listing constructional data report...

27
Listing Constructional Data Report (CDR) Report Number HZ12070036-001 Original Issued: 20-Jul-2012 Revised: None Standard(s) Applicant Manufacturer Address Address Country Country Contact Contact Phone Phone FAX FAX Email Email [email protected] [email protected] No.5 Wan gong chi Road,Xiao dong Industrial Zone, Yuyao City, Ningbo, Zhejiang 0574-62502598 0574-62502598 No.5 Wan gong chi Road,Xiao dong Industrial Zone, Yuyao City, Ningbo, Zhejiang China Ningbo Euro Electrical Co.,Ltd. 1.0 Reference and Address Ningbo Euro Electrical Co.,Ltd. 0574-62502596 Richard Gan Richard Gan China 0574-62502596 Portable Electric Luminaires – ANSI/UL 153(12th Ed, rev. March 24, 2011) Portable Luminaires – CSA C22.2 No.12-1982 (R2008) Page 1 of 27

Upload: others

Post on 25-Apr-2020

30 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Listing Constructional Data Report (CDR)exinlight.com.au/wp-content/uploads/2014/07/ETL-Report-IN2400L.pdf · Listing Constructional Data Report (CDR) Report Number HZ12070036-001

Listing Constructional Data Report (CDR)

Report Number HZ12070036-001 Original Issued: 20-Jul-2012 Revised: None

Standard(s)

Applicant Manufacturer

Address Address

Country CountryContact ContactPhone PhoneFAX FAXEmail Email [email protected]@euronb.com

No.5 Wan gong chi Road,Xiao dongIndustrial Zone, Yuyao City, Ningbo,Zhejiang

0574-62502598 0574-62502598

No.5 Wan gong chi Road,Xiao dongIndustrial Zone, Yuyao City, Ningbo,Zhejiang

China

Ningbo Euro Electrical Co.,Ltd.

1.0 Reference and Address

Ningbo Euro Electrical Co.,Ltd.

0574-62502596

Richard Gan Richard GanChina

0574-62502596

Portable Electric Luminaires – ANSI/UL 153(12th Ed, rev. March 24, 2011)Portable Luminaires – CSA C22.2 No.12-1982 (R2008)

Page 1 of 27

Page 2: Listing Constructional Data Report (CDR)exinlight.com.au/wp-content/uploads/2014/07/ETL-Report-IN2400L.pdf · Listing Constructional Data Report (CDR) Report Number HZ12070036-001

Report No. HZ12070036-001Ningbo Euro Electrical Co.,Ltd.

Page 2 of 27 Issued: 20-Jul-2012Revised: None

ProductBrand name

ModelsModel SimilarityRatingsOther Ratings NA

N/AInput: 12-24Vdc, 3,0A; Output: 12VDC, 20W

DescriptionThe product covered by this report is portable luminaire with LED lighting and rechargeablebattery. The battery shall be assembled with product and its charger shall be provided.IN2400L

2.0 Product Description

Luminaire, PortableSmith Light

ED 16.3.15 (8-Jan-10) Mandatory

Page 3: Listing Constructional Data Report (CDR)exinlight.com.au/wp-content/uploads/2014/07/ETL-Report-IN2400L.pdf · Listing Constructional Data Report (CDR) Report Number HZ12070036-001

Report No. HZ12070036-001Ningbo Euro Electrical Co.,Ltd.

Page 3 of 27 Issued: 20-Jul-2012Revised: None

Photo 1 - Overview

Photo 2 - Overview

3.0 Product Photographs

01

ED 16.3.15 (8-Jan-10) Mandatory

Page 4: Listing Constructional Data Report (CDR)exinlight.com.au/wp-content/uploads/2014/07/ETL-Report-IN2400L.pdf · Listing Constructional Data Report (CDR) Report Number HZ12070036-001

Report No. HZ12070036-001Ningbo Euro Electrical Co.,Ltd.

Page 4 of 27 Issued: 20-Jul-2012Revised: None

3.0 Product Photographs

Photo 3 - Overview

Photo 4 - Overview

01

ED 16.3.15 (8-Jan-10) Mandatory

Page 5: Listing Constructional Data Report (CDR)exinlight.com.au/wp-content/uploads/2014/07/ETL-Report-IN2400L.pdf · Listing Constructional Data Report (CDR) Report Number HZ12070036-001

Report No. HZ12070036-001Ningbo Euro Electrical Co.,Ltd.

Page 5 of 27 Issued: 20-Jul-2012Revised: None

3.0 Product Photographs

Photo 5 - Overview

Photo 6 - Construction

01

01

ED 16.3.15 (8-Jan-10) Mandatory

Page 6: Listing Constructional Data Report (CDR)exinlight.com.au/wp-content/uploads/2014/07/ETL-Report-IN2400L.pdf · Listing Constructional Data Report (CDR) Report Number HZ12070036-001

Report No. HZ12070036-001Ningbo Euro Electrical Co.,Ltd.

Page 6 of 27 Issued: 20-Jul-2012Revised: None

3.0 Product Photographs

Photo 7 - Construction

Photo 8 - Construction

ED 16.3.15 (8-Jan-10) Mandatory

Page 7: Listing Constructional Data Report (CDR)exinlight.com.au/wp-content/uploads/2014/07/ETL-Report-IN2400L.pdf · Listing Constructional Data Report (CDR) Report Number HZ12070036-001

Report No. HZ12070036-001Ningbo Euro Electrical Co.,Ltd.

Page 7 of 27 Issued: 20-Jul-2012Revised: None

3.0 Product Photographs

Photo 9 - Construction

Photo 10 - Construction

01

01

02

02

ED 16.3.15 (8-Jan-10) Mandatory

Page 8: Listing Constructional Data Report (CDR)exinlight.com.au/wp-content/uploads/2014/07/ETL-Report-IN2400L.pdf · Listing Constructional Data Report (CDR) Report Number HZ12070036-001

Report No. HZ12070036-001Ningbo Euro Electrical Co.,Ltd.

Page 8 of 27 Issued: 20-Jul-2012Revised: None

3.0 Product Photographs

Photo 11 - Construction (Battery)

Photo 12 - Construction

01

02

01

ED 16.3.15 (8-Jan-10) Mandatory

Page 9: Listing Constructional Data Report (CDR)exinlight.com.au/wp-content/uploads/2014/07/ETL-Report-IN2400L.pdf · Listing Constructional Data Report (CDR) Report Number HZ12070036-001

Report No. HZ12070036-001Ningbo Euro Electrical Co.,Ltd.

Page 9 of 27 Issued: 20-Jul-2012Revised: None

3.0 Product Photographs

Photo 13 - Construction

Photo 14 - Construction

01

ED 16.3.15 (8-Jan-10) Mandatory

Page 10: Listing Constructional Data Report (CDR)exinlight.com.au/wp-content/uploads/2014/07/ETL-Report-IN2400L.pdf · Listing Constructional Data Report (CDR) Report Number HZ12070036-001

Report No. HZ12070036-001Ningbo Euro Electrical Co.,Ltd.

Page 10 of 27 Issued: 20-Jul-2012Revised: None

3.0 Product Photographs

Photo 15 - Construction (LED control circuit)

Photo 16 - Construction (LED control circuit)

01

02

01

ED 16.3.15 (8-Jan-10) Mandatory

Page 11: Listing Constructional Data Report (CDR)exinlight.com.au/wp-content/uploads/2014/07/ETL-Report-IN2400L.pdf · Listing Constructional Data Report (CDR) Report Number HZ12070036-001

Report No. HZ12070036-001Ningbo Euro Electrical Co.,Ltd.

Page 11 of 27 Issued: 20-Jul-2012Revised: None

3.0 Product Photographs

Photo 17 - Construction

Photo 18 - Construction

01

ED 16.3.15 (8-Jan-10) Mandatory

Page 12: Listing Constructional Data Report (CDR)exinlight.com.au/wp-content/uploads/2014/07/ETL-Report-IN2400L.pdf · Listing Constructional Data Report (CDR) Report Number HZ12070036-001

Report No. HZ12070036-001Ningbo Euro Electrical Co.,Ltd.

Page 12 of 27 Issued: 20-Jul-2012Revised: None

3.0 Product Photographs

Photo 19 - Construction

Photo 20 - Battery charger

01

02

01

ED 16.3.15 (8-Jan-10) Mandatory

Page 13: Listing Constructional Data Report (CDR)exinlight.com.au/wp-content/uploads/2014/07/ETL-Report-IN2400L.pdf · Listing Constructional Data Report (CDR) Report Number HZ12070036-001

Report No. HZ12070036-001Ningbo Euro Electrical Co.,Ltd.

Page 13 of 27 Issued: 20-Jul-2012Revised: None

Photo #

Item

no.1Name

Manufacturer/

trademark2 Type / model2Technical data and securementmeans

Mark(s) of

conformity3

1 1 EnclosureCHI MEICORPORATION

PA-757(+)ABS, yellow, 80°C, minimum4,0mm thick (UL/E56070)

cURus

5 1 Intenal enclosureCHI MEICORPORATION

PA-757(+)ABS, yellow, 80°C, minimum4,0mm thick (UL/E56070)

cURus

3 1Transparentlampshade

CHI MEICORPORATION

PC-110(+)PC, V-2, 105°C, minimum 1,5mmthick (UL/E56070)

cURus

6 1Flexible cablebetween controlgear and battery

YUYAO XUANHUIELECTRIC COLTD

SJT300V, 105°C, 18AWG, with screwgland (UL/E322683)

cULus

14 1Internal wirebetween LED andcontrol circuit

YUYAO RIYUEWIRE & CABLEINDUSTRY COLTD

1015600V, 80°C, 22AWG, Soldering(UL/E256446)

cULus

9 1Internal wirebetween batteryand charger

YUYAO RIYUEWIRE & CABLEINDUSTRY COLTD

1015600V, 80°C, 22AWG, Soldering(UL/E256446)

cULus

12 1 ButtonDAILYWELLELECTRONICSCO LTD

Q13120 V, 5A, 60°C(UL/E187490)

cURus

12 2 SwitchLIGHT COUNTRYCO LTD

R19A-0125 V, 2A, 65°C(UL/E104190)

cURus

19 1 Reflect boardCHI MEICORPORATION

PA-757(+)ABS, yellow, 80°C, minimum1,5mm thick (UL/E56070)

cURus

19 2 PCB for LED array

HESHAN DONGLIELECTRONICTECHNOLOGIESCO LTD

EPAV-0, 180°C, minimum 1,5mm thick(UL/E318223)

cURus

18 1Transparent coverfor encasing heatsink

CHI MEICORPORATION

PC-110(+)PC, V-2, 105°C, minimum 1,5mmthick (UL/E56070)

cURus

15 1 ConnectorFUJIAN SHANYASWITCH CO LTD

FSE1011V-0, 105°C, WireRange:12-28 AWG (UL/E305884)

cURus

15 2 TerminalCIXI KEFAELECTRONICSCO LTD

KF126 (3)250V, 8A, WireRange:14-26 AWG (UL/E306245)

cURus

16 1PCB for controlcircuit

KINGBOARDLAMINATESHOLDINGS LTD

KB-2150GV-0, 105°C, minimum 1,8mm thick(UL/E123995)

cURus

10 2Heat shrinkabletube

SHENZHENWOER HEAT-SHRINKABLEMATERIAL COLTD

RSFR-H 600V, 125°C (UL/E203950) cURus

10 1 Fuse

SHENZHENLANSONELECTRONICSCO LTD

5D 125V, 5A (UL/E221465) cURus

9 2

11 1

20 1 ChargerFUYUANELECTRONIC COLTD

FY1503000Input:100-240V~, 50/60Hz, 80VAoutput:15Vdc, 3A (UL/E304160)

cURus

4.0 Critical Components

Battery

SHANGHAIHONGBEIPOWER SYSTEMCO LTD

FM/BB127,FM/BB1210,FM/BB1218

12V7AH, 12V10AH, 12V18AH(UL/MH46345)

cURus

ED 16.3.15 (8-Jan-10) Mandatory

Page 14: Listing Constructional Data Report (CDR)exinlight.com.au/wp-content/uploads/2014/07/ETL-Report-IN2400L.pdf · Listing Constructional Data Report (CDR) Report Number HZ12070036-001

Report No. HZ12070036-001Ningbo Euro Electrical Co.,Ltd.

Page 14 of 27 Issued: 20-Jul-2012Revised: None

Photo #

Item

no.1Name

Manufacturer/

trademark2 Type / model2Technical data and securementmeans

Mark(s) of

conformity3

4.0 Critical Components

3) Indicates specific marks to be verified, which assures the agreed level of surveillance for the component. "NR" - indicates Unlisted andonly visual examination is necessary. "See 5.0" indicates Unlisted components or assemblies to be evaluated periodically refer to section5.0 for details.

NOTES:

1) Not all item numbers are indicated (called out) in the photos, as their location is obvious.

2) “Various“ means any type, from any manufacturer that complies with the "Technical data and securement means" and meets the "Mark(s)of conformity" can be used.

ED 16.3.15 (8-Jan-10) Mandatory

Page 15: Listing Constructional Data Report (CDR)exinlight.com.au/wp-content/uploads/2014/07/ETL-Report-IN2400L.pdf · Listing Constructional Data Report (CDR) Report Number HZ12070036-001

Report No. HZ12070036-001Ningbo Euro Electrical Co.,Ltd.

Page 15 of 27 Issued: 20-Jul-2012Revised: None

No Unlisted CEC components are used in this report.

5.0 Critical Unlisted CEC Components

ED 16.3.15 (8-Jan-10) Mandatory

Page 16: Listing Constructional Data Report (CDR)exinlight.com.au/wp-content/uploads/2014/07/ETL-Report-IN2400L.pdf · Listing Constructional Data Report (CDR) Report Number HZ12070036-001

Report No. HZ12070036-001Ningbo Euro Electrical Co.,Ltd.

Page 16 of 27 Issued: 20-Jul-2012Revised: None

2. Mechanical Assembly - Components such as switches, fuseholders, connectors, wiring terminals and displaylamps are mounted and prevented from shifting or rotating by the use of lockwashers, starwashers, or othermounting format that prevents turning of the component.

3. Corrosion Protection - All ferrous metal parts are protected against corrosion by painting, plating or theequivalent.

4. Accessibility of Live Parts - All uninsulated live parts in primary circuitry are housed within a non-metallicenclosure constructed with no openings other than those specifically described in Sections 4 and 5.

5. Grounding - None6. Polarized Connection - None7. Internal Wiring - Internal wiring is routed away from sharp or moving parts. Internal wiring leads terminating

in soldered connections are made mechanically secure prior to soldering. Recognized Componentseparable (quick disconnect) connectors of the positive detent type, closed loop connectors, or other typesspecifically described in the text of this report are also acceptable as internal wiring terminals. At pointswhere internal wiring passes through metal walls or partitions, the wiring insulation is protected againstabrasion or damage by plastic bushings or grommets. All wiring is minimum 22AWG with a minimum ratingof 600V, 80°C.

8. Schematics - Refer to Illustration 1 for schematics requiring verification during Field RepresentativeInspection Audits.

9. Markings - The product is marked on as labeling system as described of Section as follows: <manufacturer'sname, brand name, model number, date of manufacturer, electrical ratings>.

10. Cautionary Markings -The following are required: refer to Illustration 2 - Label for details11. Installation, Operating and Safety Instructions - Instructions for installation and use of this product are

provided by the manufacturer. Refer to Illustration 3- Instruction for details.

1. Spacing - In primary circuits, 6,4 mm minimum spacing are maintained through air and over surfaces ofinsulating material between current-carrying parts of opposite polarity and 9,5mm minimum between suchcurrent-carrying parts and dead-metal parts or low voltage isolated circuits.

Listed Component - A component part, which has been previously Listed or Certified by an accreditedCertification Organization with no restrictions and is used in the intended application within its ratings.

Critical Features/Components - An essential part, material, subassembly, system, software, or accessory of aproduct that has a direct bearing on the product’s conformance to applicable requirements of the productstandard.Construction Details - For specific construction details, reference should be made to the photographs anddescriptions. All dimensions are approximate unless specified as exact or within a tolerance. In addition to thespecific construction details described in this Report, the following general requirements also apply.

Recognized Component - A component part, which has been previously evaluated by an accredited certificationbody with restrictions and must be evaluated as part of the basic product considering the restrictions as specifiedby the Conditions of Acceptability.

6.0 Critical Features

Unlisted Component - A part that has not been previously evaluated to the appropriate designated componentstandard. It may also be a Listed or Recognized component that is being used outside of its evaluated Listing orcomponent recognition.

ED 16.3.15 (8-Jan-10) Mandatory

Page 17: Listing Constructional Data Report (CDR)exinlight.com.au/wp-content/uploads/2014/07/ETL-Report-IN2400L.pdf · Listing Constructional Data Report (CDR) Report Number HZ12070036-001

Report No. HZ12070036-001Ningbo Euro Electrical Co.,Ltd.

Page 17 of 27 Issued: 20-Jul-2012Revised: None

Illustration 1 - LED control circuit

7.0 Illustrations

ED 16.3.15 (8-Jan-10) Mandatory

Page 18: Listing Constructional Data Report (CDR)exinlight.com.au/wp-content/uploads/2014/07/ETL-Report-IN2400L.pdf · Listing Constructional Data Report (CDR) Report Number HZ12070036-001

Report No. HZ12070036-001Ningbo Euro Electrical Co.,Ltd.

Page 18 of 27 Issued: 20-Jul-2012Revised: None

7.0 Illustrations

ED 16.3.15 (8-Jan-10) Mandatory

Page 19: Listing Constructional Data Report (CDR)exinlight.com.au/wp-content/uploads/2014/07/ETL-Report-IN2400L.pdf · Listing Constructional Data Report (CDR) Report Number HZ12070036-001

Report No. HZ12070036-001Ningbo Euro Electrical Co.,Ltd.

Page 19 of 27 Issued: 20-Jul-2012Revised: None

7.0 Illustrations

Illustration 2 - Label

Model:IN2400L

Lamp rating:Input :12-24VDC, 3,0AOutput: 12VDC, 20WDate:

Ningbo Euro Electrical Co.,LtdNo.5 Wan gong chi Road,Xiao dong Industrial Zone, Yuyao City, Ningbo, Zhejiang, China

CONFORMS TO ANSI/UL STD 153CERTIFIED TO CSA STD C22.2 No.12

4005288

WARNING:--"RISK OF ELECTRIC SHOCK" or "RISQUE DE CHOC ÉLECTRIQUE"--"CAUTION – RISK OF FIRE" or "ATTENTION – RISQUE D’INCENDIE"--"DISCONNECT POWER BEFORE SERVICING" or "COUPER L’ALIMENTATION AVANT L’ENTRETIEN"

ED 16.3.15 (8-Jan-10) Mandatory

Page 20: Listing Constructional Data Report (CDR)exinlight.com.au/wp-content/uploads/2014/07/ETL-Report-IN2400L.pdf · Listing Constructional Data Report (CDR) Report Number HZ12070036-001

Report No. HZ12070036-001Ningbo Euro Electrical Co.,Ltd.

Page 20 of 27 Issued: 20-Jul-2012Revised: None

7.0 Illustrations

Illustration 3- Instruction

ED 16.3.15 (8-Jan-10) Mandatory

Page 21: Listing Constructional Data Report (CDR)exinlight.com.au/wp-content/uploads/2014/07/ETL-Report-IN2400L.pdf · Listing Constructional Data Report (CDR) Report Number HZ12070036-001

Report No. HZ12070036-001Ningbo Euro Electrical Co.,Ltd.

Page 21 of 27 Issued: 20-Jul-2012Revised: None

7.0 Illustrations

Contact DetailsNingbo Euro Electrical Co.,Ltd.No.5 Wan gong chi Road,Xiao dong Industrial Zone, Yuyao City, Ningbo, Zhejiang, China

ED 16.3.15 (8-Jan-10) Mandatory

Page 22: Listing Constructional Data Report (CDR)exinlight.com.au/wp-content/uploads/2014/07/ETL-Report-IN2400L.pdf · Listing Constructional Data Report (CDR) Report Number HZ12070036-001

Report No. HZ12070036-001Ningbo Euro Electrical Co.,Ltd.

Page 22 of 27 Issued: 20-Jul-2012Revised: None

7.0 Illustrations

ED 16.3.15 (8-Jan-10) Mandatory

Page 23: Listing Constructional Data Report (CDR)exinlight.com.au/wp-content/uploads/2014/07/ETL-Report-IN2400L.pdf · Listing Constructional Data Report (CDR) Report Number HZ12070036-001
Page 24: Listing Constructional Data Report (CDR)exinlight.com.au/wp-content/uploads/2014/07/ETL-Report-IN2400L.pdf · Listing Constructional Data Report (CDR) Report Number HZ12070036-001

Report No. HZ12070036-001Ningbo Euro Electrical Co.,Ltd.

Page 24 of 27 Issued: 20-Jul-2012Revised: None

BASIC LISTEEAddressCountryProduct

MULTIPLE LISTEE 1AddressCountry

Brand Name

ASSOCIATEDMANUFACTURER

AddressCountry

BASIC LISTEE MODELS

MULTIPLE LISTEE 2AddressCountry

Brand Name

ASSOCIATEDMANUFACTURER

AddressCountry

BASIC LISTEE MODELS

MULTIPLE LISTEE 3AddressCountry

Brand Name

ASSOCIATEDMANUFACTURER

AddressCountry

BASIC LISTEE MODELS

None

None

None

MULTIPLE LISTEE 1 MODELS

MULTIPLE LISTEE 3 MODELS

MULTIPLE LISTEE 2 MODELS

Luminaire, PortableChina

9.0 Correlation Page For Multiple ListingsThe following products, which are identical to those identified in this report except for model number and Listeename, are authorized to bear the ETL label under provisions of the Intertek Multiple Listing Program.

Ningbo Euro Electrical Co.,Ltd.No.5 Wan gong chi Road,Xiao dong Industrial Zone, Yuyao City, Ningbo, Zhejiang

ED 16.3.15 (8-Jan-10) Mandatory

Page 25: Listing Constructional Data Report (CDR)exinlight.com.au/wp-content/uploads/2014/07/ETL-Report-IN2400L.pdf · Listing Constructional Data Report (CDR) Report Number HZ12070036-001

Report No. HZ12070036-001Ningbo Euro Electrical Co.,Ltd.

Page 25 of 27 Issued: 20-Jul-2012Revised: None

10.0 General InformationThe Applicant and Manufacturer have agreed to produce, test and label ETL Listed products in accordance withthe requirements of this Report. The Manufacturer has also agreed to notify Intertek and to request authorizationprior to using alternate parts, components or materials.

COMPONENTSComponents used shall be those itemized in this Intertek report covering the product, including any amendments

LISTING MARKThe ETL Listing mark applied to the products shall either be separable in form, such as labels purchased fromIntertek, or on a product nameplate or other media only as specifically authorized by Intertek. Use of the mark is

MANUFACTURING AND PRODUCTION TESTSManufacturing and Production Tests shall be performed as required in this Report.

FOLLOW-UP SERVICEPeriodic unannounced audits of the manufacturing facility (and any locations authorized to apply the mark) shallbe scheduled by Intertek. An audit report shall be issued after each visit. Special attention will be given to thefollowing:

1. Conformance of the manufactured product to the descriptions in this Report.2. Conformance of the use of the ETL mark with the requirements of this Report and the Certification Agreement.3. Manufacturing changes.4. Performance of specified Manufacturing and Production Tests.

In the event that the Intertek representative identifies non-conformance(s) to any provision of this Report, theApplicant shall take one or more of the following actions:

1. Correct the non-conformance.2. Remove the ETL Mark from non-conforming product.3. Contact the issuing product safety evaluation center for instructions.

10.1 Evaluation of Unlisted Components

Note to Intertek Follow Up Inspector: The Component Evaluation Center, CEC, will notify you in writingwhen these components must be selected and sent to the CEC for re-evaluation

Ship the samples to:Intertek Testing Services Shanghai LimitedETL Component Evaluation CenterBuilding No. 86, 1198 Qinzhou Road (North)Shanghai 200233, ChinaAttn: Ms. Dansy XuSample Disposition: Due to the destructive nature of the testing, all samples will bediscarded at the conclusion of testing unless, the manufacturer specifically requests thereturn of the samples. The request for return must accompany the initial componentshipment.

Because Unlisted Components are uncontrolled, and they do not fall under a third party follow up program,Intertek may require these components to be tested and/or evaluated at least once annually, more often forcertain components, as part of the independent certification process. The Unlisted Components in Section 5.0require testing and/or evaluation as indicated.

ED 16.3.15 (8-Jan-10) Mandatory

Page 26: Listing Constructional Data Report (CDR)exinlight.com.au/wp-content/uploads/2014/07/ETL-Report-IN2400L.pdf · Listing Constructional Data Report (CDR) Report Number HZ12070036-001

Report No. HZ12070036-001Ningbo Euro Electrical Co.,Ltd.

Page 26 of 27 Issued: 20-Jul-2012Revised: None

Product Test Voltage Test TimeAll products covered by this Report. 1000V 60 s

or1200V 1 s

Test Equipment

The test equipment shall incorporate a transformer with an essentially sinusoidal output, a means to indicate theapplied test potential, and an audible and/or visual indicator of dielectric breakdown.

Method

The test voltage specified below shall be applied between primary circuits and accessible dead-metal parts. Thetest voltage may be gradually increased to the specified value but must be maintained at the specified value forone second or one minute as required.

One hundred percent of production of the products covered by this Report shall be subjected to a routineproduction line dielectric withstand test.

The test shall be conducted on products, which are fully assembled. Prior to applying the test potential, allswitches, contactors, relays, etc., should be closed so that all primary circuits are energized by the test potential.If all primary circuits cannot be tested at one time, then separate applications of the test potential shall be made.

If the rated output of the test equipment is 500VA or more, the applied test potential may be indicated by either:1 - a voltmeter in the primary circuit;2 - a selector switch marked to indicate the test potential; or3 - a marking in a readily visible location to indicate the test potential for test equipment having a single testpotential output.In cases 2 and 3, the test equipment shall include a lamp or other visual means to indicate that the test potentialis present at the test equipment output. All test equipment shall be maintained in current calibration.

Products Requiring Dielectric Voltage Withstand Test:

The test equipment shall incorporate a voltmeter in the output circuit to indicate directly the applied test potentialif the rated output of the test equipment is less than 500VA.

Dielectric Voltage Withstand Test

11.1 Dielectric Voltage Withstand Test

11.0 Manufacturing and Production TestsThe manufacturer agrees to conduct the following Manufacturing and Production Tests as specified:

Required Tests

ED 16.3.15 (8-Jan-10) Mandatory

Page 27: Listing Constructional Data Report (CDR)exinlight.com.au/wp-content/uploads/2014/07/ETL-Report-IN2400L.pdf · Listing Constructional Data Report (CDR) Report Number HZ12070036-001

Report No. HZ12070036-001Ningbo Euro Electrical Co.,Ltd.

Page 27 of 27 Issued: 20-Jul-2012Revised: None

Date/ Project Handler/Proj # Site ID Reviewer

None

12.0 Revision SummaryThe following changes are in compliance with the declaration of Section 8.1:

Section Item Description of Change