musett: the segmented si array for the focal plane of the vamos spectrometer
DESCRIPTION
MUSETT: the segmented Si array for the focal plane of the VAMOS spectrometer. Ch. THEISEN – CEA Saclay [email protected]. What is MUSETT. MU r de S ilicium pour l’ E tude des T ransfermium par T agging Collaboration Saclay - Ganil - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: MUSETT: the segmented Si array for the focal plane of the VAMOS spectrometer](https://reader036.vdocuments.net/reader036/viewer/2022062517/56813e5e550346895da86189/html5/thumbnails/1.jpg)
- Christophe THEISEN - INTAG Workshop GSICEA DSM Dapnia SPhNMay 25th, 2007 1
MUSETT: the segmented Si array for the focal plane of theVAMOS spectrometer
Ch. THEISEN – CEA Saclay
![Page 2: MUSETT: the segmented Si array for the focal plane of the VAMOS spectrometer](https://reader036.vdocuments.net/reader036/viewer/2022062517/56813e5e550346895da86189/html5/thumbnails/2.jpg)
- Christophe THEISEN - INTAG Workshop GSICEA DSM Dapnia SPhNMay 25th, 2007 2
What is MUSETT
•MUr de Silicium pour l’Etude des Transfermium par Tagging•Collaboration Saclay - Ganil•Spectroscopy of heavy element with VAMOS and EXOGAM using the RDT
technique
Motivations :•VAMOS : well adapted to asymmetric reactions
– Large angular acceptance– Large transmission– Beam rejection with the Wien Filter
•EXOGAM : high efficiency (single and coincidences).
Constrains:– Very slow and very heavy ions– Optics of Vamos– Alpha particle spectroscopy– Segmentation for the RDT technique– Time stamping– Option : energy loss and tracking of heavy ions
![Page 3: MUSETT: the segmented Si array for the focal plane of the VAMOS spectrometer](https://reader036.vdocuments.net/reader036/viewer/2022062517/56813e5e550346895da86189/html5/thumbnails/3.jpg)
- Christophe THEISEN - INTAG Workshop GSICEA DSM Dapnia SPhNMay 25th, 2007 3
MUSETT at VAMOS + EXOGAM
![Page 4: MUSETT: the segmented Si array for the focal plane of the VAMOS spectrometer](https://reader036.vdocuments.net/reader036/viewer/2022062517/56813e5e550346895da86189/html5/thumbnails/4.jpg)
- Christophe THEISEN - INTAG Workshop GSICEA DSM Dapnia SPhNMay 25th, 2007 4
VAMOS optics
Wien Filter tuned on residues; dipole on
Wien Filter tuned on beam; dipole off
Beam dispersion background
Beam focused
Optics optimized on residues in both cases
![Page 5: MUSETT: the segmented Si array for the focal plane of the VAMOS spectrometer](https://reader036.vdocuments.net/reader036/viewer/2022062517/56813e5e550346895da86189/html5/thumbnails/5.jpg)
- Christophe THEISEN - INTAG Workshop GSICEA DSM Dapnia SPhNMay 25th, 2007 5
VAMOS optics
Beam
1+ 5+ 10+
Beam
WF tuned on recoils WF tuned on beam
![Page 6: MUSETT: the segmented Si array for the focal plane of the VAMOS spectrometer](https://reader036.vdocuments.net/reader036/viewer/2022062517/56813e5e550346895da86189/html5/thumbnails/6.jpg)
- Christophe THEISEN - INTAG Workshop GSICEA DSM Dapnia SPhNMay 25th, 2007 6
Si detectors
(Not a MUST II detector, this is a MUSETT one…)
![Page 7: MUSETT: the segmented Si array for the focal plane of the VAMOS spectrometer](https://reader036.vdocuments.net/reader036/viewer/2022062517/56813e5e550346895da86189/html5/thumbnails/7.jpg)
- Christophe THEISEN - INTAG Workshop GSICEA DSM Dapnia SPhNMay 25th, 2007 7
Si detectors
•Characteristics
– 300 μm thick
– 10 x 10 cm2
– 128 + 128 strips
– 3 % Al grid
– Front side : No Aluminum layer. < 0.25 μm B implantation
– Depletion ~ 30 V. Nominal voltage ~ 60 V.
– Provided by Micron Semiconductor
– 2 evaluation detector + 1 prototype received
![Page 8: MUSETT: the segmented Si array for the focal plane of the VAMOS spectrometer](https://reader036.vdocuments.net/reader036/viewer/2022062517/56813e5e550346895da86189/html5/thumbnails/8.jpg)
- Christophe THEISEN - INTAG Workshop GSICEA DSM Dapnia SPhNMay 25th, 2007 8
Si detectors
![Page 9: MUSETT: the segmented Si array for the focal plane of the VAMOS spectrometer](https://reader036.vdocuments.net/reader036/viewer/2022062517/56813e5e550346895da86189/html5/thumbnails/9.jpg)
- Christophe THEISEN - INTAG Workshop GSICEA DSM Dapnia SPhNMay 25th, 2007 9
Si detectors mechanics
![Page 10: MUSETT: the segmented Si array for the focal plane of the VAMOS spectrometer](https://reader036.vdocuments.net/reader036/viewer/2022062517/56813e5e550346895da86189/html5/thumbnails/10.jpg)
- Christophe THEISEN - INTAG Workshop GSICEA DSM Dapnia SPhNMay 25th, 2007 10
Electronics and DAQ for Si detectors
•See next presentation…
ATHED
CVM
MUVI
![Page 11: MUSETT: the segmented Si array for the focal plane of the VAMOS spectrometer](https://reader036.vdocuments.net/reader036/viewer/2022062517/56813e5e550346895da86189/html5/thumbnails/11.jpg)
- Christophe THEISEN - INTAG Workshop GSICEA DSM Dapnia SPhNMay 25th, 2007 11
Gas detectors
Bi 150MeV55 MeV
D DSSD
Elect
16 MeV
Elect
57 MeV
α
IC
Elect
5-10 Torr Iso
Energy loss
Escaped radioactivity
![Page 12: MUSETT: the segmented Si array for the focal plane of the VAMOS spectrometer](https://reader036.vdocuments.net/reader036/viewer/2022062517/56813e5e550346895da86189/html5/thumbnails/12.jpg)
- Christophe THEISEN - INTAG Workshop GSICEA DSM Dapnia SPhNMay 25th, 2007 12
Gas detector
Constrains
•Large dynamics : heavy ions + escaped radioactivity
– Hybrid detector Ionisation Chamber + Drift Chamber
•Small energy loss of heavy ions
– Low pressure
•Small effect on/off Si Wall
•Coexistence of IC/DC fields
•Integration in HARPEE mechanics
![Page 13: MUSETT: the segmented Si array for the focal plane of the VAMOS spectrometer](https://reader036.vdocuments.net/reader036/viewer/2022062517/56813e5e550346895da86189/html5/thumbnails/13.jpg)
- Christophe THEISEN - INTAG Workshop GSICEA DSM Dapnia SPhNMay 25th, 2007 13
Mechanics integration
•Integration in the HARPEE mechanics : easy installation / maintenance
– Si Wall module
– Gas detector module
![Page 14: MUSETT: the segmented Si array for the focal plane of the VAMOS spectrometer](https://reader036.vdocuments.net/reader036/viewer/2022062517/56813e5e550346895da86189/html5/thumbnails/14.jpg)
- Christophe THEISEN - INTAG Workshop GSICEA DSM Dapnia SPhNMay 25th, 2007 14
Status
•3 Si detectors received
•ATHED ASICs : ready
•COFEE Front-end being tested
•CVM VME readout and DAQ ready. Need to be tested with COFEE.
•MUVI VXI readout : prototypes OK. Production soon
•Mechanics for Si : drawing ready, prototype soon
•Gas detector : R & D phase. Prototype 2007
![Page 15: MUSETT: the segmented Si array for the focal plane of the VAMOS spectrometer](https://reader036.vdocuments.net/reader036/viewer/2022062517/56813e5e550346895da86189/html5/thumbnails/15.jpg)
- Christophe THEISEN - INTAG Workshop GSICEA DSM Dapnia SPhNMay 25th, 2007 15
Perspectives
S3 focal plane
SPIRAL2