msw fired indirect combined cycle plant: a novel solution...

26
Dr. Sudip Ghosh Associate Professor Department of Mechanical Engineering Indian Institute of Engineering Science and Technology, Shibpur Howrah -711103, West Bengal, India 1 MSW fired indirect combined cycle plant: A novel soluon to waste management and power for India

Upload: others

Post on 26-Jun-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MSW fired indirect combined cycle plant: A novel solution ...uest.ntua.gr/heraklion2019/proceedings/Presentation/3. S. GHOSH.pdf · The study confirms that, such kind of small scale

Dr. Sudip Ghosh

Associate ProfessorDepartment of Mechanical Engineering

Indian Institute of Engineering Science and Technology, ShibpurHowrah -711103, West Bengal, India

1

MSW fired indirect combined cycle plant: A novel solution to waste management and power for India

Page 2: MSW fired indirect combined cycle plant: A novel solution ...uest.ntua.gr/heraklion2019/proceedings/Presentation/3. S. GHOSH.pdf · The study confirms that, such kind of small scale

”A world in transformation”

2

”The boom years for coal are over ” – World Energy Outlook 2017

We are on a hurried path of changes

Large-scale shifts in the global energy system :

- Rapid deployment of clean energy technologies- Falling cost of renewables- Solar, Wind, Hydro and Biomass lead the RE campaign

”Global energy demand is 30% higher by 2040”– WEO 2017

IIEST/SG

Page 3: MSW fired indirect combined cycle plant: A novel solution ...uest.ntua.gr/heraklion2019/proceedings/Presentation/3. S. GHOSH.pdf · The study confirms that, such kind of small scale

Issues with Renewables

3

No uniform formula to decide right energy mix

Diverse sources: Sun, air, water, biomass, geothermal

Equally diverse technologies for energy conversion

Varied resource mix at country or region levels

Different levels of development and maturation

Most technologies at low conversion efficiency

Not yet fit to cater to base load continuous generation

Technologies have different carbon emission implications

IIEST/SG

Page 4: MSW fired indirect combined cycle plant: A novel solution ...uest.ntua.gr/heraklion2019/proceedings/Presentation/3. S. GHOSH.pdf · The study confirms that, such kind of small scale

Waste Conversion: Clean-Tech!

4IIEST/SG

Waste conversion fits in well as a competing clean technology

Traditional biomass conversion technologies like combustion and gasification, also apply to MSW. Besides that, MSW conversion has inherent disposal solution

Municipal Soloid Waste (MSW) is considered as local sources for a city or municipal area (self-sustaining too, in the sense that city keeps on generating resources on daily basis, generation volume predictable )

Page 5: MSW fired indirect combined cycle plant: A novel solution ...uest.ntua.gr/heraklion2019/proceedings/Presentation/3. S. GHOSH.pdf · The study confirms that, such kind of small scale

Present work

5IIEST/SG

Here we present the configuration, thermal design and analysis of a combined cycle plant, fuelled by segregated municipal solid waste (MSW).

Energy, exergy and environmental (3-E) analysis along with optimization study of the plant is carried out and reported.

Page 6: MSW fired indirect combined cycle plant: A novel solution ...uest.ntua.gr/heraklion2019/proceedings/Presentation/3. S. GHOSH.pdf · The study confirms that, such kind of small scale

Present work

6IIEST/SG

We took the city named Chandanagar (22.87°N, 88.38°E), a highly populated municipal area, located near Kolkata and governed by a municipal corporation, as the case study.

As per the report of the Chandanagar Corporation, about 46 tonnes of raw waste is generated on a daily basis (2017-2018)

Page 7: MSW fired indirect combined cycle plant: A novel solution ...uest.ntua.gr/heraklion2019/proceedings/Presentation/3. S. GHOSH.pdf · The study confirms that, such kind of small scale

Waste disposal

7IIEST/SG

Page 8: MSW fired indirect combined cycle plant: A novel solution ...uest.ntua.gr/heraklion2019/proceedings/Presentation/3. S. GHOSH.pdf · The study confirms that, such kind of small scale

MSW Analysis

8IIEST/SG

Proximate Analysis

Ultimate Analysis

LHV theoretical

LHV actual

C: 40-50 %H: 5.5-6.6 %O: 30-35 %N: 0.6-1.2 %S: 0.1-0.5 %Cl: 0.9-1.7 %Ash- Rest

Volatile matter: 50-80 %Fixed carbon: 10-18 %Ash: 6-12 %Heavy metalsCd:1 %Cr: <10 %Hg: 0.002%Pb: 39%As: <1%Se: <0.005%

14668.77 (kJ/kg)

13566.7 (kJ/kg)

Page 9: MSW fired indirect combined cycle plant: A novel solution ...uest.ntua.gr/heraklion2019/proceedings/Presentation/3. S. GHOSH.pdf · The study confirms that, such kind of small scale

9IIEST/SG

Gasification: A versatile route

Page 10: MSW fired indirect combined cycle plant: A novel solution ...uest.ntua.gr/heraklion2019/proceedings/Presentation/3. S. GHOSH.pdf · The study confirms that, such kind of small scale

Gasification

10IIEST/SG

A thermo-chemical process in which solid biomass is partially oxidized to yield combustible producer gas.

Major components of producer gas: CH4, H2, CO, CO2, H2O and N2.

LHV of Producer gas 4-6 MJ/N m3 (gasifying agent Air)

LHV of Producer gas 12-18 MJ/N m3 (gasifying agent Steam/Oxygen)

Page 11: MSW fired indirect combined cycle plant: A novel solution ...uest.ntua.gr/heraklion2019/proceedings/Presentation/3. S. GHOSH.pdf · The study confirms that, such kind of small scale

11IIEST/SG

Gasifier-Gas Engine: A popular generation option

Page 12: MSW fired indirect combined cycle plant: A novel solution ...uest.ntua.gr/heraklion2019/proceedings/Presentation/3. S. GHOSH.pdf · The study confirms that, such kind of small scale

Disturbing Issues

12IIEST/SG

Low Overall efficiency (16-20%).

Extensive gas cleaning and cooling requirement.

High cost of operation and maintenance.

Page 13: MSW fired indirect combined cycle plant: A novel solution ...uest.ntua.gr/heraklion2019/proceedings/Presentation/3. S. GHOSH.pdf · The study confirms that, such kind of small scale

Gas Cleaning

13IIEST/SG

Page 14: MSW fired indirect combined cycle plant: A novel solution ...uest.ntua.gr/heraklion2019/proceedings/Presentation/3. S. GHOSH.pdf · The study confirms that, such kind of small scale

Cleaning needs for ICE/GT

14IIEST/SG

Impurities Unit IC Engines Gas Turbines

Particulates (size)

mg/Nm3(µm)

<50(<10)

<30(<5)

Tars mg/Nm3 <100 <10.0-

Alkali metals mg/Nm3 <0.1 <0.1

N species ppm(v) - <50S species ppm(v) <20 <20

Halides ppm(v) - <1

Page 15: MSW fired indirect combined cycle plant: A novel solution ...uest.ntua.gr/heraklion2019/proceedings/Presentation/3. S. GHOSH.pdf · The study confirms that, such kind of small scale

Replace Fired Engine/GT with indirect Heating

15IIEST/SG

No need of gas cooling & cleaning

No corrosion and erosion , particulate deposition : GT safe

Clean GT exhaust; recyclable

No fired GT

Operates on low-cost and dirt fuels

Combustor Heat

Exchanger

Page 16: MSW fired indirect combined cycle plant: A novel solution ...uest.ntua.gr/heraklion2019/proceedings/Presentation/3. S. GHOSH.pdf · The study confirms that, such kind of small scale

Externally Fired Combined Cycle

16IIEST/SG

Segregated materials

Waste

SEG

CC

AT

HP

ST

SUP

EVAP

ECO

P

COND

HRSG

Stack

C1

AF

RH

LP

ST

HX

C2

Page 17: MSW fired indirect combined cycle plant: A novel solution ...uest.ntua.gr/heraklion2019/proceedings/Presentation/3. S. GHOSH.pdf · The study confirms that, such kind of small scale

MSW Combined Cycle: Model

17IIEST/SG

31211 .})(){( genCgenPLPSTHPSTgenCGTnet WWWWWWW

Net power output from the plant is calculated as

Annualized electricity delivered (MWeh) by the plant is

determined as

1000/)1.(8760.. networkondistributinetannual LCUFWP

CUF represents Capital Utilization Factor (taken as 0.5, as the plant operating hour is 12 h a day basis)

Overall electrical efficiency of the plant is calculated as

wastewaste

netoverall LHVm

W.

Page 18: MSW fired indirect combined cycle plant: A novel solution ...uest.ntua.gr/heraklion2019/proceedings/Presentation/3. S. GHOSH.pdf · The study confirms that, such kind of small scale

MSW Combined Cycle: Model

18IIEST/SG

Exergetic efficiency of the plant as well for the plant components is calculated as:

Environmental performance of the plant is evaluated via determining the specific CO2 emission as well as the sustainability index (SI).

The specific fuel exergy is given by

fuel

productex Ex

Ex

wastewaste LHVEx .)/.(4124.01

)/.0531.01).(/(34493.0)/(016.0044.1

CO

CHCOCH

net

COCO W

..N 3600442

2

)(SI

plant,exergetic

1

1

Page 19: MSW fired indirect combined cycle plant: A novel solution ...uest.ntua.gr/heraklion2019/proceedings/Presentation/3. S. GHOSH.pdf · The study confirms that, such kind of small scale

Parametric Assumptions

19IIEST/SG

Component Parameter/s Value Ref

CCOperating pressure (bar)Pressure drop (bar)

1.0130.05

Mondal & Ghosh 2017 [21]Datta et al., 2009 [22]

HXPressure drop at air sidePressure drop at gas side

3 % of inlet pressure1.5% of inlet pressure

Datta et al., 2009 [22]

C1 Isentropic efficiency (%) 87 Mondal & Ghosh 2017 [21]C2 Isentropic efficiency (%) 90

GTIsentropic efficiency (%)Mechanical Efficiency (%)

8695

HPSTIsentropic efficiency (%)Inlet pressure (bar)Inlet temperature (oC)

8518320

Mondal & Ghosh 2017 [21]

LPSTIsentropic efficiency (%)Inlet pressure (bar)Inlet temperature (oC)

855 (18% of HP)300

HRSGPinch point temperature difference of the Evaporator (oC)

10Mondal & Ghosh 2017 [21]

Cond. ST exhaust pressure (bar) 0.1 Mondal & Ghosh 2017 [21]P Isentropic efficiency (%) 85%

Other assumptionsEnvironmental damage cost due to CO2 emission 0.0145 $/kg Jana & De, 2015 [23]Environmental damage cost due to land filling 12.8 Euro/t of waste Rabl et al., 2008 [9]Plant operating hours 12h-a day basisLoss in transmission line 5%

Page 20: MSW fired indirect combined cycle plant: A novel solution ...uest.ntua.gr/heraklion2019/proceedings/Presentation/3. S. GHOSH.pdf · The study confirms that, such kind of small scale

Base Case Performance

20IIEST/SG

Parameter Unit ValueNet GT output kWe 2327.31

ST1+ST2 output kWe 913.28

Net GT-ST work ratio ---- 3.44

Net electrical efficiency % 44.236

Annualized electricity delivered MWh 12498.73

Electrical specific CO2 emission kg/kWh 0.96

Sustainability index ---- 1.62

Environmental damage cost due to CO2 emission from the plant

$/Y 168845.6

Environmental damage cost due to land filling $/Y 247148.8

Environmental savings compared to land filling $/Y 78303.2

Page 21: MSW fired indirect combined cycle plant: A novel solution ...uest.ntua.gr/heraklion2019/proceedings/Presentation/3. S. GHOSH.pdf · The study confirms that, such kind of small scale

Parametric performance

21IIEST/SG

4 6 8 10 12 14 1636

38

40

42

44

46

Net P

lants

' Ele

ctrica

l Effic

iency

(%

)

Topping Compressor Outlet Pressure (bar)

TIT=900 oC

TIT=1000 oC

TIT=1100 oC

4 6 8 10 12 14 161.0

1.5

2.0

2.5

3.0

3.5

4.0

Net G

T-S

T W

ork

Ratio

Topping Compressor Outlet Pressure (bar)

TIT=900 oC

TIT=1000 oC

TIT=1100 oC

Energetic performance at varying pressure ration of GT

Page 22: MSW fired indirect combined cycle plant: A novel solution ...uest.ntua.gr/heraklion2019/proceedings/Presentation/3. S. GHOSH.pdf · The study confirms that, such kind of small scale

Parametric performance

22IIEST/SG

Exergy destruction and useful exergy

C1+C2 Loss Useful Others

CC ST1+ST2 GT HX

2.59%

42.18%

5.43%

2.36%

9.13%

2.56%1.77%

33.98%

Page 23: MSW fired indirect combined cycle plant: A novel solution ...uest.ntua.gr/heraklion2019/proceedings/Presentation/3. S. GHOSH.pdf · The study confirms that, such kind of small scale

Parametric performance

23IIEST/SG

4 6 8 10 12 14 1690.0

90.5

91.0

91.5

92.0

92.5

93.0

93.5

94.0

94.5

Exe

rgy

Effic

ienc

y of

the

HX

(%

)

Topping Compressor Outlet Pressure (bar)

TIT=900 oC

TIT=1000 oC

TIT=1100 oC

4 6 8 10 12 14 1658

59

60

61

62

63

64

65

Exe

rgy

Effi

cien

cy o

f the

CC

(%

)

Topping Compressor Outlet Pressure (bar)

TIT=900 oC

TIT=1000 oC

TIT=1100 oC

Energetic performance of CC and HX varying pressure ration og GT

Page 24: MSW fired indirect combined cycle plant: A novel solution ...uest.ntua.gr/heraklion2019/proceedings/Presentation/3. S. GHOSH.pdf · The study confirms that, such kind of small scale

Parametric performance

24IIEST/SG

Environmental performance: Specific CO2 emission as well as the sustainability

index (SI).

4 6 8 10 12 14 16

0.84

0.88

0.92

0.96

1.00

1.04

1.08

Spe

cific

CO

2 E

mis

sion (kg

/kW

eh)

Toppong Compresssor Outlet Pressure (bar)

TIT=900 oC

TIT=1000 oC

TIT=1100 oC

4 6 8 10 12 14 16

1.47

1.50

1.53

1.56

1.59

1.62

1.65

1.68

Sust

ain

abili

ty Inde

x

Topping Compressor Outlet Pressure (bar)

TIT=900 oC

TIT=1000 oC

TIT=1100 oC

Page 25: MSW fired indirect combined cycle plant: A novel solution ...uest.ntua.gr/heraklion2019/proceedings/Presentation/3. S. GHOSH.pdf · The study confirms that, such kind of small scale

Conclusion

25IIEST/SG

The study confirms that, such kind of small scale off-grid plant can be beneficial for both sustainable MSW management as well as generation of electricity from MSW to meet the utility power need of the city.

It is observed that, the plant can produce 3 MWe net electrical output at an overall efficiency value of about 44% giving annual production of about 12500 MWh. The specific CO2

emission is 0.96 kg/kWh and SI value is 1.62 at base case.

Furthermore it is observed that, annual environmental damage saving is about 78303$ at base case.