mono & multi - technibeltechnibel.info › wp-content › uploads › 2013 › 11 ›...

10
MONO & MULTI SPLIT AIR CONDITIONERS

Upload: others

Post on 25-Jun-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MONO & MULTI - Technibeltechnibel.info › wp-content › uploads › 2013 › 11 › ARGO-X3_MONO_M… · HI-WALL X3I HL CASSETTE X3I AS X3I SD X3I FC X3I AF Btu/h 9000 12000 18000

MONO & MULTI

SPLIT AIR CONDITIONERS

Page 2: MONO & MULTI - Technibeltechnibel.info › wp-content › uploads › 2013 › 11 › ARGO-X3_MONO_M… · HI-WALL X3I HL CASSETTE X3I AS X3I SD X3I FC X3I AF Btu/h 9000 12000 18000

INVERTER TECHNOLOGY ENERGY CLASS

SINGLE SPLIT DCI

IR REMOTE

www.argoclima.com

Low ConsumptionLow Noise LevelPrecise temperature set

Inverter technology: low consumption, low noise, more precise temperature control

ERP compliant; just 0.5 watt consumption in stand-by Compact & Linear Design, high-gloss pure white finishing Central very discreet display on the front panel Digital remote control with LCD display Different airflow settings; 4 fan speeds Programmable timer I feel: ensures the desired temperature in the precise place where

you place the remote control Turbo Function

Memory Function Comfortable Sleep mode Auto clean of the indoor heat exchanger Intelligent defrost: defrost process is not activated unnecessarily,

allowing significant energy saving Cold draft prevention: it prevents cold air entering during the

heating function Low Voltage start-up: low consumption at start-up, no impact on

the use of other electrical appliances Self-diagnosis Optimized airflow in cooling and heating

X3 DC inverter series is highly efficient and provides immediate and continuous comfort with low energy consumption.Moreover, some technological features are designed to reduce peak consumption to improve the functioning at low temperatures.

Cold plasma air purification system Air sterilization with removing over 90% of bacteria

Odors removal Improved air quality thanks to negative ions increasing

Standby 0,5W

Cold Plasma iFeel Energy Saving

3 Sleep CurveComfortable

Cold Air Prevention

Led Display Timer Intelligent Defrosting

Auto Clean Turbo Button Self-Diagnosis Dehumidification Auto Restart

-15°C Cooling -20°C Heating

2

Page 3: MONO & MULTI - Technibeltechnibel.info › wp-content › uploads › 2013 › 11 › ARGO-X3_MONO_M… · HI-WALL X3I HL CASSETTE X3I AS X3I SD X3I FC X3I AF Btu/h 9000 12000 18000

MODEL (Indoor unit / Outdoor unit) X3I 27 (X3I 27 HL / X3I 27 SH) X3I 35 (X3I 35 HL / X3I 35 SH)

Units Cooling Heating Cooling Heating

Capacity (nominal-min.-max.) (EN14511) kW 2,6 (0,45-3,23) 2,8 (0,45-4,1) 3,5 (0,6-3,96) 3,67 (0,6-5,13)BTU/h 9000 9000 12000 12000

EER/COP (EN14511) 3,23 3,71 3,23 3,71Design Load (Pdesign c /Pdesign h)(Avarage/Warmer/Colder) (EN14825) kW 2,6 2,6/2,8/2,6 3,5 3,0/3,8/3,0

Seasonal efficiency ratio (SEER / SCOP (Average/Warmer/Colder) (EN14825) 6,1 4,0/5,1/3,2 6,1 4,0/5,1/3,2

Energy efficiency class A++ A+/A+++/B A++ A+/A+++/BAnnual energy consumption C/H(Avarage/Warmer/Colder)

kWh/annum 149 910/769/1706 201 1050/1043/1969

Air flowrate Indoor (sh.-h.-m.-l.) m³/h 560-490-430-330 660-540-460-330Dehumidification l/h 0,8 1,4Fan speeds (Indoor / Outdoor) n° 4/2 4/2Sound pressure Indoor (sh.-h.-m.-l.) dB(A) 39-36-32-26 42-39-33-26Sound pressure Outdoor (h.) dB(A) 52 53Sound power Indoor (sh.-h.-m.-l.) dB(A) 55-52-44-38 57/53/45/42Sound power Outdoor (h.) dB(A) 61 62Power supply V/Ph/Hz 230/1/50 230/1/50Power input kW 0,805 0,755 1,084 0,989Compressor type Rotary DC Inverter Rotary DC InverterRefrigerant type R410A R410ARefrigerant charge kg/T.CO2 eq. 0,7/1,46 0,85/1,77Liquid pipe diameter mm (") 6,35(1/4") 6,35(1/4")Gas pipe diameter mm (") 9,52(3/8") 9,52(3/8")Max. pipe lenght with gas standard charge m 5 5Max. pipe lenght m 15 20Additional refrigerant charge g/m 20 20Max. height between units (Outdoor on top) m 10 10Max. height between units (Indoor on top) m 10 10Net dimension Indoor (H./W./D.) mm 275x790x200 289x845x209Net dimension Outdoor (H./W./D.) mm 540x776x320 540x776x320Net weight Indoor / Outdoor Kg 9/28 10/29

MODEL (Indoor unit / Outdoor unit) X3I 52 (X3I 52 HL / X3I 52 SH) X3I 64 (X3I 64 HL / X3I 64 SH)

Units Cooling Heating Cooling Heating

Capacity (nominal-min.-max.) (EN14511) kW 5,13 (1,26-6,6) 5,28 (1,12-6,8) 6,7 (2,0-8,2) 7,25 (2,0-8,5)BTU/h 18000 18000 24000 24000

EER/COP (EN14511) 3,25 3,74 3,25 3,74Design Load (Pdesign c /Pdesign h)(Avarage/Warmer/Colder) (EN14825) kW 5,1 4,1/5,3/6,2 6,7 6,4/7,1/6,4

Seasonal efficiency ratio (SEER / SCOP (Average/Warmer/Colder) (EN14825) 6,1 4,0/5,4/3,1 6,3 4,0/5,1/2,8

Energy efficiency class A++ A+/A+++/B A++ A+/A+++/CAnnual energy consumption kWh/annum 293 1435/1374/4200 373 2240/1949/4800Air flowrate Indoor (sh.-h.-m.-l.) m³/h 800-720-610-520 1150-1050-950-850Dehumidification l/h 1,8 2,4Fan speeds (Indoor / Outdoor) n° 4/2 4/2Sound pressure Indoor (sh.-h.-m.-l.) dB(A) 46-42-39-36 48-45-42-39Sound pressure Outdoor (h.) dB(A) 56 60Sound power Indoor (sh.-h.-m.-l.) dB(A) 58-54-51-48 64-59-56-53Sound power Outdoor (h.) dB(A) 63 68Power supply V/Ph/Hz 230/1/50 230/1/50Power input kW 1,58 1,41 1,875 1,945Compressor type Rotary DC Inverter Rotary DC InverterRefrigerant type R410A R410ARefrigerant charge kg/T.CO2 eq. 1,3/2,71 1,9/3,97Liquid pipe diameter mm (") 6,35(1/4") 6,35(1/4")Gas pipe diameter mm (") 12,7(1/2") 15,88 (5/8")Max. pipe lenght with gas standard charge m 5 5Max. pipe lenght m 25 25Additional refrigerant charge g/m 20 20Max. height between units (Outdoor on top) m 10 10Max. height between units (Indoor on top) m 10 10Net dimension Indoor (H./W./D.) mm 300x970x224 325x1078x246Net dimension Outdoor (H./W./D.) mm 700x955x396 700x955x396Net weight Indoor / Outdoor Kg 13,5/45 17/53

Data declared in compliance with EU Regulation no. 206/2012, as regards to Ecodesign requirements for air conditioners and comfort fans, and EU Regulation no. 626/2011, concerning the energy labelling of air conditioners, and tested according to standard EN14825.

OPERATING RANGE (outdoor temperature)Cooling mode: from -15°C to +43°CHeating mode: from -20°C to +24°CTemperature setting range: 16-30°C

www.argoclima.com

Technical data

3

Page 4: MONO & MULTI - Technibeltechnibel.info › wp-content › uploads › 2013 › 11 › ARGO-X3_MONO_M… · HI-WALL X3I HL CASSETTE X3I AS X3I SD X3I FC X3I AF Btu/h 9000 12000 18000

MULTISPLIT DCI

ChildLock

EnergySaving

Timer 24h WeeklyTimer

R410A EasyMaintenance

HighEfficiency

Auto RestartMemory

IntelligentDefrosting

“Turbo”function

€Wide

Voltage

FREE MATCH

W

TURBO

V

Auto-diagnosis

Low voltageStart-up

HI-WALL

X3I HL

CASSETTE

X3I AS

X3I SD

X3I FC

X3I AF

2400018000120009000Btu/h

DUCTED

CONSOLE

FLOOR-CEILING

DC INVERTER TECHNOLOGY

WIDE RANGE

LOW AMBIENT COOLING

SEVERAL MATCHINGS Possibility of choice among different types of indoor units, meeting any need

(105 Model)

Low Consumption

Low Noise Level

Precise temperature control

All models can work up to -15°C in cooling mode, except only for model 105 (-5°C)

Capacity range from 14 to 42000 BTU/h

Widely used in residential houses, hotel, business offices

www.argoclima.com

ENERGY CLASS

X3I 27 HL - X3I FC27HL - X3I AF27HL 9000

Btu/h INDOOR UNIT MODELS

X3I 35 HL - X3I AS35HL - X3I SD35HL X3I FC52HL - X3I AF35HL 12000

18000

24000

X3I 52 HL - X3I AS52HL - X3I SD52HLX3I FC52HL - X3I AF52HL X3I 64 HL

4

Page 5: MONO & MULTI - Technibeltechnibel.info › wp-content › uploads › 2013 › 11 › ARGO-X3_MONO_M… · HI-WALL X3I HL CASSETTE X3I AS X3I SD X3I FC X3I AF Btu/h 9000 12000 18000

DUAL/TRIAL SPLIT

Type IU IU

OU X3MI 41SH 9000 90009000 12000

Type IU IU9000 9000

OU X3MI 52SH 9000 1200012000 12000

Type IU IU IU9000 90009000 120009000 18000

OU X3MI 61SH 12000 1200012000 180009000 9000 90009000 9000 1200012000 12000 12000

Type IU IU IU9000 90009000 120009000 1800012000 1200012000 18000

OU X3MI 71SH 18000 180009000 9000 90009000 9000 120009000 9000 180009000 12000 1200012000 12000 12000

QUADRI SPLIT

Type IU IU IU IU9000 90009000 120009000 1800012000 1200012000 1800018000 180009000 9000 90009000 9000 120009000 9000 180009000 12000 180009000 12000 1200012000 12000 180009000 12000 180009000 9000 1800012000 12000 120009000 9000 9000 90009000 9000 9000 120009000 9000 12000 12000

OU X3MI 80SH

Matchings

Controllers

INDOOR UNIT TYPES

CONTROLLERS

DUCTEDHI-WALL FLOOR/CEILINGCASSETTE CONSOLE

www.argoclima.com 5

Page 6: MONO & MULTI - Technibeltechnibel.info › wp-content › uploads › 2013 › 11 › ARGO-X3_MONO_M… · HI-WALL X3I HL CASSETTE X3I AS X3I SD X3I FC X3I AF Btu/h 9000 12000 18000

PENTA SPLIT

Type IU IU IU IU IU

9000 120009000 180009000 2400012000 1200012000 1800012000 2400018000 1800018000 2400024000 240009000 9000 90009000 9000 120009000 9000 180009000 9000 240009000 12000 120009000 12000 180009000 12000 240009000 18000 180009000 18000 2400012000 12000 1200012000 12000 1800012000 12000 2400012000 18000 1800012000 18000 2400012000 24000 2400018000 18000 1800018000 18000 240009000 9000 9000 90009000 9000 9000 120009000 9000 9000 180009000 9000 9000 240009000 9000 12000 120009000 9000 12000 240009000 9000 18000 180009000 9000 18000 180009000 12000 12000 120009000 12000 12000 1800012000 12000 12000 1200012000 12000 12000 180009000 9000 9000 9000 90009000 9000 9000 9000 120009000 9000 9000 9000 180009000 9000 9000 12000 120009000 9000 12000 12000 12000

OU X3MI 120SH

Type IU IU IU IU9000 90009000 120009000 180009000 2400012000 1200012000 1800012000 2400018000 1800018000 2400024000 240009000 9000 90009000 9000 120009000 9000 180009000 9000 240009000 12000 120009000 12000 180009000 12000 240009000 18000 180009000 18000 2400012000 12000 1200012000 12000 1800012000 12000 2400012000 18000 1800012000 18000 240009000 9000 9000 90009000 9000 9000 120009000 9000 9000 180009000 9000 9000 240009000 9000 12000 120009000 9000 12000 180009000 9000 18000 180009000 12000 12000 120009000 12000 12000 1800012000 12000 12000 12000

X3MI 105SHOU

QUADRI SPLIT

Matchings

www.argoclima.com6

Page 7: MONO & MULTI - Technibeltechnibel.info › wp-content › uploads › 2013 › 11 › ARGO-X3_MONO_M… · HI-WALL X3I HL CASSETTE X3I AS X3I SD X3I FC X3I AF Btu/h 9000 12000 18000

Technical data - Outdoor units

OUTDOOR MODEL - DUAL SPLIT X3MI 41SH X3MI 52SHUnits Cooling Heating Cooling Heating

Capacity (nominal-min.-max.) (EN14511) kW 4,1 (2,05-4,40) 4,4 (2,49-5,42) 5,2 (2,14-5,84) 5,4 (2,58-5,51)BTU/h 14000 15000 17750 18430

EER/COP (EN14511) 3,42 3,73 3,59 3,48Design Load (Pdesign c /Pdesign h)(Avarage/Warmer/Colder) (EN14825) kW 4,1 3,8 5,2 5,0

Seasonal efficiency ratio (SEER / SCOP (Average/Warmer/Colder) 6,1 4,0 6,3 4,0

Energy efficiency class A++ A+ A++ A+Annual energy consumption C/H(Avarage/Warmer/Colder) kWh/annum 235 1330 288 1750

Numero minimo-max unità interne collegabili no. 2 2Air flowrate m³/h 2600 3200Fan speeds Outdoor n° 2 2Sound pressure Outdoor (sh.-h.-m.-l.) dB(A) 55 56Sound power Outdoor (h.) dB(A) 62 62Power supply V/Ph/Hz 230/1/50 230/1/50Power input kW 1,2 1,18 1,45 1,55Compressor type Rotary DC Inverter Rotary DC InverterRefrigerant type R410A R410ARefrigerant charge kg/T.CO2 eq. 1,4/2,92 1,6/3,34Liquid pipe diameter mm (") 6,35(1/4") 6,35(1/4")Gas pipe diameter mm (") 9,52(3/8") 9,52(3/8")Min./Max. pipe lenght with gas standard charge m 3-10 3-10Max. pipe lenght with additional charge m 20 20Additional refrigerant charge g/m 20 20Max. height between units (Outdoor on top) m 5 5Max. height between units (Indoor on top) m 5 5Net dimension Outdoor (H./W./D.) mm 596x899x378 700x955x396Net weight Kg 43 51

OUTDOOR MODEL - TRIAL SPLIT X3MI 61SH X3MI 71SHUnits Cooling Heating Cooling Heating

Capacity (nominal-min.-max.) (EN14511) kW 6,1 (2,2-7,33) 6,5 (3,61-8,5) 7,1(2,29-8,5) 8,5 (3,66-8,79)BTU/h 20820 22180 24230 29000

EER/COP (EN14511) 3,19 3,76 3,26 3,73Design Load (Pdesign c /Pdesign h)(Avarage/Warmer/Colder) (EN14825) kW 6,1 5,8 7,1 7,0

Seasonal efficiency ratio (SEER / SCOP (Average/Warmer/Colder) 6,1 4,0 6,1 4,0

Energy efficiency class A++ A+ A++ A+Annual energy consumption C/H(Avarage/Warmer/Colder) kWh/annum 350 2030 407 2450

Numero minimo-max unità interne collegabili no. 2-3 2-3Air flowrate m³/h 3200 4000Fan speeds Outdoor n° 2 2Sound pressure Outdoor (sh.-h.-m.-l.) dB(A) 56 58Sound power Outdoor (h.) dB(A) 65 65Power supply V/Ph/Hz 230/1/50 230/1/50Power input kW 1,91 1,73 2,18 2,28Compressor type Rotary DC Inverter Rotary DC InverterRefrigerant type R410A R410ARefrigerant charge kg/T.CO2 eq. 2,2/4,59 2,2/4,59Liquid pipe diameter mm (") 6,35(1/4") 6,35(1/4")Gas pipe diameter mm (") 9,52(3/8") 9,52(3/8")Min./Max. pipe lenght with gas standard charge m 3-30 3-30Max. pipe lenght with additional charge m 60 60Additional refrigerant charge g/m 20 20Max. height between units (Outdoor on top) m 10 10Max. height between units (Indoor on top) m 10 10Net dimension Outdoor (H./W./D.) mm 700x955x396 790x980x427Net weight Kg 62 68

Data declared in compliance with EU Regulation no. 206/2012, as regards to Ecodesign requirements for air conditioners and comfort fans, and EU Regulation no. 626/2011, concerning the energy labelling of air conditioners, and tested according to standard EN14825.

OPERATING RANGE mod. 41-52-61-71 (outdoor temperature)Cooling mode: from -15°C to +43°CHeating mode: from -20°C to +24°CTemperature setting range: 16-30°C

www.argoclima.com 7

Page 8: MONO & MULTI - Technibeltechnibel.info › wp-content › uploads › 2013 › 11 › ARGO-X3_MONO_M… · HI-WALL X3I HL CASSETTE X3I AS X3I SD X3I FC X3I AF Btu/h 9000 12000 18000

Technical data - Outdoor units

www.argoclima.com

OUTDOOR MODEL - QUADRI SPLIT X3MI 80SH X3MI 105SHUnits Cooling Heating Cooling Heating

Capacity (nominal-min.-max.) (EN14511) kW 8,0 (2,29-10,26) 9,30 (3,66-10,26) 10,5 (2,1-11) 11(2,6-13)BTU/h 27300 31730 35830 37530

EER/COP (EN14511) 3,23 3,71 3,00 2,93Design Load (Pdesign c /Pdesign h)(Avarage/Warmer/Colder) (EN14825) kW 8,0 7,0 10,5 10,5

Seasonal efficiency ratio (SEER / SCOP (Average/Warmer/Colder) 6,1 4,0 5,50 3,80

Energy efficiency class A++ A+ A+ AAnnual energy consumption C/H(Avarage/Warmer/Colder) kWh/annum 459 2450 668 3876

Numero minimo-max unità interne collegabili no. 2-4 2-4Air flowrate m³/h 4000 5200Fan speeds Outdoor n° 2 2Sound pressure Outdoor (sh.-h.-m.-l.) dB(A) 58 57Sound power Outdoor (h.) dB(A) 65 67Power supply V/Ph/Hz 230/1/50 230/1/50Power input kW 2,54 2,49 3,50 3,75Compressor type Rotary DC Inverter Rotary DC InverterRefrigerant type R410A R410ARefrigerant charge kg/T.CO2 eq. 2,4/5,01 4,3/8,98Liquid pipe diameter mm (") 6,35(1/4") 6,35(1/4")Gas pipe diameter mm (") 9,52(3/8") 9,52(3/8")Min./Max. pipe lenght with gas standard charge m 3-40 3-40Max. pipe lenght with additional charge m 70 70Additional refrigerant charge g/m 20 22Max. height between units (Outdoor on top) m 10 15Max. height between units (Indoor on top) m 10 15Net dimension Outdoor (H./W./D.) mm 790x980x427 1103x1015x440Net weight Kg 69 94

OUTDOOR MODEL - PENTA SPLIT X3MI 120SH Units Cooling Heating

Capacity (nominal-min.-max.) (EN14511) kW 12,1 (2,1-13,6 13 (2,6-14)BTU/h 41300 44360

EER/COP (EN14511) 3,37 3,66Design Load (Pdesign c /Pdesign h)(Avarage/Warmer/Colder) (EN14825) kW nd>12kW nd>12kW

Seasonal efficiency ratio (SEER / SCOP (Average/Warmer/Colder) nd>12kW nd>12kW

Energy efficiency class nd>12kW nd>12kWAnnual energy consumption C/H(Avarage/Warmer/Colder) kWh/annum nd>12kW nd>12kW

Numero minimo-max unità interne collegabili no. 2-5Air flowrate m³/h 5500Fan speeds Outdoor n° 2Sound pressure Outdoor (sh.-h.-m.-l.) dB(A) 54Sound power Outdoor (h.) dB(A) 64Power supply V/Ph/Hz 230/1/50Power input kW 3,59 3,55Compressor type Rotary DC InverterRefrigerant type R410ARefrigerant charge kg/T.CO2 eq. 4,8/10,02Liquid pipe diameter mm (") 6,35(1/4")Gas pipe diameter mm (") 9,52(3/8")Min./Max. pipe lenght with gas standard charge m 3-40Max. pipe lenght with additional charge m 70Additional refrigerant charge g/m 22Max. height between units (Outdoor on top) m 15Max. height between units (Indoor on top) m 15Net dimension Outdoor (H./W./D.) mm 1103x1015x440Net weight Kg 102

Data declared in compliance with EU Regulation no. 206/2012, as regards to Ecodesign requirements for air conditioners and comfort fans, and EU Regulation no. 626/2011, concerning the energy labelling of air conditioners, and tested according to standard EN14825.

OPERATING RANGE mod. 80 (outdoor temperature) OPERATING RANGE mod. 105/120 (outdoor temperature)Cooling mode: from -5°C to +48°CHeating mode: from -15°C to +24°CTemperature setting range: 16-30°C

Cooling mode: from -15°C to +43°CHeating mode: from -20°C to +24°CTemperature setting range: 16-30°C

8

Page 9: MONO & MULTI - Technibeltechnibel.info › wp-content › uploads › 2013 › 11 › ARGO-X3_MONO_M… · HI-WALL X3I HL CASSETTE X3I AS X3I SD X3I FC X3I AF Btu/h 9000 12000 18000

Technical data - Indoor units

HI-WALL INDOOR UNITS X3I 27 HL X3I 35 HL X3I 52 HL X3I 64 HL Units Cooling Heating Cooling Heating Cooling Heating Cooling Heating

Capacity kW 2,6 2,8 3,5 3,7 5,13 5,28 6,7 7,25Air flowrate m³/h 560-490-430-330 660-540-460-330 800-720-610-520 1150-1050-950-850Dehumidification l/h 0,8 1,4 1,8 2,4Fan speeds n° 4 4 4 4Sound pressure (sh.-h.-m.-l.) dB(A) 39-36-32-26 42-39-33-26 46-42-39-36 48-45-42-39Sound power U.I. (sh.-h.-m.-l.) dB(A) 53-49-45-39 57-53-45-42 58-54-51-48 64-59-56-53Liquid pipe diameter mm(inch") 6,35(1/4") 6,35(1/4") 6,35(1/4") 6,35(1/4")Gas pipe diameter mm(inch") 9,52(3/8") 9,52(3/8") 12,7(1/2") 15,88 (5/8")Net dimension (H./W./D.) mm 275/790/200 289/845/209 300/970/224 325/1078/246Net weight kg 9 10 13,5 17

CASSETTE INDOOR UNITS X3I AS35HL X3I AS52HL Units Cooling Heating Cooling Heating

Capacity kW 3,5 4,0 4,5 5,0Air flowrate m³/h 600 600Dehumidification l/h 1,4 1,8Fan speeds n° 3+auto 3+autoSound pressure (sh.-h.-m.-l.) dB(A) 46-44-42 46-44-42Sound power U.I. (sh.-h.-m.-l.) dB(A) 56-54-52 56-54-52Liquid pipe diameter mm(inch") 6,35(1/4") 6,35(1/4")Gas pipe diameter mm(inch") 9,52(3/8") 12,7 (1/2")Unit net dimension without panel (H./W./D.) mm 230/570/570 230/570/570

Panel net dimension (H./W./D.) mm 50/650/650 50/650/650Unit net weight without panel kg 18 18Panel net weight kg 2,5 2,5

DUCTED INDOOR UNITS X3I SD27HL X3I SD35HL X3I SD52HL Units Cooling Heating Cooling Heating Cooling Heating

Capacity kW 2,50 2,80 3,5 3,85 5,0 5,5Air flowrate m³/h 450 500 700Static pressure min-max Pa 0-10 0-10 0-10Dehumidification l/h 0,8 1,4 1,8Fan speeds n° 3+auto 3+auto 3+autoSound pressure (sh.-h.-m.-l.) dB(A) 37-34-31 39-35-32 41-36-33Sound power U.I. (sh.-h.-m.-l.) dB(A) 47-44-41 49-45-42 50-46-43Liquid pipe diameter mm(inch") 6,35(1/4") 6,35(1/4") 6,35(1/4")Gas pipe diameter mm(inch") 9,52(3/8") 9,52(3/8") 12,7 (1/2")Net dimension (H./W./D.) mm 200/700/615 200/700/615 200/900/615Net weight kg 22 23 27

FLOOR/CEILING INDOOR UNITS X3I FC27HL X3I FC35HL X3 FC52HL Units Cooling Heating Cooling Heating Cooling Heating

Capacity kW 2,5 2,8 3,5 3,85 5,0 5,5Air flowrate m³/h 650-550-450 650-550-450 950-700-500

Dehumidification l/h 0,8 1,4 1,8Fan speeds n° 7 7 7Sound pressure (sh.-h.-m.-l.) dB(A) 40-38-36 40-38-36 45-42-40Sound power U.I. (sh.-h.-m.-l.) dB(A) 50-48-46 50-48-46 55-52-50Liquid pipe diameter mm(inch") 6,35(1/4") 6,35(1/4") 6,35(1/4")Gas pipe diameter mm(inch") 9,52(3/8") 9,52(3/8") 12,7 (1/2")Net dimension (H./W./D.) mm 225/1220/700 225/1220/700 225/1220/700Net weight kg 40 40 40

CONSOLE INDOOR UNITS X3I AF27HL X3I AF35HL X3I AF52HLUnits Cooling Heating Cooling Heating Cooling Heating

Capacity kW 2,5 2,8 3,5 3,85 5,3 5,8Air flowrate m³/h 500-430-410-370-330-280-250 600-520-480-440-400-360-280 650-620-550-500-450-410-320

Dehumidification l/h 0,8 1,4 1,8Fan speeds n° 7 7 7Sound pressure (sh.-h.-m.-l.) dB(A) 40-38-36-33-30-27-25 42-40-38-37-35-32-27 48-46-44-41-37-35-32Sound power U.I. (sh.-h.-m.-l.) dB(A) 55-53-51-48-45-42-40 57-55-53-52-50-47-42 62-59-57-55-52-50-47Liquid pipe diameter mm(inch") 6,35(1/4") 6,35(1/4") 6,35(1/4")Gas pipe diameter mm(inch") 9,52(3/8") 9,52(3/8") 12,7 (1/2")Net dimension (H./W./D.) mm 600/700/215 600/700/215 600/700/215Net weight kg 15 15 15

www.argoclima.com 9

Page 10: MONO & MULTI - Technibeltechnibel.info › wp-content › uploads › 2013 › 11 › ARGO-X3_MONO_M… · HI-WALL X3I HL CASSETTE X3I AS X3I SD X3I FC X3I AF Btu/h 9000 12000 18000

Head officeVia Alfeno Varo, 3525020 Alfianello (BS) ITALYTel: + 39 0331 755111Fax: + 39 0331 775501www.argoclima.com

www.argoc l ima .com

7020

1700

3 - 0

3/20

17

N.B. The manufacturer assumes no responsability for any errors or inaccuracies regarding the contents of this catalogue, and reserves the right to make any necessary changes to its products, at any time and without prior notice, for technical or commercial reasons.

Argo is a brand of , a leading European company in Air Conditioning, Heating and Air Treatment.