measuring instruments directive 2010
TRANSCRIPT
Measuring Instruments DirectiveMeasuring Instruments Directivefor
manufacturers and end-users sellinggand using instruments mentioned for trade
NMi Certin B.V., Bert Jan Siebesma, Account manager
Contents of the presentationContents of the presentation
– Verification versus calibration
– Scope of the MID
Declare confirmation– Declare confirmation
– Gas meters & Volume Conversion Devices
– Liquid installations
– QuestionsQuestions
7-7-2010
2
Verification versus calibration
– Custody transfer is subjected to the Metrology lawCustody transfer is subjected to the Metrology law
– Metrology law has restrictions of interference
– Verifications = law
– Calibrations = voluntary
7-7-2010
3
27 EU Members 1. Austria27 EU Members 1. Austria2. Belgium3. Bulgaria4. Cyprus5. Czech Republic5. Czech Republic6. Denmark7. Estonia8. Finland9. France9. France10. Germany11. Greece12. Hungary13. Ireland13. Ireland14. Italy15. Latvia16. Lithuania17. Luxembourgu e bou g18. Malta19. Netherlands20. Poland21. Portugalg22. Romania23. Slovakia24. Slovenia25. Spain
7-7-2010
4
p26. Sweden27. United Kingdom
Single European marketg p
Only 1 approval = MID for:Only 1 approval MID for:
– 27 countries + 4 EFTA countries: Iceland, Norway, Switzerland, Liechtenstein
– > 450.000.000 people
– > 4.000.000 km2
MID is in force since 30st of October– MID is in force since 30st of October 2006.
7-7-2010
5
Scope of MIDp
7-7-2010
6
Scope of MIDp
Placing on the market (1st stage)g g
Putting into use (2nd stage)
f l dNot for instruments already in use
New Approach Directive and is: “technology independent”
Part of the “CE-system”
Intention of Brussels: remove barriers to tradeIntention of Brussels: remove barriers to trade
National differences domestic / light / heavy industry, iwater in-out etc.
Note: re-verification and inspection are still a national issue!
7-7-2010
7
MID AnnexesMID Annexes
Water meters MI-001 B+F, B+D, H1, ,
Gas meters & Volume Conversion Devices
MI-002 B+F, B+D, H1
El t i it t MI 003 B F B D H1Electricity meters MI-003 B+F, B+D, H1
Heat meters MI-004 B+F, B+D, H1
Liquid installations MI-005 B+F B+D H1 GLiquid installations MI 005 B+F, B+D, H1, G
Automaticweighing
MI-006 B+F, B+D, H1, G(B+E, D1,F1)
Taximeters MI-007 B+F, B+D, H1
Material measures MI-008 A1, F1, D1, E1, B+E, B+D,H
Dimensional meas rement MI 009 B F B D H1 GDimensional measurement MI-009 B+F, B+D, H1, G(F1, D1, E1, B+E ,H)
Exhaust gas analysers MI-010 B+F, B+D, H1
7-7-2010
8
g y
MID Modules
B
C D E F H
Type examination by Notified Body (NB)
CDoC to
TYPE
DDoC to
TYPE
EDoC to
TYPE
FDoC to
TYPE
GDoC
HDoC
ADoC
QAInternal
ProductionC l
QAProduction
Process
QAProduct
Inspection & i
ProductVerification
by NB
Unit Verification
by NB
FullQA
Control
InternalProduction
controlControl
(C1) (D1)
& testing
(E1) (F1) (H1)(A1)
7-7-2010
9
Declare conformationOn which base can one declare conformity?
1. Harmonized Standards, published in the Official Journey (OJ)
2. Use of Normative Documents (OIML)Gas OIML R137 1 (GC R140)Gas = OIML R137-1 (GC = R140)Liquid = OIML R117-1
3. Opinion of Notified Body via for example:* GROWTH (MID-procedures)* WELMEC and so on.
Note!: Software is an issue in MID see Welmec Guide 7 2
7-7-2010
10
Note!: Software is an issue in MID, see Welmec Guide 7.2
Gas “meters” and Volume Conversion D iDevices
- MID not applicable outside territorial waters
- MID applicable in Netherlands if < 170.000 Nm3/y but differs from country to countryy y
- EMC / Electrical requirements
- Importance OIML R137-1
- Software importance
- Responsibility move from manufacturer to end-users
7-7-2010
11
Liquid “installations”Liquid installations
- MID not applicable outside territorial waters
- MID applicable to liquid systems!
EMC / El t i l i t- EMC / Electrical requirements
- Importance OIML R117-1
- Software importance
Responsibility move from manufacturer to end users- Responsibility move from manufacturer to end-users
7-7-2010
12
How to comply to MIDp y
Manufacturer is responsible for:Manufacturer is responsible for:
– Conformity with MID
– Affixing CE mark (Conformité Européene)
Affi i l ki– Affixing metrology markings
– Declaration of ConformityDeclaration of Conformity
M 10M 10 0122
7-7-2010
13CE mark Metrology mark Notified body no.
Transition periodp
– MID has no influence on already placed instruments
New approvals or revisions under “old” regime not– New approvals or revisions under “old” regime not possible when MID is in force
– After introduction MID, “old” approvals valid for another 10 years
– Mix / match and equilty principle in Netherlands for installed instruments
7-7-2010
14
Putting into usePutting into use…Gasmeters & EVCD = Module F or D for1st verifications1st verifications
Liquidinstallations = Module F or D for1st ifi ti1st verifications
Certified verification officer = repair, maintenance, ifi ti i N th l d lre-verification in Netherlands only
Producer D for parts
Pre-calibrations liquid meters as part of F / D forliquid installations. How to handle?
7-7-2010
15
Curious?For information please contact :
NMi Certin B.V.Hugo de Grootplein 13314 EG DordrechtThe Netherlands
T +31 78 633 2308T +31 78 633 2308F +31 78 633 2309E [email protected] www NMi nlI www.NMi.nl
Account Manager Oil & Gas: Bert Jan Siebesma Inside Sales engineer: Janneke de KreijInside Sales engineer: Janneke de Kreij Product Manager Oil & Gas: Wim VolmerSales Director: Paul van Enckevort