local space housing association - hamcltd.comhamcltd.com/sors.pdf · item schedule rate i ......

325
LOCAL SPACE HOUSING ASSOCIATION PROVISION OF RESPONSIVE REPAIRS AND MAINTENANCE SERVICE Schedule of Rates THIS IS A CONTRACT DOCUMENT

Upload: vuduong

Post on 14-Feb-2018

220 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE HOUSING ASSOCIATION

PROVISION OF RESPONSIVE REPAIRS AND

MAINTENANCE SERVICE

Schedule of Rates

THIS IS A CONTRACT DOCUMENT

Page 2: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

1 Local Space Housing

STANDARD ABBREVIATIONS USED IN THE LOCAL SPACE SCHEDULE OF RATES DESCRIPTIONS

It should be noted that the following information is provided as guidance only, and not all items may be covered.

(BOT) Bottom (BS) Both Sides (OS) One Side 2L Two layer 3L Three layer A Amp AA Anodised aluminium AC Alternating current BASEC British Approvals Service for Cables BCC British Coal Corporation BCMC British Cable Manufacturers Confederation BF Both faces BS British Standard Btu British thermal unit BWF British Woodworking Federation CA Client Representative CCTV Closed circuit television CCU Consumer control unit CI Cast Iron CLG Ceiling CM Cubic metres CORGI Council for Registered Gas Installers CP Chromium Plated CT/ct Coat CWST Cold water storage tank DC Direct current dia diameter DIR Direct DP Double Pole dpc Damp proof course dpm Damp proof membrane EC7 Economy 7 EP Ethylene propylene EPDM Ethylene Propylene Diene Monomer F&E Feed and expansion FL&B Framed, ledged and braced FLR Floor GC Gas chimney GRP Glass fibre reinforced polyester GWCG Georgian wired cast glass GWPP Georgian wired polished plate HO Home Office HOFR Heat, oil and flame retardant horizon horizontal HP High performance HR ) Hr ) Half round or hour depending on context hr ) HRC High rupturing cartridge

Page 3: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

2 Local Space Housing

HT Height HTR Heater HW Hardwood IEE Institute of Electrical Engineers IND Indirect IT Per Item i.e. comprising the whole of the works as detailed KG Kilogram Kw Kilowatts L Layer(s) L&B Ledged and braced LM/M Linear metres LTR Litres LV Low voltage MCB Miniature circuit breaker MDF Medium density fibreboard MICC Mineral insulated copper cable MM Millimetres MS Mild steel ne not exceeding NICEIC National Inspection Council for Electrical Installation Contracting NS Natural stone OCC Occupancy PCC/pcc Precast concrete PM Purpose Made PVC Polyvinyl Chloride PVCU/PVCu Unplasticised Polyvinyl Chloride RCD Residual current device RS Reconstructed stone SAA Satin anodised aluminium SEC Security SM Square metres STD Standard SW Softwood T and E Twin and earth T, G and V Tongued, grooved and V jointed TV Television UPVC Unplasticised Polyvinyl Chloride V Volts W Watt WC/wc Water closet WH Wash hand WHB Wash hand basin WP/wp Waterproofing

Page 4: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

3 Local Space Housing

MEASUREMENT RULES The rules for the measurement of items included in this Schedule of Rates will be those detailed within the All Trade Preambles and this Appendix as follows: .1 For items in the Schedule of Rates which are measured (indicated in LM/SM/CM), the Client will

reimburse the Service Provider for works on the following basis. The use of an item and the usage rate is less than 1 (one) the charge shall be as for 1 (one)

whole. Where however, more than 1 (one) whole is used reimbursement shall be pro-rata the item schedule rate i.e. 1.27 LM, SM, or CM = 1.27 to two decimal places, (multiplied) by the unit schedule rate.

.2 For Items in the Schedule of Rates where the Unit of Measure is per No. (Number) or IT (Item),

then the charge shall be as for 1 (one) whole multiplied by the unit schedule rate. .3 For Items in the Schedule of Rates where the Unit of Measure is per HR (Hour) then the charge

shall be to two decimal places, recorded to the nearest 15 mins, irrespective of whether more or less than 1 (one) whole i.e. 0.50, 1.25 etc., multiplied by the unit schedule rate.

Specific rules for the measurement of scaffolding, only where reimbursable by operation of the provisions contained in the Addendum to the Client’s Requirements on Operational Matters - Scaffolding, Trestles, Hoardings, Barriers, Ladders etc, are as follows: .1 General scaffolding is designated in ranges of girth and height. The girth shall mean the

horizontal length measured along the face of the structure to which access is required. The height shall mean the vertical height measured from average scaffold base plate level to the upper surface of the top working platform. In the case of a scaffolding with top working platforms at differing levels the average height shall be used.

.2 Scaffold towers is itemised and designated by vertical height irrespective of plan dimensions. The

height shall mean the vertical height measured from the tower base plates/wheels as appropriate to the upper surface of the top working platform. The items are deemed to include for providing towers of any suitable dimensions to suit access available.

.3 Chimney scaffolding is itemised and designated by height above ground level, irrespective of the

girth. The height shall mean the vertical height measured from ground level to the upper surface of the working platform.

.4 Working platforms to general scaffolding are deemed to be four boards wide and shall be

measured per linear metres of platform. .5 For any type of scaffolding the additional height above working platforms due to handrails,

screens, gantries and the like is deemed to be included.

Page 5: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

4 Local Space Housing

MEASUREMENT PREAMBLES The following are provided as indicative examples only and should be reviewed and adapted as necessary by the Client, prior to incorporation into any tender or other Contract documentation, to ensure that they are fully compatible with the maintenance service to be provided and the particular Schedule of Rates with which they are to be used. Generally Rates Deemed to Include A. Rates for all Schedule of Rates items in all trades generally are deemed to include as appropriate for the

following: .1 All work that can reasonably be deemed to be included either as good workmanship, including

the provision of materials and plant, or accepted practice whether or not specifically referred to in this document, the Client Representative’s decision on this will be final.

.2 Clearing away all arisings, redundant materials, debris, rubbish etc., from site including damping

down to reduce dust, loading into skips at ground level, skip hire or equivalent, transport and landfill and other waste disposal charges including any recycling costs. .

.3 Scaffolding, staging, towers, hoists, cradles and access ladders etc., as required up to and

including second storey eaves level above ground level (including chimneys, gables, dormers and the like to two storey structures and below), including maintaining in accordance with appropriate safety regulations, clearing away on completion and making good all work damaged or disturbed.

.4 Temporary supports, shoring or hoarding to existing structure including maintaining, adapting

and clearing away on completion and making good all work damaged or disturbed. .5 Temporary dustproof, weatherproof and security screens, etc., as required complete with doors

including maintaining, adapting and clearing away on completion and making good all work damaged or disturbed.

.6 All setting and marking out. .7 Taking up any necessary boarding, de-nailing timbers, relaying boarding and punching in nail

heads. .8 Taking off and re-fixing gutters, downpipes, TV/radio aerials, satellite dishes, electricity, TV,

British Telecom cables and the like to facilitate the renewal or repair of any component. .9 Removing all screws, nails, plugs and the like associated with the removal of any item.

.10 Setting aside, storing, cleaning and subsequently re-fixing items described as re-fixed.

.11 Setting aside, protecting and reinstating tenants’ goods, chattels, fixtures, fittings and other property and clearing roof space where necessary to undertake the works ordered.

.12 Fixing to any surface with nails, screws, blocks, glue, bolts etc., as required including drilling,

packing and scribing.

Page 6: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

5 Local Space Housing

.13 Jointing or finishing new materials to existing. .14 Matching all materials to existing. .15 Making good existing structure, finishings etc., as necessary. .16 Protecting the whole of the works.

.17 Seeking the approvals of the Client and or Client Representative in respect of any Works including any reasonable waiting or other down time whilst awaiting approval.

The Service Provider is to allow in his tender for any additional costs that he considers may be necessary.

Page 7: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

6 Local Space Housing

Scaffolding Rates Deemed to Include A. Rates for scaffolding are additionally deemed to include as appropriate for the following: .1 Basing out, preparing and levelling of ground, provision of additional support, base plates,

spreaders and the like as necessary. .2 Protection of the structure fabric, finishings, roof coverings and the like. .3 Provision of all requisite tubes and fittings of every description, delivery, handling and removal. .4 Erecting, supporting, maintaining, adapting and dismantling as required. .5 Bridging across structures and all other obstructions where necessary.

.6 Removal, temporary storage/resiting, protection and subsequent reinstatement as required of all TV, radio and telecommunication aerials, satellite dishes and the like.

.7 Fans, gantries, hoardings, sheeting and double boarding of working platforms to afford

protection around/over entrances, paths, rights of way and other forms of access or thoroughfare.

.8 Working platforms to towers and chimney scaffolding. .9 Toe boards, guard-rails, handrails, safe ladder access, ladders, brickguards, elevational debris

netting/sheeting and the like. .10 Ancillary plant and equipment such as tower feet/wheels, out-riggers, cross bracing, gin wheels,

ropes and the like. .11 Lighting and/or alarming where deemed necessary or appropriate and/or as specifically directed

by the Client Representative. .12 Protection against lighting strike.

.13 Fixed handholds and physical ties to the structure where necessary, subsequent removal and making good.

.14 Provision of certified structural design calculations and erection certificates to the Client

Representative where required under the Contract. .15 Reinstatement of ground and making good any damaged surfacing and/or pavings if necessary.

The Service Provider is to allow in his tender for any additional costs that he considers may be necessary.

Page 8: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

7 Local Space Housing

Excavation and Earthwork Rates Deemed to Include A. Rates for excavation and earthwork are additionally deemed to include as appropriate for the following: .1 Clearing all site vegetation, lifting turf for preservation, storing, maintaining and subsequently

preparing ground, relaying and watering and application of weedkiller. .2 Grubbing up vegetation, roots, uncharted drains and services, etc., that may be encountered. .3 Working in or next to existing buildings. .4 Working next to public footpaths, roads and the like.

.5 Working next to or around existing services, maintaining and protecting as required. .6 Levelling and compacting formation level, backfilling and compacting selected material and

disposal of all surplus excavated material from site. .7 Excavating by hand or mechanical means, no additional cost will be entertained if it is found that

the proposed method is impractical. .8 Multiple handling of excavated material.

.9 Breaking up any material encountered including concrete, brickwork, stonework or rock.

.10 Earthwork support including everything necessary to uphold the sides of the excavations. .11 Allowances for working space as necessary to accommodate formwork, brickwork, rendering,

tanking or similar work including additional excavation, earthwork support, backfilling and disposal.

.12 Blinding surfaces of hardcore beds and filling to excavations with approved fine material.

.13 Disposal of ground and surface water, including by pumping if necessary. .14 Temporary barriers, watching and lighting.

The Service Provider is to allow in his tender for any additional costs that he considers may be necessary.

Page 9: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

8 Local Space Housing

Demolition Rates Deemed to Include A. Rates for demolition are additionally deemed to include as appropriate for the following: .1 Adequate strutting, propping and other protection to maintain stability of adjacent structures or

parts of structures both during and after completion of demolition works. .2 Removal of all insitu and applied finishings in conjunction with the taking down of all structural

and non-structural walls, partitions and the like. .3 Removal of all timbers, fixtures and fittings including stripping out all associated cleats, bearers

and fillets and withdrawing all plugs and all subsequent making good to finishes disturbed. .4 Watering to prevent nuisance by dust. .5 Cutting out, cutting back and plugging off as appropriate any redundant piping, tubing, conduit,

wires, bars etc., encountered during any demolition works. .6 Extending finishings, decorations, skirtings, picture rails, cornices and the like into or over newly

formed or infilled openings. .7 Draining down and subsequent refilling of any heating or water services necessary in conjunction

with demolition works being undertaken. .8 Disconnecting all mechanical and electrical services and temporary diverting and reconnecting of

same or capping off at a suitable location to leave the existing installations in a safe working order.

.9 Giving the required notices to Local Authorities, gas water or electricity companies and

complying with any specific instruction from them.

The Service Provider is to allow in his tender for any additional costs that he considers may be necessary.

Page 10: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

9 Local Space Housing

Fencing and Gates Rates Deemed to Include A. Rates for fencing and gates are additionally deemed to include as appropriate for the following: .1 Clearing all site vegetation, lifting turf for preservation, storing, maintaining and subsequently

preparing ground, relaying and watering and application of weedkiller. .2 Grubbing up vegetation, roots, uncharted drains and services, etc., that may be encountered. .3 Working next to existing buildings. .4 Working next to public footpaths, roads and the like.

.5 Working next to or around existing services, maintaining and protecting as required. .6 Levelling, compacting, grading and shaping formation level, backfilling and compacting selected

material and disposal of all surplus excavated material from site. .7 Excavating by hand or mechanical means, no additional cost will be entertained if it is found that

the proposed method is impractical. .8 Multiple handling of excavated material.

.9 Breaking up any material encountered including concrete, brickwork, stonework or rock.

.10 Earthwork support including everything necessary to uphold the sides of the excavations. .11 Allowances for working space as necessary to accommodate formwork, brickwork, rendering,

tanking or similar work including additional excavation, earthwork support, backfilling and disposal.

.12 Disposal of ground and surface water, including by pumping if necessary.

.13 Excavation, concrete, backfilling etc of all post holes in any materials. .14 Setting out and alignment of all fencing.

.15 Joining/jointing new sections of fencing to existing and abutments with structure.

.16 Using pressure impregnated timber. .17 Applied preservative treatment coatings as finishing. .18 Framing together timber gates with mortice and tenon joints. .19 All labour, materials, fixing or hanging, glue, nails, screws, plugs, and everything necessary for

the proper completion of the works. .20 Fixing with nails unless otherwise instructed. .21 Framing up, welding, drilling, bolts, nuts and fabrication and fixing of metal gates. .22 All other relevant items covered by other sections of the measurement preambles to the

Schedule of Rates generally.

The Service Provider is to allow in his tender for any additional costs that he considers may be necessary.

Page 11: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

10 Local Space Housing

Drainage Rates Deemed to Include A. Rates for drainage are additionally deemed to include as appropriate for the following: .1 Clearing all site vegetation, lifting turf for preservation, storing, maintaining and subsequently

preparing ground, relating and watering and application of weedkiller. .2 Excavation by hand or machine as necessary and appropriate for the location of the work. .3 Working in or next to existing buildings. .4 Working next to public footpaths, roads and the like.

.5 Working next to or around existing services, maintaining and protecting as required. .6 Levelling and compacting formation level, backfilling and compacting selected material and

disposal of all surplus excavated material from site.

.7 Earthwork support including everything necessary to uphold the sides of the excavations. .8 Allowances for working space as necessary for formwork, brickwork, rendering, tanking or similar

work including additional excavation, earthwork support, backfilling and disposal. .9 Blinding surfaces of hardcore beds and filling to excavations with approved fine material. .10 Disposal of ground and surface water.

.11 Breaking up and removing concrete, brickwork, blockwork, rock and other obstructions. .12 Sulphate resisting cement where required. .13 Formwork and temporary support to concrete where required. .14 Temporary diversion of existing drains, maintaining flow and subsequently reinstating on

completion of the works. .15 Stopping off ends of redundant drains. .16 Jointing new drains to existing. .17 Vertical expansion boards to concrete surrounds at pipe joints. .18 Coring, cleaning and flushing all drains, gullies and manholes etc., on completion. .19 Testing all drainage, commissioning and providing all certificates required by the relevant

authorities, bodies or the Client.

The Service Provider is to allow in his tender for any additional costs that he considers may be necessary.

Page 12: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

11 Local Space Housing

Concrete Work Rates Deemed to Include A. Rates for concrete work are additionally deemed to include as appropriate for the following: .1 Sulphate resisting cement where required.

.2 Ordinary and fair face formwork and temporary supports to all concrete where required. .3 Filling into or on to formwork and well tamping around reinforcement. .4 Tamped, trowelled or any other surface finish to concrete beds etc. .5 Forming all holes, mortices, chases and the like. .6 Rolling margins on all reinforcing bar. .7 Cutting, bending or forming reinforcement to required shape and for all hooks, tying wire,

spacers, chairs and the like. .8 Reinforcement to cast insitu concrete (where require0 and all precast concrete. .9 Laps, tying wire and temporary supports to fabric reinforcement. .10 Provision of a polythene DPC laid on sand blinding for all internal solid floor constructions or

repairs, whether specifically stated or not. .11 Welted and sealed laps to damp-proof membranes. .12 Lintels, cills and the like including the provision of all cast-in fixing blocks, slips or strips as

required. .13 Bedding precast concrete lintels, padstones etc., in cement or cement lime mortar and pointing

as required.

.14 Provision of all cast-in fixing blocks, slips or strips required by other trades into cast insitu and precast components.

.15 Provision of hand or machine mixed concrete as appropriate to the nature and circumstances of

work being undertaken.

The Service Provider is to allow in his tender for any additional costs that he considers may be necessary.

Page 13: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

12 Local Space Housing

Brickwork and Blockwork Rates Deemed to Include A. Rates for brickwork and blockwork are additionally deemed to include as appropriate for the following: .1 All rough and fair cutting.

.2 Forming rough and fair grooves, throats, mortices, chases, rebates and holes, stops and mitres. .3 Raking out joints and hacking faces to form key for finishings. .4 Labour in eaves filling. .5 Centering to new and rebuilt flat or cambered arches. .6 Building against other surfaces/finishes where required. .7 Building overhand where required. .8 Bonding to any other work including additional materials. .9 Constructing work in any bond. .10 Additional fixing cramps, ties etc., as required. .11 Finishing fair face and pointing with any type of joint as required. .12 Labour and facing to returns, ends and angles to copings, cills and the like. .13 Forming cavities between skins of hollow walls including stainless steel ties and insulation as

required. .14 Cutting, pinning and wedging load bearing work to soffits of existing work.

.15 Extending plaster, decorations, skirtings etc., where any openings filled in or cut through existing walls.

.16 Laps to damp-proof courses and membranes and bedding in cement mortar.

The Service Provider is to allow in his tender for any additional costs that he considers may be necessary.

Page 14: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

13 Local Space Housing

Woodwork Rates Deemed to Include A. Rates for woodwork are additionally deemed to include as appropriate for the following: .1 Levelling, packing and adjusting to present a perfectly level, even and true frame or backing. .2 All labours, grounds, battens, packings, noggins, cleats, holes, bolts, etc., and treating cut ends

with brush applied preservative to structural timbers. .3 All grounds, battens, noggins and the like and for all necessary packing and adjustment to

present a perfectly level, even and true frame or backing. .4 Taking off and renewing defective battens, bituminous felt underlays and vapour barriers where

replacing roof or weatherboarding. .5 Ends, angles, mitres, scribing and other labours for all items of woodwork. .6 All necessary, cover strips. .7 Taking down and refixing as required bath panels, duct casings, support framework to bath

panels and duct casings etc. .8 All bearers and fixings to any surface. .9 Splicings, piecing in and all making good in repairing and overhauling or replacing doors,

windows, frames, ironmongery and the like. .10 Mastic pointing to external door or window frames. .11 Dovetail and scarfed joints, notchings and fitting ends of timbers to metal sections, shoes and

heads, trimming floor joists, ceiling joists and rafters to openings for hearths, chimneys, trap doors and the like.

.12 Blocking, dowelling, pelleting and gluing and any additional labours required in relation to

staircase or similar item repairs. .13 Sheet backing to kitchen units. .14 Notching, cutting holes, scribing etc., to ducts, kitchen worktops, fittings and the like. .15 Sealant at junction of worktops, vanity unit tops and adjacent wall finishes. .16 Fitting new ironmongery to all new external doors or refitting existing as specified, including all

necessary parts and fixings so as to be fully operational. .17 Pre-priming or factory priming all finished timber and joinery (irrespective of whether standard

or purpose made) and painting two undercoats and one gloss oil colour finishing coats following installation of the work whether described in the Schedule of Rates descriptions or not.

.18 Unless specified otherwise, sourcing all new ironmongery to match existing removed so far as is

practicable. .19 Overhauling ironmongery is to include for taking off, dismantling, renewing any defecting parts,

oiling as required, assembling and refixing with new screws or fixings to leave in perfect working order.

Page 15: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

14 Local Space Housing

Woodwork Rates Deemed to Include A. Rates for woodwork are additionally deemed to include as appropriate for the following: (cont’d) .20 Overhauling, easing and adjusting doors, windows etc., is to include for all repairs required to

the complete door or window and their associated frames, linings, architraves, stops etc., and not just one repair. The work includes for taking off all ironmongery, carrying out all repairs to the item, easing and adjusting the door or window to fit its frame or lining, fully repairing or if specified renewing all ironmongery, including oiling to leave the whole item to be repaired in full and good working order.

.21 Rates for ironmongery generally include for fitting and fixing, including cutting, sinking, boring,

morticing etc., lubricating and adjusting all locks, catches, etc., and all making good as required. .22 The rates for all new doors includes for either supplying the doors to the exact size or cutting

down a larger door to suit the existing frame or lining size, including the provision and adaptation of door blanks where necessary. No extra payment will be made due to difficulties in accurately fitting any door to existing linings.

.23 Rates for all doors and windows shall include for framing, studding, packing, sticking, screwing,

cramping, welding, glazing and all materials not specifically mentioned, but required to make and fix the whole to work perfect.

The Service Provider is to allow in his tender for any additional costs that he considers may be necessary.

Page 16: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

15 Local Space Housing

Metalwork Rates Deemed to Include A. Rates for metalwork are additionally deemed to include as appropriate for the following: .1 Welding, riveting, drilling and tapping etc., including provision of fixing components such as

rivets, bolts, rag bolts, rawl bolts, screws and the like, together with all nuts, washers etc., as required.

.2 Sealant pointing around screens, fixtures and other situations wherever appropriate. .3 Priming and painting two undercoats and one gloss finishing coat of oil colour on all new

metalwork to match existing decorations. .4 Overhauling, easing and adjusting doors, etc., is to include for all repairs required to the

complete door and its associated frame and not just one repair. The work includes for taking off all ironmongery, carrying out all repairs to the item, easing and adjusting to fit its frame or lining, fully repairing or if specified renewing all ironmongery including oiling to leave the whole item to be repaired in full and working order.

.5 Rates for grab bars, grab rails, shower curtains, shower head riser rails and all like accessories

are deemed to include for provision of all necessary brackets, flanges, pattresses and similar items where specifically stated or not in Schedule of Rates descriptions.

The Service Provider is to allow in his tender for any additional costs that he considers may be necessary.

Page 17: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

16 Local Space Housing

Finishings Rates Deemed to Include A. Rates for finishings are additionally deemed to include as appropriate for the following: .1 Work to flat, sloping or vertical surfaces. .2 Hacking existing surfaces to provide a key for new work. .3 Applying finishes to any background surface. .4 Preparing backgrounds to receive any finish, such as dry brushing off to remove all loose

particles, dust and efflorescence, washing off any grease and mould oil, hacking, raking out joints in brick and blockwork, wetting and rewetting surfaces, appliocation of all priming solutions/coats, all to ensure that an adequate bond between the background and adhesive, plaster or any other finish is obtained.

.5 Making good of all damaged sub-floors and other surfaces in preparation to receive any applied

finishes, including application of proprietary self levelling latex cement compound where necessary.

.6 All dubbing out to walls or ceilings as required to provide the correct levels and to maintain

planes with existing surrounding plasterwork, making fair joints between new plasterwork and existing surrounding plasterwork.

.7 Fair joints to existing finishes. .8 Working or cutting and fitting any finishings around all pipes, electrical fittings, appliances, into

rebates in frames, around openings, protections, and all like components, fittings, obstructions or voids, including any additional making good necessary.

.9 De-nailing existing timbers and providing all necessary battens or noggins to support edges and

joints of plasterboard. .10 Cement and sand backing, adhesive, special tiles, narrow widths, jointing and grouting to any

tiling work. .11 Latex screed to new floor finishes to obtain correct levels. .12 All work in narrow widths, patches and the like irrespective of the size or girth. .13 Cutting of metric floor, wall or ceiling tiles where required to replace imperial sized equivalents or

vice versa

.14 Priming, pre-caulking, scrimming, caulking and all other preparatory treatment relevant to surfaces to receive decorative finishes.

The Service Provider is to allow in his tender for any additional costs that he considers may be necessary.

Page 18: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

17 Local Space Housing

Painting and Decorating Rates Deemed to Include A. Rates for painting and decorating are additionally deemed to include as appropriate for the following: .1 Preparation of surfaces and the requisite type and number of paint coatings to be in accordance

with the manufacturer’s recommendations and/or these preambles, which ever constitutes the highest performance specification.

.2 Work on any surface or surface finish whatsoever encountered. .3 Cutting in around glazing and other finishes. .4 Work in multicolours and cutting to line. .5 Work in staircase areas, plant rooms etc. .6 Work on all opening edges of windows, doors etc. .7 Taking off and refixing ironmongery on completion. .8 Matt or vinyl silk finish emulsion paint as directed. .9 Eggshell or gloss oil colour paint as directed. .10 Priming coat to all new metalwork. .11 Work includes all narrow widths and patches irrespective of the girth or size. .12 All rubbing down and preparation of wall surfaces and for sizing walls prior to hanging wall or

lining paper. .13 Hanging of wall or lining paper strictly in accordance with the manufacturer’s instructions. .14 Protection of all furniture and fittings, the provision of dust sheets and the removal of items such

as curtains etc., prior to commencing the works, together with the rehanging or reinstatement of the same.

The Service Provider is to allow in his tender for any additional costs that he considers may be necessary.

Page 19: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

18 Local Space Housing

Glazing Rates Deemed to Include A. Rates for glazing are additionally deemed to include as appropriate for the following: .1 Any size pane. .2 Irregular size or shape of panes. .3 Replacement of all breakages of new or existing glass including whilst cutting out for or fitting

window moulded extractor/ventilation fans and the like fittings. .4 Taking off and refixing or renewing wood or metal beads. .5 Taking off and rebedding or renewing washleather strips, rubber seals and the like. .6 Sealing or priming all rebates and backs of beads prior to inserting/fixing glazing. .6 Glazing compound, gaskets, sprigs, clips or other fixing materials. .7 Obscured glass is to be Artic or similar to match existing. .8 Patterned glass is to match existing. .9 Aligning patterned or wired glass and matching all materials to existing. .10 All work to be undertaken in accordance with the current Building Regulations Approved

Document L as appropriate by FENSA registered operatives.

The Service Provider is to allow in his tender for any additional costs that he considers may be necessary.

Page 20: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

19 Local Space Housing

Plumbing and Heating Rates Deemed to Include A. Rates for plumbing and heating are additionally deemed to include as appropriate for the following: .1 Stripping out redundant or defective pipework, fittings and the like not specifically referred to in

the priced Schedule of Rates descriptions. .2 Cutting or forming holes, mortices, chases and the like in the existing structure and making good

all work disturbed. .3 Renewing, installing or repairing any valves, taps, cocks, fittings, sanitaryware and the like shall

include for shutting any external or internal valves to isolate the relevant circuit or sub-circuit and draining any residual water from the circuit or sub-circuit pipework.

.4 Draining down any or part of any water services installations and subsequently refilling, venting

adjusting and setting temperature and controls. .5 Removing and subsequently replacing or renewing insulation, access panels, floor boarding,

shelving and the like in order to gain access to the work. .6 Extending, altering and adapting existing pipework to suit any new work including all directional

changes, providing any additional pipework, fittings or other materials required. .7 All fittings, angles, ends, stop ends, swannecks, outlets, brackets, clips, spacers, etc., all joints

and connections including adaptors, joints to existing and to drains. .8 Knotting, priming, stopping, filling and painting two undercoats and one gloss finishing coat of oil

colour on all new woodwork replaced in connection with this section to match existing decoration.

.9 Priming and painting two undercoats and one gloss finishing coat of oil colour on all new

exposed pipework or radiators to match existing decorations. .10 Labelling pipe runs, valves, stopcocks and other similar fittings. .11 Items of sanitaryware include for all accessories such as overflow, waste, chains, plugs etc.,

sealing joints between fitting and adjacent surfaces with a neat bend of anti-mould jointing silicone, and leaving the fitting in pristine condition and full working order.

.12 Cleaning of all sanitaryware and other fittings, upon completion to remove all marks and leave in

a pristine condition.

.13 Removal of all swarf and foreign matter from storage tanks, cisterns, cylinders and the like on completion, thoroughly flushing throughout to clean and resetting any valves, ballvalves and the like to ensure correct water level.

.14 Installing, repairing or renewing cisterns, tanks and cylinders and the like include where

appropriate for the transfer of any functional electric immersion heater from the existing to new component.

.15 Rates for grab bars, grab rails, shower curtains, shower head riser rails and all like accessories

are deemed to include for provision of all necessary brackets, flanges, pattresses and similar items where specifically stated or not in Schedule of Rates descriptions.

Page 21: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

20 Local Space Housing

Plumbing and Heating Rates Deemed to Include A. Rates for plumbing and heating are additionally deemed to include as appropriate for the following

(Cont’d) .16 Overhauling any item is to include for removing, dismantling and replacing any work or

defective part, greasing or oiling where appropriate, reassembling to leave in perfect working order and refixing.

.17 Earthing and bonding all plumbing and associated metalwork in conjunction with Schedule items

whether specifically stated or not in Schedule of Rates descriptions. .18 Testing all services, fittings, appliances, etc., commissioning and providing all certificates

required by the relevant gas, water or electrical authorities, bodies or the Client.

The Service Provider is to allow in his tender for any additional costs that he considers may be necessary.

Page 22: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

21 Local Space Housing

Electrical Installation Rates Deemed to Include A. Rates for electrical work are additionally deemed to include as appropriate for the following: .1 Stripping out redundant or defective cables, conduits, fittings and the like, not specifically

referred to in the priced Schedule of Rates descriptions. .2 Stripping out, builder’s work and the like associated with complete with re-wiring of existing

properties. .3 Where necessary, the removal and reinstating of electrical voltage supply by appropriate

supply/service provider to facilitate the progression of works. Service Provider to arrange attendance and pay all charges incurred in connection with supply/service provider’s work.

.4 Draining down, refilling, venting, adjusting and setting controls in connection with repairs or

replacement of cylinder heater elements and the like. .5 Renewal of equipment includes for disconnecting and removing old equipment supplying and

fixing new equipment specified and connecting to adjacent outlet point. Should a new outlet point be required it shall be deemed to be included.

.6 Cutting or forming holes, mortices, chases and the like in the existing structure and making good

all work disturbed. .7 Adjusting and setting controls. .8 Removing and subsequently replacing or renewing insulation, access panels, floor boarding,

shelving and the like in order to gain access to the works. .9 Removal and reinstating of lids, covers, accessories, equipment, locating junction boxes,

withdrawing or disconnecting old cables, threading new cables through old conduits or providing and fixing new conduits/mini trunking complete shall be deemed to be included in rates for wiring.

.10 Altering and adapting existing installation to suit any new work including providing any additional

cables, fittings or other materials required. .11 Preparing new or existing fittings and supplying and connecting all cables, screws, clips and

accessories. .12 Providing and fixing blank plates as necessary to fuse boards and outlets. .13 Rates for Consumer Control Units (CCU’s) are deemed to include for providing and fixing fuses,

miniature circuit breakers (mcb’s), blany way plates, residual current device (rcd) and the like. .14 Providing and fixing new backboxes, pattresses, earth fly leads and other items normally

associated with any fitting being renewed. .15 Reusing existing conduit, trunking etc., where possible. .16 Supply and fixing new cable, conduit and trunking where not possible to use existing cable,

conduit and trunking is to include dressing, bends, angles, conduit boxes, outlets and all other accessories and fixings.

Page 23: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

22 Local Space Housing

Electrical Installation Rates Deemed to Include A. Rates for electrical work are additionally deemed to include as appropriate for the following: (cont’d) .17 Overhauling any item is to include for removing, dismantling and replacing any worn or defective

part, greasing or oiling where appropriate, reassembling to leave in perfect working order and refixing.

.18 Priming and painting two coats oil colour on new exposed conduit to match existing.

.19 Earthing and bonding all plumbing and associated metalwork in conjunction with Schedule of

Rates items whether specifically stated or not in Schedule of Rates descriptions. .20 Inspection and testing of all services, fittings, appliances etc., when completed to ensure

satisfactory functional operation and safety, including temporary supply, commissioning and providing all certificates (including test results) required by the relevant electrical authorities, bodies or the Client.

The Service Provider is to allow in his tender for any additional costs that he considers may be necessary.

Page 24: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

1 Local Space Housing

FOUNDATIONS ............................................................................................................ 1 Floor - Concrete Internal Renewal ........................................................................................................ 1 Floor - Concrete Internal New .............................................................................................................. 1 Foundations in Trenches ..................................................................................................................... 1

GROUNDWORKS .......................................................................................................... 2 Kerbs, Channels and Edgings .................................................................................................................. 2

Kerbs - Precast Concrete ..................................................................................................................... 2 Channels - Precast Concrete ................................................................................................................ 2 Edgings - Precast Concrete .................................................................................................................. 2 Edgings - Timber ................................................................................................................................ 3

Paths and Pavings .................................................................................................................................. 3 Paving - Insitu Concrete ...................................................................................................................... 3 Paving - Coated Macadam ................................................................................................................... 3 Paving - Precast Concrete Flag ............................................................................................................. 4 Paving - Brick ..................................................................................................................................... 4 Paving - Gravel ................................................................................................................................... 5 Paving - Temporary Repairs ................................................................................................................. 5 Hardcore ............................................................................................................................................ 5

Steps, Stairs and Ramps ......................................................................................................................... 5 Steps, Stairs and Ramps - Insitu and Precast Concrete .......................................................................... 5

Metal Stairs and Walkways and Balustrades ............................................................................................. 6 Balustrades - Isolated ......................................................................................................................... 6 Handrails - Associated ......................................................................................................................... 6 Balustrades and Handrails - Sundry Repairs .......................................................................................... 6

Miscellaneous Fittings ............................................................................................................................. 7 Clothes Lines ...................................................................................................................................... 7 Signs ................................................................................................................................................. 8 Bollards .............................................................................................................................................. 8 Garden Sheds ..................................................................................................................................... 8 Coal Bunkers ...................................................................................................................................... 9

FENCING AND GATES................................................................................................. 11 Fencing ............................................................................................................................................... 11

Fencing - Boarded ............................................................................................................................. 11 Fencing - Chestnut Pale ..................................................................................................................... 12 Fencing - Interwoven and Overlap Fence Panels ................................................................................. 13 Fencing - Chainlink ........................................................................................................................... 14 Fencing - Garden Rail ........................................................................................................................ 15 Fencing - Hit and Miss ....................................................................................................................... 15 Fencing - Palisade ............................................................................................................................. 16 Fencing - Post and Rail ...................................................................................................................... 16 Fencing - Post and Wire .................................................................................................................... 17 Fencing - Concrete Panel ................................................................................................................... 17 Fencing - Sundry Repairs ................................................................................................................... 17 Fencing - Posts ................................................................................................................................. 18 Fencing - Timber Gates ..................................................................................................................... 19 Fencing - Metal Gates ....................................................................................................................... 20 Fencing - Gate Posts ......................................................................................................................... 21

DRAINAGE ................................................................................................................. 22 Drainage Below Ground ........................................................................................................................ 22

Drainage - New - Clay Pipes .............................................................................................................. 22 Drainage - New - Plastic Pipes ........................................................................................................... 22 Drainage - Existing - Repairs .............................................................................................................. 22 Gullies .............................................................................................................................................. 23 Extra Over for Breaking Out and Reinstatement .................................................................................. 24

Manholes ............................................................................................................................................. 24 Manholes - Brick ............................................................................................................................... 24 Inspection Chambers - Polypropylene ................................................................................................. 24 Manhole - Covers and Slabs ............................................................................................................... 25

Clearing Blockages, CCTV and Testing ................................................................................................... 26 Clearing Blockages ............................................................................................................................ 26 CCTV Drains ..................................................................................................................................... 26

Page 25: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

2 Local Space Housing

Drain Testing .................................................................................................................................... 26 Land Drainage and Soakaways .............................................................................................................. 26

Land Drainage .................................................................................................................................. 26 Soakaways ....................................................................................................................................... 27

BRICKWORK .............................................................................................................. 28 Brick/Block Walling ............................................................................................................................... 28

Walls - Demolition ............................................................................................................................. 28 Walls - Construction .......................................................................................................................... 28 Walls - Rebuilding ............................................................................................................................. 29 Piers ................................................................................................................................................ 30 Brick/Block Repairs ........................................................................................................................... 31 Repointing ........................................................................................................................................ 32 Tell Tales ......................................................................................................................................... 32 Cavities ............................................................................................................................................ 32 Openings - Minor .............................................................................................................................. 32 Openings - Internal Door ................................................................................................................... 32 Openings - External Door/Window ..................................................................................................... 33 Lintols and Arches ............................................................................................................................. 35 Cills and Thresholds .......................................................................................................................... 35 Copings ............................................................................................................................................ 36 Damp Proof Courses ......................................................................................................................... 37 Anti-Fungicide Treatment .................................................................................................................. 37

Airbricks and Vents ............................................................................................................................... 38 Airbricks ........................................................................................................................................... 38 Ventilators ........................................................................................................................................ 38

Chimneys............................................................................................................................................. 39 Chimney Stacks ................................................................................................................................ 39 Flue Sundries.................................................................................................................................... 40 Chimney Pots, Caps, Cowls Etc. ......................................................................................................... 41

Meter Cupboards .................................................................................................................................. 42 Gas/Electric Meter Cupboards ............................................................................................................ 42

Fireplaces ............................................................................................................................................ 42 Fire Surrounds and Hearths ............................................................................................................... 42 Fire Openings etc .............................................................................................................................. 44 Fire Parts ......................................................................................................................................... 45 Cookers (Rayburn or Similar) ............................................................................................................. 46

MASONRY.................................................................................................................. 47 Natural Stone ................................................................................................................................... 47 Reconstructed Stone ......................................................................................................................... 47 Stone Repairs ................................................................................................................................... 48

ROOFING .................................................................................................................. 50 Clay/Concrete Roof Tiling ...................................................................................................................... 50

Concrete Interlocking Roof Tiles to Match Existing ............................................................................... 50 Concrete or Clay Plain Tiles to Match Existing ..................................................................................... 50 Concrete or Clay Verges .................................................................................................................... 51 Concrete or Clay Bedded Ridges, Hips and Valley Tiles ........................................................................ 51 Dry Verge, Ridge and Hip Tiles .......................................................................................................... 52 Roof Ventilation ................................................................................................................................ 52

Slate Roofing ....................................................................................................................................... 53 Fibre Cement Slating ......................................................................................................................... 53 Natural Slating .................................................................................................................................. 53 Fibre Cement Slating - Ridge, Verge and Hips Tiles ............................................................................. 53

Vertical Coverings ................................................................................................................................. 54 Vertical Tile Hanging ......................................................................................................................... 54 Vertical Fibre Cement Slating ............................................................................................................. 54

Sheet Roofing ...................................................................................................................................... 55 Sheet Roof Coverings ........................................................................................................................ 55

Remedial Works ................................................................................................................................... 56 Liquid Applied Waterproof Roof Covering ............................................................................................ 56 Inspections....................................................................................................................................... 56 Temporary Repairs............................................................................................................................ 56

Page 26: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

3 Local Space Housing

Sundry Items .................................................................................................................................... 57 Felt Roofing ......................................................................................................................................... 57

Felt Roofing - Two Layer ................................................................................................................... 57 Felt Roofing - Three Layer ................................................................................................................. 59

Asphalt Roofing .................................................................................................................................... 60 Asphalt Roof Coverings ..................................................................................................................... 60

Sundry Works ...................................................................................................................................... 61 Loft Insulation .................................................................................................................................. 61 Roof Boarding .................................................................................................................................. 61

Leadwork ............................................................................................................................................. 62 Lead Roof Coverings and Flashings - Code 4 ....................................................................................... 62

CARPENTRY AND JOINERY ......................................................................................... 64 Floors, Roofs and Partitions ................................................................................................................... 64

Floors .............................................................................................................................................. 64 Wall or Partitions .............................................................................................................................. 65 Wall Plates ....................................................................................................................................... 66 Roof Members .................................................................................................................................. 66 Joist Hangers .................................................................................................................................... 66

Fascia, Soffit and Bargeboards .............................................................................................................. 67 Fascias, Soffit and Bargeboards - Timber ............................................................................................ 67 Fascias, Soffits and Bargeboards - PVCu ............................................................................................. 67

Rainwater Gutters - Timber ................................................................................................................... 68 Flooring ............................................................................................................................................... 68

Flooring - Rigid Sheet - WPB Plywood ................................................................................................. 68 Flooring - Rigid Sheet - Flooring Grade Chipboard ............................................................................... 69 Flooring - Rigid Sheet - Hardboard ..................................................................................................... 69 Flooring - Timber Board .................................................................................................................... 69 Flooring - Wood Block ....................................................................................................................... 70

External Cladding ................................................................................................................................. 70 Cladding - Timber Weatherboarding - Shiplap ..................................................................................... 70 Cladding - Timber Weatherboarding - Feather Edge ............................................................................ 70 Cladding - Timber Weatherboarding - Softwood Tongued, Grooved and V Jointed ................................. 71 Cladding - Plastic Profiled Sheet Cladding - Shiplap .............................................................................. 71

Windows ............................................................................................................................................. 71 Windows - Casement - Standard Softwood Double Glazed ................................................................... 71 Windows - Casement - Purpose Made Softwood Double Glazed ............................................................ 72 Windows - Box Sash - Purpose Made Softwood Double Glazed ............................................................. 73 Windows - Horizontal Pivot Hung - Purpose Made Softwood Double Glazed ........................................... 73 Windows - Casement - Standard Hardwood Double Glazed .................................................................. 73 Windows - Casement - Purpose Made Hardwood Double Glazed ........................................................... 74 Windows - Box Sash - Purpose Made Hardwood Double Glazed ............................................................ 75 Windows - Horizontal Pivot Hung - Purpose Made Hardwood................................................................ 75 Windows - Feature - Softwood ........................................................................................................... 75 Windows - Feature - Hardwood .......................................................................................................... 76 Window and Door Frames - Combination - Softwood ........................................................................... 76 Window and Door Frames - Combination - Hardwood .......................................................................... 76 Windows - Horizontal Pivot Hung - Purpose Made PVCu ....................................................................... 76 Windows - Casement - Purpose Made PVCu ........................................................................................ 77 Windows - Tilt and Turn - Purpose Made PVCu.................................................................................... 78 Window and Door Frames - Combination - PVCu ................................................................................. 78 Windows - Single Glazing .................................................................................................................. 79 Windows - Timber - Repairs............................................................................................................... 79 Timber Window Repairs - Compounds ................................................................................................ 81 Windows - Metal - Timber Sub-Frame................................................................................................. 82 Windows - Metal - Repairs ................................................................................................................. 82 Windows - Aluminium - Repairs ......................................................................................................... 83 Windows - PVCu - Repairs ................................................................................................................. 83 Windows PVCu - Overhaul ................................................................................................................. 85 Windows and Door Frames - Silicone Pointing ..................................................................................... 87 Windows - Roof ................................................................................................................................ 87 Windows - Roof - Repairs .................................................................................................................. 88

External Doors ..................................................................................................................................... 88

Page 27: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

4 Local Space Housing

Doors - External Panelled or Glazed - Hardwood - Standard ................................................................. 88 Doors - External Panelled or Glazed - Hardwood - Purpose Made .......................................................... 88 Doors - External Panelled or Glazed - Softwood - Standard .................................................................. 89 Doors - External Panelled or Glazed - Softwood - Purpose Made ........................................................... 89 Doors - External - High Performance .................................................................................................. 90 Doors - External - Firecheck Flush ...................................................................................................... 90 Doors - External Matchboard - Softwood ............................................................................................ 91 Doors - External - PVCu Residential Type ............................................................................................ 91 Doors - External - High Performance PVCu Residential Type ................................................................. 92 Doors - External - Repairs - Timber .................................................................................................... 92 Doors - External - Repairs - PVCu ....................................................................................................... 94 Doors - External - Galvanised Steel (Crittall Type) ............................................................................... 95 Doors - External - Aluminium ............................................................................................................. 95

Internal Timber Doors .......................................................................................................................... 95 Doors - Internal - Flush ..................................................................................................................... 95 Doors - Internal - Framed .................................................................................................................. 96 Doors - Internal – Firecheck .............................................................................................................. 96 Doors - Internal - Repairs - Timber .................................................................................................... 97

Door Frames and Linings ...................................................................................................................... 98 Door Frames - External - Timber ........................................................................................................ 98 Door Frames - External - High Performance ........................................................................................ 98 Door Frames - Water Bars ................................................................................................................. 99 Door and Window Frames - Draughtproofing Strips and Sections .......................................................... 99 Door Frames, Linings and Casings - Internal - Timber ......................................................................... 100 Door Frame - Repairs - Timber ......................................................................................................... 100 Door Stops - Softwood ..................................................................................................................... 101 Door Frames - Intumescent Strips and Smoke Seals ........................................................................... 102

Garage Doors and Frames .................................................................................................................... 102 Door - Garage - Matchboard - Softwood ............................................................................................ 102 Doors - Garage - Renewals - Up and Over Metal ................................................................................ 102 Doors - Garage - Repairs - Up and Over Metal ................................................................................... 102 Door Frames - Garage - Timber ........................................................................................................ 103

Internal Joinery ................................................................................................................................... 104 Cladding or Linings - Internal Wall .................................................................................................... 104 Staircases ........................................................................................................................................ 104 Handrails ......................................................................................................................................... 105

Miscellaneous Fixtures/Fittings ............................................................................................................. 106 Stool for Hot Water Cylinder ............................................................................................................. 106 Tank Stands .................................................................................................................................... 106 Hat and Coat Rails ........................................................................................................................... 107 Curtain Battens and Tracks ............................................................................................................... 107

Kitchen Units and Worktops ................................................................................................................. 107 Kitchen Units to match Existing ......................................................................................................... 107 Sink Tops and Sink Base Units .......................................................................................................... 108 Kitchen Units - Clients Standard Specification ..................................................................................... 108 Worktops ........................................................................................................................................ 111 Kitchen Units - Repairs ..................................................................................................................... 112

Wardrobe Units ................................................................................................................................... 113 Fitted Wardrobe - Repairs ................................................................................................................. 113

Skirtings, Rails and Architraves ............................................................................................................. 113 Skirting - Softwood .......................................................................................................................... 113 Picture Rail ...................................................................................................................................... 114 Architraves - Softwood ..................................................................................................................... 114 Thresholds to Door Openings ............................................................................................................ 114 Shelving .......................................................................................................................................... 114 Windowboards ................................................................................................................................. 115 Duct Casings ................................................................................................................................... 115 Bath Panels and Framing .................................................................................................................. 116

Ironmongery ....................................................................................................................................... 117 Butts, Hinges, etc. ........................................................................................................................... 117 Sliding Sash Fittings ......................................................................................................................... 117 Door Closers .................................................................................................................................... 118

Page 28: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

5 Local Space Housing

Floor Springs ................................................................................................................................... 118 Sliding Door Gear ............................................................................................................................. 119 Locks .............................................................................................................................................. 119 Latches ........................................................................................................................................... 120 Cylinder Night Latches ...................................................................................................................... 120 Roller and Ball Catches ..................................................................................................................... 120 Bolts, Security Bolts, Panic Bolts and Padlocks ................................................................................... 121 Fittings to Timber Windows .............................................................................................................. 121 Fittings to Steel Windows ................................................................................................................. 122 Fittings to Aluminium Windows ......................................................................................................... 123 Door Furniture including Viewer, Security Chain ................................................................................. 123 Letterplates ..................................................................................................................................... 124 Door Numerals ................................................................................................................................ 124 Door Stop........................................................................................................................................ 124 Cupboard Handles ........................................................................................................................... 124

Miscellaneous Works............................................................................................................................ 125 Ceiling Access Hatch ........................................................................................................................ 125 Gain Entry ....................................................................................................................................... 125 Boarding Up/Nailing Up .................................................................................................................... 125 Boarding Up Long Term Voids ........................................................................................................... 126

Carpentry and Joinery – Client Inspections ............................................................................................ 127 PLASTERWORK AND OTHER FINISHES ..................................................................... 128

Plasterwork, Rendering and Screeds ..................................................................................................... 128 Plasterwork - Walls .......................................................................................................................... 128 Plasterboard - Walls ......................................................................................................................... 129 Plasterwork - Ceilings ....................................................................................................................... 129 Plasterboard - Ceilings ...................................................................................................................... 130 Plasterwork Repairs and Sundry Items .............................................................................................. 131 Sand and Cement Render ................................................................................................................. 132 Render Repairs and Sundry Items ..................................................................................................... 133 Coatings to Ceilings.......................................................................................................................... 133 Dry Lining ....................................................................................................................................... 134 Plaster Coving ................................................................................................................................. 134 Floor Screeds................................................................................................................................... 135

WALL AND FLOOR TILE AND SHEET FINISHES .......................................................... 136 Wall and Floor Finishes ........................................................................................................................ 136

Wall Tiling ....................................................................................................................................... 136 Floor Tiles - Quarry Tiles .................................................................................................................. 137 Skirtings - Quarry Tiles ..................................................................................................................... 138 Floor Tiles - Ceramic Tiles ................................................................................................................. 138 Skirtings - Ceramic ........................................................................................................................... 139 Floor Tiles - Vinyl ............................................................................................................................. 140 Sheet Flooring ................................................................................................................................. 141 'Polysafe' Flooring ............................................................................................................................ 141 Skirtings - Plastic, Vinyl, Lino or Rubber ............................................................................................. 142 Contract Grade Carpeting ................................................................................................................. 143 Nosings ........................................................................................................................................... 143

PAINTING AND DECORATING ................................................................................... 144 Preparation - External and Internal ....................................................................................................... 144

Works Prior to Painting ..................................................................................................................... 144 Preparation - General Surfaces.......................................................................................................... 144 Preparation - External Walls .............................................................................................................. 144

External Decoration ............................................................................................................................. 144 Masonry [Smooth or Textured] Paint - External Walls ......................................................................... 144 Oil Paint - External Metalwork ........................................................................................................... 145 Metalshield Paint - External Metalwork .............................................................................................. 146 Metalshield paint - Existing External Metalwork - Two Coat ................................................................. 147 Oil Paint - External Woodwork .......................................................................................................... 149 Oil Paint - Existing External Woodwork - Two Coat ............................................................................. 150 Oil Paint - Existing External Woodwork - Three Coat ........................................................................... 150 Decorative Wood Protection - External Woodwork .............................................................................. 151

Page 29: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

6 Local Space Housing

Cuprinol Trade - External Woodwork ................................................................................................. 151 Internal Decoration ............................................................................................................................. 152

Wash Down ..................................................................................................................................... 152 Strip Polystyrene Ceiling Tiles ........................................................................................................... 152 Patch Repairs .................................................................................................................................. 152 Paintwork to Ceiling, Walls, Woodwork .............................................................................................. 153 Paintwork to Ceiling, Walls, Washdown Woodwork ............................................................................. 154 Paintwork to Ceilings Only ................................................................................................................ 155 Strip Paper ...................................................................................................................................... 155 Strip Painted Paper .......................................................................................................................... 156 Ceiling Finishes - Alternatives ............................................................................................................ 157 Wall Finishes - Alternatives ............................................................................................................... 159 Internal Paintwork - Complete Dwellings............................................................................................ 161 Internal Paintwork and Washdown - Complete Dwellings .................................................................... 162 Work to Room Heights above 3.00m ................................................................................................. 164

CLEANING AND CLEARANCE ..................................................................................... 165 Internal Cleaning and Clearance........................................................................................................ 165 External Clearance ........................................................................................................................... 165 Disposal of Previous Tenants Rubbish ................................................................................................ 166 External Communal Clearance .......................................................................................................... 166

External Garden Clearance and Works .................................................................................................. 167 Turfing ............................................................................................................................................ 167 Shrubs ............................................................................................................................................ 167 Hedges ........................................................................................................................................... 167 Trees .............................................................................................................................................. 167 Fence Lines ..................................................................................................................................... 168 Environmental Domestic Waste Clearance .......................................................................................... 168 Environmental Communal Waste Clearance ....................................................................................... 169 Carpet Cleaning ............................................................................................................................... 170 Disinfestation .................................................................................................................................. 170 Waste Chutes - Repairs .................................................................................................................... 171

GLAZING ................................................................................................................. 172 Reglaze Doors and Windows ................................................................................................................ 172

Glass - Clear and Obscured ............................................................................................................... 172 Glass - Georgian Wired Cast ............................................................................................................. 172 Glass - Georgian Wired Polished ........................................................................................................ 172 Glass - Toughened ........................................................................................................................... 173 Glass - Laminated ............................................................................................................................ 173 Glass - Polycarbonate ....................................................................................................................... 173 Double Glazed Units - Clear Float Low Emissivity (Low E) Glass ........................................................... 174 Double Glazed Units - Safety Low Emissivity (Low E) Glass ................................................................. 174 Double Glazing Repairs..................................................................................................................... 174 Domelights ...................................................................................................................................... 174 Mirrors ............................................................................................................................................ 175 Shower Screens ............................................................................................................................... 175 Sundries .......................................................................................................................................... 175 Curtains .......................................................................................................................................... 177

PLUMBING ............................................................................................................... 178 Rainwater Pipework ............................................................................................................................. 178

Rainwater Pipework - PVCu .............................................................................................................. 178 Rainwater Pipework - Cast Iron Repairs ............................................................................................. 179

Rainwater Gutters ............................................................................................................................... 179 Rainwater Gutters - PVCu ................................................................................................................. 179 Rainwater Gutters - Cast Iron ........................................................................................................... 180 Gutters/Downpipes - Clean Out ......................................................................................................... 181

Foul Drainage Above Ground ................................................................................................................ 182 Soil and Vent Stacks - External - PVCu ............................................................................................... 182 Soil and Vent Stacks - Internal - PVCu ............................................................................................... 184 Soil and Vent Stacks - Cast Iron - Repairs .......................................................................................... 186

Waste Pipework and Fittings ................................................................................................................ 186 Waste Pipework and Fittings - Plastic ................................................................................................ 186

Page 30: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

7 Local Space Housing

Waste Pipework and Fittings - Copper ............................................................................................... 187 Soil/Waste Pipe Blockages ................................................................................................................ 188

Fittings, Equipment and Appliances Associated with Services .................................................................. 188 Sinks ............................................................................................................................................... 188 Sinks - Deep Bowl ............................................................................................................................ 190 Sink Tops - Inset ............................................................................................................................. 190 Sink Tops - Deep Bowl Inset ............................................................................................................. 191 Sink Base Units ................................................................................................................................ 191 WC Suites ....................................................................................................................................... 192 Wash Hand Basins ........................................................................................................................... 194 Baths .............................................................................................................................................. 196 Shower Trays .................................................................................................................................. 197 Shower Mixing Valves, Hoses and Heads ........................................................................................... 197 Shower Rails and Curtains ................................................................................................................ 198 Taps - Traditional Type .................................................................................................................... 199 Taps - Ceramic Disc Type ................................................................................................................. 199 Taps – Convert to Lever ................................................................................................................... 200 Taps - Mixers ................................................................................................................................... 200 Sealant Joints to Sanitary Appliances and Fittings ............................................................................... 201 Upstands ......................................................................................................................................... 201 Washing Machine Plumbing .............................................................................................................. 201

Supply Pipework .................................................................................................................................. 202 Copper Pipework - Renewals ............................................................................................................ 202 Copper Pipework - Extensions ........................................................................................................... 202 Burst Pipe Repairs ............................................................................................................................ 202

Pipe Insulation .................................................................................................................................... 203 Moulded Foam Pipe Insulation .......................................................................................................... 203

Stopcocks and Valves .......................................................................................................................... 203 Stopcocks ........................................................................................................................................ 203 Gatevalves ...................................................................................................................................... 204 Check and Service Valves ................................................................................................................. 204 Ballofix Valves ................................................................................................................................. 205 Draincocks ...................................................................................................................................... 205

Water Storage Tanks ........................................................................................................................... 205 Tanks - Cold Water Storage .............................................................................................................. 205 Tanks - Feed and Expansion ............................................................................................................. 205 Tanks - Repairs and Overhauls.......................................................................................................... 206 Insulation – Tank ............................................................................................................................. 206

Hot Water Cylinders ............................................................................................................................ 207 Cylinders - Pre-Insulated Direct ......................................................................................................... 207 Cylinders - Insulating Jacket Direct .................................................................................................... 207 Cylinders - Pre-Insulated Indirect ...................................................................................................... 207 Cylinders - Jacket Indirect ................................................................................................................ 208 Cylinders - Jacket Primatic ................................................................................................................ 208 Cylinders - Pre-Insulated Fortic Direct ............................................................................................... 208 Cylinders - PreInsulated Fortic Indirect .............................................................................................. 209 Cylinders - Economy 7 Type ............................................................................................................. 209 Cylinders - Elson Type Combination Tanks ......................................................................................... 209 Cylinders - Repairs etc...................................................................................................................... 210 Proprietary Prefabricated Hot/Cold Plumbing Units ............................................................................. 211 Scale Reducers ................................................................................................................................ 212

Sundry Works ..................................................................................................................................... 213 Airlocks ........................................................................................................................................... 213 Safety Checks and Drain Downs ........................................................................................................ 213 Duct Covers and Frames .................................................................................................................. 213 Bathroom Ancillaries ........................................................................................................................ 213 Fire Fighting Equipment ................................................................................................................... 214

Underground Water Mains ................................................................................................................... 215 Water Mains - Alkathene Pipework .................................................................................................... 215 Burst Water Mains - Copper Pipework ................................................................................................ 215 Burst Water Mains - Alkathene Pipework ............................................................................................ 215 External Stopcocks ........................................................................................................................... 215

Page 31: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

8 Local Space Housing

Client Inspections - Plumbing ............................................................................................................... 216 HEATING, GAS APPLIANCES AND INSTALLATIONS .................................................... 217

Heating .................................................................................................................................................. 217 Pumps and Valves ............................................................................................................................... 217

Pumps ............................................................................................................................................ 217 Motorised and Zone Valves Renewals ................................................................................................ 217

Radiators ............................................................................................................................................ 218 Radiators - Repairs .......................................................................................................................... 218 Radiator - Single Panel Renewals ...................................................................................................... 219 Radiators - Single Convector Renewal................................................................................................ 219 Radiators - Double Convector Renewals ............................................................................................. 220 Relocate Radiators ........................................................................................................................... 220 Heated Towel Rail ............................................................................................................................ 221 Radiator - Valves ............................................................................................................................. 221 Airlocks/Reprime .............................................................................................................................. 221 Power Flushing ................................................................................................................................ 221

Solid Fuel Appliances, Flue Linings and Pipes ......................................................................................... 222 Solid Fuel Backboilers ....................................................................................................................... 222 Multi-Fuel Roomheater with Boiler ..................................................................................................... 222 Roomheater with Boiler .................................................................................................................... 223 Flue Lining and Pipes ....................................................................................................................... 223

Heating Boilers Controls ....................................................................................................................... 224 Boiler Controls ................................................................................................................................. 224

Gas Point, Water and Space Heating Appliances .................................................................................... 225 Gas Fires ......................................................................................................................................... 225 Gas Water Heaters ........................................................................................................................... 225

Gas Boilers to Sedbuk ’A’ Rating ........................................................................................................... 226 Additional Builders Work ................................................................................................................... 226 Gas Boilers in Original Position .......................................................................................................... 226 Gas Boilers in New Position ............................................................................................................... 227

Domestic Gas Cookers ......................................................................................................................... 228 Domestic Gas Cooker - Fault Locating ............................................................................................... 228 Domestic Gas Cooker - Renewals ...................................................................................................... 228 Domestic Gas Cookers - Supply Hoses ............................................................................................... 229 Domestic Gas Cookers - Void Works .................................................................................................. 229

Void Works ......................................................................................................................................... 230 Void Property Works ........................................................................................................................ 230 Draining Down ................................................................................................................................. 231

ELECTRICAL ............................................................................................................ 232 Space Point and Water Heating Appliances ............................................................................................ 232

Storage Heaters ............................................................................................................................... 232 Combination Storage/Convector Heaters ............................................................................................ 232 Storage Heaters - Repairs ................................................................................................................. 233 Radiant and Convector Heaters ......................................................................................................... 233 Radiant and Convector Heaters - Repairs ........................................................................................... 235 Electric Towel Rail ............................................................................................................................ 235 Immersion Heaters .......................................................................................................................... 236 Water Storage Heaters ..................................................................................................................... 237 Water Storage Heaters - Repairs ....................................................................................................... 238 Electric Heating Controls .................................................................................................................. 238

Electrical Appliances ............................................................................................................................ 238 Showers - Electric ............................................................................................................................ 238 Domestic Type Cookers .................................................................................................................... 239 Domestic Type Cookers - Fault Locating ............................................................................................ 239 Domestic Type Cookers - Fault Locating/Repair .................................................................................. 239 Domestic Type Electric Cookers - Renewals ....................................................................................... 239 Cooker Control Units and Circuits ...................................................................................................... 240 Cooker Ventilation Hoods ................................................................................................................. 241 Domestic Type Electric Laundry Equipment ........................................................................................ 241 Domestic Type Electric Refrigerator ................................................................................................... 241 Domestic Type Electric Deep Freeze .................................................................................................. 242

Page 32: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

9 Local Space Housing

Domestic Type Electrical Equipment - Annual Testing ......................................................................... 243 Domestic Type Electrical Equipment - Response Call-Outs ................................................................... 243 Domestic Appliances Generally .......................................................................................................... 243 Waste Disposal Unit ......................................................................................................................... 243

Ventilation .......................................................................................................................................... 244 Fans - Ventilating ............................................................................................................................. 244 Fans - Condensation Control ............................................................................................................. 245 Low Energy Positive Output, Whole House Ventilation ........................................................................ 246

General Lighting and Power (Small Scale) ............................................................................................. 247 Conduit - PVC .................................................................................................................................. 247 Conduit - Galvanised Steel ................................................................................................................ 247 Cable - Drawn In Conduits ................................................................................................................ 247 Cable - Clipped to Backgrounds ......................................................................................................... 248 Cable and Conduit Chased into Background ....................................................................................... 248 Cable and Mini-Trunking ................................................................................................................... 249 Cables - MICC and MICV .................................................................................................................. 249

Final Circuits ....................................................................................................................................... 249 Final Circuits - Lighting ..................................................................................................................... 249 Final Circuits - Power ....................................................................................................................... 250 Consumer Control Units .................................................................................................................... 252

Pendants ............................................................................................................................................ 253 Pendants and Lampholders ............................................................................................................... 253

Luminaires - Bulkheads ........................................................................................................................ 254 Bulkhead - Fittings ........................................................................................................................... 254 Bulkhead - Lamps ............................................................................................................................ 254 Bulkhead - Diffuser .......................................................................................................................... 255

Luminaires - Fluorescent Lights ............................................................................................................ 255 Fluorescent - Fittings ........................................................................................................................ 255 Fluorescent - Diffusers ..................................................................................................................... 256 Fluorescent - Tubes ......................................................................................................................... 256 Low Energy Lamps ........................................................................................................................... 256

Accessories ......................................................................................................................................... 256 Accessories - Generally ..................................................................................................................... 256 Accessories - Light Switches ............................................................................................................. 257 Accessories - Socket Outlets ............................................................................................................. 258 Accessories - DP Switches ................................................................................................................ 259 Shaver Points .................................................................................................................................. 259

Special Installations ............................................................................................................................. 260 Door Bell Installation ........................................................................................................................ 260 Door Entry Installation ..................................................................................................................... 260 Fire Alarm Installations ..................................................................................................................... 261 Burglar Alarm Installation ................................................................................................................. 262 TV Aerial Installation ........................................................................................................................ 262 CCTV Service ................................................................................................................................... 263 Smoke Detectors ............................................................................................................................. 263 Heat Detectors ................................................................................................................................ 264 Carbon Monoxide Detectors .............................................................................................................. 264 Gas Detectors .................................................................................................................................. 265

Landlords Lighting etc. ........................................................................................................................ 265 Time Switches ................................................................................................................................. 265 Emergency Lighting Fittings .............................................................................................................. 266 Inspections...................................................................................................................................... 267

Overnight Temporary Connections ........................................................................................................ 267 Temporary Connections .................................................................................................................... 267 Temporary Equipment Hire ............................................................................................................... 267

Earthing ............................................................................................................................................. 268 Earthing - Plumbing Installations ....................................................................................................... 268 Earthing - Central Heating Equipment ................................................................................................ 268

Testing ............................................................................................................................................... 269 Testing - Occupied Property.............................................................................................................. 269 Portable Appliance Electrical Equipment - Annual Testing .................................................................... 269 Testing - Unoccupied Property .......................................................................................................... 270

Page 33: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

10 Local Space Housing

Water Penetration ............................................................................................................................ 270 Client Inspections - Electrical ............................................................................................................ 270

DISABLED ADAPTATIONS AND MINOR WORKS ......................................................... 271 Stairlifts .............................................................................................................................................. 271

Stairlifts - Ancillary Works ................................................................................................................. 271 Electrical Works ................................................................................................................................... 271

Consumer Unit ................................................................................................................................. 271 Socket Outlets ................................................................................................................................. 271 Switch Plate .................................................................................................................................... 271 Thermostat ..................................................................................................................................... 272

Communication Systems ...................................................................................................................... 272 Door Entry ...................................................................................................................................... 272 Smoke Detector ............................................................................................................................... 272

Grab Rails, Handrails and Balustrades ................................................................................................... 272 Grabrails - Proprietary - Stainless Steel, Polyester Coated, or Reinforced Plastic as Specified ................. 272 Handrails ......................................................................................................................................... 275 Balustrading .................................................................................................................................... 276

Plumbing Works .................................................................................................................................. 276 Sanitary Fittings ............................................................................................................................... 276 Taps ............................................................................................................................................... 277

Showers/Bath Aids .............................................................................................................................. 277 Shower Seat .................................................................................................................................... 277 Soap Dish ........................................................................................................................................ 278 Electric Showers .............................................................................................................................. 278 Shower Rooms ................................................................................................................................ 278 Shower Rails and Curtains ................................................................................................................ 279

Kitchen Units ...................................................................................................................................... 279 Kitchen Units - Adjustable Specification for Special Needs ................................................................... 279

Windows ............................................................................................................................................ 280 Window Adaptations and Ironmongery .............................................................................................. 280

Doors ................................................................................................................................................. 281 Door Adaptations and Ironmongery ................................................................................................... 281

Access Facilities................................................................................................................................... 281 Ramps ............................................................................................................................................ 281 Steps .............................................................................................................................................. 282 Thresholds ...................................................................................................................................... 282

SPECIALIST TREATMENTS ........................................................................................ 283 Fungus and Beetle Eradication and DPC Works ...................................................................................... 283

Reduce Existing Ground Level in Conjunction with DPC Wall Injection .................................................. 283 Works to Sub-Floors due to Fungus and Beetle Eradication or DPC Works ............................................ 283 Chemical DPC Wall Injection ............................................................................................................. 284 Irrigation of Walls ............................................................................................................................ 284 Floor Renewals due to Fungus/Beetle Eradication or DPC Works .......................................................... 285 Wall or Partition Renewals due to Fungus/Beetle Eradication or DPC Works ......................................... 285 Kitchen Units and Cupboard Works due to Fungus/Beetle Eradication or DPC Works ............................. 285 Damp Proof Treatment Plasterwork ................................................................................................... 286 Plumbing Works due to Fungus/Beetle Eradication or DPC Works ........................................................ 286

Timber Treatment ............................................................................................................................... 286 Flooring Treatment .......................................................................................................................... 286 Roof Treatment ............................................................................................................................... 287 Deep Paste Treatment...................................................................................................................... 288

Artex Removal .................................................................................................................................... 288 Removal of Artex Finishes ................................................................................................................ 288

Specialist Treatments .......................................................................................................................... 288 Graffiti Removal - External Surfaces .................................................................................................. 288 Bituminous Emulsion Damp Proofing Solution – External Walls ............................................................ 288 Anti-Vandal Paint – External Pipework ............................................................................................... 289 Anti-Vandal Paint – External Walls ..................................................................................................... 289

Mastic Asphalt Tanking etc ................................................................................................................... 289 Mastic Asphalt Tanking Damp Proof Membrane .................................................................................. 289 Mastic Asphalt Flooring ..................................................................................................................... 289

Page 34: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES

11 Local Space Housing

Mould Eradication ................................................................................................................................ 290 Mould Treatment ............................................................................................................................. 290

Pest Control ........................................................................................................................................ 291 Pest Control .................................................................................................................................... 291

Page 35: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

1 Local Space Housing

FOUNDATIONS Floor - Concrete Internal Renewal 015003 R FLOOR:RENEW INTERNAL CONCRETE INSULATION SM 146.91 Floor:Renew complete any floor with new concrete floor including

break up existing floor, applied finish and sub-base under and remove waste and debris, excavate as necessary, compact bottoms and lay and compact ne 175mm hardcore bed blinded with sand, lay 1200 gauge polythene damp proof membrane, 50mm Jablite or other equal and approved insulation board, both membrane and board turned up 150mm at edges, 150mm concrete slab (1:2:4) with mesh reinforcement and ne 65mm cement and sand floor screed trowelled smooth to receive floor finish, remove and refix skirtings as necessary and make good all finishes.

Floor - Concrete Internal New 015007 R FLOOR:NEW INTERNAL CONCRETE WITH INSULATION SM 134.67 Floor:Excavate as necessary, remove waste and debris, compact

bottoms and lay and compact ne 175mm hardcore bed blinded with sand, lay 1200 gauge polythene damp proof membrane, 50mm Jablite or other equal and approved insulation board, both membrane and board turned up 150mm at edges, 150mm concrete slab (1:2:4) with mesh reinforcement and ne 65mm cement and sand floor screed trowelled smooth to receive floor finish, remove and refix skirtings as necessary and make good all finishes.

Foundations in Trenches 049001 R FOUNDATIONS:EXCAVATE CONCRETE TRENCH LM 279.46 Foundations:Excavate trench 600mm wide and ne 1.00m deep

including all necessary planking and strutting, return, fill in and ram, remove waste and debris, level and ram, lay concrete (1:3:6) in trench to depth ne 775mm build cavity wall in engineering bricks and facings in cement mortar (1:3) including damp proof course, build in stainless steel wall ties, fill cavity of wall with concrete (1:10), including all labours.

Page 36: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

2 Local Space Housing

GROUNDWORKS Kerbs, Channels and Edgings Kerbs - Precast Concrete 001101 R KERB:LAY NEW 127X254MM PCC KERB LM 34.53 Kerb:Excavate, remove waste and debris, subsequently backfill as

necessary, level and compact bottom of excavations, supply and lay 127x254mm precast concrete kerb, straight or curved, on and including 200x100mm concrete bed and haunch both sides and pointing, all necessary formwork and make good to existing finishes.

001103 R KERB:RENEW 127X254MM PCC KERB LM 26.02 Kerb:Renew precast concrete kerb, straight or curved by carefully

taking up existing kerb and haunching, remove waste and debris, clean up concrete bed, supply and lay new 127x254mm precast concrete kerb and haunch to both sides including pointing, formwork and make good to existing finishes.

001105 R KERB:REBED ANY TYPE OF PCC KERB LM 21.27 Kerb:Rebed precast concrete kerb, straight or curved on plan, by

carefully taking up existing kerb and haunching, remove waste and debris, clean up concrete bed and bed and haunch to existing 127x254mm precast concrete kerb to both sides including pointing, formwork and make good to existing finishes.

Channels - Precast Concrete 001301 R CHANNEL:RENEW NE 250X125MM LM 25.88 Channel:Renew precast concrete channel, take up existing including

haunching, remove waste and debris, clean up existing bed, supply and lay new ne 250x125mm precast concrete channel including haunch both sides, pointing, formwork and make good to existing finishes

001303 R CHANNEL:REBED NE 250X125MM LM 21.27 Channel:Rebed precast concrete channel, take up existing including

haunching, remove waste and debris, clean up existing bed, and clean and relay ne 250x125mm precast concrete channel including haunch both sides, pointing, formwork and make good to existing finishes.

Edgings - Precast Concrete 001501 R EDGING:LAY 50X152MM PCC EDGING LM 26.19 Edging:Excavate, remove waste and debris, backfill as necessary,

level and compact bottom of excavations lay concrete bed 200x100mm and supply and lay 50x152mm precast concrete edging, straight or curved, haunch to both sides, point including all formwork and make good to existing finishes.

001503 R EDGING:RENEW 50X152MM PCC EDGING LM 19.11 Edging:Renew precast concrete edging, straight or curved by

carefully taking up existing edging and haunching, remove waste and debris, clean up concrete bed, supply and bed ne 50x152mm precast concrete edging, haunch both sides, point including all formwork and make good to existing finishes.

Page 37: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

3 Local Space Housing

001505 R EDGING:REBED STRAIGHT AND CURVED PCC EDGING LM 16.51 Edging:Rebed any precast concrete edging, straight or curved on

plan, by carefully taking up existing edging and haunching, remove waste and debris, clean up concrete bed and edging and relay including haunch both sides, point including all formwork and make good to existing finishes.

Edgings - Timber 001507 R EDGING:RENEW 25X150MM TIMBER LM 7.76 Edging:Renew or supply and fix new 25x150mm tanalised softwood

edging board to and including 50x50x600mm long tanalised pegs at 900mm centres driven firmly into the ground including all necessary excavation and make good to existing finishes.

Paths and Pavings Paving - Insitu Concrete 003003 R PATH:EXCAVATE LAY NE 100MM CONCRETE BED SM 71.32 Path:Excavate 250mm below required finished level, remove waste

and debris, level and compact bottoms of excavations and fill, 150mm hardcore bed, blinded and ne 100mm concrete trowelled smooth including dishing to gullies and the like and all formwork.

003007 R PATH:RENEW NE 100MM CONCRETE BED AND SUB-BASE SM 82.26 Path:Renew concrete path by breaking up existing concrete and

excavating 250mm below existing level, remove waste and debris, fill soft spots, level and compact bottoms of excavations and fill, 150mm hardcore bed, blinded and ne 100mm concrete trowelled smooth including dishing to gullies and the like and all formwork.

003009 R FINISH:EXTRA FOR NON-SLIP FINISH TO PATH SM 3.97 Finish:Extra for non-slip surface to concrete carborundum grains at

the rate of 1kg per sm.

003011 R PATH:REMOVE AND INFILL WITH TOPSOIL SM 51.69 Path:Break up and remove any thickness existing path and bed

under and remove waste and debris, import topsoil and deposit to make up levels and grade to suit existing contours.

Paving - Coated Macadam 005001 R MACADAM:EXCAVATE AND LAY 70MM PAVING SM 49.45 Macadam:Excavate 145mm below required finished level, remove

waste and debris, level and compact bottoms of excavations and fill in layers, 75mm crusher run of broken stone blinding, 50mm base course of 20mm nominal size open-textured macadam and 20mm wearing course of 6mm nominal medium textured macadam laid to falls, crossfalls and slopes.

005003 R MACADAM:RENEW 70MM PAVING SM 53.82 Macadam:Renew macadam by breaking up existing paving and

excavations 145mm below existing level, remove waste and debris, fill soft spots, level and compact bottoms of excavations and fill in layers, 75mm crusher run of broken stone, blinding, 50mm base course of 20mm nominal size open textured macadam and 20mm wearing course of 6mm nominal size medium textured macadam laid to falls, crossfalls and slopes, make good to existing finishes.

Page 38: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

4 Local Space Housing

Paving - Precast Concrete Flag 007001 R FLAG:EXCAVATE AND LAY NEW PRECAST CONCRETE SM 55.95 Flag:Excavate 150mm below required finished level, remove waste

and debris, and fill in layers, including compacting 75mm crusher run of broken stone blinding and lay 50mm standard size precast concrete paving flags on 25mm bed of cement mortar (1:4) including point up joints and all cutting and dishing to gullies, covers and the like.

007005 R FLAG:LIFT AND REBED SINGLE PCC PAVING NO 8.56 Flag:Lift any size existing precast concrete paving flag, fill and

compact hardcore to soft spots and rebed existing flag on 25mm bed of cement mortar (1:4) and point up joints.

007007 R FLAGS:LIFT AND REBED PCC PAVING SM 23.26 Flag:Lift any size existing precast concrete paving flag, fill and

compact hardcore to soft spots and rebed existing flags on 25mm bed of cement mortar (1:4) and point up joints.

007009 R FLAG:RENEW SINGLE PCC PAVING NO 12.54 Flag:Lift remnants of existing 50mm standard size precast concrete

paving flag, remove waste and debris, fill and compact hardcore to soft spots and lay new flag on 25mm bed of cement mortar (1:4), point up joints including any additional cutting and fitting to suit.

007011 R FLAGS:RENEW PCC PAVING SM 36.50 Flag:Lift remnants of existing 50mm standard size precast concrete

paving flag, , remove waste and debris, fill and compact hardcore to soft spots and lay new paving on 25mm bed of cement mortar (1:4), point up joints including any additional cutting and fitting to suit.

007019 R FLAG:REPOINT PCC PAVING SM 10.56 Flag:Repoint pcc paving, rake out joints, repoint with cement

mortar (1:4).

007021 R FLAG:FILLET POINT JOINT TO WALL LM 2.33 Flag:Rake out existing and or fillet point in cement mortar (1:4),

joint between edges of paving and wall and abutment.

Paving - Brick 009001 R PAVING:REBED BRICK PAVING-MORTAR OR SAND SM 79.11 Paving:Take up loose brick paving, set aside, clean bed and bricks,

and relay brick paving including jointing and pointing in cement mortar (1:4) or joint filling sand including all bonding.

009005 R PAVING:RENEW BRICK PAVING-MORTAR OR SAND SM 87.16 Paving:Renew brick paving including take up existing, remove

suplus spoil, fill and compact hardcore to soft spots and lay new paving on 25mm bed of cement mortar (1:4) or 50mm sand bed including all pointing and cutting and bonding.

009009 R PAVING:LAY NEW BRICK PAVING-MORTAR OR SAND SM 103.11 Paving:Supply and lay new brick paving including excavate to level,

lay 100mm hardcore bed and lay new paving on 25mm bed of cement mortar (1:4) or 50mm sand bed including all pointing and cutting and bonding.

Page 39: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

5 Local Space Housing

Paving - Gravel 009013 R PAVING:RENEW GRAVEL PAVING 30MM SM 7.01 Paving:Renew gravel paving to paths and driveways ne 30mm thick

including take up and clear away existing, remove waste and debris, supply, spread and level washed gravel to existing surfaces.

Paving - Temporary Repairs 011001 R PAVING:TEMPORARY CONCRETE REPAIR IT 33.07 Paving:Break out existing defective paving of any type if necessary

ne 100mm thick and clear away, remove waste and debris, fill in void with lean mix concrete ensuring flush edges to existing finishes in areas ne 1.00sm.

Hardcore 011101 R HARDCORE:ADDITIONAL SUB-BASE OR BED NE 150 SM 30.53 Hardcore:Extra for additional hardcore sub-base or bed ne 150mm

thick laid under any type of paving including excavate, remove spoil, level and compact bottoms, remove waste and debris, (to be charged only when specifically ordered by Client Representative).

Steps, Stairs and Ramps Steps, Stairs and Ramps - Insitu and Precast Concrete 013001 R STEP:FORM OR RENEW STEP IN CONCRETE PAVING IT 38.93 Step:Form step ne 1000x300x200mm in concrete paving including

all necessary excavation, hardcore, extra concrete and all formwork with surfaces trowelled smooth, make good to adjacent finishes and remove waste and debris.

013005 R STEP:FORM OR RENEW PCC STEP IN PAVING IT 45.60 Step:Form step in precast concrete paving ne 1000x300x200mm

including all extra excavation, hardcore, blinding and bed precast concrete flags to steps and risers on 25mm mortar bed including all cutting, make good to adjacent finishes and remove waste and debris.

013009 R STEP:FORM BRICK ON EDGE STEP LM 20.24 Step:Form step with approved brick on edge, bedded and pointed

in cement mortar (1:4).

013011 R STEP:REPAIR DAMAGED CONCRETE IT 19.68 Step:Cut out damaged section and repair step as necessary with

concrete (1:1:5:3) or cement and sand polymer enhanced cementitious mortar including formwork and trowel finish.

013013 R STEP:REFIX AND BED LOOSE STEP IT 7.42 Step:Rebed loose precast concrete step or loose bricks to brick step

including remove existing, clean off as necessary and rebed in cement mortar (1:4) (per step).

013015 R RAMP:CONSTRUCT CONCRETE RAMP LM 100.82 Ramp:Construct insitu concrete ramp average 150mm thick, ne

1.5m wide overall with 50mm high insitu concrete kerbs to both sides, laid to any gradient specified ne 1:15 with pinked finish including all excavation, remove waste and debris, hardcore, reinforcement and formwork.

Page 40: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

6 Local Space Housing

Metal Stairs and Walkways and Balustrades Balustrades - Isolated 027101 U BALUSTRADE:TAKE DOWN AND REMOVE LM 7.88 Balustrade:Take down existing balustrade, remove waste and

debris, and prepare mortices to receive new balustrade.

027103 U BALUSTRADE:SUPPLY AND FIX-1.2M HIGH LM 195.57 Balustrade:Supply and fix galvanised mild steel balustrade 1200mm

high comprising 6x50mm horizontal rails, 25x25mm standards, ragged at end at 2.00m centres and 12x12mm balusters all welded together and set in mortices in mortar, rub down and prepare for and decorate to all surfaces.

027105 U BALUSTRADE:SUPPLY AND FIX KEE KLAMP LM 70.65 Balustrade:Supply and fix galvanised mild steel tubular kee-klamp

balustrade, 900mm high comprising 48mm diameter horizontal rails, 48mm diameter standards at 1.00m centres and set in mortices in mortar, rub down, and prepare for and decorate to all surfaces.

Handrails - Associated 027303 U HANDRAIL:6X50MM RAIL ON BRACKETS LM 36.36 Handrail:Supply and fix 6x50mm galvanised mild steel rail welded

to and including handrail brackets, plugged and screwed to brickwork, rub down, prepare for and decorate to all surfaces.

027305 U HANDRAIL:48MM GALVANISED STEEL TUBULAR ON BRACKETS LM 37.60 Handrail:Supply and fix 48mm diameter galvanised mild steel

tubular handrail welded to and including handrail brackets, plugged and screwed to brickwork, rub down, prepare for and decorate to all surfaces.

027307 U HANDRAIL:PVC TO CORE RAIL LM 15.61 Handrail:Supply and fix PVC handrail to core rail including all ends,

bends and ramps etc.

027309 U HANDRAIL:RENEW MOPSTICK HANDRAIL LM 10.19 Handrail:Renew or supply and fix new softwood mopstick handrail

to existing brackets including all ends and refix handrail brackets including replugging if necessary, redecorate and make good finishes.

Balustrades and Handrails - Sundry Repairs 027501 U BALUSTRADE:REFIX ANY LOOSE TYPE LM 17.87 Balustrade:Refix any type of loose balustrade including remove if

necessary, clean out and prepare mortices including reforming if required to ensure sound fixings and refix balustrade and make good decorations and finishes.

027503 U HANDRAIL:REFIX ANY LOOSE TYPE LM 13.31 Handrail:Refix any type of loose handrail including remove if

necessary, clean out and prepare mortices including reforming if required and or replug to ensure sound fixings and refix handrail, make good decorations and finishes.

Page 41: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

7 Local Space Housing

Miscellaneous Fittings Clothes Lines 029101 U LINE:NEW DOMESTIC ROTARY AND BASE NO 102.89 Line:Erect domestic rotary clothes line with loose socket, excavate

for and including concrete base and remove waste and debris, and reinstate paving or garden areas.

029103 U LINE:NEW COMMUNAL/HEAVY DUTY ROTARY AND BASE NO 197.89 Line:Erect communal or heavy duty rotary clothes line with loose

socket, excavate for and including concrete base, remove waste and debris, and reinstate paving or garden areas.

029105 U LINE:RENEW DOMESTIC ROTARY NO 73.41 Line:Renew domestic rotary clothes line, set in existing socket and

clear away, remove waste and debris.

029107 U LINE:RENEW COMMUNAL/HEAVY DUTY ROTARY NO 168.42 Line:Renew communal or heavy duty rotary clothes line, set in

existing socket and clear away, remove waste and debris.

029109 U LINE:RE-STRING CLOTHES LINE NO 22.42 Line:Re-string any clothes line including remove remains of existing

line.

029111 R LINE:NEW PCC CLOTHES POST AND BASE NO 57.10 Line:Erect 150x150x2700mm precast concrete clothes post,

excavate for and including concrete base, remove waste and debris and reinstate paving or garden areas.

029115 R LINE:NEW STEEL CLOTHES POST-NE 3.0M NO 69.26 Line:Erect 50mm diameter galvanised steel clothes post upto 3.00m

long with pulleys, excavate for and including concrete base, and remove waste and debris and reinstate paving or garden areas.

029117 R LINE:RELOCATE ROTARY DRIER NO 42.16 Line:Relocate rotary clothes drier in new position, carefully break

out or renew aluminium tube socket, remove existing concrete base, excavate for and including new concrete base remove waste and debris and reinstate paving or garden areas.

029119 R LINE:RELOCATE PCC OR STEEL CLOTHES POST NO 38.23 Line:Relocate precast concrete or steel clothes post in new position,

carefully break out existing post, remove existing concrete base, excavate for and including new concrete base and remove waste and debris and reinstate paving or garden areas.

029123 R LINE:RENEW PULLEY IT 18.71 Line:Renew pulley wheel and bracket to clothes line, including

fixing to any background.

029125 R LINE:RENEW RESTRAINING BRACKET IT 11.74 Line:Renew restraining bracket to clothes Line including fixing to

any background.

Page 42: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

8 Local Space Housing

Signs 029301 R SIGN:COLLECT AND FIX NO 13.85 Sign:Collect sign from Client’s Office and screw to timber, plug and

screw to masonry or bolt to metal posts.

029303 R SIGN:NEW NO PARKING NO 60.79 Sign:Supply standard 'No Parking' sign and screw to timber, plug or

screw to masonry or bolt to metal posts.

029305 R SIGN:NEW NO BALL GAMES NO 60.79 Sign:Supply standard 'No Ball Games' sign and screw to timber,

plug or screw to masonry or bolt to metal posts.

029307 R SIGN:NEW NO DOGS NO 60.79 Sign:Supply standard 'No Dogs' sign and screw to timber, plug or

screw to masonry or bolt to metal posts.

Bollards 031001 U BOLLARD:RENEW OR FIX NEW LOCKABLE STEEL NO 184.99 Bollard:Renew with or supply and fix new proprietary lockable steel

bollard including remove old, position and set foundation bolts in concrete or brick paving, fix new bollard and make good all finishes disturbed, and remove waste and debris and reinstate paving or garden areas, supply two keys and hand to Client Representative.

031005 U BOLLARD:RENEW OR FIX NEW 914MM HIGH STEEL NO 125.11 Bollard:Renew with or supply and fix new 76mm diameter x 914mm

high above ground steel fixed bollard bedded in concrete including remove old, excavate as necessary, fix new bollard including concrete foundation and make good all finishes disturbed and remove waste and debris and reinstate paving or garden areas.

031009 U BOLLARD:RENEW OR FIX NEW PCC 900MM HIGH NO 97.04 Bollard:Renew with or supply and fix new 225 to 150mm diameter

tapered precast concrete bollard 900mm high above ground bedded in concrete including remove existing, excavate as necessary, fix new bollard including concrete foundation and make good all finishes disturbed and remove waste and debris and reinstate paving or garden areas.

031013 U BOLLARD:RENEW OR FIX NEW 800MM TIMBER NO 63.40 Bollard:Renew with or supply and fix new 150x150mm timber

bollard, 800mm high above ground including remove existing, excavate as necessary, fix new bollard including concrete foundation and make good all finishes and remove waste and debris and reinstate paving or garden areas.

Garden Sheds 070101 R SHED:INSTALL PROPRIETARY STORAGE INCLUDING SLAB IT 658.11 Shed:Supply and install proprietary storage shed (PC Sum for

supply and delvery to site £300.00 excluding VAT) approximate plan size 2400x1800mm complete with door, all ironmongery, locks etc., shed fixed to and including 150mm concrete slab laid on and including damp proof membrane on blinded hardcore bed, include for all excavation, remove waste and debris, compacting as necessary, and remove waste and debris.

Page 43: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

9 Local Space Housing

070102 R SHED:INSTALL PROPRIETARY STORAGE EXCLUDING SLAB IT 519.81 Shed:Supply and install proprietary storage shed (PC Sum for

supply and delivery to site £300.00 excluding VAT) approximate plan size 2400x1800mm complete with door, all ironmongery, locks etc., shed fixed to existing concrete or precast concrete hardstanding.

070105 R SHED DOOR:RENEW L AND B DOOR 177.21 Door:Renew shed or bin store door with any size 40mm thick single

softwood matchboard ledged and braced door with 169x20mm ledges and 106x20mm braces covered on face with 20mm tongued, grooved and v jointed boarding, including remove existing door and hinges, remove and refit door stop as necessary, fit and hang new door on one pair of tee hinges, make good frame, complete with all ironmongery and decorate to match existing, and remove waste and debris.

070107 R SHED DOOR:RENEW F L AND B DOOR NO 198.41 Door:Renew shed or bin store door with any size 40mm thick single

softwood matchboard framed, ledged and braced door with 169x20mm ledges and 106x20mm braces covered on face with 20mm tongued, grooved and v jointed boarding, including remove existing door and hinges, remove and refit door stop as necessary, fit and hang new door on one pair of tee hinges, make good frame, complete with all ironmongery and decorate to match existing, and remove waste and debris.

070109 R SHED LOCK:RENEW COMPLETE NO 72.04 Shed Lock:Renew rimlock, keep and set of rimlock furniture to shed

or bin store door, including altering door as necessary for new lock and housing out existing frame as necessary, and remove waste and debris.

070111 U SHED DOOR:RENEW OR FIX NEW PADLOCK NO 10.52 Shed Door:Renew or supply and fix 50mm galvanised approved

padlock to shed or bin store door, supply two keys and hand to Tenant or Client Representative.

070113 U SHED DOOR RENEW WITH HASP AND STAPLE NO 19.79 Shed Door:Renew any type of hasp and staple to shed or bin store

door.

070115 U SHED DOOR:RENEW HASP AND PADLOCK NO 24.63 Shed Door:Renew any type of hasp, staple and 50mm galvanised

approved padlock to shed or bin store door, supply two keys and hand to Tenant or Client Representative.

Coal Bunkers 080001 U COAL BUNKER:REMOVE EXISTING NO 45.13 Coak Bunker:Take down existing damaged coal bunker and remove waste

and debris.

080003 R COAL BUNKER:RENEW WOODEN TOP NO 57.06 Coal Bunker:Take off existing wooden top and remove waste and debris,

fix new wooden top.

080005 R COAL BUNKER:RENEW CONCRETE TOP NO 51.45 Coal Bunker:Take off existing concrete top and remove waste and debris,

fix new concrete top.

Page 44: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

10 Local Space Housing

080007 R COAL BUNKER:FIX NEW TO EXISTING BASE NO 201.11 Coal Bunker:Supply and fix new precast concrete sectional coal bunker, 12

cwt capacity complete to existing base.

080009 R COAL BUNKER:PREPARE BASE NO 63.65 Coal Bunker:Excavate to reduce levels, lay 100mm granular sub base well

compacted, lay 2 No. 900x600mm precast concrete paving slabs, solid bedded on cement mortar (1:3) ready to receive coal bunker, r remove waste and debris.

Page 45: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

11 Local Space Housing

FENCING AND GATES Fencing Fencing - Boarded 017110 R FENCING:RENEW 1.2M BOARD PCC POST GRAVEL BOARD LM 86.16 Fencing:Renew or provide new 1.05m tanalised timber vertical

board fencing including for taking down remnants of existing fence and posts set in concrete, remove waste and debris, and set 100x100mm x 1.65m long concrete posts in concrete at ne 1.80m centres with two 69x44mm softwood rails bolted to posts and 144x20mm vertical boards nailed to rails, precast concrete gravel board with centre prop (measured per metre run of fencing).

017111 R FENCING:RENEW 1.2M BOARD TIMBER POST LM 80.89 Fencing:Renew or provide new 1.05m tanalised timber vertical

board fencing including for taking down remnants of existing fence and posts set in concrete, remove waste and debris, and set 100x100mm x 1.65m long softwood posts in concrete at ne 1.80m centres with two 69x44mm softwood rails bolted to posts and 144x20mm vertical boards nailed to rails, softwood gravel board with centre prop (measured per metre run of fencing).

017113 R FENCING:RENEW 1.8M BOARD PCC POST LM 122.63 Fencing:Renew or provide new 1.65m high tanalised timber vertical

board fencing including for taking down remnants of existing fence and posts set in concrete, remove waste and debris, and set 125x125mm x 2.25m long concrete posts in concrete at ne 1.80m centres with three softwood rails 69x44mm bolted to posts and 144x20mm vertical boards nailed to rails 25x150mm softwood gravel board with centre prop (measured per metre run of fencing).

017114 R FENCING:RENEW 1.8M BOARD PCC POST GRAVEL BOARD LM 123.91 Fencing:Renew or provide new 1.65m high tanalised timber vertical

board fencing including for taking down remnants of existing fence and posts set in concrete, remove waste and debris, and set 125x125mm x 2.25m long concrete posts in concrete at ne 1.80m centres with three softwood rails 69x44mm bolted to posts and 144x20mm vertical boards nailed to rails precast concrete gravel board with centre prop (measured per metre run of fencing).

017117 R FENCING:RENEW SOFTWOOD RAIL NO 23.91 Fencing:Renew 69x44mm softwood rail ne 2.00m long bolted to

concrete or timber post by carefully removing vertical boards as necessary, renew rail, renail existing vertical boards, remove waste and debris.

017119 R FENCING:RENEW 2ND AND 3RD RAIL NO 7.71 Fencing:Renew second or third 69x44mm softwood rail ne 2.00m

long, whilst vertical boards removed, remove waste and debris.

017121 R FENCING:RENEW VERTICAL BOARD-1.05M NO 5.44 Fencing:Renew 144x20mm softwood vertical board 1.05m high,

remove waste and debris.

Page 46: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

12 Local Space Housing

017122 R FENCING:RENEW RUN OF VERTICAL BOARD-1.05M LM 53.40 Fencing:Renew 144x20mm softwood vertical boarding 1.05m high

to closeboarded fence high complete with fixing, wire clipped to boards, remove waste and debris, (measured per metre run of fencing).

017123 R FENCING:RENEW VERTICAL BOARD-1.675M NO 7.29 Fencing:Renew 144x20mm softwood vertical board 1.65m high,

remove waste and debris.

017124 R FENCING:RENEW RUN OF VERTICAL BOARD-1.675M LM 70.06 Fencing:Renew 144x20mm softwood vertical boarding 1.65m high

to closeboarded fence complete with fixing, wire clipped to boards, remove waste and debris (measured per metre run of fencing).

017125 R FENCING:REMOVE BOARD FENCE LM 9.27 Fencing:Take down and remove any height vertical board fence

consisting of concrete and or timber posts set in concrete, softwood rails, gravel board and vertical boards and remove waste and debris, fill post holes with top soil.

017127 R FENCING:RENEW TIMBER GRAVEL BOARD NO 15.53 Fencing:Renew or supply and fix new 25x150mm tanalised

softwood gravel board and centre prop including remove existing, excavate as necessary, cut and or trim existing fence boards as necessary and fix gravel board with galvanised nails, remove waste and debris.

017128 R FENCING:RENEW PCC GRAVEL BOARD NO 17.13 Fencing:Renew or supply and fix new ne 50x225mm precast

concrete gravel board and centre prop including remove existing, excavate as necessary, cut and or trim existing fence boards as necessary and fix gravel board with cleats and or bolts, remove waste and debris.

Fencing - Chestnut Pale 017201 R FENCING:RENEW CHESTNUT NE 1.5M AND POSTS LM 18.25 Fencing:Renew chestnut pale fencing ne 1.50m high including for

taking down remnants of existing fence and posts, remove waste and debris, and renew by driving in 60mm diameter sweet chestnut posts at 2.22m centres including galvanised accessories and sweet chestnut struts and chestnut pales at 75mm centres, fixed at head and bottom with galvanised straining wire (measured per metre run of fencing).

017205 R FENCING:RENEW CHESTNUT NE 1.5M LM 12.97 Fencing:Renew existing pales and wire on existing posts by

carefully removing, remove waste and debris, and renew with chestnut pales ne 1.50m high at 75mm centres fixed at head and bottom with galvanised straining wire (measured per metre run of fencing).

017209 R FENCING:REMOVE DAMAGED CHESTNUT LM 8.75 Fencing:Remove damaged chestnut pale fencing, remove waste

and debris (measured per metre run of fencing).

Page 47: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

13 Local Space Housing

017211 R FENCING:RENEW INDIVIDUAL CHESTNUT PALE NO 6.22 Fencing:Renew cleft chestnut pale to fence including remove

existing and remove waste and debris and fix new to match existing.

017213 R FENCING:LINE WIRE SUPPORT LM 2.85 Fencing:Renew or fix new galvanised or PVC coated line wire to

support cleft chestnut pale fence, fix wire to posts and fencing with galvanised staples and ties including remove and refix fencing as found expedient (measured per run of line wire).

017215 R FENCING:RENEW 75MM STRAIN POST NO 15.15 Fencing:Renew 75mm timber sweet chestnut straining post 1.60m

long to chestnut pale fencing including connecting bolt strainers, remove waste and debris.

Fencing - Interwoven and Overlap Fence Panels 017301 R FENCING:RENEW 1.8M HIGH PANEL NO 52.53 Fencing:Renew any interwoven or overlap fence panel ne

1.80x1.80m fixed with galvanised metal support brackets to existing posts, remove and dismantle existing and remove waste and debris.

017302 R FENCING:RENEW 1.2M HIGH PANEL NO 50.19 Fencing:Renew any interwoven or overlap fence panel ne

1.80x1.20m fixed with galvanised metal support brackets to existing posts, remove and dismantle existing and remove waste and debris.

017308 R FENCING:RENEW 1.2M WIDE PANEL NO 50.19 Fencing:Renew any interwoven or overlap fence panel ne

1.20x1.80m fixed with galvanised metal support brackets to existing posts, remove and dismantle existing and remove waste and debris.

017314 R FENCING:RENEW 0.9M HIGH PANEL NO 48.00 Fencing:Renew any interwoven or overlap fence panel ne

1.80x0.90m fixed with galvanised metal support brackets to existing posts, remove and dismantle existing and remove waste and debris.

017303 R FENCING:ERECT 1.8M HIGH PANEL WITH TIMBER POSTS LM 59.63 Fencing:Erect tanalised 1.80m high interwoven or overlap panel

fencing complete consisting of interwoven or overlap fencing panels fixed with galvanised metal support brackets to and including 75x75mm fence posts, posts set in concrete, capping, 25x150mm gravel board with centre prop, allow for all necessary excavation including excavation for posts, concrete, backfill and remove waste and debris, reinstate paving and gardens as necessary (measured per metre run of fencing).

017304 R FENCING:ERECT 1.2M HIGH PANEL WITH TIMBER POSTS LM 54.11 Fencing:Erect tanalised 1.20m high interwoven or overlap panel

fencing complete consisting of interwoven or overlap fencing panels fixed with galvanised metal support brackets to and including 75x75mm fence posts, posts set in concrete, capping, 25x150mm gravel board with with centre prop, allow for all necessary excavation including excavation for posts, concrete, backfill and remove waste and debris, reinstate paving and gardens as necessary (measured per metre run of fencing).

Page 48: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

14 Local Space Housing

017316 R FENCING:ERECT 0.9M HIGH PANEL WITH TIMBER POSTS LM 48.51 Fencing:Erect tanalised 0.90m high interwoven or overlap panel

fencing complete consisting of interwoven or overlap fencing panels fixed with galvanised metal support brackets to and including 75x75mm fence posts, posts set in concrete, capping, 25x150mm gravel board with centre prop, allow for all necessary excavation including excavation for posts, concrete, backfill and remove waste and debris, reinstate paving and gardens as necessary (measured per metre run of fencing).

017305 R FENCING:ERECT 1.8M HIGH PANEL WITH PCC POSTS LM 65.67 Fencing:Erect tanalised 1.80m high interwoven or overlap panel

fencing complete consisting of 1 interwoven or overlap fencing panels fixed with galvanised metal support brackets to and including 100x100mm pcc posts, posts set in concrete, capping 25x150mm precast concrete gravel board, allow for all necessary excavation including excavation for posts, concrete, backfill and remove waste and debris, reinstate paving and gardens as necessary (measured per metre run of fencing).

017306 R FENCING:ERECT 1.2M HIGH PANEL WITH PCC POSTS LM 59.48 Fencing:Erect tanalised 1.20m high interwoven or overlap panel

fencing complete consisting of 1 interwoven or overlap fencing panels fixed with galvanised metal support brackets to and including 100x100mm pcc posts, posts set in concrete, capping 25x150mm precast concrete gravel board, allow for all necessary excavation including excavation for posts, concrete, backfill and remove waste and debris, reinstate paving and gardens as necessary (measured per metre run of fencing).

017318 R FENCING:ERECT 0.9M HIGH PANEL WITH PCC POSTS LM 53.57 Fencing:Erect tanalised 0.90m high interwoven or overlap panel

fencing complete consisting of 1 interwoven or overlap fencing panels fixed with galvanised metal support brackets to and including 100x100mm pcc posts, posts set in concrete, capping 25x150mm precast concrete gravel board, allow for all necessary excavation including excavation for posts, concrete, backfill and remove waste and debris, reinstate paving and gardens as necessary (measured per metre run of fencing).

017307 R FENCING:REMOVE PANEL FENCE COMPLETE LM 7.96 Fencing:Remove any panel fencing complete including timber or

concrete posts, gravel boards etc and remove waste and debris, fill post holes with top soil and reinstate paths and gardens (measured per metre run of fencing).

Fencing - Chainlink 017401 R FENCING:ERECT CHAINLINK FENCE AND POSTS 1.2M LM 41.78 Fencing:Erect new chainlink fencing 1.20m high with 100x100mm x

1.625m concrete posts cast into concrete with three 2.5mm diameter galvanised mild steel line wires and galvanised or plastic coated steel chainlink fencing including all fittings, ties etc. and all excavation, concrete backfill and remove waste and debris, reinstatement of paving, gardens and the like (measured per metre run of fencing).

Page 49: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

15 Local Space Housing

017403 R FENCING:ERECT CHAINLINK FENCE AND POSTS 1.8M LM 47.39 Fencing:Erect new chainlink fencing 1.80m high with 100x100mm x

2.35m concrete posts cast into concrete with three 2.5mm diameter galvanised mild steel line wires and galvanised or plastic coated steel chainlink fencing including all fittings, ties etc. and all excavation, concrete backfill and remove waste and debris, reinstatement of paving, gardens and the like (measured per metre run of fencing).

017405 R FENCING:RENEW CHAINLINK ON EXISTING POSTS 1.2M LM 13.02 Fencing:Renew chainlink fencing 1.20m high on existing posts,

including removal of old and remove waste and debris, supply and fix new galvanised or plastic coated steel chainlink fencing including three 2.50mm diameter galvanised mild steel line wires and all fittings ties etc. (measured per metre run of fencing).

017407 R FENCING:RENEW CHAINLINK ON EXISTING POSTS 1.8M LM 15.12 Fencing:Renew chainlink fencing 1.80m high on existing posts,

including removal of old and remove waste and debris, supply and fix new galvanised or plastic coated steel chainlink wire fencing including three 2.50mm diameter galvanised mild steel line wires and all fittings, ties etc. (measured per metre run of fencing).

017409 R FENCING:REMOVE CHAINLINK COMPLETE LM 7.96 Fencing:Remove any height chainlink fencing complete with

concrete posts and remove waste and debris, fill holes with topsoil and reinstate paving and gardens as necessary.

017411 R FENCING:RESECURE LOOSE CHAINLINK FENCE LM 1.46 Fencing:Resecure any height loose chainlink fencing including

tightening straining wires as necessary.

Fencing - Garden Rail 017501 R FENCING:RENEW GARDEN RAIL 0.575M HIGH LM 33.10 Fencing:Renew with or supply and fix 575mm high tanalised

softwood garden rail fencing comprising 50x225mm horizontal rail splayed on top, bolted to 75x75mm x 0.90m splayed on top posts set in concrete bases at ne 2.00m centres with two (2) 9mm diameter x 150mm galvanised mild steel round head bolts, including excavation, concrete, backfill and remove waste and debris, including where necessary taking down remnants of existing fencing and posts, reinstate paving, gardens and the like as necessary (measured per metre run of fencing).

017503 R FENCING:REMOVE GARDEN RAIL 0.575M HIGH LM 5.77 Fencing:Remove 575mm high garden rail fencing including posts

and remove waste and debris, including fill in post holes with top soil and reinstate paving, gardens and the like as necessary.

Fencing - Hit and Miss 017601 R FENCING:RENEW HIT AND MISS 1.35M HIGH LM 49.07 Fencing:Renew with or supply and fix tanalised softwood hit and

miss fence 1.35m high, comprising 100x100mm posts at ne 1.80m centres, 100x50mm rails, 100x25mm pales to both faces including all excavation, concrete, backfill and remove waste and debris, including where necessary taking down remnants of existing fencing and posts,, reinstate paving, gardens and the like as necessary (measured per metre run of fencing).

Page 50: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

16 Local Space Housing

017603 R FENCING:RENEW HIT AND MISS 1.8M HIGH LM 56.40 Fencing:Renew with or supply and fix tanalised softwood hit and

miss fence 1.80m high, comprising 100x100mm posts at ne 1.80m centres, 100x50mm rails, 100x25mm pales to both faces including all excavation, concrete, 100x25mm pales including all excavation, concrete backfill and remove waste and debris, including where necessary taking down remnants of existing fencing and posts, reinstate paving, gardens and the like as necessary (measured per metre run of fencing).

017604 R FENCING:RENEW HORIZONTAL HIT AND MISS 1.8M HIGH LM 65.12 Fencing:Renew with or supply and fix tanalised softwood horizontal

hit and miss fence 1.80m high, comprising 100x100mm posts at ne 1.20m centres, posts fixed to and including concrete spur posts set in concrete, 100x50mm pales, 150x25mm rails to both faces including all excavation, concrete backfill and remove waste and debris, including where necessary taking down remnants of existing fencing and posts, reinstate paving, gardens and the like as necessary (measured per metre run of fencing).

017609 R FENCING:REMOVE HIT AND MISS LM 10.15 Fencing:Remove any softwood hit and miss type of fencing

including posts and and remove waste and debris, fill post holes with top soil and reinstate paving and gardens as necessary.

Fencing - Palisade 017605 R FENCING:RENEW PALISADE 1.35M HIGH LM 54.01 Fencing:Renew with or supply and fix tanalised softwood palisade

fence 1.35m high with 100x100mm posts at ne 1.80m centres, 100x50mm rails, 75mm pales at 125mm centres including all excavation, concrete, backfill and remove waste and debris, including where necessary taking down remnants of existing fencing and posts, reinstate paving, gardens and the like as necessary (measured per metre run of fencing).

017607 R FENCING:RENEW PALISADE 1.8M HIGH LM 62.86 Fencing:Renew with or supply and fix tanalised softwood palisade

fence 1.80m high with 100x100mm posts at ne 1.80m centres, 100x50mm rails, 75mm pales at 125mm centres including all excavation, concrete, backfill and remove waste and debris, including where necessary taking down remnants of existing fencing and posts, reinstate paving, gardens and the like as necessary (measured per metre run of fencing).

017611 R FENCING:REMOVE PALISADE LM 11.28 Fencing:Remove any palisade type of fencing including posts and

remove waste and debris, fill post holes with top soil and reinstate paving and gardens as necessary.

Fencing - Post and Rail 017651 R FENCING:RENEW POST AND 2 RAIL LM 38.76 Fencing:Renew with or supply and fix tanalised softwood post and

two rail fence with 75x125mm posts at ne 1.80m centres, 100x38mm rails, including all excavation, concrete, backfill and remove waste and debris, including where necessary taking down remnants of existing fencing and posts, reinstate paving, gardens and the like as necessary (measured per metre run of fencing).

Page 51: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

17 Local Space Housing

017653 R FENCING:RENEW POST AND 3 RAIL LM 42.91 Fencing:Renew with or supply and fix tanalised softwood post and

three rail fence with 75x125mm posts at ne 1.80m centres, 100x38mm rails, including all excavation, concrete, backfill and remove waste and debris, including where necessary taking down remnants of existing fencing and posts, reinstate paving, gardens and the like as necessary (measured per metre run of fencing).

Fencing - Post and Wire 017901 R FENCING:ERECT POST AND WIRE 1.2M LM 25.91 Fencing:Erect post and wire fencing 1.20m high with

100x100x1.625m concrete posts cast into concrete with three 2.5mm diameter galvanised mild or plastic coated steel line wires including all fittings, ties etc. and including all excavation, concrete, backfill and remove waste and debris, reinstate paving, gardens and the like as necessary (measured per metre run of fencing).

017903 R FENCING:RENEW WIRES TO EXISTING POSTS 1.2M LM 5.77 Fencing:Renew wire fencing 1.20m high on existing posts, including

removal of old and remove waste and debris, supply and fix three new galvanised or plastic coated steel 2.50mm diameter line wires and all fittings, ties etc. (measured per metre run of fencing).

017905 R FENCING:RENEW OR FIX LINE WIRE LM 2.06 Fencing:Renew or fix new galvanised or PVC coated line wire to

post and wire fence, fix wire to posts including remove and refix fencing as found expedient, remove waste and debris (measured per run of line wire).

Fencing - Concrete Panel 017701 R FENCING:REMOVE PCC POST AND SLAB LM 10.15 Fencing:Remove precast concrete post and slab fencing 1.20m high

and remove waste and debris, fill post holes with top soil and reinstate paving gardens and the like as necessary (measured per metre run of fencing).

Fencing - Sundry Repairs 017801 U FENCING:MAKE SAFE FENCING LM 14.58 Fencing:Make safe any unstable fence and or gate including but not

limited to resecure and or refix fencing, brace and or reset and or refix post, rehang gate or resecure.

017803 R FENCING:RENEW TIMBER PALE AND LAG NO 7.02 Fencing:Renew any type of fencing pale or lag with ne 25x150mm

tanalised timber including all labours, remove waste and debris.

017805 R FENCING:REFIX TIMBER PALE AND LAG NO 2.33 Fencing:Refix any type of fencing pale or lag including remove and

refix as necessary.

017807 R FENCING:FIX GALVANISED REPAIR BRACKET NO 7.36 Fencing:Supply and fix galvanised repair bracket to rail and post

including all cutting and fitting to suit.

Page 52: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

18 Local Space Housing

Fencing - Posts 019001 R FENCE POST:EXCAVATE REMOVE AND MAKE GOOD NO 9.09 Fence Post:Excavate and remove remnants of damaged post with

earth or concrete surround, fill hole with top soil, remove waste and debris, reinstate paving, gardens and the like as necessary.

019003 R FENCE POST:REFIX LOOSE POST NO 10.20 Fence Post:Refix any type of loose post including reset any post set

in earth or concrete without removing and refixing any post fixed to brickwork, concrete and make good.

019005 R FENCE POST:RENEW TIMBER TO HARDCORE OR CONCRETE NO 33.85 Fence Post:Renew tanalised softwood fence post set in hardcore or

concrete size 100x100mm and ne 2.40m long including any struts, excavate hole, place hardcore and or concrete, backfill, remove and refix fencing, remove waste and debris, reinstate paving, gardens and the like as necessary.

019007 R FENCE POST:RENEW TIMBER TO BRICKWORK NO 30.61 Fence Post:Renew tanalised softwood fence post fixed to brickwork

size 100x100mm and ne 2.40m long including remove and refix fencing and or gates and drill plug and screw, remove waste and debris and make good.

019009 R FENCE POST:RENEW TIMBER IN METPOST NO 29.39 Fence Post:Renew 75x75mm tanalised softwood fence post ne

2.40m long with post fixed into driven or bolted Metpost including any struts, remove and refix fencing, remove waste and debris, reinstate paving, gardens and the like as necessary.

019011 R FENCE POST:RENEW PCC NE 1.5M NO 36.81 Fence Post:Renew precast concrete fence post or spur set in

hardcore or concrete ne 100x100mm and ne 1.50m long including any struts, excavate hole, place hardcore and concrete, backfill, remove and refix fencing, remove waste and debris, reinstate paving, gardens and the like as necessary.

019013 R FENCE POST:RENEW PCC OVER 1.5M NO 47.31 Fence Post:Renew precast concrete fence post or spur set in

hardcore or concrete ne 100x100mm and over 1.50m long including any struts, excavate hole, place hardcore or concrete, backfill, remove and refix fencing, remove waste and debris, reinstate paving, gardens and the like as necessary.

019015 R FENCE POST:FIX 50X100MM SW BATTEN NO 17.56 Fence Post:Supply and fix 50x100mm tanalised softwood batten to

precast concrete post ne 1.80m long including drill and bolt batten to post.

019021 R FENCE POST:REPAIR WITH METSPUR NO 19.96 Fence Post:Repair broken post with ‘Metspur’ fitting including

driving spur into ground and bolting to existing post, supply all necessary struts and reinstate paths and gardens on completion, and remove waste and debris.

Page 53: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

19 Local Space Housing

Fencing - Timber Gates 021001 R GATE:RENEW TIMBER NE 1.0SM NO 87.01 Gate:Renew tanalised softwood single leaf gate ne 1.00sm overall,

comprising of two 144x27mm ledges, five 144x20mm vertical boards at 175mm centres and one 144x27mm diagonal brace, including new galvanised steel strap hinges and hangers fixed to existing concrete post, new galvanised mild steel auto catch, prepare for and decorate, remove waste and debris.

021003 R GATE:RENEW TIMBER NE 1.5SM NO 104.18 Gate:Renew tanalised softwood single leaf gate ne 1.50sm overall,

comprising two 144x27mm ledges, five 144x20mm vertical boards at 175mm centres and one 144x27mm diagonal brace, including new galvanised steel strap hinges and hangers fixed to existing concrete post, new galvanised mild steel auto catch, prepare for and decorate, remove waste and debris.

021005 R GATE:RENEW PAIR TIMBER NE 2.5SM OVERALL NO 241.15 Gate:Renew tanalised softwood two leaved gate ne 2.50sm overall,

each leaf comprising two 144x27mm ledges six 144x20mm vertical boards at 175mm centres and one 144x27mm diagonal brace, including new galavanised steel strap hinges and hangers fixed to existing concrete posts, new galvanised mild steel auto catch, prepare for and decorate, remove waste and debris.

021002 R GATE:INSTALL TIMBER NE 1.0SM AND POSTS NO 163.42 Gate:Install tanalised softwood single leaf gate ne 1.00sm overall,

comprising of two 144x27mm ledges, five 144x20mm vertical boards at 175mm centres and one 144x27mm diagonal brace, including galvanised steel strap hinges and hangers fixed to and including precast concrete posts ne 1.65m long, galvanised mild steel auto catch, prepare for and decorate, posts set in concrete including all excavation, concrete, backfill, and remove waste and debris, reinstate paving, gardens and the like as necessary.

021004 R GATE:INSTALL TIMBER NE 1.5SM AND POSTS NO 187.40 Gate:Install tanalised softwood single leaf gate ne 1.50sm overall,

comprising two 144x27mm ledges, five 144x20mm vertical boards at 175mm centres and one 144x27mm diagonal brace, including galvanised steel strap hinges and hangers fixed to and including precast concrete posts ne 2.15m long, galvanised mild steel auto catch, prepare for and decorate, posts set in concrete including all excavation, concrete, backfill, and remove waste and debris, reinstate paving, gardens and the like as necessary.

021006 R GATES:INSTALL PAIR TIMBER NE 2.5SM AND POST NO 317.56 Gates:Install tanalised softwood two leaved gate ne 2.5sm overall,

each leaf comprising two 144x27mm ledges, six 144x20mm vertical boards at 175mm centres and one 144x27mm diagonal brace, including steel strap hinges and hangers fixed to and including precaste concrete posts, galvanised mild steel auto catch, prepare for and decorate, posts set in concrete including all excavation, concrete, backfill and remove waste and debris, reinstate paving, gardens and like as necessary.

Page 54: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

20 Local Space Housing

021007 R GATE:REPAIR AND EASE AND ADJUST TIMBER GATE NO 26.93 Gate:Repair any damaged timber gate including ease and adjust,

remove and rehang as necessary including adjust stop, supply and fix new timbers and scarf new sections as required and redecorate to match existing.

021013 R GATE:RENEW GATE AND FENCE CAPPING LM 5.06 Gate:Renew any type and size of gate or fence capping with

softwood tanalised capping to match and redecorate to match existing, remove waste and debris.

021021 R GATE:INSTALL TIMBER PANEL 1.2M HIGH NO 102.75 Gate:Install tanalised softwood single leaf gate comprising 0 90m

wide x 1.20m high interwoven or overlap panel with additional diagonal brace, including galvanised steel hinges fixed to and including 100x100mm treated softwood posts ne 1.85m long, galvanised mild steel auto catch, prepare for and decorate, posts set in concrete including all excavation, concrete, backfill, and remove waste and debris, reinstate paving, gardens and the like as necessary.

021023 R GATE:INSTALL TIMBER PANEL 1.8M HIGH NO 116.78 Gate:Install tanalised softwood single leaf gate comprising 0.90m

wide x 1.80m high interwoven or overlap panel with additional diagonal brace, including galvanised steel hinges fixed to and including 100x100mm treated softwood posts ne 2.45m long, galvanised mild steel auto catch, prepare for and decorate, posts set in concrete including all excavation, concrete, backfill, and remove waste and debris, reinstate paving, gardens and the like as necessary.

Fencing - Metal Gates 023001 R GATE:RENEW METAL NE 1.0SM NO 85.86 Gate:Renew galvanised mild steel gate ne 1.00sm, overall

consisting of 25x25x3mm angle frame with corners mitred and welded and seven 10x10mm balusters with ends welded to frame, including sliding bolt, stop and one pair of hanging lugs fixed to brickwork or concrete, prepare for and decorate, remove waste and debris.

023003 R GATE:RENEW METAL NE 2.0SM NO 177.56 Gate:Renew galvanised mild steel gate ne 2.00sm overall consisting

of 25x25x3mm angle frame with corners mitred and welded and seven 10x10mm balusters with ends welded to frame, including sliding bolt, stop and one pair of hanging lugs fixed to brickwork or concrete, prepare for and decorate, remove waste and debris.

023009 R GATE:REPAIR AND EASE AND ADJUST METAL GATE NO 18.96 Gate:Ease and adjust any metal gate including remove and refix

and carry out any minor repairs and or adjustments as necessary, make good paintwork to match existing.

Page 55: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

21 Local Space Housing

Fencing - Gate Posts 025001 R GATE POST:RENEW TIMBER NO 59.08 Gate Post:Renew gate post with tanalised softwood post, post size

100x125mm, set in concrete, including all excavation, concrete, backfill and remove waste and debris, reinstate paving, gardens and the like as necessary, remove and refix fencing and gates as necessary, transfer existing latch keep or gudgeon pins, redecorate to match existing.

025003 R GATE POST:RENEW PCC NO 40.00 Gate Post:Renew gate post with precast concrete ne 1.65m long, set in

concrete, including all excavation, concrete, backfill and remove waste and debris, reinstate paving, gardens and the like as necessary, remove and refix fencing and gates as necessary, transfer existing latch keep or gudgeon pins.

025005 R GATE FRAME:RENEW TIMBER LM 32.25 Gate Frame:Renew gate frame with tanalised softwood gate frame,

including plug and screw frame to brickwork and redecorate to match existing, remove waste and debris.

025011 R GATE POST:RENEW OR SUPPLY ANCHOR POST NO 44.20 Gate Post:Renew or supply and fix new gate anchor post of any type and

size complete with all clips and fastenings, set in concrete, including all excavation, concrete, backfill, and remove waste and debris, reinstate paving, gardens and the like as necessary, remove and refix fencing and gates as necessary

021011 R GATE:RENEW 50X25MM STOP NE 2.0M NO 8.39 Gate:Renew 50x25mm tanalised softwood gate stop ne 2.00m long

fixed to gate frame and redecorate to match existing, remove waste and debris.

019018 R GATE POST AND GATE:RENEW AND REPAIR ANY FITTING NO 14.55 Gate Post and Gate:Renew or repair any single fitting to post or

timber or metal gate including any gate hinge, gudgeon, band, pivot plate or pivot socket, spring, any post or gate catch or bolt, remove waste and debris (measured per complete fitting).

Page 56: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

22 Local Space Housing

DRAINAGE Drainage Below Ground Drainage - New - Clay Pipes 033101 R DRAIN:INSTALL 100MM CLAY NE 1M DEEP LM 120.99 Drain:Excavate not exceeding 1.00m deep, level and compact

bottoms of excavations, 150mm thick concrete bed and lay 100mm diameter clay pipe and haunch up in concrete and backfill, remove waste and debris, including all connections, junctions and bends, allow for exposing, breaking out and removal of any existing drains including concrete beds and surrounds and all connections to existing pipework, testing.

033103 R DRAIN:INSTALL 100MM CLAY 1-2M DEEP LM 204.89 Drain:Excavate exceeding 1.00m and ne 2m deep, level and

compact bottoms of excavations, 150mm thick concrete bed and lay 100mm diameter clay pipe and haunch up in concrete and backfill, remove waste and debris, including all connections, junctions and bends, allow for exposing, breaking out and removal of any existing drains including concrete beds and surrounds and all connections to existing pipework, testing.

Drainage - New - Plastic Pipes 033301 R DRAIN:INSTALL 110MM PVCU NE 1M DEEP LM 117.95 Drain:Excavate not exceeding 1.00m deep, level and compact

bottoms of excavations, 100mm thick bed of gravel and lay 110mm diameter PVCu pipe and backfill 210mm with selected granular material, compacted by hand and backfill, remove waste and debris, including all bends, fittings, connections etc, allow for removal of any existing drains including concrete beds and surrounds and all connections to existing pipework, testing.

033303 R DRAIN:INSTALL 110MM PVCU 1-2M DEEP LM 198.92 Drain:Excavate exceeding 1.00m and ne 2.00m deep level and

compact bottoms of excavations, 100mm thick bed of gravel and lay 110mm diameter PVCu pipe and backfill 210mm with selected granular material, compacted by hand and backfill, remove waste and debris, including all bends, fittings, connections etc, allow for removal of any existing drains including concrete beds and surrounds and all connections to existing pipework, testing.

Drainage - Existing - Repairs 033501 R DRAIN:REPAIR 100MM PIPE NE 1M DEEP NO 272.07 Drain:Repair by locating damaged pipe, excavate not exceeding

1.00mm deep, for a length not exceeding 3.00m, remove pipe, concrete bed and surround and level and compact bottoms of excavations, 150mm thick concrete, bed and lay 100mm diameter clay pipe and backfill, include for all adaptors, junctions and bends, remove waste and debris and all connections to existing pipework, testing.

Page 57: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

23 Local Space Housing

033503 R DRAIN:REPAIR 100MM PIPE 1-2M DEEP NO 442.76 Drain:Repair by locating damaged pipe, excavate over 1.00m not

exceeding 2.00m deep, for a length not exceeding 3.00m, remove pipe, concrete bed and surround and level and compact bottoms of excavations, 150mm thick concrete, bed and lay 100mm diameter clay pipe and backfill, include for all adaptors, junctions and bends, remove waste and debris and all connections to existing pipework testing.

033505 R DRAIN:REPAIR 150MM PIPE NE 1M DEEP NO 312.87 Drain:Repair by locating damaged pipe, excavate not exceeding

1.00m deep, for a length not exceeding 3.00m, remove pipe, concrete bed and surround and level and compact bottoms of excavations, 150mm thick concrete bed and lay 150mm diameter clay pipe and backfill, include for all adaptors, junctions and bends, remove waste and debris and all connections to existing pipework, testing.

033507 R DRAIN:REPAIR 150MM PIPE 1-2M DEEP NO 476.99 Drain:Repair by locating damaged pipe, excavate over 1.00m not

exceeding 2.00m deep, for a length not exceeding 3.00m, remove pipe, concrete bed and surround and level and compact bottoms of excavations, 150mm thick concrete, bed and lay 150mm diameter clay pipe and backfill, include for all adaptors, junctions and bends, remove waste and debris and all connections to existing pipework, testing.

Gullies 035001 R GULLY:INSTALL CLAY BACK INLET GULLY NO 146.23 Gully:Excavate, level and compact bottoms and set any type of

vitrified clay gully with 100mm back inlet and grating including setting and surrounding in concrete, backfill, remove waste and debris, and reinstate paving, gardens and the like as necessary, testing.

035003 R GULLY:INSTALL PVCU BACK INLET GULLY NO 88.71 Gully:Excavate, level and compact bottoms and set any type of

PVCu gully with 100mm back inlet and grating including setting and surrounding in concrete, backfill, remove waste and debris, and reinstate paving, gardens and the like as necessary, testing.

035005 R GULLY:REMOVE AND SEAL OFF AND MAKE GOOD NO 15.88 Gully:Excavate, remove existing gully (any type) seal pipe, backfill

and make good, remove waste and debris, and reinstate paving, gardens and the like as necessary.

035007 R GULLY:RENEW ANY TYPE SURROUND AND KERB NO 21.34 Gully:Renew precast concrete or brick gully surround or kerb

bedded in cement mortar (1:4) including breaking up existing and remove waste and debris, and reinstate paving, gardens and the like as necessary.

035009 R GULLY:RENEW GRATING NO 15.60 Gully:Renew missing or damaged any size or type of gully grating,

remove waste and debris.

035013 R GULLY:RENEW INSPECTION PLATE NO 33.73 Gully:Renew missing or damaged any size or type of screwed down

inspection plate to gully or rodding eye, remove waste and debris.

Page 58: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

24 Local Space Housing

Extra Over for Breaking Out and Reinstatement 047001 U MAIN AND DRAIN:REINSTATE CONCRETE PAVING LM 56.55 Main and Drain:Extra for breaking up, remove waste and debris and

subsequently reinstating not exceeding 150mm thick concrete with hardcore sub-base under, not exceeding 600mm wide including joints and make good to existing finishes.

047003 U MAIN AND DRAIN:REINSTATE MACADAM PAVING LM 33.11 Main and Drain:Extra for breaking up, remove waste and debris and

subsequently reinstating not exceeding 100mm thick tarmacadam with hardcore sub-base under, not exceeding 600mm wide including joints and make good to existing finishes.

047005 U MAIN AND DRAIN:REINSTATE FLAG PAVING LM 10.73 Main and Drain:Extra for lifting, set aside and subsequently relaying

flag paving and sub-base grout and point, not exceeding 600mm wide including any extra cutting and bonding to existing paving.

047007 U MAIN AND DRAIN:REINSTATE BRICK PAVING LM 46.62 Main and Drain:Extra for lifting, set aside and subsequently relaying

brick paviors and sub-base grout and point, not exceeding 600mm wide including all bonding to existing paving.

Manholes Manholes - Brick 037001 R MANHOLE:CONSTRUCT NEW BRICK NE 1.35M DEEP IT 974.50 Manhole:Construct manhole ne 1.35m deep to invert level in semi

engineering bricks 225mm thick with 150mm thick concrete base, 100mm thick reinforced precast concrete cover slab, cover with frame bedded in cement mortar, build in ends of pipes and bed in all required channels, bends etc, testing, allow for all excavation, earth support, backfill and remove waste and debris, and reinstate paving, gardens and the like as necessary.

037003 R MANHOLE:RENEW BRICK NE 1.35M DEEP IT 1011.15 Manhole:Renew manhole ne 1.35m deep to invert level in semi

engineering bricks 225mm thick with 150mm thick concrete base, 100mm thick reinforced precast concrete cover slab, cover with frame bedded in cement mortar, build in ends of pipes and bed in all required channels, bends etc, testing, allow for breaking out of existing manhole including any extra excavation required, all diversions to existing services, earth support, backfill and remove waste and debris, and reinstate paving, gardens and the like as necessary.

Inspection Chambers - Polypropylene 037005 R INSPECTION CHAMBER:NEW SHALLOW POLYPROPYLENE IT 118.93 Inspection Chamber:Construct polypropylene shallow inspection

chamber ne 600mm deep for 110mm diameter PVCu pipe including cover and frame, connections to all pipework, testing and allow for all excavation, earth support, backfill and remove waste and debris, and reinstate paving, gardens and the like as necessary.

Page 59: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

25 Local Space Housing

037007 R INSPECTION CHAMBER:RENEW SHALLOW POLYPROPYLENE IT 142.55 Inspection Chamber:Renew polypropylene shallow inspection

chamber ne 600mm deep for 110mm diameter PVCu pipe including cover and frame, connections to all pipework, testing and allow for all excavation, earth support, backfill and remove waste and debris, and reinstate paving, gardens and the like as necessary, allow for breaking out existing including any extra excavation etc. required and all temporary diversions to existing services.

037009 R INSPECTION CHAMBER:NEW UNIVERSAL POLYPROPYLENE IT 216.76 Inspection Chamber:Construct polypropylene universal inspection

chamber ne 1000mm deep for 110mm diameter PVCu pipe including cover and frame, connections to all pipework, testing and allow for all excavation, earth support, backfill and remove waste and debris, and reinstate paving, gardens and the like as necessary.

037011 R INSPECTION CHAMBER:RENEW UNIVERSAL POLYPROPY IT 235.86 Inspection Chamber:Renew polypropylene universal inspection

chamber ne 1000mm deep for 110mm diameter PVCu pipe including cover and frame, connections to all pipework, testing and allow for all excavation, earth support, backfill and remove waste and debris, and r einstate paving, gardens and the like as necessary, allow for breaking out existing including any extra excavation etc. required and all temporary diversions to existing services.

Manhole - Covers and Slabs 037013 R MANHOLE:RENEW PCC COVER SLAB NO 80.65 Manhole:Renew precast cover slab not exceeding

1000x1500x100mm thick including bed in cement mortar (1:3), remove waste and debris, and reinstate paving, gardens and the like as necessary.

037017 R MANHOLE:REBED COVER AND OR FRAME NO 18.99 Manhole:Lift and rebed existing cover and frame, bed frame in

cement mortar (1:3) including any breaking out of foundation required to ensure correct levels clean off cover and replace including reset in grease.

037019 R MANHOLE:RENEW COVER LIGHT GRADE NO 25.91 Manhole:Renew manhole cover and frame, light duty single seal,

any size including bed frame in cement mortar (1:3), remove waste and debris, and reinstate paving, gardens and the like as necessary.

037021 R MANHOLE:RENEW COVER MEDIUM GRADE NO 36.41 Manhole:Renew manhole cover and frame, medium duty, single

seal, any size including bed frame in cement mortar (1:3), remove waste and debris, and reinstate paving, gardens and the like as necessary.

037027 R MANHOLE:RENEW COVER LIGHT INTERNAL NO 75.78 Manhole:Renew manhole cover and frame with stainless steel

double seal light duty recessed inspection cover and frame any size including bed frame in cement mortar (1:3) and fill recessed cover with screed and floor finish to match existing, remove waste and debris, and reinstate flooring as necessary.

Page 60: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

26 Local Space Housing

037029 R INSPECTION COVER:RENEW-300X300MM NO 47.65 Inspection Cover:Renew galvanised inspection cover and frame size

300x300mm including bed frame in cement mortar (1:3), remove waste and debris, and reinstate paving, gardens and the like as necessary.

Clearing Blockages, CCTV and Testing Clearing Blockages 039003 E GULLY:CLEAN FLUSH OUT CLEAR BLOCKAGE NO 11.82 Gully:Clear blockage to gully including rodding as necessary, flush

with clean water and remove waste and debris.

039004 E DRAIN:JET BLOCKAGE HR 68.25 Drain:Clear blocked drain run by pressure jet, remove and refix

manhole covers and gratings, attend upon Client Representative during any inspection, including all hire charges and any temporary relocation, remove on completion, flush out, test and remove waste and debris (to be charged for hours worked on site only, rate includes for travelling and other non- productive time).

039006 E DRAIN:ROD BLOCKAGE IT 26.26 Drain:Rod blocked drain run by rodding, remove and refix manhole

covers and gratings as necessary, flush out, test and remove waste and debris.

039009 E MANHOLE:CLEAR BLOCKAGE NE 3.0M DEEP IT 13.13 Manhole:Clear out debris to manhole not exceeding 3.00m deep

and remove from site, and flush out and test and remove waste and debris.

CCTV Drains 039015 E DRAIN:CCTV SURVEY HR 68.25 Drain:Undertake CCTV survey of drain runs to identify fault or

following repairs or jetting, remove and refix manhole covers and gratings as necessary, including all hire charges and any temporary relocation, remove on completion, supply report and video to Client Representative (to be charged for hours worked on site, rate includes for travelling and other non-productive time)

Drain Testing 039018 E TEST:SMOKE OR PRESSURE TEST IT 32.44 Test:Carry out smoke or pressure test to existing drain run and

report to Client Representative (not to be claimed in association with any other works).

Land Drainage and Soakaways Land Drainage 041001 R LAND DRAIN:75MM NE 2.0M DEEP LM 263.59 Land Drain:Excavate trench maximum 630mm wide over 1.00m not

exceeding 2.00m deep, remove waste and debris, lay 50mm granular bed, 75mm concrete land drain pipe and matting, backfill trench in stone to within 200mm of existing ground level, level with topsoil, include for all necessary bends, junctions and connections.

Page 61: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

27 Local Space Housing

Soakaways 041005 R SOAKAWAY:EXCAVATE NEW CM 204.65 Soakaway:Excavate for new soakaway ne 2.00m deep, lift turf and

set aside, excavate soakaway, remove excavated material to temporary spoil heap where directed, fill excavation with hard, dry, broken, masonry, stone or gravel ne 100mm gauge to within 250mm of existing ground level, backfill as necessary with excavated material from temporary debris heap, remove waste and debris from temporary spoil heap, relay turfs.

041007 R SOAKAWAY:CLEAR EXISTING CM 204.65 Soakaway:Excavate to locate soakaway ne 2.00m deep, lift turf and

set aside, excavate soakaway, remove excavated material to temporary spoil heap where directed, clear debris from soakaway, refill with new and existing soakaway medium to within 250mm of existing ground level, backfill with excavated material from temporary debris heap, remove waste and debris from temporary spoil heap, relay turfs.

Page 62: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

28 Local Space Housing

BRICKWORK Brick/Block Walling Walls - Demolition 101101 R WALL:DEMOLISH EXTERNAL 1/2B WALL SM 19.35 Wall:Take down external half brick wall and remove waste and

debris.

101103 R WALL:DEMOLISH EXTERNAL 1B WALL SM 32.07 Wall:Take down external one brick wall and remove waste and

debris.

101105 R WALL:DEMOLISH EXTERNAL 1-1/2B WALL SM 52.24 Wall:Take down external one and a half brick wall and remove

waste and debris.

101107 R WALL:DEMOLISH EXTERNAL CAVITY WALL SM 30.44 Wall:Take down external cavity wall and remove waste and debris. 101109 R WALL:DEMOLISH EXTERNAL BLOCKWORK NE 100MM SM 13.28 Wall:Take down ne 100mm thick external block wall and remove

waste and debris.

101111 R WALL:DEMOLISH EXTERNAL BLOCKWORK NE 225MM SM 23.32 Wall:Take down exceeding 100mm and ne 225mm thick external

block wall and remove waste and debris.

101121 R WALL:DEMOLISH PLASTERED 1/2B WALL SM 33.28 Wall:Take down half brick or 100mm blockwork non-load bearing

wall and remove waste and debris, including associated doors, frames, skirtings, plaster etc., make good the existing structure at intersection with internal and external walls, make good to existing floor and screeds, plaster ceiling and skirtings.

101123 R WALL:DEMOLISH PLASTERED 1B WALL SM 53.10 Wall:Take down one brick or over 100mm and ne 225mm

blockwork non-load bearing wall and remove waste and debris, including associated doors, frames, skirtings, plaster etc., make good the existing structure at intersection with internal and external walls, make good to existing floor/screeds, plaster ceiling and skirtings.

Walls - Construction 101301 R WALL:BUILD 1/2B WALL IN COMMONS SM 69.64 Wall:Supply and lay new common bricks in half brick wall bedded

and pointed in cement lime mortar (1:1:6).

101303 R WALL:BUILD 1B WALL IN COMMONS SM 121.36 Wall:Supply and lay new common bricks in one brick wall bedded

and pointed in cement lime mortar (1:1:6).

101305 R WALL:BUILD 1-1/2B WALL IN COMMONS SM 172.91 Wall:Supply and lay new common bricks in one and a half brick wall

in cement lime mortar (1:1:6).

Page 63: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

29 Local Space Housing

101307 R WALL:BUILD CAVITY WALL IN COMMONS SM 131.29 Wall:Supply and lay new common bricks in cavity wall to match

existing, bedded and pointed in cement lime mortar (1:1:6) including form cavity with 5 No. wall ties per square metre.

101309 R WALL:BUILD 1/2B WALL IN FACINGS SM 96.71 Wall:Supply and lay new facing bricks in half brick wall bedded and

pointed in cement lime mortar (1:1:6) as the work proceeds.

101311 R WALL:BUILD 1B WALL IN FACINGS SM 173.30 Wall:Supply and lay new facing bricks in one brick wall bedded and

pointed in cement lime mortar (1:1:6) as the work proceeds.

101313 R WALL:BUILD CAVITY WALL IN FACINGS SM 176.67 Wall:Supply and lay new facing bricks in cavity wall to match

existing, bedded and pointed in cement lime mortar (1:1:6) as the work proceeds including form cavity with 5 No. wall ties per square metre.

101317 R WALL:BUILD NE 100MM BLOCK WALL SM 41.56 Wall:Supply and lay new ne 100mm thick blockwork in walls,

bedded and pointed in cement lime mortar (1:1:6).

101319 R WALL:BUILD 225MM BLOCK WALL SM 72.17 Wall:Supply and lay new 225mm thick blockwork in walls, bedded

and pointed in cement lime mortar (1:1:6).

Walls - Rebuilding 101501 R WALL:REBUILD 1/2B WALL IN COMMONS SM 82.77 Wall:Demolish as necessary, clean off and clear away, rebuild half

brick wall, in common bricks bed and point in cement lime mortar (1:1:6) to match existing and remove waste and debris.

101503 R WALL:REBUILD 1B WALL IN COMMONS SM 145.43 Wall:Demolish as necessary, clean off and clear away, rebuild one

brick wall in common bricks, bed and point in cement lime mortar (1:1:6) to match existing and remove waste and debris.

101505 R WALL:REBUILD 1/2B WALL IN FACINGS SM 112.03 Wall:Demolish as necessary, clean off and clear away, rebuild half

brick wall, in facing bricks bed and point in cement lime mortar (1:1:6) to match existing, and remove waste and debris..

101507 R WALL:REBUILD 1B WALL IN FACINGS SM 195.18 Wall:Demolish as necessary, clean off and clear away, rebuild one

brick wall in facing bricks, bed and point in cement lime mortar (1:1:6) to match existing, and remove waste and debris.

101511 R WALL:REBUILD NE 100MM BLOCK WALL SM 48.12 Wall:Demolish as necessary, clean off and clear away, rebuild ne

100mm blockwork in cement lime mortar (1:1:6) bed and point to match existing, and remove waste and debris.

101513 R WALL:REBUILD 225MM BLOCK WALL SM 78.73 Wall:Demolish as necessary, clean off and clear away, rebuild

225mm blockwork in cement lime mortar (1:1:6) bed and point to match existing, and remove waste and debris.

Page 64: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

30 Local Space Housing

101515 R FIREWALL:REBUILD 1B WALL IN COMMONS SM 176.06 Firewall:Demolish as necessary, clean off, clear away and rebuild

one brick firewall in roof space, in common bricks, bed and point in cement lime mortar (1:1:6) to match existing, and remove waste and debris.

101517 R CHIMNEY BREAST:REBUILD IN ROOF SPACE SM 176.06 Chimney Breast:Demolish as necessary, clean off, clear away and

rebuild chimney breast in roof space, in common bricks, bed and point in cement lime mortar (1:1:6) to match existing, and remove waste and debris.

Piers 101701 R PIER:REBUILD 1B WIDE ATTACHED IN COMMONS LM 27.97 Pier:Demolish as necessary, clean off and clear away, rebuild

attached pier in common bricks, one brick wide x half brick projection, bedded and pointed in cement lime mortar (1:1:6) to match existing, and remove waste and debris.

101703 R PIER:REBUILD 1B ISOLATED IN COMMONS LM 98.00 Pier:Demolish as necessary, clean off and clear away, rebuild one

brick isolated pier in common bricks with brick on edge coping, bedded and pointed in cement lime mortar (1:1:6) to match existing including building in any gudgeons, gate keeps or similar built in items and remove waste and debris.

101705 R PIER:REBUILD 1-1/2B WIDE ATTACHED IN COMMONS LM 48.67 Pier:Demolish as necessary, clean off and clear away, rebuild

attached pier in common bricks, one and a half brick wide, half brick projection, bedded and pointed in cement lime mortar (1:1:6) to match existing, and remove waste and debris.

101707 R PIER:REBUILD 1-1/2B ISOLATED IN COMMONS LM 132.65 Pier:Demolish as necessary, clean off and clear away, rebuild one

and a half brick isolated pier in common bricks with brick on edge coping, bedded and pointed in cement lime mortar (1:1:6) to match existing including building in any gudgeons, gate keeps or similar built in items and remove waste and debris.

101709 R PIER:REBUILD 1B WIDE ATTACHED IN FACINGS LM 38.98 Pier:Demolish as necessary, clean off and clear away, rebuild

attached pier in facing bricks. one brick wide, half brick projection, bedded and pointed in cement lime mortar (1:1:6) to match existing, and remove waste and debris.

101711 R PIER:REBUILD 1B ISOLATED IN FACINGS LM 111.20 Pier:Demolish as necessary, clean off and clear away, rebuild one

brick isolated pier in facing bricks with brick on edge coping, bedded and pointed in cement lime mortar (1:1:6) to match existing including building in any gudgeons, gate keeps or similar built in items and remove waste and debris.

101713 R PIER:REBUILD 1-1/2B WIDE ATTACHED IN FACINGS LM 64.18 Pier:Demolish as necessary, clean off and clear away, rebuild

attached pier in facing bricks, one and a half brick wide, half brick projection, bedded and pointed in cement lime mortar (1:1:6) to match existing, and remove waste and debris.

Page 65: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

31 Local Space Housing

101715 R PIER:REBUILD 1-1/2B ISOLATED IN FACINGS LM 157.86 Pier:Demolish as necessary, clean off and clear away, rebuild one

and a half brick isolated pier in facing bricks with brick on edge coping, bedded and pointed in cement lime mortar (1:1:6) to match existing including building in any gudgeons, gate keeps or similar built in items and remove waste and debris.

Brick/Block Repairs 101901 R WALL:REPAIR FRACTURE LM 60.21 Fracture:Remove any applied finish and cut out bricks as necessary

to either side of fracture, one face only, stitch in new bricks, bed and point to match existing in cement lime mortar (1:1:6), and make good any applied finishes, and remove waste and debris. (measured over mean general line of fracture).

101903 R WALL:REPAIR SMALL PATCH IN COMMONS IT 25.73 Wall:Cut out bricks from face of wall, clean and clear away, lay

upto 15 No. new common bricks in cement lime mortar (1:1:6), bond, bed and point to match existing and remove waste and debris.

101905 R WALL:REPAIR LARGE PATCH IN COMMONS IT 132.65 Wall:Cut out bricks from face of wall, clean and clear away, lay over

15 No. new common bricks upto 2sm in area in cement lime mortar (1:1:6), bond, bed and point to match existing and remove waste and debris.

101907 R WALL:REPAIR SMALL PATCH IN FACINGS IT 29.57 Wall:Cut out bricks from face of wall, clean and clear away, lay

upto 15 No. new facing bricks in cement lime mortar (1:1:6), bond, bed and point to match existing and remove waste and debris.

101909 R WALL:REPAIR LARGE PATCH IN FACINGS IT 153.48 Wall:Cut out bricks from face of wall, clean and clear away, lay over

15 No. new facing bricks upto 2sm in area in cement lime mortar (1:1:6), bond, bed and point to match existing and remove waste and debris.

101911 R WALL:RENEW INDIVIDUAL 100MM BLOCK NO 7.49 Wall:Cut out old 100mm block, clean and clear away, supply and

lay new block in cement lime mortar (1:1:6), bond, bed and point to match existing and remove waste and debris. (first block).

101913 R WALL:RENEW SUBSEQENT 100MM BLOCKS NO 5.30 Wall:Cut out old 100mm block, clean and clear away, supply and

lay new block in cement lime mortar (1:1:6), bond, bed and point to match existing and remove waste and debris. (subsequent blocks).

101915 R WALL:RENEW INDIVIDUAL 225MM BLOCK NO 13.15 Wall:Cut out old 225mm block, clean and clear away, supply and

lay new block in cement lime mortar (1:1:6), bond, bed and point to match existing and remove waste and debris. (first block).

101917 R WALL:RENEW SUBSEQENT 225MM BLOCKS NO 10.96 Wall:Cut out old 225mm block, clean and clear away, supply and

lay new block in cement lime mortar (1:1:6), bond, bed and point to match existing and remove waste and debris. (subsequent blocks).

Page 66: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

32 Local Space Housing

Repointing 102103 R WALL:RAKE OUT AND REPOINT BRICKWORK SM 27.86 Wall:Rake out existing joints of brickwork minimum 12mm deep

and repoint brickwork in mortar to match existing and remove waste and debris.

102105 R WALL:RAKE OUT AND REPOINT JOINT OF BRICKWORK LM 3.66 Wall:Rake out existing mortar joint as necessary min 12mm and

repoint in mortar to match existing in joints to cills, sides of door/window frames or concrete cladding joints etc and remove waste and debris.

Tell Tales 102301 R TELL TALE:BED IN GLASS TELL TALE NO 13.01 Tell Tale:Hack out cement joint in brickwork and provide and bed in

glass tell tale in cement mortar (1:3).

Cavities 102503 R WALL:CLEAR CAVITY-AREAS NE 1.0SM IT 71.69 Wall:Cut out bricks in areas ne 1sm for access into cavity, clear

blockage including upto 0.5m from opening in any direction, take all necessary measures to prevent loss of any cavity insulation, remove and remove waste and debris, reinstate and make good cavity insulation to match existing as necessary, clean and replace bricks and bed and point in cement lime mortar (1:1:6) to match existing.

Openings - Minor 102719 R HOLE:MAKE GOOD HOLE ANY DIAMETER NO 7.00 Hole:Make good any diameter hole after removal or around any

diameter existing pipe passing through brick/block wall, remove waste and debris, including make good finishes.

102721 R HOLE:HOLE FOR CAVITY INSPECTION NO 3.79 Hole:Drill hole through half brick skin of cavity wall for purpose of

boroscope inspection of cavity, remove waste and debris, and make good on completion (inspection undertaken by others).

Openings - Internal Door 102731 R OPENING:FORM IN 1/2B INTERNAL WALL FOR DOOR IT 160.21 Opening:Cut or form opening for internal door and frame in half

brick wall plastered both sides, insert concrete lintol and quoin up jambs, make good plaster, extend flooring through opening on bearers, make good all works disturbed including decorations, temporary propping and remove waste and debris.

102733 R OPENING:FORM IN 1B INTERNAL WALL FOR DOOR IT 216.52 Opening:Cut or form opening for internal door and frame in one

brick wall plastered both sides, insert concrete lintol and quoin up jambs, make good plaster, extend flooring through opening on bearers, make good all works disturbed including decorations, temporary propping and and remove waste and debris.

Page 67: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

33 Local Space Housing

102741 R OPENING:BUILD UP INTERNAL IN 100MM BLOCKS IT 178.80 Opening:Build up internal door opening in 100mm blockwork,

bedded and pointed in mortar to match existing, including prepare opening, cut tooth and bond jambs to receive blockwork, finished both sides with 2 coats of lightweight gypsum plaster finished flush with existing, including any necessary dubbing out, make good all works disturbed including decorations, and remove waste and debris

102743 R OPENING:BUILD UP INTERNAL IN COMMONS 1/2B THICK IT 234.72 Opening:Build up internal door opening in commons, half brick

thick, bedded and pointed in mortar to match existing, including prepare opening, cut tooth and bond jambs to receive brickwork, wedge and pinned to soffit, finished both sides with 2 coats of lightweight gypsum plaster finished flush with existing, including any necessary dubbing out, make good all works disturbed including decorations, and remove waste and debris.

102745 R OPENING:BUILD UP INTERNAL IN COMMONS 1B THICK IT 350.94 Opening:Build up internal door opening in commons, one brick

thick, bedded and pointed in mortar to match existing, including prepare opening, cut tooth and bond jambs to receive brickwork, wedge and pinned to soffit, finished both sides with 2 coats of lightweight gypsum plaster finished flush with existing, including any necessary dubbing out, make good all works disturbed including decorations, and remove waste and debris.

Openings - External Door/Window 102751 R OPENING:FORM DOOR IN EXTERNAL WALL SM 219.35 Opening:Cut or form opening for door exceeding 1.00sm in 275mm

cavity wall, insert catnic lintol type CN7 or other equal and approved, damp proof course flashing, quoin up and close cavity at jambs with brickwork to match existing, form brick-on-end arch soldier course, form brick-on-end step with class B engineering bricks, snap headers, damp proof course to jambs and cill face up margins to match existing, make good plasterwork and decorations internally, include for additional stainless steel wall ties at 300mm centres around opening, propping and temporary supports, and remove waste and debris

102753 R OPENING:FORM WINDOW IN EXTERNAL WALL SM 278.79 Opening:Cut or form opening for window exceeding 1.00sm in

275mm cavity wall, insert catnic lintol CN7 or other equal and approved, damp proof course flashing, quoin up and close cavity at jambs with brickwork to match existing, form brick-on-end arch soldier course, form cill with two course of plain tile creasing, set on brick on edge snap headers, damp proof course to jambs and cill face up margins to match existing, make good plasterwork and decorations internally, include for additional stainless steel wall ties at 300mm centres around opening, propping and temporary supports, and remove waste and debris.

Page 68: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

34 Local Space Housing

102761 R OPENING:ENLARGE EXISTING WINDOW SM 248.38 Opening:Cut out and reform opening for window exceeding 1.00sm

in 275mm cavity wall, insert catnic lintol type CN7 or other equal and approved, damp proof course flashing, quoin up and close cavity at jambs with brickwork to match existing, form brick-on-end arch solider course, form cill with two course of plain tile creasing, set on brick on edge snap headers, damp proof course to jambs and cill face up margins to match existing, make good plasterwork and decorations internally, include for additional stainless steel wall ties at 300mm centres around opening, propping and temporary supports, and remove waste and debris.

102763 R OPENING:ADAPT EXTERNAL DOOR TO WINDOW IT 175.61 Opening:Remove existing door frame, adapt opening for window

exceeding 1.00sm in 275mm cavity wall, and close cavity at cill with slate, brick up opening below cill level with facing bricks to match existing and concrete blockwork internally, form cill with two courses of plain tile creasing, set on brick on edge snap headers, damp proof course to jambs and cill face up margins to match existing, make good plasterwork and decorations internally, include for additional stainless steel wall ties at 300mm centres around opening, propping and temporary supports, and remove waste and debris.

102765 R OPENING:CONVERT OR EXTEND DOOR INTO WINDOW SM 271.89 Opening:Remove existing door frame, cut or form opening for

window exceeding 1.00sm in 275mm cavity wall, insert catnic lintol type CN7, or other equal and approved, damp proof course flashing, quoin up and close cavity at jambs with brickwork to match existing, form or extend brick-on-end arch soldier course, brick up opening below cill level with facing bricks to match existing and concrete blockwork internally, close cavity at cill with slate, form cill with two courses of plain tile creasing, set on brick on edge snap headers, damp proof course to jambs and cill face up margins to match existing, make good plasterwork and decorations internally, include for additional stainless steel wall ties at 300mm centres around opening, propping and temporary supports, and remove waste and debris

102771 R OPENING:BUILD UP EXTERNAL IN COMMONS SM 147.50 Opening:Build up existing opening for door or window, remove door

or window frame, tiled cill, concrete cill, internal lintol, flat brick on edge arch over, build up externally in common bricks in mortar, allow for cutting, toothing and bonding into existing reveals, finished with two coats of render flush with existing walls, block up internally with 100mm blockwork finished with 2 coats of plaster flush with existing walls, include for new dpc’s and stainless steel wall ties, make good any cavity wall insulation, and remove waste and debris

102773 R OPENING:BUILD UP EXTERNAL IN FACINGS SM 158.63 Opening:Build up existing opening for door or window, remove door

or window frame, tiled cill, concrete cill, internal lintol, flat brick on edge arch over, build up externally in facing bricks to match existing, matching tinted mortar and pointed as existing, allow for cutting, toothing and bonding into existing reveals, block up internally with 100mm blockwork finished with 2 coats of plaster flush with existing walls, include for new dpc’s and stainless steel wall ties, make good any cavity wall insulation, and remove waste and debris

Page 69: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

35 Local Space Housing

Lintols and Arches 102901 R LINTEL:RENEW PCC LINTEL LM 97.63 Lintel:Cut out and remove existing lintol from brick wall, prepare to

receive new including all necessary propping and temporary supports, and supply and fix 100x150mm precast concrete lintel reinforced with 2 No. 16mm diameter bars, bed ends in cement lime mortar (1:1:6), renew dpc and make good brickwork, plasterwork and sealant and or cement fillets and and remove waste and debris.

102905 R LINTEL:RENEW WITH CATNIC NE 2.5M LONG NO 208.90 Lintel:Cut out and remove existing lintol from brick wall, prepare to

receive new including all necessary propping and temporary supports, and supply and fix steel Catnic type lintel ne 2.50m long including bedding in mortar, fit cavity tray dpc and make good brickwork/ blockwork, plasterwork, sealant and or cement fillets and and remove waste and debris.

102907 R ARCH:RENEW BRICK ON EDGE LM 59.88 Arch:Renew brick on edge arch in facing bricks, bedded and

pointed in cement lime mortar to match existing, provide all necessary temporary supports and make good/rebuild as necessary brickwork over arch and renew sealant and or cement mortar fillets and and remove waste and debris.

102911 R ARCH:RENEW BRICK ON END LM 64.26 Arch:Renew brick on end arch in facing bricks, bedded and pointed

in cement lime mortar to match existing, provide all necessary temporary supports and make good/rebuild as necessary brickwork over arch and renew sealant and or cement mortar fillets and and remove waste and debris.

Cills and Thresholds 103101 R CILL:RENEW SINGLE QUARRY TILE NO 11.68 Cill:Renew any quarry tile to cill, bed in mortar and point to match

existing including clean off and all cutting and all making good and remove waste and debris.

103103 R CILL:RENEW WITH 2 COURSE QUARRY TILES LM 49.55 Cill:Renew any cill with quarry tile cill two courses high including

carefully cutting out existing cill and prepare surfaces to receive new tiles, insert new damp proof membrane and bed new tiles in cement mortar to gradient as required, make good all brick/blockwork and all finishes disturbed and renew sealant and or cement fillets and remove waste and debris.

103105 R CILL:MAKE GOOD DAMAGED CONCRETE CILL NO 53.21 Cill:Hack off defective area of concrete cill, clean and treat any

exposed reinforcement, drill into cill and insert 6mm diameter reinforcing bars at 150mm centres, apply bonding agent and reform cill with fine concrete to match existing profiles including all necessary formwork, make good to structure and all finishes and fillets and remove waste and debris.

Page 70: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

36 Local Space Housing

103107 R CILL:RENEW PCC CILL LM 49.81 Cill:Cut out and remove existing cill from brick wall, prepare and lay

precast concrete splay rebated twice grooved, finished fair cill with stooled ends reinforced with 2 No. 6mm diameter bars bedded in cement lime mortar (1:1:6), renew dpc and make good brickwork, plasterwork, sealant and or cement fillets and remove waste and debris.

103109 R CILL:REBED INDIVIDUAL BRICK TO CILL NO 4.10 Cill:Rebed individual brick to any type of brick cill including take off,

clean and rebed and point in mortar to match existing and make good to all finishes and fillets, and remove waste and debris.

103111 R CILL:REBED BRICK ON EDGE CILL LM 29.41 Cill:Rebed brick on edge cill to one brick wall including take off,

clean and rebed and point in mortar to match existing and make good to all finishes and fillets, and remove waste and debris.

103113 R CILL:RENEW BRICK ON EDGE CILL LM 43.24 Cill:Renew brick on edge cill to one brick wall including take out

existing bricks, prepare and insert new dpc, supply and lay new facing bricks to match existing bedded and pointed in cement lime mortar (1:1:6) and make good all brickwork, plasterwork, sealant and or cement fillets, and remove waste and debris.

103115 R CILL:REBED BRICK ON END CILL LM 27.22 Cill:Rebed brick on end soldier course to half brick wall including

take off, clean and rebed and point in mortar to match existing and make good to all finishes and fillets, and remove waste and debris.

103117 R CILL:RENEW BRICK ON END CILL LM 41.05 Cill:Renew brick on end soldier course to half brick wall including

take out existing bricks, prepare and insert new dpc, supply and lay new facing bricks to match existing bedded and pointed in cement lime mortar (1:1:6) and make good all brickwork, plasterwork, sealant and or cement fillets, and remove waste and debris.

103119 R THRESHOLD:RENEW WITH PCC NO 44.11 Threshold:Break out existing threshold and renew with precast

concrete threshold size ne 80x140mm with water bar, finished fair on exposed faces and reinforced for handling as necessary and bedded and jointed in cement lime mortar (1:1:6) and remove waste and debris.

103121 R THRESHOLD:RENEW WITH INSITU CONCRETE NO 61.85 Threshold:Break out existing threshold and renew with insitu

concrete (1:2:4), threshold ne 80x140mm with water bar, including fix and strike formwork and finished fair on exposed faces and make good all work disturbed and remove waste and debris.

Copings 103301 R COPING:RENEW ISOLATED BRICK ON EDGE NO 4.57 Coping:Renew isolated brick in brick on edge coping including clean

and prepare wall and brick and bed and point new brick in cement lime mortar (1:1:6) all to match existing and remove waste and debris.

Page 71: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

37 Local Space Housing

103303 R COPING:REBED BRICK ON EDGE COPING LM 29.41 Coping:Take off brick coping to one brick wall, clean mortar from

bricks and top of wall, clear away rubble, and rebed bricks in cement lime mortar (1:1:6) and point to match existing and remove waste and debris.

103305 R COPING:LAY NEW BRICK ON EDGE COPING LM 29.10 Coping:Supply and lay facing bricks in brick on edge coping to one

brick wall in cement lime mortar (1:1:6), and point as the work proceeds.

103307 R COPING:REBED PCC COPING LM 8.36 Coping:Take off precast coping ne 300mm wide, clean mortar from

top of wall and coping, bed and point in cement lime mortar (1:1:6) with bonding agent and remove waste and debris.

103311 R COPING:LAY NEW PCC COPING LM 17.69 Coping:Supply and lay new precast concrete coping ne 300mm

wide in section to match existing, bedded and pointed in cement lime mortar (1:1:6) with bonding agent.

103315 R COPING:RENEW TILE CREASING LM 12.71 Coping:Renew any single tile creasing to wall in conjunction with

coping renewal including clean off, lay, bed and point in cement lime mortar (1:1:6) to match existing and remove waste and debris.

103317 R COPING:RENEW 2 ROW TILE CREASING LM 27.61 Coping:Renew any double tile creasing to wall in conjunction with

coping renewal including clean off, lay, bed and point in cement lime mortar (1:1:6) to match existing and remove waste and debris.

Damp Proof Courses 110001 R DPC:INSTALL NEW CAVITY TRAY DPC LM 47.33 DPC:Cut out three courses of brickwork to external skin, chase

internal skin, supply and lay new polypropylene base cavity tray, relay three courses of brick in cement lime mortar (1:1:6) and treat with waterproof solution and remove waste and debris.

110003 R DPC:INSTALL PROPRIETARY CAVITY TRAY DPC LM 72.93 DPC:Cut out external skin of brick/block/stone/reconstructed stone

wall, chase internal skin, supply and build in proprietary cavity tray, relay brick/block/stone/reconstructed stone in cement lime mortar (1:1:6) including providing any additional facing material and point to match existing, treat with waterproof solution and remove waste and debris.

Anti-Fungicide Treatment 114001 R WALL OR CEILING:APPLY ANTI-FUNGICIDE SM 2.89 Wall or Ceiling:Brush down and apply anti-fungicide solution to

walls and or ceilings and wash off traces of fungus and remove waste and debris.

Page 72: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

38 Local Space Housing

Airbricks and Vents Airbricks 115001 R AIRBRICK:RENEW WITH PVC NO 13.68 Airbrick:Cut out existing airbrick and renew with 225x150mm PVC

ventilator, bed and point in cement lime mortar (1:1:6) and make good any finishes, and remove waste and debris.

115003 R AIRBRICK:INSTALL NEW PVC VENT NO 54.76 Airbrick:Cut or form opening in wall and insert 225x150mm PVC

ventilator, bed and point in cement lime mortar (1:1:6), insert cavity lining and internal vent with flyscreen, make good finishes internally and externally, and remove waste and debris.

115005 R AIRBRICK:RENEW CLAY OR CONCRETE VENT NO 14.85 Airbrick:Cut out existing airbrick and renew with 225x150mm clay/

concrete ventilator, bed and point in cement lime mortar (1:1:6) and make good any finishes, and remove waste and debris.

115007 R AIRBRICK:INSTALL NEW CLAY OR CONCRETE VENT NO 55.78 Airbrick:Cut or form opening in wall and insert 225x150mm clay/

concrete ventilator, bed and point in cement lime mortar (1:1:6), insert cavity lining and internal vent with flyscreen, make good finishes internally and externally, and remove waste and debris.

115009 R AIRBRICK:REBED LOOSE VENT NO 11.10 Vent:Take out loose ventilator or airbrick and rebed and point in

cement lime mortar (1:1:6) to match existing.

Ventilators 115011 R VENTILATOR:RENEW PVC OR ALUMINIUM NO 10.77 Ventilator:Supply and fix 225x150mm ‘Hit and Miss’ PVC or

aluminium ventilator grille fixed to any background including remove any existing ventilator and make good all finishes, and remove waste and debris.

115012 R VENT:INSTALL PROPRIETARY VENT KIT NO 66.78 Vent:Supply and install approx. 125mm diameter proprietary

ventilator kit complete including core drill openings through external/internal cavity walls and install vent kit and sleeving, and make good including all external and internal finishes, and remove waste and debris.

115014 R VENT:INSTALL TUMBLE VENT KIT NO 54.08 Vent:Supply and install approx. 100mm diameter tumble drier vent

kit complete including 3 metre length of 100mm flexible PVC ducting, including cutting openings through external/internal walls, install kit complete and make good all finishes, and remove waste and debris.

Page 73: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

39 Local Space Housing

Chimneys Chimney Stacks 120001 R CHIMNEY:REBUILD 4 COURSE 1 FLUE IT 137.52 Chimney:Take down and rebuild four courses to single flue stack,

clean and store bricks, rebuild with existing bricks in mortar including provision of any extra bricks to match where existing are defective, allow for forming corbel courses and parging flue, refix/renew pot, flue liner, pcc capping, lead flashings and dpc and point/make good applied finishes to match existing, and remove waste and debris.

120003 R CHIMNEY:REBUILD 1 COURSE 1 FLUE IT 17.05 Chimney:Extra to take down and rebuild single flue stack for each

additional course taken down and rebuilt.

120005 R CHIMNEY:REBUILD 4 COURSE 2 FLUE IT 253.19 Chimney:Take down and rebuild four courses to two flue stack,

clean and store bricks, rebuild with existing bricks in mortar including provision of any extra bricks to match where existing are defective, allow for forming corbel courses and parging flue, refix/renew pots, flue liners, pcc capping, lead flashings and dpc and point/make good applied finishes to match existing, and remove waste and debris.

120007 R CHIMNEY:REBUILD 1 COURSE 2 FLUE IT 33.87 Chimney:Extra to take down and rebuild two flue stack for each

additional course taken down and rebuilt.

120009 R CHIMNEY:REBUILD 4 COURSE 4 FLUE IT 430.39 Chimney:Take down and rebuild four courses to four flue stack,

clean and store bricks, rebuild with existing bricks in mortar including provision of any extra bricks to match where existing are defective, allow for forming corbel courses and parging flue, refix/renew pots, flue liners, pcc capping, lead flashings and dpc and point/make good applied finishes to match existing, and remove waste and debris.

120011 R CHIMNEY:REBUILD 1 COURSE 4 FLUE IT 57.32 Chimney:Extra to take down and rebuild four flue stack for each

additional course taken down and rebuilt.

120013 R CHIMNEY:REBUILD 4 COURSE 6 FLUE IT 687.98 Chimney:Take down and rebuild four courses to six flue stack,

clean and store bricks, rebuild with existing bricks in mortar including provision of any extra bricks to match where existing are defective, allow for forming corbel courses and parging flue, refix/renew pots, flue liners, pcc capping, lead flashings and dpc and point/make good applied finishes to match existing, and remove waste and debris.

120015 R CHIMNEY:REBUILD 1 COURSE 6 FLUE IT 77.71 Chimney:Extra to take down and rebuild six flue stack for each

additional course taken down and rebuilt.

Page 74: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

40 Local Space Housing

120017 R CHIMNEY:REBUILD 4 COURSE 8 FLUE IT 905.17 Chimney:Take down and rebuild four courses to eight flue stack,

clean and store bricks, rebuild with existing bricks in mortar including provision of any extra bricks to match where existing are defective, allow for forming corbel courses and parging flue, refix/renew pots, flue liners, pcc capping, lead flashings and dpc and point/make good applied finishes to match existing, and remove waste and debris.

120019 R CHIMNEY:REBUILD 1 COURSE 8 FLUE IT 97.22 Chimney:Extra to take down and rebuild eight flue stack for each

additional course taken down and rebuilt.

120021 R CHIMNEY:DEMOLISH STACK AND MAKE GOOD ROOF IT 303.50 Chimney:Demolish chimney stack including any applied finishes,

liners, concrete slabs, pots and haunchings down to below roof level, make good roof where stack removed including cap flues with concrete cover slab, cut into flues and insert 225x225mm airbricks, extend roof covering including felt, battens and timber as necessary to match existing, and remove waste and debris.

120023 R CHIMNEY:SEAL FLUE IT 66.73 Chimney:Remove pot and seal flue opening to chimney stack with

slates bedded in mortar (1:1:6) cut out and insert air vent in chimney breast, make good all works disturbed and remove waste and debris.

120025 R CHIMNEY:RENEW FACING BRICKS NE 6NO NO 5.01 Chimney:Renew facing brick to chimney stack ne 6 No. cut out

defective brick, lay new facing bricks bedded and pointed in mortar to match existing, make good all works disturbed and remove waste and debris (per brick).

120027 R CHIMNEY:RENEW BRICKS NE 0.50SM NO 91.03 Chimney:Renew facing bricks in chimney stack in area ne 0.50sm,

cut out defective bricks, lay new facing bricks bedded and pointed in mortar to match existing, make good all works disturbed and remove waste and debris.

120029 R CHIMNEY:RAKE OUT AND REPOINT STACK SM 31.12 Chimney:Rake out joints to brickwork to chimney stack, minimum

12mm, and repoint in cement lime mortar (1:1:6) to match existing make good all works disturbed and remove waste and debris.

120031 R CHIMNEY:RENEW TWO COAT RENDER TO STACK SM 46.59 Chimney:Renew any thickness of render to chimney, hack off, rake

out, prepare and apply 18mm thick two coats cement and sand render trowelled smooth including all labours, make good all works disturbed and remove waste and debris.

Flue Sundries 125001 E CHIMNEY:BALL FLUE AND CLEAR OBSTRUCTION IT 34.89 Chimney:Ball chimney flue, clear obstruction and clean up including

all associated work, and remove waste and debris.

125003 E CHIMNEY:BALL FLUE REMOVE COWL IT 45.82 Chimney:Remove cowl, ball chimney flue, clear obstructions and

clean up, refix cowl, including all associated works, and remove waste and debris.

Page 75: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

41 Local Space Housing

125005 E CHIMNEY:CLEAR BLOCKED FLUE IN ROOF IT 107.33 Chimney:Clear blockage from flue in roof area, cut into flue,

remove blockage, rebuild and make good flue and stack and remove waste and debris.

125007 E CHIMNEY:CLEAR BLOCK FLUE IN BREAST IT 124.08 Chimney:Clear blockage from flue in chimney breast, cut hole in

breast and flue, remove blockage, make good to flue, breast and wall finishes and remove waste and debris.

125010 E CHIMNEY:SWEEP FLUE - REGISTERED IT 60.45 Chimney:Sweep flue, including protect carpets, furniture etc., and

remove waste and debris, work to be undertaken by a registered chimney sweep.

125011 E CHIMNEY:SMOKE TEST AND REPORT IT 22.23 Chimney:Smoke test flue including all associated work and written

report to Client Representative.

Chimney Pots, Caps, Cowls Etc. 130003 R CHIMNEY:RENEW POT NE 900MM HIGH NO 151.57 Chimney:Renew existing pot with any new pot ne 900mm high

including clean off, alter existing opening to suit, bed and flaunch in cement mortar (1:3) and remove waste and debris.

130007 R CHIMNEY:RENEW MARCONE NE 990MM NO 137.04 Chimney:Renew existing pot with Marcone Flue terminal ne 990mm

high including clean off, alter existing opening to suit, bed and flaunch in cement mortar (1:3) and remove waste and debris.

130009 U CHIMNEY:REBED POT NO 21.18 Chimney:Remove and refix existing pot including clean off pot and

flaunching, prepare and rebed in mortar (1:3) and make good flaunching and remove waste and debris.

130011 R CHIMNEY:INSTALL COLT COWL NO 53.19 Chimney:Supply and fix new Colt type cowl to chimney pot. 130013 R CHIMNEY:INSTALL AEROCOWL TO POT NO 84.60 Chimney:Supply and fix new 175x150mm diameter Aerocowl to

chimney pot.

130015 R CHIMNEY:450MM VENTED CAP TO POT NO 41.09 Chimney:Supply and fix new terra cotta vented cap 450mm high to

chimney pot.

130017 R CHIMNEY:RENEW GC GAS TERMINAL NO 59.62 Chimney:Supply and fix GC gas terminal including remove old

terminal, clean off bed, alter opening to suit and bed and flaunch terminal in mortar (1:3) and remove waste and debris.

130019 R CHIMNEY:RENEW GALVANISED WIRE BIRDCAGE NO 30.11 Chimney:Renew heavy galvanised wire birdcage to any size

chimney pot including removal of old cage and remove waste and debris.

Page 76: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

42 Local Space Housing

130021 R CHIMNEY:REMOVE AND REFIX TV AERIAL OR DISH NO 17.51 Chimney:Remove and refix TV Aerial or satellite dish to chimney

stack including disconnection and later reconnection and testing (in conjunction with associated chimney works).

Meter Cupboards Gas/Electric Meter Cupboards 135001 R METER CUPBOARD:RENEW OR SUPPLY AND FIX NEW NO 68.31 Meter Cupboard:Renew or fix new approved meter cupboard size

380x825x210mm complete with locking device and all other ironmongery and plug and screw to walls and make good and remove waste and debris.

135003 R METER CUPBOARD:RENEW DOOR NO 33.70 Meter Cupboard:Take off existing, and remove waste and debris

and renew any type of meter cupboard door to external meter cupboard.

395201 U METER CUPBOARD:RENEW DOOR HINGE NO 6.37 Meter Cupboard:Renew hinge to door of any plastic gas or electric

meter cupboard.

395203 U METER CUPBOARD:RENEW 3 PORT LOCK NO 17.29 Meter Cupboard:Renew any three port key type lock to plastic door

of gas or electric meter cupboard.

Fireplaces Fire Surrounds and Hearths 140001 R FIREPLACE:RENEW COMPLETE NO 358.83 Firplace:Take out existing fire surround and hearth complete, clear

recess, alter and build in new firebase, fireback and throat unit, prepare for, supply and build in new tiled fireplace surround size not exceeding 1220x900x100mm with opening size 510x575mm and tile returns 50x50x6mm stainless steel angle around opening, 2 No. stainless steel eyes on either side of opening and 1100x500x50mm tiled hearth with tiled return on three sides bedded in cement mortar, make good finishings and remove waste and debris.

140002 R FIRE:RENEW COMPLETE NO 444.50 Fire:Take out existing fire surround and hearth complete, clear recess,

rebuild opening complete with back base, firebase, fireback and lintel, prepare for, supply and build in new tiled fireplace surround size not exceeding 1220x900x100mm with opening size 510x575mm and tile returns 50x50x6mm stainless steel angle around opening, 2 No. stainless steel eyes on either side of opening and 1100x500x50mm tiled hearth with tiled return on three sides bedded in cement mortar, make good finishings and remove waste and debris.

140003 R FIRE:RENEW SURROUND NO 145.48 Fire:Take out fire surround and clear away, prepare for, supply and

build in new tiled fire place surround size ne 1220x900x100mm with opening size 510x575mm, and tile returns 50x50x6mm stainless steel angle around opening, 2 No. stainless steel eyes on either side of opening, make good all finishings and remove waste and debris.

Page 77: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

43 Local Space Housing

140005 R FIRE:RENEW SURROUND AND HEARTH NO 248.52 Fire:Remove existing and renew tiled fireplace surround and hearth

size ne 1200x900x100mm with opening size 510x575mm complete with shelf, bedded in cement lime mortar (1:1:6) make good finishings and remove waste and debris.

140007 R FIRE:RENEW HEARTH COMPLETE NO 122.06 Fire:Take out tiled hearth, clear away, prepare for, supply and build

in tiled hearth size ne 1220x500x50mm with tiled returns on three sides bedded in cement mortar, make good finishings, and remove waste and debris.

140008 R FIRE:ADAPT FOR GAS NO 150.83 Fire:Remove existing fireplace surround and hearth, backboiler and fire,

blank off pipework, modify opening to gas regulation standard to suit any gas fire and backboiler (installed by others) including extending skirting and make good finishes, size ne 1200x900x 100mm with opening size 510x575mm complete with shelf, bedded in cement lime mortar (1:1:6), make good finishings and remove waste and debris.

140010 R FIRE:REMOVE REFIX FOR BACKBOILER RENEWAL NO 194.19 Fire:Remove existing fireplace surround, and firebricks, in conjunction

with backboiler renewal, (measured separately)and set aside, later refix including renew any damaged firebricks, bedded in cement mortar, and fireclay, make good all works disturbed, and remove waste and debris.

140050 R FIRE:REMOVE FIRE AND BACKBOILER IT 187.56 Fire:Remove fire surround and hearth and burning appliance, drain down

and removal of back boiler unit, flow and return pipes back to cylinder, thoroughly sweep flue, seal opening and 100mm thick brick or block work and insert 225 x 150 mm permanently fixed plaster louvre vent, prepare walls and render and set to match existing. make good walls and ceiling surfaces to match existing, cut back as required and screed hearth base level with floor, providing skirting to match existing, provide and fit a terracotta pepper pot to chimney and remove waste and debris.

140014 R FIRE:RENEW FIRECHEEK IT 14.69 Fire:Take out and renew single fire-cheek including any cutting out and

rebuilding of brickwork and point with fire cement, clean off and remove waste and debris.

140032 R FIRE:RENEW FIRE BASE NO 46.41 Fire:Take out and renew fire base to open fire, bed and point in fire

cement and remove waste and debris.

140036 R FIRE;RENEW BOTTOM BARS NO 34.87 Fire Take out and renew any bottom bars to all night burner set, and

remove waste and debris.

140038 R FIRE:RENEW FIRE BRICKS IT 65.55 Fire:Renew firebricks to any type of fire, cut out existing and bed new

firebricks in cement mortar and point with fire cement, and remove waste and debris.

140043 R FIRE:REFLAUNCH FLUE IT 29.50 Fire:Clean out mortar from throat of flue and and remove waste and

debris, and reflaunch with fire cement mortar.

Page 78: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

44 Local Space Housing

140045 R FIRE:REPAIR CRACKS TO FIREBRICK IT 15.58 Fire:Rake out cracks in firebrick back, point in flush with fire cement

mortar.

140047 R FIRE:REBED TILED HEARTH IT 30.11 Fire:Take up existing tiled hearth, clean off old bed and rebed in cement

mortar (1:3).

140049 R FIRE:REFIX FIRE SURROUND IT 42.29 Fire:Take off existing tiled fire surround and refix to wall by plugging and

screwing, make good plasterwork disturbed.

140051 R FIRE:RENEW FIREBACK IT 79.13 Fire:Remove existing defective fireback and fix new fireback, ease and

clean damper and remove waste and debris.

193.10 140053 R FIRE:RENEW ADJUSTABLE THROAT UNIT IT Fire:Remove existing and fix new adjustable throat restrictor unit and

remove waste and debris.

14.33 140055 R FIRE:RENEW ASBESTOS TYPE ROPE IT Fire:Remove defective asbestos type rope to any type of joint, refix new

asbestos type rope, wedge and point in and remove waste and debris.

9.04 140057 R FIRE:REFIX ASBESTOS TYPE ROPE IT Fire:Wedge and point existing asbestos type rope to any joint. Fire Openings etc 113.63 140009 R FIRE:REMOVE FIRE AND SEAL OPENING IT Fire:Take out fire, surround and hearth, seal opening with

brickwork or blockwork in mortar (1:1:6), cut tooth and bond to existing brickwork form opening 150x75mm for and fix plaster vent with flyscreen, render and set wall, including make good floor and skirting, and seal chimney cap and remove waste and debris.

44.34 140011 R FIRE:RENEW LINTOL TO OPEN FIRE IT Fire:Take out lintol and clear away, prepare for, supply and fix new

bevelled concrete fireplace lintol and point with fire cement and remove waste and debris.

8.92 140013 R FIRE:REPOINT TILES WITH FIRE CEMENT IT Fire:Clean out and repoint joints of fireclay tiles with fire cement

and remove waste and debris.

25.01 140015 R FIRE:RENEW FIRECHEEKS IT Fire:Take out and renew pair of fire-cheeks including any cutting

out and rebuilding of brickwork and point with fire cement and remove waste and debris.

36.34 140017 R FIRE:RENEW FIRECHEEKS AND ASH PIT IT Fire:Take out and renew pair of fire-cheeks and ash pit including

any cutting out and rebuilding of brickwork and point with fire cement and remove waste and debris.

6.78 140019 R FIRE:CLEAN AND RESET DAMPER NO Fire:Clean throating and reset damper plate to open fireplace.

Page 79: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

45 Local Space Housing

140021 R FIRE:RENEW STANDARD SIZE CANOPY NO 26.74 Fire:Take off and renew standard size canopy to any fire and make

good finishings and seal joints and remove waste and debris.

140025 R FIRE:RENEW SINGLE GLAZED TILE NO 4.89 Fire:Hack off tile, prepare and renew individual glazed tile to

surround or hearth to match existing, fixed with adhesive, grout in, clean off and and remove waste and debris.

140027 R FIRE:RENEW GLAZED TILES SM 139.57 Fire:Hack off tiles, prepare and renew glazed tiles to surround or

hearth to match existing, fixed with an approved adhesive, grout in, clean off and and remove waste and debris.

Fire Parts 140023 R FIRE:RENEW ALL NIGHT BURNER GRATE IT 36.52 Fire:Take out and renew standard all night burner grate and

remove waste and debris.

708001 R FIRE:RENEW ALL NIGHT BURNER NO 251.89 Fire:Renew with BCC approved all night burner, seal joints with

asbestos free rope and fire cement complete, bedded in fireproof cement and remove waste and debris.

140028 R FIRE:OVERHAUL DEFECTIVE SOLID FUEL APPLIANCE NO 38.98 Fire:Take out, clean, reset and resecure all night burner bedded in

fireproof cement, clean throating and reset damper to open fireplace, check operation of fire and remove waste and debris.

140029 R FIRE:RENEW FIRE BASKET NO 26.10 Fire:Take out and renew fire basket to open fire and remove waste

and debris.

140031 R FIRE:RENEW FIRE FRET NO 32.13 Fire:Take out and renew fire fret to open fire and remove waste

and debris.

140033 R FIRE:SUPPLY SET OF TOOLS NO 18.56 Fire:Supply and place in position operating tools for all night

burner.

140035 R FIRE:RENEW BOTTOM GRATE NO 27.24 Fire:Take out and renew bottom grate to all night burner and

remove waste and debris.

140037 R FIRE:REFIX ALL NIGHT BURNER NO 28.23 Fire:Take out, clean, reset and resecure all night burner bedded in

fireproof cement and and remove waste and debris.

140039 R FIRE:RENEW GLASS IT 52.34 Fire:Take out and renew glass strip to door of closed room heater,

clean out rebates, and remove waste and debris and make good.

140041 R FIRE:RENEW GLASS SET IT 71.09 Fire:Take out and renew set of glass strips to door of closed room

heater, clean out rebates, remove waste and debris and make good.

Page 80: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

46 Local Space Housing

Cookers (Rayburn or Similar) 145001 R COOKER:REMOVE SOLID FUEL COOKER COMPLETE IT 354.27 Cooker:Drain down system, disconnect cooker, boiler and flue and

remove, build up recess with concrete brickwork in cement lime mortar (1:1:6) including supply and build in 750x350x403mm precast concrete throating block with 200mm diameter flue hole and 750x95x150mm precast concrete lintel, make good works disturbed and remove waste and debris.

Page 81: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

47 Local Space Housing

MASONRY Natural Stone 102201 R STONE:REBUILD WALL NE 300MM NS IRREGULAR COURSES SM 219.10 Stone:Rebuild stone wall ne 300mm thick, take down and clean off,

set aside and rebuild irregular coursed natural stone wall including providing additional stone to match as necessary bed, joint and point to match existing in lime mortar (1:3) including copings and other features, and remove waste and debris.

102203 R STONE:REBUILD WALL OVER 300MM NS IRREGULAR SM 275.38 Stone:Rebuild stone wall over 300mm thick take down and clean

off, set aside and rebuild irregular coursed natural stone wall including providing additional stone to match as necessary bed, joint and point to match existing in lime mortar (1:3) including copings and other features, and remove waste and debris.

102205 R STONE:REBUILD WALL NE 300MM NS REGULAR COURSES SM 260.68 Stone:Rebuild stone wall ne 300mm thick take down and clean off,

set aside and rebuild regular coursed natural stone wall including providing additional stone to match as necessary bed, joint and point to match existing in lime mortar (1:3) including copings and other features, and remove waste and debris.

102207 R STONE:REBUILD WALL OVER 300MM NS REGULAR COURSES SM 327.90 Stone:Rebuild stone wall over 300mm thick take down and clean

off, set aside and rebuild regular coursed natural stone wall including providing additional stone to match as necessary bed, joint and point to match existing in lime mortar (1:3) including copings and other features, and remove waste and debris.

Reconstructed Stone 102211 R STONE:REBUILD WALL NE 300MM RS IRREGULAR COURSES SM 164.69 Stone:Rebuild stone wall ne 300mm thick take down and clean off,

set aside and rebuild irregular coursed reconstructed stone wall including providing additional stone to match as necessary bed, joint and point to match existing in gauged mortar (1:1:6) including copings and other features, and remove waste and debris.

102213 R STONE:REBUILD WALL OVER 300MM RS IRREGULAR SM 209.47 Stone:Rebuild stone wall over 300mm thick t ake down and clean

off, set aside and rebuild irregular coursed reconstructed stone wall including providing additional stone to match as necessary bed, joint and point to match existing in gauged mortar (1:1:6) including copings and other features, and remove waste and debris.

102215 R STONE:REBUILD WALL NE 300MM RS REGULAR COURSES SM 193.13 Stone:Rebuild stone wall ne 300mm thick take down and clean off,

set aside and rebuild regular coursed reconstructed stone wall including providing additional stone to match as necessary bed, joint and point to match existing in gauged mortar (1:1:6) including copings and other features, and remove waste and debris.

Page 82: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

48 Local Space Housing

102217 R STONE:REBUILD WALL OVER 300MM RS REGULAR COURSES SM 244.48 Stone:Rebuild stone wall over 300mm thick take down and clean

off, set aside and rebuild regular coursed reconstructed stone wall including providing additional stone to match as necessary bed, joint and point to match existing in gauged mortar (1:1:6) including copings and other features, and remove waste and debris.

102219 R STONE:REBUILD WALL CAVITY SKIN RS REGULAR COURSES SM 178.95 Stone:Rebuild stone outer skin of cavity wall take down and clean

off, set aside and rebuild 100mm regular coursed reconstructed stone outer skin including providing additional stone to match as necessary bed, joint and point to match existing in gauged mortar (1:1:6) including stainless steel wall ties, damp proof courses, seal cavity around openings, build in lintols, bonding to existing, and remove waste and debris.

102221 R STONE:REBUILD WALL CAVITY SKIN RS IRREGULAR SM 146.60 Stone:Rebuild stone outer skin of cavity wall take down and clean

off, set aside and rebuild 100mm irregular coursed reconstructed stone outer skin including providing additional stone to match as necessary bed, joint and point to match existing in gauged mortar (1:1:6) including stainless steel wall ties, damp proof courses, seal cavity around openings, build in lintols, bonding to existing, and remove waste and debris.

102223 R WALL:RAKE OUT AND REPOINT STONEWORK SM 27.74 Wall:Rake out existing joints of stonework minimum 20mm deep

and repoint in cement or lime mortar to match existing and remove waste and debris.

102225 R WALL:RAKE OUT REPOINT AND RESET STONEWORK SM 108.07 Wall:Rake out existing joints of stonework minimum 20mm deep

allow for dubbing out and resetting stonework including provision of any new matching stonework and repoint in cement or lime mortar to match existing and remove waste and debris.

Stone Repairs 146101 R SURFACES:REPAIR CRACKS STONEWORK NE 5MM SM 129.61 Surfaces:Prepare, clean off all dust and debris, fill in or resurface

cracks or spalled surfaces of stone with epoxy mortar in general surfaces of stone exceeding 300mm wide, repair ne 5mm deep and remove waste and debris.

146103 R LINTELS/CILLS:REPAIR CRACKS STONEWORK NE 5MM LM 26.80 Lintels/Cills:Prepare, clean off all dust and debris, fill in or resurface

cracks or spalled surfaces of stone with epoxy mortar in surfaces of lintels, and the like, ne 300mm girth, repair ne 5mm deep and remove waste and debris.

146107 R SURFACES:REPAIR CRACKS STONEWORK NE 10MM SM 232.96 Surfaces:Prepare, clean off all dust and debris, fill in or resurface

cracks or spalled surfaces of stone with epoxy mortar in general surfaces of stone exceeding 300mm wide, repair over 5 and ne 10mm deep and remove waste and debris.

Page 83: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

49 Local Space Housing

146109 R LINTELS/CILLS:REPAIR CRACKS STONEWORK NE 10MM LM 47.03 Lintels/Cills:Prepare, clean off all dust and debris, fill in or resurface

cracks or spalled surfaces of stone with epoxy mortar in surfaces of lintels, and the like, ne 300mm girth, repair over 5 and ne 10mm deep and remove waste and debris.

146113 R SURFACES:REPAIR CRACKS STONEWORK NE 15MM SM 336.31 Surfaces:Prepare, clean off all dust and debris, fill in or resurface

cracks or spalled surfaces of stone with epoxy mortar in general surfaces of stone exceeding 300mm wide, repair over 10 and ne 15mm deep and remove waste and debris.

146115 R LINTELS/CILLS:REPAIR CRACKS STONEWORK NE 15MM LM 67.26 Lintels/Cills:Prepare, clean off all dust and debris, fill in or resurface

cracks or spalled surfaces of stone with epoxy mortar in surfaces of lintels, and the like, ne 300mm girth, repair over 10 and ne 15mm deep and remove waste and debris.

Page 84: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

50 Local Space Housing

ROOFING Clay/Concrete Roof Tiling Concrete Interlocking Roof Tiles to Match Existing 201101 R ROOF TILE:RENEW CONCRETE INTERLOCKING NE 5 NO IT 17.70 Roof Tile:Renew any size and type of concrete interlocking roof tile

(in groups ne 5 No.) including remove defective tile and fix new, replace felt and battens if necessary and remove waste and debris.

201103 R ROOF TILE:RENEW CONCRETE INTERLOCKING OVER 5 NO SM 50.24 Roof Tile:Renew any size and type of concrete interlocking roof tile

(in groups over 5 No.) and remove waste and debris.

201107 U ROOF TILE:REMOVE AND REFIX INTERLOCKING NE 5 NO IT 13.92 Roof Tile:Remove and refix loose concrete interlocking tiles (in

groups ne 5 No.).

201109 U ROOF TILE:REMOVE REFIX INTERLOCKING OVER 5 NO SM 34.83 Roof Tile:Remove and refix loose concrete interlocking tile (in

groups over 5 No.).

201113 R ROOF TILE:OVERHAUL INTERLOCKING ROOF COMPLETE SM 35.50 Roof Tile:Overhaul interlocking tile roof, refix loose tiles, renew

broken or missing tiles to match existing, redress, rewedge and repoint all flashings, aprons, chimney gutters etc, cut out and make good cement weather fillets, repoint in cement mortar (1:3) to all hips, ridges and verges, make good, and remove waste and debris.

201150 R ROOF COVERING:EXTRA TO RENEW FELT AND BATTENS SM 24.77 Roof Covering:Extra over any renewal or refixing of roof tiles or

slates for renew roofing felt and battens.

Concrete or Clay Plain Tiles to Match Existing 201301 R ROOF TILE:RENEW PLAIN CONCRETE OR CLAY NE 10 NO IT 26.29 Roof Tile:Renew any plain concrete or clay roof tile (in groups ne

10 No.) including remove defective tile and fix new, replace felt and battens if necessary and remove waste and debris..

201303 R ROOF TILE:RENEW PLAIN CONCRETE OR CLAY OVER 10 NO SM 137.99 Roof Tile:Renew any plain concrete or clay roof tiles (in groups over

10 No.) and remove waste and debris..

201307 U ROOF TILE:REMOVE AND REFIX PLAIN NE 10 NO IT 18.22 Roof Tile:Remove and refix loose plain concrete or clay roof tile (in

groups ne 10 No.).

201309 U ROOF TILE:REMOVE AND REFIX PLAIN OVER 10 NO SM 76.37 Roof Tile:Remove and refix loose plain concrete or clay roof tiles (in

groups over 10 No.).

Page 85: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

51 Local Space Housing

201313 R ROOF TILE:OVERHAUL PLAIN TILE ROOF COMPLETE SM 35.50 Roof Tile:Overhaul concrete or clay plain tile roof, refix loose tiles,

renew broken or missing tiles to match existing, redress, rewedge and repoint all flashings, aprons, chimney gutters etc, cut out and make good cement weather fillets, repoint in cement mortar (1:3) to all hips, ridges and verges, make good, and remove waste and debris.

Concrete or Clay Verges 201501 R VERGE:RAKE OUT AND REPOINT IN MORTAR LM 31.90 Verge:Rake out and repoint verge tiles with coloured mortar (1:3)

to match existing and remove waste and debris..

201503 R VERGE:RENEW TILE VERGE LM 41.17 Verge:Renew verge and undercloak to concrete or clay tiles bedded

and pointed in coloured mortar (1:3) including all cutting of tiles and refix or renew stainless steel verge clips and remove waste and debris..

201505 U VERGE:REMOVE AND REFIX TILE LM 35.49 Verge:Remove and refix loose verge tiles bedded and pointed in

coloured mortar (1:3) including refix or renew stainless steel verge clips as necessary.

Concrete or Clay Bedded Ridges, Hips and Valley Tiles 201703 R RIDGE:RENEW BEDDED TILE LM 78.13 Ridge:Renew half round or angled ridge or hip tiles edge bedded

onto roofing tiles with solid bedding at butt joints in coloured mortar (1:3) and remove waste and debris..

201711 R RIDGE:RENEW MONO-PITCH TILES LM 128.39 Ridge:Renew angled monopitch ridge or hip tiles edge bedded onto

roofing tiles and with solid bedding at butt joints and mechanically fixed through tile to timber battens and remove waste and debris.

201715 U RIDGE:REMOVE AND REFIX TILES LM 63.05 Ridge:Remove and refix any loose ridge or hip tiles edge bedded

onto roof tiles and with solid bedding at butt joints in coloured mortar (1:3) and mechanically fixed where necessary.

201717 R RIDGE:RAKE OUT AND REPOINT TILES LM 48.61 Ridge:Rake out and repoint ridge, hip or valley tiles with coloured

mortar (1:3).

201719 R RIDGE:RENEW ANY TYPE GAS FLUE TERMINAL TILE NO 173.41 Ridge:Renew any type of gas flue ridge terminal, remove existing,

fix new with edges bedded onto roof tiles and with solid bedding at butt joint in coloured mortar (1:3) and remove waste and debris.

201725 R HIP:RENEW BONNET HIP TILES LM 173.32 Hip:Renew bonnet hip tile nailed to hip rafters with 65mm

aluminium alloy nails and with mortar bedding (1:3) under each bonnet tile, struck off smoothly at lower edges of hip tile and remove waste and debris.

201727 R HIP:RENEW GALVANISED HIP IRON NO 23.43 Hip:Renew galvanised hip iron including remove, rebed and repoint

isolated hip tile.

Page 86: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

52 Local Space Housing

201731 R VALLEY:RENEW VALLEY TILES LM 121.51 Valley:Renew any type of valley tile including remove existing tile,

lay new tile to bond with existing roof tiles including take up and relay adjacent tiles as necessary and remove waste and debris..

201735 R VALLEY:RENEW TROUGH VALLEY TILES LM 174.99 Valley:Renew any type of trough valley tile including remove

existing tile, lay new tile, renew any defective battens, remove and refix tiles, felt etc., to either sides of valley and remake mortar bedding and remove waste and debris.

Dry Verge, Ridge and Hip Tiles 209001 R VERGE:RENEW DRY OR CLOAKED VERGE COMPLETE LM 42.95 Verge:Renew dry or cloaked verge complete including remove tiles

as necessary, remove existing and fix new dry verge including end stops, jointing pieces, ridge end units, refix tiles and make good and remove waste and debris.

209003 R VERGE:REFIX DRY OR CLOAKED VERGE COMPLETE LM 21.49 Verge:Refix dry or cloaked verge complete including remove tiles as

necessary, remove existing and refix dry verge including end stops, jointing pieces, ridge end units, refix tiles and make good.

209005 R VERGE:RENEW OR REFIX DRY VERGE RIDGE OR END STOP NO 9.32 Verge:Renew or refix dry verge, ridge end or end stop. 209015 R RIDGE:RENEW DRY RIDGE TILES LM 61.24 Ridge:Renew any type of dry ridge tile including remove existing,

renew filler units to both sides of ridge and fix new dry ridge tile with aluminium alloy nails with integral washers to ridge board including ridge to ridge sealing pieces and blocked end ridge tiles where necessary and remove waste and debris.

209017 R RIDGE:RENEW DRY RIDGE GAS FLUE TERMINAL NO 155.04 Ridge:Renew Gas flue ridge terminal to any dry ridge system

including remove existing and fix new with stainless steel nails with neoprene washers to ridge including renew profile filler units and remove waste and debris.

Roof Ventilation 211001 R VENT:RENEW VENT ROOF TILE UNIT NO 54.75 Vent:Renew or supply and fix new ventilation roof tile unit complete

to match existing roof tiles or slates including remove, refix adjacent tiles as necessary.

211003 R RIDGE:RENEW WITH HALF ROUND OR ANGLE VENT TILE NO 106.06 Ridge:Remove half round or angle ridge tile and renew with

ventilator ridge tile, edge bedded onto roof tiles and with solid bedding at butt joints in coloured mortar (1:3) and remove waste and debris.

211009 R RIDGE:RENEW DRY VENT TILES LM 97.57 Ridge:Renew any type of dry vent ridge tile including remove

existing, renew filler units/air flow control units to both sides of ridge and fix new dry vent ridge tile with stainless steel nails with integral washers to ridge board including ridge to ridge sealing pieces and blocked end ridge tiles where necessary and remove waste and debris.

Page 87: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

53 Local Space Housing

211011 R VENT:RENEW EAVES VENTILATORS LM 37.65 Vent:Renew or supply and fix new eaves ventilators complete

including remove and refix tiles and underlay as necessary, all trays, skirts, eaves filler units, aprons, fascias, grills and the like and fix in accordance with manufacturers instructions and remove waste and debris.

Slate Roofing Fibre Cement Slating 203101 R SLATE:RENEW FIBRE CEMENT NE 5 NO IT 30.97 Slate:Renew fibre cement slate to roof including take out defective

slate and fix new with copper nails and disc rivet including renew defective battens and felt as necessary and remove waste and debris. (in group ne 5 No).

203103 R SLATE:RENEW FIBRE CEMENT OVER 5 NO SM 64.28 Slate:Renew fibre cement slates to roof including remove existing

and fix new with copper nails and disc rivet and remove waste and debris. (in group over 5 No.).

203107 U SLATE:REFIX FIBRE CEMENT NE 5 NO IT 24.45 Slate:Remove and refix loose slate including fixing with new copper

nails and disc rivet as necessary (in group ne 5 No.).

203109 U SLATE:REFIX FIBRE CEMENT OVER 5 NO SM 42.12 Slate:Remove and refix loose slates including fixing with copper

nails and disc rivet (in group over 5 No.).

Natural Slating 203301 R SLATE:RENEW NATURAL SLATE NE 5 NO IT 48.73 Slate:Renew any size natural slate to roof fixed with clips or copper

nails including renewing defective felt and battens as necessary and and remove waste and debris. (in group ne 5 No.).

203303 R SLATE:RENEW NATURAL SLATES OVER 5 NO. SM 124.66 Slate:Renew any size natural slates to roof fixed with clips or

copper nails and and remove waste and debris. (in group over 5 No.).

203307 U SLATE:REFIX NATURAL SLATES NE 5 NO IT 24.38 Slate:Remove and refix any size loose natural slate fixed with clips

or copper nails including renewing defective roofing felt and battens as necessary (in group ne 5 No.).

203309 U SLATE:REFIX NATURAL SLATES OVER 5 NO SM 42.12 Slate:Remove and refix any size loose natural slates fixed with clips

or copper nails (in group over 5 No.).

Fibre Cement Slating - Ridge, Verge and Hips Tiles 203503 R RIDGE:RENEW HALF ROUND OR ROLL TOP TILE TO SLATING LM 71.04 Ridge:Renew half round or roll top ridge or hip tile fixed with

galvanised steel clips and roofing screws with plastic washers including bedding in mastic as per manufacturers instructions and remove waste and debris.

Page 88: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

54 Local Space Housing

203511 R RIDGE:RENEW MONO OR DUO-PITCH TILE TO SLATING LM 126.71 Ridge:Renew mono or duo-pitch ridge or hip tile fixed with roofing

screws with plastic washers including bedding in mastic as per manufacturers instructions and remove waste and debris.

203517 R RIDGE:RENEW GAS VENTILATION TO SLATING NO 119.07 Ridge:Renew duo-pitch gas ventilation ridge, fixed with roofing

screws with plastic washers including bedding in mastic as per manufacturers instructions and remove waste and debris.

203519 R VERGE:RAKE OUT AND REPOINT IN MORTAR TO SLATING LM 31.90 Verge:Rake out and repoint verge tiles to slate roof with coloured

mortar (1:3) to match existing and remove waste and debris.

Vertical Coverings Vertical Tile Hanging 205001 R TILE:RENEW HANGING TILE NE 10 NO IT 26.36 Tile:Renew any plain concrete or clay hanging tile (in group ne 10

No.) including remove defective tile and fix new, replace felt and battens if necessary and remove waste and debris.

205003 R TILE:RENEW HANGING TILES OVER 10 NO SM 121.55 Tile:Renew any plain concrete or clay hanging tiles (in group over

10 No.) and remove waste and debris.

205006 R VERTICAL COVERING:EXTRA TO RENEW FELT AND BATTENS SM 24.77 Vertical Covering:Extra over any renewal or refixing of roof tiles

or slates for renew roofing felt and battens.

205007 U TILE:REFIX HANGING NE 10 NO IT 18.15 Tile:Remove and refix loose plain concrete or clay hanging tiles (in

group ne 10 No. ).

205009 U TILE:REFIX HANGING OVER 10 NO SM 60.30 Tile:Remove and refix loose plain concrete or clay hanging tiles (in

group over 10 No.).

205013 R TILE:RENEW FEATURE TILE HANGING NO 16.50 Tile:Renew any pattern or feature tile to tile hanging including

remove defective tile and fix new, replace felt and battens if necessary and remove waste and debris.

205015 R TILE:RENEW ANGLE HANGING TILE LM 99.58 Tile:Renew angle tile to tile hanging including remove tiles as

necessary for access, remove defective tile and fix new and reinstate tile hanging, renew felt and battens as necessary and remove waste and debris.

Vertical Fibre Cement Slating 207001 R SLATE:RENEW HANGING SLATE NE 5 NO IT 30.97 Slate:Renew fibre cement hanging slate including take out defective

slate and fix new with copper nails, disc rivet or clips including renew defective battens and felt as necessary and remove waste and debris. (in group ne 5 No.).

Page 89: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

55 Local Space Housing

207003 R SLATE:RENEW HANGING SLATES OVER 5 NO SM 64.28 Slate:Renew fibre cement hanging slates including remove existing

and fix new with copper nails and disc rivet or clips and remove waste and debris. (in group over 5 No.).

207007 U SLATE:REFIX HANGING SLATE NE 5 NO IT 24.45 Slate:Remove and refix loose hanging slate including fixing with

new copper nails and disc rivet or clips, renew defective felt and battens as necessary (in group ne 5 No.).

207009 U SLATE:REFIX HANGING SLATE OVER 5 NO SM 42.12 Slate:Remove and refix loose hanging slates including fixing with

copper nails and disc rivet or clips (in group over 5 No).

Sheet Roofing Sheet Roof Coverings 213001 R SHEETING:RENEW GALVANISED CORRUGATED IRON SM 40.40 Sheeting:Renew 24 gauge galvanised corrugated iron sheeting

fixed with hook bolts or drive screws complete with caps and washers and remove waste and debris..

213003 R SHEETING:RENEW CORRUGATED REINFORCED CEMENT SM 37.20 Sheeting:Renew corrugated reinforced asbestos free cement

sheeting fixed with hook bolts or drive screws complete with caps and washers and remove waste and debris..

213005 R SHEETING:RENEW CLEAR PLASTIC SM 28.57 Sheeting:Renew clear plastic corrugated sheeting fixed with hook

bolts or drive screws complete with caps and washers and remove waste and debris..

213007 R SHEETING:RENEW COLOURED PLASTIC SM 31.86 Sheeting:Renew coloured plastic corrugated sheeting fixed with

hook bolts or drive screws complete with caps and washers and remove waste and debris..

213009 R SHEETING:RENEW TRANSLUCENT SM 51.36 Sheeting:Renew corrugated fire resisting glass fibre reinforced

translucent sheeting fixed with hook bolts or drive screws complete with caps and washers and remove waste and debris.

213011 R SHEETING:RENEW PVC COLOUR COATED SM 46.03 Sheeting:Renew PVC colour coated both sides galvanised steel

profiled sheeting 0.70mm thick fixed with hook bolts and washers and remove waste and debris.

213013 R SHEETING:RENEW EAVES FILLER PCE LM 23.88 Sheeting:Renew eaves filler piece to corrugated roof sheeting and

remove waste and debris..

213015 R SHEETING:RENEW TWO PIECE RIDGE LM 36.67 Sheeting:Renew two piece ridge to corrugated roof sheeting and

remove waste and debris.

Page 90: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

56 Local Space Housing

Remedial Works Liquid Applied Waterproof Roof Covering 215001 R ROOF:SWEEP AND APPLY WP COMPOUND SM 23.05 Roof:Sweep off and apply two coats of waterproofing compound

and apply sand dressing between coats, and remove waste and debris..

215003 U ROOF:SEALING COMPOUND TO CRACKS LM 5.88 Roofing:Apply sealing compound to cracks to roof or leadwork. 215005 R ROOF:SWEEP AND APPLY BITUMEN SM 22.52 Roofing:Brush off loose chippings and clean down roof and apply

three coats of bitumen compound, and remove waste and debris.

215007 R ROOF:SWEEP AND APPLY STONE CHIPPINGS SM 12.13 Roofing:Brush off loose chippings from roof and supply and lay

limestone chippings bonded with hot bitumen compound, and remove waste and debris..

215009 R ROOF:PREPARE AND PATCH NE 2.0SM IT 48.82 Roofing:Prepare and apply two coats of approved liquid applied

roof coating to roofing felt, in patches ne 2.00sm and remove waste and debris.

215011 R ROOF:PREPARE AND PATCH OVER 2.0SM SM 29.69 Roofing:Prepare and apply two coats of approved liquid applied

roof coating to roofing felt, in areas over 2.00sm and remove waste and debris..

215013 R GUTTER:APPLY 2 COATS WATERPROOF TO FINLOCK LM 20.24 Gutter:Clean out gutter, rake out and apply sealant to joints and

prepare and apply two coats of proprietary waterproof sealing compound to inside surfaces of Finlock gutter and remove waste and debris.

Inspections 221001 U CLIENT INSPECTION:PROVIDE AND ERECT LADDER IT 41.54 Client Inspection:Provide and erect ladder for inspection in

conjunction with Client Representative to eaves level of roof to property ne 2 storey and remove on completion, and remove waste and debris.

221003 U CLIENT INSPECTION:REMOVE ALL DEBRIS ETC SM 2.77 Client Inspection:Remove all debris, plant, moss etc., from roof to

allow inspection for leaks and remove waste and debris.

Temporary Repairs 223001 U ROOF:TEMPORARY REPAIR SLATE OR TILE ROOF IT 22.54 Roof:Carry out temporary repairs to any type of slate/tiled area of

roof as required to ensure area is weatherproof, provide report to Client Representative.

223003 U ROOF:TEMPORARY REPAIR FLAT ROOF IT 26.57 Roof:Carry out temporary repairs to any type of flat roof area as

required to ensure area is weatherproof, provide report to Client Representative.

Page 91: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

57 Local Space Housing

223005 U ROOF:SUPPLY AND FIX AND LATER REMOVE TARPAULIN SHEET NO 59.81 Roof:Supply and fix tarpaulin sheet approx 4x3m to roof as

temporary repair.

223009 U ROOF:TEMPORARY REPAIR CORRUGATED SHEET IT 23.67 Roof:Carry out temporary repairs to any type of corrugated sheet

area of roof as required to ensure area is weatherproof, provide report to Client Representative.

223011 U ROOF:FIX ROOF LEAK TO PITCHED ROOF IT 97.88 Roof:Carry out repair to any type of slate/tiled area of roof as

required to ensure area is weatherproof, including renew or refix any size and type of concrete interlocking or roof tile or any plain concrete or clay roof tile natural or fibre cement slates in patch to roof, including remove defective tiles or slates, fix new, replace felt and battens, and remove waste and debris, refix flashings, clear out gutters, provide report to Client Representative.

223013 U ROOF:FIX ROOF LEAK TO FLAT ROOF IT 142.46 Roof:Carry out repairs to any type of flat roof area as required to

ensure area is weatherproof, including repair patch ne 2.00sm in ‘Torch On’ felt roofing system including brush and clear away chippings, cut out defective layer of felt, heat new felt and lay and bond over adjacent layers, replace or renew chippings or cut out defective asphalt roof finish, renew membrane, lay asphalt in two layers and bond to existing asphalt asphalt, finish smooth to existing levels, and remove waste and debris, refix flashings, clear out gutters, provide report to Client Representative.

Sundry Items 225001 R FILLET:RENEW CEMENT MORTAR FILLET LM 10.83 Fillet:Hack off existing and renew cement mortar fillet (1:3) and

and remove suplus spoil.

225003 R ROOFING:SCREED ROOF SM 32.81 Roofing:Screed roof in cement and sand (1:3) including fixing and

striking shuttering and applying new bonding agent to surface.

Felt Roofing Felt Roofing - Two Layer 217001 R FELT:RENEW HP PLAIN OR MINERAL FINISH 2L SM 42.06 Felt:Renew felt roofing with two layer high performance felt

including strip and remove existing covering and prepare sub-base to receive new felt roofing, supply and lay two layer high performance felt roofing with plain or mineral surface finish to top layer including all kerbs, upstands, downstands, drips, angles, dressing into outlets, around pipes etc., and remove waste and debris

217003 R FELT:RENEW HP STONE CHIPPINGS 2L SM 54.19 Felt:Renew felt roofing with two layer high performance felt

including strip and remove existing covering and prepare sub-base to receive new felt roofing, supply and lay two layer high performance felt roofing with top layer plain finish with stone chippings bonded in bitumen dressing compound including all kerbs, upstands, upstands, downstands, drips, angles, dressing to outlets, around pipes and the like, and remove waste and debris.

Page 92: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

58 Local Space Housing

217005 R FELT:RENEW HP TORCH ON PLAIN OR MINERAL 2L SM 37.51 Felt:Renew felt roofing with two layer high performance 'Torch On'

felt including strip and remove existing covering and prepare sub-base to receive new felt roofing, supply and lay two layer high performance ‘Torch On’ felt roofing with plain or mineral surface finish to top layer including all kerbs, upstands, downstands, drips, angles, dressing to outlets, around pipes etc., and remove waste and debris

217007 R FELT:RENEW HP TORCH ON CHIPPINGS 2L SM 49.64 Felt:Renew felt roofing with two layer high performance 'Torch On'

felt including strip and remove existing covering and prepare sub-base to receive new felt roofing, supply and lay two layer performance ‘Torch On’ felt roofing with top layer plain finish with stone chippings bonded in bitumen dressing compound including all kerbs upstands, downstands, drips, angles, dressing to outlets, around pipes and the like, and remove waste and debris

217009 R FELT:REPAIR PATCH NE 2.0SM 2L IT 40.94 Felt:Repair patch ne 2.00sm including brush/clear away chippings,

cut out top layer of felt, cover with new felt and bond with bitumen to adjacent layers, relay chippings including renew if deficient, and remove waste and debris

217013 R FELT:REPAIR NE 2.0SM (TORCH ON) 2L IT 50.50 Felt:Repair patch ne 2.00sm with ‘Torch On’ felt roofing system, cut

out defective layer of felt, heat new felt and lay and bond over adjacent layers, relay chippings including renew if deficient, and remove waste and debris

217019 R FELT:REPAIR UPSTAND NE 300MM GIRTH 2L LM 27.12 Felt:Repair upstand ne 300mm girth including cut out top layer of

felt, cover with new mineral felt bond with bitumen to adjacent layers, rake out chase and repoint in cement mortar, and remove waste and debris

217021 R FELT:RENEW ANY GIRTH GUTTER 2L LM 26.54 Felt:Renew two layer felt to any girth gutter including remove

defective felt and lay new felt bedded in hot bitumen, and remove waste and debris.

217023 R FELT:SEAL ROOFING AROUND OUTLET NO 8.67 Felt:Seal around rainwater outlet with hot bitumen. 217025 R FELT:RENEW ALUMINIUM EDGING LM 25.16 Felt:Take off existing, clear away and renew preformed aluminium

edging including all angles and ends, dress felt roofing into groove, and remove waste and debris

217027 R FELT:FIX FLASHBAND NE 300MM GIRTH LM 15.44 Felt:Fix flashband upstand or skirting ne 300mm girth including

prime surface.

217029 R FELT:APPLY SOLAR REFLECT PAINT (PER COAT) SM 12.31 Felt:Prepare and apply solar reflective paint to general surfaces of

felt roofing (per coat).

Page 93: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

59 Local Space Housing

217031 R FELT:RENEW CHIPPINGS SM 24.99 Felt:Renew chippings to roof including remove old chippings and

clear away, apply cold compound and spread new chippings. (as sole job), and remove waste and debris

Felt Roofing - Three Layer 217101 R FELT:RENEW HP PLAIN OR MINERAL FINISH 3L SM 60.55 Felt:Renew felt roofing with three layer high performance felt

including strip and remove existing covering and prepare sub-base to receive new felt roofing, supply and lay three layer high performance felt roofing with plain or mineral surface finish to top layer including all kerbs, upstands, downstands, drips, angles, dressing into outlets, around pipes etc, and remove waste and debris.

217103 R FELT:RENEW HP STONE CHIPPINGS 3L SM 72.68 Felt:Renew felt roofing with three layer high performance felt

including strip and remove existing covering and prepare sub-base to receive new felt roofing, supply and lay three layer high performance felt roofing with top layer plain finish with stone chippings bonded in bitumen dressing compound including all kerbs, upstands, downstands, drips, angles, dressing to outlets, around pipes and the like, and remove waste and debris.

217105 R FELT:RENEW HP TORCH ON PLAIN OR MINERAL 3L SM 53.27 Felt:Renew felt roofing with three layer high performance 'Torch

On' felt including strip and remove existing covering and prepare sub-base to receive new felt roofing, supply and lay three layer high performance ‘Torch On’ felt roofing with plain or mineral surface finish to top layer including all kerbs, upstands, downstands, drips, angles, dressing to outlets, around pipes etc, and remove waste and debris.

217107 R FELT:RENEW HP TORCH ON CHIPPINGS 3L SM 65.41 Felt:Renew felt roofing with three layer high performance 'Torch

On' felt including strip and remove existing covering and prepare sub-base to receive new felt roofing, supply and lay three layer performance ‘Torch On’ felt roofing with top layer plain finish with stone chippings bonded in bitumen dressing compound including all kerbs, upstands, downstands, drips, angles, dressing to outlets, around pipes and the like, and remove waste and debris.

217109 R FELT:REPAIR PATCH NE 2.0SM 3L IT 80.22 Felt:Repair patch ne 2.00sm including brush/clear away chippings,

cut out top two layers of felt, cover with new felt and bond with bitumen to adjacent layers, relay chippings including renew if deficient, and remove waste and debris.

217113 R FELT:REPAIR NE 2.0SM (TORCH ON) 3L IT 67.92 Felt:Repair patch ne 2.00sm with torch on felt roofing system, cut

out defective top two layers of felt, heat new felt and lay and bond over adjacent layers, relay chippings including renew if deficient, and remove waste and debris.

217119 R FELT:REPAIR UPSTAND NE 300MM GIRTH 3L LM 35.82 Felt:Repair upstand ne 300mm girth including cut out top two

layers of felt, cover with new mineral felt bond with bitumen to adjacent layers, rake out chase and repoint in cement mortar, and remove waste and debris.

Page 94: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

60 Local Space Housing

217121 R FELT:RENEW ANY GIRTH GUTTER 3L LM 41.87 Felt:Renew three layer felt to any size gutter including remove

defective felt and lay new felt bedded in hot bitumen, and remove waste and debris.

Asphalt Roofing Asphalt Roof Coverings 219001 R ASPHALT:RENEW 20MM IN PATCH NE 2.0SM IT 239.57 Asphalt:Renew 20mm asphalt roof finish in patch ne 2.00sm, cut

out defective roof finish, renew isolating membrane, lay asphalt in two layers and bond to existing asphalt and finish smooth to match existing levels, and remove waste and debris.

219003 R ASPHALT:RENEW IN AREAS SM 99.02 Asphalt:Renew 20mm asphalt roof finish in areas comprising

isolating membrane, asphalt laid in two layers and bond to existing asphalt and finish smooth to match existing levels, and remove waste and debris.

219005 R ASPHALT:RENEW 25MM TO BALCONY SM 120.40 Asphalt:Renew asphalt to access balcony including take up existing

asphalt and underlay, lay 25mm two coat work to deck and gutter on new isolating membrane, 13mm two coat work to upstands, downstands and including chases cut into brickwork or concrete and pointed in cement mortar and dressing asphalt around outlets, gullies and the like (measured all inclusive area over horizontal surfaces only), and remove waste and debris.

219009 R ASPHALT:RENEW SKIRTING LM 47.55 Asphalt:Renew asphalt skirting ne 225mm high comprising 13mm

two coat asphalt laid direct to structural background including all angles, coves and fillets, turn top edge into prepared groove, and remove waste and debris.

219011 R ASPHALT:RENEW TO BOX GUTTER LM 156.28 Asphalt:Renew asphalt to any size box gutter including take up

existing and relay including renewal of gutter sole board if necessary, form all angle fillets, skirtings etc and turn into groove in and or tuck into metal edge trim, and remove waste and debris.

219013 R ASPHALT:MAKE GOOD CRACK NE 1.0M IT 24.49 Asphalt:Make good crack in asphalt ne 1.00m long, rake out, clean

up and iron in crack.

219015 R ASPHALT:MAKE GOOD CRACK OVER 1.0M LM 21.11 Asphalt:Make good crack in asphalt over 1.00m long, rake out,

clean up and iron in crack.

219017 R ASPHALT:REFORM COLLAR TO PIPES NO 31.84 Asphalt:Reform collar around pipes, balusters and the like in 20mm

two coat asphalt, work ne 140mm diameter and ne 100mm high.

219019 R ASPHALT:MAKE GOOD BLISTER IT 19.40 Asphalt:Cut out isolated blister in existing roof and make good in

asphalt to match existing including all bonding to adjacent surfaces, and remove waste and debris.

Page 95: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

61 Local Space Housing

219023 R ASPHALT:REFORM INTO OUTLET NO 52.11 Asphalt:Cut out as necessary and reform asphalt into any type and

or size of roof outlet including all bonding to adjacent surfaces and dressing into outlet, and remove waste and debris.

219025 R ASPHALT:APPLY SOLAR REFLECTIVE PAINT SM 12.31 Asphalt:Prepare and apply solar reflective paint to asphalt roofing

(per coat).

Sundry Works Loft Insulation 227005 R INSULATION:LAY UPTO 270MM THICK QUILT SM 14.84 Insulation:Supply and lay new upto 270mm thick insulation quilt to

loft area including gain access and moving/replacing contents within loft area in order to undertake work.

227007 R CLIENT INSPECTION:REMOVE AND RELAY INSULATION SM 6.92 Client Inspection:Remove, set aside and relay insulation quilt to loft

area including gain access and moving/replacing contents within loft area in order to undertake inspection (any repairs required to be ordered separately).

Roof Boarding 229001 R ROOF BOARDING:RENEW WOODWOOL SLABS SM 36.24 Roof Boarding:Renew 50mm woodwool slab finished with cement

slurry screed roof boarding, including denail rafters or joists, and remove waste and debris, punch in nails and level to existing and make good.

229003 R ROOF BOARDING:RENEW IN 19MM PLYWOOD SM 34.30 Roof Boarding:Renew 19mm WPB quality plywood roof boarding

including denail rafters or joists, and remove waste and debris, punch in nails and level to existing, and make good.

229005 R ROOF BOARDING:RENEW IN 18MM CHIPBOARD SM 26.44 Roof Boarding:Renew 18mm, V313 grade chipboard roof boarding

including denail rafters or joists, and remove waste and debris, punch in nails and level to existing, and make good.

229007 R ROOF BOARDING:RENEW IN 18MM PREFELTED PLYWOOD SM 27.98 Roof Boarding:Renew 18mm thick prefelted plywood decking

including denail rafters or joists, and remove waste and debris, punch in nails and level to existing, and make good tape joints and prepare to receive felt roofing.

229009 R ROOF BOARDING:RENEW TIMBER FIRRINGS LM 4.35 Roof Boarding:Renew ne 50x50mm tapered softwood firrings to

roof joists and remove waste and debris.

Page 96: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

62 Local Space Housing

Leadwork Lead Roof Coverings and Flashings - Code 4 231001 R SLATE:RENEW LEAD TO PIPE NO 89.33 Slate:Remove existing lead or proprietary slate to ne 150mm

diameter pipe and replace with 500x500mm lead slate with 200mm high collar to ne 150mm diameter pipe including all labours and remove waste and debris.

231003 R SLATE:RENEW PROPRIETARY TO PIPE NO 83.85 Slate:Remove existing lead or proprietary slate to ne 150mm

diameter pipe and replace with proprietary slate with ne 200mm high collar to ne 150mm diameter pipe including all labours and remove waste and debris.

231005 R FLASHING:RENEW LEAD COVER NE 150MM LM 36.25 Flashing:Renew lead cover flashing not exceeding 150mm girth,

clean out groove of brickwork, wedge with lead and repoint in mastic including all necessary labours and remove waste and debris.

231009 R FLASHING:RENEW LEAD STEPPED NE 225MM LM 71.30 Flashing:Renew lead stepped flashing not exceeding 225mm girth,

clean out groove of brickwork, wedge with lead and repoint in mastic including all necessary labours and remove waste and debris.

231011 R FLASHING:RENEW LEAD APRON NE 300MM LM 67.48 Flashing:Renew lead apron flashing not exceeding 300mm girth,

clean out groove of brickwork, wedge with lead and repoint in mastic including all necessary labours and remove waste and debris.

231013 R FLASHING:TAKE OFF AND REFIX LEAD LM 17.48 Flashing:Take off lead flashing, set aside, hack out pointing, clean

out groove of brickwork, refix flashing and wedge with lead and repoint in mastic

231015 R FLASHING:RAKE OUT AND REPOINT LEAD LM 10.56 Flashing:Rake out pointing of flashing and repoint in mastic 231017 R FIREWALL:RENEW LEAD FLASHINGS TO COPINGS LM 87.58 Firewall:Remove existing coping stones to firewall and remove

waste and debris, remove existing flashings to both sides of firewall and renew with new lead flashings including all dressing etc., supply and fix new pcc coping stones to suit, bedded and pointed in cement mortar (1:3) and point flashing in mastic.

231020 R GUTTER:RENEW LEAD LINING NE 500MM GIRTH LM 89.55 Gutter:Renew lead parapet gutter lining not exceeding 500mm

girth, clean out groove of brickwork, wedge with lead and repoint in mastic including all necessary labours and remove waste and debris.

231021 R VALLEY:RENEW LEAD GUTTER NE 800MM GIRTH LM 106.44 Valley:Renew lead valley gutter not exceeding 800mm girth,

remove and refix roof tiles or slates and battens as required, including all necessary labours and remove waste and debris.

Page 97: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

63 Local Space Housing

231023 R VALLEY:RENEW LEAD GUTTER AND BOARDS LM 160.75 Valley:Renew lead valley gutter not exceeding 800mm girth,

complete with valley boards and tilting fillets, remove and refix roof tiles or slates as required, including all necessary labours and remove waste and debris.

231025 R VALLEY:REPAIR LEAK TO LEADWORK IT 21.78 Valley:Repair leak in lead valley with wiped joint or soldered on

patch, remove and refix tiles and or slates as necessary. (measured per valley).

231027 R SOAKER:RENEW OR REFIX LEAD NO 16.00 Soaker:Renew or refix lead soaker not exceeding 250x330mm,

including all necessary labours and remove waste and debris.

231031 R ROOF:RENEW LEAD ROOF COVERING SM 157.57 Roof:Renew lead roof covering including remove old lead, cut, fit

and dress new roof covering including all nailing and caps, drips, welted edges, bossed ends and intersections and all labours and remove waste and debris.

231033 R PORCH:RENEW LEAD COVERING TO PORCH SM 171.41 Porch:Renew lead covering to porch including remove old lead, cut,

fit and dress new porch covering including all nailing and caps, drips, welted edges, bossed ends and intersections and all labours and remove waste and debris.

231035 R DORMERS:RENEW LEAD TO DORMERS SM 181.80 Dormers:Renew lead covering to dormers including remove old

lead, cut, fit and dress new covering including all nailing and caps, drips, welted edges, bossed ends and intersections and all labours and remove waste and debris.

231037 R BOW/BAY:RENEW LEAD FLAT ROOF NE 3.0SM IT 521.64 Bow/Bay:Renew lead covering to flat bow/bay roof ne 3.00sm

(measured on plan) including remove old lead, cut, fit and dress new covering including all nailing and caps, drips, welted edges, bossed ends and intersections, dressing to upstands and kerbs, clean out and reform grooves and wedge upstands with lead and repoint in mastic, cut and dress lead around rainwater outlets and remove waste and debris.

231039 R BOW/BAY:RENEW LEAD SLOPING ROOF NE 3.0SM IT 587.41 Bow/Bay:Renew lead covering to sloping bow/bay roof ne 3.00sm

(measured on slope) including remove old lead, cut, fit and dress new covering including all nailing and caps, drips, welted edges, bossed ends and intersections, dressing to upstands and kerbs, clean out/reform grooves and wedge upstands with lead and repoint in mastic, cut and dress lead around rainwater outlets and remove waste and debris.

Page 98: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

64 Local Space Housing

CARPENTRY AND JOINERY Floors, Roofs and Partitions Floors 301103 R JOIST:RENEW NE 100MM DEEP TO FLOOR LM 11.84 Joist:Renew with pressure impregnated sawn softwood floor joist

ne 100mm deep to match existing, cut out and clear away existing, cut new joist to length and fix including all packings, cleats, hangers, noggins, solid strutting etc., apply preservative to cut ends and cut out and make good brickwork as necessary and remove waste and debris.

301107 R JOIST:RENEW NE 225MM DEEP TO FLOOR LM 21.02 Joist:Renew with pressure impregnated sawn softwood floor joist

ne 225mm deep to match existing cut out and clear away existing, cut new joist to length and fix including all packings, cleats, hangers, noggins, solid strutting etc., apply preservative to cut ends and cut out and make good brickwork as necessary and remove waste and debris.

301109 R JOIST:LEVEL JOIST WITH PACKINGS NO 33.91 Joist:Level joist by inserting packings including take up floorboards

and refix, make good any finishes disturbed, remove and refix any carpets and furniture, (measured per joist), (not to be claimed in conjunction with joist renewal).

301122 R FLOOR:STRIP OUT FLOOR AND SLEEPERS SM 16.90 Floor:Strip out defective timber floor complete with any redundant

service installation attached or passing through floor, demolish sleeper walls down to sub-floor level, make good all works disturbed, and remove waste and debris, prepare to receive new solid floor (new floor measured separately).

301123 R FLOOR:RENEW GROUND FLOOR COMPLETE SM 136.34 Floor:Strip out existing floor and sleeper walls, remove void debris,

construct half brick sleeper walls in cement mortar (1:3) on concrete foundation including excavation and disposal and lay new softwood floor comprising 22mm square edge boards ne 50x125mm joists and ne 50x100mm wall plates including dpc, all in pretreated timber, and remove waste and debris.

301125 R FLOOR:RENEW SOFTWOOD FLOOR COMPLETE SM 82.20 Floor:Renew softwood floor comprising 22mm square edge boards,

ne 50x125mm joists and ne 50x100mm wall plates including dpc, all in pretreated timber, complete with galvanised joist hangers, cut and primed in, and remove waste and debris.

301127 R FLOOR:RENEW SOFTWOOD UPPER FLOOR COMPLETE SM 86.42 Floor:Renew softwood upper floor comprising 22mm square edge

boards ne 50x175mm joists and ne 50x100mm wall plates including dpc, 25x50mm strutting, all in pretreated timber, complete with galvanised joist hangers, cut and primed in, including trimming to openings, and remove waste and debris.

Page 99: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

65 Local Space Housing

301129 R FLOOR:CONSTRUCT SOFTWOOD FLOOR SM 66.89 Floor:Construct softwood floor comprising 22mm square edge

boards, ne 50x125mm joists and ne 50x100mm wall plates including dpc, in pretreated timber, complete with galvanised joist hangers, cut and primed in, and remove waste and debris.

301131 R FLOOR:CONSTRUCT SOFTWOOD UPPER FLOOR SM 71.10 Floor:Construct softwood upper floor comprising 22mm square

edge boards, ne 50x175mm joists and ne 50x100mm wall plates including dpc, 25x50mm strutting, all in pretreated timber, including trimming to openings in pretreated timber, complete with galvanised joists hangers, cut and primed in, and remove waste and debris.

Wall or Partitions 301301 R PARTITION:ERECT TIMBER STUD AND PLASTERBOARD BF SM 73.69 Partition:Supply and erect or renew stud partition comprising ne

50x100mm sole and head plate, noggins and studs fixed with nails or plugged and screwed to walls, and pack out and scribe, 12.5mm taper edged plasterboard scrim jointed and all labours to both faces.

301303 R PARTITION:ERECT TIMBER STUD PLASTERBOARD SKIM BS SM 84.09 Partition:Supply and erect or renew stud partition comprising ne

50x100mm sole and head plate, noggins and studs fixed with nails or plugged and screwed to walls, and pack out and scribe, 12.5mm butt jointed plasterboard and 3mm plaster skim coat and all labours to both faces.

301305 R PARTITION:INSTALLINSULATION INFILL NE 100MM SM 4.42 Partition:Supply and install insulation infill ne 100mm thick to stud

partition.

301307 R PARTITION:SOUND INFILL 75MM SM 7.51 Partition:Supply and install sound insulation infill 75mm thick to

stud partition.

301311 R PARTITION:ERECT METAL STUD AND PLASTERBOARD BF SM 50.29 Partition:Supply and erect or renew proprietary metal stud partition

comprising sole and head plate, noggins and studs fixed with nails or plugged and screwed to walls, and pack out and scribe, 12.5mm taper edged plasterboard scrim jointed and all labours to both faces.

301313 R PARTITION:METAL STUD PLASTERBOARD SKIM BF SM 57.10 Partition:Supply and erect or renew proprietary metal stud partition

comprising sole and head plate, noggins and studs fixed with nails or plugged and screwed to walls, and pack out and scribe, 12.5mm butt jointed plasterboard and 3mm plaster skim coat and all labours to both faces.

301315 R PARTITION:FILL IN OPENING IN TIMBER STUDDING SM 95.50 Partition:Fill in existing opening in stud partition with ne 50x100mm

sole and head plate, noggins and studs fixed with nails or plugged and screwed to walls, and pack out and scribe, 12.5mm taper edged plasterboard scrim jointed and all labours and provide skirting to match existing to both faces.

Page 100: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

66 Local Space Housing

301317 R PARTITION:FORM OPENING IN TIMBER STUDDING IT 101.01 Partition:Cut and form opening in existing stud partition plastered

both sides, frame up opening with 50x100mm head plate, noggins and studs fixed with nails or plugged and screwed to walls, and pack out and scribe, make good plasterboard and 3mm plaster skim coat, extend flooring through opening on bearers, make good all works disturbed and remove waste and debris.

Wall Plates 301501 R PLATE:RENEW 75X100MM WALL PLATE LM 9.31 Plate:Renew pressure impregnated sawn softwood wall plate ne

75x100mm, bedded in cement mortar (1:3) and apply preservative to cut ends, and remove waste and debris.

301503 R PLATE:RENEW 75X100MM WALL PLATE AND DPC LM 11.63 Plate:Renew pressure impregnated sawn softwood wall plate ne

75x100mm, bedded in cement mortar (1:3) and apply preservative to cut ends on and including polypropylene damp proof course 138mm girth, and remove waste and debris.

Roof Members 301701 R RAFTER:RENEW NE 175MM RAFTER OR JOIST LM 11.60 Rafter:Renew with pressure impregnated sawn softwood rafter/roof

joist, ne 175mm deep to match existing in roof space, cut new rafter or roof joist to length, apply preservative to cut ends, cut out and make good to brickwork as necessary and all hangers, drilling and bolting with connectors to existing rafters or joists, and remove waste and debris.

301703 R COLLAR/STRUT:RENEW NE 175MM THICK LM 15.98 Collar/Strut:Renew with pressure impregnated sawn softwood collar

or strut, ne 175mm thick to match existing in roof space, cut new collar to length, apply preservative to cut ends, and cut out and make good brickwork as necessary and all hangers, drilling and bolting with connectors to existing roof timbers, and remove waste and debris.

Joist Hangers 301901 R HANGER:RENEW GALVANISED JOIST HANGER NO 6.96 Hanger:Renew galvanised joist hanger, cut out, bed in mortar and

make good brickwork, renew in conjunction with joist repairs.

301903 R HANGER:CUT OUT AND INSERT JOIST HANGER IT 10.46 Hanger:Cut out and insert galvanised steel joist hanger to correct

floor alignment, bed in mortar, pin, make good brickwork, renew in conjunction with floor or joist repairs.

Page 101: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

67 Local Space Housing

Fascia, Soffit and Bargeboards Fascias, Soffit and Bargeboards - Timber 303001 R FASCIA:RENEW IN SOFTWOOD NE 300MM LM 36.03 Fascia/Barge:Renew fascia or barge with preservative treated

softwood, ne 300mm wide, fixed to roof timbers, apply preservative to cut ends, remove and refix rainwater goods and any cabling, adjust roof tiles and felt, renewal of any support battens and all mitred joints and decorate to match existing and remove waste and debris.

303003 R FASCIA:RENEW IN WBP PLYWOOD NE 300MM LM 33.94 Fascia/Barge:Renew fascia or barge with WPB external quality

plywood, ne 300mm wide fixed to roof timbers, apply preservative to cut ends, remove and refix rainwater goods and any cabling, adjust roof tiles and felt, renewal of any support battens and all mitred joints and decorate to match existing and remove waste and debris.

303007 R SOFFIT:RENEW IN SOFTWOOD NE 450MM LM 35.45 Soffit:Renew soffit board with treated softwood ne 450mm wide

including renew noggins as necessary fixed to roof timbers and refix cables and decorate to match existing and remove waste and debris.

303009 R SOFFIT:RENEW IN PLYWOOD NE 450MM LM 34.56 Soffit:Renew soffit board with WPB plywood ne 450mm wide

including renew noggins as necessary fixed to roof timbers and refix cables and decorate to match existing and remove waste and debris..

303011 R SOFFIT:RENEW IN MASTERBOARD NE 450MM LM 48.67 Soffit:Renew soffit board with masterboard ne 450mm wide

including renew noggins as necessary fixed to roof timbers and refix cables and decorate to match existing and remove waste and debris.

303015 R FASCIA/SOFFIT/BARGE:REFIX LM 26.98 Fascia/Soffit/Barge:Refix any size fascia, soffit or bargeboard to

existing roof timbers including remove and refix rainwater goods and cabling as necessary, renewal of support battens, all cutting and packing and make good decorations.

303017 R BOXED END:RENEW TO FASCIA AND SOFFIT NO 46.00 Boxed End:Renew boxed end to fascia and soffit including renewing

as required timber supports, new WPB plywood soffit, fascia etc and all cutting and shaping and jointing to existing fascias, soffits etc., and decorate to match existing and remove waste and debris..

Fascias, Soffits and Bargeboards - PVCu 303005 R FASCIA/BARGE:RENEW IN PVCU NE 300MM LM 25.67 Fascia/Barge:Renew fascia or bargeboard with proprietary PVCu

board ne 300mm wide fixed to roof timbers, remove and refix rainwater goods and any cabling, remove existing board, adjust roof tiles and felt, renewal of any support battens and all joints, including all cutting and packing to ensure line and level and remove waste and debris.

Page 102: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

68 Local Space Housing

303013 R SOFFIT:RENEW IN PVCU NE 450MM LM 30.27 Soffit:Renew soffit board with PVCu board ne 450mm wide

including remove existing, renew noggins as necessary and fix new board to roof timbers and refix cables and remove waste and debris.

303019 R BOXED END:RENEW IN PVCU TO FASCIA AND SOFFIT NO 45.90 Boxed End:Renew boxed end to fascia and soffit including renewing

as required timber supports, new proprietary PVCu board soffit, fascia etc. and all cutting and shaping and jointing to existing fascias, soffits etc., and remove waste and debris.

Rainwater Gutters - Timber 303101 R GUTTER:RENEW NE 150X100MM TIMBER LM 24.72 Gutter:Renew in ne 150x100mm moulded timber gutter including support

brackets fixed to fascia, all cutting, make joints, line, level and connections to existing guttering and remove waste and debris.

303102 R GUTTER:REALIGN TIMBER GUTTER LM 10.20 Gutter:Take down any timber gutter, remove and refix brackets to fascia

and refix gutter to brackets including all angles, outlets, stop ends and remake all joints and remove waste and debris.

303103 R GUTTER:FORM STOP END NO 8.57 Gutter:Form stop end to timber gutter. 303104 R GUTTER:FORM OUTLET NO 38.56 Gutter:Cut hole in timber gutter, form outlet and fix nozzle spitter. 303105 R GUTTER:RENEW CAST IRON BRACKET TO TIMBER GUTTER NO 7.85 Gutter:Renew cast iron bracket of any profile including remaking joints

and line and level, and remove waste and debris.

303106 R GUTTER:RENEW TIMBER BRACKET NO 13.96 Gutter:Renew timber bracket of any profile including remaking joints and

line and level, and remove waste and debris.

Flooring Flooring - Rigid Sheet - WPB Plywood 305101 U FLOORING:RENEW IN 19MM PLYWOOD SM 29.91 Flooring:Renew any flooring with 19mm WBP plywood including

denial joists, and remove waste and debris, punch in nails, level to existing and make good including additional noggins and support battens as required.

305103 R FLOORING:RENEW IN 6MM PLYWOOD SM 20.20 Flooring:Renew any flooring with 6mm WBP plywood including

denail joists, and remove waste and debris, punch in nails, level to existing and make good including additional noggins and support battens as required.

305105 R FLOORING:SUPPLY AND LAY 4MM PLYWOOD SM 20.20 Flooring:Supply and lay 4mm WBP plywood nailed to existing

floorboard at 150mm centres with wired nails and level as necessary.

Page 103: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

69 Local Space Housing

Flooring - Rigid Sheet - Flooring Grade Chipboard 305301 U FLOORING:RENEW IN 19MM CHIPBOARD SM 27.10 Flooring:Renew any flooring with 19mm flooring grade V313

waterproof chipboard including denail joists, and remove waste and debris, punch in nails, level to existing and make good including additional noggins and support battens as necessary.

305303 U FLOORING:RENEW IN INSULATED CHIPBOARD SM 33.14 Flooring:Renew any flooring with flooring grade V313 waterproof

insulating chipboard including denail joists, and remove waste and debris, punch in nails and level to existing and make good including additional noggins and support battens necessary.

Flooring - Rigid Sheet - Hardboard 305501 R FLOORING:SUPPLY AND LAY HARDBOARD SM 9.73 Flooring:Supply and lay 3.2mm flooring grade hardboard nailed to

existing floorboard at 150mm centres with wired nails and level as necessary.

Flooring - Timber Board 305701 U FLOORBOARD:RENEW NE 1.0SM IT 56.77 Floorboard:Renew to match existing any flooring with 19mm

tongued and grooved or square edged flooring in area ne 1.00sm, including denail joists, and remove waste and debris, punch in nails, level level to existing and make good including any extra support noggins required.

305703 U FLOORBOARD:RENEW OVER 1.0SM SM 54.62 Floorboard:Renew to match existing any flooring with 19mm

tongued and grooved or square edged flooring in area over 1.00sm including denail joists, and remove waste and debris, punch in nails, level to existing and make good including any extra support noggins required.

305704 R FLOORBOARDS:REMOVE AND REFIX AREA SM 18.23 Floorboard:Remove and later refix any area of boards, including

denail joists, and remove waste and debris, punch in nails, level to existing and make good including any extra noggins required.

305705 R FLOORBOARD:REMOVE AND REFIX SINGLE BOARD LM 4.42 Floorboard:Remove and later refix any boards, including denail

joists and remove waste and debris, punch in nails, level to existing and make good including any extra noggins required.

305706 R FLOORBOARD:SCREW DOWN PER ROOM IT 5.10 Floorboard:Screw down any width loose floorboards in any room

including providing fixing batten to side of joist where end of board is unsupported (Per Room).

305709 R FLOORING:APPLY 2 COATS PRESERVATIVE SM 9.05 Preservative:Prepare and brush apply two coats of approved

preservative to general surfaces of flooring.

Page 104: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

70 Local Space Housing

Flooring - Wood Block 306001 R FLOORING:RENEW WOOD BLOCK NE 2.0SM IT 152.11 Flooring:Renew wood block floor in patches ne 2.00sm including

take up existing and clear away, lay new 25mm thick flooring with tongued and grooved joints fixed with adhesive and laid to herring bone pattern including make good at junction with existing finishes and remove waste and debris.

306003 R FLOORING:RENEW WOOD BLOCK OVER 2.0SM SM 101.40 Flooing:Renew wood block floor in patches over 2.00sm including

take up existing and clear away, lay new 25mm thick flooring with tongued and grooved joints fixed with adhesive and laid to herring bone pattern including make good at junction with existing finishes and remove waste and debris.

External Cladding Cladding - Timber Weatherboarding - Shiplap 307101 R CLADDING:RENEW 19MM SHIPLAP NE 2.0SM IT 69.31 Cladding:Remove existing defective shiplap boarding and renew

with 19mm pressure impregnated shiplap boarding in areas ne 2.00sm including all labours, fixed to existing framework including renew defective support battens and provide any extra battens required and decorate to match existing, and remove waste and debris.

307103 R CLADDING:RENEW 19MM SHIPLAP OVER 2.0SM SM 37.64 Cladding:Remove existing cladding and renew with 19mm pressure

impregnated shiplap boarding in areas over 2.00sm including all labours, fixed to existing framework including renew defective support battens and provide any extra battens required and decorate to match existing, and remove waste and debris.

307105 R CLADDING:REFIX LOOSE SHIPLAP, FEATHER EDGE OR TGV SM 9.04 Cladding:Refix loose timber shiplap, feather edge or T, G and V

jointed boarding to existing framework including renewal of any support battens required and make good decorations.

Cladding - Timber Weatherboarding - Feather Edge 307301 R CLADDING:RENEW FEATHER EDGE NE 2.0SM IT 65.42 Cladding:Remove existing defective feather edge boarding and

renew with 19mm pressure impregnated feather edge boarding in areas ne 2.00sm including all labours, fixed to existing framework including renew defective support battens and provide any extra battens required and decorate to match existing, and remove waste and debris.

307303 R CLADDING:RENEW FEATHER EDGE OVER 2.0SM SM 35.51 Cladding:Remove existing cladding and renew with 19mm pressure

impregnated feather edge boarding to match existing in areas over 2.00sm including all labours, fixed to existing framework including renew defective support battens and provide any extra battens required and decorate to match existing, and remove waste and debris.

Page 105: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

71 Local Space Housing

Cladding - Timber Weatherboarding - Softwood Tongued, Grooved and V Jointed

307501 R CLADDING:RENEW T G AND V JOINT NE 2.0SM IT 81.78 Cladding:Remove existing defective tongued, grooved and 'V'

jointed boarding and renew with 19mm pressure impregnated tongued, grooved and V jointed boarding in areas ne 2.00sm including all labours, fixed to existing framework, renew defective support battens and provide extra battens required and decorate to match existing, and remove waste and debris.

307503 R CLADDING:RENEW T G AND V JOINT OVER 2.0SM SM 47.21 Cladding:Remove existing boarding and renew with 19m tongued,

grooved and V jointed pressure impregnated softwood boarding, including all labours, in areas over 2.00sm fixed to existing framework, renew defective support battens and provide extra battens required and decorate to match existing, and remove waste and debris.

Cladding - Plastic Profiled Sheet Cladding - Shiplap 307701 R CLADDING:RENEW PVC SHIPLAP NE 2.0SM IT 81.37 Cladding:Remove existing defective PVC shiplap cladding and renew

with cellular cored PVC shiplap boarding in areas ne 2.00sm including all trims, channels and jointing, fixed to existing framework including renew defective support battens and provide any extra battens required and remove waste and debris.

307703 R CLADDING:RENEW PVC SHIPLAP OVER 2.0SM SM 44.94 Cladding:Renew any cladding with cellular cored PVC shiplap

boarding, in areas over 2.00sm including all trims, channels and jointing, fixed to existing framework including renew defective support battens and provision of extra battens as necessary and remove waste and debris.

307705 R CLADDING:REFIX LOOSE PVC SHIPLAP OR TGV SM 10.20 Cladding:Refix loose PVC shiplap or T, G and V jointed cladding to

existing framework including renewal of support battens required and all trims, channels and jointing.

Windows Windows - Casement - Standard Softwood Double Glazed 310101 R WINDOW:RENEW STANDARD SOFTWOOD CASEMENT 1 LIGHT SM 275.73 Window:Renew timber window with standard softwood casement

window with softwood cill, including ne 1 No. opening light, factory applied base stain or primer finish, compressible weatherstripping, ironmongery including locking handles, glazing beads, windows preslotted for trickle ventilators including screens, remove existing frame and fix new in prepared opening, bed in mortar and point with sealant, double glazed, make good to all finishes and decorate to match existing internally and externally and remove waste and debris.

Page 106: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

72 Local Space Housing

310105 R WINDOW:RENEW STANDARD SOFTWOOD CASEMENT 2 LIGHT SM 316.47 Window:Renew timber window with standard softwood casement

window with softwood cill, including ne 2 No. opening light, factory applied base stain or primer finish, compressible weatherstripping, ironmongery including locking handles, glazing beads, windows preslotted for trickle ventilators including screens, remove existing frame and fix new in prepared opening, bed in mortar and point with sealant, double glazed, make good to all finishes and decorate to match existing internally and externally and remove waste and debris.

310109 R WINDOW:RENEW STANDARD SOFTWOOD CASEMENT 3 LIGHT SM 392.02 Window:Renew timber window with standard softwood casement

window with softwood cill, including ne 3 No. opening light, factory applied base stain or primer finish, compressible weatherstripping, ironmongery including locking handles, glazing beads, windows preslotted for trickle ventilators including screens, remove existing frame and fix new in prepared opening, bed in mortar and point with sealant, double glazed, make good to all finishes and decorate to match existing internally and externally and remove waste and debris.

310113 R WINDOW:RENEW STANDARD SOFTWOOD CASEMENT 4 LIGHT SM 426.27 Window:Renew timber window with standard softwood casement

window with softwood cill including ne 4 No. opening light, factory applied base stain or primer finish, compressible weatherstripping, ironmongery including locking handles, glazing beads, windows preslotted for trickle ventilators including screens, remove existing frame and fix new in prepared opening, bed in mortar and point with sealant, double glazed, make good to all finishes and decorate to match existing internally and externally and remove waste and debris.

Windows - Casement - Purpose Made Softwood Double

Glazed

310301 R WINDOW:RENEW PURPOSE SOFTWOOD CASEMENT 1 LIGHT SM 307.06 Window:Renew timber window with purpose made softwood

casement window with softwood cill including ne 1 No. opening light, factory applied base stain or primer finish, compressible weatherstripping, ironmongery including locking handles, glazing beads, windows preslotted for trickle ventilators including screens, remove existing frame and fix new in prepared opening, bed in mortar and point with sealant, double glazed, make good to all finishes and decorate to match existing internally and externally and remove waste and debris.

310305 R WINDOW:RENEW PURPOSE SOFTWOOD CASEMENT 2 LIGHT SM 380.51 Window:Renew timber window with purpose made softwood

casement window with softwood cill including ne 2 No. opening light, factory applied base stain or primer finish, compressible weatherstripping, ironmongery including locking handles, glazing beads, windows preslotted for trickle ventilators including screens, remove existing frame and fix new in prepared opening, bed in mortar and point with sealant, double glazed, make good to all finishes and decorate to match existing internally and externally and remove waste and debris.

Page 107: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

73 Local Space Housing

310309 R WINDOW:RENEW PURPOSE SOFTWOOD CASEMENT 3 LIGHT SM 490.84 Window:Renew timber window with purpose made softwood

casement window with softwood cill including ne 3 No. opening light, factory applied base stain or primer finish, compressible weatherstripping, ironmongery including locking handles, glazing beads, windows preslotted for trickle ventilators including screens, remove existing frame and fix new in prepared opening, bed in mortar and point with sealant, double glazed, make good to all finishes and decorate to match existing internally and externally and remove waste and debris.

310313 R WINDOW:RENEW PURPOSE SOFTWOOD CASEMENT 4 LIGHT SM 563.81 Window:Renew timber window with purpose made softwood

casement window with softwood cill including ne 4 No. opening light, factory applied base stain or primer finish, compressible weatherstripping, ironmongery including locking handles, glazing beads, windows preslotted for trickle ventilators including screens, remove existing frame and fix new in prepared opening, bed in mortar and point with sealant, double glazed, make good to all finishes and decorate to match existing internally and externally and remove waste and debris.

Windows - Box Sash - Purpose Made Softwood Double

Glazed

310501 R WINDOW:RENEW SOFTWOOD BOX SASH SM 474.38 Window:Renew window with purpose made softwood double hung

cased box frame and sashes complete with 2 sashes, factory applied base stain or primer finish, compressible weatherstripping, glazing beads, ironmongery, remove existing and fix new into prepared opening, bed in mortar, point with sealant, double glazed and make good all finishes and decorations to match existing internally and externally and remove waste and debris.

Windows - Horizontal Pivot Hung - Purpose Made Softwood

Double Glazed

310701 R WINDOW:RENEW SOFTWOOD HORIZONTAL PIVOT SM 384.60 Window:Renew window with purpose made softwood horizontal

pivot hung window complete, factory applied base stain or primer finish, compressible weatherstripping, glazing beads, ironmongery, fix frame to prepared opening, bed in mortar and point with sealant, double glazed, make good all finishes and decorate to match existing internally and externally and remove waste and debris.

Windows - Casement - Standard Hardwood Double Glazed 311101 R WINDOW:RENEW STANDARD HARDWOOD CASEMENT 1 LIGHT SM 370.75 Window:Renew timber window with standard hardwood casement

window with hardwood cill, including ne 1 No. opening light, factory applied base stain finish, compressible weatherstripping, ironmongery including locking handles, glazing beads, windows preslotted for trickle ventilators including screens, remove existing frame and fix new in prepared opening, bed in mortar and point with sealant, double glazed, make good to all finishes and decorate to match existing internally and externally and remove waste and debris.

Page 108: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

74 Local Space Housing

311105 R WINDOW:RENEW STANDARD HARDWOOD CASEMENT 2 LIGHT SM 443.76 Window:Renew timber window with standard hardwood casement

window with hardwood cill, including ne 2 No. opening light, factory applied base stain finish, compressible weatherstripping, ironmongery including locking handles, glazing beads, windows preslotted for trickle ventilators including screens, remove existing frame and fix new in prepared opening, bed in mortar and point with sealant, double glazed, make good to all finishes and decorate to match existing internally and externally and remove waste and debris.

311109 R WINDOW:RENEW STANDARD HARDWOOD CASEMENT 3 LIGHT SM 599.61 Window:Renew timber window with standard hardwood casement

window with hardwood cill including ne 3 No. opening light, factory applied base stain, compressible weatherstripping, ironmongery including locking handles, glazing beads, windows preslotted for trickle ventilators including screens, remove existing and fix new in prepared opening, bed in mortar and point with sealant, double glazed, make good to all finishes and decorate to match existing internally and externally and remove waste and debris.

311113 R WINDOW:RENEW STANDARD HARDWOOD CASEMENT 4 LIGHT SM 648.62 Window:Renew timber window with standard hardwood casement

window with hardwood cill including ne 4 No. opening light, factory applied base stain, compressible weatherstripping, ironmongery including locking handles, glazing beads, windows preslotted for trickle ventilators including screens, remove existing and fix new in prepared opening, bed in mortar and point with sealant, double glazed, make good to all finishes and decorate to match existing internally and externally and remove waste and debris.

Windows - Casement - Purpose Made Hardwood Double

Glazed

311301 R WINDOW:RENEW PURPOSE HARDWOOD CASEMENT 1 LIGHT SM 404.26 Window:Renew timber window with purpose made hardwood

casement window with hardwood cill including ne 1 No. opening light, factory applied base stain, compressible weatherstripping, ironmongery including locking handles, glazing beads, windows preslotted for trickle ventilators including screens, remove existing frame and fix new in prepared opening, bed in mortar and point with sealant, double glazed, make good to all finishes and decorate to match existing internally and externally and remove waste and debris.

311305 R WINDOW:RENEW PURPOSE HARDWOOD CASEMENT 2 LIGHT SM 527.43 Window:Renew timber window with purpose made hardwood

casement window with hardwood cill including ne 2 No. opening light, factory applied base stain, compressible weatherstripping, ironmongery including locking handles, glazing beads, windows preslotted for trickle ventilators including screens, remove existing frame and fix new in prepared opening, bed in mortar and point with sealant, double glazed, make good to all finishes and decorate to match existing internally and externally and remove waste and debris.

Page 109: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

75 Local Space Housing

311309 R WINDOW:RENEW PURPOSE HARDWOOD CASEMENT 3 LIGHT SM 770.15 Window:Renew timber window with purpose made hardwood

casement window with hardwood cill including ne 3 No. opening light, factory applied base stain, compressible weatherstripping, ironmongery including locking handles, glazing beads, preslotted for trickle ventilators including screens, remove existing frame and fix new in prepared opening, bed in mortar and point with sealant, double glazed, make good to all finishes and decorate to match existing internally and externally and remove waste and debris.

311313 R WINDOW:RENEW PURPOSE HARDWOOD CASEMENT 4 LIGHT SM 889.50 Window:Renew timber window with purpose made hardwood

casement window with hardwood cill including ne 4 No. opening light, factory applied base stain, compressible weatherstripping, ironmongery including locking handles, glazing beads, preslotted for trickle ventilators including screens, remove existing frame and fix new in prepared opening, bed in mortar and point with sealant, double glazed, make good to all finishes and decorate to match existing internally and externally and remove waste and debris.

Windows - Box Sash - Purpose Made Hardwood Double

Glazed

311501 R WINDOW:RENEW HARDWOOD BOX SASH SM 735.70 Window:Renew window with purpose made hardwood double hung

cased box frame and sashes complete with 2 sashes, complete with factory applied base stain, compressible weatherstripping, glazing beads, ironmongery, remove existing and fix new into prepared opening, bed in mortar, point with sealant, double glazed and make good all finishes and decorations to match existing internally and externally and remove waste and debris.

Windows - Horizontal Pivot Hung - Purpose Made

Hardwood

311701 R WINDOW:RENEW HARDWOOD HORIZIONTAL PIVOT SM 554.81 Window:Renew window with purpose made hardwood horizontal

pivot hung window complete with factory applied base stain, compressible weatherstripping, glazing beads, ironmongery, fix frame to prepared opening, bed in mortar and point with sealant, double glazed, make good all finishes and decorate to match existing internally and externally and remove waste and debris.

Windows - Feature - Softwood 312001 R WINDOW:RENEW SOFTWOOD FEATURE SM 320.90 Window:Renew timber window with standard softwood feature

window ne 5.00sm overall with combination of fixed and opening lights and panels, factory applied base stain or primer finish, compressible weatherstripping, ironmongery including locking handles, glazing beads, windows preslotted for trickle ventilators including screens, remove existing frame and fix new in prepared opening, bed in mortar and point with sealant, double glazed, make good to all finishes and decorate to match existing internally and externally and remove waste and debris.

Page 110: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

76 Local Space Housing

Windows - Feature - Hardwood 313001 R WINDOW:RENEW HARDWOOD FEATURE SM 419.34 Window:Renew timber window with standard hardwood feature

window ne 5.00sm overall with combination of fixed and opening lights and panels, factory applied base stain finish, compressible weatherstripping, ironmongery including locking handles, glazing beads, windows preslotted for trickle ventilators including screens, remove existing frame and fix new in prepared opening, bed in mortar and point with sealant, double glazed, make good to all finishes and decorate to match existing internally and externally and remove waste and debris.

Window and Door Frames - Combination - Softwood 341301 R FRAME:RENEW SOFTWOOD COMBINATION UNIT SM 333.23 Frame:Renew window/door frame unit with standard softwood unit

including ne 2 No. opening lights, factory applied base stain or primer finish, compressible weatherstripping, ironmongery including locking handles, glazing beads, windows preslotted for trickle ventilators including screens, remove existing frame and fix new in prepared opening, bed in mortar and point with sealant, double glazed, make good to all finishes and decorate to match existing internally and externally and remove waste and debris. (remove/rehang existing door or renew door to be ordered separately).

Window and Door Frames - Combination - Hardwood 341501 R FRAME:RENEW HARDWOOD COMBINATION UNIT SM 437.44 Frame:Renew window/door frame unit with standard hardwood unit

including ne 2 No. opening lights, factory applied base stain, compressible weatherstripping, ironmongery including locking handles, glazing beads, windows preslotted for trickle ventilators including screens, remove existing frame and fix new in prepared opening, bed in mortar and point with sealant, double glazed, make good to all finishes and decorate to match existing internally and externally and remove waste and debris. (remove/rehang existing door or renew door to be ordered separately).

Windows - Horizontal Pivot Hung - Purpose Made PVCu 313501 R WINDOW:RENEW WITH PVCU PIVOT SM 255.36 Window:Renew any type window with purpose made PVCu factory

glazed horizontal pivot hung window complete with cill, double glazed internally with 20mm thick hermetically sealed units, omplete with thermal breaks, compressible weatherstripping, ironmongery including stainless steel friction hinges, espagnolette locking mechanism with locking handles, child restrictors, glazing beads, trickle ventilators including screens, remove existing and fix new to prepared opening using cleats or screw bolts, seal around externally with flexible foam strip and silicone sealant, make good all finishes internally and externally and remove waste and debris.

Page 111: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

77 Local Space Housing

Windows - Casement - Purpose Made PVCu 313601 R WINDOW:RENEW WITH PVCU CASEMENT 1 LIGHT NO 251.23 Window:Renew any type window with purpose made PVCu factory

glazed casement window with cill, double glazed internally with 20mm thick hermetically sealed units, including ne 1 No. opening light, thermal breaks, compressible weatherstripping, ironmongery including stainless steel friction hinges, espagnolette locking mechanism with locking handles, child restrictors, glazing beads, trickle ventilators including screens, remove existing and fix new to prepared opening using cleats or screw bolts, seal around externally with flexible foam strip and silicone sealant, make good all finishes internally and externally and remove waste and debris.

313605 R WINDOW:RENEW WITH PVCU CASEMENT 2 LIGHT SM 354.43 Window:Renew any type window with purpose made PVCu factory

glazed casement window with cill, double glazed internally with 20mm thick hermetically sealed units, including ne 2 No. opening light thermal breaks, compressible weatherstripping, ironmongery including stainless steel friction hinges, espagnolette locking mechanism with locking handles, child restrictors, glazing beads, trickle ventilators including screens, remove existing and fix new to prepared opening using cleats or screw bolts, seal around externally with flexible foam strip and silicone sealant, make good all finishes internally and externally and remove waste and debris.

313609 R WINDOW:RENEW WITH PVCU CASEMENT 3 LIGHT SM 446.24 Window:Renew any type window with purpose made PVCu factory

glazed casement window with cill, double glazed internally with 20mm thick hermetically sealed units, including ne 3 No. opening lights, thermal breaks, compressible weatherstripping, ironmongery including stainless steel friction hinges, espagnolette locking mechanism with locking handles, child restrictors, glazing beads, trickle ventilators including screens, remove existing and fix new to prepared opening using cleats or screw bolts, seal around externally with flexible foam strip and silicone sealant, make good all finishes internally and externally and remove waste and debris.

313613 R WINDOW:RENEW WITH PVCU CASEMENT 4 LIGHT SM 486.61 Window:Renew any type window with purpose made PVCu factory

glazed casement window with cill, double glazed internally with 20mm thick hermetically sealed units, including ne 4 No. opening lights, thermal breaks, compressible weatherstripping, ironmongery including stainless steel friction hinges, espagnolette locking mechanism with locking handles, child restrictors, glazing beads, trickle ventilators including screens, remove existing and fix new to prepared opening using cleats or screw bolts, seal around externally with flexible foam strip and silicone sealant, make good all finishes internally and externally and remove waste and debris.

Page 112: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

78 Local Space Housing

Windows - Tilt and Turn - Purpose Made PVCu 313701 R WINDOW:RENEW WITH PVCU TILT TURN 1 LIGHT SM 193.77 Window:Renew any type window with purpose made PVCu factory

glazed tilt/turn window with cill, double glazed internally with 20mm thick hermetically sealed units, including ne 1 No. opening light, thermal breaks, compressible weatherstripping, ironmongery including stainless steel tilt and turn gear, espagnolette locking system with locking handles, glazing beads, trickle ventilators including screens, , remove existing and fix new to prepared opening using cleats or screw bolts, seal around externally with flexible foam strip and silicone sealant, make good all finishes internally and externally and remove waste and debris.

313705 R WINDOW:RENEW WITH PVCU TILT TURN 2 LIGHT SM 298.15 Window:Renew any type window with purpose made PVCu factory

glazed tilt/turn window with cill, double glazed internally with 20mm thick hermetically sealed units, including ne 2 No. opening lights, thermal breaks, compressible weatherstripping, ironmongery including stainless steel tilt and turn gear, espagnolette locking system with locking handles, glazing beads, trickle ventilators including screens, , remove existing and fix new to prepared opening using cleats or screw bolts, seal around externally with flexible foam strip and silicone sealant, make good all finishes internally and externally and remove waste and debris.

313709 R WINDOW:RENEW WITH PVCU TILT TURN 3 LIGHT SM 448.34 Window:Renew any type window with purpose made PVCu factory

glazed tilt/turn window with cill, double glazed internally with 20mm thick hermetically sealed units, including ne 3 No. opening lights, thermal breaks, compressible weatherstripping, ironmongery including stainless steel tilt and turn gear, espagnolette locking system with locking handles, glazing beads, trickle ventilators including screens, , remove existing and fix new to prepared opening using cleats or screw bolts, seal around externally with flexible foam strip and silicone sealant, make good all finishes internally and externally and remove waste and debris.

313713 R WINDOW:RENEW WITH PVCU TILT TURN 4 LIGHT SM 460.04 Window:Renew any type window with purpose made PVCu factory

glazed tilt/turn window with cill, double glazed internally with 20mm thick hermetically sealed units, including ne 4 No. opening lights, thermal breaks, compressible weatherstripping, ironmongery including stainless steel tilt and turn gear, espagnolette locking system with locking handles, glazing beads, trickle ventilators including screens, remove existing and fix new to prepared opening using cleats or screw bolts, seal around externally with flexible foam strip and silicone sealant, make good all finishes internally and externally and remove waste and debris.

Window and Door Frames - Combination - PVCu 341607 R FRAME:RENEW PVCU COMBINATION UNIT SM 267.86 Frame:Renew screen/door frame/screen unit with PVCu factory

glazed combination unit, thermal breaks, compressible weatherstripping, ironmongery etc., fixed lights double glazed with 20mm hermetically sealed units, remove existing and fix new to prepared opening using cleats or screw bolts, seal around externally with flexible foam strip and silicone sealant, make good all finishes internally and externally and remove waste and debris.

Page 113: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

79 Local Space Housing

Windows - Single Glazing 314003 R GLAZING:DISCOUNT FOR SINGLE GLAZING SM -20.72 Glazing:Discount for provide and fix any combination of single

glazing in lieu of double glazing to timber windows including all adjustments to frames, sashes and the like (measured per nett square metre glass area or fraction thereof).

Windows - Timber - Repairs 315001 R WINDOW:EASE AND ADJUST INCLUDING REMOVE NO 13.49 Window:Ease any size and type of opening sash, pivot sash, sliding

sash including remove and refix sash, beads etc, oil and adjust hinges and ironmongery as necessary, touch up decoration to match existing, test to ensure effective operation.

315007 R WINDOW:RENEW NE 0.9X0.6M CASEMENT SINGLE GLAZED NO 117.10 Window:Renew ne 900x600mm casement with preservative treated

softwood casement, consisting of any size or profile members to match existing and hanging on new pair of 50mm steel butt storm hinges, single glazed and decorate to match existing and remove waste and debris.

315009 R WINDOW:RENEW FIXED SASH NE 0.9X0.6M SING GLAZED NO 101.86 Sash:Renew ne 900x600mm fixed sash with preservative treated

softwood sash, consisting of any size or profile members to match existing and bedded in linseed oil putty and screw fixed to frame, single glazed and decorate to match existing and remove waste and debris.

315011 R WINDOW:RENEW PIVOT SASH SINGLE GLAZED NO 178.59 Window:Renew pivot sash with preservative treated softwood pivot,

consisting of any size or profile to match existing framing and hanging on new pair of pivot hinges, single glazed and decorate to match existing and remove waste and debris.

315013 R WINDOW:RENEW SLIDING SASH SINGLE GLAZED NO 219.44 Window:Renew preservative treated softwood sliding sash to box

sash window, any size or profile to match existing, complete with cords, ease and adjust, single glazed and decorate to match existing and remove waste and debris.

314005 R WINDOW:EXTRA FOR DOUBLE GLAZING IN REPAIRS SM 20.72 Window:Extra for provide and fix any combination of double glazed

units in lieu of single glazing to renewed timber window sashes, casements and the like including all necessary adjustments to frames, frames, sashes, casements and the like (measured per nett square metre glass area or fraction thereof).

315015 R WINDOW:RENEW SOFTWOOD PARTING OR STAFF BEAD LM 9.49 Window:Renew softwood parting bead to box sash window

complete and decorate to match existing and remove waste and debris.

315019 R WINDOW:RENEW SET OF SASH CORDS IT 23.86 Window:Renew set of pulley cords complete including remove and

refix sliding sash pockets and beads and ease pulley (per sash).

Page 114: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

80 Local Space Housing

315021 R WINDOW:RENEW PULLEY WHEEL TO BOX SASH NO 33.31 Window:Renew sliding sash pulley wheel including remove and refix

sash and renew cords if required, touch up decorations to match existing and remove waste and debris.

315023 R WINDOW:RENEW SASH WEIGHT(S) TO BOX SASH NO 60.58 Box Sash:Renew weight(s) to sliding sash including remove and

refix sash and renew cords if required, touch up decorations to match existing and remove waste and debris.

315025 R WINDOW:RENEW SPIRAL BALANCES TO BOX SASH IT 105.47 Balance:Renew any type and size of spiral balances to double hung

sash unit including remove/refix sashes, beads, linings etc, renew balances, test and make good decorations to match existing and remove waste and debris.

315027 R WINDOW FRAME:CUT OUT AND SPLICE NEW SECTION LM 47.58 Frame:Cut out and splice in new section treated softwood frame

any size or profile to match existing, plugged to brick work and pointed with sealant, make good to plasterwork and decorate to match existing and remove waste and debris.

315029 R WINDOW CILL:CUT OUT AND SPLICE NEW NE 300MM IT 39.46 Cill:Cut out and splice in new section ne 300mm long any size or

profile of preservative hardwood cill to match existing frame, plugged to brickwork, and pointed with sealant, make good plasterwork and decorate to match existing and remove waste and debris.

315031 R WINDOW CILL:CUT OUT AND SPLICE NEW OVER 300MM LM 54.93 Cill:Cut out and splice in new section over 300mm long any size or

profile of preservative hardwood cill to match existing frame, plugged to brickwork, and pointed with sealant, make good plasterwork and decorate to match existing and remove waste and debris.

315035 R WINDOW:RENEW GLAZING BEAD LM 7.40 Window:Renew with 14x20mm preservative treated softwood or

hardwood glazing bead and decorate to match existing and remove waste and debris.

315039 R WINDOW:REFIX LOOSE GLAZING BEAD LM 5.86 Window:Refix loose glazing bead and bed in sealant. 315041 R WINDOW:RENEW CILL NOSING LM 16.15 Window:Renew front section of cill with any size or profile to match

existing with screws and pellated and bed in sealant including cut out defective section and shape new to match existing, redecorate to match existing and remove waste and debris.

315043 R WINDOW:RENEW GLAZING BAR LM 49.70 Window:Renew glazing bar, any size or profile to match existing,

reglaze with existing glass, splice new section, remove/refix sashes as required, redecorate to match existing (refixing of glass is Contractors risk).

315045 R WINDOW:RENEW WEATHER MOULD LM 7.52 Window:Renew weather or parrot mould, cut out old and fix new

mould, redecorate to match existing and remove waste and debris.

Page 115: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

81 Local Space Housing

315047 R WINDOW:REPAIR SASH RAIL OR STILE LM 55.32 Window:Repair sash rail or stile any size or profile to match

existing, reglaze with existing glass, splice new section, remove/refix fittings, redecorate to match existing (refixing of glass is Contractors risk).

315049 R WINDOW:OVERHAUL CASEMENT NO 39.35 Window:Overhaul timber casement window, dismantle as necessary

and subsequently reassemble including freeing, easing and adjusting casements to give correct operation, renew sealing gaskets, renew fixing screws, remove, refit or renew ironmongery as necessary, rake out and renew defective putty and mastic, touch up decorations externally and internally to match existing and remove waste and debris.

315051 R WINDOW:OVERHAUL SASH NO 48.08 Window:Overhaul timber sash window, renew staff and parting

beads, take out sashes and later rehang on appropriate sized new undyed plaited nylon sash cords, renew pocket pieces, wedge and cramp loose sash frames, oil pulleys, ease and adjust sashes, remove, refit or renew ironmongery, rake out and renew defective putty and mastic, touch up decorations externally and internally to match existing and remove waste and debris.

Timber Window Repairs - Compounds 315105 R TIMBER:EPOXY REPAIR NE 10MM:OVER 300MM LM 41.52 Timber:Repair decayed external joinery timber, carefully cut away

defective material, two part epoxy resin based filler/repair compound filling to joints, cracks, shakes, splits and the like, any width not exceeding 10mm, any depth, exceeding 300mm long all preparatory work and making good, preparation for redecoration.

315107 R TIMBER:EPOXY REPAIR NE 10MM:NE 300MM NO 29.16 Timber:Repair decayed external joinery timber, carefully cut away

defective material, two part epoxy resin based filler/repair compound filling to joints, cracks, shakes, splits and the like, any width not exceeding 10mm, any depth, not exceeding 300mm long all preparatory work and making good, preparation for redecoration.

315109 R TIMBER:EPOXY REPAIR NE 25MM:NE 300MM NO 37.85 Timber:Repair decayed external joinery timber, carefully cut away

defective material, two part epoxy resin based filler/repair compound filling to plain surfaces and the like, any width not exceeding 25mm, any depth, not exceeding 300mm long all preparatory work and making good, preparation for redecoration.

315111 R TIMBER:EPOXY REPAIR NE 50MM:NE 300MM NO 31.33 Timber:Repair decayed external joinery timber, carefully cut away

defective material, two part epoxy resin based filler/repair compound filling to plain surfaces and the like, any width exceeding 25mm but not exceeding 50mm, any depth, not exceeding 300mm long all preparatory work and making good, preparation for redecoration.

315113 R TIMBER:EPOXY REPAIR NE 75MM:NE 300MM NO 34.95 Timber:Repair decayed external joinery timber, carefully cut away

defective material, two part epoxy resin based filler/repair compound filling to plain surfaces and the like, any width exceeding 50mm but not exceeding 75mm, any depth not exceeding 300mm long all preparatory work and making good, preparation for redecoration.

Page 116: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

82 Local Space Housing

315115 R TIMBER:EPOXY REPAIR NE 25MM:NE 300MM NO 29.88 Timber:Repair decayed external joinery timber, carefully cut away

defective material, two part epoxy resin based filler/repair compound filling to irregular surfaces, mouldings and the like, any width not exceeding 25mm, any depth, not exceeding 300mm long all preparatory work and making good, preparation for redecoration.

315117 R TIMBER:EPOXY REPAIR NE 50MM:NE 300MM NO 36.40 Timber:Repair decayed external joinery timber, carefully cut away

defective material, two part epoxy resin based filler/repair compound filling to irregular surfaces, mouldings and the like, any width exceeding 25mm but not exceeding 50mm, any depth, not exceeding 300mm long all preparatory work and making good, preparation for redecoration.

315119 R TIMBER:EPOXY REPAIR NE 75MM:NE 300MM NO 37.85 Timber:Repair decayed external joinery timber, carefully cut away

defective material, two part epoxy resin based filler/repair compound filling to irregular surfaces, mouldings and the like, any width exceeding 50mm but not exceeding 75mm, any depth, not exceeding 300mm long all preparatory work and making good, preparation for redecoration.

Windows - Metal - Timber Sub-Frame 316209 R WINDOW:RENEW TIMBER SUB-FRAME TO METAL LM 28.89 Window:Renew timber sub-frame and cill to any steel window,

including take out existing metal window and set aside, remove sub- frame, prepare for and supply and fix preservative treated softwood frame and preservative treated hardwood cill to any size or profile to match existing suit window bedded in mortar and pointed with sealant refix steel window, make good to plasterwork and cill board and redecorate to match existing and remove waste and debris.

Windows - Metal - Repairs 316401 R WINDOW:EASE OIL BUTTS ADJUST ANY METAL NO 6.71 Window:Ease and oil butts to metal window including force open if

necessary, strip paint, file and grind edges.

316405 R WINDOW:RENEW WEATHER DRAUGHT PROOFING METAL IT 17.21 Window:Renew proprietary weather/draught proofing to any

opening light to metal window and adjust window as necessary to ensure effective operation.

316407 E WINDOW:OVERHAUL METAL NO 38.62 Window:Overhaul any type of metal window, dismantle as

necessary and subsequently reassemble including freeing, easing, oiling and adjusting casements to give correct operation, including file and grind edges, renew fixing screws, remove, refit or renew ironmongery as necessary, rake out and renew defective putty and mastic, touch up decorations internally to match existing and remove waste and debris.

Page 117: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

83 Local Space Housing

Windows - Aluminium - Repairs 317201 R WINDOW:EASE OIL BUTTS ADJUST ANY ALUMINIUM NO 8.01 Window:Ease and oil butts to any type of aluminium window

including renewing runners if necessary.

317205 E WINDOW:OVERHAUL ALUMINIUM NO 38.62 Window:Overhaul any type of aluminium window, dismantle as

necessary and subsequently reassemble including freeing, easing and adjusting casements to give correct operation, renew fixing screws, remove, refit or renew ironmongery as necessary, rake out and renew defective sealants and mastic, make good.

Windows - PVCu - Repairs 318101 R WINDOW:RENEW FANLIGHT PVCU SASH NO 47.23 Window:Renew any size and type of fanlight sash to PVCu window

including double glazing and all ironmongery and make good.

318103 R WINDOW:RENEW SIDE HUNG PVCU SASH NO 86.45 Window:Renew any size and type of sidehung sash to PVCu

window including double glazing and all ironmongery and make good.

318105 R WINDOW:RENEW TRICKLE VENT TO PVCU IT 11.16 Window:Renew or repair any trickle vent to PVCu window. 318107 R WINDOW:RENEW HANDLE TO PVCU NO 16.10 Window:Renew any defective or broken handle to PVCu window

including remove existing, check, lubricate operating mechanism, renew handle to match existing and test.

318108 R WINDOW:RENEW LOCKING HANDLE TO PVCU NO 20.88 Window:Renew any defective or broken locking handle to PVCu

window including remove existing, check, lubricate operating mechanism, renew handle to match existing and test.

318109 R WINDOW:RENEW HINGE TO PVCU NO 10.24 Window:Renew any defective or broken hinge to PVCu window

including remove existing and renew hinge to match existing and remove waste and debris.

318111 R WINDOW:RENEW ESPAGNOLETTE LOCK TO PVCU IT 21.94 Window:Renew any defective or broken espagnolette locking

mechanism to PVCu window including remove existing and renew to match existing and and test.

318113 R WINDOW:RENEW SEALING GASKET TO PVCU IT 7.17 Window:Renew sealing gasket to any opening light of PVCu window

(per opening light).

318115 R WINDOW:CHECK LUBRICATE FITTINGS TO PVCU IT 6.71 Window:Check operation of all fittings and operating mechanisms

to PVCu window complete including lubricate and adjust as necessary.

318117 E WINDOW:EASE AND ADJUST PVCU SASH IT 11.16 Window:Ease and adjust PVCu sash including realign as necessary.

Page 118: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

84 Local Space Housing

318119 E WINDOW:OVERHAUL TILT TURN MECHANISM TO PVCU NO 18.74 Window:Check operation of tilt and turn mechanism to PVCu

window including overhaul, lubricate and adjust as necessary.

318121 U WINDOW:RENEW TILT TURN MECHANISM TO PVCU NO 102.05 Window:Renew any tilt and turn mechanism complete to PVCu

window of any size to match existing, including remove existing, test and leave in proper working order and remove waste and debris.

318123 U WINDOW:CHILD RESTRICTOR TO PVCU NO 10.27 Window:Renew or supply and fix new adjustable child proof

restrictor/catch to any type of PVCu window including removing existing fitting.

318125 R WINDOW:OVERHAUL PVCU NO 38.62 Window:Overhaul any type of PVCu window, dismantle as

necessary and subsequently reassemble including freeing, easing and adjusting casements to give correct operation, renew fixing screws, remove, refit or renew ironmongery as necessary, check, lubricate operating mechanism, renew gaskets, make good and test.

318151 R WINDOW:RENEW GLAZING BEAD TO PVCU LM 6.13 Window:Renew any type of defective PVCu glazing bead including

remove existing bead, clean, prepare and supply and fit new bead to match existing including all cutting, mitres, sealing with silicone sealant as necessary

318155 R WINDOW:RENEW OPENER GASKET TO PVCU LM 2.49 Window:Renew gasket to any style of PVCu window opening light. 318157 R WINDOW:RENEW FRICTION STAY TO PVCU NO 8.58 Window:Renew any type of stay with stainless steel friction stay to

PVCu window.

318159 R WINDOW:RENEW RESTRAINING WEDGES TO PVCU NO 3.04 Window:Renew plastic restraining wedges to friction stay guide to

PVCu window.

318161 R WINDOW:RENEW RESTRICTOR STAY TO PVCU NO 10.27 Window:Renew restrictor stay to match existing to PVCu window. 318163 R WINDOW:RENEW LOCKING HANDLE TO PVCU NO 14.31 Window:Renew any type of window handle and striker plate with

‘Securistyle Empress’ locking plate to PVCu window.

318165 R WINDOW:RENEW DRIP MOULD BEAD TO PVCU LM 5.43 Window:Renew drip mould bead to PVCu window and make good. 318167 R WINDOW:PROVIDE DRIP MOULD BEAD TO PVCU LM 4.12 Window:Provide standard section PVCu drip mould bead, fix to

PVCu window and make good.

318169 R WINDOW:PROVIDE 30MM EXTENSION FLANGE TO PVCU LM 5.52 Window:Provide 30mm standard section PVCu extension flange, fix

to PVCu window and make good.

Page 119: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

85 Local Space Housing

318171 R WINDOW:PROVIDE 45MM EXTENSION FLANGE TO PVCU LM 5.80 Window:Provide 45mm standard section PVCu extension flange, fix

to PVCu window and make good.

318173 R WINDOW:PROVIDE 30MM BOX EXTENSION TO PVCU LM 5.52 Window:Provide 30mm PVCu box extension piece, fix to PVCu

window and make good.

318175 R WINDOW:PROVIDE 45MM BOX EXTENSION TO PVCU LM 5.80 Window:Provide 45mm PVCu box extension piece fix to PVCu

window and make good.

318177 R WINDOW:RENEW DRAIN CAPS TO PVCU IT 2.02 Window:Renew any missing or broken drain caps to PVCu window

(per window).

318179 R WINDOW:REPOINT SILICONE TO PVCU FRAME LM 3.97 Window:Rake out, prepare and repoint with silicone mastic sealant

complete around any external face of PVCu window frame.

318181 R WINDOW:RENEW QUADRANT FILLET TO PVCU LM 5.31 Window:Renew cellular PVCu quadrant cover fillet fixed with

approved adhesive or other approved concealed fixing method internally around windows make good plasterwork and decorations.

318185 R WINDOW:RENEW CILL TO PVCU LM 18.99 Window:Renew standard section PVCu cill to PVCu window, remove

existing cill, clean, prepare and supply and fit new cill to match existing including end caps, all cutting, mitres, sealing with silicone sealant as necessary and make good.

318187 R WINDOW:PROVIDE CILL TO PVCU LM 14.61 Window:Provide standard section PVCu cill to PVCu window clean,

prepare and supply and fit new cill including end caps all cutting, mitres, sealing with silicone sealant as necessary and make good.

318189 R WINDOW:RENEW CILL ENDS TO PVCU NO 2.33 Window:Renew any missing or broken cill ends to PVCu window

(per window).

Windows PVCu - Overhaul 318301 R WINDOWS/DOORS:PVCU 1 BED HOUSE CHECK CLEAN IT 42.29 Windows/doors:Check all PVCu windows and doors to 1 bed house or

maisonette, including freeing, easing, adjusting, realigning/ rehanging opening sashes/casements and doors, checking operation of all fittings and operating mechanisms, lubricating and adjusting as necessary to give correct operation, replace any missing fixings, recording any other defects requiring repair/replacement and provide written report to Client Representative, clean all surfaces/profiles externally using proprietary cleaner, wash and dry off.

318303 R WINDOWS/DOORS:PVCU 2 BED HOUSE CHECK CLEAN IT 53.95 Windows/doors:Check all PVCu windows and doors to 2 bed house or

maisonette, including freeing, easing, adjusting, realigning/ rehanging opening sashes/casements and doors, checking operation of all fittings and operating mechanisms, lubricating and adjusting as necessary to give correct operation, replace any missing fixings, recording any other defects requiring repair/replacement and provide written report to Client Representative, clean all surfaces/profiles externally using proprietary cleaner, wash and dry off.

Page 120: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

86 Local Space Housing

318305 R WINDOWS/DOORS:PVCU 3 BED HOUSE CHECK CLEAN IT 60.95 Windows/doors:Check all PVCu windows and doors to 3 bed house or

maisonette, including freeing, easing, adjusting, realigning/ rehanging opening sashes/casements and doors, checking operation of all fittings and operating mechanisms, lubricating and adjusting as necessary to give correct operation, replace any missing fixings, recording any other defects requiring repair/replacement and provide written report to Client Representative, clean all surfaces/profiles externally using proprietary cleaner, wash and dry off.

318307 R WINDOWS/DOORS:PVCU 4 BED HOUSE CHECK CLEAN IT 70.43 Windows/doors:Check all PVCu windows and doors to 4 bed house or

maisonette, including freeing, easing, adjusting, realigning/ rehanging opening sashes/casements and doors, checking operation of all fittings and operating mechanisms, lubricating and adjusting as necessary to give correct operation, replace any missing fixings, recording any other defects requiring repair/replacement and provide written report to Client Representative, clean all surfaces/profiles externally using proprietary cleaner, wash and dry off.

318309 R WINDOWS/DOORS:PVCU 5 BED HOUSE CHECK CLEAN IT 77.43 Windows/doors:Check all PVCu windows and doors to 5 bed house or

maisonette, including freeing, easing, adjusting, realigning/ rehanging opening sashes/casements and doors, checking operation of all fittings and operating mechanisms, lubricating and adjusting as necessary to give correct operation, replace any missing fixings, recording any other defects requiring repair/replacement and provide written report to Client Representative, clean all surfaces/profiles externally using proprietary cleaner, wash and dry off.

318311 R WINDOWS/DOORS:PVCU 1 BED FLAT CHECK CLEAN IT 33.83 Windows/doors:Check all PVCu windows and doors to 1 bed flat or

bungalow, including freeing, easing, adjusting, realigning/ rehanging opening sashes/casements and doors, checking operation of all fittings and operating mechanisms, lubricating and adjusting as necessary to give correct operation, replace any missing fixings, recording any other defects requiring repair/replacement and provide written report to Client Representative, clean all surfaces/profiles externally using proprietary cleaner, wash and dry off.

318313 R WINDOWS/DOORS:PVCU 2 BED FLAT CHECK CLEAN IT 37.55 Windows/doors:Check all PVCu windows and doors to 2 bed flat or

bungalow, including freeing, easing, adjusting, realigning/ rehanging opening sashes/casements and doors, checking operation of all fittings and operating mechanisms, lubricating and adjusting as necessary to give correct operation, replace any missing fixings, recording any other defects requiring repair/replacement and provide written report to Client Representative, clean all surfaces/profiles externally using proprietary cleaner, wash and dry off.

318315 R WINDOWS/DOORS:PVCU 3 BED FLAT CHECK CLEAN IT 51.62 Windows/doors:Check all PVCu windows and doors to 3 bed flat or

bungalow, including freeing, easing, adjusting, realigning/ rehanging opening sashes/casements and doors, checking operation of all fittings and operating mechanisms, lubricating and adjusting as necessary to give correct operation, replace any missing fixings, recording any other defects requiring repair/replacement and provide written report to Client Representative, clean all surfaces/profiles externally using proprietary cleaner, wash and dry off.

Page 121: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

87 Local Space Housing

318317 R WINDOWS/DOORS:PVCU 4 BED FLAT CHECK CLEAN IT 63.43 Windows/doors:Check all PVCu windows and doors to 4 bed flat or

bungalow, including freeing, easing, adjusting, realigning/ rehanging opening sashes/casements and doors, checking operation of all fittings and operating mechanisms, lubricating and adjusting as necessary to give correct operation, replace any missing fixings, recording any other defects requiring repair/replacement and provide written report to Client Representative, clean all surfaces/profiles externally using proprietary cleaner, wash and dry off.

318319 R WINDOWS/DOORS:PVCU 5 BED FLAT CHECK CLEAN IT 65.91 Windows/doors:Check all PVCu windows and doors to 5 bed flat or

bungalow, including freeing, easing, adjusting, realigning/ rehanging opening sashes/casements and doors, checking operation of all fittings and operating mechanisms, lubricating and adjusting as necessary to give correct operation, replace any missing fixings, recording any other defects requiring repair/replacement and provide written report to Client Representative, clean all surfaces/profiles externally using proprietary cleaner, wash and dry off.

Windows and Door Frames - Silicone Pointing 318201 R DOOR FRAME:RAKE OUT AND REPOINT SEALANT IT 14.23 Door Frame:Rake out, prepare and repoint with silicone mastic

sealant complete around any door frame of any size (per face).

318203 R WINDOW FRAME:RAKE OUT AND REPOINT IT 15.12 Window Frame:Rake out, prepare and repoint with silicone mastic

sealant complete around any window frame (per face).

318207 R WINDOW FRAME:PROVIDE AND FIX BEAD OR SEALANT IT 21.24 Window Frame:Provide and fix suitable size PVCu quadrant or

flexible PVC cover trim fixed with silicone mastic sealant to form a neat clean beaded surround, to jambs and head of any window frame, any location internally and ne 2 storeys externally. Including raking out existing defective sealant, hacking back plaster or render as necessary, cleaning and notching new quadrant/trim around all obstructions (per face).

Windows - Roof 319001 R ROOF WINDOW:RENEW NE 0.78X0.98M NO 618.92 Roof Window:Renew roof window complete size ne 0.78x0.98m

with Velux aluminium clad externally roof window with factory fitted clear float double glazed sealed unit, all upstands, flashings and dressing of flashings, fixing to timber with screws and make good all finishings internally and roof coverings externally, and remove waste and debris.

319003 R ROOF WINDOW:RENEW NE 1.14X1.18M NO 704.83 Roof Window:Renew roof window complete size ne 1.14x1.18m

with Velux aluminium clad externally roof window with factory fitted clear float double glazed sealed unit, all upstands, flashings and dressing of flashings, fixing to timber with screws and make good all finishings internally and roof coverings externally, and remove waste and debris.

Page 122: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

88 Local Space Housing

319005 R ROOF WINDOW:RENEW NE 1.34X1.40M NO 794.62 Roof Window:Renew roof window complete size ne 1.34x1.40m

with Velux aluminium clad externally roof window with factory fitted clear float double glazed sealed unit, all upstands, flashings and dressing of flashings, fixing to timber with screws and make good all finishings internally and roof coverings externally, and remove waste and debris.

Windows - Roof - Repairs 319101 U ROOF WINDOW:REMEDY LEAK OR REDRESS FLASHINGS NO 31.32 Roof Window:Redress roof flashings around roof window and reseal

to prevent water penetration.

319103 R ROOF WINDOW:OVERHAUL OPENING GEAR NO 28.43 Roof Window:Overhaul opening gear to any type of roof window. 319105 R ROOF WINDOW:RENEW CONTROL CORDS NO 28.37 Roof Window:Renew operating control cords to any roof window. External Doors Doors - External Panelled or Glazed - Hardwood - Standard 321105 R DOOR:RENEW HW PANELLED OR GLAZED BACK DOOR NO 450.52 Door:Renew back door with any size 44mm hardwood panelled,

glazed or part glazed door prepared for glazing, hang on 1.5 pair butts, fix new mortice lock, furniture, keep, pair of bolts, hardwood weathermould, adjust stops and ease rebates, cut out and make good to frame to suit new position of hinges, weathermould and lock, rebate door bottom as necessary and fit new water bar if required, double glazed and decorate to match existing and remove waste and debris.

321107 R DOOR:RENEW HW PANELLED OR GLAZED FRONT DOOR NO 582.94 Door:Renew front door with any size 44mm hardwood panelled,

glazed or part glazed door prepared for glazing, hang on 1.5 pair butts, fix new mortice lock, furniture, keep, pair of bolts, cylinder latch and pull, security restraint device, letter plate including cutting mortice in door to suit, numerals, hardwood weathermould, adjust stops, ease rebates, cut out and make good to frame to suit new position of butts, weathermould, lock and latch, rebate door bottom as necessary and fit new waterbar if required, double glazed and decorate to match existing and remove waste and debris.

Doors - External Panelled or Glazed - Hardwood - Purpose

Made

321305 R DOOR:RENEW PM HW PANELLED OR GLAZED BACK DOOR NO 693.67 Door:Renew back door with any size 44mm hardwood panelled,

glazed or part glazed purpose made door prepared for glazing, hang on 1.5 pair butts, fix new mortice lock, furniture, keep, pair of bolts, hardwood weathermould, adjust stops and ease rebates, cut out and make good to frame to suit new position of hinges, weathermould and rebate door bottom as necessary and fit new water bar if required, double glazed and decorate to match existing and remove waste and debris.

Page 123: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

89 Local Space Housing

321307 R DOOR:RENEW PM HW PANELLED OR GLAZED FRONT DOOR NO 826.08 Door:Renew front door with any size 44mm hardwood panelled,

glazed or part glazed purpose made door prepared for glazing, hang on 1.5 pair butts, fix new mortice lock, furniture, keep, pair of bolts, cylinder latch and pull, security restraint device, letter plate including cutting mortice in door to suit, numerals, hardwood weathermould, adjust stops, ease rebates, cut out and make good to frame to suit new position of butts, weathermould, lock and latch, rebate door bottom as necessary and fit new waterbar if required, double glazed and decorate to match existing and remove waste and debris.

Doors - External Panelled or Glazed - Softwood - Standard 321505 R DOOR:RENEW SW PANELLED OR GLAZED BACK DOOR NO 381.64 Door:Renew back door with any size 44mm softwood panelled,

glazed or part glazed door prepared for glazing, hang on 1.5 pair butts, fix new mortice lock, furniture, keep, pair of bolts, softwood weathermould, adjust stops and ease rebates, cut out and make good to frame to suit new position of hinges, weathermould and lock, rebate door bottom as necessary and fit new water bar if required, double glazed and decorate to match existing and remove waste and debris.

321507 R DOOR:RENEW SW PANELLED OR GLAZED FRONT DOOR NO 509.67 Door:Renew front door with any size 44mm softwood panelled,

glazed or part glazed door prepared for glazing, hang on 1.5 pair butts, fix new mortice lock, furniture, keep, pair of bolts, cylinder latch and pull, security restraint device, letter plate including cutting mortice in door to suit, numerals, softwood weathermould, adjust stops, ease rebates, cut out and make good to frame to suit new position of butts, weathermould, lock and latch, rebate door bottom as necessary and fit new waterbar if required, double glazed and decorate to match existing and remove waste and debris.

Doors - External Panelled or Glazed - Softwood - Purpose

Made

321705 R DOOR:RENEW PM SW PANELLED OR GLAZED BACK DOOR NO 616.98 Door:Renew back door with any size 44mm softwood panelled,

glazed or part glazed purpose made door prepared for glazing, hang on 1.5 pair butts, fix new mortice lock, furniture, keep, pair of bolts, softwood weathermould, adjust stops and ease rebates, cut out and make good to frame to suit new position of hinges, weathermould and rebate door bottom as necessary and fit new water bar if required, double glazed and decorate to match existing and remove waste and debris.

321707 R DOOR:RENEW PM SW PANELLED OR GLAZED FRONT DOOR NO 740.64 Door:Renew front door with any size 44mm softwood panelled,

glazed or part glazed purpose made door prepared for glazing, hang on 1.5 pair butts, fix new mortice lock, furniture, keep, pair of bolts, cylinder latch and pull, security restraint device, letter plate including cutting mortice in door to suit, numerals, softwood weathermould, adjust stops, ease rebates, cut out and make good to frame to suit new position of butts, weathermould, lock and latch, rebate door bottom as necessary and fit new waterbar if required, double glazed and decorate to match existing and remove waste and debris.

Page 124: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

90 Local Space Housing

Doors - External - High Performance 322101 R DOOR:HIGH PERFORMANCE BACK DOOR NO 548.95 Door:Renew back door with any size proprietary high performance

door or similar prefinished and preglazed, hang on 1.5 pair butts, fix new mortice lock, door furniture, keeps, pair of bolts, proprietary weathermould, adjust stops and ease rebates, cut out and make good to frame to suit new position of hinges, weathermould and lock, rebate door bottom as necessary and fit new water bar if required, touch up decorations to match existing and remove waste and debris.

322103 R DOOR:HIGH PERFORMANCE FRONT DOOR NO 659.04 Door:Renew front door with any size proprietary high performance

door or similar prefinished and preglazed, hang on 1.5 pair butts, fix new mortice lock, door furniture, keeps, pair of bolts, cylinder nightlatch and pull, security restraint device, proprietary letter plate including cutting mortice in door to suit, numerals, proprietary weathermould, adjust stops and ease rebates, cut out and make good to frame to suit new position of butts, weathermould, lock and lock, rebate door bottom as necessary and fit new new waterbar if required, touch up decorations to match existing and remove waste and debris.

Doors - External - Firecheck Flush 323101 R DOOR:RENEW 1/2HR FLUSH FRONT DOOR NO 428.92 Door:Renew front door with any size 0.50hr flush firecheck door

and hang on 1.5 pair butts, fix new mortice lock, furniture and keep, pair bolts, cylinder latch and pull, security restraint device letter plate including cutting/adapting mortice in door to suit, numerals, fix new weathermould, adjust stops, ease rebates, fix intumescent strips seals etc., cut out and make good to frame to suit new position of butts, weathermould, lock and latch, rebate door bottom as necessary and fit new waterbar if required and decorate to match existing and remove waste and debris.

323103 R DOOR:RENEW 1HR FLUSH FRONT DOOR NO 526.34 Door:Renew front door with any size 1.00hr flush firecheck door

and ang on 1.5 pair butts, fix new mortice lock, furniture and keep, pair bolts, cylinder latch and pull, security restraint device letter plate including cutting/adapting mortice in door to suit, numerals, fix new weathermould, adjust stops, ease rebates, fix intumescent strips, seals etc., cut out and make good to frame to suit new position of butts, weathermould, lock and latch, rebate door bottom as necessary and fit new waterbar if required and decorate to match existing and remove waste and debris.

323105 R DOOR:RENEW 1/2HR FLUSH COMMUNAL DOOR NO 303.74 Door:Renew communal door with any size 0.50hr flush firecheck

door and hang on 1.5 pair butts, fix new mortice dead lock, furniture and keep, door closer, including cutting/adapting mortice in door to suit, fix new weathermould, adjust stops, ease rebates, fix intumescent strips seals etc., cut out and make good to frame to suit new position of butts, weathermould, lock, rebate door bottom as necessary and fit new waterbar if required and decorate to match existing and remove waste and debris.

Page 125: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

91 Local Space Housing

323107 R DOOR:RENEW 1HR FLUSH COMMUNAL DOOR NO 361.11 Door:Renew communal door with any size 1.00hr flush firecheck

door and hang on 1.5 pair butts, fix new firecheck door and hang on 1.5 pair butts, fix new mortice dead lock, furniture and keep, door closer, including cutting/adapting mortice in door to suit, fix new weathermould, adjust stops, ease rebates, fix intumescent strips seals etc., cut out and make good to frame to suit new position of butts, weathermould, lock, rebate door bottom as necessary and fit new waterbar if required and decorate to match existing and remove waste and debris.

Doors - External Matchboard - Softwood 328101 R DOOR:RENEW L AND B DOOR NO 230.57 Door:Renew external door with any size 40mm thick single

softwood matchboard ledged and braced door with 169x20mm ledges and 106x20mm braces covered on face with 20mm tongued, grooved and v jointed boarding, including remove existing door and hinges, remove and refit door stop as necessary, fit and hang new door on one pair of hinges, make good frame, complete with all ironmongery and decorate to match existing and remove waste and debris.

328103 R DOOR:RENEW FL AND B DOOR NO 248.10 Door:Renew external door with any size 40mm thick single

softwood matchboard framed, ledged and braced door with 169x20mm ledges and 106x20mm braces covered on face with 20mm tongued, grooved and v jointed boarding, including remove existing door and hinges, remove and refit door stop as necessary, fit and hang new door on one pair of hinges, make good frame, complete with all ironmongery and decorate to match existing and remove waste and debris.

Doors - External - PVCu Residential Type 323501 R DOOR:RENEW PVCU PANELLED GLAZED DOOR AND FRAME NO 560.31 Door:Renew any type door and frame with any size PVCu panelled/

half glazed door, double glazed internally with 20mm thick hermetically sealed unit, PVCu frame, prehung, complete with multipoint locking system, handles, threshold and integral weather seals, remove existing and fix new to prepared opening using cleats or screw bolts, seal around externally with flexible foam strip and silicone sealant, make good all finishes internally and externally.

323503 R DOOR:RENEW PVCU 2 PANEL DOOR AND FRAME NO 642.23 Door:Renew any type door and frame with any size PVCu two

panel/half glazed door, double glazed internally with 20mm thick hermetically sealed unit, PVCu frame, prehung, complete with multipoint locking system, handles, threshold and integral weather seals, remove existing and fix new to prepared opening using cleats or screw bolts, seal around externally with flexible foam strip and silicone sealant, make good all finishes internally and externally.

323505 R DOOR:RENEW PVCU PANELLED GLAZED DOOR NO 462.69 Door:Renew any door with any size PVCu panelled/half glazed door,

double glazed internally with 20mm thick hermetically sealed unit hanging to existing PVCu frame on new hinges, complete with multi- point locking system, handles, threshold and integral weather seals, remove existing door and clear away, make good all finishes internally and externally.

Page 126: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

92 Local Space Housing

323507 R DOOR:RENEW PVCU 2 PANEL DOOR NO 462.69 Door:Renew any door with any size PVCu two panel/half glazed

door, double glazed internally with 20mm thick hermetically sealed unit hanging to existing PVCu frame on new hinges, complete with multi- point locking system, handles, threshold and integral weather seals, remove existing door and clear away, make good all finishes internally and externally.

323509 R DOOR:RENEW PVCU TILT AND TURN FRENCH DOOR IT 1413.27 DOOR:Renew any type door and frame with pair of any size ne

5.00sm PVCu french tilt/turn door, double glazed internally 20mm thick, hermetically sealed unit, PVCu frame, prehung, complete with multi- point locking system, handles, threshold and integral weather seals, remove existing and fix new to prepared opening using cleats or screw bolts, seal around externally with flexible foam strip and silicone sealant, make good all finishes internally and externally.

Doors - External - High Performance PVCu Residential Type 323601 R DOOR:HIGH PERFORMANCE PVCU BACK DOOR NO 576.92 Door:Renew back door with any size panelled, glazed or partially

glazed or similar proprietary high performance PVCu door, prefinished and preglazed, hang on 1.5 pair butts, fix new mortice lock, door furniture, keeps, pair of bolts, proprietary weathermould, adjust stops and ease rebates, cut out and make good to frame to suit new position of hinges, weathermould and lock, rebate door bottom as necessary and fit new water bar if required, and remove waste and debris.

323603 R DOOR:HIGH PERFORMANCE PVCU FRONT DOOR NO 666.59 Door:Renew front door with any size panelled, glazed or partially

glazed or similar proprietary high performance PVCu door, prefinished and preglazed, hang on 1.5 pair butts, fix new mortice lock, door furniture, keeps, pair of bolts, cylinder nightlatch and pull, security restraint device, proprietary letter plate including cutting mortice in door to suit, numerals, proprietary weathermould, adjust stops and ease rebates, cut out and make good to frame to suit new position of butts, weathermould, lock and lock, rebate door bottom as necessary and fit new waterbar if required, and remove waste and debris.

Doors - External - Repairs - Timber 324101 R DOOR:EASE ADJUST INCLUDING REMOVE NO 13.56 Door:Ease and adjust door, hung on upto 1.5 pairs of butt hinges,

including remove and rehang door as necessary and make good to butt recesses to frame and touch up decorations, and remove waste and debris.

324107 R DOOR:REFIX LOOSE GLAZING BEADS NO 7.74 Door:Refix loose glazing beads to door including bedding and

sealing with sealant (per door).

324109 R DOOR:RENEW PLYWOOD PANEL NO 28.78 Door:Renew 9mm external quality plywood panel size 610x610mm

to door, including remove weatherseal, refix or renew beads, renew weatherseal and decorate to match existing and remove waste and debris.

Page 127: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

93 Local Space Housing

324111 R DOOR:PATCH OR REPAIR DOOR STILE NO 28.81 Door:Patch, repair hanging or closing stile of softwood door

including cut out and splice in new timber upto 600mm long, and decorate to match existing and remove waste and debris.

324113 R DOOR:RENEW SOFTWOOD DOOR STILE IT 66.08 Door:Renew closing stile to softwood door, remove glass or

plywood panels and beads and set aside, take down door and remove hinges, remove ironmongery and set aside, cut out defective stile to top, and bottom rails, refix glass or plywood panels and beads, refix ironmongery, ease and adjust door, and decorate to match existing and remove waste and debris.

324115 R DOOR:SUPPLY AND FIX WEATHERBOARD NO 18.13 Door:Supply and fix preservative treated redwood weatherboard to

door, bedded and pointed in sealant, cut out base of door frame to accommodate weatherboard and decorate to match existing and remove waste and debris.

324117 R DOOR:PROVIDE HARDWOOD RAIN DEFLECTOR NO 14.03 Door:Supply and fix 50x19mm hardwood bevelled rain deflector

with neoprene or rubber flexible pad at bottom, bedded in sealant and screwed to face of door.

324119 R DOOR:RENEW HARDWOODGLAZING BEADS LM 8.97 Door:Renew with preservative treated hardwood rebated splayed

and twice rounded glazing beads of any size and of any profile including mitres and ends to door, bedding and pointing with sealant and decorate to match existing and remove waste and debris.

324121 R DOOR:RENEW HARDWOOD DOOR STILE IT 105.59 Door:Renew closing stile to hardwood door, remove glass or

plywood panels and beads and set aside, take down door and remove hinges, remove ironmongery and set aside, cut out defective stile to top, middle and bottom rails, refix glass or plywood panels and beads, refix ironmongery, ease and adjust door, and decorate to match existing and remove waste and debris.

324123 R DOOR:OVERHAUL EXTERNAL COMPLETE NO 87.47 Door:Overhaul external door and frame complete, remove all iron-

mongery, piece out door, frame and architraves where ironmongery removed make good any damage, defects to timber, resecure architraves if loose, rehang door on one and a half pair of butt hinges, ease and adjust, touch up decorations to match existing and remove waste and debris.

324125 R DOOR:OVERHAUL EXTERNAL COMPLETE FANLIGHT NO 111.82 Door:Overhaul external door and frame with fanlight complete,

remove all ironmongery, piece out door, frame, and architraves where iron- mongery removed make good any damage, defects to timber, resecure glazing beads, and architraves if loose, rehang door on one and a half pair of butt hinges, ease and adjust, reglaze fanlight as necessary to BS 6262, touch up decorations to match existing and remove waste and debris.

328105 R DOOR:RENEW BOARD TO LEDGED AND BRACED DOOR IT 22.49 Door:Renew 114x25mm preservative treated softwood tongued and

grooved board to ledged and braced door and decorate to match existing and remove waste and debris.

Page 128: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

94 Local Space Housing

328107 R DOOR:RENEW LEDGE OR BRACE TO DOOR IT 13.85 Door:Renew 105x20mm preservative treated softwood ledge or

brace to ledged and braced door, and decorate to match existing and remove waste and debris.

Doors - External - Repairs - PVCu 325101 R DOOR:RENEW ANY BUTT HINGE TO PVCU NO 13.51 Door:Renew any butt hinge to PVCu door. 325103 E DOOR:OVERHAUL MULTIPOINT LOCK TO PVCU IT 11.30 Door:Overhaul and lubricate multipoint locking system to PVCu

door.

325105 U DOOR:RENEW MULTIPOINT LOCK TO PVCU NO 107.36 Door:Renew any defective or broken multipoint door locking system

complete to PVCu door, adapt keep if necessary, including remove existing, test and leave in working proper working order and remove waste and debris.

325107 U DOOR:ADJUST LOCK TO PVCU NO 26.33 Door:Carefully remove existing PVCu door lock, ease and adjust

door in order to ensure correct working, refix existing lock.

325109 U DOOR:RENEW LOCK CYLINDER TO PVCU NO 32.28 Door:Renew any type of lock cylinder to PVCu door including

drilling out old cylinder, replacing with new matching cylinder complete with 2 No. keys, make good, test and leave in proper working order and remove waste and debris.

325111 U DOOR:RENEW LOCK CATCH OR KEEP TO PVCU NO 13.93 Door:Renew any door catch or keep to PVCu door including all

adjustment and making good necessary.

325113 U DOOR:REPAIR HANDLES TO PVCU NO 14.58 Door:Repair any type of door handle to PVCu door including

carefully removing and refixing as necessary and making good.

325115 U DOOR:RENEW HANDLES TO PVCU NO 65.40 Door:Carefully remove existing pair of lever handles and plates and

remove from site, provide and fix new set of lever handles and plates to PVCu door (per set).

325117 U DOOR:OVERHAUL PVCU NO 43.65 Door:Overhaul any PVCu or glazed PVCu door, including remove

door from frame, ease and adjust foot of door, adjust door locking mechanisms and hinges to ensure that door operates correctly, rehang door to existing frame.

325123 U DOOR:RENEW PANEL NE 0.5SM TO PVCU NO 87.08 Door:Supply and fix composite insulated panel PVCu faced both

sides to PVCu door, fixed with and including matching PVCu trim and beading, carefully remove existing defective and redundant panel or glazing and making good, any size ne 0.50sm and remove waste and debris..

Page 129: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

95 Local Space Housing

325125 U DOOR:RENEW PANEL 0.5-1.0SM TO PVCU NO 126.50 Door:Supply and fix composite insulated panel PVCu faced both

sides to PVCu door, fixed with and including matching PVCu trim and beading. carefully remove existing defective and redundant panel or glazing and making good, any size over 0.50sm and ne 1.00sm and remove waste and debris..

Doors - External - Galvanised Steel (Crittall Type) 326105 R DOOR:EASE OIL AND ADJUST STEEL NO 13.27 Door:Ease including force open if necessary, strip paint, file and

grind edges, ease and oil hinges to steel door.

326107 R DOOR:RENEW LOCK TO STEEL NO 71.07 Door:Renew lock to any Crittall type of steel door including remove

existing and fix new, make all necessary adjustments to door frame, make good decorations and provide 2 No. keys and remove waste and debris.

Doors - External - Aluminium 327101 R DOOR:EASE OIL AND ADJUST ALUMINIUM NO 8.90 Door:Ease including force open if necessary, strip paint, file and

grind edges, ease and oil hinges to aluminium door.

327103 U DOOR:RENEW LOCK TO ALUMINIUM NO 71.07 Door:Renew lock to any type of aluminium door including remove

existing and fix new, make all necessary adjustments to door and frame, make good decorations and provide 2 No. keys and remove waste and debris.

327105 R PATIO DOOR:RENEW DOUBLE GLAZED ALUMINIUM DOOR NO 1625.16 Patio Door:Renew any glazed doors and frame, with polyester

powder coated aluminium external glazed patio doors and frame, including double glazing internally with 20mm thick hermetically sealed safety glass unit, frame built into opening, complete with mortice lock and keep and new bolts including making good.

Internal Timber Doors Doors - Internal - Flush 330001 R DOOR:RENEW INTERNAL PLY FLUSH NO 125.55 Door:Renew internal door with any size ne 40mm thick single

skeleton core flush door with 3.2mm luan, white Meranti or other approved plywood facing both sides and 9mm hardwood lipping on long edges, including remove existing door and hinges, remove and refit door stops as necessary, fit and hang new door on one pair of 100mm steel butt hinges, make good or alter butt recesses on frame, door complete with all ironmongery, make good and prepare to decorate and remove waste and debris.

330003 R DOOR:RENEW INTERNAL HARDBOARD FACED NO 108.42 Door:Renew internal door with any size ne 40mm thick single

skeleton core hardboard faced both sides flush internal door with hardwood lipping on long edges including remove existing door and hinges, remove and refit door stops as necessary, fit and hang new door on one pair of 100mm steel butt hinges, make good or alter butt recesses on frame, door complete with all ironmongery, make good and prepare to decorate and remove waste and debris.

Page 130: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

96 Local Space Housing

330005 R DOOR:RENEW INTERNAL EMBOSSED PANELLED NO 129.88 Door:Renew internal door with any size ne 40mm thick single

embossed hardboard panelled door including remove existing door and hinges, remove and refit door stops as necessary, fit and hang new door on one pair of 100mm steel butt hinges, make good or alter butt recesses on frame, door complete with all ironmongery, make good and prepare to decorate and remove waste and debris.

330011 R DOOR:RENEW INTERNAL HARDWOOD VENEERED NO 120.65 Door:Renew internal door with any size ne 40mm thick hardwood

veneered door including remove existing door and hinges, remove and refit door stops as necessary, fit and hang new door on one pair of 100mm steel butt hinges, make good or alter butt recesses on frame, door complete with glass and all ironmongery, make good and prepare to decorate and remove waste and debris.

330019 R DOOR:SUPPLY AND FIX SLIDING DOOR GEAR NO 44.22 Door:Supply and fix sliding door gear for hanging of any internal

door.

330021 R DOOR:CUT OPENINGS/SUPPLY AND FIX 225X75MM VENTS IT 12.51 Door:Cut opening in solid or hollow core door for 225x75mm

aluminium louvre ventilators and screw fix new ventilators to both faces of door.

Doors - Internal - Framed 330007 R DOOR:RENEW INTERNAL SOFTWOOD GLAZED NO 286.31 Door:Renew internal door with any size ne 40mm thick framed

softwood glazed door including remove existing door and hinges, remove and refix door stops as necessary, fit and hang new door on 1.5 pair of 100mm steel butt hinges, make good or alter butt recesses on frame, door complete with glazing and all ironmongery, make good and prepare to decorate and remove waste and debris.

330009 R DOOR:RENEW INTERNAL HARDWOOD GLAZED NO 428.06 Door:Renew internal door with any size ne 40mm thick framed

hardwood glazed door including remove existing door and hinges, remove and refit door stops as necessary, fit and hang new door on 1.5 pairs of 100mm steel butt hinges, make good or alter butt recesses on frame, door complete with glazing and all ironmongery, make good and prepare to decorate and remove waste and debris.

Doors - Internal – Firecheck 330013 R DOOR:RENEW 1/2HR FIRE INTERNAL NO 179.07 Door:Renew internal door with any size single half-hour fire check

flush door having 3.2mm luan, white Meranti or other approved plywood facing both sides and 9mm hardwood lipping on long edges, including remove existing door and hinges, remove and refit door stops as necessary, fit and hang new door on 1.5 pairs of 100mm steel butt hinges, make good or alter recesses on frame, door complete with all ironmongery, intumescent strips and smoke seals, prepare to decorate and remove waste and debris.

Page 131: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

97 Local Space Housing

330015 R DOOR:RENEW 1HR FIRE INTERNAL NO 298.80 Door:Renew internal door with any size single one-hour fire check

flush door having 3.2mm luan, white Meranti or other approved plywood facing both sides and 9mm hardwood lipping on long edges, including remove existing door and hinges, remove and refit door stops as necessary, fit and hang new door on 1.50 pairs of 100mm steel butt hinges, make good or alter recesses on frame, door complete with all ironmongery, intumescent strips and smoke seals, prepare to decorate and remove waste and debris.

330017 R DOOR:RENEW 1/2HR GLAZED FIRE INTERNAL NO 226.43 Door:Renew internal door with any size single half-hour fire check

glazed door having 3.2mm luan, white Meranti or other approved plywood facing both sides and 9mm hardwood lipping on long edges, including remove existing door and hinges, remove and refit door stops as necessary, fit and hang new door on 1.50 pairs of 100mm steel butt hinges, make good or alter recesses on frame, door complete with all ironmongery, intumescent strips and smoke seals, glazed and prepare to decorate and remove waste and debris.

330023 R DOOR:FORM VISION PANEL TO INTERNAL NO 63.50 Door:Cut opening approx 500x500mm in flush door and form vision

panel, glazed in laminated safety glass, bedded in washleather strip with minimum 15mm chamfered beads fixed with brass cups and screws and decorate.

Doors - Internal - Repairs - Timber 335003 R DOOR:EASE ADJUST REHANG INTERNAL NEW BUTTS NO 28.46 Door:Ease, reduce if required and adjust internal door including

take off and rehang on new butts, adjust stops or ease rebates, make good to door and lining as necessary and touch up paintwork to match existing.

335005 R DOOR:PATCH REPAIR INTERNAL IT 43.80 Door:Patch in and make good as necessary patch in softwood or

hardwood door, touch up decorations to match existing.

335009 R DOOR:RENEW STILE OR RAIL INTERNAL IT 52.95 Door:Renew any rail or stile to any type of softwood door including

remove and rehang door, remove and refix hinges, locks, furniture and the like in order to effect repairs and decorate to match existing.

335011 R DOOR:RENEW HARDWOOD EDGING STRIPS INTERNAL IT 34.10 Door:Renew hardwood edging strips to any door glued and pinned

to existing door including remove and rehang door, adjust stops/ease rebates, remove and refix ironmongery and redecorate to match existing.

335091 R DOOR:OVERHAUL INTERNAL COMPLETE NO 35.72 Door:Overhaul internal door and frame/lining complete, remove all iron

mongery, piece out door, frame and architraves where ironmongery removed and not being refixed, make good any damage, defects to timber, resecure architraves if loose, rehang door on one and a half pair of butt hinges, refix ironmongery, ease and adjust, touch up decorations to match existing and remove suplus spoil.

Page 132: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

98 Local Space Housing

Door Frames and Linings Door Frames - External - Timber 341101 R FRAME:RENEW EXTERNAL DOOR COMPLETE NO 166.48 Frame:Renew external door frame with rebated softwood door

frame to suit any size single door, remove existing door and set aside, take out existing frame and bed new frame in cement mortar, plugged and screwed to brickwork and pointed with sealant, rehang door, ease and adjust, refix lock keep including housing out, make good all works disturbed including refix or renew any internal beads, architraves etc. and decorate to match existing internally and externally and remove waste and debris.

341103 R FRAME:RENEW EXTERNAL DOOR WITH CILL COMPLETE NO 172.58 Frame:Renew external door frame with rebated softwood door

frame with cill to suit any size single door, remove existing door and set aside, take out existing frame and bed new frame in cement mortar, plugged and screwed to brickwork and pointed with sealant, rehang door including ease and adjust, refix lock keep including housing out, make make good all works disturbed including refix or renew any internal beads, architraves etc. and decorate to match existing internally and externally and remove waste and debris.

341105 R FRAME:RENEW EXTERNAL DOOR FANLIGHT COMPLETE NO 261.91 Frame:Renew external door frame with softwood door frame,

rebated and with fanlight over, to suit any size single door, remove existing door and set aside, remove existing frame and bed new frame in mortar, plugged and screwed to brickwork and point with sealant, rehang door including ease and adjust, refix lock keep including housing out, make good all works disturbed including refix or renew internal beads, architraves etc., double glaze to fanlight and decorate to match existing internally and externally and remove waste and debris.

Door Frames - External - High Performance 341201 R FRAME:RENEW EXTERNAL PERMADOR NO 180.93 Frame:Renew external door frame with any rebated proprietary

high performance door frame to suit any size single door, take out existing frame and bed new frame in cement mortar, plugged and screwed to brickwork and pointed with sealant, make good all works disturbed including refix or renew any internal beads, architraves etc., and remove waste and debris.

341203 R FRAME:RENEW PERMADOR FRAME WITH CILL COMPLETE NO 193.27 Frame:Renew external door frame with any rebated proprietary

high performance door frame with cill to suit any size single door, take out existing frame and bed new frame in cement mortar, plugged and screwed to brickwork and pointed with sealant, make good all works disturbed including refix or renew any internal beads, architraves etc., and remove waste and debris.

Page 133: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

99 Local Space Housing

341205 R FRAME:RENEW PERMADOR FANLIGHT COMPLETE NO 302.82 Frame:Renew external door frame with any rebated proprietary

high performance door frame and fanlight over, to suit any size single door, remove existing frame and bed new frame in mortar, plugged and screwed to brickwork and pointed with sealant, make good all works disturbed including refix or renew any internal beads, architraves etc., double glaze to fanlight and remove waste and debris.

341207 R FRAME:RENEW PERMADOR FANLIGHT CILL NO 315.16 Frame:Renew external door frame with any rebated proprietary

high performance door frame with cill and fanlight to suit any size single door, remove existing frame and bed new frame in mortar, plugged and screwed to brickwork and pointed with sealant, make good all works disturbed including refix or renew any internal beads, architraves etc., double glaze to fanlight and remove waste and debris.

Door Frames - Water Bars 341701 R WATERBAR:RENEW NO 15.60 Waterbar:Renew ne 914mm long proprietary waterbar screwed to

timber or concrete including plugging and bedded in sealant.

341705 R WATERBAR:REFIX WATERBAR NO 9.12 Waterbar:Lift existing proprietary waterbar, clean and refix, screw

to timber and bed in sealant.

Door and Window Frames - Draughtproofing Strips and

Sections

341901 R WEATHERSTRIP:FIX AA TO DOOR AND FRAME NO 26.05 Weatherstrip:Supply and fix anodised aluminium proprietary

weatherstrip to door and frame.

341903 R WEATHERSTRIP:RENEW REBATED TO DOOR NO 30.42 Weatherstrip:Renew proprietary rebated weatherstrip to edge of

timber door.

341905 R CILL:RENEW OR SUPPLY AND FIX STORMGUARD CILL NO 52.29 Cill:Supply and fix Stormguard stormproof cill to existing cill

including remove and rehang door, fix new cill including adapting door and existing cill as necessary and make good.

341907 R CILL:REFIX STORMGUARD THRESHOLD CILL NO 8.90 Cill:Refix Stormguard stormproof cill or proprietary threshold to existing

cill including remove and rehang door as necessary, refix cill or threshold and make good.

341921 R DRAUGHTPROOF:RENEW FOAM STRIP LM 2.54 Draughtproof:Renew existing or supply and fix new vinyl sheathed

compressible polyurethane foam draught strip with adhesive backing to any door or window at any level.

341923 R DRAUGHTPROOF:RENEW PLASTIC BRUSH TYPE LM 7.04 Draughtproof:Renew existing or supply and fix new brush or pile

type draught excluder with rigid PVC carrier, to any door or window at any level including fixing with pins to timber.

Page 134: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

100 Local Space Housing

Door Frames, Linings and Casings - Internal - Timber 342105 R FRAME:RENEW INTERNAL WITH STOPS AND ARCHITRAVES NO 105.71 Frame:Renew internal softwood door frame or lining with new

lining ne 32x144mm to suit any size single door, plugged to brickwork, complete with 14x27mm softwood door stops and ne 25x75mm set of softwood architraves both sides, make good all works disturbed and decorate to match existing and remove waste and debris.

342107 R FRAME:RENEW INTERNAL STOPS+ARCHS+DOOR REMOVAL NO 126.12 Frame:Renew internal softwood door frame or lining with new

lining ne 32x144mm to suit any size single door, remove existing door and set aside, take out existing frame, stops and architraves and plug frame to brickwork, complete with 14x27mm softwood door stops and set of ne 25x75mm softwood architraves both sides, rehang door, ease and adjust, refix keep including housing out, make good all works disturbed and decorate to match existing and remove waste and debris.

342115 R FRAME:RENEW INTERNAL FANLIGHT ARCHITRAVE STOPS NO 171.34 Frame:Renew internal door frame or lining with fanlight over with

32x144mm softwood door lining with fanlight to suit any size single door, plugged to brickwork, fanlight glazed and secured with and including screwed beads, complete with 14x27mm softwood door stops and ne 25x75mm softwood architraves both sides, make good to all works disturbed and decorate to match existing and remove waste and debris..

Door Frame - Repairs - Timber 342301 R FRAME:RENEW CLOSING EXTERNAL JAMB NO 59.47 Frame:Renew closing jamb of single external door frame, joint new

any size and profile preservative treated softwood door frame, splayed jointed to head, bedded in cement mortar, plugged and screwed to brickwork, including take off and refix stop and architrave, take off and refix lock and keep including housing out, decorate to match existing and make good all works disturbed including renew sealant and remove waste and debris.

342303 R FRAME:RENEW HANGING EXTERNAL JAMB NO 68.22 Frame:Renew hanging jamb of single external door frame, remove

existing door and set aside, cut out frame, joint new any size and profile preservative treated softwood door frame to head frame, bedded in cement mortar, plugged and screwed to brickwork including take off and refix stop and architraves, cut out housing for butts and rehang door, ease and adjust, and decorate to match existing and make good all works disturbed including renew sealant and remove waste and debris.

342307 R FRAME:SPLICE EXTERNAL REPAIR NE 1.0M NO 34.59 Frame:Cut out and splice new piece ne 1.00m long into external

door frame, including remove and rehang door, remove and refix keep as necessary, ease and adjust and make good butt recesses in frame, point with sealant, and decorate to match existing and remove waste and debris.

Page 135: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

101 Local Space Housing

342309 R FRAME:REFIX LOOSE EXTERNAL FRAME NO 33.85 Frame:Remove and refix loose external door frame, including

remove and refix door and one set of architraves, touch up decorations and renew sealant and remove waste and debris..

342311 U FRAME:REPAIR AFTER FORCED ENTRY NO 17.94 Frame:Repair external door frame after forced access, cut out and

splice in new piece to frame, remove and refix keep or hinge, and touch up decoration.

342313 R FRAME:RAKE OUT AND REPOINT EXTERNAL SEALANT LM 2.25 Frame:Rake out and repoint external door frame with sealant. 342315 R FRAME:RENEW HARDWOOD CILL NO 83.40 Frame:Renew any size hardwood cill to door frame including

remove old cill, remove and rehang door, fix new cill bedded in cement mortar including new water bar, redecorate cill to match existing and make good all finishes disturbed and remove waste and debris.

342317 R FRAME:RENEW INTERNALCLOSING JAMB NO 47.07 Frame:Renew closing jamb of single internal door frame with any

size and any profile softwood door frame, jointed to head, plugged to brickwork, including take off, renew 14x27mm stop and refix architraves, take off and refix lock keep including housing out, decorate to match existing and make good all work disturbed and remove waste and debris.

342321 R FRAME:SPLICE INTERNAL REPAIR NO 24.90 Frame:Cut out and splice new piece ne 1.00mm long into internal

door frame, remove/rehang door as necessary, including ease and adjust, make good butt recesses in frame, remove/refix architraves and stops as necessary and decorate to match existing.

342323 R FRAME:REFIX LOOSE INTERNAL DOOR FRAME NO 22.10 Frame:Remove and refix loose internal door frame, including

remove and refix door and two sets of architraves, make good finishes and touch up decorations.

342325 R FRAME:REPAIR LOOSE INTERNAL FRAME JOINTS NO 9.04 Frame:Repair loose or open joints to internal door frame, glue

joints, screw as necessary, clamp up joints, and touch up decorations.

Door Stops - Softwood 342501 R STOP:RENEW DOOR STOP SET IT 21.21 Stop:Renew any size upto 25x50mm planted softwood door stop

set to door frame and decorate to match existing.

342505 R STOP:REFIX LOOSE DOOR SET IT 3.72 Stop:Refix any loose door stop set to door frame. 342507 R STOP:RENEW OR SUPPLY 25X50MM FIRE DOOR STOP IT 22.32 Stop:Renew or supply any door stop with 25x50mm softwood door

stop set to fire check door, glued, screwed in accordance with BS459 Part 2 to door frame and prepare for redecoration.

Page 136: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

102 Local Space Housing

Door Frames - Intumescent Strips and Smoke Seals 343103 R INTUMESCENT STRIP:RENEW UPTO 1 HOUR LM 4.45 Intumescent Strip:Renew or supply and fix new intumescent strip,

upto one hour application, and setting into groove in timber frame or door.

343107 R INTUMESCENT STRIP:RENEW UPTO 1 HOUR SMOKE SEAL LM 5.16 Intumescent Strip:Renew or supply and fix new intumescent strip,

upto one hour application, with integral cold smoke seal and setting into groove in timber frame or door.

343111 R INTUMESCENT STRIP:RENEW UPTO 1 HOUR TO GLASS LM 10.48 Intumescent Strip:Renew or supply and fix new intumescent strip,

upto one hour application, and fixing to glass behind glazing beads.

343113 R SMOKE SEAL:RENEW TO FRAME 1/2 HOUR LM 9.39 Smoke Seal:Renew or supply and fix new 10x4mm cold smoke seal,

half hour application and setting into groove in timber frame or door.

Garage Doors and Frames Door - Garage - Matchboard - Softwood 345201 R DOOR:RENEW PAIR L AND B TO GARAGE IT 711.72 Door:Renew garage doors with new pair of 45mm softwood

preservative treated ledged, braced and matchboarded doors to suit size of existing opening with 169x20mm ledges and 106x20mm braces covered on face with 20mm tongued, grooved and V jointed jointed boarding and hang each leaf on one pair of 450mmm galvanised tee hinges, transfer existing lock and bolts, make good and decorate to match existing and remove waste and debris.

345203 R DOOR:EASE ADJUST GARAGE INCLUDING REMOVE NO 62.72 Door:Ease and adjust pair of garage doors, each hung on pair of

tee hinges, including remove and rehang doors, make good to frame and touch up decorations, and remove waste and debris.

Doors - Garage - Renewals - Up and Over Metal 345401 R GARAGE DOOR:RENEW METAL UP AND OVER IT 623.67 Garage Door:Renew any garage door with pre primed metal up and

over garage door, overall size ne 2.438x2.055m complete with all ironmongery and hanging to existing frame, make good to all works disturbed and decorate to match existing and remove waste and debris.

Doors - Garage - Repairs - Up and Over Metal 345601 R GARAGE DOOR:REMOVE AND REFIX UP AND OVER IT 66.08 Garage Door:Take down and rehang metal up and over garage

door, ease and adjust operating mechanism and leave operational, and touch up decorations, and remove waste and debris..

345603 R GARAGE DOOR:REPAIR UP AND OVER METAL IT 42.29 Garage Door:Repair any metal up and over garage door incl remove

fittings and door, straighten/repair dents and holes, rehang door, fittings and ease, and touch up decorations, and remove waste and debris..

Page 137: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

103 Local Space Housing

345605 R GARAGE DOOR:RENEW SPINDLE/ROLLER/CABLE NO 44.03 Garage Door:Renew spindle, roller and cable assembly to metal up

and over garage door and adjust.

345607 R GARAGE DOOR:RENEW LOCKING BAR TO UP AND OVER NO 25.40 Garage Door:Renew locking bar to metal up and over garage door

and adjust.

345609 R GARAGE DOOR:RENEW LOCK HANDLE TO UP AND OVER NO 33.69 Garage Door:Renew lock handle to metal up and over garage door,

adjust and provide two new keys to tenant.

345611 R GARAGE DOOR:RENEW LOCK TO UP AND OVER NO 19.22 Garage Door:Renew lock to metal up and over garage door,

including redrill for fixing bolts and alter door to receive new lock and collect and return keys to tenant.

345613 R GARAGE DOOR:RENEW ROLLERS AND CHANNELS IT 196.09 Garage Door:Renew set of rollers and guide channels to any metal

up and over garage door, adjust and leave operational, make good as necessary and remove waste and debris.

345615 R GARAGE DOOR:SUPPLY COUNTERBALANCE DOOR SPRING NO 74.32 Garage Door:Supply and fix new or renew any counterbalance door

spring to up and over garage door including removing existing fitting, adjust and leave operational, make good as necessary and remove waste and debris.

345617 R GARAGE DOOR:RENEW KEEP NO 20.73 Garage Door:Renew keep to any type of garage door lock including

removing existing fitting and make good operational, make good as necessary and remove waste and debris.

345619 R GARAGE DOOR:RENEW SUPPORT ARM IT 52.84 Garage Door:Renew support arm to any metal up and over garage

door, adjust and leave operational, make good as necessary and remove waste and debris

Door Frames - Garage - Timber 345701 R GARAGE FRAME:RENEW COMPLETE IT 109.17 Garage Frame:Renew garage door frame with matching tanalised

softwood frame to suit any size or type of door, remove existing door with fittings and set aside, take out existing frame, fix new frame into position including plugging, screwing and bedding as appropriate, point all round with sealant, rehang existing door complete with fittings, ease, adjust and adapt as necessary to leave operational, make good all works disturbed and decorate to match existing and remove waste and debris.

345703 R GARAGE FRAME:RENEW HEAD OR JAMB NO 40.82 Garage Frame:Renew head or jamb member to any type or size

garage door frame with matching tanalised softwood member, remove existing door with fittings and set aside, carefully remove defective section of frame, fix new member into position including plugging, screwing and bedding as appropriate, joint new member to existing retained members, point along new member with sealant, rehang existing door complete with fittings, ease, adjust and adapt as necessary to leave operational, make good all works disturbed and decorate to match existing and remove waste and debris.

Page 138: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

104 Local Space Housing

328109 R GARAGE FRAME:RENEW TO SIDE DOOR NO 168.03 Frame:Renew external garage door frame with any size or profile of

treated softwood door frame to suit any size single door, remove existing door and set aside, take out existing frame and bed new frame in cement mortar, plugged and screwed to brickwork and pointed with sealant, rehang door, ease and adjust including refix ironmongery, make good and decorate to match existing and remove waste and debris.

328111 R GARAGE FRAME:RENEW 25X75MM FILLET LM 11.15 Frame:Renew fillet any size or profile to garage door frame

including remove existing and decorate to match existing and remove waste and debris.

Internal Joinery Cladding or Linings - Internal Wall 350001 R LINING:TAKE DOWN AND CLEAR SM 3.06 Wall:Take down any type of wall linings, clear away and denail

studding, areas over 1.00sm and remove waste and debris.

350005 R PANELLING:RENEW IN HARDBOARD SM 20.61 Panelling:Remove existing hardboard panelling and renew with

3.2mm faced hardboard panelling fixed to softwood with brass cups and screws and remove waste and debris..

350007 R PANELLING:RENEW IN MAHOGANY PLYWOOD SM 18.38 Panelling:Remove existing panelling and renew with 6mm

mahogany veneered plywood panelling fixed to softwood with brass cups and screws and remove waste and debris..

Staircases 351001 R STAIRCASE:RENEW SOFTWOOD NOSING TO TREAD NO 23.32 Staircase:Renew rounded softwood nosing to tread, housed into

string including all wedges and blocks glued and screwed to face of existing tread, and decorate to match existing and remove waste and debris.

351003 R STAIRCASE:RENEW TREAD AND RISER UNIT NO 49.18 Staircase:Renew rounded softwood tread and plywood riser to

staircase tread housed into strings and including all wedges and blocks, glued and screwed and decorate to match existing and remove waste and debris.

351004 R STAIRCASE:RENEW TREAD NO 48.37 Staircase:Renew softwood tread to staircase housed into strings,

including all wedges and blocks, glued and screwed, prepare for redecoration.

351005 R STAIRCASE:RENEW WINDER TREAD-300MM NO 46.25 Staircase:Renew softwood winder tread to staircase 300mm

extreme width, including cutting to size and fix in place from underside of staircase and decorate to match existing and remove waste and debris.

Page 139: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

105 Local Space Housing

351007 R STAIRCASE:RENEW NEWEL POST NO 112.05 Staircase:Renew ne 100x100mm softwood newel or half newel post

ne 1.50m high, including cut to length, fix to place, and decorate to match existing and remove waste and debris.

351009 R STAIRCASE:RENEW SOFTWOOD BALUSTER NO 16.15 Staircase:Renew 25x25mm softwood baluster housed at each end

to string and handrail, and decorate to match existing and remove waste and debris.

351011 R STAIRCASE:SPLICE TO STRING NE 0.5M NO 40.14 Staircase:Renew section of wall or outer string to staircase ne

500mm long, splice in new section including remove and refix treads and risers as necessary and decorate to match existing and remove waste and debris.

351013 R STAIRCASE:REFIX LOOSE TREAD NO 8.83 Staircase:Refix any loose tread by screwing through tread into top

edge of riser (where there is no access to underside of staircase).

351015 R STAIRCASE:REFIX LOOSE NEWEL POST NO 15.61 Staircase:Refix any loose newel post, any length, including remove

and refix treads and risers if necessary, make good decorations to match existing.

351017 R STAIRCASE:REFIX LOOSE BALUSTER NO 4.52 Staircase:Refix any loose stair baluster, any size and length

including fixing to string and handrail as necessary, make good decorations to match existing.

351019 R STAIRCASE:OVERHAUL IT 86.03 Staircase:Overhaul existing staircase, clean off stair treads and

landings, punch in all nail heads, screw down all loose boards etc., securely fix all existing balustrades, wedge treads and risers and make good all works disturbed.

Handrails 352001 R HANDRAIL:RENEW 44X69MM NEWEL TYPE LM 33.29 Handrail:Renew 44x69mm half round softwood handrail, including

ramps and shaped ends, fixed between staircase newel posts, remove and refix balustrading as necessary and decorate to match existing and remove waste and debris.

352003 R HANDRAIL:RENEW 32X119MM NEWEL TYPE LM 41.95 Handrail:Renew 32x119mm rounded softwood handrail including

ramps and shaped ends fixed between staircase newel posts, remove and refix balustrading as necessary and decorate to match existing and remove waste and debris.

352005 R HANDRAIL:RENEW 44X69MM ON BRACKETS LM 14.15 Handrail:Renew with 44x69mm half round softwood handrail

including ramps and shaped ends, fixed to existing brackets and decorate to match existing and remove waste and debris.

352007 R HANDRAIL:RENEW 32X119MM ON BRACKETS LM 16.58 Handrail:Renew with 32x119mm rounded softwood handrail,

including ramps and shaped ends fixed to existing brackets and decorate to match existing and remove waste and debris.

Page 140: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

106 Local Space Housing

352009 R HANDRAIL:SUPPLY MOPSTICK INCLUDING BRACKETS LM 26.68 Handrail:Supply and fix 50x50mm softwood mopstick handrail on

and including brackets, plugged and screwed to walls and decorate to match existing and remove waste and debris.

352011 R HANDRAIL:SUPPLY OR RENEW GALVANISED MS BRACKET NO 16.53 Handrail:Supply and fix or renew galvanised mild steel handrail

bracket, fix to wall, and including any necessary plugging and make good plasterwork and decorations to match existing and remove waste and debris.

352017 R HANDRAIL:REFIX ON BRACKETS LM 7.59 Handrail:Refix handrail, fixed to existing brackets and make good decorate

to match existing.

352013 U HANDRAIL:REFIX LOOSE BRACKET NO 8.97 Handrail:Refix loose handrail bracket and including any necessary

plugging to wall and make good plasterwork and decorations to match existing

352015 R HANDRAIL:SUPPLY AND FIX PATTRESS NO 6.93 Handrail:Supply and fix new pattress to wall and including any

necessary plugging and make good plasterwork and decorations to match existing.

Miscellaneous Fixtures/Fittings Stool for Hot Water Cylinder 361001 R STOOL:RENEW TO CYLINDER NO 69.59 Stool:Renew or supply and fix wrot softwood stool for hot water

cylinder, finished sizes 515x515x610mm high, formed of four 50x50mm legs, eight 69x32mm horizontal runners and 19mm plywood top, remove and replace cylinder as necessary and test existing and remove waste and debris..

Tank Stands 361021 R TANK STAND:NEW FOR CWST IN LOFT NO 65.73 Tank Stand:Construct new tank stand in loft to suit any size or type

CWST ne 227 litres comprising 19mm thick plywood base on two 150x50mm bearers spanning minimum three ceiling joists with 100x38mm cross bearers at 300mm maximum centres existing and remove waste and debris..

361023 R TANK STAND:NEW REMOVE AND REFIX TANK IN LOFT NO 148.01 Tank Stand:Construct new or renew tank stand in loft to suit any

size or type CWST ne 227 litres comprising 19mm thick plywood base on two 150x50mm bearers spanning minimum three, ceiling joists with 100x38mm cross bearers at 300mm maximum centres, including isolating water supply, drain system, disconnect all pipework and set tank aside, remove and clear from site existing stand if applicable, reposition existing tank on new stand, reconnect all pipework and adjust as necessary, reinstate water supply, refill tank and test on completion existing and remove waste and debris..

Page 141: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

107 Local Space Housing

Hat and Coat Rails 362001 R HANGING RAIL:SUPPLY 25MM DIAMETER NE 3.0M LONG IT Hanging Rail:Supply and fix 25mm diameter plastic coated steel

tubular hanging rail, ne 3.00m long, each end housed into and including 100x38mm softwood bearers or chromium plated sockets.

35.83

362003 R HOOK:SUPPLY AND FIX HAT AND COAT HOOK NO 4.63 Hook:Supply and fix anodised aluminium hat and coat hook. 362050 R HAT COAT RAIL:RENEW OR SUPPLY COMPLETE IT 23.02 Hat Coat Rail:Renew or supply and fix 20x70mm twice rounded

wrot softwood hat and coat rail 1.00m long plugged and screwed to structure, decorated to match existing and supply and fix 3 No. anodised aluminium hat and coat hooks.

Curtain Battens and Tracks 363001 R CURTAIN BATTEN:RENEW OR FIX NEW IT 18.74 Curtain Batten:Renew or supply and fix new ne 25x75mm wrot

softwood curtain batten including remove existing including remove/ rehang rails and curtains, fix new batten plugged and screwed to any background, make good and decorate to match existing.

363011 R CURTAIN TRACK:RENEW INCLUDING RUNNERS LM 16.87 Curtain Track:Renew or supply and fix new proprietary plastic

curtain track system of any type and fixing to any type of background inclusive of all runners, brackets, end stops and similar fittings, plugging, screwing and making good as necessary.

Kitchen Units and Worktops Kitchen Units to match Existing 371001 R KITCHEN UNIT:RENEW SINGLE BASE TO MATCH EXISTING NO 102.43 Kitchen Unit:Renew any size or type of pre-finished single base unit

to match existing including plug and scribe to walls and any necessary grounds and make good all wall and floor finishes disturbed and remove waste and debris.

371003 R KITCHEN UNIT:RENEW DOUBLE BASE TO MATCH EXISTING NO 140.16 Kitchen Unit:Renew any size or type of pre-finished double base

unit to match existing including plug and scribe to walls and any necessary grounds and make good all wall and floor finishes disturbed and remove waste and debris.

371005 R KITCHEN UNIT:RENEW CORNER BASE TO MATCH EXISTING NO 148.77 Kitchen Unit:Renew any size or type of pre-finished corner base

unit to match existing including plug and scribe to walls and any necessary grounds and make good all wall and floor finishes disturbed and remove waste and debris.

371007 R KITCHEN UNIT:RENEW TALL FLOOR TO MATCH EXISTING NO 156.24 Kitchen Unit:Renew any size or type of pre-finished tall floor unit to

match existing including plug and scribe to walls and any necessary grounds and make good all wall and floor finishes disturbed and remove waste and debris.

Page 142: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

108 Local Space Housing

371009 R KITCHEN UNIT:RENEW SINGLE WALL TO MATCH EXISTING NO 79.18 Kitchen Unit:Renew any size or type of pre-finished single wall unit,

any height to match existing, including plug and scribe to walls and any necessary grounds and make good to all wall and ceiling finishes disturbed and remove waste and debris..

371011 R KITCHEN UNIT:RENEW DOUBLE WALL TO MATCH EXISTING NO 97.07 Kitchen Unit:Renew any size or type of pre-finished double wall

unit, any height, to match existing, including plug and scribe to walls and any necessary grounds and make good to all wall and ceiling finishes disturbed and remove waste and debris..

371013 R KITCHEN UNIT:RENEW CORNER WALL TO MATCH EXISTING NO 121.55 Kitchen Unit:Renew any size or type of pre-finished corner wall

unit, any height, to match existing, including plug and scribe to walls and any necessary grounds and make good to all wall and ceiling finishes disturbed and remove waste and debris..

Sink Tops and Sink Base Units [see Items 630105 to 630121 and 630301 to 630305 in PLUMBING] Kitchen Units - Clients Standard Specification 371021 R KITCHEN UNIT:RENEW SINGLE BASE 300X500 NO 89.75 Kitchen Unit:Renew any type of pre-finished single 300x500mm

base unit including plug and scribe to walls and any necessary grounds and make good all wall and floor finishes disturbed and remove waste and debris.

371023 R KITCHEN UNIT:RENEW SINGLE BASE 600X500 NO 98.90 Kitchen Unit:Renew any type of pre-finished single 600x500mm

base unit including plug and scribe to walls and any necessary grounds and make good all wall and floor finishes disturbed and remove waste and debris.

371025 R KITCHEN UNIT:RENEW SINGLE BASE 300X600 NO 86.70 Kitchen Unit:Renew any type of pre-finished single 300x600mm

base unit including plug and scribe to walls and any necessary grounds and make good all wall and floor finishes disturbed and remove waste and debris.

371027 R KITCHEN UNIT:RENEW SINGLE BASE 400X600 NO 91.46 Kitchen Unit:Renew any type of pre-finished single 400x600mm

base unit including plug and scribe to walls and any necessary grounds and make good all wall and floor finishes disturbed and remove waste and debris.

371029 R KITCHEN UNIT:RENEW SINGLE BASE 500X600 NO 102.43 Kitchen Unit:Renew any type of pre-finished single 500x600mm

base unit including plug and scribe to walls and any necessary grounds and make good all wall and floor finishes disturbed and remove waste and debris.

371031 R KITCHEN UNIT:RENEW SINGLE BASE 600X600 NO 105.24 Kitchen Unit:Renew any type of pre-finished single 600x600mm

base unit including plug and scribe to walls and any necessary grounds and make good all wall and floor finishes disturbed and remove waste and debris.

Page 143: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

109 Local Space Housing

371033 R KITCHEN UNIT:RENEW DOUBLE BASE 800MM NO 146.26 Kitchen Unit:Renew any type of pre-finished double 800x600mm

base unit including plug and scribe to walls and any necessary grounds and make good all wall and floor finishes disturbed and remove waste and debris.

371035 R KITCHEN UNIT:RENEW DOUBLE BASE 1000MM NO 149.07 Kitchen Unit:Renew any type of pre-finished double 1000x600mm

base unit including plug and scribe to walls and any necessary grounds and make good all wall and floor finishes disturbed and remove waste and debris.

371037 R KITCHEN UNIT:RENEW DOUBLE BASE 1200MM NO 169.80 Kitchen Unit:Renew any type of pre-finished double 1200x600mm

base unit including plug and scribe to walls and any necessary grounds and make good all wall and floor finishes disturbed and remove waste and debris.

371039 R KITCHEN UNIT:RENEW CORNER BASE 800MM NO 140.16 Kitchen Unit:Renew any type of pre-finished 800x600mm corner

base unit including plug and scribe to walls and any necessary grounds and make good all wall and floor finishes disturbed and remove waste and debris.

371041 R KITCHEN UNIT:RENEW CORNER BASE 1000MM NO 140.16 Kitchen Unit:Renew any type of pre-finished 1000x600mm corner

base unit including plug and scribe to walls and any necessary grounds and make good all wall and floor finishes disturbed and remove waste and debris.

371043 R KITCHEN UNIT:RENEW CORNER BASE 1200MM NO 181.99 Kitchen Unit:Renew any type of pre-finished 1200x600mm corner

base unit including plug and scribe to walls and any necessary grounds and make good all wall and floor finishes disturbed and remove waste and debris.

371045 R KITCHEN UNIT:RENEW LARDER UNIT NO 149.68 Kitchen Unit:Renew any type of pre-finished tall larder floor unit

including plug and scribe to walls and any necessary grounds and make good to all wall and floor finishes disturbed and remove waste and debris.

371047 R KITCHEN UNIT:RENEW APPLIANCE UNIT 1950MM NO 161.41 Kitchen Unit:Renew any type of pre-finished 600x600x1950mm

high appliance housing unit including plug and scribe to walls and any necessary grounds and make good to all wall and floor finishes disturbed and remove waste and debris.

371049 R KITCHEN UNIT:RENEW APPLIANCE UNIT 600MM NO 161.41 Kitchen Unit:Renew any type of pre-finished 1000x600x600mm

high appliance housing unit including plug and scribe to walls and any necessary grounds and make good to all wall and floor finishes disturbed and remove waste and debris.

371051 R KITCHEN UNIT:RENEW SINGLE WALL 300X300 NO 57.84 Kitchen Unit:Renew any type of pre-finished single 300x300mm

wall unit, 900mm high, including plug and scribe to walls and any necessary grounds and make good to all wall and ceiling finishes disturbed and remove waste and debris.

Page 144: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

110 Local Space Housing

371053 R KITCHEN UNIT:RENEW SINGLE WALL 400X300 NO 64.06 Kitchen Unit:Renew any type of pre-finished single 400x300mm

wall unit, 900mm high, including plug and scribe to walls and any necessary grounds and make good to all wall and ceiling finishes disturbed and remove waste and debris.

371055 R KITCHEN UNIT:RENEW SINGLE WALL 500X300 NO 68.45 Kitchen Unit:Renew any type of pre-finished single 500x300mm

wall unit, 900mm high, including plug and scribe to walls and any necessary grounds and make good to all wall and ceiling finishes disturbed and remove waste and debris.

371057 R KITCHEN UNIT:RENEW SINGLE WALL 600X300 NO 74.30 Kitchen Unit:Renew any type of pre-finished single 600x300mm

wall unit, 900mm high, including plug and scribe to walls and any necessary grounds and make good to all wall and ceiling finishes disturbed and remove waste and debris.

371059 R KITCHEN UNIT:RENEW DOUBLE WALL 1000X300 NO 97.07 Kitchen Unit:Renew any type of pre-finished double 1000x300mm

wall unit, 500mm high including plug scribe to walls and any necessary grounds and make good to all wall and ceiling finishes disturbed and remove waste and debris.

371061 R KITCHEN UNIT:RENEW DOUBLE WALL 1000X300 NO 101.09 Kitchen Unit:Renew any type of pre-finished double 1000x300mm

wall unit, 900mm high including plug scribe to walls and any necessary grounds and make good to all wall and ceiling finishes disturbed and remove waste and debris.

371063 R KITCHEN UNIT:RENEW DOUBLE WALL 1200X300 NO 136.22 Kitchen Unit:Renew any type of pre-finished double 1000x300mm

wall unit, 500mm high including plug scribe to walls and any necessary grounds and make good to all wall and ceiling finishes disturbed and remove waste and debris.

371065 R KITCHEN UNIT:RENEW DOUBLE WALL 1200X300 NO 152.31 Kitchen Unit:Renew any type of pre-finished double 1000x300mm

wall unit, 900mm high including plug scribe to walls and any necessary grounds and make good to all wall and ceiling finishes disturbed and remove waste and debris.

371067 R KITCHEN UNIT:RENEW CORNER WALL 500X300 NO 89.97 Kitchen Unit:Renew any type of pre-finished 500x300mm corner

wall unit, 500mm high including plug and scribe to walls and any necessary grounds and make good to all wall and ceiling finishes disturbed and remove waste and debris.

371069 R KITCHEN UNIT:RENEW CORNER WALL 600X300 NO 118.50 Kitchen Unit:Renew any type of pre-finished 600x300mm corner

wall unit, 500mm high including plug and scribe to walls and any necessary grounds and make good to all wall and ceiling finishes disturbed and remove waste and debris.

371071 R KITCHEN UNIT:RENEW DRAWER PACK 500X600 NO 148.16 Kitchen Unit:Renew any type of pre-finished 500x600mm drawer

pack unit including plug and scribe to walls and any necessary grounds and make good all wall and floor finishes disturbed and remove waste and debris.

Page 145: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

111 Local Space Housing

371073 R KITCHEN UNIT:RENEW DRAWER PACK 600X600 NO 130.59 Kitchen Unit:Renew any type of pre-finished 600x600mm drawer

pack unit including plug and scribe to walls and any necessary grounds and make good all wall and floor finishes disturbed and remove waste and debris.

Worktops 372001 R WORKTOP:RENEW NE 40MM THICK POST FORMED LM 31.48 Worktop:Renew worktop with high density waterproof moisture

resistant chipboard worktop ne 40mm thick to suit unit width with 1.3mm laminated sheet, post formed one edge, reverse compensated, including veneer exposed edges, seal joint between worktop and wall with silicone sealant and make good damaged and renew any missing wall tiles and remove waste and debris.

372002 R WORKTOP:RENEW NE 40MM THICK DOUBLE POST FORMED LM 34.65 Worktop:Renew worktop with high density waterproof moisture

resistant chipboard worktop ne 40mm thick to suit unit width with 1.3mm laminated sheet, post formed on both opposing edges, reverse compensated, including veneer exposed edges, seal joint between worktop and wall with silicone sealant and make good damaged and renew any missing wall tiles and remove waste and debris..

372005 R WORKTOP:REMOVE AND REFIX LM 10.51 Worktop:Remove and securely refix any width worktop including

seal joint to wall with waterproof sealant and make good damaged and renew any missing wall tiles and remove waste and debris.

372007 R WORKTOP:RENEW VENEER EDGING LM 5.57 Worktop:Renew 1.3mm laminated sheet veneer edging to worktop

or edge of cupboard door fixed with adhesive.

372009 R WORKTOP:PROVIDE END PANEL NO 64.42 Worktop:Supply and fix 18mm chipboard end panel melamine faced

both sides, PVC lipped on all edges, 600x870mm high, fixed to worktop and floor with plastic angle brackets.

372011 R WORKTOP:RENEW GALLOWS BRACKET NO 17.60 Worktop:Renew gallows bracket overall 305x458mm made out of

50x38mm softwood plugged and screwed to wall and decorate to match existing.

372013 R WORKTOP:RENEW LEG TO WORKTOP NO 22.73 Worktop:Renew chromium plated metal support leg to worktop with

flange plates screwed to floor and worktop.

372017 R WORKTOP:RENEW JOINT STRIP NO 17.28 Worktop:Renew aluminium joint strip between worktops including

remove and refix worktops as necessary and make good.

372019 R WORKTOP:25X25MM EDGE TRIM LM 5.41 Edge Trim:Supply and fix 25x25mm PVC/aluminium edge trim holed

and screwed to softwood.

372021 R WORKTOP:PROVIDE COVERBEAD NO 12.69 Worktop:Supply and fix proprietary aluminium ‘L’ shaped cover

bead rounded at end, screwed to edge of chipboard worktop.

Page 146: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

112 Local Space Housing

Kitchen Units - Repairs 373001 R KITCHEN UNIT:REMOVE AND REFIX ANY TYPE NO 19.25 Kitchen Unit:Remove and refix any kitchen unit including replug and

screw to walls and all making good.

373005 R KITCHEN UNIT:RENEW BLOCKBOARD DOOR NO 60.66 Kitchen Unit:Renew blockboard door to any kitchen unit on and

including pair of 50mm butt hinges, fit and hang, ease and adjust, including housing out unit for hinges and decorate to match existing and remove waste and debris.

373007 R KITCHEN UNIT:RENEW BASE UNIT DOOR NO 67.36 Kitchen Unit:Renew base unit door with melamine faced and edged

chipboard door to match existing, including pair of spring loaded concealed hinges, fit and hang, ease and adjust and remove waste and debris.

373009 R KITCHEN UNIT:RENEW WALL UNIT DOOR NO 67.22 Kitchen Unit:Renew any height wall unit door with melamine faced

and edged chipboard door to match existing, including pair of spring loaded concealed hinges, fit and hang, ease and adjust and remove waste and debris.

373011 R KITCHEN UNIT:RENEW TALL FLOOR UNIT DOOR NO 82.92 Kitchen Unit:Renew tall floor unit door with melamine faced and

edged chipboard door to match existing, including pair of spring loaded concealed hinges, fit and hang, ease and adjust and remove waste and debris.

373013 R KITCHEN UNIT:RENEW CUPBOARD BACK NO 27.02 Kitchen Unit:Renew cupboard back with 3mm self finished

hardboard, size approximately upto 1200mm wide x 900mm high.

373015 R KITCHEN UNIT:RENEW SHELF TO UNIT NO 11.89 Kitchen Unit:Renew shelf to base or wall unit with 19mm thick

melamine faced and edged chipboard, fixed to existing bearers.

373019 R KITCHEN UNIT:RENEW BOTTOM SHELF NO 14.08 Kitchen Unit:Renew bottom shelf to base unit with 19mm thick

melamine faced and edged chipboard, ne 575mm deep x 1150mm wide overall, cut and fit to unit.

373021 R KITCHEN UNIT:RENEW SIDE PANEL NO 53.65 Kitchen Unit:Renew side panel to any base unit with melamine

faced and edged chipboard replacement panel including cut and fit to unit.

373023 R KITCHEN UNIT:RENEW PLINTH NO 4.19 Kitchen Unit:Renew plinth to any base unit with melamine faced

and edged chipboard replacement plinth including cut and fit to unit.

373027 R KITCHEN UNIT:RENEW DRAWER BOX COMPLETE NO 63.95 Kitchen Unit:Renew drawer to kitchen unit with proprietary plastic

drawer box complete with runners, remove existing front from old drawer and refix to new drawer box and test and adjust as necessary.

Page 147: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

113 Local Space Housing

373045 R KITCHEN UNIT:RENEW OR INSTALL CHILD LOCK IT 19.50 Kitchen Unit:Renew or supply and install child proof locks to any

type of kitchen unit including removing existing if applicable, cutting out, adjusting door, piecing in and make good.

373049 R KITCHEN UNIT:OVERHAUL ANY TYPE NO 27.71 Kitchen Unit:Overhaul any kitchen unit including replug and screw to

walls, ease and adjust doors, refix hinges, pull handles, child locks, resecure drawer fronts, reglue loose veneers, adjust drawer runners, and all making good.

Wardrobe Units Fitted Wardrobe - Repairs 375003 R WARDROBE:EASE AND ADJUST INCLUDING REMOVE NO 17.43 Wardrobe:Ease and adjust any hanging, sliding or sliding/folding

door, including removing and refixing door, make good and touch up decorations.

375005 R WARDROBE:PATCH OR REPAIR NO 15.81 Wardrobe:Carry out any patch or repair to door, framing or

casework of any fitted wardrobe including cut out and splice in new timber upto 600mm long, make good and decorate to match existing.

375007 R WARDROBE:RENEW HINGE NO 8.21 Wardrobe:Renew butt or concealed hinge to door including

removing existing, adjustment and realignment of door, make good and touch up decorations as necessary.

375009 R WARDROBE:OVERHAUL REPAIR SLIDING GEAR IT 27.71 Wardrobe:Overhaul and repair any existing sliding or sliding/folding

door gear to fitted wardrobe, remove and refix door(s), lubricate as necessary and leave in working order and remove waste and debris.

375011 R WARDROBE:RENEW SLIDING GEAR IT 46.77 Wardrobe:Renew any sliding or sliding/folding door gear to fitted

wardrobe, remove and refix door(s), make good and touch up decorations as necessary.

375013 R WARDROBE:RENEW DOOR HANDLE NO 8.39 Wardrobe:Renew any door handle to fitted wardrobe, remove

existing fitting, making good and touch up decorations as necessary.

375015 R WARDROBE:RENEW ANY LOCK NO 18.03 Wardrobe:Renew any lock to fitted wardrobe, remove existing

fitting, making good and touch up decorations as necessary.

Skirtings, Rails and Architraves Skirting - Softwood 381001 R SKIRTING:RENEW SOFTWOOD SKIRTING LM 20.06 Skirting:Renew any size softwood plain, moulded or chamfered

skirting plugged to brickwork, including all ends and angles and decorate to match existing and remove waste and debris.

Page 148: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

114 Local Space Housing

381003 R SKIRTING:TAKE OFF AND REFIX LM 6.71 Skirting:Take off and refix existing skirting including denail skirting

and touch up decorations

Picture Rail 382001 R RAIL:TAKE OFF EXISTING AND MAKE GOOD LM 3.65 Rail:Take off existing picture rail, clear away and make good

plasterwork and remove surplus spoil.

Architraves - Softwood 383001 R ARCHITRAVE:RENEW SET TO ONE SIDE OF DOOR IT 25.57 Architrave:Renew any size softwood plain, moulded or chamfered

architrave set to one side of door frame including all mitres and scribing and decorate to match existing and remove waste and debris.

383003 R ARCHITRAVE:RENEW LEG OR HEAD ONE SIDE IT 10.06 Architrave:Renew any size softwood plain, moulded or chamfered

architrave to leg or head of door frame one side including all mitres and scribing and decorate to match existing and remove waste and debris.

383007 R ARCHITRAVE:REFIX ANY LOOSE IT 6.78 Architrave:Refix including take off as necessary any loose architrave

to both sides of door frame including touch up decorations to match existing.

Thresholds to Door Openings 384001 R THRESHOLD:RENEW TO DOOR OPENING IT 15.84 Threshold:Renew 19x150mm twice splayed and twice rounded

hardwood door threshold ne 1.00m long including notch and fit ends and decorate to match existing and remove waste and debris.

384003 R THRESHOLD:RESECURE LOOSE IT 8.01 Threshold:Resecure loose door threshold. Shelving 385001 R SHELVING:RENEW WROT SOFTWOOD BEARERS LM 5.11 Shelving:Renew ne 20x69mm wrot softwood bearers including plug

to walls and make good and decorate to match existing and remove waste and debris.

385003 R SHELVING:RENEW SLATTED COMPLETE IT 42.52 Shelving:Renew slatted shelving consisting of 20x44mm slats at

75mm centres on and including 25x50mm cross bearers at 500mm centres and remove waste and debris.

385005 R SHELVING:MELAMINE FACED NE 300MM LM 9.36 Shelving:Supply and fix melamine faced chipboard shelving ne

300mm wide cut to length and fix to bearers or brackets.

385007 R SHELVING:12MM PLYWOOD HARDWOOD EDGED NE 300MM LM 17.90 Shelving:Renew 12mm plywood ne 300mm wide, cut to length with

hardwood edging glued and pinned and fix to bearers or brackets and decorate to match existing and remove waste and debris.

Page 149: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

115 Local Space Housing

385009 R SHELVING:18MM BLOCKBOARD HARDWOOD EDGED NE 300MM LM 18.59 Shelving:Renew 18mm blockboard ne 300mm wide, cut to length with

hardwood edging glued and pinned and fix to bearers or brackets and decorate to match existing and remove waste and debris.

Windowboards 386001 R WINDOWBOARD:RENEW SOFTWOOD LM 34.78 Windowboard:Renew ne 25x300mm softwood windowboard

plugged, screwed and pellated to brickwork, make good plasterwork and decorations and decorate to match existing and remove waste and debris.

386003 R WINDOWBOARD:RENEW MDF LM 33.19 Windowboard:Renew ne 25x300mm MDF windowboard plugged,

screwed and pellated to brickwork, make good plasterwork and decorations and decorate to match existing and remove waste and debris.

386005 R WINDOWBOARD:RENEW HARDWOOD LM 45.72 Windowboard:Renew ne 25x300mm hardwood windowboard

plugged, screwed and pellated to brickwork, make good plasterwork and decorations and decorate to match existing and remove waste and debris.

386009 R WINDOWBOARD:RENEW PVCU LM 37.62 Windowboard:Renew existing with PVCu ne 25x300mm

windowboard fixed with approved adhesive or other approved concealed fixing method to brickwork, make good plasterwork and decorations.

386007 R WINDOWBOARD:REFIX LOOSE NO 6.93 Windowboard:Refix any size or type of loose windowboard to

window including removing if necessary, making good and touching up decorations.

Duct Casings 387001 R DUCT:RENEW PLYWOOD DUCT CASING SIDE NE 300MM LM 21.52 Duct:Renew pipe duct casing side with 6mm plywood casing upto

300mm wide, screw to framing with brass cups and screws and decorate to match existing and remove waste and debris.

387003 R DUCT:RENEW PLYWOOD SIDED DUCT CASING OVER 300MM SM 56.16 Duct:Renew pipe duct casing with 6mm plywood casing over

300mm wide, screw to framing with brass cups and screws and decorate to match existing and remove waste and debris.

387007 R DUCT:RENEW PLYWOOD SIDED CASING-450MM LM 51.03 Duct:Renew two or three sided pipe duct casing ne 450mm girth

and framing, with 6mm plywood casing sides, screwed with brass cups and screws to and including 38x50mm framing including plug and screw to walls, form access points as necessary and decorate to match existing and remove waste and debris.

387009 R DUCT:RENEW PLASTERBOARD CASING NE 300MM LM 27.00 Duct:Renew pipe duct casing with 9.5mm plasterboard casing ne

300mm wide, fixed to framing and with 3mm plaster skim coat including all angles, joints to existing and decorate to match existing and remove waste and debris.

Page 150: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

116 Local Space Housing

387011 R DUCT:RENEW PLASTERBOARD CASING OVER 300MM SM 60.22 Duct:Renew pipe duct casing with 9.5mm plasterboard casing over

300mm wide, fixed to framing and with 3mm plaster skim coat, form all angles and joints to existing and decorate to match existing and remove waste and debris.

387015 R DUCT:RENEW PLASTERBOARD SIDED NE 450MM LM 55.16 Duct:Renew two or three sided pipe duct casing ne 450mm girth

and framing, with 9.5mm plasterboard casing fixed to and including 38x50mm framing including plug and screw to walls, form access points as necessary, form all angles and joints to existing and decorate to match existing and remove waste and debris.

387017 R CLIENT INSPECTION:REMOVE AND REFIX DUCT CASING LM 9.12 Duct:Remove pipe duct casing for client inspection and later refix

including all making good and make good decorations to match existing and remove waste and debris.

387019 R DUCT:FORM ACCESS PANEL IN EXISTING IT 47.04 Duct:Form access panel in existing duct casing, remove plywood

casing as necessary, cut out and form access panel fixed with brass cups and screws including all additional framing and make good decorations to match existing and remove waste and debris.

Bath Panels and Framing 388001 R BATH PANEL:RENEW HARDBOARD SIDE AND FRAMING IT 64.37 Bath Panel:Renew or supply and fix 4.8mm self finished hardboard

side bath panel, securely screwed with chromium plated dome headed screws to and including 38x50mm softwood framing and remove waste and debris.

388003 R BATH PANEL:RENEW HARDBOARD END AND FRAMING IT 40.16 Bath Panel:Renew or supply and fix 4.8mm self finished hardboard

end bath panel, securely screwed with chromium plated dome headed screws to and including 38x50mm softwood framing complete with metal bath panel trim and remove waste and debris.

388005 R BATH PANEL:RENEW HARDBOARD SIDE END AND FRAMING IT 94.75 Bath Panel:Renew or supply and fix 4.8mm self finished hardboard

side and end bath panels securely screwed with chromium plated dome screws to and including 38x50mm softwood framing complete with metal bath panel trim and remove waste and debris.

388007 R BATH PANEL:RENEW HARDBOARD SIDE EXISTING FRAMING IT 24.68 Bath Panel:Renew or supply and fix 4.8mm self finished hardboard

side bath panel securely screwed with chromium plated dome screws to existing framing and remove waste and debris.

388009 R BATH PANEL:RENEW HARDBOARD END EXISTING FRAMING IT 15.19 Bath Panel:Renew or supply and fix 4.8mm self finished hardboard

end bath panel securely screwed with chromium plated dome screws to existing framing complete with metal bath trim and remove waste and debris.

388011 R BATH PANEL:RENEW HARDBD SIDE END EXISTING FRAMING IT 34.04 Bath Panel:Renew or supply and fix 4.8mm self finished hardboard

side and end bath panels securely screwed with chromium plated dome screws to existing framing and including metal bath panel edge trim and remove waste and debris.

Page 151: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

117 Local Space Housing

388013 R BATH PANEL:RENEW ACRYLIC SIDE IT 47.73 Bath Panel Panel:Renew or supply and fix proprietary acrylic side

bath panel, colour to match, including all plinths, trims, corner pieces and the like, securely fixed with brackets and make good, and remove waste and debris.

388015 R BATH PANEL:RENEW ACRYLIC END IT 29.42 Bath Panel Panel:Renew or supply and fix proprietary acrylic end

bath panel, colour to match, including all plinths, trims, corner pieces and the like, securely fixed with brackets and make good, and remove waste and debris.

388017 R PATH PANEL:RENEW ACRYLIC SIDE AND END IT 69.14 Bath Panel Panel:Renew or supply and fix proprietary acrylic side

and end bath panel, colour to match, including all plinths, trims, corner pieces and the like, securely fixed with brackets and make good, and remove waste and debris.

388019 R BATH PANEL:REMOVE AND REFIX ANY TYPE NO 8.90 Bath Panel Panel:Remove and later refix any bath panel (side or

end) including any corner angle trim, skirting etc.

Ironmongery Butts, Hinges, etc. 390101 R HINGES:RENEW 63MM STORMPROOF PR 9.97 Hinges:Renew pair of 63mm anodised steel stormproof hinges

including remove and rehang casement.

390105 R HINGES:RENEW PAIR OF FRICTION PIVOTS PR 46.99 Hinges:Renew pair of friction hinges to pivot window including

remove and refix casement.

390107 R HINGES:RENEW STEEL BUTT HINGES IT 15.63 Hinges:Renew ne 1.5 pairs 100mm mild steel butt hinges, ease and

adjust door, make good to recesses in frame.

390109 R HINGES:RENEW BRASS BUTT HINGES IT 25.49 Hinges:Renew ne 1.5 pairs 100mm brass butt hinges, ease and

adjust door, make good to recesses in frame.

390111 R HINGES:RENEW PAIR TEE HINGES PR 16.49 Hinges:Renew pair of 300mm galvanised tee hinges, ease and

adjust door, make good to frame.

390113 R HINGES:RENEW PAIR OF 50MM BUTT HINGES PR 11.40 Hinges:Take off cupboard door and set aside, remove hinges and

renew with pair of 50mm butt hinges, rehang door, ease and adjust.

Sliding Sash Fittings 390301 U FASTENER:RENEW ANY TYPE OF SASH FASTENER NO 13.31 Fastener:Renew or supply and fix new any type of sash fastener

including make good and touch up decorations.

390307 R LIFT:RENEW SASH LIFT NO 9.08 Lift:Renew or supply and fix new sash lift.

Page 152: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

118 Local Space Housing

390309 R BOLT:RENEW SASH BOLT NO 19.06 Bolt:Renew or supply and fix new lockable sash bolt to centre rail of

sliding sash timber windows including make good and touch up decorations, hand key to Tenant.

390311 R LOCK:RENEW PAIR OF SASH LOCKS PR 52.17 Lock:Renew or supply and fix new pair of lockable sash locks to

restrict opening of sliding sash timber windows, including make good and touch up decoratations, hand key to Tenant.

390313 R SASH PINS:RENEW PAIR SASH PINS PR 34.39 Sash Pins:Renew or supply and fix new pair of dual sash pins to

centre rail of sliding sash timber windows, including make good and touch up decorations, hand key to Tenant.

Door Closers 390501 U CLOSER:RENEW LIGHT DUTY OVERHEAD NO 49.00 Closer:Renew approved light duty overhead door closer screwed to

door and frame.

390503 U CLOSER:RENEW HEAVY DUTY OVERHEAD NO 64.46 Closer:Renewapproved heavy duty overhead door screwed to door

and frame.

390505 U CLOSER:RENEW OR SUPPLY PERKO TYPE NO 12.89 Closer:Renew or supply and fix Perko type concealed door closer

screwed to door and frame.

390509 U CLOSER:RENEW GIBRALTER TYPE NO 18.22 Closer:Renew Gibralter type door closer screwed to door and frame. 390507 U CLOSER:EASE AND ADJUST ANY TYPE NO 6.71 Closer:Ease and adjust any type door closer. Floor Springs 390601 R FLOOR SPRING:RENEW SINGLE ACTION NO 213.93 Floor Spring:Renew or supply and install single action hydraulic

check for door maximum 2150x850mm complete with top plate, loose box 57mm deep for concrete, top centre and shoe, remove existing floor spring or form recess in floor, fix in position as manufacturer’s instructions, ease and adjust door, make good floor finishes and all other works disturbed and remove waste and debris.complete, remove existing or form recess in floor, fix as manufacturer’s instructions, make good and remove waste and debris.

390603 R FLOOR SPRING:RENEW DOUBLE ACTION NO 294.34 Floor Spring:Renew or install double action hydraulic check for door

maximum 2150x850mm complete with top plate, adjustable loose box 59mm deep for concrete, adjustable top centre and shoe, remove existing floor spring or form recess in floor, fix in position as manufacturer’s instructions, ease and adjust door, make good floor finishes and all other works disturbed and remove waste and debris.

390605 R FLOOR SPRING:OVERHAUL NO 22.59 Floor Spring:Overhaul and maintain floor spring to door, including

ease and adjust, oil moving parts

Page 153: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

119 Local Space Housing

Sliding Door Gear 390701 R SLIDING DOOR GEAR:REPAIR NO 29.16 Sliding Door Gear:Take off, repair and refix, aluminium or plastic

double track sliding door gear to pair of wardrobe doors maximum 1.5m opening, including removing and rehanging doors.

390703 R SLIDING DOOR GEAR:RENEW NO 63.17 Sliding Door Gear:Remove existing sliding door gear and renew

with anodised aluminium or plastic double track sliding door gear to pair of wardrobe doors maximum 1.5m opening, including removing and rehanging doors.

Locks 390901 U RIMLOCK:RENEW COMPLETE NO 88.52 Rimlock:Renew rimlock, keep and set of rimlock furniture, including

altering door as necessary for new lock and housing out existing frame as necessary and provide two new keys.

390903 U LOCK:RENEW MORTICE COMPLETE NO 37.84 Lock:Renew mortice lock, keep and set of anodised aluminium lever

handle furniture including altering door as necessary for new lock and provide two new keys.

390907 U LOCK:RENEW MORTICE KEEP NO 5.00 Lock:Renew mortice lock keep including housing out existing frame

as necessary.

390909 U LOCK:RENEW MORTICE DEADLOCK NO 32.54 Lock:Renew mortice deadlock, keep and set of escutcheons

including altering door as necessary for new lock and provide two new keys.

390911 U LOCK:RENEW 5L MORTICE COMPLETE NO 29.49 Lock:Renew 5 lever mortice lock, keep and set of anodised

aluminium lever handle furniture including altering door as necessary for new lock and provide two new keys.

390915 U LOCK:RENEW 5L MORTICE DEADLOCK NO 76.08 Lock:Renew 5 lever mortice deadlock, keep and set of escutcheons

including altering door as necessary for new lock and provide two new keys.

390917 E LOCK:OVERHAUL ANY LOCK COMPLETE NO 10.97 Lock:Remove any type of lock and furniture, dismantle, overhaul,

repair, oil and assemble and refix to door.

390919 U LOCK:RENEW WITH 5L MORTICE NO 46.99 Lock:Renew rimlock with 5 lever mortice lock, keep and set of

anodised aluminium lever handle furniture, including altering door as necessary for new lock and provide two new keys.

390921 U DOOR:RENEW MULTIPOINT LOCK NO 168.34 Door:Renew any defective or broken multipoint door locking system

complete to any type of door, adapt keep if necessary, including remove existing, test and leave in proper working order and provide two new keys.

Page 154: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

120 Local Space Housing

390923 U LOCK:RENEW EUROLOCK COMPLETE NO 41.13 Lock:Renew eurolock lock, keep and set of anodised aluminium

lever handle furniture including altering door as necessary for new lock and provide two new keys.

390927 U LOCK:RENEW PATIO DOOR LOCK COMPLETE NO 40.69 Lock:Renew multi point patio door lock and set of anodised aluminium

lever handle furniture and provide two new keys.

Latches 391101 R LATCH:RENEW MORTICE LATCH COMPLETE NO 22.21 Latch:Renew mortice latch, keep and set of anodised aluminium

lever handle furniture including altering door as necessary for new latch.

391107 R LATCH:OVERHAUL LATCH AND FURNITURE NO 9.04 Latch:Remove mortice latch and furniture, dismantle, overhaul,

repair, oil and assemble and refix to door.

Cylinder Night Latches 391301 U NIGHTLATCH:RENEW COMPLETE NO 62.84 Nightlatch:Renew cylinder rim night latch, keep and pull handle,

including altering door as necessary for new latch and provide two new keys.

391305 U NIGHTLATCH:RENEW CYLINDER BARREL NO 23.55 Nightlatch:Renew cylinder barrel to night latch and provide two

new keys.

391307 U NIGHTLATCH:RENEW SUITED CYLINDER BARREL NO 12.80 Nightlatch:Renew suited cylinder barrel to nightlatch and provide

two new keys.

391309 E NIGHTLATCH:OVERHAUL COMPLETE NO 10.97 Nightlatch:Remove any type of cylinder nightlatch, dismantle,

overhaul, repair, oil and assemble and refix to door.

391313 U NIGHTLATCH:RENEW PULL NO 14.14 Nightlatch:Renew nightlatch finger full, dismantle latch, install new

pull, oil and reassemble and refix to door.

Roller and Ball Catches 391501 R CATCH:RENEW CATCH AND KEEP NO 11.50 Catch:Renew catch and keep including altering door as necessary

for new catch and housing out frame for keep.

391503 R CUPBOARD:RENEW 50MM BRASS LOCK NO 17.88 Cupboard:Renew 50mm brass cupboard lock. 391505 R CUPBOARD:RENEW DOOR CATCH NO 8.45 Cupboard:Renew cupboard door catch (any type). 391507 R CUPBOARD:RENEW CATCH KEEP NO 6.88 Cupboard:Renew cupboard catch keep including housing out frame

as necessary.

Page 155: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

121 Local Space Housing

Bolts, Security Bolts, Panic Bolts and Padlocks 391701 U BOLT:RENEW NE 250MM PADBOLT NO 9.88 Bolt:Renew ne 250mm galvanised approved padbolt. 391703 U BOLT:RENEW 200MM TOWER BOLT NO 8.18 Bolt:Renew 200mm tower bolt and keep. 391705 U BOLT:RENEW NE 150MM BARREL BOLT NO 4.63 Bolt:Renew ne 150mm barrel bolt and keep. 391707 U BOLT:RENEW INDICATOR BOLT NO 13.57 Bolt:Renew 175mm SAA bathroom indicator bolt and keep. 391709 U BOLT:RENEW MORTICE SECURITY BOLT NO 41.27 Bolt:Renew or supply and fix new mortice security bolt with key

operation and keep

391711 U BOLT:RENEW SINGLE PANIC BOLT NO 60.06 Bolt:Renew approved SAA panic bolt and keep to single door. 391713 U BOLT:RENEW FIRE SECURITY BOLT NO 59.13 Bolt:Renew fire security bolt, surface fixed to emergency exit doors

comprising metal bolt held extended by clear glass tube retained by padlock including keep, hammer and chain.

391715 U BOLT:RENEW GLASS TO FIRE SECURITY BOLT NO 8.53 Bolt:Renew glass tube to fire security bolt including reset. 391719 U BOLT AND KEEP:REMOVE EASE AND REFIX NO 4.41 Bolt and Keep:Remove barrel bolt or bolt keep, oil and ease as

necessary and refix bolt and or bolt keep in new position.

391723 U PADLOCK:RENEW OR SUPPLY PADLOCK NO 10.52 Padlock:Renew or supply and fix 50mm galvanised approved

padlock with two keys and hand to Client Representative.

391725 U HASP:RENEW WITH STAPLE NO 17.61 Hasp:Renew any type of hasp and staple. 391727 U HASP:RENEW WITH PADLOCK NO 24.63 Hasp:Renew any type of hasp, staple and 50mm galvanised

approved padlock, supply two keys and hand keys to Client Representative.

Fittings to Timber Windows 391901 R WINDOW FITTING:RENEW BRASS CASEMENT CATCH NO 14.60 Window Fitting:Renew brass casement catch and keep to timber

window.

391905 R WINDOW FITTING:RENEW BRASS STAY AND FASTENER NO 15.21 Window Fitting:Renew any brass casement stay and two pin

fastener and fix to timber window.

391909 R WINDOW FITTINGS:RENEW AA CASEMENT CATCH NO 19.01 Window Fitting:Renew anodised aluminium standard or offset

casement catch and keep to timber window.

Page 156: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

122 Local Space Housing

391913 R WINDOW FITTINGS:RENEW AA STAY AND FASTENER NO 11.63 Window Fitting:Renew any anodised aluminium casement stay and

two pin fastener and fix to timber window.

391917 R WINDOW FITTINGS:RENEW ZINC ALLOY CASEMENT CATCH NO 10.16 Window Fitting:Renew epoxy coated zinc alloy standard or offset

casement catch and keep to timber window.

391921 R WINDOW FITTINGS:RENEW ZINC ALLOY STAY AND FASTENER NO 14.56 Window Fitting:Renew any epoxy coated zinc alloy casement stay

and two pin fastener and fix to timber window.

391925 R WINDOW FITTINGS:RENEW GALVANISED SAFETY FASTENER NO 20.78 Window Fitting:Renew galvanised safety window fastener and fix to

timber window.

391927 R WINDOW FITTINGS:RENEW PIVOT WINDOW FASTENER NO 19.58 Window Fitting:Renew pivot window fastener and receiver to timber

window.

391929 R WINDOW FITTINGS:RENEW RESTRICTOR STAY NO 25.66 Window Fitting:Renew window restrictor stay to timber window. 391931 R WINDOW FITTINGS:RENEW MORTICE SECURITY BOLT NO 36.96 Window Fitting:Renew/supply and fix new mortice security bolt with

key operation and keep and fix to timber window.

391933 R WINDOW FITTINGS:REFIX EASE ADJUST ANY TYPE NO 3.57 Window Fitting:Refix, ease and adjust any loose window fitting to

timber window.

391937 R WINDOW FITTINGS:RENEW WITH LOCKABLE TYPE STAY NO 25.12 Window Fitting:Renew any type/supply and fix new anodised

aluminium lockable casement stay and two threaded pin fasteners with key operation, fix to casement or fanlight of timber window, and provide two new keys.

391939 R WINDOW FITTINGS:RENEW LOCKABLE RESTRICTOR STAY NO 28.56 Stay:Renew any type/supply and fix new anodised aluminium

lockable restrictor security stay with key operation, fix to casement or fanlight of timber window, and provide two new keys.

391941 R WINDOW FITTINGS:RENEW LOCKABLE CASEMENT CATCH NO 25.92 Catch:Renew any type/supply and fix new anodised aluminium

lockable standard or offset casement catch and keep with key operation, fix to casement of timber window, and provide two new keys.

391943 U WINDOW FITTINGS:PROVIDE NEW KEYS NO 3.36 Window Fittings:Supply only window key including all necessary

cutting.

Fittings to Steel Windows 392101 R WINDOW FITTING:RENEW HINGES EASE ADJUST STEEL NO 28.35 Window Fitting:Renew hinges to casement sash or fanlight to

window frame and ease and adjust (casement and fanlight in place).

Page 157: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

123 Local Space Housing

392103 R WINDOW FITTING:RENEW FASTENER STAY TO STEEL SASH NO 16.14 Window Fitting:Renew casement fastener or fanlight stay or

casement stay or stay pin to steel window.

392109 R WINDOW FITTING:REPAIR, EASE, ADJUST TO STEEL SASH NO 9.48 Window Fitting:Repair stay, fastener or catch to steel window and

check, ease and adjust.

392111 R WINDOW FITTING:RENEW LOCKABLE STAY TO STEEL SASH NO 23.76 Window Fitting:Renew/supply and fix new lockable type lock or

restrictor stay with key operation to casement or fanlight to steel window, and provide two new keys.

Fittings to Aluminium Windows 392301 R WINDOW FITTINGS:RENEW FRICTION STAY TO ALUM SASH NO 19.15 Window Fittings:Renew friction stay to aluminium casement sash or

fanlight to window frame and ease and adjust (casement and fanlight in place).

392303 R WINDOW FITTINGS:RENEW FASTENER STAY TO ALUM SASH NO 13.59 Window Fittings:Renew casement fastener or fanlight stay or

casement stay or stay/pin to aluminium window.

392309 R WINDOW FITTINGS:REPAIR, EASE, ADJUST TO ALUM SASH NO 9.48 Window Fittings:Repair stay, fastener, catch or stay pin to ease

operation of aluminium window and check, ease and adjust.

Door Furniture including Viewer, Security Chain 392501 R DOOR FURNITURE:RENEW SET OF LEVER HANDLES NO 13.39 Door Furniture:Renew set of anodised aluminium lever latch or lock

furniture.

392505 R DOOR FURNITURE:RENEW SET OF KNOBS TO RIMLOCK NO 15.33 Door Furniture:Renew set of rimlock knob furniture. 392509 R DOOR FURNITURE:RENEW OR INSTALL VIEWER NO 12.11 Door Furniture:Renew or supply and fix new security door viewer

including drilling/adapting hole through door as necessary and make good.

392511 R DOOR FURNITURE:RENEW OR INSTALL CHAIN NO 9.77 Door Furniture:Renew or supply and fix new door security chain

and make good.

392513 R DOOR FURNITURE:REFIX ANY LOOSE FITTING NO 2.77 Door Furniture:Refix any loose door fitting to timber door. 392515 R DOOR FURNITURE:SUPPLY AND FIX KICKING PLATE NO 60.35 Door Furniture:Supply and fix 16 gauge SAA kicking plate ne

900x300mm, screw fixed to any door.

392517 R DOOR FURNITURE:RENEW PULL HANDLES NO 9.96 Door Furniture:Renew pull handle, SAA, 150mm. 392519 R DOOR FURNITURE:RENEW PUSH PLATES NO 18.27 Door Furniture:Renew push or finger plate, SAA, 225x50mm.

Page 158: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

124 Local Space Housing

392521 U DOORS:PROVIDE NEW NON-SUITED KEYS NO 4.27 Doors:Supply only non suited key including all necessary cutting. 392523 U DOORS:PROVIDE NEW SUITED KEYS NO 5.98 Doors:Supply only suited key including all necessary cutting. 392525 R DOOR FURNITURE:RENEW ESCUTCHEON SET NO 9.86 Door Furniture:Renew with set of escutcheons to match existing. 392527 R DOOR FURNITURE:RENEW BATHROOM ESCUTCHEON SET NO 19.39 Door Furniture:Renew with set of escutcheons to match existing

complete with turn button, indicator and emergency release.

Letterplates 392701 R LETTERPLATE:RENEW COMPLETE WITH KNOCKER NO 46.46 Letterplate:Renew letter plate and knocker including plugging and

redrilling holes and altering opening where necessary and provide and fix new brush type draught overluder.

392702 R LETTERPLATE:SUPPLY AND FIX NEW NO 72.72 Letterplate:Supply and fix new letter plate including cutting opening

and provide and fix new brush type draught excluder.

392703 R LETTERPLATE:RENEW FIREPROOF TYPE NO 50.57 Letterplate:Renew fireproof letter plate and knocker to suit

appropriate fire resisting door including plugging and redrilling holes and adapting opening where necessry.

392705 R LETTERPLATE:RENEW OR SUPPLY HIGH SECURITY COWL NO 31.02 Letterplate:Renew or supply and fix new high security internal letter

cowl screwed to internal face of door.

Door Numerals 392901 R DOOR NUMERAL:RENEW NE 3 NO IT 8.25 Door Numeral:Renew or replace ne 3 No. letters or numerals. Door Stop 393101 R DOOR STOP:PROVIDE RUBBER STOP NO 2.74 Door Stop:Supply and fix 25mm diameter rubber door stop to

softwood or masonry.

Cupboard Handles 393301 R CUPBOARD:RENEW CUPBOARD PULL NO 7.74 Cupboard:Renew 44mm satin anodised aluminium cupboard pull

handle.

393303 R CUPBOARD:RENEW PULL HANDLE NO 9.87 Cupboard:Renew 100mm satin anodised aluminium ‘D’ pull handle,

including plug holes where necessary.

393305 R CUPBOARD:REFIX PULL HANDLE NO 2.33 Cupboard:Refix loose pull handle. 393307 R CUPBOARD:RENEW KNOB NO 3.24 Cupboard:Renew satin anodised aluminium knob handle.

Page 159: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

125 Local Space Housing

Miscellaneous Works Ceiling Access Hatch 395101 R CEILING HATCH:FORM OPENING COMPLETE IT 149.32 Ceiling Hatch:Cut opening through ceiling for access hatch, trim

opening with ne 75x150mm pressure impregnated sawn softwood trimmers, 25x38mm softwood stops fixed to trimmers/joists, 19x69mm softwood architraves and 900x600x18mm blockboard trap, fully insulated, fix draught strips to perimeter of hatch, ironmongery, make good to plasterwork and decorate to match existing.

395103 R CEILING HATCH:RENEW BLOCKBOARD ACCESS HATCH IT 71.70 Ceiling Hatch:Renew with 18mm blockboard access hatch, fully

insulated including fit new draught strips, all ironmongery and decorate to match existing.

395105 R CEILING HATCH:FIX NEW PROPRIETARY HATCH IT 194.05 Ceiling Hatch:Cut opening through ceiling, trim opening as

necessary and supply and fix proprietary purpose make ceiling access hatch complete, make good all finishes and decorations.

395107 R CEILING HATCH:RENEW PROPRIETARY HATCH IT 138.69 Ceiling Hatch:Renew existing proprietary ceiling hatch, remove

existing, supply and fix proprietary purpose make ceiling access hatch complete, make good all finishes and decorations.

395109 R CEILING HATCH:OVERHAUL HATCH IT 13.84 Ceiling Hatch:Repair access hatch including remove and refix hatch

and ironmongery as necessary and leave in working order and remove waste and debris.

395111 R CEILING HATCH:RENEW DRAUGHT INSULATION STRIPS IT 12.08 Ceiling Hatch:Renew or supply and fix draught insulation strips to

access hatch.

Gain Entry 396001 E DWELLING:GAIN ACCESS IT 53.45 Dwelling:Gain access for eviction or for tenant locked out or

emergency works, including force access to door, cut out and splice in new piece to external door frame, touch up decorations, provide new barrel and two keys as necessary or gain access through window including remove existing glass, gain access, reglaze including make good and touch up decorations.

396006 U GARAGE:GAIN ACCESS NO 45.08 Garage:Gain access for tenant, including force access including

redrill for fixing bolts and alter door, provide new lock and collect and return keys to tenant.

Boarding Up/Nailing Up 397001 E OPENING:BOARD UP WITH 12MM STERLING OR PLYWOOD NO 27.89 Opening:Board up window or door with 12mm Sterling or plywood

board or blockboard including cut to size, nail over window or door (NOT to frame) and leave secure (per opening).

Page 160: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

126 Local Space Housing

397003 E OPENING:REMOVE BOARDING TO OPENINGS NO 7.29 Opening:Remove boarding from window or door opening and make

good. Leave property secure including refix boarding if required.

397005 E OPENING:NAIL UP WINDOW OR DOOR NO 5.61 Opening:Nail up window or door and leave secure. 397007 U OPENING:REMOVE NAILS FROM OPENING NO 3.21 Opening:Remove nails from window or door and make good (per

window or door).

Boarding Up Long Term Voids 397021 E OPENINGS:SECURITY FULL SCREENS FIRST WEEK IT 64.58 Openings:Provide and install for an open period proprietary metal

security screens to cover upto 2 doors and 8 windows, any size and type of opening, take down and refix as required during contract duration of Void Dwelling, leave secure when dwelling unattended and remove and make good on completion including providing security alarm if necessary (applicable to first week only).

397023 E OPENINGS:SECURITY EXTRA WINDOW FIRST WEEK NO 7.53 Openings:Provide and install for an open period an additional

proprietary metal security window screen to suit any size and type of opening window, take down and refix as required during contract duration of Void Dwelling, leave secure when dwelling unattended and remove and make good on completion (applicable to first week only).

397024 X OPENINGS:SECURITY EXTRA WINDOW ADDITIONAL HIRE NO 6.48 Openings:Hire and maintenance of one proprietary metal security window

screen to suit any size and type of opening window, for additional hire period beyond the initial hire period of one week, (only to be claimed when instructed by the Client Representative as an additional item) including any additional taking down and refixing as required during during contract duration of Void Dwelling, leave secure when dwelling unattended (per additional week of hire to 397023).

397025 E OPENINGS:SECURITY EXTRA DOOR FIRST WEEK NO 13.92 Openings:Provide and install for an open period an additional

proprietary metal security door screen to suit any size and type of door opening, take down and refix as required during contract duration of Void Dwelling leave secure when dwelling unattended and remove and make good on completion (applicable to first week only).

397026 X OPENINGS:SECURITY EXTRA DOOR ADDITIONAL HIRE NO 7.53 Openings:Hire and maintenance of one proprietary metal security door

screen to suit any size and type of door opening, for additional hire period beyond the initial hire period of one week, (only to be claimed when instructed by the Client Representative as an additional item) including any additional taking down and refixing as required during during contract duration of Void Dwelling, leave secure when dwelling unattended (per additional week of hire to 397025).

Page 161: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

127 Local Space Housing

397027 X OPENINGS:SECURITY FULL ADDITIONAL HIRE NO 25.38 Openings:Hire and maintenance of proprietary metal security

screens to cover upto 2 doors and 8 windows for additional hire period beyond the initial hire period of one week, (only to be claimed when instructed by the Client Representative as an additional item) including any additional taking down and refixing as required during contract duration of Void Dwelling, leave secure when dwelling unattended including providing security alarm if necessary (per additional week of hire to to 397021).

397029 E OPENINGS:SECURITY PARTIAL SCREENS FIRST WEEK IT 50.93 Openings:Provide and install for an open period proprietary metal

security screens to cover upto 2 doors and 2 windows, any size and type of opening, take down and refix as required during contract duration of Void Dwelling, leave secure when dwelling unattended and remove and make good on completion including providing security alarm if necessary (applicable to first week only).

397031 X OPENINGS:SECURITY PARTIAL ADDITIONAL HIRE NO 20.13 Openings:Hire and maintenance of proprietary metal security

screens to cover upto 2 doors and 2 windows for additional hire period beyond the initial hire period of one week, (only to be claimed when instructed by the Client Representative as an additional item) including any additional taking down and refixing as required during contract duration of Void Dwelling, leave secure when dwelling unattended including providing security alarm if necessary (per additional week of hire to 397029).

397033 E OPENINGS:SECURITY INDIVIDUAL FIRST WEEK NO 34.92 Openings:Provide and install for an open period an individual proprietary

metal security window or door screen to suit any size of and type of opening, take down and refix as required during contract duration of Void Dwelling, leave secure when dwelling unattended and remove and make good on completion (applicable to first week only).

397035 X OPENINGS:SECURITY INDIVIDUAL ADDITIONAL HIRE NO 7.53 Openings:Hire and maintenance of one proprietary metal security

window or door screen, for additional hire period beyond the initial hire period of one week, (only to be claimed when instructed by the Client Representative as an additional item) including any additional taking down and refixing as required during during contract duration of Void Dwelling, leave secure when dwelling unattended (per additional week of hire to 397033).

Carpentry and Joinery – Client Inspections 398001 U CLIENT INSPECTION:EXTERNAL JOINERY IT 13.13 Client Inspection:Undertake client inspection and testing etc and

report to Client Representative (any repairs required to be ordered must be instructed by Client Representative)

Page 162: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

128 Local Space Housing

PLASTERWORK AND OTHER FINISHES Plasterwork, Rendering and Screeds Plasterwork - Walls 411105 R WALL:RENEW APPLY 3MM SKIM PLASTER IN PATCH IT 13.88 Wall:Renew defective or apply new skim coat of plaster in patch

including hack off existing and renew including all preparation and joints to existing surfaces and remove waste and debris.

411107 R WALL:RENEW APPLY 3MM SKIM COAT PLASTER SM 10.82 Wall:Renew defective or apply new skim coat of plaster including

hack off existing and renew including all preparation and joints to existing surfaces and remove waste and debris.

411113 R WALL:FLOAT SET DUB OUT IN PATCH IT 32.62 Wall:Float and set to walls in patch including additional coat or dub

out as necessary with cement and sand including all labours, and remove waste and debris.

411115 R WALL:FLOAT SET DUB OUT SM 28.24 Wall:Float and set to walls including additional coat or dub out as

necessary with cement and sand including all labours, and remove waste and debris.

411121 R WALL HACK REPLASTER DUB OUT IN PATCH IT 48.97 Wall:Hack off plaster, rake out and prepare background, float and

set to walls in patch including additional coat or dub out as necessary with cement and sand including all labours, and remove waste and debris.

411123 R WALL:HACK REPLASTER DUB OUT SM 42.41 Wall:Hack off plaster, rake out and prepare background, float and

set to walls including additional coat or dub out as necessary with cement and sand including all labours and remove waste and debris.

411133 R WALL:BOND AND SET WALL IN PATCH IT 20.78 Wall:Bond and set to walls in patch including additional coat or dub

out as necessary with cement and sand including all labours, and remove waste and debris.

411135 R WALL:BOND AND SET WALLS SM 17.72 Wall:Bond and set to walls 12mm thick, including additional coat or

dub out as necessary with cement and sand including all labours and remove waste and debris

411137 R WALL:BONDING AGENT IN PATCH IT 4.39 Wall:Apply bonding agent to wall in patch. 411139 R WALL:BONDING AGENT SM 4.04 Wall:Apply bonding agent to wall

Page 163: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

129 Local Space Housing

Plasterboard - Walls 411309 R WALL:FIX NE 12.5MM PLASTERBOARD SCRIM JOINTS IN PATCH IT 14.80 Wall:Supply, cut and fix ne 12.5mm plasterboard to walls in patch

including scrim joints, additional support battens, noggins etc to studding and all labours and remove waste and debris.

411311 R WALL:FIX NE 12.5MM PLASTERBOARD SCRIM JOINTS SM 12.24 Wall:Supply, cut and fix ne 12.5mm plasterboard to walls and scrim

joints, including additional support battens, noggins etc to studding and all labours and remove waste and debris.

411313 R WALL:FIX NE 12.5MM PLASTERBOARD 3MM SKIM IN PATCH IT 26.85 Wall:Supply, cut and fix ne 12.5mm plasterboard to walls in patch

including scrim joints and 3mm skim plaster, additional support battens, noggins etc. to studding, including all labours and remove waste and debris.

411315 R WALL:FIX NE 12.5MM PLASTERBOARD 3MM SKIM COAT SM 22.18 Wall:Supply, cut and fix ne 12.5mm plasterboard to walls, scrim

joints and 3mm skim plaster to walls, including additional support battens, noggins etc, to studding, including all labours and remove waste and debris.

411321 R WALL:RENEW NE 12.5MM PLASTERBOARD 3MM SKIM IN PATCH IT 37.35 Wall:Take down plasterboard or lath and plaster to wall, denail

studs etc. and prepare, supply, cut and fix ne 12.5mm plasterboard to wall in patch including scrim joints and 3mm skim plaster, additional support battens, noggins etc. to studs including all labours and remove waste and debris.

411323 R WALL:RENEW NE 12.5MM PLASTERBOARD 3MM SKIM SM 29.62 Wall:Take down plasterboard or lath and plaster to wall, denail

studs etc. and prepare, supply, cut and fix ne 12.5mm plasterboard to wall including scrim joints and 3mm skim plaster, additional support battens, noggins etc. to studs including all labours and remove waste and debris.

411325 R WALL:RENEW DOUBLE PLASTERBOARD 3MM SKIM IN PATCH IT 48.11 Wall:Take down plasterboard or lath and plaster to wall, denail

studs etc. and prepare, supply, cut and fix double layer 9.5mm plasterboard to wall in patch includingscrim joints and 3mm skim plaster, additional support battens, noggins etc. to studs including all labours and remove waste and debris.

411327 R WALL:RENEW DOUBLE PLASTERBOARD 3MM SKIM COAT SM 36.88 Wall:Take down plasterboard or lath and plaster to wall, denail

studs etc. and prepare, supply, cut and fix double layer 9.5mm plasterboard to wall includingscrim joints and 3mm skim plaster, additional support battens, noggins etc. to studs including all labours and and remove waste and debris.

Plasterwork - Ceilings 413105 R CEILING:RENEW APPLY SKIM COAT IN PATCH IT 16.07 Ceiling:Hack off existing and renew defective or apply new skim

coat of plaster in patch including all joints to existing surfaces and all labours and remove waste and debris.

Page 164: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

130 Local Space Housing

413107 R CEILING:RENEW APPLY SKIM COAT SM 13.00 Ceiling:Hack off existing and renew defective or apply new skim

coat of plaster including all joints to existing surfaces and all labours and remove waste and debris.

413109 R CEILING:BOND AND FINISH IN PATCH IT 24.82 Ceiling:Bond and finish coat to concrete ceiling in patch, apply

bonding agent, including all labours and remove waste and debris.

413111 R CEILING:BOND AND FINISH SM 21.76 Ceiling:Bond and finish coat to concrete ceiling apply bonding

agent, including all labours and remove waste and debris.

413117 R CEILING:HACK RENEW PLASTER IN PATCH IT 30.07 Ceiling:Hack off defective plaster to ceiling, prepare and replaster

ceiling in patch including bonding agent and all joints to existing surfaces and all labours and remove waste and debris.

413119 R CEILING:HACK RENEW PLASTER SM 25.70 Ceiling:Hack off defective plaster to ceiling, prepare and replaster

ceiling including bonding agent and all joints to existing surfaces and all labours and remove waste and debris.

413121 R CEILING:BONDING AGENT IN PATCH. IT 5.57 Ceiling:Apply bonding agent to ceiling in patch 413122 R CEILING:BONDING AGENT. SM 5.14 Ceiling:Apply bonding agent to ceiling Plasterboard - Ceilings 413305 R CEILING:FIX NE 12.5MM PLASTERBOARD 3MM SKIM IN PATCH IT 29.04 Ceiling:Supply, cut and fix ne 12.5mm plasterboard, scrim joints

and 3mm skim plaster to ceiling in patch including additional support battens, noggins etc.to joists, including all labours and remove waste and debris.

413307 R CEILING:FIX NE 12.5MM PLASTERBOARD 3MM SKIM COAT SM 23.49 Ceiling:Supply, cut and fix ne 12.5mm plasterboard, scrim joints

and 3mm skim plaster to ceiling, including additional support battens, noggins to joists, including all labours and remove waste and debris.

413309 R CEILING:FIX DOUBLE NE 12.5MM PLASTERBOARD IN PATCH IT 44.32 Ceiling:Supply, cut and fix double layer of ne 12.5mm plasterboard

to ceiling in patch including scrim joints and 3mm skim plaster, additional support battens, noggins to joists, including all labours and remove waste and debris.

413311 R CEILING:FIX DOUBLE NE 12.5MM PLASTERBOARD 3MM SKIM SM 35.28 Ceiling:Supply, cut and fix double layer of ne 12.5mm plasterboard

to ceiling with scrim joints and 3mm skim plaster including additional support battens, noggins etc. to joists, including all labours and remove waste and debris.

Page 165: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

131 Local Space Housing

413317 R CEILING:RENEW NE 12.5MM PLASTERBOARD SKIM IN PATCH IT 44.35 Ceiling:Take down plasterboard or lath and plaster ceiling, denail

joists and prepare, supply, cut and fix ne 12.5mm plasterboard to ceiling in patch including scrim joints and 3mm skim plaster, additional support battens, noggins etc. to joists including all labours and remove waste and debris.

413319 R CEILING:RENEW NE 12.5MM PLASTERBOARD 3MM SKIM COAT SM 35.31 Ceiling:Take down plasterboard or lath and plaster ceiling, denail

joists and prepare, supply, cut and fix ne 12.5mm plasterboard to ceiling including scrim joints and 3mm skim plaster, additional support battens, noggins etc. to joists including all labours and remove waste and debris.

413321 R CEILING:RENEW DOUBLE PLASTERBOARD SKIM IN PATCH IT 53.08 Ceiling:Take down plasterboard or lath and plaster ceiling, denail

joists and prepare, supply, cut and fix double layer ne 12.5mm plasterboard to ceiling in patch with scrim joints and 3mm skim plaster, additional support battens, noggins etc. to joists including all labours and remove waste and debris.

413323 R CEILING:RENEW DOUBLE PLASTERBOARD 3MM SKIM COAT SM 41.84 Ceiling:Take down plasterboard or lath and plaster ceiling, denail

joists and prepare, supply, cut and fix double layer ne 12.5mm plasterboard to ceiling with scrim joints and 3mm skim plaster, additional support battens, noggins etc. to joists including all labours and remove waste and debris.

413325 R CEILING:OVERLAY NE 12.5MM PLASTERBOARD 3MM SKIM SM 25.71 Ceiling:Prepare existing ceiling and overlay with ne 12.5mm

plasterboard nailed to joists including all necessary packings, battens, noggins etc to ensure line and level, scrim joints, 3mm skim plaster including all labours and remove waste and debris.

Plasterwork Repairs and Sundry Items 415001 R PLASTER REPAIR:REPAIR CRACKS AROUND FRAME LM 4.67 Plaster Repair:Repair cracks around door and window frame

including hack out loose plaster and make good with plaster including make good decorations and remove waste and debris.

415003 R PLASTER REPAIR:RENEW REVEAL TO FRAME LM 9.44 Plaster Repair:Renew plastered reveal complete to any door or

window frame including hack off defective plaster, render and set to existing, remake arris and all joints to existing, make good decorations and remove waste and debris.

415005 R PLASTER REPAIR:REPAIR CRACKS AROUND FITTING LM 3.79 Plaster Repair:Repair crack around any fitting, including hack out

loose plaster and make good with plaster.

415011 R PLASTER REPAIR:RENEW PLASTER BAND LM 8.81 Plaster Repair:Cut out defective plaster, and make good with

plaster to match existing upto 300mm wide including all joints to existing surfaces and adjacent fittings and remove waste and debris.

Page 166: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

132 Local Space Housing

415013 R PLASTER REPAIR:REPAIR CRACK TO WALL OR CEILING LM 9.12 Plaster Repair:Repair cracks to wall or ceiling plaster, cut out cracks

and apply finish plaster, trowel off flush with existing surfaces.

415015 R PLASTER REPAIR:RENEW METAL PROFILE BEAD LM 8.00 Plaster Repair:Renew any type of expanded metal profile bead in

conjunction with plasterwork repairs.

415017 R PLASTER REPAIR:MAKE GOOD AROUND PIPE ETC NO 5.61 Plaster Repair:Make good any type of plasterwork around any size

or type of pipe, projection and the like (only to be claimed where not part of schedule item for make good etc.).

415019 R PLASTER REPAIR:RENEW PLASTER VENT NO 11.55 Plaster Repair:Renew or fix new plaster vent size 225x150mm with

flyscreen including remove existing and fix new to wall incl all making good.

Sand and Cement Render 421001 R WALL:HACK OFF RENDER IN PATCH IT 21.88 Wall:Hack off any thickness of render from walls in patch, rake out

and prepare brickwork or blockwork to receive rendering and remove waste and debris.

421003 R WALL:HACK OFF RENDER SM 17.51 Wall:Hack off any thickness of render from walls, rake out and

prepare brickwork or blockwork to receive rendering and remove waste and debris.

421021 R WALL:APPLY RENDER DUB OUT IN PATCH IT 30.77 Wall:Apply 12mm cement and sand render (1:3) with waterproofing

agent to external walls in patch trowelled smooth, dub out as necessary with cement and sand including all labours and remove waste and debris.

421023 R WALL:APPLY RENDER DUB OUT SM 27.70 Wall:Apply 12mm cement and sand render (1:3) with waterproofing

agent to external walls trowelled smooth, dub out as necessary with cement and sand, including all labours and remove waste and debris.

421025 R WALL:APPLY WET DASH RENDER DUB OUT IN PATCH IT 36.44 Wall:Apply 12mm cement and sand render (1:3) with waterproofing

agent and wet dash finish to external walls in patch, dub out as necessary with cement and sand, including all labours and remove waste and debris.

421027 R WALL:APPLY WET DASH RENDER DUB OUT SM 33.81 Wall:Apply 12mm cement and sand render (1:3) with waterproofing

agent and wet dash finish to external walls, dub out as necessary with cement and sand, including all labours and remove waste and debris.

421029 R WALL:APPLY DRY DASH RENDER DUB OUT IN PATCH IT 43.09 Wall:Apply 12mm cement and sand render (1:3) with waterproofing

agent and dry dash finish to external walls in patch, dub out as necessary with cement and sand, including all labours and remove waste and debris.

Page 167: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

133 Local Space Housing

421031 R WALL:APPLY DRY DASH RENDER DUB OUT SM 39.06 Wall:Apply 12mm cement and sand render (1:3) with waterproofing

agent and dry dash finish to external walls, dub out as necessary with cement and sand, including all labours and remove waste and debris.

421033 R WALL:APPLY DECORATIVE RENDER DUB IN PATCH IT 45.62 Wall:Apply 12mm cement and sand render (1:3) with waterproofing

agent to external walls in patch including ‘Decorative’ finish, dub out as necessary with cement and sand, including all labours and remove waste and debris.

421035 R WALL:APPLY DECORATIVE RENDER DUB SM 41.24 Wall:Apply 12mm cement and sand render (1:3) with waterproofing

agent to external walls including ‘Decorative’ finish, dub out as necessary with cement and sand and all labours and remove waste and debris.

Render Repairs and Sundry Items 423001 R RENDER REPAIRS:REPAIR CRACK LM 9.48 Render Repairs:Repair crack in any external render including

carefully hack out and make good with cement and sand including applying finish to match existing.

423003 R RENDER REPAIRS:REPAIR CRACK AROUND FRAME LM 12.75 Render Repairs:Repair cracks to render and applied finishes around

door or window frame including hack out loose render and make good including make good sealant joint to frame.

423005 R RENDER REPAIRS:RENEW REVEAL TO FRAME LM 15.16 Render Repairs:Renew rendered door or window frame reveal

complete including hack off external finish, remake arris and rerender including any dubbing out and waterproofing agent and make good applied finishes and and remove waste and debris.

423007 R RENDER REPAIRS:RENEW BELLCAST FEATURE LM 14.92 Render Repairs:Renew bellcast to any render over openings or

above dampcourse, hack off, fix bellcast bead and form bellcast externally and and remove waste and debris.

Coatings to Ceilings 425001 R CEILING:APPLY ARTEX TYPE FINISH SM 11.17 Ceiling:Prepare and apply Artex type textured coating with stipple

or comb finish to ceiling including caulk joints in plasterboard and or cracks in plaster finish.

425002 R CEILING:APPLY ARTEX TYPE FINISH IN PATCH IT 9.42 Ceiling:Prepare and apply Artex type textured coating with stipple

or comb finish to ceiling in patch including caulk joints in plasterboard and or cracks in plaster finish, prime as necessary and make good to match existing.

Page 168: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

134 Local Space Housing

Dry Lining 427003 R WALL:DRY LINE NE 12.5MM PLASTERBOARD PADS AND DABS SM 33.27 Wall:Strip existing wall, thoroughly clean down mould and fungi

from any affected areas, remove any coving and line wall with ne 12.5mm plasterboard fixed to plaster pads and dabs in accordance with manufacturers directions including all filling and jointing, disconnect, remove and refix on re-aligned boxes with extended fixing screws any socket outlets, switch plates and the like, remove and later refix all skirtings, dado rails and the like and make good on completion and remove waste and debris.

427005 R CEILING:DRY LINE 12.5MM THERMALBOARD SM 64.93 Ceiling:Strip existing ceiling, thoroughly clean down mould and

fungi from affected areas, remove any coving, supply and fix 50x25mm treated softwood battens at 600mm centres including any necessary packing, plugging and screwing, line ceilings with 12.5mm plasterboard faced thermal board screwed to battens including filling and jointing, disconnect and remove ceiling roses and refix on re-aligned boxes and fit extended fixing fixing screws and remove waste and debris.

427007 R CEILING:DRY LINE 25MM THERMALBOARD SM 86.34 Ceiling:Strip existing ceiling, thoroughly clean down mould and

fungi from affected areas, remove any coving, supply and fix 50x25mm treated softwood battens at 600mm centres including any necessary packing, plugging and screwing, line ceilings with 25mm plasterboard faced thermal board screwed to battens including filling and jointing, disconnect and remove ceiling roses and refix on re-aligned boxes and fit extended fixing screws and remove waste and debris.

427009 R WALL:DRY LINE 25MM THERMALBOARD SM 62.20 Wall:Strip existing walls, thoroughly clean down mould and fungi

from affected areas, remove and later refix all skirtings, dado rails and the like, line walls with 25mm nominal plasterboard faced thermal board solidly adhered to background in accordance with manufacturers directions including filling and jointing, disconnect and remove socket outlets and or switches and refix on re-aligned boxes and fit extended fixing screws and remove waste and debris.

427011 R WALL:DRY LINE 45MM THERMALBOARD SM 80.10 Wall:Strip existing walls, thoroughly clean down mould and fungi

from affected areas, remove and later refix all skirtings, dado rails and the like, line walls with 45mm nominal plasterboard faced thermal board solidly adhered to background in accordance with manufacturers directions including filling and jointing, disconnect and remove socket outlets and or switches and refix on re-aligned boxes and fit extended fixing screws and and remove waste and debris.

Plaster Coving 429001 R COVING:FIX PLASTER COVING LM 8.39 Coving:Supply and fix new Gyproc plaster coving ne 150mm girth. 429003 R COVING:REFIX PLASTER COVING LM 6.85 Coving:Remove, set aside and refix Gyproc plaster coving ne

150mm girth.

Page 169: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

135 Local Space Housing

Floor Screeds 431301 R SCREED:HACK UP SCREED IN PATCH IT 26.26 Screed:Hack up any thickness of floor screed in patch and remove

waste and debris.

431303 R SCREED:HACK UP SCREED SM 19.70 Screed:Hack up any thickness of floor screed and remove waste

and debris.

431305 R SCREED:REPAIR CRACK IN FLOOR LM 7.04 Screed:Repair crack in floor screed ne 50mm wide with cement and

sand including cutting out to form key and infill to match existing.

431307 R SCREED:LAY 40MM THICK IN PATCH IT 30.56 Screed:Lay cement and sand floor screed in patch, ne 40mm thick,

trowel smooth for floor finish, clean off, grout sub-base with cement slurry, apply liquid damp proof membrane and remove waste and debris.

431309 R SCREED:LAY 40MM THICK SCREED SM 26.18 Screed:Lay cement and sand floor screed ne 40mm thick, trowel

smooth for floor finish, clean off, grout sub-base with cement slurry, apply liquid damp proof membrane and remove waste and debris.

431311 R SCREED:OVERLAY WITH CONCRETE NE 65MM SM 23.09 Screed:Overlay any sub-base with fine concrete (1:2:4), ne 65mm

thick including clean off sub- base, tamp level to receive floor screed and remove waste and debris.

431315 R SCREED:LATEX SELF LEVEL SM 17.03 Screed:Lay latex self levelling screed.

Page 170: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

136 Local Space Housing

WALL AND FLOOR TILE AND SHEET FINISHES Wall and Floor Finishes Wall Tiling 431003 R WALL TILES:HACK OFF AND MAKE GOOD SM 11.08 Wall Tiles:Hack off glazed wall tiling in patch, make good bed and

remove waste and debris.

431005 R WALL TILES:RENEW OR FIX INDIVIDUAL NEW GLAZED TILE NO 1.76 Wall Tiles:Clean off walls and prepare to receive new tile, supply

and fix new ne 152x152x6mm glazed ceramic wall tile in patch to splashbacks and cills including fixing with adhesive, grouting and any necessary cutting including hack off glazed wall tiling in patch as necessary, make good bed and remove waste and debris. (per tile).

431007 R WALL TILES:RENEW OR FIX NEW GLAZED TILES SM 51.56 Wall Tiles:Clean off walls and prepare to receive new tiles, supply

and fix new ne 152x152x6mm glazed ceramic wall tiles to splashback and cills, including fixing with adhesive, grouting, and any necessary cutting including hack off glazed wall tiling, make good bed and remove waste and debris.

431011 R WALL TILES:RENEW TO CILL LM 20.22 Wall Tiles:Hack off tiles to cill, clear away, supply and lay new ne

152x152x6mm glazed tiles to cill, ne 150mm wide, bed in mortar or adhesive including make good to bed, grout and all necessary cutting and forming straight edge and remove waste and debris.

431013 R WALL TILES:NEW SPLASHBACK TO BASIN IT 18.03 Wall Tiles:Clean off wall, and prepare to receive new tiles, and

supply and fix new ne 152x152x6mm glazed ceramic tiles to 750x300mm splashback to wash hand basin including fixing with adhesive, grouting, and any cutting and remove waste and debris.

431015 R WALL TILES:NEW SPLASHBACK TO BATH LM 17.01 Wall Tiles:Clean off wall and prepare to receive new tiles, and

supply and fix new ne 152x152x6mm glazed ceramic wall tiles in 300mm high splashback to side and end of bath, including fixing with adhesive, grouting, and any cutting and remove waste and debris.

431017 R WALL TILES:NEW SPLASHBACK TO SINK LM 17.90 Wall Tiles:Clean off wall, and prepare to receive new tiles, and

supply and fix new ne 152x152x6mm glazed ceramic wall tiles in 300mm high to splashback to sink and worktops, including fixing with adhesive, grouting, and any cutting and remove waste and debris.

431019 R WALL TILES:NEW REVEALS NE 150MM WIDE LM 13.68 Wall Tiles:Clean off wall and prepare to receive new tiles, supply

and fix new ne 152x152x6mm glazed ceramic wall tiles to reveals ne 150mm wide, including fixing with adhesive, grouting and any cutting and remove waste and debris.

Page 171: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

137 Local Space Housing

431021 R WALL TILES:REMOVE AND REFIX PER TILE NO 1.05 Wall Tiles:Take off existing wall tile to patch and set aside, clean off

and refix to walls with adhesive, make good to bed and grout including all necessary cutting and remove waste and debris (per tile).

431023 R WALL TILES:REMOVE AND REFIX SM 60.14 Wall Tiles:Take off existing wall tiles and set aside, clean off and

refix to walls with adhesive, make good to bed and grout including all necessary cutting and remove waste and debris.

431025 R WALL TILES:RAKE OUT AND REGROUT SM 11.76 Wall Tiles:Rake out and regrout wall tiling and remove waste and

debris.

431041 R WALL TILES:NEW GLAZED TILES TO KITCHEN SM 56.81 Wall Tiles:Clean off walls and prepare to receive new tiles, supply

and fix new ne 152x152x6mm glazed coloured ceramic wall tiles to kitchen worktop, splashback cooker space and cills, including fixing with adhesive, grouting, and any necessary cutting, sealing around worktop and sink top with silicone sealant and remove waste and debris.

431043 R WALL TILES:NEW GLAZED TILES TO BATHROOM SM 56.81 Wall Tiles:Clean off walls and prepare to receive new tiles, supply

and fix new ne 152x152x6mm glazed coloured ceramic wall tiles to bathroom, splash-back and cills, including fixing with adhesive, grouting, and any necessary cutting, sealing around sanitary fittings with silicone sealant and remove waste and debris.

Floor Tiles - Quarry Tiles 431501 R FLOOR TILES:RENEW QUARRY TILE IN PATCH IT 107.45 Floor Tiles:Hack off quarry tiles, clear away, supply and lay new ne

152x152x17mm quarry floor tiles in patch ne 1.00sm on and including cement and sand bed, grout in tiles and all necessary cutting and remove waste and debris.

431503 R FLOOR TILES:RENEW QUARRY TILES SM 97.78 Floor Tiles:Hack off quarry tiles, clear away, supply and lay new ne

152x152x17mm quarry tiles, on and including cement and sand bed, grout in tiles, and all necessary cutting and remove waste and debris.

431505 R FLOOR TILES:NEW QUARRY TILE IN PATCH IT 75.50 Floor Tiles:Supply and lay new ne 152x152x17mm quarry floor tiles

in patch ne 1.00sm on and including cement and sand bed, grout in tiles and all necessary cutting and remove waste and debris.

431507 R FLOOR TILES:NEW QUARRY TILES SM 75.02 Floor Tiles:Supply and lay new ne 152x152x17mm quarry floor tiles

on and including cement and sand bed, grout in tiles and all necessary cutting and remove waste and debris.

Page 172: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

138 Local Space Housing

431509 R FLOOR TILES:REBED QUARRY PER TILE NO 1.90 Floor Tiles:Take up loose quarry floor tile in patch ne 1.00sm and

set aside, clean off floor and tile, refix tile and grout in and remove waste and debris (per tile).

431513 R FLOOR TILES:RENEW QUARRY PER TILE NO 2.64 Floor Tiles:Hack up individual quarry tiles, clear away, supply and lay new

ne 152x152x17mm quarry floor tile in individual tile replacement on and including cement and sand bed, grout in tile and all necessary cutting and remove waste and debris. (per tile)

431511 R FLOOR TILES:REBED QUARRY TILES SM 71.51 Floor Tiles:Take up loose quarry floor tile and set aside, clean off

floor and tiles, refix tiles and grout in and remove waste and debris.

Skirtings - Quarry Tiles 431701 R TILE SKIRTING:RENEW QUARRY TILES IN PATCH NO 4.93 Tile Skirting:Hack off quarry tile skirting, clear away, supply and lay

new ne 152mm quarry tile skirting with rounded top edge and cove at bottom, on cement and sand backing, grout in tile and all necessary cutting, angles and ends, lengths ne 1.00m and remove waste and debris. (per tile).

431703 R TILE SKIRTING:RENEW QUARRY TILES LM 21.14 Tile Skirting:Hack off quarry tile skirting, clear away, supply and lay

new ne 152mm quarry tile skirting with rounded top and cove at bottom, on cement and sand backing, grout in tiles, and all necessary cutting, angles and ends and remove waste and debris.

431705 R TILE SKIRTING:LAY NEW INDIVIDUAL QUARRY TILE NO 4.05 Tile Skirting:Supply and lay new ne 152mm quarry tile skirting with

rounded top edge and cove at bottom, on cement and sand backing, grout in tiles and all necessary cutting, angles and ends, lengths ne 1.00m and remove waste and debris. (per tile).

431707 R TILE SKIRTING:LAY NEW QUARRY TILES LM 16.76 Tile Skirting:Supply and lay new ne 152mm quarry tile skirting with

rounded top edge and cove at bottom, on cement and sand backing, grout in tiles and all necessary cutting, angles and ends and remove waste and debris.

431709 R TILE SKIRTING:REBED INDIVIDUAL QUARRY TILE NO 5.40 Tile Skirting:Take off loose quarry tile skirting and set aside, clean

tile and prepare backing, rebed tile in cement and sand, grout in tile, in lengths ne 1.00m and remove waste and debris. (per tile).

431711 R TILE SKIRTING:REBED QUARRY TILES LM 22.18 Tile Skirting:Take off loose quarry tile skirting and set aside, clean

tile and prepare backing, rebed tile in cement and sand and grout in tile and remove waste and debris..

Floor Tiles - Ceramic Tiles 431901 R FLOOR TILES:RENEW CERAMIC TILES IN PATCH IT 91.13 Floor Tile:Hack off ceramic tiles, clear away, supply and lay new ne

300x300x12mm ceramic floor tiles in patch on and including cement and sand bed, grout in tiles and all necessary cutting and remove waste and debris.

Page 173: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

139 Local Space Housing

431903 R FLOOR TILES:RENEW CERAMIC TILES SM 94.31 Floor Tiles:Hack off ceramic tiles, clear away, supply and lay new

ne 300x300x12mm ceramic floor tiles on and including cement and sand bed, grout in tiles and all necessary cutting and remove waste and debris.

431905 R FLOOR TILES:NEW CERAMIC TILES IN PATCH IT 58.31 Floor Tiles:Supply and lay new ne 300x300x12mm ceramic floor

tiles in patch on and including cement and sand bed, grout in tiles and all necessary cutting and remove waste and debris.

431907 R FLOOR TILES:NEW CERAMIC TILES SM 70.24 Floor Tiles:Supply and lay new ne 300x300x12mm ceramic floor

tiles on and including cement and sand bed, grout in tiles and all necessary cutting and remove waste and debris..

431909 R FLOOR TILES:REBED CERAMIC TILES IN PATCH-PER TILE NO 1.43 Floor Tiles:Take up loose ceramic floor tile to patch and set aside,

clean off floor and tile, refix tile and grout in and remove waste and debris. (per tile).

431911 R FLOOR TILES:REBED CERAMIC TILES SM 60.05 Floor Tiles:Take up loose ceramic floor tiles and set aside, clean off

floor and tiles, refix tiles and grout in and remove waste and debris.

Skirtings - Ceramic 432101 R TILE SKIRTING:RENEW INDIVIDUAL CERAMIC TILE NO 3.95 Tile Skirting:Hack off ceramic tile skirting, clear away, supply and

lay new ne 152mm ceramic tile skirting with rounded top edge on cement and sand backing, grout in tile and all necessary cutting, angles and ends, lengths ne 1.00m and remove waste and debris. (per tile).

432103 R TILE SKIRTING:RENEW CERAMIC TILES LM 17.02 Tile Skirting:Hack off ceramic tile skirting, clear away, supply and

lay new ne 152mm ceramic tile skirting with rounded top edge on cement and sand backing, grout in tiles and all necessary cutting, angles and ends and remove waste and debris.

432105 R TILE SKIRTING:LAY NEW INDIVIDUAL CERAMIC TILE NO 3.51 Tile Skirting:Supply and lay new ne 152mm ceramic tile skirting

with rounded top edge on cement and sand backing, grout in tile and all necessary cutting angles and ends, lengths ne 1.00m and remove waste and debris. (per tile).

432107 R TILE SKIRTING:LAY NEW CERAMIC TILES LM 13.52 Tile Skirting:Supply and lay new ne 152mm ceramic tile skirting

with rounded top edge on cement and sand backing, grout in tiles and all necessary cutting angles and ends and remove waste and debris.

432109 R TILE SKIRTING:REBED SINGLE CERAMIC TILE - PER TILE NO 4.49 Tile Skirting:Take off loose ceramic tile skirting and set aside, clean

tile and prepare backing, rebed tile in cement and sand, grout in tile in lengths ne 1.00m and remove waste and debris (per tile).

Page 174: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

140 Local Space Housing

432111 R TILE SKIRTING:REBED CERAMIC TILES LM 18.32 Tile Skirting:Take off loose ceramic tile skirting and set aside, clean

tiles and prepare backing, rebed tiles in cement and sand and grout in tiles.

Floor Tiles - Vinyl 432301 R FLOOR TILES:HACK UP SINGLE VINYL TILE PER TILE NO 0.93 Floor Tiles:Hack off vinyl floor tiles in patch, make good bed under

(per tile) and remove waste and debris.

432303 R FLOOR TILES:HACK UP VINYL TILES SM 7.20 Floor Tiles:Hack off vinyl floor tiles, including make good bed under

and remove waste and debris.

432305 R FLOOR TILES:RENEW INDIVIDUAL VINYL TILE PER TILE NO 2.82 Floor Tiles:Take up individual vinyl floor tiles, supply and lay new

ne 300x300x2.00mm vinyl tiles with adhesive in patch including all necessary cutting of tiles and clean off and remove waste and debris (per tile).

432307 R FLOOR TILES:RENEW VINYL TILES SM 27.14 Floor Tiles:Hack off vinyl floor tiles, supply and lay new ne

300x300x2.00mm vinyl tiles with adhesive in patch including all necessary cutting of tiles and clean off and remove waste and debris.

432309 R FLOOR TILES:RENEW VINYL TILES AND SUB-BASE SM 42.97 Floor Tiles:Hack off vinyl floor tiles, supply and lay new ne

300x300x2.00mm vinyl floor tiles with adhesive to and including supply and lay approved sheet sub base including all cutting, labours and clean off and remove waste and debris.

432311 R FLOOR TILES:LAY NEW INDIVIDUAL VINYL TILE PER TILE NO 2.38 Floor Tiles:Supply and lay new ne 300x300x2.00mm vinyl floor tiles

with adhesive in patch including all necessary cutting of tiles and clean off (per tile) and remove waste and debris.

432313 R FLOOR TILES:LAY NEW VINYL TILES SM 22.76 Floor Tiles:Supply and lay new ne 300x300x2.00mm vinyl floor tiles

with adhesive including all necessary cutting of tiles and clean off and remove waste and debris.

432314 R FLOOR TILE:LAY NEW VINYL TILES AND SUB-BASE SM 36.87 Floor Tiles:Supply and lay new ne 300x300x2.00mm vinyl floor tiles

with adhesive to and including approved sheet sub base including all cutting, labours and clean off and remove waste and debris.

432315 R FLOOR TILES:REFIX INDIVIDUAL VINYL TILE NO 2.31 Floor Tile:Take up existing loose vinyl floor tiles in patch and set

aside, clean off tiles and bed and refix tiles with adhesive and clean off (per tile) and remove waste and debris.

432317 R FLOOR TILES:REFIX VINYL TILES SM 20.95 Floor Tiles:Take up existing loose vinyl floor tiles, set aside, clean

off tiles and bed and refix tiles with adhesive and clean off and remove waste and debris.

Page 175: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

141 Local Space Housing

Sheet Flooring 432501 R SHEET FLOORING:RENEW VINYL SM 35.46 Flooring:Take up any covering, clear away, supply and lay minimum

2.0mm felt backed vinyl sheet flooring with adhesive to cement and sand screed, or hardboard including all necessary cutting, all labours and clean off, and remove waste and debris.

432503 R SHEET FLOORING:RENEW VINYL AND SUB-BASE SM 49.10 Sheet Flooring:Take up any covering, clear away, supply and lay

minimum 2.0mm felt backed vinyl sheet flooring with adhesive to and including supply and lay approved sheet sub base, all necessary cutting, all labours, and clean off, and remove waste and debris.

432505 R SHEET FLOORING:LAY NEW VINYL SM 31.09 Sheet Flooring:Supply and lay minimum 2.0mm felt backed vinyl

sheet flooring with adhesive to cement and sand screed or hardboard including all necessary cutting, all labours and clean off, and remove waste and debris.

432507 R SHEET FLOORING:LAY NEW VINYL AND SUB-BASE SM 44.73 Sheet Flooring:Supply and lay minimum 2.0mm felt backed vinyl

sheet flooring with adhesive to and including supply and lay approved sheet sub base including all necessary cutting, all labours and clean off, and remove waste and debris.

432509 R SHEET FLOORING:REFIX FLOORING SM 10.85 Sheet Flooring:Take up any type of existing loose sheet flooring,

clean off flooring and bed under and refix flooring with adhesive and clean off, and remove waste and debris.

'Polysafe' Flooring 432601 R SHEET FLOORING:RENEW POLYSAFE SM 42.03 Flooring:Take up any covering, clear away, supply and lay 'Polysafe'

or other equal and approved proprietary safety flooring with adhesive to cement and sand screed or hardboard or plywood including all necessary cutting, all labours, upstands and clean off, and remove waste and debris.

432603 R SHEET FLOORING:RENEW POLYSAFE AND SUB-BASE SM 55.67 Flooring:Take up any covering, clear away, supply and lay 'Polysafe'

or other equal and approved proprietary safety flooring with adhesive to and including supply and lay approved sheet sub base, including all necessary cutting, all labours, upstands and clean off, and remove waste and debris.

432605 R SHEET FLOORING:LAY NEW POLYSAFE SM 37.66 Sheet Flooring:Supply and lay 'Polysafe' or other equal and

approved proprietary safety flooring with adhesive to cement and sand screed or hardboard plywood including all necessary cutting, all labours, upstands and clean off, and remove waste and debris.

432607 R SHEET FLOORING:LAY NEW POLYSAFE AND SUB-BASE SM 51.30 Sheet Flooring:Supply and lay 'Polysafe' or other equal and

approved proprietary safety flooring with adhesive to and including supply and lay approved sheet sub base, including all necessary cutting, all labours, upstands and clean off, and remove waste and debris.

Page 176: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

142 Local Space Housing

432609 R SHEET FLOORING:RENEW POLYSAFE TO STAIRCASE SM 50.79 Flooring:Take up any covering, clear away, supply and lay 'Polysafe' or

other equal and approved proprietary safety flooring with adhesive to cement and sand screed or concrete treads, risers and landings of staircase including all necessary cutting, all labours, upstands and clean off, and remove waste and debris.

432611 R SHEET FLOORING:LAY NEW POLYSAFE TO STAIRCASE SM 44.22 Sheet Flooring:Supply and lay 'Polysafe' or other equal and approved

proprietary safety flooring with adhesive to cement and sand screed or concrete treads, risers and landings of staircase including all necessary cutting, all labours, upstands and clean off, and remove waste and debris.

432617 R SHEET FLOORING:REFIX POLYSAFE SM 9.77 Sheet Flooring:Take up any type of existing loose ‘Polysafe’ or other

proprietary non-slip sheet flooring, clean off flooring and bed under and refix flooring with adhesive including all necessary cutting, all labours, upstands and clean off, and remove waste and debris.

432604 R SHEET FLOORING:RENEW NON-SLIP AND SUB-BASE SM 51.76 Sheet Flooring:Take up any covering, clear away, supply and lay

any type of approved non-slip vinyl sheet safety flooring with adhesive to and including supply and lay approved sheet sub base, including all necessary cutting, all labours, upstands and clean off, clear silicone sealant jointing at all perimeters, and remove waste and debris..

432608 R SHEET FLOORING:LAY NEW NON-SLIP AND SUB-BASE SM 48.70 Sheet Flooring:Supply and lay any type of approved non-slip vinyl

sheet safety flooring with adhesive to and including supply and lay approved sheet sub base including all necessary cutting, all labours, upstands and clean off, clear silicone sealant jointing at all perimeters, and remove waste and debris..

432613 R SHEET FLOORING:LAY NEW NON-SLIP SM 37.66 Sheet Flooring:Supply and lay any type of approved non-slip vinyl sheet

safety flooring with adhesive to cement and sand screed including all necessary cutting, all labours, upstands and clean off, and remove waste and debris.

432615 R SHEET FLOORING:LAY NEW NON-SLIP TO STAIRCASE SM 44.22 Sheet Flooring:Supply and lay any type of approved non-slip vinyl sheet

safety flooring with adhesive to cement and sand screed or concrete treads, risers and landings of staircase including all necessary cutting, all labours, upstands and clean off, and remove waste and debris.

Skirtings - Plastic, Vinyl, Lino or Rubber 432701 R SKIRTING:RENEW VINYL ETC NE 1.0LM IT 9.03 Skirting:Renew or fix new plastic vinyl lino or rubber skirting

including remove existing as necessary, fix new with adhesive including all cutting and labours in lengths ne 1.00m, and remove waste and debris.

432703 R SKIRTING:RENEW VINYL ETC OVER 1.0M LM 11.47 Skirting:Renew or fix new plastic, vinyl, lino or rubber skirting

including remove existing as necessary, fix new with adhesive including all cutting and labours, and remove waste and debris.

Page 177: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

143 Local Space Housing

432705 R SKIRTING:REFIX VINYL ETC NE 1.0LM IT 7.24 Skirting:Refix loose plastic, vinyl, lino or rubber skirting including

remove existing as necessary, refix with adhesive including all labours in lengths ne 1.00m, and remove waste and debris.

432707 R SKIRTING:REFIX VINYL ETC OVER 1.0M LM 9.07 Skirting:Refix loose plastic, vinyl, lino or rubber skirting including

remove existing as necessary, refix with adhesive including all labours, and remove waste and debris.

Contract Grade Carpeting 432801 R CARPET:RENEW TO COMMUNAL AREAS SM 14.70 Carpet:Renew tight woven heavy contract grade carpet to

communal areas, take up existing and dispose to tip, prepare sub-base, secure all edges with gripper or proprietary adhesive tape, cut and fit around pipes, into alcoves, door openings and the like including all necessary door strips etc., and remove waste and debris

432803 R CARPET:RENEW TO COMMUNAL AREAS UNDERLAY SM 18.38 Carpet:Renew tight woven heavy contract grade carpet to

communal areas, take up existing and dispose to tip, prepare sub-base, lay underlay secure all edges with gripper or proprietary adhesive tape, cut and fit around pipes, into alcoves, door openings and the like including all necessary door strips etc., and remove waste and debris

432805 R CARPET:RENEW TO DOMESTIC AREAS SM 17.06 Carpet:Renew tight woven medium contract grade carpet to

domestic areas, take up existing and dispose to tip, prepare sub-base, lay underlay secure all edges with gripper or proprietary adhesive tape, cut and fit around pipes, into alcoves, door openings and the like including all necessary door strips etc., and remove waste and debris.

Nosings 432901 R NOSING:RENEW NOSING TO STEP NO 45.74 Nosing:Renew any size or type of proprietary alloy nosing to step

including drilling and plugging as necessary, and remove waste and debris.

432903 R NOSING:SUPPLY AND FIX NOSING TO STEP NO 41.37 Nosing:Supply and fix any size or type of proprietary alloy nosing to

step including all necessary drilling and plugging, and remove waste and debris.

432905 R NOSING:REFIX TO STEP NO 13.42 Nosing:Take off and refix any size or type of nosing to step

including drilling and plugging as necessary.

Page 178: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

144 Local Space Housing

PAINTING AND DECORATING Preparation - External and Internal Works Prior to Painting 435021 R GUTTER:CLEAN OUT PRIOR TO DECORATION LM 2.19 Gutter:Clean out eaves gutter prior to redecoration including flush

out and test, and remove waste and debris.

Preparation - General Surfaces 435101 R SURFACE:STRIP BACK SURFACES OVER 300MM SM 9.55 Surface:Apply paint remover, strip off paint to surfaces in

accordance with manufacturers directions or using cyclone stripper, or burn off, or scrape off, wire brush, prepare and bring forward general surfaces over 300mm girth for redecoration, and remove waste and debris.

435103 R SURFACE:STRIP BACK SURFACES NE 300MM LM 3.30 Surface:Apply paint remover, strip off paint to surfaces in

accordance with manufacturers directions or using cyclone stripper, or burn off, or scrape off, wire brush, prepare and bring forward general surfaces ne 300mm girth for redecoration, and remove waste and debris.

435113 R SURFACE:STRIP BACK WINDOWS SM 19.97 Surfaces:Apply paint remover, strip off paint to general surfaces of

windows in accordance with manufacturers directions or using cyclone stripper, or burn off, or scrape off, wire brush, prepare and bring forward general surfaces for redecoration, including all beads, edges, rebates, opening edges and the like, and remove waste and debris

435119 R SEALER:APPLY ONE COAT TO WALLS AND CEILINGS SM 4.99 Sealer:Prepare and apply one coat of sealer stabilizer to walls or

ceilings in accordance with manufacturers directions.

435121 R STAIN BLOCK:APPLY ONE COAT SM 6.27 Stain Block:Apply one coat of stain block to plastered ceiling strictly in

accordance with the manufacturers instructions.

Preparation - External Walls 435301 R WALLS:BRUSH AND WASH DOWN SM 2.33 Walls:Brush or scrape and wire brush and wash down painted

surfaces of walls to remove grime or soot or to remove flaking paint from walls.

External Decoration Masonry [Smooth or Textured] Paint - External Walls 436051 R SOFFIT:WASH APPLY 2 COATS SMOOTH MASONRY PAINT SM 10.84 Soffit:Wash down, fill in cracks and holes, sand smooth and apply two

coats of smooth or textured masonry paint to rendered or concrete canopies or soffits.

Page 179: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

145 Local Space Housing

436053 R SOFFITS:WASH APPLY SEALER 2 COATS MASONRY PAINT SM 12.32 Soffit:Wash down, fill in cracks and holes, sand smooth and apply one

coat of sealer and two coats of smooth or textured masonry paint to rendered or concrete soffits.

436061 R WALLS:WASH APPLY 2 COATS MASONRY PAINT SM 10.84 Walls:Wash down, fill in cracks and holes, sand smooth and apply two

coats of smooth or textured masonry paint to rendered or concrete surfaces of walls.

436063 R WALLS:WASH APPLY SEALER 2 COATS MASONRY PAINT SM 12.32 Walls:Wash down, fill in cracks and holes, sand smooth and apply one

coat of sealer, two coats of smooth or textured masonry paint to rendered or concrete surfaces of walls.

436071 R WALLS:APPLY 2 COATS MASONRY PAINT SM 10.84 Walls:Prepare and apply two coats smooth or textured masonry paint to

external rendered surfaces of walls.

436072 R WALLS:APPLY 2 COATS MASONRY PAINT - BRICK SM 11.71 Walls:Prepare and apply two coats smooth or textured masonry paint to

brickwork or concrete surfaces of walls.

436073 R WALLS:WASH APPLY 2 COATS MASONRY PAINT - RENDER SM 12.59 Walls:Wash down, fill in cracks and holes, sand down and apply two coats

of smooth or textured masonry paint to rendered or concrete walls.

436074 R WALLS:WASH APPLY 2 COATS MASONRY PAINT - BRICK SM 13.46 Walls:Wash down, fill in cracks and holes, sand down and apply two coats

of smooth or textured masonry paint to brickwork surfaces of walls.

436081 R WALLS:APPLY SEALER 2 COATS MASONRY - RENDER SM 12.32 Walls:Prepare and apply one coat of stabilising solution and two coats

smooth or textured masonry paint to external rendered surfaces of walls.

436082 R WALLS:APPLY SEALER 2 COATS MASONRY - BRICK SM 12.59 Walls:Prepare and apply one coat of stabilising solution and two coats

smooth or textured masonry paint to brickwork or concrete surfaces of walls.

436083 R WALLS:WASH APPLY SEALER 2 COATS MASONRY - RENDER SM 14.51 Walls:Wash down, fill in cracks and holes, sand down and apply one coat

of stabilising solution and two coats of smooth or textured masonry paint to rendered or concrete walls.

436084 R WALLS:WASH APPLY SEALER 2 COATS MASONRY - BRICK SM 15.39 Walls:Wash down, fill in cracks and holes, sand down and apply one coat

of stabilising solution and two coats of smooth or textured masonry paint to brickwork surfaces of walls.

Oil Paint - External Metalwork 436201 R GARAGE DOOR:PREPARE PRIME PAINT 2 GLOSS IT 98.91 Door:Rub down prepare, apply coat of primer, one undercoat, two

coats of gloss paint on external surfaces of up and over metal garage door (one side and edges).

Page 180: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

146 Local Space Housing

436203 R DOOR FRAME:PREPARE PAINT 2 GLOSS NE 300MM LM 6.76 Door Frame:Rub down, prepare, apply coat of primer, one

undercoat, two coats of gloss paint on external surfaces of metal frames ne 300mm girth.

436205 R DOOR:PREPARE PRIME PAINT 2 GLOSS METAL DOOR IT 62.68 Door:Rub down, prepare for and apply one coat of primer, one

undercoat and two coats of gloss paint on any size single metal door (both sides and edges).

436207 R DOOR:PREPARE PRIME PAINT 2 GLOSS METAL GLAZED IT 74.31 Door:Rub down, prepare for and apply one coat of primer, one

undercoat and two coats of gloss paint on any size single glazed metal door (both sides and edges).

436209 R WINDOW:PREPARE PRIME PAINT2 GLOSS METAL SM 24.73 Window:Rub down, prepare for and apply a coat of primer, one

undercoat, and two coats of gloss paint on surface of metal window (one side and edges).

436215 R GATES:PREPARE PRIME PAINT GATE AND POSTS IT 28.84 Gates:Wire brush, prepare for, and apply one coat primer, one

undercoat, two coats of gloss paint to both sides of any size type single metal gate including all edges and all surfaces of posts.

436217 R BALUSTRADING:PREPARE PRIME PAINT SURFACES SM 27.18 Balustrading:Wire brush, prepare for and apply one coat of primer,

one undercoat, two coats of gloss paint on ornamental metal balustrading, railings or gates (measured both sides).

436219 R STAIRCASE:PREPARE PRIME PAINT METAL STAIRS SM 26.60 Staircase:Wire brush, prepare for and apply one coat of primer, one

undercoat, two coats of gloss paint on metal staircase, strings, handrail balustrading (measured both sides).

436221 R GUTTER:PREPARE PRIME PAINT EAVES GUTTER LM 3.43 Gutter:Wire brush, prepare and apply coat of primer, one undercoat

and two coats of gloss paint to outside of eaves gutter including brackets.

436223 R PIPEWORK:PREPARE PRIME PAINT NE 300MM LM 2.94 Pipework:Wire brush, prepare for and apply coat of primer, one

undercoat, and two coats of gloss paint to external pipework ne 300mm girth including brackets.

Metalshield Paint - External Metalwork 436601 R GARAGE DOOR:PREPARE PRIME METALSHIELD IT 91.36 Garage Door:Rub down prepare, apply coat of primer, two coats of

metalshield paint on external surfaces of up and over metal garage door (one side and edges).

436603 R DOOR FRAME:PREPARE PRIME METALSHIELD NE 300MM LM 7.29 Door Frame:Rub down, prepare, apply coat of primer, two coats of

metalshield paint on external surfaces of metal frames ne 300mm girth.

436605 R DOOR:PREPARE PRIME METALSHIELD METAL IT 65.49 Door:Rub down, prepare for and apply one coat of primer, two coats of

metalshield paint on any size single metal door (both sides and edges).

Page 181: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

147 Local Space Housing

436607 R DOOR:PREPARE PRIME METALSHIELD METAL GLAZED IT 76.31 Garage Door:Rub down, prepare for and apply one coat of primer, two

coats of metalshield paint on any size single glazed metal door (both sides and edges).

436609 R WINDOW:PREPARE METALSHIELD METAL SM 26.47 Window:Rub down, prepare for and apply a coat of primer, two coats of

metalshield paint on surface of metal window (one side and edges).

436615 R GATES:PREPARE PRIME METALSHIELD GATE AND POSTS IT 32.17 Gates:Wire brush, prepare for, and apply one coat primer, two coats of

metalshield paint to both sides of any size type single metal gate including all edges and all surfaces of posts.

436617 R RAILINGS-ORNAMENTAL:PRIME METALSHIELD SURFACES SM 30.79 Balustrading:Wire brush, prepare for and apply one coat of primer, two

coats of metalshield paint on ornamental metal balustrading, railings or gates (measured both sides).

436619 R STAIRCASE:PREPARE PRIME METALSHIELD METAL STAIRS SM 31.01 Staircase:Wire brush, prepare for and apply one coat of primer, two coats

of metalshield paint on metal staircase, strings, handrail balustrading (measured both sides).

436621 R GUTTER:PREPARE PRIME METALSHIELD EAVES GUTTER LM 3.96 Gutter:Wire brush, prepare and apply coat of primer, two coats of

metalshield paint to outside of eaves gutter including brackets.

436623 R PIPEWORK:PREPARE PRIME METALSHIELD NE300MM LM 3.12 Pipework:Wire brush, prepare for and apply coat of primer, two coats of

metalshield paint to external pipework ne 300mm girth including brackets.

436625 R RAILINGS etc-HAIRPIN:PRIME METALSHIELD SURFACES SM 20.28 Railings, Fencing and Gates – Hairpin:Wire brush, prepare for and apply

one coat of primer, two coats of metalshield paint on hairpin metal balustrading, railings or gates (measured both sides).

436627 R RAILINGS–PLAIN OPEN:PRIME METALSHIELD SURFACES SM 18.97 Railings, Fencing and Gates – Plain Open:Wire brush, prepare for and

apply one coat of primer, two coats of metalshield paint on plain open metal balustrading, railings or gates (measured both sides).

436629 R RAILINGS–CLOSE TYPE:PRIME METALSHIELD SURFACES SM 16.56 Railings, Fencing and Gates – Close Type:Wire brush, prepare for and

apply one coat of primer, two coats of metalshield paint on close type metal balustrading, railings or gates (measured both sides).

Metalshield paint - Existing External Metalwork - Two Coat 436701 R GARAGE DOOR:PREPARE 2 COATS METALSHIELD IT 71.68 Garage Door:Rub down, prepare, spot prime and apply two coats of

metalshield paint on existing painted external surfaces of up and over metal garage door (one side and edges).

436703 R DOOR FRAME:PREPARE 2 COATS METALSHIELD NE 300MM LM 7.09 Door Frame:Rub down, prepare, spot prime and apply two coats of

metalshield paint on existing painted external surfaces of metal frames ne 300mm girth.

Page 182: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

148 Local Space Housing

436705 R DOOR:PREPARE 2 COATS METALSHIELD METAL IT 46.83 Door:Rub down, prepare, spot prime and apply two coats of metalshield

paint on existing painted external surfaces of any size single metal door (both sides and edges).

436707 R DOOR:PREPARE 2 COATS METALSHIELD METAL GLAZED IT 37.98 Door:Rub down, prepare, spot prime and apply two coats of metalshield

paint on existing painted external surfaces of any size single glazed metal door (both sides and edges).

436709 R WINDOW:PREPARE 2 COATS METALSHIELD METAL IT 23.92 Window:Rub down, prepare, spot prime and apply two coats of

metalshield paint on existing painted external surface of metal window ne 1.5sm overall (one side and edges).

436715 R GATES:PREPARE 2 COATS METALSHIELD GATE AND POSTS IT 44.48 Gates:Wire brush, prepare, spot prime and apply two coats of metalshield

paint to both sides of existing painted any size/type single metal gate including all edges and all surfaces of posts.

436717 R RAILINGS-ORNAMENTAL:2 COATS METALSHIELD SURFACES SM 34.74 Balustrading:Wire brush, prepare, spot prime and apply two coats of

metalshield paint on existing painted surfaces of ornamental metal balustrading, railings or gates (measured both sides).

436719 R STAIRCASE:PREPARE 2 COATS METALSHIELD METAL STAIRS SM 37.61 Staircase:Wire brush, prepare, spot prime and apply two coats of

metalshield paint on existing painted surfaces of metal staircase, strings, handrail balustrading (measured both sides).

436721 R GUTTER:PREPARE 2 COATS METALSHIELD EAVES GUTTER LM 4.72 Gutter:Wire brush, prepare, spot prime and apply two coats of metalshield

paint to existing painted surfaces outside of eaves gutter including brackets.

436723 R PIPEWORK:PREPARE 2 COATS METALSHIELD NE300MM LM 4.18 Pipework:Wire brush, prepare, spot prime and apply two coats of

metalshield paint to existing painted surfaces of external pipework ne 300mm girth including brackets.

436725 R RAILINGS-HAIRPIN:2 COATS METALSHIELD SURFACES SM 26.43 Railings, Fencing and Gates – Hairpin:Wire brush, prepare for and apply

one coat of primer, two coats of metalshield paint on hairpin metal balustrading, railings or gates (measured both sides).

436727 R RAILINGS–PLAIN OPEN:2 COATS METALSHIELD SURFACES SM 25.11 Railings, Fencing and Gates – Plain Open:Wire brush, prepare for and

apply one coat of primer, two coats of metalshield paint on plain open metal balustrading, railings or gates (measured both sides).

436729 R RAILINGS–CLOSE TYPE:2 COATS METALSHIELD SURFACES SM 22.93 Railings, Fencing and Gates – Close Type:Wire brush, prepare for and

apply one coat of primer, two coats of metalshield paint on close type metal balustrading, railings or gates (measured both sides).

Page 183: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

149 Local Space Housing

Oil Paint - External Woodwork 438001 R SURFACES:PRIME PAINT GENERAL SURFACES TIMBER SM 24.66 Surfaces:Rub down, prepare and apply one coat of primer, one

undercoat and two coats of gloss paint on general surfaces of woodwork.

438002 R FASCIAS,SOFFITS ETC:PRIME PAINT TIMBER NE 300MM LM 6.66 Fascias, soffits, Bargeboards and the like:Rub down, prepare for, and

apply one coat primer, one undercoat, two coats of gloss paint on surfaces of facias, soffits, bargeboards and the like ne 300mm girth.

438003 R WINDOW:PREPARE PRIME PAINT TIMBER SM 35.86 Window:Rub down, prepare and apply one coat of primer, one

undercoat and two coats of gloss paint on surfaces of wooden windows (one side and edges).

438009 R FRAME:PREPARE PRIME PAINT TIMBER FRAME NE 300MM LM 8.41 Frame:Rub down, prepare and apply one coat of primer, one

undercoat and two coats of gloss paint on timber frame ne 300mm girth.

438011 R DOOR:PREPARE PRIME PAINT TIMBER GLAZED DOOR (OS) IT 28.54 Door:Rub down, prepare for and apply one coat of primer, one

undercoat and two coats of gloss paint to all surfaces of any size or type of single glazed timber door (one sides and edges).

438013 R DOOR:PREPARE PRIME PAINT TIMBER GLAZED DOOR (BS) IT 57.08 Door:Rub down, prepare for and apply one coat of primer, one

undercoat and two coats of gloss paint to all surfaces of any size or type of single glazed timber door (both sides and edges).

438015 R DOOR:PREPARE PRIME PAINT TIMBER DOOR (OS) IT 35.30 Door:Rub down, prepare for and apply one coat of primer, one

undercoat and two coats of gloss paint to all surfaces of any type or size of single timber door (one sides and edges).

438017 R DOOR:PREPARE PRIME PAINT TIMBER DOOR (BS) IT 70.48 Door:Rub down, prepare for and apply one coat of primer, one

undercoat and two coats of gloss paint to all surfaces of any type or size of single timber door (both sides and edges).

438019 R FENCING:PREPARE PRIME PAINT TIMBER FENCE NE 300MM LM 8.75 Fencing:Rub down, prepare for, and apply one coat primer, one

undercoat, two coats of gloss paint on surfaces of fencing and posts ne 300mm girth.

438020 R FENCING ISOLATED:PREPARE PRIME PAINT NE 300MM LM 8.41 Fencing:Rub down, prepare for, and apply one coat primer, one

undercoat, two coats of gloss paint on isolated surfaces of fencing and posts ne 300mm girth.

438053 R FENCING OPEN TYPE:PREPARE PRIME PAINT TIMBER SM 20.72 Fencing:Rub down, prepare for, and apply one coat primer, one

undercoat, two coats of gloss paint on isolated surfaces of open type fencing and posts [measured overall face one side].

Page 184: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

150 Local Space Housing

438055 R FENCING CLOSE TYPE:PREPARE PRIME PAINT TIMBER SM 18.75 Fencing:Rub down, prepare for, and apply one coat primer, one

undercoat, two coats of gloss paint on isolated surfaces of close type fencing and posts [measured overall face one side].

438021 R GATES:PREPARE PRIME PAINT TIMBER GATES POSTS SM 22.37 Gates:Rub down, prepare for, and apply one coat primer, one

undercoat, two coats of gloss paint on surfaces of gates and posts (measured both sides).

Oil Paint - Existing External Woodwork - Two Coat 438162 R FASCIAS,SOFFITS ETC:PAINT 1 GLOSS TIMBER NE 300MM LM 4.87 Fascias, soffits, Bargeboards and the like:Rub down, prepare for, and

apply one undercoat, two coats of gloss paint on existing painted surfaces of facias, soffits, bargeboards and the like ne 300mm girth.

438169 R FENCING ISOLATED:PREPARE 1 GLOSS NE 300MM LM 5.31 Fencing:Rub down, prepare for, and apply one undercoat, one coat of

gloss paint on existing painted surfaces of ranch fencing and posts ne 300mm girth.

438171 R GATES:PREPARE 1 GLOSS TIMBER GATES POSTS SM 11.19 Gates:Rub down, prepare for, and apply one undercoat, one coat of gloss

paint on existing painted surfaces of gates and posts (measured both sides).

438173 R FENCING OPEN TYPE:PREPARE 1 GLOSS TIMBER SM 10.28 Fencing:Rub down, prepare for, and apply one undercoat, one coat of

gloss paint on isolated surfaces of open type fencing and posts [measured overall face one side].

438175 R FENCING CLOSE TYPE:PREPARE 1 GLOSS TIMBER SM 9.19 Fencing:Rub down, prepare for, and apply one undercoat, one coat of

gloss paint on isolated surfaces of close type fencing and posts [measured overall face one side].

Oil Paint - Existing External Woodwork - Three Coat 438112 R FASCIAS,SOFFITS ETC:PAINT 2 GLOSS TIMBER NE 300MM LM 6.41 Fascias, soffits, Bargeboards and the like:Rub down, prepare for, and

apply one undercoat, two coats of gloss paint on existing painted surfaces of facias, soffits, bargeboards and the like ne 300mm girth.

438119 R FENCING ISOLATED:PREPARE 2 GLOSS NE 300MM LM 6.46 Fencing:Rub down, prepare for, and apply one undercoat, two coats of

gloss paint on existing painted surfaces of ranch fencing and posts ne 300mm girth.

438121 R GATES:PREPARE 2 GLOSS TIMBER GATES POSTS SM 16.81 Gates:Rub down, prepare for, and apply one undercoat, two coats of

gloss paint on existing painted surfaces of gates and posts (measured both sides).

438123 R FENCING OPEN TYPE:PREPARE 2 GLOSS TIMBER SM 15.16 Fencing:Rub down, prepare for, and apply one undercoat, two coats of

gloss paint on isolated surfaces of open type fencing and posts [measured overall face one side].

Page 185: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

151 Local Space Housing

438125 R FENCING OPEN TYPE:PREPARE 2 GLOSS TIMBER SM 13.62 Fencing:Rub down, prepare for, and apply one undercoat, two coats of

gloss paint on isolated surfaces of close type fencing and posts [measured overall face one side].

Decorative Wood Protection - External Woodwork 438201 R SURFACES:PREPARE PRIME 3 COATS DECORATIVE STAIN SM 15.45 Surfaces:Rub down, prepare for, and apply touch up primer and

apply three coats of decorative wood stain on external general surfaces of woodwork.

438203 R WINDOW:PREPARE PRIME 3 COATS DECORATIVE STAIN IT 19.91 Window:Rub down, prepare for, and apply touch up primer and

apply three coats of decorative wood stain on surfaces of timber windowl (one side and edges).

438209 R FRAME:PREPARE 3 COATS DECORATIVE FRAME NE 300MM LM 6.76 Frame:Rub down, prepare for, and apply touch up primer and three

coats of decorative wood stain to external surfaces timber sub-frame, ne 300mm girth.

438211 R DOOR:PREPARE 3 COATS DECORATIVE STAIN (O/S) IT 25.02 Door:Rub down, prepare for, and apply touch up primer and apply

three coats decorative wood stain on external surfaces of any sizetype of single door (one side and edges).

438213 R DOOR:PREPARE 3 COATS DECORATIVE STAIN (B/S)) IT 44.17 Door:Rub down, prepare for, and apply touch up primer and apply

three coats decorative wood stain on external surfaces of any size type of single door (both sides and edges)

438215 R DOOR:PREPARE 3 COAT DECORATIVE STAIN GLAZED (O/S) IT 18.39 Door:Rub down, prepare for, and apply touch up primer and apply

three coats of decorative wood stain on any size type single glazed timber door (one side and edges).

438217 R DOOR:PREPARE 3 COAT DECORATIVE STAIN GLAZED (B/S) IT 32.41 Door:Rub down, prepare for, and apply touch up primer and three

coats of decorative wood stain on any size type single glazed timber door (both sides and edges).

438219 R FENCING:PREPARE 3 COATS DECORATIVE STAIN NE 300MM LM 7.63 Fencing:Rub down, prepare for, and apply touch up primer and

three coats of decorative wood stain on surfaces of ranch fencing and posts ne 300mm girth.

438221 R GATES:PREPARE 3 COATS DECORATIVE STAIN GATES POSTS IT 11.89 Gates:Rub down, prepare for, and apply touch up primer and apply

three coats of decorative wood stain to both sides of any size type single timber gate including all edges and on general surfaces of posts.

Cuprinol Trade - External Woodwork 439201 R SURFACES:APPLY 1 COAT CUPRINOL TRADE SM 3.62 Surfaces:Rub down, prepare for and apply one coat of cuprinol trade

cladding and fence opaque finish on external general surfaces of timber cladding etc.

Page 186: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

152 Local Space Housing

439203 R FENCING OPEN TYPE:APPLY 1 COAT CUPRINOL TRADE SM 3.21 Fencing:Rub down, prepare for and apply one coat of cuprinol trade

cladding and fence opaque finish on surfaces of timber open type fencing and posts. [measured overall one side]

439205 R FENCING CLOSE TYPE:APPLY 1 COAT CUPRINOL TRADE SM 3.50 Fencing:Rub down, prepare for and apply one coat of cuprinol trade

cladding and fence opaque finish on surfaces of timber close type fencing and posts. [measured overall one side]

439207 R GATES:APPLY 1 COAT CUPRINOL TRADE SM 3.78 Gates:Rub down, prepare for and apply one coat of cuprinol trade

cladding and fence opaque finish on surfaces of timber gates and posts (measured both sides).

439211 R SURFACES:APPLY 2 COAT CUPRINOL TRADE SM 5.36 Surfaces:Rub down, prepare for and apply two coats of cuprinol trade

cladding and fence opaque finish on external general surfaces of timber cladding etc.

439213 R FENCING OPEN TYPE:APPLY 2 COAT CUPRINOL TRADE SM 4.77 Fencing:Rub down, prepare for and apply two coats of cuprinol trade

cladding and fence opaque finish on surfaces of timber open type fencing and posts. [measured overall one side]

439215 R FENCING CLOSE TYPE:APPLY 2 COAT CUPRINOL TRADE SM 5.13 Fencing:Rub down, prepare for and apply two coats of cuprinol trade

cladding and fence opaque finish on surfaces of timber close type fencing and posts. [measured overall one side]

439217 R GATES: APPLY 2 COAT CUPRINOL TRADE SM 5.64 Gates:Rub down, prepare for and apply two coats of cuprinol trade

cladding and fence opaque finish on surfaces of timber gates and posts (measured both sides).

Internal Decoration Wash Down 441001 X WASH:WASH SURFACES TO ANY ROOM. IT 21.37 Wash:Wash down ceiling, walls, woodwork and metalwork to any

size room.

441003 X WASH:WASH SURFACES OF HALL LANDING STAIR IT 40.48 Wash:Wash down ceiling, walls, woodwork and metalwork to any

size hall, landing and staircase area (classified as a single area).

Strip Polystyrene Ceiling Tiles 441501 X CEILINGS:STRIP POLYSTYRENE TILES SM 17.94 Ceilings:Strip polystyrene ceiling tiles and make good surfaces of

ceiling and walls and remove waste and debris.

Patch Repairs 442001 X WALLS AND CEILINGS:APPLY MIST 2 COATS EMULSION SM 11.20 Walls and Ceilings:Prepare and apply one mist coat and two full

coats of emulsion paint to walls or ceilings in patch repairs to match existing including all joints to adjacent surfaces and finishes.

Page 187: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

153 Local Space Housing

442003 X WALLS AND CEILINGS:APPLY 2 COATS EGGSHELL GLOSS SM 9.18 Walls and Ceilings:Prepare and apply two coats of eggshell or

undercoat and gloss paint to walls or ceilings in patch repairs to match existing including all joints to adjacent surfaces and finishes.

442009 X WALLS AND CEILINGS:HANG LINING,WOODCHIP IN REPAIR SM 16.69 Walls and Ceilings:Prepare, size and hang lining, woodchip or anaglypta

paper, ne one roll, to walls or ceilings in patch repairs to match existing and prepare and apply two coats of emulsion paint to papered surfaces including all joints to adjacent finishes and surfaces.

442011 X WALLS:HANG WALLPAPER IN REPAIR SM 11.92 Walls:Prepare, size and hang approved wallpaper, ne one roll, to walls in

patch repairs to match existing including all joints to adjacent finishes and surfaces.

Paintwork to Ceiling, Walls, Woodwork 450001 X ROOM:REDECORATE UPTO 20SM CEILING AREA IT 162.55 Room:Rub down, prepare for and apply two coats of emulsion to

ceilings and walls, one undercoat and gloss on all previously painted surfaces of room upto 20.00sm ceiling area.

450019 X ROOM:REDECORATE 20-25SM CEILING AREA IT 203.18 Room:Rub down, prepare for and apply two coats of emulsion to ceilings

and walls, one undercoat and gloss on all previously painted surfaces of room over 20.00 and ne 25.00sm ceiling area.

450023 X ROOM:REDECORATE 25-30SM CEILING AREA IT 243.82 Room:Rub down, prepare for and apply two coats of emulsion to ceilings

and walls, one undercoat and gloss on all previously painted surfaces of room over 15.00 and ne 20.00sm ceiling area.

450027 X ROOM:REDECORATE OVER 30SM CEILING AREA IT 284.46 Room:Rub down, prepare for and apply two coats of emulsion to ceilings

and walls, one undercoat and gloss on all previously painted surfaces of room over 30.00sm ceiling area.

450009 X HALLSTAIRS:REDECORATE 2 STOREY IT 493.90 HallStairs:Rub down, prepare for and apply two coats of emulsion

to ceilings and walls, one undercoat and gloss on all previously painted surfaces of hall, landing and staircase area complete. (2 storey) (classified as a single area).

450010 X HALLSTAIRS:REDECORATE 3 STOREY IT 740.85 HallStairs:Rub down, prepare for and apply two coats of emulsion

to ceilings and walls, one undercoat and gloss on all previously painted surfaces of hall, landing and staircase area complete (3 storey) (classified as a single area).

450011 X HALL:REDECORATE COMPLETE OVER 3SM CEILING AREA IT 276.34 Hall:Rub down, prepare for and apply two coats of emulsion to

ceilings and walls, one undercoat and gloss on all previously painted surfaces of lobby, hall or corridor over 3.00sm ceiling area complete. (classified as a single area)

Page 188: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

154 Local Space Housing

450017 X LOBBY:REDECORATE COMPLETE NE 3SM CEILING AREA IT 140.44 Lobby:Rub down, prepare for and apply two coats of emulsion to

ceilings and walls, one undercoat and gloss on all previously painted surfaces of lobby or hall ne 3.00sm ceiling area complete. (classified as a single area)

450031 X CORRIDOR/COMMUNAL AREA:REDECORATE SM 17.73 Corridor/Communal Room:Rub down, prepare for and apply two coats of

emulsion to ceilings and walls, one undercoat and gloss on all previously painted surfaces of corridors, open communal areas etc [measured per square metre of ceiling area.]

Paintwork to Ceiling, Walls, Washdown Woodwork 450507 X ROOM:WASH REDECORATE UPTO 20SM CEILING AREA IT 104.78 Room:Rub down, prepare for and apply two coats of emulsion to

ceilings and walls, wash down only to all other previously painted surfaces of room upto 20.00sm ceiling area.

450519 X ROOM:WASH REDECORATE 20-25SM CEILING AREA IT 128.48 Room:Rub down, prepare for and apply two coats of emulsion to ceilings

and walls, wash down only to all other previously painted surfaces of room over 20.00 and ne 25.00sm ceiling area.

450523 X ROOM:WASH REDECORATE 25-30SM CEILING AREA IT 153.17 Room:Rub down, prepare for and apply two coats of emulsion to ceilings

and walls, wash down only to all other previously painted surfaces of room over 25.00 and ne 30.00sm ceiling area.

450527 X ROOM:WASH REDECORATE OVER 30SM CEILING AREA IT 177.87 Room:Rub down, prepare for and apply two coats of emulsion to ceilings

and walls, wash down only to all other previously painted surfaces of room over 30.00sm ceiling area.

450509 X HALLSTAIRS:WASH REDECORATE 2 STOREY IT 287.59 HallStairs:Rub down, prepare for and apply two coats of emulsion

to ceilings and walls, washdown only to all other previously painted surfaces of hall, landing and staircase area complete (2 storey) (classified as a single area).

450510 X HALLSTAIRS:WASH REDECORATE 3 STOREY IT 431.38 HallStairs:Rub down, prepare for and apply two coats of emulsion

to ceilings and walls, wash down only to all other previously painted surfaces of hall, landing and staircase area complete (3 storey) (classified as a single area).

450511 X HALL:WASH REDECORATE OVER 3SM CEILING AREA IT 183.18 Hall:Rub down, prepare for and apply two coats of emulsion to

ceilings and walls, wash down only to all other previously painted surfaces of lobby, hall or corridor over 3.00sm ceiling area complete (classified as a single area).

450517 X LOBBY:WASH REDECORATE NE 3SM CEILING AREA IT 72.52 Lobby:Rub down, prepare for and apply two coats of emulsion to

ceilings and walls, wash down only to all other previously painted surfaces of lobby or hall ne 3.00sm ceiling area complete (classified as a single area).

Page 189: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

155 Local Space Housing

450529 X CORRIDOR/COMMUNAL AREA:WASH REDECORATE SM 12.35 Corridor/Communal Room:Rub down, prepare for and apply two coats of

emulsion to ceilings and walls, wash down only to all other previously painted surfaces of corridors, open communal areas etc [measured per square metre of ceiling area.].

Paintwork to Ceilings Only 450607 X ROOM:REDECORATE CEILING UPTO 20SM CEILING AREA IT 55.77 Room:Rub down, prepare for and apply two coats of emulsion to

ceilings only of room upto 20.00sm ceiling area.

450615 X ROOM:REDECORATE CEILING 20-25SM AREA IT 69.71 Room:Rub down, prepare for and apply two coats of emulsion to ceilings

only of room over 20.00 and ne 25.00sm ceiling area.

450617 X ROOM:REDECORATE CEILING 25-30SM AREA IT 85.65 Room:Rub down, prepare for and apply two coats of emulsion to ceilings

only of room over 25.00 and ne 30.00sm ceiling area.

450619 X ROOM:REDECORATE CEILING OVER 30SM AREA IT 100.59 Room:Rub down, prepare for and apply two coats of emulsion to ceilings

only of room over 30.00sm ceiling area.

450609 X HALLSTAIRS:REDECORATE CEILINGS 2 STOREY IT 125.66 HallStairs:Rub down, prepare for and apply two coats of emulsion

to ceilings of hall, landing and staircase area complete (2 storey) (classified as a single area).

450610 X HALLSTAIRS:REDECORATE CEILINGS 3 STOREY IT 181.43 HallStairs:Rub down, prepare for and apply two coats of emulsion

to ceilings of hall, landing and staircase area complete (3 storey) (classified as a single area).

450611 X HALL:REDECORATE CEILINGS OVER 3SM AREA IT 55.77 Hall:Rub down, prepare for and apply two coats of emulsion to

ceilings of lobby, hall or corridor over 3.00sm area complete (classified as a single area).

450612 X LOBBY:REDECORATE CEILINGS NE 3SM AREA IT 23.09 Lobby:Rub down, prepare for and apply two coats of emulsion to

ceilings of lobby or hall ne 3.00sm area complete (classified as a single area).

450621 X CORRIDOR/COMMUNAL ROOMS:REDECORATE CEILING SM 4.16 Corridor/Communal Room:Rub down, prepare for and apply two coats of

emulsion to ceilings only of corridor or open communal areas. [measured per square metre of ceiling area.]

Strip Paper 451007 X ROOM:STRIP PAPER UPTO 20SM CEILING AREA IT 209.02 Room:Extra for stripping any number of layers of any type of

wallpaper or wallcovering from walls and ceilings including any extra preparation to receive new decoration for room upto 20.00sm ceiling area.

Page 190: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

156 Local Space Housing

451015 X ROOM:STRIP PAPER OVER 20SM CEILING AREA SM 11.60 Room:Extra for stripping any number of layers of any type of wallpaper or

wallcovering from walls and ceilings including any extra preparation to receive new decoration for room over 20.00 ceiling area. [measured per square metre of ceiling area in excess of 20.00sm.]

451009 X HALLSTAIRS:STRIP PAPER 2 STOREY IT 247.54 HallStairs:Extra for stripping any number of layers of any type of

wallpaper or wallcovering from walls and ceilings to any hall, landing and stair, including any extra preparation to receive new decoration (2 storey) (classified as a single area).

451010 X HALLSTAIRS:STRIP PAPER 3 STOREY IT 358.69 HallStairs:Extra for stripping any number of layers of any type of

wallpaper or wallcovering from walls and ceilings to any hall, landing and stair including any extra preparation to receive new decoration (3 storey) (classified as a single area).

451011 X HALL:STRIP PAPER OVER 3SM CEILING AREA IT 171.04 Hall:Extra for stripping any number of layers of any type of

wallpaper or coverings from walls and ceilings to any lobby, hall, or corridor over 3.00sm ceiling area including any extra preparation to receive new decoration (classified as a single area).

451012 X LOBBY:STRIP PAPER NE 3SM CEILING AREA IT 53.24 Lobby:Extra for stripping any number of layers of any type of

wallpaper or coverings from walls and ceilings to any lobby or hall ne 3.00sm ceiling area including any extra preparation to receive new decoration (classified as a single area).

451017 X CORRIDOR/COMMUNAL ROOMS:STRIP PAPER SM 10.72 Corridor/Communal Room :Extra for stripping any number of layers of any

type of wallpaper or wallcovering from walls and ceilings of corridor or open communal areas including any extra preparation to receive new decoration. [measured per square metre of ceiling area]

Strip Painted Paper 451107 X ROOM:STRIP PAPER UPTO 20SM CEILING AREA IT 501.82 Room:Extra for stripping any number of layers of any type of

painted wallpaper or wallcovering from walls and ceilings including any extra preparation to receive new decoration for room upto 20.00sm ceiling area (only to be charged when specifically instructed by Client Representative).

451115 X ROOM:STRIP PAINTED PAPER OVER 20SM AREA SM 28.23 Room:Extra for stripping any number of layers of any type of painted

wallpaper or wallcovering from walls and ceilings including any extra preparation to receive new decoration for room over 20.00 ceiling area. [measured per square metre of ceiling area in excess of 20.00sm.] (only to be charged when specifically instructed by Client Representative).

451109 X HALLSTAIRS:STRIP PAINTED PAPER 2 STOREY IT 596.36 HallStairs:Extra for stripping any number of layers of any type of

painted wallpaper or wallcovering from walls and ceilings to any hall, landing and stair, including any extra preparation to receive new decoration (classified as a single area) (2 storey) (only to be charged when specifically instructed by Client Representative).

Page 191: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

157 Local Space Housing

451110 X HALLSTAIRS:STRIP PAINTED PAPER 3 STOREY IT 864.63 HallStairs:Extra for stripping any number of layers of any type of

painted wallpaper or wallcovering from walls and ceilings to any hall, landing and stair, including any extra preparation to receive new decoration (classified as a single area) (3 storey) (only to be charged when specifically instructed by Client Representative).

451111 X HALL:STRIP PAINTED PAPER OVER 3SM CEILING AREA IT 416.13 Hall:Extra for stripping any number of layers of any type of painted

wallpaper or coverings from walls and ceilings to any lobby, hall, or corridor over 3.00sm ceiling area including any extra preparation to receive new decoration (classified as a single area) (only to be charged when specifically instructed by Client Representative).

451112 X LOBBY:STRIP PAINTED PAPER NE 3SM CEILING AREA IT 204.60 Lobby:Extra for stripping any number of layers of any type of

painted wallpaper or coverings from walls and ceilings to any lobby or hall ne 3.00sm total ceiling area including any extra preparation to receive new decoration (classified as a single area) (only to be charged when specifically instructed by Client Representative).

451117 X CORRIDOR/COMMUNAL ROOMS:STRIP PAINTED PAPER SM 25.82 Corridor/Communal Room:Extra for stripping any number of layers of any

type of painted wallpaper or wallcovering from walls and ceilings of corridor or open communal areas including any extra preparation to receive new decoration. [measured per square metre of ceiling area] (only to be charged when specifically instructed by Client Representative).

Ceiling Finishes - Alternatives 452007 X ROOM:PAPER CEILING UPTO 20SM CEILING AREA IT 141.52 Room:Extra for prepare, size and hang lining, woodchip or

anaglypta paper to ceilings upto 20.00sm ceiling area.

452041 X ROOM:PAPER CEILING OVER 20SM CEILING AREA SM 7.66 Room:Extra for prepare, size and hang lining, woodchip or anaglypta

paper to ceilings over 20.00sm ceiling area. [measured per square metre of ceiling area in excess of 20.00sm.]

452009 X HALLSTAIRS:PAPER CEILING 2 STOREY IT 169.72 HallStairs:Extra for prepare, size and hang lining, woodchip or

anaglypta paper to ceilings to any hall, landing and staircase area (2 storey) (classified as a single area).

452010 X HALLSTAIRS:PAPER CEILING 3 STOREY IT 258.30 HallStairs:Extra for prepare, size and hang lining, woodchip or

anaglypta paper to ceilings to any hall, landing and staircase area (3 storey) (classified as a single area).

452008 X HALL:PAPER CEILINGS OVER 3SM CEILING AREA IT 82.22 Hall:Extra for prepare, size and hang lining, woodchip or anaglypta

paper to ceilings to any lobby, hall or corridor over 3.00sm ceiling area (classified as a single area).

452033 X LOBBY:PAPER CEILINGS NE 3SM CEILING AREA IT 27.36 Lobby:Extra for prepare, size and hang lining, woodchip or

anaglypta paper to ceilings to any lobby or hall ne 3.00sm ceiling area (classified as a single area).

Page 192: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

158 Local Space Housing

452043 X CORRIDOR/COMMUNAL ROOMS:PAPER CEILING SM 7.00 Corridor/Communal Room:Extra for prepare, size and hang lining,

woodchip or anaglypta paper to ceilings of corridor or open communal areas [measured per square metre of ceiling area]

452017 X ROOM:ARTEX CEILING UPTO 20SM CEILING AREA IT 85.21 Room:Extra for prepare and apply Artex or similar to ceilings upto

20.00sm ceiling area.

452045 X ROOM:ARTEX CEILING OVER 30SM CEILING AREA SM 4.38 Room:Extra for prepare and apply Artex or similar to ceilings over

20.00sm ceiling area. [measured per square metre of ceiling area in excess of 20.00sm.]

452019 X HALLSTAIRS:ARTEX CEILINGS 2 STOREY IT 75.45 HallStairs:Extra for prepare and apply Artex or similar to ceilings of

any hall, landing and staircase area (2 storey) (classified as a single area).

452020 X HALLSTAIRS:ARTEX CEILINGS 3 STOREY IT 112.74 HallStairs:Extra for prepare and apply Artex or similar to ceilings of

any hall, landing and staircase area (3 storey) (classified as a single area).

452018 X HALL:ARTEX CEILINGS OVER 3SM CEILING AREA IT 74.04 Hall:Extra for prepare and apply Artex or similar to ceilings of any

lobby, hall or corridor over 3.00sm ceiling area (classified as a single area).

452047 X CORRIDOR/COMMUNAL ROOMS:ARTEX CEILING SM 4.16 Corridor/Communal Room:Extra for prepare and apply Artex or similar to

ceilings to ceilings of corridor or open communal areas [measured per square metre of ceiling area].

452027 X ROOM:EGGSHELL GLOSS CEILING UPTO 20SM CEILING AREA IT 46.96 Room:Extra for prepare and apply two coats of eggshell or

undercoat and gloss to ceilings, upto 20.00sm ceiling area.

452049 X ROOM:EGGSHELL GLOSS CEILING OVER 20SM CEILING AREA SM 3.06 Room:Extra for prepare and apply two coats of eggshell or undercoat and

gloss to ceilings, over 20.00sm ceiling area. [measured per square metre of ceiling area in excess of 20.00sm.]

452029 X HALLSTAIRS:EGGSHELL OR GLOSS CEILING 2 STOREY IT 45.68 HallStairs:Extra for prepare and apply two coats of eggshell or

undercoat and gloss to ceilings of any hall, landing and staircase area. (2 storey) (classified as a single area).

452030 X HALLSTAIRS:EGGSHELL OR GLOSS CEILING 3 STOREY IT 69.26 HallStairs:Extra for prepare and apply two coats of eggshell or

undercoat and gloss to ceilings of any hall, landing and staircase area (3 storey) (classified as a single area).

452031 X HALL:EGGSHELL GLOSS CEILING OVER 3SM CEILING AREA IT 57.83 Hall:Extra for prepare and apply two coats of eggshell or undercoat

and gloss to ceilings of any lobby, hall or corridor over 3.00sm ceiling area (classified as a single area).

Page 193: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

159 Local Space Housing

452037 X LOBBY:EGGSHELL GLOSS CEILING NE 3SM CEILING AREA IT 18.41 Lobby:Extra for prepare and apply two coats of eggshell or

undercoat and gloss to ceilings of any lobby or hall ne 3.00sm ceiling area (classified as a single area).

452051 X CORRIDOR/OMMUNAL ROOMS:EGGSHELL GLOSS CEILING SM 2.93 Corridor/Communal Room:Extra for prepare and apply two coats of

eggshell or undercoat and gloss to ceilings to ceilings of corridor or open communal areas [measured per square metre of ceiling area]

Wall Finishes - Alternatives 453007 X ROOM:LINING PAPER WALLS UPTO 20SM CEILING AREA IT 120.55 Room:Extra for prepare, size and hang lining, woodchip or

anaglypta paper to walls of room upto 20.00sm ceiling area.

453037 X ROOM:LINING PAPER WALLS OVER 20SM CEILING AREA SM 7.63 Room:Extra for prepare, size and hang lining, woodchip or anaglypta

paper to walls of room over 20.00sm ceiling area. [measured per square metre of ceiling area in excess of 20.00sm.]

453009 X HALLSTAIRS:LINING PAPER WALLS 2 STOREY IT 231.46 HallStairs:Extra for prepare, size and hang lining, woodchip or

anaglypta paper to walls of any size hall, landing and staircase area (2 storey) (classified as a single area).

453008 X HALLSTAIRS:LINING PAPER WALLS 3 STOREY IT 347.40 HallStairs:Extra for prepare, size and hang lining, woodchip or

anaglypta paper to walls of any size hall, landing and staircase area (3 storey) (classified as a single area).

453010 X HALL:LINING PAPER WALLS OVER 3SM CEILING AREA IT 143.96 Hall:Extra for prepare, size and hang lining, woodchip or anaglypta

paper to walls of any lobby, hall or corridor over 3.00sm ceiling area (classified as a single area).

453032 X LOBBY:LINING PAPER WALLS NE 3SM CEILING AREA IT 52.03 Lobby:Extra for prepare, size and hang lining, woodchip or

anaglypta paper to walls of any lobby or hall ne 3.00sm ceiling area (classified as a single area).

453039 X CORRIDOR/COMMUNAL ROOMS:LINING PAPER WALLS SM 12.00

Corridor/Communal Room:Extra for prepare, size and hang lining, woodchip or anaglypta paper to walls of corridor or open communal areas [measured per square metre of ceiling area]

453017 X ROOM:WALLPAPER WALLS UPTO 20SM CEILING AREA IT 132.80 Room:Extra for prepare, size and hang wallpaper in lieu of two

coats of emulsion to walls of room upto 20.00sm ceiling area.

453041 X ROOM:WALLPAPER WALLS OVER 20SM CEILING AREA SM 10.13 Room:Extra for prepare, size and hang wallpaper in lieu of two coats of

emulsion to walls of room over 20.00sm ceiling area. [measured per square metre of ceiling area in excess of 20.00sm.]

453019 X HALLSTAIRS:WALLPAPER WALLS 2 STOREY IT 237.10 HallStairs:Extra for prepare, size and hang wallpaper in lieu of two

coats of emulsion to walls of any size hall, landing and staircase area (2 storey) (classified as a single area).

Page 194: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

160 Local Space Housing

453018 X HALLSTAIRS:WALLPAPER WALLS 3 STOREY IT 355.85 HallStairs:Extra for prepare, size and hang wallpaper in lieu of two

coats of emulsion to walls of any size hall, landing and staircase area (3 storey) (classified as a single area).

453020 X HALL:WALLPAPER WALLS OVER 3SM CEILING AREA IT 146.78 Hall:Extra for prepare, size and hang wallpaper in lieu of two coats

of emulsion to walls of any lobby, hall or corridor over 3.00sm ceiling area (classified as a single area).

453033 X LOBBY:WALLPAPER WALLS NE 3SM CEILING AREA IT 61.98 Lobby:Extra for prepare, size and hang wallpaper in lieu of two

coats of emulsion to walls of any lobby or hall ne 3.00sm ceiling area (classified as a single area).

453043 X CORRIDOR/COMMUNAL ROOMS:WALLPAPER WALLS SM 14.50 Corridor/Communal Room:Extra for prepare, size and hang wallpaper in

lieu of two coats of emulsion to walls of corridor or open communal areas [measured per square metre of ceiling area]

453027 X ROOM:EGGSHELL GLOSS WALLS UPTO 20SM CEILING AREA IT 76.32 Room:Extra for prepare and apply two coats eggshell or undercoat

and gloss to walls of room upto 20.00sm ceiling area.

453045 X ROOM:EGGSHELL GLOSS WALLS OVER 20SM CEILING AREA SM 10.38 Room:Extra for prepare and apply two coats eggshell or undercoat and

gloss to walls of room over 20.00sm ceiling area. [measured per square metre of ceiling area in excess of 20.00sm.]

453029 X HALLSTAIRS:EGGSHELL OR GLOSS WALLS 2 STOREY IT 149.65 HallStairs:Extra for prepare and apply two coats eggshell or

undercoat and gloss to walls of any size hall, landing and staircase area (2 storey) (classified as a single area).

453030 X HALLSTAIRS:EGGSHELL OR GLOSS WALLS 3 STOREY IT 227.47 HallStairs:Extra for prepare and apply two coats of eggshell or

undercoat and gloss to walls of any hall, landing and staircase area (3 storey) (classified as a single area).

453031 X HALL:EGGSHELL OR GLOSS WALLS OVER 3SM CEILING AREA IT 85.20 Hall:Extra for prepare and apply two coats eggshell or undercoat

and gloss to walls of any lobby, hall or corridor over 3.00sm ceiling area (classified as a single area).

453034 X LOBBY:EGGSHELL OR GLOSS WALLS NE 3SM CEILING AREA IT 80.33 Lobby:Extra for prepare and apply two coats eggshell or undercoat

and gloss to walls of any lobby or hall ne 3.00sm ceiling area (classified as a single area).

453047 X CORRIDOR/COMMUNAL ROOMS:EGGSHELL WALLS SM 9.95 Corridor/Communal Room:Extra for prepare and apply two coats eggshell

or undercoat and gloss to walls of corridor or open communal areas [measured per square metre of ceiling area]

Page 195: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

161 Local Space Housing

Internal Paintwork - Complete Dwellings 470001 X DWELLING:REDECORATE 1 BEDROOM FLAT IT 659.55 Dwelling:Redecorate complete one bedroom Flat or Bungalow, rub

down, prepare for and apply two coats of emulsion to ceilings and walls, one undercoat and gloss on all other previously painted surfaces.

470002 X DWELLING:REDECORATE 2 BEDROOM FLAT IT 787.08 Dwelling:Redecorate complete two bedroom Flat or Bungalow, rub

down, prepare for and apply two coats of emulsion to ceilings and walls, one undercoat and gloss on all other previously painted surfaces.

470003 X DWELLING:REDECORATE 3 BEDROOM FLAT IT 914.62 Dwelling:Redecorate complete three bedroom Flat or Bungalow, rub

down, prepare for and apply two coats of emulsion to ceilings and walls, one undercoat and gloss on all other previously painted surfaces.

470010 X DWELLING:REDECORATE 2 BEDROOM HOUSE IT 1013.40 Dwelling:Redecorate complete two bedroom House or Maisonette,

rub down, prepare for and apply two coats of emulsion to ceilings and walls, one undercoat and gloss on all other previously painted surfaces.

470011 X DWELLING:REDECORATE 3 BEDROOM HOUSE IT 1140.93 Dwelling:Redecorate complete three bedroom House or Maisonette,

rub down, prepare for and apply two coats of emulsion to ceilings and walls, one undercoat and gloss on all other previously painted surfaces.

470012 X DWELLING:REDECORATE 4 BEDROOM HOUSE IT 1268.46 Dwelling:Redecorate complete four bedroom House or Maisonette,

rub down, prepare for and apply two coats of emulsion to ceilings and walls, one undercoat and gloss on all other previously painted surfaces.

470040 X DWELLING:REDECORATE BEDSIT NE 20SM CEILING AREA IT 448.86 Dwelling:Redecorate complete bedsit ne 20.00sm ceiling area

including all rooms, rub down, prepare for and apply two coats of emulsion to ceilings and walls, one undercoat and gloss on all other previously painted surfaces.

470041 X DWELLING:REDECORATE BEDSIT 20 TO 30SM CEILING AREA IT 508.25 Dwelling:Redecorate complete bedsit 20.00 - 30.00sm ceiling area

including all rooms, rub down, prepare for and apply two coats of emulsion to ceilings and walls, one undercoat and gloss on all other previously painted surfaces.

470042 X DWELLING:REDECORATE BEDSIT OVER 30SM CEILING AREA IT 633.29 Dwelling:Redecorate complete bedsit exceeding 30.00sm ceiling

area including all rooms, rub down, prepare for and apply two coats of emulsion to ceilings and walls, one undercoat and gloss on all other previously painted surfaces.

Page 196: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

162 Local Space Housing

470045 X DWELLING:REDECORATE MULTIPLE OCCUPIED 3 BED FLAT IT 858.03 Dwelling:Redecorate all rooms in three bedroom multiple occupancy

flat complete comprising bedrooms, lobby, hall, communal kitchen, bathroom, toilet and shower room including rub down, prepare for and apply two coats of emulsion to ceilings and walls, one undercoat and gloss on all other previously painted surfaces.

470046 X DWELLING:REDECORATE MULTIPLE OCCUPIED 4 BED FLAT IT 1012.76 Dwelling:Redecorate all rooms in four bedroom multiple occupancy

flat complete comprising bedrooms, lobby, hall, communal kitchen, bathroom, toilet and shower room including rub down, prepare for and apply two coats of emulsion to ceilings and walls, one undercoat and gloss on all other previously painted surfaces.

470047 X DWELLING:REDECORATE MULTIPLE OCCUPIED 5 BED FLAT IT 1167.50 Dwelling:Redecorate all rooms in five bedroom multiple occupancy

flat complete comprising bedrooms, lobby, hall, communal kitchen, bathroom, toilet and shower room including rub down, prepare for and apply two coats of emulsion to ceilings and walls, one undercoat and gloss on all other previously painted surfaces.

Internal Paintwork and Washdown - Complete Dwellings 470501 X DWELLING:WASH 2CT REDECORATION 1 BEDROOM FLAT IT 429.43 Dwelling:Redecoration and washdown complete one bedroom Flat

or Bungalow, rub down, prepare for and apply two coats of emulsion to ceilings and walls, wash down only to all other previously painted surfaces.

470502 X DWELLING:WASH 2CT REDECORATION 2 BEDROOM FLAT IT 512.32 Dwelling:Redecoration and washdown complete two bedroom Flat

or Bungalow, rub down, prepare for and apply two coats of emulsion to ceilings and walls, wash down only to all other previously painted surfaces

470503 X DWELLING:WASH 2CT REDECORATION 3 BEDROOM FLAT IT 595.22 Dwelling:Redecoration and washdown complete three bedroom Flat

or Bungalow, rub down, prepare for and apply two coats of emulsion to ceilings and walls, wash down only to all other previously painted surfaces.

470510 X DWELLING:WASH 2CT REDECORATION 2 BEDROOM HOUSE IT 649.55 Dwelling:Redecoration and washdown complete two bedroom

House or Maisonette, rub down, prepare for and apply two coats of emulsion to ceilings and walls, wash down only to all other previously painted surfaces.

470511 X DWELLING:WASH 2CT REDECORATION 3 BEDROOM HOUSE IT 732.45 Dwelling:Redecoration and washdown complete three bedroom

House or Maisonette, rub down, prepare for and apply two coats of emulsion to ceilings and walls, wash down only to all other previously painted surfaces.

470512 X DWELLING:WASH 2CT REDECORATION 4 BEDROOM HOUSE IT 813.16 Dwelling:Redecoration and washdown complete four bedroom

House or Maisonette, rub down, prepare for and apply two coats of emulsion to ceilings and walls, wash down only to all other previously painted surfaces.

Page 197: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

163 Local Space Housing

470520 X DWELLING:WASH 1CT REDECORATION 1 BEDROOM FLAT IT 244.26 Dwelling:Redecoration and washdown complete one bedroom Flat

or Bungalow, rub down, prepare for and apply one coat of emulsion to ceilings and walls, wash down only to all other previously painted surfaces.

470521 X DWELLING:WASH 1CT REDECORATION 2 BEDROOM FLAT IT 292.27 Dwelling:Redecoration and washdown complete two bedroom Flat

or Bungalow, rub down, prepare for and apply one coat of emulsion to ceilings and walls, wash down only to all other previously painted surfaces.

470522 X DWELLING:WASH 1CT REDECORATION 3 BEDROOM FLAT IT 338.09 Dwelling:Redecoration and washdown complete three bedroom Flat

or Bungalow, rub down, prepare for and apply one coat of emulsion to ceilings and walls, washdown only to all other previously painted surfaces.

470530 X DWELLING:WASH 1CT REDECORATION 2 BEDROOM HOUSE IT 370.73 Dwelling:Redecoration and washdown complete two bedroom

House or Maisonette, rub down, prepare for and apply one coat of emulsion to ceilings and walls, wash down only to all other previously painted surfaces.

470531 X DWELLING:WASH 1CT REDECORATION 3 BEDROOM HOUSE IT 418.74 Dwelling:Redecoration and washdown complete three bedroom

House or Maisonette, rub down, prepare for and apply one coat of emulsion to ceilings and walls, wash down only to all other previously painted surfaces.

470532 X DWELLING:WASH 1CT REDECORATION 4 BEDROOM HOUSE IT 464.57 Dwelling:Redecoration and washdown complete four bedroom

House or Maisonette, rub down, prepare for and apply one coat of emulsion to ceilings and walls, wash down only to all other previously painted surfaces.

470540 X DWELLING:WASH 2CT REDEC BEDSIT NE 20SM CLG AREA IT 279.88 Dwelling:Redecoration and washdown complete bedsit ne 20.00sm

ceiling area including all rooms, rub down, prepare for and apply two coats of emulsion to ceilings and walls, wash down only to all other previously painted surfaces.

470541 X DWELLING:WASH 2CT REDEC BEDSIT 20 TO 30SM CLG AREA IT 333.27 Dwelling:Redecoration and washdown complete bedsit 20.00 to

30.00sm ceiling area including all rooms, rub down, prepare for and apply two coats of emulsion to ceilings and walls, wash down only to all other previously painted surfaces.

470542 X DWELLING:WASH 2CT REDEC BEDSIT OVER 30SM CLG AREA IT 394.41 Dwelling:Redecoration and washdown complete bedsit exceeding

30.00sm ceiling area including all rooms, rub down, prepare for and apply two coats of emulsion to ceilings and walls, wash down only to all other previously painted surfaces.

470545 X DWELLING:WASH 2CT REDEC MULTIPLE OCC 3 BED FLAT IT 535.82 Dwelling:Redecoration and washdown all rooms in three bedroom

multiple occupancy flat complete comprising bedrooms, lobby, hall, communal kitchen, bathroom, toilet and shower room including rub down, prepare for and apply two coats of emulsion to ceilings and walls, wash down only to all other previously painted surfaces.

Page 198: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

164 Local Space Housing

470546 X DWELLING:WASH 2CT REDEC MULTIPLE OCC 4 BED FLAT IT 630.22 Dwelling:Redecoration and washdown all rooms in four bedroom

multiple occupancy flat complete comprising bedrooms, lobby, hall, communal kitchen, bathroom, toilet and shower room including rub down, prepare for and apply two coats of emulsion to ceilings and walls, wash down only to all other previously painted surfaces.

470547 X DWELLING:WASH 2CT REDEC MULTIPLE OCC 5 BED FLAT IT 724.62 Dwelling:Redecoration and washdown all rooms in five bedroom

multiple occupancy flat complete comprising bedrooms, lobby, hall, communal kitchen, bathroom, toilet and shower room including rub down, prepare for and apply two coats of emulsion to ceilings and walls, wash down only to all other previously painted surfaces.

Work to Room Heights above 3.00m 470088 X ROOM:WHOLE REDECORATION ADDITION HT ABOVE 3.0M SM 7.57 Room:Additional allowance for working in room with ceiling 3.00m

above floor level and painting all walls, ceilings and woodwork (measured floor area).

Page 199: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

165 Local Space Housing

CLEANING AND CLEARANCE Internal Cleaning and Clearance 460012 X DWELLING:CLEAN TO LETTABLE STANDARD IT 77.65 Dwelling:Clean, wash down, scrub all floors, window boards, skirtings

etc, clean all kitchen units, sanitary fittings and other landlords fittings, clean all windows internally, disinfect toilets, spray airfreshener all to Client’s void lettable standard.

460003 X DWELLING:CLEAR OUT COMPLETE IT 65.22 Dwelling:Clear out, remove all rubbish, furniture, carpets and all non-

approved fittings to tip and make ready for incoming tenants. (Provision of skip or equivalent deemed necessary by Client Representative to be charged separately as Item 460033 or 460035).

460004 X ROOFSPACE:CLEAR OUT COMPLETE IT 69.52 Roofspace:Clear out, remove all rubbish, debris, previous tenants stored

items and all non-approved fittings to tip and make ready for incoming tenants. (Provision of skip or equivalent deemed necessary by Client Representative to be charged separately as Item 460033 or 460035).

460009 X DWELLING:CLEAR EXCEPTIONALLY DIRTY IT 203.57 Dwelling:Clear out ‘exceptionally’ dirty dwelling, remove all rubbish,

furniture, carpets and non-approved fittings to approved tip, initial wash and scrub with disinfectant floors, woodwork, walls and ceilings and all other surfaces, including drying out with de-humidifier. (Provision of skip or equivalent deemed necessary by Client Representative to be charged separately as Item 460033 or 460035).

460010 X DWELLING:CLEAR ENVIRONMENTALLY DIRTY IT 443.11 Dwelling:Clear out socially and environmentally dirty dwelling, remove all

rubbish, furniture, carpets and non-approved fittings to approved tip, carefully clean out and dispose of anti-social, medical or human debris, initial wash and scrub with disinfectant floors, woodwork, walls and ceilings and all other surfaces and dry by de-humidifier. (Provision of skip or equivalent deemed necessary by Client Representative to be charged separately as Item 460033 or 460035).

460006 X BASEMENT:CLEAR OUT COMPLETE IT 62.95 Basement:Clear out, remove all rubbish, debris, previous tenants stored

items and all non-approved fittings to tip and make ready for incoming tenants. (Provision of skip or equivalent deemed necessary by Client Representative to be charged separately as Item 460033 or 460035).

External Clearance 460025 X GARDEN:CLEAR DEBRIS IT 37.45 Garden:Clear away all litter and rubbish including scrap metal, timber,

broken glass, garden debris, fallen leaves, dumped materials and stones, load up and remove from site to an approved tip.

460026 X GARDEN:CLEAR EXCEPTIONAL DEBRIS IT 112.34 Garden:Clear up exceptionally littered and over- grown garden, clear away

all litter and rubbish including scrap metal, timber, broken glass, garden debris, fallen leaves, fly tipped materials, building debris, load up and remove from site to an approved tip.

Page 200: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

166 Local Space Housing

460027 X GARDEN:CUT GRASS NE 100MM HIGH SM 1.75 Garden:Litter pick including removal of minor objects and cut grass (ne

100mm high) with rotary or cylinder mower including bag up cut grass and remove.

460028 X GARDEN:CUT GRASS OVER 100MM HIGH SM 2.19 Garden:Litter pick including removal of minor objects and cut grass (over

100mm high) with rotary or cylinder mower including bag up cut grass and remove.

460029 X GARAGE:CLEAR DEBRIS IT 50.74 Garage:Clear out, and remove all contents to an approved tip or recycling

centre and make ready for new tenant.

460031 X SHED:CLEAR DEBRIS IT 35.18 Shed:Clear out, and remove all contents to an approved tip or recycling

and make ready for new tenant.

Disposal of Previous Tenants Rubbish 460033 X DWELLING:PROVIDE MINI SKIP FOR RUBBISH NO 120.75 Dwelling:Provide mini skip or equivalent for removal of excessive domestic

rubbish etc., to approved tip or recycling centre, including costs of landfill tax, (only to be charged when specifically instructed by Client Representative).

460035 X DWELLING OR GARDEN:PROVIDE SKIP FOR RUBBISH NO 181.13 Dwelling or Garden:Provide skip or equivalent for removal of excessive

domestic rubbish, furniture, carpets and non-approved fittings to approved tip or recycling centre including costs of landfill tax, (only to be charged when specifically instructed by Client Representative).

460037 X DWELLING:MOVE CONTENTS TO STORE IT 78.78 Dwelling:Additional cost for removing furniture, carpets and other

contents as designated by Client Representative to secure storage provided by Contractor, store for upto 42 days and later hand over to former Tenant or their representatives.

460039 X DWELLING:MOVE DISPOSE CONTENTS TO STORE IT 135.53 Dwelling:Additional cost for removing furniture, carpets and other

contents as designated by Client Representative to secure storage provided by Contractor, store for upto 42 days and later when instructed, dispose to tip.

460041 U GARDEN:LABOUR AND SKIP FOR RUBBISH NO 338.69 Garden:Provide labour, skip or equivalent for removal of environmentally

unsound material, fly tipping, scrap metal, tenants debris etc., from garden areas to approved tip or recycling centre including landfill tax (per skip).

External Communal Clearance 460101 U GARDEN OR COMMUNAL AREA:LABOUR SKIP RUBBISH NO 345.93 Garden or Communal Area:Provide labour, skip or equivalent for removal

of environmentally unsound material, fly tipping, scrap metal, tenants debris etc., from communal garden, bin stores, communal staircases, balcony access decks and the like, garages and hard paved areas to approved tip or recycling centre including landfill tax, wash down and disinfect as necessary (per skip).

Page 201: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

167 Local Space Housing

460103 U GARDEN OR COMMUNAL AREA:LABOUR MINI-SKIP RUBBISH NO 203.88 Garden or Communal Area:Provide labour, mini-skip or equivalent for

removal of environmentally unsound material, fly tipping, scrap metal, tenants debris etc., from communal garden, bin stores, communal staircases, balcony access decks and the like, garages and hard paved areas to approved tip or recycling centre including landfill tax, wash down and disinfect as necessary (per mini-skip).

External Garden Clearance and Works Turfing 460401 X TURF:RENEW SM 7.31 Turf:Lift existing mown turf, make good existing area with top soil,

removal of spoil to tip including landfill tax, lay new "Standard" quality turves, with broken joints tight to its neighbour, roll and brush-in sandy compost

460403 X TURF:CLEAR BONFIRE LAY NEW TURF SM 14.50 Turf:Clear bonfire areas of all debris including metal, timber, broken glass

and rubbish, also all unburnt material scattered over adjacent areas, sweep up ashes and the like, removal of debris to approved tip or recycling centre including landfill tax, dig out area of grass affected and lay new turves.

Shrubs 460451 X SHRUB:PRUNE NO 4.98 Shrub:Prune any variety of shrub, by hand or using power hedge trimmer

including raking up cuttings and removal of debris to approved tip or recycling centre including landfill tax.

460453 X SHRUB:DIG OUT OVERGROWN NO 16.31 Shrub:Dig out any size of overgrown shrub including roots, including

levelling ground and remove all old shrub material to approved tip or recycling centre including landfill tax.

Hedges 460461 X HEDGES:CUT OVERGROWN LM 9.60 Hedges:Cut back and neatly trim top and sides of overgrown hedge and

remove all clippings from site to approved tip or recycling centre including landfill tax.

Trees 460471 X TREE:PRUNE IT 22.11 Trees:Prune base and side growth for a height not exceeding 2.40m high

of tree including basal growth and suckers, including painting at pruning cuts with approved compound and remove all clippings from site to approved tip or recycling centre including landfill tax.

460473 X TREE:CUT DOWN GIRTH UPTO 450MM IT 236.48 Trees:Cut down existing trees of girth upto 450mm, dig out or stump

grind out the stump and roots and dispose of whole tree to approved tip or recycling centre including landfill tax; fill the resultant hole with approved material, and remove waste and debris.

Page 202: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

168 Local Space Housing

460475 X TREE:DIG OUT SEEDLING UPTO 150 MM GIRTH IT 39.41 Trees:Dig out seedling trees upto 150mm girth including roots, including

levelling ground and remove all debris off site to approved tip or recycling centre including landfill tax.

Fence Lines 460481 X FENCE LINE:STRIM TO CLEAR LM 3.50 Fence Line:Strim to clear fence line of undergrowth etc, and remove all

debris off site to approved tip or recycling centre including landfill tax.

Environmental Domestic Waste Clearance The following Schedule of Rates items are in respect of the

disposal to approved waste transfer sites of environmental waste left by Previous Tenants, these rates are not to be claimed for the disposal of debris, rubbish, waste materials, packaging’s and the like etc arising from undertaking the Works

460201 U DOMESTIC WASTE CLEARANCE:FRIDGES, FREEZERS NO 35.00 Domestic Waste Clearance:Environmental waste disposal of previous

tenants domestic fridges, fridge/freezers, upright and chest freezers to approved disposal site including cost of landfill tax, (per appliance). [only to be charged when instructed by Client Representative]

460203 U DOMESTIC WASTE CLEARANCE:CALOR GAS BOTTLES NO 10.00 Domestic Waste Clearance:Environmental waste disposal of previous

tenants calor gas bottles to approved disposal site including cost of landfill tax, (per bottle). [minimum order value will not apply unless this is sole item of works on the Works Order] [only to be charged when instructed by Client Representative]

460205 U DOMESTIC WASTE:TV’S AND COMPUTER MONITORS NO 7.00 Domestic Waste Clearance:Environmental waste disposal of previous

tenants television screens and computer monitors to approved disposal site including cost of landfill tax, (per item). [minimum order value will not apply unless this is sole item of works on the Works Order] [only to be charged when instructed by Client Representative]

460207 U DOMESTIC WASTE:COMPUTER DESK TOP UNITS NO 9.00 Domestic Waste Clearance:Environmental waste disposal of previous

tenants computer desk top unit or cpu’s to approved disposal site including cost of landfill tax, (per item). [minimum order value will not apply unless this is sole item of works on the Works Order] [only to be charged when instructed by Client Representative]

460209 U DOMESTIC WASTE CLEARANCE:CAR TYRES NO 4.50 Domestic Waste Clearance:Environmental waste disposal of previous

tenants car or van tyres with or without rims to approved disposal site including cost of landfill tax, (per tyre). [minimum order value will not apply unless this is sole item of works on the Works Order] [only to be charged when instructed by Client Representative]

460211 U DOMESTIC WASTE:CAR OR VAN BATTERIES NO 6.00 Domestic Waste Clearance:Environmental waste disposal of previous

tenants car or van batteries to approved disposal site including cost of landfill tax, (per battery). [minimum order value will not apply unless this is sole item of works on the Works Order] [only to be charged when instructed by Client Representative]

Page 203: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

169 Local Space Housing

460213 U DOMESTIC WASTE CLEARANCE:COOKERS NO 12.00 Domestic Waste Clearance:Environmental waste disposal of previous

tenants domestic cookers, built in ovens or hobunits, to approved disposal site including cost of landfill tax, (per appliance – built in oven with separate hobunit will be treated as one appliance). [minimum order value will not apply unless this is sole item of works on the Works Order] [only to be charged when instructed by Client Representative]

460215 U DOMESTIC WASTE CLEARANCE:FLUORESCENT TUBES NO 1.00 Domestic Waste Clearance:Environmental waste disposal of previous

tenants fluorescent tubes to approved disposal site including cost of landfill tax, (per tube). [minimum order value will not apply unless this is sole item of works on the Works Order] [only to be charged when instructed by Client Representative]

460217 U DOMESTIC WASTE CLEARANCE:PAINT CANS NO 0.50 Domestic Waste Clearance:Environmental waste disposal of previous

tenants paint cans to approved disposal site including cost of landfill tax, (per can). [minimum order value will not apply unless this is sole item of works on the Works Order] [only to be charged when instructed by Client Representative]

Environmental Communal Waste Clearance The following Schedule of Rates items are in respect of the

disposal to approved waste transfer sites of environmental waste left as a result of Fly Tipping, these rates are not to be claimed for the disposal of debris, rubbish, waste materials, packaging’s and the like etc arising from undertaking the Works

460301 U COMMUNAL WASTE CLEARANCE:FRIDGES, FREEZERS NO 65.81 Communal Waste Clearance:Environmental waste disposal of fly tipped

domestic fridges, fridge/freezers, upright and chest freezers to approved disposal site including cost of landfill tax, (per appliance). [only to be charged when instructed by Client Representative]

460303 U COMMUNAL WASTE CLEARANCE:CALOR GAS BOTTLES NO 24.11 Communal Waste Clearance:Environmental waste disposal of fly tipped

calor gas bottles to approved disposal site including cost of landfill tax, (per bottle). [minimum order value will not apply unless this is sole item of works on the Works Order] [only to be charged when instructed by Client Representative]

460305 U COMMUNAL WASTE:TV’S AND COMPUTER MONITORS NO 17.41 Communal Waste Clearance:Environmental waste disposal of fly tipped

television screens and computer monitors to approved disposal site including cost of landfill tax, (per item). [minimum order value will not apply unless this is sole item of works on the Works Order] [only to be charged when instructed by Client Representative]

460307 U COMMUNAL WASTE:COMPUTER DESK TOP UNITS NO 14.60 Communal Waste Clearance:Environmental waste disposal of fly tipped

computer desk top unit or cpu’s to approved disposal site including cost of landfill tax, (per item). [minimum order value will not apply unless this is sole item of works on the Works Order] [only to be charged when instructed by Client Representative]

Page 204: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

170 Local Space Housing

460309 U COMMUNAL WASTE CLEARANCE:CAR TYRES NO 13.10 Communal Waste Clearance:Environmental waste disposal of fly tipped

car or van tyres with or without rims to approved disposal site including cost of landfill tax, (per tyre). [minimum order value will not apply unless this is sole item of works on the Works Order] [only to be charged when instructed by Client Representative]

460311 U COMMUNAL WASTE:CAR OR VAN BATTERIES NO 15.41 Waste Clearance:Environmental waste disposal of fly tipped car or van

batteries to approved disposal site including cost of landfill tax, (per battery). [minimum order value will not apply unless this is sole item of works on the Works Order] [only to be charged when instructed by Client Representative]

460313 U COMMUNAL WASTE CLEARANCE:COOKERS NO 27.81 Communal Waste Clearance:Environmental waste disposal of fly tipped

domestic cookers, built in ovens or hobunits, to approved disposal site including cost of landfill tax, (per appliance – built in oven with separate hobunit will be treated as one appliance). [minimum order value will not apply unless this is sole item of works on the Works Order] [only to be charged when instructed by Client Representative]

460315 U COMMUNAL WASTE CLEARANCE:FLUORESCENT TUBES NO 3.26 Communal Waste Clearance:Environmental waste disposal of fly tipped

fluorescent tubes to approved disposal site including cost of landfill tax, (per tube). [minimum order value will not apply unless this is sole item of works on the Works Order] [only to be charged when instructed by Client Representative]

460317 U COMMUNAL WASTE CLEARANCE:PAINT CANS NO 3.76 Communal Waste Clearance:Environmental waste disposal of fly tipped

paint cans to approved disposal site including cost of landfill tax, (per can). [minimum order value will not apply unless this is sole item of works on the Works Order] [only to be charged when instructed by Client Representative]

Carpet Cleaning 460507 R CARPET:CLEAN TO ROOM UPTO 20SM CEILING AREA IT 58.87 Carpet:Thoroughly clean, scrub as necessary vacuum carpet including dry

by dehumidifier to room upto 20.00sm ceiling area.

460509 R CARPET:CLEAN TO HALL STAIRS IT 58.32 Carpet:Thoroughly clean, scrub as necessary vacuum carpet including dry

by dehumidifier to hall, landing and staircase area complete.

460511 R CARPET:CLEAN TO HALL IT 35.72 Carpet:Thoroughly clean, scrub as necessary vacuum carpet including dry

by dehumidifier to hall area complete.

Disinfestation 461001 X DWELLING:DISINFESTATION WORKS IT 104.23 Dwelling:Seal and secure void dwelling and carry out disinfestation works.

Page 205: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

171 Local Space Housing

Waste Chutes - Repairs 463001 R WASTE CHUTE:INSPECT TAKE DOWN REPAIR NO 26.38 Waste Chute:Inspect, take down, repair, overhaul, refix, ease and adjust

dust chute hopper.

463003 R WASTE CHUTE:CLEAR OUT BLOCKAGE (PER FLOOR) IT 19.70 Waste Chute:Clean out blocked chute and remove debris (per floor).

Page 206: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

172 Local Space Housing

GLAZING Reglaze Doors and Windows Glass - Clear and Obscured 515005 U PANE:REGLAZE 4MM CLEAR OR OBSCURE UPTO 1.00SM NO 77.01 Pane:Reglaze single pane in 4mm clear or obscure glass, upto

1.00sm, hack out and glaze with putty, sprigs, clips or beads at any level, touch up paintwork to match existing and remove waste and debris.

515007 U PANE:REGLAZE 4MM CLEAR OR OBSCURE OVER 1.00SM SM 84.88 Pane:Reglaze single pane in 4mm clear or obscure glass, over

1.00sm, hack out and glaze with putty, sprigs, clips or beads at any level, touch up paintwork to match existing, and remove waste and debris.

515013 U PANE:REGLAZE 6MM CLEAR OR OBSCURE UPTO 1.00SM NO 103.40 Pane:Reglaze single pane in 6mm clear or obscure glass, upto

1.00sm, hack out and glaze with putty, sprigs, clips or beads at any level, touch up decoration to match existing, and remove waste and debris.

515015 U PANE:REGLAZE 6MM CLEAR OR OBSCURE OVER 1.00SM SM 109.97 Pane:Reglaze single pane in 6mm clear or obscure glass, over

1.00sm, hack out and glaze with putty, sprigs, clips or beads at any level, touch up decoration to match existing, and remove waste and debris.

Glass - Georgian Wired Cast 520005 U PANE:REGLAZE 7MM GWCG UPTO 1.00SM NO 87.01 Pane:Reglaze single pane in 7mm georgian wired cast glass, upto

1.00sm, hack out and glaze with putty, sprigs, clips or beads at any level, touch up decoration to match existing, and remove waste and debris.

520007 U PANE:REGLAZE 7MM GWCG OVER 1.00SM SM 94.01 Pane:Reglaze single pane in 7mm georgian wired cast glass, over

1.00sm, hack out and glaze with putty, sprigs, clips or beads at any level, touch up decoration to match existing, and remove waste and debris.

Glass - Georgian Wired Polished 525005 U PANE:REGLAZE 6MM GWPP UPTO 1.00SM NO 146.09 Pane:Reglaze single pane in 6mm georgian wired polished plate

glass upto 1.00sm, hack out and glaze with putty, sprigs, clips or beads at any level, touch up decoration to match existing, and remove waste and debris.

525007 U PANE:REGLAZE 6MM GWPP OVER 1.00SM SM 153.09 Pane:Reglaze single pane in 6mm georgian wired polished plate

glass over 1.00sm, hack out and glaze with putty, sprigs, clips or beads at any level, touch up decoration to match existing, and remove waste and debris.

Page 207: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

173 Local Space Housing

Glass - Toughened 530005 R PANE:REGLAZE 6MM TOUGHENED UPTO 1.00SM NO 145.41 Pane:Reglaze single pane in 6mm toughened safety glass upto

1.00sm, hack out and glaze with putty, sprigs, clips or beads at any level, touch up decoration to match existing, and remove waste and debris.

530007 R PANE:REGLAZE 6MM TOUGHENED OVER 1.00SM SM 153.29 Pane:Reglaze single pane in 6mm toughened safety glass, over

1.00sm, hack out and glaze with putty, sprigs, clips or beads at any level, touch up decoration to match existing, and remove waste and debris.

Glass - Laminated 535005 R PANE:REGLAZE 6.4MM LAMINATED UPTO 1.00SM NO 135.24 Pane:Reglaze single pane in 6.4mm laminated glass upto 1.00sm,

hack out and glaze with putty, sprigs, clips or beads at any level, touch up decoration to match existing, and remove waste and debris.

535007 R PANE:REGLAZE 6.4MM LAMINATED OVER 1.00SM SM 139.62 Pane:Reglaze single pane in 6.4mm laminated glass over 1.00sm,

hack out and glaze with putty, sprigs, clips or beads at any level, touch up decoration to match existing, and remove waste and debris.

535015 R PANE:REGLAZE 4.4MM LAMINATED UPTO 1.00SM NO 114.09 Pane:Reglaze single pane in 4.4mm laminated glass, upto 1.00sm,

hack out and glaze with putty, sprigs, clips or beads at any level, touch up decoration to match existing, and remove waste and debris.

535017 R PANE:REGLAZE 4.4MM LAMINATED OVER 1.00SM SM 121.97 Pane:Reglaze single pane in 4.4mm laminated glass, over 1.00sm

hack out and glaze with putty, sprigs, clips or beads at any level, touch up decoration to match existing, and remove waste and debris.

Glass - Polycarbonate 540005 U PANE:REGLAZE 4MM POLYCARBONATE UPTO 1.00SM NO 128.67 Pane:Reglaze single pane in 4mm polycarbonate upto 1.00sm, hack

out and glaze with putty, sprigs, clips or beads at any level, touch up decoration to match existing, and remove waste and debris.

540007 U PANE:REGLAZE 4MM POLYCARBONATE OVER 1.00SM SM 133.05 Pane:Reglaze single pane in 4mm polycarbonate glass, over 1.00sm

hack out and glaze with putty, sprigs, clips or beads at any level, touch up decoration to match existing, and remove waste and debris.

Page 208: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

174 Local Space Housing

Double Glazed Units - Clear Float Low Emissivity (Low E) Glass

551005 R DOUBLE GLAZED UNIT:REGLAZE UPTO 1.00SM-CLEAR LOW E NO 123.80 Double Glazed Unit:Reglaze unit upto 1.00sm, hermetically sealed

with 4mm clear float low emissivity (Low E) glass flush edge unit, including remove beads etc and set aside, hack out glass and glaze new unit to wood, metal or PVCu frames, touch up decoration as necessary to match existing, and remove waste and debris.

551007 R DOUBLE GLAZED UNIT:REGLAZE OVER 1.00SM-CLEAR LOW E SM 128.18 Double Glazed Unit:Reglaze unit over 1.00sm with hermetically

sealed with 4mm clear float low emissivity (Low E) glass flush edge unit, including remove beads etc and set aside, hack out glass and glaze new unit to wood, metal or PVCu frames, touch up decoration as necessary to match existing, and remove waste and debris.

Double Glazed Units - Safety Low Emissivity (Low E) Glass 556005 R DOUBLE GLAZED UNIT:REGLAZE UPTO 1.00SM-SAFETY LOW E NO 175.88 Double Glazed Unit:Reglaze unit upto 1.00sm, hermatically sealed

with 4mm safety low emissivity (Low E) glass flush edge unit, including remove beads etc., hack out glass and glaze new unit to wood, metal or PVCu frames, touch up decoration as necessary to match existing, and remove waste and debris.

556007 R DOUBLE GLAZED UNIT:REGLAZE OVER 1.00SM-SAFETY LOW E SM 180.26 Double Glazed Unit:Reglaze unit over 1.00sm with hermetically

sealed 4mm safety low emissivity (Low E) glass flush edge unit, including remove beads etc., hack out glass and glaze new unit to wood, metal or PVCu frames, touch up decoration as necessary to match existing, and remove waste and debris.

Double Glazing Repairs 573091 R CONDENSATION DRIP TRAY:RENEW IT 34.56 Condensation Drip Tray:Carefully remove any size of double glazed unit,

dismantle and renew condensation drip tray, reinstall double glazed unit including renewing any gaskets as necessary.

573093 R DOUBLE GLAZED UNITS:REFIX NO 40.48 Double Glazed Unit:Carefully remove any size of double glazed unit,

renew gaskets as necessary, and refix including rebedding in silicone.

Domelights 560001 R DOMELIGHT:REMOVE AND REFIX NO 70.68 Domelight:Take off and refix domelight ne 1219x1219mm including

all necessary drilling and plugging and redressing of upstands and flashings.

560003 R DOMELIGHT:RENEW 610X610MM COMPLETE NO 249.26 Domelight:Renew 610x610mm translucent glass fibre reinforced

domelight including all necessary drilling and plugging and renewal as necessary of flashings and upstands.

560005 R DOMELIGHT:RENEW 914X914MM COMPLETE NO 302.18 Domelight:Renew 914x914mm translucent glass fibre reinforced

domelight including all necessary drilling and plugging and renewal as necessary of flashings and upstands.

Page 209: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

175 Local Space Housing

560007 R DOMELIGHT:RENEW 1210X1210MM COMPLETE NO 333.54 Domelight:Renew 1210x1210mm translucent glass fibre reinforced

domelight including all necessary drilling and plugging and renewal as necessary of flashings and upstands.

Mirrors 565001 R MIRROR:RENEW 450X450X4MM NO 38.48 Mirror:Renew 450x450x4mm silvered float glass mirror with

polished edges and predrilled holes and fix to any background including all drilling and plugging and making good, and remove waste and debris.

565003 R MIRROR:RENEW 900X600X4MM NO 73.76 Mirror:Renew 900x600x4mm silvered float glass mirror with

polished edges and predrilled holes and fix to any background including all drilling and plugging and making good, and remove waste and debris.

Shower Screens 570001 R SHOWER SCREEN:REFIX GLASS OVER BATH SCREEN NO 14.22 Shower Screen:Refix loose framed glass over bath shower screen

including all necessary drilling and plugging and making good.

570003 R SHOWER SCREEN:RENEW GLASS OVER BATH NO 187.16 Shower Screen:Renew framed glass over bath shower screen

including remove existing, drill and plug as necessary and fit new screen including all making good.

570011 R SHOWER SCREEN:RENEW TWO SIDED GLASS SCREEN IT 502.52 Shower Screen:Renew any two sided framed glass shower screen

and door complete to individual cubicle above shower tray, remove existing, drill and plug as necessary and fit new screen including all making good.

570013 R SHOWER SCREEN:RENEW THREE SIDED GLASS SCREEN IT 665.65 Shower Screen:Renew any three sided framed glass shower screen

and door complete to individual cubicle above shower tray, remove existing, drill and plug as necessary and fit new screen including all making good.

570015 R SHOWER SCREEN:REFIX GLASS SIDE PANEL IT 16.13 Shower Screen:Refix loose framed glass shower cubicle side

panel including all necessary drilling and plugging and make good.

570017 R SHOWER SCREEN:REFIX OR REPAIR DOOR IT 20.13 Shower Screen:Refix or repair loose framed glass shower door

and make good.

Sundries 575001 R PUTTY:RENEW DEFECTIVE PUTTY LM 4.67 Putty:Renew loose or defective putty, hack out old, prepare and

apply new putty and touch up paintwork to match existing, and remove waste and debris.

Page 210: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

176 Local Space Housing

575003 R BEAD:RENEW DEFECTIVE GLAZING BEAD LM 9.43 Bead:Renew any type of defective glazing bead including remove

existing bead, clean, prepare and supply and fit new bead to match existing including all cutting, mitres, sealing with silicone sealant as necessary and redecoration.

575005 R BEAD:APPLY SILICONE SEAL TO GLAZING BEAD LM 6.19 Bead:Seal around glazing bead with silicone sealant including

remove existing bead, clean and prepare rebate and refix bead including touch up paintwork to match existing, and remove waste and debris.

575007 R WINDOW:BED EDGES IN WASHLEATHER STRIP LM 3.11 Window:Extra for bedding edges of glass in washleather strip

including sealing externally with putty.

575009 R GASKETS:EXTRA OVER FOR COMPRESSION GASK LM 2.05 Gaskets:Extra over reglazing or renewal items for glazing to any

metal or PVCu frame with compression gaskets instead of putty or beads.

575011 R VENT:RENEW CIRCULAR TO EXISTING OPENING NO 17.93 Vent:Renew circular vent to existing opening including carefully

remove existing plastic ventilator and fit new ventilator, glass breakage is contractors risk.

575013 R VENT:FIT NEW CIRCULAR TO EXISTING GLASS NO 33.25 Vent:Fit new circular vent to existing glass including carefully cut

hole in glass and fit new ventilator, glass breakage is contractors risk.

575015 R VENT:FIT METAL PERMAVENT NO 38.92 Vent:Supply and fit metal ‘Permavent’ to window including scribing

to line, knock out glass and install vent, glass breakage is contractors risk.

575017 R LOUVRE:RENEW BLADE NE 950MM LONG NO 20.80 Louvre:Renew 6mm glass louvre blade ne 950mm long with

polished edges including remove existing blade and bed/clip into jamb.

575019 R TEMPORARY GLAZING:FIX PRIOR TO REPLACEMENT UNIT NO 28.86 Temporary Glazing:Provide and fix temporary glazing or boarding

prior to the replacement of double glazed unit including hack out, bed and seal as necessary.

575021 R SYLGLAS:FIT TAPE NE 100MM WIDE LM 7.86 Sylglas:Prepare and apply ‘Sylglas’ tape ne 100mm wide as

temporary repair.

575023 R WINDOW:APPLY SOLAR REFLECTIVE FILM SM 89.01 Window:Prepare and apply solar reflective film to glass surfaces

including all cutting and fitting to edges.

575025 R WINDOW:APPLY SAFETY FILM. SM 74.89 Window:Prepare and apply safety film to glass surfaces including all

cutting and fitting to edges.

Page 211: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

177 Local Space Housing

575027 U SASH:EXTRA OVER GLAZING TO DISMANTLE SASH NO 72.92 Sash:Any reglazing works to windows of any type or size for

removing sash or casement, dismantling, rebuilding and later refitting, making good all disturbed (can only be claimed if instructed by the Client Representative).

Curtains 575501 X NET CURTAIN:SUPPLY SINGLE WIDTH SM 7.54 Net Curtain:Supply and install new single width, full height net

curtains, hemmed all edges, to glazed opening of any type or size, on and including proprietary hanging rods or PVC coated tension wire with hooks, eyes, support brackets as appropriate and fixing to any background, make good as necessary (measured length of support by net curtain height).

Page 212: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

178 Local Space Housing

PLUMBING Rainwater Pipework Rainwater Pipework - PVCu 601101 R DOWNPIPE:RENEW PVCU NE 2 STOREY IT 104.48 Downpipe:Renew round or square PVCu downpipe to ne 2 storey

dwelling complete with new brackets plugged to brickwork and all necessary branches, offset projections, hopperhead, shoe, terminal and slate if required including all cutting and making joints and make good to structure and all finishes, and remove waste and debris.

601103 R DOWNPIPE:RENEW PVCU 2-4 STOREY IT 188.95 Downpipe:Renew round or square PVCu downpipe to over 2, ne 4

storey dwelling complete with new brackets plugged to brickwork and all necessary branches, offset projections, hopperhead, shoe, terminal and slate if required including all cutting and making joints and make good to structure and all finishes, and remove waste and debris.

601105 R DOWNPIPE:RENEW PVCU PIPE LM 17.98 Downpipe:Renew round or square PVCu downpipe, remove and

refix or renew pipe brackets plugged and screwed to brickwork including cutting and making joints, make good to structure and finishes, and remove waste and debris.

601107 R DOWNPIPE:RENEW NE 300MM PVCU OFFSET NO 30.57 Downpipe:Renew any type of PVCu offset, ne 300mm projection

including all cutting and remake joints, make good to structure and finishes, and remove waste and debris.

601109 R DOWNPIPE:RENEW PVCU HOPPERHEAD NO 25.37 Downpipe:Renew PVCu downpipe hopperhead for round or square

downpipe, plugged and screwed to brickwork including all cutting and remake joints, make good to structure and finishes, and remove waste and debris.

601111 R DOWNPIPE:RENEW PVCU SHOE NO 9.44 Downpipe:Renew any type of PVCu downpipe shoe plugged and

screwed to brickwork including all cutting and remake joints, make good to structure and finishes, and remove waste and debris.

601113 R DOWNPIPE:RENEW PVCU BRANCH NO 30.09 Downpipe:Renew round or square PVCu branch including all cutting

and making joints, make good to structure and finishes, and remove waste and debris.

601125 R DOWNPIPE:REMAKE PVCU JOINTS OR REFIX FITTING IT 11.63 Downpipe:Remake any loose or leaking PVCu downpipe joint or

joints to any fitting, renew drain connection adaptor or remake joint to drain or gully connection, make good (per downpipe)

601119 R DOWNPIPE:RENEW OR REFIX PVCU CLIP NO 5.98 Downpipe:Refix or renew clip to PVCu downpipe plugged and

screwed to brickwork and make good to structure and finishes, and remove waste and debris.

Page 213: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

179 Local Space Housing

601121 R DOWNPIPE:REMOVE AND REFIX PVCU COMPLETE LM 15.89 Downpipe:Take down any PVCu downpipe, remove and refix pipe

brackets, plugged and screwed to brickwork and refix downpipes including all hopperheads offsets, shoes and remake all joints, make good to structure and finishes, and remove waste and debris.

Rainwater Pipework - Cast Iron Repairs 601503 R DOWNPIPE:RENEW UPTO 100MM CAST IRON PIPE IT 103.50 Downpipe:Renew length of upto 100mm diameter cast iron

downpipe, remove and refix or renew pipe brackets plugged and screwed to brickwork including cutting and making joints, make good to structure and finishes and decorate to match existing, and remove waste and debris.

601505 R DOWNPIPE:REMOVE AND REFIX CAST IRON COMPLETE LM 21.51 Downpipe:Take down any cast iron downpipe, remove and refix

pipe brackets, plugged and screwed to brickwork and refix downpipes including all hopper heads, offsets, branches, shoes and remake all joints, make good to structure and finishes and touch up decorations to match existing, and remove waste and debris.

601507 R DOWNPIPE:RENEW CAST IRON PIPE BRACKET NO 30.17 Downpipe:Renew any diameter cast iron downpipe bracket plugged

and screwed to brickwork, make good to structure and finishes and decorate to match existing, and remove waste and debris.

601509 R DOWNPIPE:REFIX LOOSE CAST IRON BRACKET NO 5.49 Downpipe:Refix loose cast iron downpipe bracket, including

replugging and screwing to brickwork, make good to structure and finishes and decorate to match existing, and remove waste and debris.

601511 R DOWNPIPE:REMAKE CAST IRON JOINTS IT 13.28 Downpipe:Remake any loose or leaking cast iron downpipe joint or

joints to any fitting, make good to structure and finishes and decorate to match existing, and remove waste and debris.

Rainwater Gutters Rainwater Gutters - PVCu 603101 R GUTTER:RENEW 112MM PVCU COMPLETE LM 31.73 Gutter:Renew any gutter with ne 112mm PVCu gutter of any profile

including support brackets fixed to fascia complete with all necessary angles, outlets stop ends, including cutting, making gutters line and level and connections to existing guttering and downpipes, and remove waste and debris.

603103 R GUTTER:RENEW 150MM PVCU COMPLETE LM 41.86 Gutter:Renew any gutter with 150mm PVCu gutter of any profile

including support brackets fixed to fascia complete with all necessary angles, outlets stop ends, including cutting, making gutters line and level and connections to existing guttering and downpipes, and remove waste and debris.

Page 214: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

180 Local Space Housing

603105 R GUTTER:RENEW 112MM PVCU LM 20.08 Gutter:Renew ne 112mm PVCu gutter of any profile, including

support brackets fixed to fascia including cutting, making joints, line and level and connection to existing guttering and remove waste and debris.

603107 R GUTTER:RENEW 150MM PVCU LM 27.02 Gutter:Renew 150mm PVCu gutter of any profile, including support

brackets fixed to fascia including cutting, making joints, line and level and connection to existing guttering and remove waste and debris.

603109 R GUTTER:REALIGN PVCU GUTTER LM 8.52 Gutter:Take down any PVCu gutter, remove and refix brackets to

fascia and refix gutter to brackets to line and level including all angles, outlets and stop ends and remake all joints.

603111 R GUTTER:RENEW PVCU STOP END NO 6.89 Gutter:Renew ne 112mm PVCu gutter stop end of any profile,

including remaking joints and line and level and remove waste and debris..

603115 R GUTTER:RENEW PVCU OUTLET NO 12.10 Gutter:Renew ne 112mm PVCu gutter outlet of any profile,

including remaking joints and line and level, and remove waste and debris.

603119 R GUTTER:RENEW PVCU ANGLE NO 12.56 Gutter:Renew ne 112mm PVCu gutter angle of any profile including

remaking joints and line and level, and remove waste and debris.

603123 R GUTTER:RENEW PVCU UNION NO 11.36 Gutter:Renew ne 112mm PVCu gutter union or fitting rubbers of

any profile including remake joints and line and level, and remove waste and debris.

603127 R GUTTER:RENEW PVCU BRACKET NO 6.35 Gutter:Renew ne 112mm PVCu gutter bracket of any profile

including remaking joints and line and level, and remove waste and debris.

603131 R GUTTER:TAKE DOWN AND REFIX PVCU OUTLET NO 7.85 Gutter:Take down any PVCu gutter outlet and refix and remake

joints.

603133 R GUTTER:REMAKE PVCU JOINT NO 5.28 Gutter:Remake any loose or leaking PVCu gutter joint or joints

to fittings including break joint, clean out and make joint, and line and level.

Rainwater Gutters - Cast Iron 603301 R GUTTER:RENEW IN CAST IRON COMPLETE LM 59.21 Gutter:Renew ne 125mm cast iron gutter of any profile including

support brackets fixed to fascia complete with all necessary angles, outlets and stop ends, including cutting, making gutters line and level, and connections to existing guttering, and rub down, prepare for and decorate to outside of gutter and one coat of bitumastic paint to inside of gutter, and remove waste and debris.

Page 215: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

181 Local Space Housing

603303 R GUTTER:RENEW LENGTH OF CAST IRON LM 66.97 Gutter:Renew ne 125mm cast iron gutter of any profile including

support brackets fixed to fascia including cutting, making joints, line and level, and connections to existing guttering, and rub down, prepare for and decorate to match existing to outside of gutter and one coat of bitumastic paint to inside of gutter, and remove waste and debris.

603305 R GUTTER:REALIGN CAST IRON GUTTER LM 11.12 Gutter:Take down any cast iron gutter, remove and refix brackets

to fascia and refix gutter to brackets, including all angles, outlets and stop ends, remake all joints and touch up decorations.

603307 R GUTTER:RENEW CAST IRON STOP END NO 18.26 Gutter:Renew ne 125mm cast iron gutter stop end of any profile,

including remaking joint, line and level, rub down, prepare for and decorate to match existing to outside and one coat of bitumastic paint to inside, and remove waste and debris.

603309 R GUTTER:RENEW CAST IRON OUTLET NO 38.51 Gutter:Renew ne 125mm cast iron gutter outlet of any profile,

including remaking joint, line and level, rub down, prepare for and decorate to match existing to outside and one coat of bitumastic paint to inside, and remove waste and debris.

603311 R GUTTER:RENEW CAST IRON ANGLE NO 38.36 Gutter:Renew ne 125mm cast iron gutter angle of any profile,

including remaking joint, line and level, rub down, prepare for and decorate to match existing to outside and one coat of bitumastic paint to inside, and remove waste and debris.

603313 R GUTTER:RENEW CAST IRON UNION NO 33.10 Gutter:Renew ne 125mm cast iron gutter Union of any profile,

including remaking joint, line and level, rub down, prepare for and decorate to match existing to outside and one coat of bitumastic paint to inside, and remove waste and debris.

603315 R GUTTER:RENEW CAST IRON BRACKET NO 19.59 Gutter:Renew gutter bracket for cast iron gutter including line and

level, and rub down, prepare for and decorate to match existing, and remove waste and debris.

603317 R GUTTER:TAKE DOWN AND REFIX CAST IRON OUTLET NO 26.22 Gutter:Take down any cast iron gutter outlet and refix, remake all

joints, and touch up decorations

603319 R GUTTER:REMAKE CAST IRON JOINTS NO 11.84 Gutter:Remake any cast iron gutter joint including break joint, clean

out and make joint, and touch up decorations.

Gutters/Downpipes - Clean Out 603901 R DOWNPIPE:CLEAR BLOCKAGE NE 2 STOREY IT 11.43 Downpipe:Clear blockage from downpipe ne 2 storey including gain

access, rod, flush out and test including clean out gulley and remove debris from site on completion (not to be claimed with 603903)

Page 216: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

182 Local Space Housing

603902 R DOWNPIPE:CLEAR BLOCKAGE 2 TO 4 STOREY IT 23.39 Downpipe:Clear blockage from downpipe any 2 to 4 storey

including gain access, rod, flush out and test including clean out gulley and remove debris from site on completion (not to be claimed with 603903)

603903 R GUTTER:CLEAN AND FLUSH OUT PER ELEVATION IT 23.39 Gutter:Clean out debris from gutters to any type of property

including flush out and test, rod downpipe including clean out gulley and remove debris from site on completion (per elevation).

603905 R HOPPER:CLEAR OUT BLOCKED HOPPERHEAD NO 9.35 Hopper:Clear out blocked hopperhead including rod if necessary,

flush out and test and remove debris from site on completion, and remove waste and debris.

603907 R FLAT ROOF OUTLET:CLEAR BLOCKED IT 12.99 Flat Roof Outlet:Clear out blocked flat roof outlet including rod if

necessary, flush out and test and remove debris from site on completion, and remove waste and debris.

Foul Drainage Above Ground Soil and Vent Stacks - External - PVCu 610101 R STACK:RENEW EXTERNAL PVCU COMPLETE NE 2 STOREY IT 333.55 Stack:Take down external soil stack complete to any dwelling ne 2

storey and renew with 110mm PVCu pipework complete with all necessary wc branches, bends, offsets, waste bosses, pipes, brackets, access pipes, drain connector, terminal and slate if necessary including all cutting and making joints, fixing to any background, make good to structure including roofing, soffit or similar and make good to all finishes and test, and remove waste and debris.

610103 R STACK:RENEW EXTERNAL PVCU COMPLETE 2 TO 4 STOREY IT 515.79 Stack:Take down external soil stack complete to any dwelling over

2, ne 4 storey and renew with 110mm PVCu pipework complete with all necessary wc branches, bends, offsets, waste bosses, pipes, brackets, access pipes, drain connector, terminal and slate if necessary including all cutting and making joints, fixing to any background, make good to structure including roofing, soffit or similar and make good to all finishes and test, and remove waste and debris.

610105 R STACK:RENEW EXTERNAL 110MM PVCU SOIL STACK LM 20.96 Stack:Renew 110mm diameter PVCu length or section of external

soil stack, renew or refix clips as necessary, including cut and make joints, make good to structure and finishes and test, and remove waste and debris.

610107 R STACK:RENEW EXTERNAL PVCU SOIL STACK BRACKET NO 7.56 Stack:Renew 110mm diameter external PVCu soil stack pipe bracket

securely plugged and screwed to any background, make good to structure and finishes and test, and remove waste and debris.

Page 217: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

183 Local Space Housing

610109 R STACK:RENEW EXTERNAL PVCU WC BRANCH PIPE NO 83.98 Stack:Renew 110mm diameter external PVCu soil stack wc branch

pipe with access, connect to pan, including cutting, making joints, cut holes to walls, make good to structure and finishes and test, and remove waste and debris.

610111 R STACK:RENEW EXTERNAL PVCU OFFSET NO 20.48 Stack:Renew 110mm diameter external PVCu soil stack offset

including cutting and making all necessary joints, make good to structure and finishes and test, and remove waste and debris.

610113 R STACK:RENEW EXTERNAL PVCU JUNCTION NO 43.86 Stack:Renew 110mm diameter external PVCu soil stack junction

with access including cutting and making all necessary joints, and make good to structure and finishes and test, and remove waste and debris.

610115 R STACK:RENEW EXTERNAL PVCU ACCESS BEND NO 45.29 Stack:Renew 110mm diameter external PVCu soil stack access

bend, including cutting and making all necessary joints, make good to structure and finishes and test, and remove waste and debris.

610117 R STACK:RENEW EXTERNAL PVCU ACCESS PIPE NO 25.47 Stack:Renew 110mm diameter external PVCu soil stack access pipe,

including cutting and making all necessary joints, make good to structure and finishes and test, and remove waste and debris.

610119 R STACK:RENEW EXTERNAL PVCU VENT TERMINAL NO 56.50 Stack:Renew 110mm diameter external PVCu soil stack/vent

terminal and weathering slate and make good to roofing.

610121 R STACK:RENEW EXTERNAL PVCU DOUBLE SOCKET NO 28.15 Stack:Renew 110mm diameter external PVCu soil stack double

socket, including cutting and making all necessary joints, make good to structure and finishes and test, and remove waste and debris.

610123 R STACK:RENEW EXTERNAL PVCU DRAIN CONNECTOR NO 22.14 Stack:Renew drain connection with 110mm diameter external PVCu

soil stack drainage adaptor.

610125 R STACK:RENEW EXTERNAL PVCU 110MM BOSS CONNECTOR NO 23.54 Stack:Renew 110mm diameter external PVCu soil stack boss

connector, including cutting and making all necessary joints, make good and test, and remove waste and debris.

610127 R STACK:RENEW EXTERNAL PVCU BOSS ADAPTOR NO 15.29 Stack:Renew 32mm or 40mm diameter external solvent PVCu boss

adaptor, including any additional renewal of boss pipe, and remove waste and debris.

610129 R STACK:REPAIR FRACTURE ON EXTERNAL PVCU AT SLAB IT 99.81 Stack:Repair fractured external soil outlet at slab level, break up

concrete slab, repair pipework fix new PVCu pipe or fitting with new clips, remake all joints, make good walls and floors and test (measured per pipe or fitting).

Page 218: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

184 Local Space Housing

610131 R STACK:ACCESS COVER TO EXISTING EXTERNAL PVCU IT 38.43 Stack:Insert or cut into any existing external PVCu soil stack and

provide and fix new proprietory bolted removable access covers and seals, maintain integrity of existing system by using compatible seals or solvent welding.

610133 R STACK:RENEW PVCU BALLOON GRATING NO 18.78 Stack:Renew PVCu balloon grating to soil stack. Soil and Vent Stacks - Internal - PVCu 610301 R STACK:RENEW INTERNAL PVCU COMPLETE NE 2 STOREY IT 411.50 Stack:Take down internal soil stack complete to any dwelling ne 2

storey and renew with 110mm PVCu pipework complete with all necessary fittings i.e. wc branch, bends, offsets, waste bosses, pipes, brackets, access pipes, drain connector terminal and slate if necessary including all cutting and making joints, fixing to any background, remove and refix access panels, duct casings and the like for access, make good to structure and finishes and test, and remove waste and debris.

610303 R STACK:RENEW INTERNAL PVCU COMPLETE 2-4 STOREY IT 593.74 Stack:Take down internal soil stack complete to any dwelling over 2

ne 4 storey and renew with 110mm PVCu pipework complete with all necessary wc branches, bends, offsets, waste bosses, pipes, brackets, access pipes, drain connector terminal and slate if necessary including all cutting and making joints, fixing to any background, remove and refix access panels, duct casings and the like for access, make good to structure and finishes and test, and remove waste and debris.

610305 R STACK:RENEW INTERNAL 110MM PVCU SOIL STACK LM 26.16 Stack:Renew 110mm diameter PVCu length or section of internal

soil stack, remove and refix access panels, duct casings and the like for access, renew or refix clips as necessary including cut and make joints, make good to structure and finishes and test, and remove waste and debris.

610307 R STACK:RENEW INTERNAL PVCU SOIL STACK BRACKETS NO 12.75 Stack:Renew 110mm diameter internal PVCu soil stack pipe bracket

securely plugged and screwed to any background, remove and refix access panels, duct casings and the like for access make good to structure and finishes and test, and remove waste and debris.

610309 R STACK:RENEW INTERNAL PVCU WC BRANCH PIPE NO 94.37 Stack:Renew 110mm diameter internal PVCu soil stack wc branch

pipe with access, connect to pan, including cutting, making joints, cut holes to walls, make good to structure and finishes and test, remove and refix duct casings and access panels and the like for access, and remove waste and debris.

610311 R STACK:RENEW INTERNAL PVCU OFFSET NO 25.68 Stack:Renew 110mm diameter internal PVCu soil stack offset

including cutting and making all necessary joints, make good to structure and finishes and test, remove and refix duct casings and access panels and the like for access, and remove waste and debris.

Page 219: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

185 Local Space Housing

610313 R STACK:RENEW INTERNAL PVCU JUNCTION NO 51.65 Stack:Renew 110mm diameter internal PVCu soil stack junction

with access including cutting and making all necessary joints, make good to structure and finishes test, remove and refix duct casings and access panels and the like for access, and remove waste and debris.

610315 R STACK:RENEW INTERNAL PVCU ACCESS BEND NO 50.49 Stack:Renew 110mm diameter internal PVCu soil stack access

bend, including cutting and making all necessary joints, make good to structure and finishes and test, remove and refix duct casings and access panels and the like for access, and remove waste and debris.

610317 R STACK:RENEW INTERNAL PVCU ACCESS PIPE NO 30.66 Stack:Renew 110mm diameter internal PVCu soil stack access pipe,

including cutting and making all necessary joints, make good to structure and finishes and test, remove and refix duct casings and access panels for access, and remove waste and debris.

610319 R STACK:RENEW INTERNAL PVCU DOUBLE SOCKET NO 33.87 Stack:Renew 110mm diameter internal PVCu soil stack double

socket, including cutting and making all necessary joints, make good to structure and finishes and test, remove and refix duct casings and access panels and the like for access, and remove waste and debris.

610321 R STACK:RENEW INTERNAL PVCU 110MM BOSS CONNECTOR NO 28.73 Stack:Renew 110mm diameter internal PVCu soil stack boss

connector, including cutting and making all necessary joints, make good and test, remove and refix duct casings and access panels and the like for access, and remove waste and debris.

610323 R STACK:RENEW INTERNAL PVCU BOSS ADAPTOR NO 19.45 Stack:Renew 32mm or 40mm diameter internal solvent PVCu boss

adaptor, including any additional renewal of boss pipe, remove and refix duct casings and access panels and the like for access, and remove waste and debris.

610325 R STACK:REPAIR FRACTURE ON INTERNAL PVCU AT SLAB IT 112.81 Stack:Repair fractured internal soil outlet at slab level, break up

concrete slab, repair pipework fix new PVCu pipe or fitting with new clips, remake all joints, make good walls and floors and test, remove and refix duct casings and access panels and the like for access, and remove waste and debris (measured per pipe or fitting).

610327 R STACK:ACCESS COVER TO EXISTING INTERNAL PVCU STACK IT 63.31 Stack:Insert or cut into any existing internal PVCu soil stack and

provide and fix new proprietary bolted removable access covers and seals, maintain integrity of existing system by using compatible seals or solvent welding, remove and refix duct casings and access panels and the like for acess, and remove waste and debris..

610329 R STACK:RENEW PVCU AIR ADMITTANCE VALVE IT 20.48 Stack:Renew Air Admittance Valve to PVCu internal soil stack

including gain access, remove existing and fix new to existing PVC or CI stack including either socket or adaptor as necessary, and remove waste and debris..

Page 220: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

186 Local Space Housing

610331 R STACK:REMAKE JOINT PVCU STACK NO 16.00 Stack:Remake ne 100mm diameter PVCu soil stack joint including

break joint, clean out and make joint.

Soil and Vent Stacks - Cast Iron - Repairs 610501 R STACK:RENEW NE 150MM CAST IRON NE 2M NO 135.87 Stack:RenewUpto 150mm diameter cast iron soil stack length ne

2m long with existing or new clips or ears including all cutting, remake joints, make good and decorate to match existing, and remove waste and debris.

610503 R STACK:REMAKE JOINT TO CAST IRON STACK NO 24.11 Stack:Remake ne 150mm diameter cast iron soil stack joint. 610505 R STACK:RENEW CAST IRON OFFSET NO 68.46 Stack:Renew ne 150mm diameter offset to cast iron soil stack

including remake joints and decorate to match existing, and remove waste and debris.

610507 R STACK:RENEW CAST IRON BRANCH NO 103.59 Stack:Renew ne 150mm diameter branch to cast iron soil stack

including remake joints and decorate to match existing, and remove waste and debris.

Waste Pipework and Fittings Waste Pipework and Fittings - Plastic 620101 R WASTE:RENEW 32MM PIPE AND TRAP BASIN NO 48.95 Waste:Renew waste to any sink or basin in ne 32mm plastic

pipework complete including trap, all fittings, clips, cut or form holes and make good, make all necessary connections to stack, gully or hopper head and test, and remove waste and debris.

620103 R WASTE:RENEW 40MM PIPE AND TRAP SINK NO 57.32 Waste:Renew waste to any sink or basin in ne 40mm plastic

pipework complete including trap, all fittings, clips, cut or form holes and make good, make all necessary connections to stack, gully or hopper head and test, and remove waste and debris.

620105 R WASTE:RENEW 40MM PIPE AND TRAP BATH NO 69.49 Waste:Renew waste to any bath in ne 40mm plastic pipework

complete including trap, all fittings, clips, cut or form holes and make good, make all necessary connections to stack, gully or hopper head and test, and remove waste and debris.

620107 R WASTE:RENEW 40MM PIPE AND TRAP SHOWER NO 148.56 Waste:Renew waste to any shower in ne 40mm plastic pipework

complete including sealed trap, all fittings, clips, remove and refix tray, cut and form holes and make good, make all necessary connections to stack, gully or hopper head and test, and remove waste and debris.

620117 R TRAP:RENEW 32MM SINK OR BASIN TRAP NO 12.43 Trap:Renew ne 32mm diameter plastic trap to sink or basin

including all adjustments to pipework, make all connections and test on completion, and remove waste and debris.

Page 221: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

187 Local Space Housing

620119 R TRAP:RENEW 40MM SINK OR BASIN TRAP NO 12.60 Trap:Renew ne 40mm diameter plastic trap to sink or basin

including all adjustments to pipework, make all connections and test on completion, and remove waste and debris.

620121 R TRAP:RENEW NE 40MM BATH TRAP NO 17.79 Trap:Renew ne 40mm diameter plastic trap to bath including all

adjustments to pipework, make all connections and test on completion, and remove waste and debris.

620123 R TRAP:RENEW NE 40MM SHOWER TRAP NO 87.10 Trap:Renew ne 40mm diameter plastic sealed trap to shower

including all adjustments to pipework, make all connections, remove and refix tray and test, and remove waste and debris.

620109 R WASTE:RENEW NE 40MM BEND OR CONNECTOR NO 11.48 Fitting:Renew ne 40mm diameter plastic straight connector or

bend, make all necessary joints to waste pipe and trap or stack, and test all joints on completion, and remove waste and debris.

620111 R WASTE:RENEW NE 40MM TEE NO 14.07 Fitting:Renew ne 40mm diameter plastic tee, make all necessary

joints and test on completion, and remove waste and debris.

620113 R WASTE:RENEW LEAKING JOINT NO 8.01 Waste:Renew joint of waste fitting, including remove and securely

refix and make all necessary joints, and test on completion, and remove waste and debris.

620115 R WASTE:RENEW PLASTIC PIPE CLIP NO 2.93 Waste:Renew or supply and fix pipe clip for any diameter plastic

pipe including plugging and screwing as necessary.

620131 R PIPE:RENEW 32MM WASTE LM 69.82 Pipe:Renew any pipe with 32mm plastic waste pipe complete with all

brackets, connections, bends, tees etc, cut/form holes and make good, make all necessary connections to stack, gulley or hopper head and test, and remove waste and debris.

620133 R PIPE:RENEW 40MM WASTE LM 16.80 Pipe:Renew any pipe with 40mm plastic waste pipe complete with all

brackets, connections, bends, tees etc, cut/form holes and make good, make all necessary connections to stack, gulley or hopper head and test, and remove waste and debris.

620135 R PIPE:RENEW 50MM WASTE LM 19.68 Pipe:Renew any pipe with 50mm plastic waste pipe complete with all

brackets, connections, bends, tees etc, cut/form holes and make good, make all necessary connections to stack, gulley or hopper head and test, and remove waste and debris.

Waste Pipework and Fittings - Copper 620307 U WASTE:REPAIR LEAK ON COPPER WASTE NO 11.12 Waste:Repair leaking joint(s) to any copper waste fitting including

remove and refix and all adjustments to pipework/fittings as necessary.

Page 222: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

188 Local Space Housing

Soil/Waste Pipe Blockages 620501 E STACK:CLEAR BLOCKAGE NE 2 STOREY IT 26.71 Stack:Clear blockage from soil stack ne 2 storey including gain

access remove and refix any duct covers, rod, flush out and test and remove debris from site on completion.

620503 E STACK:CLEAR BLOCKAGE 2-4 STOREY IT 39.70 Stack:Clear blockage from soil stack over 2, ne 4 storey including

gain access, remove and refix any duct covers, rod, flush out and test and remove debris from site on completion.

620505 E BATH:CLEAR BLOCKAGE TO WASTE NO 18.91 Bath:Clear blockage to waste fitting, pipe or trap, flush out and

test, remove and refix any access panels etc., as necessary, remove debris on completion and make good any finishes disturbed.

620507 E BASIN OR SINK:CLEAR BLOCKAGE NO 11.12 Basin or Sink:Clear blockage to waste fitting, pipe or trap, flush out

and test, remove and refix any access panels etc., as necessary, remove debris on completion and make good any finishes disturbed.

620509 E WASHING MACHINE:CLEAR BLOCKED WASTE NO 8.52 Washing Machine:Clear blockage to waste pipe or trap, flush out

and test, remove and refix any access panels etc., as necessary, remove debris on completion and make good any finishes disturbed.

620513 E WC PAN:CLEAR BLOCKAGE INCLUDING REMOVE NO 32.63 WC Pan:Clear blockage to WC pan including remove and refix pan

and remake all joints, flush out and test, remove and refix any access panels etc., as necessary, remove debris on completion and make good any finishes disturbed.

620515 U SHOWER:CLEAR BLOCKAGE INCLUDING REMOVE NO 21.51 Shower:Clear blockage to shower including remove/refix tray, flush

out test, remove and refix any access panels etc., as necessary, remove debris on completion and make good any finishes disturbed.

Fittings, Equipment and Appliances Associated with Services Sinks 630101 R SINK TOP:RENEW SINGLE DRAINER TOP NO 187.12 Sink Top:Renew with any size and type stainless steel single drainer

sink top complete with new taps and waste fittings, reconnect to existing supply pipework including any adjustments and provide new service valves if not already installed, complete with new plug and chain, renew plastic trap and make all connections, make good existing or provide 300mm high glazed tile splashback fixed with adhesive including all labours, silicone sealant between splashback and fitting, crossbond and test, and remove waste and debris.

Page 223: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

189 Local Space Housing

630103 R SINK TOP:RENEW DOUBLE DRAINER TOP NO 238.22 Sink Top:Renew any with size and type stainless steel double

drainer sink top complete with new taps and waste fittings, reconnect to existing supply pipework and provide new service valves if not already installed, including any adjustments, complete with new plug and chain, renew plastic trap and make all connections, make good existing or provide 300mm high glazed tile splashback fixed with adhesive including all labours, silicone sealant between splashback and fitting, crossbond and test, and remove waste and debris.

630105 R SINK UNIT:RENEW SINGLE DRAINER TOP AND BASE UNIT NO 331.41 Sink Unit:Renew with any size and type stainless steel single

drainer sink top and base unit complete with new taps and waste fittings, reconnect to existing supply pipework including any adjustments and provide new service valves if not already installed, complete with new plug and chain, renew plastic trap and make all connections, make good existing or provide 300mm high glazed tile splashback fixed with adhesive including all labours, silicone sealant between splashback and fitting, crossbond and test, and remove waste and debris.

630107 R SINK TOP:REFIX ANY LOOSE SINK TOP NO 40.26 Sink Top:Refix any type and size of loose sink top including

disconnect, remove and refix taps, pipework and fittings as necessary, remake silicone sealant joints and crossbond, and remove waste and debris.

630109 R SINK:RENEW PLUG AND CHAIN NO 5.92 Sink:Renew rubber plug and chain to sink and securely fix to and

including new stud or backplate as necessary.

630111 R SINK:RENEW NE 42MM CP WASTE NO 31.00 Sink:Renew ne 42mm cp waste fitting including disconnect trap, fix

new waste fitting, plug and chain and reconnect trap including all adjustments to pipework as necessary and test, and remove waste and debris.

630113 R SINK:RENEW NE 42MM CP COMBINED WASTE NO 41.24 Sink:Renew ne 42mm cp waste and combined overflow including

disconnect trap, fix new waste fitting, overflow, plug and chain and reconnect trap including adjustment to pipework as necessary and test, and remove waste and debris.

630115 R SINK:REFIX OR RENEW CANTILEVER BRACKETS NO 41.25 Sink:Refix or renew cantilever brackets to any size or type of

fireclay sink including disconnect and remove/refix sink if required and reconnect all pipework and all necessary plugging and making good, and remove waste and debris.

Page 224: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

190 Local Space Housing

Sinks - Deep Bowl 630117 R SINK TOP:RENEW SINGLE DRAINER DEEP BOWL TOP NO 187.12 Sink Top:Renew with any size/type stainless steel deep bowl single

drainer sink top complete with new taps and waste fittings, reconnect to existing supply pipework and provide new service valves if not already installed, including any adjustments, complete with new plug and chain, renew plastic trap, make all connections, make good existing or provide 300mm high glazed tile splashback fixed with adhesive including all labours, silicone sealant between splashback and fitting, and crossbond, test, adjust sink base unit to accommodate deep bowl and trap, and remove waste and debris.

630119 R SINK TOP:RENEW DOUBLE DRAINER DEEP BOWL TOP NO 238.22 Sink Top:Renew any with size/type stainless steel deep bowl double

drainer sink top complete with new taps and waste fittings, reconnect to existing supply pipework and provide new service valves if not already installed, including any adjustments, complete with new plug and chain, renew plastic trap, make all connections, make good existing or provide 300mm high glazed tile splashback fixed with adhesive including all labours, silicone sealant between splashback and fitting, and crossbond, test, adjust sink base unit to accommodate deep bowl and trap, and remove waste and debris.

630121 R SINK UNIT:RENEW SINGLE DRAINER DEEP TOP BASE UNIT NO 310.62 Sink Unit:Renew with any size and type stainless steel deep bowl

single drainer sink top and base unit complete with new taps and waste fittings, connect to existing supply pipework including any adjustments and provide new service valves if not already installed, complete with new plug and chain, renew plastic trap make all connections, make good existing or provide 300mm high glazed tile splashback fixed with adhesive including all labours, silicone sealant between splashback and fitting, crossbond and test, and remove waste and debris.

Sink Tops - Inset 630201 R SINK TOP:SUPPLY INSET NO 171.27 Sink Top:Supply and fix 508x935mm stainless steel inset sink top,

single bowl and single drainer complete with new taps and waste fitting, including cut out work top, sink, connect to existing supply pipework and provide new service valves if not already installed, including any adjustments, complete with new plug and chain, provide plastic waste trap and pipework, make all connections, silicone sealant between sink top and work top, crossbond and test, and remove waste and debris.

630203 R SINK TOP:RENEW INSET NO 160.88 Sink Top:Renew with 508x935mm stainless steel inset sink top,

single bowl and single drainer complete with new taps and waste fitting, reconnect to existing supply pipework, and provide new service valves if not already installed, including any adjustments, complete with new plug and chain, renew plastic waste trap, make all connections, renew silicone sealant between sink top and work top, crossbond and test, and remove waste and debris.

Page 225: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

191 Local Space Housing

Sink Tops - Deep Bowl Inset 630211 R SINK TOP:SUPPLY DEEP BOWL INSET NO 171.27 Sink Top:Supply and fix 508x935mm stainless steel inset sink top,

single deep bowl and single drainer complete with new taps and waste fitting, including cut out work top for sink, connect to existing supply pipework and provide new service valves if not already installed, including any adjustments, complete with new plug and chain, provide plastic waste trap and pipework, make all connections, silicone sealant between sink top and work top, crossbond, test, adjust sink base unit to accommodate deep bowl and trap, and remove waste and debris.

630213 R SINK TOP:RENEW WITH DEEP BOWL INSET NO 160.88 Sink Top:Renew with 508x935mm stainless steel inset sink top,

single deep bowl and single drainer complete with new taps and waste fitting, reconnect to existing supply pipework, and provide new service valves if not already installed, including any adjustments, complete with new plug and chain, renew plastic waste trap, make all connections,. renew silicone sealant between sinktop and worktop, top, crossbond, test, adjust sink base unit to accommodate deep bowl and trap, and remove waste and debris.

Sink Base Units 630301 R SINK UNIT:REMOVE SINK TOP AND RENEW 1M BASE UNIT NO 193.66 Sink Unit:Remove stainless steel sink top and set aside, renew

1000mm long sink base unit scribed and securely plugged to wall, refix and reconnect existing sink top, and provide new service valves if not already installed, renew taps, silicone sealant between splashback and fitting, and crossbond, remake connections to existing supply and waste pipework, test, and make good plaster or tiled finishes on completion, and remove waste and debris.

630303 R SINK UNIT:REMOVE SINK TOP RENEW 1.2M BASE UNIT NO 248.75 Sink Unit:Remove stainless steel sink top and set aside, renew

1200mm long sink base unit scribed and securely plugged to wall, refix and reconnect existing sink top, and provide new service valves if not already installed, renew taps, silicone sealant between splashback and fitting, and crossbond, remake connections to existing supply and waste pipework, test, and make good plaster or tiled finishes on completion, and remove waste and debris.

630305 R SINK UNIT:REMOVE SINK TOP RENEW 1.5M BASE UNIT NO 277.06 Sink Unit:Remove stainless steel sink top and set aside, renew

1500mm long sink base unit scribed and securely plugged to wall, refix and reconnect existing sink top, and provide new service valves if not already installed, renew taps, silicone sealant between splashback and fitting, and crossbond, remake connections to existing supply and waste pipework, test, and make good plaster or tiled finishes on completion, and remove waste and debris.

Page 226: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

192 Local Space Housing

WC Suites 630501 U WC SUITE:RENEW LOW LEVEL WITH PLASTIC CISTERN NO 200.61 WC Suite:Renew wc suite complete with vitreous china pan fixed

with brass or non-ferrous screws to floor including any necessary plugging, 6 litre plastic low level cistern plugged to wall, with overflow syphon, silencer pipe, float handle and ball valve, 32mm diameter flush pipe, wc cone, reconnect to existing supply and overflow pipework and provide new service valve if not already installed, make flush pipe and soil pipe joints with and including ‘Easy-Fit' connectors, and test all joints, and fix new plastic seat and lid to pan, and remove waste and debris.

630503 U WC SUITE:RENEW LOW LEVEL WITH CHINA CISTERN NO 213.57 WC Suite:Renew wc suite complete with vitreous china pan fixed

with brass or non-ferrous screws to floor including any necessary plugging, 6 litre vitreous china low level cistern plugged to wall, with overflow syphon, silencer pipe, float handle and ball valve, 32mm diameter flush pipe, wc cone, reconnect to existing supply and overflow pipework and provide new service valve if not already installed, make flush pipe and soil pipe joints with and including ‘Easy-Fit' connectors, and test all joints, and fix new plastic seat and lid to pan, and remove waste and debris.

630505 U WC SUITE:RENEW HIGH LEVEL WITH PLASTIC CISTERN NO 210.14 WC Suite:Renew wc suite complete with vitreous china pan fixed

with brass or non-ferrous screws to floor including any necessary plugging, 6 litre plastic high level cistern plugged to wall, with overflow syphon, silencer pipe, float, pull chain and ball valve, 32mm diameter flush pipe, wc cone, reconnect to existing supply and overflow pipework, and provide new service valve if not already installed, make flush pipe and soil pipe joints with and including ‘Easy-Fit' connectors, and test all joints, and fix new plastic plastic seat and lid to pan, and remove waste and debris.

630507 U WC SUITE:RENEW HIGH LEVEL WITH CHINA CISTERN NO 239.09 WC Suite:Renew wc suite complete with vitreous china pan fixed

with brass or non-ferrous screws to floor including any necessary plugging, 6 litre vitreous china high level cistern plugged to wall, with overflow syphon, silencer pipe, float, pull chain and ball valve, 32mm diameter flush pipe, wc cone, reconnect existing supply and overflow pipework, and provide new service valve if not already installed, make flush pipe and soil pipe joints with and including ‘Easy-Fit' connectors and test all joints, and fix new plastic seat and lid to pan, and remove waste and debris.

630509 U WC SUITE:RENEW CLOSE COUPLED NO 229.07 WC Suite:Renew vitreous china close coupled wc suite with pan

fixed with brass or non-ferrous screws to floor, including any necessary plugging, 6 litre vitreous china cistern plugged to wall with overflow, syphon, silencer pipe, float, handle and ball valve, reconnect to existing supply and overflow pipework, and provide new service valve if not already installed, make soil pipe joint with and including 'Easy-Fit’ connector and test all joints, fix new plastic seat and lid to pan, and remove waste and debris.

Page 227: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

193 Local Space Housing

630511 U WC PAN:RENEW COMPLETE NO 108.33 WC Pan:Renew wc pan fixed with brass or non-ferrous screws to

floor, including any plugging, renew wc cone, remake flush pipe and soil pipe joints with and including ‘Easy-Fit' connectors, fix new plastic seat and lid to pan, make good to all wall and floor finishes, and remove waste and debris.

630513 U WC PAN:RENEW SEAT COMPLETE NO 32.16 WC Pan:Renew single or double flap seat and bracket to wc pan,

and remove waste and debris.

630515 R WC PAN:REMOVE COMPLETE NO 19.21 WC Pan:Remove wc pan complete, including disconnect and seal

off, make good existing sub floor and make good to all wall and floor finishes, and remove waste and debris.

630516 R WC PAN:OVERHAUL ANY TYPE NO 42.17 WC Pan;Overhaul any type of pan, if necessary renew sea and cover, seat

hinges, refix seat, refix pan if loose, renew flush pie, renew wc cone and flush pipe joint, remake outlet or soil pipe connection with cement/sand or ‘Easy-Fit’ connector or rubber wc gasket, test for leaks on completion and leave wc pan in working order

630521 U WC PAN:RENEW FLUSH PIPE NO 13.14 WC Pan:Renew 32mm diameter low or high level flush pipe, make

joint to pan with new cone and to cistern, and remove waste and debris.

630533 R WC CISTERN:RENEW LOW LEVEL PLASTIC NO 64.53 WC Cistern:Renew with 6 litre plastic low level cistern plugged and

screwed securely to wall with overflow, syphon, silencer pipe, float, handle and ballvalve, reconnect existing supply overflow and flush pipework, and provide new service valve if not already installed, test on completion and make good all finishes, and remove waste and debris.

630535 R WC CISTERN:RENEW LOW LEVEL CHINA NO 80.08 WC Cistern:Renew with 6 litre vitreous china low level cistern

plugged and screwed securely to wall with overflow, syphon, silencer pipe, float, handle and ballvalve, reconnect existing supply overflow and flush pipework, and provide new service valve if not already installed, test on completion and make good all finishes, and remove waste and debris.

630537 R WC CISTERN:RENEW HIGH LEVEL PLASTIC NO 71.80 WC Cistern:Renew with 6 litre plastic high level level cistern on

existing brackets, with overflow, syphon, silencer pipe, float, handle and chain and ballvalve, reconnect existing supply overflow and flush pipework, and provide new service valve if not already installed, test on completion and make good all finishes, and remove waste and debris.

630539 R WC CISTERN:RENEW HIGH LEVEL CHINA NO 103.35 WC Cistern:Renew with 6 litre vitreous china high level cistern on

existing brackets, with overflow, syphon, silencer pipe, float, handle and chain and ballvalve, reconnect existing supply, overflow and flush pipework, and provide new service valve if not already installed, test on completion and make good all finishes, and remove waste and debris.

Page 228: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

194 Local Space Housing

630541 R WC CISTERN:RENEW HIGH WITH LOW PLASTIC NO 77.13 WC Cistern:Renew wc high level cistern with 6 litre plastic wc low

level cistern plugged and screwed securely to wall, with overflow, siphon, silencer pipe, float, handle and ballvalve, reconnect existing supply, overflow and flush pipework including any necessary adjustments and provide new service valve if not already installed, test on completion and make good all finishes, and remove waste and debris.

630543 R WC CISTERN:RENEW HIGH WITH LOW CHINA NO 92.68 WC Cistern:Renew wc high level cistern with 6 litre vitreous china

wc low level cistern plugged and screwed securely to wall, with overflow, syphon, silencer pipe, float, handle and ballvalve, reconnect existing supply, overflow and flush pipework including any necessary adjustments and provide new service valve if not already installed, test on completion and make good all finishes, and remove waste and debris.

630545 R WC CISTERN:REFIX INCLUDING RENEW BRACKET NO 24.83 WC Cistern:Refix any wc cistern, including turn off water supply,

disconnect and make all necessary connections to pipework and replug securely to wall, including remove existing and fix new brackets and refix cistern, turn on water supply, test and make good all finishes, and remove waste and debris.

630551 U WC CISTERN:DISCONNECT AND REMOVE NO 30.33 WC Cistern:Remove wc cistern complete including disconnect, cut

back and seal off supply and overflow pipework and make good to plasterwork and decorate to match existing, and remove waste and debris.

630559 R WC CISTERN:RENEW OVERFLOW NO 45.13 WC Cistern:Renew polypropylene overflow pipe to cistern,

disconnect, and remove existing defective overflow pipe and fit new overflow pipe, including fittings, clips, cut and make good holes and finishes as necessary, and remove waste and debris.

630571 R WC CISTERN:OVERHAUL ANY TYPE IT 21.99 WC Cistern:Overhaul any type of cistern, if necessary renew

diaphram, linkage adjustment, water level, rewasher, reseat etc, renew float, renew ballvalve, repair leak on flush pipe, tighten flush pipe nut, and check flushing operation, repair leak to overflow, including renew overflow connector, renew flushing arm and lever assembly to low level wc pull chain and handle to high level wc cistern, cistern flushing syphon and remake joints, including turn off water supply reinstate water supply and test on completion and leave cistern in working order, and remove waste and debris.

Wash Hand Basins 630701 R BASIN:RENEW ON BRACKETS COMPLETE NO 193.75 Basin:Renew vitreous china wash hand basin size ne 560x406mm

complete with brackets, new taps and waste fitting, reconnect existing supply pipework including any adjustments, provide new service valves if not already installed, complete with new plug and chain, plastic trap, connect to waste and test all joints, make good existing or fix new 300mm high glazed wall tile splashback fixed with adhesive including all labours, silicone sealant between splashback and crossbond, and remove waste and debris.

Page 229: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

195 Local Space Housing

630703 R BASIN:RENEW COMPLETE WITH PEDESTAL NO 222.81 Basin:Renew vitreous china wash hand basin size ne 560x406mm

complete with pedestal, new taps and waste fitting, reconnect existing supply pipework including any adjustments, provide new service valves if not already installed, complete with new plug and chain, plastic trap, connect to waste and test all joints, make good existing or fix new 300mm high glazed wall tile splashback fixed with adhesive including all rounded edges and labours, silicone sealant between splashback and crossbond, and remove waste and debris.

630705 R BASIN:RENEW PEDESTAL ONLY NO 78.56 Basin:Renew any vitreous china wash hand basin pedestal including

turn water off and on, remove existing wash hand basin and renew pedestal, refix basin and reconnect to supply and waste pipework, provide new service valves if not already installed, renew silicone sealant to splashback, make good all finishes and crossbond, and remove waste and debris.

630707 R BASIN:DISCONNECT AND REMOVE NO 27.73 Basin:Remove basin including brackets/pedestal complete,

disconect and seal off pipework, and remove waste and debris.

630713 R BASIN:REFIX WASH HAND BASIN NO 52.44 Basin:Refix wash hand basin, turn off water supply disconnect and

refix basin onto bracket and make all necessary connections, provide new services valves if not already installed, reinstate water supply, and test all joints, remake crossbond, and remove waste and debris.

630715 R BASIN:RENEW PLUG AND CHAIN NO 3.32 Basin:Renew rubber plug and chain to basin and secure to stud. 630717 R BASIN:RENEW CP WASTE FITTING NO 14.26 Basin:Renew 32mm chromium plated waste fitting to wash hand

basin, complete with plug and chain, bed and fix new waste and make connection to trap, and test all newly made joints on completion, and remove waste and debris.

630719 R BASIN:RENEW CP POP-UP WASTE NO 25.24 Basin:Renew 32mm chromium plated pop-up waste fitting to wash

hand basin, complete with rod cover and fixing rod, bed and fix new waste and make connection to trap, connect pop-up fitting and test all newly made joints on completion, including remove and refix pedestal as necessary.

630721 R BASIN:OVERHAUL CP POP-UP WASTE NO 19.94 Basin:Overhaul 32mm chromium plated pop-up waste fitting to

wash hand basin, including renewing rod, cover, fixing rod or connection nut, rebed as necessary, remake connection to trap, reconnect pop-up fitting and test all newly made joints on completion, including remove and refix pedestal as necessary.

Page 230: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

196 Local Space Housing

Baths 630901 R BATH:RENEW 1700MM STEEL NO 440.07 Bath:Renew upto 1700mm heavy duty vitreous enamel steel bath

complete with new taps and waste fitting, reconnect existing supply pipework including any adjustments, provide new service valves if not already installed, complete with new plug and chain, plastic trap, connect to waste pipework, 4.8mm self finished hardboard bath panels screwed with chromium plated dome headed screws to and including 38x50mm softwood framing, angle trim, make good existing or renew 300mm high glazed wall tile splashback fixed with adhesive including all labours, silicone sealant between splashback and bath, and crossbond, and remove waste and debris.

630909 R BATH:RENEW 1700MM ACRYLIC NO 451.77 Bath:Renew 8mm thick Acrylic bath upto 1700mm long complete

with new taps and waste fitting, reconnect existing supply pipework including any adjustments, provide new service valves if not already installed, complete with new plug and chain, plastic trap, connect to waste pipework, supply and fix new acrylic bath panels to match including proprietary fixings, make good existing or renew 300mm high glazed wall tile splashback fixed with adhesive including all labours, silicone sealant between splashback and bath, and crossbond, and remove waste and debris.

630917 R BATH:REMOVE AND REFIX NO 91.56 Bath:Remove and later refix any bath after access for other work

including remove/refix panels, framing, skirting, drain/refill system, disconnect and reconnect all pipework as necessary and provide new service valves if not already installed and test, renew silicone sealant, make good wall tiling and all finishes disturbed and crossbond, and remove waste and debris.

630919 R BATH:RENEW PLUG AND CHAIN NO 3.45 Bath:Renew plug and chain to bath and securely fix to stud or

overflow fitting.

630921 R BATH:RENEW 42MM CP WASTE NO 33.51 Bath:Renew 42m chromium plated waste fitting to bath complete

with plug and chain, reconnect to trap and overflow and test, remove and refix bath panel and framing and skirting etc. as required for access, and remove waste and debris.

630923 R BATH:RENEW 42MM CP WASTE OVERFLOW NO 61.69 Bath:Renew 42mm chromium plated waste and overflow fitting to

bath complete with plug and chain, including remove and securely refix bath, panel, framing, skirting etc., bed and fix new waste and overflow and make connection to trap and test, make good all finishes disturbed and renew silicone joint sealant to bath.

630931 R BATH:RENEW 42MM CP POP-UP WASTE NO 30.02 Bath:Renew 42mm chromium plated pop-up waste fitting to bath

complete with rod, cover and fixing rod, bed and fix new waste and make connection to trap, connect pop-up fitting and test all newly made joints on completion, remove and refix bath panel, framing, skirting etc. as required for access, and remove waste and debris.

Page 231: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

197 Local Space Housing

630933 R BATH:RENEW 42MM CP POP-UP WASTE OVERFLOW NO 39.97 Bath:Renew 42mm chromium plated waste and overflow fitting to

bath complete with rod, cover and fixing rod, bed and fix new waste and make connection to trap, connect pop-up fitting and test all newly made joints on completion, remove and refix bath panel, framing, skirting etc. as required for access, make good all finishes disturbed and renew silicone joint sealant to bath, and remove waste and debris.

630935 R BATH:OVERHAUL CP POP-UP WASTE NO 19.94 Bath:Overhaul 42mm chromium plated pop-up waste fitting to bath,

including renewing rod, cover, fixing rod or connection nut, rebed as necessary, remake connection to trap, reconnect pop-up fitting and test all newly made joints on completion, remove and refix bath panel, framing, skirting etc. as required for access

630925 R BATH:REGRIND AND REPOLISH NE 1800MM NO 96.60 Bath:Prepare, regrind and repolish completely any steel or cast iron

bath ne 1800mm long, including removing/refixing all fittings etc.

630927 R BATH:TOUCHUP CHIP IT 39.90 Bath:Prepare and touch up chip to any steel or cast iron bath

including removing/refixing all fittings as necessary.

630929 R BATH:RE-ENAMEL IT 85.05 Bath:Prepare, grind, re-enamel and repolish completely any steel or

cast iron bath.

Shower Trays 631101 R SHOWER TRAY:RENEW FIRECLAY COMPLETE NO 272.28 Shower Tray:Renew shower tray with ne 830x830x180mm glazed

fireclay shower tray, anti-slip finish with chromium plated waste, make necessary connections to waste pipe, seal joint between tray and wall with silicone sealant and make good all finishes, refix any shower rails, curtains or doors removed for access, and remove waste and debris.

631103 R SHOWER TRAY:RENEW ACRYLIC COMPLETE NO 232.56 Shower Tray:Renew shower tray with ne 830x830x260mm acrylic

shower tray, anti-slip finish with chromium plated waste, make necessary connections to waste pipe, seal joint between tray and wall with silicone sealant and make good all finishes, refix shower rails, curtains and doors removed for access, and remove waste and debris.

Shower Mixing Valves, Hoses and Heads 631105 R SHOWER:OVERHAUL MIXING VALVE NO 21.08 Shower:Overhaul mixing valve complete including disconnect and

remove and dismantle, repair and renew parts as necessary, reassemble, reconnect to existing pipework and test, make good all finishes, and remove waste and debris.

631107 R SHOWER:RENEW THERMOSTATIC MIXING VALVE NO 201.85 Shower:Renew any thermostatic mixing valve including disconnect

and remove existing, fix new including adjust and or extend all pipework and reconnect and test, make good all finishes, and remove waste and debris.

Page 232: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

198 Local Space Housing

631109 R SHOWER:RENEW NON-THERMOSTATIC MIX VALVE NO 118.42 Shower:Renew any non-thermostatic mixing valve including

disconnect and remove existing, fix new, adjust and or extend all pipework and reconnect and test, make good all finishes, and remove waste and debris.

631111 R SHOWER:RENEW HOSE AND SPRAY IT 28.37 Shower:Renew any shower hose and spray including remove old

and fix new and connect to mixing valve, and remove waste and debris..

631113 R SHOWER:RENEW ARM AND SPRAY HEAD IT 29.50 Shower:Renew any shower arm and spray head including

disconnect and remove old and fix new head and reconnect existing pipework, and remove waste and debris.

631115 R SHOWER:RENEW SWIVEL PATTERN HEAD IT 21.33 Shower:Renew any swivel pattern shower head including

disconnect and remove old and fix new head and reconnect existing pipework, and remove waste and debris.

631117 R SHOWER:RENEW ROSE SPRAY HEAD IT 14.47 Shower:Renew any rose spray shower head including disconnect

and remove old and fix new head and reconnect existing pipework, and remove waste and debris.

631119 R SHOWER:RENEW SHOWER KIT IT 94.25 Shower:Renew shower kit comprising slide bar, handspray and

flexible tube, disconnect and remove old and fit new kit and reconnect existing pipework, and remove waste and debris.

631121 R SHOWER:OVERHAUL SHOWER HEAD NO 7.94 Shower:Overhaul and clean out shower head including remove and

refix as necessary.

631127 R SHOWER:RENEW SHOWER SLIDE BAR IT 30.08 Shower:Renew shower slide bar, disconnect and remove old and fit new

slide bar to wall, and remove waste and debris..

Shower Rails and Curtains 631123 R SHOWER:RENEW RAILS AND CURTAINS IT 70.22 Shower:Renew any size and type of shower rail and curtain

including remove any defective rails, fix new rails with plastic plugs and matching non-ferrous screws including remove and rehang curtains, make good all finishes, and remove waste and debris.

631125 R SHOWER:RENEW CURTAIN IT 27.52 Shower:Renew any type of shower curtain to existing rails including

remove and refix rails as found expedient, and remove waste and debris.

631129 R SHOWER:RENEW RAILS IT 46.71 Shower:Renew any size and type of shower rail including remove

defective rails, fix new rails with plastic plugs and matching non-ferrous screws including remove and rehang curtains, make good all finishes, and remove waste and debris.

Page 233: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

199 Local Space Housing

Taps - Traditional Type 631301 R TAP:RENEW PAIR BASIN PILLAR TAPS IT 56.49 Tap:Renew pair 15mm chromium plated pillar taps to basin, turn

off water supply, disconnect and remove old, connect new taps, including remove and refix securely basin if required, reinstate water supply and test on completion, and remove waste and debris.

631309 R TAP:RENEW PAIR BATH PILLAR TAPS IT 71.48 Tap:Renew pair of 22mm chromium plated pillar taps to bath, turn

off water supply, remove bath panel and studding to gain access, refix on completion, reinstate water supply, test and make good, and remove waste and debris.

631313 R TAP:RENEW PAIR HIGHNECK SINK PILLAR TAPS IT 79.47 Tap:Renew pair 15mm chromium plated high neck pillar taps to

sink top, turn off water supply, remove existing pillar taps and replace with new pillar taps, reinstate water supply and test on completion, and remove waste and debris.

631319 R TAP:RENEW BRASS BIB TAP NO 43.90 Tap:Renew 15mm brass bib tap and backplate elbow securely fixed

to wall or backboard with hose union loose key head and draincock, non return valve including locate, turn off water mains supply, reinstate water supply and test on completion, and remove waste and debris.

631341 R TAP:INSTALL EXTERNAL BRASS BIB TAP NO 58.27 Tap:Install new external 15mm brass bib tap with back plate elbow

securely fixed to wall or backboard, hose union, loose key head, draincock and non return isolating valve, including locate and turn off water mains supply, extend copper service pipework to external position, lag exposed sections, all necessary builders work in connection and making good, reinstate water supply and test on completion, and remove waste and debris.

631321 R TAP:OVERHAUL ANY TYPE OF TAP NO 10.61 Tap:Overhaul any type of tap, including the dismantling and

renewal of washer, disc/o ring, reseating, repacking gland, resecure tap, cleaning down stem, reassemble, renew tap head including spindle and packing gland and test on completion, and remove waste and debris.

Taps - Ceramic Disc Type 631303 R TAP:RENEW PAIR BASIN TAPS-CERAMIC DISC IT 65.67 Tap:Renew pair 15mm chromium plated ceramic disc pillar taps to

basin, turn off water supply, disconnect and remove old, connect new taps to existing pipework including remove and refix, secure basin if required, reinstate water supply and test on completion, and remove waste and debris.

631311 R TAP:RENEW PAIR BATH TAPS-CERAMIC DISC IT 110.46 Tap:Renew pair of 22mm chromium plated ceramic disc pillar taps

to bath, turn off water supply, remove bath panel and studding for access, refix on completion, reinstate water supply, test and make good, and remove waste and debris.

Page 234: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

200 Local Space Housing

631315 R TAP:RENEW PAIR HIGHNECK SINK TAPS-CERAMIC DISC IT 90.50 Tap:Renew pair 15mm chromium plated ceramic disc high neck

pillar taps to sink top, turn off water supply, remove existing pillar taps and replace with new pillar taps and make all necessary connections to existing pipework, reinstate water supply and test on completion, and remove waste and debris.

Taps – Convert to Lever 631361 R TAPS:CONVERT BASIN TO LEVERS - PAIR IT 86.76 Taps:Convert existing pair of taps to wash hand basin to lever taps with

proprietary conversion kit including turn off water supply, remove old tap heads, connect new tap heads to existing taps, reinstate water supply, test on completion and make good, and remove waste and debris.

631363 R TAPS:CONVERT SINK TO LEVERS - PAIR IT 75.37 Taps:Convert existing pair of taps to sink to lever taps including turn off

water supply, remove old tap heads, connect new tap heads to existing taps, reinstate water supply, test on completion and make good, and remove waste and debris

631365 R TAPS:CONVERT BATH TO LEVERS - PAIR IT 107.16 Taps:Convert existing pair of taps to bath to lever taps including turn off

water supply, , remove old tap heads, connect new tap heads to existing taps, reinstate water supply, test on completion and make good, and remove waste and debris

Taps - Mixers 631335 R TAP:RENEW BATH MIXER IT 86.97 Tap:Renew mixer tap to bath, turn off water supply, remove bath

panel and studding to gain access, refix on completion, reinstate water supply, test and make good, and remove waste and debris.

631337 R TAP:RENEW BATH MIXER WITH SHOWER ATTACHMENT IT 105.62 Tap:Renew mixer tap with shower hose attachment to bath, turn

off water supply, remove bath panel and studding for access, refix on completion, reinstate water supply, test and make good, and remove waste and debris.

631339 R TAP:RENEW SINK MIXER IT 67.28 Tap:Renew mixer tap to sink top, turn off water supply, make all

necessary connections existing pipework, reinstate water supply and test on completion, and remove waste and debris.

631353 R TAP:RENEW BASIN MIXER IT 69.18 Tap:Renew mixer tap to basin, turn off water supply, make all necessary

connections existing pipework, reinstate water supply and test on completion, and remove waste and debris.

631355 R TAP:OVERHAUL ANY TYPE OF MIXER IT 36.68 Tap:Overhaul any type of mixer tap, including the dismantling and

renewal of washers, reseating, repacking gland, resecure mixer, cleaning down stems, reassemble and test on completion, turn off water remake all necessary connections existing pipework, reinstate water supply and test on completion, and remove waste and debris.

Page 235: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

201 Local Space Housing

Sealant Joints to Sanitary Appliances and Fittings 631501 R SEALANT:RENEW TO SIDES AND ENDS OF BATH IT 8.44 Sealant:Renew sanitaryware silicone sealant to side and ends of

bath providing watertight joint.

631503 R SEALANT:RENEW TO SHOWER TRAY IT 8.44 Sealant:Renew sanitaryware silicone sealant to sides of shower tray

providing watertight joint.

631505 R SEALANT:RENEW TO BASIN OR SINK IT 3.13 Sealant:Renew sanitaryware silicone sealant to sides of basin or

sink to provide watertight joint

631507 R SEALANT:APPLY TO WORKTOP AND WALL LM 3.13 Sealant:Seal joint between worktop and wall with silicone sealant. 631515 R SEALANT:PVC TRIM TO BATH IT 14.65 Sealant:Replace existing sealant to side and ends of bath with

suitable size PVCu quadrant or flexible PVC cover trim fixed to bath and tiles with sanitaryware silicone sealant to form a neat clean sealed beaded surround, including raking out existing defective sealant, cleaning and notching new quadrant trim around any obstructions.

Upstands 631701 R WORKTOP:FIT ALUMINIUM JOINT UPSTAND STRIP LM 12.14 Worktop:Provide and fix new proprietary aluminium joint strip

between worktop and wall.

631703 R WORKTOP:FIT PVC JOINT UPSTAND STRIP LM 6.76 Worktop:Provide and fix proprietary PVC joint strip between

worktop and wall.

Washing Machine Plumbing 631901 R WASHING MACHINE:FORM NEW WASTE OUTLET IT 57.78 Washing Machine:Cut in existing 40mm waste pipe and make

connection for waste from washing machine including washing machine trap and securely fixed stand pipe, and remove waste and debris.

631903 R WASHING MACHINE:SUPPLY VALVES OR STOP TAPS IT 71.20 Washing Machine:Supply and fix hot and cold water washing

machine valves including adapt and extend existing pipework ne 1m, install in line service pipe stop taps to hot and cold water supply/mains service, make all joints and test on completion, and remove waste and debris.

631905 R WASHING MACHINE:RENEW INDIVIDUAL VALVE NO 17.29 Washing Machine:Renew individual washing machine valve

including turn water off/on, drain and refill as necessary, remove existing and connect new valve existing pipework including any adaption of pipework required, make all joints and test on completion, and remove waste and debris.

Page 236: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

202 Local Space Housing

631907 R WASHING MACHINE:RENEW PAIR STOP TAPS IT 34.57 Washing Machine:Renew or supply and fix new pair of in line stop

taps including turn water off/on, drain/refill as necessary, fix new stop taps to existing pipework including any adaption of pipework required, make all joints and test on completion, and remove waste and debris.

Supply Pipework Copper Pipework - Renewals 635001 R PIPE:RENEW OR INSTALL 15MM COPPER LM 18.54 Pipe:Renew or fix new any 15mm diameter pipe with copper pipe

fixed with clips and including all made bends, connectors, fittings and any adaptors for jointing to pipes of other material, and remove waste and debris.

635003 R PIPE:RENEW OR INSTALL 22MM COPPER LM 22.54 Pipe:Renew or fix new any 22mm diameter pipe with copper pipe

fixed with clips and including all made bends, connectors, fittings and any adaptors for jointing to pipes of other material, and remove waste and debris.

635005 R PIPE:RENEW OR INSTALL 28MM COPPER LM 27.36 Pipe:Renew or fix new any 28mm diameter pipe with copper pipe

fixed with clips and including all made bends, connectors, fittings and any adaptors for jointing to pipes of other material, and remove waste and debris.

635013 R PIPE:RENEW PLASTIC CLIP TO COPPER PIPE NO 3.48 Pipe:Renew or supply and fix pipe clip for any diameter copper pipe

including plugging and screwing as necessary.

635015 R PIPE;RENEW OR PROVIDE BLANK CAP NO 5.29 Pipe;Renew or provide blank cap to upto 22mm diameter copper

pipe, including jointing to pipe, test.

Copper Pipework - Extensions 635301 R TEE:INSTALL 15MM TO EXISTING COPPER PIPEWORK NO 7.26 Tee:Cut into any existing copper service pipework and fix new

15mm tee for installation extension.

635303 R TEE:INSTALL 22MM TO EXISTING COPPER PIPEWORK NO 10.22 Tee:Cut into any existing copper service pipework and fix new

22mm tee for installation extension.

635305 R TEE:INSTALL 28MM TO EXISTING COPPER PIPEWORK NO 12.07 Tee:Cut into any existing copper service pipework and fix new

28mm tee for installation extension.

Burst Pipe Repairs 640001 E BURST:REPAIR BURST PIPE NE 28MM NO 51.74 Burst:Isolate water supply, drain down, cut out and renew ne

1.00m length of any pipe, excluding lead, ne 28mm diameter including all necessary bends, connectors, fittings, cutting and threading of pipes etc, reinstate water supply and pipe lagging and test on completion, and remove waste and debris.

Page 237: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

203 Local Space Housing

640003 E BURST:REPAIR LEAKING FITTING NE 28MM NO 36.26 Burst:Isolate water supply, drain down, remove leaking/defective

fitting of any type ne 28mm diameter, prepare existing pipework and renew fitting including any cutting and threading of pipes etc, reinstate water supply and pipe lagging and test on completion, and remove waste and debris.

640005 E BURST:REPAIR TO LEAD PIPE NO 54.04 Burst:Isolate water supply, drain down as necessary, cut out

section of existing lead pipe and insert proprietary compression couplings and length of PVC pipe to effect repair to burst pipe, reinstate water supply, relag and test, and remove waste and debris.

Pipe Insulation Moulded Foam Pipe Insulation 645007 R INSULATION:REMOVE EXTISTING FROM PIPE LM 1.04 Insulation:Remove existing insulation including securing wires

complete to any diameter pipe, and remove waste and debris.

645101 R INSULATION:RENEW UPTO 22MM PIPE LM 4.39 Insulation:Renew or supply preformed insulation to any pipe not

exceeding 22mm diameter, fix preformed split cellular insulation section to pipework with adhesive tape, and remove waste and debris.

645103 R INSULATION:RENEW TO 28MM PIPE LM 4.58 Insulation:Renew or supply preformed insulation to any pipe not

exceeding 28mm diameter, fix preformed split cellular insulation section to pipework with adhesive tape, and remove waste and debris.

Stopcocks and Valves Stopcocks 650001 R STOPCOCK:RENEW 15MM DIAMETER NO 29.65 Stopcock:Renew 15mm stopcock connected to any type of

pipework including locate supply and turn water off/on, drain down/refill, adjust pipework as necessary and test, and remove waste and debris.

650003 R STOPCOCK:RENEW 20MM DIAMETER NO 42.40 Stopcock:Renew 20mm stopcock connected to any type of

pipework including locate supply and turn water off/on, drain down/refill, adjust pipework as necessary and test, and remove waste and debris.

650005 R STOPCOCK:RENEW 22MM DIAMETER NO 34.08 Stopcock:Renew 22mm stopcock connected to any type of

pipework including locate supply and turn water off/on, drain down/refill, adjust pipework as necessary and test, and remove waste and debris.

Page 238: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

204 Local Space Housing

650007 R STOPCOCK:RENEW 25MM DIAMETER NO 53.79 Stopcock:Renew 25mm stopcock connected to any type of

pipework including locate supply and turn water off/on, drain down/refill, adjust pipework as necessary and test, and remove waste and debris.

650009 R STOPCOCK:RENEW 28MM DIAMETER NO 49.36 Stopcock:Renew 28mm stopcock connected to any type of

pipework including locate supply and turn water off/on, drain down/refill, adjust pipework as necessary and test, and remove waste and debris.

650013 R STOPCOCK:OVERHAUL ANY SIZE AND TYPE NO 21.51 Stopcock:Overhaul any size and type of stopcock including turn

water off/on, drain down/refill as required, repack, reseat stopcock, deburr spindle and test, and remove waste and debris.

Gatevalves 655001 R GATEVALVE:RENEW 15MM DIAMETER NO 29.09 Gatevalve:Renew 15mm gatevalve connected to any type of

pipework including locate supply and turn water off/on, drain down/refill, adjust pipework as necessary and test, and remove waste and debris.

655003 R GATEVALVE:RENEW 22MM DIAMETER NO 30.39 Gatevalve:Renew 22mm gatevalve connected to any type of

pipework including locate supply and turn water off/on, drain down/ refill, adjust pipework as necessary and test, and remove waste and debris.

655005 R GATEVALVE:RENEW 28MM DIAMETER NO 31.58 Gatevalve:Renew 28mm gatevalve connected to any type of

pipework including locate supply and turn water off/on, drain down/ refill, adjust pipework as necessary and test, and remove waste and debris.

655009 R GATEVALVE:OVERHAUL ANY SIZE AND TYPE NO 21.51 Gatevalve:Overhaul any size and type of gatevalve including turn

water off/on, drain down/refill as required, repack, reseat gatevalve, deburr spindle and test, and remove waste and debris.

Check and Service Valves 655101 R CHECK VALVE:RENEW OR INSTALL 15MM DIAMETER NO 57.06 Check Valve:Renew or install 15mm diameter check valve connected to

any type of pipework, locate supply, turn water off/on, drain down/refill, adjust pipework, test, and remove waste and debris.

656001 R SERVICE VALVE:RENEW OR INSTALL 15MM NO 24.78 Service Valve:Renew or install 15mm isolating or slot or screw

operated service valve connected to any type of pipework including locate supply and turn water off/on, drain down/refill, adjust pipework as necessary and test, and remove waste and debris.

656003 R SERVICE VALVE:RENEW OR INSTALL 22MM NO 25.71 Service Valve:Renew or install 22mm isolating or slot or screw

operated service valve connected to any type of pipework including locate supply and turn water off/on, drain down/refill, adjust pipework as necessary and test, and remove waste and debris.

Page 239: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

205 Local Space Housing

656005 R SERVICE VALVE:OVERHAUL ANY SIZE OR TYPE NO 20.93 Service Valve:Overhaul any size and type of service valve including

turn water off/on, drain down/refill as required, repack and test, and remove waste and debris.

Ballofix Valves 657001 R BALLOFIX VALVE:RENEW OR INSTALL 15MM NO 31.13 Ballofix Valve:Renew or install any type 15mm Ballofix valve with

and including handle connected to any type of pipework including locate supply and turn water off/on, drain down/refill, adjust pipework as necessary and test, and remove waste and debris.

657003 R BALLOFIX VALVE:RENEW OR INSTALL 22MM NO 31.91 Ballofix Valve:Renew or install any type 22mm Ballofix valve with

and including handle connected to any type of pipework including locate supply and turn water off/on, drain down/refill, adjust pipework as necessary and test, and remove waste and debris.

657005 R BALLOFIX VALVE:RENEW OR INSTALL 28MM NO 80.24 Ballofix Valve:Renew or install any type 28mm Ballofix valve with

and including handle connected to any type of pipework including locate supply and turn water off/on, drain down/refill, adjust pipework as necessary and test, and remove waste and debris.

Draincocks 660001 R DRAINCOCK:RENEW NE 19MM DRAINCOCK NO 12.06 Draincock:Renew ne 19mm copper to copper draincock on service

pipework from tank or cylinder in conjunction with associated work or whilst system drained down.

Water Storage Tanks Tanks - Cold Water Storage 665001 R TANK:RENEW WITH NE 113LTR PLASTIC IT 128.04 Tank:Renew any type of tank with ne 113 litres plastic tank, lid,

including Byelaw 30 kit, turn water off/on, drain/refill system, adjust and connect pipework, fix new insulation jacket, ballvalve and float and remove old tank, test on completion, and remove waste and debris.

665003 R TANK:RENEW WITH NE 227LTR PLASTIC IT 144.63 Tank:Renew any type of tank with over 113 and ne 227 litres

plastic tank, lid, including Byelaw 30 kit, turn water off/on, drain/refill system, adjust and connect pipework, fix new insulation jacket, ballvalve and float and remove old tank, test on completion, and remove waste and debris.

Tanks - Feed and Expansion 705001 R TANK:RENEW 18 LITRE FEED AND EXPANSION NO 149.24 Tank:Renew with 18 litre plastic feed and expansion cold water

storage tank, lid, including Byelaw 30 kit turn water off/on, drain/refill system and install corrosion inhibitor, adjust and connect pipework, fix new insulation jacket, ballvalve and float and remove old tank, test on completion, and remove waste and debris.

Page 240: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

206 Local Space Housing

Tanks - Repairs and Overhauls 665005 U TANK:RENEW 15MM BALLVALVE NO 24.25 Tank:Renew 15mm ballvalve to cold water storage tank and

transfer or renew float as necessary, and remove waste and debris.

665007 U TANK:RENEW 22MM BALLVALVE NO 33.83 Tank:Renew 22mm ballvalve to cold water storage tank and

transfer or renew float as necessary, and remove waste and debris.

665009 U TANK:RENEW 28MM BALLVALVE NO 48.24 Tank:Renew 28mm ballvalve to cold water storage tank and

transfer or renew float as necessary, and remove waste and debris.

665011 E TANK:REPAIR LEAK TO TANK OR FITTING NO 21.09 Tank:Isolate supply, drain off and repair leak to cold water tank or

copper service pipe coupling and remake joints with new fitting as necessary, reinstate water supply, refill tank and test on completion, and remove waste and debris.

665015 R TANK:DRAIN CLEAN OUT AND REFILL CWST TANK NO 20.79 Tank:Isolate supply and drain down ne 227 litre cold water storage

tank, thoroughly clean out, reinstate water supply, refill tank and test on completion, and remove waste and debris.

705003 R TANK:DRAIN CLEAN OUT AND REFILL FEED AND EXPANSION NO 36.07 Tank:Isolate supply and drain down 18 litre feed and expansion

cold water storage tank thoroughly clean out, reinstate water supply, refill tank and install corrosion inhibitor test on completion, and remove waste and debris.

665017 R TANK:REPAIR BALLVALVE AND FLOAT NO 10.54 Tank:Repair any ballvalve washer including remove ballvalve,

overhaul, renew washer and seat, refix ballvalve and or renew float if defective including turn water off/on, make good and test on completion.

665019 R TANK:RENEW 19MM OVERFLOW IT 45.05 Tank:Renew tank overflow ne 6m long in roof space with 19mm

plastic pipe and fittings including cut any holes in structure or finishes, make good and test, and remove waste and debris.

665021 R TANK:RENEW LID TO NE 18 LITRE FEED AND EXPANSION IT 17.64 Tank:Renew or provide new proprietary tank lid to feed and expansion

tank not exceeding 18 litre capacity, and remove waste and debris.

665023 R TANK:RENEW LID TO NE 113 LITRE CWST TANK IT 23.43 Tank:Renew or provide new proprietary tank lid to cold water storage

tank not exceeding 113litre capacity, and remove waste and debris.

665025 R TANK:RENEW LID TO 227 LITRE CWST TANK IT 27.78 Tank:Renew or provide new proprietary tank lid to cold water storage

tank 227litre capacity, and remove waste and debris.

Insulation – Tank 670001 R TANK:RENEW INSULATION TO NE 113 LITRE NO 12.51 Tank:Renew insulating jacket set fixed securely to cold water

storage tank, ne 113 litres, and remove waste and debris.

Page 241: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

207 Local Space Housing

670003 R TANK:RENEW INSULATION TO NE 227 LITRE NO 15.98 Tank:Renew insulating jacket set fixed securely to cold water

storage tank, over 113 and ne 227 litres, and remove waste and debris.

706001 R TANK:RENEW INSULATION TO FEED AND EXPANSION NO 9.19 Tank:Renew insulating jacket set fixed securely to 18 litre feed and

expansion cold water storage tank, and remove waste and debris.

Hot Water Cylinders Cylinders - Pre-Insulated Direct 675001 U CYLINDER:RENEW DIRECT INSULATED NEW HEATER NO 374.73 Cylinder:Isolate supply, drain down, disconnect, clear away and

renew with ne 144 litre direct copper pre-insulated cylinder, connect existing pipes, refill, vent and test system, including all newly made joints, install 3 kilowatt top entry immersion heater and thermostat, remake all bonding, remove/refix shelves etc., reconnect electricity supply and test on completion, and remove waste and debris.

675003 U CYLINDER:RENEW DIRECT INSULATED REFIX HEATER NO 358.79 Cylinder:Isolate supply, drain down, disconnect, clear away and

renew with ne 144 litre direct copper pre-insulated cylinder, connect existing pipes, refill, vent and test system, including all newly made joints, transfer and refix immersion, heater and thermostat, remake all bonding, remove/refix shelves etc., reconnect electricity supply and test on completion, and remove waste and debris.

Cylinders - Insulating Jacket Direct 675009 U CYLINDER:RENEW DIRECT JACKET NEW HEATER NO 359.76 Cylinder:Isolate supply, drain down, disconnect, clear away and

renew with ne 144 litre direct copper cylinder, connect existing pipes, refill vent and test system, including all newly made joints, fix new insulating jacket, install 3kW top entry immersion heater and thermostat, remake all bonding, remove and refix all shelves etc. reconnect electricity supply and test on completion, and remove waste and debris.

675011 U CYLINDER:RENEW DIRECT JACKET REFIX HEATER NO 343.82 Cylinder:Isolate supply, drain down, disconnect immersion heater

and set aside, disconnect, clear away and renew with ne 144 litre direct copper cylinder, connect existing pipes, refill, refix immersion heater, vent and test system, including all newly made joints, fix new insulating jacket, remake all bonding, remove and refix any shelves etc. reconnect electricity supply and test on completion, and remove waste and debris.

Cylinders - Pre-Insulated Indirect 675005 U CYLINDER:RENEW INDIRECT INSULATED NEW HEATER NO 312.22 Cylinder:Isolate supply, drain down, disconnect, clear away and

renew with ne 140 litre indirect pre-insulated cylinder, connect existing pipes, refill, vent and test system, including all newly made joints, install 3 kilowatt top entry immersion heater and thermostat, remake all bonding, remove and refix shelves, reconnect electricity supply and test on completion, and remove waste and debris.

Page 242: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

208 Local Space Housing

675007 U CYLINDER:RENEW INDIRECT INSULATED REFIX HEATER NO 296.28 Cylinder:Isolate supply, drain down, disconnect, clear away and

renew with ne 140 litre indirect pre-insulated cylinder, connect existing pipes, refill, vent and test system, including all newly made joints, transfer and refix existing immersion heater and thermostat, remake all bonding, remove and refix shelves, reconnect electricity supply and test on completion, and remove waste and debris.

Cylinders - Jacket Indirect 675013 U CYLINDER:RENEW INDIRECT JACKET NEW HEATER NO 304.03 Cylinder:Isolate supply, drain down, disconnect, clear away and

renew with ne 140 litre indirect copper cylinder, connect existing pipes, refill vent and test, including all newly made joints, fix new insulating jacket, install 3 kilowatt top entry immersion heater and thermostat, remake all bonding, remove/refix shelves etc., reconnect electricity supply and test on completion, and remove waste and debris.

675015 U CYLINDER:RENEW INDIRECT JACKET REFIX HEATER NO 288.09 Cylinder:Isolate supply, drain down, disconnect immersion heater

and set aside, disconnect, clear away and renew with ne 140 litre indirect copper cylinder, connect existing pipes, refill, refix immersion heater, vent and test system, including all newly made joints, fix new insulating jacket, remake all bonding, remove and refix any shelves etc. reconnect electricity supply and test on completion, and remove waste and debris.

Cylinders - Jacket Primatic 675017 U CYLINDER:RENEW PRIMATIC JACKET NEW HEATER NO 542.13 Cylinder:Isolate supply, drain down, disconnect, clear away and

renew with 117 litre primatic copper cylinder, connect existing pipes, refill vent and test, including all newly made joints, fix new insulating jacket, install 3 kilowatt top entry immersion heater and thermostat, remake all bonding, remove and refix shelves etc., reconnect electricity supply and test on completion, and remove waste and debris.

675019 U CYLINDER:RENEW PRIMATIC JACKET REFIX HEATER NO 526.19 Cylinder:Isolate supply, drain down, disconnect, clear away and

renew with 117 litre primatic copper cylinder, connect existing pipes, refill, vent and test system including all newly made joints, transfer and refix immersion heater, fix new insulating jacket, remake all bonding, reconnect electricity, remove and refix shelves etc., and test on completion, and remove waste and debris.

Cylinders - Pre-Insulated Fortic Direct 675021 U CYLINDER:RENEW FORTIC DIRECT NEW HEATER NO 484.93 Cylinder:Isolate supply, drain down, disconnect, clear away and

renew with ne 115 litre 'Fortic' direct pre-insulated combination tank, connect to existing pipes, vent and test system, including all newly made joints, install 3kW immersion heater and thermostat, remake all bonding, remove and refix all shelves etc. reconnect electricity supply and test on completion, and remove waste and debris.

Page 243: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

209 Local Space Housing

675023 U CYLINDER:RENEW FORTIC DIRECT REFIX HEATER NO 467.54 Cylinder:Isolate supply, drain down, disconnect immersion heater

and set aside, disconnect, clear away and renew with ne 115 litre 'Fortic' direct pre-insulated combination tank, connect to existing pipes, refill, transfer and refix immersion heater, vent and test system including all newly made joints, remake all bonding, remove and refix any shelves etc. reconnect electricity supply and test on completion, and remove waste and debris.

Cylinders - PreInsulated Fortic Indirect 675025 U CYLINDER:RENEW FORTIC INDIRECT NEW HEATER NO 507.84 Cylinder:Isolate supply, drain down, disconnect, clear away and

renew with ne 115 litre 'Fortic' indirect pre-insulated combination tank, connect existing pipes, refill, vent and test, including made joints, install 3kW immersion heater and thermostat, remake all bonding, remove and refix shelves etc., reconnect electricity supply and test on completion, and remove waste and debris.

675027 U CYLINDER:RENEW FORTIC INDIRECT REFIX HEATER NO 491.90 Cylinder:Isolate supply, drain down, disconnect immersion heater

and set aside, disconnect, clear away and renew with ne 115 litre 'Fortic' litre indirect pre-insulated combination tank, connect to existing pipes, refill, refix immersion heater, vent and test system including all newly made joints, remake all bonding, remove and refix any shelves etc, reconnect electricity supply and test on completion, and remove waste and debris.

Cylinders - Economy 7 Type 675029 U CYLINDER:RENEW ECONOMY 7 NEW HEATERS NO 446.38 Cylinder:Isolate supply, drain down, disconnect, clear away and

renew with Economy 7 hot water cylinder, connect existing pipes, refill vent and test system, including all newly made joints, install new top and bottom entry immersion heaters and thermostats, remake all bonding, remove and refix all shelves etc. reconnect electricity supply and test on completion, and remove waste and debris.

675031 U CYLINDER:RENEW ECONOMY 7 REFIX HEATERS NO 415.34 Cylinder:Isolate supply, drain down, disconnect, clear away and

renew with Economy 7 hot water cylinder, connect existing pipes, refill vent and test system, including all newly made joints, transfer and refix top and bottom entry immersion heaters and thermostats, remake all bonding, remove and refix all shelves etc., reconnect electricity supply and test on completion, and remove waste and debris.

Cylinders - Elson Type Combination Tanks 675033 U CYLINDER:RENEW ELSON TANK NEW HEATERS NO 1100.52 Cylinder:Isolate supply, drain down, disconnect, clear away and

renew with ne 144 litre 'Elson' combination tank, connect existing pipes, vent and test system, including all newly made joints, install new top and bottom entry immersion heaters and thermostats, remake all bonding, remove and refix all shelves etc, reconnect electricity supply and test on completion, and remove waste and debris.

Page 244: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

210 Local Space Housing

675035 U CYLINDER:RENEW ELSON TANK REFIX HEATERS NO 1069.49 Cylinder:Isolate supply, drain down, disconnect, clear away and

renew with ne 144 litre 'Elson' combination tank, connect existing pipes vent and test system, including all newly made joints, transfer and refix topand bottom entry immersion heaters and thermostats, remake all bonding, remove and refix all shelves etc, reconnect electricity supply and test on completion, and remove waste and debris.

Cylinders - Repairs etc 675037 U CYLINDER:RENEW LEAKING FITTING NO 13.29 Cylinder:Renew or remake leaking joint to fitting to copper cylinder

and test upon completion, and remove waste and debris.

675039 U CYLINDER:REPAIR LEAK NO 35.44 Cylinder:Drain down copper cylinder as necessary, remove jacket,

shelves etc., prepare and wipe patch to repair leak, refill, vent and test system, including all newly made joints, refix jacket, and test on completion, and remove waste and debris.

675041 R CYLINDER:DRAIN DESCALE FLUSH OUT NO 54.86 Cylinder:Isolate electricity supply, drain down cylinder, remove

jacket, shelves etc., remove, descale, flush out and securely refix cylinder, refill, vent and test system, including all newly made joints, reconnect electricity supply, refix jacket and test on completion, and remove waste and debris.

675043 U CYLINDER:RENEW FLANGE NO 55.57 Cylinder:Isolate supply, drain down copper cylinder, remove jacket,

shelves etc., disconnect, clear away and renew immersion heater flange, refix jacket, shelves etc., refill, vent and test system, and remove waste and debris.

675045 R CYLINDER:SUPPLY PAIR ISOLATING VALVES IT 58.69 Cylinder:Isolate supply, drain down as necessary and insert pair of

isolating valves to hot water cylinder circuit, reinstate supply, fill, vent and test, and remove waste and debris.

675047 R CYLINDER:SERVICE PRESSURISED CYLINDER NO 31.18 Cylinder:Carry out service to any size/type of pressurised hot water

cylinder.

675049 U CYLINDER:RENEW JACKET NO 15.68 Cylinder:Renew insulating jacket set fixed securely to cylinder, and

remove waste and debris.

Page 245: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

211 Local Space Housing

Proprietary Prefabricated Hot/Cold Plumbing Units 677001 R PLUMBUNIT:RENEW STD DIR 227LTR COLD NE 144LTR HOT NO 607.31 Plumbunit:Renew any size or type proprietary prefabricated

plumbing unit with new unit comprising ne 227 ltr polythene cold water storage tank with lid, ballvalve, Bylaw 30 kit, ne 144 ltr direct pre-insulated copper grade 3 cylinder, two 3 kilowatt top/bottom entry immersion heaters and thermostats, copper pipework, fittings, connections and valves all pre-plumbed on vented baseboards within painted steel supporting bases and framework, including turn water supply on/off, drain down, disconnect, clear away, connect to existing supply/distribution and overflow pipes etc, adjust ballvalve and float, refill, vent and test system, including all newly made joints, remake all earth bonding, reconnect electricity supply and test on completion, and remove waste and debris.

677003 R PLUMBUNIT:RENEW STD DIR 227LTR COLD NE 210LTR HOT NO 761.27 Plumbunit:Renew any size or type proprietary prefabricated

plumbing unit with new unit comprising ne 227 ltr polythene cold water storage tank with lid, ballvalve, Bylaw 30 kit, over 144 ltr but ne 210 ltr direct pre-insulated copper grade 3 cylinder, two 3 kilowatt top/bottom entry immersion heaters and thermostats, copper pipework, fittings, connections and valves all pre-plumbed on vented baseboards within painted steel supporting bases and framework, including turn water supply on/off, drain down, disconnect, clear away, connect to existing supply/distribution and overflow pipes etc, adjust ballvalve and float, refill, vent and test system, including all newly made joints, remake all earth bonding, reconnect electricity supply and test on completion, and remove waste and debris.

677011 R PLUMBUNIT:RENEW STD IND 227LTR COLD NE 140LTR HOT NO 770.76 Plumbunit:Renew any size or type proprietary prefabricated

plumbing unit with new unit comprising ne 227 ltr polythene cold water storage tank and ne 18 ltr feed and expansion tank with lids, ballvalves, Bylaw 30 kits, ne 140 ltr indirect pre-insulated copper grade 3 cylinder, copper pipework, fittings, connections and valves all pre-plumbed on vented baseboards within painted steel supporting bases and framework, including turn water supply on/off, drain down, disconnect, clear away, connect to existing supply/distribution and overflow pipes etc, adjust ballvalve and float, refill, vent, balance and test systems, including all newly made joints, remake all earth bonding, reconnect electricity supply and test on completion, and remove waste and debris.

677013 R PLUMBUNIT:RENEW STD IND 227LTR COLD NE 162LTR HOT NO 788.88 Plumbunit:Renew any size or type proprietary prefabricated

plumbing unit with new unit comprising ne 227 ltr polythene cold water storage tank and ne 18 ltr feed and expansion tank with lids, ballvalves, Bylaw 30 kits, over 140 ltr but ne 162 ltr indirect pre-insulated copper grade 3 cylinder, copper pipework, fittings, connections and valves all pre-plumbed on vented baseboards within painted steel supporting bases and framework, including turn water supply on/off, drain down, disconnect, clear away, connect to existing supply/distribution and overflow pipes etc, adjust ballvalve and float, refill, vent, balance and test systems, including all newly made joints, remake all earth bonding, reconnect electricity supply and test on completion, and remove waste and debris.

Page 246: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

212 Local Space Housing

677021 R PLUMBUNIT:ADAPTATION FOR SHOWER BOOSTER PUMP NO 483.99 Plumbunit:Extra over new proprietary prefabricated plumbing unit

any type or size for shower booster pump factory fitted.

677023 R PLUMBUNIT:ADAPTATION FOR HEATING CONTROLS NO 192.63 Plumbunit:Extra over new proprietary prefabricated plumbing unit

any type or size with indirect cylinder for central heating controls including wiring centre, timer/programmer, cylinder sensor, three port valve, actuator, circulating pump, cabling etc. all factory fitted.

677025 R PLUMBUNIT:ADAPTATION FOR SEALED HEATING SYSTEM NO 177.89 Plumbunit:Extra over new proprietary prefabricated plumbing unit

any type or size with indirect cylinder for adaptation to sealed central heating system comprising ne 12 ltr expansion vessel in lieu of feed and expansion tank and including filling loop, pressure gauge, expansion valve etc. all factory fitted.

Scale Reducers 680001 R SCALE REDUCER:SUPPLY MAGNETIC TYPE IT 61.81 Scale Reducer:Supply and install magnetic type scale reducer to

cold water supply including locate and turn water off, drain down as necessary, cut into existing pipe and insert scale reducer unit including all necessary connections, reinstate water supply and test, and remove waste and debris.

680003 R SCALE REDUCER:SUPPLY ELECTROLYTIC TYPE IT 89.46 Scale Reducer:Supply and install electrolytic type scale reducer to

cold water supply including locate and turn water off, drain down as necessary, cut into existing pipe and insert scale reducer unit including all necessary connections, reinstate water supply and test, and remove waste and debris.

680005 R SCALE REDUCER:SUPPLY CHEMICAL TYPE IT 130.04 Scale Reducer:Supply and install chemical in line scale reducer to

cold water supply including locate and turn water off, drain down as necessary, cut into existing pipe and insert scale reducer unit including fix two stop valves, make all necessary connections and test, and remove waste and debris.

680007 R SCALE REDUCER:RECHARGE CHEMICAL TYPE IT 32.83 Scale Reducer:Gain access and recharge any type of chemical scale

reducer.

680009 R SCALE REDUCER:ELECTRO MAGNETIC NON INTRUSIVE TYPE IT 126.45 Scale Reducer:Supply and install electronic ‘Water King’ non

intrusive type scale reducer to hot or cold water pipes complete, computerised control unit with internal transformer hardwired to fused electrical outlet, wire aerials coiled around pipework and secured, make all necessary connections and test, and remove waste and debris.

Page 247: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

213 Local Space Housing

Sundry Works Airlocks 685001 U WATER HAMMER:CLEAR AND REMEDY AIRLOCK IT 31.18 Water Hammer:Clear water hammer in water system, check

ballvalve and taps, including turn water supply off, drain as necessary reinstate water supply and test on completion, report to Client Representative.

Safety Checks and Drain Downs 690001 X VOID:DRAIN DOWN HOT AND COLD WATER IT 20.79 Void:Drain down hot and cold domestic water system to void

property.

690003 X VOID:REFILL HOT AND COLD WATER IT 46.77 Void:Refill hot and cold domestic water system to void property and

check incoming water supply.

690005 X VOID:SAFETY CHECK HOT AND COLD WATER IT 23.39 Void:Carry out safety check of complete hot and cold water

plumbing and waste installation to any void property and provide written report to the Client Representative.

Duct Covers and Frames 695001 R PANEL:REMOVE AND REFIX FOR CLIENTR INSPECTIONS NO 5.61 Panel:Remove all panels and duct covers for access to concealed

sanitary fittings and pipework to determine and carry out repairs and renewals and later securely refix on completion (generally deemed included within schedule items - only allowable on the specific instruction of the Client Representative).

Bathroom Ancillaries 696001 R TOILET ROLL HOLDER:RENEW CHROMIUM PLATED NO 25.64 Toilet Roll Holder:Renew or supply and fix new chromium plated

toilet roll holder securely fixed to structure including plugging as necessary.

696003 R TOILET ROLL HOLDER:RENEW PLASTIC NO 15.14 Toilet Roll Holder:Renew or supply and fix new plastic toilet roll

holder securely fixed to structure including plugging as necessary.

696005 R TOWEL RAIL:RENEW NO 42.71 Towel Rail:Renew or supply and fix new chromium plated towel rail

610mm long securely fixed to structure including plugging as necessary.

696007 R TOWEL HOLDER:RENEW NO 36.05 Towel Holder:Renew or supply and fix new chromium plated two

arm towel holder securely fixed to structure including plugging as necessary.

696009 R SOAP DISH:RENEW NO 18.90 Soap Dish:Renew or supply and fix new chromium plated soap dish,

with concealed fixing, securely fixed to structure including plugging as necessary.

Page 248: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

214 Local Space Housing

696011 R TOOTHBRUSH/TUMBLER HOLDER:RENEW NO 20.77 Toothbrush/Tumbler Holder:Renew or supply and fix new chromium

plated toothbrush and tumbler holder with concealed fixing, securely fixed to structure including plugging as necessary.

696013 R DRYER:RENEW INTERNAL TIDYDRY NO 62.09 Dryer:Renew or supply and install ‘Tidydry’ or other equal and

approved 5 line internal clothes dryer and hook, both plugged and screwed to any background and make good all finishes.

696015 R DRYER:REFIX INTERNAL TIDYDRY NO 9.33 Dryer:Refix ‘Tidydry’ or similar 5 line internal clothes dryer and

hook to any background and make good all finishes.

696017 R BATHROOM CABINET:RENEW NO 50.05 Bathroom Cabinet:Renew or supply and fix new lockable double

bathroom/first aid cabinet of any type complete with shelves and two keys, remove existing defective unit and clear away if necessary, fix cabinet securely to structure including plugging, screwing and making good as necessary.

696021 R GLASS SHELF:RENEW NO 11.09 Glass Shelf:Renew or supply and install new bathroom glass shelf

ne 600mm long x 127mm wide existing brackets.

696022 R GLASS SHELF:RENEW INCLUDING BRACKETS NO 37.33 Glass Shelf:Renew or supply and fix new bathroom glass shelf ne

600mm long x 127mm wide complete with chromium plated glass shelf brackets, brackets securely fixed to structure including plugging as necessary.

696023 R GLASS SHELF BRACKET:RENEW NO 16.84 Glass Shelf Bracket:Renew chromium plated glass shelf bracket,

including remove, set aside and refix shelf as necessary, bracket securely fixed to structure including plugging as necessary.

696025 R BATHROOM:REFIX ANCILLARY NO 7.73 Bathroom:Securely refix any ancillary fitting, toilet roll holder, towel

holder, soap dish, shelf, cabinet etc, having up to 4 No. screws, to structure of any background including plugging, screwing and making good as necessary.

Fire Fighting Equipment 698001 U FIRE EXTINGUISHER:RENEW 9LTR WATER IT 66.74 FireExtinguisher:Renew or supply and fix 9 litre water fire

extinguisher (fire rating 13A) Class A fires, including supply and fix bracket fixed to any background, and dispose of existing extinguisher to approved disposal site.

698003 U FIRE EXTINGUISHER:RENEW 9LTR FOAM IT 100.54 FireExtinguisher:Renew or supply and fix 9 litre foam fire

extinguisher (fire rating 13A) Class A and B fires, including supply and fix bracket fixed to any background, and dispose of existing extinguisher to approved disposal site.

698005 U FIRE EXTINGUISHER:RENEW DRY POWDER 1KG IT 44.20 Fire Extinguisher:Renew or supply and fix 1kg capacity 12gm CO2

cartridge, Class A, B and C fires (fire rating 5A:34B) including supply and fix bracket fixed to any background, and dispose of existing extinguisher to approved disposal site.

Page 249: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

215 Local Space Housing

698007 U FIRE EXTINGUISHER:RENEW DRY POWDER 2KG IT 59.36 Fire Extinguisher:Renew or supply and fix 2kg capacity 28gm CO2

cartridge, Class A, B and C fires (fire rating 5A:34B) including supply and fix bracket fixed to any background, and dispose of existing extinguisher to approved disposal site.

698009 U FIRE EXTINGUISHER:RENEW CARBON DIOXIDE IT 89.45 Fire Extinguisher:Renew or supply and fix 2kg capacity CO2 type

with horn and hose, Class B fires (fire rating 34B) including supply and fix bracket fixed to any background, and dispose of existing extinguisher to approved disposal site.

698011 U FIRE BLANKET:RENEW OR SUPPLY IT 30.93 Fire Blanket:Renew or supply and fix 1100x1100mm glassfibre

blanket in GRP container, including fixing to any background and dispose of existing blanket to approved disposal site.

Underground Water Mains Water Mains - Alkathene Pipework 043101 R MAIN:LAY 19MM ALKATHENE NE1M DEEP LM 98.79 Main:Excavate ne 1.00m deep, compact bottoms, lay 150mm thick

gravel bed and haunch, lay 19mm diameter alkathene pipe including all fittings backfill and remove waste and debris..

043103 R MAIN:LAY 19MM ALKATHENE 1-2M DEEP LM 166.24 Main:Excavate over 1.00m not exceeding 2.00m deep, compact

bottoms, lay 150mm thick gravel bed and haunch, lay 19mm diameter alkathene pipe including all fittings, backfill and remove waste and debris.

Burst Water Mains - Copper Pipework 043301 E MAIN:REPAIR UNDERGROUND BURST NO 100.68 Main:Isolate water supply, drain down, cut out and renew length of

15mm diameter copper underground main not exceeding 1.00m long in trench, with straight connectors, including all necessary bends and fittings, wrapping with tape and reinstate water supply and test on completion, item allows for all excavation, earthwork support and subsequent backfill and remove waste and debris, reinstate topsoil and any turf.

Burst Water Mains - Alkathene Pipework 043503 E BURST:EXCAVATE AND REPAIR BURST NE 28 MM NO 111.73 Burst:Isolate water supply, drain down, cut out and renew length of

UPTO 28mm diameter alkathene pipe, not exceeding 1.00m long with straight couplings, including all necessary fittings, reinstate water supply and test all newly made joints on completion, item allows for all excavation, earthwork support, backfill and remove waste and debris.

External Stopcocks 045001 U STOPCOCK:RENEW EXTERNAL BOX AND PIPE NO 82.59 Stopcock:Renew stopcock box and salt glazed pipe ne 750mm deep

including all necessary excavation and backfill and make good to existing finishes, and remove waste and debris.

Page 250: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

216 Local Space Housing

045003 U STOPCOCK:RENEW EXTERNAL BOX NO 19.43 Stopcock:Renew stopcock box including remove existing and bed

new in cement mortar (1:3) and make good existing finishes, and remove waste and debris.

045007 U STOPCOCK:RENEW COPPER TO COPPER NE 22MM NO 28.21 Stopcock:Renew copper to copper mains stopcock ne 22mm

diameter including turn water off/on, fix new stopcock including all couplings and connections and test, and remove waste and debris.

Client Inspections - Plumbing 697001 E CLIENT INSPECTION:PLUMBING IT 15.59 Client Inspection:Undertake client inspection and testing etc and

report to Client Representative (any repairs required to be ordered must be instructed by Client Representative).

Page 251: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

217 Local Space Housing

HEATING, GAS APPLIANCES AND INSTALLATIONS Heating Pumps and Valves Pumps 702001 U PUMP:RENEW WHERE ISOLATING VALVES FITTED NO 93.05 Pump:Shut off isolating valves and renew variable head type

circulating pump, make all necessary connections to pipework and electrical supply and test on completion, and remove waste and debris.

702003 U PUMP:RENEW INCLUDING SUPPLY ISOLATING VALVES NO 164.87 Pump:Shut down supply, drain down as necessary and remove

existing pump, supply and fix new variable head type circulating pump and pair of isolating valves and connect to existing pipework and electrical supply including all adjustments, refill system, install corrosion inhibitor and test, and remove waste and debris.

702005 U PUMP:SUPPLY NEW INCLUDING ISOLATING VALVES NO 177.10 Pump:Turn off water, drain down cut into pipework supply and

connect new variable head type circulating pump to pipework and electrical supply install pair of isolating valves, reinstate water supply, install install corrosion inhibitor and test on completion, and remove waste and debris.

702007 R PUMP:SERVICE AND OVERHAUL NO 36.21 Pump:Shut off valves and drain down, disconnect and remove

pump, service and overhaul, clean impellor, reconnect pump to pipework and electrical supply, reinstate water supply, and install corrosion inhibitor and test on completion

702009 U PUMP:RENEW SINGLE PUMP VALVE NO 50.70 Pump:Locate and drain down system, disconnect, clear away and

renew copper to copper central heating pump valve, reinstate supply, install corrosion inhibitor and test on completion, and remove waste and debris.

702010 U PUMP:RENEW PAIR OF PUMP VALVES NO 91.22 Pump:Locate and drain down system, disconnect, clear away and

renew pair of copper to copper central heating isolating pump valves, reinstate supply, install corrosion inhibitor and test on completion, and remove waste and debris.

Motorised and Zone Valves Renewals 702501 U MOTORISED VALVE:RENEW 22MM NO 97.21 Motorised Valve:Shut off valves and drain down, disconnect and

renew upto 22mm three port motorised valve complete including make all necessary connections to existing pipework and electrical supply and subsequently refill, install corrosion inhibitor and test on completion, and remove waste and debris.

Page 252: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

218 Local Space Housing

702502 U MOTORISED VALVE:RENEW 28MM NO 114.50 Motorised Valve:Shut off valves and drain down, disconnect and

renew upto 28mm three port motorised valve complete including make all necessary connections to existing pipework and electrical supply and subsequently refill, install corrosion inhibitor and test on completion, and remove waste and debris.

702506 U MOTORISED VALVE:RENEW NE 28MM ACTIVATOR NO 49.74 Motorised Valve:Renew electric motor activator to any motorised or

zone valve ne 28mm and test on completion, and remove waste and debris.

702511 U ZONE VALVE:RENEW 22MM NO 91.75 Zone Valve:Shut off valves and drain down, disconnect and renew

upto 22mm two way zone valve complete including make all necessary connections to existing pipework and electrical supply and subsequently refill, install corrosion inhibitor and test on completion, and remove waste and debris.

702512 U ZONE VALVE:RENEW 28MM NO 110.48 Zone Valve:Shut off valves and drain down, disconnect and renew

28mm two way zone valve complete including make all necessary connections to existing pipework and electrical supply and subsequently refill, install corrosion inhibitor and test on completion, and remove waste and debris.

Radiators Radiators – Repairs 703001 U RADIATOR:VENT RADIATORS IT 28.75 Radiator:Vent all radiators to any property and balance system. 703003 U RADIATOR:DRAIN DOWN AND REFILL SYSTEM IT 79.19 Radiator:Drain down, reinstate water supply and refill complete

system, install corrosion inhibitor, including venting radiators, balance and test system and remove waste and debris.

703005 U RADIATOR:MAKE GOOD CONNECTION NO 27.59 Radiator:Drain down radiator, make good faulty connection to

valve, flush out, reinstate water supply, and refill, install corrosion inhibitor including venting and test, and remove waste and debris.

703007 R RADIATOR:REMOVE AND REFIX VALVELESS IT 89.07 Radiator:Remove and refit valveless radiator including drain and

refill system, disconnect, remove, refix loose bracket(s), reconnect including providing and fixing one pair of radiator valves and all necessary adjustments to pipework, install corrosion inhibitor, vent and test, and remove waste and debris.

703009 R RADIATOR:REMOVE AND REFIX IT 27.66 Radiator:Remove and refix radiator including shut off valves, drain

radiator, disconnect, remove, refix loose bracket(s), refix and reconnect to valves, install corrosion inhibitor, vent and test, and remove waste and debris.

Page 253: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

219 Local Space Housing

703011 U RADIATOR:TEST AND BALANCE SYSTEM IT 69.43 Radiator:Fire up boiler, adjust controls to correct setting, vent

radiators, test feed and expansion tank, cylinder and rectify minor leaks, complete heat test, balance out system, and test.

703013 R RADIATOR:RENEW AND REFIX BRACKET NO 19.01 Radiator:Renew/refix existing radiator bracket fixed to wall and

remove waste and debris.

703015 U RADIATOR:CLEAN AND FLUSH OUT SINGLE NO 33.19 Radiator:Clean and flush out any size radiator, isolate supplies,

drain down, remove to outside property, clean and flush out, refix radiator, refill, vent and test, and remove waste and debris.

Radiator - Single Panel Renewals 703017 R RADIATOR:RENEW SINGLE PANEL NE 600X600 IT 72.68 Radiator:Shut off valves and drain down, remove and renew with

single panel radiator and brackets ready primed ne 600x600mm, make all necessary connections to existing valves, reinstate water supply, refill, install corrosion inhibitor, vent and test, and remove waste and debris.

703019 R RADIATOR:RENEW SINGLE PANEL NE 1200X600 IT 104.41 Radiator:Shut off valves and drain down, remove and renew with

single panel radiator and brackets ready primed ne 1200x600mm, make all necessary connections to existing valves, reinstate water supply, refill, install corrosion inhibitor, vent and test, and remove waste and debris.

703021 R RADIATOR:RENEW SINGLE PANEL NE 1800X600 IT 158.04 Radiator:Shut off valves and drain down, remove and renew with

single panel radiator and brackets ready primed ne 1800x600mm, make all necessary connections to existing valves, reinstate water supply, refill, install corrosion inhibitor, vent and test, and remove waste and debris.

703023 R RADIATOR:RENEW SINGLE PANEL OVER 1800X600 IT 218.04 Radiator:Shut off valves and drain down, remove and renew with

single panel radiator and brackets ready primed over 1800x600mm, make all necessary connections to existing valves, reinstate water supply, refill, install corrosion inhibitor, vent and test, and remove waste and debris.

Radiators - Single Convector Renewal 703025 R RADIATOR:RENEW SINGLE CONVECTOR NE 600X600 IT 70.98 Radiator:Shut off valves and drain down, remove and renew with

single panel convector radiator and brackets, ready primed, ne 600x600mm, make all connections to existing valves, reinstate water supply, refill, install corrosion inhibitor, vent and test, and remove waste and debris.

703027 R RADIATOR:RENEW SINGLE CONVECTOR NE 1200X600 IT 98.66 Radiator:Shut off valves and drain down, remove and renew with

single panel convector radiator and brackets, ready primed ne 1200x600mm, make all connections to existing valves, reinstate water supply, refill, install corrosion inhibitor, vent and test, and remove waste and debris.

Page 254: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

220 Local Space Housing

703029 R RADIATOR:RENEW SINGLE CONVECTOR NE 1800X600 IT 155.32 Radiator:Shut off valves and drain down, remove and renew with

single panel convector radiator and brackets, ready primed, ne 1800x600mm, make all connections to existing valves, reinstate water supply, refill, install corrosion inhibitor, vent and test, and remove waste and debris.

703031 R RADIATOR:RENEW SINGLE CONVECTOR OVER 1800X600 IT 270.23 Radiator:Shut off valves and drain down, remove and renew with

single panel convector radiator and brackets, ready primed, over 1800x600mm, make all connections to existing valves, reinstate water supply, refill, install corrosion inhibitor, vent and test, and remove waste and debris.

Radiators - Double Convector Renewals 703033 R RADIATOR:RENEW DOUBLE CONVECTOR NE 600X600 IT 93.44 Radiator:Shut off valves and drain down, remove and renew with

double panel convector radiator and brackets, ready primed, ne 600x600mm, make all connections to existing valves, reinstate water supply, refill, install corrosion inhibitor, vent and test, and remove waste and debris.

703035 R RADIATOR:RENEW DOUBLE CONVECTOR NE 1200X600 IT 144.61 Radiator:Shut off valves and drain down, remove and renew with

double panel convector radiator and brackets, ready primed, ne 1200x600mm, make all connections to existing valves, reinstate water supply, refill, install corrosion inhibitor, vent and test, and remove waste and debris.

703037 R RADIATOR:RENEW DOUBLE CONVECTOR NE 1800X600 IT 248.50 Radiator:Shut off valves and drain down, remove and renew with

double panel convector radiator and brackets, ready primed, ne 1800x600mm, make all connections to existing valves, reinstate water supply, refill, install corrosion inhibitor, vent and test, and remove waste and debris.

703039 R RADIATOR:RENEW DOUBLE CONVECTOR OVER 1800X600 IT 444.05 Radiator:Shut off valves and drain down, remove and renew with

double panel convector radiator and brackets, ready primed, over 1800x600mm, make all connections to existing valves, reinstate water supply, refill, install corrosion inhibitor, vent and test, and remove waste and debris.

Relocate Radiators 760001 X RADIATOR:RELOCATE POSITION IT 157.50 Radiator:Relocate position of radiator, isolate, drain down, remove,set

aside radiator for reuse, cut back flow and return pipework to floor or ceiling void and run new pipework to relocated position including all bends, connectors, clips etc, refix existing radiator in new position, connect to new new flow and return pipework, refill and recommission the heating system, including installing corrosion inhibitor, vent and test, and remove waste and debris.

Page 255: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

221 Local Space Housing

Heated Towel Rail 703201 R TOWEL RAIL:RENEW HEATED IT 198.95 Towel Rail:Shut off valves, drain, disconnect, clear away and renew

heated towel rail, 645x625mm, 2338 BTU/hour, with brackets, make all connections to valves, vent, test, and remove waste and debris.

Radiator - Valves 701001 U RADIATOR VALVE:RENEW VALVE AND DRAIN DOWN IT 47.02 Radiator Valve:Renew 15mm diameter handwheel or lockshield

single entry radiator valve including drain down and vent system, reinstate water supply, install corrosion inhibitor, and test on completion, and remove waste and debris.

701003 R RADIATOR VALVE:RENEW WHILST SYSTEM DRAINED IT 9.80 Radiator Valve:Renew 15mm diameter handwheel or lockshield

single entry radiator valve whilst system is drained for associated work.

701005 U RADIATOR VALVE:RENEW THERMOSTATIC AND DRAIN DOWN IT 51.74 Radiator Valve:Renew 15mm diameter thermostatic radiator valve,

including drain down and vent system, reinstate water supply, install corrosion inhibitor and test on completion, and remove waste and debris.

701007 R RADIATOR VALVE:RENEW THERMOSTATIC SYSTEM DRAINED IT 13.95 Radiator Valve:Renew 15mm diameter thermostatic radiator valve

whilst system is drained for associated work.

701011 E RADIATOR VALVE:OVERHAUL ANY TYPE NO 46.86 Radiator Valve:Overhaul any radiator valve including turn supplies

off/on, drain down/refill as required, repack, reseat, deburr spindle, repair leaking valve, renew plastic cap, install corrosion inhibitor and test on completion, and remove waste and debris.

Airlocks/Reprime 704001 U AIRLOCKS:CLEAR AIRLOCKS IT 51.75 Airlocks:Clear airlocks from heating system including venting

radiators and balance system.

704005 U REPRIME:REPRIME PRESSURISED SYSTEM COMPLETE IT 20.13 Reprime:Reprime pressurised system including vent and test

system.

Power Flushing 760101 X POWER FLUSH:EXISTING HEATING SYSTEM IT 126.50 Power Flush:Undertake power flushing of existing heating systems when

specifically instructed by Client Representative during installation of new boiler or whilst extending existing installation, and remove waste and debris.

Page 256: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

222 Local Space Housing

Solid Fuel Appliances, Flue Linings and Pipes Solid Fuel Backboilers 707001 R BACKBOILER:RENEW MILD STEEL COMPLETE NO 519.54 Backboiler:Renew high output mild steel backboiler, of approved

type to BS4834, remove fire surround, hearth and fireback and set aside, cut away brickwork to expose backboiler, drain system, disconnect and remove existing and install new backboiler, make good brickwork, refill system, install corrosion inhibitor and heat test boiler and all newly made joints, refix fire surround and hearth and make good plasterwork and decorations, and remove waste and debris.

707003 R BACKBOILER:DESCALE AND OVERHAUL NO 18.70 Backboiler:Descale, overhaul and clean pipes during backboiler

renewal.

707005 R BACKBOILER:RESET THERMOSTAT IT 11.50 Backboiler:Reset thermostat to any backboiler when appliance is

cold.

707007 U BACKBOILER:RENEW THERMOSTAT IT 42.76 Backboiler:Renew thermostat to any backboiler, and remove waste

and debris.

Multi-Fuel Roomheater with Boiler 711001 R BOILER:RENEW FREESTANDING MULTI-FUEL IT 622.08 Boiler:Renew freestanding roomheater with boiler with multi-fuel

roomheater with boiler, rated outputs 34500 BTU/hr to water and 10600 BTU/hr to room including turn water off/on, drain down as necessary, disconnect and remove existing unit, install new unit complete and reconnect and test supplies including any adapting of pipework and fittings, clean/sweep flue as necessary and remake all connections, make good to hearth and surround and remove waste and debris, unit to be installed in accordance with manufacturers instructions.

711003 R BOILER:RENEW INSET MULTI-FUEL IT 621.98 Boiler:Renew inset roomheater with boiler with multi-fuel

roomheater with boiler, rated outputs 34500 BTU/hr to water and 10600 BTU/hr to room including turn water off/on, drain down as necessary, disconnect and remove existing unit, install new unit complete and reconnect and test supplies, adapt pipework and fittings, modify opening, clean/sweep flue as necessary and remake all connections, make good to hearth and surround and remove waste and debris, unit to be installed in accordance with manufacturers instructions.

Page 257: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

223 Local Space Housing

Roomheater with Boiler 712013 R BOILER:RENEW WITH PARKRAY 99-FREESTANDING IT 753.68 Boiler:Renew Parkray 99 freestanding roomheater with boiler

including turn water off/on, drain down as necessary, disconnect and remove existing unit, install new unit complete and reconnect and test supplies including any adaptions of pipework and fittings, and fittings, clean/sweep flue and remake flue connections, make good to hearth and surround and remove waste and debris, unit to be installed in accordance with manufacturers instructions.

712015 R BOILER:RENEW WITH PARKRAY 99-INSET IT 782.68 Boiler:Renew Parkray 99 inset roomheater with boiler including turn

water off/on, drain down as necessary, disconnect and remove existing unit, modify opening as necessary and install new unit complete, reconnect and test supplies including any adapting of pipework and fittings, clean/sweep flue and remake flue connections, make good to hearth and surround and remove waste and debris, unit to be installed in accordance with manufacturers instructions.

712017 R BOILER:RENEW WITH PARKRAY 111-FREESTANDING IT 814.18 Boiler:Renew Parkray 111 freestanding roomheater with boiler

including turn water off/on, drain down as necessary, disconnect and remove existing unit, install new unit complete and reconnect and test supplies including any adaptions of pipework and fittings, clean/sweep flue and remake flue connections, make good to hearth and surround and remove waste and debris, unit to be installed in accordance with manufacturers instructions.

712019 R BOILER:RENEW WITH PARKRAY 111-INSET IT 844.28 Boiler:Renew Parkray 111 inset roomheater with boiler including

turn water off/on, drain down as necessary, disconnect and remove existing unit, modify opening as necessary and install new unit complete, reconnect and test supplies including any adapting of pipework and fittings, clean/sweep flue and remake flue connections, make good to hearth and surround and remove waste and debris, unit to be installed in accordance with manufacturers instructions.

Flue Lining and Pipes 709001 R FLUE:INSTALL FLEXIBLE LINER COMPLETE IT 376.52 Flue:Supply and fix new stainless steel flue liner kit ne 7.62m long

complete with clamp/plate, nose cone, draw cord and terminal including all necessary preparation work and making good on completion, and remove waste and debris.

709003 R FLUE:REMOVE FLUE LINER IT 80.23 Flue:Remove flexible flue liner from any flue and make good and

remove waste and debris.

709007 R FLUE:RENEW VE CAST IRON PIPE BEND IT 90.16 Flue:Renew vitreous enamel cast iron flue pipe bend with access

plate including remove existing, fix new including remake all joints and connections and remove waste and debris.

Page 258: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

224 Local Space Housing

709009 R FLUE:RENEW 125MM STAINLESS STEEL PIPE IT 224.04 Flue:Renew 125mm stainless steel twin wall flue pipe ne 1.0m long

including remove existing, fix new with clips, remake all joints and appliance connections and remove waste and debris.

709011 R FLUE:RENEW STAINLESS STEEL ELBOW IT 166.47 Flue:Renew 125mm stainless steel twin wall flue elbow including

remove existing, fix new and remake all joints and connections and remove waste and debris.

709013 R FLUE:RENEW METAL SOFFIT PLATE IT 28.93 Flue:Renew metal soffit plate with perforation for flue, drill and

screw to soffit of heater recess and make good, and remove waste and debris.

709015 R FLUE:RENEW ALUMINIUM SOOT DOOR IT 76.48 Flue:Renew soot door with ne 225x225mm aluminium double soot

door and frame to flue, remove existing, adjust size of opening to brick flue, bed frame in mortar, fix door and make good, and remove waste and debris.

709017 R FLUE:FIX NEW ALUMINIUM SOOT DOOR IT 93.99 Flue:Fix new ne 225x225mm aluminium double soot door and

frame to flue, cut opening in flue to suit, bed frame in mortar, fix door and make good, and remove waste and debris.

Heating Boilers Controls Boiler Controls 710001 U BOILER:RENEW THERMOSTAT IT 30.18 Boiler:Renew thermostat to central heating boiler including make

connections, make good finishes and test, and remove waste and debris.

710003 U BOILER:RENEW ROOM THERMOSTAT IT 33.43 Boiler:Renew room thermostat to central heating system including

make connections, make good finishes and test, and remove waste and debris.

710005 U BOILER:RENEW PROGRAMMER IT 82.10 Boiler:Renew central heating programmer with microelectric time

controller including make all connections and test, and remove waste and debris.

710007 U BOILER:RENEW CENTRAL HEATING TIME CLOCK IT 73.97 Boiler:Renew central heating time clock including make all

connections and test, and remove waste and debris.

710009 E BOILER:REMEDY FAULT TO CONTROLS IT 23.72 Boiler:Remedy fault to central heating controls including test all

wiring and components, check fuses and appliances, adjust controls, rectify minor faults on completion, provide report to Client Representative.

Page 259: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

225 Local Space Housing

Gas Point, Water and Space Heating Appliances Gas Fires 721001 U FIRE:REFIX LOOSE GAS FIRE NO 18.25 Fire:Remove if required and refix any type of loose gas fire

including turn supply off/on, secure fitting including any plugging, remake joints to supply and flue, check operation, test and leave in working order and remove waste and debris.

721003 U FIRE:RENEW GAS FIRE IT 237.75 Fire:Renew gas fire including turn off supply and remove existing

fire, inspect and connect flue plate, supply and fix new fire, reconnect supply and adapt opening if required and test, make good plaster and skirting if necessary and make good decorations, and remove waste and debris.

721004 U FIRE:RENEW GAS FIRE WITH BACKBOILER IT 532.00 Fire:Renew gas fire and backboiler max 55000 BTU/hr including

isolate supplies, drain down and remove existing fire and backboiler, inspect and connect flue plate, fix new fire and backboiler, adjust pipework, connect to supply including adapt opening if required, refill including corrosion inhibiter, test, remake all electrical connections, make good plaster, skirting and decorations, fire and boiler to be installed in accordance with manufacturers instructions and left in working order, and remove waste and debris.

721005 U FIRE:RENEW BALANCED FLUE GAS FIRE IT 611.26 Fire:Renew balanced flue gas fire including turn off supply and

remove existing fire, supply and fix new fire, reconnect supply including adapt opening if required and test, make good plaster, skirting and decorations and external structure and finishes, and remove waste and debris.

721007 R FIRE:SUPPLY AND FIX NEW GAS FIRE IT 278.24 Fire:Supply and fix new gas fire, inspect and connect flue plate, fix

fire, connect to supply to nearest suitable point, adapt opening as necessary and test, make good plaster, skirting if necessary and make good decorations; and remove waste and debris. .

721009 R FIRE:SUPPLY AND FIX NEW BALANCED FLUE GAS FIRE IT 677.64 Fire:Supply and fix new balanced flue gas fire including remove any

existing fire, cut/form opening for balanced flue, fix fire including connect to nearest point and test, and remove waste and debris, make good plaster, skirting and decorations internally and structure and finishes externally and remove waste and debris.

721011 U FIRE:RENEW RADIANTS TO GAS FIRE IT 35.75 Fire:Renew radiants to any type of gas fire including dismantle as

necessary, install new radiants to suit and reassemble and test on completion, and remove waste and debris.

Gas Water Heaters 722001 U WATER HEATER:RENEW INSTANTANEOUS TO SINK IT 168.38 WaterHeater:Renew instantaneous gas sink water heater including

turn off supplies and remove existing heater, supply and fix new heater, adjust pipework, reconnect and test, and remove waste and debris.

Page 260: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

226 Local Space Housing

722003 U WATER HEATER:RENEW GAS MULTIPOINT TYPE IT 300.63 Water Heater:Renew multipoint gas water heater with balanced flue

including turn off supplies and remove existing heater, supply and fix new heater, adjust pipework, reconnect and test, and remove waste and debris.

722005 R WATER HEATER:SUPPLY GAS INSTANTANEOUS TO SINK IT 223.49 Water Heater:Supply and fix new instantaneous gas sink water

heater including turn off supplies, drain down, supply and fix new heater, adjust pipework and connect to supplies, refill and test, cut out wall for balanced flue and make good all finishes, and remove waste and debris.

722007 R WATER HEATER:SUPPLY GAS MULTIPOINT TYPE IT 351.05 Water Heater:Supply and fix new multipoint gas water heater with

balanced flue including turn off supplies, drain down, supply and fix new heater, adjust pipework and connect to supplies, refill and test, cut out wall for balanced flue and make good all finishes, and remove waste and debris.

Gas Boilers to Sedbuk ’A’ Rating Additional Builders Work 723101 U BOILER:ADDITIONAL MAKING GOOD NEW BOILER LOCATION IT 133.50 Boiler:Additional making good if new boiler is not located in same position

as original heating source, all balanced flue openings to be infilled with brickwork cut, toothed and bonded to match existing on external face, and plastered internally in making good, all backboiler openings to be blocked up with blockwork cut, toothed and bonded, opening for and including air vent, and plastered in making good, supply and fix new skirting decorated to match existing, and redecorate walls as appropriate or supply tenant with decorating voucher, and remove waste and debris.

Gas Boilers in Original Position 723201 U BOILER:RENEW WITH COMBINATION BOILER - EXISTING IT 1293.36 Boiler:Renew central heating/hot water boiler with wall mounted

condensing combination boiler max 80000 BTU/hr [PC Sum for supply and delivery of Boiler, Flue and Fixing Jig £600.00 excluding VAT] including isolate supplies, drain down and remove existing boiler, supply and fix new boiler with balanced flue in original position in dwelling, reform flue opening through external wall including all additional builders work, adjust gas, supply and flow and return pipework and connect to supplies, provide new programmer, pump, motorised valve, cylinder and room stats, and thermostatic radiator valves for upto 7 radiators, refill including corrosion inhibitor and test, remake all electrical connections including bonding, and make good all finishes, and remove waste and debris, boiler to be installed in accordance with manufacturers instructions and left in full working order.

Page 261: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

227 Local Space Housing

723203 U BOILER:RENEW COMBINATION AND PRESSURE VESSEL IT 1313.86 Boiler:Renew central heating/hot water boiler with wall mounted

condensing combination boiler max 80000 BTU/hr [PC Sum for supply and delivery of Boiler, Pressure Vessel, Flue and Fixing Jig £550.00 excluding VAT] including isolate supplies, drain down and remove existing boiler, supply and fix new boiler with balanced flue in original position in dwelling, reform flue opening through external wall including all additional builders work, adjust gas, supply and flow and return pipework and connect to supplies, provide new pressure vessel, programmer, pump, motorised valve, cylinder and room stats, and thermostatic radiator valves for upto 7 radiators, refill including corrosion inhibitor and test, remake all electrical connections including bonding, and make good all finishes, and remove waste and debris, boiler to be installed in accordance with manufacturers instructions and left in full working order.

723205 U BOILER:RENEW WITH CONDENSING BOILER - EXISTING IT 1293.36 Boiler:Renew central heating/hot water boiler with wall mounted

condensing boiler max 80000 BTU/hr hr [PC Sum for supply and delivery of Boiler, Flue and Fixing Jig £600.00 excluding VAT] including isolate supplies, drain down and remove existing boiler, supply and fix new boiler with balanced flue in original position in dwelling, reform flue opening through external wall including all additional builders work, adjust gas, supply and flow and return pipework and connect to supplies, provide new programmer, pump, motorised valve, cylinder and room stats, and thermostatic radiator valves for upto 7 radiators, refill including corrosion inhibitor and test, remake all electrical connections including bonding, and make good all finishes, and remove waste and debris, boiler to be installed in accordance with manufacturers instructions and left in full working order.

Gas Boilers in New Position 723301 U BOILER:RENEW WITH COMBINATION BOILER-NEW IT 1307.85 Boiler:Renew central heating/hot water boiler with wall mounted

condensing combination boiler max 80000 BTU/hr [PC Sum for supply and delivery of Boiler, Flue and Fixing Jig £600.00 excluding VAT] including isolate supplies, drain down and remove existing boiler, supply and fix new boiler with balanced flue in new position in dwelling, form flue opening through external wall including all additional builders work, extend gas, supply and flow and return pipework and connect to supplies, provide new programmer, pump, motorised valve, cylinder and room stats, and thermostatic radiator valves for upto 7 radiators, refill including corrosion inhibitor and test, remake all electrical connections including bonding, and make good all finishes, [additional builders works associated with making good of original flue opening to be claimed against Item 723101] and remove waste and debris, boiler to be installed in accordance with manufacturers instructions and left in full working order.

Page 262: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

228 Local Space Housing

723303 U BOILER:RENEW COMBINATION AND PRESSURE VESSEL-NEW IT 1351.35 Boiler:Renew central heating/hot water boiler with wall mounted

condensing combination boiler max 80000 BTU/hr [PC Sum for supply and delivery of Boiler, Pressure Vessel, Flue and Fixing Jig £550.00 excluding VAT] including isolate supplies, drain down and remove existing boiler, supply and fix new boiler with balanced flue in new position in dwelling, form flue opening through external wall including all additional builders work, adjust gas, supply and flow and return pipework and connect to supplies, provide new pressure vessel programmer, pump, motorised valve, cylinder and room stats, and thermostatic radiator valves for upto 7 radiators, refill including corrosion inhibitor and test, remake all electrical connections including bonding, and make good all finishes, [additional builders works associated with making good of original flue opening to be claimed against Item 723101] and remove waste and debris, boiler to be installed in accordance with manufacturers instructions and left in full working order.

723305 U BOILER:RENEW WITH CONDENSING BOILER - NEW IT 1376.85 Boiler:Renew central heating/hot water boiler with wall mounted

condensing boiler max 80000 BTU/hr hr [PC Sum for supply and delivery of Boiler, Flue and Fixing Jig £600.00 excluding VAT] including isolate supplies, drain down and remove existing boiler, supply and fix new boiler with balanced flue in new position in dwelling, reform flue opening through external wall including all additional builders work, adjust gas, supply and flow and return pipework and connect to supplies, provide new programmer, pump, motorised valve, cylinder and room stats, and thermostatic radiator valves for upto 7 radiators, refill including corrosion inhibitor and test, remake all electrical connections including bonding, and make good all finishes, [additional builders works associated with making good of original flue opening to be claimed against Item 723101] and remove waste and debris, boiler to be installed in accordance with manufacturers instructions and left in full working order.

Domestic Gas Cookers Domestic Gas Cooker - Fault Locating 722101 U GAS COOKER:RESPONSE CALL-OUT IT 17.25 Gas Cooker:Response call-out to any type of domestic gas cooker

supplied by Client, locate fault, including any necessary testing and report to Client Representative.

722103 U GAS COOKER:RESPONSE AND RECTIFY CALL-OUT IT 105.34 Gas Cooker:Response call-out to any type of domestic gas cooker

supplied by Client, locate fault, including any necessary testing and report to Client Representative, carry out minor renewals/repairs/ remedial works to remedy fault including all necessary labour, plant and material (material cost allowance £35.00) test operation of equipment/installation, and remove waste and debris.

Domestic Gas Cooker - Renewals 722121 R GAS COOKER UNIT:RENEW COMPLETE NO 380.30 Gas Cooker Unit:Isolate supply, disconnect existing, clear away,

supply and install new gas cooker complete, reconnect, carry out gas tests on cooker and pipework and leave in working order and remove waste and debris.

Page 263: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

229 Local Space Housing

722131 R GAS COOKER:RENEW GRILLE PAN NO 37.47 Gas Cooker:Renew grille pan to gas domestic cooker and remove

waste and debris.

722132 R GAS COOKER:RENEW GRILLE PAN GRID NO 9.38 Gas Cooker:Renew grille pan grid to gas domestic cooker and

remove waste and debris.

722133 R GAS COOKER:RENEW TOP PLATE NO 45.84 Gas Cooker:Renew top plate to gas domestic cooker and remove

waste and debris.

722134 R GAS COOKER:RENEW CAKE TRAY NO 11.55 Gas Cooker:Renew cake tray to gas domestic cooker and remove

waste and debris.

722135 R GAS COOKER:RENEW BURNER NO 24.76 Gas Cooker:Renew burner to gas domestic cooker and remove

waste and debris.

722136 R GAS COOKER:RENEW CONTROL KNOB NO 9.95 Gas Cooker:Renew control knob to gas domestic cooker and

remove waste and debris.

722137 R GAS COOKER:RENEW DOOR HANDLE NO 17.14 Gas Cooker:Renew door handle to gas domestic cooker and remove

waste and debris.

722138 R GAS COOKER:RENEW SELF CLEANING PANEL NO 29.96 Gas Cooker:Renew self cleaning panel to gas domestic cooker and

remove waste and debris.

722139 R GAS COOKER:RENEW LIGHTER NO 18.01 Gas Cooker:Renew gas lighter to gas domestic cooker and remove

waste and debris.

Domestic Gas Cookers - Supply Hoses 722141 R GAS COOKER:RENEW SUPPLY HOSE 500MM NO 31.88 Gas Cooker:Renew 500mm long proprietary gas supply hose with

snap fit connectors to supply outlet and to domestic gas cooker and remove waste and debris.

722143 R GAS COOKER:RENEW SUPPLY HOSE 1000MM NO 39.93 Gas Cooker:Renew 1000mm long proprietary gas supply hose with

snap fit connectors to supply outlet and to domestic gas cooker and remove waste and debris.

Domestic Gas Cookers - Void Works 740001 U GAS COOKER:DISCONNECT BAYONET TYPE SEAL MAKE SAFE NO 8.77 Gas Cooker:Isolate supply and disconnect any gas cooker (bayonet

type fitting) and leave safe.

740003 U GAS COOKER:DISCONNECT SEAL CAP MAKE SAFE NO 9.90 Gas Cooker:Isolate supply and disconnect any gas cooker, cap off

supply pipework and leave safe.

Page 264: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

230 Local Space Housing

740005 U GAS COOKER:RECONNECT WITH BAYONET TEST NO 6.90 Gas Cooker:Connect or reconnect any gas cooker with bayonet type

fitting, test and leave in working order.

740007 U GAS COOKER:RECONNECT AND TEST NO 11.50 Gas Cooker:Connect or reconnect any gas cooker including

removing temporary capping to supply, test and leave in working order.

740043 U GAS COOKER:RENEW STABILITY CHAIN NO 9.69 Gas Cooker:Renew or install gas cooker stability chain in

accordance with the manufacturer’s instructions and remove waste and debris..

740045 R GAS COOKER:SUPPLY OR RENEW SUPPLY BAYONET FITTING NO 13.66 Gas Cooker:Isolate supply to any gas cooker point, remove existing

bayonet socket, capped end or other fitting, renew or supply and fix new bent or straight bayonet socket fitting screwed to existing supply pipe, test and leave safe and remove waste and debris.

740047 R GAS COOKER:SUPPLY OR RENEW BAYONET AND EXTEND PIPE NO 28.01 Gas Cooker:Isolate supply to any gas point, remove existing capped

end or any other fitting, extend existing supply pipe by upto 3.00m using copper pipe and fittings, supply and fix new bent or straight bayonet socket fitting, test and leave safe and remove waste and debris..

Void Works Void Property Works 730001 X VOID:REMOVE ANY GAS APPLIANCE AND SEAL SUPPLY IT 28.77 Void:Remove any type of existing gas appliance and seal off supply

and remove waste and debris..

730003 X VOID:BLANK OFF REDUNDANT POINT IT 10.80 Void:Blank off redundant gas point and test upon completion. 730005 X VOID:TEST AND COMMISSION CENTRAL HEATING SYSTEM IT 34.50 Void:Carry out all necessary tests and commission central heating

system complete and leave in full working order.

730007 X VOID:CHECK AND TEST GAS INSTALLATION IT 23.00 Void:Carry out complete check and test on gas installation to any

property and provide report to the Client Representative.

730009 X VOID:SAFETY CHECK AND TEST GAS INSTALLATION IT 51.75 Void:Carry out complete Landlords gas safety check and testing to

all gas appliances and installation to any property and provide Landlords Gas Safety Check Report (CP12) to the Client Representative.

730011 X VOID:TEMPORARY CAP GAS SUPPLY IT 18.71 Void:Temporary cap gas supply to void property, attend and

remove cap on reoccupation of property

Page 265: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

231 Local Space Housing

Draining Down 713001 X VOID:DRAIN DOWN CENTRAL HEATING IT 14.38 Void:Drain down central heating water system to void property. 713003 X VOID:REFILL CENTRAL HEATING IT 61.94 Void:Refill central heating system to void and introduce approved

rust inhibitor to system, fire up and test.

Page 266: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

232 Local Space Housing

ELECTRICAL Space Point and Water Heating Appliances Storage Heaters 810001 U HEATER:RENEW NE 1.7KW STORAGE HEATER NO 255.03 Heater:Isolate supply, disconnect existing, clear away and renew ne

1.7 kilowatt storage heater, make all connections, including fixing securely to wall, electrical tests and leave in working order and remove waste and debris.

810002 U HEATER:RENEW NE 0.6KW STORAGE TO BATHROOM NO 202.71 Heater:Isolate supply, disconnect existing, clear away and renew ne

0.6 kilowatt storage heater to bathroom, make all connections, including fixing securely to wall, electrical tests and leave in working order and remove waste and debris.

810003 U HEATER:RENEW NE 2.6KW STORAGE HEATER NO 322.41 Heater:Isolate supply, disconnect existing, clear away and renew ne

2.6 kilowatt storage heater, make all connections, including fixing securely to wall, electrical tests and leave in working order and remove waste and debris.

810005 U HEATER:RENEW NE 3.4KW STORAGE HEATER NO 376.69 Heater:Isolate supply, disconnect existing, clear away and renew ne

3.4 kilowatt storage heater, make all connections, including fixing securely to wall, electrical tests and leave in working order and remove waste and debris.

Combination Storage/Convector Heaters 811001 U HEATER:RENEW 1.7 AND 1.0KW COMBINED STORAGE NO 329.23 Heater:Isolate supply, disconnect existing, clear away and renew

storage heater with combination storage and convector heater, ne 1.7 kilowatt storage and ne 1.0 kilowatt convector, make all connections including fix securely to wall, electrical tests and leave in working order and remove waste and debris.

811003 U HEATER:RENEW 2.6 AND 1.5KW COMBINED STORAGE NO 383.45 Heater:Isolate supply, disconnect existing, clear away and renew

storage heater with combination storage and convector heater, ne 2.6 kilowatt storage and ne 1.5 kilowatt convector, make all connections including fix securely to wall, electrical tests and leave in working order and remove waste and debris.

811005 U HEATER:RENEW 3.4 AND 2.0KW COMBINED STORAGE NO 485.85 Heater:Isolate supply, disconnect existing, clear away and renew

storage heater with combination storage and convector heater, ne 3.4 kilowatt storage and ne 2.0 kilowatt convector, make all connections including fix securely to wall, electrical tests and leave in working order and remove waste and debris.

Page 267: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

233 Local Space Housing

Storage Heaters - Repairs 813006 U HEATER:RENEW ANY PARTS TO STORAGE (PER HEATER) IT 30.41 Heater:Isolate supply, disconnect, clear away and renew necessary

parts to any size storage heater including thermalink, thermostat, control knob, microtherm panel, porcelain block, cutout, lower harness, upper harness, wiring loom including dismantle and reassemble storage heater and access covers, set or reset thermostat, reconnect electricity supply, electrical tests and leave in working order and remove waste and debris.

813019 R HEATER:RESITE AND RECONNECT NO 29.01 Heater:Isolate supply, disconnect and resite night storage heater,

including dismantle and reassemble, move to new site, secure to wall, and make all connections, reconnect electricity supply, electrical tests and leave in working order and remove waste and debris.

813021 R HEATER:DISCONNECT AND REMOVE NO 24.88 Heater:Isolate supply, disconnect and remove to secure store for

subsequent re-use any night storage heater and make safe existing supply.

813035 U THERMOSTAT:RENEW ROOM TYPE TO ELECTRIC HEATING NO 22.80 Thermostat:Isolate supply, disconnect, clear away and renew high

limit room thermostat, including make all connections and leave in working order and remove waste and debris.

813039 U HEATER:SERVICE ANY TYPE OF STORAGE HEATER NO 18.48 Heater:Attend property and carry out service to any type of electric

storage heater including provision of minor parts as necessary, test and leave in working order and remove waste and debris.

Radiant and Convector Heaters 815001 U FIRE:RENEW NE 2.5KW RADIANT FIRE NO 133.45 Fire:Isolate supply, disconnect, clear away and renew with ne 2.5

kilowatt focalpoint radiant fire, make all necessary connections into spur box reconnect electricity supply, electrical tests and leave in working order and remove waste and debris.

815003 U HEATER:RENEW 2.5KW FAN CONVECTOR HEATER NO 78.64 Heater:Isolate supply, disconnect, clear away and renew or install

ne 2.5 kilowatt fan-assisted convector heater, including plugging and screwing securely to wall, make all necessary connections into spur box, reconnect electricity supply, electrical tests and leave in working order and remove waste and debris.

815005 U HEATER:RENEW 2.5KW FAN CONVECTOR WITH TIMER NO 94.46 Heater:Isolate supply, disconnect, clear away and renew or install

ne 2.5 kilowatt fan-assisted convector heater including 24hr timer, plugging and screwing securely to wall, make all necessary connections into spur box, reconnect electricity supply, electrical tests and leave in working order and remove waste and debris.

Page 268: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

234 Local Space Housing

815007 U HEATER:RENEW NE 1KW PANEL HEATER NO 97.25 Heater:Isolate supply, disconnect, clear away and renew ne 1

kilowatt panel heater including plugging and screwing securely to wall, make all necessary connections into spur box, reconnect electricity supply, electrical tests and leave in working order and remove waste and debris.

815009 U HEATER:RENEW NE 1KW PANEL HEATER WITH TIMER NO 116.63 Heater:Isolate supply, disconnect, clear away and renew ne 1

kilowatt panel heater with 24hr timer including plugging and screwing securely to wall, make all necessary connections into spur box reconnect electricity supply, electrical tests and leave in working order and remove waste and debris.

815011 U HEATER:RENEW NE 2KW PANEL HEATER NO 111.80 Heater:Isolate supply, disconnect, clear away and renew ne 2

kilowatt panel heater including plugging and screwing securely to wall, make all necessary connections into spur box, reconnect electricity supply, electrical tests and leave in working order and remove waste and debris.

815013 R HEATER:RENEW NE 2KW PANEL HEATER WITH TIMER NO 133.35 Heater:Isolate supply, disconnect, clear away and renew ne 2

kilowatt panel heater with 24hr timer including plugging and screwing securely to wall, make all necessary connections into spur box reconnect electricity supply, electrical tests and leave in working order and remove waste and debris.

815015 U HEATER:RENEW NE 3KW PANEL HEATER NO 132.44 Heater:Isolate supply, disconnect, clear away and renew ne 3

kilowatt panel heater including plugging and screwing securely to wall, make all necessary connections into spur box, reconnect electricity supply, electrical tests and leave in working order and remove waste and debris.

815017 U HEATER:RENEW NE 3KW PANEL HEATER WITH TIMER NO 152.91 Heater:Isolate supply, disconnect, clear away and renew ne 3

kilowatt panel heater with 24hr timer including plugging and screwing securely to wall, make all necessary connections into spur box reconnect electricity supply, electrical tests and leave in working order and remove waste and debris.

815019 U FIRE:RENEW NE 1KW INFRA RED HEATER NO 59.27 Fire:Isolate supply, disconnect, clear away and renew with ne 1

kilowatt infra red wall mounted heater with pull cord, fix securely to wall, make all necessary connections into spur box, reconnect electrical tests and leave in working order and remove waste and debris.

815020 U HEATER:SERVICE ANY TYPE OF PANEL HEATER NO 18.48 Heater:Attend property and carry out service to any type of

electric panel heater including provision of minor parts as necessary, test and leave in working working order and remove waste and debris.

Page 269: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

235 Local Space Housing

815021 U FIRE:RENEW NE 2KW INFRA RED HEATER NO 64.04 Fire:Isolate supply, disconnect, clear away and renew with ne 2

kilowatt infra red wall mounted heater with pull cord, fix securely to wall, make all necessary connections into spur box, reconnect electrical tests and leave in working order and remove waste and debris.

815023 U HEATER:RENEW 2KW WALL FAN HEATER NO 110.29 Heater:Isolate supply, disconnect, clear away and renew or install

ne 2 kilowatt wall mounted fan heater, including plugging and screwing securely to wall, make all necessary connections into spur box, reconnect electricity supply, electrical tests and leave in working order and remove waste and debris.

815025 U HEATER:RENEW 2KW WALL FAN HEATER WITH TIMER NO 81.25 Heater:Isolate supply, disconnect, clear away and renew or install

ne 2 kilowatt wall mounted fan heater with 24hr timer, including plugging and screwing to wall, make all necessary connections to spur box, reconnect electricity supply, electrical tests and leave in working order and remove waste and debris.

Radiant and Convector Heaters - Repairs 817001 U HEATER:RENEW RADIANT ELEMENT NO 41.84 Heater:Isolate supply, disconnect, clear away and renew infra-red

silica heater element to radiant heater including dismantle and reassemble any access covers, reconnect electricity supply, test and leave in working order and remove waste and debris.

817003 U HEATER:RENEW RADIANT REFLECTOR NO 29.45 Heater:Isolate supply, disconnect, clear away and renew reflector

panel, secure into place on radiant heater, including dismantle and reassemble any access covers, reconnect electricity supply, test and leave in working order and remove waste and debris.

817007 U HEATER:RENEW DP SWITCH NO 16.12 Heater:Isolate supply, disconnect, clear away and renew double

pole control switch to heater, including dismantle and reassemble any access covers, reconnect electricity supply, test and leave in working order and remove waste and debris.

817011 R FIRE OR RADIANT HEATER:SERVICE ANY TYPE NO 18.48 Fire or Radiant Heater:Attend property and carry out service to any

type of electric fire or radiant heater including provision of minor parts as necessary, test and leave in working order and remove waste and debris.

Electric Towel Rail 819001 R TOWEL RAIL:RENEW NE 175 WATT ELECTRIC NO 120.55 Towel Rail:Isolate supply, disconnect, clear away and renew towel

rail ne 175 watt, free standing or wall mounted including plug and screw to wall in accordance with manufacturers instructions, make all necessary connections into spur box, reconnect, electrical tests and leave in working order and remove waste and debris.

Page 270: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

236 Local Space Housing

Immersion Heaters 820003 U IMMERSION HEATER:RENEW 3KW ALLOY (TOP) NO 41.61 Immersion Heater:Isolate supply, drain down, disconnect, clear

away, renew top entry immersion with 3KW alloy-sheathed immersion heater to copper cylinder refill, test and vent system, refix, test and reset thermostat, make all necessary connections, reconnect electricity supply and undertake electrical tests and remove waste and debris.

820007 U IMMERSION HEATER:RENEW NE 3KW ALLOY (BOTTOM) NO 61.48 Immersion Heater:Isolate supply, drain down, disconnect, clear

away, renew bottom entry immersion heater to copper cylinder with ne 3KW alloy- sheathed heater, refill test and vent system, refix, test reset thermostat, make all necessary connections, reconnect to electricity supply and undertake electrical tests and remove waste and debris.

820009 U IMMERSION HEATER:RENEW CYLINDER THERMOSTAT NO 14.11 Immersion Heater:Disconnect, clear away and renew any

thermostat to immersion heater.

820011 U IMMERSION HEATER:DISCONNECT NO 11.39 Immersion Heater:Isolate and disconnect faulty immersion

heater, fix temporary sealing box to exposed cable and leave safe.

820013 U IMMERSION HEATER:REMOVE AND SEAL BOSS IT 22.78 Immersion Heater:Isolate, disconnect and remove any defective

immersion heater, drain down as necessary, seal immersion boss, disconnect, fix temporary sealing box to exposed cable and leave safe, and remove waste and debris..

820015 U IMMERSION HEATER:RECONNECT AND TEST IT 19.87 Immersion Heater:Reconnect any immersion heater, and undertake

electrical test, and remove waste and debris.

820017 U IMMERSION HEATER:TEST AND RESET THERMOSTAT IT 10.22 Immersion Heater:Test and reset as necessary any immersion

heater thermostat.

820019 U IMMERSION HEATER:RENEW CIRCUIT AND SWITCH NO 132.98 Immersion Heater:Isolate supply, strip out, clear away and renew

immersion heater circuit with cable run in mini-trunking or rigid PVC conduit chased into wall etc., including fitting of 20 amp double pole isolator switch, 20 amp double pole indicator switch and reconnection of existing heater flex, reconnect electricity supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

820021 U IMMERSION HEATER:RENEW FLEX CONNECTION NO 18.21 Immersion Heater:Isolate supply, strip out, clear away and renew

1.00m length of 2.5mm 3 core butyl rubber flex to immersion heater and make all necessary connections to 20 amp double pole switch and immersion heater, reconnect electricity supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

Page 271: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

237 Local Space Housing

820023 U IMMERSION HEATER:RENEW 20A DP INDICATOR SWITCH NO 31.44 Immersion Heater:Isolate supply, disconnect, clear away and renew

20 amp moulded plastic double pole switch with neon indicator and moulded plastic mounting box, including plugging to walls as necessary, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

820025 U IMMERSION HEATER:RENEW BOOSTER SWITCH NO 24.19 Immersion Heater: Isolate supply, disconnect, clear away and

renew or supply and install immersion booster switch and and moulded plastic mounting box, including plugging to walls as necessary, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

Water Storage Heaters 825001 U WATER HEATER:RENEW 3KW 7 LITRE NO 145.15 Water Heater:Isolate water and electrical supplies, drain down,

disconnect, clear away and renew 3kW 7 litre water storage heater, reconnect water supply, refill and test, remake all connections, reconnect electricity supply, electrical tests and leave in working order on completion, and remove waste and debris.

825003 U WATER HEATER:RENEW 3KW 100 LITRE NO 549.82 Water Heater:Isolate water and electrical supplies, drain down,

disconnect, clear away and renew with 3kW, ne 100 litre water storage heater, reconnect water supply, refill and test, remake all connections, reconnect electricity supply, electrical tests and leave in working order on completion, and remove waste and debris.

825005 U WATER HEATER:RENEW 3KW NE 30 LITRE NO 368.17 Water Heater:Isolate water and electrical supplies, drain down,

disconnect, clear away and renew with 3kW, ne 30 litre water storage heater, reconnect water supply, refill and test, remake all connections, reconnect electricity supply, electrical tests and leave in working order on completion, and remove waste and debris.

825007 U WATER HEATER:RENEW SWITCH NO 38.37 Water Heater:Isolate supply, disconnect, clear away and renew 20

amp double pole immersion heater switch marked ‘WATER HEATER’, 2-hr run-back timer, neon indicator, and moulded plastic mounting box, including plugging walls as necessary, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

825009 U WATER HEATER:RENEW EC7 TIMER SWITCH NO 34.75 Water Heater:Isolate supply, disconnect, clear away and renew EC7

micro 24hr timer switch to water heater, dismantle and reassemble access covers, reset, reconnect electricity supply, electrical tests, leave in working order and remove waste and debris.

Page 272: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

238 Local Space Housing

Water Storage Heaters - Repairs 826001 U WATER HEATER:RENEW CONTROL SPINDLES NO 44.79 WaterHeater:Isolate supply, dismantle, clear away and renew

control spindles and racks to water heater, dismantle and reassemble access covers, reset, reconnect electricity supply, electrical tests and leave in working order and remove waste and debris.

Electric Heating Controls 827001 U PROGRAMMER:RENEW HEATING CONTOL TIME CLOCK NO 92.30 Programmer:Isolate supply, disconnect, clear away and renew any

Economy 7 time switch clock, remake all necessary connections, reconnect electricity supply, undertake electrical tests, make good and leave in working order and remove waste and debris.

Electrical Appliances Showers - Electric 830001 U SHOWER:INSTALL NEW NE 8.5KW UNIT NO 325.42 Shower:Supply and install new ne 8.5KW shower unit including

plugging walls as necessary, connect to water and electrical supplies including provision of shower circuit including mini-trunking or rigid PVC conduit chased in wall etc, incorporating RCD protection, MCB 45amp, DP switch and all adjustments to pipework and electrical supply as necessary, fill, test and undertake tests, provide certificate, make good to all finishes, and remove waste and debris.

830003 U SHOWER:RENEW NE 8.5KW UNIT NO 257.47 Shower:Isolate and disconnect water/electricity supplies, disconnect

and clear away existing and renew with ne 8.5KW shower unit including plug walls as necessary, adjust and reconnect water supply, fill, test all newly made joints and adjust, remake all connections to cables, install RCD protection to shower circuit if missing, MCB 45amp, reconnect electricity supply, and undertake tests, provide certificate, make good to all finishes, and remove waste and debris.

830005 U SHOWER:REMOVE REPAIR AND REFIX NO 65.26 Shower:Isolate and disconnect water and electric supplies, remove

shower, carry out minor repairs and refix, reconnect water and electricity supplies, test all newly made joints, and undertake electrical tests, make good all finishes, and remove waste and debris.

830007 R SHOWER:DISCONNECT SEAL AND MAKE SAFE NO 19.89 Shower:Isolate supply and disconnect shower unit, fix

temporary sealing box to exposed cable and leave safe.

830009 R SHOWER:RECONNECT AND TEST NO 25.98 Shower:Reconnect shower unit, test all supplies including carry out

electrical tests and leave in working order and remove waste and debris.

Page 273: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

239 Local Space Housing

830011 R SHOWER:RENEW CIRCUIT NO 141.15 Shower:Isolate supply, disconnect, strip out, clear away and renew

shower circuit including mini-trunking or rigid PVC conduit chased into wall etc, incorporating RCD protection, 40 amp DP switch and make all necessary connections, reconnect electricity supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

830013 R SHOWER:RENEW 45A CEILING SWITCH NO 36.32 Shower:Isolate supply, disconnect, clear away and renew 45 amp

one way moulded plastic double pole ceiling switch, neon indicator, fitted with ceiling switch cord of 1.5m length, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

Domestic Type Cookers 835001 R ELECTRIC COOKER:DISCONNECT SEAL AND MAKE SAFE NO 6.86 Electric Cooker:Isolate supply and disconnect electric cooker, fix

temporary sealing box to exposed cable and leave safe.

835003 R ELECTRIC COOKER:RECONNECT AND TEST NO 8.52 Electric Cooker:Reconnect cooker, carry out electrical tests and

leave in working order and remove waste and debris.

Domestic Type Cookers - Fault Locating 882001 R ELECTRIC COOKER:LOCATE FAULT IT 34.06 Electric Cooker:Locate fault in domestic cooker circuit or

connections including any necessary testing and report to Client Representative (any repairs required to be ordered separately, can only be claimed if instructed by Client Representative).

Domestic Type Cookers - Fault Locating/Repair 882011 R ELECTRIC COOKER:LOCATE FAULT AND REPAIR IT 72.83 Electric Cooker:Locate fault in domestic cooker circuit or

connections including any necessary testing undertake minor renewals or repairs to remedy fault (material cost allowance £5.00) and report to Client Representative and remove waste and debris. (can only be claimed if instructed by Client Representative).

Domestic Type Electric Cookers - Renewals 882021 R ELECTRIC COOKER:RENEWAL 4 PLATE TYPE NO 437.76 Electric Cooker:Isolate supply, disconnect existing, clear away,

supply and install new 4 plate domestic type electrical cooker complete, reconnect, undertake electrical tests, test operation and leave in working order and remove waste and debris.

882023 R ELECTRIC COOKER:RENEW 2 PLATE TYPE HOB UNIT NO 138.56 Electric Cooker Unit:Isolate supply, disconnect existing, clear away,

supply and install new 2 plate domestic type electric hob unit complete, reconnect, undertake electrical tests, test operation and leave in working order and remove waste and debris.

882031 R ELECTRIC COOKER:RENEW GRILL PAN NO 39.82 Electric Cooker:Renew grill pan to domestic type electric cooker and

remove waste and debris.

Page 274: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

240 Local Space Housing

882032 R ELECTRIC COOKER:RENEW GRILL PAN GRID NO 9.62 Electric Cooker:Renew grill pan grid to domestic type electric cooker

and remove waste and debris.

882033 R ELECTRIC COOKER:RENEW TOP PLATE NO 52.00 Electric Cooker:Renew top plate to domestic type electric cooker

and remove waste and debris.

882034 R ELECTRIC COOKER:RENEW CAKE TRAY NO 13.64 Electric Cooker:Renew cake tray to domestic type electric cooker

and remove waste and debris.

882035 R ELECTRIC COOKER:RENEW CONTROL KNOB NO 10.62 Electric Cooker:Renew control knob to domestic type electric cooker

and remove waste and debris.

882036 R ELECTRIC COOKER:RENEW GRILL PAN HANDLE NO 10.51 Electric Cooker:Renew grill pan handle to domestic type electric

cooker and remove waste and debris.

882037 R ELECTRIC COOKER:RENEW OVEN DOOR NO 71.25 Electric Cooker:Renew oven door to domestic type electric cooker

and remove waste and debris.

882038 R ELECTRIC COOKER:RENEW SELF CLEANING PANEL NO 53.74 Electric Cooker:Renew self cleaning panel to domestic type electric

cooker and remove waste and debris.

Cooker Control Units and Circuits 835005 U COOKER CONTROL UNIT:REMOVE REPAIR AND REFIX NO 36.96 Cooker Control Unit:Isolate supply and remove cooker control unit,

determine fault and carry out minor repairs, refix control unit, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

835007 U ELECTRIC COOKER:RENEW CIRCUIT NO 117.59 Electric Cooker:Isolate supply, strip out, clear away and renew

cooker circuit including fitting of wall mounted control box, cable run in mini-trunking or rigid PVC conduit chased into walls or drawn through existing conduit and make all necessary connections to existing cooker, reconnect electric supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

835009 U ELECTRIC COOKER:RENEW UNIT AND CIRCUIT NO 62.24 Electric Cooker:Isolate supply, strip out, clear away and renew link

circuit from cooker control unit to cooker outlet plate, cable run in mini- trunking or rigid PVC conduit chased into existing walls or drawn through existing conduit and make all connections to cooker control unit, supply and fix new cooker outlet plate and make connection to cooker, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

Page 275: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

241 Local Space Housing

835011 U ELECTRIC COOKER:RENEW CONTROL UNIT AND SWITCH NO 36.94 Electric Cooker:Isolate supply, disconnect, clear away and renew

45/50 amp surface mounted plastic cooker unit, with plastic mounting-box, and double pole switch, including plugging to walls as necessary, remake all necessary connections to cables, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

835013 U ELECTRIC COOKER:RENEW METAL CONTROL UNIT NO 55.25 Electric Cooker:Isolate supply, disconnect, clear away and renew

45/50 amp flush type metal cooker control unit and flush box, and double pole switch, including plugging to walls as necessary, remake all necessary connections to cables, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

835015 U ELECTRIC COOKER:RENEW CONTROL PLATE NO 36.72 Electric Cooker:Isolate supply, disconnect, clear away and renew

45/50 amp surface mounted cooker control unit plate with double pole switch, including plugging to walls as necessary, remake all necessary connections to cables, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

835019 U ELECTRIC COOKER:RENEW COOKER OUTLET PLATE NO 10.63 Electric Cooker:Isolate supply, disconnect, clear away and renew

cooker outlet plate and make connections to cooker link circuit and to cooker cable, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

Cooker Ventilation Hoods 836001 R ELECTRIC COOKER HOOD:SERVICE ANY TYPE NO 23.02 Electric Cooker Hood:Isolate supply as necessary and carry out

service to any type of domestic cooker ventilation hood, clean throughout including all filters, replacing filters and provision of other minor parts as necessary, reconnect, test and leave in working order and remove waste and debris.

Domestic Type Electric Laundry Equipment 882121 R WASHING MACHINE:RENEW NO 301.36 Washing Machine:Isolate supply, disconnect existing, clear away,

supply and install new domestic type electric washing machine, reconnect electric supply, water supply and waste pipework, electrical test, make good on completion and leave in working order and remove waste and debris.

882123 R TUMBLE DRYER:RENEW NO 243.06 Tumble Dryer:Isolate supply, disconnect existing, clear away,

supply and install new domestic type electric tumble dryer, reconnect electric supply, electrical test, make good on completion and leave in working order and remove waste and debris.

Domestic Type Electric Refrigerator 882221 R REFRIGERATOR:RENEW NE 150 LITRE NO 206.76 Refrigerator:Disconnect existing, clear away, supply and install new

ne 150 litre domestic type electric refrigerator complete, reconnect and leave in working order and remove waste and debris.

Page 276: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

242 Local Space Housing

882223 R REFRIGERATOR:RENEW NE 200 LITRE NO 270.56 Refrigerator:Disconnect existing, clear away, supply and install new

over 150 and ne 200 litre domestic type electric refrigerator complete, reconnect and leave in working order and remove waste and debris.

882225 R REFRIGERATOR:RENEW NE 300 LITRE NO 402.56 Refrigerator:Disconnect existing, clear away, supply and install new

over 200 and ne 300 litre domestic type electric refrigerator complete, reconnect and leave in working order and remove waste and debris.

882231 R REFRIGERATOR:RENEW FREEZE DOOR NO 39.03 Refrigerator:Renew freeze food compartment door to domestic type

electric refrigerator and remove waste and debris.

882232 R REFRIGERATOR:RENEW GLASS SHELF NO 24.91 Refrigerator:Renew glass shelf to domestic type electric refrigerator

and remove waste and debris.

882233 R REFRIGERATOR:RENEW WIRE SHELF NO 22.81 Refrigerator:Renew wire shelf to domestic type electric refrigerator

and remove waste and debris.

882234 R REFRIGERATOR:RENEW DRIP SHELF NO 49.03 Refrigerator:Renew drip shelf to domestic type electric refrigerator

and remove waste and debris.

882235 R REFRIGERATOR:RENEW BUTTER TRAY FLAP NO 21.94 Refrigerator:Renew butter tray flap to domestic type electric

refrigerator and remove waste and debris.

882236 R REFRIGERATOR:RENEW SALAD BOX/TRAY NO 31.21 Refrigerator:Renew salad box/tray to domestic type electric

refrigerator and remove waste and debris.

882237 R REFRIGERATOR:RENEW BOTTLE RAIL NO 20.77 Refrigerator:Renew bottle rail to domestic type electric refrigerator

and remove waste and debris.

882238 R REFRIGERATOR:RENEW DOOR INSERT NO 22.51 Refrigerator:Renew plastic door insert complete to domestic type

electric refrigerator and remove waste and debris.

Domestic Type Electric Deep Freeze 882321 R DEEP FREEZE:RENEW 200 LITRE NO 311.26 Deep Freeze:Disconnect existing, clear away, supply and install new

ne 200 litre domestic type electric deep freeze complete, reconnect and leave in working order and remove waste and debris.

882323 R DEEP FREEZE:RENEW 350 LITRE NO 371.76 Deep Freeze:Disconnect existing, clear away, supply and install new

over 200 and ne 350 litre domestic type electric deep freeze complete, reconnect and leave in working order and remove waste and debris.

Page 277: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

243 Local Space Housing

Domestic Type Electrical Equipment - Annual Testing 882411 R DOMESTIC APPLIANCE:ANNUAL TEST NO 11.35 Domestic Appliance:Annual electrical testing, certification and

labelling of domestic type applicances including cookers, hob units, microwaves, washing machines, tumble dryers, refrigerators and deep freezes supplied by Client (to be claimed for each item tested and certified).

Domestic Type Electrical Equipment - Response Call-Outs 882503 R DOMESTIC APPLIANCE:RESPONSE CALL-OUT IT 19.87 Domestic Appliance:Response call-out to any type of domestic

electrical cooker, hob unit, refrigerator, deep freeze, washing machine, tumble dryer supplied by the Client, locate fault, including any necessary testing and report to Client Representative.

882505 R DOMESTIC APPLIANCE:RESPONSE AND REPAIR NE £35.00 IT 84.78 Domestic Applicance:Response call-out to any type of domestic

electrical cooker, hob unit, refrigerator deep freeze, washing machine, tumble dryer supplied by Client, locate fault, including any necessary testing and report to Client Representative, carry out minor renewals or repairs or remedial works to remedy fault including all necessary labour, plant and materials (materials cost allowance £35.00) test operation of equipment on completion, and remove waste and debris.

882507 R DOMESTIC APPLIANCE:RESPONSE AND REPAIR UPTO £85.00 IT 174.26 Domestic Applicance:Response call-out to any type of domestic

electrical cooker, hob unit, refrigerator deep freeze, washing machine, tumble dryer supplied by Client, locate fault, including any necessary testing and report to Client Representative, carry out minor renewals or repairs or remedial works to remedy fault including all necessary labour, plant and materials (materials cost allowance over £35.00 and ne£85.00) test operation of equipment on completion, and remove waste and debris.

Domestic Appliances Generally 842001 R APPLIANCE:DISCONNECT AND RECONNECT NO 11.35 Appliance:Isolate supply, disconnect, set aside, reposition any type

of electric domestic appliance (excluding cookers), remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good all disturbed.

Waste Disposal Unit 872523 R WASTE DISPOSAL:RESPONSE AND REPAIR NO 89.86 Waste Disposal:Responsive call-out to waste disposal unit repair,

carry out minor repair work to rectify fault including all necessary labour, plant, material, disconnect, clear obstruction, ease etc., (material cost allowance £15.00) test operation of waste disposal unit on completion and report to Client Representative and remove waste and debris.

Page 278: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

244 Local Space Housing

Ventilation Fans - Ventilating 840001 R FAN:RENEW MINIMUM 60LTR PER SECOND NO 103.67 Fan:Isolate supply, disconnect, clear away and renew window/wall

mounted plastic cased fan, single speed motor class 1, earthed, integral back draught shutter with trickle ventilation control facility, cord operated, plastic pipe duct extension, external wall grille, fan capable of handling min 60 litre/second and trickle ventilator with total area of 4000mm2, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good all finishes, and remove waste and debris.

840003 R FAN:RENEW BUILT IN WALL FAN NO 106.45 Fan:Isolate supply, disconnect, clear away and renew built in wall

fan, plastic cased, single speed motor class 1, earthed, integral back draught shutter with trickle ventilation control facility, electrically operated, external wall grille, inner grille size 289x273mm fan capable of handling min 60 litre/second and trickle vent with total area of 4000mm2, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good all finishes, and remove waste and debris.

840005 R FAN:RENEW 2 SPEED WALL OR DUCT FAN NO 180.65 Fan:Isolate supply, disconnect, clear away and renew with plastic

cased through-wall or ducted fan with two speed motor class 2, double insulated, air operated automatic back draught shutter with fan capable of handling 76 litre/second at high speed and 38 litre/ second at low speed, provide wall grille if necessary, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good all finishes, and remove waste and debris.

840007 R FAN:RENEW SINGLE SPEED WALL OR DUCT FAN NO 105.78 Fan:Isolate supply, disconnect, clear away and renew with plastic

cased through-wall or ducted fan with single speed motor class 2, double insulated complete with integral back draught automatic shutter, fan capable of handling min 26 litre/second, provide wall grille if necessary, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good all finishes, and remove waste and debris.

840009 R FAN:RENEW IN LINE DUCT FAN NO 129.21 Fan:Isolate supply, disconnect, clear away and renew built in, in

line duct fan comprising single speed motor class 1 earthed, fan capable of handling minimum 60 litre/second, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good all finishes, and remove waste and debris.

840011 R FAN:RENEW CEILING OR DUCT FAN NO 144.15 Fan:Isolate supply, disconnect, clear away and renew ceiling or

ceiling duct fan complete with single speed motor class 1, earthed, integral air operated back draught shutter with fan capable of handling ne 81 litre/second, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good all finishes, and remove waste and debris.

Page 279: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

245 Local Space Housing

840013 R FAN:RENEW FIRE DAMP CEILING OR DUCT FAN NO 143.69 Fan:Isolate supply, disconnect, clear away and renew ceiling or

ceiling duct fan complete with opposed blade fire dampers, single speed motor class 1, earthed, back draught shutter with fan capable of handling ne 81 litre/second, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good all finishes, and remove waste and debris.

840015 R FAN:RENEW TOILET OR BATHROOM FAN NO 59.78 Fan:Isolate supply, disconnect, clear away and renew toilet or

bathroom fan complete with single speed motor class 2, double insulated, integral timer, back draught shutter if required with fan capable of handling 25 litre/second, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good all finishes, and remove waste and debris.

840017 U FAN:RENEW CIRCUIT AND OUTLET NO 88.60 Fan:Isolate supply, strip out, clear away and renew fan spur with cable

run in mini-trunking or rigid PVC conduit chased into wall etc., including fitting of 20 amp fused spur oulet and reconnection of existing fan flex, reconnect electricity supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

840019 U FAN:RENEW FLEX CONNECTION NO 18.21 Fan:Isolate supply, strip out, clear away and renew 1.00m length of

2.5mm 3 core butyl rubber flex to fan and make all necessary connections to 20 amp fused spur outlet and fan, reconnect electricity supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

840031 R FAN:INSTALL WALL FAN NO 114.97 Fan:Install 150mm wall mounted extractor fan with humidistat, install

electrical circuit with fused spur outlet and external shutter, connect, test and adjust settings, including cutting out through wall provision of sleeve and terminal, undertake electrical tests and making good wall and finishes, and remove waste and debris.

Fans - Condensation Control 841001 R FAN:RENEW 2 SPEED CONDENSATION CONTROL NO 153.07 Fan:Isolate supply, disconnect, clear away and renew with plastic

cased through-wall or ducted condensation control fan with 2 speed motor, class 2 double insulated, back draught shutter with fan capable of handling 61 litre/second at high speed and 41 litre/second at low speed, provide wall grille if necessary, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good all finishes, and remove waste and debris.

841003 R FAN:RENEW VARIABLE SPEED CONDENSATION CONTROL NO 165.60 Fan:Isolate supply, disconnect, clear away and renew with plastic

cased through-wall or ducted condensation control fan with variable speed motor class 2 double insulated, back draught shutter, capable of handling 14-22 litre/second at variable speed, 26 litre/second man. boost, provide wall grille necessary, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good all finishes, and remove waste and debris.

Page 280: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

246 Local Space Housing

841005 R FAN:RENEW VARIABLE SPEED TIMER NO 179.71 Fan:Isolate supply, disconnect, clear away and renew with plastic

cased through-wall or ducted condensation control fan with variable speed motor and timer, class 2 double insulated, back draught shutter, fan capable of handling 14-22 litre/second at variable speed, 26 litre/second man. boost, provide wall grille if necessary, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good all finishes, and remove waste and debris.

841007 R FAN:OVERHAUL DOMESTIC EXTRACT NO 21.38 Fan:Overhaul any kind of domestic extractor fan, dismantle and

reassemble, clean and oil, test and leave in working order and remove waste and debris.

841009 R FAN:RENEW WITH LOW VOLTAGE TRANSFORMER TYPE NO 118.80 Fan:Isolate supply, disconnect, clear away and renew with plastic cased

through-wall or ducted low voltage transformer condensation control fan, class 2 double insulated, back draught shutter, provide wall grille if necessary, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good all finishes, and remove waste and debris.

841011 R FAN:INSTALL LOW VOLTAGE TRANSFORMER TYPE NO 127.32 Fan:Install plastic cased through-wall or ducted low voltage transformer

condensation control fan, class 2 double insulated, back draught shutter, install electrical circuit with fused spur outlet and external shutter, connect, test and adjust settings including cutting out through wall provision of sleeve and terminal and making good wall and finishes, provide wall grille if necessary, remake all necessary connections, undertake electrical tests and make good all finishes, and remove waste and debris.

841013 R FAN:INSTALL 2 SPEED CONDENSATION CONTROL NO 161.59 Fan:Install plastic cased through-wall or ducted condensation control fan

with 2 speed motor, class 2 double insulated, back draught shutter with fan capable of handling 61 litre/second at high speed and 41 litre/second at low speed, install electrical circuit with fused spur outlet and external shutter, connect, test and adjust settings including cutting out through wall provision of sleeve and terminal and making good wall and finishes, provide wall grille if necessary, remake all necessary connections, undertake electrical tests and make good all finishes, and remove waste and debris.

Low Energy Positive Output, Whole House Ventilation 841101 R VENT UNIT:INSTALL DRIMASTER 5 IT 454.98 Vent Unit:Install Home Ventilation Ltd’s Drimaster 5 ventilation unit

or other equal and approved in loft space of dwelling, cut or form opening for diffuser in ceiling, supplied complete with ducting, diffuser and filters, unit to be screwed to and including battens spanning across and screwed to joists, connect unit to and including DP switched fuse spur, isolate supply, connect to existing ring main with cable run in mini trunking or rigid PVC conduit, reconnect electricity supply, adjust setting, undertake electrical tests and make good on completion, and remove waste and debris.

Page 281: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

247 Local Space Housing

841103 R VENT UNIT:INSTALL FLATMASTER 5 IT 522.18 Vent Unit:Install Home Ventilation Ltd’s Flatmaster 5 ventilation

system or other equal and approved, cut or form opening in external cavity wall for input grille, cut or form opening in internal wall for discharge grille, install unit, grilles, 100mm ducting, unit plugged and screwed to wall, connect unit to and including DP switched fuse spur, isolate supply, connect to existing ring main with cable run in mini run in mini trunking or rigid PVC conduit, reconnect electricity supply, adjust setting, undertake electrical tests and make good on completion, and remove waste and debris.

841105 R VENT UNIT:OVERHAUL IT 35.51 Vent Unit:Overhaul ventilation unit, clean out, renew filters as

necessary, and remove waste and debris.

General Lighting and Power (Small Scale) Conduit - PVC 850503 R CONDUIT:INSTALL NE 25MM PVC MAKE GOOD LM 6.55 Conduit:Supply and fix ne 25mm round heavy gauge rigid PVC

conduit including all necessary fitting, clipping with saddles at 1200mm centres to any surfaces, and make good on completion, and remove waste and debris.

Conduit - Galvanised Steel 851003 R CONDUIT:INSTALL NE 25MM STEEL MAKE GOOD LM 7.07 Conduit:Supply and fix ne 25mm diameter heavy gauge galvanised

steel conduit including all necessary fittings and fixing with galvanised steel spacer saddles at 1200mm centres to any surface, and make good on completion, and remove waste and debris.

Cable - Drawn In Conduits 851505 R CABLE:DRAW UPTO 6MM SINGLE CABLE LM 2.35 Cable:Supply and draw upto 6.00mm PVC single cable wire through

new conduit or existing conduit, make all necessary connections, and make good on completion, and remove waste and debris.

851507 R CABLE:DRAW 10MM SINGLE CABLE LM 2.77 Cable:Supply and draw 10.00mm PVC single cable wire through

new conduit, or existing conduit, make all necessary connections, and make good on completion, and remove waste and debris.

851509 R CABLE:DRAW 16MM SINGLE CABLE LM 3.61 Cable:Supply and draw 16.0mm PVC single cable wire through new

conduit or existing conduit, make all necessary connections, and make good on completion, and remove waste and debris.

851513 R CABLE:DRAW 1.5MM OR 2.5MM PVC FLAT T AND E LM 2.71 Cable:Supply and draw 1.50mm or 2.50mm PVC flat T and E cable

through new conduit or existing conduit, make all necessary connections, and make good on completion, and remove waste and debris.

851515 R CABLE:DRAW 6MM PVC FLAT T AND E LM 4.02 Cable:Suply and draw 6.00mm PVC flat T and E cable through new

conduit or existing conduit, make all necessary connections, and make good on completion, and remove waste and debris.

Page 282: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

248 Local Space Housing

Cable - Clipped to Backgrounds 852003 R CABLE:INSTALL 1.5MM OR 2.5MM CABLE LM 2.61 Cable:Supply and fix 1.50mm or 2.50mm PVC single cable wire

clipped to wall or soffits, laid in floor or roof space, make all necessary connections, and make good on completion, and remove waste and debris.

852005 R CABLE:INSTALL 6MM CABLE LM 3.59 Cable:Supply and fix 6.00mm PVC single cable wire clipped to wall

or soffit, laid in floor or roof space, make all necessary connections and make good on completion, and remove waste and debris.

852007 R CABLE:INSTALL 10MM CABLE LM 4.58 Cable:Supply and fix 10.00mm PVC single cable wire clipped to wall

or soffits, laid in floor or roof space, make all necessary connections and make good on completion, and remove waste and debris.

852009 R CABLE:INSTALL 16MM CABLE LM 5.42 Cable:Supply and fix 16.00mm PVC single cable wire clipped to wall

or soffits, laid in floor or roof space, make all necessary connections and make good on completion, and remove waste and debris.

852013 R CABLE:INSTALL 1.5MM OR 2.5MM T AND E LM 3.38 Cable:Supply and fix 1.50mm or 2.50mm PVC flat T and E cable

clipped to wall or soffits, laid in floor or roof space, make all necessary connections, and make good on completion, and remove waste and debris.

852015 R CABLE:INSTALL 6MM T AND E LM 4.17 Cable:Supply and fix 6.00mm PVC flat T and E cable clipped to wall

or soffits, laid in floor or roof space, make all necessary connections, and make good on completion, and remove waste and debris.

852017 R CABLE:INSTALL 10MM T AND E LM 5.60 Cable:Supply and fix 10.00mm PVC flat T and cable clipped to wall

or soffits, laid in floor or roof space, make all necessary connections, and make good on completion, and remove waste and debris.

Cable and Conduit Chased into Background 852509 R CABLE:FIX 1.5MM OR 2.5MM T AND E AND CONDUIT LM 15.53 Cable:Supply and fix 1.50mm or 2.50mm PVC flat T and E cable

drawn in and including rigid PVC conduit chased into plastered surface, make good plaster, make all necessary connections, and make good on completion, and remove waste and debris.

852511 R CABLE:FIX 6MM T AND E AND CONDUIT LM 17.66 Cable:Supply and fix 6.0mm PVC flat T and E cable drawn in and

including rigid PVC conduit chased into plastered surface, make good plaster, make all necessary connections, and make good on completion, and remove waste and debris.

Page 283: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

249 Local Space Housing

Cable and Mini-Trunking 853009 R CABLE:FIX 1.5MM OR 2.5MM T AND E AND MINI-TRUNKING LM 9.98 Cable:Supply and fix 1.50mm or 2.50mm PVC flat T and E cable

drawn in and including rigid PVC mini-trunking, make all connections, and make good on completion, and remove waste and debris.

853011 R CABLE:FIX 6.0MM T AND E AND MINI-TRUNKING LM 10.73 Cable:Supply and fix 6.0mm PVC flat T and E cable drawn in and

including rigid PVC mini-trunking, make all connections, and make good on completion, and remove waste and debris.

Cables - MICC and MICV 853501 R MICC:INSTALL 2L 1.5MM OR 2.5MM CABLE LM 12.20 MICC:Supply and fix 2L 1.5mm or 2.50mm cable clipped to ceiling

or walls, including all necessary bends and dressings, and make good on completion, and remove waste and debris.

853505 R MICC:TERMINATE 2L 1.5MM OR 2.5MM CABLE NO 16.08 MICC:Terminate 2L 1.50mm or 2.50mm cable, assemble gland to

box, make termination with upto 250mm tail.

Final Circuits Final Circuits - Lighting 854501 R LIGHT:RENEW GROUND FLOOR CIRCUIT 1 WAY NO 70.09 Light:Isolate supply, strip out, clear away and renew one-way

lighting circuit, including installation of mini-trunking or rigid PVC conduit chased into wall etc., switch, pendant or similar to 1 No. ground floor lighting point, reconnect electricity supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

854503 R LIGHT:RENEW GROUND FLOOR CIRCUIT 2 WAY NO 111.04 Light:Isolate supply, strip out, clear away and renew two-way

lighting circuit, including installation of mini-trunking or rigid PVC conduit chased into wall etc., switch, pendant or similar to 1 No. ground floor lighting point, reconnect electricity supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

854505 R LIGHT:RENEW UPPER FLOOR CIRCUIT 1 WAY NO 64.93 Light:Isolate supply, strip out, clear away and renew one-way

lighting circuit, including installation of mini-trunking or rigid PVC conduit chased into wall etc., switch, pendant or similar to 1 No. upper floor lighting point, reconnect electricity supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

854507 R LIGHT:RENEW UPPER FLOOR CIRCUIT 2 WAY NO 101.99 Light:Isolate supply, strip out, clear away and renew two-way

lighting circuit including installation of mini-trunking or rigid PVC conduit making all necessary chasing into wall etc., switched pendant or similar to 1 No. upper floor lighting point, reconnect electricity supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

Page 284: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

250 Local Space Housing

854709 R LIGHT:RENEW HALL/STAIRWAY CIRCUIT 2 WAY NO 129.28 Light:Isolate supply, strip out, clear away and renew two-way

lighting point to hall/stairway including installation of mini-trunking or rigid PVC conduit, chased into wall etc., switches, pendant or similar, reconnect electricity supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

Final Circuits - Power 855001 R POWER:RENEW RING MAIN GROUND NE 4 NO SOCKETS NO 307.61 Power:Isolate supply, strip out, clear away and renew ring main

circuit to ground floor of dwelling with ne 4 No. 13 amp double socket outlets including install mini-trunking or rigid PVC conduit chased into wall etc., reconnect electricity supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

855003 R POWER:RENEW RING MAIN GROUND 4-8 NO SOCKETS NO 363.62 Power:Isolate supply, strip out, clear away and renew ring main

circuit to ground floor of dwelling with over 4 No. and ne 8 No. 13 amp double socket outlets including install mini-trunking/PVC conduit chased into walls, reconnect electricity supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

855004 R POWER:RENEW RING MAIN GROUND 8-12 NO SOCKETS NO 411.25 Power:Isolate supply, strip out, clear away and renew ring main circuit to

ground floor of dwelling with over 8 No. and ne 12 No. 13 amp double socket outlets including install mini-trunking/PVC conduit chased into walls, reconnect electricity supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

855005 R POWER:RENEW UPPER RING MAIN NE 4 NO SOCKETS NO 279.30 Power:Isolate supply, strip out, clear away and renew ring main

circuit to upper floor of dwelling including installation of mini-trunking or rigid PVC conduit chased into wall etc., with ne 4 No. 13 amp double socket outlets, reconnect electric supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

855007 R POWER:RENEW UPPER RING MAIN 4-8 NO SOCKETS NO 328.06 Power:Isolate supply, strip out, clear away and renew ring main

circuit to upper floor of dwelling including installation of mini-trunking or rigid PVC conduit chased into wall etc., with over 4 No. ne 8 No. 13 amp double socket outlets, reconnect electricity supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

855008 R POWER:RENEW UPPER RING MAIN 8-12 NO SOCKETS NO 393.04 Power:Isolate supply, strip out, clear away and renew ring main circuit to

upper floor of dwelling including installation of mini-trunking or rigid PVC conduit chased into wall etc., with over 8 No. ne 12 No. 13 amp double socket outlets, reconnect electricity supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

Page 285: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

251 Local Space Housing

855009 R POWER:RENEW SPUR OUTLET GROUND FLOOR NE 10M NO 90.31 Power:Isolate supply, strip out, clear away and renew 13 amp spur

outlet to ground floor, connect to existing ring main, with cable run in mini-trunking or rigid PVC conduit chased into wall ne 10.00m, make all necessary connections, reconnect electricity supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

855010 R POWER:NEW SPUR OUTLET GROUND FLOOR NE 10M NO 102.85 Power:Isolate supply, provide new 13 amp spur single socket outlet

to ground floor, connect to existing ring main with cable run in mini- trunking or rigid PVC conduit chased into wall ne 10.00m, all builders work in connection etc, make all necessary connections, reconnect electricity supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

855011 R POWER:RENEW SPUR OUTLET UPPER FLOOR NE 10M NO 79.97 Power:Isolate supply, strip out, clear away and renew 13 amp spur

outlet to upper floor, connect to existing ring main, with cable run in mini-trunking or rigid PVC conduit chased into wall ne 10m, make all necessary connections, reconnect electricity supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

855012 R POWER:NEW SPUR UPPER FLOOR NE 10M NO 82.98 Power:Isolate supply, provide new 13 amp spur single socket outlet

to upper floor, connect to existing ring main with cable run in mini- trunking or rigid PVC conduit chased into wall ne 10.00m, all builders work in connection etc, make all necessary connections, reconnect electricity supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

855013 R POWER:RENEW SOCKET OUTLET-GROUND FLOOR NO 87.02 Power:Isolate supply, strip out, clear away and renew 13 amp

double socket outlet to ground floor, connect to existing ring main, with cable run in mini-trunking or rigid PVC conduit chased into wall etc, ne 10.00m, make all necessary connections, reconnect electricity supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

855015 R POWER:RENEW SOCKET OUTLET-UPPER FLOOR NO 74.53 Power:Isolate supply, strip out, clear away and renew 13 amp

double socket outlet to upper floor, connect to existing ring main, with cable run in mini-trunking or rigid PVC conduit chased into wall etc, ne 10.00m, make all necessary connections, reconnect electricity supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

855017 R POWER:RENEW BOILER OUTLET GROUND NE 10M NO 77.25 Power:Isolate supply, strip out, clear away and renew 13 amp fused

switched spur outlet to ground floor, connect to existing ring main, with cable run in mini-trunking or rigid PVC conduit chased into wall ne 10.00m, make all necessary connections, reconnect electricity supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

Page 286: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

252 Local Space Housing

855019 R POWER:NEW BOILER OUTLET GROUND NE 10M NO 84.11 Power:Isolate supply, provide new 13 amp fused switch spur outlet to

ground floor, connect to existing ring main with cable run in mini- trunking or rigid PVC conduit chased into wall ne 10.00m, all builders work in connection etc, make all necessary connections, reconnect electricity supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

Consumer Control Units 855502 U CCU:RENEW NE 6 WAY MOULDED UNIT NO 150.07 CCU:Isolate supply, disconnect, clear away and renew any ne six-

way moulded consumer control unit with MCB’s, RCD protection, 100 amp double pole switch, blank covers on spare ways, remove old unit, fix new unit, make all necessary connections to existing cables, reconnect electricity supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

855503 U CCU:RENEW 7 TO 12 WAY MOULDED UNIT NO 193.24 CCU:Isolate supply, disconnect, clear away and renew any seven to

twelve-way moulded consumer control unit with MCB’s, RCD protection, 100 amp double pole switch, blank covers on spare ways, remove old unit, fix new unit, make all necessary connections to existing cables, reconnect electricity supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

855551 U CCU:RENEW NE 10 WAY MOULDED SPLIT LOAD UNIT NO 169.94 CCU:Isolate supply, disconnect, clear away and renew any type

consumer control unit with ne ten-way moulded split load consumer control unit with MCB’s, RCD protection, 100 amp double pole switch, blank covers on spare ways, remove old unit, fix new unit, make all necessary connections to existing cables, reconnect electricity supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

855553 U CCU:RENEW 11 TO 14 WAY MOULDED SPLIT LOAD UNIT NO 194.11 CCU:Isolate supply, disconnect, clear away and renew any type

consumer control unit with new eleven to fourteen-way moulded split load consumer control unit with MCB’s, RCD protection, 100 amp double pole switch, blank covers on spare ways, remove old unit, fix new unit, make all necessary connections to existing cables, reconnect electricity supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

855509 U CCU:INSTALL ANY SIZE RCD NEW METER TAILS NO 106.86 CCU:Isolate supply, remove existing mains switch and supply and

fit new any size residual current device to existing consumer unit including new meter tails, reconnect electricity supply, undertake electrical tests, test operation of residual current device and make good on completion, and remove waste and debris.

855510 U CCU:INSTALL NEW METER TAILS IT 26.98 CCU:Isolate supply, install new meter tails not exceeding 1.00m in

lengths, reconnect electricity supply, undertake electrical tests, test operation of residual current device and make good on completion, and remove waste and debris.

Page 287: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

253 Local Space Housing

855511 U CCU:INSTALL ANY SIZE RCD NO 89.33 CCU:Isolate supply and supply and fit any size RCD to existing

consumer unit, reconnect supply, undertake electrical tests and test operation of RCD and make good on completion, and remove waste and debris.

855512 U CCU:INSTALL RCBO/RCD TO BATHROOM CIRCUITS IT 107.03 CCU:Isolate supply and supply and fit any size RCD to existing

consumer unit to protect all circuits to bathroom, reconnect supply, undertake electrical tests, test operation of RCD, make good on completion, and remove waste and debris.

855513 E CCU:RENEW ANY SIZE MCB NO 14.86 CCU:Isolate supply and renew any size mini-circuit breaker, remove

defective or unsuitable mini-circuit breaker, fit new, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

855515 U CCU:RENEW FUSE CARRIER OR SHIELD NO 12.74 CCU:Isolate supply and renew fuse carrier or shield, remove

defective or unsuitable fuse carrier or shield, fit new, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

855521 U CCU:RENEW HRC FUSE NO 18.25 CCU:Isolate supply and renew any HRC fuse, reconnect electricity

supply, undertake electrical tests, and make good on completion, and remove waste and debris.

855525 R CCU:RENEW MOUNTING BOARD NO 72.24 CCU:Isolate supply and disconnect all switchgear and sub-circuits,

liase with Local Electricity Company to disconnect supply, renew and securely fix new backboard, reconnect switch-gear and sub-circuits and modify bonding, reconnect electricity supply, electrical tests, test operation of residual current device, provide certificate, make good on completion, and remove waste and debris.

855527 U CCU:MODIFY BACKBOARD NO 35.51 CCU:Modify backboard to accept new cables, cut hole through brick

or block wall to accommodate new cables, and make good on completion, and remove waste and debris.

Pendants Pendants and Lampholders 856103 R LIGHT:RENEW FLEX LAMPHOLDER ROSE NO 16.23 Light:Isolate supply, disconnect, clear away and renew TRS cord

pendant flex, moulded plastic lampholder with HO skirt and ceiling rose with holding joint ring, reconnect to existing cables, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

856105 R LIGHT:RENEW BATTEN HOLDER NO 11.39 Light:Isolate supply, disconnect, clear away extg. and renew plastic

batten lamp holder, connect to existing cables, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

Page 288: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

254 Local Space Housing

Luminaires - Bulkheads Bulkhead - Fittings 856603 R LIGHT FITTING:RENEW 2X8W BULKHEAD TYPE NO 48.24 Light Fitting:Isolate supply, disconnect, clear away and renew

bulkhead light fitting with metal alloy clad body, polycarbonate light diffuser with screw fittings and twin 300mm 8 watt fluorescent lamps, connect to existing cables, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

856605 R LIGHT FITTING:RENEW RAMPART LIGHT-70 W TYPE NO 118.43 Light Fitting:Isolate supply, disconnect, clear away and renew rampart

light fitting, with metal alloy body borosilicate glass prismatic front cover and with guard complete with 70 watt sodium vapour lamp, connect to existing cables, reconnect electricity supply, and undertake electrical test and make good on completion, and remove waste and debris.

856607 R LIGHT FITTING:RENEW 1000W SECURITY TYPE NO 33.19 Light Fitting:Isolate supply, disconnect, clear away and renew 1000

watt amenity light fitting with metal alloy body, borosilicate glass prismatic front cover and wire guard, complete with ne 1000 watt halogen lamp, connect to existing cables, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

856609 R LIGHT FITTING:RENEW 16W LV BULKHEAD TYPE NO 45.29 Light Fitting:Isolate supply, disconnect, clear away and renew

bulkhead light fitting with metal alloy clad body, polycarbonate diffuser with screw fitting and 16 watt 2D lamp, connect to existing cables, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

856611 R LIGHT FITTING:RENEW 28W LV BULKHEAD TYPE NO 54.73 Light Fitting:Isolate supply, disconnect, clear away and renew

bulkhead light fitting with metal alloy clad body, polycarbonate diffuser with screw fitting and 28 watt 2D lamp, connect to existing cables, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

856613 R LIGHT FITTING:REMOVE AND REFIX ANY TYPE NO 20.09 Light Fitting:Isolate supply, remove and securely refix and

reconnect any type of communal or external light fitting including all tests and make good on completion, and remove waste and debris.

856615 R BATHROOM LIGHT FITTING:RENEW WITH SEALED UNIT NO 45.54 Bathroom Light Fitting:Isolate supply, disconnect, clear away and renew

existing with or install sealed bathroom light fittingcomplete with lamp and diffuser, connect to existing cables, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

Bulkhead - Lamps 857001 R LAMP:RENEW NE 100W BULKHEAD LAMP NO 3.58 Lamp:Take off, clear away and renew ne 100 watt RS tungsten

lamp to light fitting including remove and refix cover, and remove waste and debris.

Page 289: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

255 Local Space Housing

857003 R LAMP:RENEW 8 WATT BULKHEAD LAMP NO 6.53 Lamp:Take off, clear away and renew 8 watt fluorescent lamp to

bulkhead fitting including remove and refix cover, and remove waste and debris.

857006 R LAMP:RENEW 150W HALOGEN LAMP NO 5.94 Lamp:Take off, clear away and renew 150 watt tungsten halogen

lamp to security light, and remove waste and debris.

857005 R LAMP:RENEW 500W HALOGEN LAMP NO 6.16 Lamp:Take off, clear away and renew 500 watt tungsten halogen

lamp to security light, and remove waste and debris.

857007 R LAMP:RENEW 1000W HALOGEN LAMP NO 9.39 Lamp:Take off, clear away and renew 1000 watt tungsten halogen

lamp to security light, and remove waste and debris.

857015 R LAMP:RENEW 70W SON-T LAMP. NO 13.76 Lamp:Take off, clear away and renew 70 watt Son -T Thorn lamp to

amenity light, and remove waste and debris.

857017 R LAMP:RENEW 16 WATT 2D LAMP NO 8.51 Lamp:Take off, clear away and renew 16 watt 2D lamp to bulkhead

fitting including remove and refix cover, and remove waste and debris.

857019 R LAMP:RENEW 28 WATT 2D LAMP NO 12.55 Lamp:Take off, clear away and renew 28 watt 2D lamp to bulkhead

fitting including remove and refix cover, and remove waste and debris.

Bulkhead - Diffuser 857501 R LIGHT FITTING:RENEW BULKHEAD DIFFUSER NO 14.08 Light Fitting:Disconnect, clear away and renew polycarbonate light

diffuser with screw fittings to bulkhead fitting, and remove waste and debris.

Luminaires - Fluorescent Lights Fluorescent - Fittings 858101 R LIGHT FITTING:RENEW SINGLE FLUORESCENT WITH TUBE NO 26.40 Light Fitting:Isolate supply, take down clear away and renew any

size fluorescent single tube fitting, including tube, connect to existing cables, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

858103 R LIGHT FITTING:RENEW DOUBLE FLUORESCENT WITH TUBES NO 45.06 Light Fitting:Isolate supply, take down, clear away and renew any

size fluorescent double tube fitting including tubes, connect to existing cables, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

858107 R LIGHT FITTING:REMOVE REFIX ANY FLUORESCENT FITTING TYPE NO 10.26 Light Fitting:Isolate supply, remove and securely refix and

reconnect any light fitting including all tests and make good on completion, and remove waste and debris.

Page 290: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

256 Local Space Housing

858111 R LIGHT FITTING:OVERHAUL FLUORESCENT ANY TYPE IT 14.98 Light Fitting:Overhaul any type of fluorescent fitting and carry out

minor repairs including renewing starter as necessary, and remove waste and debris.

Fluorescent - Diffusers 858301 R LIGHT FITTING:RENEW SINGLE FLUORESCENT DIFFUSER NO 19.36 Light Fitting:Take down, clear away and renew diffuser to any

single tube fluorescent fitting, and remove waste and debris.

858303 R LIGHT FITTING:RENEW DOUBLE FLUORESCENT DIFFUSER NO 20.27 Light Fitting:Take down, clear away and renew diffuser to any

double tube fluorescent fitting, and remove waste and debris.

Fluorescent - Tubes 858501 R LIGHT FITTING:RENEW ANY SIZE FLUORESCENT TUBE NO 5.11 Light Fitting:Take down, clear away, and renew any size fluorescent

tube, and remove waste and debris.

Low Energy Lamps 858701 R LAMP:RENEW WITH PL LOW ENERGY NO 5.39 Lamp:Renew or supply and fix new PL low energy lamp to existing

light fitting, and remove waste and debris.

858703 R LAMP:RENEW WITH SL LOW ENERGY NO 18.42 Lamp:Renew or supply and fix new SL low energy lamp to existing

light fitting, and remove waste and debris.

858705 R LAMP:RENEW WITH PLCE TO BULKHEAD NO 9.50 Lamp:Renew or supply and fix new PLCE low energy lamp to

existing bulkhead light fitting, and remove waste and debris.

Accessories Accessories - Generally 860501 R SWITCH OR OUTLET:REMOVE AND REFIX NO 10.37 Switch or Outlet:Isolate supply, remove any type of switch, outlet

and the like including any box, securely refix loose box, prepare cable ends and make all necessary connections and refix switch/outlet etc., reconnect electric supply, undertake electrical tests and make good on completion, and remove waste and debris.

860503 R SWITCH OR OUTLET:FIX BLANK PLATE NO 10.68 Switch or Outlet:Isolate supply and remove any switch outlet etc.,

terminate cable ends and supply and fix plastic blank plate cover to switch/outlet box reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

860505 R SWITCH OR OUTLET:DRY LINING BOX NO 18.09 Switch or Outlet:Isolate supply, remove and set aside disconnect,

clear away and renew plastic single or double flush box to suit dry lining installations, remove and refit plate, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

Page 291: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

257 Local Space Housing

860507 E SWITCH OR OUTLET:SECURE LOOSE NO 2.56 Switch or Outlet:Secure any loose switch or socket outlet plate or

the like including provision of new screws if necessary, and remove waste and debris.

Accessories - Light Switches 861001 R SWITCH:RENEW FLUSH BOX NO 17.63 Switch:Isolate supply, remove and set aside plate disconnect, clear

away and renew galvanised steel or plastic single or double flush box, plug to wall as necessary, refit plate, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

861003 R SWITCH:RENEW SURFACE BOX NO 9.41 Switch:Isolate supply, disconnect, clear away and renew any plastic

surface mounted box, plug wall as necessary, make all necessary connections reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

861005 R SWITCH:RENEW 5 AMP NE 3 GANG PLATE NO 9.47 Switch:Isolate supply, disconnect, clear away and renew 5 amp ne

3 gang single pole moulded plastic plate switch, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

861007 R SWITCH:RENEW 5AMP NE 3 GANG 2 WAY PLATE NO 14.10 Switch:Isolate supply, disconnect, clear away and renew 5 amp ne

3 gang, 2 way single pole moulded plastic plate switch, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

861009 R SWITCH:RENEW 5AMP NE 3 GANG PLATE AND BOX NO 19.25 Switch:Isolate supply, disconnect, clear away and renew 5 amp ne

3-gang single pole moulded plastic plate switch and galvanised steel or plastic plaster depth box, plug wall as necessary, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

861011 R SWITCH:RENEW 5AMP NE 3 GANG 2 WAY PLATE AND BOX NO 23.55 Switch:Isolate supply, disconnect, clear away and renew 5 amp ne

3 gang, 2 way single pole moulded plastic plate switch and galvanised steel or plastic plaster depth, box, plug wall as necessary, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

861013 R SWITCH:RENEW CEILING PULL SWITCH NO 16.59 Switch:Isolate supply, disconnect, clear away and renew 5 amp

one-way or two-way single pole surface pattern moulded plastic ceiling pull switch with matching break joint ring and make all necessary connections to existing cables, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

861015 R SWITCH:RENEW PULL SWITCH CORD NO 6.58 Switch:Renew pull switch cord only.

Page 292: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

258 Local Space Housing

Accessories - Socket Outlets 861501 R SOCKET:RENEW FLUSH BOX NO 17.63 Socket:Isolate supply, remove and set aside plate disconnect, clear

away and renew galvanised steel or plastic single or double flush box, plug to wall as necessary, refit plate, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

861503 R SOCKET:RENEW SURFACE BOX NO 10.27 Socket:Isolate supply, remove and set aside plate, disconnect, clear

away and renew plastic single or double surface mounted box, plug to wall necessary, refix plate, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

861505 R SOCKET:RENEW 13A SINGLE PLATE NO 10.74 Socket:Isolate supply, disconnect, clear away and renew 13 amp

single moulded plastic switch socket outlet plate, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

861507 R SOCKET:RENEW 13A DOUBLE PLATE NO 11.87 Socket:Isolate supply, disconnect, clear away and renew 13 amp

double moulded plastic switch socket outlet plate, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

861509 R SOCKET:RENEW SINGLE OUTLET PLATE AND BOX NO 20.51 Socket:Isolate supply, disconnect, clear away and renew 13 amp

single moulded plastic switch socket outlet and galvanised steel flush box, including plugging to walls as necessary, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

861511 R SOCKET:RENEW DOUBLE OUTLET PLATE AND BOX NO 30.16 Socket:Isolate supply, disconnect, clear away and renew 13 amp

double moulded plastic switch socket outlet and galvanised steel flush box including plugging walls as necessary, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

861513 R SOCKET:RENEW 13A RCD OUTLET NO 73.69 Socket:Isolate supply, disconnect, clear away and renew 13 amp

single moulded plastic switch socket outlet, integral RCD, 30mA sensitivity, and galvanised steel flush box, plug walls as necessary, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

861515 R SOCKET:SINGLE SURFACE OUTLET PLATE AND BOX NO 20.24 Socket:Supply and fix 13 amp single moulded plastic switch socket

outlet and moulded plastic surface mounted box, including plugging to walls as necessary, make all necessary connections to cables, undertake electrical tests and make good on completion, and remove waste and debris.

Page 293: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

259 Local Space Housing

861517 R SOCKET:INSTALL 13A DOUBLE OUTLET PLATE AND BOX NO 30.74 Socket:Supply and fix 13 amp double moulded plastic switch socket

outlet and moulded plastic surface mounted box, including plugging to walls as necessary, make all necessary connections to cables, undertake electrical tests and make good on completion, and remove waste and debris.

Accessories - DP Switches 862001 R SWITCH:RENEW 20A DP SWITCH NO 22.21 Switch:Isolate supply, disconnect, clear away and renew 20 amp

moulded plastic double pole switch and moulded plastic mounting box, including plugging to walls as necessary, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

862003 R SWITCH:RENEW 20A DP CEILING SWITCH NO 28.79 Switch:Isolate supply, disconnect, clear away and renew 20 amp

moulded plastic double pole ceiling pull cord switch complete with neon indicator, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

862005 R SOCKET:RENEW 13A DP PLATE WITH OUTLET NO 15.50 Socket:Isolate supply, disconnect, clear away and renew 13 amp

moulded plastic double pole fused switch plate with outlet, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

862007 R SOCKET:RENEW 13A DP PLATE WITH INDICATOR NO 19.53 Socket:Isolate supply, disconnect, clear away and renew 13 amp

moulded plastic double pole fused switch plate with outlet and neon indicator, remake all necessary connections, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

Shaver Points 863001 R SHAVER:RENEW SHAVER SUPPLY UNIT NO 37.50 Shaver:Isolate supply, disconnect, clear away and renew dual-

voltage output shaver supply unit, reconnect electricity supply, undertake electrical tests and make good on completion, and remove waste and debris.

863003 R SHAVER LIGHT:INSTALL COMPLETE NO 91.43 Shaver Light:Isolate supply and install approved shaver point

incorporating strip light including cut out and make good for all concealed conduit and wiring, make all connections, reconnect, electrical tests and make good on completion, and remove waste and debris.

863005 R SHAVER LIGHT:RENEW COMPLETE NO 44.39 Shaver Light:Isolate supply and renew approved shaver point

incorporating strip light including make all connections, reconnect, electrical tests and make good on completion, and remove waste and debris.

863007 R LAMP:RENEW SHAVER LAMP NO 4.77 Lamp:Take off cover and renew lamp to any type of shaver light

fitting and refix cover, and remove waste and debris..

Page 294: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

260 Local Space Housing

Special Installations Door Bell Installation 870501 R CABLE:INSTALL BELL WIRE LM 2.66 Cable:Supply and fix 0.5mm PVC twin bell wire clipped to wall or

soffit and make all necessary connections to bells, bell units, transformers and bell push and make good on completion, and remove waste and debris.

870503 R DOOR BELL:RENEW UNDERDOME COMPLETE NO 17.35 Door Bell:Disconnect, clear away and renew 3-4-8v AC supply

underdome bell complete screwed to timber, make all necessary connections, make good and leave in working order and remove waste and debris.

870505 R DOOR BELL:RENEW TRANSFORMER NO 27.91 Door Bell:Disconnect, clear away and renew transformer 220/240v

AC primary supply 3-4-8v secondary output complete, screwed to timber, make all necessary connections, undertake electrical tests and make good on completion, and remove waste and debris.

870507 R DOOR BELL:RENEW BELL PUSH NO 10.74 Door Bell:Disconnect, clear away and renew 1 amp bell push,

screwed to timber, make all necessary connections, undertake electrical tests and make good on completion, and remove waste and debris.

870509 R DOOR BELL:OVERHAUL REPAIR RELOCATE NO 11.72 Door Bell:Overhaul and repair any type of faulty door bell,

disconnect supply and later reconnect, relocate where instructed by Client Representative, make all necessary adjustments, test and leave in working order on completion, make good as necessary, and remove waste and debris.

870511 R DOOR BELL:RENEW BATTERY TYPE NO 27.10 Door Bell:Renew battery operated door bell or chime of any type,

complete with batteries, to match existing, fixing to any background and connection to bell push wire, remove existing fitting, test, make good and leave in working order and remove waste and debris.

870513 R DOOR BELL:RENEW WIRELESS TYPE NO 59.69 Door Bell:Renew battery operated wireless controlled door bell of any

type, complete with batteries, to match existing, fixing to any background, remove existing fitting, test, make good and leave in working order and remove waste and debris.

Door Entry Installation 871003 R DOOR ENTRY:RENEW INTERCOM KIT NO 126.54 Door Entry:Disconnect, clear away and renew intercom kit

complete, make all necessary connections, leave in working order on completion, and remove waste and debris.

871007 R DOOR ENTRY:INSTALL EXTRA PHONE NO 48.80 Door Entry:Supply and install extra door phone complete, make all

connections, leave in working order on completion, and remove waste and debris.

Page 295: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

261 Local Space Housing

871009 R DOOR ENTRY:RENEW ELECTRIC LATCH NO 37.19 Door Entry:Disconnect, clear away and renew electric door latch

complete, make all necessary connections, leave in working order on completion, and remove waste and debris.

871011 R DOOR ENTRY:RENEW 6 CORE CABLING LM 2.68 Door Entry:Strip out, clear away and renew 6 core cabling to door

entry installation, clipped to wall or soffit, make all necessary connections, test and make good, and remove waste and debris.

Fire Alarm Installations 871101 U FIRE ALARM:RENEW BREAK GLASS UNIT NO 27.47 Fire Alarm:Renew or supply and install break glass unit complete

with hammer and chain, flush or surface mounted, plugged and screwed to structure, including making all connections to existing wiring, test operation and make good on completion, and remove waste and debris.

871103 U FIRE ALARM:RENEW XENON FLASHER NO 49.03 Fire Alarm:Renew or supply and install Xenon flasher 24 volt, with

conduit box plugged and screwed to structure, including making all connections to existing wiring, test operation and make good on completion, and remove waste and debris.

871105 U FIRE ALARM:RENEW 150MM BELL NO 37.86 Fire Alarm:Renew or supply and install 150mm bell unit, with

conduit box plugged and screwed to structure, including making all connections to existing wiring, test operation and make good on completion, and remove waste and debris.

871107 U FIRE ALARM:RENEW 225MM BELL NO 58.69 Fire Alarm:Renew or supply and install 225mm bell unit, with

conduit box plugged and screwed to structure, including making all connections to existing wiring, test operation and make good on completion, and remove waste and debris.

871109 U FIRE ALARM:RENEW BUZZER NO 39.37 Fire Alarm:Renew or supply and install buzzer unit, with conduit

box plugged and screwed to structure, including making all connections to existing wiring, test operation and make good on completion, and remove waste and debris.

871111 U FIRE ALARM:RENEW SIREN NO 62.31 Fire Alarm:Renew or supply and install siren unit, with conduit box

plugged and screwed to structure, including making all connections to existing wiring, test operation and make good on completion, and remove waste and debris.

871113 U FIRE ALARM:RENEW WARBLER NO 67.14 Fire Alarm:Renew or supply and install warbler unit, with conduit

box plugged and screwed to structure, including making all connections to existing wiring, test operation and make good on completion, and remove waste and debris.

871115 U FIRE ALARM:RENEW DOOR RELEASE UNIT NO 93.40 Fire Alarm:Renew or supply and install door release unit, surface or

recessed type, secure to background, including making all connections to existing wiring, test operation and make good on completion, and remove waste and debris.

Page 296: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

262 Local Space Housing

871117 U FIRE ALARM:RENEW 6 ZONES PANEL IT 448.28 Fire Alarm:Renew fire alarm panel upto six zones, isolate supply,

disconnect circuits, remove existing panel, reconnect circuits, test system, include connection to off site warning system, clean up.

871118 U FIRE ALARM:SERVICE ANY TYPE IT 170.30 Fire Alarm:Attend and carry out service to fire alarm installation

complete to block of dwellings or scheme including control panel complete with alarm input and ouput circuits, sounder circuits, detection/activation loops, integral batteries and charger unit, and indicator lights, sound alarm switch, alarms silence switch, reset push button and lamp test, complete with manual call points, automatic detectors and sounders.

Burglar Alarm Installation 871401 U BURGLAR ALARM:SERVICE ANY TYPE IT 170.30 Burglar Alarm:Attend and carry out service to burglar alarm

installation complete to block of dwellings or scheme including control panel complete with alarm input and ouput circuits, sounder circuits detection/activation loops, integral batteries and charger unit, and indicator lights, sound alarm switch, alarms silence switch, reset push button and lamp test, complete with automatic detectors and sounders.

871403 U BURGLAR ALARM:RESET CODES IT 45.41 Burglar Alarm;Attend upon dwelling with burglar alarm, reset codes for

new or existing tenant, test.

TV Aerial Installation 871501 R TV OUTLET:REMOVE, RECONNECT, REFIX NO 5.68 TV Outlet:Take off any type of existing flush or surface mounted

outlet box, remake connections and refix and test, make good on completion, and remove waste and debris.

871503 R TV OUTLET:RENEW FLUSH OR SURFACE BOX NO 13.84 TV Outlet:Take off any type of existing flush or surface mounted

outlet box, supply and fix new remake all connections, test, make good on completion, and remove waste and debris.

871505 R TV AERIAL:REWIRE COAXIAL NE 10M IT 29.17 TV Aerial:Take out existing and or supply and fix new TV coaxial

cabling from existing outlet to aerial in length ne 10.00m, run in existing conduit or surface fixed including remake all joints, test and make good on completion, and remove waste and debris.

871507 R TV AERIAL:REWIRE COAXIAL 10-20M IT 46.99 TV Aerial:Take out existing and or supply and fix new TV coaxial

cabling from existing outlet to aerial in length over 10.00 and ne 20.00m, run in existing conduit or surface fixed including remake all joints and make good on completion, and remove waste and debris.

871509 R TV AERIAL:REWIRE COAXIAL OVER 20M IT 66.83 TV Aerial:Take out existing and or supply and fix new TV coaxial

cabling from existing outlet to aerial in length over 20.00m, run in existing conduit or surface fixed including remake all joints and make good on completion, and remove waste and debris.

Page 297: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

263 Local Space Housing

871513 R TV AERIAL:LOFT INSTALLATION COMPLETE IT 88.22 TV Aerial:Gain access into loft space, provide and install new loft TV

aerial complete with and including TV coaxial cabling ne 10m long to and including new surface mounted box, make all necessary connections and joints, adjust aerial direction, make good, test and leave in working order on completion, and remove waste and debris.

871515 U COMMUNAL TV AERIAL:ATTEND FAULT IT 68.12 Communal TV Aerial:Attend upon scheme, investigate fault in analogue or

digital TV aerial or receiver, remedy fault without renewing any parts or components, test, and remove waste and debris.

CCTV Service 871603 U CCTV:SERVICE ANY TYPE IT 68.12 CCTV:Attend and carry out service to CCTV installation complete to

block of dwellings or scheme including control panel complete with input and output circuits, detection/activation loops, integral batteries and charger unit, and indicator lights, video cameras and monitors etc.

Smoke Detectors 872003 U SMOKE DETECTOR:INSTALL BATTERY OPERATED TYPE NO 18.24 Smoke Detector:Supply and install battery operated smoke detector

including test, make good and leave in working order and remove waste and debris.

872008 U SMOKE DETECTOR:INSTALL MAINS OPTICAL TYPE NO 81.43 Smoke Detector:Isolate, supply and install mains operated optical

smoke detector with rechargeable DC battery or condensor back up self contained type to BS 5446 kitemark certified with hush button including make all necessary connections to supply including junction box, reconnect test and make good on completion, and remove waste and debris.

872010 U SMOKE DETECTOR:INSTALL MAINS IONISATION TYPE NO 74.48 Smoke Detector:Isolate, supply and install mains operated

ionisation smoke detector with rechargeable DC battery or condensor back up self contained to BS 5446 kitemark certified with hush button including make all necessary connections to supply including junction box, reconnect test and make good on completion, and remove waste and debris.

872015 U SMOKE DETECTORS:INSTALL OPTICAL IONISATION SYSTEM NO 104.54 Smoke Detectors:Isolate, supply and install 2 mains operated

smoke detectors with rechargeable DC battery or condensor back up on two separate floors in a single house or maisonette, one ionisation and one optical smoke detector self contained type to BS 5446 kitemark certified with hush button, make all necessary connections to supply including junction box and interlink the two detectors including mini trunking, reconnect, test and make good on completion, and remove waste and debris.

Page 298: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

264 Local Space Housing

872017 U SMOKE DETECTOR:INSTALL ADDITIONAL DETECTOR NO 77.38 Smoke Detector:Extra to supply and install 2 mains operated smoke

detectors for additional interlinked ionisation smoke detector with rechargeable DC battery or condensor backup self contained type to BS 5446 certified with hush button on additional floors, including make all necessary connections to supply including junction box and interlink the three detectors including mini trunking, reconnect, test and make good on completion, and remove waste and debris.

872020 U SMOKE DETECTOR:RENEW WITH OPTICAL TYPE NO 81.43 Smoke Detector:Renew existing with mains operated optical smoke

detector with rechargeable DC battery or condensor back up self contained type to BS 5446 kitemark certified with hush button, including back plate and all necessary connections to existing wiring, test and make good on completion, where interlinked detectors are replaced new detectors must be compatible with existing, and remove waste and debris.

872023 U SMOKE DETECTOR:RENEW WITH IONISATION TYPE NO 74.48 Smoke Detector:Renew existing with mains operated ionisation

smoke detector with rechargeable DC battery or condensor back up self contained type to BS 5446 kitemark certified with hush button including back plate and all necessary connections to existing wiring, test and make good on completion, where interlinked detectors are replaced new detectors must be compatible with existing, and remove waste and debris.

872025 U SMOKE DETECTOR:SERVICE AND OVERHAUL HARD WIRE IT 12.85 Smoke Detector:Undertake annual service and overhaul any type of

hard wired smoke detector, switch power off, vacuum through vents, switch power on, test, all work to be carried in strict conformity to the manufacturer’s instructions, renew battery as necessary and leave in working order and remove waste and debris (rate per dwelling).

872027 U SMOKE DETECTOR:SERVICE AND OVERHAUL BATTERY IT 12.85 Smoke Detector:Undertake annual service and overhaul any type of

battery operated smoke detector, vacuum through vents, test, all work to be carried in strict conformity to the manufacturer’s instructions, renew battery as necessary and leave in working order and remove waste and debris (rate per dwelling).

Heat Detectors 872101 U HEAT DETECTOR:INSTALL NO 95.03 Heat Detector:Isolate, supply and install mains operated rate of rise

or fixed temperature heat detector including make all necessary connections to supply including junction box, reconnect, test and make good on completion, and remove waste and debris.

Carbon Monoxide Detectors 872201 U CARBON MONOXIDE DETECTOR:INSTALL MAINS OPERATED NO 103.81 CM Detector:Isolate, supply and install mains operated carbon

monoxide detector including make all necessary connections to supply and make good on completion, and remove waste and debris.

Page 299: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

265 Local Space Housing

872203 U CARBON MONOXIDE DETECTOR:SERVICE OVERHAUL WIRED NO 12.85 CM Detector:Undertake annual service and overhaul any type of

hard wired carbon monoxide detector, switch power off, vacuum through vents, switch power on, test, all work to be carried in strict conformity to the manufacturer’s instructions, renew battery as necessary and leave in working order and remove waste and debris (rate per dwelling).

872205 U CARBON MONOXIDE DETECTOR:INSTALL BATTERY TYPE NO 33.12 CM Detector:Supply and install battery operated carbon monoxide

detector to BS7860 AICO E1205A or equal and approved including fix to structure in accordance with the manufacturer’s instructions test and make good on completion, and remove waste and debris.

Gas Detectors 872301 U GAS DETECTOR:INSTALL NO 71.69 Gas Detector:Isolate, supply and install mains operated gas detector

including make all necessary connections to supply including junction box, reconnect, test and make good on completion, and remove waste and debris.

Landlords Lighting etc. Time Switches 880101 R TIME SWITCH:RESET CLOCK OR SWITCH NO 5.68 Time Switch:Reset time switch clock or time lag switch and leave in

working order and remove waste and debris.

880103 R TIME SWITCH:REPAIR SWITCH CLOCK NO 12.80 Time Switch:Repair time switch clock and leave in working order

and remove waste and debris.

880105 R TIME SWITCH:RENEW SWITCH CLOCK NO 34.87 Time Switch:Isolate supply, disconnect, clear away and renew time

switch clock, remake all necessary connections, reconnect electricity supply, undertake electrical tests, make good and leave in working order and remove waste and debris.

880107 R TIME SWITCH:RENEW PHOTO ELECTRIC TYPE NO 41.96 Time Switch:Isolate supply, disconnect, clear away and renew

photo electric dusk/dawn switch, remake all necessary connections, reconnect electricity supply, test, make good and leave in working order and remove waste and debris.

880109 R TIME SWITCH:RENEW WITH PHOTO ELECTRIC TYPE NO 64.85 Time Switch:Isolate supply, disconnect, clear away any existing

time clock and renew with photo electric dusk/dawn switch including all additional wiring, remake all connections, reconnect electricity supply, test, make good and leave in working order and remove waste and debris.

880111 R TIME SWITCH:RENEW PASSIVE INFRA RED NO 44.51 Time Switch:Isolate supply, disconnect, clear away and renew

passive infra red detector switch, remake all necessary connections, reconnect electricity supply, test, make good and leave in working order and remove waste and debris.

Page 300: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

266 Local Space Housing

880115 R TIME SWITCH:RENEW WITH TIME LAG SWITCH NO 55.40 Time Switch:Isolate supply, disconnect, clear away and renew any

plate switch with time delay switch disconnect, clear away and renew, remake all connections, reconnect to electricity supply, undertake electrical tests, set switch, make good and leave in working order and remove waste and debris.

880113 R EXTERNAL LIGHT:INSTALL 1000W PIR UNIT COMPLETE NO 79.12 External Light:Supply and install in approved location passive infra

red detector unit with 1000w lamp, PIR switch, all necessary wiring and control switch and connection to electrical supply, test, set, make good and leave in working order and remove waste and debris.

880112 R EXTERNAL LIGHT:INSTALL 150W PIR UNIT COMPLETE NO 66.06 External Light:Supply and install in approved location passive infra

red detector unit with 150w lamp, PIR switch, all necessary wiring and control switch and connection to electrical supply, test, set, make good and leave in working order and remove waste and debris.

880114 R EXTERNAL LIGHT:INSTALL 500W PIR UNIT COMPLETE NO 70.06 External Light:Supply and install in approved location passive infra

red detector unit with 500w lamp, PIR switch, all necessary wiring and control switch and connection to electrical supply, test, set, make good and leave in working order and remove waste and debris.

Emergency Lighting Fittings 881001 R EMERGENCY LIGHTING:RENEW SELF CONTAINED FITTING NO 68.96 Emergency Lighting:Renew or supply and install self contained non-

maintained 3hr duration completion with glass diffuser, plugged and screwed to structure, including making all connections to existing wiring, test and make good on completion, and remove waste and debris.

881003 R EMERGENCY LIGHTING:RENEW EXIT SIGN NO 96.20 Emergency Lighting:Renew or supply and install exit sign

515x190x58mm maintained type 3hr duration complete with tube to BS 5266 surface mounted, plugged and screwed to structure, including making all connections to existing wiring, test and make good on completion, and remove waste and debris.

881004 U EMERGENCY LIGHTING:SERVICE ANY TYPE NO 18.60 Emergency Lighting:Attend and carry out service to emergency

lighting installation complete to block of dwellings or scheme, including provision of minor parts as necessary, test and leave in working order and remove waste and debris.

881009 U EMERGENCY LIGHTING:RENEW BATTERY TO FITTING NO 33.12 Emergency Lighting:Renew self contained re-chargeable battery

pack to any self contained emergency light fitting including isolate supply replace battery unit, remake all connections, reconnect electricity, test and leave in working order and remove waste and debris.

Page 301: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

267 Local Space Housing

Inspections 885001 R INSPECT:LANDLORDS LIGHTS NE 4 FLOORS IT 24.28 Inspect:Inspect landlord's lighting points to block of flats or

maisonettes ne 4 No. floors, including renew defective lamps, bulbs, tubes and reset time clocks, report to the Client Representative in writing (measured per access staircase and associated balcony's, walkways, landings, lift areas and corridors).

885003 R TESTING:THREE MONTHLY TEST EMERGENCY LIGHTING IT 25.55 Testing:Three monthly test and inspection of emergency lighting

system to sheltered housing accommodation, report to Client Representative in writing.

885005 R TESTING:MONTHLY TEST EMERGENCY LIGHTING IT 25.55 Testing:Monthly test and inspection of emergency lighting system

to sheltered housing accommodation, report to Client Representative in writing.

Overnight Temporary Connections Temporary Connections 891001 U POWER:TEMPORARY CONNECTION NO 24.39 Power:Switch off supply, install suitable temporary power circuit,

energise and later remove temporary connections for power circuit.

891003 U LIGHT:TEMPORARY CONNECTION NO 18.60 Light:Switch off supply, install suitable temporary lighting circuit,

energise and later remove temporary connections for lighting circuit.

891005 U POWER AND LIGHT:TEMPORARY CONNECTION NO 37.32 Power and Light:Switch off supply, install suitable temporary

lighting and power circuit, energise and later remove temporary connections/ circuit for power and lighting circuit.

Temporary Equipment Hire 20.17 891007 U HEATER:SUPPLY TEMPORARY 3KW HEATER [RATE PER WEEK] WK Heater:Supply a temporary 3 Kilowatt electric convector heater for

a period of time specified by the Client Representative (per week).

891009 U WATER HEATER:SUPPLY TEMPORARY [RATE PER WEEK] WK 30.67 Heater:Supply, maintain and remove on completion a temporary electric

water heater for a period of time specified by the Client Representative (per week).

891011 U DE-HUMIDIFIER:SUPPLY TEMPORARY [RATE PER WEEK] WK 82.36 De-humidifier:Supply, maintain and remove on completion a temporary

electric de-humidifier for a period of time specified by the Client Representative, including periodic emptying (per week).

891013 U WET-VAC:SUPPLY TEMPORARY [RATE PER WEEK] WK 32.67 Heater:Supply, maintain and remove on completion a temporary electric

wet-vac machine for a period of time specified by the Client Representative (per week).

Page 302: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

268 Local Space Housing

Earthing Earthing - Plumbing Installations 892001 R EARTH:CROSS BOND PLUMBING IT 20.51 Earth:Install and connect earth strips and wire to cross bond pipes

to any pipes, appliance or tank, connect to earth source and earth clip, with earth tags and cable clips and remove waste and debris. [per item crossbonded]

892019 R EARTH:RENEW MAIN EQUIPOTENTIAL BONDING IT 25.81 Earth:Disconnect, strip out, clear away and renew earthing cable of

suitable size, clamps and accessories from main switch gear and consumer units to incoming water, gas or electric supply and remove waste and debris..[per item]

892023 R EARTH:INSTALL ELECTRODE AND CABLE NO 112.91 Earth:Supply and install earth electrode, 16.00mm PVC insulated

single core earthing cables and clamps and galvanised inspection box and lid and install earth wire to mains position and connect and remove waste and debris..

892025 R EARTH:REFIX ELECTRODE NO 17.03 Earth:Refix earth electrode and galvanised inspection box and lid. 892027 R EARTH:INSTALL EARTHBOND COMPLETE IT 207.78 Earth:Install complete earthbonding system to dwelling, all as

current regulations and remove waste and debris.

892050 R EARTH:CROSS BOND BATHROOM IT 49.69 Earth:Supplemental equipotential bonding all circuits [heater,

lighting, shower, fan] in bathroom, to the nearest earth point in accordance with current regulations with cable, clips and tags, and remove waste and debris.

Earthing - Central Heating Equipment 892107 R EARTH:SUPPLEMENTARY EQUIPOTENTIAL BONDING ANY ITEM IT 14.21 Earth:Supplemental equipotential bonding to any isolated metal

item or pipe to the nearest earth point in accordance with current regulations with cable, clips and tags, and remove waste and debris.

892109 R EARTH:INSTALL 16MM CABLE LM 9.74 Earth:Install 16mm PVC insulated single core earthing cable,

connect to Electricity Companies earth point, terminate with and including earth block multi-connector, and remove waste and debris.

892111 R EARTH:RECONNECT EARTH BOND IT 6.40 Earth:Reconnect loose or detached earth bond, renew any missing

components or earth tags to effect bond in accordance with current regulations.

Page 303: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

269 Local Space Housing

Testing Testing - Occupied Property 895001 R TEST:OCCUPIED PROPERTY CERTIFICATE IT 100.91 Test:Carry out test of domestic installation to occupied property

complete comprising continuity, insulation resistance, polarity, earth fault loop impedance and operation of residual current operated device, disconnect, repair and renew as necessary after removal of illegal wiring and components, and provide report and NICEIC/ECA test certificate to the Client Representative, and remove waste and debris..

895002 R TEST:OCCUPIED PROPERTY POST REPAIRS CERTIFICATE IT 56.77 Test:Carry out test of domestic installation to occupied property

complete comprising continuity, insulation resistance, polarity, earth fault loop impedance and operation of residual current operated device, following any repair or alteration works and provide NICEIC test certificate to Client Representative.

895003 R TEST:OCCUPIED PROPERTY AND REPORT IT 75.37 Test:Carry out test of domestic installation to occupied property

complete comprising continuity, insulation resistance, polarity, earth fault loop impedance and operation of residual current operated device, disconnect, repair and renew as necessary after removal of illegal wiring and components and report to the Client Representative and remove waste and debris, (any repairs required to be ordered separately by Client Representative).

Portable Appliance Electrical Equipment - Annual Testing 895501 R PORTABLE APPLIANCE:ANNUAL TEST - ONLY ITEM NO 17.03 Portable Appliance:Annual inspection, electrical testing, certification

and labelling of Client’s owned portable appliance of any type, under the Electricity at Work Regulations 1989 and provide written report to Client Representative (to be claimed for each item tested and certified). (only one item tested at any one location]

895503 R PORTABLE APPLIANCE:ANNUAL TEST - 2-3 ITEMS NO 6.81 Portable Appliance:Annual inspection, electrical testing, certification

and labelling of Client’s owned portable appliance of any type, under the Electricity at Work Regulations 1989 and provide written report to Client Representative (to be claimed for each item tested and certified). (2-3 items tested at one location).

895505 R PORTABLE APPLIANCE:ANNUAL TEST - 4-10 ITEMS NO 5.11 Portable Appliance:Annual inspection, electrical testing, certification

and labelling of Client’s owned portable appliance of any type, under the Electricity at Work Regulations 1989 and provide written report to Client Representative (to be claimed for each item tested and certified). (4-10 items tested at one location).

895507 R PORTABLE APPLIANCE:ANNUAL TEST - OVER 10 ITEMS NO 3.97 Portable Appliance:Annual inspection, electrical testing, certification and

labelling of Client’s owned portable appliance of any type, under the Electricity at Work Regulations 1989 and provide written report to Client Representative (to be claimed for each item tested and certified). (over 10 items tested at one location).

Page 304: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

270 Local Space Housing

Testing - Unoccupied Property 896001 X TEST:UNOCCUPIED PROPERTY CERTIFICATE IT 116.67 Test:Carry out test of domestic installation to unoccupied property

complete comprising continuity insulation resistance, polarity, earth fault loop impedance and operation of residual current operated device, disconnect, repair and renew as necessary after removal of illegal wiring and components, and provide report and NICEIC/ECA test certificate to the Client Representative, and remove waste and debris..

896003 X TEST:UNOCCUPIED PROPERTY REPORT IT 82.61 Test:Carry out test of domestic installation to unoccupied property

complete comprising continuity insulation resistance, polarity, earth fault loop impedance and operation of residual current operated device, disconnect, repair and renew as necessary after removal of illegal wiring and components and report to the Client Representative and remove waste and debris, (any repairs required to be ordered separately by Client Representative).

Water Penetration 897003 E SEVERE PENETRATION:DISCONNECT REPAIR TEST IT 76.93 Severe Water Penetration:Disconnect lighting and power supply after

severe water penetration, burst pipe or tank or flooding, provide temporary supply and isolate affected components, repair and reconnect, and undertake test comprising continuity, insulation resistance, polarity, earth fault loop impedance and operation of residual current operated device and provide a report and NICEIC test certificate to the Client Representative.

Client Inspections - Electrical 898001 E CLIENT INSPECTION:ELECTRICAL IT 18.73 Lighting:Locate fault in any lighting circuit including any necessary

testing and report to Client Representative (any repairs required to be ordered separately, can only be claimed if instructed by Client Representative).

Page 305: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

271 Local Space Housing

DISABLED ADAPTATIONS AND MINOR WORKS Stairlifts Stairlifts - Ancillary Works 910001 R STAIRLIFT:OBTAIN QUOTE AND ATTEND IT 26.25 Stairlift:Upon the specific instruction of the Client Representative

obtain a quotation from an approved Contractor for the provision of stairlift at the designated property and provide all necessary attendance on any subsequent installations.

910003 R STAIRLIFT:INSTALL FUSED SPUR NO 100.83 Stairlift:Isolate supply and install new 13 amp switched fused spur

including connection to existing consumer unit with cable run in mini-trunking or rigid PVC conduit chased into wall, make all necessary connections, reconnect electricity supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

910005 R STAIRLIFT:INSTALL FUSED SPUR AND WAY NO 127.05 Stairlift:Isolate supply and install new 13 amp switched fused spur

including connection to existing consumer unit and provision of additional way to consumer unit, cable run in mini-trunking or rigid PVC conduit chased into walls, make all necessary connections, reconnect electricity supply, undertake electrical tests, provide certificate, make good on completion, and remove waste and debris.

Electrical Works Consumer Unit 921001 R CONSUMER UNIT:REPOSITION IT 57.07 Consumer Unit:Disconnect, remove and reposition any consumer

unit to suit wheelchair access and reconnect, test and make good, and remove waste and debris.

Socket Outlets 922001 R SOCKET:RAISE HEIGHT-MINI TRUNK OR KIT IT 49.32 Socket:Raise height of any existing single or double socket outlet,

ne 1.5m with wiring run in plastic mini trunking including all fittings and switched single or double outlets or proprietary extended plug kit including fix to wall, make all connections, electrical tests and make good finishes, and remove waste and debris.

Switch Plate 923001 R SWITCH:REPLACE WITH WIDE ROCKER NO 9.55 Switch:Replace any switch plate with wide rocker switch plate

including make all connections and electrical tests and remove waste and debris.

Page 306: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

272 Local Space Housing

923003 R SWITCH:LOWER ANY SWITCH IT 44.49 Switch:Lower height of any existing switch plate with wiring run in

plastic mini-trunking including blanking plate to existing switch and new surface mounted switch plate and box, make all connections, electrical tests and make good finishes, and remove waste and debris.

Thermostat 924001 R THERMOSTAT:LOWER POSITION IT 24.67 Thermostat:Lower height of room thermostat with wiring run in

plastic mini-trunking including blanking plate to existing thermostat outlet and refix existing thermostat in lower position including make all connections, electrical tests and make good finishes, and remove waste and debris.

Communication Systems Door Entry 931001 R DOOR ENTRY:REMOTE LOCK SYSTEM IT 225.33 Door Entry:Supply and install proprietary door entry system

comprising remote lock control, internal/external speaker system including all necessary wiring, connections and make good all finishes, and remove waste and debris.

931003 R DOOR ENTRY:SUPPLY AND FIX VISUAL AID IT 210.36 Door Entry:Supply and fix proprietary strobe type visual indicator to

any door bell/door entry system including all necessary wiring, connections and make good all finishes, and remove waste and debris.

931005 R TELEPHONE:SUPPLY AND FIX VISUAL AID IT 53.93 Telephone:Supply and fix proprietary strobe type visual indicator to

telephone installation including all necessary wiring, connections and make good all finishes, and remove waste and debris.

Smoke Detector 932001 R SMOKE DETECTOR:VISUAL AID TYPE IT 104.25 Smoke Detector:Supply and install smoke detector incorporating

strobe type visual aid including all wiring and connection to electrical supply and wiring and connection to make good all finishes, and remove waste and debris.

Grab Rails, Handrails and Balustrades Grabrails - Proprietary - Stainless Steel, Polyester Coated,

or Reinforced Plastic as Specified

941001 R GRAB BAR:SUPPLY 305MM STRAIGHT NO 55.78 Grab Bar:Supply and fix 32mm diameter, 2 flange proprietary

straight grab bar 305mm long of any type specified by Client Representative, fixed to any background including all plugging and make good finishes, and remove waste and debris.

Page 307: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

273 Local Space Housing

941002 R GRAB BAR:SUPPLY 450MM STRAIGHT NO 61/57 Grab Bar:Supply and fix 32mm diameter, 2 flange proprietary

straight grab bar 450mm long of any type specified by Client Representative, fixed to any background including all plugging and make good finishes, and remove waste and debris.

941003 R GRAB BAR:SUPPLY NE 610MM STRAIGHT NO 67.98 Grab Bar:Supply and fix 32mm diameter, 2 flange proprietary

straight grab bar ne 610mm long of any type specified by Client Representative, fixed to any background including all plugging and make good finishes, and remove waste and debris.

941005 R GRAB BAR:SUPPLY NE 1219MM STRAIGHT NO 112.39 Grab Bar:Supply and fix 32mm diameter, 3 flange proprietary

straight grab bar ne 1219mm long of any type specified by Client Representative, fixed to any background including all plugging and make good finishes, and remove waste and debris.

941007 R GRAB BAR:SUPPLY 305/305MM ANGLED NO 78.18 Grab Bar:Supply and fix 32mm diameter, 2 flange proprietary

angled grab bar 305x305mm of any type specified by Client Representative, fixed to any background including all plugging and make good finishes, and remove waste and debris.

941009 R GRAB BAR:SUPPLY 213/813MM ANGLED NO 107.70 Grab Bar:Supply and fix 32mm diameter, 2 flange proprietary

angled grab bar 203x813mm of any type specified by Client Representative, fixed to any background including all plugging and make good finishes, and remove waste and debris.

941011 R GRAB BAR:SUPPLY 406/813MM ANGLED NO 126.68 Grab Bar:Supply and fix 32mm diameter, 3 flange proprietary

angled grab bar 406x813mm of any type specified by Client Representative, fixed to any background including all plugging and make good finishes, and remove waste and debris.

941013 R GRAB BAR:SUPPLY 508/1016MM ANGLED NO 145.41 Grab Bar:Supply and fix 32mm diameter, 3 flange proprietary

angled grab bar 508x1016mm of any type specified by Client Representative, fixed to any background including all plugging and make good finishes, and remove waste and debris.

941015 R GRAB BAR:SUPPLY 762/838MM FREESTANDING NO 189.30 Grab Bar:Supply and fix 32mm diameter, 2 flange or 3 flange

proprietary freestanding grab bar 762x838mm of any type specified by Client Representative, fixed to any background wall and floor including all plugging and make good finishes, and remove waste and debris.

941017 R GRAB BAR:SUPPLY OVERLAP BATH NO 227.50 Grab Bar:Supply and fix 32mm diameter, 2 flange proprietary

overlap grab bar to bath, ne 457x230x511mm high of any type specified by Client Representative, fixed to any background floor including all plugging and make good finishes, and remove waste and debris.

Page 308: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

274 Local Space Housing

941019 R GRAB BAR:SUPPLY 914/305MM BATH NO 179.89 Grab Bar:Supply and fix 32mm diameter, 3 flange proprietary

specialised grab bar to bath, 914x305x813mm high of any type specified by Client Representative, fixed to any background wall and floor including all plugging and make good finishes, and remove waste and debris.

941021 R GRAB BAR:SUPPLY NE1219/305MM BATH NO 229.58 Grab Bar:Supply and fix 32mm diameter, 3 flange proprietary

specialised grab bar to bath, ne 1219x305x813mm high of any type specified by Client Representative, fixed to any background wall and floor including all plugging and make good finishes, and remove waste and debris.

941023 R GRAB BAR:SUPPLY 914/305/813 BATH NO 261.77 Grab Bar:Supply and fix 32mm diameter, 4 flange proprietary

specialised grab bar to bath, 914x305x813mm high of any type specified by Client Representative, fixed to any background wall and floor including all plugging and make good finishes, and remove waste and debris.

941025 R GRAB BAR:SUPPLY 914/305/305 BATH NO 216.01 Grab Bar:Supply and fix 32mm diameter, 4 flange proprietary

specialised grab bar to bath, 914x305x305mm high of any type specified by Client Representative, fixed to any background wall and floor including all plugging and make good finishes, and remove waste and debris.

941027 R GRAB BAR:SUPPLY 610/610/508 WC NO 271.93 Grab Bar:Supply and fix 32mm diameter, 4 flange proprietary

specialised grab bar to wc 610x610x508mm high of any type specified by Client Representative, fixed to any background wall including all plugging and make good finishes, and remove waste and debris.

941029 R GRAB BAR:SUPPLY 610/610/813 SHOWER NO 187.58 Grab Bar:Supply and fix 32mm diameter, 4 flange proprietary

vert/horiz. grab bar to shower, 610x610x813mm high of any type specified by Client Representative, fixed to any background wall including all plugging and make good finishes, and remove waste and debris.

941031 R GRAB BAR:SUPPLY 508/1016/813 SHOWER NO 209.25 Grab Bar:Supply and fix 32mm diameter, 4 flange proprietary

vert/horiz. grab bar to shower, 508x1016x813mm high of any type specified by Client Representative, fixed to any background wall including all plugging and make good finishes, and remove waste and debris.

941033 R GRAB BAR:SUPPLY 610/1219/813 SHOWER NO 226.19 Grab Bar:Supply and fix 32mm diameter, 4 flange proprietary

vert/horiz. grab bar to shower, 610x1219x813mm high of any type specified by Client Representative, fixed to any background wall including all plugging and make good finishes, and remove waste and debris.

Page 309: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

275 Local Space Housing

941035 R GRAB BAR:SUPPLY 914/914/813 SHOWER NO 236.35 Grab Bar:Supply and fix 32mm diameter, 5 flange proprietary

vert/horiz. grab bar to shower, 914x914x813mm high of any type specified by Client Representative, fixed to any background wall including all plugging and make good finishes, and remove waste and debris.

941037 R GRAB BAR:SUPPLY SWING ASIDE NO 368.96 Grab Bar:Supply and fix 32mm diameter, 2 flange proprietary swing

aside movable grab bar ne 700x965mm of any type specified by Client Representative, fixed to any background wall and floor including all plugging and make good finishes, and remove waste and debris.

941039 R GRAB BAR:SUPPLY SWING UP NO 128.15 Grab Bar:Supply and fix 32mm diameter, 2 flange proprietary swing

up movable grab bar of any type specified by Client Representative, fixed to any background wall including all plugging and make good finishes, and remove waste and debris.

941045 R GRAB BAR:SUPPLY VERTICAL POLE NO 231.37 Grab Bar:Supply and fix 35mm diameter, 2 flange proprietary

vertical pole grab bar average length 2.70m of any type specified by Client Representative, fixed to any background ceiling and floor including all plugging and make good finishes and additional strengthening to floor or ceiling.

941041 R GRAB BAR:REMOVE AND REFIX NO 17.48 Grab Bar:Remove any type of grab bar and refix in new position to

any background wall and floor including all plugging and making good.

941043 R GRAB BAR:RETURN TO STORE NO 18.22 Grab Bar:Return to store, carefully remove any type of grab bar,

make good finishes and transport to store.

Handrails 943001 R HANDRAIL:SUPPLY PROPRIETARY TO WALL LM 95.18 Handrail:Supply and fix ne 45mm diameter anodised aluminium or

polyester coated proprietary wall mounted handrailing fixed level or to gradient with fixed or adjustable wall brackets including all ends, angles, intersections, etc and make good all finishes, and remove waste and debris.

943009 R HANDRAIL:SUPPLY AND FIX MOPSTICK ON BRACKETS LM 25.84 Handrail:Supply and fix 50x50mm softwood mopstick handrail on

and including brackets, plugged and screwed to walls, make good finishes and decorate, and remove waste and debris.

943017 R HANDRAIL:SUPPLY AND FIX KEE KLAMP TO WALL LM 25.47 Handrail:Supply and fix galvanised mild steel tubular kee-klamp wall

mounted handrail comprising 48mm diameter rails and brackets fixed level or to gradient to wall including all necessary plugging, make good finishes and decorate, and remove waste and debris.

Page 310: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

276 Local Space Housing

Balustrading 943005 R BALUSTRADE:SUPPLY AND FIX PROPRIETARY 1.1M HIGH LM 292.59 Balustrade:Supply and fix ne 45mm diameter anodised aluminium

or polyester coated proprietary balustrade ne 1100mm high consisting of two horizontal rails with post supports, top or side fixed to level or gradient including all ends, angles, intersections and make good finishes, and remove waste and debris.

943019 R BALUSTRADE:SUPPLY AND FIX KEE KLAMP LM 68.93 Balustrade:Supply and fix galvanised mild steel tubular kee-klamp

balustrade, ne 1100mm high comprising 48mm diameter horizontal rails, 48mm diameter standards at 1m centres, set mortices in mortar, make good finishes and decorate, and remove waste and debris.

Plumbing Works Sanitary Fittings 951001 R WC SUITE:INSTALL SPECIAL NEEDS TYPE NO 302.82 WC Suite:Renew existing with special needs suite including wc pan

fixed with brass or non-ferrous screws to floor, including any necessary plugging, 6 litre vitreous china low level cistern plugged to wall with overflow, syphon, silencer pipe, float handle, ball valve, 32mm diameter flush pipe, wc cone reconnect to existing supply and overflow pipework, provide new service valve if not already installed, make flush pipe and soil pipe joints with and including 'multiquik' connectors, and test all joints, and fix new plastic seat and lid to pan, make good wall and floor finishes, and remove waste and debris.

951003 R WC SUITE:INSTALL CLOSE COUPLED SPECIAL NEEDS TYPE NO 343.82 WC Suite:Renew existing with close coupled special needs suite

with wc pan fixed with brass or non-ferrous screws to floor, including all plugging, 6 litre vitreous china cistern plugged to wall with overflow, syphon, silencer pipe, float, handle and ball valve, reconnect to existing supply and overflow pipework, provide new service valve if not already installed, make soil pipe joint with and including 'multiquik' connectors and test all joints, and fix new plastic seat and lid to pan, make good wall and floor finishes, and remove waste and debris.

951005 R WC PAN:INSTALL SPECIAL NEEDS TYPE NO 197.83 WC Pan:Renew wc pan with special needs wc pan fixed with brass

or non-ferrous screws to floor, including plugging, remake joints including joint to soil pipe with 'multiquik' connectors, and fix new plastic seat and lid to pan, make good floor finishes, and remove waste and debris.

951007 R BASIN:INSTALL ADJUSTABLE HEIGHT TYPE NO 463.91 Basin:Renew any type of wash hand basin with special needs

adjustable height basin complete with new taps and waste fitting, plug and chain and plastic trap, reconnect to existing supplies and waste with flexible connections including any adjustments to pipework, provide new service valves if not already installed and test, make good existing or supply and fix new glazed wall tiling, make good and crossbond, make good wall and floor finishes, and remove waste and debris.

Page 311: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

277 Local Space Housing

951009 R BATH:INSTALL SPECIAL NEEDS TYPE NO 729.49 Bath:Renew bath with special needs bath with rim and internal bath

seat complete with new taps and waste reconnect to existing supply pipework including any adjustments, provide new service valves if not already installed, complete with new plug and chain, plastic trap, connect to waste pipework, remove existing bath panels and frame- work and fix new proprietary front and end bath panels including all necessary fixings and supports, make good existing and renew glazed wall tile splashback fixed with adhesive including all rounded edges and labours, silicone sealant between splashback and bath, and crossbond, make good wall and floor finishes, and remove waste and debris.

951011 R BATH:INSTALL SPECIAL NEEDS HIP TYPE NO 508.53 Bath:Renew bath with special needs hip bath complete with new

taps and waste reconnect to existing supply pipework including any adjustments, provide new service valves if not already installed, complete with new plug and chain, plastic trap, connect to waste pipework including any adjustments, test, crossbond and make good all wall and floor finishes, and remove waste and debris.

Taps 952001 R TAPS:INSTALL BASIN LEVERS - PAIR IT 96.86 Taps:Renew pair of taps to wash hand basin with pair of 15mm

ceramic disc lever taps including, turn water off/on, remove old, connect new taps to existing pipework including remove/refix basin securely if required, reinstate water supply, test on completion and make good, and remove waste and debris.

952003 R TAPS:INSTALL SINK LEVERS - PAIR IT 95.87 Taps:Renew pair of taps to sink with pair of 15mm high neck

ceramic disc lever taps including turn water off/on, remove old, connect new taps to existing pipework, reinstate water supply, test on completion and make good, and remove waste and debris.

952005 R TAPS:INSTALL BATH LEVERS - PAIR IT 130.26 Taps:Renew pair of taps to bath with pair of 22mm ceramic disc

lever taps including turn water off/on, remove panels/studding for access and refix on completion, remove existing taps and fix new and connect to existing pipework, reinstate water supply, test on completion and make good, and remove waste and debris.

952007 R STOP TAP:RESITE AND RENEW WITH LEVER IT 55.44 Stop Tap:Resite position of internal stop tap including replace with

lever operated stop tap, locate, turn water supply off/on, run supply pipe to convenient position for wheelchair access, install new stop tap and make all necessary connections and make good, and remove waste and debris.

Showers/Bath Aids Shower Seat 961001 R SEAT:SUPPLY AND FIX SHOWER SEAT NO 106.24 Seat:Supply and fix proprietary shower seat including all necessary

plugging and securely fixing to wall and floor as appropriate and all making good, and remove waste and debris.

Page 312: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

278 Local Space Housing

961019 R SEAT:SUPPLY AND FIX HINGED WITH LEG NO 284.23 Seat:Supply and fix proprietary heavy duty hinged shower seat with

support leg including all necessary plugging and securely fixing to wall and floor as appropriate and all making good, and remove waste and debris.

Soap Dish 962001 R SOAP DISH:SUPPLY AND FIX WHEELCHAIR HEIGHT NO 35.94 Soap Dish:Supply and fix soap dish to suit wheelchair height

including all making good, and remove waste and debris..

Electric Showers 963001 R SHOWER:RENEW 8.7 KW COMPLETE IT 338.15 Shower:Renew shower unit with 8.7 kW electric shower unit

complete incorporating advanced temperature stabiliser for constant temperature control, make all fixtures to walls, make all connections to electrical and water supplies, incorporate RCD protection, MCB 45 amp, provide new service valve if not already installed, install in line scale reducer, test, provide certificate and make good all finishes on completion, and remove waste and debris.

963003 R SHOWER:INSTALL 8.7 KW COMPLETE IT 415.32 Shower:Supply and fix new 8.7 kW electric shower unit complete

incorporating advanced temperature stabiliser for constant temperature control, make all connections to water supply including running additional pipework as necessary, provide new service valve, make electrical connections including provision of double pole switch, cable, conduit and MCB 45 amp, RCD protection, install in line scale reducer, test, provide certificate, and make good all finishes on completion, and remove waste and debris.

Shower Rooms 964001 R SHOWER ROOM:CONVERT WITH FLOOR DRAIN IT 1711.48 Shower Room:Convert existing bathroom to shower room including

disconnect existing sanitary ware as necessary and set aside, clear away bath, screed floor to falls and crossfalls to and including new floor drain complete and connect to waste, lay non slip flooring as specified by Client Representative fully skirted to ensure complete waterproofing to room, refix and reconnect sanitaryware, provide new service valves if not already installed, install 8.7kw electric shower complete including connections to supplies, DP switch, MCB 45 amp, RCD protection, install in line scale reducer, fix new shower rail and curtain, soap dish, test, provide certificate, make good, provide extra wall tiling to shower area, and remove waste and debris.

Page 313: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

279 Local Space Housing

964003 R SHOWER ROOM:CONVERT WITH SHOWER TRAY IT 1750.32 Shower Room:Convert existing bathroom to shower room including

disconnect existing sanitary ware as necessary and set aside, clear away bath, screed floor to falls and crossfalls to and including new shower tray complete and connect to waste, lay non slip flooring as specified by Client Representative fully skirted to ensure complete waterproofing to room, refix and reconnect sanitaryware, provide new service valves if not already installed, install 8.7kw electric shower complete including connections to supplies, DP switch, MCB 45 amp, RCD protection, install inhibitor, fix new shower rail and curtain and soap dish, test, provide certificate, make good, provide extra wall tiling to shower area, and remove waste and debris.

Shower Rails and Curtains 965001 R SHOWER:RENEW RAILS AND CURTAINS IT 70.08 Shower:Renew any size and type of shower rail and curtain

including remove any defective rails, fix new rails with plastic plugs and matching non ferrous screws including remove and rehang curtains, make good all finishes, and remove waste and debris.

965003 R SHOWER:RENEW CURTAIN IT 27.52 Shower:Renew any type of shower curtain to existing rails including

remove and refix rails as found expedient, and remove waste and debris.

Kitchen Units Kitchen Units - Adjustable Specification for Special Needs 970001 R UNIT:REMOVE ANY UNIT AND CLEAR AWAY NO 6.57 Unit:Remove any size of existing base unit and worktop over or any

size of wall unit and remove waste and debris..

970003 R BASE UNIT:SUPPLY 300MM LONG ADJUSTABLE HEIGHT NO 181.19 Base Unit:Supply and fix 300mm long adjustable height base unit

and worktop over complete, make good walls and floors including where any existing units removed, seal junction of worktop/walls with silicone sealant and remove waste and debris.

970005 R BASE UNIT:SUPPLY 400MM LONG ADJUSTABLE HEIGHT NO 223.84 Base Unit:Supply and fix 400mm long adjustable height base unit

and worktop over complete, make good walls and floors including where any existing units removed, seal junction of worktop/walls with silicone sealant and remove waste and debris.

970007 R BASE UNIT:SUPPLY 500MM LONG ADJUSTABLE HEIGHT NO 244.88 Base Unit:Supply and fix 500mm long adjustable height base unit

and worktop over complete, make good walls and floors including where any existing units removed, seal junction of worktop/walls with silicone sealant and remove waste and debris.

970009 R BASE UNIT:SUPPLY 600MM LONG ADJUSTABLE HEIGHT NO 261.43 Base Unit:Supply and fix 600mm long adjustable height base unit

and worktop over complete, make good walls and floors including where any existing units removed, seal junction of worktop/walls with silicone sealant and remove waste and debris.

Page 314: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

280 Local Space Housing

970011 R BASE UNIT:SUPPLY 1000MM LONG ADJUSTABLE HEIGHT NO 352.96 Base Unit:Supply and fix 1000mm long adjustable height base unit

and worktop over complete, make good walls and floors including where any existing units removed, seal junction of worktop/walls with silicone sealant and remove waste and debris.

970013 R SINK TOP:RENEW ADJUSTABLE HEIGHT COMPLETE NO 367.35 Sink Unit:Renew any sink unit with adjustable height proprietary

inset sink top, worktop and fascia includingturn water off/on, disconnect existing and clear away, fix new including pair of ceramic disc lever taps with flexible connections and make all connections to existing pipework, provide new service valves if not already installed, fix new waste, trap and conect to existing pipework including all adjustments necessary, fit plug/chain, make good all finishes including where existing unit removed seal junction to wall with silicone sealant, crossbond and test, and remove waste and debris.

970015 R WALL UNIT:SUPPLY 300MM LONG ADJUSTABLE HEIGHT NO 90.21 Wall Unit:Supply and fix 300mm long adjustable height wall unit

complete, make good walls including where any existing units removed, and remove waste and debris.

970017 R WALL UNIT:SUPPLY 400MM LONG ADJUSTABLE HEIGHT NO 92.35 Wall Unit:Supply and fix 400mm long adjustable height wall unit

complete, make good walls including where any existing units removed, and remove waste and debris.

970019 R WALL UNIT:SUPPLY 500MM LONG ADJUSTABLE HEIGHT NO 108.49 Wall Unit:Supply and fix 500mm long adjustable height wall unit

complete, make good walls including where any existing units removed, and remove waste and debris.

970021 R WALL UNIT:SUPPLY 600MM LONG ADJUSTABLE HEIGHT NO 121.50 Wall Unit:Supply and fix 600mm long adjustable height wall unit

complete, make good walls including where any existing units removed, and remove waste and debris.

970023 R WALL UNIT:SUPPLY 1000MM LONG ADJUSTABLE HEIGHT NO 159.70 Wall Unit:Supply and fix 1000mm long adjustable height wall unit

complete, make good walls including where any existing units removed, and remove waste and debris.

Windows Window Adaptations and Ironmongery 975001 R WINDOW:RELOCATE ANY WINDOW FITTING NO 7.29 Window:Remove and refix in suitable position any window fitting

including make good where fitting removed and touch up decorations to match existing, and remove waste and debris.

975003 R WINDOW:REPLACE WITH EXTENDED ARM STAY NO 25.02 Window:Remove any existing stay and supply and fix sliding stay

with extended arm to suit special needs requirements including make good and touch up decorations to match existing, and remove waste and debris.

Page 315: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

281 Local Space Housing

975005 R WINDOW:SUPPLY AND FIX TELEFLEX GEAR NO 257.26 Window:Remove existing window fastener and supply and fix

'Teleflex' or similar approved operating gear to any opening casement and make good including touch up decorations to match existing, and remove waste and debris.

975007 R WINDOW:SUPPLY AND FIX CHAIN DRIVE HANDLE NO 89.22 Window:Remove existing window fastener and supply and fix chain

driven window fastener with operating handle including make good and touch up decorations to match existing, and remove waste and debris.

Doors Door Adaptations and Ironmongery 980001 R DOOR:SUPPLY AND FIX KICKING PLATE 300MM NO 56.11 Door:Supply and fix 16 gauge SAA kicking plate ne 900x300mm,

screw fixed to any door and remove waste and debris..

980003 R DOOR:REPLACE KNOBSET WITH LEVER HANDLES IT 12.31 Door:Remove any type of knobset furniture to door and replace

with set of lever furniture and remove waste and debris. (per door).

980005 R DOOR:CHANGE TO TWO WAY OPERATION IT 54.99 Door:Change operation of door to two-way operation including

remove door and stops, rehang door on two way hinges, make good including touch up decorations to match existing where stops removed, and remove waste and debris.

980007 R DOOR:CHANGE INWARD TO OUT OPENING IT 40.84 Door:Change operation of inward opening door to outward

opening, remove and rehang door, remove and refix stops, relocate lock or latch keep and make good where butts/keep removed, redecorate to match, and remove waste and debris.

980009 R ANGLE TRIM:FIX SAA ANGLE TRIM NO 21.37 Angle Trim:Supply and fix proprietary SAA angle trim screw fixed to

walls at external angles to provide protection to walls including make good, and remove waste and debris.

Access Facilities Ramps 985001 R RAMP:CONSTRUCT CONCRETE RAMP LM 92.86 Ramp:Construct insitu concrete ramp average 150mm thick, ne

1.50m wide overall with 50mm high insitu concrete kerbs to both sides, laid to any gradient specified ne 1:15 with pinked finish including all excavation, hardcore, reinforcement and formwork, and remove waste and debris.

985003 R RAMP:CONSTRUCT TIMBER RAMP LM 73.08 Ramp:Construct timber ramp ne 1.50m wide overall comprising

treated softwood framing with 18mm marine plywood to top and sides including forming 50mm high kerbs to both sides. ramp constructed to any gradient specified ne 1:15 with approved non slip surface finish, decorate as required, and remove waste and debris.

Page 316: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

282 Local Space Housing

Steps 985501 R STEP:FORM HALF STEP-CONCRETE IT 45.09 Step:Break out any type of existing step and reform in insitu

concrete with enlarged tread ne 600mm going and 100mm rise including all formwork and joints to existing paving and make good all works disturbed, and remove waste and debris. (measured per new step formed).

985503 R STEP:FORM HALF STEP-TIMBER/PLY IT 40.74 Step:Break out any type of existing step and reform with treated

timber framing and 18mm marine plywood, 600mm going and 100mm rise including non slip surface finish, joints to existing paving and make good works disturbed and remove waste and debris, (measured per new step formed).

Thresholds 986001 R THRESHOLD:REMOVE FOR ACCESS NO 10.93 Threshold:Remove any type of existing threshold to enable

wheelchair access and make good, and remove waste and debris.

986003 R THRESHOLD:FORM RAMP FOR WHEELCHAIR IT 24.75 Threshold:Form ramp for wheelchair access over any type of

existing threshold and make good, and remove waste and debris.

Page 317: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

283 Local Space Housing

SPECIALIST TREATMENTS Fungus and Beetle Eradication and DPC Works Reduce Existing Ground Level in Conjunction with DPC Wall

Injection

048001 R PAVING:LOWER FLAG PAVING PRIOR TO DPC INJECTION SM 73.17 Paving:Take up paving flag, set aside, excavate to lower paving to

150mm below new floor and relay flag paving on 50mm sand on 75mm compacted stone, remove waste and debris, all in conjunction with injected dpc wall treatment.

048003 R PAVING:LOWER INSITU PAVING PRIOR TO DPC INJECTION SM 98.30 Paving:Break up insitu paving, excavate to lower paving to 150mm

below new floor and lay new pcc flag paving on 50mm sand on 75mm compacted stone, remove waste and debris, all in conjunction with injected dpc wall treatment.

048005 R GARDEN:LOWER GARDEN PRIOR TO DPC INJECTION SM 18.79 Garden:Excavate in earth to reduce levels to 150mm below new

floor level and distribute surplus earth over garden areas or remove waste and debris, all in conjunction with injected dpc wall treatment.

048007 R PAVING:LOWER MACADAM PAVING BEFORE DPC INJECTION SM 94.33 Paving:Break up existing macadam excavate to lower paving to

150mm below new floor, remove spoil, fill soft spots, level and compact bottoms of excavations and fill in layers. 75mm crusher run or broken stone, blinding, 50mm base course of 20mm nominal size open textured macadam and 20mm wearing course of 6mm nominal size medium textured macadam laid to falls, crossfalls and slopes including joints to any existing finishes all in conjunction with injected dpc wall treatment, remove waste and debris.

Works to Sub-Floors due to Fungus and Beetle Eradication

or DPC Works

015501 R FLOOR:HARDCORE FILL UNDER FLOOR CM 76.82 Floor:Fill under floor with clean broken and graded hardcore or

other filling to approval of Client Representative, consolidate and blind ready to receive PVC membrane and concrete floor slab as specified all in conjunction with injected dpc wall treatment.

101601 R WALLS:REBUILD SLEEPER WALLS LM 29.91 Walls:Take down unstable 113mm honeycombed sleeper walls, not

exceeding 500mm high, clean off bricks and rebuild with salvaged bricks in cement mortar (1:3) including the provision of upto 20 per cent new common bricks, including bonding end into existing walls, and remove waste and debris.

101603 R WALLS:BUILD PIERS FOR WALL PLATE NO 20.70 Walls:Build new 225x225mm common brick piers in cement mortar

(1:3) to support new wall plate ne 500mm high.

Page 318: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

284 Local Space Housing

Chemical DPC Wall Injection 112001 R WALL 225MM:CHEMICAL INJECTION EXTERNAL DPC LM 51.07 Wall 225mm:Drill external wall and inject chemical dpc, make good

holes, all as specified, and remove waste and debris.

112003 R WALL 338MM:CHEMICAL INJECTION EXTERNAL DPC LM 72.06 Wall 338mm:Drill external wall and inject chemical dpc, make good

holes, all as specified, and remove waste and debris.

112005 R WALL 450MM:CHEMICAL INJECTION EXTERNAL DPC LM 96.44 Wall 450mm:Drill external wall and inject chemical dpc, make good

holes, all as specified, and remove waste and debris.

112007 R WALL 563MM:CHEMICAL INJECTION EXTERNAL DPC LM 117.82 Wall 563mm:Drill external wall and inject chemical dpc, make good

holes, all as specified, and remove waste and debris.

112009 R WALL 113MM:CHEMICAL INJECTION INTERNAL DPC LM 27.49 Wall 113mm:Drill internal wall and inject chemical dpc, make good

holes, all as specified, and remove waste and debris.

112011 R WALL 225MM:CHEMICAL INJECTION INTERNAL DPC LM 51.07 Wall 225mm:Drill internal wall and inject chemical dpc, make good

holes, all as specified, and remove waste and debris.

112013 R WALL CAVITY:CHEMICAL INJECT INTERNAL DPC LM 27.49 Wall Cavity:Drill 113mm thick skin of internal wall, inject chemical

dpc, make good holes, all as specified, and remove waste and debris..

112015 R WALL 338MM:CHEMICAL INJECTION INTERNAL DPC LM 65.49 Wall 338mm:Drill internal wall and inject chemical dpc, make good

holes, all as specified, and remove waste and debris..

112018 R WALL CAVITY:CHEMICAL INJECT 2 SKINS DPC LM 62.87 Wall Cavity:Drill both 113mm thick skins of hollow wall, make good

holes, all as specified, and remove waste and debris.

112020 R DWELLING:CHEMICAL DPC INJECT SURVEY IT 78.75 Dwelling:Undertake initial survey and report, mobilise to undertake

chemical injection damp proof course treatment, and provide 30 year insurance backed guarantee for chemical injection damp proof course treatment, demobilise, clear away all debris on completion to approved tip (to be ordered additional to codes 112001 to 112018).

112022 R DWELLING:ROT ERADICATION SURVEY IT 78.75 Dwelling:Undertake initial survey and report, mobilise to undertake

rot eradication treatment, and provide 30 year insurance backed guarantee for rot eradication treatment, demobilise, clear away all debris on completion to approved tip.

Irrigation of Walls 113001 R WALL:IRRIGATE WITH FUNGICIDE SM 18.79 Wall:Drill holes as necessary and pressure inject with approved

fungicidal solution all as specified, and remove waste and debris..

Page 319: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

285 Local Space Housing

Floor Renewals due to Fungus/Beetle Eradication or DPC Works

301201 R FLOOR:STRIP OUT TIMBER FLOOR SM 10.94 Floor:Strip out defective timber floor complete with any redundant

service installation attached or passing through floor in conjunction with dpc wall treatment, and remove waste and debris.

301203 R FLOOR:CLEAR ALL DEBRIS FROM VOID CM 34.58 Floor:Clear all existing debris from under floor void in conjunction

with dpc wall treatment, and remove waste and debris.

301205 R FLOOR:CUT BACK END ROTTED JOISTS NE 150MM NO 7.02 Floor:Remove remnants of any joists ne 150mm deep and other

timber from walls and brick up any pockets remaining, and remove waste and debris.

301207 R FLOOR:CUT BACK END ROTTED JOISTS NE 300MM NO 9.51 Floor:Remove remnants of any joists and other timbers over 150

and ne 300mm deep from walls and brick up any pockets remaining, and remove waste and debris.

Wall or Partition Renewals due to Fungus/Beetle

Eradication or DPC Works

301401 R LARDER:REMOVE AND REFIX INSITU LARDER IT 45.22 Larder:Remove, set aside, store and later refix built insitu, studded

larder or storage unit in conjunction with specialist treatment, reinstate entire unit including make good any damage caused whilst dismantling, and remove waste and debris..

301403 R WALL:RENEW NON LOAD PARTITION SM 94.37 Wall:Renew any non structural partition with softwood studding

faced both sides with skim coated 12.5m plasterboard and skirting, refix any fittings, make good to adjacent surfaces, all in conjunction with specialist treatmen, and remove waste and debris.t.

Kitchen Units and Cupboard Works due to Fungus/Beetle

Eradication or DPC Works

374001 R WALL:REMOVE AND REFIX BASE UNIT IN ASSOCIATION IT 18.06 Wall:Remove, set aside, store and later refix any kitchen base unit,

including worktop in conjunction with specialist treatment works, supply and fix cover mouldings and apply white silicone sealant to worktop, and remove waste and debris.

374003 R WALL:REMOVE REFIX SINK BASE UNIT IN ASSOCIATION IT 27.80 Wall:Remove, set aside, store and later refix any sinktop and base

unit in conjunction with specialist treatment works, adjust, extend pipe stubs including any new fittings, earthbond, connect, apply white silicone sealant to worktop, and remove waste and debris.

374005 R WALL:REMOVE AND REFIX WORKTOP IN ASSOCIATION LM 14.75 Wall:Remove, set aside and later refix any independent worktop

with leg and or cleat supports including provide any new cleats, drill, plug, fix all supports and apply silicone sealant to worktop all in conjunction with specialist treatment works, and remove waste and debris.

Page 320: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

286 Local Space Housing

Damp Proof Treatment Plasterwork 411201 R WALL:HACK OFF REPLASTER 1.0M BAND SM 52.60 Wall:Hack off all plaster to minimum height of 1.00m above new

floor level, after treatment works return and replaster ne 25mm thick with fair joint to existing plaster, all as specified and remove waste and debris.

411203 R WALL:HACK OFF RENDER AND SKIM 1.0M BAND SM 60.80 Wall:Hack off all plaster to minimum height of 1.00m above new

floor level, after damp treatment works return, apply 2 coat waterproof render and skim ne 25mm thick with fair joint to existing plaster as specified and remove waste and debris.

411205 R WALL:DUB OUT 25MM PRIOR REPLASTER SM 20.34 Wall:Apply dubbing out coat ne 25mm thick prior to replastering

wall, all as specified.

411207 R WALL:HACK OFF AND APPLY RENDER SM 39.87 Wall:Hack off any type plaster or rendered finish and apply two

coat waterproof cement render, finished to receive direct fixed dry lining (dry lining not included) and remove waste and debris.

411209 R WALL:HACK OFF AND APPLY NEW SKIM COAT SM 10.82 Wall:Hack off degraded plaster finish coat and apply new plaster

skim coat including fair joint to any existing plaster finish and remove waste and debris.

Plumbing Works due to Fungus/Beetle Eradication or DPC

Works

630801 R WALL:REMOVE AND REFIX WASHBASIN IN ASSOCIATION IT 53.09 Wall:Remove, set aside, store and later refix washbasin and any

pedestal in conjunction with specialist treatment works, turn water off/on, disconnect and reconnect and provide new service valves if not already installed, adjust, extend pipe stubs, connect with new fittings, make good or fix new tile splashback, renew sealant, crossbond and make good all wall and floor finishes, and remove waste and debris.

640601 R WALL:REMOVE AND REFIX WC SUITE IN ASSOCIATION IT 46.91 Wall:Remove, set aside, store, later refix WC and cistern in

conjunction with specialist treatment works. adjust, extend pipe stubs, and provide new service valve if not already installed connect with new fittings, cone and multikwick, adjust or refix wc seat, disconnect and reconnect pipework, replug wall, test and make good all wall and floor finishes, and remove waste and debris.

Timber Treatment Flooring Treatment 305803 R FLOOR:TREAT FLOOR INSECTICIDE 10% RENEWAL SM 39.81 Floor:Take up any type floorboards and treat with insecticide all

floorboards, joists, plates, bridging and other floor timbers, on completion refix floorboards including upto 10% floorboard renewal.

Page 321: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

287 Local Space Housing

305804 R DWELLING:TREAT FLOOR INSECTICIDE IT 1150.50 Dwelling:Take up all floorboards of any type, treat with insecticide

all floorboards, joists, plates, bridging, other timbers, on completion refix floorboards including upto 10% floorboard renewal, and remove waste and debris..

305805 R FLOOR:TREAT FLOOR PRESERVATIVE SM 52.10 Floor:Remove any type of floorboards and treat with three full

brush coats of preservative to BS 5707 Type F all floorboards, joists, plates, bridging and other floor timbers, on completion refix floorboards including over 10% floorboard renewal, and remove waste and debris..

305806 R DWELLING:TREAT FLOOR PRESERVATIVE IT 1298.34 Dwelling:Take up all floorboards of any type, treat with 3 coats of

preservative to BS 5707 Type F, all floorboards, joists, plates, bridging, other timbers, on completion refix floorboards including upto 10% floorboard renewal, and remove waste and debris.

305808 R DWELLING:PRESERVATIVE GUARANTEE IT 52.50 Dwelling:Provision of 30 year insurance backed guarantee for floor

preservation treatment.

305820 R DWELLING:TIMBER TREATMENT IT 919.34 Dwelling:Take up 20% of floorboards as necessary to dwelling to

facilitate access for timber preservative treatment by Specialist, refix floorboards, allow for upto 50% renewal as required, punch in nail heads, nail down loose boards, clean off on completion, and remove waste and debris.

305832 R DWELLING:WOODWORM TREATMENT IT 1286.84 Dwelling:Take up 20% of floorboards as necessary to dwelling to

facilitate access for and undertake woodworm treatment by approved Sub-Contractor, refix floorboards, allow for upto 50% renewal as required, punch in nail heads, nail down loose boards, clean off on completion, and remove waste and debris.

305834 R DWELLING:WOODWORM GUARANTEE IT 52.50 Dwelling:Provision of 30 year insurance backed guarantee for

woodworm treatment.

Roof Treatment 305822 R ROOF:CHEMICAL TREAT TIMBER IT 239.94 Roof:Remove and set aside Tenants personal affects and stored

items in loft area, lift and set aside all roof insulation, clean down all timbers to remove surface dust and debris, treat all accessible structural timbers with pressure spray applications of approved chemical wood preservative, leave all areas clean and tidy on completion, relay roof insulation, reinstate Tenants affects and stored items, and remove waste and debris.

305824 R ROOF:PRESERVATIVE GUARANTEE IT 52.50 Roof:Provision of 30 year insurance backed guarantee for roof

timber preservation treatment.

Page 322: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

288 Local Space Housing

305836 R ROOF:WOODWORM TIMBER IT 242.84 Roof:Remove and set aside Tenants personal affects and stored

items in loft area, lift and set aside all roof insulation, clean down all timbers to remove surface dust and debris, undertake woodworm treatment by approved Sub-Contractor to accessible structural timbers, leave all areas clean and tidy on completion, relay roof insulation, reinstate Tenants affects and stored items, and remove waste and debris.

305838 R ROOF:WOODWORM GUARANTEE IT 52.50 Roof:Provision of 30 year insurance backed guarantee for roof

timber woodworm treatment.

Deep Paste Treatment 305905 R JOIST ENDS:DEEP PASTE TREATMENT NO 22.12 Joist Ends:Take up existing floor boarding as necessary, set aside

for reuse, take out existing joist, apply deep paste treatment to one end of joist, refix joist, relay floor boarding, and remove waste and debris.

Artex Removal Removal of Artex Finishes 415021 R WALL:REMOVE ARTEX FINISHES SM 7.44 Wall:Remove artex textured coating from walls, including all making

good and and remove waste and debris.

425003 R CEILING:REMOVE ARTEX FINISH SM 9.63 Ceiling:Remove artex textured coating from ceiling, including all

making good and and remove waste and debris.

425005 U TEST:SAMPLE OF ARTEX IT 110.26 Test:Collect sample of artex texture coating removed from ceiling

or walls, arrange and test asbestos content, provide Client Representative with written report.

Specialist Treatments Graffiti Removal - External Surfaces 435501 U SURFACES :REMOVE GRAFFITI RINSE DRY SM 12.18 Surfaces:Clean existing graffiti covered surfaces with proprietary

graffiti removal or paint stripper, apply a thorough high pressure hot water rinse to remove all traces of remover or stripper, paint, debris etc., and allow to dry.

435511 R SURFACES:APPLY ANTI-GRAFFITTI PAINT SM 9.46 Surfaces:Apply anti-graffitti paint strictly in accordance with the

manufacturers instructions to vulnerable external surfaces of brickwork, concrete and timber as directed.

Bituminous Emulsion Damp Proofing Solution – External

Walls

438401 R WALLS:PREPARE 2 COATS BITUMIN DAMP PROOF SM 12.09 Walls:Brush down and prepare for and apply two coats of

bituminous emulsion damp proofing solution general surfaces of walls.

Page 323: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

289 Local Space Housing

Anti-Vandal Paint – External Pipework 438601 R PIPEWORK:PREPARE 2 COATS ANTI CLIMB TO PIPES LM 10.83 Pipework:Wire brush, prepare for and apply one coat zinc

phosphate primer and one coat of non-drying anti-vandal paint to external pipework, ne 300mm girth including brackets.

Anti-Vandal Paint – External Walls 438611 R WALLS:PREPARE APPLY 2 COATS ANTI CLIMB SM 15.89 Walls:brush down surfaces of brickwork, concrete or timber, apply one

coat of primer and one coat of non-drying anti-vandal paint strictly in accordance with the manufacturers instructions.

Mastic Asphalt Tanking etc Mastic Asphalt Tanking Damp Proof Membrane 490001 R TANKING:INSTALL ASPHALT DPM HORIZONTAL SM 49.71 Tanking:Clean off horizontal surface of concrete, prime surface with

bituminous emulsion or apply keying mix of cement:sand:slurry apply two coats of asphalt to BS 6925, tanking and damp proofing 20mm thick including all necessary internal angle fillets, make good, and remove waste and debris.

490003 R TANKING:INSTALL ASPHALT DPM RAKE FOR KEY SM 68.53 Tanking:Clean off vertical surface of concrete, prime surface with

bituminous emulsion or apply keying mix of cement:sand:slurry apply two coats of asphalt to BS 6925, tanking and damp proofing 20mm thick including all necessary internal angle fillets, make good, and remove waste and debris.

490005 R TANKING:INSTALL ASPHALT DPM VERTICAL SM 71.41 Tanking:Rake out joints of brickwork to form key, brush surface of

brickwork, prime with proprietary bitumen and rubber emulsion, apply two coats of asphalt to BS 6925, tanking and damp proofing 20mm thick including all necessary internal angle fillets, make good, and remove waste and debris.

Mastic Asphalt Flooring 114101 R FLOORING:RENEW ASPHALT NE 1SM IN PATCH IT 98.14 Flooring:Renew any floor screed with asphalt flooring to horizontal

surfaces, ne 1.00sm including removing existing screed and clear away, renew including preparing surface and applying 19mm asphalt in 2 coats to horizontal surfaces, and remove waste and debris.

114103 R FLOORING:RENEW ASPHALT OVER 1SM SM 78.36 Flooring:Renew any floor screed with asphalt flooring to horizontal

surfaces, over 1.00sm including removing existing screed and clear away, renew including preparing surface and applying 19mm asphalt in 2 coats to horizontal surfaces and remove waste and debris.

Page 324: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

290 Local Space Housing

Mould Eradication Mould Treatment 442501 R SURFACES:APPLY BACTDET AND HALOPHEN SM 13.88 Surfaces:Prepare, wash down with RLT Bactdet solution, fill in small

holes, cracks etc and apply one coat RLT Halophen solution to walls or ceilings in accordance with manufacturers directions, and apply two coats of Biocheck matt or silk emulsion to walls and ceilings.

442503 R SURFACES:ADD MGC ADDITIVE NO 6.02 Surfaces:Add sachet of MGC additive to paint or paste or wall tiling

grout as specified (per sachet).

442505 R SURFACES:REDECORATE TREATMENT SM 13.06 Surfaces:Prepare, wash down with RLT Bactdet solution, fill in small

holes, cracks etc, and apply one liberal coat of IDP by brush to any badly stained areas and apply RLT Halophen to walls or ceilings as specified and in accordance with manufacturers directions.

442507 R SURFACES:APPLY 2 COATS BIOCHECK SM 7.59 Surfaces:Prepare and apply two coats of Biocheck matt or silk

emulsion to walls or ceilings as specified and in accordance with manufacturers directions.

442509 R SURFACES:SEAL WITH HALOBOND SM 4.92 Surfaces:Prepare, rub down and wash down surfaces and apply one coat

of halobond diluted 1:4 to walls and ceilings as specified and in accordance with manufacturers directions.

442511 R SURFACES:APPLY BACTDET TO EXISTING SURFACES SM 6.37 Surfaces:Prepare, wash down existing surfaces of mould affected

paper or plaster with RLT Bactdet solution, to walls or ceilings in accordance with manufacturers directions.

442513 R SURFACES:APPLY BACTDET TO STRIPPED SURFACES SM 4.46 Surfaces:Prepare, wash down stripped surfaces of plaster with RLT

Bactdet solution, to walls or ceilings in accordance with manufacturers directions.

442515 R SURFACES:APPLY HALOPHEN SM 4.76 Surfaces:Prepare, and apply one coat RLT Halophen solution to

walls or ceilings in accordance with manufacturers directions.

442517 R WALLS:APPLY SEMPATAP SM 38.30 Surfaces:Wash down surfaces of walls and fill in small holes, cracks

etc, apply one coat of Sempatap primer to any loose paint or plaster, prepare and apply Sempatap to wall with Sempatap adhesive, cut around all sockets, switch plates, pipes, brackets and the like, fill open joints with Sempatap sealant, fix Sempatap external tape to external angles all in accordance with the manufacturer’s directions and leave ready for redecoration as specified and remove waste and debris.

442519 R FLOORS:APPLY SEMPAFLOOR SM 33.92 Floors:Wash down all floors, make good surfaces as necessary, fix

Sempafloor to floor with Sempafloor adhesive, cut around pipes and the like, fill open joints with Sempatap sealant, all in accordance with the manufacturer’s directions and leave ready for new floor covering and remove waste and debris.

Page 325: LOCAL SPACE HOUSING ASSOCIATION - hamcltd.comhamcltd.com/SoRs.pdf · item schedule rate i ... height shall mean the vertical height measured from average scaffold base ... A. Rates

LOCAL SPACE SCHEDULE OF RATES ITEM PRI DESCRIPTION UNIT RATE

291 Local Space Housing

Pest Control Pest Control 461201 U WASPS NEST:REMOVE INTERNAL OR EASY EXTERNAL NO 65.00 Wasps Nest:Remove wasps nest of any size from any internal

location or easily accessible external location including engagement of Specialist if necessary, and remove waste and debris.

461203 U WASPS NEST:REMOVE EXTERNAL NO 80.00 Wasps Nest:Remove wasps nest of any size from external location

or where access possible externally, including engagement of Specialist if necessary, and remove waste and debris.

461205 U RODENTS:MICE ERADICATION IT 60.00 Rodents:Eradicate mice internally from any type of dwelling,

including engagement of Specialist if necessary, initally attend property, lay trap bait, subsequently return and and remove waste and debris.

461209 U RODENTS:RAT ERADICATION IT 70.00 Rodents:Eradicate rats internally or within the garden confines of

any type of dwelling, including engagement of Specialist if necessary, initially attend property, lay trapbait, subsequently return and and remove waste and debris.

461217 U RODENTS:SQUIRREL ERADICATION IT 60.00 Rodents:Eradicate squirrel internally or within the garden confines

of any type of dwelling, including engagement of Specialist if necessary, initially attend property, lay trapbait, subsequently return and and remove waste and debris.

461213 U LICEANTS:ERADICATE IT 20.00 LiceAnts:Eradicate wood lice, ants or similar infestation from any

type of dwelling, including engagement of Specialist if necessary, initially attend property, provide insecticide over affected area.