limit release notes - cae simulation solutions...dvs1612_static performs a static analysis with data...

18
Mai 2016 www.cae-sim-sol.com LIMIT Release Notes Version LIMIT2016

Upload: others

Post on 26-Jan-2021

11 views

Category:

Documents


0 download

TRANSCRIPT

  • Mai 2016www.cae-sim-sol.com

    LIMIT Release NotesVersion LIMIT2016

  • page 2LIMIT Release Noteswww.cae-sim-sol.com

    IntroductionThis document describes substantial changes compared to the release LIMIT_2016. Further information can be found in the following documents:

    LIMIT_2016.pdf

    Introduction

  • page 3LIMIT Release Noteswww.cae-sim-sol.com

    Novelties 2016Improved DVS1612 implementation

    New formulation for the static weld factor in multiaxial loadingin FKM and DVS1612

    Improved report generator with better stability

    New interface to Solidworks version 2015

    User programmed python modules can be used to customize GUI

    Weld Sets at Shell-Solid-Interface

    Splitting of welds for local redefinition

    Improved stress description in LIMIT-Viewer

    Simpler definition of FE-Result in LoadManager by file

    New license server

    New interfaces: ABAQUS2016 and Ansys V161/V162/V170

    Overview

  • page 4LIMIT Release Noteswww.cae-sim-sol.com

    Enhanced DVS1612Fatigue and static strength data defined in EditSetup

    Static weld factors are user defined or according to FKM

    Different equivalent stress types for weld section available

    Enhanced DVS1612 Assessment

  • page 5LIMIT Release Noteswww.cae-sim-sol.com

    Enhanced DVS1612Material selection according to EN10025

    Yield and tensile strength depending on sheet thickness

    Enhanced DVS1612 Assessment

  • page 6LIMIT Release Noteswww.cae-sim-sol.com

    Enhanced DVS1612Assessment defined in JobManager

    DVS1612_FATIGUE (Default pure DVS) Is formulated in upper or maximum stress

    Uses original interaction formula for multiaxial loading

    DVS1612_FATIGUE_AMPLITUDE Is formulated in amplitudes rather than upper or maximum stress

    Uses modified interaction formula for better interpretation

    DVS1612_STATIC Performs a static analysis with data defined in EditSetup

    Enhanced DVS1612 Assessment

  • page 7LIMIT Release Noteswww.cae-sim-sol.com

    Modified weld factors in FKM and DVS1612New formulation calculates an effective weld factor depending in thetype of effective stress formulation and on the different weld factorsdepending stress type and sign and weld parameters.

    Empirical effective weld stress according FKM: V = SQRT[S_2^2+T^2]

    Empirical effective weld stress weighted by weld factors awV_aw= SQRT[(S_2/aw)^2+(T/awt)^2]

    Effektive weld factor:aw_eff = V_aw/V

    Static Weld Assessment

  • page 8LIMIT Release Noteswww.cae-sim-sol.com

    New Interface to SolidWorksModel information and results can be selected and exported for the strength assessments in LIMIT

    Currently SWX version 2015 is supported. If other versions are needed, please contact LIMIT support for further information.

    SolidWorks

  • page 9LIMIT Release Noteswww.cae-sim-sol.com

    User Programmed Python ModulesUser defined modules are located in the directory….\LIMIT-CAE-RELEASE-2016\user_imports

    Source of Report Generator is included in this version and can be modified by users. For further information contact the LIMIT support!

    Customization

  • page 10LIMIT Release Noteswww.cae-sim-sol.com

    Weld Sets at Shell-Solid-Interface Shell Solid Interface usedto define shell weld set.

    Attached outside elements:

    Usage:

    Weld Sets at Shell-Solid-Interface

    Shell Weldset

    Solid

  • page 11LIMIT Release Noteswww.cae-sim-sol.com

    Splitting of WeldsType of weld can be changed locally

    For an existing setup (e.g. PS0001) two new sub-setups are derived:

    PS0001-origin … with original definitions

    PS0001-redefine … with modified data

    Saves time and increases the accuracy

    Splitting of Welds

    Different weld type

  • page 12LIMIT Release Noteswww.cae-sim-sol.com

    Splitting of WeldsMark Setup in SetupManager

    Select regions to separate in the viewport

    Select the Split option in the SetupManager(RMB)

    Define name and editing mode

    Splitting of Welds

  • page 13LIMIT Release Noteswww.cae-sim-sol.com

    Splitting of WeldsMark Setup in SetupManager

    Select regions to separate in the viewport

    Select the Split option in the SetupManager(RMB)

    Define name and editing mode

    Splitting of Welds

  • page 14LIMIT Release Noteswww.cae-sim-sol.com

    Import of FE-Result definitions via text fileOne line per FE Result: Name, Step#, Increment#, Path\Filename

    E.g.: torsion, 1,,D:\work\workshop_1-3_non-welded_shaft\shaft.op2

    Define FE Results by File

  • page 15LIMIT Release Noteswww.cae-sim-sol.com

    Improved stress description in LIMIT-ViewerStress output is activated in the JobManager/Edit

    Stresses shown in Viewer have better description

    Define FE Results by File

  • page 16LIMIT Release Noteswww.cae-sim-sol.com

    New license server Server is installed asa real service

    Client (New):

    Info for user

    Restart of server

    License Server

  • page 17LIMIT Release Noteswww.cae-sim-sol.com

    New interface versions:Ansys: 162, 170

    Abaqus: 2016 (Version 6161)

    Interfaces

  • page 18LIMIT Release Noteswww.cae-sim-sol.com

    Last slide

    Release Notes 2016