models vgh-299 ch, vgh-399 ch and vgh-500 ch - slantfin · 2020. 4. 29. · ©2019 slant/fin corp....

4
www.slantfin.com Victory VGH Series High Efficiency Wall Mount Condensing Gas Boiler ® BOILERS & BASEBOARD 1949-2019 2019 1949 B u il d i n g T r u st a n d C o m f o r t • Next Generation Stainless Steel Water Tube Heat Exchanger • Easy Installation & Maintenance • 3 in 1 Vent Connector & Long Vent Lengths • Compact and Light Weight - All Under 188 lbs Boiler Features Control Features ModBus Connection Standard Cascade Control up to 16 Boilers DHW Control Options Including Parallel DHW & CH Operation • Full Text Control & Data Log Remote Access Capable Victory VGH Series • A winning solution Models VGH-299 CH, VGH-399 CH and VGH-500 CH I N T R O D U C I N G

Upload: others

Post on 22-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Models VGH-299 CH, VGH-399 CH and VGH-500 CH - Slantfin · 2020. 4. 29. · ©2019 Slant/Fin Corp. • Publication VGH-10 • Printed in U.S.A. 419 ® BOILERS & BASEBOARD 1949-2019

www.slantfin.com

Victory VGH Series High Efficiency Wall Mount Condensing Gas Boiler

®

BOILERS & BASEBOARD

1949-2019

20191949

Building Trust and Comfort

• Next Generation Stainless Steel Water Tube Heat Exchanger • Easy Installation & Maintenance • 3 in 1 Vent Connector & Long Vent Lengths • Compact and Light Weight - All Under 188 lbs

Boiler Features

Control Features

• ModBus Connection Standard • Cascade Control up to 16 Boilers • DHW Control Options Including Parallel DHW & CH Operation • Full Text Control & Data Log • Remote Access Capable

Victory VGH Series • A winning solution

Models VGH-299 CH, VGH-399 CH and VGH-500 CH INTRODUCING

Page 2: Models VGH-299 CH, VGH-399 CH and VGH-500 CH - Slantfin · 2020. 4. 29. · ©2019 Slant/Fin Corp. • Publication VGH-10 • Printed in U.S.A. 419 ® BOILERS & BASEBOARD 1949-2019

The next generation Duo Stainless Steel Water Tube Heat Exchanger features larger water passages in-creasing the heat output. The lower pressure drop on the water side, contributes to the boilers compact size and, the lower pressure drop on the flue gas side, con-tributes to the longer approved vent lengths. Now you get more heat output in a smaller lightweight package, designed for easy access.

VGH boilers have a fully modulating combustion design featuring a 5:1 turndown ratio. Using stainless steel premix burners, reduces excess air and provides efficient and re-liable direct spark ignition. The VGH can operate with gas pressure as low as 3.5” WC and a negative pressure zero governor gas valve controls the outlet pressure. All models are field convertible to propane by simply changing an orifice and adjusting one control parameter.

Efficiency and reliability are major factors for any boiler installation. But gone are the days of over-sizing boilers to ensure capacity during high demand. Cascades, multiple boilers linked by a control, provide peak performance and opera-tional efficiency; able to adjust capacity based on seasonal demands and occupancy. The VGH onboard control has 4 built-in cascade program modes. It allows for remote operation, control of heating and DHW, as well as boiler sequencing and rotation. A cascade will allow the system to continue to operate if one unit is taking off line for service. And, with seasonal rotation, the wear and tear on a single boiler is decreased, increas-ing the longevity of the system and of your investment. With the ability to cascade up to 16 boilers, the VGH lets you get just the right BTU output for your application.

CASCADES

VENTING

COMBUSTION DESIGN

HEAT EXCHANGER DESIGN

Introducing the VGH Commercial BoilerOur latest boiler boasts efficiencies of 95+, with a stainless steel heat exchanger for durability, superior heating and corrosion resistance and onboard control, all in a compact, lightweight wall mounted design.

The VGH is a direct vent sealed combustion boiler. It features a 3 in 1 exhaust vent and intake air connection. It is rated for vent length up to 481 feet, and is approved for common venting for a cascade system. An integrated combustion analyzer test port is standard on all models. The vent connection is designed to accept PVC, CPVC, Polypropylene and stainless steel, without additional adaptors, saving time and money during installation.

Page 3: Models VGH-299 CH, VGH-399 CH and VGH-500 CH - Slantfin · 2020. 4. 29. · ©2019 Slant/Fin Corp. • Publication VGH-10 • Printed in U.S.A. 419 ® BOILERS & BASEBOARD 1949-2019

Don’t let the small size fool you. This VGH design takes into account mainte-nance and service needs. The control provides a boiler operation history by recording time and date stamps on alarms, lockouts and failed ignitions in the error log. Error codes and text de-scriptions are displayed on the con-trols’ LCD panel. There are easy to download troubleshooting parame-ters available. Since it is wall mounted most compo-nents are at eye level. A flip out panel makes the control easy to use when the cover is removed. Ample front clearance and removable side panels makes easy access to all parts.

CONTROL The feature rich control on the VGH has a large backlit LCD screen with easy-to-read full text information. The control’s extensive data logging captures over 10 parameters, including burner runtime hours, hours till next service, and error logging includes a time and date stamp. Additional features include: CIRCULATOR CONTROLS for the boiler, system and DHW are standard. Additional functions include circulator overrun and exercise, as well as alternate functionality for the dampers and 3-way valves and PWM control for variable speed circulators. DHW CONTROL OPTIONS Includes the expected DHW priority function, but we go above and beyond with additional features such as, parallel DHW and CH operation and an in-stantaneous DHW plate heat exchanger control option. (Plated Heat Exchanger sold separately).

CASCADE Integrated program options can control up to 16 boilers. There are four cascade program modes. They

include, control for both heating and DHW, as well as, boiler sequencing and rotation, as well as, remote operation and heat demand indication from each boiler.

EXTERNAL CONTROL AND BMS OPTIONS with a Modbus connection are standard, as well as, 0-10VDC remote control for set point and boiler input. With the

addition of the IP Module, you are able to check the boiler stats via a computer or smart phone. As added protection for your investment, the VGH includes important features such as, two level frost protection, short cycle protection, adjustable power min-max limits, a temperature Boost function and multiple levels of security.

MAIN PARTS: LCD DISPLAY:

A- Duo Heat Exchanger B- Burner C- Non-Return Valve D- Blower E- Ignition Cable + Electrode

F- Gas Valve G- Display + Boiler Control H- Condensate Siphon I- Air Inlet J- Flue Gas Outlet

K- Boiler Water Return L- Boiler Water Supply M- Flue Gas Test Ports N- Low Water Cut-Off Sensor O- Easy Access Door Clips

A

B

C

D

I

M

J

KL

H

G

F

E

N

O

Page 4: Models VGH-299 CH, VGH-399 CH and VGH-500 CH - Slantfin · 2020. 4. 29. · ©2019 Slant/Fin Corp. • Publication VGH-10 • Printed in U.S.A. 419 ® BOILERS & BASEBOARD 1949-2019

Model

Input, MBHOutput

MBH

AHRI Net Ratings Water, MBH

Thermal Efficiency

%

Combustion Efficiency

%

Max Exhaust/ Intake

Lengths

Supply / Return Connection

Size

Gas Connection

Water Content

Gal (liter)

Empty Weight

Lbs. (kg)

Flue Connection inch (mm)

Min Max

VGH 299 CH 59.0 295 274 238 95.1* – 228'/228' 1 1/2" 1" 1.77 (6.7) 174 (79) 4" (100)

VGH 399 CH 80.0 396 378 329 95.5 95.4 121'/121' 1 1/2" 1" 2.19 (8.3) 182 (83) 4" (100)

VGH 500 CH 98.0 500 476 414 95.1 94.5 451'/451' 1 1/2" 1" 2.74 (10.4) 187 (85) 6" (150)

©2019 Slant/Fin Corp. • Publication VGH-10 • Printed in U.S.A. 419

®

BOILERS & BASEBOARD

1949-2019

20191949

Building Trust and Comfort

U.S.A. Slant/Fin Corporation • 100 Forest Drive Greenvale, NY 11548 • 516-484-2600 www.slantfin.com

Canada Slant/Fin LTD/LTEE • 400 Ambassador Drive, Mississauga, Ontario L5T 2 J3 • 905-677-8400 www.slantfin.ca

• Gas-Fired • High Efficiency • Wall Mount • Energy Star Rated*

Polypropylene, PVC, CPVC, and Stainless steel venting is standard.

Victory VGH Series • A winning solution

Models VGH-299, VGH-399 and VGH-500

6 in

[140

.4 m

m]

33.3

in[8

45.0

mm

]

2.7

in[6

9.5

mm

]

6.9

in[1

76.5

mm

]

2.7

in[6

9.5

mm

]4 in (2x)[DN100 mm]

9.9

in[2

50.6

mm

]

7.1

in[1

79.4

mm

]

9.6

in[2

44.6

mm

]

7.3

in[1

85.4

mm

]

7.4 in[187.5 mm]

7.4 in[187.5 mm]

17.4 in[442.0 mm]

8.9 in[226.5 mm]

9.2 in[234.1 mm]

4.8

in[1

21.2

mm

]

12.8

in[3

25.2

mm

]

21.2

2 in

[539

.0 m

m]

4.4 in[111.8 mm]

4.7 in[119.3 mm]

9 in[228.5 mm]

9.2 in[234.5 mm]

21.2

in[5

39.0

mm

]

3.5 in[88.5 mm]

3.7 in[94.5 mm]

3.7 in[94.5 mm]

5.9

in[1

48.8

mm

]B

4 in

[101

.8 m

m]

C

B C

WINNING PERFORMANCE

It’s been said that good things come in small pack-ages; the VGH high effi-ciency boiler is proof of that. Compact 33.3 x 17.3 x 20.9 inches (h x w d) and light weight – under 188 lbs. The VGH series of wall mounted boilers is one of the small-est, lightest and most pow-erful boilers in its class. Its small size and light weight make for easy and flexible installation options without the need of specialized transportation tools.

• Stainless Steel ASME heat exchanger • Certified for use with Common venting system • Unique locking wall bracket • Condensate trap clean out & drain • Built in 3 in 1 vent connector • Control- Includes outdoor reset sensor • 50 p.s.i relief valve

STANDARD EQUIPMENT

Gas Consumption

Model Nat. Gas ft3/h (m3/h) Propane ft3/h (m3/h)VGH 299 CH 52-261 (1.5-7.4) 22.2-111 (0.6-3.1)VGH 399 CH 73.9-372 (2.1-10.5) 31.3-157 (0.9-4.5)VGH 500 CH 91.5-482 (2.6-13.6) 38.7-204 (1.1-5.8)

* AFUE VGH-299 CH is Energy Star Rated