Mains controller

Installation and operating guide

Page 2: Manual - Mains Controller (50035400_A)

8/9/2019 Manual - Mains Controller (50035400_A)

http://slidepdf.com/reader/full/manual-mains-controller-50035400a 2/11

astralTM mains controllers are available in 1 and 2 gangversions and are suitable for flush or surface mounting inBS wall boxes with a minimum internal depth of 35mm andshould be mounted in dry indoor locations only.

A mains controller can provide on/off control over switchesand in addition on/off and dimming control over dimmers tooperate together as a group. Alternatively it can be used to

control a scene where the user configured light levels arerecalled to set a required lighting mood.

Up to 64 different switches and dimmers maybe controlled byeach mains controller. A 2 gang mains controller can control 2groups or scenes.

The mains controller also allows activation of the astralsystem HOLIDAY MODE feature and a system ALL-OFF functionvia its default functionality.

The mains controller also incorporates command statusindicators giving visual indication and confirmation thatany commands to other switches and dimmers have beensuccessfully received. There is also a night locator feature tohelp find the controller in the dark.

Always follow the manufacturer’s advice when using powertools, steps, ladders etc. and wear appropriate protectiveequipment such as safety goggles when drilling holes. Beforedrilling holes in walls, check for hidden electricity cables andwater pipes, and use a cable/pipe locater if in doubt.

DANGER 230 VOLTS

Always disconnect the electricity supply before commencingany work on the installation of devices.

This device should be installed by a competent personor a qualified electrician in accordance with the device’sinstallation instructions and the appropriate current nationalwiring regulations.

It is essential that all connections are made as instructed, thatcables are not stressed and that terminals are fully tightened.

The mains supply to this device must be protected by a 10Atype B or type C MCB.

MAINS CONTROLLER INSTALLATION AND OPERATING GUIDE  2

IntroductionMAINS CONTROLLER INSTALLATION AND OPERATING GUIDE  3

Safety

GROUP CONTROL AND DIMMING

When turning on a group, dimmers

will turn on at the light level they

were set to before they were

turned off.

The light levels of all dimmers in a

group will align to the same level

after any dimming operation ends.

SCENE CONTROL AND DIMMING

When turning on dimmers in a

scene they will always go to their

programmed light level for the

scene.

Dimming of all dimmers in a scene

will maintain any difference in light

level after dimming stops. The light

levels will not align.

Page 3: Manual - Mains Controller (50035400_A)

8/9/2019 Manual - Mains Controller (50035400_A)

http://slidepdf.com/reader/full/manual-mains-controller-50035400a 3/11

Program button

and indicator

Operation button

and status indicator

Operation button

and status indicator

Operation buttons

and status indicators

Program button

and indicator

Inc/Asc Exc/Dis

MAINS CONTROLLER INSTALLATION AND OPERATING GUIDE  4

Operation

Each channel of the mains

controller is capable of controlling

a group or scene containing up

to 64 other switches or dimmers.

However the product cannot

control more than 64 other

switches and dimmers in total.

2 GANG PRODUCTS

A 2 gang mains controller has2 sets of operation buttons and

status indicators, one for each

channel.MODULE WITH

FASCIA REMOVED

Short press ON / SET SCENE

Long press DIM UP

Fascia release clip

Short press OFF

Long press DIM DOWN

Inc/Asc Exc/Dis

1 2

Each channel button on the mains

controller includes a command

status that illuminates after each

operation as follows:

FLASH RED 1 TIME 

Device not included in the system

FLASH GREEN 3 TIMES

Command received by all target switches and dimmers

FLASH RED 3 TIMES

Command not received by all target switches and dimmers

BLUE LOW INTENSITYNight locator feature, visible in low light conditions

SWITCHES BETWEEN HIGH AND LOW LEVEL BLUE EVERY SECOND

Holiday mode active

MAINS CONTROLLER INSTALLATION AND OPERATING GUIDE  5

Status indicators

Page 4: Manual - Mains Controller (50035400_A)

8/9/2019 Manual - Mains Controller (50035400_A)

http://slidepdf.com/reader/full/manual-mains-controller-50035400a 4/11

The default functionality will

be over-ridden as soon as any

association is created on

channel 1 of the product.

To restore the default functionality,

delete all associations on

channel 1, (see pages 14 - 15).

ACTIVATING HOLIDAY MODE

To activate holiday mode press

and hold down the bottom button

on channel 1 for over 1 second.

DE-ACTIVATING HOLIDAY MODE

Holiday mode is cancelled either

by a short press the bottom part

of the rocker on channel 1 or by

operating any switch or dimmer in

the system.

ALL-OFF

The system ALL-OFF command is

activated by a long press of the

top part of the rocker on channel 1.

MAINS CONTROLLER INSTALLATION AND OPERATING GUIDE  6

Holiday mode

Holiday mode is an occupation

simulation feature built into the

astralTM lighting control system

products.

When holiday mode is activated,

astralTM switches and dimmers

will automatically simulate their

operation over the previous 24

hour period. This will continue untilholiday mode is cancelled.

ACTIVATING HOLIDAY MODE

Holiday mode can only be activated

using the default functionality on

channel 1 on an astralTM mains or

battery controller.

CANCELLING HOLIDAY MODE

Holiday mode can be cancelled

using either the default functionality

on channel 1 of a mains or battery

controller or by operating any

astralTM switch or dimmer.

System ALL-OFF

Long press

System ALL-OFF

Long press

Holiday mode

Long press ON

Short press OFF

Holiday mode

Long press ON

Short press OFF

MAINS CONTROLLER INSTALLATION AND OPERATING GUIDE  7

Mains controller default functionality

1 2

1

Page 5: Manual - Mains Controller (50035400_A)

8/9/2019 Manual - Mains Controller (50035400_A)

http://slidepdf.com/reader/full/manual-mains-controller-50035400a 5/11

The mains controller is suitable for

use with astralTM dimmer fascias

only. Only fit a 1 gang fascia to a

1 gang mains controller and a 2

gang fascia to a 2 gang mains

controller.

FITTING THE FASCIA

Holding the fascia at a slight angle

to the module, locate the 2 hooks

on the back of the fascia into the

holes on the top of the module.

Gently push the fascia up and then

push home along the bottom edge

until the clip snaps home securing

the fascia in position.

 

REMOVING THE FASCIA

Press the release clip in the bottom

edge to the module and carefully

release the fascia at the bottom edge.

Pull the fascia downwards to

disengage the 2 hooks before fully

removing the fascia.

N 2 1L

N

L

Supply

MAINS CONTROLLER INSTALLATION AND OPERATING GUIDE  8

Fitting and removing fasciasMAINS CONTROLLER INSTALLATION AND OPERATING GUIDE  9

Installation

1 Strip back the outer cable sheath

and trim the inner cables to

length. Carefully strip the inner

cable insulation to expose 8mm

of wire.

2 Connect the Live and Neutral

cables to the switch as shown in

the diagram:

  Live = brown  Neutral = blue

  NOTE Some countries and

existing installations may also

use the following cable colours:

  Live = red

  Neutral = black

3 Any earth wires must be suitably

terminated and fitted with

yellow/green insulating sleeving.

4 Carefully push the wired unit into

the back box, ensuring cables are

not trapped or pinched.

5 Secure the device to the wall box

using the fixing screws provided.

  NOTE Do not over tighten the

fixing screws as this may cause

damage or distortion to the

device that could impair normal

operation or fitting the fascia.

DO NOT USE ELECTRIC SCREWDRIVERS

OR POWER TOOLS

220-240V

50Hz

IMPORTANT The mains supply must

be protected by a 10A class B or

C MCB.

Page 6: Manual - Mains Controller (50035400_A)

8/9/2019 Manual - Mains Controller (50035400_A)

http://slidepdf.com/reader/full/manual-mains-controller-50035400a 6/11

To add the mains controller into

an existing system please refer

to your system programming

guide for instructions on ‘adding a

product to an existing system’.

 S y s te m  p rog ra

 m m i ng g u ide

To install the entire system for

the first time, follow the astralTM 

quick start guide.

MAINS CONTROLLER INSTALLATION AND OPERATING GUIDE  10

Programming the controller into a new systemMAINS CONTROLLER INSTALLATION AND OPERATING GUIDE  11

Programming the controller into an existing system

 Q u i c k  s ta r t g u i

de

Page 7: Manual - Mains Controller (50035400_A)

8/9/2019 Manual - Mains Controller (50035400_A)

http://slidepdf.com/reader/full/manual-mains-controller-50035400a 7/11

STEP 3

CONFIGURE THE MAINS CONTROLLER

FOR GROUP OR SCENE CONTROL

The mains controller is factory-set

to control a group. To control a

scene it must first be put it into

scene control mode.

NOTE Any associations must be

deleted from the controller beforeyou will be allowed to change

control modes (see page 14 - 15).

1 Hold down the Inc/Asc button on

the controller for 8 seconds until

the indicator starts flashing yellow

and then release the button.

2 The indicator will flash 3 times to

show the new control mode:

  Green = Group control

  Red = Scene control

  If necessary repeat until the

required control mode is achieved.

STEP 4

ASSOCIATE WITH SWITCHES AND

DIMMERS TO CREATE GROUPS AND

SCENES

1 Refer to your system

programming guide for

association.

2 When you need to select the

mains controller, press theappropriate channel operation

button on the front of the mains

controller.

3 The status indicator will flash

green 3 times if the association

has been successful.

THERE ARE 4 STEPS TO ADDING

THE MAINS CONTROLLER TO AN

EXISTING SYSTEM

Step 1 Inclusion

Step 2 Replication

Step 3 Configuration

Step 4 Association

STEP 1

INCLUDE THE MAINS CONTROLLER INTO

THE SYSTEM

1 Refer to your system

programming guide for inclusion.

2 When you need to select the

mains controller to include it into

the system press any button on

the front.

3 If the mains controller is included

successfully all indicators on the

mains controller will flash green

3 times.

STEP 2

REPLICATE THE ROUTING TABLE TO ALL

CONTROLLERS

After the controller is included

into the system you must update

the routing table in all system

controllers.

1 Refer to your system

programming guide for replication.

2 Put the mains controller into

replicate receive mode, press the

Inc/Asc button for 2 seconds until

the indicator illuminates yellow.

3 The indicator will flash yellow

while the routing table is updated

and then turn green for 4 seconds

if replication has been successful.

Inc/Asc Exc/Dis

MAINS CONTROLLER INSTALLATION AND OPERATING GUIDE 

Programming the controller into an existing system  13

Page 8: Manual - Mains Controller (50035400_A)

8/9/2019 Manual - Mains Controller (50035400_A)

http://slidepdf.com/reader/full/manual-mains-controller-50035400a 8/11

DISASSOCIATION

Allows you to remove a switch

or dimmer from a group or scene

controlled from the mains controller.

1 Refer to your system manual and

put the primary controller into

disassociate mode.

2 When you need to select the

mains controller, press theappropriate operation button on

the front.

3 The status indicator will flash

green 3 times if the association

has been successfully removed.

DELETING A COMPLETE GROUP/SCENE

ON THE MAINS CONTROLLER

1 Remove the decorative fascia.

2 Hold down the Exc/Dis button

for 8 seconds until the indicator

illuminates green and then release

the button.

3 While the Exc/Dis indicator is

illuminated green, press and

release the channel operation

button on the mains controller

that controls the group or scene

to be deleted.

4 The Exc/Dis and selected channel

status indicator will flash green 10

times while the selected group or

scene is deleted.

MAINS CONTROLLER INSTALLATION AND OPERATING GUIDE 

Other programming functions

EXCLUDING THE MAINS CONTROLLER

FROM THE SYSTEM

1 Remove the decorative fascia.

2 Refer to your system

programming guide and put the

primary controller into exclude

mode.

3 Press the Exc/Dis button on the

mains controller twice within

1 second.

4 If the mains controller is excluded

successfully all indicators will

flash red 3 times.

MAINS CONTROLLER NVM RESET

WARNING Use NVM Reset with

extreme caution and only prior

to resetting all products and

completely rebuilding the network.

1 Remove the decorative fascia.

2 Hold down the Exc/Dis button

for 15 seconds until the indicator

illuminates red. Release the

button and the indicator will start

flashing red.

3 While the indicator is flashing red

press Exc/Dis for 2 seconds until

the indicator turns green and then

release the button.

4 All indicators will flash red 10

times while the mains controller

is reset and factory settings are

restored.

 

15

Inc/Asc

Inc/Asc

Inc/Asc

Inc/Asc

Page 9: Manual - Mains Controller (50035400_A)

8/9/2019 Manual - Mains Controller (50035400_A)

http://slidepdf.com/reader/full/manual-mains-controller-50035400a 9/11

FASCIA DOES NOT FIT THE CONTROLLER

• Incorrect fascia being fitted. 

You can only fit a 1 gang dimmer

fascia to a 1 gang mains controller

module and a 2 gang fascia to

a 2 gang module. You cannot fit

switch fascias to mains controller

modules.

CONTROLLER DOES NOT OPERATE

• No power to product.

Check other devices on the same

circuit are receiving power.

Check connections and wiring.

• Fuse or MCB blown.

Check and rectify fault before

replacing fuse or resetting the

MCB.

STATUS INDICATORS FLASH YELLOW

ONCE WHEN CONTROLLER IS OPERATED

• The controller has not yet been

included into a network.

CANNOT ADD THE DEVICE TO A SYSTEM

• The controller is already part

of another system. Reset the

controller first using the exclusion

process before trying again.

CANNOT ADD A SWITCH OR DIMMER TO

A GROUP/SCENE CONTROLLED BY THE

CONTROLLER

• Too many switches and dimmersalready associated. You can only

control 64 other switches or

dimmers.

CANNOT SWITCH BETWEEN GROUP AND

SCENE CONTROL

• The controller still has an

association on one or more

channels and controls another

switch or dimmer. Delete all

groups/scenes first and then

change control mode.

CANNOT ACTIVATE HOLIDAY MODE

FROM CHANNEL 1

• There is an association on

channel 1 to another switch or

dimmer. Delete all associations

on channel 1 to restore the

controllers default functionality

to channel 1.

MAINS CONTROLLER INSTALLATION AND OPERATING GUIDE  16

Troubleshooting

Suitable for flush or surface mounted

in dry interior locations only.

• Protection IP4x

• Wall box depth 35mm minimum

• Mains supply 220-240Vac / 50Hz

• Supply protection 10A MCB, type B or C

• Power consumption <1W

• Operating temperature 0°C to +45°C

 

MAINS CONTROLLER INSTALLATION AND OPERATING GUIDE  17

Specifications

RF OPERATING FREQUENCY

• Malaysia 868.1MHz

• UK/Singapore/UAE 868.4MHz

• Hong Kong 919.8MHz

Typical RF range 75m open field

The RF range quoted above is in

open field conditions. This rangewill be reduced when mounted in

a property by any walls and objects

between the transmitting and

receiving devices by an amount

dependant upon the number

of walls and their construction.

However, the effects of this will be

minimized by the mesh and routing

capabilities of the astral system.

Page 10: Manual - Mains Controller (50035400_A)

8/9/2019 Manual - Mains Controller (50035400_A)

http://slidepdf.com/reader/full/manual-mains-controller-50035400a 10/11

MAINTENANCE AND DISPOSAL

The product may be cleaned with

a dry soft lint free cloth. Do not

use water or any abrasive, solvent

based or aerosol cleaners as this

may damage, discolour or affect the

finish and safety of the product.

At the end of their useful life the

packaging, product and whereapplicable batteries, should be

disposed of via a suitable recycling

centre. Do not dispose of with your

normal household waste. Do not

burn.

COMPATIBILITY

astralTM products are tested and

certified as Z-Wave® compliant and

are designed to work with other

manufacturers Z-Wave® compliant

and interoperable products.

Z-Wave® products of other types

and applications can be added to

the system and will act as repeaters

if they support this functionality.

This enables the system to grow

and expand to other application

areas as your needs develop.

This product is supplied preset to

Low Power Configuration Mode.

PRODUCT ADVICE

If you require advice on the astralTM

system please contact the technical

service helpline on

Singapore 1800 461 6333

Malaysia 1800 88 4507

Hong Kong 2953 6379

UK and Ireland 01268 563720email [email protected]

UAE (+971) 4 807320

MAINS CONTROLLER INSTALLATION AND OPERATING GUIDE 

Additional information

GUARANTEE

MK Electric Limited undertakes to

replace or repair at its discretion

goods (excluding batteries) should

they become defective within

18 months solely as a result of

faulty materials and workmanship.

Understandably if the product has

not been installed, operated or

maintained in accordance with the

instructions, has not been used

appropriately or if any attempt has

been made to rectify, dismantle

or alter the product in any way the

guarantee will be invalidated.

The guarantee states MK Electric

Limited’s entire liability. It does not

extend to cover consequential loss

or damage or installation costs

arising from the defective product.

This guarantee does not restrict,

infringe or in any way affect the

normal statutory or other rights of

the consumer.

R&TTE DECLARATION

MK Electric Limited hereby declares

that this wirefree lighting control

product is in compliance with the

essential requirements and other

relevant provisions of the European

Radio and Telecommunications

Terminal Equipment (R&TTE)

directive, 1999/5/EC.

DESIGN OWNERSHIP

MK Electric Limited wishes to make

it clear that it owns all the original

designs of the products that it

manufactures (whether or not listed

in this leaflet) and that it will take all

necessary action in any part of the

world against any party found to be

manufacturing, distributing, selling

or otherwise dealing with any article

which infringes the Company’s

intellectual property in its own

products, or any other right of the

company.

MK is a registered trademark of

Novar ED&S

Zensys and Z-Wave is a registered

trademark of Zensys Ltd

Patents applied for and pending

Registered designs 

19

Page 11: Manual - Mains Controller (50035400_A)

8/9/2019 Manual - Mains Controller (50035400_A)

http://slidepdf.com/reader/full/manual-mains-controller-50035400a 11/11

50035400.001 Ed.A

MK Electric Ltd 

The Arnold Centre, Paycocke Road, Basildon,

Essex SS14 3EA United Kingdom

MK Electric (Middle East)

Honeywell ME, FZE, P.O. Box 18530, Jebel All,

Dubai U.A.E.

MK Electric (Singapore) Pte Ltd

8 Pandan Crescent, UE Tech Park, #01-06

(LL4), Singapore 128464

MK Electric (Malaysia) Sdn Bhd

(Co. No. 39068-A). Komplek Perusahaan LTAT,

Jalan Pengapit 15/19, 40000 Shah Alam,

Selangor Darul Ehsan, Malaysia

MK Electric (China) Ltd

25/F, Honeywell Tower, Olympia Plaza,

255 King’s Road, North Point, Hong Kong

Telephone +44 (0)1268 563000

Fax +44 (0)1268 563404

Email [email protected]

Telephone (+971) 4 807 3200

Fax (+971) 4 881 5733

Telephone (+65) 6461 6333

Fax (+65) 6461 6336 / 6338

Telephone (+603) 5519 4507

Fax (+603) 5510 8867

Telephone (+852) 2331 9133

  (+852) 2834 1988

Fax (+852) 2151 9465

www.mkelectric.co.uk

Novar ED&S Ltd (A Honeywell Company)

Arlington Business Park, Bracknell, Berkshire RG12 1EB UK

© Novar ED&S Limited 2008 All rights reserved