measurements using a gtem cell above 1ghz dr tian hong loh

30
Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Upload: hilda-lyons

Post on 17-Jan-2016

216 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Measurements using a GTEM cell above 1GHz

Dr Tian Hong LOH

Page 2: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Overview of the Presentation

• Introduction to GTEM cell

• Reason for GTEM measurement above 1GHz

• Equipment under test (EUT)

• Experimental Setup

• Experimental Results

Page 3: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Overview of the Presentation

• Introduction to GTEM cell

• Reason for GTEM measurement above 1GHz

• Equipment under test (EUT)

• Experimental Setup

• Experimental Results

Page 4: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Introduction: What’s GTEM?

• GTEM cell – Giga-Hertz Transverse Electromagnetic cell.• Tapered Coaxial Transmission Line with 50 termination

at both ends.

Page 5: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Introduction: What’s GTEM?

• Designed for use as EMC radiated emission and radiated immunity test facility without impact of the ambient electromagnetic environment.

Page 6: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Introduction: What’s GTEM?

• At the input, a normal 50 coaxial line is physically transformed to a rectangular cross section.

• The cross sectional dimensions are a ratio of 3:2 horizontal to vertical cross sectional dimensions.

a

b

b/a = 3/2

Page 7: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Introduction: What’s GTEM?

• The centre conductor – septum, is a flat and wide conductor that will produce a uniform electrical field distribution underneath it which form a test volume for testing the EUT.

Page 8: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Overview of the Presentation

• Introduction to GTEM cell

• Reason for GTEM measurement above 1GHz

• Equipment under test (EUT)

• Experimental Setup

• Experimental Results

Page 9: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Reason for GTEM measurement above 1GHz

• The use of GTEM cell above 1GHz is still novel to product manufacturers.

• Increasing clock speed of computer processors.

• The need to measure the wave structure and to understand potential limitations in the use of the cell at higher frequencies.

Page 10: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Overview of the Presentation

• Introduction to GTEM cell

• Reason for GTEM measurement above 1GHz

• Equipment under test (EUT)

• Experimental Setup

• Experimental Results

Page 11: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Equipment under test (EUT)

• Dummy device that is commissioned resembling typical products.

• Consists of monocone antenna as radiating source mounted on the inside of a metal box.

Page 12: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Equipment under test (EUT)

• Power by a battery operated York EMC Services CGE01 comb generator with 100MHz harmonic spacing.

• Fundamental signal of 100MHz.• Measurable E-field from EUT up to 15GHz.

Page 13: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Equipment under test (EUT)

• Small EUT (SEUT): [ (L:W:H) = 23cm 20cm 11cm ]

Side 5

Side 2Side 1

Side 5

Side 3 Side 2

Page 14: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Equipment under test (EUT)

• Large EUT with complicated slots (LEUTC):

[ (L:W:H) = 12.5cm 48.5cm 48.5cm ]

Side 1

Side 2

Side 3

Page 15: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Overview of the Presentation

• Introduction to GTEM cell

• Reason for GTEM measurement above 1GHz

• Equipment under test (EUT)

• Experimental Setup

• Experimental Results

Page 16: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Experimental Setup

• Instrumentation used:

1. Spectrum Analyser (PSA)

2. Microwave Amplifier

3. Cables

4. Computer System

5. GTEM cell

6. Foam Table

7. EUT

12

3

4

5

Page 17: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Experimental Setup

Ver

tica

l P

olar

isat

ion

75

• Instrumentation used:

1. Spectrum Analyser (PSA)

2. Microwave Amplifier

3. Cables

4. Computer System

5. GTEM cell

6. Foam Table

7. EUT 6

Page 18: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Experimental Setup

• SEUT:

1750mm1620mm

450mm535mm590mm

645mm

1

Page 19: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Experimental Setup

• SEUT:

1750mm1620mm

450mm535mm590mm

645mm

1120mm

3mm483mm

538mm

12

Page 20: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Experimental Setup

• SEUT:

1750mm1620mm

450mm535mm590mm

645mm

1120mm

3mm483mm

538mm

820mm

255mm

60mm370mm

425mm

12

3

Page 21: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Experimental Setup

• LEUTC:

1750mm

1620mm

450mm

85mm

485mm

535mm

777.5mm

125mm

Page 22: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Overview of the Presentation

• Introduction to GTEM cell

• Reason for GTEM measurement above 1GHz

• Equipment under test (EUT)

• Experimental Setup

• Experimental Results

Page 23: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Experimental Results

• SEUT: Sensitivity --- Transverse displacement

0 1 2 3 4 5 6 7 8

x 109

-100

-90

-80

-70

-60

-50

-40

-30

Frequency (Hz)

Pe

ak

sea

rch

on

ha

rmo

nic

s (d

Bm

)

Emission Sensitivity Measurement - Transverse displacement (Side1 face apex)

centreL.H.S. 50mmL.H.S. 100mmR.H.S. 50mmR.H.S. 100mm

0 1 2 3 4 5 6 7 8

x 109

0

2

4

6

8

10

12

14

Frequency (Hz)

Co

mp

ari

son

(d

B)

Emission Sensitivity Measurement - Transverse displacement (Side1 face apex)

abs[ (L.H.S. 50mm) - (centre) ]abs[ (L.H.S. 100mm) - (centre) ]abs[ (R.H.S. 50mm) - (centre) ]abs[ (R.H.S. 100mm) - (centre) ]

Page 24: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Experimental Results

• SEUT: Sensitivity --- Vertical displacement

0 1 2 3 4 5 6 7 8

x 109

-100

-90

-80

-70

-60

-50

-40

-30

Frequency (Hz)

Pe

ak

sea

rch

on

ha

rmo

nic

s (d

Bm

)

Emission Sensitivity Measurement - Vertical displacement (Side1 face apex)

0 1 2 3 4 5 6 7 8

x 109

0

5

10

15

20

Frequency (Hz)

Co

mp

ari

son

(d

B)

Emission Sensitivity Measurement - Vertical displacement (Side1 face apex)

620mm720mm820mm

abs[ (720mm) - (620mm) ]abs[ (820mm) - (620mm) ]

Page 25: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Experimental Results

• SEUT: E-field comparison between GTEM & FAR

1 2 3 4 5 6 7 8

x 109

65

70

75

80

85

90

95

Frequency (Hz)

E f

ield

Str

en

gth

[d

B(u

V/m

)]

Comparison between Emission measurement of SEUT in GTEM and FAR

GTEM 2m E-field at 1620mm septem heightGTEM 2m E-field at 1120mm septem heightGTEM 2m E-field at 820mm septem heightFAR 2m E-field, Ant. VP, 2m away from SEUT

Page 26: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Experimental Results

• LEUTC: E-field comparison between GTEM & FAR

2 4 6 8 10 12 14

x 109

40

45

50

55

60

65

70

75

80

85

90

95

Frequency (Hz)

E f

ield

Str

en

gth

[d

B(u

V/m

)]Comparison between Emission measurement of Vertically Polarised LEUTC in GTEM and FAR

GTEM, NORMAL detectorFAR, PEAK detector, Antenna Vertically Polarised, 3m away from LEUTC for all antenna heights

Page 27: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Modified Experimental Setup

• LEUTC:

1750mm

1620mm

450mm85mm

485mm

535mm

777.5mm

125mm

Stepper Motor

Page 28: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Experimental results

• LEUTC: E-field comparison between GTEM & FAR

2 4 6 8 10 12 14

x 109

40

45

50

55

60

65

70

75

80

85

90

95

Frequency (Hz)

E f

ield

Str

en

gth

[d

B(u

V/m

)]Comparison between Emission measurement of Vertically Polarised LEUTC in GTEM and FAR

GTEM, MAX E-field in azimuth cutGTEM, E-field obtained from three position RSS algorithmFAR, MAX E-field, VP Ant., 3m away from LEUT for all antenna heights

Page 29: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Experimental results: Radiation Pattern

• Radiation pattern of LEUTC in GTEM:

Page 30: Measurements using a GTEM cell above 1GHz Dr Tian Hong LOH

Thank you for your attention.

Any Questions?