3.0

13.5

2.0

3A11

410

.5SA

l105

FSo

1543

182

410

x 1

10 4

M24

@35

030

0.16

0.16

0.16

0.16

- 0.

16-

- 20

.23.

513

.52.

33A

127

10.5

SAl1

05FS

o20

4318

241

0 x

110

4M

24@

350

300.

160.

160.

160.

16-

0.16

- -

20.2

3.5

13.5

2.3

3A13

010

.5SA

l105

FSo

3057

182

410

x 1

10 4

M24

@35

030

0.16

0.16

0.16

0.16

- -

- -

20.2

3.5

13.5

2.3

3A13

512

SAl1

2FSo

1543

201

410

x 1

10 4

M24

@35

030

0.16

0.16

0.16

0.16

- 0.

16-

- 26

.54.

017

.72.

73B

151

12SA

l12F

So20

4320

141

0 x

110

4M

24@

350

300.

160.

160.

160.

16-

0.16

- -

26.5

4.0

17.7

2.7

3B15

412

SAl1

2FSo

3057

201

410

x 1

10 4

M24

@35

030

0.16

0.16

- 0.

16-

- -

- 26

.54.

017

.72.

73B

159

Ave

nue

(Tap

ered

Oct

ago

nal D

oub

le O

utre

ach)

5.5

SAl5

5FD

o15

4314

429

5 x

90

4M

20@

233

600.

160.

160.

160.

16-

0.16

- -

11.0

3.0

7.3

2.0

2A57

5.5

SAl5

5FD

o20

4314

429

5 x

90

4M

20@

233

600.

160.

160.

160.

16-

0.16

- -

11.0

3.0

7.3

2.0

2A61

5.5

SAl5

5FD

o30

5714

429

5 x

90

4M

20@

233

600.

160.

160.

160.

16-

0.16

- -

11.0

3.0

7.3

2.0

2A73

6.5

SAl6

5FD

o15

4316

029

5 x

90

4M

20@

233

600.

160.

160.

160.

16-

0.16

- -

14.0

3.3

9.3

2.2

n/a

686.

5SA

l65F

Do

2043

160

295

x 9

0 4

M20

@23

360

0.16

0.16

0.16

0.16

- -

- -

14.0

3.3

9.3

2.2

n/a

726.

5SA

l65F

Do

3057

160

295

x 9

0 4

M20

@23

360

0.16

0.16

- 0.

16-

- -

- 14

.03.

39.

32.

2n/

a88

7.5

SAl7

5FD

o15

4315

129

5 x

90

4M

24@

350

600.

160.

160.

160.

16-

- -

- 13

.03.

08.

72.

03A

897.

5SA

l75F

Do

2043

151

295

x 9

0 4

M24

@35

060

0.16

0.16

- 0.

16-

- -

- 13

.03.

08.

72.

03A

947.

5SA

l75F

Do

3057

151

295

x 9

0 4

M24

@35

060

0.16

0.16

- 0.

16-

- -

- 13

.03.

08.

72.

03A

106

9SA

l9FD

o15

4317

129

5 x

110

4M

24@

350

600.

160.

160.

160.

16-

0.16

- -

20.2

3.0

13.5

2.0

3A11

69

SAl9

FDo

2043

171

295

x 1

10 4

M24

@35

060

0.16

0.16

- 0.

16-

- -

- 20

.23.

013

.52.

03A

121

9SA

l9FD

o30

5717

129

5 x

110

4M

24@

350

60-

0.16

- -

- -

- -

20.2

3.0

13.5

2.0

3A13

310

.5SA

l105

FDo

1543

182

410

x 1

10 4

M24

@35

060

- 0.

16-

0.16

- -

- -

20.2

3.5

13.5

2.3

3A13

710

.5SA

l105

FDo

2043

182

410

x 1

10 4

M24

@35

060

- 0.

16-

- -

- -

- 20

.23.

513

.52.

33A

142

10.5

SAl1

05FD

o30

5718

241

0 x

110

4M

24@

350

60-

0.16

- -

- -

- -

20.2

3.5

13.5

2.3

3A15

4

Page 13: Lighting 2

no

MIn

Al

HeI

GH

T

(m)

cAT

Alo

Gu

e

no.

Pole

DIA

MeT

eRD

oo

R S

Ize

l x

w

(mm

)x(m

m)

BolT

SM

Ax

. To

P w

eIG

HT

(k

g)

MA

xIM

uM

All

ow

ABl

e SA

Il A

ReA

(M

2 )

ReG

Ion

- T

eRR

AIn

cAT

eGo

Ry (

AS1

170.

2)u

lT. B

ASe

M

oM

enT

(k

nm

)

ulT

. BA

Se

SHeA

R

(kn

)

wo

Rk

. BA

Se

Mo

Men

T

(kn

m)

wo

Rk

. BA

Se

SHeA

R

(kn

)

ScR

ew

PIle

Pole

w

eIG

HT

(k

g)To

P (m

m)

BoT.

(m

m)

A-2

A-3

B-2

B-3

c-2

c-3

D-2

D-3

Ave

nue

(Tap

ered

Oct

ago

nal D

oub

le O

utre

ach)

- Co

ntin

ued

12SA

l12F

Do

1543

201

410

x 1

10 4

M24

@35

060

- 0.

16-

0.16

- -

- -

26.5

4.0

17.7

2.7

3B16

112

SAl1

2FD

o20

4320

141

0 x

110

4M

24@

350

60-

0.16

- -

- -

- -

26.5

4.0

17.7

2.7

3B16

612

SAl1

2FD

o30

5720

141

0 x

110

4M

24@

350

60-

0.16

- -

- -

- -

26.5

4.0

17.7

2.7

3B17

8

The

max

imum

top

wei

ght

has

been

allo

wed

for

in a

ll ca

ses

to d

eter

min

e th

e m

axim

um s

ail a

rea.

Free

way

(Ta

pere

d O

ctag

ona

l Sin

gle

Out

reac

h)

10.5

SFl1

05FS

o15

9621

646

0 x

130

4M24

@35

030

0.16

0.16

0.16

0.16

0.16

0.16

- -

28.5

4.6

19.0

3.1

3B15

810

.5SF

l105

FSo

2090

216

460

x 1

304M

24@

350

300.

160.

160.

160.

16-

0.16

- -

28.5

4.6

19.0

3.1

3B16

210

.5SF

l105

FSo

3079

216

460

x 1

304M

24@

350

300.

160.

160.

160.

16-

0.16

- -

28.5

4.6

19.0

3.1

3B16

810

.5SF

l105

FSo

4563

214

460

x 1

304M

24@

350

300.

160.

16-

0.16

--

- -

28.5

4.6

19.0

3.1

3B17

212

SFl1

2FSo

1596

235

460

x 1

304M

24@

350

300.

160.

160.

160.

16-

0.16

- -

37.0

4.6

24.7

3.1

n/a

187

12SF

l12F

So20

9023

546

0 x

130

4M24

@35

030

0.16

0.16

0.16

0.16

-0.

16-

- 37

.04.

624

.73.

1n/

a19

012

SFl1

2FSo

3079

235

460

x 1

304M

24@

350

300.

160.

160.

160.

16-

--

- 37

.04.

624

.73.

1n/

a19

712

SFl1

2FSo

4563

232

460

x 1

304M

24@

350

300.

160.

16-

0.16

--

- -

37.0

4.6

24.7

3.1

n/a

199

Free

way

(Ta

pere

d O

ctag

ona

l Do

uble

Out

reac

h)

10.5

SFl1

05FD

o15

9621

646

0 x

130

4M24

@35

060

-0.

16-

0.16

--

--

28.5

4.6

19.0

3.1

3B17

810

.5SF

l105

FDo

2090

216

460

x 1

304M

24@

350

600.

160.

16-

0.16

--

--

28.5

4.6

19.0

3.1

3B18

510

.5SF

l105

FDo

3079

216

460

x 1

304M

24@

350

600.

160.

16-

--

--

-28

.54.

619

.03.

13B

198

10.5

SFl1

05FD

o45

6821

446

0 x

130

4M24

@35

060

-0.

16-

--

--

-28

.54.

619

.03.

13B

210

12SF

l12F

Do

1596

235

460

x 1

304M

24@

350

600.

160.

16-

0.16

--

--

37.0

4.6

24.7

3.1

n/a

207

12SF

l12F

Do

2090

235

460

x 1

304M

24@

350

60-

0.16

-0.

16-

--

-37

.04.

624

.73.

1n/

a21

412

SFl1

2FD

o30

7923

546

0 x

130

4M24

@35

060

-0.

16-

--

--

-37

.04.

624

.73.

1n/

a22

7

The

max

imum

top

wei

ght

has

been

allo

wed

for

in a

ll ca

ses

to d

eter

min

e th

e m

axim

um s

ail a

rea.

The

se c

olum

ns a

re n

ot r

ecom

men

ded

to b

e su

pplie

d w

ith c

limbi

ng r

ungs

.

Page 14: Lighting 2

SlIP BASe PoleS, ReID HIGHwAy PeRTH

Page 15: Lighting 2

STrEET LIGhTING PoLES | PAGe 15

>> STReeT lIGHTInG PoleS >> FlooDlIGHTInG PoleS >> PoweR PoleS

>> loweRInG SySTeMS >> SPecIAl APPlIcATIon PoleS >> SeRvIceS & AcceSSoRIeS

To view our entire product range, or for the most up to date product information, please visit our comprehensive on-line catalogue at www.ingaleps.com.au

Page 16: Lighting 2

ABn 40 000 545 415

FReecAll 1800 623 302

[email protected]

www.valmont.com