methods+materials speaker - mark jacobson (kuraray), facades+ nyc 2016

21
Laminated Glass: Changing the Face of Glass Railing Design Mark Jacobson, Kuraray Interlayer Solutions

Upload: the-architects-newspaper

Post on 29-Jul-2016

223 views

Category:

Documents


1 download

DESCRIPTION

 

TRANSCRIPT

Page 1: Methods+Materials Speaker - Mark Jacobson (Kuraray), Facades+ NYC 2016

Laminated Glass:

Changing the Face of Glass Railing Design

Mark Jacobson, Kuraray Interlayer Solutions

Page 2: Methods+Materials Speaker - Mark Jacobson (Kuraray), Facades+ NYC 2016

Kuraray Interlayer Solutions Two Companies Combined to Create Broadest Interlayer

Portfolio

GLS

§  Acquired from DuPont in June, 2014

§  An inventor of PVB and the inventor of SentryGlas® ionoplast interlayer

§  Americas leader in architectural interlayers

TROSIFOL/PVB §  Part of Kuraray since 2004

§  Global technology leader in PVB resin and vinyl acetate chain

§  European leader in architectural interlayer

§  Clearest PVB on the market and broad range of specialties and colors

May 11, 2016 Kuraray Interlayer Solutions 2

Building a global leader in the Laminated Glass Market

Page 3: Methods+Materials Speaker - Mark Jacobson (Kuraray), Facades+ NYC 2016

Kuraray Interlayer Solutions

May 11, 2016 Kuraray Interlayer Solutions 3

We supply the broadest portfolio of PVB and Ionoplast interlayers for laminated glass

Page 4: Methods+Materials Speaker - Mark Jacobson (Kuraray), Facades+ NYC 2016

General introduction to Glass Railings

May 11, 2016 Kuraray Interlayer Solutions 4

Page 5: Methods+Materials Speaker - Mark Jacobson (Kuraray), Facades+ NYC 2016

Glass Balustrades are Functional

§ Structurally support hand rails § Provide safety from falling

from elevated surfaces

May 11, 2016 Kuraray Interlayer Solutions 5

Page 6: Methods+Materials Speaker - Mark Jacobson (Kuraray), Facades+ NYC 2016

Glass for Aesthetics and Visibility

§ Glass is desirable for aesthetics

§ Clear, clean appearance § Excellent site lines

May 11, 2016 Kuraray Interlayer Solutions 6

Page 7: Methods+Materials Speaker - Mark Jacobson (Kuraray), Facades+ NYC 2016

Code Changes

May 11, 2016 Kuraray Interlayer Solutions 7

Page 8: Methods+Materials Speaker - Mark Jacobson (Kuraray), Facades+ NYC 2016

IBC Prior to 2015

§  Glass used as a handrail assembly or guard section shall be constructed of either single fully tempered glass, laminated fully tempered glass or laminated heat strengthened glass.

§  Glazing in railing in-fill panels shall be of an approved safety glazing material.

§  For all glazing types, the minimum nominal thickness shall be ¼”.

§  Fully tempered glass and laminated glass shall comply with Category II of CPSC 16CFR 1201 or Class A of ANSI Z97.1.

§  Problem – Single fully tempered glass can break and fall out!

May 11, 2016 Kuraray Interlayer Solutions 8

Page 9: Methods+Materials Speaker - Mark Jacobson (Kuraray), Facades+ NYC 2016

Potential for Glass Breakage with Monolithic Glass

§  Inclusions §  Removal of top rail §  Product design §  Installation issues §  Building movement §  Construction process §  Laminated glass option – value engineered §  Heat soaking not 100% effective

May 11, 2016 Kuraray Interlayer Solutions 9

Page 10: Methods+Materials Speaker - Mark Jacobson (Kuraray), Facades+ NYC 2016

IBC 2015 Requirement

•  Glass used in a handrail, guardrail or a guard section shall be laminated glass constructed of fully tempered or heat-strengthened glass and shall comply with Category II or CPSC 16CFR Part 1201 or Class A of ANSI Z97.1.

•  Glazing in railing in-fill panels shall be of an approved safety glazing material that conforms to the provisions of Section 2406.1.1. For all glazing types, the minimum nominal thickness shall be ¼ inch (6.4 mm). §  Exception – Single fully tempered glass complying with Category II of CPSC 16

CFR Part 1201 or Class A of ANSI Z97.1 shall be permitted to be used in handrails and guardrails where there is no walking surface beneath them or the walking surface is permanently protected from the risk of falling glass.

May 11, 2016 Kuraray Interlayer Solutions 10

Page 11: Methods+Materials Speaker - Mark Jacobson (Kuraray), Facades+ NYC 2016

Top Rails and Guards

§  Glass balusters shall not be installed without an attached handrail or guard.

§  Exception: A top rail shall not be required where the glass balusters are laminated glass with two or more glass plies of equal thickness and the same glass type when approved by the building official.

§  Question – should next revision of code be revised to remove subjectivity of building official by including post-glass-breakage performance?

§  Consider ASTM E2353 for post-glass-breakage requirement.

Page 12: Methods+Materials Speaker - Mark Jacobson (Kuraray), Facades+ NYC 2016

Key properties to consider in laminated glass

May 11, 2016 Kuraray Interlayer Solutions 12

Page 13: Methods+Materials Speaker - Mark Jacobson (Kuraray), Facades+ NYC 2016

Stiffness and Strength

•  Ionoplast laminates show superior strength properties

•  Figure shows strength relative to PVB laminate

•  Good opportunities to reduce glass thickness especially for thicker laminates

•  Data below from C.R. Laurence website

Pure Bending

Nominal Laminate Thickness (mm)

0 5 10 15 20 25 30 35 40

Stre

ngth

Rel

ativ

e to

PV

B L

amin

ate

0.4

0.6

0.8

1.0

1.2

1.4

1.6

SentryGlas(R) PlusPVB ReferenceEVASafe(TM)

T = 23oC1.52 mm Interlayer

Laminate Dimension = 2m

System Lite1Interlayercaliper

Interlayertype Lite2

LineloadkN/m

ConcentratedloadkN/m

UniformloadkN/m2

LineDeflec=on(mm)

Conc.Deflec=on(mm)

L56S10F 6 1.52SG 6 0.36 0.25 0.5 16.7 11.3

L56S10F 6 1.52PVB 6 0.36 0.25 0.5 31.5 19.9

Page 14: Methods+Materials Speaker - Mark Jacobson (Kuraray), Facades+ NYC 2016

Exposed edge durability

•  SentryGlas® Ionoplast laminate’s ability over time to resist the formation of defects along the edge as a result of temperature and humidity

•  PVB laminates are durable, but moisture sensitive

Page 15: Methods+Materials Speaker - Mark Jacobson (Kuraray), Facades+ NYC 2016

Quality and installation considerations with laminated

glass

May 11, 2016 Kuraray Interlayer Solutions 15

Page 16: Methods+Materials Speaker - Mark Jacobson (Kuraray), Facades+ NYC 2016

Edge Alignment and Finish

§  ASTM C1172 for laminated glass –  Refer to section 8.5.3, “For some laminated

applications, such as, point supported glass and balustrades, where the edges of the laminate are exposed, tighter length and width tolerances may be requested by the customer. Consult the supplier to determine their capabilities.”

§  In addition to edge alignment, consider edge “smoothness” with respect to interlayer being flush with the glass edges.

May 11, 2016 Kuraray Interlayer Solutions 16

Page 17: Methods+Materials Speaker - Mark Jacobson (Kuraray), Facades+ NYC 2016

Installation Methods

Wet Glaze •  Setting Block protects edge of glass from

metal contact. •  Glass is secured in place with

•  Portland Cement §  Not recommended for Laminated

Glass •  Grout

§  Gypsum based §  Okay with laminated but deteriorates

with water infiltration, so only interior applications

•  Epoxy §  More costly §  Adherence to glass could limit

expansion resulting in failure •  Polyurethane

§  More costly

Dry Glaze •  Simpler installation •  No waiting for grout to set •  Able to do inclines without damming

top of shoe •  No chemical reaction with laminated

glass •  Requires drainage for exterior

applications.

May 11, 2016 Kuraray Interlayer Solutions 17

Page 18: Methods+Materials Speaker - Mark Jacobson (Kuraray), Facades+ NYC 2016

Glass Breakage Demonstration

§ Will break laminate with PVB and with SentryGlas®

§ Glass supplied by J.E. Berkowitz

May 11, 2016 Kuraray Interlayer Solutions 18

Page 19: Methods+Materials Speaker - Mark Jacobson (Kuraray), Facades+ NYC 2016

Breakage Characteristics

Page 20: Methods+Materials Speaker - Mark Jacobson (Kuraray), Facades+ NYC 2016

Conclusions

§  Glass railings add beauty and are aesthetically pleasing in architectural application

§  Code changes are driving most glass railing applications to laminated glass

§  Consideration should be given to specifying glass edges as well as installation methods to accommodate differences of laminated glass vs. monolithic glass.

§  SentryGlas® interlayers provide additional post-glass breakage safety and edge stability

May 11, 2016 Kuraray Interlayer Solutions 20

Page 21: Methods+Materials Speaker - Mark Jacobson (Kuraray), Facades+ NYC 2016

Thank You Kuraray Interlayer Solutions

Your global Partner for Laminated Safety Glass