UNIT III
ADVANCES IN METROLOGY
Basic concept of lasers Advantages of lasers – laser Interferometers – types – DC and AC Lasers interferometer – Applications – Straightness – Alignment. Basic concept of CMM – Types of CMM – Constructional features – Probes – Accessories – Software – Applications – Basic concepts of Machine Vision System – Element – Applications.
![Page 3: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/3.jpg)
UNIT III
ADVANCES IN METROLOGY
Laser & Interferometers
CMM
Machine Vision System
![Page 4: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/4.jpg)
LASER &
INTERFEROMETERS
![Page 5: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/5.jpg)
LASER
LIGHT AMPLIFICATION BY STIMULATED
EMISSION OF RADIATION.
Why Laser instruments used ?
Laser Instruments are devices to produce
powerful, monochromatic collimated beam of
light in which the waves are coherent.
![Page 6: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/6.jpg)
PRINCIPLE OF LASER
PRINCIPLE: When photon emitted during
stimulated emission has the same energy, phase &
frequency as the incident photon.
Photon comes in contact with another atom or
molecule in high energy level E2, then it will cause the
atom to return to ground state energy level E1 by
releasing another photon.
The sequence of triggered identical photon from
stimulated atom is known as stimulated emission.
![Page 7: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/7.jpg)
PRINCIPLE OF LASER
This multiplication of photon through
stimulated emission leads to coherent,
powerful monochromatic, collimated beam
of light emission. This light emission is called
LASER.
![Page 8: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/8.jpg)
BASIC CONCEPTS OF LIGHT
Distance between two trough
or crest are called
WAVELENGTH λ.
Time taken to travel one
wavelength λ is called time
period T.
Maximum disturbance of wave
is called amplitude (A).
Velocity of transmission is (
λ/T )
(1/T) is called Frequency.
![Page 9: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/9.jpg)
LASER
Helium-Neon Laser source produces a 1 to 2 mm diameter
beam of pure red light having power of 1 MW. So, Very High
Intensity.
Laser is used for Interferometry.
Upto a great distance beam has no divergence , then it begins
expand at rate of about 1 mm/m.
Is visible & it can be observed easily. Its accuracy is of 1 mm
over 2 m.
Used for very accurate instruments in the order of 0.1
micron in 100m.
![Page 10: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/10.jpg)
LASER METROLOGY
Commercially, It is projected onto position detector which is used for the method of alignment.
It is very convenient, collimated & high intensity source used, because for its Precision, Accuracy, No Contact and Hot moving parts.,
Laser diodes, Semiconductor lasers – More advantages, Lower cost.
Laser instruments – In surface Inspection & Dimensional Measurements.
![Page 11: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/11.jpg)
LASER TELEMETRIC SYSTEM
Is a non contact gauge with a collimated laser
beam.
Measuring Rate – 150 Scans Per Second.
Three Components – Transmitter, Receiver,
Processor Electronics
![Page 12: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/12.jpg)
LASER TELEMETRIC SYSTEM
TRANSMITTER – Produces a collimated parallel
scanning laser moving at high constant linear
speed. It appears as red line after scanning.
TRANSMITTER Components :
Low power helium neon gas laser.
Synchronous motor.
Collimating lens.
Reflector prism.
Synchronous pulse photo detector.
Replaceable Window.
![Page 13: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/13.jpg)
SCHEMATIC DIAGRAM OF LASER
TELEMETRIC SYSTEM
![Page 14: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/14.jpg)
ADVANTAGES
Possible to detect changes in dimensions when product
is in continuous processes.
There is no need to wait for measuring in hot
conditions.
Applied on production machines & controlled with
closed feedback loops.
Possible to write programs for microprocessor to take
care of smoke, dust & other airborne interference
around the work piece being measured.
![Page 15: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/15.jpg)
LASER & LED BASED DISTANCE
MEASURING INSTRUMENTS
Can measure 1 to 2 m with accuracy of order of 0.1 to 1 % of measuring range.
It has two distance meter at equal distance on either side of object & control unit to measure thickness of object.
The angle at which the light enters the detector will change the distance between measuring head & object is changed.
Change in angle of deviation is measured & calibrated in terms of distance.
![Page 16: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/16.jpg)
LASER & LED BASED DISTANCE MEASURING
INSTRUMENTS - ADVANTAGES
These types of instruments are very reliable
because there is no moving part.
Instrument response time is in milliseconds.
The output is provided
as 0 – 20 mA.
![Page 17: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/17.jpg)
SCANNING LASER GAUGE
Used for Dimensional Measurements.
Has Transmitter, Receiver & Processor Electronics.
ADVANTAGES :
Accuracy of ±0.25 micron for 10-50mm diameter
objects.
It is used for objects of 0.05mm to 450mm diameter.
![Page 18: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/18.jpg)
SCANNING LASER GAUGE
![Page 19: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/19.jpg)
PHOTODIODE ARRAY IMAGING
Used for dimensional measurements.
Stationary part shadow is projected on a
solid state diode array image sensor.
Has four parts :
Laser source
Imaging optics
Photodiode array
Signal processor & Display unit
![Page 20: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/20.jpg)
PHOTODIODE ARRAY IMAGING
ADVANTAGES
Used for large parts, two arrays.
Measurement accuracy is as high as
±0.05 micron.
![Page 21: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/21.jpg)
DIFFRACTION PATTERN
TECHNIQUE
Used in dimensional measurements.
Parallel coherent laser beam is diffracted by
a small part & resultant pattern is focused by
lens on a linear diode array.
Distance between alternating light & dark
bands in diffraction pattern is direct function
of wire diameter, laser beam wavelength &
Lens focal length.
![Page 22: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/22.jpg)
DIFFRACTION PATTERN
TECHNIQUE
ADVANTAGES
Used to measure small gaps & small
diameter parts.
Measurement accuracy is more for smaller
parts.
DISADVANTAGES
Not suitable for large diameters.
![Page 23: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/23.jpg)
LASER TRIANGULATION SENSORS
For Dimensional
Measurements.
Quick Deviation
Measurement due to
Surface Change.
Perform Automatic
Calculation on Shell
Metal Stampings.
Can measure Bore
Diameter using 2 Sensor.
![Page 24: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/24.jpg)
INTERFEROMETRY - BASICS
When light is made to interfere, it produces a pattern
of dark bands, which corresponds to a very accurate
scale of divisions.
A ray having a single frequency and wavelength is
produced generally known as monochromatic light.
This monochromatic light is used for measuring
flatness and determining the length of slip gauges.
It is the basic principle of interferometry.
![Page 25: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/25.jpg)
LASER USES IN INTERFEROMETRY
To find accurate measurement of length.
Reduces time & Skill requirement like other
methods used for finding the length.
The Laser Measurement accuracy is order of
0.1µm in 100m.
In modified laser designs, a single frequency is
selected from the coherent beam and used for
interferometric measurement.
![Page 26: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/26.jpg)
TWO FREQUENCY LASER
INTERFEROMETER
Two Frequency Laser Head
Beam Directing and Splitting Optics
Measurements optics
Receivers
Wavelength Compensators
Electronic Receivers
![Page 27: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/27.jpg)
TWO FREQUENCY LASER
INTERFEROMETER
![Page 28: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/28.jpg)
TWO FREQUENCY LASER
INTERFEROMETER - ADVANTAGES
For Measuring Linear Positioning, Straightness
in two planes.
High Sensitivity.
Free from Noise Disturbances ( Light, Electrical
Noise, Air turbulence).
Use of Single photo detector / Measurement
axis, Sensitivity to Optical Alignment is Less.
![Page 29: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/29.jpg)
GAUGING WIRE DIAMETER FROM
DIFFRATION PATTERN USING LASER
![Page 30: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/30.jpg)
LENGTH MEASUREMENT USING
FRINGE COUNTING
Incoherent Laser Beam illuminates three slits at
a time in the first plane which form Inference
fringes.
Fringe movement is determined by detector on
the other side of short length of grating.
The number of slits in the first plane is governed
by length over which measurement is required.
![Page 31: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/31.jpg)
LENGTH MEASUREMENT
USING FRINGE COUNTING
![Page 32: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/32.jpg)
LENGTH MEASUREMENT
USING FRINGE COUNTING
Using He-Ne laser at 0.63µm a fringe
spacing of 1µm will be obtained at 1.4µm
from the slits, if a separation of 1µm is used.
The spacing between the slits & distance of
the slit to the plane of grating depend on the
wavelength of the light used.
![Page 33: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/33.jpg)
ADVANTAGES
Accurate measurements over relatively
short distances.
Wire diameters from 0.005 to 0.2mm
can be measured.
![Page 34: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/34.jpg)
LASER INTERFEROMETRY
COMPONENTS
Two frequency laser source.
Optical elements.
Laser heads measurement receiver.
Measurement display.
![Page 35: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/35.jpg)
TWO FREQUENCY LASER SOURCE
Generally, It becomes He-Ne type that generates
stable coherent light beams of two frequencies.
One is Polarized vertically and other one is
polarized horizontally relative to the plane of the
moving feet.
Laser slightly oscillates at two frequencies by a
cylindrical permanent magnet around the cavity.
![Page 36: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/36.jpg)
TWO FREQUENCY LASER SOURCE
Beam containing both frequencies passes
through a quarter wave & half wave plates
which change the circular polarization, or
vertical and other horizontal.
Linearly polarized beam is expanded in a
collimating telescope, after which most of the
beam is transmitted through a 45 degree beam
splitter and one of the laser head.
![Page 37: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/37.jpg)
OPTICAL ELEMENTS
The various optical elements are :
Beam Splitters
Beam Benders.
Retro reflectors.
![Page 38: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/38.jpg)
BEAM SPLITTERS
Used to divide the laser beam into separate
beams along different axes.
Possible to adjust the splitted laser’s output
intensity by having a choice of beam splitter
reflectivities.
![Page 39: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/39.jpg)
BEAM SPLITTERS USAGE ( DIVIDING EQUAL LASER OUTPUT )
![Page 40: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/40.jpg)
BEAM BENDERS
Used to deflect the light beam around
corners on it path from the laser to each axis.
Beam benders are just flat mirrors, but having
absolutely flat and very high reflectivity.
Normally, the 90 degree beam deflection is
avoided for not to disturb the polarizing
vectors.
![Page 41: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/41.jpg)
RETRO REFLECTORS
They are plane mirrors, roof prisms or cube
corners.
Cube corners are three mutually perpendicular
plane mirrors, and reflected beam is always
parallel to the incident beam in these devices.
In AC laser interferometer measurements, two
retro reflectors are used.
When plane mirror is used as retro reflectors in
plane mirror interferometer, it must be flat with
in 0.06 micron / cm.
![Page 42: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/42.jpg)
LASER HEAD’S MEASUREMENT
RECEIVER
Used to detect the part of the returning beam
as F1 – F2 and a Doppler shifted frequency
component del f.
![Page 43: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/43.jpg)
MEASUREMENT DISPLAY
Has microcomputer to compute & display results.
Signals from reference receiver & measurement
receiver located in the laser head are counted in two
separate pulse counters and subtracted.
Other input signals for correction are temperature
co-efficient of expansions.
Air velocity is also displayed.
![Page 44: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/44.jpg)
AC LASER INTERFEROMETER
TYPES
Standard Interferometer
Single Beam Interferometer
![Page 45: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/45.jpg)
STANDARD INTERFEROMETER
![Page 46: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/46.jpg)
STANDARD INTERFEROMETER
The displacement is measured between the
interferometer & cube corner.
Measurement retro reflector for this
interferometer is a cube corner.
It is least expensive and can be used wherever
it is possible.
![Page 47: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/47.jpg)
SINGLE BEAM INTERFEROMETER
![Page 48: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/48.jpg)
SINGLE BEAM INTERFEROMETER
• As same as standard interferometer.
• Has outgoing and returning beam super
imposed on each other, giving the appearance if
only one beam travelling between the
interferometer and the retro reflector.
• Very much suitable when space for optics and
beam path is minimum.
![Page 49: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/49.jpg)
LASER INTERFEROMETER
Uses AC Laser as light source.
Enable to measure over longer distance.
Laser – Monochromatic optical energy, (
Collimated into a directional beam ) – Exact
wavelength – Pure for highly accurate
measurements.
Utilize the principles of both optical
techniques & digital electronics.
![Page 50: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/50.jpg)
AC LASER INTERFEROMETER
![Page 51: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/51.jpg)
COMPONENTS – LASER
INTERFEROMETER
Two frequency zeeman laser.
Beam splitters.
Fixed internal cube corners.
External cube corners.
Photo detectors.
Amplifiers.
Pulse converter.
![Page 52: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/52.jpg)
COMPONENTS – LASER
INTERFEROMETER
Two Frequency Zeeman Laser :He-Ne type
Beam Splitters : Adjust Output based on Reflectivities
Cube corners : Fixed & Movable external –Used to reflect
the laser beam
Photo detectors : To change beam splitters signal to electrical
signal
Amplifiers : Used to separate frequency difference.
Pulse converter : Used to extracts change in frequency.
![Page 53: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/53.jpg)
MICHELSON INTERFEROMETER
Consists of monochromatic light source, a beam
splitter & two mirrors.
PRINCIPLE : Constructive & Destructive
Interference when one mirror remains fixed and
the other is moved.
Monochromatic Light from an extended source
falls on a beam splitter which splits the rays into
two equal rays of same intensity at right angles.
![Page 54: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/54.jpg)
MICHELSON INTERFEROMETER
![Page 55: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/55.jpg)
MICHELSON INTERFEROMETER
If both mirrors are kept at same distance from
beam splitter, the observer will see bright spot
due to constructive interference.
If Movable mirror M1, shifted by quarter ( half )
wavelength, then the beam will be returned to
observer 180 deg out of phase ( 360 deg in phase )
and darkness will observed due to destructive
interference.
![Page 56: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/56.jpg)
MICHELSON INTERFEROMETER
IMPROVING CONDITIONS
Use of laser light for measuring longer distance.
Instead of using mirror the cube corner
reflector is suited for reflecting the light.
Photocells can be employed to convert light
intensity variation in voltage pulses to given
direction of position change.
![Page 57: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/57.jpg)
DUAL FREQUENCY LASER
INTERFEROMETER
Used to measure displacement, high
precision measurement of lengths, angles and
refractive indices as well as derived static
and dynamic quantities.
![Page 58: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/58.jpg)
DUAL FREQUENCY LASER
INTERFEROMETER - CONSTRUCTION
![Page 59: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/59.jpg)
DUAL FREQUENCY LASER
INTERFEROMETER - WORKING
Laser source generates two frequencies. F1 & F2
Reference signal F1-F2 is detected in Photo detector
P2.
Measuring signal F1-F2 +- Del F for X(Y) direction by
photo detector P3(P4).
Environment correction is made by photo detector P1.
![Page 60: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/60.jpg)
DUAL FREQUENCY LASER
INTERFEROMETER
![Page 61: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/61.jpg)
DUAL FREQUENCY LASER
INTERFEROMETER -
APPLICATIONS
Used for both incremental displacement and
angle measurements.
Resolution 2nm in 10m measuring range.
![Page 62: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/62.jpg)
TWYMAN – GREEN
INTERFEROMETER
Used as polarizing interferometer with variable
amplitude balancing between sample and reference
waves.
For exact test surface measurement, the instrument
error can be determined by absolute measurement.
This error is compensated by storing the same in
microprocessor system & subtracting from the test
surface measurement.
![Page 63: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/63.jpg)
TWYMAN – GREEN
INTERFEROMETER ADVANTAGES
Permits testing of surface with wide varying
reflectivity.
Avoids undesirable feed back of light reflected
of the tested surface & instrument optics.
Enables utilization of the maximum available
energy.
Polarisation permits phase variation to be
effected with the necessary precision.
![Page 64: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/64.jpg)
LASER INTERFEROMETER APPLICATIONS
LINEAR MEASUREMENT
![Page 65: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/65.jpg)
LASER INTERFEROMETER APPLICATIONS
ANGULAR MEASUREMENT
![Page 66: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/66.jpg)
MACHINE TOOL METROLOGY
Component parts accuracy depends on machine tool
accuracy.Parts quality depends on,
Rigidity & Stiffness of machine tool & its components.
Alignment of various components in relation to one
another.
Quality & Accuracy of the control devices and the
driving mechanism.
![Page 67: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/67.jpg)
ALIGNMENT ACCURACY OF
MACHINE TOOL CHECKED BY
Geometrical Test :
Dimensions, Position and Displacement of
Component relative to one another are checked.
Static Test
Dynamic Test
Practical Test :
Test pieces are machined in machines. Test
pieces must be approximate to fundamental
purpose for which machine has been designed.
![Page 68: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/68.jpg)
PURPOSE OF MACHINE TOOL
TESTING
Dimensions of any work piece, its surface &
geometry depend on machine tool accuracy
for its manufacture.
In mass production, various components
produced should be of high accuracy &
assemble to be on non-sensitive basis.
![Page 69: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/69.jpg)
GEOMETRICAL CHECKS ON MACHINE
TOOL Straightness.
Flatness.
Parallelism, Equidistance & Coincidence.
Squareness of straight line & plane.
Rotations
Out of round.
Eccentricity.
Run out.
Periodical axial slip.
Camming.
![Page 70: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/70.jpg)
GEOMETRICAL CHECKS ON
MACHINE TOOL
Movement of all the working components.
Spindle test for
Concentricity.
Axial slip.
Accuracy of axis & position.
![Page 71: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/71.jpg)
LASER EQUIPMENT FOR ALIGNMENT
TESTING
Particularly suitable in aircraft production , shipbuilding etc., ( Flatness testing, Squareness checking etc., )
Consist of Laser of 10mm dia, Auto reflector.,
Laser has Helium-Neon Plasma Tube in heavy aluminum cylindrical housing.
Laser beam comes from its centre & parallel to housing within 10” of arc & alignment stability is of order of 0.2” of arc/hour.
![Page 72: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/72.jpg)
LASER EQUIPMENT FOR ALIGNMENT
TESTING
Auto reflector consists of detector head & read
out unit.
No. of photocell are arranged to compare laser
beam in each half horizontally & vertically.
Detect the alignment of flat surfaces
perpendicular to a reference line of slight.
![Page 73: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/73.jpg)
MACHINE TOOLS TEST
Test for level of installation of machine tool in
horizontal & vertical planes.
Tests for perpendicularity of guide ways to other
guide ways.
Test for flatness of machine bed & for
straightness & parallelism of bed ways on bearing
surface.
Test for true running of main spindle & its axis
movements.
![Page 74: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/74.jpg)
MACHINE TOOLS TESTS
Test for line of movement of various members
like spindle, tables & cross slides.
Test for parallelism of spindle axis to guide
ways or bearing surfaces.
![Page 75: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/75.jpg)
ALIGNMENT TESTS ON LATHE
Levelling of the machine.
True running of locating cylinder of main spindle.
Axial slip of main spindle & true running of
shoulder face of spindle nose.
True running of headstock center.
Parallelism of main spindle to saddle movement.
True running of taper socket in main spindle.
![Page 76: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/76.jpg)
ALIGNMENT TESTS ON LATHE
Movement of upper slide parallel with main spindle
in vertical plane.
Parallelism of tailstock guide ways with the
movement of carriage.
Parallelism of tailstock sleeve taper socket to saddle
movement.
Pitch accuracy of lead screw.
Alignment of lead screw bearings with respect to
each other.
![Page 77: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/77.jpg)
LEVELLING OF THE MACHINE
Done by sensitive spirit level.
Saddle is approximately kept in centre of the
bed support feet.
![Page 78: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/78.jpg)
TRUE RUNNING OF LOCATING CYLINDER
OF MAIN SPINDLE
• Locating cylinder is provided to locate the chuck / face plate.
• Locating surface should be in cylindrical shape.
• Dial indicator is fixed to carriage & indicator feeler touches locating surface.
• Surface is rotated on its axis & indicator should not show any spindle movement.
![Page 79: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/79.jpg)
![Page 80: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/80.jpg)
![Page 81: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/81.jpg)
![Page 82: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/82.jpg)
![Page 83: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/83.jpg)
![Page 84: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/84.jpg)
![Page 85: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/85.jpg)
![Page 86: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/86.jpg)
![Page 87: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/87.jpg)
ALIGNMENT TESTS ON MILLING
MACHINE
Cutter spindle axial slip or float.
Eccentricity of external diameter.
True running if internal taper.
Surface parallel with longitudinal movement.
Traverse movement parallel with spindle axis.
Centre T-slot Square with the arbor.
Tests on column.
Over arm parallel with spindle.
![Page 88: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/88.jpg)
![Page 89: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/89.jpg)
![Page 90: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/90.jpg)
![Page 91: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/91.jpg)
![Page 92: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/92.jpg)
![Page 93: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/93.jpg)
![Page 94: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/94.jpg)
ALIGNMENT TESTS ON PILLAR
TYPE DRILLING MACHINE
Flatness of clamping surface of base.
Flatness of clamping surface of table.
Perpendicularity of drill head guide to the base plate.
Perpendicularity of drill head guide with plate.
True running of spindle taper.
Parallelism of the spindle axis with its vertical
movement.
Squareness of clamping surface of table to its axis.
Total deflection.
![Page 95: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/95.jpg)
![Page 96: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/96.jpg)
![Page 97: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/97.jpg)
![Page 98: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/98.jpg)
![Page 99: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/99.jpg)
ACCEPTANCE TESTS FOR
SURFACE GRINDERS
Table top parallel to its movement by attaching the dial gauge in the stationary spindle and dial feeler touching the table top and traversing the table.
Spindle axis parallel to table top by fitting dial gauge on redial arm of the spindle & its feeler touching the square testing on table.
Slots parallel to table movement by fitting the dial gauge in the stationary spindle & dial feeler touching the slot & traversing the table.
![Page 100: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/100.jpg)
ACCEPTANCE TESTS FOR
SURFACE GRINDERS
Vertical movement of the spindle square with
table top by fitting dial gauge in spindle & its
feeler touching the square resting on table.
Spindle axis square with the slot by fitting dial
gauge on an arm fitted to spindle & rotating
the spindle & rotating the spindle by 180 deg.
Practical tests.
![Page 101: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/101.jpg)
CO ORDINATE
MEASURING MACHINE
![Page 102: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/102.jpg)
CONTENTS
INTRODUCTION
TYPES OF MEASURING MACHINE
CMM AND TYPES OF CMM
PROBE
FEATURES
APPLICATION
ADVANTAGES
DISADVANTAGES
![Page 103: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/103.jpg)
INTRODUCTION
Measuring machines are used for measurement
length over the outer surface of the length bar or
any long member.
The member may be either rounded or flat or parallel.
Measuring are more useful and advantages that
vernier calipers, micrometer etc..,
![Page 104: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/104.jpg)
TYPES OF MEASURING MACHINE
Length bar measuring machine
New all measuring machine (spirit level)
Universal measuring machine (all)
Co-ordinate measuring machine
Computer controlled co-ordinate measuring machine
(inspect & measure)
![Page 105: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/105.jpg)
CO ORDINATE MEASURING
MACHINE
Co-ordinate measuring machine is also called as CMM.
CMM is used for contact inspection the parts. When it is used for
computer integrated manufacturing, the CMM by computer
numerical control method.
A coordinate measuring Machine is a 3D device For measuring the
Physical geometrical Characteristics of an object.
CMM has movements in three axis .
This machine may be manually controlled by an operator or it may
be computer controlled.
![Page 106: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/106.jpg)
BLOCK DIAGRAM OF THE
ELEMENTS OF A CMM
CO-ORDINATE
MEASURING
MACHINE
DIGITAL
READ OUT COMPUTER
SOFTWARE PROBING
SYSTEM
![Page 107: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/107.jpg)
ELEMENTS OF CMM
A basic Co-ordinate Measuring Machine consists of four
elements.
The machine structure which is basically an X-Y-Z
positioning device.
The Probing system use to collect raw data on the part and
provide input to the control system.
Machine Control and Computer hardware.
The Software for three dimensional analysis.
![Page 108: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/108.jpg)
CMM – BASIC PARTS
![Page 109: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/109.jpg)
Description The typical 3 "bridge" CMM is composed of three axes, an X, Y and Z. These axes are orthogonal to each other in a typical three dimensional coordinate system. Each axis has a scale system that indicates the location of that axis. The machine will read the input from the touch probe, as directed by the operator or programmer. The machine then uses the X,Y,Z coordinates of each of these points to determine size and position with micrometer precision typically. Reference
![Page 110: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/110.jpg)
![Page 111: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/111.jpg)
FEATRUES OF CNC - CMM
![Page 112: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/112.jpg)
According to control system
Manual CMM
CNC CMM or DCC CMM
According to design of main structure
CANTILEVER
MOVING BRIDGE
FIXED BRIDGE
HORIZONTAL ARM
GANTRY
COLUMN
According to mounting style
Bench top
Free Standing
Portable and Hand Held
TYPES OF CMM
![Page 113: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/113.jpg)
Cantilever type
• A vertical probe moves in the z-axis • Carried by a cantilevered arm that moves in
the y-axis • This arm also moves laterally through the x-
axis • Two configuration: fixed table and movable
table
• Advantage- a fixed table allows good accessibility to the work piece
• Required small floor space
• Disadvantage- the bending caused by the cantilever design
• Suitable for measuring long, thin part
![Page 114: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/114.jpg)
Moving bridge type
• Most widely used
• Has stationary table to support work piece to be measured and a moving bridge
• Stationary table and movable bridge: Allows high table load
• Advantage- reduce bending effect
• Disadvantage- with this design, the phenomenon of yawing can occur- affect the accuracy
![Page 115: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/115.jpg)
Fixed bridge type
• Most widely used CMM
• In the fixed bridge configuration, provides better accuracy and rigidity.
• Disadvantage : Limited accessibility caused by the bridge
• Stationary bridge and movable table Leads to small measuring uncecertainty
![Page 116: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/116.jpg)
Column type
• Often referred to as universal measuring machine instead of CMM
• The column type CMM construction provides exceptional rigidity and accuracy
• These machines are usually reserved for gauge rooms rather than production floor.
![Page 117: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/117.jpg)
Horizontal arm type
• Have very large measuring range and low power consumption.
• Maximum accessibility has been achieved • Also referred to as layout machine
• Type of CMM: Moving arm and Moving Table
• Advantage- provides a large area, unobstructed
work area
• Ideal configuration for measurement of automobile parts
![Page 118: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/118.jpg)
Gantry type
• supported by four vertical columns rising from the floor
• Employed three movable component moving along mutually perpendicular giudeways
• This setup allows you to walk along the work piece with the probe, which is helpful for extremely large pieces
• Used in measuring car body and wind tunnel Model
![Page 119: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/119.jpg)
Gantry configuration with dual linear motor drives, laser scales an online compensation
![Page 120: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/120.jpg)
According to mounting style
Bench top
Mounted on a bench or deck. Most CMM are this type
Free Standing
These machines can support themselves and do not required mounting
Portable and Hand Held
Moved freely and used almost anywhere
![Page 121: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/121.jpg)
ADVANTAGES OF CMM
Flexibility
Reduced Setup Time
Single Setup
Improved Accuracy
Reduced Operator Influence
Improved Productivity
![Page 122: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/122.jpg)
DISADVANTAGES OF CMM
The probe may not be in perfect alignment.
The probe may have run out.
The probe may moving in Z-axis may have
some perpendicular error.
There may have errors in digital system.
![Page 123: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/123.jpg)
Common Applications
• Dimensional measurement
• Profile measurement
• Angularity or orientation
• Depth mapping
• Digitizing or imaging
• Shaft measurement
![Page 124: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/124.jpg)
FEATURES CMM SOFTWARE
Measurement of the diameter, center
distance, length
Measurement of plane and spatial curves.
Minimum CNC program
Data communication
Digital input and output command
Interface CAD software
![Page 125: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/125.jpg)
PROBE or Sensors
The measuring head that contact the job to
inspect and measure is called as probe.
The different kinds of probes like taper tip, ball
tip etc..,
The function of a CMM is to acquire information
about the measurand, usually in the form of
Cartesian coordinates. The devices used to explore
the area to generate this information are the
"sensors".
![Page 126: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/126.jpg)
126
PROBE or Sensors • Two types of sensors:
“Tactile” sensors.
“Noncontact” sensors or "optoelectronic" sensors
• Tactile sensors distinguish:
“Rigid” or hard or fixed sensors .
“Point to point” or touch trigger sensors.
“Continuous” or measuring type or displacement sensors
• In non contact sensors ,Two main principles are used:
Triangulation 3D
Time of Flight
![Page 127: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/127.jpg)
127
Sensors Tactile Sensor
Characteristic elements of a generic, tactile, fixed probing system
1. Co-ordinate measuring
machine ram (or spindle).
2. Probe extension.
3. Probe changing system.
4. Probe.
5. Stylus changing system
6. Stylus extension
7. Stylus shaft.
8. Stylus.
9. Stylus tip.
10. Tip diameter.
11. Generic, fixed probing system.
12. Stylus system (composed of
stylus system components).
![Page 128: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/128.jpg)
128
Sensors The Rigid Sensor
Point measurement by means of a spherical rigid sensors
• Rigid sensor: “Touch finger” constituted by a shaft for the fitting of the touch
finger in the CMM probe holder.
• On the opposite extremity has either a sphere or a cone.
![Page 129: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/129.jpg)
129
Sensors Point to Point Tactile Sensors
• The point to point type of measurement determines the position of points by
bringing in physical contact the tip of the sensors with the part and then
retracting.
• The point to point measurement represents a fast ideal solution to define
Dimension and Position.
Probing (point measurement) sequences
Legend:
1......: Starting point.
2......: Point probing.
3......: Disengagement
after point probing
![Page 130: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/130.jpg)
130
Point to Point Tactile Sensors • Tactile sensors for point to point measurement are based on “Isostatic
support” concept.
• The spring still keeps the contact closed. the force of contact balances the force of the spring itself.
• Just before that the balance between the forces is reached, the force of contact between part and sensor causes a slight displacement of the stylus and the contact is opened.
• A signal is generated that allows the recording of the co-ordinates of the sphere centre at the moment of contacting the part surface. The point has been measured.
Isostatic support tactile sensor
The CMM starts to decelerate, while the spring preloaded mechanism follows the machine movement with a slight over-travel. Finally the machine retracts and the Isostatic support assumes its resting position in an extremely repeatable mode, ready to measure more points.
![Page 131: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/131.jpg)
131
Sensors Continuous Tactile Sensors
Probing sequence in continuous measurement
• In the point to point measurement the sensor gets in contact with the part to be measured.
• In continuous measurement the sensor remains in contact with the part
• follows its profile and measuring points according to pre-determined laws in a single measuring path.
• Very accurate and relatively larger than point to point, the continuous sensors, can supply very complete information on the form of the measured feature.
![Page 132: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/132.jpg)
132
Sensors Non Contact Sensors
• The non-contact sensors are based on optoelectronic techniques. These
types of sensors can measure an object without physical contact with it.
• the non-contact measurement technology allows:
To measure very small pieces not otherwise measurable.
For a faster measurement than a touch sensor.
To measure very soft pieces of material not otherwise measurable.
• Noncontact sensors are based on two principles
3D Triangulation Principle
Time of Flight Principle
![Page 133: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/133.jpg)
133
Sensors Non contact sensor:3D Triangulation Principle
• It is a principle based on noncontact sensor.
• When object point C is lit by the laser, the
point becomes visible to the camera. Distance d between the laser source and the camera .
• the orientation a of the laser are known.
• line CB is determined by connecting the lens center to the image of point C in the image plane and finding its angle with line AB.
• In triangle ABC, by knowing d and angles a and b the position of point C on the object can be determined.
• Increasing angle g will increase depth accuracy, but that will increase self-occlusion, making determination of depth impossible.
The triangulation principle.
![Page 134: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/134.jpg)
134
Continued… • Angle gamma determines the quantization accuracy of the scanner.
• When this angle is zero, objects at different depths cannot be distinguished from each other.
![Page 135: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/135.jpg)
135
Sensors Non contact sensor: Time of Flight Principle
• The Time of Flight scanner is used to scan and investigate with laser light.
• The scanner rangefinder determines the distance from work surface by noting down the timing of round trip of the light pulse.
• The laser when emits light pulse detector has timed the reflected light.
• If c is known speed of light. If round-trip time t is known, then distance is (c* t)/2.
•
line of reference shown applications
![Page 136: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/136.jpg)
MACHINE VISION
SYSTEM
![Page 137: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/137.jpg)
MACHINE VISION SYSTEMS
Machine Vision::Computer Vision::Intelligent Vision
Automated Inspection of Manufactured products for Quality
and Process Control.
Definition:
Means of electro-optically simulating the image
recognition capabilities of the human eye/brain.
![Page 138: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/138.jpg)
PRINCIPLE OF WORKING
Image Formation
Processing of image
Defining and Analysis of Image
Image interpretation and Decision Making
![Page 139: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/139.jpg)
OVERVIEW OF MACHINE VISION PROCESS
![Page 140: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/140.jpg)
FUNCTIONING OF
MACHINE VISION
SYSTEM
![Page 141: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/141.jpg)
STEPS IN MACHINE VISION
SYSTEM Image Formation
Back Lighting
Diffused Front Lighting
Processing of image
Windowing
Image restoration
Defining and Analysis of Image
Distance measurement
Object orientation
Defining Object position
Image interpretation and Decision Making
![Page 142: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/142.jpg)
CCD CAMERA
A CHARGE-COUPLED DEVICE (CCD) is a
sensor for recording images, consisting of an
integrated circuit containing an array capacitors.
![Page 143: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/143.jpg)
MACHINE VISION SYSTEM
APPLICATION FIELDS
Inspection
Part Identification
Guidance and Control
![Page 144: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/144.jpg)
HUMAN VS MACHINE VISION
HUMAN VISION
Recognition
Hand-eye coordination
Inspection
Find Position
Gather Information
Safety
MACHINE VISION
Identification
Robot guidance
Inspection
Find position
Measure
![Page 145: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/145.jpg)
HUMAN VS MACHINE VISION
HUMAN VISION
Human Vision
High image resolution
Interprets complex scene
quickly
Operates in visible light
spectrum
MACHINE VISION
Machine Vision
Consistent, tireless
Operate in visible Infrared,
X-ray.
Operates in hostile
environments
Follows program precisely
![Page 146: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/146.jpg)
MACHINE VISION APPLICATIONS
IN-LINE
Checking each item that passes the camera
RANDOM
Checking one item out of a series as it passes the camera on
the production line, and
OFF-LINE
Take an item off the production line for a test in a quality
assurance laboratory.
![Page 147: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/147.jpg)
WHERE IS MACHINE VISION USED?
Semiconductor
Electronic
Automotive
Container
Pharmaceutical
Medical device
Plastic
Chemicals
Food
Footwear
Textiles
Printing
Wood / Forest
Fabricated Metal
![Page 148: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/148.jpg)
WHY USE MACHINE VISION?
High speed production lines
Microscopic inspection
Clean room environments
Hazardous environments
Closed -loop process control
Robot guidance
Precise non-contact measurement
![Page 149: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/149.jpg)
WHAT CAN MACHINE VISION DO?
PRESENCE - ABSENCE CHECKING,
ASSEMBLY VERIFICATION
Verify that part components are present and in the correct
locations
Dimensional Gauging
Calculate the distance between two or more points on an object
Defect detection
Identify defects and calculate defect characteristics such as position and size
![Page 150: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/150.jpg)
ASSEMBLY VERIFICATION
DEFECT DETECTION
Golden Template Image Image with Defects Difference Image
GAUGING
![Page 151: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/151.jpg)
ADVANTAGES
Lower inventories.
Fewer production overruns.
Reduced labor costs.
Less rework and production.
Avoidance of inspection bottlenecks.
Elimination of adding value to scrap conditions
![Page 152: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/152.jpg)
ELIMINATES
Cost of Recruiting and Training.
Scrap - Rework created while learning a new job.
Average workers' compensation paid for injuries.
Average Educational grant per employee.
Personnel - Payroll department costs per employee
![Page 153: METROLOGY AND MEASUREMENTS UNIT III](https://reader034.vdocuments.net/reader034/viewer/2022042510/563dba83550346aa9aa644db/html5/thumbnails/153.jpg)
RESULT
Increased Market share.
Improved Customer satisfaction and lower warranty costs.
Penetration of New Niche Markets.
Pricing flexibility and participation in price Elastic markets.