LocalorNetworkAttached Sensors LocalorNetworkAttached Actuators/ControlDevices 1Year+LocalData, UnlimitedNetworkStorage ViewLocalorNetwork Data LAN*/RS485/ OpticLAN Series Models ProofLoad Material Output Accuracy InsulationInsulation ExplosionProof Graphic/English-Spanish-Chinese RealTime/Archive /DataSynchronizedReplay Berths/Vessels/MooringPatterns /System /Users LAN*/GSM-GPRS/ GPRS/RF/ RS232/RS485 Indoor

TRANSCRIPT

Series

Models

Proof Load

Material

Output

Accuracy

InsulationInsulation

Explosion Proof

Local or Network Attached Sensors

Local or Network Attached Actuators / Control Devices

1 Year+ Local Data, Unlimited Network Storage

View Local or Network Data

LAN* / RS485 / Optic LAN

2 x 3 Digits LED, 64 Characters LCD, 15 Indicators

26 Keys

24 Analog or Digital / Expandable

24 Analog or Digital / Expandable

IP56* / IP66 / EXD

Graphic / English-Spanish-Chinese

Real Time / Archive / Data Synchronized Replay

Berths /Vessels /Mooring Patterns / System / Users

LAN* / GSM-GPRS / GPRS / RF / RS232 / RS485

Indoor

Industrial Workstation, Quad Core 2GHz+ / 1TB+

MMCS-CS Suite with Industrial Database, Multi Platform

MMCS-CS-MLM Mooring Load Monitoring Suite

Up to 24 Berth

Real Time / Time Span / Voyage / Alarm / Replay

■ All MMCS stations are expandable. All MMCS application systems are expandable. Other components, such as sensors / control devices, Handheld Stations, Large Display Monitoring Stations, etc., can also be added to any MMCS platform system. All MMCS application systems can be seemless integrated. See other MMCS documentations for more information■ Some functions require purchase of relevant options■ All specs are subject to revision without notice. Please contact us to verify prior to ordering

■ 30998 Huntwood Ave., Suite 109, Hayward. CA 94544, USA ■ Tel. 510 487 2289 Fax. 510 487 2586 ■ www.zaldatechnology.com ■

DS1 Laser Distance Sensor

100m / 200m / 300m / 500m Models ( DS1-XXX)

Class 1

RS232* / RS485

5cm

IP67

Intrinsically SafeIntrinsically Safe

Optional / 2D or 3D / Numeric Controlled with Feedbacks

Optional On-Off Control / Data Frequency Control / Automatic Anti Condensation Space Heater

Local or Network Attached Sensors

Local or Network Attached Actuators / Control Devices

1 Year+ Local Data, Unlimited Network Storage

View Local or Network Data

LAN* / RS485 / Optic LAN

2 x 3 Digits LED, 64 Characters LCD, 15 Indicators

26 Keys

24 Analog or Digital / Expandable

24 Analog or Digital / Expandable

IP56* / IP66 / EXD

Graphic / English-Spanish-Chinese

Real Time / Archive / Data Synchronized Replay

Berths /Vessels /Mooring Patterns / System / Users

LAN* / GSM-GPRS / GPRS / RF / RS232 / RS485

Indoor

Industrial Workstation, Quad Core 2GHz+ / 1TB+

MMCS-CS Suite with Industrial Database, Multi Platform

MMCS-CS-BSM Berthing Status Monitoring Software

Up to 24 Berth

Real Time / Time Span / Voyage / Alarm / Replay

■ All MMCS stations are expandable. All MMCS application systems are expandable. Other components, such as sensors / control devices, Handheld Stations, Large Display Monitoring Stations, etc., can also be added to any MMCS platform system. All MMCS application systems can be seemless integrated. See other MMCS documentations for more information■ Some functions require purchase of relevant options■ All specs are subject to revision without notice. Please contact us to verify prior to ordering

■ 30998 Huntwood Ave., Suite 109, Hayward. CA 94544, USA ■ Tel. 510 487 2289 Fax. 510 487 2586 ■ www.zaldatechnology.com ■

Local or Remote MMCS Sensors

Local or Remote MMCS Actuators / Control Devices

1 Year + Local Data,

View Local or Remote MMCS Data

LAN* / RS485 / Optic LAN

2 x 3 Digits LED, 64 Characters LCD, 15 Indicators

26 Keys

24 Analog or Digital / Expandable

24 Analog or Digital

IP56* / IP66 / EXD

Graphic / English*-Spanish-Chinese

Optional, with Synchronized Archive-Replay

Interface - Integration / System / Users

LAN* / GSM-GPRS / GPRS / RF / RS232 / RS485

Indoor

Industrial Workstation, Quad Core, 1TB+

MMCS-CS with Industrial Database, Multi Platform

MMCS-CS-MEM /ACM ( Crane-Scanner Control )

Up to 24 Berth

Real time / Time Span / Voyage / Alarm / Replay

■ Other MMCS components such as Handheld Stations and Large Display Monitoring Systems, can also be added to a MMCS platform system■ All MMCS stations are expandable. Some functions require purchase of relevant options■ See other MMCS documentations for more information■ All specs are subject to revision without notice. Please contact us to verify prior to ordering

■ 30998 Huntwood Ave., Suite 109, Hayward. CA 94544, USA ■ Tel. 510 487 2289 Fax. 510 487 2586 ■ www.zaldatechnology.com ■

Local or Remote MMCS Sensors

Local or Remote MMCS Actuators / Control Devices

1 Year + Local Data,

View Local or Remote MMCS Data

LAN* / RS485 / Optic LAN

2 x 3 Digits LED, 64 Characters LCD, 15 Indicators

26 Keys

24 Analog or Digital / Expandable

24 Analog or Digital

IP56* / IP66 / EXD

Graphic / English*-Spanish-Chinese

Optional, with Synchronized Archive-Replay

Interface - Integration / System / Users

LAN* / GSM-GPRS / GPRS / RF / RS232 / RS485

Indoor

Industrial Workstation, Quad Core, 1TB+

MMCS-CS with Industrial Database, Multi Platform

MMCS-CS-ACM

Up to 24 Berth

Time Span / Voyage / Alarm / Replay

■ Other MMCS components such as Handheld Stations and Large Display Monitoring Systems, can also be added to a MMCS platform system■ All MMCS stations are expandable. Some functions require purchase of relevant options■ See other MMCS documentations for more information■ All specs are subject to revision without notice. Please contact us to verify prior to ordering

■ 30998 Huntwood Ave., Suite 109, Hayward. CA 94544, USA ■ Tel. 510 487 2289 Fax. 510 487 2586 ■ www.zaldatechnology.com ■

30998 Huntwood Ave., Suite 109, Hayward. CA 94544, USA Tel. 510 487 2289 Fax. 510 487 2586 www.zaldatechnology.com

MMCS Marine Application Systems

As one of world leading harbor berthing – mooring solution provider, Zalda Technology offer several berthing and mooring related

application systems based on our powerful MMCS monitoring and control platform:

Zalda Technology Mooring Load Monitoring System ( MMCS-MLM )

Enhance mooring safety by providing real time, historical, and analyzed ship mooring load information on multiple berths via

MMCS station network and other common types of computer network platforms. Building blocks of the MMCS-MLM network

system are Zalda LS series load sensor, Z series quick release hooks, MMCS LIS / CS / HMS / DCS / DES stations and other

compatible commercial network computer devices.

Zalda Technology Berthing Status Monitoring System ( MMCS-BSM )

Minimize ship berthing and drifting accidents by providing real time, historical, and analyzed ship distance / speed / angle /

tendency information on multiple berths via MMCS station network and other common types of computer network platforms.

Building blocks of the MMCS-BSM network system are Zalda DS series load sensor with or without Numeric Controlled Scanner

Base, MMCS LIS / CS / HMS / DCS / DES stations and other compatible commercial network computer devices.

Zalda Technology Marine Environment Monitoring System ( MMCS-MEM )

Provide real time, historical and analyzed information on harbor marine and atmospheric environment factors, such as :

-- Current / Wave / Tide

-- Wind / Temperature / Humidity / Barometric Pressure / Visibility / Dangerous Gas Air Content

via MMCS station network and other common types of computer network platforms. Building blocks of the MMCS-MEM network

system are Zalda MMCE-MEM series environment sensors, MMCS LIS / CS / HMS / DCS / DES and other compatible commercial

network computer devices.

Zalda Technology Mooring Line Release Automation and Management ( MMCS-ACM )

Quickly and safely release ship mooring cables attached to mooring hooks and monitor release status before and after the release

commands on multiple berths via MMCS station network and other common types of computer network platforms. Building blocks

of the MMCS-MLM network system are Zalda EA / HA series actuators, proximity switches, Z series quick release hooks, MMCS

LIS / CS / HMS / DCS / DES and other compatible commercial computer devices.

Refer to Zalda Technology application systems literature for more information on each application system. Contact Zalda for other

applications based on MMCS platform, such as Network Power Control and Management ( MMCS-SUPS ), Crane-Davit

Automation and Management ( MMCS-CDAM ), and General Purpose Random Programmed Control Automation ( MMCS-RPA ).

30998 Huntwood Ave., Suite 109, Hayward. CA 94544, USA Tel. 510 487 2289 Fax. 510 487 2586 www.zaldatechnology.com

COMMON HIGHLIGHTS OF ALL MMCS BASED APPLICATION SYSTEMS:

Any single purpose system based on MMCS platform can be easily expanded into simultaneous “multi berth”, “multi channel”,

“multi media”, “multi purpose”, ”multi application” marine monitoring & control system. Modular design allows any MMCS

based system to adapt to new application, or new requirements of existing application at minimum cost and effort.

“Multi purpose” and “multi application” means every interactive station / device allowed into the system, such a Zalda LIS

Local Interface Station, a HMS-HCS Handheld Station or the cell phone of an authorized operator, can monitor and control

across several application systems integrated on the same platform. For example, on the same local interface station, an

user can control release actuators, davits, AV alarms, or winches, while monitoring mooring load, berthing status, or current

speed at the same time; the same tasks can also be performed on his Black Berry. To an MMCS user, every device he has

access to can be his central control room.

“Multi channel” means most monitoring and control functions of a MMCS based system can be performed on a MMCS

station, or an authorized computing device via commercial networks such as LAN / WIFI / WWW / GPRS / GSM / SMS /

Edge / RF without sacrificing safety standard. AV alarms and large display panels under MMCS control are also supported

as additional channels of information access.

“Multimedia” stands for audio interface / signals, visual interfaces / signals, and surveillance video on MMCS platform

interfaces. This makes easier for MMCS system personnel to interpret incoming information and make decisions accordingly.

Interactive network monitoring & control, real time automation programming, network power on-off control, surveillance video

integration, audio assisted monitoring, and configurable mobile device platform are some of the “first of its kind” advance

functions amongst it peers.

Developed for marine robot applications, MMCS is a highly sophisticated general industrial monitoring and control platform

that can easily adapt to most other marine or general industrial monitoring and control - automation applications. If required,

Zalda can customize at component or system level to meet application requirements or customer preferences MMCS CORE COMPONENTS AND FEATURES FOR ALL MMCS BASED APPLICATION SYSTEMS:

Local Interface Station ( MMCS-LIS), a stand alone programmable, modular MCU based, local monitoring – control - storage

device with network capability to simultaneously support a variety of monitoring and control applications

Data acquisition and monitoring of different types of locally attached digital or analog sensor readings at 24 standard

quantity, or expandable quantities at folds of of 24 with each additional IO expansion module.

Controls different types of locally attached on-off or pulse control devices at 24 standard quantity, or expandable

quantities at folds of 24 with each additional IO expansion module.

Record local data on expandable storage modules or mass storage devices.

Access real time sensor readings, control functions, historical and analyzed data stored on storage module with LED-LCD

dual display and 26 key keyboard

Current software supports load / weight monitoring, distance / linear displacement / speed / angle monitoring, switch on /

off monitoring, environmental sensor readings, real time / peak / average monitoring, data search, fixed course motion

control, random direction motion control, programmable motion control, synchronization & constant tension based

automation, programmable monitoring and control alarms, AV alarm-light control, setup and programming utility, etc..

Unified user interface for all type of monitoring and control functions.

From each Local Interface Station, access control functions, monitoring functions, and stored data on all remote Local

Interface Stations within the same system via network and serve as a central monitoring and control system of the entire

MMCS system.

Special MMCS protocol for added safety

30998 Huntwood Ave., Suite 109, Hayward. CA 94544, USA Tel. 510 487 2289 Fax. 510 487 2586 www.zaldatechnology.com

Central Station ( MMCS-CS), an advanced monitoring & control server with advanced graphic interface, database and

network capability

Supports all monitoring or control functions of Local Interface Stations, with a more advanced graphic user interface,

database & utilities.

LAN / WIFI / WWW / GPRS / GSM / SMS / Edge / RF / LDMS extensions eliminate extend the MMCS for infinite

accessibility. Easily specify, format, and revise the content to be published on each extension from an unified interface;

from the same interface, set up the who, when, how of user remote access and what is allowed to monitor or control after

access is granted.

Sensor & control map layout view on the CS interface, is where the monitoring sensors and device control access points

are placed as indicator icons in a map layout similar to the actual geographic layout of the system jobsite. An user who is

familiar to the layout of his jobsite, can easily understand the status of entire system with a glimpse of the appearance of

various interface icons. It also easy to him to locate and acquire more details on any specific sensor by clicking on the

relevant indicator icon; by clicking on any control device icon an user can open up the relevant control interface and

quickly specify control commands.

Replay data on interface, analyze data and generate report are some of the standard functions of the MMCS database.

Simply specify criterions, customize interface and customize output layout and format, the data replay or report will be

ready for your preview before output into specified format.

Berth / jobsite navigation views allow users to jump from one berth / site to another, or set up the appearance of his

various berths / site according to preference, if his system covers several berths or sites.

Setup alarm coordinates and actions easily from a unified alarm setup interface. When alarm is triggered, AV alarms and

reports of the Central Station distinguish different alarms by message content, color, and sound for instant identification.

External AV alarm can also be attached to CS.

User setup, equipment setup are provided as standard CS base utility; Berthing – mooring related design tools are

provided as part of the berthing – mooring application software.

Special MMCS protocol for added safety

Handheld Station ( MMCS-HMS / MMCS-HCS), an industrial grade handheld computer with wireless network capability and

special interface for accessing the monitoring and control function

GPRS / GSM / SMS / Edge / RF/ WIFI wireless communication with different range / data transmission rate limitation

IP / EXD / ATEX ratings

Sensor & control map layout view similar to the one on the CS interface with similar monitoring and control operation

when applicable

Special MMCS protocol for added safety