lorentz ps1800

12
General Data and Sizing Tables The curve show the performance range of 4 models at 1800Wp solar array - irradiation of 6kWh/m² on a tilted surface - ambient temperature 30°C Solar tracking will improve performance by aprox 40% in summer month´s Application: - drinking water supply - livestock watering - pond management - irrigation - village water supply Controller PS1800 controlling of the pump system and monitoring of the operating states mounted at surface (no submerged electronic parts) two control inputs for well probe (dry running protection), float or pressure switches, remote control etc. automatic reset 20 minutes after well probe turns pump off protected against reverse polarity, overload and high temperature speed control, max. pump speed adjustable to reduce flow rate to approx. 30 % solar operation: integrated MPPT (Maximum Power Point Tracking) battery operation: low voltage disconnect and restart after battery has recovered max. efficiency 92 % (motor + controller) enclosure: IP 54 (sealed, weatherproof) Motor ECDRIVE 1200 HR / C brushless DC motor no electronics inside motor water filled IP68, pressure balanced, max. submersion unlimited dynamic slide bearings, material: carbon/ceramic wetted material: stainless steel (AISI 316), POM, rubber, cable drinking water approved Pump End (PE) high life expectancy none-return valve dry running protection (optional) material: stainless steel (AISI 316) Errors excepted and possible alterations without prior notice PS1800 Centrifugal Pumping Systems 0 10 20 30 40 50 60 70 80 90 15 35 55 75 95 115 135 155 Pump Lift Range SJ17-2 0-15m /50 ft SJ12-4 5- 15m / 50ft SJ8-7 15- 30m / 83ft SJ5-12 30- 65m / 215ft SJ1-25 70- 90m / 300ft Curve is based on Irradiation 6kWh/m² day, tilted surface Pump ends: SJ-xx = centrifugal pump Motor: brushless DC, maintenance free, max water temp. 25°C (80F) 30°C (90F)for systems below 1200Wp solar array LORENTZ offers standard solar pump solutions up to 230m (760ft) head and special solutions up to 750m (2500ft) head. Ask for charts meter head m³/day Ver. 080204 SJ12-4 SJ8-7 SJ5-12 Solar Pumping System / Capacity Diagram 6kWh/m²/day, 1800Wp solar array 1USG=3,8L1ImpG=4,5LSJ1-25 --> larger flow = SJ17-2

Upload: sines-france

Post on 26-Oct-2014

2.838 views

Category:

Documents


13 download

DESCRIPTION

PS1800 Centrifugal Pumping SystemsGeneral Data and Sizing TablesThe curve show the performance range of 4 models at 1800Wp solar array irradiation of 6kWh/m² on a tilted surface ambient temperature 30°CSolar tracking will improve performance by aprox 40% in summer month´s Application: - drinking water supply - livestock watering - pond management - irrigation - village water supplySolar Pumping System / Capacity Diagram 6kWh/m²/day, 1800Wp solar array90PumpSJ1-25SJ17-2 SJ12-4 SJ8-7 SJ

TRANSCRIPT

Page 1: Lorentz PS1800

General Data and Sizing Tables The curve show the performance range of 4 models at 1800Wp solar array

- irradiation of 6kWh/m² on a tilted surface - ambient temperature 30°C

Solar tracking will improve performance by aprox 40% in summer month´s Application:

- drinking water supply - livestock watering - pond management - irrigation - village water supply

Controller PS1800

• controlling of the pump system and monitoring of the operating states

• mounted at surface (no submerged electronic parts) • two control inputs for well probe (dry running protection), float

or pressure switches, remote control etc. • automatic reset 20 minutes after well probe turns pump off • protected against reverse polarity, overload and high

temperature • speed control, max. pump speed adjustable to reduce flow rate

to approx. 30 % • solar operation: integrated MPPT (Maximum Power Point

Tracking) • battery operation: low voltage disconnect and restart after

battery has recovered • max. efficiency 92 % (motor + controller) • enclosure: IP 54 (sealed, weatherproof)

Motor ECDRIVE 1200 HR / C

• brushless DC motor • no electronics inside motor • water filled • IP68, pressure balanced, max. submersion unlimited • dynamic slide bearings, material: carbon/ceramic • wetted material: stainless steel (AISI 316), POM, rubber,

cable drinking water approved

Pump End (PE)

• high life expectancy • none-return valve • dry running protection (optional) • material: stainless steel (AISI 316) Errors excepted and possible alterations without prior notice

PS1800 Centrifugal Pumping Systems

0

10

20

30

40

50

60

70

80

90

15 35 55 75 95 115 135 155

Pump Lift RangeSJ17-2 0-15m /50 ftSJ12-4 5- 15m / 50ftSJ8-7 15- 30m / 83ftSJ5-12 30- 65m / 215ft SJ1-25 70- 90m / 300ft

Curve is based onIrradiation 6kWh/m² day, tilted surfacePump ends:SJ-xx = centrifugal pump Motor:brushless DC, maintenance free, max water temp. 25°C (80F)30°C (90F)for systems below 1200Wp solar array

LORENTZ offers standard solar pump solutions up to 230m (760ft) head and special solutions up to 750m (2500ft) head. Ask for charts

met

er h

ead

m³/dayVer. 080204

SJ12-4

SJ8-7

SJ5-12

Solar Pumping System / Capacity Diagram6kWh/m²/day, 1800Wp solar array

1 USG = 3,8L1 ImpG = 4,5L

SJ1-25

--> larger flow = SJ17-2

Page 2: Lorentz PS1800

Head Metres /Ft.

kWh/m²/dayIrradiation on a tilted surface

USGPD m³/day

Direct operated PV-Pump System :Solar Pump System PS1800 C-SJ1-25C-SJ1-25

- 13,3% Generator efficiency- 1% cable loss

BERNT LORENTZ GmbH & Co.KG, Heidekoppel 16, 24558 Henstedt-Ulzburg, Germany e-mail: [email protected] Internet: www.Lorentz.deTel: +49 4193 7548-0 Fax: +49 4193 7548-29 File: Auslegungschart_LORENTZPUMP_C-SJ1-25.dwg Rev. Oct. 2007

Calculation of system performance is based on:

- non tracked PV-generator, (see ETATRACK for increasing performance)- 11h standard solar day- ambient average temperature of 30°C

80/263

90/295

92 75

Wp

1800

3 4 86

1700

1600

1500

1400

1300

1200

1100

1000

900

800

700

2

4

6

8

10

12

14

16

18

500

1000

2000

1500

2500

3000

3500

4000

4500

2200

2100

2000

1900

20

22

5000

5500

70/230

6000

650024

26

Page 3: Lorentz PS1800

www.Lorentz.de Rel. 080104

System Performance An irradiation value and the required head in meters are given for a certain solar pumping system. By connecting the point for the power output in Wp of the solar array with an irradiation value, move vertical upwards to the intersection with the required head curve, then horizontal to the left to find the daily quantity of water that can be pumped ( m³/day) Or the other way: By starting from the daily required water amount horizontally to the intersection of the required head, then vertically down to the intersection with the expected solar irradiation, then horizontally to the left to find the required output of the solar array. Instantaneous Output From the above curves, the maximum quantity of water in m³/h for a given solar array size in Wp and head in meters / ft can be found. Add at least 25% to the DC power to account for dirt, heat and other losses of the solar array. Pump Centrifugal multistage direct coupled on a LORENTZ brushless submersible motor. The pump is made from stainless steel with water lubricated rubber bearings. A non return valve is included.

Motor The LORENTZ submersible motor, type EC 1200-C is a 2 pole synchronous brushless DC motor. Slide ring bearing and ceramic trust bearings are water lubricated. The motor raw earth magnets are hermetically sealed in stainless steel and encapsulated in synthetic resin. The motor is pressure compensated and there are no practical depth limitations for submergence. No electronics are inside the motor and the entire motor is water filled. Data: Voltage: 3 X 100V electronically commutated Power: 1,6kW / 2,2HP Efficiency: 92% max Controller Mounted at surface, Well probe and float switch terminals MPPT ( max. power point tracking) Overload, temperature and reverse polarity protected Pump Speed control from 30% to full LED indicate status, pump speed water level, overload etc. 6 to 8 standard 12V modules can be connected in series. e.g. nom. Voltage 72 to 96V, max system Voltage Umax= 200V. For Systems above 1200Wp Solar array size min. 7 or 8 panels have to be wired in series.

A B C D Emax BSPSJ 1A-25 882 186 696 96 98 1 1/4" 16 kg

Pump Type Minimum Internal Diameter of Borehole Weight

4" (104mm)

Dimensions [mm]

0,0

0,5

1,0

1,5

2,0

2,5

3,0

200 400 600 800 1000 1200 1400 1600 1800DC power [W]

flow

rate

[m³/h

]

0

100

200

300

400

500

600

700

flow

rate

[US

gal/h

]

PS1800 C-SJ1-25 (Item No. 1156 ) for Solar Operation(Solar generator: Nominal voltage 72 to 96 V DC, open circuit voltage max. 200V DC)

70 m / 230 ft

80 m / 263 ft90 m / 295 ft

Instantaneous Output Average Values

Page 4: Lorentz PS1800

kWh/m²/dayIrradiation on a tilted surface

Direct operated PV-Pump System :Solar Pump System PS1800 C-SJ5-12C-SJ5-12

- 1% cable loss

BERNT LORENTZ GmbH & Co.KG, Heidekoppel 16, 24558 Henstedt-Ulzburg, Germany e-mail: [email protected] Internet: www.Lorentz.deTel: +49 4193 7548-0 Fax: +49 4193 7548-29 File: Auslegungschart_LORENTZPUMP_C-SJ5-12.dwg Rev. Jul. 2007

Calculation of system performance is based on:

- non tracked PV-generator, (see ETATRACK for increasing performance)- 11h standard solar day- ambient average temperature of 30°C

Head Metres /Ft.USGPD m³/day

92 75

Wp

1800

3 4 86

17001600150014001300120011001000900800700

10

20

30

50

2000

4000

6000

8000

40/132

60/197

50/165

2200210020001900

11000

70/230

5

15

25

35

1000

3000

5000

7000

9000

4010000

4512000

13000

Page 5: Lorentz PS1800

www.Lorentz.de Rel. 081114

System Performance An irradiation value and the required head in meters are given for a certain solar pumping system. By connecting the point for the power output in Wp of the solar array with an irradiation value, move vertical upwards to the intersection with the required head curve, then horizontal to the left to find the daily quantity of water that can be pumped ( m³/day) Or the other way: By starting from the daily required water amount horizontally to the intersection of the required head, then vertically down to the intersection with the expected solar irradiation, then horizontally to the left to find the required output of the solar array. Instantaneous Output From the above curves, the maximum quantity of water in m³/h for a given solar array size in Wp and head in meters / ft can be found. Add at least 25% to the DC power to account for dirt, heat and other losses of the solar array. Pump Centrifugal multistage direct coupled on a LORENTZ brushless submersible motor. The pump is made from stainless steel with water lubricated rubber bearings. A non return valve is included.

Motor The LORENTZ submersible motor, type EC 1200-C is a 2 pole synchronous brushless DC motor. Slide ring bearing and ceramic trust bearings are water lubricated. The motor raw earth magnets are hermetically sealed in stainless steel and encapsulated in synthetic resin. The motor is pressure compensated and there are no practical depth limitations for submergence. No electronics are inside the motor and the entire motor is water filled. Data: Voltage: 3 X 100V electronically commutated Power: 1,6kW / 2,2HP Efficiency: 92% max Controller Mounted at surface, Well probe and float switch terminals MPPT ( max. power point tracking) Overload, temperature and reverse polarity protected Pump Speed control from 30% to full LED indicate status, pump speed water level, overload etc. 6 to 8 standard 12V modules can be connected in series. e.g. nom. Voltage 72 to 96V, max system Voltage Umax= 200V. For Systems above 1200Wp Solar array size min. 7 or 8 panels have to be wired in series.

A B C D Emax BSPSJ 5A-12 612 186 426 96 98 1 1/2" 13,5 kg

Pump Type Minimum Internal Diameter of Borehole Weight

4" (104mm)

Dimensions [mm]

0,0

0,5

1,0

1,5

2,0

2,5

3,0

3,5

4,0

4,5

5,0

5,5

6,0

6,5

0 200 400 600 800 1000 1200 1400 1600 1800DC Power [W]

flow

rate

[m³/h

]

0

200

400

600

800

1000

1200

1400

1600

flow

rate

[US

gal/h

]

PS1800 C-SJ5-12 (Item No. 1163) for Solar Operation(Solar generator: Nominal voltage 72 to 96 V DC, open circuit voltage max. 200V DC)

System Performance

70 m / 230 ft

60 m / 197 ft

50 m / 164 ft

40 m / 131 ft

30 m / 100 ft

Instantaneous Output Average Values

Page 6: Lorentz PS1800

Head Metres /Ft.

kWh/m²/dayIrradiation on a tilted surface

USGPD m³/day

Direct operated PV-Pump System :Solar Pump System PS1800 C-SJ8-7C-SJ8-7

- 1% cable loss

BERNT LORENTZ GmbH & Co.KG, Heidekoppel 16, 24558 Henstedt-Ulzburg, Germany Internet: www.Lorentz.deTel: +49 4193 7548-0 Fax: +49 4193 7548-29 File: Auslegungschart_LORENTZPUMP_C-SJ8-7.dwg Rev. Aug. 2007

Calculation of system performance is based on:

- non tracked PV-generator, (see ETATRACK for increasing performance)- 11h standard solar day- ambient average temperature of 30°C

10/33

15/49.5

92 75

Wp

1800

3 4 86

17001600150014001300120011001000900800700

10

20

30

40

50

60

70

5000

10000

15000

20/66

25/82.5

80

90

100

110

120

130

20000

25000

30000

30/98

2200210020001900

Page 7: Lorentz PS1800

www.Lorentz.de Rel. 070820

System Performance An irradiation value and the required head in meters are given for a certain solar pumping system. By connecting the point for the power output in Wp of the solar array with an irradiation value, move vertical upwards to the intersection with the required head curve, then horizontal to the left to find the daily quantity of water that can be pumped ( m³/day) Or the other way: By starting from the daily required water amount horizontally to the intersection of the required head, then vertically down to the intersection with the expected solar irradiation, then horizontally to the left to find the required output of the solar array. Instantaneous Output From the above curves, the maximum quantity of water in m³/h for a given solar array size in Wp and head in meters / ft can be found. Add at least 25% to the DC power to account for dirt, heat and other losses of the solar array. Pump Centrifugal multistage direct coupled on a LORENTZ brushless submersible motor. The pump is made from stainless steel with water lubricated rubber bearings. A non return valve is included.

Motor The LORENTZ submersible motor, type EC 1200-C is a 2 pole synchronous brushless DC motor. Slide ring bearing and ceramic trust bearings are water lubricated. The motor raw earth magnets are hermetically sealed in stainless steel and encapsulated in synthetic resin. The motor is pressure compensated and there are no practical depth limitations for submergence. No electronics are inside the motor and the entire motor is water filled. Data: Voltage: 3 X 100V electronically commutated Power: 1,6kW / 2,2HP Efficiency: 92% max Controller Mounted at surface, Well probe and float switch terminals MPPT ( max. power point tracking) Overload, temperature and reverse polarity protected Pump Speed control from 30% to full LED indicate status, pump speed water level, overload etc. 6 to 8 standard 12V modules can be connected in series. e.g. nom. Voltage 72 to 96V, max system Voltage Umax= 200V. For Systems above 1200Wp Solar array size min. 7 or 8 panels have to be wired in series.

0

2

4

6

8

10

12

14

0 200 400 600 800 1000 1200 1400 1600 1800DC power [W]

flow

rate

[m³/h

]

0

500

1000

1500

2000

2500

3000

3500

flow

rate

[US

gal/h

]

PS1800 C-SJ8-7 (Item No. 1169) for Solar Operation(Solar generator: Nominal voltage 72 to 96 V DC, open circuit voltage max. 200V DC)

15 m / 49 ft

20 m / 66 ft

25 m / 82 ft

30 m / 98 ft

10 m / 33 ftInstantaneous Output Average Values

A B C D Emax BSPSJ 8A-7 685 186 415 96 98 2" 13,5 kg

Pump Type Minimum Internal Diameter of Borehole Weight

4" (104mm)

Dimensions [mm]

Page 8: Lorentz PS1800

Head Metres /Ft.

kWh/m²/dayIrradiation on a tilted surface

USGPD m³/day

Direct operated PV-Pump System :Solar Pump System PS1800 C-SJ12-4C-SJ12-4

- 1% cable loss

BERNT LORENTZ GmbH & Co.KG, Heidekoppel 16, 24558 Henstedt-Ulzburg, Germany Internet: www.Lorentz.deTel: +49 4193 7548-0 Fax: +49 4193 7548-29 File: Auslegungschart_LORENTZPUMP_C-SJ12-4.dwg Rev. Aug. 2007

Calculation of system performance is based on:

- non tracked PV-generator, (see ETATRACK for increasing performance)- 11h standard solar day- ambient average temperature of 30°C

12.5/41

10/33

7.5/25

15/49.5

92 75

Wp

1800

3 4 86

17001600150014001300120011001000900800700

20

40

60

80

100

120

140

160

180

200

5000

10000

20000

15000

25000

30000

35000

40000

45000

50000

2200210020001900

Page 9: Lorentz PS1800

www.Lorentz.de Rel. 070823

System Performance An irradiation value and the required head in meters are given for a certain solar pumping system. By connecting the point for the power output in Wp of the solar array with an irradiation value, move vertical upwards to the intersection with the required head curve, then horizontal to the left to find the daily quantity of water that can be pumped ( m³/day) Or the other way: By starting from the daily required water amount horizontally to the intersection of the required head, then vertically down to the intersection with the expected solar irradiation, then horizontally to the left to find the required output of the solar array. Instantaneous Output From the above curves, the maximum quantity of water in m³/h for a given solar array size in Wp and head in meters / ft can be found. Add at least 25% to the DC power to account for dirt, heat and other losses of the solar array. Pump Centrifugal multistage direct coupled on a LORENTZ brushless submersible motor. The pump is made from stainless steel with water lubricated rubber bearings. A non return valve is included.

Motor The LORENTZ submersible motor, type EC 1200-C is a 2 pole synchronous brushless DC motor. Slide ring bearing and ceramic trust bearings are water lubricated. The motor raw earth magnets are hermetically sealed in stainless steel and encapsulated in synthetic resin. The motor is pressure compensated and there are no practical depth limitations for submergence. No electronics are inside the motor and the entire motor is water filled. Data: Voltage: 3 X 100V electronically commutated Power: 1,6kW / 2,2HP Efficiency: 92% max Controller Mounted at surface, Well probe and float switch terminals MPPT ( max. power point tracking) Overload, temperature and reverse polarity protected Pump Speed control from 30% to full LED indicate status, pump speed water level, overload etc. 6 to 8 standard 12V modules can be connected in series. E.g. nom. Voltage 72 to 96V, max system Voltage Umax= 200V

0

2

4

6

8

10

12

14

16

18

20

22

0 200 400 600 800 1000 1200 1400 1600 1800DC power [W]

flow

rate

[m³/h

]

0

500

1000

1500

2000

2500

3000

3500

4000

4500

5000

5500

flow

rate

[US

gal/h

]

PS1800 C-SJ12-4 (Item No. 1217 ) for Solar Operation(Solar generator: Nominal voltage 72 to 96 V DC, open circuit voltage max. 200V DC)

10 m / 33 ft

15 m / 49 ft

12,5 m / 41 ft

7,5m / 25 ft

20 m / 66 ft

Instantaneous Output Average Values

A B C D Emax BSPSJ 12A-4 666 186 480 96 98 2" 13 kg

Pump Type Minimum Internal Diameter of Borehole Weight

4" (104mm)

Dimensions [mm]

Page 10: Lorentz PS1800

Head Metres /Ft.

kWh/m²/dayIrradiation on a tilted surface

USGPD m³/day

Direct operated PV-Pump System :Solar Pump System PS1800 C-SJ17-2C-SJ17-2

- 13,3% Generator efficiency- 1% cable loss

BERNT LORENTZ GmbH & Co.KG, Heidekoppel 16, 24558 Henstedt-Ulzburg, Germany Internet: www.Lorentz.deTel: +49 4193 7548-0 Fax: +49 4193 7548-29 File: Auslegungschart_LORENTZPUMP_C-SJ17-2.dwg Rev. Aug. 2007

Calculation of system performance is based on:

- non tracked PV-generator, (see ETATRACK for increasing performance)- 11h standard solar day- ambient average temperature of 30°C

10/33

12.5/41

92 75

Wp

1800

3 4 86

1700

1600

1500

1400

1300

1200

1100

1000

900

800

700

20

40

60

80

100

120

140

160

180

5000

10000

20000

15000

25000

30000

35000

40000

45000

15/49

2200

2100

2000

1900

200

220

50000

55000 7.5/25

Page 11: Lorentz PS1800

www.Lorentz.de Rel. 081218

System Performance An irradiation value and the required head in meters are given for a certain solar pumping system. By connecting the point for the power output in Wp of the solar array with an irradiation value, move vertical upwards to the intersection with the required head curve, then horizontal to the left to find the daily quantity of water that can be pumped ( m³/day) Or the other way: By starting from the daily required water amount horizontally to the intersection of the required head, then vertically down to the intersection with the expected solar irradiation, then horizontally to the left to find the required output of the solar array. Instantaneous Output From the above curves, the maximum quantity of water in m³/h for a given solar array size in Wp and head in meters / ft can be found. Add at least 25% to the DC power to account for dirt, heat and other losses of the solar array. Pump Centrifugal multistage direct coupled on a LORENTZ brushless submersible motor. The pump is made from stainless steel with water lubricated rubber bearings. A non return valve is included.

Motor The LORENTZ submersible motor, type EC 1200-C is a 2 pole synchronous brushless DC motor. Slide ring bearing and ceramic trust bearings are water lubricated. The motor raw earth magnets are hermetically sealed in stainless steel and encapsulated in synthetic resin. The motor is pressure compensated and there are no practical depth limitations for submergence. No electronics are inside the motor and the entire motor is water filled. Data: Voltage: 3 X 100V electronically commutated Power: 1,6kW / 2,2HP Efficiency: 92% max Controller Mounted at surface, Well probe and float switch terminals MPPT ( max. power point tracking) Overload, temperature and reverse polarity protected Pump Speed control from 30% to full LED indicate status, pump speed water level, overload etc. 6 to 8 standard 12V modules can be connected in series. E.g. nom. Voltage 72 to 96V, max system Voltage Umax= 200V Systems above 1200Wp require 8 panels wired in series for nom 96V

0

2

4

6

8

10

12

14

16

18

20

22

24

0 200 400 600 800 1000 1200 1400 1600 1800DC power [W]

flow

rate

[m³/h

]

0

500

1000

1500

2000

2500

3000

3500

4000

4500

5000

5500

6000

flow

rate

[US

gal/h

]

PS1800 C-SJ17-2 (Item No. 1168 ) for Solar Operation(Solar generator: Nominal voltage 96 V DC, open circuit voltage max. 200V DC)

10 m / 33 ft

15 m / 49 ft

12,5 m / 41 ft

7,5m / 25 ftInstantaneous Output Average Values

A B C D Emax BSPSJ 17-2 578 186 392 98 128 2 1/2" 15,5 kg

Pump Type Minimum Internal Diameter of Borehole Weight

5" (130mm)

Dimensions [mm]

Page 12: Lorentz PS1800

Depth of Well

Tank Height

Well to Basin

Cable Length

Trans. Pipe Diameter

Riser Pipe Diameter

Well Diameter

Trans. Pipeline Length

Static Level

Drawdown

Pump Intake Depth