more performance. simplified. u-remote. · 2020. 8. 13. · simplified. u-remote. in 2017: our...

28
More Performance. Simplified. u-remote. June 2020 Product Presentation Mareks Jakubovskis Sales and Market Development Manager Latvia

Upload: others

Post on 21-Aug-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: More Performance. Simplified. u-remote. · 2020. 8. 13. · Simplified. u-remote. In 2017: Our features - your benefit 8 fieldbus gateways Flexible migration of I/Os to your target

More Performance. Simplified.

u-remote.

June 2020

Product Presentation

Mareks Jakubovskis

Sales and Market Development Manager Latvia

Page 2: More Performance. Simplified. u-remote. · 2020. 8. 13. · Simplified. u-remote. In 2017: Our features - your benefit 8 fieldbus gateways Flexible migration of I/Os to your target

u-remote - the new IP20 Remote I/O System from Weidmüller

More Performance. Simplified.

u-remote.

Fieldbus coupler / Gateway I/O modules

Page 3: More Performance. Simplified. u-remote. · 2020. 8. 13. · Simplified. u-remote. In 2017: Our features - your benefit 8 fieldbus gateways Flexible migration of I/Os to your target

u-remote - the fieldbus coupler

►"Head" of the system

►Gateway between internal bus and network

► Integrated power supply for system and I/Os

► Micro-USB as service interface

More Performance. Simplified.

u-remote.

Page 4: More Performance. Simplified. u-remote. · 2020. 8. 13. · Simplified. u-remote. In 2017: Our features - your benefit 8 fieldbus gateways Flexible migration of I/Os to your target

u-remote - the I/O module

►I/O interface

►Removable terminal unit

►Individually removable connectors (4x4pin)

►Exchangeable Electronics

►Rail mounted base with contacts for

►Internal communication

►supplying power to the system

►supplying power to the input modules

►supplying power to the output modules

►Mechanical parts in orange for toolless handling

More Performance. Simplified.

u-remote.

Page 5: More Performance. Simplified. u-remote. · 2020. 8. 13. · Simplified. u-remote. In 2017: Our features - your benefit 8 fieldbus gateways Flexible migration of I/Os to your target

u-remote – we understand the needs of our customers engineering

► Significantly reduce space

► Flexible engineering and simplified planning

► Faster assembly and less failures

► Minimised downtime

More Performance. Simplified.

u-remote.

Page 6: More Performance. Simplified. u-remote. · 2020. 8. 13. · Simplified. u-remote. In 2017: Our features - your benefit 8 fieldbus gateways Flexible migration of I/Os to your target

Slim design @ 11.5 mm

Save space in your cabinet

Pluggable connectors

Fast exchange of signal wiring in service case

Separate I/O current paths 2 x 10 A

Less supply modules and isolation of

in- and outputs

More Performance. Simplified.

u-remote.

Our features - your benefit

Push In connection

Quick and toolless wire assembly

Page 7: More Performance. Simplified. u-remote. · 2020. 8. 13. · Simplified. u-remote. In 2017: Our features - your benefit 8 fieldbus gateways Flexible migration of I/Os to your target

Individual QR-Codes

Quick access to

documentation

More Performance. Simplified.

u-remote.

Integrated Web-Server

Improved comissioning and diagnosis

LED on the module and at each channel

Clear and fast status identification

Our features - your benefit

Single row design

Clear allocation of wiring

Page 8: More Performance. Simplified. u-remote. · 2020. 8. 13. · Simplified. u-remote. In 2017: Our features - your benefit 8 fieldbus gateways Flexible migration of I/Os to your target

Worldwide approvals

Global usability in your applications

More Performance. Simplified.

u-remote.

In 2017:

Our features - your benefit

8 fieldbus gateways

Flexible migration of I/Os

to your target application

Up to 64 modules with one system supply

Reduced no. of fieldbus nodes, high I/O

density

Modular system with hot-swap capability

Toolless exchange of electronic on powered

station

Page 9: More Performance. Simplified. u-remote. · 2020. 8. 13. · Simplified. u-remote. In 2017: Our features - your benefit 8 fieldbus gateways Flexible migration of I/Os to your target

u-remote – UR20 portfolio (to be continued…)

Fieldbus coupler (Gateways):

► PROFIBUS DP V1

► PROFINET IRT

► EtherCAT

► Modbus TCP

► Modbus TCP Dual LAN

► Ethernet/IP

► DeviceNet

► CANopen

► Powerlink

Digital Outputs:

► 16 DO, 0,5 A

► 8 DO, 0,5 A

► 4 DO, 0,5 A & 2 A

► 4 Change over relay, 6 A

► 4 Solid state relay, 1 A

Digital Inputs:

► 16 DI

► 8 DI

► 4 DI

►120/ 230 V AC

Integrated safety:

► Powerfeed for emergency shut-

down of Output modules

► 8DI, 4DI/4DO►PROFIsafe

►FSOE

Functional modules:

► Counter (100 kHz, gate,

latch, reset function)

► Fast counter (500 kHZ)

► PWM (0,5A & 2A)

►3 phase Energy Metering

230V/5A AC

More Performance. Simplified.

u-remote.

Analogue Inputs:

► 8 AI, 0/4 to 20 mA

► 4 AI, ±10V, 0/4 to 20 mA

► 4 AI, RTD

► 4 AI, TC

► Potentiometer inputs

► Load cell inputs

► Differential inputs

Analogue Outputs:

► 4 AO, ±10V, 0/4 to 20 mA

Serial communication:

► SSI interface

► RS232/RS485/RS422

► SAI gateway module

► IO-Link Master

Page 10: More Performance. Simplified. u-remote. · 2020. 8. 13. · Simplified. u-remote. In 2017: Our features - your benefit 8 fieldbus gateways Flexible migration of I/Os to your target

Highest performance for centralized or distributed safety architectures

Integration of safety modules in standard and remote stations

Efficient, modular, flexible

Support for commissioning, maintenance and diagnostics via integrated web server

►Safety Power-Feed modules and safety I/O modules

u-remote - integrated safety for the plant automation

More Performance. Simplified.

u-remote.

Page 11: More Performance. Simplified. u-remote. · 2020. 8. 13. · Simplified. u-remote. In 2017: Our features - your benefit 8 fieldbus gateways Flexible migration of I/Os to your target

►The safe Power-Feed module for u-remote is in this way unique in the market

►Designed for discreet, lean and efficient safety solutions to come up with only one or two

emergency stop circuits off simultaneously or delayed several outputs safely

►The safe shutdown of the supply current path for the following outputs does not require

expensive safety controller

►By using several safety Power-Feed modules it is possible to build up different safety

segments

►By cascading, a safety hierarchy can be installed in one station

Fieldbus

Safety Feed-In

module

u-remote - discrete safety solutions without safety PLC

More Performance. Simplified.

u-remote.

Page 12: More Performance. Simplified. u-remote. · 2020. 8. 13. · Simplified. u-remote. In 2017: Our features - your benefit 8 fieldbus gateways Flexible migration of I/Os to your target

More Performance. Simplified.

u-remote.

u-remote - discrete safety solutions without safety PLC

Page 13: More Performance. Simplified. u-remote. · 2020. 8. 13. · Simplified. u-remote. In 2017: Our features - your benefit 8 fieldbus gateways Flexible migration of I/Os to your target

u-remote - discrete safety solutions without safety PLC

UR20-PF-O-1DI-SIL

► Connection for one emergency

stop circuit

► SIL 3 safety standard in

accordance with IEC 62061 and

DIN EN ISO 13849-1, category 4,

PL e

► OSSD output reports status to

control unit

► Restart: manual or using

autostart

UR20-PF-O-2DI-SIL

► Connection for two emergency

stop circuit

► SIL 3 safety standard in

accordance with IEC 62061 and

DIN EN ISO 13849-1, category 4,

PL e

► OSSD output reports status to

control unit

► Restart: manual or using

autostart

UR20-PF-O-2DI-DELAY-SIL

► Connection for two emergency

stop circuit

► SIL 3 safety standard in

accordance with IEC 62061 and

DIN EN ISO 13849-1, category 4,

PL e

► OSSD output reports status to

control unit

► Restart: manual or using

autostart

► Switch-off after adjustable

delay

More Performance. Simplified.

u-remote.

Page 14: More Performance. Simplified. u-remote. · 2020. 8. 13. · Simplified. u-remote. In 2017: Our features - your benefit 8 fieldbus gateways Flexible migration of I/Os to your target

u-remote IP67 – system presentation

Page 15: More Performance. Simplified. u-remote. · 2020. 8. 13. · Simplified. u-remote. In 2017: Our features - your benefit 8 fieldbus gateways Flexible migration of I/Os to your target

Two sizes – 30 or 60 mm

Fitting to challenging installation

conditions

Multiprotocol

One module – three protocols

Two types of power feed available- 7/8” and M12 (L-coded)

Free choice of supply concept with up to 16 A

More Performance. Simplified.

u-remote.

Our features - your benefit

Page 16: More Performance. Simplified. u-remote. · 2020. 8. 13. · Simplified. u-remote. In 2017: Our features - your benefit 8 fieldbus gateways Flexible migration of I/Os to your target

More Performance. Simplified.

u-remote.

Fully pottet zinc-die cast housings

Robust but still leight-weight

Integrated Web-Server

Improved comissioning and diagnosis

Our features - your benefit

Accessories included

Simplified ordering and comissioning

Temperature range from -20 to +70°C

Reliable also in harsh environment

Page 17: More Performance. Simplified. u-remote. · 2020. 8. 13. · Simplified. u-remote. In 2017: Our features - your benefit 8 fieldbus gateways Flexible migration of I/Os to your target

Profibus modules with plastic or

metal housing

Fitting to any boundary condition

More Performance. Simplified.

u-remote.

Our features - your benefit

IO-Link integrated

4 x Type A / 4 x Type B over Profinet

16 DI, 16 DO, 16 DIO or 8 DI/DO

Optimal use of size for highest I/O density

SAI active universal

Fieldbus-independant subbus modules for

integration into IP20 remote IO stations

Page 18: More Performance. Simplified. u-remote. · 2020. 8. 13. · Simplified. u-remote. In 2017: Our features - your benefit 8 fieldbus gateways Flexible migration of I/Os to your target

u-remote – portfolio, product news and roadmap

Page 19: More Performance. Simplified. u-remote. · 2020. 8. 13. · Simplified. u-remote. In 2017: Our features - your benefit 8 fieldbus gateways Flexible migration of I/Os to your target

u-remote – releases

More Performance. Simplified.

u-remote.

Stepper motor module incl.

Configurator2489830000 UR20-1SM-50W-6DI2DO-P

8-channel RTD module2555940000 UR20-8AI-RTD-DIAG-2W

Universal digital IO-Module 8DIO

2456530000 UR20-8DIO-P-3W-DIAG

UR67 multiprotocol 16DIO

(PN, EIP, EC)2512830000 UR67-MP-78-16DIO-12-60M

2512840000 UR67-MP-HP-16DIO-12-60M

Galvanic isolated 8 DI module2457240000 UR20-8DI-ISO-2W

Page 20: More Performance. Simplified. u-remote. · 2020. 8. 13. · Simplified. u-remote. In 2017: Our features - your benefit 8 fieldbus gateways Flexible migration of I/Os to your target

u-remote – releases

More Performance. Simplified.

u-remote.

Configuration tool for IO-Link

(EIP, PL, CAN, DN, MOD)www.weidmueller.com

UR67 modules with PushPull

connector (CU)2599680000 UR67-PN-V14-CU-16DI-12

2599670000 UR67-PN-V14-CU-8DIDO-12

Page 21: More Performance. Simplified. u-remote. · 2020. 8. 13. · Simplified. u-remote. In 2017: Our features - your benefit 8 fieldbus gateways Flexible migration of I/Os to your target

4 Channel Hart Master Module

4 AI with channel diagnosis

0…20 mA / 4…20 mA / 4…20 mA

HART modes per channel

- P2P: single connection to 1 HART device

- Multi-drop: current loop with up to 5 HART

devices

Communication DTMs for Modbus-TCP

coupler and HART master module

u-remote – news

More Performance. Simplified.

u-remote.

Page 22: More Performance. Simplified. u-remote. · 2020. 8. 13. · Simplified. u-remote. In 2017: Our features - your benefit 8 fieldbus gateways Flexible migration of I/Os to your target

u-remote – news

ECO coupler Profinet, ModbusTCP, EtherCAT

Main different features to existing couplers- power supply only one path with 10A

- No USB, webserver only via Ethernet

- Max. 16 modules

- Only CE / UL and duty relevant listings

- Temperature range 0…50 C°

- Reduced fieldbus specification• PROFInet: only RT, no IRT; no option handling

• EtherCAT: without distributed clocks

(Support of FSoE modules in Q3 2020)

• Modbus: without Dual LAN

More Performance. Simplified.

u-remote.

Page 23: More Performance. Simplified. u-remote. · 2020. 8. 13. · Simplified. u-remote. In 2017: Our features - your benefit 8 fieldbus gateways Flexible migration of I/Os to your target

CC-Link serial fieldbus coupler

Compatible to main CC-Link master

Same technical features like

DeviceNet

CC-Link is the serial fieldbus protocol

with the second largest market share

worldwide (HMS Industrial Networks, 2019)

More Performance. Simplified.

u-remote.

u-remote – news

UR67 modules with PushPull

connector (POF)

PROFINET Fast Start Up (FSU)

function

PushPull connectors for power and

data (POF)

Integrated web server simplifies

commissioning and troubleshooting

2 galvanically isolated power path

for DI / DO

Page 24: More Performance. Simplified. u-remote. · 2020. 8. 13. · Simplified. u-remote. In 2017: Our features - your benefit 8 fieldbus gateways Flexible migration of I/Os to your target

More Performance. Simplified.

u-remote.

►The fail safe I/O modules allow the comminucation via the safety protocols PROFIsafe

resp. Fail-Safe-over-EtherCAT (FSoE) with a superior safety PLC (Black-Channel)

►Developed for more complex and decentralized safety architectures the fail safe I/O

modules are perfect for remote but flexible solutions

►The logical connection of safe in- and outputs allows maximal flexibility and efficiency

with minimized installation- and maintance effort for modular applications

u-remote - solutions for decentralized safety architectures

Fieldbus + safety protocol

Fail safe

I/O-Modules

Safety PLC

Emergency stop Motor Light

curtain

Motor

contactor

Page 25: More Performance. Simplified. u-remote. · 2020. 8. 13. · Simplified. u-remote. In 2017: Our features - your benefit 8 fieldbus gateways Flexible migration of I/Os to your target

More Performance. Simplified.

u-remote.

Safety PLC

u-remote - solutions for decentralized safety architectures

Page 26: More Performance. Simplified. u-remote. · 2020. 8. 13. · Simplified. u-remote. In 2017: Our features - your benefit 8 fieldbus gateways Flexible migration of I/Os to your target

u-remote - solutions for decentralized safety architectures

UR20- 4DI-4DO-PN-FSxx-V2

➢ 4 digital inputs and 4 digital outputs

➢ 2 inputs and 2 outputs parametrizable as p- or n-

switching

UR20-8DI-PN-FS xx-V2

➢ 8 digital inputs

➢ 4 inputs parametrizable as p- or n-switching

More Performance. Simplified.

u-remote.

➢ For Profisafe or FSoE

➢ SIL 3 safety standard in accordance with IEC 62061 and DIN EN ISO 13849-1, category 4, PL e

➢ Test pulses can be enabled for the inputs

➢ Test pulses can be switched off for capacitive loads

➢ Parametrizable input testing

➢ Equivalent/Anticoincidence input switching

➢ Free parametrizable discrepancy time for 2-channel input switching (5…30000 ms)

Page 27: More Performance. Simplified. u-remote. · 2020. 8. 13. · Simplified. u-remote. In 2017: Our features - your benefit 8 fieldbus gateways Flexible migration of I/Os to your target

Discrete safety solutions without safety PLC Solution for decentralized safety architectures

Fieldbus

Sicheres

Einspeisemodul

Safety Powerfeed

module

More Performance. Simplified.

u-remote.

u-remote - integrated safety for the plant automation

Fieldbus + safety protocol

Fail safe

I/O-Modules

Safety PLC

Emergency stop Motor Light

curtain

Motor

contactor

Page 28: More Performance. Simplified. u-remote. · 2020. 8. 13. · Simplified. u-remote. In 2017: Our features - your benefit 8 fieldbus gateways Flexible migration of I/Os to your target

More Performance. Simplified.

u-remote.