miniveyor conveyor oven -...
TRANSCRIPT
�
®®
®®
®
MINIVEYOR MULTI-PURPOSE OVEN
MODEL210HX, 214HX Series
Installation and Operation
Instructions2M-HG0104 Rev. J 1/18/2012
214HX
ALL MODELS
22
These symbols are intended to alert the user to the presence ofimportant operating and maintenance instructions in the manualaccompanying the appliance.
RETAIN THIS MANUAL FOR FUTURE REFERENCENOTICE
Using any part other than genuine Star factory supplied parts relieves themanufacturer of all liability.Star reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes,improvements, additions or replacements for previously purchasedequipment.Due to periodic changes in designs, methods, procedures, policies andregulations, the specifications contained in this sheet are subject to change without notice. While Star International Holdings Inc., Company exercises good faith efforts to provide information that is accurate, we are not responsible for errors or omissions in information provided or conclusionsreached as a result of using the specifications. By using the information provided, the user assumes all risks in connection with such use.
MAINTENANCE AND REPAIRSContact your local authorized service agent for service or required maintenance. Please record the model number, serial number, voltage and purchase date in the area below and have it ready when you call to ensure a faster service.
SAFETY SYMBOL
Model No.
Serial No.
Voltage
Purchase Date
Business 8:00 am to 4:30 p.m. Central Standard TimeHours:
Telephone: (314) 678-6303
Fax: (314) 781-2714
E-mail [email protected] [email protected]
Website: www.star-mfg.com
Service Help Desk
Authorized Service Agent ListingReference the listing provided with the unit orfor an updated listing go to:Website: www.star-mfg.com E-mail [email protected]
Mailing Address: Star International Holdings Inc., Company 10 Sunnen Drive St. Louis, MO 63143 U.S.A
�
SPECIFICATIONS 210HX-120V -60Hz Rating/Connection: 1,700WattsNEMAPlug: 5-15P, CUL5-20PElectricalSupply: Separateserviceperoven-14.2Amp,120VAC,60HzApproximateWeight(210HXOvenwithLegs):Installed-61.5Lbs(28kg),Shipping-39.5Lbs(18kg) Dimensions: Width: 4611/16"(118.6cm)-OvenwithShelves Depth: 157/16"(39.2cm) Height: 14"(35.5cm)-SingleOvenwithLegs
210HX-208V -60Hz Rating/Connection: 2,800WattsNEMAPlug: 6-20P ElectricalSupply: Separateserviceperoven-13.5Amp,208VAC,60HzApproximateWeight(210HXOvenwithLegs):Installed-61.5Lbs(28kg),Shipping-39.5Lbs(18kg) Dimensions: Width: 4611/16"(118.6cm)-OvenwithShelves Depth: 157/16"(39.2cm) Height: 14"(35.5cm)-SingleOvenwithLegs
210HX-220V -50Hz Rating/Connection: 2,800WattsNEMAPlug: CE-16ACord ElectricalSupply: Separateserviceperoven-12.7Amp,220VAC,50HzApproximateWeight(210HXOvenwithLegs):Installed-61.5Lbs(28kg),Shipping-39.5Lbs(18kg) Dimensions: Width: 4611/16"(118.6cm)-OvenwithShelves Depth: 157/16"(39.2cm) Height: 14"(35.5cm)-SingleOvenwithLegs
210HX-240V -60&50Hz Rating/Connection: 2,800WattsNEMAPlug: 6-20P CE-16ACordElectricalSupply: Separateserviceperoven-11.7Amp,240VAC,60Hz&50HzApproximateWeight(210HXOvenwithLegs):Installed-61.5Lbs(28kg),Shipping-39.5Lbs(18kg) Dimensions: Width: 4611/16"(118.6cm)-OvenwithShelves Depth: 157/16"(39.2cm) Height: 14"(35.5cm)-SingleOvenwithLegs
214HX-208V -60Hz Rating/Connection: 4,000WattsNEMAPlug: 6-30P ElectricalSupply: Separateserviceperoven-19.3Amp,208VAC,60HzApproximateWeight(214HXOvenwithLegs):Installed-77.5Lbs(31kg),Shipping-44.5Lbs(20kg) Dimensions: Width: 4611/16"(118.6cm)-OvenwithShelves,48 3/16" (122.4 cm) 214HXETB Depth: 197/16"(39.2cm) Height: 14"(35.5cm)-SingleOvenwithLegs
214HX-220V -50Hz Rating/Connection: 4,000WattsNEMAPlug: N/A ElectricalSupply: Separateserviceperoven-18.2Amp,220VAC,50HzApproximateWeight(214HXOvenwithLegs):Installed-77.5Lbs(31kg),Shipping-44.5Lbs(20kg) Dimensions: Width: 4611/16"(118.6cm)-OvenwithShelves Depth: 197/16"(39.2cm) Height: 14"(35.5cm)-SingleOvenwithLegs
214HX-240V -60&50Hz Rating/Connection: 4,000WattsNEMAPlug: 6-30P CE-16ACordElectricalSupply: Separateserviceperoven-16.7Amp,240VAC,60Hz&50HzApproximateWeight(214HXOvenwithLegs):Installed-77.5Lbs(31kg),Shipping-44.5Lbs(20kg) Dimensions: Width: 4611/16"(118.6cm)-OvenwithShelves,48 3/16" (122.4 cm) 214HXETB Depth: 197/16"(39.2cm) Height: 14"(35.5cm)-SingleOvenwithLegs
CheckwithfactoryforCEapprovedmodels.
4
GENERALINSTALLATIONDATAThisequipmentisdesignedandsoldforcommercialuseonlybypersonneltrainedandexperiencedinitsoperationandisnotsoldforconsumeruseinandaroundthehomenorforusedirectlybythegeneralpublicinfoodservicelocations.Beforeusingyournewequipment,readandunderstandalltheinstructions&labelsassociatedwiththeunitpriortoputtingitintooperation.Makesureallpeopleassociatedwithitsuseunderstandtheunitsoperation&safetybeforetheyusetheunit.Allshippingcontainersshouldbecheckedforfreightdamagebothvisibleandconcealed.Thisunithasbeentestedandcarefullypackagedtoinsuredeliveryofyourunitinperfectcondition.Ifequipmentisreceivedindamagedcondition,eitherapparentorconcealed,aclaimmustbemadewiththedeliveringcarrier.Concealeddamageorloss-ifdamageorlossisnotapparentuntilafterequipmentisunpacked,arequestforinspectionofconcealeddamagemustbemadewithcarrierwithin15days.Becertaintoretainallcontentsplusexternalandinternalpackagingmaterialsforinspection.Thecarrierwillmakeaninspectionandwillsupplynecessaryclaimforms.
INSPECTION&ASSEMBLYUNCRATINGANDINSPECTINGUnpacktheunitandcomponentsfromtheshippingcontainer.Removeallvisiblepackingmaterial and those from inside the cooking chamber. If damage is discovered, file a claim immediatelywiththecarrierthathandledtheshipment.Donotoperatetheunitifitwasdamagedduringshipping.Thefollowingshouldbeincluded:MiniveyorMulti-PurposeOven,StainlessSteelLoadUp&UnloadTrays,4StainlessSteelLegs.
REMOVEALLHEATINGELEMENTSHIPPINGSUPPORTSPRIORTOPLACINGYOURUNITINTOOPERATION.ASSEMBLYANDINSTALLATIONThe unit was shipped with certain assembly required, plug into a standard outlet specified for its voltage and amp draw. If improper electrical supply is determined, contact a qualified electrician priortousingtheunit.Removalandreplacementofthepowercordandplugwillvoidthewarranty.Forassistance,contactyourlocalauthorizedserviceagentforserviceorrequiredmaintenance.Attachthe4legsbyscrewingthemintotheweldnutslocatedonthebottomoftheunit.Whencomplete,usetwopeopletocarefullyturntheunitupright.Levelunitbyadjustingthefeet(approximately1/2"adjustment).Neveroperateunitwithoutproperlegsinplace.Before using the unit for the first time,wipedowntheexteriorwithadampcloth.
CAUTIONAllowenoughspacearoundtheovenforadequateventilation.Donotoperatetheunitwithoutthecrumbtrayproperlypositioned.Overheatingandpoorbakingmayoccur.Readalllabelsontheunitandfollowtheirinstructions.
LEG INSTALLATION
IL1035
CAUTION
CAUTION
CAUTION
�
ASSEMBLYANDINSTALLATIONcontinuedInstallunitinitsoperatingpositionallowsufficient space for operating personnel. InstalltheCrumb,LoadandUnloadTraysasshown,makingsuretheendsareatleast6"fromanyverticalcombustiblesurfaces.Haveanelectricianconnectinputpowertotheunit(s)inaccordancewithlocalelectricalcodes.Aconnectionterminalblockisinsidetheleftsidecavityformodelsnotprovidedwithacordandplugset.
ELECTRICALCONNECTIONBeforemakinganyelectricalconnectiontothisunit,checkthatthepowersupplyisadequateforthevoltage,amperageandrequirementsstatedontheratingplate.Awiringdiagramisincludedherewith.Disconnecttheunitfromthepowersourcebeforeinstallingorremovinganyparts.Beabsolutelysurethatthegroundconnectionforthereceptacleisproperlywired.Donotconnectequipmenttopowerwithoutpropergroundconnections.Impropergroundingmayresultinpersonalinjuryorfatality.
DONOTCUTORREMOVETHISPLUGORGROUNDINGPRONGFROMTHEPLUG.
CONNECT/PLUGUNITINTODEDICATEDA.C.LINEONLYSPECIFIEDONTHEDATAPLATEOFTHEUNIT.
HEATINGELEMENTSInspectallheatingelementsintheunitforbreakage.Everyunitisproperlytestedpriortoleavingthefactory,butdamagemayofoccurredduringshipping.Ifabrokentubeisfound,donotapplypowertotheunit.Ifeverythingchecksout,TurnonMainPowerSwitch,Turnbothheatcontrolsandconveyorbeltspeedcontroltothemaximumsettingandcheckallheatertubesandconveyorforproperoperation.
COOLINGSYSTEMAftertheunitisinitiallyturnedon,allow5to8minutesforthefancoolingsystemtocomeon.Onceon, check the air intake area located under the unit and be sure that there is a sufficient flow of air intothecontrolbox.Keepareaundertheunitcleanfromobstructionsthatmayresultinrestrictedairflow to the control box. Restricting the air flow will cause the unit to run hotter then designed, causing theHi-Limittoturnunitoff.SeetheOvenComponentssectiononpage7forcontrolbox&Hi-LimitResetlocations.
FINALCHECKIfallheatersandconveyorsystemsareoperatingproperly,switchthemasteron/offswitchtotheOFFpositionandallowunittocool,thefanwillcontinuetocirculateair,coolingtheunituntiltheinternaltemperatureshavebeendecreased.Ifaproblemisdiscoveredduringanyofthesestart-upprocedures,immediatelyswitchthemasteron/offswitchtotheOFFpositionandnotifytheStarServiceDepartmentat(314)634-6303.
CLEAN
OPERATE
UNLOADTRAY
EXTENDEDNOSEGUARD
CRUMB TRAY
TYPICAL LEFT TO RIGHT CONFIGURATION
ADJUSTABLE HEAT SHUTTERS
IL1038
WARNING
WARNING
6
STACKINGOVENSWhenstackingtwoHolmanMiniveyorOvensastackingspacerwithanexternalairductMUSTbeusedtopreventoverheatingofthecontrolboxofthetopoven.
1. Placebottomunitinpositionwheretheovenwillbelocated.2.Placestackingspacerontopofthebottomovenwithinternalairductfacingupand
towardstherearoftheoven.3. Mountexternalairductonstackingspacerasshownbelow.
Externalairductmustbeinstalledforcoolingsystemoftopunittofunctionproperly.4. Screwsetscrews(Qty4)intolegholeonthetopoven.5. Placetopovenonstackingspacer.Setscrewswillsetintocutoutintopofstacking
spacertolockunitintoposition.
NOTE: Air intake of top unit must fit over the internal air duct of stacking spacer to allow airflow into the control box of the top oven.
STACKING SPACER
SET SCREWS
TOP OVEN
BOTTOM OVEN
EXTERNAL AIR DUCT
IL1037
SET-SCREW CUT OUTS
TOPUNIT:setscrew,screwsintolegholes,unitsitsontopofspacer.STACKINGSPACER:(REQUIRED)Sitsontopofbottomoven.
EXTERNALAIRDUCT:Mountsontospacer,pointingdownward.
BOTTOMUNIT:Mustbeplacedonacounterinasecureposition.
7
DAILYOPERATIONBakingintheseunitsisacombinationofheatandbeltspeed.Somefoodsmayrequiremoretopheatorvisaversa;otherfoodsmayrequirelowtopandbottomheatandslowbeltspeeds.Everyproductshould,therefore,betestedusingtheseparatetop&bottomcontrolsandthevariablespeedcontroltoarriveatthecorrectbalanceofheatandbeltspeed.Whenchangingheatandorbeltspeedsettingallowapprox.5minutesfortheoventostabilizeitselfatthenewsettings.Checkthepowercordtoinsurethatitispluggedintoaproperoutlet.Alwaysallow10to15minutesofpreheattimebeforeloadingtheunitwithproduct.Failuretoallow sufficient preheat time will result in unsatisfactory cooking until the cooking chamber reaches operatingtemperature.Eventhoughtheelementscanreachthereoperatingtemperatureveryquickly,acertainamoutoftimeinneededtoallowthecookingchambertoreachitsoperatingtemperature.
1) Turnthemasteron/offswitchtotheONposition.2) Setboththetopandbottomheatcontrolsto500°F(260°C).3) Turnconveyorspeedcontroltothefastestsetting.4) Allow15-20minutesforinitialwarmup,
(5to8minutestoreachadjustedtemperature,onceunitisfullywarmedup)5) Oncetheunitispre-heated,adjustthecontrolstothepropersettingfortheproduct
youarepreparing.
CERTAINSURFACESAREEXTREMELYHOTDURINGOPERATIONANDCARESHOULDBETAKENWHILEUSINGTHISUNIT.OVENCOMPONENTS
UNLOAD TRAY
IL1039
ADJUSTABLE HEAT SHUTTER(QTY 2)
CONTROLBOX
HI-LIMITSWITCH
R TO L Conv.
POWERCORD
CRUMB TRAY
AIR INTAKEFAN
EXTENDED NOSE GUARD
ON/OFFSWITCH
UPPERHEAT
CONTROL
LOWERHEAT
CONTROL
CONVEYORSPEED
HI-LIMITSWITCH
L TO R Conv.
OPERATINGHINTSANDSAFETYDisconnectpowertotheunitwiththeswitchattheendofeachdayofoperation.Donotleavetheunitinoperationwithoutanattendant.Donotleavetheunitathightemperaturewhennotinuseorduringidleperiods.Thiswillcausefoodparticles and grease film to carbonize. Turning the temperature setting down will save energy, It will takeonlyafewminutesfortheunittoregainoperatingtemperature.
CAUTION
CAUTION
8
CLEANINGPreventivemaintenanceforyourHolmanOvenconsistsofthefollowingrecommendedcleaningprocedures.Tokeepyouroveninitstopoperatingcondition,thesestepsshouldbeperformedonadaily,weeklyorasindicated.
TURNUNITOFF,DISCONNECTUNITFROMPOWERSUPPLYORTURNPOWEROFFATWALLBREAKER,REMOVEPLUGFROMOUTLET.DAILY
1. TurnmainpowerswitchtotheOFFposition.Disconnectunitfrompowersourceandallowunittocool.
2. Usingamilddetergent,wipeexteriorsurfaces,cleanwithadampcloth.a.Forlightlysoiledbuild-up,cleanwithadampcloth.b.Forheavilysoiledbuild-up,useasoftdampclothandmilddetergent.DO NOT use caustic cleaners.
3. Removetheload&unloadtraybyliftingthemoutofposition.Cleanusingmilddetergentandwarmwater.
4. Remove each crumb tray by sliding each of them out from under the conveyor belt.C lean c rumb t rays by w ip ing w i th a damp c lo th and mi ld de tergent .DO NOT use caustic cleaners. Place trays back in place prior to putting unit back intooperation.
5. Reconnectpower.
WEEKLY1. Turnmainpowersaverswitchtothe
OFFposition.Disconnectunitfrompowersourceandallowtocool.
2. Performdailycleaningprocedures.3. Usingadampcloth,wipecleanthefan
guardlocatedonthecontrolboxcoverundertheunit.
CLEANCONVEYORBELT4. Reconnect power or turn power back
on.5. Switch the ON/OFF switch to the ON
position,andturnConveyortoitsfastestsetting.
6. WiththeConveyorturnedonandthecrumbtraysinplace,takeawiregrillbrushordryabrasivepad,cleantheexposedsurfaceofConveyorBeltbypassingthebrushorpad,backandforthacrossthesurfaceoftheConveyorBeltasthebeltmovespast.Continueuntiltheentirebeltisclean.MakesuretheCrumbTrayisinstalled,thiswillminimizetheamountofparticlesthatfallintotheoven.
7. WhentheConveyorBeltisclean,takeadampclothandwipetheconveyor,removing anylooseparticlesonthebeltsurface.
8. RemovetheCrumbTraysbyslidingoutfrombeneaththeconveyorbelt.CleantheCrumbTraysbywipingwithadampclothandmilddetergent.DONOTusecausticcleaners.
DONOTRUNCONVEYOROVENWITHOUTCRUMBTRAYSINSTALLED, OVERHEATINGTOELECTRICALCOMPONENTSANDPREMATUREFAILURECAN OCCURE.
DONOTIMMERSEORLETTHEUNITSTANDINWATER.
DONOTHOSEDOWNTHEUNITORTHETABLE/COUNTERIFTHEUNITISONTHETABLE/COUNTER.
KEEPAWAYFROMRUNNINGWATER.
WARNING
CAUTION
CAUTION
WARNING
IL1040
CLEANING CONVEYOR BELT
�
CLEANINGCONTINUED
MONTHLY1. TurnmainpowerswitchtotheOFFposition.Disconnectunitfromitspowersourceandallow
tocool.2. Performdaily&weeklycleaningprocedures.
REMOVAL&CLEANINGCONVEYORBELT3. Heavily soiledconveyorsurfaces,214models locateall 3of the
MasterLinkson theconveyorbelt.Follow thestep1 inFig1, toremovealloftheMasterLinks.
210modelshavenomasterlinks,toremove,unhookeachendofonelinkandbringthetwoendstogether,andunthread.Oncedetached,re-hookontoitselfsonottogetdamaged.
4. Nowthatthelinkshavebeenunhooked,theconveyorcannowbecarefullyremovedfromtheoven.Standingatoneendoftheoven.Startingwiththeendonthebottom,rolltheconveyorbeltuntilithasbeentotallyremoved.Takecarefulnoticebeingsurenottodamagetheheatertubes,andworkingitoverthedrivesprockets,(see Figure 2).
5. Clean conveyor belt in deep sink, caustic cleaners may be used.Foraheavysoiledconveyorbelt,soakovernightinhotsoapywater.
NOTE:DONOTATTEMPTTOCLEANTHEHEATERTUBES.6. Takethisopportunitytocleanandremoveanyloosematerialsinsidetheunit.Usinga
mildcleaneranddampcloth,carefullywipetheinsidesurfacesbeingsureNOTtocleantheheatertubes.DAMAGECANOCCURTOTHEHEATERTUBESFROMIMPROPERCLEANING.
DONOTSPRAYCLEANINGSOLUTIONSINTOOVENCAVITY.7. Reinstall conveyor belt by first laying the belt along the bottom of the oven cavity making sure
thehooksonthesidesarefacingtheinsideandtheendsofthehookswillbepointingawayformthedirectionofthebeltsonottocatchonanyinternalcomponentsonceputbackintooperation.Also,beingsuretoproperlyalignthebeltovertheConveyorDriveSprocketsshowninFig2.
NOTE:THEDIRECTIONOFTHEBELT.8. Next,pulloneendoftheconveyorbeltoverthetopofthe
sprockets,(beingsuretolinethelinksupproperlywiththesprockets)bringingthetwoendstogether.
9. 214models,Reinstallthepreviouslyremovedmasterlinksasshowninsteps2&3inFig.1.
210Models,unhookthelastlinkoftheconveyor,farthestawayfromyou,andrethreadthroughtheotherend,andreconnectbackontoitself.
12.Examinetheoventoassureproperinstallation,oncesatisfied, install crumb trays if you have not done so. DONOTOPERATEUNITWITHOUTCRUMBTRAYSINSTALLED.
13.Reconnectoventopowersupplyandcheckforproperoperation.
IFASSISTANCEISREQUIRED,CALLTHESTARSERVICETEAMAT(314)634-6303.
1.
2.
3.
IL1045
Fig1.MasterLinksRemoval&Installation
IL1046DRIVE SPROCKETS
Fig2.ConveyorDriveSprockets
CAUTION
CAUTION
�0
MAINTENANCEPROCEDURESA. REPLACINGHEATERTUBES 1) DISCONNECTPOWERSOURCE. 2) Removeboththeleftandrightsidepanels, byremovingthetrussheadscrews.Pullthe topofeachpaneloutslightlyandliftup. 3) Removeeachheatertubewireswhich arerequiringreplacementfromitsterminal blockconnection.OneTubeataTime. 4) Removeheatertuberetainerbyremoving retainerscrewswithwasher. 5) Gently,pulldefectiveheatertubeoutofunit. 6) Gently,putnewheatertubeintounit. 7) Replaceheatertuberetainers. 8) Reconnecttheheatertubewirestotheterminal
block. 9) Installeachsidepanel 10)Connectunittopowersourceandtestunitforproperoperation.
B. REPLACINGFANMOTOR1) DISCONNECTPOWERSOURCE.2) Afterunithascooled,removethecrumbtray,
andturnunitoversothebottomisfacingupward.Never place unit on its side.
3) Removethecontrolboxcoverwhichcontainsthefanmotor,byremovingthe2screws.
4) Unplugpowersupplycordfromfanmotor.5) Remove(4)screws,whichholdfanmotorandgrill
tothecontrolboxcoverandremovefan.6) Onceremoved,cleanfangrillandcontrolbox
coverusingwarmsoapywater.7) Putreplacementmotorandgrillinplaceand
securetothecontrolboxcoverwithscrewspreviouslyremoved.
8) Reconnectpowersupplycordtofanmotor.9) Replacebackpanelandenclosure.Fastenwith
screwsremovedinstep3.10) Connectunittopowersource,reinstallthecrumb
trayandtestunitforproperoperation.
C. REPLACINGBELTDRIVEMOTOR1) DISCONNECTPOWERSOURCE.2) Afterunithascooled,removethecrumbtray,
andturnunitoversothebottomisfacingupward.Never place unit on its side.
3) Removethecontrolboxcoverwhichcontainsthefanmotor,byremovingthe(2)screws.
4) Removethesidepanelthatwillexposethedrivechainandsprockets.
5) Removesprocketfrommotorshaft,usinganAllenwrenchandlooseningtheset-screw.
6) Removethewirefromterminalblockconnectingthedrivemotortotheinternalwiring.Onunitsrated208or240volts,notewhichcolorleadsarebeingusedfortheseconnectionsandwhichleadiscappedwithglasstape.Thenewmotorshouldusethesamearrangement.Referencethewiringdiagramifneeded.
7) Removescrewsholdingmotorinplaceandremovemotorfromunit.
8) Putnewmotorinplaceandattachlooselywithmountingscrews.9) Replacesprocketonmotorshaft.
NOTE: The two sprockets must line up FLUSH with each other, so the chain does not twist any during operation. Also the hub gets installed closets to the motor.
ELEMENT RETAINER
ELEMENT Control Side Shown IL1041
IL1042
FAN MOTOR
CONTROL BOX COVER
DRIVE MOTOR
DRIVE SPROCKET IL1043
��
MAINTENANCEPROCEDUREScontinued10) Slidemotoruntilthedrivechainhasabout1/4”slackwhen
lightlypushedatthecenterofitstopopenrun.See chain tensioning illustration.
11) Tightenscrewstosecuremotor.12) Rewireleadssameasremovedinstep6.13)Atthistimeyoumayplugunitinandtestforproperoperationprior
toreinstallingpanelsandturningunitbackoverontoitsfeet.14)Ifunitisworkingcorrectly,turnunitoffandunpluguntilcompleted.15) Reinstallsidepanelsandcontrolboxcover.
Placeunitbackintoitsuprightposition.Reinstallthecrumbtray.
16) Connectunittopowersourceandtestunitforproperoperation.
D. REPLACINGSPEEDCONTROL 1) DISCONNECTPOWERSOURCE.
2) Removethespeedcontrolknobandthelockingnutholdingthespeedcontrolinplace.
3) Removerightsidepanel,byremovingthetrussheadscrews.Pullthetopofthepaneloutslightlyandliftup.
4) Wiresfromthespeedcontrolgointoaterminalblocklocatedonthesideofthechassis.Removethewiresfromthecontrolandinsertwiresforthenewspeedcontrolintothesamepositionsasshownonthewiringdiagram.
5) Installthewasherontotheshaftofthespeedcontrol,followedbytheinstallation.
6) Whenmountingthespeedcontrolinthesidepanelbesuretopositiontheanti-rotationpinintheslotasshown.
7) Tightenthespeedcontrolassemblybyusingthelockingnut,followedbythecontrolknob.
8) Reinstallthesidepanelandtightenwiththescrewspreviouslyremoved.
E. CLEANINGAIRINTAKEONCEAWEEK. 1) DISCONNECTUNITFROMPOWERSOURCE. 2) Placeunitupsidedown. NOTE: You may damage the Heatertubes, by placing unit on its side. 3) Useavacuumcleanerandoradampclothtocleantheairintake. Thisprocedureshouldbedoneatleastonceaweek.
F. LUBRICATETHECHAIN&SPROCKETSEVERY6MONTHS 1) DISCONNECTUNITFROMPOWERSOURCE. 2) Removethesidepanelswhichexposeschaindrive. 3) Usinganextremepressure,syntheticchainlubricantwithatemperaturerangeupto400°F. Applyliberallyontochainandsprockets. Thisgreaseisavailableseparatelyaspartno.1P-Z8914.Call (314) 678-6303 to order. 4) Replacesidepanels,Reconnectpowersourceandtestunit.
IL1044
SPEED CONTROL WASHER
INSTALLATION
LOCKING NUT KNOB
SIDE PANEL
1/4”
Chain Tension
�2
TROUBLESHOOTINGGUIDEA. UNITWILLNOTHEAT,CONVEYORBELTWILLNOTMOVE. 1) BesurethemaincircuitbreakerisswitchedtotheONpositionandthereispowertotheoutlet. 2) ChecktoseeiftheovenispluggedinandallcontrolsareturnedtotheONposition. 3) BesuretheHi-LimitResetButtonispushedin. 4) CalltheStarServiceHelpDeskat(314)634-6303.
B. UNITWILLNOTHEAT,CONVEYORTURNSPROPERLY. 1) Checktoseeifthetopandbottomheatcontrolshavebeenturnedtothemaximumsetting. 2) PresstheHi-LimitResetButtonlocatedunderneaththeconveyorbeltontheinletside.Ifthisreactivates theheatertubes,seeHi-LimitResetSectionbelow. 3) Ifnot,calltheStarServiceHelpDeskat(314)634-6303.
C. HI-LIMIT(HEAT)RESET.YourHolmanconveyorovenisequippedwithanautomaticactivatedtemperaturelimitswitchwhichinterruptstheheatertubeconnectionsiftheairtemperatureinthecontrolboxexceeds190°F(88°C)Thislimitswitchcanberesetmanuallybypushingthebuttoninthecenteroftheswitchwhichislocatedonthepowercordsidepanel,onoldermodelsitsontherightsideundertheconveyorbelt.SeeOvenComponentsonPage7forlocation.Unitwillnotresetuntilinternaltemperaturehasfallenbelow190°F(88°C).
NOTE:THEHI-LIMITSWITCHCANBEACTIVATEDIFTHEREISNOTAPROPERAMOUNTOFAIRFLOWBEINGGENERATEDBYTHECOOLINGFAN.IFTHISOCCURS: 1) DISCONNECTUNITFROMPOWERSOURCE. 2) Checktoseeiftheairintakearea(centerofthecontrolbox,bottomofunit)isfreeofdust, greaseorotherobstructions. 3) Check to see if crumb trays (heat reflectors) are in place. If the Hi-Limit Switch can not be reset, call the StarServiceHelpDeskat(314)634-6303.
CAUTIONNEVEROPERATEUNITWITHOUTCRUMBTRAYSINPOSITIONASTHISCAUSESOVERHEATINGINTHECONTROLBOX.
D. CONVEYORWILLNOTTURN,UNITHEATSPROPERLY. Tocheckformechanicalbinding: 1) DISCONNECTUNITFROMPOWERSOURCE. 2) Checktoseeifthereareobstructionsintheconveyor systemthatmaycauseajam. Ifso,removeobstruction. 3) Checkpowersupply&terminalblocksforlooseor disconnectedwires.4) Removerightsidepanelanddrivemotorsprockets,
seeillustration.Manuallymoveconveyorbelttocheckformechanicalbinding.Ifconveyorbeltmovesfreely,calltheStarServiceHelpDeskat(314)634-6303.Thedrivemotororspeedcontrolmayhavetobereplaced.
E. CONVEYORTURNSATONESPEED REGARDLESSOFSPEEDCONTROLSETTING. 1) CalltheStarServiceHelpDeskat(314)634-6303,asspeedcontrolMAYneedreplacing. RefertoREPLACINGSPEEDCONTROLintheprevioussection.
F. COOLINGFANDOESNOTSTART 1) Removecontrolboxcoverandcheckfanbladeforobstruction. 2) Checkelectricalconnectionsaresecureandcomplete. 3) CalltheStarServiceHelpDeskat(314)634-6303,asthefanswitchandorfanmotorMAYneed replacing. RefertoREPLACINGFANMOTORintheprevioussection.
DRIVE SPROCKET CHAIN
IL1047
DRIVENSPROCKET
��
WIRINGDIAGRAMSAllwiringdiagramsonthefollowingpagesarethoseofcurrentandobsoletedesignmodels,andmaynotrepresentcurrentproduction.Todeterminewhichdiagramgoeswithyourunit,referencethenameplatelocatedonthecordsideoftheunit,andusethetablebelow.CalltheStarServiceHelpDeskat(314)634-6303,ifyouhavequestions,orunabletodetermineyourmodelsdiagram.
Temp Control
Phase Control
IL1048
Temperature Probe
Fan Switch
3 Wired Potentiometer 2 Wired Potentiometer
TEMP CONTROL PHASE CONTROL
Fan Switch
Pilot Light
HEATCONTROLSThereisonecontrolforeachheatcontrolknob.Thesearelocatedinthecontrolbox.Todeterminewhattypeofheatcontrolsyourunitisequippedwith,followtheseeasyinstructions.1. IfyourunitisequippedwithaPilotLightyourunit
isaTempControlunit,ifitdoesnothaveaPilotLight,youhaveaPhaseContolunit.
WIRINGDIAGRAMSTABLEOFCONTENTSDESCRIPTION PAGE210HX/214HX,120V,50/60Hz,4-Tube,WiredSeries 14210HX,120V,60Hz,4-Tube,WiredSeries,Canada 15210HX/214HX,208/220/240V,50/60Hz,3.2Kw,4-Tube,WiredSeries 15214HX,220V,50/60Hz,3.6Kw,4-Tube,WiredSeries 15214HX,208V,60Hz,4.0Kw,4-Tube,WiredSeries 15214HX,208V,60Hz,4.5Kw,4-Tube,WiredSeries 15210HX,120V,60Hz,4-Tube,WiredParallel 16214HX,240V,50Hz,4-Tube,WiredParallel 16214HXR,240V,50Hz,4.5Kw,4-Tube,WiredParallel 16214HX,208/240V,50/60Hz,3.6Kw,4-Tube,WiredParallel 16214HX,208/220/240V,50/60Hz,5-Tube,WiredParallel 17214HX,208/220/240V,50/60Hz,4.0Kw,5-Tube,WiredParallel 17214HX,208V,60Hz,4.5Kw,5-Tube,WiredParallel 17214HX,208/240V,60Hz,4.5Kw,6-Tube,WiredParallel 18210/214HX,208/240V,50Hz,CE,4-Tube,WiredSeries 19210/214HX,208/240V,50Hz,4-Tube,WiredParallel 20
�4
®
MODEL:210HX, 120V, 50/60Hz, 4-Tube, Wired Series 214HX, 120V, 60Hz, 4-Tube, Wired Series THIS DRAWING CONTAINS INFORMATION CONFIDENTIAL TO STAR MFG. INT'L. INC.NO REPRODUCTION OR DISCLOSURE OF ITS CONTENTS IS PERMITTED.
020022 Rev B 9/22/2009
GND
HEAT ADJUST
HEAT ADJUST
CONVEYORMOTOR
HIGHLIMIT
SWITCH
POWER ON/OFF
FAN CONTROL
FAN MOTOR
SPEED CONTROL
GND
L1
L2
AS SHOWN ABOVE FOR
CORD SUPPLIED UNITS
BLA
CK
WH
ITE
GROUND
L2 L1
Top Heat
Bottom Heat
BLU
YEL
ORG
ORG
BLU
BLK
BLK
RED
RED
YEL
RED
BLUBLK
PUR
BLK
WHT
RED
BLU
BLU
BLK
REDBLK
BLKBLK
��
RED
RED
YEL
ORG
BLU
BLU
YE
L
BLK
YE
L
BLK
WHT
PUR
BLK WHT
BLK
REDBLKRED
BLKBLKBLKBLU
RED
WHT
WHT
BLK
®
MODELS:210HX, 120V, 60Hz, 4-Tube, Wired Series, Canada210HX(P)/214HX, 208,220,240V, 50/60Hz, 3.2 Kw, 4-Tube, Wired Series214HX, 220V, 50/60Hz, 3.6 Kw, 4-Tube, Wired Series214HX, 208V, 60Hz, 4.0 Kw, 4-Tube, Wired Series214HX, 208V, 60Hz, 4.5 Kw, 4-Tube, Wired Series214HXBM, 240V, 60Hz, 4.5Kw, 4-Tube, Wired SeriesTHIS DRAWING CONTAINS INFORMATION CONFIDENTIAL TO STAR MFG. INT'L. INC.
NO REPRODUCTION OR DISCLOSURE OF ITS CONTENTS IS PERMITTED.
020001 Rev C 9/16/08
GND
HEAT ADJUST
HEAT ADJUST
CONVEYOR MOTOR
HIGHLIMITSWITCH
POWER ON/OFF
FAN CONTROL
FAN MOTOR
SPEED CONTROL
AS SHOWN ABOVE FOR
CORD SUPPLIED UNITS
BLA
CK
(brown*)
WH
ITE(blue*)
GROUND
L2 L1
*2E-Y9002 Shuko plug
�6
BLK
REDHIGH LIMIT
SWITCH
RED
RED
RED
GROUND
Top Heat
Bottom Heat
BLU
YEL HEAT
ADJUST
ORG
ORG
YEL
WHT
PUR
BLK
BLK
BLKBLKBLKBLU
WHT
WHT
BLK
®
MODEL:210HX, 120V, 60Hz, 4-Tube, Wired Parallel214HX, 240V, 50Hz, 4-Tube, Wired Parallel214HXR, 240V, 50Hz, 4.5Kw, 4-Tube, Wired Parallel214HX, 208/240V, 50/60Hz, 3.6Kw, 4-Tube, Wired Parallel
THIS DRAWING CONTAINS INFORMATION CONFIDENTIAL TO STAR MFG. INT'L. INC.
NO REPRODUCTION OR DISCLOSURE OF ITS CONTENTS IS PERMITTED.
020014 Rev A 11/17/2005
208/240 VAC
240 VAC
�7
�8
ORG
BLU
WHT
ORG
YEL
BLU BLU
RE
D
BLK
OR
G
BLK
BLK BLK
BLK
WHT
BRN
RE
D
RE
D
RE
D
BLK
YE
L
®MODEL:214HX, 208/240V, 60Hz, 4.5Kw, 6-Tube, Wired Parallel
THIS DRAWING CONTAINS INFORMATION CONFIDENTIAL TO STAR MFG. INT'L. INC. NO REPRODUCTION OR DISCLOSURE OF ITS CONTENTS IS PERMITTED.
020175 Rev - 9/11/2002
1
3 4
1
3 4
M
MDRIVE MOTOR
FAN MOTOR
ON/OFF SWITCH
RESET
SPEED CONTROL
BOTTOM HEAT
TOP HEAT
L1L2
GROUND
FAN SWITCH
HEAT ADJUST
ADJUSTHEAT
TOP HEAT
BOTTOM HEAT
��
PilotLight
Non-CordSupplied Units
L1
L2
GND
High-LimitSwitch
AS SHOWN ABOVE FOR CORD SUPPLIED UNITS
BLACK
WHITE
GROUND
L2
L1
TOP HEAT
FAN
BOTTOM HEAT
RED
RED
RE
D
ORN
WHT
BLK
BLK
WHT
YEL
BLK
BLK
BRN
BLKBLK
BLK
BLK
BLKBLK
REDRED
ORG
BLU
WH
T
OR
G
PU
R
OR
GY
EL
PU
R
YE
L
WH
T W
HT
WH
T
WH
T
OR
G
PU
R
OR
GY
EL
PU
R
YE
L
WH
T W
HT WHT
®
MODEL:210/214HX, 208/240V, 50Hz, CE, 4-Tube, Wired Series
THIS DRAWING CONTAINS INFORMATION CONFIDENTIAL TO STAR MFG. INT'L. INC. NO REPRODUCTION OR DISCLOSURE OF ITS CONTENTS IS PERMITTED.
820019 Rev. C 6/23/2006
20
®MODEL:210HX/214HX, 208/240V, 50Hz, 4-Tube, Wired Parallel
THIS DRAWING CONTAINS INFORMATION CONFIDENTIAL TO STAR MFG. INT'L. INC.
NO REPRODUCTION OR DISCLOSURE OF ITS CONTENTS IS PERMITTED.
820039 Rev - 2/07/2001
Top Heat
Bottom Heat
M
Main Power or Cordset
MConveyorMotor
PowerOn / Off
BOTTOM HEAT CONTROL
SpeedControl
High Limit Reset
BOTTOM TEMP. PROBE
FAN
TOP TEMP. PROBE
CONTROL
TOP HEAT
PILOT LIGHT
REDRED
BLK
BLK BLK
BLK
BLK
BLK
REDWHT WHT
ORG
BLU
BLKBLK
BLK
BLKBLK
BLK
BRN
REDRED
OR
GO
RG
YE
L P
UR
YE
L P
UR
WH
T
OR
G
YE
L P
UR
YE
L P
UR
OR
G
WH
T W
HT
WHT
WH
T W
HT
WH
T WHT
YEL
BLK
BLK
WHT WHT
YEL
2�
2M-4497-2 10/2010
The foregoing warranty is in lieu of any and all other warranties expressed or implied and constitutes the entire warranty.
FOR ASSISTANCE
Should you need any assistance regarding the Operation or Maintenance of any Star equipment; write, phone, fax or email our Service Department.In all correspondence mention the Model number and the Serial number of your unit, and the voltage or type of gas you are using.
ALL:* Pop-Up Toasters* Butter Dispensers* Pretzel Merchandisers
(Model 16PD-A Only)* Pastry Display Cabinets* Nacho Chip Merchandisers* Accessories of any kind* Sneeze Guards* Pizza Ovens (Model PO12 Only)* Heat Lamps* Pumps-Manual
Visit our Website at: www.star-mfg.com Email: [email protected]
THOROUGHLY INSPECT YOUR UNIT ON ARRIVALThis unit has been tested for proper operation before leaving our plant to insure delivery of your unit in perfect condition. However, there are instances in which the unit may be damaged in transit. In the event you discover any type of damage to your product upon receipt, you must immediately contact the transportation company who delivered the item to you and initiate your claim with same. If this procedure is not followed, it may affect the warranty status of the unit.
LIMITED EQUIPMENT WARRANTYAll workmanship and material in Star products have a one (1) year limited warranty on parts & labor in the United States and Canada. Such warranty is limited to the original purchaser only and shall be effective from the date the equipment is placed in service. Star's obligation under this warranty is limited to the repair of defects without charge, by the factory authorized service agency or one of its sub-agencies. Models that are considered portable (see below) should be taken to the closest Star service agency, transportation prepaid.
> Star will not assume any responsibility for loss of revenue.
> On all shipments outside the United States and Canada, see International Warranty.
* The warranty period for the JetStar six (6) ounce & Super JetStar eight (8) ounce series popcorn machines is two (2) years.
* ThewarrantyperiodfortheChrome-MaxGriddlesisfive(5)yearsonthegriddlesurface.Seedetailedwarrantyprovidedwithunit.
* ThewarrantyperiodforTeflon/Dura-Teccoatingsisoneyearundernormaluseandreasonablecare.ThiswarrantydoesnotapplyifdamageoccurstoTeflon/Dura-Teccoatingsfromimpropercleaning,maintenance,useofmetallicutensils,orabrasivecleaners,abrasivepads,productidentifiersandpoint-of-sale attachments, or any other non-food object tha comes in continuous contact with the roller coating. This warranty does not apply to the “non-stick” properties of such materials.
> This warranty does not apply to "Special Products" but to regular catalog items only. Star's warranty on "Special Products" is six (6) months on parts and ninety (90) days on labor.
> This warranty does not apply to any item that is disassembled or tampered with for any purpose other than repair by a Star Authorized Service Center or the Service Center's sub-agency.
> This warranty does not apply if damage occurs from improper installation, misuse, wrong voltage, wrong gas or operated contrary to the Installation and Operating instructions.
> This warranty is not valid on Conveyor Ovens unlessa"start-up/check-out"hasbeenperformedbyaFactoryAuthorizedTechnician.
PARTS WARRANTYParts that are sold to repair out of warranty equipment are warranted for ninety (90) days. The part only is warranted. Labor to replace the part is chargeable to the customer.
SERVICES NOT COVERED BY WARRANTY
PORTABLE EQUIPMENTStar will not honor service bills that include travel time and mileage charges for servicing any products considered "Portable" including items listed below. These products should be taken to the Service Agency for repair:
1. Traveltimeandmileagerenderedbeyondthe50mileradiuslimit 2. Mileage and travel time on portable equipment (see below) 3. Labor to replace such items that can be replaced easily during a daily cleaning
routine, ie; removable kettles on fryers, knobs, grease drawers on griddles, etc. 4. Installation of equipment5. Damagesduetoimproperinstallation 6. Damages from abuse or misuse 7. Operated contrary to the Operating and Installation Instructions 8. Cleaning of equipment 9. Seasoning of griddle plates
10. Voltage conversions11. Gas conversions12. Pilot light adjustment13. Miscellaneous adjustments14. Thermostat calibration and by-pass adjustment15. Resettingofcircuitbreakersorsafetycontrolsorresetbuttons16. Replacementofbulbs17. Replacementoffuses18. Repairofdamagecreatedduringtransit,delivery,& installationORcreatedbyactsofGod
* TheModel510FDFryer.* TheModel526TOAToasterOven.* TheModelJ4R,4oz.PopcornMachine.*TheModel518CMA&526CMACheeseMelter.* TheModel12MC&15MC&18MCPHotFoodMerchandisers.* TheModel12NCPW&15NCPWNachoChip/PopcornWarmer.* All Hot Dog Equipment except Roller Grills & Drawer Bun Warmers.* All Nacho Cheese Warmers except Model 11WLA Series Nacho Cheese Warmer. * All Condiment Dispensers except the Model HPD & SPD Series Dispenser.* AllSpecialtyFoodWarmersexcept Model 130R, 11RW Series, and 11WSA Series.* AllQCS/RCSSeriesToastersexcept Model QCS3 & RCS3 Series.* AllFastSteamerModelsexcept Direct Connect Series.
1
2
43
56
78
11
12
11 10
9
7
1314 15 16 17 18
19
20
22 21
24
2526
27
33
2829
30
32
34
35
36
38
37
11
1211
1039
4041
42
43
PhaseTemp
Nameplate
23
31
44
MODEL: MINIVEYOR210HX, 214HX SK2150 Rev. B 9/14/09
®
Fig No.
Part No Description
QuantityPer
1 GA-401287 1 TopCover2 HM-400891 2 HeatShutter3 2P-150001 1 DriveChain,12in.4 2P-Z8779 1 Sprocket,25P-11T5/16ID,Drive 2P-200646 1 Sprocket,25B20x5/16,Drive 210HXRC-V015 2P-200653 1 Sprocket,25B20x3/8,Driven 2P-115362 1 Sprocket,25B11x3/8,Driven 210HXRC-V016 2U-Z13803 1 DriveMotor,(L-R) 120V 2U-Z13804 1 DriveMotor,(R-L) 120V 2U-Z11871 1 DriveMotor,(R-L),CCW 208/240V 2U-Z11870 1 DriveMotor,(L-R),CW 208/220/240V7 HA-112261 2 Bearings8 2A-100906 1 DriveShaft9 GA-101401 1 UnloadTray10 2C-200015 8 Screws,8-32x3/8Knurled11 2P-200693 4 ExtensionBushing,Teflon12 2A-202904 2 IdlerShaft13 SEEELEMENTCHART 14 GA-402129 4 Retainers,HeaterTube(Quartz) GB-402444 6 Retainers,HeaterTube(Metal)15 SP-115341 1 HeatControlAssy.(Bot) 120V SP-115343 1 HeatControlAssy.(Bot) 2J-200567 1 HeatControlAssy.(Bot) CE16 SP-115340 1 HeatControlAssy.(Top) 120V SP-115342 1 HeatControlAssy.(Top) 2J-200567 1 HeatControlAssy.(Top) CE17 SP-118002 1 SpeedControl 120V GB-118062 1 SpeedControl18 2E-200180 3 Insulation,SwitchPot.19 GB-401328 1 SidePanel,(controls)20 2M-200818 1 ControlLabel21 SP-115360 3 KnobAssembly 2R-200708 3 Cap,Knob(includedin#21) 2R-200713 3 Skirt,Knob(includedin#21) 2R-200768 3 KnobControl(Includedin#21)22 SP-115338 2 Control,Phase 120V SP-115339 2 Control,Phase SP-115347 2 Control,Temp CEOnly23 2J-200568 2 HeatProbe CEOnly24 1P-E129912inchesEdging,16-18GA.SS(forbothholes)25 HG-402144 1 FanSwitchBracket26 2E-200574 1 FanSwitch
210HX Series Holman Conveyor Oven
Rev.J1/27/2012
27 2E-200543 1 On/OffSwitch28 2R-200716 4 Legs,2½”29 2P-401780 1 Guard,ToggleSwitch30 2J-200427 1 PilotLight CEOnly32 2U-200559 1 FanMotor 120V 2U-200561 1 FanMotor33 GA-401499 1 ControlBoxCover34 2R-200562 1 FanGrill35 2C-200048 4 Screw,FanGrill36 GA-401097 1 ExtendedNoseGuard37 HM-416962 1 CrumbTray38 GA-160001 1 ConveyorBelt,10”wide40 2E-200566 1 ResetSwitch41 GB-Z 1 SidePanel,L-R(cord)w/sideHi-Limit 12/3CordSet GB-Z10058-2 1 SidePanel,R-L(cord)w/sideHi-Limit 12/3CordSet GB-Z10055 1 SidePanel,L-R(cord)w/sideHi-Limit 14/3,16/3CordSet GB-Z10055-2 1 SidePanel,R-L(cord)w/sideHi-Limit 14/3,16/3CordSet GB-401524 1 SidePanel,(cord)w/osideHi-Limit GB-Z9862 1 SidePanel,(cord) HXETB42 2K-Y6764 1 Bushing,Cord12/3CordSet 2K-200463 1 Bushing,Cord14/3&16/3CordSet43 2E-200375 1 CordSet,14/3 120V 2E-200376 1 CordSet,14/3 208/240V 2E-Y9002 1 CordSet,16-3 CEApproved
NI 2C-200773 1 ButtonPlugNI 2E-200387 1 Cord,CoolingFanNI 2P-115501 AR Jumpers(2Position)NI 2P-115502 AR Jumpers(3Position)NI GE-115503 AR Jumpers(4Position)NI HA-115383 AR Block,Terminal(3Position)NI HC-115381 AR Block,Terminal(4Position)NI HK-115388 AR Block,Terminal(6Position)NI HB-115387 AR Block,Terminal(8Position)NI HC-115390 AR Block,Terminal(10Position)
NI 1L-Z12397 1 EXTREMEPRESSUREMULTIPURPOSESYNTHETIC GREASE(80°FTO400°F),TUBE1oz.
NI=NOTILLUSTRATED,AR=ASREQUIRED
Fig No.
Part No Description
QuantityPer
Fig No.
Part No. Description
QuantityPer
1 GB-401288 1 TopCover2 HM-400899 2 HeatShutter3 2P-150001 1 DriveChain,12in.4 2P-200643 1 DriveSprocket 2P-200646 1 DriveSprocket(20tooth) 214HXRC,HXETB,HXR 2P-200653 1 DriveSprocket(20tooth)214HXRRCM,214HXRCM5 2P-200653 1 DrivenSprocket 2P-115362 1 DrivenSprocket(11tooth) 214HXRC,HXETB,HXR 2P-Z8779 1 DrivenSprocket(11tooth)214HXRRCM,214HXRCM6 2U-Z11871 1 DriveMotor,(R-L),CCW 214HXR 2U-Z11870 1 DriveMotor,(L-R),CW 214HXR,214HXRRCM, 214HXRCM7 GB-112262 2 Bearings8 2A-100907 1 DriveShaft9 GB-101402 1 UnloadTray10 2C-200015 8 Screws,8-32x3/8Knurled11 2P-200693 4 ExtensionBushing12 2A-202905 2 IdlerShaft13 SEE ELEMENT CHART 14 GB-402245 6 Retainers,QuartzElements GB-402444 6 Retainers,MetalElements GA-402129 4 Retainer,QuartzElements CEOnly GB-Z9864 1 Retainer,6MetalElements HXETB,HXRETB15 SP-115341 1 HeatControlAssy.(Bottom) 120V SP-115343 1 HeatControlAssy.(Bottom) 208/220/240V 2J-200567 1 HeatControlAssy.(Bottom)TEMP CEOnly16 SP-115340 1 HeatControlAssy.(Top) 120V SP-115342 1 HeatControlAssy.(Top) 208/220/240V 2J-200567 1 HeatControlAssy.(Top)TEMP CEOnly17 GB-118062 1 SpeedControl18 2E-200180 3 Insulation,SwitchPot.19 GB-401328 1 SidePnl,(controls)19 GB-Z9861 1 SidePnl,(controls)mfgbefore11/07HXETB,HXRETB20 2M-200818 1 ControlLabel 2M-200819 1 ControlLabel 214HXALT 2M-Z9876 1 ControlLabel 214HXRC,HXETB,HXR21 SP-115360 3 KnobAssembly 2R-200708 3 Cap,Knob(includedin#21) 2R-200713 3 Skirt,Knob(includedin#21) 2R-200768 3 KnobControl(Includedin#21)22 SP-115339 2 Control,Phase SP-115347 2 Control,Temp CEOnly23 2J-200568 2 HeatProbe CEOnly
214HX Series Holman Conveyor Oven
Rev.J1/27/2012
24 1P-E1299 12in Edging,16-18GA.SS(forbothholes)25 HG-402144 1 FanSwitchBracket26 2E-200574 1 FanSwitch27 2E-200543 1 On/OffSwitch28 2R-200716 4 Legs,2½”29 2P-401780 1 Guard,ToggleSwitch30 2J-200427 1 PilotLight, CEOnly31 2E-200535 1 Contactor;Relay32 2U-200561 1 Motor,Fan240V23BTM32 2U-200559 1 Motor,Fan120V12A12-BTM 120V33 HM-401498 1 ControlBoxCover34 2R-200562 1 FanGrill35 2C-200048 4 Screw,FanGrill36 HM-401096 1 ExtendedNoseGuard37 HM-402787 1 CrumbTray38 GB-160007 1 ConveyorBelt,14”Wide39 2B-200603 3 MasterLinks 214HX40 2E-200566 1 ResetSwitch41 GB-Z10058 1 SidePnl,L-R(cord)w/sideHi-Limit 12/3CordSet GB-Z10058-2 1 SidePnl,R-L(cord)w/sideHi-Limit 12/3CordSet GB-Z10055 1 SidePnl,L-R(cord)w/sideHi-Limit 14/3,16/3CordSet GB-Z10055-2 1 SidePnl,R-L(cord)w/sideHi-Limit 14/3,16/3CordSet GB-401524 1 SidePnl,(cord)w/osideHi-Limit GB-Z9862 1 SidePnl,(cord) HXETB,HXRETB42 2K-Y6764 1 Bushing,Cord12/3CordSet 2K-200463 1 Bushing,Cord14/3&16/3CordSet43 2E-200375 1 CordSet,14/3 120V 2E-200376 1 CordSet,14/3 208/220/240V 2E-200374 1 CordSet,12/3 208/220/240V 2E-Y9002 1 CordSet,16/3 220/240VCEApproved HG-Z16423 1 CordSet,BS546 214HXA-V2844 2E-30901-08 2 FuseHldrforSCFuse 2E-Z5680 2 FUISE-CLASSG(5amp)NI 2E-200387 1 Cord,CoolingFanNI 2P-115501 AR Jumpers(2Position)NI 2P-115502 AR Jumpers(3Position)NI GE-115503 AR Jumpers(4Position)NI HA-115383 AR Block,Terminal(3Position)NI HC-115381 AR Block,Terminal(4Position)NI HK-115388 AR Block,Terminal(6Position)NI HB-115387 AR Block,Terminal(8Position)NI 1L-Z12397 1 MultipurposeSyntheticGrease(80°FTO400°F),tube1oz.
Fig No.
Part No. Description
QuantityPer
NI=NOTILLUSTRATED,AR=ASREQUIRED
Fig No.
Part Number Description
QuantityPer
210HX 13 GA-199100 4 Heater Tube (430W, 3.58A) 120V (Metal) 14.3 GH-197848 4 HeaterTube(7.86Ω,425W,3.54A) 120V(Quartz) 14.2 2N-209197 4 Heater Tube (700W, 3.36A) 208V (Metal) 13.4 HO-197841 4 HeaterTube(14.5Ω,700W,3.36A) 208V(Quartz) 13.4 HT-197845 4 HeaterTube(800W,3.84A) 208V(Quartz) 15.4 HO-197844 4 HeaterTube(15.84Ω,700W,3.18A) 220V(Quartz) 12.7 HT-197846 4 HeaterTube(800W,3.63A) 220V(Quartz) 14.5 HO-199106 4 Heater Tube (700W, 2.91A) 240V (Metal) 11.6 HO-197842 4 HeaterTube(19.2Ω,700W,2.91A) 240V(Quartz) 11.6 HT-187847 4 HeaterTube(800W,3.33A) 240V(Quartz) 13.3
214HX 13 GC-197855 4 HeaterTube(16.66Ω,432W,3.6A) 120V(Quartz) 14.4 2N-Z11215* 5 HeaterTube(51.02Ω,800W,3.85A) 208V(MetalExtended)HXETB&HXRETB 19.2 2N-209130 5 HeaterTube(51.02Ω,800W,3.85A) 208V(Metal) 19.3 2N-209130 6 HeaterTube(51.02Ω,800W,3.85A) 208V(Metal) 23.1 HT-197851 3 HeaterTube(59.0Ω,909W,4.37A) 208V(Quartz) 13.1 HT-197845 4 HeaterTube(104V,810W,3.89A)Series 208V(Quartz) 31.1 HT-197851 4 HeaterTube(59.0Ω,909W,4.37A) 208V(Quartz) 17.5 GB-197900 5 HeaterTube(50.8Ω,800W,3.86A) 208V(Quartz) 19.3 HT-197851 5 HeaterTube(59.0Ω,909W,4.37A) 208V(Quartz) 21.9 HT-197846 4 HeaterTube(110V,850W,3.86A)Series 220V(Quartz) 30.9 GB-198037 5 HeaterTube(56.8Ω,800W,3.65A) 220V(Quartz) 18.3 2N-Z11216* 5 HeaterTube(68Ω,800W,3.33A) 240V(MetalExtended)HXETB&HXRETB 16.7 2N-209160 5 HeaterTube(68Ω,800W,3.33A) 240V(Metal) 16.6 GB-199160 5 HeaterTube(68Ω,800W,3.33A) 240V(Metal) 16.7 HT-197850 3 HeaterTube(59.0Ω,921W,3.84A) 240V(Quartz) 11.5 HT-197850 4 HeaterTube(59.0Ω,921W,3.84A) 240V(Quartz) 15.4 GB-197847 4 HeaterTube(120V,810W,6.75A)Series 240V(Quartz) 27 HT-197852 4 HeaterTube(13.49Ω,1000W,4.16A) 240V(Quarts)CE 16.6 HT-197850 5 HeaterTube(59.0Ω,921W,3.84A) 240V(Quartz) 19.2 HX-197895 5 HeaterTube(66.5Ω,815W,3.4A) 240V(Quartz) 15.6
*=NotinterchangeableonHXTBunits
210HX&214HXSeriesElementChart
Rev.J1/27/2012
Unit Voltage/Type Units Amp