SPLIT-TYPE AIR CONDITIONERS

Natural Comfort For

Everybody

POWER CEILING CASSETTE

WALL MOUNTED

CEILING SUSPENDED

CEILING CONCEALEDR22

P R O D U C T L I N E - U P

2.5hp 3hp

PKH-FAKWall mounted

PCH-GAKCeiling suspended

OUTDOOR UNIT

PLH-AAKPower ceiling cassette

PEH-EAKCeiling concealed

PCH-3GAK

PLH-3AAK

PEH-3EAKPEH-2.5EAK

PUH-2.5AKA PUH-3VKA*/PUH-3YKA

PKH-3FAK

1

*PUH-3VKA is only for PEH series.

4hp 5hp 6hp

P.7

P.8

P.9

P.10

Remote controller Contents

PCH-4GAK PCH-5GAK PCH-6GAK

PLH-4AAK PLH-5AAK PLH-6AAK

PEH-5EAK PEH-6EAKPEH-4EAK

PUH-4YKSA PUH-5YKSA PUH-6YKSA

PKH-4FAK

2

Optional

Mitsubishi Electric Offers Three Important Advantages

In today’s competitive environment, simply meeting industry standards, however

stringent, is not enough. Our aim is to exceed them. That’s why when it comes to

comfort, efficiency and durability: Mitsubishi Electric offers you a distinctive advantage.

We call it MEQ — Mitsubishi Electric Quality. And it's a new benchmark that results

in leading edge products, such as air conditioners that consume minimal power and

protect your investment with a long operational lifespan. You can also enjoy superb

reliability, as they’re built to endure the punishment of extreme weather conditions

year in and year out.

True Comfort is Yours toEnjoy with Our Line-up

We create products designed toensure that you and your surroundingwill always be in a perfect harmony.Whichever model from our Mr. SLIMline-up you may choose for commer-cial use in restaurants, stores, oroffices will be your guarantee ofexceptional comfort in every and alloperating condition.

Comfort

Optimum Cost Performanceand Energy Savings

MEQ results in air conditioners thatare rated among the best in theindustry in terms of quality and energyefficiency. We strive for a perfect bal-ance of performance, reliability, lowpower consumption and long opera-tional life span. This is complement-ed by continuous introduction of newtechnologies and components thatfurther reduce energy requirementsand improve eco-friendliness.

Efficiency

Rugged Construction, RigorousTesting, Long-lasting OperationMEQ is behind a mindset that goes toextremes to ensure higher qualityproducts that protect the initialinvestment over years of reliable ser-vice. We subject our indoor and outdoor units to rigorous durabilitytesting, including harsher tempera-ture extremes than likely found anywhere in the world.

Durability

3

High performance, low power consumption, and excellent reliability.

The MEQ Difference

Multi-language Display

Weekly TimerThe function of the weekly timer equipped can change the set

temperature in addition to the ON/OFF control. Up to 8 pat-

terns can be set for each calendar day.

Whatever your requirements may be, Mitsubishi Electric offers advanced

split-type heat pumps perfect for any interior, any need. Significantly

decreased noise levels enhance comfort while a long list of convenient

features allow for easy installation and far less maintenance. A variety of

system control configurations plus twin multi operation — where multiple

indoor units can be connected to a single outdoor unit — make

our units the first choice for the diverse applications of today.

The First Choicefor Any and All Applications

New Remote Controller

Renovating air conditioning communication by advanced MA Remote Controller newly developed

4

Multi-Ianguage

8 languages can be displayed.Display can be switched over for 8 kinds of language.

[English] [Spanish] [Italian] [German]

[French] [Russian] [Chinese] [Japanese]

Dot Liquid Crystal DisplayAcknowledging the operation and control status at a glance.

The large size display upgrades visual acknowledgement

capability. The operation and control status can be understood

promptly.

Operation Control Function

Display example [Operation mode]Dot liquid crystal display section

Limiting the set temperature range

Air conditioning operation always within a limited temperature range

Auto Off timerAutomatic turning off of air conditioning operation

Operation lockingPreventing the randommodification of setting

Control function System configuration Necessary parts & equipment

■ Timer adapter PAC-SE55RA-E(connect to CN32 on indoor circuit board)

■ Relay box (on-site)

■ MAC-397IF-E(one for each outdoor unit)

■ Additional remote controller (option)

■ Remote controller cord (on-site)

■ Timer adapter PAC-SE55RA-E(connect to CN32 on indoor circuit board)

■ Timer adapter PAC-SE55RA-E(connect to CN32 on indoor circuit board)

■ Multiple remote controller adpter PAC-725AD(connect to CN51 on indoor circuit board)

■ Function setting by remote controller

1.Group controlwith 1 remotecontroller

2.CombinedRemote/localcontrol

3.Operation with2 remotecontrollers

4.Individualcontrol fromdistant room

5. Timer operation

6. Operation byexternal signal

7.Power failureautomaticrecovery

8. Connection ofremote display

■ Multiple remote controller adpter PAC-725AD (connect to CN51 on indoor circuit board)

■ Relay OMRON made LY-1 (DC12V)

■ Sequential start adaptable■ Same mode operation■ Maximum no. of units connectable per

group: 16-refrigerant (Outdoor 16 sets)

■ Simultaneous ON/OFF remote■ Operation can be switched between

the distant controller panel and handheld controller

■ 2 remote controllers can be connected to one group

■ Control with the latest command

(MAX. 500m)■ Extension of remote controller cord

■ Weekly timer operation possible as standard (7 days-8 patterns)

■ Optional adapter allows operation with timer sold on the market

■ Static signal receivable

■ Pulse signal receivable

■ Returns to the state before power failure as standard

■ Connectable to display panel in the field adapter

Features

1

Remote Controller Indoor Unit

Outdoor Unit

InterfaceInterface

DistantControllerPanel

Remote Controller

Indoor Unit

RelayBox Adapter

Remote Controller

Indoor Unit

Remote Controller Indoor Unit

Remote Controller

PowerSupply

Indoor Unit

Remote Controller

Adapter

DistantDisplay

Indoor Unit

RelayBox

Mr. SLIM New A/K Control System Configuration

5

PAC-SE55RA-ETimer Adapter

MAC-397IF-EMA & Control Terminal Interface

PAC-725ADMultiple Remote Controller Adapter

(10 units of PAC-SA88HA-E)

Stylish wireless remote controller with all the latest programming features

Wireless remote controller for PLH-AAK

Mr. SLIM Convenient Remote Controller

● FAN SPEED SELECT buttonUsed to change fan speed.

● VANE CONTROL buttonUsed to change airflow direction.

● MODE SELECTION buttonUsed to select operating modes — Cool, Dry, and Heat, and Auto.

● TIMER CONTROL buttonsSTOP (OFF timer): When this function isactivated, the air conditioner will auto-matically stop at the preset time.

START (ON timer): When this function isactivated, the air conditioner will auto-matically start at the preset time.

● Fan speed indicatorDisplays the fan speed setting (HIGH or LOW).

● HOUR and MINUTE buttons

Used to set the time and timer settings.

● TIMER button/RESET button

Advanced MA remote controller

Wired remote controller*

● DOT LIQUID CRYSTAL display

● MULTI-LANGUAGE display

● OPERATION CONTROL function

● WEEKLY TIMER

6

Twin Multi Operation

Note● The capacity of both indoor units must be identical.

● Different types of indoor units with identical capacities can be connected.

● The height difference between both indoor units must be 1meter orless.

● When two units are connected, the main unit can be used to controlthe operation of all units.

2.5HP 3HP

PEH-2.5EAK

PKH-3FAKPCH-3GAKPLH-3AAKPEH-3EAK

Twin-multiOutdoor unit

50:50PUH-5YKSA 2.5 + 2.5PUH-6YKSA 3 + 3Multi-distribution pipe SDD-50S-E

Applicable indoor units

Outdoor Unit and Twin-Multi Combinations

INDOOR UNIT INDOOR UNIT

OUTDOOR UNIT

Multi-Distribution Pipe

Two indoor units can be connected to a single outdoor unit

and all units can be operated simultaneously from a single

remote controller using the optional multi-distribution pipe

(only indoor units of the same capacity and type can be

connected).

*Please refer to page 4.

Design uniformity improves installation flexibilityFrom the smallest 3HP unit to the largest 6HP model, the new high-power ceiling cassettes offer a uniformly square 950 x 950mm widthand depth design. Thanks to the uniformity of the panel size, planningfor unit positioning in any room is enhanced and the installation of dif-ferent capacity models within the same floor space is made possible.

Unit height of only 258mm [PLH-3]The new high-power ceiling cassette models boast slim body height for smooth and aesthetic installation even in limited ceiling plenum applications.

PLH-3AAK

258mm

PLH-4/5/6AAK

298mm

(40mm less than conventional models)

Automatic vane shutterWhen the air conditioner is not operat-ing, the vane shutter* closes automati-cally to conceal the air outlet and create an aesthetically appealing flatsurface.* This feature will not activate when the vane is set atfixed position.

Wide-flow air outletThe new high-power ceiling cassettes offer a wide-flow air outlet that enables effective air con-ditioning of atrium-type ceilings upto 4.2 meters in height.The demands of high-ceiling applications suchas halls, showrooms orshopping malls can nowbe fully answered thanks to this powerful yet highlyefficient airflow.

Vane shutter closes automatically

During operation When turned off

Ideal for high-ceiling applications

as high as

4.2m(PLH-4/5/6)

■ 4-way high ceiling 2

■ 3-way standard

■ 4-way standard

3.2m

4.2m

3.6m

Power Cassette

* Optional air outlet shutter plate (PAC-SG06SP-E) is necessary for two- or three-way airflow settings.

Specifications according to ceiling height and number of ventsPLH-3 PLH-4/5/6

dradnatS hgiH 1gniliec hgiH 2gniliec dradnatS hgiH 1gniliec hgiH 2gniliec

yaw-4 7.2 0.3 5.3 2.3 6.3 2.4

yaw-3 0.3 3.3 5.3 6.3 0.4 2.4

yaw-2 3.3 5.3 — 0.4 2.4 —

20%lighter!

34dB/28dBPLA-P3/PLH-P3 at hi-notch/lo-notch

Fresh Air Intake

P O W E R C E I L I N G C A S S E T T E

PLH-3AAK PLH-4AAK PLH-5AAK PLH-6AAK

INDEX

Specifications .........................................p.11 Option ......................................................p.13

PLH-AAKS E R I E S

7

Features at-a-glanceInstallation & Maintenance Comfort Others• Chargeless system • Auto-angle airflow • System control• Compact • Drain

design • Versatile airflow • Twin-multi operation water lift-up (850mm) • 72 airflow patterns • Auto vane shutter

• Smudge/draft free • Auto restart• Long-life filter (2500 hrs.) • High ceiling application • Self-diagnostic function

• Quiet • Bacteria- and mold-resistant fiter

operation

• Fresh air intake

• Outdoor unit operating

range up to 46ºC

Handy corner-pocket•

• Computerized dehumidifier• Filter indicator

(For wired remote controller)•

Flockless vanes

8

INDEX

Specifications .........................................p.11 Option ......................................................p.13

PKH-FAKS E R I E S

PKH-3FAK PKH-4FAK

Auto-flap shutterWhen the unit is turned off, the shutter closes automatically over the air outlet to enhance the stylishdesign. The shutter also functions as a flap to adjust airflow angle toensure that comforting air reaches every corner of the room.

Enhanced noise suppressionLow-noise operation has beenachieved through the introductionof a “near-silent” fan and adesign which minimises airflowresistance.

Multi-directional pipingTo reduce installation time, drain piping can be connected from leftand right. Refrigerant piping can also be connected from the rear, left,right and base of the unit.

Easy removable filterConvenient thumbscrews on the filters enable the filters to be quickly removed foreasier cleaning.

Back plate installation guideTo save time and effort, the back plate installation guide provides clearinstructions on installation positions. The enlarged back plate securesthe unit firmly to the wall, while the support piece which lifts the unitmakes the left-side piping work much easier.

Drain lift-up mechanism (optional)For greater installation flexibility, the drain water pipe lift-up mecha-nism has been raised 800mm from the base of the unit.

Features at-a-glanceInstallation & Maintenance Comfort Others• Chargeless system • Auto-angle airflow • System control • Computerized dehumidifier • Twin-multi operation • Easy removable filter

• Quiet operation • Auto-flap shutter • 4-way multi directional piping • Drain water lift-up (800mm)*

• Self-diagnostic function• Outdoor unit operating

range up to 46ºC

*Optional

(dB)

Model Sound pressure level (Lo/Hi)

PKH-3 39/45

PKH-4 41/46

W A L L M O U N T E D

Direct suspension with attachment fixture attached

1. Leave attachment fixture attached to main unit.2. Suspend the attachment fixture from the suspension bolts.3. Simply tighten the nuts to secure the unit.

Ceiling surface Suspension bolts

Air outlet

Attachment fixture

Extra slim, extra stylishSleek and slim with stylishly curved lines, the PCH-GAK Series blendsright into any interior. It also features a single air outlet with an autovane that closes like a shutter when the unit is turned off to enhanceoverall appearance.

Innovative auto vane systemThe auto vane system swings up and downautomatically to distribute air more evenlythroughout the room.

Quiet and comfortable Smoother airflow, an improved air vent design, and a slimmer fan combine to provide exceptionally quiet operation — a mere 43dB onhigh and 37dB on low (PCH-3GAK).

New direct suspension systemFor easier installation, the PCH-GAK Series features a new direct sus-pension system that makes it unnecessary to remove nuts and boltsfrom the main body. A one-touch suspension system is also available.

Piping flexibility simplifies installationAll piping, including those related to drainage, can be connected fromthe right, rear and top of the unit. This provides greater flexibility inselecting piping layout and installation locations.

Flockless vanesWith the adoption of new flockless vanes, dirt and other impurities canbe cleaned off easily with mild household detergent.

Fan phase control plus microprocessor control allowairflow settings to match ceiling height.

Drain water lift-up mechanism can be pre-installed(optional).

Swing

Auto vane

Features at-a-glanceInstallation & Maintenance Comfort Others• Chargeless system • Auto swing • System control• New direct suspension

system• High ceiling application • Twin-multi operation

• Drain water lift-up (500mm)*•

Computerized dehumidifier

Flexible piping•

Quiet operation• Auto restart

• Long-life filter (2500 hrs.)

• Auto vane shutter

• Self-diagnostic function

• Outdoor unit operatingrange up to 46ºC

• Washable filter*

*Optional

C E I L I N G S U S P E N D E D

INDEX

Specifications .........................................p.12 Option ......................................................p.13

PCH-GAKS E R I E S

PCH-3GAK PCH-4GAK

PCH-5GAK PCH-6GAK

9

10

C E I L I N G C O N C E A L E D

Limitless installation possibilitiesOffering all the benefits of split-type models plus other importantadvantages, the PEH-EAK Series is not only easy to install but also veryversatile. For example, the distance between the air-intake and air-out-let vents can be varied to allow airflow to be positioned in the opti-mum location.

Computerized dehumidification The computerized dehumidifier mode — where fan speed is controlledprecisely — increases dehumidification volume while improving dehu-midifying efficiency.

PEH-2.5EAK PEH-3EAK

PEH-4EAK PEH-5EAK PEH-6EAK

INDEX

Specifications .........................................p.12Option ......................................................p.13

Features at-a-glanceInstallation & Maintenance Comfort Others• Chargeless system • Computerized dehumidifier • System control• Smooth instllation • Quiet operation • Twin-multi operation • Self-diagnostic function • Auto restart

• Outdoor unit operatingrange up to 46ºC

Long-rectangular room

L-shaped room

Room withfixed ceilingfixtures

PEH-EAKS E R I E S

PEH-2.5EAK PEH-3EAKPEH-4EAK

PEH-5EAKPEH-6EAK

PLH-AAK POWER CEILING CASSETTE

S P E C I F I C A T I O N S

11

Models PLH-3AAK PLH-4AAK PLH-5AAK PLH-6AAKFunction Heating

W 7,700 16,100CapacityTotal input kW 3.32 4.51 4.46 5.07 4.92COP W/W 2.32 2.75 3.14 2.76 3.27

Model name PLH-3AAK PLH-4AAK PLH-5AAK PLH-6AAK

External finish Galvanized sheets with gray heat insulationPower supply

Airflow ( Lo-Hi) l/s 250 – 333 333 – 467 367 – 500

External static pressure Pa ( mmAq) 0 (direct blow)

Sound pressure level ( Lo-Hi) dB 28 – 34 33 – 41 35 – 43 37 – 45

W mm 840

D mm 840 Dimensions

H mm 258 298

Indoor unit

Weight kg 24 30 30 32

External finish Munsell 0.70Y 8.59/0.97W mm 950 D mm 950 DimensionsH mm 30

Indoor grille

Weight kg 5

Model name PUH-3YKA PUH-4YKSA PUH-5YKSA PUH-6YKSA

External finish

Single phase, 50Hz, 240V

Munsell 5Y 7/1

Power supply 3-phase 50Hz, 415V (4 wires)

Refrigerant (R-22) control Capillary tubeCompressor output kW 2.4 2.7 3.5 4.0

Protection devicesInternal thermostat, HP switch / thermal relay, thermal switch,

anti- phase protectorThermal relay, thermal switch, HP switch, anti-phase protector

Airflow l/s 833 1,584 1,667

Crankcase heater W 38

Sound pressure level dB 52 54 55 56

Sound power level dB 66 69 70 71

W mm 870 970

D mm 295 + 24 345 + 24 Dimensions

H mm 850 1,258

Outdoor unit

Weight kg 75 94 114 117

Heating14,000

Cooling14,000

Cooling12,400

Heating10,400

3.453.01

Cooling9,7003.462.80

Heating8,4003.112.70

Cooling

sledoM FAK3-HKP FAK4-HKPnoitcnuF gnilooC gnitaeH gnilooC gnitaeH

yticapaC W 009,7 001,9 005,9 007,01

tupnilatoT Wk 52.3 40.3 13.3 03.3

POC W/W 34.2 00.3 78.2 42.3

tinuroodnI

emanledoM FAK3-HKP FAK4-HKPhsiniflanretxE 8.0/7.7Y4.3llesnuMylppusrewoP V042,zH05,esahpelgniS

)iH-oL(wolfriA s/l 250 – 333 367 – 467

erusserpcitatslanretxE )qAmm(aP )wolbtcerid(0

)iH-oL(levelerusserpdnuoS Bd 39 – 45 41 – 46

snoisnemiD

004,1 086,1

mmD 532

mmH 043

thgieW gk 42 82

tinuroodtuO

emanledoM AKY3-HUP ASKY4-HUPhsiniflanretxE 1/7Y5llesnuMylppusrewoP )seriw4(V514,zH05,.hp-3

lortnoc)22-R(tnaregirfeR ebutyrallipaC

tuptuorosserpmoC Wk 4.2 7.2

secivednoitcetorP lamreht/hctiwsPH,tatsomrehtlanretnI ,hctiwsPH,hctiwslamreht,yaler-itna rotcetorpesahp PH,hctiwslamreht,yalerlamrehT rotcetorpesahp-itna,hctiws

wolfriA s/l 338 485,1

retaehesacknarC W 83

levelerusserpdnuoS Bd 25 45

levelrewopdnuoS Bd 66 96

snoisnemiD

mmW 078

mmD 42+592

mmH 058 852,1

thgieW gk 57 49

mmW

PKH-FAK WALL MOUNTED

12

S P E C I F I C A T I O N S

PEH-EAK CEILING CONCEALED

PCH-GAK CEILING SUSPENDEDsledoM GAK3-HCP GAK4-HCP GAK5-HCP 6GAK-HCP

noitcnuF gnilooC gnitaeH gnilooC gnitaeH gnilooC gnitaeH gnilooC gnitaeH

yticapaC W 006,7 005,8 000,01 054,01 004,21 009,31 005,41 000,51

tupnilatoT Wk 82.3 70.3 63.3 53.3 54.4 04.4 79.4 28.4

POC W/W 23.2 77.2 89.2 21.3 97.2 61.3 29.2 11.3

tinuroodnI

emanledoM GAK3-HCP GAK4-HCP G5GAK-HCP GAK6-HCPhsiniflanretxE 79.0/95.8Y07.0llesnuM

ylppusrewoP V042,zH05,esahpelgniS

)iH-oL(wolfriA s/l 233 – 300 333 – 417 450 – 567

erusserpcitatslanretxE )qAmm(aP )wolbtcerid(0

)iH-oL(levelerusserpdnuoS Bd 37 – 43 40 – 45 41 – 46 42 – 48

snoisnemiD

W mm 013,1 026,1

D mm 086

H mm 012 072

thgieW gk 7343 34 54

tinuroodtuO

emanledoM AKY3-HUP ASKY4-HUP ASKY5-HUP ASKY6-HUP

hsiniflanretxE 1/7Y5llesnuMylppusrewoP V514,zH05,.hp-3 )seriw4(

lortnoc)22-R(tnaregirfeR ebutyrallipaC

tuptuorosserpmoC Wk 4.2 7.2 5.3 0.4

secivednoitcetorP -itna,hctiwsPH,hctiwslamreht,tatsomrehtlanretnI rotcetorpesahp

wolfriA s/l 338 485,1 766,1

retaehesacknarC W 83

levelerusserpdnuoS Bd 25 45 55 65

snoisnemiD

W mm 078 079

D mm 42+592 42+543

H mm 058 852,1

thgieW gk 57

Internal thermostat, HP switch/thermal relay, thermal switch, HP switch,

anti-phase protector

thermal relay, thermal switch, HP switch, anti-phase protector

49 411 711

power leveldnuoS Bd 6 6 96 07 17

sledoM EAK5.2-HEP EAK3-HEP EAK4-HEP EAK5-HEP EAK6-HEPnoitcnuF gnilooC gnitaeH gnilooC gnitaeH gnilooC gnitaeH gnilooC gnitaeH gnilooC gnitaeH

yticapaC W 007,6 008,6 000,8 003,8 007,9 004,01 004,21 000,31 002,51 004,71

tupnilatoT Wk 09.2 17.2 74.3 33.3 46.3 36.3 68.4 18.4 18.5 66.5

POC W/W 13.2 15.2 13.2 94.2 66.2 78.2 55.2 07.2 26.2 70.3

emanledoM EAK5.2-HEP EAK3-HEP EAK4-HEP EAK5-HEP EAK6-HEPhsiniflanretxE steehsdezinavlaG

ylppusrewoP V042,zH05,esahpelgniS

tinuroodnI

)iH-oL(wolfriA s/l 367 – 450 450 – 567 567 – 700 800 – 1,000

erusserpcitatslanretxE )qAmm(aP hcton-iHta)7.21(721

)iH-oL(levelerusserpdnuoS Bd 52 – 55 54 – 58 51 – 55

snoisnemiD

mmW 587 550,1 552,1 514,1

mmD 096

mmH 824

thgieW gk 54 64 85 27 37

tinuroodtuO

emanledoM AKA5.2-HUP AKY3-HUP/AKV3-HUP ASKY4-HUP ASKY5-HUP ASKY6-HUPhsiniflanretxE 1/7Y5llesnuM

ylppusrewoP V042,zH05,.hpelgniS/V042,zH05,.hpelgniS

)seriw4(V514,zH05,.hp-3)seriw4(V514,zH05,.hp-3

lortnoc)22-R(tnaregirfeR ebutyrallipaC

tuptuorosserpmoC Wk 0.2 4.2/2.2 7.2 5.3 0.4

secivednoitcetorP,tatsomrehtlanretnI

hctiwsPH

PH,tatsomrehtlamretnIlamreht,yalerlamreht/hctiws

-itna,hctiwsPH,hctiwsrotcetorpesahp

lamreht,yalerlamrehT-itna,hctiwsPH,hctiws

rotcetorpesahp

,tatsomrehtlanretnI,hctiwslamreht

rotcetorpesahp-itna,hctiwsPH

wolfriA s/l 338 485,1 766,1

retaehesacknarC W 83

levelerusserpdnuoS Bd 25 45 55 65

levelrewopdnuoS Bd 66 96 07 17

snoisnemiD

mmW 078 079

mmD 42+592 42+543

mmH 058 852,1

thgieW gk 86 57 49 411 711

13

GEN ER AL SP EC I F IC AC ION S FOR ALL MODELS

■ Main Optional PartsledoM noitpircseD sledomelbacilppA

DA527-CAP )stes01(retpadArellortnoCetomeRelpitluM New A/K control

PAC-SE55RA-E Timer Adapter New A/K control

MAC-397IF-E MA & Control Terminal Interface New A/K control

New A/K controlPAC-SE41TS-E rosneSetomeRE-SD64AS-CAP tekcoSniarD 2.5~4-HUP

E-SD74AS-CAP tekcoSniarD 6/5-HUP

D-GS292-CAP ediuGteltuOriA 2.5~6-HUP

E-S05-DDS esUniwTrofepiPnoitubirtsiD 5/6-HUP

E-MD58ES-CAP msinahceMpU-tfiLniarD 3-HCP

E-M

A

AD68ES-CAP msinahceMpU-tfiLniarD 6~4-HCP

E-FK18ES-CAP retliFycneiciffEhgiH 3/4-HCP

E-FK28ES-CAP retliFycneiciffEhgiH 5/6-HCP

PAR-SL99B-E Wireless Remote Controller PCH series

PAR-SL97A-E Wireless Remote Controller PLH series

tnemelEretliFycneiciffEhgiHPAC-SG01KF PLH series

etalPrettuhSteltuOriAPAC-SG06SP-E PLH series

tnemesaCnoitcnuF-itluMPAC-SG03TM-E PLH series

■ Refrigerant PipingBetween indoor & outdoor units Pipe size O.D., mm

ModelsMax. height difference, m Max. piping length, m Max. number of bends Liquid Gas

PLH-3AAK, PKH-3FAK, PCH-3GAK, PEH-2.5EAK, PEH-3EAK

50 50 15 Ø 9.52 Ø 15.88

PKH-4FAK PLH-4/5/6AAK,PCH-4/5/6GAK, PEH-4/5/6EAK

50 50 15 Ø 9.52 Ø 19.05

■ Optional Refrigerant PipesPipe length Part number5m (16ft) PAC-05FFS-E PAC-SC51PI-E7m (23ft) PAC-07FFS-E PAC-SC52PI-E10m (33ft) PAC-10FFS-E PAC-SC53PI-E15m (49ft) PAC-15FFS-E PAC-SC54PI-EConnection method Flared-flared Flared-flaredPipe size OD, mm (ft) Liquid: Ø 9.52 (3/8) Gas: Ø 15.88 (5/8) Liquid: Ø 9.52 (3/8) Gas: Ø 19.05 (3/4)Applicable models PKH-3FAK, PLH-3AAK, PCH-3GAK, PEH-2.5EAK, PEH-3EAK PKH-4FAK, PLH-4/5/6AAK, PCH-4/5/6GAK, PEH-4/5/6EAK

■ Additional Refrigerant Charge [R-22: kg]Piping length (one-way)

Models5m 10m 15m 20m 25m 30m 35m 40m 45m 50m

PUH-2.5AKA 0 0 0 0 0 0 0.2 0.2 0.5 0.5PUH-3VKA/PUH-3YKA 0 0 0 0 0 0 0.2 0.2 0.5 0.5PUH-4YKSA 0 0 0 0 0 0 0.3 0.3 0.6 0.6PUH-5YKSA 0 0 0 0 0 0 0.3 0.3 0.6 0.6PUH-6YKSA 0 0 0 0 0 0 0.3 0.3 0.6 0.6

■ Guaranteed Operating RangeLimits Indoors Outdoors

Lower 21ºC DB, 15.5ºC WB -5ºC DB Cooling

Upper 35ºC DB, 22.5ºC WB 46ºC DBLower 20ºC DB -8.5ºC DB, -9.5ºC WB

HeatingUpper 27ºC DB 21ºC DB, 15.5ºC WB

■ Notes for All Specifications● Rating conditions: Cooling - Indoor 27ºCDB, 19ºCWB; Outdoor 35ºCDB

Heating - Indoor 20ºCDB ; Outdoor 7ºCDB,6ºCWB

● Data based on indicated voltage Indoor unit : 1-ph, 240V, 50HzOutdoor unit : 1-ph, 240V, 50Hz/3-ph, 415V, 50Hz

● Refrigerant piping length (one-way): 5m (16ft)

● Refrigerant charge is suitable for 5m piping length.

■ Cooling Capacity Correction FactorsModels Correction factors (Cooling / Heating)One-way piping length, m 5 10 15 20 25 30 35 40 45 50PEH-2.5EAK 1.00/1.00 0.989/1.00 0.980/1.00 0.970/1.00 0.960/1.00 0.950/1.00 0 .9 40 /0 . 99 8 0 .9 30 /0 . 99 5 0 .9 20 /0 . 99 3 0 .9 10 /0 . 99 0PKH-3FAK, PCH-3GAK,PLH-3AAK, PEH-3EAK 1.00/1.00 0.981/1.00 0.968/1.00 0.952/1.00 0.940/1.00 0.925/1.00 0 .9 13 /0 . 99 8 0 .9 00 /0 . 99 5 0 .8 86 /0 . 99 3 0 .8 74 /0 . 99 0

PKH-4FAK PCH-4GAK,PLH-4AAK, PEH-4EAK 1.00/1.00 0.989/1.00 0.980/1.00 0.970/1.00 0.960/1.00 0.950/1.00 0 .9 40 /0 . 99 8 0 .9 30 /0 . 99 5 0 .9 20 /0 . 99 3 0 .9 10 /0 . 99 0

PCH-5GAK PLH-5AAK,PEH-5EAK 1.00/1.00 0.981/1.00 0.968/1.00 0.952/1.00 0.940/1.00 0.925/1.00 0 .9 13 /0 . 99 8 0 .9 00 /0 . 99 5 0 .8 86 /0 . 99 3 0 .8 74 /0 . 99 0

PCH-6GAK, PLH-6AAKPEH-6EAK 1.00/1.00 0.975/1.00 0.955/1.00 0.935/1.00 0.918/1.00 0.900/1.00 0 .8 84 /0 . 99 8 0 .8 69 /0 . 99 5 0 .8 55 /0 . 99 3 0 .8 40 /0 . 99 0

14

■ When used in rooms with high ceilings, it is recommended that a ceiling fan orcirculator be installed to improve air circulation and temperature variations withinthe room.

■ The remote-control circuits under microprocessor control remain on at all times whether the air conditioner is or is not in operation. For more economicaloperation, it is recommended that the main power switch be turned off when theair conditioner(s) is not used for long periods.

■ Avoid using air conditioning units in areas where they are exposed to oil or oilysmoke (cooking areas or machine shops). Oil which adheres to the heat exchangers will cause reduced efficiency, generate mist and may damage plasticcomponents.

■ Avoid exposure to high-frequency waves as this may cause the microprocessorto malfunction.

■ Rated noise levels were derived from tests in an anechoic test room. Noise levels may therefore be greater depending on the surroundings, application,and/or manner of installation.

■ Avoid using air conditioners in rooms with high humidity because excessivecondensation will occur as the air cools.

■ To avoid fire hazards, do not use air conditioners in areas where inflammablegases are present.

■ Odours for buildings, cosmetics, perspiration, cigarette smoke, etc., may accumulate in the heat exchanger and emanate from the air conditioner. This isnot indicative of mechanical trouble.

Obstacle at rear only Service space Top obstacles Obstacles at the right, leftand rear

Obstacles at the front andrear only

Obstacle at the front and rear only

■ Outdoor Unit Installation Location• When installing a single outdoor unit:

• When installing many outdoor units:

PUH-2.5, 3 PUH-4,5,6100mm or more 150mm or more10mm or more 10mm or more500mm or more 500mm or more500mm or moreService space

500mm or more

100mm or more 150mm or more500mm or more 500mm or more10mm or more 10mm or more200mm or more 300mm or more

ABCDEFGHI

PUH-2.5, 3 PUH-4,5,610mm or more 10mm or moreObstruction width: 1.5 times the width ofoutdoor unit or smallerObstruction height: Unit height or lowerAir outlet guide500mm or more 500mm or more100mm or more 150mm or more3000mm or more 3800mm or more100mm or more 150mm or more

J

K

LMNOPQ

Face-to-face arrangement (with air outlet guides)

Face-to-face arrangement (without air outlet guides)

Parallel arrangement (with air outlet guides)

Parallel arrangement (without air outlet guides)

Side-by-side arrangement

10mm or more 10mm or more200mm or more 300mm or moreUp to 10 units (When the optional air outletguides are used, no more than five units shouldbe arranged side by side.)1000mm or more 1000mm or more

PUH-2.5, 3 PUH-4,5,6200mm or more 300mm or more500mm or more 500mm or more200mm or more 300mm or more1200mm or more 1500mm or more1000mm or more 1500mm or more2000mm or more 2500mm or more100mm or more 150mm or more

ABCDEFGHI

J

K

Precautions/recommendations concerning the installation and operation of Mitsubishi Electric Mr. Slim air conditioners.

HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

Mitsubishi Electric Shizuoka Works acquired ISO9001 certification under Series 9000 of theInternational Standard Organization (ISO) based ona review of Quality warranties for the production ofrefrigeration and air conditioning equipment.

Mitsubishi Electric Shizuoka Works acquired envi-ronmental management system standard ISO14001 certification.

Certificate Number EC97J1132Certificate Number 49385

L-179-0-C3085-F SI-0608 Printed in Japan(NLP)

NATIONALACCREDITATION

OF CERTIFICATIONBOOISISO 9001

BLACK DIAMOND TECHNOLOGIES

Wellington:1 Parliament StreetPo Box 30-772Lower HuttWellingtonPh: (04) 560 9147Fax: (04) 560 9133

Auckland:Unit 1, 4 Walls RoadPo Box 12-726, PenrosePh: (09) 526 9347Fax: (09) 526 9369

Christchurch:Suite 2, Level 1, 37 Mandeville StreetPo Box 1604Ph: (03) 341 2837Fax: (03) 341 2838

www.bdt.co.nzMITSUBISHI ELECTRIC AUSTRALIA PTY LTD.

New South Wales:348 Victoria Road,Rydalmere 2116Ph: (02) 9684 7555Fax: (02) 9898 1043

Victoria/Tasmania:Unit 4, 303 Burwood Highway,East Burwood 3151Ph: (03) 9262 9855

Fax: (03) 9262 9844

QueenslandUnit 12, 469 Nudgee Rd.,Hendra 4011Ph: (07) 3623 2000

Fax: (07) 3630 1888

South Australia/Northern Territory:77 Port Road,Hindmarsh 5007Ph: (08) 8340 2000Fax: (08) 8340 0555

Western Australia:Unit 5, 329 Collier Road,Bassendean 6054Ph: (08) 9377 3400Fax: (08) 9377 3499

Far North Queensland:Capricorn Air, 13 Mackley st,Garbutt 4814Ph: (07) 4775 5222

Fax: (07) 4775 5305

www.mitsubishielectric.com.au (Incorporated in New South Wales)ABN 58 001 215 792

Revised publication, effective August 2006Superseding publication of L-179-0-C3085-E November 2005

Specifications subject to change without notice.