mediva t5 - tlv€¦ · mediva is designed to be fed: - from behind (a), via a cut-out in the bed...
TRANSCRIPT
Normal care / Horizontal Bed head units
MEDIVA LEDT5Dynamic Lighting
2 www.tlv-healthcare.com
STRENGTHS
MEDIVA’s electrical devices are ideally positioned, with easy access for patients and care staff.
The bed head unit has smooth surfaces, making it easy to clean.
Design & Ergonomics
MEDIVA’s separate compartment for medical gas provide quick and easy access for installation and maintenance.
The bed head unit can be installed quickly in just three steps, saving time and manpower.
Easy maintenance
Gas casing are available in seven colours, to match with the decor of normal care rooms.
Personalisation+ + +
3 www.tlv-healthcare.com
TECHNICAL FEATURES
Cross-section
1 General and Night light compartment
2 Reading lighting compartment
3 Low voltage compartment
4 Extra low voltage compartment
5 Medical gas compartment
183 mm
164 mm
1
5
34
2
Front view
Clipped covers
Low and extra low voltage equipment
Clipped general lighting diffuser
Medical gas equipment
ABS/PC end cap
Reading lighting
Colours
Seven panel colours, to match the MEDIVA with the decor of your normal care rooms.
WHITERAL 9016
GREYRAL 9006
GREYRAL 7040
ORANGERAL 2003
BLUERAL DESIGN
260 80 15
PLUMRAL DESIGN
330 30 35
PINKRAL DESIGN
010 80 20
GREENRAL DESIGN
110 70 77
Aluminum profile
End caps
Gas casing
4 www.tlv-healthcare.com
FUNCTIONALITY
The MEDIVA bed head unit is entirely custom made, and provides comfortable, soothing indirect lighting for patients and care teams.
InstallationThe MEDIVA is quick and easy to install thanks to its screw-mounting system via the back of the bed head unit.
Medical gas casingThe ABS / PC medical gas casing, available with flap (A) or without flap (B), allow any gas outlet to be installed (e.g.: AFNOR, DIN, BS, etc.).
A B
Power supplyMEDIVA is designed to be fed: - From behind (A), via a cut-out in the bed head unit - From the ceiling, by a riser (B) - From the side, through an extra duct (C)
Electrical equipment integrationThe waterjet cutting of the MEDIVA’s cover enables exact and customized cutting. It can integrate all forms of outlets. Flush mounting of electrical equipment enables easier cleaning and disinfection of the product.
C
A
B
Wall
5 www.tlv-healthcare.com
CONTROLLED LIGHTING
Efficient lightingThe reflectors provide high output and focus the light.
Comfortable lightingReading lighting is provided with an anti glare effect diffuser.
Controlled and directed lightingGeneral lighting includes a diffuser with prism which directs the luminous flux toward the centre of the room.
The optics of the MEDIVA allow optimum control of the lighting, favouring the well-being of care teams and patients.
General lighting
Reading lighting
Caring lighting
Caring lighting combines direct (reading) lighting with indirect (general) lighting.
- Opal polycarbonate diffuser (LED) or with opal grooves (T5) with anti-UV treatment
- MIRO SILVER® (T5) and MIRO 20 SILVER® (LED) aluminium reflector
- Clear polycarbonate diffuser (T5) or opal (LED) with anti-UV treatment
- MIRO SILVER® (T5) and MIRO 20 SILVER® (LED) aluminium reflector
6 www.tlv-healthcare.com
EFFICIENT LIGHTING
Lighting study
• Standard room
• Dimensions of the room: 3 m x 3 m, ceiling clearance 2.5 m
• Reflection coefficients: ceiling 7, walls 5, and floor 3
• Coefficient of depreciation 0.831
3
22
* Available in 3000 K or 4000 K (Night light only in 3000 K)
Lighting power
Lighting Power Types of source / Endsocket Luminous Flux Consumption System
Efficiency Gear(s) / Driver(s)
General lighting
2 x 54 W T5 / G5 9000 lm 118 W 76 lm/W EVG / EVG Dimm / EVG Dimm Dali
1 x 80 W T5 / G5 6150 lm 86 W 71,5 lm/W EVG / EVG Dimm / EVG Dimm Dali
1 x 54 W T5 / G5 4450 lm 61 W 73 lm/W EVG / EVG Dimm / EVG Dimm Dali
36,7 W (4 Ft) LED* 5674 lm 42,1 W 135 lm/W Fixed / 1-10 V / DALI
45,5 W (5 Ft) LED* 7093 lm 52,2 W 136 lm/W Fixed / 1-10 V / DALI
Reading lighting
1 x 24 W T5 / G5 1750 lm 27 W 65 lm/W EVG / EVG Dimm / EVG Dimm Dali
1 x 36 W LC (lampe Fluo compacte) / 2G11 2900 lm 38 W 76 lm/W EVG / EVG Dimm /
EVG Dimm Dali
10,5 W (2 Ft) LED* 1811 lm 13,8 W 131 lm/W Fixed / 1-10 V / DALI
Night light1 x 7 W LC (lampe Fluo
compacte) / 2G11 400 lm 9 W 44,5 lm/W EVG
1 x 3,2 W LED* 350 lm 5,2 W 67,5 lm/W Fixed
General lightingVirtual general lighting plane of a surface equal to the one of the room, located 0.85 m above the floor (3 m x 3 m for a single room).
Reading lightingVirtual reading plane 0.3 m x 0.3 m inclined at 75° located 1.1 m from the floor and 1 m from the wall where the light fitting is mounted.
Caring lighting Virtual examination plane 2 m x 0.9 m located 0.85 m from the floor, centred in width and 0.1 m from the wall.
FLUO T5 1 x 54 W
MEDIVA T5
13.12.2016
TRATO - TLV
22 rue Molière BP36959057 Roubaix Cedex1 France
Editeur (trice) B. BOUTTEVILLETéléphone 03.20.81.50.01
Fax 03.20.81.50.19Email [email protected]
AMBIANCE 54W / AMBIANCE / Courbes isophotes (E, perpendiculaire)
Valeurs en Lux, Echelle 1 : 24Position de la surface dans la pièce:Point marqué:(-1.500 m, 0.000 m, 0.850 m)
Trame: 16 x 16 Points
Emoy [lx] Emin [lx] Emax [lx] Emin / Emoy Emin / Emax
119 53 199 0.444 0.266
Page 7
1
T5 1 x 24 W
MEDIVA T5
13.12.2016
TRATO - TLV
22 rue Molière BP36959057 Roubaix Cedex1 France
Editeur (trice) B. BOUTTEVILLETéléphone 03.20.81.50.01
Fax 03.20.81.50.19Email [email protected]
LECTURE 24W / LECTURE / Courbes isophotes (E, perpendiculaire)
Valeurs en Lux, Echelle 1 : 3Position de la surface dans la pièce:Point marqué:(-0.150 m, -1.039 m, 1.245 m)
Trame: 8 x 8 Points
Emoy [lx] Emin [lx] Emax [lx] Emin / Emoy Emin / Emax
343 311 362 0.907 0.860
Page 11
2
General and reading lighting combined
MEDIVA T5
13.12.2016
TRATO - TLV
22 rue Molière BP36959057 Roubaix Cedex1 France
Editeur (trice) B. BOUTTEVILLETéléphone 03.20.81.50.01
Fax 03.20.81.50.19Email [email protected]
SOINS / SOINS / Courbes isophotes (E, perpendiculaire)
Valeurs en Lux, Echelle 1 : 16Position de la surface dans la pièce:Point marqué:(-0.450 m, -2.100 m, 0.800 m)
Trame: 16 x 32 Points
Emoy [lx] Emin [lx] Emax [lx] Emin / Emoy Emin / Emax
336 155 597 0.462 0.260
Page 15
3
Consumption 61 W 27 W 88 W
Average lighting 119 lx 343 lx 336 lx
LED 4 Ft module
MEDIVA EVO LED
13.12.2016
TRATO - TLV
22 rue Molière BP36959057 Roubaix Cedex1 France
Editeur (trice) B. BOUTTEVILLETéléphone 03.20.81.50.01
Fax 03.20.81.50.19Email [email protected]
AMBIANCE 4FT / AMBIANCE / Courbes isophotes (E, perpendiculaire)
Valeurs en Lux, Echelle 1 : 24Position de la surface dans la pièce:Point marqué:(-1.500 m, 0.000 m, 0.850 m)
Trame: 16 x 16 Points
Emoy [lx] Emin [lx] Emax [lx] Emin / Emoy Emin / Emax
136 62 238 0.459 0.262
Page 7
1
2 Ft module
MEDIVA EVO LED
13.12.2016
TRATO - TLV
22 rue Molière BP36959057 Roubaix Cedex1 France
Editeur (trice) B. BOUTTEVILLETéléphone 03.20.81.50.01
Fax 03.20.81.50.19Email [email protected]
LECTURE 2 FT / LECTURE / Courbes isophotes (E, perpendiculaire)
Valeurs en Lux, Echelle 1 : 3Position de la surface dans la pièce:Point marqué:(-0.150 m, -1.039 m, 1.245 m)
Trame: 8 x 8 Points
Emoy [lx] Emin [lx] Emax [lx] Emin / Emoy Emin / Emax
346 323 358 0.933 0.902
Page 11
2
General and reading lighting combined
MEDIVA EVO LED
13.12.2016
TRATO - TLV
22 rue Molière BP36959057 Roubaix Cedex1 France
Editeur (trice) B. BOUTTEVILLETéléphone 03.20.81.50.01
Fax 03.20.81.50.19Email [email protected]
SOINS / SOINS / Courbes isophotes (E, perpendiculaire)
Valeurs en Lux, Echelle 1 : 16Position de la surface dans la pièce:Point marqué:(-0.450 m, -2.100 m, 0.800 m)
Trame: 16 x 32 Points
Emoy [lx] Emin [lx] Emax [lx] Emin / Emoy Emin / Emax
409 172 828 0.419 0.207
Page 15
3
Consumption 42,1 W - 31% 13,8 W - 49% 55,9 W - 36,5%
Average lighting 136 lx 346 lx 409 lx
7 www.tlv-healthcare.com
All sp
ecific
ation
s her
ein a
re p
rovid
ed fo
r inf
orm
ation
pur
pose
s only
and
may
be
mod
ified
by T
LV w
ithou
t not
ice.(D
) - U
pdat
e (J
J/M
M/A
A) :
13/0
3/20
18
22, rue Molière, BP 369 59057 Roubaix (Lille) - Cedex 1, FranceTel : + 33 (0)3 20 81 50 00 - Fax : + 33 (0)3 20 81 50 19 - www.tlv-healthcare.com
MADE IN FRANCE
• EN ISO 9001 and EN ISO 13485: Quality management systems
• CE Medical Devices Marking according to 93/42/EEC Directive
• EN ISO 11197: Medical supply units
• EN ISO 7396-1: Medical gas pipeline systems - Part 1
• European rules for caring centers lighting
Norms & certifications
Bed head units, Wall lighting units, Ceiling pendants, Suspended Beams & Columns,
Special care bed head units, Sealed lightings, Medical gas monitoring & Biomedical Accessories