manual swd8 (ing)

2
Rope sensor for elevators load control Serie: SW-D Ø 8...16 mm Manual OF Installation Dinacell Electrónica, s.l. C/ Andrés Obispo, 27 - 28043 Madrid - Tel. 913 001 435 - Fax: 913 001 645 E-mail: [email protected] - http://www.dinacell.com SENSOR MESH EXC.+ +IN EXC.- -IN AL-S AL-C AUX. Power supply Exit of relay Overload Complete Cable screen Black White Green Red SERIES VK ~ 4 AL-C 1 3 2 6 5 AL-S 220 MENU VK-2T SW - D Load Cells 1 2 Step 5. Connection of the sensor (SW-D) to unit control (VK) Connection of the sensor (SW-D) in 4 ropes elevator. In this case as what shown in this figu- re you will need 2 sets of sensor SW-D. Each sensor is composed of 2 active cells. Once the sensor is already connected to the unit control VK, you could start to calibrate the unit (Please look at the manual instruction of the unit VK for the calibration process). Unite all the wire with the same color and connect it to the unit control VK.

Upload: dinacell-electronica-sl

Post on 08-Feb-2016

227 views

Category:

Documents


9 download

DESCRIPTION

Manual del equipo SWD8 en formato pdf (idioma:inglés)

TRANSCRIPT

Page 1: Manual SWD8 (ing)

Rope sensor forelevators load controlSerie: SW-D

Ø 8...16 mm

Manual OF InstallationDinacell EElectrónica, ss.l.C/ Andrés Obispo, 27 - 28043 Madrid - Tel. 913 001 435 - Fax: 913 001 645E-mail: [email protected] - http://www.dinacell.com

SENSOR

MES

H

EXC

.+

+IN

EXC

.-

-IN

AL-SAL-C

AUX.

Power supplyExit of relay

OverloadComplete

Cable screen

Black

WhiteGreen

Red

SERIES VK

~4AL-C

1 3

2

6

5

AL-S220

MENU

VK-2T

SW - DLoad Cells

1 2

Step 5. Connection of the sensor (SW-D) to unit control (VK)

Connection of the sensor (SW-D) in 4 ropes elevator.In this case as what shown in this figu-re you will need 2 sets of sensor SW-D.Each sensor is composed of 2 activecells.

Once the sensor is already connected to the unit control VK, you could start to calibratethe unit (Please look at the manual instruction of the unit VK for the calibration process).

Unite all the wirewith the same colorand connect it to theunit control VK.

Page 2: Manual SWD8 (ing)

Manual of Installation Serie SW-D

Models Diameter of the cable Range of load(standard)

SW-D8 Ø 8, 9, 10 600 kg/cableSW-D11 Ø 11, 12, 13 800 kg/cableSW-D14 Ø 14, 15 16 1.600 kg/cable

1. INTRODUCTION

A load weighing device model SW-D8/16, composed of 2 active load cell was deve-loped to measure the weight on elevators and freight elevators.

In this new sensor whose placement is carried out individually in each cable, you willfind more advantages on the installation.

Advantages of the sensor SW-D- Installation and maintenance at low cost.- Fast and easy to install( Installation takes only a few minutes,no need to waste

time to screws).- Flexibility to place in an convenient position.

2. MODELS OF THE SERIE SW-D

Contents:a) Sensor SW-Db) 3 pins of support (2 fix pins & 1 loose pin)c) Installation tools

3. INSTALLATION OF THE SENSOR SW-D

In each cable must place a sensor.

The sensor has 2 fixed pins on it and once it is already placeon the cable, the last pin must be introduce.

Step 1

You could place the sensor on the tools or putdirectly the sensor on the cable and hold it by thetool.

Step 2

Now fit the sensor on the cable and start to bend.

Step 3

Then once the hole of the sensor is already atsight, introduce the third pin on the hole.

Step 4

Finally upon introducing the last pin, the sensor is now readyto function.

Same procedure must be repeated to install the other sensor.

Note: The Sensor could placed in the position that youconsiders more suitable. You have to avoid the crash ofone against the other.