much faster, easier, and more reliableaz621941.vo.msecnd.net/documents/6f321d03-7d5c-48f... · asms...

8
Much Faster, Easier, and More Reliable than Liquid-Liquid Extraction www.phenomenex.com/Novum novum simplified liquid extraction PATENT PENDING

Upload: others

Post on 25-Sep-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Much Faster, Easier, and More Reliableaz621941.vo.msecnd.net/documents/6f321d03-7d5c-48f... · ASMS 2011. Much Faster, Easier, and More Reliable than Liquid-Liquid Extraction Phenomenex

Much Faster, Easier, and More Reliable than Liquid-Liquid Extraction

www.phenomenex.com/Novum

novumsimplified liquid extraction

PATENT PENDING

Page 2: Much Faster, Easier, and More Reliableaz621941.vo.msecnd.net/documents/6f321d03-7d5c-48f... · ASMS 2011. Much Faster, Easier, and More Reliable than Liquid-Liquid Extraction Phenomenex

Phenomenex l WEB: www.phenomenex.com

Simplify Your Liquid-Liquid Extraction Now you can alleviate the challenges associated with traditional liquid-liquid extraction with Novum™ Simplified Liquid Extraction (SLE) (patent pending).

© 2014 Phenomenex, Inc. All rights reserved.

1. Load Your Sample in aqueous solvent

2. Collect Your Target Analytes in water immiscible solvent

Interferences (i.e. phospholipids, proteins, salts, etc.)

Target Analytes

No emulsions

No need to

manually separate liquid

phases

A Simple, Automatable Procedure

Page 3: Much Faster, Easier, and More Reliableaz621941.vo.msecnd.net/documents/6f321d03-7d5c-48f... · ASMS 2011. Much Faster, Easier, and More Reliable than Liquid-Liquid Extraction Phenomenex

Phenomenex l WEB: www.phenomenex.com

0 %

20 %

40 %

60 %

80 %

100 %

120 %

140 %

Cortic

oste

rone

Cortis

one

Cortis

one A

ceta

te

Prednis

one

Testo

stero

ne

Triam

cinolo

ne A

ceto

nide

Rec

over

y (%

)

Lot 1 Lot 2 Lot 3

11α-

OH-pro

geste

rone

A Reliable, Readily Available Product

The unique, synthetic sorbent makes Novum™ SLE a consistent, reliable product in terms of performance and availability.

A consistent, reliable product

proudly manufactured at Phenomenex Headquarters in

Torrance, CA USA

Achieve Consistent Recoveries from Lot-to-Lot

Extraction method1. Load diluted plasma (diluted 1:1 with water) onto Novum SLE MAX 96-well plate, apply vacuum for 2-15 seconds

2. Allow sample to soak into Novum SLE sorbent for 5 minutes

3. Elute with ethyl acetate

Page 4: Much Faster, Easier, and More Reliableaz621941.vo.msecnd.net/documents/6f321d03-7d5c-48f... · ASMS 2011. Much Faster, Easier, and More Reliable than Liquid-Liquid Extraction Phenomenex

Phenomenex l WEB: www.phenomenex.com

Eliminate Interferences from Your AnalysisPhospholipids are present in all bioanalytical samples and can cause a variety of issues in LC/MS/MS analysis including ion suppression, reduced column lifetime, and reduced mass spec sensitivity. Removing phospholipids using Novum™ SLE will dramatically improve your LC/MS/MS data and can increase column lifetime, providing significant cost savings.

Phospholipid Concentration after Cleanup with Novum SLE

Extraction Solvent Lyso 1 Lyso 2 PC 1 PC 2 PC 4Ethyl Acetate (EtOAc) 0 % 0 % 0 % 0 % 0 %

Complete removal of 5 commonly monitored

phospholipids

Lyso 1: 1-Palmitoyl-2-OH-sn-glycero-phosphocholine (m/z 496-184)Lyso 2: 1-Oleoyl-2-OH-sn-glycero-phosphocholine (m/z 522-184)PC 1: 1-Palmitoyl-2-Oleoyl-sn-glycero-phosphocholine (m/z 761-184)PC 2: 1-Stearoyl-2-Lindoleoyl-sn-glycero-phosphocholine (m/z 787-184)PC 4: 1-Oleoyl-2-Lindoleoyl-sn-glycero-phosphocholine (m/z 784-184)

Phospholipids in Diluted Plasma vs. Novum SLE Extracted Plasma

Phospholipid profile monitored using m/z 184-184

00 2 4 6 8 10

100000

22729

90000

80000

70000

60000

50000

40000

30000

20000

10000

App

ID 2

2729

10x Zoom

1/100th Dilution of Precipitated PlasmaNovum EtOAc Extraction

00 2 4 6 8 10

10000

22730

9000

8000

7000

6000

5000

4000

3000

2000

1000

1/100th Dilution of Precipitated PlasmaNovum EtOAc Extraction

00 2 4 6 8 10

10000

22730

9000

8000

7000

6000

5000

4000

3000

2000

1000

App

ID 2

2730

Novum SLE greatly reduces the presence of

phospholipids which will result in improved LC/MS/MS analysis.

Page 5: Much Faster, Easier, and More Reliableaz621941.vo.msecnd.net/documents/6f321d03-7d5c-48f... · ASMS 2011. Much Faster, Easier, and More Reliable than Liquid-Liquid Extraction Phenomenex

Phenomenex l WEB: www.phenomenex.com Phenomenex l WEB: www.phenomenex.com

0 %

20 %

40 %

60 %

80 %

100 %

120 %

Amphe

tam

ine

Bupre

norp

hine

Codein

e

Fent

anyl

MDM

A

MDEA

Mep

eridine

Met

hadon

e

Mep

robam

ate

Met

ham

pheta

mine

Norfe

ntan

yl

Norm

eper

idinePCP

Propox

yphe

ne

Sufen

tanil

Tem

azep

am

Tram

adol

Nordiaz

epam

Rec

over

y (%

)

Consistent, High Recoveries of Target Analytes

Avoid Inferior Results Due to EmulsionsEmulsions are associated with traditional liquid-liquid extraction and are the root cause of analyte loss and contamination. Novum™ SLE eliminates the formation of emulsions, maximizing your analyte recovery while reducing contamination.

Analyte % RSD

Amphetamine 3 %

Buprenorphine 5 %

Codeine 10 %

Fentanyl 6 %

MDEA 4 %

MDMA 4 %

Meperidine 9 %

Meprobamate 7 %

Methadone 2 %

Methamphetamine 12 %

Nordiazepam 1 %

Norfentanyl 3 %

Normeperidine 4 %

PCP 2 %

Propoxyphene 9 %

Sufentanil 11 %

Temazepam 2 %

Tramadol 9 %

Trust Your ResultsNovum SLE simplifies the liquid-liquid extraction process and provides consistent recoveries from sample to sam-ple. Stop worrying about analyte loss due to incomplete manual separation of liquid phases or the formation of emulsions.

Extraction method1. Load diluted urine (diluted 1:1 with 0.5 M Ammonium hydroxide) onto Novum SLE MAX 96-well plate, apply vacuum for 2-15 seconds

2. Allow sample to soak into Novum SLE sorbent for 5 minutes

3. Elute with ethyl acetate

> 80 % recoveries for most analytes

Page 6: Much Faster, Easier, and More Reliableaz621941.vo.msecnd.net/documents/6f321d03-7d5c-48f... · ASMS 2011. Much Faster, Easier, and More Reliable than Liquid-Liquid Extraction Phenomenex

Phenomenex l WEB: www.phenomenex.com

A Simplified Liquid Extraction Novum™ SLE will instantly increase your throughput by eliminating time consuming steps and reducing the risk of analyte loss. If further time savings are necessary, Novum SLE can be easily automated for rapid, hands free sample cleanup.

1. Russell Grant, Matthew Crawford, Brian Rappold, and Stacy Dee. Errors in Bioanalysis Due to Phospholipids – Definitive Measurement, Mechanism, and Management. ASMS 2011.

Visit www.phenomenex.com/Novum for buffer and elution solvent recommendations, technical notes, demonstration videos, and more!

Novum Simplified Liquid Extraction (SLE)

Estimated Time per Sample = <15 minutes

2. Wait 5 minutes

1. Dilute sample 1:1 with buffer or water and load onto Novum SLE sorbent using 2–15 seconds of vacuum

3. Apply elution solvent and allow to elute via gravity. Complete elution with 10 seconds of vacuum.

• Rapid, automatable method for high throughput cleanup

• Stop worrying about analyte loss due to emulsions

Fast and Easy

Traditional Liquid-Liquid Extraction1

Estimated Time per Sample = 25 minutes

4. Pour off or freeze supernatant

1. Dilute sample 1:1 with buffer or water and add extraction solvent

2. Mix for 10 minutes

24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7

6

5

4

3

2 1

3. Centrifuge for 10 minutes

Slow and Laborious

Page 7: Much Faster, Easier, and More Reliableaz621941.vo.msecnd.net/documents/6f321d03-7d5c-48f... · ASMS 2011. Much Faster, Easier, and More Reliable than Liquid-Liquid Extraction Phenomenex

Phenomenex l WEB: www.phenomenex.com Phenomenex l WEB: www.phenomenex.com

Simplify Your Liquid-Liquid Extraction NowOrdering Information

Get Answers to Your QuestionsYour Sample Preparation Specialist is available to assist with method development and optimization. Ask us how Novum SLE can improve your analysis. www.phenomenex.com/mysupport

Information at Your FingertipsAccess applications, videos, webinars, and more! www.phenomenex.com/Novum

Terms and Conditions Subject to Phenomenex Standard Terms and Conditions, which may be viewed at www.phenomenex.com/TermsAndConditions. Trademarks Novum is a trademark of Phenomenex. Disclaimer Novum is patent pending.

© 2014 Phenomenex, Inc. All rights reserved.

If Novum SLE products do not perform as well or better than your current SLE product, return the product with comparative data within 45 days for a FULL REFUND.

AccessoriesCollection Plates (deep well, polypropylene)Part No. Description Unit PriceAH0-7192 96-Well Collection Plate, 350 µL/well 50/pkAH0-7193 96-Well Collection Plate, 1 mL/well 50/pkAH0-7194 96-Well Collection Plate, 2 mL/well 50/pkAH0-8635 96-Well Collection Plate, 2 mL Square/Round-Conical 50/pkAH0-8636 96-Well Collection Plate, 2 mL Round/Round, 8 mm 50/pkAH0-7279 96-Well Collection Plate, 1 mL/well Round, 7 mm 50/pkSealing MatsAH0-8597 Sealing Mats, Pierceable, 96-Square Well, Silicone 50/pkAH0-8598 Sealing Mats, Pre-Slit, 96-Square Well, Silicone 50/pkAH0-8631 Sealing Mats, Pierceable, 96-Round Well 7 mm, Silicone 50/pkAH0-8632 Sealing Mats, Pre-Slit, 96-Round Well 7 mm, Silicone 50/pkAH0-8633 Sealing Mats, Pierceable, 96-Round Well 8 mm, Silicone 50/pkAH0-8634 Sealing Mats, Pre-Slit, 96-Round Well 8 mm, Silicone 50/pkAH0-7362 Sealing Tape Pad 10/pk

Vacuum ManifoldAH0-8950 96-Well Plate Manifold, Universal with Vacuum Gauge ea

Novum™ Simplified Liquid Extraction (SLE)Part No. Description Unit Price8E-S138-FGA Novum SLE MINI 96-Well Plate 1/Box8E-S138-5GA Novum SLE MAX 96-Well Plate 1/Box

1. Russell Grant, Matthew Crawford, Brian Rappold, and Stacy Dee. Errors in Bioanalysis Due to Phospholipids – Definitive Measurement, Mechanism, and Management. ASMS 2011.

Page 8: Much Faster, Easier, and More Reliableaz621941.vo.msecnd.net/documents/6f321d03-7d5c-48f... · ASMS 2011. Much Faster, Easier, and More Reliable than Liquid-Liquid Extraction Phenomenex

Much Faster, Easier, and More Reliable than Liquid-Liquid Extraction

www.phenomenex.comPhenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at [email protected]

novumsimplified liquid extraction

Australiat: +61 (0)2-9428-6444 f: +61 (0)2-9428-6445

[email protected]

Austriat: +43 (0)1-319-1301f: +43 (0)1-319-1300

[email protected]

Belgiumt: +32 (0)2 503 4015 (French)t: +32 (0)2 511 8666 (Dutch)f: +31 (0)30-2383749

[email protected]

Canadat: +1 (800) 543-3681f: +1 (310) 328-7768

[email protected]

Chinat: +86 (0)20 2282-6668f: +86 (0)20 2809-8130

[email protected]

Denmarkt: +45 4824 8048f: +45 4810 6265

[email protected]

Finlandt: +358 (0)9 4789 0063f: +45 4810 6265

[email protected]

Francet: +33 (0)1 30 09 21 10 f: +33 (0)1 30 09 21 11

[email protected]

Germanyt: +49 (0)6021-58830-0f: +49 (0)6021-58830-11

[email protected]

Indiat: +91 (0)40-3012 2400f: +91 (0)40-3012 2411

[email protected]

Irelandt: +353 (0)1 247 5405f: +44 1625-501796

[email protected]

Italyt: +39 051 6327511f: +39 051 6327555

[email protected]

Luxembourgt: +31 (0)30-2418700 f: +31 (0)30-2383749

[email protected]

Mexicot: 001-800-844-5226f: 001-310-328-7768

[email protected]

The Netherlandst: +31 (0)30-2418700 f: +31 (0)30-2383749

[email protected]

New Zealandt: +64 (0)9-4780951f: +64 (0)9-4780952

[email protected]

Norwayt: +47 810 02 005f: +45 4810 6265

[email protected]

Puerto Ricot: +1 (800) 541-HPLCf: +1 (310) 328-7768

[email protected]

Spaint: +34 91-413-8613f: +34 91-413-2290

esp [email protected]

Swedent: +46 (0)8 611 6950f: +45 4810 6265

[email protected]

United Kingdomt: +44 (0)1625-501367f: +44 (0)1625-501796

[email protected]

USAt: +1 (310) 212-0555f: +1 (310) 328-7768

[email protected]

All other countries Corporate Office USA

t: +1 (310) 212-0555f: +1 (310) 328-7768

[email protected]

BR

2438

0714

_W