measuring instruments directive 2010

17
Measuring Instruments Directive Measuring Instruments Directive for manufacturers and end-users selling and using instruments mentioned for trade NMi Certin B.V., Bert Jan Siebesma, Account manager

Upload: nmi

Post on 21-Jun-2015

1.089 views

Category:

Business


1 download

TRANSCRIPT

Page 1: Measuring instruments directive 2010

Measuring Instruments DirectiveMeasuring Instruments Directivefor

manufacturers and end-users sellinggand using instruments mentioned for trade

NMi Certin B.V., Bert Jan Siebesma, Account manager

Page 2: Measuring instruments directive 2010

Contents of the presentationContents of the presentation

– Verification versus calibration

– Scope of the MID

Declare confirmation– Declare confirmation

– Gas meters & Volume Conversion Devices

– Liquid installations

– QuestionsQuestions

7-7-2010

2

Page 3: Measuring instruments directive 2010

Verification versus calibration

– Custody transfer is subjected to the Metrology lawCustody transfer is subjected to the Metrology law

– Metrology law has restrictions of interference

– Verifications = law

– Calibrations = voluntary

7-7-2010

3

Page 4: Measuring instruments directive 2010

27 EU Members 1. Austria27 EU Members 1. Austria2. Belgium3. Bulgaria4. Cyprus5. Czech Republic5. Czech Republic6. Denmark7. Estonia8. Finland9. France9. France10. Germany11. Greece12. Hungary13. Ireland13. Ireland14. Italy15. Latvia16. Lithuania17. Luxembourgu e bou g18. Malta19. Netherlands20. Poland21. Portugalg22. Romania23. Slovakia24. Slovenia25. Spain

7-7-2010

4

p26. Sweden27. United Kingdom

Page 5: Measuring instruments directive 2010

Single European marketg p

Only 1 approval = MID for:Only 1 approval MID for:

– 27 countries + 4 EFTA countries: Iceland, Norway, Switzerland, Liechtenstein

– > 450.000.000 people

– > 4.000.000 km2

MID is in force since 30st of October– MID is in force since 30st of October 2006.

7-7-2010

5

Page 6: Measuring instruments directive 2010

Scope of MIDp

7-7-2010

6

Page 7: Measuring instruments directive 2010

Scope of MIDp

Placing on the market (1st stage)g g

Putting into use (2nd stage)

f l dNot for instruments already in use

New Approach Directive and is: “technology independent”

Part of the “CE-system”

Intention of Brussels: remove barriers to tradeIntention of Brussels: remove barriers to trade

National differences domestic / light / heavy industry, iwater in-out etc.

Note: re-verification and inspection are still a national issue!

7-7-2010

7

Page 8: Measuring instruments directive 2010

MID AnnexesMID Annexes

Water meters MI-001 B+F, B+D, H1, ,

Gas meters & Volume Conversion Devices

MI-002 B+F, B+D, H1

El t i it t MI 003 B F B D H1Electricity meters MI-003 B+F, B+D, H1

Heat meters MI-004 B+F, B+D, H1

Liquid installations MI-005 B+F B+D H1 GLiquid installations MI 005 B+F, B+D, H1, G

Automaticweighing

MI-006 B+F, B+D, H1, G(B+E, D1,F1)

Taximeters MI-007 B+F, B+D, H1

Material measures MI-008 A1, F1, D1, E1, B+E, B+D,H

Dimensional meas rement MI 009 B F B D H1 GDimensional measurement MI-009 B+F, B+D, H1, G(F1, D1, E1, B+E ,H)

Exhaust gas analysers MI-010 B+F, B+D, H1

7-7-2010

8

g y

Page 9: Measuring instruments directive 2010

MID Modules

B

C D E F H

Type examination by Notified Body (NB)

CDoC to

TYPE

DDoC to

TYPE

EDoC to

TYPE

FDoC to

TYPE

GDoC

HDoC

ADoC

QAInternal

ProductionC l

QAProduction

Process

QAProduct

Inspection & i

ProductVerification

by NB

Unit Verification

by NB

FullQA

Control

InternalProduction

controlControl

(C1) (D1)

& testing

(E1) (F1) (H1)(A1)

7-7-2010

9

Page 10: Measuring instruments directive 2010

Declare conformationOn which base can one declare conformity?

1. Harmonized Standards, published in the Official Journey (OJ)

2. Use of Normative Documents (OIML)Gas OIML R137 1 (GC R140)Gas = OIML R137-1 (GC = R140)Liquid = OIML R117-1

3. Opinion of Notified Body via for example:* GROWTH (MID-procedures)* WELMEC and so on.

Note!: Software is an issue in MID see Welmec Guide 7 2

7-7-2010

10

Note!: Software is an issue in MID, see Welmec Guide 7.2

Page 11: Measuring instruments directive 2010

Gas “meters” and Volume Conversion D iDevices

- MID not applicable outside territorial waters

- MID applicable in Netherlands if < 170.000 Nm3/y but differs from country to countryy y

- EMC / Electrical requirements

- Importance OIML R137-1

- Software importance

- Responsibility move from manufacturer to end-users

7-7-2010

11

Page 12: Measuring instruments directive 2010

Liquid “installations”Liquid installations

- MID not applicable outside territorial waters

- MID applicable to liquid systems!

EMC / El t i l i t- EMC / Electrical requirements

- Importance OIML R117-1

- Software importance

Responsibility move from manufacturer to end users- Responsibility move from manufacturer to end-users

7-7-2010

12

Page 13: Measuring instruments directive 2010

How to comply to MIDp y

Manufacturer is responsible for:Manufacturer is responsible for:

– Conformity with MID

– Affixing CE mark (Conformité Européene)

Affi i l ki– Affixing metrology markings

– Declaration of ConformityDeclaration of Conformity

M 10M 10 0122

7-7-2010

13CE mark Metrology mark Notified body no.

Page 14: Measuring instruments directive 2010

Transition periodp

– MID has no influence on already placed instruments

New approvals or revisions under “old” regime not– New approvals or revisions under “old” regime not possible when MID is in force

– After introduction MID, “old” approvals valid for another 10 years

– Mix / match and equilty principle in Netherlands for installed instruments

7-7-2010

14

Page 15: Measuring instruments directive 2010

Putting into usePutting into use…Gasmeters & EVCD = Module F or D for1st verifications1st verifications

Liquidinstallations = Module F or D for1st ifi ti1st verifications

Certified verification officer = repair, maintenance, ifi ti i N th l d lre-verification in Netherlands only

Producer D for parts

Pre-calibrations liquid meters as part of F / D forliquid installations. How to handle?

7-7-2010

15

Page 16: Measuring instruments directive 2010

Curious?For information please contact :

NMi Certin B.V.Hugo de Grootplein 13314 EG DordrechtThe Netherlands

T +31 78 633 2308T +31 78 633 2308F +31 78 633 2309E [email protected] www NMi nlI www.NMi.nl

Account Manager Oil & Gas: Bert Jan Siebesma Inside Sales engineer: Janneke de KreijInside Sales engineer: Janneke de Kreij Product Manager Oil & Gas: Wim VolmerSales Director: Paul van Enckevort

Page 17: Measuring instruments directive 2010