121
FeaturesCommon Features of the T9000 Products•Fullyfunctionalkeypadanddisplay.•BacklitLiquidCrystaldisplayscreen.•Output pressure displays in psig, BAR, kPa,oruser-definedpressureunits.•Independently adjustable PIDtuning coefficients.•Reverse acting capability for analog input andoutputsignals.•Select Current or Voltage mode for input signal or optional analog channels using thekeypad.•RFI/EMIprotectioneliminates electromagneticandradiointerference.
Operating PrinciplesThe Model T9000 Ser ies PressureControllers have a closed-loop, integrated,microprocessorcontrolsystemthatregulatesoutlet pressure. You can control the outputfrom the Model T9000 products using thekeypad or from an analog control signal.You can control the output from theModelT9000D using the keypad and throughDeviceNetTMCommunicationnetwork.
The Feed and Bleed Solenoid Valvescontrol pressure in the Signal Chamberof the Booster Section. A pressure sensormeasures the outlet pressure and providesafeedbacksignaltotheElectronicsSection.Any variation in pressure between thesetpoint and the outlet pressure activatesthe Feed and Bleed Solenoid Valves tocorrecttheoutputpressure.
BModel T9000
800-334-8422www.fairchildproducts.com
T9000
T9020
T9060
T9080
T9040
T9010
BModel T9000
122 800-334-8422www.fairchildproducts.com
T9000
0
30
60
90
120
150
-20 0 20 40 60 80 100 120 140
Supply Pressure = 150 PSIG
Setpoint = 30 PSIG
Setpoint = 60 PSIG
Setpoint = 90 PSIG
Setpoint = 120 PSIG
Air Flow, SCFM
Outpu
t Pres
sure,
PSIG
Flow CharacteristicsT9040-4074N4FJT Pressure Controller
T9010
Model T9000 Electro-Pneumatic Transducer
T9020 SeeT9000ForTopView
0
30
60
90
120
150
-10 0 10 20 30 40 50 60 70 80 90 100
Supply Pressure = 150 PSIG
Setpoint = 30 PSIG
Setpoint = 60 PSIG
Setpoint = 90 PSIG
Setpoint = 120 PSIG
Air Flow, SCFM
Outpu
t Pres
sure, P
SIG
Flow CharacteristicsT9020-4072N4NFS Pressure Controller
T9040 SeeT9000ForTopView
T9060 T9080
123 800-334-8422www.fairchildproducts.com
Model T9000 Electro-Pneumatic Transducer
0
30
60
90
120
150
0 50 100 150 200 250
Supply Pressure = 150 PSIG
Setpoint = 30 PSIG
Setpoint = 60 PSIG
Setpoint = 90 PSIG
Setpoint = 120 PSIG
Air Flow, SCFM
Out
put P
ress
ure,
PSI
G
Flow CharacteristicsT9060-4074N4FNT Pressure Controller
Model T9000
FlowCharacteristicsChart Foward Exhaust150psig[10BAR]Supply60psig[4BAR]DownstreamPressure
T9000T9010 T9020 T9040 T9060T9080
1SCFM12SCFM90SCFM110SCFM220SCFM700SCFM
-4SCFM45SCFM55SCFM110SCFM350SCFM
Model T9000 Electro-Pneumatic Transducer
124
InstallationFor operating instructions, refer to the corresponding FairchildOperation and Maintenance Instructions, OM-500T90FI,OM-500T90AB,OM-500T90AO,OM-500T90DB,OM-500T90DI,OM-500T90DO.
Forinstallationinstructions,refertoII-500T9000.
Catalog InformationSpecificationsSupply Pressure1200psig,[14BAR],(1400kPa)MaximumPneumatic Outputs psig: 0-30 0-75 0-150 [BAR]: [0-2] [0-5] [ 0 - 1 0 ] (kPa): (0-200) (0-500) (0-1000) Minimum Span psig: 12 30 6 0 [BAR]: [0.8] [2.0] [ 4 . 0 ] (kPa): (80) (200) (400)
Input Signal4-20mA,0-10VDCFlow Rate1-700SCFM(Selectdesiredconfiguration)Exhaust Flow 1-350SCFM(Selectdesiredconfiguration)
Air Consumption 0@steadystateoutputwithDeadband@1%ofFullScale Supply Pressure EffectNoMeasurableEffectElectrical Supply24VDC±10%Power ConsumptionLessthan5wattsAnalog Output Signal / Impedence4-20mA/500ohmsMaximum,0-10VDC/400ohmsMinimumDeadband (ISA S51.1)Adjustablefrom0to10%ofFullScaleUnit Accuracy (ISA S51.1)Lessthan0.50%OutputSpanFrequency [email protected](typicalbutdependsonspecificT9000productconfiguration)Vibration EffectLessthan1%ofSpanunderthefollowingconditions:[email protected]@10g’sRFI/EMI EffectLess than 0.5%. EMC Directive 89/336/EEC EuropeanNormsEN50081-2&EN50082-2.Temperature Range0°Fto+160°F,(-18°Cto+71°C)Materials of Construction BodyHousing........Polymer,ChromateTreatedAluminumTrim........................................................ ZincPlatedSteelElastomers......................................... Nitrile,FluorocarbonFinish........................................................................Epoxy1 Supply Pressure must be no less than 5 psig, [0.35 BAR], (35 kPa) above
maximum output.
800-334-8422www.fairchildproducts.com
BModel T9000
Catalog Number T90
Flow Rate1 SCFM (Basic Transducer) ....... 0012 SCFM ……………………......... 1090 SCFM ……………………......... 20110 SCFM …………………......... 40220 SCFM……………………........ 60700 SCFM ……………………....... 80
Input0-10 VDC . . . . . . . . . . . . . . . . . . . . . . . 04-20 mA . . . . . . . . . . . . . . . . . . . . . . . . 4DeviceNet TM. . . . . . . . . . . . . . . . . . . . . . D
Output0-30 psig. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 040-75 psig. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 050-150 psig. . . . . . . . . . . . . . . . . . . . . . . . . . . . 07[0-2.0 BAR] . . . . . . . . . . . . . . . . . . . . . . . . . . . 14[0-5.0 BAR] . . . . . . . . . . . . . . . . . . . . . . . . . . . 15[0-10.0 BAR] . . . . . . . . . . . . . . . . . . . . . . . . . . 17(0-200 kPa). . . . . . . . . . . . . . . . . . . . . . . . . . . 24(0-500 kPa). . . . . . . . . . . . . . . . . . . . . . . . . . . 25(0-1000 kPa). . . . . . . . . . . . . . . . . . . . . . . . . . 27
Port Size1/4" NPT (T9000,10,20,40 only) . . . . . . . . . . . . . 023/8" NPT (T9020,40 only) . . . . . . . . . . . . . . . . . . 031/2” NPT (T9020,40 only) . . . . . . . . . . . . . . . . . . 043/4” NPT (T9060,80 only) . . . . . . . . . . . . . . . . . . 061” NPT (T9080 only) . . . . . . . . . . . . . . . . . . . . . . 08
Port ThreadsNPTF Thread . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NBSPT Thread . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UBSPP Thread (Not Available on T9010) . . . . . . . . . . . . . . . . H
Feedback OptionNone. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N0-10 VDC Analog Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 04-20 MA Analog Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40-10 VDC Feedback Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54-20 MA Feedback Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
ElastomersNitrile (Not available in T9040). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NFluorocarbon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . J
Power Failure ModeFreeze (Maintains Setpoint) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F
Exhaust PortTapped . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E
Remote Pressure Sensing Capability (see table below)Unique Feature of the T9000D•DeviceNetTMCommunicationsconnecttheModelT9000D toadigitalnetworktoincreasefunctionalflexibility, installationspeed,andreducesystemwiringcost.
Available Options for the T9000 Series Transducer•Optionalanalogoutputchannelconfiguredasanoutput pressuremonitororasauser-definedoutput.•ExternalPneumaticFeedbackporttosensedownstream pressure.(SeeCablesandAccessoriestable)•OptionalFeedbackInputChannelconfigurabletocontrol setpoint,externalprocessvariable,oracceptauser definedinput.(Consultfactoryforavailability.)
T9000 Cables and Accessories (sold separately)