mp1700 install manual en
TRANSCRIPT
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 1 of 49
MP1700E Series Routers
Installation Manual V1.4
Maipu Communication Technology Co., Ltd No. 16, Jiuxing Avenue Hi-tech Park Chengdu, Sichuan Province People’s Republic of China - 610041 Tel: (86) 28-85148850, 85148041 Fax: (86) 28-85148948 URL: http:// www.maipu.com Email: [email protected]
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 2 of 49
All rights reserved. Printed in the People’s Republic of China. No part of this document may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise without the prior written consent of Maipu Communication Technology Co., Ltd. Maipu makes no representations or warranties with respect to this document contents and specifically disclaims any implied warranties of merchantability or fitness for any specific purpose. Further, Maipu reserves the right to revise this document and to make changes from time to time in its content without being obligated to notify any person of such revisions or changes. Maipu values and appreciates comments you may have concerning our products or this document. Please address comments to: Maipu Communication Technology Co., Ltd No. 16, Jiuxing Avenue Hi-tech Park Chengdu, Sichuan Province People’s Republic of China - 610041 Tel: (86) 28-85148850, 85148041 Fax: (86) 28-85148948 URL: http:// www.maipu.com Email: [email protected] All other products or services mentioned herein may be registered trademarks, trademarks, or service marks of their respective manufacturers, companies, or organizations.
Document History
Date Revision No. Description
20/09/2007 R1.0 The MP1700E Series Installation Manual V1.4 provides information about the installation of routers designed and developed by Maipu Communication Technology Co., Ltd
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 3 of 49
Maipu Feedback Form Your opinion helps us improve the quality of our product documentation
and offer better services. Please fax your comments and suggestions to
(86) 28-85148948, 85148139 or email to [email protected].
Document Title MP1700E SERIES INSTALLATION MANUAL V1.4
Product Version
Document Revision Number
1.0
Presentation: (Introductions, procedures, illustrations, completeness, arrangement, appearance)
Good Fair Average Poor
Accessibility: (Contents, index, headings, numbering)
Good Fair Average Poor
Evaluate this document
Editorial: (Language, vocabulary, readability, clarity, technical accuracy, content)
Good Fair Average Poor
Your suggestions to improve the document
Please check suggestions to improve this document: Improve introduction Make more concise Improve Contents Add more step-by-step procedures/tutorials Improve arrangement Add more technical information Include images Make it less technical Add more detail Improve index
If you wish to be contacted, complete the following:
Name Company
Postcode Address
Telephone Email
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 4 of 49
Contents
Installation Manual ....................................................................................7
Purpose .................................................................................................................7
How to Get in Touch ...............................................................................................7
Customer Support...................................................................................................................7
Documentation Support...........................................................................................................7
Overview.....................................................................................................8
Product Features........................................................................................9
Hardware Features.................................................................................. 11
MP1700E Router Appearance.................................................................................11
MP1700E Front Panel ............................................................................................11
MP1700E Back Panel.............................................................................................13
MP1700E System .................................................................................................14
Product Functions .................................................................................................15
MP1700E Main Board ............................................................................................17
Modules.................................................................................................... 19
Sync/Async Serial Interface Module (SAE) Series.....................................................19
1-port High-speed V.24/V.35 Serial Module (1SAE).................................................................19
1SAE Interface Module ..........................................................................................................20
1SAE interface module connected cable..................................................................................20
1SAE Interface Attributes.......................................................................................................20
Channelized E1 Module (CE1) Series ......................................................................21
1-port channelized E1 Module (1CE1).....................................................................................21
1CE1 Interface & Indicator.....................................................................................................21
1CE1 Interface Module Connected Cable ................................................................................21
Non-channelized E1 Series ....................................................................................22
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 5 of 49
1-port Non-channelized E1 (1E1) ...........................................................................................22
Frequency-band MODEM M336 Series ....................................................................23
1-port 33.6K Frequency-band MODEM (1M336) .....................................................................23
Base-band MODEM (M128) Series..........................................................................25
1-port 128K Base-band MODEM (1M128)...............................................................................25
ISDN (U) Series....................................................................................................26
1-port ISDN U Module (1U)....................................................................................................26
IP Module (VOP/VOS) Series..................................................................................28
1-port VoIP Module (1VOP)....................................................................................................28
2-port VoIP Module (2VOP)....................................................................................................29
1-port Switch VoIP Module (1VOS).........................................................................................30
2-port Switch VoIP Module (2VOS).........................................................................................31
Ethernet Module (ETE) Series ................................................................................33
1-port Ethernet Module (1ETE) ..............................................................................................33
ISDN S/T Module (ST) Series.................................................................................34
1-port ISDN S/T Module (1ST)...............................................................................................34
System Installation................................................................................. 35
Preparation ..........................................................................................................35
Environment Requirements....................................................................................................35
Check Router & Accessories...................................................................................................36
Chassis Installation ...............................................................................................37
Tools & Equipment ................................................................................................................37
Machine Installation...............................................................................................................38
Connecting Power Supply ......................................................................................................38
Main Control Board Cable Connection.....................................................................................39
Console Port Connection........................................................................................................39
Grounding Wire Connection ...................................................................................................39
Module Installation ................................................................................................................40
Rack/Desk ............................................................................................................................40
Panel Wire Connection...........................................................................................................40
Hardware Installation ............................................................................................................41
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 6 of 49
Module Interface Cable Connection ........................................................................42
1SA Module Cable Connection................................................................................................42
1CE1/1E1 Module Cable Connection.......................................................................................44
1M336 Module Cable Connection............................................................................................44
1M128 Module Interface Cable Connection .............................................................................45
1U Module Interface Cable Connection ...................................................................................45
1VOP/2VOP Module Cable Connection....................................................................................45
1VOS/2VOS Module Cable Connection....................................................................................45
1ETE Module Cable Connection ..............................................................................................46
1ST Module Cable Connection................................................................................................46
Interface Cable Signal............................................................................. 47
Ethernet Interface Cable........................................................................................47
Console Port Cable................................................................................................48
RM2-1E1 & RM2-1CE1 Uses RJ45-RJ45 Cross-cable.................................................49
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 7 of 49
Installation Manual
Purpose The MP1700E Series Installation Manual V1.4 provides technical
information to understand the installation issues of the routers. The
document provides right answers to your technical queries.
How to Get in Touch The following sections provide information on how to obtain support for
the Maipu English documentation and products.
Customer Support If you have problems or questions regarding your product, please contact
us by e-mail at [email protected]. You can also call our International
Business Department over +86–28-85148850, 85148041, 85148050,
85148750, and 85148997.
Documentation Support Maipu Communication Technology Co., Ltd welcomes comments and
suggestions on the document usefulness. For further queries or
suggestions, contact us by e-mail [email protected] or fax comments
to +86-28-85148948. You can visit our website at http://www.maipu.com,
which comprises interesting subjects such as product knowledge base,
sales & support, and the Maipu news.
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 8 of 49
Overview
MP1700E router is highly beneficial for finance, telecom, tax, and public
security industries and large & medium enterprises. The routers provide a
series of highly efficient and low cost network interconnection solution for
integration and powerful functions.
The router supports:
Internet connection
Multi-service data integration
Branch dialup & backup service
Internet & Extranet access
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 9 of 49
Product Features
High performance & reliability – The MP1700E series router’ CPU
provides high performance and RISC communication processor. The
software adapts high performance and reliable RTOS and network
program design. High port integration - The MP1700E series router has two fixed
10/100M fast Ethernet ports, one high-speed asynchronous interface
(1SAE), and voice card and MIM slots. It has powerful multi-port
access performance, which provides high price-performance ratio
network solution.
Modular system structure - The MP1700E series router adapts
modular system, which provides different interface configuration. They
support various optional interface modules and interface cards, and
customers choose different extending interfaces and modules such as
Ethernet interface, sync/async interface, asynchronous interface,
E1/CE1 interface, ISDN-U IST interface, baseband MODEM, frequency
band MODEM and VOP/VOS interface. They also support the site
upgrade of all core software and modular components.
Routing/transmission integration - The MP1700E series router
integrates CSU/DSU, sync 33.6K MODEM, asynchronous 33.6K MODEM,
ISDN NT1 and ISDN TE into router to provide required solutions.
Universality - The MP1700E series router supports a series of Internet
protocol standard (RFC) and international communication network
standard.
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 10 of 49
Structure - The hardware design adapts lower power consumption
design and integrated structure design, which has powerful
performance on radiation and EMC.
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 11 of 49
Hardware Features
MP1700E Router Appearance
MP1700E router
MP1700E Front Panel
MP1700E front panel
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 12 of 49
Indicators from left to right:
SYS & PWR (system and power supply indicator)
SYS - System status indicator. It shines fast when system is loading, and
after that it shines slowly
PWR - System power supply indicator, and it is on after power on.
SLOT1 (slot 1 status indicator)
ACT - voice card module data indicator
RDY - voice card module link status indicator
SLOT 0 (slot 0 status indicator)
ACT - inserted module data indicator
RDY - inserted module link status indicator
SA (fixed sync/async serial status indicator)
ACT - sync/async serial data indicator
LINK - sync/async serial link status indicator
CONSOLE (console port)
TXD - console port data sending indicator
RXD - console port data receiving indicator
ETHERNET1 (Ethernet interface1)
100M - 10/100M Ethernet interface data rate indicator. On: 100M,off:
10M
ACT - Ethernet interface data indicator
ETHERNET0 (Ethernet interface 0)
100M - 10/100M Ethernet interface data rate indicator. On: 100M/off: 10M
ACT - Ethernet interface data indicator
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 13 of 49
MP1700E Back Panel
MP1700E back panel interface configuration
MP1700E back panel interface:
Interface Form Description Application
ON/OFF Power supply switch, right is OFF; left is ON
INPUT AC 100-240V 1A input
SLOT1 Bus slot VOP/VOS module
SLOT0 Decided by interface module
High-speed serial, bus slot
MIM module
S/A DB25 pin High-speed serial High-speed fixed sync/async interface
SLOT1 is voice card module slot for VOP/VOS series module; SLOT0 is MIM
slot, adopting modularization design, and its function can be realized
according to different interface card and relevant software modules.
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 14 of 49
MP1700E System MP1700E router basic configuration and working environment:
Item Description
Console port One fixed, async DTE working mode (RJ45)
Ethernet interface Two fixed 10/100Mbps fast Ethernet (RJ45)
SA interface One fixed high-speed async/sync interface (DB25)
Voice card slot One voice card SLOT1
MIM slot MIM SLOT0, supports various modules
Processor High performance PowerPC processor
FLASH 8MB
SDRAM 64MB
Dimension (W×D×H)
340×230×44 (mm)
Power supply input voltage
AC: 100 – 240V 50/60HzDC: -40~-57V - only MP1700E supports. AC/DC.
Environment Temperature
0-40℃
Environment humidity
10-90%. Non-condensing
Power supply rating power
45W
Maximum power consumption
15W
MP1700E router doesn’t have asynchronous interfaces with modular and
clip design.
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 15 of 49
Product Functions MP1700E functions, supported protocols & services:
Supported protocols & Services
Description
Network protocol WAN supports: PPP PPP compression SLIP CSLIP Frame relay Frame relay switching X.25 X.25 switching HDLC LAPB ISDN LAN is Ethernet network, and it supports two kinds of link layer frame format: Ethernet-II Ethernet-SNAP
Dialup network MODEM dialup(call in/call out)
CALLBACK Dialup on demand Dialup backup
Routing protocol Static routing Dynamic routing: RIPv1 RIPv2 OSPF BGP IRMP (compatible with CISCO EIGRP protocol) SNSP (compatible with CISCO ODR protocol) Dial-on-demand routing (DDR) Policy routing Multicast: IGMP PIM-SM PIM-DM
DVMRP Hot backup: VRRP VBRP (compatible with CISCO HSRP protocol)
Network service ARP
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 16 of 49
Proxy ARP L2TP Configuration command protection IP packet filtering firewall IP UNNUMBERED IP policy routing DHCP relay PAP/CHAP check EASY IP NAT network concealing RADIUS check IPSEC data encryption IKE GRE Load balance MPLS
QoS service PQ CQ WFQ CBWFQ LLQ WRED CAR
Network management SNMPv1, SNMPv2, SNMPv3 Supporting standard network management (fully compatible with CISCO) Configuration via Console port Local or remote login via local Telnet Configuration command security isolation function Chinese/English prompting and help information Debugging information, for troubleshooting. Login and managing other products via Telnet Download and upload configuration file and application program by FTP Download and upload configuration file and application program by TFTP Colorful distributing debugging information Log function
Security IP packet filtering firewall, PAP/CHAP, MD5, NAT, RADIUS, TACACS, IPsec data encryption
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 17 of 49
MP1700E Main Board
The MP1700E main board includes 12/4/4 fixed interface, one voice card
slot, one MIM slot, eight indicators and power supply slots.
Fixed interface
The MP1700E provides fixed console port, Ethernet interface, high-speed
sync/async interface and asynchronous serial, which is totally 12/4/4 fixed
interfaces.
Console port
Console port attributes:
Attributes Description
Converter type RJ45
Interface standard RS232
BR 9600bps - 115200bps
Supported service Connect to character terminal Connect to local PC serial, and operate terminal emulation program command line interface on PC
Ethernet interface
Ethernet interface attributes:
Attributes Description
Converter type RJ45
Interface number 2
Supported frame format Ethernet_II Ethernet_SNAP IEEE 802.2 IEEE 802.3
Working mode 10M/100M adaptive Full/half-duplex Auto across
Supported network protocol IP Novell IPX
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 18 of 49
Fixed high-speed sync/async interface
Fixed high-speed sync/async interface attributes:
Description Attributes
Synchronous Asynchronous
Converter type DB25 DB25
V.24 V.35 Interface standard and working mode DTE
DCE DTE DCE
EIA/TIA-232
Minimum (bps) 1200 1200 300
Maximum (bps) 128K 8M 115.2K
Dialup Backup
Supported protocols & Services
X25 HDLC PPP SLIP FR LAPB
HDLC PPP SLIP
Slot
MP1700E series router has two slots: SLOT0 and SLOT1. SLOT0 is MIM
module slot, and it supports Ethernet interface module, sync/async
interface module, asynchronous interface module, E1/CE1 interface
module, U interface module, ST interface module, baseband MODEM
interface module, frequency band MODEM module, VOP/VOS module. It is
compatible with MP17XX,MP26XX series router function module.
SLOT1 is voice card slot for VOP/VOS card module, which can access any
telephone via dialup or second dialup; you can realize free phone call in
network by IP network.
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 19 of 49
Modules
MP1700E router is modular router and provides two slots. SLOT1 is voice
card slot for VOP and VOS series voice modules. SLOT0 is MIM slot
compatible with all serial interface modules. Supported modules are 1SAE,
1CE1, 1E1, 1M336, 1M128, 1U, 1VOP, 2VOP, 1VOS, 2VOS, 1ETE, 1ST and
8AX.
Sync/Async Serial Interface Module (SAE) Series 1-port High-speed V.24/V.35 Serial Module (1SAE) 1SAE module is applied for MP1700E router, and its main function is to
complete the processing of 1port sync/async serial data flow. For
synchronization, DCE working mode is 2.048Mbps; DTE working mode is
8Mbps.
For Asynchronization, it is 115.2Kbps. The MP1700E router serial interface
default working mode is in synchronous mode. Synchronous serial
interface works in DTE or DCE mode. In DTE mode, it receives external
DCE clock, such as external modem; while in the mode of DCE, router
provides clock. V24/V35 mode switch is through panel.
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 20 of 49
1SAE Interface Module
1-port high-speed V.24/V.35 serial module(1SAE)
1SAE interface module connected cable 1SAE module interface cable is V35 DTE cable and V24 connected DTE
cable.
1SAE Interface Attributes 1SAE module interface attributes:
1-port high-speed V.24/V.35 serial module (1SAE) attributes:
Description Attributes
Sync Async
Tie-in DB25-DB25 DB25-DB25
V.24 V.35 Interface standard and working mode DTE
DCE DTE DCE
EIA/TIA-232
Minimum baud rate (bps) 1200 1200 300
Maximum baud rate (bps) 128K 8M 115.2K
Dialup Backup
Supported protocols & services
X25 HDLC PPP SLIP FR LAPB
HDLC PPP SLIP
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 21 of 49
Channelized E1 Module (CE1) Series 1-port channelized E1 Module (1CE1) 1-port channelized E1 module main function is to provide 1984K multi-
timeslot data flow receiving and sending and processing port. As CE1
interface, it divides slot 1-31 to different groups, and each group timeslot
after binding can be used as one interface.
1CE1 Interface & Indicator 1CE1 interface:
1-port channelized E1 (1CE1)
1-port channelized E1 (1CE1) indicator:
LOS On: Can not check frame sync signal Off: After sync
1CE1 Interface Module Connected Cable 1CE1 and BNC pin coaxial cable and RJ45-RJ45 straight connected twisted-
pair cable.
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 22 of 49
1CE1 Interface Module Attr ibutes
1-port channelized E1 (1CE1) attributes:
Attributes Description
Interface BNC
Interface number 1 group
Interface standard G.703
Supported protocol PPP X.25 HDLC FR
Non-channelized E1 Series 1-port Non-channelized E1 (1E1) 1port non-channelized E1 module provides a data transmission port with
2.048Mbit/s bandwidth. E1 is same as CE1, it can be divided into 32
timeslots, and timeslot 0 of E1 can be used to transmit data in unframed
mode, to realize 2M transparent transmission.
1E1 Interface Module & Indicator
1E1 interface module:
1-port non-channelized E1(1E1)
1-port non-channelized E1(1E1)indicator:
LOS On: transparent 2M transmission; on: non-transparent and cannot check frame synch signal; off: after synch.
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 23 of 49
1E1 Interface Connected Cable
1E1 and BNC pin coaxial cable and RJ45-RJ45 straight connected twisted-
pair cable.
1E1 Interface Attributes
1E1 interface attributes:
1-port non-channelized E1 (1E1) attributes:
Attributes Description
Interface BNC
Interface number 1 group
Interface standard G.703
Supported service X.25 FR
Supported protocol PPP HDLC
Frequency-band MODEM M336 Series 1-port 33.6K Frequency-band MODEM (1M336) 1-port 33.6K frequency-band MODEM is same as out-built or inbuilt
MODEM. Its interface works in the mode of synch or async. It also
supports leased line or dialup line working mode.
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 24 of 49
1M336 Interface Module & DIP Switch
1M336 interface module:
1-port 33.6K frequency-band MODEM (1M336)
DIP switch:
1-port 33.6K frequency-band MODEM (1M336) DIP switch:
DIP switch Mode
1 2
Description
Frequency-band MODEM mode
OFF OFF LINE is used as inbuilt frequency-band MODEM interface.
Console port mode ON OFF LINE is used as CONSOLE port.
1M336 Interface Module Connected Cable
1M336 module connected cable is RJ45 (4, 5 signal line) or RJ11line.
1M336 Module Interface Attr ibutes
1-port 33.6K frequency-band MODEM (1M336) interface:
Attributes Description
Tie-in RJ45
Interface number 1
Supported link protocol
PPP FR X.25 HDLC
Supported network protocol
IP
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 25 of 49
Base-band MODEM (M128) Series 1-port 128K Base-band MODEM (1M128)
1M128 Interface Module, Indicator & DIP
Switch
1M128 interface module:
1-port 128K baseband MODEM (1M128)
Indicator description:
1-port 128K base-band MODEM (1M128) indicator:
ACT On: Link established.
B1 B1 channel indicator LED on: When using channel B1, and rate is 64K
B2 B2 channel indicator LED on: When using channel B2, and the rate is 128K
DIP switch:
1-port 128K baseband MODEM (1M128) DIP switch:
DIP switch Mode
1 2
Description
Loopback ON Reserved
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 26 of 49
1M128 Interface Connected Cable
1M336 module connected cable is RJ45 (4, 5 signal line) or RJ11 telephone
line.
1M128 Interface Attributes
1M128 interface attributes:
1-port 128K base-band MODEM (1M128) interface:
Attributes Description
Tie-in RJ45
Interface number 1
Supported link protocol
PPP ·frame relay ·X.25 ·HDLC
Supported network protocol ·IP
ISDN (U) Series 1-port ISDN U Module (1U) 1port ISDN U module connects DDN network and ISDN network, and not
to connect modem.
1U Module & Indicator
1U module:
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 27 of 49
Indicator description:
1-port ISDN U module (1U) indicator:
ACT The LED on after link established
B1 B1 channel indicator LED on: when using channel B1, and rate is 64K
B2 B2 channel indicator LED on: when using channel B2, and the rate is 128K
1-port ISDN U module (1U) DIP switch:
DIP switch Mode
1 2
Description
Loopback ON Reserved
1U Module Connected Cable
1U module connected cable RJ45 (4, 5 signal line) or RJ11 telephone line.
1U Interface Attributes
1U interface attributes:
1-port ISDN U module (1U) interface attributes:
Attributes Description
Tie-in RJ45
Interface number 1
Supported link protocol
PPP
Supported network protocol
IP
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 28 of 49
IP Module (VOP/VOS) Series 1-port VoIP Module (1VOP) 1-port VoIP module accesses any telephone through IP network; You can
easily realize free phone call through IP network.
1VOP Module Indicator
1VOP interface module:
1-port VoIP module (1VOP)
1-port VoIP module (1VOP) indicator:
V1 VoIP module indicator. The LED is on during the call.
V2 1VOP module may not have this LED, and if it has, the LED will be not on.
1VOP Module Connected Cable
1VOP module connected cable is RJ45 (4, 5 signal line) and RJ11 telephone line.
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 29 of 49
1VOP Interface Attributes
1-port Voice module (1VOP) interface attributes:
Attributes Description
Interface RJ45 jack
Interface number 1
Supported protocol
H.225 H.245 RTP RTCP G.711 G.723 G.729
2-port VoIP Module (2VOP) 2-port VoIP module may access any call in IP network via dialup; you can realize
free phone call via IP network.
2VOP Module & Indicator
2VOP module:
2-port VoIP module (2VOP)
2-port VoIP module (2VOP) indicators:
V1 VoIP module indicator. LED on: after pickup, during the call.
V2 VoIP module indicator. LED on: after pickup, during the call.
2VOP Module Connected Cable
2VOP module connected cable is RJ45 external cable.
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 30 of 49
2VOP Module Interface Attributes
2VOP interface attributes:
2-port VoIP module (2VOP) interface attributes:
Attributes Description
Interface RJ45 jack (two RJ11 plugs)
Interface number
2 (RJ11)
Supported protocol
H.225 H.245 RTP RTCP G.711 G.723 G.729
1-port Switch VoIP Module (1VOS) 1-port switch VoIP module may access any phone in IP network through dialup or
second dialup; you can easily realize free phone call through IP network.
1VOS Module & Indicator
1VOS module:
1-port switch VoIP module (1VOS)
Indicator description:
1-port switch VoIP module (1VOS) indicator:
V1 VoIP module indicator. LED on: During the phone call.
V2 1VOS module may not have this LED. Otherwise, the LED will never be on.
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 31 of 49
1VOS Module Connected Cable
1VOS module connected cable is RJ45 (4, 5 signal line) and RJ11 cable.
1VOS Interface Attributes
1-port switch VoIP module (1VOS) interface attributes:
Attributes Description
Interface RJ45 jack
Interface number 1
Supported protocol
H.225 H.245 RTP RTCP G.711 G.723 G.729
2-port Switch VoIP Module (2VOS) 2-port switch VoIP module access any phone in IP network via dialup or second
dialup; you can easily realize free phone call via IP network.
2VOS Interface Module & Indicator
2VOS interface module:
2-port switch VoIP module (2VOS)
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 32 of 49
Indicator description:
2-port switch VoIP module (2VOS) indicator:
V1 VoIP module indicator. LED on: during the phone call
V2 VoIP module indicator. LED on: during the phone call
2VOS Module Connected Cable
2VOS module connected cable is RJ45 external cable.
2VOS Module Interface Attributes
2-port switch VoIP module (2VOS) interface attributes:
Attributes Description
Interface RJ45 jack
Interface number 2 (RJ11)
Supported protocol H.225 H.245 RTP RTCP G.711 G.723 G.729
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 33 of 49
Ethernet Module (ETE) Series
1-port Ethernet Module (1ETE) 1-port Ethernet module realizes Ethernet connection.
1ETE Module & Indicator
1ETE module:
1-port Ethernet module (1ETE)
1-port switch VoIP module (1ETE) indicator:
LINK On: link connected
Tx LED Blinking: data transmit
Rx LED Blinking: data receive
1ETE Module Connected Cable
RJ45 cable.
1ETE Module Interface Attributes
1ETE module interface attributes:
1-port Ethernet port (1ETE) attributes:
Attributes Description
Tie-in RJ45
Tie-in number 1
Supported protocol 802.3
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 34 of 49
ISDN S/T Module (ST) Series 1-port ISDN S/T Module (1ST) 1port ISDN S/T module.
1ST Module & Indicator
1ST module:
1-port ISDN S/T module (1ST) indicator:
ACT Active indicator, and it is on when it operates normally.
B1 B1 channel indicator. The indicator on when using Channel B1, B1=64K or B1+B2=128K
B2 B2 channel indicator. The indicator on when using Channel B2, B2=64K or B1+B2=128K
1ST Module Connected Cable
1ST cable is RJ45 straight connected Ethernet cable.
1ST Module Interface Attributes
1-port ISDN S/T module (1ST) interface attributes:
Attributes Description
Tie-in RJ45
Number 1
Supported protocol PPP
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 35 of 49
System Installation
Preparation
Read the manual
Place router on a safe flat surface
Do not put heavy material on router
Use UPS
Ensure proper grounding
Environment Requirements
Operat ing Environment
To ensure good working of router, maintain stable temperature and
humidity. Always place router in the equipment room. The environment
requirements are:
Environment temperature: 0~40°C
Humidity: 10~90%. Non-condensing
Around the ventilation, the space should be no less than10cm. We suggest
installing router on 19-inch standard rack.
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 36 of 49
Temperature & Humidi ty
Maintain stable temperature and humidity in the equipment room.
Temperature Relevant humidity
Long-term Short-term Long-term Short-term
15°C ~ 30°C 0 ~ 40℃ °C 40% ~ 65% 0% ~ 90%
Dust- f ree Environment
Dust is harmful for router operation. Dust causes static absorption. Dust
damages the router especially when the temperature and humidity are
lower.
Check Router & Accessories Before installation, check the router and its accessories.
Router Conf igurat ion & Accessor ies Item Name No Description
1 MP1700Echassis 1 Router chassis
2 Power supply cable 1 220V10A
3 Console port cable 1 RJ45-DB9 crossing cable
4 Ethernet cable 2 Straight Connected Ethernet cable
5 Sync/async DTE cable 1 V35 DTE cable (1)
6 Technical documents 1 Installation manual configuration Manual (CD)
7 Installation fittings 1 Feet mat and installation bolt 1 set.
8 Product packaging 1 Including foam anti-shocking material and external packing box, plastic bag etc.
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 37 of 49
Chassis Installation Tools & Equipment Tools:
Screwdriver
Anti-static equipment
Connected cables:
Console port cable
Ethernet cable (MP1700E Ethernet cable is configured according to the
number of Ethernet modules)
Modular interface cable
Equipment:
Ethernet 10 BASE-T HUB
Configuring terminal (can be PC)
Equipment relevant to optional module
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 38 of 49
Machine Installation The dimension of MP1700E is 340mm x 230mm x 44mm(W×D×H)and
its installation process is:
Step 1: Fix angle iron on front panel or back panel sides with bolts
Step 2: Place router on empty slot
Step 3: Fix angle iron to slots with bolts
Step 4: Bracket and fixed angle iron will be fixed on the rack
Connecting Power Supply MP1700E router adapts stable power supply switch system and have
different power supply system.
Input power supply (AC): 100~240V,50/60Hz
Input power supply (DC): -40~-57V only MP1700E supports
Power consumption: 15W±10%
Always use the power supply jack or MIM PC power supply jack. Ensure
reliable grounding.
Ground wire
Live wireNaught wire
Power supply jack
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 39 of 49
Connecting power supply:
Put power supply switch to OFF, and then connect one side of power
supply cable to the entry of back panel of router, and another side to
power supply jack(AC: 220V 50Hz/60Hz, DC: -48V), only MP1700E
supports
Put power supply switch to ON
Check whether the power supply lamp of front panel is on, if not,
please repeat step one and two.
Main Control Board Cable Connection The section explains the method of connecting MP1700E router control
board cable to network including connecting router console port.
Console Port Connection Routers provide one EIA/TIA-232 async serial console port. The user
configures router via the port by adopting RS-232 serial character terminal
(normally a PC).
Step 1: Find a character terminal – a standard terminal with RS-232
serial or normal PC.
Step 2: Ensure that router or terminal is out of power supply and
connect RS-232 serial and console port with cables.
Grounding Wire Connection MP1700E connecting to the ground guarantees of anti-thunder and
malfunctioning of routers. For external network connection, such as E1
interface, PSTN are protected by the grounding cable.
Connect this point and ground by a thick cable, with the resistance no
bigger than 4Ω. If the router is installed on 19-inch standard rack, the
rack should be grounding.
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 40 of 49
Module Installation The routers adapt modular system structure and different kinds of
interface configuration.
Module installation steps:
Step 1: Choose the module and interface.
Step 2: Inset the module to slot. Insert the module circuit board into
interface card slot.
Step 3: Push in the module close to back panel.
Step 4: Tighten the screw.
Rack/Desk Installing routers to 19-inch standard rack:
Front-end installation method:
Step 1: Install ear bracket to both sides of front-end of MP1700E and
fix with screw.
Step 2: Place router on standard rack and connect bracket and metal
frame with screw.
Panel Wire Connection Panel wire connection includes Ethernet interface cable, WAN sync/async
cable connection.
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 41 of 49
Hardware Installation
Complete machine installation according to the details, and make sure
the power supply switch is OFF
Connect one side of AC power supply cable to router power supply, and
another side to power supply jack
Configure the router through console port after first power on
Insert one side of configuration cable to console port, and another side
to PC or terminal serial
Insert one side of Ethernet cable to LAN interface, and another side to
LAN
Connect sync/async communication cable to router WAN Interface
MP1700E sync/async interface can work in the mode of V.24/V.35, and
these two modes are completed by V.24/V.35 button
In V.24 mode, interface adopts standard RS232 cable connection
In V.35 mode, interface adopts special V.35DTE cable
V.24/V.35 cable
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 42 of 49
Module Interface Cable Connection 1SA Module Cable Connection Before connecting sync/async serial, ensure the following two points:
Equipment type: The equipment type connecting sync/async serial,
which is sync/async or DTE/DCE. Access equipment requires signal
standard, baud rate and sync clock.
DTE/DCE: Sync/async serial accesses external Modem or TA (terminal
adapter) as dialup interface. Sync serial has two modes - DTE and DCE.
Router is used as DTE equipment.
DTE and DCE equipment:
Equipment type Interface type Equipment
DTE Pin type PC Router
DCE Hole type MODEM Multiplexer CSU/DSU
Rate and transmission distance: Sync/async serial supports
different signal standards and baud rates in different working modes.
Choose cables as per prevailing conditions.
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 43 of 49
V.24 cable rate and transmission distance:
Baud rate (bps) Maximum transmission distance (m)
2400 60
4800 60
9600 30
19200 30
38400 20
64000 20
115200 10
V.35 cable rate and transmission distance:
Baud rate (bps) Maximum transmission distance (m)
2400 1250
4800 625
9600 312
19200 156
38400 78
56000 60
64000 50
2048000 30
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 44 of 49
1SAE Module Cable Connect ion
Step 1: Insert one side of DB-25 to 1SAE module DB-25 interface and
screw down fixed knob.
Step 2: Connect another DB25 interface to V.24-V.35 (DB-25, M-34)
cable and then connect the following equipment:
- If WAN is DDN line, connect (V.35 cable) to digital Modem V.35
interface.
- If WAN is dialup line, connect (V.24 cable) to analog Modem serial.
Step 3: After power on, check indicator status on 1SA module panel.
- DCD on: Link connected
1CE1/1E1 Module Cable Connection
Step 1: Connect one side of BNC plug to BNC interface of 1CE1/E1
module. Connect another side to equipment. Connect TX to RX
equipment. Connect RX TX line.
Step 2: After power on, check LOS status of 1CE1/E1 module.
Indicator on means malfunction and signal loses sync. Then check the
line.
1M336 Module Cable Connection Insert RJ11 plug of 1M336 module cable to LINE jack.
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 45 of 49
1M128 Module Interface Cable Connection Step 1: Insert RJ11 plug of 1M128 module cable to LINE jack.
Step 2: After power on, please check ACT status of 1M128 interface
module. If the indicator is off, please check the line.
1U Module Interface Cable Connection Step 1: Insert RJ11 plug of 1U module cable to external line;
Step 2: After power on, please check ACT status of 1M128 interface
module. If the indicator is off, please check the line.
1VOP/2VOP Module Cable Connection Connect VOP module cable according to the following steps:
Step 1: insert telephone line to RJ11/RJ45 interface of 1VOP/2VOP,
and another side to telephone.
Step 2: when having the phone call, pay attention to the indicator of
1VOP/2VOP card back panel: the indicator and Active LED should be on.
1VOS/2VOS Module Cable Connection Connect VOS module cable according to the following steps:
Step 1: Insert telephone line to RJ11/RJ45 interface of 1VOS/2VOS,
and another side to small switch or external junction box.
Step 2: When having the phone call, pay attention to the indicator of
1VOS/2VOS card back panel: the indicator and Active LED should be
on.
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 46 of 49
1ETE Module Cable Connection Please connect 1ETE module cable according to following steps:
Step 01: Insert one end of RJ45 cable into 1ETE module to the jack
Step 02: Connect another end of RJ45 to relevant equipment line
1ST Module Cable Connection Connect 1ST module cable according to following steps:
Step 01: Insert one end of RJ45 cable into 1ST module
Step 02: Connect another end of RJ45 to relevant equipment line
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 47 of 49
Interface Cable Signal
Ethernet Interface Cable MP1700E router Ethernet interface cable is 8-pin unshielded twisted-pair.
Pin 1,2 is transmit and pin 3,6 is receive. They can be connected with HUB.
RJ45 Signal Direction RJ45 Length 1 TX+ —> 1 2 TX- —> 2 3 RX+ <— 3 6 RX- <— 6 4 --- --- 4 5 --- --- 5 7 --- --- 7 8 --- --- 8
2m
RJ45 cross cable (type-5 twisted-pair) pin configuration
RJ45 Signal Direction RJ45 Length 1 TX+ —> 3 2 TX- —> 6 3 RX+ <— 1 6 RX- <— 2 4 --- --- 7 5 --- --- 8 7 --- --- 4 8 --- --- 5
2m
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 48 of 49
Console Port Cable MP1700E router console port cable is connected with . One side RJ45 plug and the
other is DB9 female.
RJ45 jack standard DB9 interface
CONSOLE PORT CABLE PIN CONFIGURATION
RJ45 Signal Direction DB9 Length
1 CTS —> 8
2 DSR —> 6
3 RXD —> 2
4 GND --- 5
5 --- --- ---
6 TXD <— 3
7 DTR <— 4
8 RTS <— 7
--- --- 1
--- --- 9
3m
5 4 3 2 1
9 8 7 6
MP1700E Series Installation Manual V1.4
Maipu Confidential & Proprietary Information Page 49 of 49
RM2-1E1 & RM2-1CE1 Uses RJ45-RJ45 Cross-cable
PIN CONFIGURATION FOR RJ-45 CROSS-CABLE
RJ45 Signal Direction RJ45
1 RX+ <— 4
2 RX- <— 5
3 --- --- 7
6 --- --- 8
4 TX+ —> 1
5 TX- —> 2
7 --- --- 3
8 --- --- 6