Page 1 / 7. 30-09-2013 Order No: 52486835 Eqiup No: 10013463 Field Report. MT 022 Magnetic Particle Examination Division for Inspection and Testing Installation Maersk Giant. Period of examination/Date Technician (Init.) Certificate No. Assistant (Init.) Certificate No. 13-09-2013 to 27-09-2013 JAC 0955- N2 Client Owner Maersk Drilling Norway. Object Material Jacking gear frame 3B3. FE Tag Number Port side leg. Supplementary information (without liability, see at the foot) Weld preparation Other Heat-treated Time of examination X Y U V K I Fillet Yes No Hours after weld. Welding process 121 131 135 136 141 Other Man.elec. 111 Sub.arc. MIG MAG Fluxcored wire TIG Surface condition Reinforcement Fine Smooth General Primer coated As welded Ground Examination procedure Other EN 1290 ASME V M-CPH-1171-00378_EN. Current magnetizing Yoke Coil magnetizing Permanent magnet Test bench S S max.= mm I eff.= Amp. S Type Tiede S max.= 150mm S Current AC DC Number of turns = I = Amp. S S N S = mm Lifting Power = N Longit. Amp. Circular Amp. x turns Reg. No. Reg. No. 0101. Reg. No. Reg. No. Type of prods Other Arc burns ground out De-magnetized after examination Steel Copper Yes No Yes No Water/black Kerosine/black Background Magnetic ink Water/fluo. Kerosine//fluo. Dry powder White Ground Non-treated Field strength kA/m Other Lighting Oerstedm. value Oe CASTROL STRIP White UV-lamp No. Magnetized for Object temperature Other Longitudinal indications Transverse indications Indications in any direction Ambient Acceptance criteria Incl. visual exam. Other EN 1291, level ASME VIII.1 DS 412, Weld class M-CPH-1171-00378_EN. Extent of examination MT inspection at jacking gear house 3B3 inside on welds + HAZ. Three areas outside the jacking gear house welds +HAZ. There is four areas there is not inspected, there is still paint on. Results of examination Indication was found in six areas. See below. Repairs marked Check after grinding Enclosures Enclosures On object Repair rechecked On sketch Stamped mk: Appr. NDT Operator. Appr. by owner/representative Appr. by certification authority Date/Signature 30-09-2013.Jan Christensen Date/Signature Date/Signature Supplementary information: The grey fields supply available, relevant information for guidance only. The giving of such information in this Field Report should not be considered as verification of its accuracy.

Upload: duongnhi

Post on 09-Sep-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Magnetic Particle Examination Order No: 52486835 … · Division for Inspection and Testing Page 1 / 7. 30-09-2013 Order No: 52486835 Eqiup No: 10013463 Field Report. MT 022 Magnetic

Page 1 / 7. 30-09-2013

Order No: 52486835 Eqiup No: 10013463

Field Report. MT 022

Magnetic Particle Examination Division for Inspection and Testing

Installation

Maersk Giant. Period of examination/Date Technician (Init.) Certificate No. Assistant (Init.) Certificate No.

13-09-2013 to 27-09-2013 JAC 0955- N2 Client

Owner Maersk Drilling Norway.

Object

Material

Jacking gear frame 3B3. FE Tag Number

Port side leg. Supplementary information (without liability, see at the foot)

Weld preparation Other Heat-treated Time of examination

X Y U V K I Fillet Yes No Hours after weld.

Welding process 121 131 135 136 141 Other

Man.elec. 111 Sub.arc. MIG MAG Fluxcored wire TIG Surface condition

Reinforcement

Fine Smooth General Primer coated As welded Ground

Examination procedure

Other

EN 1290 ASME V

M-CPH-1171-00378_EN.

Current magnetizing Yoke Coil magnetizing Permanent magnet Test bench

S

S max.= mm

I eff.= Amp. S

Type Tiede S max.= 150mm

S

Current

AC

DC

Number of turns =

I = Amp. S

SN

S = mm

Lifting Power =

N

Longit. Amp.

Circular Amp. x turns

Reg. No. Reg. No. 0101. Reg. No. Reg. No.

Type of prods Other Arc burns ground out De-magnetized after examination

Steel Copper Yes No Yes No

Water/black Kerosine/black Background

Magnetic ink Water/fluo. Kerosine//fluo. Dry powder

White Ground Non-treated

Field strength kA/m Other Lighting

Oerstedm. value Oe CASTROL STRIP

White UV-lamp No.

Magnetized for Object temperature Other

Longitudinal indications

Transverse indications

Indications in any direction Ambient Acceptance criteria Incl. visual exam. Other

EN 1291, level ASME VIII.1

DS 412, Weld class M-CPH-1171-00378_EN. Extent of examination

MT inspection at jacking gear house 3B3 inside on welds + HAZ. Three areas outside the jacking gear house welds +HAZ.

There is four areas there is not inspected, there is still paint on.

Results of examination

Indication was found in six areas. See below.

Repairs marked Check after grinding Enclosures Enclosures

On object Repair rechecked

On sketch Stamped mk: Appr. NDT Operator. Appr. by owner/representative Appr. by certification authority

Date/Signature 30-09-2013.Jan Christensen

Date/Signature Date/Signature

Supplementary information: The grey fields supply available, relevant information for guidance only. The giving of such information in this Field Report should not be considered as verification of its accuracy.

Page 2: Magnetic Particle Examination Order No: 52486835 … · Division for Inspection and Testing Page 1 / 7. 30-09-2013 Order No: 52486835 Eqiup No: 10013463 Field Report. MT 022 Magnetic

Page 2 / 7. 30-09-2013

Order No: 52486835 Eqiup No: 10013463

Field Report. MT 022

Magnetic Particle Examination Division for Inspection and Testing

Page 3: Magnetic Particle Examination Order No: 52486835 … · Division for Inspection and Testing Page 1 / 7. 30-09-2013 Order No: 52486835 Eqiup No: 10013463 Field Report. MT 022 Magnetic

Page 3 / 7. 30-09-2013

Order No: 52486835 Eqiup No: 10013463

Field Report. MT 022

Magnetic Particle Examination Division for Inspection and Testing

Indication No.1

45 mm

23 mm

75 mm

Indication No. 1 is 145 mm.

Indication No.2

Indication No.3

Indication No.4

Indication No.5

Indication No.6

Page 4: Magnetic Particle Examination Order No: 52486835 … · Division for Inspection and Testing Page 1 / 7. 30-09-2013 Order No: 52486835 Eqiup No: 10013463 Field Report. MT 022 Magnetic

Page 4 / 7. 30-09-2013

Order No: 52486835 Eqiup No: 10013463

Field Report. MT 022

Magnetic Particle Examination Division for Inspection and Testing

Indication No.2 is 200 mm.

Indication No. 3 is 20 mm.

Page 5: Magnetic Particle Examination Order No: 52486835 … · Division for Inspection and Testing Page 1 / 7. 30-09-2013 Order No: 52486835 Eqiup No: 10013463 Field Report. MT 022 Magnetic

Page 5 / 7. 30-09-2013

Order No: 52486835 Eqiup No: 10013463

Field Report. MT 022

Magnetic Particle Examination Division for Inspection and Testing

Indication No. 4 is 28 mm.

Indication No. 5 is 20 mm.

Page 6: Magnetic Particle Examination Order No: 52486835 … · Division for Inspection and Testing Page 1 / 7. 30-09-2013 Order No: 52486835 Eqiup No: 10013463 Field Report. MT 022 Magnetic

Page 6 / 7. 30-09-2013

Order No: 52486835 Eqiup No: 10013463

Field Report. MT 022

Magnetic Particle Examination Division for Inspection and Testing

Indication No. 6 is 20 mm.

Areas with paint on.

Not MT. Tested.

Page 7: Magnetic Particle Examination Order No: 52486835 … · Division for Inspection and Testing Page 1 / 7. 30-09-2013 Order No: 52486835 Eqiup No: 10013463 Field Report. MT 022 Magnetic

Page 7 / 7. 30-09-2013

Order No: 52486835 Eqiup No: 10013463

Field Report. MT 022

Magnetic Particle Examination Division for Inspection and Testing

Areas with paint on.

Not MT. Tested.