magnetic particle examination order no: 52486835 … · division for inspection and testing page 1...
TRANSCRIPT
![Page 1: Magnetic Particle Examination Order No: 52486835 … · Division for Inspection and Testing Page 1 / 7. 30-09-2013 Order No: 52486835 Eqiup No: 10013463 Field Report. MT 022 Magnetic](https://reader031.vdocuments.net/reader031/viewer/2022022609/5b94420809d3f2130d8c57c6/html5/thumbnails/1.jpg)
Page 1 / 7. 30-09-2013
Order No: 52486835 Eqiup No: 10013463
Field Report. MT 022
Magnetic Particle Examination Division for Inspection and Testing
Installation
Maersk Giant. Period of examination/Date Technician (Init.) Certificate No. Assistant (Init.) Certificate No.
13-09-2013 to 27-09-2013 JAC 0955- N2 Client
Owner Maersk Drilling Norway.
Object
Material
Jacking gear frame 3B3. FE Tag Number
Port side leg. Supplementary information (without liability, see at the foot)
Weld preparation Other Heat-treated Time of examination
X Y U V K I Fillet Yes No Hours after weld.
Welding process 121 131 135 136 141 Other
Man.elec. 111 Sub.arc. MIG MAG Fluxcored wire TIG Surface condition
Reinforcement
Fine Smooth General Primer coated As welded Ground
Examination procedure
Other
EN 1290 ASME V
M-CPH-1171-00378_EN.
Current magnetizing Yoke Coil magnetizing Permanent magnet Test bench
S
S max.= mm
I eff.= Amp. S
Type Tiede S max.= 150mm
S
Current
AC
DC
Number of turns =
I = Amp. S
SN
S = mm
Lifting Power =
N
Longit. Amp.
Circular Amp. x turns
Reg. No. Reg. No. 0101. Reg. No. Reg. No.
Type of prods Other Arc burns ground out De-magnetized after examination
Steel Copper Yes No Yes No
Water/black Kerosine/black Background
Magnetic ink Water/fluo. Kerosine//fluo. Dry powder
White Ground Non-treated
Field strength kA/m Other Lighting
Oerstedm. value Oe CASTROL STRIP
White UV-lamp No.
Magnetized for Object temperature Other
Longitudinal indications
Transverse indications
Indications in any direction Ambient Acceptance criteria Incl. visual exam. Other
EN 1291, level ASME VIII.1
DS 412, Weld class M-CPH-1171-00378_EN. Extent of examination
MT inspection at jacking gear house 3B3 inside on welds + HAZ. Three areas outside the jacking gear house welds +HAZ.
There is four areas there is not inspected, there is still paint on.
Results of examination
Indication was found in six areas. See below.
Repairs marked Check after grinding Enclosures Enclosures
On object Repair rechecked
On sketch Stamped mk: Appr. NDT Operator. Appr. by owner/representative Appr. by certification authority
Date/Signature 30-09-2013.Jan Christensen
Date/Signature Date/Signature
Supplementary information: The grey fields supply available, relevant information for guidance only. The giving of such information in this Field Report should not be considered as verification of its accuracy.
![Page 2: Magnetic Particle Examination Order No: 52486835 … · Division for Inspection and Testing Page 1 / 7. 30-09-2013 Order No: 52486835 Eqiup No: 10013463 Field Report. MT 022 Magnetic](https://reader031.vdocuments.net/reader031/viewer/2022022609/5b94420809d3f2130d8c57c6/html5/thumbnails/2.jpg)
Page 2 / 7. 30-09-2013
Order No: 52486835 Eqiup No: 10013463
Field Report. MT 022
Magnetic Particle Examination Division for Inspection and Testing
![Page 3: Magnetic Particle Examination Order No: 52486835 … · Division for Inspection and Testing Page 1 / 7. 30-09-2013 Order No: 52486835 Eqiup No: 10013463 Field Report. MT 022 Magnetic](https://reader031.vdocuments.net/reader031/viewer/2022022609/5b94420809d3f2130d8c57c6/html5/thumbnails/3.jpg)
Page 3 / 7. 30-09-2013
Order No: 52486835 Eqiup No: 10013463
Field Report. MT 022
Magnetic Particle Examination Division for Inspection and Testing
Indication No.1
45 mm
23 mm
75 mm
Indication No. 1 is 145 mm.
Indication No.2
Indication No.3
Indication No.4
Indication No.5
Indication No.6
![Page 4: Magnetic Particle Examination Order No: 52486835 … · Division for Inspection and Testing Page 1 / 7. 30-09-2013 Order No: 52486835 Eqiup No: 10013463 Field Report. MT 022 Magnetic](https://reader031.vdocuments.net/reader031/viewer/2022022609/5b94420809d3f2130d8c57c6/html5/thumbnails/4.jpg)
Page 4 / 7. 30-09-2013
Order No: 52486835 Eqiup No: 10013463
Field Report. MT 022
Magnetic Particle Examination Division for Inspection and Testing
Indication No.2 is 200 mm.
Indication No. 3 is 20 mm.
![Page 5: Magnetic Particle Examination Order No: 52486835 … · Division for Inspection and Testing Page 1 / 7. 30-09-2013 Order No: 52486835 Eqiup No: 10013463 Field Report. MT 022 Magnetic](https://reader031.vdocuments.net/reader031/viewer/2022022609/5b94420809d3f2130d8c57c6/html5/thumbnails/5.jpg)
Page 5 / 7. 30-09-2013
Order No: 52486835 Eqiup No: 10013463
Field Report. MT 022
Magnetic Particle Examination Division for Inspection and Testing
Indication No. 4 is 28 mm.
Indication No. 5 is 20 mm.
![Page 6: Magnetic Particle Examination Order No: 52486835 … · Division for Inspection and Testing Page 1 / 7. 30-09-2013 Order No: 52486835 Eqiup No: 10013463 Field Report. MT 022 Magnetic](https://reader031.vdocuments.net/reader031/viewer/2022022609/5b94420809d3f2130d8c57c6/html5/thumbnails/6.jpg)
Page 6 / 7. 30-09-2013
Order No: 52486835 Eqiup No: 10013463
Field Report. MT 022
Magnetic Particle Examination Division for Inspection and Testing
Indication No. 6 is 20 mm.
Areas with paint on.
Not MT. Tested.
![Page 7: Magnetic Particle Examination Order No: 52486835 … · Division for Inspection and Testing Page 1 / 7. 30-09-2013 Order No: 52486835 Eqiup No: 10013463 Field Report. MT 022 Magnetic](https://reader031.vdocuments.net/reader031/viewer/2022022609/5b94420809d3f2130d8c57c6/html5/thumbnails/7.jpg)
Page 7 / 7. 30-09-2013
Order No: 52486835 Eqiup No: 10013463
Field Report. MT 022
Magnetic Particle Examination Division for Inspection and Testing
Areas with paint on.
Not MT. Tested.