Page 1: mend that you keep the instructions in a safe · mend that you keep the instructions in a safe place, so you may refer to them when needed. Humidifier B300 offers a combined function
Page 2: mend that you keep the instructions in a safe · mend that you keep the instructions in a safe place, so you may refer to them when needed. Humidifier B300 offers a combined function

Dear Customer,

thank you for having chosen the Humidifier B300. Please read the operating instructionscarefully before using your new unit. We recom-mend that you keep the instructions in a safeplace, so you may refer to them when needed.

Humidifier B300 offers a combined function – itcleans, purifies, and humidifies the air. If onlythe humidifying function is needed, the air purify-ing function can be reduced by removing the airfilters in the suction area, which, however, doeslead to a considerable increase of the evaporati-on performance. The function of the UV-lampremains in the operating mode.

We hope that you enjoy your Humidity B 300unit.P r i n c i p l e o f O p e r a t i o n

With this unit, you have purchased a highly effec-tive humidifier and air purifier that offers you allthe advantages of today’s high-tech appliances.With the proper humidity level, you are not onlyprotecting your health, but also prevent dama-ging of valuable furnishings, storage goods orprevent product loss when humidity-sensitiveproduction processes are involved. The unit isoperated with regular tap water and functionscompletely free of condensation. The minimalpower consumption makes it an environmentalfriendly device.

The Humidifier B 300 works on the principle ofnatural evaporation. Thereby the humidifying andpurifying process works as described in the fol-lowing:The B 300 draws in the air through an air suctionopening on the side of the power cable and pas-ses it through an air filter, which filters out thelarger dust particles and fine particles. In theinner chamber of the humidifier, the drawn-in airis treated with germicidal UV-C rays and thanpassed on to the vapor filter. The vapor filter,which continuously glides through the water-bath, produces with its special structure a largeevaporation surface. This causes the air to becleaned one more time. After the humidificationand purification, the air is returned back into theroom. The Humidifier B300 thereby works basedon the principle of circulating air, meaning thatair in a closed room is drawn in, cleaned, andmoistened time after time until the humidity levelset has been reached. The measuring of the roomhumidity thereby takes place through a humiditysensor with a 2 meter cable. Displaying of theroom humidity and the setting of the desiredhumidity takes place through the operating dis-play. This is where you can also regulate the fanspeed.

12 Disconnect the mains plug before opening the equipment!

1 .

2 .

3 .

Moduletechnical element

Module housing

Module water reservoir

With zipper,

easy to remove

filter mat

3 - m o d u l e s t r u c t u r e

Page 3: mend that you keep the instructions in a safe · mend that you keep the instructions in a safe place, so you may refer to them when needed. Humidifier B300 offers a combined function

Disconnect the mains plug before opening the equipment! 13

S a f e t y I n s t r u c t i o n s /Wa r n i n g

Children do not recognize the dangers, whichcan develop while handling electrical applian-ces. Therefore do never leave children unsu-pervised when running electrical appliances; The unit may be operated only by authorizedpersons; Never operate an appliance with defectivepower input;Make sure that electrical parts do not comeinto contact with water;The appliance is not exposed to influence ofthe weather (rain, snow, frost); also Do not operate the unit with wet hands; The unit is set up stable and horizontally ontothe ground;When absent for a longer time, always pullthe power supply plug or ensure that thepower supply is disconnected; Before cleaning, always first pull the powersupply plug; Never pull the unit or the power cable at thepower inlet, when pulling the power supplyplug out of the socket; Never move the unit in a filled condition.Water can exit causing damages to the unit orfurnishings;Service work, for which tools have to be used,may only be performed by the authorized per-sonnel.

Before operating your unit, you should ensurethat all parts are installed appropriately and thatthe water reservoir is filled. Please proceed asfollows:

l

l

l

l

l

l

l

l

l

l

l

l

l

l

l

l

l

S e t u p / L o c a t i o n

O p e r a t i n g y o u r u n i t

Open the packaging and remove all packagingparts from the humidifier.Setup the unit onto an even, horizontal surface. For an optimal function, the unit may be setup near a heat resource. However, the tempe-rature in that area should not exceed 70° C. Check the unit for any possible transportationdamages.Check whether the delivery is complete, andthat all parts belonging to the unit are fittedproperly.

Check whether local mains voltage is the sameas the one on the identification label. The identi-fication label is located above the power/net inletcable and below the fan motor. To locate thelabel, you first have to remove the outer case ofthe unit.

P o w e r S u p p l y

The operating display of the B 300 informs youabout the current condition of the unit. You canread the room humidity, the set fan level, and thewater level. By using the switches + /- and AIR,you can input the settings for your unit.

The indicator display and setting of the relativehumidity takes place in 5% increments.Therefore, the values may deviate when usingother control devices. At 3 and 8, the displayjumps over to the next higher value (e.g. actualhumidity = 43% corresponds to =45%)

The user can, to a minor degree (+/- 5%), cali-brate the display accuracy. Read more about thisin the Paragraph "Adjusting the humidityIndicator"

O p e ra t i n g t h e Hu m i d i f i e r B 3 0 0

Page 4: mend that you keep the instructions in a safe · mend that you keep the instructions in a safe place, so you may refer to them when needed. Humidifier B300 offers a combined function

14 Disconnect the mains plug before opening the equipment!

S w i t c h i n g o f O n / O f f a n ds e t t i n g o f t h e f a n l e v e l –A I R S w i t c h

The B 300 is switched on or off by pressing theAIR-button twice. By repeatedly depressing theswitch, the different fan modes can be changed

If the AIR-key is pressed, the symbol on the indica-tor display starts to blink and, after pressing theswitch again, jumps to the next operating mode. Bydepressing the AIR-switch again, the status can bechanged to the next mode. In this condition, thesymbol blinks until the desired status is reachedand for 2 seconds, another setting was not selec-ted. After that, the symbol no longer blinks, and theselected operation mode is performed. Please notethat when the AIR-key is depressed the first time,only the setting mode is started and the operatingmode does not change. Only by depressing the AIR-switch again, the operating modus is changed.

Standby:

-LOW:

-HIGH:

AUTO:

The humidifier is switched off andwithout function. Attention: The unitstill receives power.

The fan runs on the lowest outputlevel. The noise level is optimized

The fan runs on the highest outputlevel, for a maximum output of humi-dity and air purification.

The fan runs automatically accordingto the performance requirements,which is controlled by the actual roomhumidity.

C h a n g i n g o f t h e – H U M I D I T Y- S w i t c h

If the unit is turned on, with the humidity keys +/-the desired relative humidity can be changedupward or downward. During the pressing of thekeys "+" or "-" the indicator jumps from the actualroom humidity to the desired value according tothe setting. By repeatedly pressing the + or –switch, the value is accordingly changed. If thedesired value is adjusted, the indicator displayjumps back after few seconds to the actual roomhumidity and the new desired value was recordedand stored.

To lock the control keys for children or strangers,to disable the use of the operating panel, is inte-grated. It is switched on and/or deactivated bysimultaneous pressing of the 3 keys (AIR KEYand the two HUMIDITY keys) for 3 seconds. If thekey disabling device is activated and a key ispressed, all control elements in the display blink.The key lock must be deactivated. Only afterpressing the 3 keys again, the settings can bechanged.

F u n c t i o n " S w i t c h / k e y l o c k "

The unit is equipped with two micro switches,which, when opening the casing of the unit, swit-ches via the control all components of the B 300off. The disconnection via the micro switch is sig-naled via a flashing STAND-BY indicator. Only ifthe casing is completely closed, the Standby indi-cator turns off and the air humidifier takes upagain operations.

S a f e t y o f t h e u n i t

To fill the water reservoir of the B 300, switch offthe unit as described above. The indicator in thedisplay helps you to determine the correct level.Now open the lateral filler flap on the right or leftside (see fig. 1). Grab the flap at the grip aboveand pull it up to the stop outward. Now you fill upthe tank to the water level as indicated on thedisplay, using a suitable container (e.g. wateringcan or similar).

It is important that you do not spill water aroundthe unit or overfill the humidifier. The exitingwater can damage your furnishings or your unit.

F i l l i n g t h e t a n k

Page 5: mend that you keep the instructions in a safe · mend that you keep the instructions in a safe place, so you may refer to them when needed. Humidifier B300 offers a combined function

Disconnect the mains plug before opening the equipment! 15

The connection to the local water line networkmust take place via a specialist, e.g. a certifiedplumber. (Please comply with the regulations ofthe local water supply company). A return flowstop may be recommendable) for the connectionbetween unit and water pipeline, we recommendour 1,5m long safety pressure hose (Art. No.1754). The automatic water supply takes placecontrolled by a solenoid valve (water inlet). Theunit comes standardized with the water supplyset automatically on a max. of 12 liters. Thismeans that after the fill level has reached 12liters, the water supply shuts off. The controllingof the water supply takes place via the electrodebars of the water level indicator. For a perfectfunctioning of the automatic water supply, theelectrode bars must be cleaned regularly with asponge to free them from lime and dirt deposits.

Accessory Water Supply (AWS)

To guarantee an optimal functioning and a longlifetime of your B 300 unit, repair and mainten-ance are inevitable. Depending on the conditionsin the room environment, (air and water quality),the need for repair and maintenance can differ(see the table maintenance intervals). The requi-red works are described systematically in the fol-lowing chapter.

For all works on the unit, always unplug thehumidifier or otherwise make sure thatpower to the unit is off!

R e p a i r a n d M a i n t e n a n c e

To perform various maintenance works, first thecasing must be opened. Although the unit doesprovide for an automatic switch-off, when thecasing is opened, to insure safety, the powershould be turned off and/or the power supplyshould be pulled.

For the opening of the casing, remove the lockclips at the upper and lower side of the humidi-fier. Now the two halves of the casing can be pul-led open in both arrow directions (see picturebelow). Handle the casing parts with care so thatthey are not damaged.

Now you can also remove the technical module. Toremove the module, lift it completely upwards. Forreinserting the technical module, slide it into theunit along the on the bottom of the water reservoirlocated gliding mechanism. Attention: check thetension of the blue vapor filter; it can increaseduring the procedure. The tension can be increasedprior to the maintenance procedure by means of thetension pulley delivered with the unit.

The reassembling takes place in reverse order. Firstslide one half of the casing on the water reservoirup to the center of the unit. Afterwards the secondhalf of the casing is assembled likewise onto the tuband pushed toward the center.

O p e n i n g t h e C a s i n g

Accessories: Water guard

Water faucetPower outlet (socket)

Schuko

Adapter

Plug

Power Plug

Humidifier

Gasket Acoustic

Alarm

Operating

Indicator

Membrane

Valve

Gasket

in Place

Safety

Pressure

Hose

Sensor - position

horizontally onto

the ground

Page 6: mend that you keep the instructions in a safe · mend that you keep the instructions in a safe place, so you may refer to them when needed. Humidifier B300 offers a combined function

16 Disconnect the mains plug before opening the equipment!

Now you can snap the lock clips. Make sure that alllock clips are locked securely.

Attention: When mounting the casing half, it isimportant that the orientation is followed correctly.See the recess for the power cable.

C h a n g i n g t h e F i l t e r s

Air cleaning filterTo change the air-cleaning filter, the casing hasto be opened first (for instructions see the chap-ter about Opening the Casing). Now the air-clea-ning filter can be removed by hand from its posi-tion. It is important that no residue remain. Once the old filter is completely removed, thenew filter (Art. No. 6361) can be inserted.Position the new filter into the same place as theold one. It is important that filter does not inter-fere with the rotor blades of the fan. In addition,the filter edges should not extend outward.

Vapor FilterFor a comfortable changing of the filter, werecommend to keep the water level as low aspossible.

First, open the casing (for instructions see thechapter about Opening the Casing). The old vapor filter can now be removed in thatyou either open or cut the zipper. Remove the fil-ter completely. Check the water reservoir for anyresidue, and if present remove it. Dispose of theold filter fleece into the residual waste.

Now remove the tension pulley (see illustration).You can now start with the inserting of the newfilter (Art. No. 6360) as shown on the picture.Close the zipper and check the tension. If it issufficient, you can close the casing as describedin the previous chapter. If the tension is not suf-ficient, insert the tension pulley and repeat theprocess as described above.

Double-sided

air flow

Air cleaning filter

Vapor Filter

Page 7: mend that you keep the instructions in a safe · mend that you keep the instructions in a safe place, so you may refer to them when needed. Humidifier B300 offers a combined function

The change of the UV lamp should take place viaauthorized technical personnel. For all work on theunit pull the power supply plugs or ensure that thepower is disconnected! For changing the UVC lamp,the casing is opened as described before and thetechnical unit is taken out of the water tank.Afterwards the cover of the technical unit is unscr-ewed and the screws at the bulb socket of the UVlamp are removed. Now the UV lamp can be pulledout to the rear. Pull the defective lamp from itssocket and insert the new UVC lamp (Art. No.:6210). Afterwards you push the lamp back againinto the UVC protecting glass (Art. No. 6212), Fitthe socket with the existing screws and close thecover of the technical unit. Please also examine thesurrounding parts during the exchange of the UVClamp such as the UV protecting glass and the seal(Art. No. 6213) of the UVC lamp. If you shoulddetermine damages, the unit may be operated againonly after having exchanged the defective part.

Please dispose the defective UVC lamp in the samemanner as fluorescent tubes according to the spe-cific local regulations of your domicile.

Adjusting the humidity indicator

An authorized specialist should perform theadjustment. The Humidifier B 300 offers the pos-sibility to adjust the indication of the relativehumidity within a range of +/- 5% of the actualvalue, and thereby to adapt the display to otherdevices or measures. Please note that there is amicroclimate in each zone of a room area andtherefore the different value displayed from oneunit to another unit or appliance, is possible andcorrect. For adjustment/calibration, proceed asfollows: l opening the casing as described in the section" opening the casing " l with a small screwdriver, carefully turn theadjustment pot (potentiometer). It is locatedunderneath the circuit board and is accessible bya hole in the casing at the operating panel. Youshould make the adjustment in several steps, i.e.make only a small turn at the potentiometer, andcheck the result at the display. If the desiredresult should not be reached yet, turn againcarefully at the potentiometer. l Close casing after adjustment.

Cleaning of your Humidifier B 300

Every 3-4 months the unit should be cleanedfrom lime arrears and contamination (dependenton the site conditions: Water hardness dusty con-dition air quality). For this procedure, the casingis opened as in picture ".." (See also chapter onOpening the Casing). The cleaning can be accom-plished with commercial cleaning agents. Do notuse benzene or other solvents that can damageplastics! To remove lime residues please use thelime remover of the brand Brune (Art. No. 9016)or a commercial lime remover. All cleaning agentresidues must be completely removed (rinse wellwith clear water), since otherwise a foaming ofthe cleaning agents can damage the unit.

If the unit is not operated for a longer time, theresidual water is to be emptied and the tension ofthe vapor filter is to be decreased (see the chap-ter on Changing Vapor Filter). Additionally, theunit should be cleaned. A basic cleaning should take place annually (pos-sibly by our maintenance service).

Changing of the UVC Lamp

Disconnect the mains plug before opening the equipment! 17

Page 8: mend that you keep the instructions in a safe · mend that you keep the instructions in a safe place, so you may refer to them when needed. Humidifier B300 offers a combined function

The following listed maintenance works should beperformed in the indicated time intervals. For allmaintenance or repair, always pull the power supp-ly plug or ensure that the power supply is dis-connected!

M a i n t e n a n c e i n t e r v a l s

Power supply: 230V ACPerformance: max. 58 WFuse: 2 ASafety check: CECapacity of water reservoir: approx. 25 LAir performance max. (free blowing): 600 m3/hVapor performance max. 1.4 L/hLength of power cord: 2.5 mWeight (w/out water): 21 kgMeasurement (W x H x D): 74 x 71 x 41 cm

Te c h n i c a l D a t a

18 Disconnect the mains plug before opening the equipment!

da

ily

Maintenance intervals Work to be performed

3-5

we

ek

s12

mo

nth

s

l

l

l

l

l

l

l

l

Water level: check via the display. The unit shuts off automatically, whenempty (not applicable for units with automatic water supply)

Humidity level: check via the digital indicator (display).

Casing: check for dirt (dust in the air take-in area, etc.), if necessaryremoveAir filter, check and if necessary change (only use original parts of theBrune brand). The filter should be changed no later than 20 weeks afterinitial operation. Vapor filter, check and if necessary change, (only use original parts of theBrune brand). The filter should be changed no later than 20 weeks afterinitial operation. Cleaning of the water reservoir (see chapter on Opening Casing).Important: when using Water-Fresh avoid over dosing. Electrode bars: check for dirt and lime residue (if necessary clean with asponge and the appropriate cleaning agents) Vapor filter fleece: check for sufficient tension (see chapter Changing Filters)

l

l

l

l

l

l

l

perform complete cleaning of the unitchange air suction filter change vapor filterclean copper electrodescheck UVC-Lamp clean glass of the UVCFor changing the UVC lamp, see chapter on Changing UVC lamp (normal operation time approx. 5000 hours)

The indicated time intervals apply to normal water quality and normal dust accumulation and may varyaccordingly.

Page 9: mend that you keep the instructions in a safe · mend that you keep the instructions in a safe place, so you may refer to them when needed. Humidifier B300 offers a combined function

E r r o r C o r r e c t i o n

Disconnect the mains plug before opening the equipment! 19

Cause Solution

Not functioning at all(no standby indicator)

No Function(Standby –Symbolblinks)

Water level indicatormissing

Unit runs, but vaporfilter does not move

Unit leaks water

Automatic water supplyhas stopped

Automatic water supplyruns uninterrupted

Water guard gives acoustic signal

Unit not connected topower supply

Fine-fuse of the circuitboard blown

Micro switch deactivatedunit

Water level too low

Copper electrodes dirty

Tension too low

Vapor filter rubs againstcasing

Check water reservoir fordamages

Safety pressure hosedefect – water supply isstopped automatically

Water inlet valve (solenoidvalve) does not close

Water leaks

Check power input

Replace fine-fuse of the circuit board

Check casing that it is completely locked

refill water

Clean copper electrodes

Increase tension, see"Changing of Filters"If still too low, replace vaporfilter. Possibly exchange driving roller.

Increase tension see "Changingof Filters"If still too low, replace

Replace water reservoir

Replace hose

-Dirt residue in the water feed tube-check Electrodes for pollutants-Replace solenoid valve

Check for the cause. Cut offsupply for water guard fromthe net for some seconds

Error

Page 10: mend that you keep the instructions in a safe · mend that you keep the instructions in a safe place, so you may refer to them when needed. Humidifier B300 offers a combined function
Page 11: mend that you keep the instructions in a safe · mend that you keep the instructions in a safe place, so you may refer to them when needed. Humidifier B300 offers a combined function

Water-Fresh is best suitable for all humidifiers,which work according to the evaporator princi-ple. It prevents alga formation and decreaseslime deposits in the unit. Water-fresh is nottransferred to the room air, and, if appropriatelyapplied, does not harm your health. It is availa-ble as 1-liter bottle (order number 9020) or 5-liter canister (order number 9022) with a mea-suring cup.

With the use of water-freshly please only useexactly the amount as indicated in the instruc-tions (25 ml to 10 liters of water). An overdosingcan cause foaming and thus damage the electro-nic elements of the unit. The residual water con-tainer with up-graded concentrations of Water-Fresh should also be emptied regularly. UseBiocides safely. Before using, please read theproduction information carefully.

These operating instructions contain the necessaryinformation for the intended use, the correct opera-tion, and adequate maintenance of the equipment.

The knowledge of and the complying with theinstructions contained in these operating instruc-tions are a condition for the safe use as well as forthe safety during operation and maintenance.

These operating instructions cannot take into con-sideration of each conceivable use. The unit and theaccessories are designed for private and commerci-al use.

In addition, we point out that the contents of theseoperating instructions are not part of an earlier orexisting agreement, promise, or a legal relation oramendment of the original. All obligations of BruneLuftbefeuchtung Proklima GmbH are as specified inthe respective sales contract, which also containsthe complete and solely valid warranty conditions.These contractual warranties are neither extendednor limited by the statements in these operatinginstructions. The operating instructions containinformation, which is protected by copyright. Photocopying or translating into another language is notpermitted without previous written permission byBrune Luftbefeuchtung Proklima GmbH.

These operating instructions have been translatedfor your convenience. In case of conflict, the origi-nal operating instructions in the German languageshall be applicable.

Wa t e r - F r e s h

L e g a l N o t i c e

Disconnect the mains plug before opening the equipment! 21

Optima Lime ScaleSolventThe higly concentrated LimeScale Solvent is especiallysuitable for air humidifiersand for all sanitary areassuch as WC, showers, swim-ming pools, bath-rooms, etc.It is based on phosphoricacid and is odour free with-out acrid fumes.

Application: 100 - 1000grams of Optima to 10 litresof water. For heavy staininguse pure and immediatelyrinse abundantly with water. Read safety instructionsbefore use.

Opt ima

Page 12: mend that you keep the instructions in a safe · mend that you keep the instructions in a safe place, so you may refer to them when needed. Humidifier B300 offers a combined function

www.b rune . i n f o · ma i l@brune . i n f o

Luftbefeuchtung Prokl ima GmbH

Luftbefeuchtung Proklima GmbH · Schwarzacher Str. 13 · D-74858 Aglasterhausen