masterplex qt: luminex multiplex quantitative analysis software

13
© Hitachi Software Engineering America, Ltd. 2010. All rights reserve Presenters: Robert Lynde Deputy Director Sales Operations & Strategic Alliances Manager Allen Liu Supervisor Technical Support & Project Management Webinar: Improving your results with MasterPlex QT July 29, 2010 presentation accompanies the free webinar recording ://www1.gotomeeting.com/register/351125992

Upload: allen-liu

Post on 19-Nov-2014

161 views

Category:

Documents


1 download

DESCRIPTION

MasterPlex QT is a multiplex curve-fitting analysis software for the Luminex xMAP & Bio-Plex platforms.This presentation accompanies the following free webinar: https://www1.gotomeeting.com/register/351125992The webinar begins with a close-up look at the 4 Parameter Logistic (4PL) and 5 Parameter Logistic (5PL) nonlinear regression models. Then it goes into how Luminex xMAP/Bio-Plex users can improve their results with MasterPlex QT and covers some of the following topics:- Heteroscedasticity & Weighting- BONUS: What’s New in MasterPlex QT 2010- Ensuring the quality of your data with the Quality Control Manager- How to use time-saving features such as templates & Best FitMasterPlex QT product page: http://www.miraibio.com/qt

TRANSCRIPT

Page 1: MasterPlex QT: Luminex Multiplex Quantitative Analysis Software

© Hitachi Software Engineering America, Ltd. 2010. All rights reserved.

Presenters: Robert LyndeDeputy DirectorSales Operations & Strategic Alliances Manager

Allen LiuSupervisorTechnical Support & Project Management

Webinar: Improving your results with MasterPlex QT

July 29, 2010

This presentation accompanies the free webinar recording at:https://www1.gotomeeting.com/register/351125992

Page 2: MasterPlex QT: Luminex Multiplex Quantitative Analysis Software

© Hitachi Software Engineering America, Ltd. 2010. All rights reserved.

1) A close up look at the 4-PL and 5-PL model equations2) Heteroscedasticity & Weighting3) BONUS: What’s New in MasterPlex QT 20104) Ensuring the quality of your data with the Quality Control

Manager5) How to use time-saving features such as templates & Best Fit

Topics

Page 3: MasterPlex QT: Luminex Multiplex Quantitative Analysis Software

© Hitachi America, Ltd. 2010. All rights reserved.

4 Parameter Logistic (4PL)

• F(x) = ((A-D)/(1+((x/C)^B))) + D

• Nonlinear regression

• Monotonic– e.g. For every MFI, there is only one

concentration

• Symmetrical around the midpoint or inflection point

3

Page 4: MasterPlex QT: Luminex Multiplex Quantitative Analysis Software

© Hitachi America, Ltd. 2010. All rights reserved. 4

4 Parameter Logistic (4PL)

A = minimum asymptote

D = maximum asymptote

C = inflection pointB = slope factor/steepness of curve

< low standard OR lowest extrapolated value

> high standard OR highest extrapolated value

Page 5: MasterPlex QT: Luminex Multiplex Quantitative Analysis Software

© Hitachi America, Ltd. 2010. All rights reserved.

Caution on Extrapolation

5

tiny change in MFI = HUGE change in concentration

Page 6: MasterPlex QT: Luminex Multiplex Quantitative Analysis Software

© Hitachi America, Ltd. 2010. All rights reserved.

5 Parameter Logistic (5PL)

• F(x) = A + (D/(1+(X/C)^B)^E)

• Nonlinear regression

• Monotonic

• Key difference = asymmetry

• E = asymmetry factor

• E = 1 = 4PL model equation

6

Page 7: MasterPlex QT: Luminex Multiplex Quantitative Analysis Software

© Hitachi America, Ltd. 2010. All rights reserved.

5 Parameter Logistic (5PL)

Page 8: MasterPlex QT: Luminex Multiplex Quantitative Analysis Software

© Hitachi America, Ltd. 2010. All rights reserved.

Assumptions of the 4PL & 5PL

• 2 assumptions about how the data are scattered around the curve…1. The scatter follows a Gaussian or “normal”

distribution

2. The standard deviation of the scatter (of the response values or MFI) is the same for all values of x (or concentrations in our case)

8

Page 9: MasterPlex QT: Luminex Multiplex Quantitative Analysis Software

© Hitachi America, Ltd. 2010. All rights reserved.

Heteroscedasticity

9

Page 10: MasterPlex QT: Luminex Multiplex Quantitative Analysis Software

© Hitachi America, Ltd. 2010. All rights reserved.

Weighting

• 1/Y^2 (Relative weighting) – Most commonly used

• 1/Y – Most effective when the scatter follows a Poisson distribution

• Mainly affects points on the lower portion of the curve

• Test by doing before/after on the % Recovery

10

Page 11: MasterPlex QT: Luminex Multiplex Quantitative Analysis Software

© Hitachi Software Engineering America, Ltd. 2010. All rights reserved.

• Expanded Platform Support• Meso Scale Discovery (MSD) platform compatibility

• Improved Data Integrity• Built-in Quality Control Manager• Added new Upper Limit of Detection calculation for QC

Manager• Further Time-saving

• Auto calculation for plate templates• Dose Response Analysis

• EC or IC50 calculation • EC or IC(anything) calculation

• Enhanced Reporting• Merge group wells in the Data Table• Customizable standard curve chart titles & x/y-axes

What’s new for MasterPlex QT 2010?

Page 12: MasterPlex QT: Luminex Multiplex Quantitative Analysis Software

© Hitachi Software Engineering America, Ltd. 2010. All rights reserved.

• Free 14-Day Trial: http://www.MiraiBio.com/QT• Support: [email protected]• Sales: [email protected]• MiraiBio Support Menu

• Community• Knowledge Base• Blog

• Webinars: http://www.MiraiBio.com/Webinars

Resources

Page 13: MasterPlex QT: Luminex Multiplex Quantitative Analysis Software

© Hitachi America, Ltd. 2010. All rights reserved. 13